Loading...
HomeMy WebLinkAboutPermit S07-080 - CALIFORNIA PIZZA KITCHENCALIFORNIA PIZZA KITCHEN 150 ANDOVER PK W S07-080 City clIPTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 0223100010 Address: 150 ANDOVER PK W TUKW Suite No: PERMANENT SIGN PERMIT Permit Number: S07-080 Issue Date: 11/09/2007 Permit Expires On: 05/07/2008 Business: Name: CALIFORNIA PIZZA KITCHEN Phone: Address: 150 ANDOVER PK W , TUKWILA WA Property Owner: Name: OPEN FRAME LLC Phone: Address: 2635 CARILLON PT Contact Person: Name: SHAWN BOWEN Phone: 206-223-1122 Address: Contractor: Name: TUBE ART DISPLAYS Phone: 206-223-1122 Address: 1705 4TH AVE S DESCRIPTION OF WORK: 2 WALL SIGNS FOR CALIFORNIA PIZZA KITCHEN Fees Collected: $240.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 759.5 691 0 0 Wall Sign Size (sq. feet): 15.94 31.55 0 0 Sign Lighting: Face Residential Land: N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 0 Building Height (feet): 0 0 Sign Size (sq. feet): 0 0 Sign Height (feet and inches): 0 ' 0 " 0 ' 0 " Setback (feet): 0 0 Number of Sign Faces: 0 0 Planning Division Authorized Signature: \c,c, Date: I' ~ t —07 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S07-080 Printed: SITE INSPECTION (PLANNING) File No. S07-080 Name of Tenant: California Pizza Kitchen Sign Address: 150 Andover PK W Date Photo Taken: February 26, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of 10/23/2007 Make new site visit and take photo by 03/25/2008 Comments: Sign inspected and meets code. C13 2-27-08 3\$s:2 N rn 6' - 4 1/2" 6'-23/4° PERF ALUMINUM RETURNS w/ WHITE LEXAN BACK w/1st SURFACE ARLON YELLOW (2500-525) VINYL 14°I 8° III 1 1/2° FRONT VIEW 151/4" 13" 12 3/4° RIBBON CABINET DIAMOND CABINET END VIEW 1-MCiiWte4T 5'. t/44 LAA5 IN'i0 o Y -foci S/F INTERNALLY ILLUMINATED WALL SIGN w/ MULTIPLE LAYERS SQ. FT. = 31.87 SCALE: 3/8° = 1' - 0" GENERAL SPECIFICATIONS DIAMOND CABINET: 8" DEEP FACE & HALO LIT CHANNEL w/ ILLUMINATED RETURNS. • RETURN -ALUMINUM PERFORATED RETURNS PAINTED BLACK w/ WHITE LEXAN BACKING w/ 1st SURFACEARLON YELLOW (2500-525) VINYL • FACE - #7328 WHITE ACRYLIC w/ 1st SURFACE VINYL GRAPHICS; OUTLINES - BLACK VINYL "CHECKER PATTERN" - 3M SCOTCHPRINT VINYL (PMS 116C & 70% PMS 116C); RETAIN FACE w/ BLACK TRIMCAP • "PALM TREE/CPK° - 1/4° THICK ACRYLIC PAINTED BLACK. PIN MOUNT OFF FACE 1/4', PAINT STAND-OFF's BLACK • ILLUMINATE DIAMOND CABINET w/ 6500K WHITE GRID NEON w/ 60mATRANSFORMERS IN CABINET RIBBON CABINET: 4" DEEP ALUMINUM CABINET PAINTED PMS #116 YELLOW AND BLACK • 'CALIFORNIA° - ROUT-OUT/PUSH-THRU 1/2' CLEAR ACRYLIC w/ 1st SURFACE BLACK PERFORATED VINYL (BLACK @ DAY/WHITE @ NIGHT) w/ 2nd SURFACE WHITE DIFFUSER • "PIZZA KITCHEN° - ROUT-OUT/PUSH-THRU 1/2" CLEAR ACRYLIC w/ 1st SURFACE WHITE VINYL AND 2nd SURFACE (3635-70) DIFFUSER • ILLUMINATE CHANNEL w/ 6500K WHITE GRID NEON w/ 60mATRANSFORMERS LOCATED IN DIAMOND CABINET • RIBBON CABINET MOUNTS FLUSH TO FACE OF DIAMOND CABINET TubeArt Tube Art Displays, Inc. 1705 4th Avenue S Seattle, WA 98134 Tel 206 2231122 800 562 2854 Fax 206 2231123 ca _ LE))01m?2 tits 11' - 5-1/2" PAINT BRIDGE WHITE S - L_ CHANNEL LETTER LAYOUT - STRONG HORIZONTAL FORMAT SQ. FT. = 31.96 SCALE: 3/8" = 1' - 0" ALUM SPACERS (SPACERS TO BE PAINTED ON LOCATION TO MATCH FASCIA BY INSTALLER, PRIOR TO INSTALLATION) .040' PREFORMED ALUMINUM RETURNS - PAINTED BLACK 1' BLACKJEWELTTE RETAINER CLEAR POLYCARB. LETTER BACK W/2ND SURFACEARLON YELLOW (2500-525) VINYL 1/4' DIA RNNUT 8 THREADED ROD - NUT FROM BACKSIDE AS REQUIRED #2447 WHITE ACRYLIC LETTER FACE GLASS TUBE SUPPORT HI -FLEX MAX INTEGRATED GTO CABLE THRU 1/2' DIA SEALT1GHT CONDUIT (GRND'D.) POWERBOX' WEATHERPROOF HIGH-VOLTAGE SPLICE BOX BETWEEN CHANNEL LETTERS 60mA GFCI TRANSFORMER IN GROUNDED METAL BOX 6500 WHITE NEON TUBING PAINT INTERIOR LETTER RETURNS WTTN "STARBRITE' WHITE MIN. (2)1/4' DIA WEEP HOLES PER LETTER U.L LABELS REQUIRED INSTALL IN ACCORDANCE W/ NEC FACELIT / BACKLIT CHANNEL LETTER SECTION DETAIL SCALE: NTS ?.1111 NOTE; NO MANUFACTURE LABELS ALLOWED ON SIGNAGE UL LABELS TO BE PLACED IN THE LEAST VISIBLE EXTERIOR POSRION f Perft eNrc ' . k, SCS S N1.4:* DAC g4393C� . S o� 1 L'Tf.. • • L')A 1,1 0 WEST ELEVATION SCALE: 313T = 1' - 0° 111)' ID( \DI et) s ,f c -u) ?At, ‘,1 rigig g •••• Ea SOUTH ELEVATION TubeArt SCALE: 3/32 = 1' - 0° Tube Art Displays, Inc. 1705 4th Avenue S Seattle, WA 98134 Tel 206 223 1122 800 562 2854 Fax 206 223 1123 numir411111111"111471' 4144.0 man, .. - 1L 14:111151MMI Ca of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 (206 431-3670 PERMITNOSqn— O RECEIVED �- -o-1 Nov 0 8 200h PERMANENT SIGN PERMIT APPLICATION Please print UFANti \ 'i to (mooAl-sv›=.1eg. Ply Business Name Applicant/Contact Contractor r Address of Sign Phone flogs 4rf4 4' ' S . S eifirrt WA- 2•� , va 1V22 Phone Address, City, State, Zip Address, City, State, Zip 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) e r Supporting structure and method of illumination .2' One copy of valid Washington State contractor's license „c -Er $120 application fee per sign See back of form for examples Phone Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding 0 Did building go through design review? 0 Yes 421 No Wall 2 WALL SIGNS: #1 #2 #3 #4 , Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) �vo Z 751•�• a /�' VII Sign size(square feet) 3 r0 15. qy 3 55 Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of MDR or HDR zones. 'iv 1.�1.1LDR, �`� wall sign weigh more than 400 pounds?(Y/N) tt `` /v ,`Does bySign illumination (intemal/extemaVnone) e72NA4_ t f�J'TereA 4rS. t 4/ L.1G„r FREESTANDING SIGNS: #2 Street frontage of the entire premises where th - : will be located (feet). Generally, only one freestanding sign is allowed per premis - Height of building (feet). Generali igns may not be higher than the building withy hich they are associated Size of sign face (squ. - feet). Structural review is required for pole 'g1 with faces 30 square feet or more in are - Sign heigh eet-inches). Structural review is required for Igns 15 feet or more in height. Dis ce from closest edge of sign to prope nes (feet). Generally, signs must be set • -ck from all property lines a distance equ their height. ' Number of si • n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for foo ing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila will Date Zoning: Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions P:\ Planning Forms\ Applications\ PermSign-12-06.doc on 12/20/01 Revised COMMUNITY DEVELOPMENT