HomeMy WebLinkAboutPermit S08-012 - JC PENNEYJC PENNEY
2800 SOUTHCENTER MALL
S08-012
BUILDING MTG SIGN
File No.
Name of Tenant:
Sign Address:
Date Photo Taken:
Comments:
•
•
SITE INSPECTION (PLANNING)
S08-012
JC Penney
2800 Southcenter Mall
May 13, 2009
Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of XX/XX/200X
Make new site visit and take photo by XX/XX/200X
City ciltTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.cLtulcwila.wa.us
PERMANENT SIGN PERMIT
Parcel No.: 2623049085
Address: 1249 SOUTHCENTER MALL TUKW
Suite No:
Permit Number: S08-012
Issue Date: 02/27/2008
Permit Expires On: 08/25/2008
Business:
Name: JC PENNEY Phone:
Address: 1249 SOUTHCENTER MALL , TUKWILA WA
Property Owner:
Name: WEA SOUTHCENTER LLC Phone:
Address: 11601 WILSHIRE BLVD
Contact Person:
Name: JOSH CHRISTENSON Phone: 253-473-3323
Address: PLUMB SIGNS
Contractor:
Name: PLUMB SIGNS Phone: 253-473-3323
Address: 909 S 28TH ST
DESCRIPTION OF WORK:
Application Modified 2-28-08 for one wall sign on west elevation only. SM
Refund requested from Accounting. See Office Link for Memo.
Fees Collected: $125.00
PERMANENT SIGN:
Zoning: TUC Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 9780 0 0 0
Wall Sign Size (sq. feet): 149 0 0 0
Sign Lighting:
Face Residential Land: N N
Freestanding Sign #1 Freestanding Sign #2
Street Frontage for Entire Lot: 0 0
Building Height (feet): 0 0
Sign Size (sq. feet): 0 0
Sign Height (feet and inches): 0 ' 0 " 0 ' 0 "
Setback (feet): 0 0
Number of Sign Faces: 0 0
Planning Division Authorized Signature: 1111 + Date:
I hereby certify that I have read and examined t
governing this work will be complied with, whether specified herein or not.
't and know the same to be true and correct. All provisions of law and ordinances
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
doc: SIGN -PERM
S08-012
Printed:
•
MEMO
TO: Laurie Anderson, Finance Department
FROM: Stacy MacGregor, DCD Planning Intern
RE: Permit Fee Refund Request;
S08-012, JC Penney
DATE: 02/28/2008
Applicant:
Plumb Signs
c/o Josh Christenson
909 S 28th St
Tacoma, WA 98409
The applicant applied for two wall signs. The City of Tukwila sign code only allows one
additional sign for this site. A refund of $125 is requested for this applicant.
cc: email from applicant dated 2-2608 requesting permit revision and refund
• •
From: "Josh Christensen" <Josh@plumbsigns.com>
To: "DCD-Intern Intern" <smacgregor@ci.tukwila.wa.us>
Date: 02/26/2008 4:44 pm
Subject: JC Penney Westfield permit application
CC: "Connie Guffey" <Connie@plumbsigns.com>
Stacey,
Please revise the permit application for only (1) sign on the West
elevation. We will re -apply for the South elevation at a later date.
Also, please refund our payment for the South elevation sign.
Thank you,
Josh Christensen 1 direct: 253-473-3323 x36 1 cell: 253-381-3026 1 fax:
253-472-3107
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: S08-012
Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 02/07/2008
Applicant: PLUMB SIGNS Issue Date:
Receipt No.: R08-00346
Initials: SM
User ID: 1166
Payment Amount: $250.00
Payment Date: 02/07/2008 10:51 AM
Balance: $0.00
Payee: CONNIE GUFFEY OF PLUMB SIGN
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 18515 10.00
Payment Check 16838 , 240.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
SIGN PERMIT
000/322.100 250.00
Total: $250.00
8237 02/07 0710 TOTAL 500.OQ
rinr. RPcaint-Ofi Printwi: (12-f17-2f1OR
City o1.'ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100
Tukwila, Washington 98188
206 431-3670
PERM!
DATE:
an -01'x..
2_1aiDa
PERMANENT SIGN PERMIT APPLICATION
JC Penney
Business Name
Connie Guffey
Applicant/Contact
Plumb Signs Inc.
Contractor
Please print
2800 Southcenter Mall
Address of Sign
Phone
909 S. 28th St., Tacoma, 98409 (253)473-3323 x10
Address, City, State, Zip
909 S. 28th St., Tacoma,
Phone
98409 (253)473-3323
Address, City, State, Zip
Phone
CHECKLIST
3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
Sign elevations with area calculations and
dimensions
Building elevations (for wall signs)
Supporting structure and method of illumination
One copy of valid Washington State contractor's license
$100 application fee per sign
See back of form for examples
("0
Is your sign a:
❑ Freestanding si• 15 or more feet in height
❑ Pole sign w face 30 square feet or more in area
❑ Wall sweighing 400 pounds or more
If any • the above are true, the application must go through
structural review.
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
❑ Construction details to describe the proposed foundation
or wall attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding 0
Did building go through design review? Yes
❑ No
Wall 02.
WALL SIGNS:
06 'c-#1
- N13"#2
#3
#4
Wall area (length x height) where the sign will be
mounted? (square feet)
"I ��v
1 37
Sign size(square feet)
-711r.41401
Does sign face residential zones or public facilities?
(Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
4).0
p
Does wall sign weigh more than 400 pounds?(Y/N)
,,,...J0
d
Sign illumination (internal/external/none)
.........0 7-
APT
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
n / a
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
n/a
Size of sign face (square feet). Structural review is required for pole signs with faces 30
square feet or more in area
n /a
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
n /a
Distance from closest edge of sign to property lines (feet). Generally, signs must be set back
from all property lines a distance equal to their height.
Number of sign faces
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing'inspections must take place before concrete Is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation Is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and
that the applicable requirements of the City of Tukwila will be met.
,4oP ` (253) 473-3323
(Signature of .wner or
Date
agent)
Phone
FOR OFFICE USE ONLY
Zoning:
Planning review by:
0 Denied
0 Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
0 Denied 0 Approved 0 Approved with conditions
q26\ftst,e.a 3' I g -101 -O)
qe,\aszi\--) oc\ off'
(Vde,,sr
!-j oc, f7o./ `
Jtl�C `ia<ap�__�WgitEl. •at
rte! A�
Caine A - South Elav
tar.u.. A... HAP q.a.
a D
ALLIANCE
7 Y 24' 74051'
IOTA
Dk
6
A\N\ 936
Garage B
�.-.•.l S les,...) 04.
°_P P rIV ` & . vt, --
4 t,
1:1
Garage B - West Elevation
Art.
' BIWi- 4wANCE
'c
Garage G - So
J
•
o
A
l iF'W kA1iKtN�
SIklt(141i4 :.
AA1 Main ID Pylon
AA3 Mall Entry ID - Secondary
AA4 Mall Entry ID - Primary
AA5 Bridge Mounted Parking ID
AA6 Bridge Mounted Westfield ID
SIGN LEGEND
AB1 Restaurant Totem
AD1 Primary Vehicular Directional
AF1 Street Sign (Lupine Drive)
• Power required
• No power required
Sods -oil
Client
Westfield Design
11601 Wilshire Blvd, 11th Floor
Los Angeles, CA 90025
Graphic Consultant
IIBAIE PEOMenilli
5515 Day's Street Saito 15
Enaryvilla. Calitouis 946013
T.Isphsis 510.518.8110
Fiisiuilo 510.591.1814
Project
Southcenter
633 Southcenter
Seattle, WA 98188
Project Number
6307.00
Date
Document
06/02/06
75% Documentation
10/25/06
80% Documentation
02/09/07
3/30/07
95% Documentation
5/31/07
98% Documentation
8/24/07 100% Documentation
11/09/07 Addendum A !H\ SPD Revision
Drawing Title
Sign Location Plan
South Site - New Mall
Drawing Number
LP 102.00
•
Tenant Sign
dAe} ft
5'-0- H.max
Garage B - West Elevation
Westfield ID
127 sq. ft
Garage B - South Elevation
0 10 20 50
SCALE: 1 "= 20'-0"
100
Garage B - East Elevation
�•r
Tenant Sign
ti2ieq.ft
5'-0" 11. max
SQ;udtt, Vie. 11!hlaN!
Si 16 C./%. t,i..t
SO. ,S
1., ,.in.
10113
f.... 111 SIC 1111
Proposed Garage Elevations
12/05/2006
Rev. 4/19/2007
Sc- cVL
Westfield
Southcenter
633 Southcenter
Seattle, WA 98188
06
SGN118
29'-1 3/4" (349.75")
SCALE: 3/8"=1'-0"
4'-10 1/8"
(58.125")
(60")
13 1/8"
SGN118
INTERNALLY ILLUMINATED CHANNEL LETTER SET
" ALUMINUM CONSTRUCTION LETTERS
- 8" RETURNS
- .063" PAINTED DURANODIC BRONZE #313
- .125" BACKS
3/16" WHITE #7328 ACRYLIC FACES (015-2).
- 2" DURANODIC BRONZE TRIMCAP.
*15MM 6500 WHITE NEON
- DOUBLE STROKE ILLUMINATION
SELF-CONTAINED UNITS
g" 21/2"
2" TRIMCAP
2 1/2" STEEL
ANGLE CLIPS
- DISCONNECT SWITCH BEHIND EACH LETTER (SWITCH MOUNTED SIDEWAYS).
CLIP MOUNT 21/2" OFF SURFACE OF FASCIA
- SINGLE WEATHER TIGHT ELECTRICAL PENETRATION BEHIND EACH LETTER
- 6" FROM BOTTOM OF LETTER WITH 25' PRIMARY LEAD LENGTH.
- MAY VARY BY LOCATION.
15MM 6500
WHITE NEON
HIGH POWER
FACTOR HOUSING
TRANSFORMER
DISCONNECT SWITCH
.3/16" ACRYLIC FACE
COLOR TO VARY
INCOMING PRIMARY IN
CONDUIT WITH V2"
RIGID CONNECTOR
JCPenney
SIMULATED NIGHT VIEW
41/2" GLASS
TUBE STAND
.063" ALUMINUM RETURNS
.125" ALUMINUM BACKS