HomeMy WebLinkAboutPermit S08-024 - CHEVRONCHEVRON STATION 15060 INTERNATIONAL BLVD S08-024 FREESTANDING SIGN SITE INSPECTION (PLANNING) File No. S08-024 Name of Tenant: Chevron Sign Address: 15060 TIB Date Photo Taken: August 27, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CB 08.27.08 Gasoline 5.1S.`. 3891- 3 9 9 A 89399; e. �'t-�m 409;.1 City aeTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 0041000680 Permit Number: S08-024 Address: 15060 TUKWILA INTERNATIONAL BL TUKW Issue Date: 04/07/2008 Suite No: Permit Expires On: 10/04/2008 Business: Name: CHEVRON Phone: Address: 15060 TUKWILA INTERNATIONAL BLVD , Property Owner: Name: MCNAMARA FLORINE Phone: Address: 5245 BELL CT Contact Person: Name: STEVEN THOMSON - INSIGNIA SIGNS Phone: 425 917-2109 Address: 325 BURNETT AVE N RENTON WA 98056 Contractor: Name: Phone: Address: DESCRIPTION OF WORK: Refacing of freestanding sign, replacing two wall signs as part of a brand re-imaging process. CB Fees Collected: $375.00 PERMANENT SIGN: Zoning: RC Sign Type: Wall Sign #1 Wall Sicm #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 339.5 77 0 0 Wall Sign Size (sq. feet): 20.96 5.01 0 0 Sign Lighting: Face Residential Land: N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 430 0 Building Height (feet): 20 0 Sign Size (sq. feet): 106.74 0 Sign Height (feet and inches): 13 ' 6 " 0 ' 0 " Setback (feet): 14 0 Number of Sign Faces: 2 0 Planning Division Authorized Signature. Date: a 677- I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-024 Printed: 04-07-2008 to 1 Steven, Thanks for the .pdf of the "Extra Mile" sign at this site. I have made the measurements and subtracted the open area of the sign from the total of 26.25 sq ft and found the sign to be 19.3 sq ft putting this sign within compliance of TMC 19.32.160 [3.] based on the conditional agreement that the sign is non -illuminated, meaning the sign must now be unplugged. As a little FYI, after our meeting on Friday I went back and researched the permitting of the "Extra Mile" sign which took place in 2005 [S05-034]. What I discovered is that when the application was submitted it did not include the "Chevron" channel lettering on the outer canopy [facing TIB] nor did it include the Chevron logo sign on the opposite side of the canopy from the channel cut sign as being permanent, existing signage on the site. Therefore, when the planner working on that file issued the permit he/she did so under the assumption that this was the only permanent signage on the site [which explains why the installed "Extra Mile" sign is illuminated even though it was issued a permit]. This is not, however, the applicant's fault. The planner never did a site visit before approving the permit nor did the installed signage ever get finalized according to administrative procedure six months after issuing the permit. The planner also could have avoided this problem by simply researching the permits issued for permanent signs on the site and discovered the original permits for the existing signs issued in 1997. As we discussed before however, TMC requires all non -conforming uses to be brought into compliance with the code before allowing any sort of refacing or replacing of signage on site. We appreciate you working closely with us on finding a resolution to this issue and look forward to working with you in the future. The permit for this project is currently approved, issued and will be waiting for you to pick up at will -call here at the Tukwila DCD office when ever you are ready. Please call or ask for me [or Stacy MacGregor] if you have any other questions or concerns regarding this permit. My number is 206 433-7141. thanks, Chris Beale Planning Intern DCD-Planning ex. 1141 email: DCD-Intern2 cbeale©ci.tukwila.wa.us City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0041000680 Permit Number: S08-024 Address: 15060 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 03/18/2008 Applicant: STEVEN THOMSON Issue Date: Receipt No.: R08-00813 Payment Amount: $375.00 Initials: MD Payment Date: 03/18/2008 01:30 PM User ID: 1685 Balance: $0.00 Payee: INSIGNIA SIGN INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3419 375.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 375.00 Total: $375.00 0135 03/18 9710 TOTAL 375.00 don: RPraint-06 Printari: 03-1 R -200A City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hUp://www.citukwila.wa.us RECEIPT Parcel No.: 0041000680 Permit Number: S08-024 Address: 15060 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 03/18/2008 Applicant: STEVEN THOMSON Issue Date: 04/07/2008 Receipt No.: R08-00813 Initials: MD User ID: 1685 Payment Amount: $375.00 Payment Date: 03/18/2008 01:30 PM Balance: $0.00 Payee: INSIGNIA SIGN INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3419 375.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 375.00 Total: $375.00 doc: Receipt -06 Printed: 04-07-2008 RECEVD City oukwila MAR4Sor- B Department of Community Development p�A 6300 Southcenter Boulevard, Suite 100 DEMENT Tukwila, Washington 98188 206 431-3670 W TUKWILA W PERMANENT SIGN PERMIT APPLICATION Chevron Sfctiion Business Name Sf eve n -Thomson Applicant/Contact Illi nim Sign Inc Contract Please print I56)&0 I14-'/ iIvd Address of Sign Po Box gggq, P elion wA q go56 Address, City, State, Zip 4 Address, City, State, Zip 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $100 application fee per sign See back of form for examples gas- g17-a/aq hone Phone Phone Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: O $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). O Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? 0 Yes ❑ No Wall WALL SIGNS: #1 la) #2 0 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) 2� J �,5 i 4, Sign size(square feet) .a 1 5f 5 s Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. ND NA 1 Ivo p I A D `� �I Does wall sign weigh more than 400 pounds?(Y/N) No Na Sign illumination (internal/external/none) in-temtA I i h feiroz, J FREESTANDING SIGNS: >k1PlE�FAer vfVg r #1( #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. YI'70 = In -ti 84 ''aGO.4 Ad.SA Height of building (feet). Generally, signs may not be higher than the building with which they are associated n, 30 Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area 515E1-1Pj 11 Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Ia ' 13 113 Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. (fir°' 15?K4 13 FroinT. @iI Number of sign faces .II ' INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS V LID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information ished by me is e and correct under penalty of perjury by law in the State of Washington, and that thepplicable requirements of the City of T ila will be met S� / 08 ( LOS -co- ►09 Date-ignature of •w r or authorized aent)�Pnf) Phone FOR OFFICE USE ONLY Zoning: Planning review by: 0 Denied 0 Issued 0 Issued with conditions Structural review required? ❑ Yes 0 No Structural review by: 0 Denied 0 Approved ❑ Approved with conditions MEMORY TRANSMISSI•REPORT FILE NO. 605 DATE : 03.21 11:32 TO : E19* -4259170153 DOCUMENT PAGES 3 START TIME : 03.21 11:32 END TIME : 03.21 11:33 PAGES SENT : 3 STATUS OK *** SUCCESSFUL TX NOTICE Mr. Stephen Thomson Insignia Sign Sc Rs -Imaging 325 Burnett .Ave 11 Raritan. WA. 98056 RE: S08-024 -- Chevron image refresh project Mr. Thomson, • TIME :03-21-'08 11:33 FAX NO.1 :2064313665 NAME :publicworks/dcd *** March 21, 2008 This letter is in reference to the Chevron image refresh project for the site at 1 5060 Tukwila International Blvd [TIB]. There are a few different issues that need to be contended with before the project can be issued a permit approval. 1. The "Extra Mile" wall sign above the front doors of the main building on the site facing Tukwila International Blvd. Only one illuminated sign facing TIB is allowed. A. second sign facing the same direction is allowed provided it is non -illuminated and Icss than 20 square feet [sec Tukwila Municipal Code [TMC] 19.32.160 [2.]]. According to the measurements provided, the "Extra Mile" sign is 7'-6" by 3'-6", making the square footage of the sign 26.25. Therefore, the "Extra Mile" sign is riot allowed per the TMC unless resited to fit the code's criteria or removed all together. 2. The Chevron insignia logos and additional advertisements that are on the fuel pump islands :Fall under the category of signs according to TMC 19.08.210. TMC 19.32.160 [4.a] states, "Signs at each pump island denoting the type of fuel, price and service available. providing such signs are permanently mounted to pumps or pump island structures" are allowed without a permit. However, because only one wall sign is permitted far each exposed building facts on each street frontage — which, in this case, is represented by the sign "C" in the plans submitted — these insignia logos exceed the allowable signage onsite. The Chevron insignia logo that is on the upper portion of each of the islands [above the pump numbers] along with the Chevron insignia logo below each of the island pump handles are therefore not allowed per the TMC. TMC 19.32.160 [4.b] states, "Signs on roll -away type racks advertising merchandise on such racks [...] examples include tire racks, batteries, bulk oil sales etc." are allowed without permitting_ Therefore, the small stand signs above each pump handle, pole attachment signs next to the pump handles along with the larger insert poster signs next to the pump island poles are not allowed under the TMC because they also exceed the allowable signage onsite. TMC 19.30.030 requires that any alteration, relocation, resurface, replacement or change in any way to a sign require that all signs on site be brought up to current cods_ • • March 21, 2008 Mr. Stephen Thomson Insignia Sign & Re -Imaging 325 Burnett Ave N Renton, WA 98056 RE: S08-024 -- Chevron image refresh project Mr. Thomson, This letter is in reference to the Chevron image refresh project for the site at 15060 Tukwila International Blvd [TIB]. There are a few different issues that need to be contended with before the project can be issued a permit approval. 1. The "Extra Mile" wall sign above the front doors of the main building on the site facing Tukwila International Blvd. Only one illuminated sign facing TIB is allowed. A second sign facing the same direction is allowed provided it is non -illuminated and less than 20 square feet [see Tukwila Municipal Code [TMC] 19.32.160 [3.]]. According to the measurements provided, the "Extra Mile" sign is 7'-6" by 3'-6", making the square footage of the sign 26.25. Therefore, the "Extra Mile" sign is not allowed per the TMC unless resized to fit the code's criteria or removed all together. 2. The Chevron insignia logos and additional advertisements that are on the fuel pump islands fall under the category of signs according to TMC 19.08.210. TMC 19.32.160 [4.a] states, "Signs at each pump island denoting the type of fuel, price and service available, providing such signs are permanently mounted to pumps or pump island structures" are allowed without a permit. However, because only one wall sign is permitted for each exposed building face on each street frontage — which, in this case, is represented by the sign "C" in the plans submitted — these insignia logos exceed the allowable signage onsite. The Chevron insignia logo that is on the upper portion of each of the islands [above the pump numbers] along with the Chevron insignia logo below each of the island pump handles are therefore not allowed per the TMC. TMC 19.32.160 [4.b] states, "Signs on roll -away type racks advertising merchandise on such racks [...] examples include tire racks, batteries, bulk oil sales etc." are allowed without permitting. Therefore, the small stand signs above each pump handle, pole attachment signs next to the pump handles along with the larger insert poster signs next to the pump island poles are not allowed under the TMC because they also exceed the allowable signage onsite. TMC 19.30.030 requires that any alteration, relocation, resurface, replacement or change in any way to a sign require that all signs on site be brought up to current code. • • Therefore, the pump island Chevron logos and additional advertisement stands and posters need to be removed and the "Extra Mile" wall sign needs to be either resized to fit code requirements or removed completely in order for the City to approve and issue a permit for this project. Please give me a call is you need clarification on these requirements. Attached is a copy of TMC 19.32.160 — Service Stations — for your reference on these decisions. I can be reached directly at [206] 433-7141. Chris Beale, Planner Department of Community Development • V - SERVICE STATIONS 19.32.160 Surrounded by Commercial or Industrial Zones Where service stations are located across the street from or abut commercial or industrial zones, the following requirements are applicable: 1. One freestanding, lighted, double-faced identification sign not exceeding 150 square feet for the total of all faces with no one face exceeding 75 square feet is permitted. Such sign shall not exceed a height of 35 feet. The sign shall be lighted only during business hours. 2. One sign mounted on an exposed building face is permitted for each street frontage and shall not exceed 20% of the exposed building face area to which it is attached. Such face -mounted signs may be illuminated. 3. Two unlighted double-faced signs not exceeding 20 square feet per face are permitted. Such signs shall be non-portable and may be used for advertising copy customarily displayed in service stations. 4. In addition to the above regulations, the following signs are allowed without permit: a. Signs at each pump island denoting the type of fuel, price and service available, providing such signs are permanently mounted to pumps or pump island structures. b. Signs on roll -away type racks advertis- ing merchandise in such racks. Examples include tire racks, batteries, bulk oil sales, etc. Such signs are limited to two square feet. (Ord. 1274 §1(part), 1982) VI - INDUSTRIAL ZONES 19.32.170 Permitted Signs - Height Signs shall be as described under TMC 19.32.140, except that height of a freestanding sign permitted for the first ten acres is 45 feet. (Ord. 1274 §1(part), 1982) VII - FREEWAY INTERCHANGE BUSINESSES 19.32.180 Permitted Signs - Height and Area Allowance The maximum allowed message area for a freeway interchange business sign is 125 square feet per face or a total of 250 square feet for all faces of the sign. The minimum height allowed for a freeway interchange business sign shall be 35 feet and the maximum height shall be 125 feet. The minimum and maximum height for a freeway interchange sign includes any and all message areas attributable to the business the sign advertises. No portion of the message area, including logos, text or other advertisements, for the freeway TITLE 19 — SIGN CODE interchange sign may be located below 35 feet on the freeway interchange business sign. (Ord 1892 §6, 1999; Ord. 1274 §1(part), 1982) VIII - HOTELS 19.32.190 Signs Mounted on Hotel Building Faces A. Each hotel shall be permitted one building face - mounted sign on each building face of the hotel, which sign shall contain only the hotel name and/or logo. The area of each building face -mounted sign shall be as provided in Table 1 of TMC 19.32.140A. A hotel may not have more than four building face -mounted signs, except as provided in TMC 19.32.190B. For the purpose of this subsection, "building face" shall be defined as provided in TMC 19.08.060, without the limiting requirements of subsections 1, 2 and 3 thereof. B. If a hotel has a restaurant operation which is located in the hotel building, then the hotel shall be permitted one additional exposed building face - mounted sign within the area as provided in Table 1 of TMC 19.32.140A; provided, that the sign is placed on the ground floor of the exposed building face and identifies only the restaurant name. C. A hotel shall be permitted freestanding and internal information signs as provided in TMC 19.32.140D and TMC Chapter 19.22, respectively. (Ord. 1274 §1(part), 1982) IX— VIDEO DISPLAYS 19.32.200 Video Displays at Sports Stadiums Scoreboards as permitted by TMC 19.12.050 (17) are permitted to have a video display, provided they meet the following requirements: 1. The scoreboard and the video display must be a single integrated structure. 2. Video displays are only permitted at sports stadiums that have a seating capacity of at least 2,000 persons or greater. Such stadiums must be located in the LDR zone and have a Public Recreation Overlay. 3. Only one scoreboard with video display is permitted per field. 4. The video display may only be used between the hours of 8:OOAM and 11:OOPM. 5. The entire scoreboard with video display cannot exceed 200 square feet. 6. The scoreboard with video display must face away from the public rights-of-way, public trails, adjacent properties, and water bodies. The video display must have minimal visibility from adjacent properties, public rights-of-way, and public trails. The video display cannot have a negative impact on the quiet enjoyment of surrounding residential properties, as determined by the Director of the Department of Community Development. Printed July 2006 Page 19-17 Chew Tani Chswon ilmage Refresh P©jccff SITE PL LEGEND Station Aerial Photo Chevron ID Sign (reface only) �5�•� Chevron Wordmark Channel Letter Set p,,) -2 Chevron Hallmark Logo No Change to Existing Extra Mile Sign Blue LED Down Lighting. 0- Blue LED Accent Lighting Gvc)(,-( Chevron Gas Station 15060 Tukwila Int'I Blvd Tukwila, WA 98188 52nd St Station Location 7t: ECEDVED R a8EN /g7z1/) ogo His.-08pafiDf Not fust a Sign company anymoreli PHYSICAL ADDRESS: 325 Burnett Ave N Renton, WA 98057 MAILING ADDRESS: PO BOX 2849 Renton, WA 98056 PHONE: (425) 917-2109 FAX: (425) 917-0153 Customer: &_71u. RTA�O'" CON9JLTN6 GROUP LLC Cheuvon Page: 1 OF 5 PROJECT ADDRESS: 15060 Tukwila International Blvd TUKWILA, WA DATE: 3/17/08 Contact: Steven Thomson Steven@insigniasign.com Parcel #0041000680 Job #08-3546 Zone: RC This is an original design and drawing created for the exclusive use of the customer. Until transfer by sale, all rights are reserved and it is only to be used by customer in connection with this project. It is not to be reproduced in any manner without the express written approval of Insignia Sign, Inc. Construction or permitting conditions may cause a change in dimensions or specifications. 002 to tFoo Writhe Pteaes& a¢ars say vont 1111\-\1/9t Project Scoae of Work *Replace existing ID sign faces with new Chevron Image Refresh faces as shown on elevation drawing, page 3. *Replace existing Chevron Wordmark canopy sign on west canopy fascia per specs & scope of work on elevation drawings, page 4. e*Replace existing Chevron Hallmark canopy sign on south canopy fascia per specs & scope of work on elevation drawing, page 5. *No change to existing Extra Mile Sign. ®*Install new Chevron blue LED down - lighting on the west canopy fascia per specs & scope of work on elevation drawing, page 4. *Install new Chevron blue LED accent lighting under bottom cap on the north & south canopy fascias per specs & scope of work on elevation drawing, page 5. • • • • • • • • • • • • • • Ltg_ OF 444. vitt IF' w► if;. Property Line = -280' 22' 4trA6 ' /�DG • r3r 4-9 ERANC�C • 4 INTERSECTION , S152nd--St Property Line = -260' •a3ueia;u3•peieWg- �N \ cc 11 a J� Property Line = -70' RECEIVED MAR 181008 !t,ri iA- I3EVEW.i.?I! PiT 1 SCALE: 1" = 30' //VS/GN//i Sign & Re -Imaging Not just a aign company anymore.0 PHYSICAL ADDRESS: 325 Burnett Ave N Renton, WA 98057 MAILING ADDRESS: PO BOX 2849 Renton, WA 98056 PHONE: (425) 917-2109 FAX: (425) 917-0153 Customer: 41- UELT 9:" ��' coNsu�mma Qaouv ��c Chevron Page: 2 OF 6 PROJECT ADDRESS: 15060 Tukwila Intemational Blvd TUKWILA, WA DATE: 3/17/08 Contact: Steven Thomson Steven@insigniasign.com Parcel #0041000680 Job #08-3546 Zone: RC This is an original design and drawing created for the exclusive use of the customer. Until transfer by sale, all rights are reserved and it is only to be used by customer in connection with this project It is not to be reproduced in any manner without the express written approval of Insignia Sign, Inc. Construction or permitting conditions may cause a change in dimensions or specifications. One to the pig process, colors may Vi% [Qj Sign "A" Elevation SCALE: 1/2" =1' Existing Chevron ID Sign Sco • e of Work *Remove & discard existing ID Sign Faces. *Install new Chevron Image Refresh Faces (Hallmark Logo, 3 -Product LPS Price & Diesel). *No change to existing Extra Mile Sign. *No change to existing brick base. *Total Sign Height = 131/2' (no change). *Total Sign Square Feet = 53.5 (no change). *Set -Back from Property Line =14' from S 152nd St (no change). =19' from Tukwila Int'I Blvd (no change). 12" 010 010 OW= OWN Ell WO. ■—. -- Ewa ■ -- • — MUM IIII MM. II III II — .—. III — .—. .-- ■—■ NM— .UM. INN MI • MIR .-M1. -- ■—■ -- ■—■ M ►i -O— ■N■ NMI — ■ IMO ■ —I MN III New Chevron Hallmark faces New Chevron Price faces Existing Extra Mile Cabinet & Faces (no change) Imam Existing brick base —_ (no change) ----------5 8" ---u------®- * (•—®--------® 7772S1 RECEIVED MAR 18 COMMUNtTy 'I i'; l/1115/DYWA ign & Re -Imaging Notfust a Sign company anymore.! PHYSICAL ADDRESS: 325 Burnett Ave N Renton, WA 98057 MAILING ADDRESS: PO BOX 2849 Renton, WA 98056 PHONE: (425) 917-2109 FAX: (425) 917-0153 Customer: RTA�O'" 'TT' CON97LT1N6 GROUP LLC Chevron %10 Page: 3 OF 5 PROJECT ADDRESS: 15060 Tukwila International Blvd TUKWILA, WA DATE: 3/17/08 Contact: Steven Thomson Steven@insigniasign.com Parcel #0041000680 Job #08-3546 Zone: RC This is an original design and drawing created for the exclusive use of the customer. Until transfer by sale, all rights are reserved and it is only to be used by customer in connection with this project. It is not to be reproduced in any manner without the express written approval of Insignia Sign, Inc. Construction or permitting conditions may cause a change in dimensions or specifications. Due to the Wadi* per. colors nsay v U Sign "B" West Elevation SCALE:¢118»=1 4 Canopy Facia Square Footage = 339.5 97' 1 REI New Blue LED Down -Lighting Installed under Top Cap. (©) set New Bristol Blue Canopy Facia with White End & Top Caps. New White Chevron 24" Wordmark illuminated letters Existing Canopy Sign Sign "B" Scope of Work *Remove & discard existing Chevron canopy mounted channel letters sign. *Install new 24" Chevron Wordmark Letter sets (illuminated with white neon) centered top to bottom and spaced from canopy edge as shown. *Wire signs to existing electrical circuit. *Total Square Footage = 21 each (*no change*) *Approximate Total Weight = 5# per letter. NOTE: See Attached Sheet for Specifications of Lettere. Mounting Details. Installation & Electrical Information. DI Blue LED "E" Scope of Work *Install new blue LED down lighting under top canopy cap on west elevation of canopy. *Wire LED to existing electrical circuits. 1 Mounting Details for Chevron Workmark Channel Letters .s0e6100 Wmrm 61.6 OS• -6 6 M SOLI 11VLIN CI C169/616, SC26. /aft 0CMOCOCTS01 ittaf OM M .0.4. 60 0, 006065 SG6 e.On 6 �7O 10' 5i' R TUBESUP w/P NE0 CONNECTOR & STRAIN RELIEF BOOT CONDUIT .06.3 ALUM. BACK •1/4" THREADED WE w/LIGHT P 1" ' ACER ACTUAL SO. FT. = 8.8 STD TRANS. BOX TRANSFORMER .040 ALUM. RETURNS TUBESUPPORT w/PAD NE CONNECTOR & STRAIN RELIEF BOOT CONDUIT .063 ALUM. BACK rSUPPLY DISCONNECTS 01/4" THREADED {SWITCH -STD TOGGLE: ROO (LOOSE) j WEEP HOLE w/UGIT BAFFLE 1/4' SPACER MOUNTING OPTIONS CLCMS &Valet"Nil EOLIVIIENT GROUNDED CLEQUIPMENT CROSsmisrisovMOUNDED cial mOUNT1 4 BACK. K. .063 ALUM. RETURN: 5.8011.040 ALUM. PAINTED METALLIC SILVER INSIDE OF CL PAINT WHITE FACE: .125 7328 WHITE ACRYUC JEWEUTE: 1' PAINTED METALLIC SILVER NEON: 15mm 6500 WHITE GENEMINIMUM 18 SHEET METAL SCREWS ARE TO 8E USED FOR SECURING THE FACE TO THE LETTER RETURN. THE MAXIMUM SPACING SHALL NOT EXCEED 18" ANO NO FEWER THAN FOUR SCREWS ARE TO BE USED PER FACE. TUBE SUPPORT (NEON 6 TIED TO TUBE SUPPORT COPPER WIRE. SHELLAC 6 APPLIED TO EACH WIRE TIE TO PREVENT LOOSENING OF THE WIRE.) STD TRANS. 80X TRANSFORMER rSUPPLY DISCONNECT -1 SWITCH -STD TOGGLE: (LOOSE) j FI FCTRICAI _NOTF-Actuol of circuits to be determined by 0 UCENSED ELECTRICAL CONTRACTOR. TOTAL AMPS: 7 / OF CKTS: 1 20 AMP(RECOMMENDED) VOLTS: 1 7n ALL SIGNAGE WILL 8E (U.L) L6TED, (U.1.) 2161 COMPU NT AND CARRY (U.L) LABELS. to 1.p 66[ 1 • MN. PM AA_ 101 IT 011 wa• llmAa 1.1NE LNECTDR -Sul! DE RESPONSIBLE FOR DETERIONPG F HALL CONCHICHS ARE AOEOUATE FOR LETTER INSTALLATIONS ARID 06504IN6 ACTUAL ATTACHMENT. F REQUIRED, MOTIONAL SUPPORT MEMBERS SHOULD BE ERECTED PRIOR TO RGT NATION. 2. LAYOUT DWENSONS SHORN ON THIS DRAWING ARE FOR SPACING VER61Ci TON ONLY. BUDDING LETTERS TO BE INSTALLED USING FULL SIZE PATTERNS. 3. IACRATE LETTERS SOON AFTER RECEIPT TO 8E SURE NO 010140E HAS OCCURRED. F LETTER 15 OANAGED, FRE A CONCEALED DAMAGE REPORT rani DELIVERY COYPANF. THIS KIST BE DONE WmmN 7 DAYS. 4. THE R1p0CW(. LETTERS ARE TO BE MOUNTED ON vERTCAL CANOPY FASCIAS OR RALIS. 5. A MOUNTING PATTERN 6 FURNISHED ROH THE LETTERS WHICH THE LOCATETHE HOLATTING HOLES AND ELECTRx NHOLES HN HOING SURFACE. TO � AND MARX ALL AATTARE LETTERS CIWENTT HOLES. BE .TAPE PATTERN 7. DRILL HOLES THROUGH RASA AREAS FOR TYPE OF FASTENERS TO BE USED. 8 REMOVE LETTER FACES wax TRW CAP. IDUNT LETTER TO WALL, PULL ELECTRICAL FRO/ REMOTE TRANSFORMER AND CONNECT TO ELECTRICAL SHORT STOP CONNECTOR. TEST LIGHT LETTERS AFTER ALL ARE HOMED. 9. REPLACE LETTER FACES AND CLEAN UP AREA com 35(1.- C 0 wRE (scu.nort T ((1 xcs) 1//26 SEALTIGNR CONNECTORS LAPELECIROTCBH7OCKNuT TOP CONNECTOR 7- ENO CAP 7- STRAIGHT PCS. (1)- D6CONRNECT SWITCH (25) - 1 1/2- LNG PVC SPACERS _ __(_ 7 SRNE OF TRAL6 80x) (25) -)(" x 18- LG. THREADED ROD R6TALIATON DRAwu W/ (2) N11T5 & WASHERS EACH CUMMINGS SIGNS. 11.46 • •00/03 NUJ.N.a64 CHEVRON PRESENTATION 2-0 RAT ' MEVRON' CL - 60,14 WHIT FACES - SILVER RETURNS is 16 itwouctou 10/27/02 yr 061 (NE6 SITU') a 0 ', J wFLL� uW IC uIES � ULOID CrrNaa�HV39701 ifnt vow/ 106 - J RECEIVED NAR 1 e 2000 COMMUNITY v 1I ArAlAcA T /N5/GN//q sign & Re -Imaging Notfust a Sign company anymore!./ PHYSICAL ADDRESS: 325 Burnett Ave N Renton, WA 98057 MAILING ADDRESS: PO BOX 2849 Renton, WA 98056 PHONE: (425) 917-2109 FAX: (425) 917-0153 Customer: 4.17-„NFTTAIDC:rCON9JLTIItLLC Chevron Page: 4 OF 5 PROJECT ADDRESS: 15060 Tukwila International Blvd TUKWILA, WA DATE: 3/17/08 Contact: Steven Thomson Steven@insigniasign.com Parcel #0041000680 Job #08-3546 Zone: RC R This is an original design and drawing created for the exclusive use of the customer. Until transfer by sale, all rights are reserved and it is only to be used by customer in connection with this project. It is not to be reproduced in any manner without the express written approval of Insignia Sign, Inc. Construction or permitting conditions may cause a change in dimensions or specifications. Due to the printing proem. cobrs may vary. Sign "C" South Elevation eame ae (x) 29" (x)J-- 22' Canopy Facia Square Footage = 77 o- 1 New Chevron Hallmark illuminated Logo 1 !r La 1 BOJ co Si • n "C" Scope of Work *Remove and discard existing Chevron Logo Sign. *Install new 25" Chevron Hallmark Logos illuminated with white neon centered top to bottom and spaced from canopy edge as shown. *Wire sign to existing electrical circuit. *Total Square Footage = 5 sf. *Approximate Total Weight= 5#. New Pearl White Canopy Facia with White End Caps. New Blue LED lighting installed Cap.( om Cap.( Blue LED "F" Sco • e of Work *Install new blue LED accent lighting under bottom canopy cap on south elevation of canopy. *Wire LED to existing electrical circuits. Existing Canopy Sign Mounting Details for Chevron Hallmark Logos 7, J Internally Illuminated pin mount channel letters with neon illumination. Aluminum Passthru thru 718" da. hole in wall Metal greenfield High-voltage connector in gang box Metal greenfield from other units Metal greenfield to other units GTO covering or sleeving GTO sleeve Pin Mount t- off fascia with stainless steel studs & hardware .063' Aluminum Backs & 040" Aluminum Retums painted i blue to match PMS 2935 and �� red to match PMS 186 N\... 60 mitiamp transformer in box Metal greenfield 1" 5" 1" Pin -Mounted Electrobits-Insulator-System Remote -Transformer Illuminated Channel Letter 1" Trimcap retainer painted blue to match PMS 2935 and red to match PMS 186 3/16" Plexiglas letter faces with gradient item applied 13mm White luminous neon tubing Tube support End Cap GTO covering or sleeving RECEIyED MAR 1 &2008 COMMUNITY V L ♦ k -V r .iwru t /NS/GN//) Sign & Re -Imaging Not juat a sign company anymoreli PHYSICAL ADDRESS: 325 Burnett Ave N Renton, WA 98057 MAILING ADDRESS: PO BOX 2849 Renton, WA 98056 PHONE: (425) 917-2109 FAX: (425) 917-0153 Customer: RTA�O'" CON9JLTIN6 GD LLC Chevron Page: 5 OF 5 PROJECT ADDRESS: 15060 Tukwila Intemational Blvd TUKWILA, WA DATE: 3/17/08 Contact: Steven Thomson Steven@insigniasign.com Parcel #0041000680 Job #08-3546 Zone: RC This is an original design and drawing created for the exclusive use of the customer. Until transfer by sale. all rights are reserved and it is only to be used by customer in connection with this project. It is not to be reproduced in any manner without the express written approval of Insignia Sign, Inc. Construction or permitting conditions may cause a change in dimensions or specifications. Dae to the printfny process. colors may vary. uL.v-InrefriL rnternz - l..ummings - i3bVU U1 A - 3' 6 X /' 6 EM BUILDING SIGN. df c1 Go 111"1111rAMPTIOPNWOMl 100.PoP4M-Inritazi u.4Y%turtl C.ualreJ'catf.P1elm INned w.118 mstssalL&Ocsr isAtMlto 3/D4.ti odgia.= f1II - Fits..s T_14n.u.ayaL CUtt1111111r}a l C' Z Lti t" C Page 1 <. 2iG,c: C" ISYS i9 n No 3-341.11'15" scala 1111-4,-" pato 5-4.A.0-5 Crwtad for thy approval of: r NriliciO0/ TNI! )=.LQV ?FV A N? CIIR F1:I t' I VF PQPFRTV AVn VANN02 OOI'LA;Aire W TNf`JT W11TTCV1.:nhX.ChT Thi. In hrnryit rNi!iron rvir. Drawn by- r htiI�CE