HomeMy WebLinkAboutPermit S07-070 - DRESS BARNDRESS BARN
17250 SOUThCETNER PY
507-070
''of t ukwila'
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
PERMANENT SIGN PERMIT
Parcel No.: 2623049117
Address: 17250 SOUTHCENTER PY TUKW
Suite No:
Permit Number:
Issue Date:
Permit Expires On:
S07-070
09/25/2007
03/23/2008
Business:
Name:
Address:
Property Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
DRESS BARN
17250 SOUTHCENTER PY SUITE 130 ,
Phone:
WIG PROPERTIES LLC -SS Phone:
4811 134TH PL SE
HAROLD AT SIGN TECH Phone: 253-922-2146
SIGN -TECH ELECTRIC INC
5113 PACIFIC HWY E #12
Phone: 253-922-2146
DESCRIPTION OF WORK:
ONE WALL SIGN FOR DRESS BARN. sm
Fees Collected:
PERMANENT SIGN:
Wall Area (sq. feet):
Wall Sign Size (sq. feet):
Sign Lighting:
Face Residential Land:
$120.00 Zoning: TUC Sign Type:
Street Frontage for Entire Lot:
Building Height (feet):
Sign Size (sq. feet):
Sign Height (feet and inches):
Setback (feet):
Number of Sign Faces:
Wall Sign #1
2534
79.7
N
Wall Sign #2
0
0
Freestanding Sign #1
0
0
0
0' 0"
0
0
Wall Sign #3
0
0
Freestanding Sign #2
0
0
0
0' 0"
0
0
Wall Sign #
0
0
Planning Division Authorized Signature
Date: 9 12 1p f 07
I hereby certify that I have read and examined t = t and know the ame to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
doc: SIGN -PERM S07-070 Printed:
SITE INSPECTION (PLANNING)
File No. S07-070
Name of Tenant: DRESSBARN
Sign Address: 17250 Southcenter Py
Date Photo Taken: October 17, 2007
Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of 8/10/2007
Make new site visit and take photo by 02/10/2008
Comments: Inspected 10-17-07 and final approval granted. Stacy MacGregor
A
• • .,. •
FRONT ELEVATION
CHANNEL LETTERS (80.64 SQ FT) ALLOWED SQ FT= 65+79.56
QUANTITY REQUIRED: (1) One Set this elevation
2" red trim
cap
Pre -finished black
.040 aluminum
sides
Side view
4- 5' 2"
37'-0"
NOTE: COLORS AND PHOTOGRAPHIC REPRESENTATIONS ON THIS
DRAWING ARE FOR VISUAL MD ONLY. EXACT COLORS SHOULD BE
OBTAINED THROUGH COLOR SWATCHES SUPPLIED UPON REQUEST.
25'-2" Letters
5'2" I:
i+1DRES
CV
in
Individual channel letters.
Faces: 3/18" red acrylic #2414
2" red trim cap
side returns: .040 pre -finished black
1
aluminum sides 5" deep
Illuminate using red LED units
Partial Front Elevation - scale: NTS
.040 mill aluminum
backs
Typical Detail view
scale: 1-1/2"=1'-0"
2" red trim cap
3/16" red acrylic
#2415
Red LED units
4" #10 Tech Screws
w/ nylon anchors
4-6 per letter
weep holes
.040 pre -finished black
aluminum sides
K
77'-10"
3'1 `
M
Front Elevation - scale: 3/32"=1'
SIGN SPECIFICATIONS
TYPE:
CHANNEL LETTERS
*LETTERS INTERNALLY ILLUMINATED WITH
3 ROWS OF RED LEDs.
*FACE COVER CONSTRUCTED OF 3/16" THICK
#2415 RED MATERIAL.
*FACE COVER SCREW FASTENED TO 2" Red TRIM
AROUND EDGE LETTER.
*SIDE SKIRT OF RETURN LETTER: 5 INCHES,
PRE -FINISHED BLACK ALUMINUM
*BACKS: .040 MILL ALUMINUM WITH NUTSERTS
AND THREADED ROD
*TRANSFORMER REMOTE MOUNTED BEHIND WALL
IN METAL VENTED TRANSFORMER BOX.
*LETTERS FLUSH MOUNTED TO (VERIFY) WALL SURFACE.
AND POSITIONED ON WALL AS INDICATED ON DRAWING.
*LETTERS TO BE HOOKED UP TO EXISTING 120
CIRCUIT.
LAYDLURD APPROVAL
CC
ere
w
w
CC R
� o
2
CD
Z
O
ag
c
0 d
ow
RC: I DGw i IM IT
ill
i
DRSSBARN
�)
r� t „� 9i
\ LiW
_ _ __�_.____-
i
26'
:
z
Front Elevation - scale: 3/32"=1'
SIGN SPECIFICATIONS
TYPE:
CHANNEL LETTERS
*LETTERS INTERNALLY ILLUMINATED WITH
3 ROWS OF RED LEDs.
*FACE COVER CONSTRUCTED OF 3/16" THICK
#2415 RED MATERIAL.
*FACE COVER SCREW FASTENED TO 2" Red TRIM
AROUND EDGE LETTER.
*SIDE SKIRT OF RETURN LETTER: 5 INCHES,
PRE -FINISHED BLACK ALUMINUM
*BACKS: .040 MILL ALUMINUM WITH NUTSERTS
AND THREADED ROD
*TRANSFORMER REMOTE MOUNTED BEHIND WALL
IN METAL VENTED TRANSFORMER BOX.
*LETTERS FLUSH MOUNTED TO (VERIFY) WALL SURFACE.
AND POSITIONED ON WALL AS INDICATED ON DRAWING.
*LETTERS TO BE HOOKED UP TO EXISTING 120
CIRCUIT.
LAYDLURD APPROVAL
CC
ere
w
w
CC R
� o
2
CD
Z
O
ag
c
0 d
ow
RC: I DGw i IM IT
ill
i
Nage SS3UG
ICennaed JGWe3LIynos
Are�iMP911!!Sll�s ' __
1T ei1II11 '..
'Iv ., e11ttllF .
.,,-ts
it
■ 10
=I itill
it 11"
la
wil
.ti
;r
114
ledi
164PR
Mho
Sh ii1111
..w-lit111 .1elk�
Itt
air
ii
of
ILI
fi. 165
OA
i ■1
i't
i 1isi .1.11
T I!
an
`-1
{ :zity■
ER 02
111E
as
3
1Gr i..'1'Grr .I
Mb aaIt k
12or.J
izL
I $4918F
•
•
•
/`GN -T
ELECTRIC
Rfe Business Park
5113 PotatoEast Suite 12
Hwy
Rti3, WA 98424
Pierce: Z53422-2146 Meg: 266-7194020 Fax: 253422.2152
DRESS BARN
REVISIONS:
Tiffs sign is intandad to be
ire in accamnce Fah
K�II a, Ai,�r
8OOoftheMstlorodaadrkai
t audios Mot appends
aoi codas. Thd imdWas
propor gtou nding and
bonding of the sign.
NDT6 h:.ismx4,,,, ya„i�
�°d4 T-fi-Oa*��h�
.d,Qyas�r� ��
ming
CUSTOMER 1 LANDLORD APPROVAL
•
At
17250 Southcenier Parkway
SUITE i 3O, TU KW I IA, WA
merman with prai.d
plarad for you 4 Son Tads
e.drie. t is not to be shown to my
ono wide you a¢s,imia,, not
Se tots odd, mprod„oatcoped
a ad,�trd in a' India, My
Frosted colors on droninga• fa
rapr.mrsdra,, adafud cola for
final product n,oy ..ry.
PHONE
�
SIGNATURE
DATE
Contractors tic.
SIGNTEL 9888G
DATE:
RENAME pmoti...ne s°spooI Sus:
RG
6RASKIN:,T
Sign -Tech Electric
5113 Pacific Hwy East
Suite 12
Fife, WA 98424
Office (253) 922-2146 Fax (253) 922-2152
To:
•
STE42: 01/30/07
Date .30/02007
Fax: ( )
u Master Electrical License # SIGNTEL988BG Exp. 1/7/2008
❑ Federal Identification # 91-2149366
❑ UBI for Sales Tax # 602 152 490
DEPARTMENT: OF LABOR :AND INDUSTRIES
LICENSED .AS.:PROVIDED BY LAW AS
.
ELEC CONTR' ` GENERAL' -
LICENSE:; # EXP . DATE
EC01-: .,SIGNTEL988BG 01/07/2008'
EFFECTIVE DATE 01/07/20025,•
T
SIGN; TECH ;::ELECTRIC :;LLC.:.. X77
33759.. -NINTH AVENUE. `S
FEDERAL. WAY WA 98003':
RI:5-05:-0N)isrY7e
John Mendenhall
Co-Owner/CEO/Administrator
Linda Mendenhall
Co-Owner/Business Manager
Authorized Signatures
Subscribed and Sworn to Before Me this Date: 1130/057
Notary Public:-..hki.m.2_ .. eVtOW
Residing at:. (QO.S SE. 401
My commission expires: ii/
/9/200 $�
PkiAtirtey,
001111111,
4Volrettlet.°S,
Zi* _4psti
00,00
0• 0 QV
City oS ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100
Tukwila, Washington 98188
206 431-3670
PERMIT 30-1-0-76
DATE: '"1 _'1
TUKV/ILA
PERMANENT SIGN PERMIT APPLICATION
Dr953
Business Name
Applicant/Contact
5,1,, -rrc4l Eieek, vc
Cont for
Please print
/72o Sa,�l e.fer �Jrk'way1 '54 e /30
Adss of Sign
57/3 Pae. Aikve 5i,/,`"e141/02 Phi:, i4
Address, City, State,'Zip
51/3P, A,/f/2, �, t�/I 9f <izC/
Address, City, State, Zip
Phone
,25-3, 99z2 -2/6/(p
Phone
43- 922- z/'/�
Phone
CHECKLIST
❑
3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
❑ Sign elevations with area calculations and
dimensions
❑ Building elevations (for wall signs)
❑ Supporting structure and method of illumination
❑ One copy of valid Washington State contractor's license
❑ $100 application fee per sign
See back of form for examples
How many signs will list this business? Freestanding
Did building go through design review? ❑ Yes
Is your sign a:
O Freestanding sign 15 or more feet in height
O Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
If any of the above are true, the application must go through
structural review.
STRUCTURAL REVIEW CHECKLIST:
O $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
O Construction details to describe the proposed foundation
or wall attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
❑ No
Wall__
WALL SIGNS:
#1
#2
#3
#4
Wall area (length x height) where the sign will be
mounted? (square feet) 3a
.- �f
Sign size(square feet) %q 7
get F-1
Does sign face residential zones or public facilities?
(Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
Does wall sign we'. ' ...re than 400 pounds?(Y/N)
NO
Sign illumination At) external/none)
t -ED
F : ESTAND ` GNS:
#1
#2
Street fro : • • of the entire premises where the sign will
one freestanding s . . llowed per premises.
be located (feet). Generally, only
than the building with which they
Height of building (feet). Genera , • es may not be higher
are associated
Size of sign face (square feet). Structural review is requir- . ., • ole •• ith faces 30
square feet or more in area
Sign height (feet -inches). Structural review . wired for
signs 15 feet or more in ;• . t.
Generally, signs must be set back
Distance from closest edge . n to property lines (feet).
from all property lines ante equal to their height.
Numb aces
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
. structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Jivision at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and
that the applicable requirements of the City of Tukwila w•
Date
Zoning:
(Signature of o
authorized agent)
FOR'OFFICE-USEONLY,
Planning review by: __
0 Denied 0 Issued
as3 -yzz- Z76
Phone
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
0 Denied 0 Approved 0 Approved with conditions