HomeMy WebLinkAboutPermit S08-017 - PAYLESS SHOESPAYLESS SHOES
17250 SOUTHCENTER PKWY
S08-017
FREE STANDING
SIGN
File No.
Name of Tenant:
Sign Address:
Date Photo Taken:
SITE INSPECTION (PLANNING)
S08-017
Payless Shoesource
17250 Southcenter Py
June 19, 2008
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of XX/XX/200X
Make new site visit and take photo by XX/XX/200X
Comments: Sign inspected and meets code. CB 06.19.08
City #' Tukwila 1
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
PERMANENT SIGN PERMIT
Parcel No.: 2623049117
Address: 17250 SOUTHCENTER PY TUKW
Suite No:
Permit Number: S08-017
Issue Date: 02/29/2008
Permit Expires On: 08/27/2008
Business:
Name: PAYLESS SHOESOURCE Phone:
Address: 17250 SOUTHCENTER PKWY , TUKWILA, WA 98188
Property Owner:
Name: WIG PROPERTIES LLC -SS Phone:
Address: 4811 134TH PL SE
Contact Person:
Name: JEFF WADZINSKI Phone: 425 277-5966
Address:
Contractor:
Name: ILLUMINATIONS NORTHWEST Phone: 425 277-5966
Address: 15632 156TH PL SE
DESCRIPTION OF WORK:
TWO WALL SIGNS FOR PAYLESS SHOESOURCE PERMITTED AS APPLIED IN APPLICATION. CB
Fees Collected: $250.00
PERMANENT SIGN:
Zoning: TUC Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 933.24 784 0 0
Wall Sign Size (sq. feet): 36.81 29.57 0 0
Sign Lighting:
Face Residential Land: N N
Freestanding Sign #1 Freestanding Sign #2
Street Frontage for Entire Lot: 0 0
Building Height (feet): 0 0
Sign Size (sq. feet): 0 0
Sign Height (feet and inches): 0 ' 0 " 0 ' 0 "
Setback (feet): 0 0
Number of Sign Faces: 0 0
Planning Division Authorized Signature: Date: o7- 79.08
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
doc: SIGN -PERM S08-017 Printed:
02-29-2008
of Tukwila
D rrtment of Colmmunity Development
6300 Southcenter Boulevard, Suite 100 DATE:
Tukwila, Washington 98188
206 431-3670
PERMIT N•4 D 3-1)1 7
a -I 1&l t 7a
PERMANENT SIGN PERMIT APPLICATION
Please pnnt
f « G%5' chvtvs / 7 S'0 - 1 Pnluoi
Busin Name ddress of Sign Phone
T l c)t—z iAsic r ) s-�� a .?( �� sc tate, Zip yaps -a 7� X77 -7 5 r, G
Applicant/Contt-A—v. t.\l/t 4Y-4,c7ns /��ji3`S` �ct Address, '�ty, S( 3 0- 15-6(L sC 6 on'1 5"`O' c ( -S 1 L6
Contractor Address, City, State, Zip 77l� Phone
❑ 3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
'• Streets
• Buildings
• Locations of all existing and proposed signs
❑ Sign elevations with area calculations and dimensions
❑ Building elevations (for wall signs)
❑ Supporting structure and method of illumination
❑ One copy of valid Washington State contractols license
❑ $125 application fee per sign
See back of form for examples
Is your sign a:
❑ Freestanding sign 15 or more feet in height
❑ Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
H any of the above are true, the application must go
through structural review.
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
❑ Construction details to describe the proposed foundation or
wall attachments (see back of form for examples) •
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding
Did building go through design review? ❑ Yes ❑ No
Wall
WALL SIGNS:
#1
#2
#3 •
#4
Wall area (length x height) of the tenant space where the
sign will be mounted? (square feet)
Sign size(square feet)
3.1g . i'
33 - a3
Does sign face residential zones or public facilities? (Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
• JJa
1\16
Does wall sign weigh more than 400 pounds?(Y/N)
,fJ p
iil
Sign illumination (intemal/extemal/none)
:,tN.Nv
p t n,
(vJaw q
l%1°
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
Height of building (feet). Generally, signs may not be higher than the building with which they .
are associated
Size of sign face (square feet). Structural review is required for pole signs with faces 30 square
feet or more in area
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
Distance from closest edge of sign to property lines (feet). Generally, signs must be set
back from all property lines a distance equal to their height.
Number of si. n faces
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that
the applicable requirements of the City of Tukwila wit • met
Date
// Lc, .€ LIaL�
Email Address
Zoning:
FOR OFFICE USE ONLY
Planning review by:
O Denied
❑ • Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
O Denied ❑ Approved 0 Approved with conditions
P:\Planning Forms \ Applications \2007 Applications \ PermSign-12-07.doc
Revised on 12-07
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049117 Permit Number: S08-017
Address: 17250 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 02/19/2008
Applicant: JEFF WADZINSKI Issue Date:
Receipt No.: R08-00461
Initials: WER
User ID: 1655
Payment Amount: $250.00
Payment Date: 02/19/2008 09:29 AM
Balance: $0.00
Payee: ILLUMINATIONS NORTHWEST
TRANSACTION LIST:
Type Method Description Amount
Payment Check 1027 250.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
SIGN PERMIT
000/322.100 250.00
Total: $250.00
8798 02/19 9710 TOTAL. 394.00
rtnr. Rar.Pint-nR
Printari: 02 -14 -Inns
C;,.D-Intern2 Intern2 - Tukwila Pylon.pdf
Page 1
Utica' -,
ORESSU
Q'u'.11►111 t \\
• ..hr,}u�ra zc�l.p
DfIESSDANN
Ml( on..... ,
(0'
NORgsr•RO%1 RaCK'7,``
USW5H0Fs
DRESSBARN n"
• veri onw-, ss
�jC_ ergo
I1A,t Ia.),
DSW.+s�
DRESSBANN :..'�...
urn an..,Y,n
•
1OX(.76"= lZ.5P�.2 7-6-9/
6-Intern2 Intern2 - Tukwila Pylon.pdf
•
Page 2'
C �o�
4..(},5,--6-c
Ca • -7, v
J 6.7__
Loa Angeles, CA • Dallas, TX I
Re
SOU
S C H: E DSU L E-
NI-
Nt - PROPOSED ILLUMINATED CHANNEL LETTERS SHOP DRAWING REVIEW
N2 - PROPOSED NON -ILLUMINATED BLADE S
0 NO EXCEPTIONS TAKEN Q RE ECTW 'NOTE MARKINGS
A,xh tacts raft* Is for genial cardamoms wins the design concept and
contract domrmanta. Markings of cammmlia an the submbllel dotunlante
demi rearm ma ie centrederfmmamaWtoxe sseth dm roofed dans
endsensitisation. The contractor remeeel'amenable tar details and
mums, for anndrMng andcmrstotbig all quantities and dimensions.
for aelocting fabrication Montana. for tsdmlques of aanembh• and los
performing his work in s sato man
BY
IiI?9A1./0%•
INC. P.S. • . W
LEGEND
EXISTING SIGN
TO BE REPLACED,
NEW
PROPOSED SIGN
EXISTING SIGN
TO BE REMOVED
EXISTING SIGN
TO REMAIN
t. O/' T A L SIGN A, R E A
• ALLOWED SQ. FT. 73.0
MAX LETTER HEIGHT NTE: 48"
PROPOSED SQ. FT. 71.6
;N e2 8 $ g
gip sr :9 11,0:8 O . .
;.r 8llff ' r..rt rr.�7-raa<c'r t.
8' -8 ..gig.. ,g ;g g Y B
Y 811 E.
3
8..,Y Y {� g 'Y •8 u t'wroo`�
Q r m. `z (B 9 44 s_
,g 2 r g i:. ivri Q`uc.
6 r
❑ VICINITY MAP/AERIAL PHOTO
Not To Scale
❑ SITE PLAN
koro -0=o
htrpoWL aliPfflaciP
cny
Not To Scale
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whittler. CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lit.: 455415
IffieleirathEMSMIICP.:
08-01-0034R1
MEAL:
1 OF 4
Payless Shoesource
6299ES5
9TOREa1723
17250 Southcenter Pkwy.
14kwila, W69618$ -330t
C9tn6CL
01/21/2008
wine,
Dan Lorenzon
M OSEL
Will Cantor
•
Knassetaac
01/30/2008
maze=
Will Cantor
rwe, row EIEClaanx
an imxamOM MS ou+,nw us
METR� t ARO
�o113, M.O. .
0aw.lxe rw ANT
M .aiAr-r.0-.agar
KIUMtxla d LOW. ratClax
Payless ShoeSource
SouthCenter Square
17250 Southcenter Pkwy,
Tukwila, WA 98188-3301
SE -1723 -L -S5
LEGEND
EXISTING SIGN
TO BE REPLACED,
NEW
PROPOSED SIGN
EXISTING SIGN
TO BE REMOVED
EXISTING SIGN
TO REMAIN
t. O/' T A L SIGN A, R E A
• ALLOWED SQ. FT. 73.0
MAX LETTER HEIGHT NTE: 48"
PROPOSED SQ. FT. 71.6
;N e2 8 $ g
gip sr :9 11,0:8 O . .
;.r 8llff ' r..rt rr.�7-raa<c'r t.
8' -8 ..gig.. ,g ;g g Y B
Y 811 E.
3
8..,Y Y {� g 'Y •8 u t'wroo`�
Q r m. `z (B 9 44 s_
,g 2 r g i:. ivri Q`uc.
6 r
❑ VICINITY MAP/AERIAL PHOTO
Not To Scale
❑ SITE PLAN
koro -0=o
htrpoWL aliPfflaciP
cny
Not To Scale
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whittler. CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lit.: 455415
IffieleirathEMSMIICP.:
08-01-0034R1
MEAL:
1 OF 4
Payless Shoesource
6299ES5
9TOREa1723
17250 Southcenter Pkwy.
14kwila, W69618$ -330t
C9tn6CL
01/21/2008
wine,
Dan Lorenzon
M OSEL
Will Cantor
•
Knassetaac
01/30/2008
maze=
Will Cantor
rwe, row EIEClaanx
an imxamOM MS ou+,nw us
METR� t ARO
�o113, M.O. .
0aw.lxe rw ANT
M .aiAr-r.0-.agar
KIUMtxla d LOW. ratClax
1 Los Angeles, CA • Dallas, TX I
26"
17 3/4"
SHOESOURCE
65
26"
5 3/4••
N2 l 26-26HC ILLUMINATED CHANNEL LETTERS
TOTAL AREA - 33.23 SQ. FT. Scale: 3/4" = 1'-0"
28'- 0"
DI
REAR ELEVATION
mum
1111 lIl1�
X1111111
EC
APPRov46 60071646:2
WA) tte L8'(
4 to
v
`TnTrIMrtmmr
Scale: 1/8" = 1'-0"
1!.!
LDR�1
LOREN ELECTRIC
SIGN CORPORATION
11226 Coast Drive
Whittler, CA 90601
Tel: (562) 946.7545
Fax: (562) 949.5707
St. Lic.: 455415
DXAUe1GIRE9alpl IO
08-01 -0034R1
PAGE 90„
2 or 4
CUM
Payless Shoesource
Ong
• STOREFi723
57250nter Pkwy.
Tukwila,IO.WA WA 98188.3301
CDMACO
1161.21
01/21/2008
L,IrS SED.
Dan Lorenzon
Drama
Will Cantor
6NKNM R.rc
01/30/2008
emsittan
Will Cantor
P111014. PUNS. MP Isantokic
ART ISOICISSO ON DRS 014.1•14
�4XIC; � OW�.»o
Lw.lt MOT 11 XSPROOM R. USER
RT OR OSSO TOM, POSOSO.
EOM edl CRVr,.TgY MORNS
PURPOSE soars mTnwT
,KNR.W UMW
CORPOR,WY.
ata
N1 - PROPOSED
N2 - PROPOSED
ILLUMINATED CHANNEL LETTERS
NON -ILLUMINATED BLADE SIGN
"VICINITY MAP/AERIAL PHOTO
Not To Scale
Payle.ShoeSource
SouthCenter Square
17250 Southcenter Pkwy,
Tukwila, WA 98188-3301
SE -1723 -L -S5
EXISTING SIGN
TO BE REPLACED
NEW
PROPOSED SIGN
EXISTING SIGN
TO BE REMOVED
EXISTING SIGN
TO REMAIN
TOTAL
N A ._R E
y:y
ALLOWED SQ. FT. 73.0
MAX LETTER HEIGHT NTE: 48"
PROPOSED SQ. FT. 71.6
SITE PLAN
- nt4
Not To Scale
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lic.: 455415
Los Angeles, CA • Dallas, TX
DRAWING/REVISION NO.:
08-01-0034R1
PAGE NO.:
1 OF 4
CLIENT:
Payless Shoesource
ADDRESS
STORE#1723
17250 Southcenter Pkwy.
Tukwila, WA 98188-3301
CONTACT:
DATE:
01/21/2008
SALES REP:
Dan Lorenzon
DESIGNER:
Will Cantor
REVISION DATE:
01/30/2008
REVISION BY:
Will Cantor
AU. IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
26-26HC ILLUMINATED CHANNEL LETTERS
TOTAL AREA - 42.32 SQ. FT.
7i STOREFRONT ELEVATION
q
ES URIC_
65"
11-otAA' u%
T
26"
A lie (eteAA'. Ax(
5 3/4"
28'- 0"
rn
0
PFP)49.1ess
rn
p
0000000,00mommung 11,4,44.4.414,4
m 0
1
I
Scale: 3/4" = 1'-0"
t1
E e�r'
Lk4
til4°
• cfc,
33%•011-
rfi_
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lic.: 455415
Los Angeles, CA • Dallas, TX
pRAWING/REVISION NO.:
08-01-0034R2
PAGE NO.'
2 of 4
CLIENT:
Payless Shoesource
ADDRESS
STORE#1723
17250 Southcenter Pkwy.
Tukwila, WA 98188-3301
CONTACT:
QAIL;
01/21/2008
SALES REP'
Dan Lorenzon
DESIGNER:
Will Cantor
REVISION DATE;
02/25/2008
REVISION BY:
Will Cantor
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO MW PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
22 "
f
22"
C /
Jl 22-22HC ILLUMINATED CHANNEL LETTERS
_f TOTAL AREA - 30.30 SQ. FT.
1-1 REAR ELEVATION
•
116 1/4"
ES cA C
55"
28'- 0"
EQ
1
22"
i
4 3/4"
�P 0,,,c°
ao•
11111111111111111111
f e
a' 8 Is
IIIIIIlII11Illllllll)
IIRIDIuhIllhIII111
11111111111111111111
11111111111111111111
4
•
J \\ k IG(Lfii
.063 black aluminum "eyebrow"
5" deep .050 aluminum
returns painted matte black
3/4" Black Trim Cap
3/16" White acrylic face
M #3630-84 Tangerine vinyl applied to face
Avery A9502 -T Baby Blue vinyl
.063 Aluminum Backs
6500 White Neon
Letter Interior Painted White
Glass Stand
GTO
Electrode Boot
Drain Hole
Wall (varies)
@LISTED
Minimum (4) Per Letter
Primary Electrical solift
(1/2" Conduit MinimuAllretat Shown)
Ref: Nec 600-6 & 600-21
Listed Disconnect Switch In Primary
To Be Within Sight Of Sign (sign
Includes Transformer Enclosure)
Ref: Nec 110-3 (b), 600-2, 600-4
3/8" minimum listed Conduit (metal shown)
ft Listed gto cable (secondary side only a
to the next section letter)
Ref: nec 110-3 (b) ft 600-31
ELECTRIC SIGN SECTION
Listed Sign Section
(consists Of Transformer
And Enclosure) Suitable For
Outdoor Locations Unless
Marked For Indoors Only
Bonding Jumpers (#14 Awg Cu Min) With Listed Connection
Device Or Fitting Required If (1) All Flexible Metal Conduit In
Installation Used As A Ground Return Path Exceeds 6 Ft. (ref
Nec 350-5 Exc. 2), Or (2) Channel Letter Is Non Metallic, Ref.
NEC 250-43 (G), 250-111 600-5
A. Between Primary Wiring AM insulated High Voltage WI,ing
B. Between Insulated High Voltage Wiring And Dead Metal
Where Wiring Parallels Dead Metal For More Than 1- Wlthln
Sign Sections.
C. Between Neon Tube (H Over 75000 Volt Ctrcdtl And Dead Metal
D. Between Unbwdated High Voltage Conductors Or
Components. ImtdpoInt.grou ded Ttanstomner) And
Metal (ground) LOW Voltage Circuit Conductor And High
Voltage Conductors Of Opposite Polartt
NOTE: GFI TRANSFORMERS IN ACCORDANCE WITH 2161arillaq. MO= E53=1
Massa
. ''ii::_9�i71ui:'r�i1L1I:'�:■arescva1a uynt �7
ill �.,a"ua�.1 d7��[gl•'7—ft i[671.^B
\ NEON ILLUMINATED CHANNEL LOGO SECTION DETAIL (ICON)
Scale: N.T.S.
3" deep .050 aluminum
returns painted matte black
3/4" Black Trim Cap
3/16" White acrylic face
SLOAN White L.E.D.
Letter interior painted white
Flexible conduit
.063 Aluminum Backs
Low voltage power supply
Drain Hole w/ light baffle � j)
.063 black aluminum "eyebrow"
Wall (varies)
5" deep .050 aluminum
returns painted matte black
3/4" Black Trim Cap
3/16" White acrylic face
.063 Aluminum Backs
Minimum (4) Per Letter
rill Primary Electrical Source
(1/2" Conduit Minimum, Metal Shown)
Ref: Nec 600-6 & 600-21
6500 White Neon 3
Letter Interior Painted White —1
Glass Stand
GTO
Electrode Boot
Drain Hole
.063 black aluminum "eyebrow"
@LISTED
Wall (varies)
Listed Disconnect Switch In Primary
To Be Within Sight Of Sign (sign
Includes Transformer Enclosure)
Ref: Nec 110-3 (b), 600-2, 600-4
3/8" minimum listed Conduit (metal shown)
& Listed gto cable (secondary side only &
to the next section letter)
Ref: nec 110-3 (b) & 600-31
Listed Sign Section
17— (consists Of Transformer
ELECTRIC SIGN SECTION
And Enclosure) Suitable For
Outdoor Locations Unless
-*TT Marked For Indoors Only
•
—Bonding Jumpers (#14 Awg Cu Min) With Listed Connection
Device Or Fitting Required If (1) All Flexible Metal Conduit In
Installation Used As A Ground Return Path Exceeds 6 Ft. (ref
Nec 350-5 Exc. 2), Or (2) Channel Letter Is Non Metallic, Ref.
NEC 250-43 (G), 250-113, AND 600-5
SPACING TAULE
A. Between Primary Wiring And !mutated Nigh Voltage Wtrfng
B. Between Insulated High Voltage Wiring And Dead Metal
Where Wiring Parallels Dead Metal For More Than 1' Within
Sign Sections.
C. Between Neon Tobe (If Over 75000 Volt Ctrcuft) And Dead Metal
D. Between Uninsulated High Voltage Conductors Or
Comments. (mfdpolntwounded Transformer) And
Metal (ground) Low Voltage Circuit Conductors And High
Voltage Conductors Of Opposite Polarity
NOTE: GFI TRANSFORMERS IN ACCORDANCE WITH 2161
_...Th,'.._— -- —,—
IAateti5fl1ret
IIILILL.A1' 1132=11
lMk 1L .. - It1Ct1reM ETCIITd7 lyri014:I:a111T/T.,
sp,..11,41.:671NumimixTroczITIFIERIN
toot 10 5000
NEON ILLUMINATED CHANNEL LETTER SECTION DETAIL (Payless)
Mechanical Fasteners
Minimum (4) Per Letter
Primary Electrical Source
(11r Conduit Minimum, Metal Shown)
Ref: Nec 600-6 & 600-21
Listed Disconnect Switch In Primary
To Be Within Sight Of Sign (sign
Includes Transformer Enclosure)
Ref: Nec 110-3 (b), 600-2, 600-4
3/8' minimum listed Conduit (metal shown)
& Listed gto cable (secondary side only &
to the next section letter)
Ref: nec 110-3 (b) & 600-31
L.E.D. ILLUMINATED C/L SECTION DETAIL (SHOESOURCE)
Scale: N.T.S.
Scale: N.T.S.
sc- 04
LOREN
ELECTRIC
SIGN CORPORATIO
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946-754!
Fax: (562) 949-570
St. Llc.: 455415
Los Angeles, CA • Dallas, 1
DRAWING/REVISION NO.:
08-01-0034R1
PAGE NO.:
4 OF 4
CLIENT:
Payless Shoesourc
ADDRESS
STORE#1723
17250 Southcenter Pkwy.
Tukwila, WA 98188-3301
CONTACT:
DATE:
01/21/2008
SALES REP.:
Dan Lorenzon
DESIGNER:
Will Cantor
REVISION DATE:
01/30/2008
REVISION BY:
Will Cantor
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING AR
COPYRIGHTED AND OWNED BY LOREI
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PFRMICVn" nF r roc., Fr FrroIr