HomeMy WebLinkAboutPermit S08-031 - AT&TAT&T
344 SOUTHCENTER MALL
S08-031
BUILDING MOUNTED
SIGN
•
SITE INSPECTION (PLANNING)
File No. S08-031
Name of Tenant: AT&T
Sign Address: 344 Southcenter Mall
Date Photo Taken: October 9, 2008
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of XX/XX/200X
Make new site visit and take photo by XX/XX/200X
Comments: Sign inspected and meets code. CT 10-09-08
City (IP Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
PERMANENT SIGN PERMIT
Parcel No.: 6364200010
Address: 344 SOUTHCENTER MALL TIIKW
Suite No:
Permit Number: S08-031
Issue Date: 05/16/2008
Permit Expires On: 11/12/2008
Business:
Name: AT&T
Address: 344 SOUTHCENTER MALL , TUKWILA WA
Phone:
Property Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940
Contact Person:
Name: JOHN WEISS Phone: 425-501-6447
Address: 4009 139TH PL SE
Contractor:
Name: NEON SYSTEMS Phone: 425-501-6447
Address: 4009 139TH PLSE
DESCRIPTION OF WORK:
1 wall sign for AT&T at the mall. A s2nd sign is not anticipated to be discernable from the ROW and
won't require a permit unless it is discernable and then it would need to meet code. SM
Fees Collected: $125.00
PERMANENT SIGN:
Zoning: TUC Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 427.5 0 0 0
Wall Sign Size (sq. feet): 16.2 0 0 0
Sign Lighting:
Face Residential Land:
Freestanding Sign #1
Street Frontage for Entire Lot: 0
Building Height (feet): 0
Sign Size (sq. feet): 0
Sign Height (feet and inches): 0 ' 0 "
Setback (feet):
Number of Sign Faces:
0
Freestanding Sign #2
0
0
0
0' 0"
0
0 0
Planning Division Authorized Signature.
Date: 5-i(0--01,
I hereby certify that I have read and examined t'► permit and kit w the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
doc: SIGN -PERM
!1G 1 G n/V10
SOS -031 Printed:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: S08-031
Address: 344 SOUTHCENTER MALL TURIN Status: PENDING
Suite No: Applied Date: 04/11/2008
Applicant: NEON SYSTEMS INC Issue Date:
Receipt No.: R08-01143 Payment Amount: $125.00
Initials: SM Payment Date: 04/11/2008 11:09 AM
User ID: 1166 Balance: $0.00
Payee: John Weiss for Neon Systems
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Cash 125.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
SIGN PERMIT
000/322.100 125.00
Total: $125.00
1076 04/11 0711 TOTAL 125=00
rinr. Rar.Pint-(lfi Printed: f14-11-9(1(18
City" Tukwila RCS
De art of Community Develo ment
NO. �7✓ �C�3
p P
6300 Southcenter Boulevard, Suite 100 8 beer 4 (0%
Tukwila, Washington 98188 COMMuNfTv
206 431-3670 mfft,CIPNIENT
PERMANENT SIGN PERMIT APPLICATION
Business Name
Z-10 GOE4SS
Applicant/Contact
gid,/(( ,S/$.ke iofr
Contractor
Please print
3 Celt mn4441
Address of Sign
!otq /31'11/ PC 5.E.
Address, City, State, Zip
x'009
13q1FP7- s.E
Address, City, State, Zip
Phone
`12$ vrb1-6557
Phone
Phone
CHECKLIST
❑ 3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
❑ Sign elevations with area calculations and dimensions
❑ Building elevations (for wall signs)
❑ Supporting structure and method of illumination
❑ One copy of valid Washington State contractor's license
❑ $125 application fee per sign
See back of form for examples
Is your sign a:
❑ Freestanding sign 15 or more feet in height
❑ Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
If any of the above are true, the application must go
through structural review.
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
❑ Construction details to describe the proposed foundation
or wall attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding
Did building go through design review? 0 Yes 0 No
Wall 2
WALL SIGNS:
#1
#2
#3
#4
Wall area (length x height) of the tenant space where the
sign will be mounted? (square feet)
4 27 5
16 2 ,S
Sign size(square feet)
21.1'3
21,33
Does sign face residential zones or public facilities? (Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
Does wall sign weigh more than 400 pounds?(Y/N)
Sign illumination (intemal/external/none)
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
Size of sign face (square feet). Structural review is required for pole signs with faces 30
square feet or more in area
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
Distance from closest edge of sign to property lines (feet). Generally, signs must be set
back from all property lines a distance equal to their height.
Number of si • n faces
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at
(206) 431-3670.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that
the applicable requirements of the City of Tukwila vyjll.bp met.
11--10 de
Date (Si ature of owner or authorized agent)
Email Address
FOR OFFICE USE ONLY
Zoning:
Planning review by:
O Denied
0 Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
O Denied 0 Approved 0 Approved with conditions
P:\Planning Forms\Applications\2007 Applications\PermSign-12-07.doc
Revised on 12-07
•
Sign Area is calculated by constructing.a polygon.
around the sign using right angles.
Big Store
23'-9"
Frontage
Building Elevation
Wall Area is calculated by multiplying the
length and height of the tenant space.
Footing Detail
t .....II Me,. a.tios •••• irs •••• Q;......
Wall Mount Detail
For all wall mounted signs
over 400 pounds.
Tenant Space
Site/Leasing Plan
N-->
niog r •
Existing Sign
I.-1iiii11iiiiiilllliiii Property Lines
—7l
Street Frontage
Site Plan
Show applicant space and all existing and proposed signs.
For freestanding signs show the length .of frontage
nn niII ni iI Jir• ctrnntc
Rl-Revuedmx ing pls LLnotes. ddtted score Iwurs from doorvinyl_-03.14.o&sv
R2-RerrseA sigrtg02fo maa'L5s7.R'-05115'g4.sG' "`✓' \.
8'-1 Y2"
1 1/4" THICK ROUTED
PLEX LETTERS
PLEX BLOCKS
SLOAN MINI WHITE LEDS
MINI WHITE LED WIRING
002
SCALE: 1/2°"=1'-0"
SQ. FT: 21.75
NOTE: Signage contractor is responsible to insure that signage is
connected to a separate circuit and on 7 day time cloc et
mall's operating hours.
LIF-BLK-32-H- REVERSE PAN LETTERS/CUSTOM ACRYLIC GLOBE
MANUFACTURE AND INSTALL ONE (11 SET OF HALO -ILLUMINATED, ALUMINUM. REVERSE CHANNEL LETTERS AND POCKET RO
t', GLOBE:
FCO'S OVERLAY: 1 1/4" TICK CLEAR PLEX WITH A POCKET ROUTED REVEAL. PAINTED BLACK AS A BLOCK OUT AND THEN FINISHED WHITE.
DO NOT PAINT BACK AND REVEAL,
FACES & RETURNS: 1 1/4" POCKET ROUTED PLEX . MASK AREAS UNDER PAINTED FIRST BLACK TO BLOCK OUT LIGHT AND FINISHED
TO MATCH MATTHEWS #00909 AT&T BLUE. (NOTE: 00 NOT PAINT INSIDE)
BACKS: TO BE .177" #2447 WHITE DIFFUSER PLEX.
• ILLUMINATION: LED LIGHT SOURCE BY SLOAN MINI -WHITES AS REQUIRED FOR PROPER EVEN ILLUMINATION.
AT&T:
FACES & RETURNS: .1 1/4" TICK CLEAR PLEX WITH A POCKET ROUTED REVEAL. PAINTED BLACK AS A BLOCK OUT AND THEN FINISHED WHITE.
BACKS: TO BE .177" #2447 WHITE DIFFUSER PLEX.
ILLUMINATION: LED LIGHT SOURCE BY SLOAN MINI -WHITES AS REQUIRED FOR PROPER EVEN ILLUMINATION.
15/8" SPAC
3/8" ALL -THREAD
THROUGH WALL
REMOTE SLOAN
WATERPROOF -60
POWER SUPPLY
TOGGLE DISCONNECT
SWITCH (TYP.)
10 U.L. APPROVED INSTALLATION DETAIL
LED HALO LIT REVERSE PAN PLEX LETTER • 1 1/2"=1'-0"
RYLIC, REVERSE CHANNE
\\o(1 ni i7..CY.ko5 - 68
2 9
NOTE: Locate all remote power sources where accessible for
servicing yet not visible to public
LOBE
STAINLESS STEEL COUNTERSUNK
BACKING LETTER FASTENER (TYP.)
1.25' FCO PLEX LOGO STRIPES. ATTACHED
TO LOGO BACKGROUND WITH BRASS PRESS
FR INSERTS AND 10-24 SCREWS AS NEEDED
e
SLOAN MINI LED'S
3/8' DIA. 0.0. ALUM. TUBING
AS ELECTRICAL CONDUIT TACK
ED TO A CAM CUT MOUNTING BRACKET.
3/8' DIA. 0.1). ALUM. TUBING AS A CRASH
SPACER (TYP. OF MIN. 4 PER LETTER)
ALUM. STUD ATTACHED TO LETTER
WITH TYPICAL BRASS PRESS-FIT INSERTS
PREVIOUSLY ATTACHED INTO A POCKET
ROUT OUT OPENINGS AT BACK OF LETTERS.
.118' THICK WHITE DIFFUSER LETTER BACKING.
20 U.L. APPROVED INSTALLATION DETAIL
LED HALO LIT REVERSE PAN PLEX LETTER • NOT TO SCALE"
1
c\
c, \
Signtech-
4444 Federal Blvd. San Diego CA 92102
Phone: (619) 527.6100 I Fax: (619) 527.6111
www.signtechUSA.comte{�
at&t Mobility
344 Southcenter Mall
Westfield Southcenter
Seattle, WA 98188
Date 01/25/08
Salesperson' Arthur Navarro
Coordinator Christine Mello
Designer Svetlana Mladenov
Scale. As Noted
Revisions
05.15.08-sv
A A
A
A A
A
CUSTOMER APPROVAL
Customer Signature Date
COPY, COLORS & SIZES
Signtech Goes NOT provide primary
electrical to sign location -
RESPONSIBIUTY OF OTHERS!
Customer Signature Date
Thisdesign is the exclusive properly of Signtech
ad cannot be reproduced in whole or in pan,
without their prior written approval.
Drawing Number: 08-00190
Sheet: 5
Or: 6
R2
3q'-/ liaSouthcenter Mall
Westfield Southcenter
Seattle, WA 98188
�icjntec
hM
4444 Federal Blvd. San Diego CA 92102
Phone: (619) 5274100 / Fax: (619) 527-6111
www.signtechUSA.com
RECEIVED
APR 11 2008
COMMUNITY
DEVELOPMcUT
MEMBER
:o
A
III114111111 MUM
11131.381 gm;
�
at&t Mobility
633 Southcenter Mall
Westfield Southcenter
Seattle, WA 98188
Date 01/25/08
Salesperson Arthur Navarro
Coordinator Christine Mello
Designer Svetlana Mladenov
scale. As Noted
A
D
A
A
;,Revisions
A
A
A
A
CUSTOMER APPROVAL
Customer Signature Date
COPY, COLORS & SIZES
Signtech does NOT provide primary
electrical to sign location -
RESPONS!B!L!TY OF OTHERS!
Customer Signature Date
This design is the exclusive property of Signtech
and cannot be reproduced in whole or in part,
without their prior written approval.
Drawing Number: 08-00190
Sheet: 1
Of : 5
SITE PLAN.
N.T.S.
t. .I
ION Ell
Fel
Recommendations Report
Zone Sign# Sign Type Description
Exterior 001 LIF-BLK-32-H
Reverse pan letters with custom acryiic globe
002 LIF-BLK-32-H Reverse pan letters with custom acrylic globe
003 V-1 Window Vinyl - Store Hours - White Letters - 3.8" Globe - 0.43x
004 V-1 Window Vinyl - Store Hours - White Letters - 3.8" Globe - 0.43x
s o p
s
z
RECEIVED
APR 11 2008
COMMUNITY
DEVELOPMENT
Signt¢chm
4444 Federal Blvd. San Diego CA 92102
Phone: (619) 5274100/ Fax: (619) 5274111
www.signtechUSA.com
0
1111M1
MEMBER
A
MM Manisa
IRBABER tl� .=AiAt
at&t Mobility
633 Southcenter Mall
Westfield Southcenter
Seattle, WA 98188
Date 01/25/08
Salesperson. Arthur Navarro
Coordinator. Christine Mello
Designer. Svetlana Mladenov
scale. As Noted
A
A
A
0
„Revisions
0
A
CUSTOMER APPROVAL
Customer Signature Date
COPY, COLORS & SIZES
Signtech does NOT provide primary
electrical to sign location -
RESPONSIBILITY OF OTHERS!
Customer Signature Date
This design is the exclusive property of Signtech
and cannot be reproduced in whole or in part,
without their prior written approval.
Drawing Number: 08-00190
Sheet: 2
Of: 5
EQ
PROPOSED SIGNAGE
EQ 10'-10" EQ
001 003 PROPOSED STOREFRONT ELEVATION SCALE: 1/16":=11-0"
pROPOSED REAR OF STORE ELEVATION SCALE: 1/16"=1'-0"
SIGN BEHIND
GLASS
STOREFRONT SECTION
SCALE: 1/8"=1'-0" RFCEIV
ED
' APR 11 2008
COMMUNITY
DEVELOPMENT
Signtech-
4444 Federal Blvd. San Diego CA 92102
Phone: (619) 5274100! Fax: (619) 527.6111
www signtechUSA.com
MEL®ER
A
MINION MOO=
c
at&t Mobility
633 Southcenter Mall
Westfield Southcenter
Seattle, WA 98188
Date 01/25/08
Salesperson Arthur Navarro
Coordinator: Christine Mello
Designer Svetlana Mladenov
Scale. As Noted
Revisions
0
0
0
A
A
O
0
CUSTOMER APPROVAL
Customer Signature Date
COPY COLORS & SIZES
Signtech does NOT provide primary
electrical to sign location -
RESPONSIBILITY OF OTHERS!
Customer Signature Date
This design is the exclusive property of Signtech
and cannot be reproduced in whole or in part,
without their prior written approval.
Drawing Number: 08-00190
Sheet: 3
Of : 5
1'-4 7/8"
1'-4 7/8"
1'-4 1/4"
1'-41/4"
ALL COPY TO BE
WHITE VINYL
1 t/4"
1 3/8"
7/8"
3 7/8"
'axe COOECZ
[glom=M 03000 00 Em =5:00 0o pml
Seuuscla f 6000 00 agn 00:0 0 p i(r�if
Sandmy a00 :000 am=4 0 300 pain
ALL COPY TO BE
WHITE VINYL
Th Hours
8•00arri 1 OOpm
00pm
30 OOam-4' Opm
r
A.j
SCALE: 1 1/2"= 11-0"
MANUFACTURE AND INSTALL TWO (2) SETS OF WINDOW VINYL
LARGE GLOBE LOGO: TO BE DIGITALLY PRINTED ONTO 3M DUAL COLOR FILM #3635-210 WHITE.
SMALL GLOBE: TO BE DIGITALLY PRINTED ONTO 3M IJ -8171-10 WHITE.
GLOBE TO BE PRINTED FULL COLOR 600 DPI. OVERLAMINATE WITH 3M #8914 CLEAR.
ALL OTHER COPY: TO BE 3M FILM #7725-10 WHITE
ALL TO BE APPLIED FIRST SURFACE.
TYPICAL INSTALL SCALE: 3/4"=1'-0"
PER LL
SatibmN sugnage shop &awnings torr
rrewnew anis apprrowal Signage nullsit ft
on sepavee oirrcaou1I and on 7 day Unlo
dock se to 0Ir DD9s opereong hoaorrs.( )
RECEIVED
APR 11 2000
ti. rbhWP1 OMT
4444 Federal Blvd. San Diego CA 92102
Phone: (619) 52741001 Fax: (619) 527-6111
www.signtechUSA.com
MOAT
MEMBER
[MIN
at&t Mobility
633 Southcenter Mall
Westfield Southcenter
Seattle, WA 98188
Date' 01/25/08
MEMBER OF
Salesperson Arthur Navarro
Coordinator. Christine Mello
Designer Svetlana Mladenov
Scale' As Noted
0
A
0
A
Revisions
A
A
A
A
A
CUSTOMER APPROVAL
Customer Signature Date
COPY COLORS & SIZES
Signtech does NOT provide primary
electrical to sign location -
RESPONSIBILITY OF OTHERS!
Customer Signature Date
This design is the exclusive property of Signtech
and cannot be reproduced in whole or in part,
without their prior written approval.
Drawing Number: 08-00190
Sheet: 5
Of: 5