HomeMy WebLinkAboutPermit S08-036 - BORDERSBORDERS 2437 SOUTHCENTER MALL BLVD S08-036 BUILDING MOUNTED SIGN SITE INSPECTION (PLANNING) File No. S08-036 Name of Tenant: Borders Sign Address: 2437 Southcenter Mall Date Photo Taken: July 24, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CB 07.24.08 • • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director MEMORANDUM To: Connie Guffey for Plumb Signs From: Stacy MacGregor Re: Borders/SBC at Westfield Southcenter Date: 5-15-2008 Connie, I have approved a total of two "Borders" signs; one facing south and one facing west. I have also approved two "Seattle's Best Coffee" signs; one facing south and one facing west. North Face: 5074 SF EBF 6%: 304.4 SF allowed Borders sign: 121.7 SF SBC sign: 5.67 SF Total signs: 127.37 SF West Face: 6%: Borders sign: SBC sign: Total signs: 3159 SF EBF 189.5 SF allowed 119.3 SF 12.75 SF 132.05 SF As we talked about previously, I cannot issue a permit for the third "Borders" sign located under the pedestrian bridge. It does not meet the Tukwila Municipal Code. However, if the sign will not be discernible from the public right of way (Strander Boulevard and Southcenter Parkway) a permit is not required to install the sign. With the pedestrian bridge still under construction, I cannot confirm if the sign will be discernible or not. If you choose to install this sign and it is discernible, it will need to be removed. Call me if you have any questions at 206-433-7166. Thanks, Stacy M. eregor Assistant Planner Department of Community Development City of Tukwila V2N-Ls, mss Sc3-0LII 6300 Southcenter Boulevard. Suite #100 • Tukwila. Washington 98188 • Phone: 206-431-3670 • Fax: 206-4.31-3665 City ATukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 6364200010 Address: 2437 SOUTHCENTER MALL TUKW Suite No: Permit Number: S08-036 Issue Date: 05/15/2008 Permit Expires On: 11/11/2008 Business: Name: BORDERS Address: 2437 SOUTHCENTER MALL , TUKWILA, WA Phone: Property Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 Contact Person: Name: CONNIE GUFFEY Phone: 253-3323 X10 Address: 909 S 28TH STREET Contractor: Name: PLUMB SIGNS Phone: 253-473-3323 Address: 909 S 28TH ST DESCRIPTION OF WORK: 2 wall signs for Borders; shared tenant space wtih Seattle's Best Coffee. Permit # S08-041. SM Fees Collected: $250.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 5074 3159 0 0 Wall Sign Size (sq. feet): 121.7 119.3 0 0 Sign Lighting: Face Residential Land: N N Freestanding Sign #1 Street Frontage for Entire Lot: 0 Building Height (feet): 0 Sign Size (sq. feet): 0 Sign Height (feet and inches): 0 ' 0 " Setback (feet): 0 Number of Sign Faces: 0 Freestanding Sign #2 0 0 0 0' 0" 0 0 Planning Division Authorized Signature: tk",)\- rs\,) I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Date:J f S 6' THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM nnne S08-036 Printed: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-036 Address: 2437 SOUTHCENTER MALL TUB:W Status: PENDING Suite No: Applied Date: 04/25/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01581 Initials: MCB User ID: 1651 Payment Amount: $250.00 Payment Date: 05/13/2008 09:00 AM Balance: $0.00 Payee: pLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16924 250.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 250.00 Total: $250.00 2365 05/13 9711 TOTAL 50000 dor.: Raraint-(1R Pri ntari: 05-13-2fl0R City of Tukwila PER NO. D13 Departme•f Community Development ICIc[�cntcn 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206 431-3670 PERMANENT SIGN PERMIT APPLICATH'A Business Name Connie Guffey a57 Please print —63.3 Southcenter Mall Blvd Applicant/Contact plumb Signs Inc. Contractor Address of Sign 909 S. 28th S., Tacoma, 98409 Address, City, State, Zip Phone (253)473-3323 x10 Phone 909 S. 28th St., Tacoma, 98409 (253)473-3323 Address, City, State, Zip Phone CHECKLIST '❑ 3 sets of plans (dimensioned and scaled), including 'site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid`Washington State contractor's license $125 application fee per sign See back of form for examples MO' r� Y Is your sign a: ❑ Freestanding sign 15 or more feet in height sign with face 30 square feet or more in area .g --Well sigmvveighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) 0 Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding 8 Wall -y Did building, go through design review? 5 Yes ❑ No WALL SIGNS: #1 .!2 #3 #4 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) 1104 ' ••I_9 9 Sign size(square feet) AZO b /.2D Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of• LDR, MDR or HDR zones. ,J "i Does wall sign weigh more than 400 pounds?(Y/N) A) Al Sign illumination (internal/external/none) sNT Aitl1 i•✓v !Arr.' FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of si . n faces • If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila will be met. 4/22/08 f Date (Signa re o owner,�r • th Zoning: connie@plumbsigns.com ed agent) Email Address FOR OFFICE USE ONLY Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: ❑ Denied 0 Approved 0 Approved with conditions P:\Planning Forms\Applications\2007 Applications\PermSign-12-07.doc Revised on 12-07 • WALL AREA — SOUTH ELEVATION: 18' x 43' = 774 SQ. FT. X 6% = 46 SQ. FT. ALLOWED SIGN AREA — SOUTH ELEVATION: BORDERS W/UNDERSCORE: 2'10" X 11'9" = 34.6 SQ. FT. PROPOSED • 42" illuminated face lit NOTE: channel letters (3) 20 AMP/120 VOLT CIRCUITS REQUIRE 22" illuminated face lit channel letters Borders is respon ible for•mpliance with the Comprehe ove Sign Package for Southcent r as re uired by the City of Tukwila. Borders sign square footage cannot exceed 6° of the -xterior storefront elevations Borders is respQaslble for this com Iianc Signa • e must be on separate circuits and on 7 da—time clock set to hour P 9 P dal ie of-' ' _ - + _ = City --of Tukwila 43' x100' = 4,300 SQ. FT. X 6% = 258 SQ. FT. ALLOWED BORDERS W/UNDERSCORE: 5'4" X 22'10" = 120 SQ. FT. PROPOSED A/ SOUTH EL 3/32" =1'-0" SINCE Blade sign will (lowed as long as it is b 'nd glass T---nt'sspace ILLUMINATED SBC WINDOW SIGN SBC 328 BLADE SIGN NOTE: (1) 20 AMP/120 VOLT CIRCUIT REQUIRED z,4) 1V-113/4" 8" 1 SCALE: 1/4"=1'-0" SEE SPEC BRDR-CL-22-SC 11'- 93/8" 34.6 sq. ft ARTWORK EXCLUSIVE PROPERTY OF 1917 SMOKE FREE LABEL SEE BRDR_SMOKEFREE STORE HOURS SEE BRDR_HOURS ILLUMINATED RED BAR MOUNTED TO EXISTING CANOPY SEE R -339a.1 PLACE ADDRESS HERE SEE SPEC R -339A.001 I SCALE: 1/4"= 1'-0° APPROVALS Signatures Required Before Release to Production 22'-10 3/8" (6) WINDOW SAFETY VINYL LOCATIONS FOR INTERIOR SECOND FLOOR STORE HOURS SEE BRDR_HOURS SMOKE FREE LABEL SEE BRDR_SMOKEFREE Engineering MANDDVILLF SIGN 'I DATE Sales 676 GEORGE WASHINGTON HIGHWAY .. . LINCOLN, RI 02865-4255 ! . 10 I PHONE 401-334-9100 FAX 401-334-7799 11 qu . , WEB www.mandevillesign.com I DATE DATE DATE REVISIONS 120.0 sq. ft.� I NO I1 I2 BY DESCRIPTION DATE hd revised and redrawn to new cad files 10.07.07 10/11/07 hd added qty of amps per circuit and labels to top level entrance and double door per marked up print first floor 10/19/07 3 I4 5 6 AO' MAXIMUM 48" 34 1/4" Maud Slim &SWIM'liers+ew livalemel Waal Ibmsbult isienribolwarrsaiesioviesmatiiserm lime 11 ►1/fa4 4/10/08 w - 24" BC 328 BLADE SIGN SCALE: %" =1'-0" (SUPPLIED BY OTHERS) Must be behind glass within interior space BORDERS STORE NUMBER #126 LOCATION TUKWILA, WA. WORK ORDER NUMBER(S) ------ ---- KATHLEEN SWANSON PROJECT MANAGER NOTED II HD 'j 06/29/07 ((SCALE ARTIST Il DATE R - 339a 1 , DRAWING NAME /4`,i° 4 6 0 0 Tenants 16811-1 ,Birde_s , ll-.esponsiblef.forpliance with the ,GOMpfehopive Sigh Rackage.•for- Southcenter. as required bythe Cityof Tukwila. Borders s1gn square footage can q 9 exceed 6% of the exterior storefront elevations Borders is responsible for this compliance Signage must be on separate circuits and on 7 day time clock set to hou requirements of Westfield and tlif&gy of Tukwila NOTE: (3) 20 AMP/120 VOLT CIRCUITS REQUIRED 42" illuminated face lit channel letters • ±46'- 5" (V.I.F.) ILLUMINATED LOGO PENDANT SIGN S:C 308 •— EQ. WALL AREA —WEST ELEVATION: 27' x 117' = 3,159 SQ. FT. x 6% = 190 SQ. FT. ALLOWED SIGN AREA — WEST ELEVATION: BORDERS W/UNDERSCORE: 54" X 22'10" = 120 SQ. FT. PROPOSED SEATTLE BEST COFFEE: 3' X 4'3" = 12.75 SQ. FT. TOTAL PROPOSED: 132.75 SQ. ST. 0 WEST ELEVATION: 3/32"= 1'-0" Saw OrswUgQwbw as Mob/ Itimibordt lir}y '_ Is 1rrY�Yl�ww�t" M werysios-ri siesrAYQwswR rM h,►ai4.4/10/08 SINCE ARTWORK EXCLUSIVE PROPERTY OF ' LL' 1- WINDOW SAFETY VINYL NUMBER & LOCATIONS TO BE DET. SEE SHEET: BRDR WINDOW VINYL 1917 APPROVALS Signatures Required Before Release to Produdion Engineering DATE 22'-6" SCALE: 1/4". 1'-0" 22'-10 3/8" SEE SPEC. R -339A.001 REVISIONS 0 NO MANDVI,L• SIGN 'sales 676 GEORGE WASHINGTON HIGHWAY Production UNCOLN, RI 02865-4255 PHONE 401-334-9100 FAX 401-334-7799 Quality C tro WEB www.mandevillesian.com DATE DATE DATE BY DESCRIPTION hd added roof line height note hd revised and redrawn to new cad files 10.07.07 hd added amperage circuit size DATE 08/23/07 10/11/07 10/19/07 6 7 120.0 sq. ft. • 41 51 3/8" /'. 5��,4)/ 0 ILI IL MINATED LOGO W WALL SIGN SBC 308 (BY OTHERS) 0 SCALE: 1/2" =1-0" BORDERS CLIENT STORE NUMBER #126 SOUTH CENTER, TUKWILA, WA. R -339b LOCATION DRAWING NAME WORK ORDER NUMBERS) PROJECT MANAGER NOTED SCALE 16811-1 o }I CID ny 2 d 023 KATHLEEN SWANSON HD 06/29/07 '.' ARAST DATE 4— 1 DISCONNECT SWITCH TRIM -CAP CHANNEL LETTER FACE NEON TUBING ELECTRONIC TRANSFORMER NEON TUBE SUPPORT DISCONNECT SWITCH TRIM -CAP CHANNEL NEON TUBING LETTER FACE ELECTRONIC TRANSFORMER ,ALL BLOCKING PROVIDED BY LANDLORD, CROSS SECTION: CHANNEL LETTER wl SELF-CONTAINED TRANSFORMER ARTWORK EXCLUSIVE PROPERTY OF SINCE 1917 MAND, FVIL SIGN APPROVALS Signatures Required Before Release to Production Engineering DATE SCALE: 1/4"= V-0" 22'-10 3/8" INTERNALLY ILLUMINATED CHANNEL LETTERS "BORDER" SPECIFICATIONS • FACES: 7328 MATTE WHITE 3/16" ACRYLIC • RETURNS: BLACK, .040 ALUM., 8" DEEP • BACKS WHITE ALUMINUM .063" • TRIM -CAP: 2" BLACK • ILLUMINATION: 15MM 6500 WHITE • SELF-CONTAINED TRANSFORMERS 1 If weepholes are required no light leaks which will be • DISCONNECT SWITCHES q 9 _ • (2)'/4" DIA. WEEP HOLES FOR EACH LETTER (EXTERIOR ONLY) visible to public will be allowed. • U.L. AND MANUFACTURERS LABELS on TOP of LETTERS 120.0 sq. ft.ol ILLUMINATED UNDERSCORE CABINET : •FABRICATED BRAKE FORMED CABINET • .040 RED RETURNS 8" DEEP (TO MATCH CARDINAL RED VINYL) •.063" WHITE ALUMINUM BACK • 1" TRIM CAP RED, PAINTED TO MATCH CARDINAL RED VINYL (2" TRIM CAP ON LETTERS 42" AND TALLER) • .3/16" #7328 WHITE FACE wl FIRST SURFACE APPLIED VINYL #3630-53 CARDINAL RED • ILLUMINATION: 15MM 6500 WHITE (NOTE A MINIMUM OF 2" IS REQUIRED FROM EDGE OF RETURNS TO GRID WHEN TAG LINE REQUIRES MORE NEON) • WEEP HOLES (EXTERIOR ONLY) • U.L. AND MANUFACTURERS LABELS ON TOP OF UNDERSCORE BOX REVISIONS I NO 'I Sales 676 GEORGE WASHINGTON HIGHWAY Production LINCOLN, RI 02865-4255 PHONE 401-334-9100 FAX 401-334-7799 turn ,uu.....r.n.ln..illncinn rnm Quality Co DATE DATE BY DESCRIPTION 1a DATE 4 I.5 6 17 Lill "4st e&f 5 i I I Ilt OMANI Megrim in • raid Cr = Itemibmit yr isszeonnapiwin= 40 hla4/10/08 CLIENT BORDERS I WORK ORDER NUMBER(S) KATHLEEN SWANSON 16811-1 0) STORE NUMBER #126 LOCATION TUKWILA, WA. ! PROJECT MANAGER NOTED HD ' 06/29/07 II SCALE �t ARTIST !I, DATE R -339a.001 DRAWING NAME DCD-Intern2 Intern2 - R-339BV2.pdf NOTE• ROOF LINE VARIES FROM 36'-0" 67 COLUMN M10 TO 40'0" St COLUMN L 1 0 NOTE: (3)S AMR/1S V0LTC03CUR0 06000ED Q ikmmm Ere 11 `&aril IObs LEUMNED LOGO iErWN O'0,UC Y.3 i iii Ittl map p IIl I1hi d tiIIIIIIII�lllggll� I�Illglglll�lllllllllpll »NST ELEVATION 337= 1'4 Lou:v. .0 021.4255 WIDOW SAIE1,111. MASER &LOOUMS TO BERT. I SEES/EU: MN WIDOW N1M VP 41' L 5333 f'SOR.DaS I.SCALE: 1/4'= 1•.0 7710372 SE: SI''EL. /120/A001 REVSONB 1290sq 111 ILLUMINATED 1000 WAll. SIGN SEC 306 )BY OTHERS) SCALE 1/7 = 1%0' BORDFRS ' _U1 LP. -- - R-339bv2 I SIS-N5s