Loading...
HomeMy WebLinkAboutPermit S07-047 - AT&TAT & T 387 STRANDER BLVD S07-047 City (*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 387 STRANDER BL TUKW Suite No: PERMANENT SIGN PERMIT Permit Number: S07-047 Issue Date: 08/29/2007 Permit Expires On: 02/25/2008 Business: Name: AT&T Phone: 206-575-4507 Address: 387 STRANDER BLVD , TUKWILA WA Property Owner: Name: REGENCY CENTERS LP Phone: Address: C/O PROPERTY TAX DEPT Contact Person: Name: STEVE ZAMBERLIN Phone: 206-22-0700 Address: 1255 WESTLAKE AVE N Contractor: Name: NATIONAL SIGN CORPORATION Phone: 206-282-0700 Address: 1255 WESTLAKE AVE N DESCRIPTION OF WORK: REPLACE CINCULAR WALL SIGNS WITH 2 AT&T WALL SIGNS. RESUBMITTED PLANS 8/22 TO REVISE APPLICATION AND REMOVE OVAL BACKER FROM SIGN IN ORDER TO CONFORM WITH SIZE REQUIREMENTS. REQURES ELECTRICAL PERMIT. SM Fees Collected: $240.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 406 508 0 0 Wall Sign Size (sq. feet): 14.72 14.72 0 0 Sign Lighting: Face Residential Land: N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 0 Building Height (feet): 0 0 Sign Size (sq. feet): 0 0 Sign Height (feet and inches): 0 ' 0 " 0 ' 0 " Setback (feet): 0 0 Number of Sign Faces: 0 0 Planning Division Authorized Signature: Date: 501\ 67 I hereby certify that I have read and examined thi - - mit and know t same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S07-047 Printed: SITE INSPECTION (PLANNING) File No. S07-047 Name of Tenant: AT&T Sign Address: 387 Strander Blvd Date Photo Taken: October 23, 2007 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of 8/10/2007 Make new site visit and take photo by 02/10/2008 Comments: Inspected 10-23-2007 and fmal approval granted. Stacy MacGregor IR1: removcrbackground panels and chg letters to white, per pc. 8.17.07 kendra at&t RECEIVED AUG 2 2 2007 COMMUNITY DEVELOPMENT #SBWA5782 SOUTHCENTER PLAZA SHOPPING CENTER 387 STRANDER BLVD, STE 1 TUKWILA, WA 98188 -S4:: S-1.46thr-S •MajpPoint' -48th-St 5pthl-St S =1: OthS 405 ,J> r�* .1111 r : 47387Strander,-IBlvd Ste 1 iTukuila,f _ Aa9818812916 Renton I S 166th -St --I [MdVal,, , ti � rrldeI Micken it itHetgs � hltW I Xy a 174 Std 11 5,�182nd ®2O.O5 Miarosof Corp €20�1AIf�Q, and forieAtlas ,Inc. 52 S 34t I-�t ce GJ -10 SW'41 sI St --i 0 Dent ai Sill) �igntech u4 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527.61001 Fax: (619) 5276111 www.signtechUSA.com wsA � 1444 at&t #SBWA5782 Southcenter Plaza Shopping Center 387 Strander Blvd, Ste 1 Tukwila, WA 98188 Date 06/26/07 Salesperson. Arthur Navarro Coordinator Gladys Olaya Designerkendra pickett Scale- As Noted Revisions A -E719 A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBIUTY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whore or in part, without their prior written approval. Drawing Number: 07-01449', Sheet: 1 Of : 8 R1 R1: remove/background panels and chg letters to white, per pc. 8.17.07 kendra - SITE PLAN N.T.S. Strander Blvd Recommendations Report Site Number: SBWA5782 Zone Sign# Sign Type Description Exterior 001 Custom Custom 22.4" channel letters with raceway. 002 Custom Custom 22.4" channel letters with raceway. 003 V-1 Window Vinyl - Store Hours - White Letters - 3.8" Globe - 0.43x 004 INT -PL -1 23" Horizontal Black Non-Illum Dimensional Letters - 23" h x 51.25" w - 0.43x - 6.27sf JL �igntechM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com ISS®A 1115111111110114101111 at&t #SBWA5782 Southcenter Plaza Shopping Center 387 Strander Blvd, Ste 1 Tukwila, WA 98188 Date• 06/26/07 Salesperson Arthur Navarro Coordinator Gladys Olaya Designer. kendra Pickett Scale. As Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date Tliis design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 07-01449 Sheet 2 Of: 8 R1 R1: removobackground panels and chg letters to E001 SIGNAGE 15'-8%" 12'-93/4" 9'-8" Eq EXISTING STOREFRONT ELEVATION SCALE: 3/32"=1'-0" PATCH AND REPAIR EXISTING WALL SURFACE TO LIKE NEW CONDITION. REPAINT TO MATCH EXISTING WALL COLOR FINISH. FOR BRICK OR STONE WALLS FILL HOLES WITH MATCHING SILICONE. POWER WASH WALL IF REQUIRED. INSTALL NEW SIGNAGE USING EXISTING PRIMARY ELECTRICAL. VERIFY IF ADDITIONAL CIRCUITS ARE REQUIRED FOR NEW SIGN. EXISTING WALL PAINT COLOR: TBD E002 EXISTING REAR OF STORE ELEVATION EXISTING WALL PAINT COLOR: TBD SCALE: 3/32"=11-0" PROPOSED SIGNAGE 001 PROPOSED STOREFRONT ELEVATION SCALE: 3/32"=1'-0" 051 erf:L.1 002 PROPOSED REAR OF STORE ELEVATION EXISTING WALL PAINT COLOR: TBD :SCALE: 3/32"=1'-0" �igntechTM 4444 Federal Phone: (619) www.signtechUSA.com Blvd. San Diego CA 92102 527-6100 / Fax: (619) 527-6111 MEMBER at&t #SBWA5782 Southcenter Plaza Shopping Center 387 Strander Blvd, Ste 1 Tukwila, WA 98188 Date• 06/26/07 Salesperson. Coordinator Designerkendrapickett Arthur Navarro Gladys Olaya Scale- As Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILI7Y OF OTHERS! Customer Signature Date This design is the exclusive roperty of Signtech and cannot be reproducedlin whole or in part, without their prior written approval. Drawing Number: 07-01449 Sheet: 4 Of : 8 R1 2'-6" CUSTOM CUSTOM RACEWAY ON SUPPORT STRUCTURE SCALE: 3/a"=1'-0" SQ FT: 19.92 /01 2 1/8" MANUFACTURE AND INSTALL ONE (1) INTERNALLY ILLUMINATED SET OF CHANNEL LETTERS AND LOGOS WITH RACEWAY GLOBE LOGO: 5"DEEP FACE: .118" CLEAR SG THERMOFORMED ACRYLIC (ACRYSTEEL OR APPROVED EQ)SECOND SURFACE DECORATE WITH VINYL AS SHOWN IN VINYL DETAIL WITH .125" ALUM. RETAINER PAINTED #41-342 BRUSHED ALUMINUM SATIN FINISH. RETURNS: .050" THICK ALUMINUM PAINTED MATTHEWS #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. BACKS: TO BE .063" THICK ALUM PAINTED #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. AT&T: 5" DEEP FACES: .177" WHITE TRANSLUCENT ACRYLIC #2447 AND 1" JEWELITE SILVER METALLIC TRIMCAP. RETURNS: .050" THICK ALUMINUM PAINTED MATTHEWS #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. BACKS: TO BE .063" THICK ALUM PAINTED #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. ILLUMINATION: LED LIGHT SOURCE BY G.E. GELCORE AS REQUIRED FOR PROPER EVEN ILLUMINATION RACEWAY: .063" ALUM. FABRICATION, PAINTED TO MATCH EXISTING BUILDING. END VIEW 3M #3635-30 WHITE DIFFUSER FILM SECOND. SURFACE .118" CLEAR SG THERMO- t j FORMED ACRYLIC DOME 1 1 ,j) 1111111111111111.11111111110 I' tJ 3M FILM #3630-8015 - — _ - - DARK BLUE SECOND SURFACE 3M #3630-8071 LIGHT BLUE SECOND SURFACE LOGO COLOR VINYL DETAIL .118" THERMOFORMED 3M #3635-30 CLEAR ACRYLIC FACE WHITE DIFFUSER FILM 7_ SECOND SURFACE 3M FILM #3630-8015 DARK BLUE SECOND SURFACE 3M #3630-8071 LIGHT BLUE SECOND SURFACE OLOGO VINYL APPLICATION SCALE: 1 '/2"=1'-0" NOTE: The gauge of the wire is dictated by the length of the run & amperage as per NEC Article 300. - The ground wire must be continuous & go from the sign to the panelboard ground bus. - Voltage between ground and neutral should measure no more than 3 volts. - Power to the sign must be done by a licensed electrical contractor or licensed electrician. 1 I / 1 1 / I �igntechTM 4444 Federal Phone: (619) www.signtechUSA.com Blvd. San Diego CA 92102 52741001 Fax: (619) 527-6111 SQA O ERZWINISICMIMI 4...d1 at&t #SBWA5782 Southcenter Plaza Shopping Center 387 Strander Blvd, Ste 1 Tukwila, WA 98188 Date* 06/26/07 Salesperson Coordinator Designer Arthur Navarro Gladys Olaya kendra pickett Scale. As Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusiveproperty of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 07-01449 Sheet: 5 Of : 8 R1 /4 1 \ i .050" ALUM. SYMBOL RETURN TO MATCH SILVER MATTHEWS 41-342 BRUSH ALUMINUM. .125" ALUM. CAM CUT RING RETAINER WELDED TO .080" ALUM. FLAT STOCK. i PAINTED TO MATCH SILVER MATTHEWS 41-342, BRUSH ALUMINUM. / "GLOBE" .118" SG THERMOFORMED ACRYLIC (ACRYLSTEEL OR APPROVED EQ.) SECOND SURFACE DECORATE PER CALL OUTS. /� ALUMINUM FABRICATED RACEWAY DISCONNECT SWITCH WITHIN SITE OF SIGN POWER UNIT BY GELCORE (GECLPS5) TETRA POWER WHITE LED STRIP BY GELCORE (GEWHPTS3-65K) #8 STAINLESS STEEL COUNTERSUNK SCREW TO ATTACH RETAINER TO CABINET (TYP.) WEEP HOLES WITH LIGHT SCREENS. AS REQUIRED. 5 /' WEEP HOLE , VERTICAL SECTION @ SYMBOL Scale: 3"=1'-0" 0 —J U w RETURN THICKNESS TO BE .050" ALUMINUM PAINT EXTERIOR SURFACE TO MATCH SILVER MATTHEWS'41-342, BRUSH ALUMINUM. PAINT INTERIOR SURFACE WITH SPRAY -LAT STAR BRITE LIGHT ENHANCEMENT PAINT. TRIM CAP 1° JEWELITE SILVER METALLIC. LEITER FACE TO BE .177" WHITE TRANSLUCENT ACRYLIC #2447 LETTERS BACK TO BE .063" ALUM. PAINT EXTERIOR SURFACE TO MATCH SILVER MATTHEWS 41-342, BRUSH ALUMINUM. PAINT INTERIOR SURFACE WITH SPRAY -LAT STAR BRITE LIGHT ENHANCEMENT PAINT. DISCONNECT SWITCH WITHIN SITE OF SIGN .063" ALUM. FABRICATED RACEWAY WITH INTERNAL ALUM. ALUM. ANGLE FRAME AS REQUIRED. WEEP HOLES WITH LIGHT SCREENS. AS REQUIRED. VERIFY ATTACHMENTS 5// •U VERTICAL SECTION (BLACK LETTERS) Scale: 3"=1'-0" 0 J / i / 1 / �igntech 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-6100 ! Fax: (619) 527-6111 www.signtechUSA.com 1030381 ISA ®nnto1131om. DEMMER OF at&t #SBWA5782 Southcenter Plaza Shopping Center 387 Strander Blvd, Ste 1 Tukwila, WA 98188 Date- 06/26/07 Salesperson -Arthur Navarro Coordinator Gladys Olaya Designer kendra pickett Scale- As Noted A A A A A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 07-01449 Sheet: 6 Of: 8 R1 Southcenter Plaza Iregellgrcenters 395 Strander Blvd. Tukwila, Washington 98188 carr~ cllnnnner�v ()TARGET ❑Available II Anchor ❑Leased ❑N.A.P. (Not A Part) Target 111,900 SQ. FT. 1 Busy Body 3,501 SQ. FT. 2 Maytag 6,000 SQ. FT. • r A Kim's Mongolian Grill 2,450 SQ. FT. B Washington Mutual 3,000 SQ. FT., C Boater's World Discount 8,040 SQ. FT. D Mizu Steakhouse and Sushi Bar 4,713 SQ. FT. F Verizon Wireless 1,750 SQ. FT. G Tulip's Nail Salon 1,750 SQ. FT. H Zoopa Restaurant 8,015 SQ. FT. I Cingular Wireless 1,500 SQ. FT. Quizno's 1,300 SQ. FT. K Supercuts 1,300 SQ. FT. L Available 1„078 SQ. FT.'; M Sleep Country USA 3,610 SQ. FT. N Simply Thai 1,600 SQ. FT. 0 Starbucks Coffee 1,194 SQ. FT. P International Jewelers 4,500 SQ. FT. Q Burger King 2,980 SQ. FT. STRANDER BOULEVARD This site plan is presented solely for the purpose of identifying the approximate location and size of the building presently contemplated by the owner. Building sizes, site dimensions, access and parking areas. existing tenant locations and identities are subject to change without notice and at the owners discretion. Unit numbers as indicated are not necessarily the actual suite numbers and are intended for use as a reference only. Portland Office 503.603.4700 800.465.4558 regencycenters.com National Reach. Local Expertise. QUALITY SHOPPING CENTERS DCD-Intrn Intern - AT&T -Tukwila, WA •WA5782 Pagel From: Rhonda Mix <rhonda@signtechUSA.com> To: Stacy <smacgregor@ci.tukwila.wa.us.> Date: 08/13/2007 10:06 am Subject: AT&T -Tukwila, WA #SBWA5782 CC: Gladys Olaya <golaya@signtechUSA.com> Attached: 444521 - SBWA5782_Site Plan & Sq Ft.pdf Stacy: I spoke with you a few weeks ago regarding the sign permit for the subject location. Per your request I am attaching the site plan and square footage of the suite involved. Should you have any questions please direct them to Gladys as I am leaving the company on Thursday. Thank you for your consideration. Rhonda Mix Signtech Electrical Advertising Direct 619-398-1620 Fax 866-343-2795 P\roN7\o... 811y cam bo cas.�0 S� f Gnus � �rnv�Ston.J -� � CCW--,��u9Q� Q ScvSSe-� '�c-- $� W� off- July 18, 2007 Steve Zamberlin National Sign Corporation 1255 Westlake Ave N Seattle, WA 98109 RE: AT&T (Permit #S07-047) Dear Mr. Zamberlin: This letter is in regards to your sign permit application for the new AT&T sign to replace Cingular Wireless signage on Strander Boulevard in Tukwila. As proposed, your application does not meet the City Of Tukwila sign code (TMC 19.32.140). The size of the proposed signs exceeds the allowed size for wall -mounted signs. In calculating the size of the sign, the white oval backer is considered part of the sign and included in the measurements, totaling 35.6 sf. With the backer removed, the signs at 16.2 sf, would meet our code. From the information provided, I cannot accurately calculate the actual exposed building face of the building where this sign will be located. To illustrate your options, I am estimating a range between 350 and 508 sf which gives you allowable signage between 17.6 and 25.32 sf. City of Tukwila sign code (TMC 19.32.150) will allow you to apply for an increase in the allowable sign area of up to 50% for each doubling of the required setback. Setbacks were not included in the plans you submitted but it appears from the plans that this will be an option on the west side of the building only. A 15 foot setback is required in the Tukwila Urban Center where this site is located. However, this increase is limited to 6% of the exposed building face on which the sign is placed. I will need additional information to calculate the exact building face but using the above exposed building faces you would be allowed signage between 21 and 30.5 sf which means that the signs, as proposed, are still too large. Please amend your application to reflect these considerations. I am including with this letter an application for a Type II decision to increase the allowable sign area for increased setbacks. If you have any questions, please call (206) 433-7166 or send an email to smacgregor@ci.tukwila.wa.us.. Sincerely, Stacy Mac l egor Planning Intern cc. File (S07-047) Enclosure Emailed copy to stevez@nationalsigncorp.com CAP, of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206 431-3670 PERMIT NCOo1 — 7RECEIVE® JULI17 2007, MMUNITy ELOPAQENT 575 Ko7 one 2d4J JZ 0700 one 61 Zf2- 0700 P one/ 3S / I.3 t 2 60/12. fisc Ap lt/Contact ddress, Ci `State, i siE�4��4Ii�/–A, rBusAddress o flhL lof � C� fuf Contractor Address, City, State, Zip 9 0~ 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $120 application fee per sign See back of form for examples Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Wall No Did building go through design review? 0 Yes 1 WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) 4 66 q ft, 501.01 , Sign size(square feet) • 1, Vie.. 33 ¢ .; 7g• 3 Does sign face residential zones or public facilities? Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones: / '_v/ f �J N\e\l'.. r Does wall sign weigh more than 400 pounds?(Y/N) /‘% Sign illumination (internal/external/none) Ieft/1 VM„ 1 4L. FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of si • n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. . It is the responsibility of the installer to obtain the elec cal per. it and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLIC. % VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnishe the applicable requirements of the City of Tukwila will b Date 7-17-'1 TION by me met. true an• correct under penalty of perjury by law in the State of Washington, and that (Signat f e •f orf er •r authorized agent) Email Address Zoning: lanning review by: O Denied O Issued ❑ Issued with conditions Structural review required? 0 Yes ❑ No Structural review by: O Denied P:\Planning Forms\ Applications \PermSign-12-06.doc on 12/20/01 O Approved 0 Approved with conditions Revised