Loading...
HomeMy WebLinkAboutPermit S07-070 - DRESS BARNDRESS BARN 17250 SOUThCETNER PY 507-070 ''of t ukwila' Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 2623049117 Address: 17250 SOUTHCENTER PY TUKW Suite No: Permit Number: Issue Date: Permit Expires On: S07-070 09/25/2007 03/23/2008 Business: Name: Address: Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: DRESS BARN 17250 SOUTHCENTER PY SUITE 130 , Phone: WIG PROPERTIES LLC -SS Phone: 4811 134TH PL SE HAROLD AT SIGN TECH Phone: 253-922-2146 SIGN -TECH ELECTRIC INC 5113 PACIFIC HWY E #12 Phone: 253-922-2146 DESCRIPTION OF WORK: ONE WALL SIGN FOR DRESS BARN. sm Fees Collected: PERMANENT SIGN: Wall Area (sq. feet): Wall Sign Size (sq. feet): Sign Lighting: Face Residential Land: $120.00 Zoning: TUC Sign Type: Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Wall Sign #1 2534 79.7 N Wall Sign #2 0 0 Freestanding Sign #1 0 0 0 0' 0" 0 0 Wall Sign #3 0 0 Freestanding Sign #2 0 0 0 0' 0" 0 0 Wall Sign # 0 0 Planning Division Authorized Signature Date: 9 12 1p f 07 I hereby certify that I have read and examined t = t and know the ame to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S07-070 Printed: SITE INSPECTION (PLANNING) File No. S07-070 Name of Tenant: DRESSBARN Sign Address: 17250 Southcenter Py Date Photo Taken: October 17, 2007 Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of 8/10/2007 Make new site visit and take photo by 02/10/2008 Comments: Inspected 10-17-07 and final approval granted. Stacy MacGregor A • • .,. • FRONT ELEVATION CHANNEL LETTERS (80.64 SQ FT) ALLOWED SQ FT= 65+79.56 QUANTITY REQUIRED: (1) One Set this elevation 2" red trim cap Pre -finished black .040 aluminum sides Side view 4- 5' 2" 37'-0" NOTE: COLORS AND PHOTOGRAPHIC REPRESENTATIONS ON THIS DRAWING ARE FOR VISUAL MD ONLY. EXACT COLORS SHOULD BE OBTAINED THROUGH COLOR SWATCHES SUPPLIED UPON REQUEST. 25'-2" Letters 5'2" I: i+1DRES CV in Individual channel letters. Faces: 3/18" red acrylic #2414 2" red trim cap side returns: .040 pre -finished black 1 aluminum sides 5" deep Illuminate using red LED units Partial Front Elevation - scale: NTS .040 mill aluminum backs Typical Detail view scale: 1-1/2"=1'-0" 2" red trim cap 3/16" red acrylic #2415 Red LED units 4" #10 Tech Screws w/ nylon anchors 4-6 per letter weep holes .040 pre -finished black aluminum sides K 77'-10" 3'1 ` M Front Elevation - scale: 3/32"=1' SIGN SPECIFICATIONS TYPE: CHANNEL LETTERS *LETTERS INTERNALLY ILLUMINATED WITH 3 ROWS OF RED LEDs. *FACE COVER CONSTRUCTED OF 3/16" THICK #2415 RED MATERIAL. *FACE COVER SCREW FASTENED TO 2" Red TRIM AROUND EDGE LETTER. *SIDE SKIRT OF RETURN LETTER: 5 INCHES, PRE -FINISHED BLACK ALUMINUM *BACKS: .040 MILL ALUMINUM WITH NUTSERTS AND THREADED ROD *TRANSFORMER REMOTE MOUNTED BEHIND WALL IN METAL VENTED TRANSFORMER BOX. *LETTERS FLUSH MOUNTED TO (VERIFY) WALL SURFACE. AND POSITIONED ON WALL AS INDICATED ON DRAWING. *LETTERS TO BE HOOKED UP TO EXISTING 120 CIRCUIT. LAYDLURD APPROVAL CC ere w w CC R � o 2 CD Z O ag c 0 d ow RC: I DGw i IM IT ill i DRSSBARN �) r� t „� 9i \ LiW _ _ __�_.____- i 26' : z Front Elevation - scale: 3/32"=1' SIGN SPECIFICATIONS TYPE: CHANNEL LETTERS *LETTERS INTERNALLY ILLUMINATED WITH 3 ROWS OF RED LEDs. *FACE COVER CONSTRUCTED OF 3/16" THICK #2415 RED MATERIAL. *FACE COVER SCREW FASTENED TO 2" Red TRIM AROUND EDGE LETTER. *SIDE SKIRT OF RETURN LETTER: 5 INCHES, PRE -FINISHED BLACK ALUMINUM *BACKS: .040 MILL ALUMINUM WITH NUTSERTS AND THREADED ROD *TRANSFORMER REMOTE MOUNTED BEHIND WALL IN METAL VENTED TRANSFORMER BOX. *LETTERS FLUSH MOUNTED TO (VERIFY) WALL SURFACE. AND POSITIONED ON WALL AS INDICATED ON DRAWING. *LETTERS TO BE HOOKED UP TO EXISTING 120 CIRCUIT. LAYDLURD APPROVAL CC ere w w CC R � o 2 CD Z O ag c 0 d ow RC: I DGw i IM IT ill i Nage SS3UG ICennaed JGWe3LIynos Are�iMP911!!Sll�s ' __ 1T ei1II11 '.. 'Iv ., e11ttllF . .,,-ts it ■ 10 =I itill it 11" la wil .ti ;r 114 ledi 164PR Mho Sh ii1111 ..w-lit111 .1elk� Itt air ii of ILI fi. 165 OA i ■1 i't i 1isi .1.11 T I! an `-1 { :zity■ ER 02 111E as 3 1Gr i..'1'Grr .I Mb aaIt k 12or.J izL I $4918F • • • /`GN -T ELECTRIC Rfe Business Park 5113 PotatoEast Suite 12 Hwy Rti3, WA 98424 Pierce: Z53422-2146 Meg: 266-7194020 Fax: 253422.2152 DRESS BARN REVISIONS: Tiffs sign is intandad to be ire in accamnce Fah K�II a, Ai,�r 8OOoftheMstlorodaadrkai t audios Mot appends aoi codas. Thd imdWas propor gtou nding and bonding of the sign. NDT6 h:.ismx4,,,, ya„i� �°d4 T-fi-Oa*��h� .d,Qyas�r� �� ming CUSTOMER 1 LANDLORD APPROVAL • At 17250 Southcenier Parkway SUITE i 3O, TU KW I IA, WA merman with prai.d plarad for you 4 Son Tads e.drie. t is not to be shown to my ono wide you a¢s,imia,, not Se tots odd, mprod„oatcoped a ad,�trd in a' India, My Frosted colors on droninga• fa rapr.mrsdra,, adafud cola for final product n,oy ..ry. PHONE � SIGNATURE DATE Contractors tic. SIGNTEL 9888G DATE: RENAME pmoti...ne s°spooI Sus: RG 6RASKIN:,T Sign -Tech Electric 5113 Pacific Hwy East Suite 12 Fife, WA 98424 Office (253) 922-2146 Fax (253) 922-2152 To: • STE42: 01/30/07 Date .30/02007 Fax: ( ) u Master Electrical License # SIGNTEL988BG Exp. 1/7/2008 ❑ Federal Identification # 91-2149366 ❑ UBI for Sales Tax # 602 152 490 DEPARTMENT: OF LABOR :AND INDUSTRIES LICENSED .AS.:PROVIDED BY LAW AS . ELEC CONTR' ` GENERAL' - LICENSE:; # EXP . DATE EC01-: .,SIGNTEL988BG 01/07/2008' EFFECTIVE DATE 01/07/20025,• T SIGN; TECH ;::ELECTRIC :;LLC.:.. X77 33759.. -NINTH AVENUE. `S FEDERAL. WAY WA 98003': RI:5-05:-0N)isrY7e John Mendenhall Co-Owner/CEO/Administrator Linda Mendenhall Co-Owner/Business Manager Authorized Signatures Subscribed and Sworn to Before Me this Date: 1130/057 Notary Public:-..hki.m.2_ .. eVtOW Residing at:. (QO.S SE. 401 My commission expires: ii/ /9/200 $� PkiAtirtey, 001111111, 4Volrettlet.°S, Zi* _4psti 00,00 0• 0 QV City oS ukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 206 431-3670 PERMIT 30-1-0-76 DATE: '"1 _'1 TUKV/ILA PERMANENT SIGN PERMIT APPLICATION Dr953 Business Name Applicant/Contact 5,1,, -rrc4l Eieek, vc Cont for Please print /72o Sa,�l e.fer �Jrk'way1 '54 e /30 Adss of Sign 57/3 Pae. Aikve 5i,/,`"e141/02 Phi:, i4 Address, City, State,'Zip 51/3P, A,/f/2, �, t�/I 9f <izC/ Address, City, State, Zip Phone ,25-3, 99z2 -2/6/(p Phone 43- 922- z/'/� Phone CHECKLIST ❑ 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs ❑ Sign elevations with area calculations and dimensions ❑ Building elevations (for wall signs) ❑ Supporting structure and method of illumination ❑ One copy of valid Washington State contractor's license ❑ $100 application fee per sign See back of form for examples How many signs will list this business? Freestanding Did building go through design review? ❑ Yes Is your sign a: O Freestanding sign 15 or more feet in height O Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: O $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). O Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION ❑ No Wall__ WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) 3a .- �f Sign size(square feet) %q 7 get F-1 Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. Does wall sign we'. ' ...re than 400 pounds?(Y/N) NO Sign illumination At) external/none) t -ED F : ESTAND ` GNS: #1 #2 Street fro : • • of the entire premises where the sign will one freestanding s . . llowed per premises. be located (feet). Generally, only than the building with which they Height of building (feet). Genera , • es may not be higher are associated Size of sign face (square feet). Structural review is requir- . ., • ole •• ith faces 30 square feet or more in area Sign height (feet -inches). Structural review . wired for signs 15 feet or more in ;• . t. Generally, signs must be set back Distance from closest edge . n to property lines (feet). from all property lines ante equal to their height. Numb aces If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. . structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Jivision at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila w• Date Zoning: (Signature of o authorized agent) FOR'OFFICE-USEONLY, Planning review by: __ 0 Denied 0 Issued as3 -yzz- Z76 Phone 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: 0 Denied 0 Approved 0 Approved with conditions