Loading...
HomeMy WebLinkAboutPermit S08-031 - AT&TAT&T 344 SOUTHCENTER MALL S08-031 BUILDING MOUNTED SIGN • SITE INSPECTION (PLANNING) File No. S08-031 Name of Tenant: AT&T Sign Address: 344 Southcenter Mall Date Photo Taken: October 9, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-09-08 City (IP Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 6364200010 Address: 344 SOUTHCENTER MALL TIIKW Suite No: Permit Number: S08-031 Issue Date: 05/16/2008 Permit Expires On: 11/12/2008 Business: Name: AT&T Address: 344 SOUTHCENTER MALL , TUKWILA WA Phone: Property Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 Contact Person: Name: JOHN WEISS Phone: 425-501-6447 Address: 4009 139TH PL SE Contractor: Name: NEON SYSTEMS Phone: 425-501-6447 Address: 4009 139TH PLSE DESCRIPTION OF WORK: 1 wall sign for AT&T at the mall. A s2nd sign is not anticipated to be discernable from the ROW and won't require a permit unless it is discernable and then it would need to meet code. SM Fees Collected: $125.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 427.5 0 0 0 Wall Sign Size (sq. feet): 16.2 0 0 0 Sign Lighting: Face Residential Land: Freestanding Sign #1 Street Frontage for Entire Lot: 0 Building Height (feet): 0 Sign Size (sq. feet): 0 Sign Height (feet and inches): 0 ' 0 " Setback (feet): Number of Sign Faces: 0 Freestanding Sign #2 0 0 0 0' 0" 0 0 0 Planning Division Authorized Signature. Date: 5-i(0--01, I hereby certify that I have read and examined t'► permit and kit w the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM !1G 1 G n/V10 SOS -031 Printed: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-031 Address: 344 SOUTHCENTER MALL TURIN Status: PENDING Suite No: Applied Date: 04/11/2008 Applicant: NEON SYSTEMS INC Issue Date: Receipt No.: R08-01143 Payment Amount: $125.00 Initials: SM Payment Date: 04/11/2008 11:09 AM User ID: 1166 Balance: $0.00 Payee: John Weiss for Neon Systems TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 125.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 125.00 Total: $125.00 1076 04/11 0711 TOTAL 125=00 rinr. Rar.Pint-(lfi Printed: f14-11-9(1(18 City" Tukwila RCS De art of Community Develo ment NO. �7✓ �C�3 p P 6300 Southcenter Boulevard, Suite 100 8 beer 4 (0% Tukwila, Washington 98188 COMMuNfTv 206 431-3670 mfft,CIPNIENT PERMANENT SIGN PERMIT APPLICATION Business Name Z-10 GOE4SS Applicant/Contact gid,/(( ,S/$.ke iofr Contractor Please print 3 Celt mn4441 Address of Sign !otq /31'11/ PC 5.E. Address, City, State, Zip x'009 13q1FP7- s.E Address, City, State, Zip Phone `12$ vrb1-6557 Phone Phone CHECKLIST ❑ 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs ❑ Sign elevations with area calculations and dimensions ❑ Building elevations (for wall signs) ❑ Supporting structure and method of illumination ❑ One copy of valid Washington State contractor's license ❑ $125 application fee per sign See back of form for examples Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? 0 Yes 0 No Wall 2 WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) 4 27 5 16 2 ,S Sign size(square feet) 21.1'3 21,33 Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. Does wall sign weigh more than 400 pounds?(Y/N) Sign illumination (intemal/external/none) FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of si • n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila vyjll.bp met. 11--10 de Date (Si ature of owner or authorized agent) Email Address FOR OFFICE USE ONLY Zoning: Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions P:\Planning Forms\Applications\2007 Applications\PermSign-12-07.doc Revised on 12-07 • Sign Area is calculated by constructing.a polygon. around the sign using right angles. Big Store 23'-9" Frontage Building Elevation Wall Area is calculated by multiplying the length and height of the tenant space. Footing Detail t .....II Me,. a.tios •••• irs •••• Q;...... Wall Mount Detail For all wall mounted signs over 400 pounds. Tenant Space Site/Leasing Plan N--> niog r • Existing Sign I.-1iiii11iiiiiilllliiii Property Lines —7l Street Frontage Site Plan Show applicant space and all existing and proposed signs. For freestanding signs show the length .of frontage nn niII ni iI Jir• ctrnntc Rl-Revuedmx ing pls LLnotes. ddtted score Iwurs from doorvinyl_-03.14.o&sv R2-RerrseA sigrtg02fo maa'L5s7.R'-05115'g4.sG' "`✓' \. 8'-1 Y2" 1 1/4" THICK ROUTED PLEX LETTERS PLEX BLOCKS SLOAN MINI WHITE LEDS MINI WHITE LED WIRING 002 SCALE: 1/2°"=1'-0" SQ. FT: 21.75 NOTE: Signage contractor is responsible to insure that signage is connected to a separate circuit and on 7 day time cloc et mall's operating hours. LIF-BLK-32-H- REVERSE PAN LETTERS/CUSTOM ACRYLIC GLOBE MANUFACTURE AND INSTALL ONE (11 SET OF HALO -ILLUMINATED, ALUMINUM. REVERSE CHANNEL LETTERS AND POCKET RO t', GLOBE: FCO'S OVERLAY: 1 1/4" TICK CLEAR PLEX WITH A POCKET ROUTED REVEAL. PAINTED BLACK AS A BLOCK OUT AND THEN FINISHED WHITE. DO NOT PAINT BACK AND REVEAL, FACES & RETURNS: 1 1/4" POCKET ROUTED PLEX . MASK AREAS UNDER PAINTED FIRST BLACK TO BLOCK OUT LIGHT AND FINISHED TO MATCH MATTHEWS #00909 AT&T BLUE. (NOTE: 00 NOT PAINT INSIDE) BACKS: TO BE .177" #2447 WHITE DIFFUSER PLEX. • ILLUMINATION: LED LIGHT SOURCE BY SLOAN MINI -WHITES AS REQUIRED FOR PROPER EVEN ILLUMINATION. AT&T: FACES & RETURNS: .1 1/4" TICK CLEAR PLEX WITH A POCKET ROUTED REVEAL. PAINTED BLACK AS A BLOCK OUT AND THEN FINISHED WHITE. BACKS: TO BE .177" #2447 WHITE DIFFUSER PLEX. ILLUMINATION: LED LIGHT SOURCE BY SLOAN MINI -WHITES AS REQUIRED FOR PROPER EVEN ILLUMINATION. 15/8" SPAC 3/8" ALL -THREAD THROUGH WALL REMOTE SLOAN WATERPROOF -60 POWER SUPPLY TOGGLE DISCONNECT SWITCH (TYP.) 10 U.L. APPROVED INSTALLATION DETAIL LED HALO LIT REVERSE PAN PLEX LETTER • 1 1/2"=1'-0" RYLIC, REVERSE CHANNE \\o(1 ni i7..CY.ko5 - 68 2 9 NOTE: Locate all remote power sources where accessible for servicing yet not visible to public LOBE STAINLESS STEEL COUNTERSUNK BACKING LETTER FASTENER (TYP.) 1.25' FCO PLEX LOGO STRIPES. ATTACHED TO LOGO BACKGROUND WITH BRASS PRESS FR INSERTS AND 10-24 SCREWS AS NEEDED e SLOAN MINI LED'S 3/8' DIA. 0.0. ALUM. TUBING AS ELECTRICAL CONDUIT TACK ED TO A CAM CUT MOUNTING BRACKET. 3/8' DIA. 0.1). ALUM. TUBING AS A CRASH SPACER (TYP. OF MIN. 4 PER LETTER) ALUM. STUD ATTACHED TO LETTER WITH TYPICAL BRASS PRESS-FIT INSERTS PREVIOUSLY ATTACHED INTO A POCKET ROUT OUT OPENINGS AT BACK OF LETTERS. .118' THICK WHITE DIFFUSER LETTER BACKING. 20 U.L. APPROVED INSTALLATION DETAIL LED HALO LIT REVERSE PAN PLEX LETTER • NOT TO SCALE" 1 c\ c, \ Signtech- 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527.6100 I Fax: (619) 527.6111 www.signtechUSA.comte{� at&t Mobility 344 Southcenter Mall Westfield Southcenter Seattle, WA 98188 Date 01/25/08 Salesperson' Arthur Navarro Coordinator Christine Mello Designer Svetlana Mladenov Scale. As Noted Revisions 05.15.08-sv A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech Goes NOT provide primary electrical to sign location - RESPONSIBIUTY OF OTHERS! Customer Signature Date Thisdesign is the exclusive properly of Signtech ad cannot be reproduced in whole or in pan, without their prior written approval. Drawing Number: 08-00190 Sheet: 5 Or: 6 R2 3q'-/ liaSouthcenter Mall Westfield Southcenter Seattle, WA 98188 �icjntec hM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 5274100 / Fax: (619) 527-6111 www.signtechUSA.com RECEIVED APR 11 2008 COMMUNITY DEVELOPMcUT MEMBER :o A III114111111 MUM 11131.381 gm; � at&t Mobility 633 Southcenter Mall Westfield Southcenter Seattle, WA 98188 Date 01/25/08 Salesperson Arthur Navarro Coordinator Christine Mello Designer Svetlana Mladenov scale. As Noted A D A A ;,Revisions A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONS!B!L!TY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00190 Sheet: 1 Of : 5 SITE PLAN. N.T.S. t. .I ION Ell Fel Recommendations Report Zone Sign# Sign Type Description Exterior 001 LIF-BLK-32-H Reverse pan letters with custom acryiic globe 002 LIF-BLK-32-H Reverse pan letters with custom acrylic globe 003 V-1 Window Vinyl - Store Hours - White Letters - 3.8" Globe - 0.43x 004 V-1 Window Vinyl - Store Hours - White Letters - 3.8" Globe - 0.43x s o p s z RECEIVED APR 11 2008 COMMUNITY DEVELOPMENT Signt¢chm 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 5274100/ Fax: (619) 5274111 www.signtechUSA.com 0 1111M1 MEMBER A MM Manisa IRBABER tl� .=AiAt at&t Mobility 633 Southcenter Mall Westfield Southcenter Seattle, WA 98188 Date 01/25/08 Salesperson. Arthur Navarro Coordinator. Christine Mello Designer. Svetlana Mladenov scale. As Noted A A A 0 „Revisions 0 A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00190 Sheet: 2 Of: 5 EQ PROPOSED SIGNAGE EQ 10'-10" EQ 001 003 PROPOSED STOREFRONT ELEVATION SCALE: 1/16":=11-0" pROPOSED REAR OF STORE ELEVATION SCALE: 1/16"=1'-0" SIGN BEHIND GLASS STOREFRONT SECTION SCALE: 1/8"=1'-0" RFCEIV ED ' APR 11 2008 COMMUNITY DEVELOPMENT Signtech- 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 5274100! Fax: (619) 527.6111 www signtechUSA.com MEL®ER A MINION MOO= c at&t Mobility 633 Southcenter Mall Westfield Southcenter Seattle, WA 98188 Date 01/25/08 Salesperson Arthur Navarro Coordinator: Christine Mello Designer Svetlana Mladenov Scale. As Noted Revisions 0 0 0 A A O 0 CUSTOMER APPROVAL Customer Signature Date COPY COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00190 Sheet: 3 Of : 5 1'-4 7/8" 1'-4 7/8" 1'-4 1/4" 1'-41/4" ALL COPY TO BE WHITE VINYL 1 t/4" 1 3/8" 7/8" 3 7/8" 'axe COOECZ [glom=M 03000 00 Em =5:00 0o pml Seuuscla f 6000 00 agn 00:0 0 p i(r�if Sandmy a00 :000 am=4 0 300 pain ALL COPY TO BE WHITE VINYL Th Hours 8•00arri 1 OOpm 00pm 30 OOam-4' Opm r A.j SCALE: 1 1/2"= 11-0" MANUFACTURE AND INSTALL TWO (2) SETS OF WINDOW VINYL LARGE GLOBE LOGO: TO BE DIGITALLY PRINTED ONTO 3M DUAL COLOR FILM #3635-210 WHITE. SMALL GLOBE: TO BE DIGITALLY PRINTED ONTO 3M IJ -8171-10 WHITE. GLOBE TO BE PRINTED FULL COLOR 600 DPI. OVERLAMINATE WITH 3M #8914 CLEAR. ALL OTHER COPY: TO BE 3M FILM #7725-10 WHITE ALL TO BE APPLIED FIRST SURFACE. TYPICAL INSTALL SCALE: 3/4"=1'-0" PER LL SatibmN sugnage shop &awnings torr rrewnew anis apprrowal Signage nullsit ft on sepavee oirrcaou1I and on 7 day Unlo dock se to 0Ir DD9s opereong hoaorrs.( ) RECEIVED APR 11 2000 ti. rbhWP1 OMT 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 52741001 Fax: (619) 527-6111 www.signtechUSA.com MOAT MEMBER [MIN at&t Mobility 633 Southcenter Mall Westfield Southcenter Seattle, WA 98188 Date' 01/25/08 MEMBER OF Salesperson Arthur Navarro Coordinator. Christine Mello Designer Svetlana Mladenov Scale' As Noted 0 A 0 A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00190 Sheet: 5 Of: 5