Loading...
HomeMy WebLinkAboutPermit S08-047 - WESTFIELD SOUTHCENTER MALLWESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL S08-044 THROUGH S08-51 FREESTANDING SIGNS SITE INSPECTION (PLANNING) File No. S08-044 Name of Tenant: Westfield Sign Address: 2800 Southcenter Mall Date Photo Taken: October 2, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-02-08 ay$ -o-1y File No. Name of Tenant: Sign Address: Date Photo Taken: x • • SITE INSPECTION (PLANNING) S08-045 Westfield 2800 Southcenter Mall October 2, 2008 Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Sign inspected and meets code. CT 10-02-08. Olive Garden Entrance JC Penny East Entrance • • SITE INSPECTION (PLANNING) File No. S08-046 Name of Tenant: Westfield Sign Address: 2800 Southcenter Mall Date Photo Taken: October 2, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-02-08. Firestone Entrance- Andover • • SITE INSPECTION (PLANNING) File No. S08-047 Name of Tenant: Westfield Sign Address: 2800 Southcenter Mall Date Photo Taken: October 2, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-02-08. Mervyn's East Entrance • • SITE INSPECTION (PLANNING) File No. S08-048 Name of Tenant: Westfield Sign Address: 2800 Southcenter Mall Date Photo Taken: October 2, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-02-08. Bahama Breeze North -Tukwila P flt :41.A Nordstrom West- Southcenter Pwy • • SITE INSPECTION (PLANNING) File No. S08-049 Name of Tenant: Westfield Sign Address: 2800 Southcenter Mall Date Photo Taken: October 24, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-24-08 i:° West mall entry- (Nordstrom File No. Name of Tenant: Sign Address: Date Photo Taken: • • SITE INSPECTION (PLANNING) S08-050 Westfield 2800 Southcenter Mall October 24, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-24-08 North mall entry "mmelwww. (Pm East mall entry biz File No. Name of Tenant: Sign Address: Date Photo Taken: • SITE INSPECTION (PLANNING) S08-051 Westfield 2800 Southcenter Mall October 24, 2008 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 10-24-08 Cascade Gara•e West Elevation- .arkin• ID 1� City PTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: S08-051 Issue Date: 05/30/2008 Permit Expires On: 11/26/2008 Business: Name: SOUTHCENTER/WESTFIELD MALL Phone: Address: 2800 SOUTHCENTER MALL , Property Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 Contact Person: Name: JOSH CHRISTENSEN Phone: 253 381-3026 Address: 909 SOUTH 28TH ST Contractor: Name: PLUMB SIGNS Phone: 253 473-3323 Address: 909 SOUTH 28TH ST DESCRIPTION OF WORK: 2/2 WALL SIGNS FOR WESTFIELD/SOUTHCENTER MALL - AA7 ON DIAGRAM - CB Fees Collected: $250.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 0 0 0 0 Wall Sign Size (sq. feet): 16.51 16.51 0 0 Sign Lighting: Face Residential Land: N N Freestanding Sign #1 Street Frontage for Entire Lot: 0 Building Height (feet): 0 Sign Size (sq. feet): 0 Sign Height (feet and inches): 0 ' 0 " Setback (feet): Number of Sign Faces: 0 0 Freestanding Sign #2 0 0 0 0' 0" 0 0 Planning Division Authorized Signature: - Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-051 Printed: 05-30-2008 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: S08-050 Issue Date: 05/30/2008 Permit Expires On: 11/26/2008 Business: Name: SOUTHCENTER/WESTFIELD MALL Phone: Address: 2800 SOUTHCENTER MALL , Property Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 Contact Person: Name: JOSH CHRISTENSEN Phone: 253 381-3026 Address: 909 SOUTH 28TH ST Contractor: Name: PLUMB SIGNS Phone: 253 473-3323 Address: 909 SOUTH 28TH ST DESCRIPTION OF WORK: 2-3/3 WALL SIGNS [AA3], 1/1 WALL SIGN [AA4], 1/1 WALL SIGN [AA6] FOR WESTFIELD/SOUTHCENTER MALL - CB Fees Collected: $500.00 Zoning: TUC Sign Type: PERMANENT SIGN: Wall Sign #1 Wall Sign #2 Wall Area (sq. feet): 0 0 Wall Sign Size (sq. feet): 65 65 Sign Lighting: Face Residential Land: N N Wall Sign #3 0 Wall Sign #4 0 53.8 N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 0 Building Height (feet): 0 0 Sign Size (sq. feet): 0 0 Sign Height (feet and inches): 0 ' 0 " 0 ' 0 " Setback (feet): 0 0 Number of Sign Faces: 0 0 Planning Division Authorized Signature' �.�__} . Date: I hereby certify that I have read and examine this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-050 Printed: 06-17-2008 Parcel No.: Address: Suite No: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT 6364200010 2800 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: S08-049 05/30/2008 11/26/2008 Business: Name: Address: Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SOUTHCENTER/WESTFIELD MALL Phone: 2800 SOUTHCENTER MALL , WESTFIELD PROPERTY TAX DEPT PO BOX 130940 JOSH CHRISTENSEN 909 SOUTH 28TH ST PLUMB SIGNS 909 SOUTH 28TH ST Phone: Phone: 253 381-3026 Phone: 253 473-3323 DESCRIPTION OF WORK: 1/3 WALL SIGNS FOR SOUTHCENTER/WESTFIELD MALL - AA3 ON DIAGRAM - CB Fees Collected: PERMANENT SIGN: Wall Area (sq. feet): Wall Sign Size (sq. feet): Sign Lighting: Face Residential Land: $500.00 Zoning: TUC Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Wall Sign #1 0 65 N Wall Sign #2 0 0 N Freestanding Sign #1 0 0 0 0' 0" 0 0 Wall Sign #3 0 0 Sign Type: Wall Sign #4 0 0 N N Freestanding Sign #2 0 0 0 0' 0" 0 0 Planning Division Authorized Signature: Date:_. I hereby certify that I have read and examined s permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-049 Printed: 06-17-2008 City Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: S08-048 Issue Date: 05/30/2008 Permit Expires On: 11/26/2008 Business: Name: SOUTHCENTER/WESTFEILD MALL Phone: Address: 2800 SOUTHCENTER MALL , Property Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 Contact Person: Name: JOSH CHRISTENSEN Phone: 253 381-3026 Address: 909 SOUTH 28TH ST Contractor: Name: PLUMB SIGNS Phone: 253 473-3323 Address: 909 SOUTH 28TH ST DESCRIPTION OF WORK: 4/4 FREESTANDING SIGNS FOR WESTFIELD/SOUTHCENTER MALL - AA2 ON DIAGRAM - SECOND SIGN IS AA1 ON DIAGRAM @ THE WEST EXIT ON SOUTHCENTER PY - CB Fees Collected: $250.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 0 0 0 0 Wall Sign Size (sq. feet): 0 0 0 0 Sign Lighting: Face Residential Land: Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 2000 2000 Building Height (feet): 30 30 Sign Size (sq. feet): 24.66 40.7 Sign Height (feet and inches): 8 ' 2 " 10 ' 2 " Setback (feet): 8.16 10.16 Number of Sign Faces: 1 1 Planning Division Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-048 Printed: ns-Rn-2nnR Parcel No.: Address: Suite No: City ilt Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT 6364200010 2800 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: S08-047 05/30/2008 11/26/2008 Business: Name: Address: Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SOUTHCENTER/WESTFEILD MALL Phone: 2800 SOUTHCENTER MALL , WESTFIELD PROPERTY TAX DEPT PO BOX 130940 JOSH CHRISTENSEN 909 SOUTH 28TH ST PLUMB SIGNS 909 SOUTH 28TH ST Phone: Phone: 253 381-3026 Phone: 253 473-3323 DESCRIPTION OF WORK: 2/4 FREESTANDING SIGN FOR WESTFIELD/SOUTHCENTER MALL - AA2 ON DIAGRAM - CB Fees Collected: PERMANENT SIGN: Wall Area (sq. feet): Wall Sign Size (sq. feet): Sign Lighting: Face Residential Land: $125.00 Zoning: TUC Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Wall Sign #1 0 0 Wall Sign #2 0 0 Freestanding Sign #1 2000 30 49.32 8' 2" 8.16 2 Wall Sign #3 0 0 Sign Type: Freestanding Sign #2 0 0 0 0' 0" 0 0 Wall Sign #4 0 0 Planning Division Authorized Signature. Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-047 Printed: 05-30-2008 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: S08-046 Issue Date: 05/30/2008 Permit Expires On: 11/26/2008 Business: Name: SOUTHCENTER/WESTFEILD MALL Phone: Address: Property Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 Contact Person: Name: JOSH CHRISTENSEN Phone: 253 381-3026 Address: 909 SOUTH 28Th ST Contractor: Name: PLUMB SIGNS Phone: 253 473-3323 Address: 909 SOUTH 28TH ST DESCRIPTION OF WORK: 1/4 FREESTANDING SIGNS AA2 - CB Fees Collected: $125.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 0 0 0 0 Wall Sign Size (sq. feet): 0 0 0 0 Sign Lighting: Face Residential Land: Freestanding Sign #1 Street Frontage for Entire Lot: 0 Building Height (feet): 0 Sign Size (sq. feet): 0 Sign Height (feet and inches): 0 ' 0 " Setback (feet): Number of Sign Faces: 0 0 Freestanding Sign #2 2000 30 24.66 8' 2" 8.16 1 Planning Division Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-046 Printed: n'_ln_7nna • City it Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: Suite No: PERMANENT SIGN PERMIT 2800 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: S08-045 05/30/2008 11/26/2008 Business: Name: Address: Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SOUTHCENTER/WESTFEILD MALL Phone: 2800 SOUTHCENTER MALL , WESTFIELD PROPERTY TAX DEPT PO BOX 130940 JOSH CHRISTENSEN 909 SOUTH 28TH ST PLUMB SIGNS 909 SOUTH 28TH ST Phone: Phone: 253 381-3026 Phone: 253 473-3323 DESCRIPTION OF WORK: 2/5 FREESTANDING SIGNS FOR WESTFIELD/SOUTHCENTER MALL - AA1 ON DIAGRAM - BOTH OF THESE SIGNS ARE DOUBLE SIDED, PARALLEL TO THE ROADWAY, ONE SIDE IS COUNTED ONLY -CB Fees Collected: PERMANENT SIGN: Wall Area (sq. feet): Wall Sign Size (sq. feet): Sign Lighting: Face Residential Land: $250.00 Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Wall Sign #1 0 0 Zoning: TUC Wall Sign #2 0 0 Freestanding Sign #1 2000 30 40.7 10' 2" 10.16 1 Wall Sign #3 0 0 Sign Type: Freestanding Sign #2 2000 30 40.7 10' 2" 10.16 1 Wall Sign #4 0 0 Planning Division Authorized Signature Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-045 Printed: 05-30-2008 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: S08-044 Issue Date: 05/30/2008 Permit Expires On: 11/26/2008 Business: Name: WESTFEILD/SOUTHCENTER MALL Phone: Address: 2800 SOUTHCENTER MALL , Property Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 Contact Person: Name: JOSH CHRISTENSEN Phone: 253 381-3026 Address: 909 SOUTH 28TH ST Contractor: Name: PLUMB SIGNS Phone: 253 473.3323 Address: 909 SOUTH 28TH ST DESCRIPTION OF WORK: 1/5 FREESTANDING SIGNS FOR WESTFIELD/SOUTHCENTER MALL - AA1 ON DIAGRAM - CB Fees Collected: $125.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 0 0 0 0 Wall Sign Size (sq. feet): 0 0 0 0 Sign Lighting: Face Residential Land: Freestanding Sign #1 Street Frontage for Entire Lot: 0 Building Height (feet): 0 Sign Size (sq. feet): 0 Sign Height (feet and inches): 0 ' 0 " Setback (feet): Number of Sign Faces: 0 0 Freestanding Sign #2 2000 30 81.4 10' 2" 10.16 2 Planning Division Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-044 Printed: n5-sn-2nn£i City &Tukwila • Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: ci. tukwila. wa. us Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Tenant: PLUMB SIGNS PERMIT CONDITIONS Steve Lancaster, Director Permit Number: S08-044 — Dc-/ Status: ISSUED Applied Date: 05/19/2008 Issue Date: 05/30/2008 1: 2: PERMITS ARE ISSUED WITH MINIMUM SETBACK VALUES APPLIED, APPLICANT MUST PROVIDE EXACT SETBACK MEASUREMENTS BEFORE FINALIZATION -CB **continued on next page** doc: Conditions S08-044 Printed: 05-30-2008 City a Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: ci.tukwila.wa.us Steve Lancaster, Director I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 5/30/0 doc: Conditions S08-044 Printed: 05-30-2008 Josh, I did a drive around the mall today and determined that neither of the two proposed AA5 signs will be visible from the public right-of-way so neither will require a permit to install [unless they are changed to illuminated in which case you would need an electrical permit]. Additionally, the AA6-11 sign that is facing east on the pedestrian bridge will fall under the same classification as not being visible from the public right-of-way so only an electrical permit will be required for that sign and we can subtract it from your total sign package's square footage. Unfortunately, AA6-16 will be visible from the public right-of-way so we will need to include that one in the package. Also, we have made a determination that all the signs under the designation of AB1 [3 signs], ADI. [11 signs] and AF1 [6 signs] will not be discernable from the public right-of-way so they will not need to be permitted for and you can begin work on them as soon as possible. Again, the subtraction of these signs will reduce your total amount of square footage in this package and make it much easier to stay within the 1200 sq ft parameters of this project. We appreciate the orderliness and completeness of this application Josh. I will work as hard as I can to get you the permits for these as quickly as possible as I understand this is probably a huge project for yourself and your company. I am now beginning the preliminary process of calculating your total sign package sq footage and will be entering these in to our permit processing software as early as Weds. I will keep you posted at all times. Thanks, DCD-Intern2 Intern2 - updated numbed From: To: Date: Subject: CC: Josh, DCD-Intern2 Intern2 josh@plumbsigns.com 5/21/2008 12:36 pm updated numbers Stacy MacGregor Ok, here are the new calculations: 330 sq ft from existing [S07-091] 529.1 sq ft [AA1 @ 40.7 each (that's with the bottom portion of the cabinet trim now removed) X 6 double faced + 1 single faced --> 40.7 X 2 = 81.4 X 6 = 488.4 + 40.7 = 529.1] _ i o , 7- 147.96 sq ft [AA2 @ 24.66 each (that's with the bottom portion of the cabinet trim now removed) X 3 double faced --> 24.66 X 2 = 49.32 X 3 = 147.96] Z 195 sq ft [AA3 @ 65 each (that's with only 3 counted because of the non -discernable nature of 3 of the 6 signs)] 126 sq ft [AA4 X 1 = 126 sq ft] 53.8 sq ft [AA6 X 1 = 53.8 sq ft] 33.02 sq ft [AA7 @ 16.51 each X 2] 1414.88 TOTAL SQ FT --> OVER 214.88 SQ FT Chris Beale Planning Intern DCD-Planning ex. 1141 email: DCD-Intern2 cbeale@ci.tukwila.wa.us 4 Z DCD-Intern2 Intern2 - Southcenter Mal• sues From: DCD-Intern2 Intern2 To: josh@plumbsigns.com Date: 05/19/2008 12:49 pm Subject: Southcenter Mall issues Josh, I have reviewed your application for the Southcenter Mall and made a few determinations that need some action. First, to get a few preliminary things out of the way, with all of the permits entered into our processing software it looks like the application fees for this package will be 2500$. You can mail me a check and I can return mail you your receipts as soon as I receive your payment. As for the package itself lets just recap a few things: all of the signage for this site must not exceed 1200 sq ft. There has already been 3 signs that Westfield applied and permitted for that equal out to be 330 sq ft [permit file # S07-091]. Your package as applied for does not include AA5 - both of these signs are not visible from the public right-of-way - AB1, AD1, AF1, and one of the two AA6 signs because it will not be visible from the right-of-way. While that significantly reduces your proposal the total will exceed the 1200 sq ft maximum. The way that our code is written we can use straight lines and right angles to draw a polygon around a wall sign to reduce its size. We cannot however do this for freestanding signs. This method resulted in a reduction in size of the 6 signs under AA3 from 80 sq ft to 65 sq ft, the 1 sign under AA4 from 154 to 126 sq ft, the 1 visible sign under AA6 from 64.8 to 53.8 sq ft and the 2 signs under AA7 down to 16.51 sq ft. We had to remeasure the signs under AA1 and AA2 to include the parts between the two cabinets. AA1 now measures out to 42.9 sq ft and AA2 measures out to 26.36 sq ft. So to recap: 330 sq ft from existing [S07-091] 300.3 sq ft [AA1 @ 42.9 each X 7] 79.08 sq ft [AA2 @ 26.36 each X 3] 390 sq ft [AA3 @ 65 each X 6] 126 sq ft [AA4 X 1 = 126 sq ft] 53.8 sq ft [AA6 X 1 = 53.8 sq ft] 33.02 sq ft [AA7 @ 16.51 each X 2] 1312.2 TOTAL SQ FT --> over 112.2 sq ft. . 1 7'f . to o ✓L -- What needs to happen is either a reduction in size for some of the proposed signs or taking some of the signs out of the package to meet the 1200 sq ft maximum requirement. Also, please remember that all freestanding signs must be set back from the property line an equal or greater distance to its height. So the signs under AA1 will need to at a minimum setback 10'-2", AA2 8'-2", etc. I look forward to hearing from you on what you want to do. I am out of the office for the rest of today and will be back in the office Weds from 7.30am-1.30pm. thanks, Chris Beale Planning Intern DCD-Planning ex. 1141 email: DCD-Intern2 cbeale@ci.tukwila.wa.us • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.waus RECEIPT Parcel No.: 6364200010 Permit Number: S08-051 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01875 Initials: CB User ID: 0400 Payment Amount: $250.00 Payment Date: 05/30/2008 01:10 PM Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16598 250.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 250.00 Total: $250.00 3036 05/30 9711 TOTAL 2125.00 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-050 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01874 Payment Amount: $500.00 Initials: CB Payment Date: 05/30/2008 01:08 PM User ID: 0400 Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16598 500.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 500.00 Total: $500.00 3036 05/30 9711 TOTAL 2125.00 Printori• nF_ln_7nna • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-049 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01873 Payment Amount: $500.00 Initials: CB Payment Date: OS/30/2008 01:05 PM User ID: 0400 Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16598 500.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 500.00 Total: $500.00 3036 05/30 9711 TOTAL 2125000 Dronroa• nc_zn_,,nna • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-048 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01872 Initials: CB User ID: 0400 Payment Amount: $250.00 Payment Date: 05/30/2008 01:00 PM Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16598 250.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 250.00 Total: $250.00 3036 05/30 9711 TOTAL 212500 o.; �e a• nR_1n_)nna • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-047 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01871 Payment Amount: $125.00 Initials: CB Payment Date: 05/30/2008 12:54 PM User ID: 0400 Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16958 125.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 125.00 Total: $125.00 3036 05/30 9711 TOTAL 2125=00 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-046 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01869 Payment Amount: $125.00 Initials: CB Payment Date: 05/30/2008 12:48 PM User ID: 0400 Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16958 125.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 125.00 Total: $125.00 3036 05/30 9711 TOTAL 2125.00 nc on nnna • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us RECEIPT Parcel No.: 6364200010 Permit Number: S08-045 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: Receipt No.: R08-01868 Initials: CB User ID: 0400 Payment Amount: $250.00 Payment Date: 05/30/2008 12:41 PM Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16958 250.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 250.00 Total: $250.00 3036 05/30 9711 TOTAL 2125.00 Prinrcrl• nc_zn_7nnR • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: S08-044 Address: 2800 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 05/19/2008 Applicant: PLUMB SIGNS Issue Date: 05/30/2008 Receipt No.: R08-01866 Payment Amount: $125.00 Initials: CB Payment Date: 05/30/2008 12:20 PM User ID: 0400 Balance: $0.00 Payee: JOSH FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16958 125.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 125.00 Total: $125.00 3036 05/30 9711 TOTAL 2125.00 f1C 7A .1/lf\fl • • Westfield Southcenter Mall sign count and conditions: AA1 freestanding signs: 4 Total of 4 AA1 freestanding signs will be permitted. AA1 sign at the south exit [located adjacent to the Cheesecake Factory] is double sided, 81.4 square feet, perpendicular to Strander Blvd. The setback for this sign must be equal or more than its height, 10'-2". 4 AAI sign at the south exit [located adjacent to the Olive Garden] will be counted as a single faced sign, 40.7 square feet. The sign will however be double sided with the second face not to be visible from the public right-of-way [parallel to Stander Blvd]. The setback for this sign must be equal or more than its height, 10'-2". -� AA1 sign at the east exit [located north of Firestone and west of Acura] will be counted as a single faced sign, 40.7 square feet. The sign will however be double sided with the second face not to be visible from the public right-of-way [parallel to Andover Park West]. The setback for this sign must be equal or more than its height, 10'-2". AA1 sign at the west exit [located at the intersection of Southcenter Pkwy and the I-5 exit ramp] is single sided, 40.7 square feet. The setback for this sign must be equal or more than its height, 10'-2". AA2 freestanding signs: 4 Total of 3 AA2 freestanding signs will be permitted: 4 AA2 sign at the access point between Firestone and the US Post Office is single sided, 24.66 square feet. The setback for this sign must be equal or more than its height, 8'-2". 4 AA2 sign at the access point just south of the Bank of America [north eastern access point on Andover Park West] is a double sided sign, 49.32 square feet. The setback for this sign must be equal or more than its height, 8'-2". 4 AA2 sign at the north western access point adjacent to Bahama Breeze is single sided, 24.66 square feet. The setback for this sign must be equal or more than its height, 8'-2. AA3 wall signs: 4 Total of 3 AA3 wall signs will be permitted: Each AA3 sign is 65 square feet, a total of 195 square feet will be counted. AA4 wall sign: 4 One AA4 wall sign will be permitted: -4 This one wall sign is 126 square feet in size. AA6 wall sign: 4 One AA6 wall sign will be permitted: • • 4 This one wall sign is 53.8 square feet in size. AA7 wall sign: 4 Two AA7 wall signs will be permitted: 4 Each AA7 wall sign is 16.51 square feet, a total of 33 square feet will be counted. Summary: S07-091 permitted for 330 square feet [existing signage now] AA1 [x4] total sign square footage: 203.5 AA2 [x3] total sign square footage: 98.64 AA3 [x3] total sign square footage: 195 AA4 [xl] total sign square footage: 219.5 AA6 [xl] total sign square footage: 53.8 AA7 [x2] total sign square footage: 33 1133.44 square feet Potential addition: Another AA1 sign will potentially be permitted for in the future at the northern access point off of Tukwila Pkwy [located adjacent to the current Bank of America]. This sign would potentially be double sided, counting as 81.4 square feet. The total square footage allowed for this site will be limited to 1200 square feet. With this addition the total sign square footage count would be bumped to 1186.72. ON HOLD as of 07.08.2008 -4 AA1 sign at the corner of Southcenter Pkwy and Strander Blvd is single sided, 40.7 square feet. The setback for this sign must be equal or more than its height, 10'-2". 4 AA2 sign at the intersection of Tukwila Pkwy and the overpass of I-405 will be counted as a single faced sign, 24.66 square feet. The sign will however be double sided with the second face not to be visible from the public right-of-way [parallel to Tukwila Pkwy]. The setback for this sign must be equal or more than its height, 8'-2". ADDITIONAL NOTES: 4 The total of these two signs is 65.36 square feet which can be permitted in the future. The total square footage with these two reserved signs would equal 1198.8 square feet, leaving only 1.2 square feet under the 1200 square foot allowed budget. Additionally, permit number S08-049 has only one sign issued under its designation but the applicant paid for 4 signs, leaving them with the option of adding these two signs [listed above] without needing to pay for them plus another sign in the future. Westfield Southcenter WESTFIELD SIGNAGE BUDGET (LIMIT 1200 SQ.FT.) Type Type Type rn q,? (kt (,0>✓ 0 2 — CIU (c0 T Location Orientation Sides Size to Street Sq.Ft. Permit Number Notes? ll ntalledf/[Aanlied(fo'r1P�ermit1 r1 Garage 2 Garage 3 Garage 4 Monument 5 Monument 6 Monument 7 Monument 8 Monument 9 Monument 10 Monument rit Entry 12 Entry 13 Entry 14 Main Entry 15 Bridge 16 Parking ID 17 Parking ID Wall Wall Wall Freestanding Freestanding Freestanding Freestanding Freestanding Freestanding Freestanding Wall Wall Wall Wali Wall Wall Wall SUB -TOTAL Not Discce ably 18 Entry 19 Entry 20 Entry (�t3� Cascade Garage - South Olympic Garage - West Olympic Garage - South AA1 Cheesecake Entrance - Strander AA1 Olive Garden Entrance - Strander AA1 JCP East Entrance - Andover AA2 Firestone Entrance - Andover AA2 Mervyn's East - Andover AA2 Bahama Breeze North - Tukwila Pwy AA1 Nordstrom West - Southcenter Pwy AA3 West Mall Entry (Nordstrom) AA3 _North Mali Entry (Johnny Rockets) AA3 East Mall Entry (JCP) AA4 Main Entry Sign (7'h) AA6 JCP Bridge AA7 Cascade Garage - West AA7 Olympic Garage - East (Does not count towards the 1200 SF limit) Wall AA3 South-West Mall Entry (Sears) Wall AA3 South -East Mall Entry (Racha) Wall AA3 $ov'n; •gAsT (14 Intalled 21 Monument 22 Monument Applied f P Freestanding Freestanding SUB -TOTAL TOTAL AA1 Bank of America Adjacent AA2 North - Freeway overpass "T" LIMIT Surplus Area / (Over) Future 25 Monument Freestanding AA1 SW - Strander & Southcenter Pwy Wall Mounted Wall Mounted Wall Mounted Perpendicular Parallel Parallel Parallel Perpendicular Parallel Parallel Wall Mounted Wall Mounted Wall Mounted Wall Mounted Wall Mounted Wall Mounted Wall Mounted 1 side 110.00 S07-091 W1 1 side 110.00 S07-091 W2 1 side 110.00 S07-091 W3 2 sided 81.40 S08-044 FS2 1 sided 40.70 S08-045 FS1 1 sided 40.70 S08-045 FS2 1 sided 24.66 S08-046 FS2 2 sided 49.32 S08-047 FS1 1 sided 24.66 S08-048 FS1 1 sided 40.70 S08-048 FS2 1 side 65.00 S08-049 W1 1 side 65.00 S08 -0'o W2. 1 side 65.00 S08 -06D W3 1 side 210 S08-050 W3 1 side 5b.ov S08-050 W4 1 side 16.50 S08-051 W1 1 side 16.50 S08-051 W2 A Il33.gc{ Wall Mounted 1 side Wall Mounted 1 side Wall Mounted 1 side Parallel Parallel 1 sided 1 sided B V\S''c \yvAS 1`2,4 41) 65.00 S08-049 W4 ` 65.00 S08-050 W1 65.00 S08-050 W2 Where is this? 40.70j 24.6 C 1,198.80 =A+B D 1,200.00 45 degrees 1 sided 1.20 =D -C 40.70 (Per City of Tukwila) WF SCR Ext Sign Bgt 2008 07 09.xis Sheetl 7/9/2008 11:56 AM 1 wT? ` 1 - • @SEE LRMIC 'DctF /"1 -r ..�..,1 •�•v, ._.< <.--I•`e-Ir• / J&t .41•4-, . Ye,M I r : 6 .- cq o 5: d'/. 4,6, 0 �crg��r : 261 SEE SEE PROPERTY UNE c' 5 cel g / n 4-2 'ARK WA SIGNALIZED INTERSECTION 0 r+L ' SEE SIGNAUZ INTERSE SEE SEE @, SEE @, SEE Perztit,r# : 5 ce-cK + 17h q. 32_ 0 I �jEf(j,4Gr ' 3-t 2 SETBACK LINE PROPERTY LINE NORDSTROM 3 LEVELS U �I rL kPQ-r 24R#tir; r =iatiyC kh II SIGNAUZED6 I ----�__ INTERSECTION @SEE All \ CIO11111 o o n (\1s11fiZIt 414?:'YOU r -.•JI eb '' SEE @, e C.FNFRAI NOW: ® FOR DETAILED INFORMATION OF WESTFIELD SITE ID e SIGN — REFER TO SIGNAGE PACKAGE BY SQUARE PEG D1 DESGIN 55: 7- 6erg.4v_: Z. 4 PLANTERS PER LANDSCAPE DRAWING L FUTURE PAD SEE NOTE S 38.7 nem ..:._!!7! TT: SIGNZED NTERAUSECTION 1+ STRANGER BOULEVARD EXISTING TREES SEE SEE NORTH ��tlfil SoutFcenter r ".7 AESTF1ELD DESIGN & CONSTRUCTION 11101 &whirs Boulinord. 11th Floor Larmitrm. OeOMnio 1746 Telae 310 8 4486 FmiraIS N 3310 47 476 4486 . 691100 v mw., x 110001 Mt Mt M®: � Wi 103 mR�a m� M 0001.71 max me �....ose.vM.�.. Registration No. Consultants Approvals/Phase: Site Signage - Landscape Package 4/19/2007 Date a - A A A A A A A °a 0 0 A S met „be PROPOSED FREESTANDING SIGNAGE SITE PLAN Job No. 110 Date 41.GI Scale 1+714. AL 1.1-0 SSEE 5/r Kcive(A Uig r i '1 I'D (JO Blue s ax'e actua-1 PARk WA ZED Iii:RSECTION SIGIXIZFD DItFRSCCfO*: Westilek! Southcenter B(C) OREE7 SEE SEE NESTRELO DESIGN & ( 11601 Mttd 11th Floor In tr;;, Cmb fam Telephone 000 -1 710 478 443E Fon nIM 710 478 4468 *lop 00.12:04 v�p�, 9ONm0.0 lRal ONF.'1 i;grt r.RiEi Rb5:111tl.O..( .wi.rtC( SEE it i I i !` I I II 1I II P T 0 TJ 0/1= SEE Registration No. ._t. IKKEILE SEE MATTHEW BOREEN Consultants tc- AKA menryars 2 LEWES PROPERTY LIKE SETBACK LINE PP.DPERTY LINE NORDSTROM t.I:vas • 3SEE SIGN 1V1E 5,/ SSEE .'` Z6 3 • Approvals/Phase: Site Signage - Landscape Package 4/19/2007 , -i`3 6' SEE (, (FNFRAL NOV ®FOR DE IAILED INF0RMA TION OF WESTTIELD 5I TE ID ®SICN - REFER TO SIGNAGE PACKAGE 8Y SQUARE PEG DE5G1N SICNA!JZE . -�� It1TERSECTI ISEE \ L 'Anus SEE 14• PLANTERS PER LANDSCAPE DRAWING SEE ♦-4 FU TURF PAD SEE WE No. Revision Date p_ A 0 A A A Q Sheet Me PROPOSED FREESTANDING SIGNAGE SITE PLAN WF -ASK -018 1 11JlllIIII1 STRANDER BOULEVARD A r �r II it EXISTING TREES Q N OR Tri Job No. 112) Data 41141 Scale 1.aa • @SEE �7 YeIM t r.: ,5co3- ot/8 PROPERTY LINE SEE@Z /N ye; �crq i- : 2°►, SIGNALIZED INTERSECTION (✓}G .2 M rG&Q '17 Ot'/ tC J1 t^L0 Southcenter SEE PROPERTY UNE y v .7 D1 SEE(, SEE@, D1 SEE@, .1.111.1{ MN�mcm. m� . e uwrttrt Onr:..a I% 9610. , vbnFM PFglS90 H.V. Pot. ARO„CC1 Registration No. + 06 L//,32._ '" SETBACK LINE PROPERTY LINE Consultants .7c2M i/- - : eX8 NORDSTROM 3 LEVELS Approvals/Phase: Site Signage - Landscape Package 4/19/2007 SEE Key Plan: % c// : 2(0' SEE 1 J L 9641:( r reO - Y0 l +' jC-'T34 : 249' 1 SEE@, • QFNFRAL NOTF• ® FOR DETAILED INFORMATION OF WESTFIELD SITE ID e SIGN — REFER TO SIGNAGE PACKAGE BY SQUARE PEG D1 DESGIN INTERSECTION SEE FIPESTONE CPENNEY T.BA LEASE PARCEL 1 02 ACRES 38 CARS PLANTERS PER LANDSCAPE DRAWING 9 irx � r 7�rZM/r4- —oct _ go, 7m V 00A FUTURE PAD SEE NOTE No. Revision Date - A A A A A A A A 0 Sheat This PROPOSED FREESTANDING SIGNAGE SITE PLAN SE Job No. m Date 41901 Scale 1'!PP ass's m �4S7PS STRANDER BOULEVARD EXISTING TREES til — . _ L - / nw n .gt[cI T'1 7 .,.., 1 . Ar— r11 / L—.s — __ . �.n/ Westfield Southcenter WESTFIELD SIGNAGE BUDGET (LIMIT 1200 SQ.FT.) Type Type Type Location Orientation Sides Size to Street Sq.Ft. Permit Notes? Number Intalled / Applied for Permit 1 Garage Wall 2 Garage Wall 3 Garage Wall 4 Monument Freestanding AA1 5 Monument Freestanding AA1 6 Monument Freestanding AA1 7 Monument Freestanding AA2 8 Monument Freestanding AA2 9 Monument Freestanding AA2 10 Monument Freestanding AA1 11 Entry Wall AA3 12 Entry Wall AA3 13 Entry Wall AA3 14 Main Entry Wall AA4 15 Bridge Wall AA6 16 Parking ID Wall AA7 17 Parking ID Wall AA7 SUB -TOTAL Not Discernable 18 Entry 19 Entry 20 Entry Not Yet Intalled / 21 Monument 22 Monument 23 Entry 24 Main Entry • Cascade Garage - South Olympic Garage - West Olympic Garage - South Cheesecake Entrance - Strander Olive Garden Entrance - Strander JCP East Entrance - Andover Firestone Entrance - Andover Mervyn's East - Andover Bahama Breeze North - Tukwila Pwy Nordstrom West - Southcenter Pwy West Mall Entry (Nordstrom) North Mall Entry (Johnny Rockets) East Mall Entry (JCP) Main Entry Sign (7'h) JCP Bridge Cascade Garage - West Olympic Garage - East (Does not count towards the 1200 SF limit) Wall AA3 South-West Mall Entry (Sears) Wall AA3 South -East Mall Entry (Racha) Wall AA3 ? Applied for Permit Freestanding AA1 Freestanding AA2 Wall AA4 Wall AA4 SUB -TOTAL TOTAL LIMIT Surplus Area / (Over) Future 25 Monument Freestanding Bank of America Adjacent North - Freeway overpass "T" Main Entry Sign (8'-6"h) REMOVE Main Entry Sign (7'h) Wall Mounted 1 side 110.00 Wall Mounted 1 side 110.00 Wall Mounted 1 side 110.00 Perpendicular 2 sided 81.40 Parallel 1 sided 40.70 Parallel 1 sided 40.70 Parallel 1 sided 24.66 Perpendicular 2 sided 49.32 Parallel 1 sided 24.66 Parallel 1 sided 40.70 Wall Mounted 1 side 65.00 Wall Mounted 1 side 65.00 Wall Mounted 1 side 65.00 Wall Mounted 1 side 126.00 Wall Mounted 1 side 53.80 Wall Mounted 1 side 16.50 Wall Mounted 1 side 16.50 A 1,039.94 Wall Mounted 1 side Wall Mounted 1 side Wall Mounted 1 side Parallel Parallel Wall Mounted Wall Mounted 1 sided 1 sided 1 side 1 side B S07-091 S07-091 S07-091 S08-044 S08-045 S08-045 S08-046 S08-047 S08-048 S08-048 W1 W2 W3 FS2 FS1 FS2 FS2 FS1 FS1 FS2 S08-049 W1 S08 -04$? -0-2!0619 O9 S08-045'' 33' S08-050 W3 S08-050 W4 S08-051 W1 S08-051 W2 65.00 S08-049 W4 65.00 S08-050 W1 65.00 S08-050 W2 Where is this? 40.70 24.66 219.50 (126.00) 158.86 C 1,198.80 =A+B D 1,200.00 AA1 SW - Strander & Southcenter Pwy 45 degrees 1 sided 1.20 =D -C 40.70 (Per City of Tukwila) WF SCR Ext Sign Bgt 2008 07 09.xis Sheetl 7/9/2008 11:56 AM 1 • • REQUEST FOR ADDITIONAL INFORMATION July 11, 2008 Mr. Josh Christensen Plumb Signs, Inc 909 S. 28th Street Tacoma, WA 98409 RE: Westfield Mall S08-049 Dear Mr. Christensen, In order to process you application for a permanent sign permit, the City requires additional information. Two of the signs you included in your permit — AA1 Adjacent to Bank of America and AA2 North — Freeway overpass "T" — have been removed from your permit application due to the potential future use of the area being undetermined. A refund has not been issued to you at this time. If you would like to revise this permit to reflect the installation of these two permits at any time you may do so without needing to pay the application fee again. The additional information needed at the time of revision would be the placement of the sign, its orientation to the street and its setback distance from the current property line. If you have any questions with this matter you may call me at 206-433-7141 Sincerely, Chris Beale Planner City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 206 431-3670 PERMIT NO. 5OR Oc-r 06-0 DATE: 0.6 19. O? PERMANENT SIGN PERMIT APPLICATION Westfield Business Name Connie/Josh Applicant/Contact Plumb Signs Inc. Contractor Please print 2800 Southcenter Parkway Address. of Sign 909 S. 28th St., Tacoma, Phone RECEIVED 98409 (253)473-33 Y 1 9 2008) Address, City, State, Zip 909 S. 28th St., Phone Tacoma, 98409 (253)473-332toMMUNITY NT Address, City, State, Zip Phone CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions B Building elevations (for wall signs) Supporting structure and method of illumination (g" One copy of valid Washington State contractor's license $125 application fee per sign See back of form for examples Is your sign a: E'f Freestanding sign 15 or more feet in height Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? 2 Yes 0 No Wall 1/ WALL SIGNS: A A3 X 6 .S/b,vs Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) Sign size(square feet) (PD ,Q' x 4....1/4,A.4.3 Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. A.1 p Does wall sign weigh more than 400 pounds?(Y/N) �/p Sign illumination (intemal/extemal/none) „x,17•. FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -Inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of si • n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing Inspections must take place before concrete Is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for a!! signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6639. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila . ' be met. 5/12/08 Date Ignature of owner or a Zoning: onzed FOR OFFICE USE ONLY connie@plumbsigns.com josh@plumbsigns.com Email Address Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions P:\Planning Forms\Applications\2007 Applications\PermSign-12-07.doc Revised on 12-07 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206 431-3670 PERMIT NO. '3 c3 - o'57 06-. 7 Q. os PERMANENT SIGN PERMIT APPLICATION Westfield Business Name Connie/Josh Applicant/Contact Plumb Signs Inc. Contractor Please print 2800 Southcenter Parkway Address of Sign 909 S. 28th St., Tacoma, Address, City, State, Zip 909 S. 28th St., MAY 9 2008) Phone 98409 ( 253 )473-3ii 010111KuNITI80 Phone Tacoma, 98409 (253)473-3323 Address, City, State, Zip Phone CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $125 application fee per sign See back of form for examples Is your sign a: al Freestanding sign 15 or more feet in height Pole sign with face 30 square feet or more in area O Wall sign weighing 400 pounds or more If any of the above are true, the appllcat/on must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? r,sit Yes 0 No Wall •5% WALL SIGNS: .441 x Gie i3i6,,✓s Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) Sign size(square feet) / 7 / X ,.2 ,—?j6-��t/S Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. 4. , p Does wall sign weigh more than 400 pounds?(Y/N) .cJ O Sign illumination (intemal/extemal/none) At,sp,vS FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated _ , Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of sl• n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila be met. C o n n i e @ p l u m b S 1 g n S. C O m 5/12/08 josh@plumbsigns.com Date ignature of owner or au Zoning: FOR OFFICE USE ONLY Email Address Planning review by: O Denied ❑ Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions P:\Planning Forms\Applications\2007 Applications\PermSign-12-07.doc Revised on 12-07 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206 431-3670 PERMIT NO. 05-0 PERMANENT SIGN PERMIT APPLICATION Westfield Business Name Connie/Josh Applicant/Contact Plumb Signs Inc. Contractor Please print 2800 Southcenter Parkway Address of Sign 909 S. 28th Address, City, State, Zip 909 S. 28th Address, City, State, Zip Phone RECEIVED St., Tacoma, 98409 (253) 473-3,32a i 9 2008 Phone St . , Tacoma, 98409 ( 253) 473-3 I►MUTY �E�pPNtMENT Phone CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions ID Building elevations (for wall signs) Supporting structure and method of illumination l3 One copy of valid Washington State contractor's license $125 application fee per sign See back of form for examples Is your sign a: [a Freestanding sign 15 or more feet in height VI Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? [W' Yes ❑ No Wall 1' WALL SIGNS:841 G X feil, / ..1/ 6.,-%5 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) Sign size(square feet) low • 1 X f 10 .,,-1' 6 --•✓S Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. dtJ O Does wall sign weigh more than 400 pounds?(Y/N) ,v0 Sign illumination (internal/external/none) "ti r FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding signis allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. • Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of si • n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila be met. connie@plumbsigns.com 5/12/08 josh@plumbsigns.com Date Zoning: A /fes gnature of owner or au, onzed / FOR OFFICE USE ONLY Planning review by: ❑ Denied Email Address ❑ Issued ❑ Issued with conditions Structural review required? 0 Yes ❑ No Structural review by: O Denied 0 Approved ❑ Approved with conditions P:\Planning Forms\Applications\2007 Applications\PermSign-12-07.doc Revised on 12-07 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206 431-3670 PERMIT NO. PERMANENT SIGN PERMIT APPLICATION Westfield Business Name Connie/Josh Applicant/Contact Please print 2800 Southcenter Parkway Address of Sign 909 S. 28th St., Tacoma, RECEIVEC Phone 98409 (253) 473-332bAY 1 9 200E Address, City, State, Zip Plumb Signs Inc. 909 S. 28th St., Contractor Phone COMMUNITY Tacoma, 98409 ( 2 5 3 ) 47 3 —33 2 3DEVELOPMENT Address, City, State, Zip Phone CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs • Sign elevations with area calculations and dimensions lig Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $125 application fee per sign See back of form for examples 113 521) Is your sign a: ['S Freestanding sign 15 or more feet in height R3 Pole sign with face 30 square feet or more in area O Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? ® Yes 0 No Wall '/ WALL SIGNS: 4A' y x / ../'6-.✓ Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) Sign size(square feet) /„S"yOf Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. WD Does wall sign weigh more than 400 pounds?(Y/N) yp Sign illumination (intemal/extemal/none) /AI 7- FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of si • n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6631i SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila . be met. 5/12/08 Date connie@plumbsigns.com josh@plumbsigns.com ignature of owner or au '. onzed / Email Address Zoning: FOR OFFICE USE ONLY Planning review by: O Denied 0 Issued O Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied P:\Planning Forms\Applications\2007 Applications \ PermSign-12-07.doc 0 Approved O Approved with conditions Revised on 12-07 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206.431-3670 PERMIT NO. jab -QC( 'f61 oz -e, PERMANENT SIGN PERMIT APPLICATION Westfield Business Name Connie/Josh Applicant/Contact Plumb Signs Inc. Contractor Please print 2800 Southcenter Parkway Address of Sign 909 S. 28th St., Tacoma, Address, City, State, Zip 909 S. 28th St., Address, City, State, Zip Phone 11 98409 (253)473-3323 D Phone MAY 1 9 20081 Tacoma, 98409 (253)473-3323 COMMUNITY • Phone DEVELOPMENT CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $125 application fee per sign See back of form for examples Is your sign a: Freestanding sign 15 or more feet in height Eid Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the appllcatlon must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding �'• Did building go through design review? ® Yes ❑ No Wall WALL SIGNS: #4 Wall area (length x height) of the tenant space where the s!gn will be mounted? (square feet) Sign slze(square feet) Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. Ty/w Does wall sign weigh more than 400 pounds?(Y/N) Sign illumination (internal/external/none) FREESTANDING SIGNS: 4 ,4. o2, e«,-.06 O Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated je i Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area 40.24/ X ...//6-4445 Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. .3 / J" Distance from closest edge of sign to property lines (feet). Generally, signs must be set, back from all property lines a distance equal to their height. / Number of sl .n faces INSPECTIONS o A &.L ,.4' ` • If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-663p. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUAN▪ CE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila , be met. 5/12/08 Date connie@plumbsigns.com josh@plumbsigns.com gna ure of owner or au o zed / Email Address Zoning: FOR OFFICE USE ONLY Planning review by: ❑ Denied ❑ Issued ❑ Issued with conditions Structural review required? ❑ Yes ❑ No Structural review by: ❑ Denied P:\Planning Forms\Applications\2007 Applications \ PermSign-12-07.doc O Approved ❑ Approved with conditions Revised on 12-07 WV yr 1 aan rinca PERMIT NO. J cin Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 206 431-3670 DATE: c7 l 9.0g PERMANENT SIGN PERMIT APPLICATION Westfield Business Name Connie/Josh Applicant/Contact Plumb Signs Inc. Contractor Please print 2800 Southcenter Parkway MAY 1 9 2008 Address of Sign Phone COMMuNI TY 909 S. 28th St . , Tacoma, 98409 (253) 473-9'DPT Address, City, State, Zip Phone 909 S. 28th St., Tacoma, 98409 (253)473-3323 Address, City, State, Zip Phone CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs • Sign elevations with area calculations and dimensions • Building elevations (for wall signs) Supporting structure and method of illumination E3 One copy of valid Washington State contractor's license • $125 application fee per sign See back of form for examples 7:1 Is your sign a: E:}3 Freestanding sign 15 or more feet in height Ea Pole sign with face 30 square feet or more in area O Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: O $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding %j" Did building go through design review? ® Yes 0 No Wall V WALL SIGNS: Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) Sign size(square feet) Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. /1/2/3#4 Does wall sign weigh more than 400 pounds?(Y/N) Sign illumination (internal/extemal/none) FREESTANDING SIGNS: 4.,4 j Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. d d 4 4 Height of building (feet). Generally, signs may not be higher than the building with which they are associated ..54D , Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area 4162' 7- '5'21 ;_ ,;,',,,'-71:,.-,;;; 751-&---v Sign height (feet -Inches). Structural review is required for signs 15 feet or more in height. �D ¶.,t /I *5/6-.4,4 Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. - /e '2." Number of sign faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila . • be met. 5/12/08 / / Connie@plumbsigns.com josh@plumbsigns.com Date Email Address Zoning: FOR OFFICE USE ONLY Planning review by: O Denied O Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied P:\Planning Forms\Applications\2007 Applications \ PermSign-12-07.doc O Approved 0 Approved with conditions Revised on 12-07 'K sTrR rn]anss[ftng nal CONSULTING ENGINEERS/CIVIL AND STRUCTURAL STRUCTURAL DESIGN CALCULATIONS OF WESTFIELD SIGN FOUNDATION 633 Southcenter Boulevard Tukwila, WA 98188 FOR PLUMB SIGNS 909 South 28th Street Tacoma, WA 98409 REI Job No. 08049 April 2008 • 1519 West Valley Highway North/Suite 101 Post Office Box 836/Auburn, WA 98071 253-833-7776 Fax 253-939-2168 16-2" 10'-8" PROVIDE SUPPORT FOR FRONT AND REAR ACRYLIC PANELS J � Z CL � Q O � d NJ N w U D Q > c O Q w Q IFY #4's *11 SIGN, BY OTHERS 3" CLR 2'-7" MIN •4-741-1--I+ :,,;1--1.- --r= 4-t=-_ - -+ 4-- -4 +2--+_#- ,...e,.. + 14 4-1— 4-1— =41- } - 'I I 14 • ' 4 4 I• " ♦ 1- ! - . '11 . 6 a -• 1 - 1 : ♦ t _ ° - Is • : s _ "1 I. " I f. - 1 -. " ♦ .-♦ 1-1 a4 . P • 1 .1 • 1 I: - • I a .1 _ r -1. L 4 j- � 1- -� • - . _• - - _ 1 = � 1 f e • A 4... - .. _ - t - I . .r" ii • _s7•1.1 1+-4-4 _ .1 GL• • I oI 4 • 1 r i - i• ♦- _ '1 -- 1_ - 41' - P 1 •a. 1. e - 1 1 • 1 .'1 -1 » 4 - .1 - Q _ i . 1 :1 4 1. I. 1- e. 1"'11 I ♦ 1•'1 •1 - 1,11 •s • _ _ d 4. : 1' 4-11 1.1 1.1 ••• a-- .1 1P - _1-_ ' r. 1 1 -• r P J • 4• • -1 Id .11 ' • 3° -'t-P I 4 "e 1 •11! 1- 4 Psi "t- • -I - 1 _ I - -I • 11. 4. •.Ie ••I I • r a1 '• L 1' 1 1 s•1 - • _ 1 I° 41 ♦ 1• I 41 - 1 : ' - 1 - • •1.1'' + CLR n U U • .p _ : r ti • u Li .'- L.I. .: !r�." 1- 4 -L 1 • !. u 4 LJ - ' LJ " L.1 . u !4J U THIS SIGN FOUNDATION ANALYSIS IS BASED ON SOIL BEARING PRESSURES TAKEN FROM THE RECOMMENDATIONS MADE IN GEOTECHNICAL REPORT #21-1-20189-004 PREPARED BY SHANNON & WILSON ON 10/27/05. IF SITE CONDITIONS DIFFER FROM THESE ASSUMPTIONS, THE ENGINEER MUST BE NOTIFIED SO THAT THE ANALYSIS MAY BE UPDATED TO MEET ACTUAL SITE CONDITIONS. 11' 6" F APPLY EPDXY PAINT TO ALUMINUM TUBES TO PREVENT CORROSIVE INTERACTION BETWEEN ALUMINUM AND CONCRETE. CAP BOTTOM OF TUBE AND APPLY PAINT OR PAINT TUBE INSIDE AND OUTSIDE. (TYP) #4's 2'-0' n l .� e - - _ . 4 d ♦=•�• - e•: - •a_ .. n I, • - _-0 - ` a • a 0 ° --' -- a • ♦ ' Q°•-• ♦°=o ♦•o-_! ca- a _ 4 ♦• (8) 2.50 OD x 0.500 WALL 6061-T6 ALUMINUM TUBES (9) 2.00 ,00 x 0.438 WALL 6061-T6 ALUMINUM TUBES RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Aubum, WA 98001 PROJECT NAME: WESTFIELD SIGN FOUNDATION, SIGN AA1 633 Southcenter Boulevard, Tukwila, WA 98188 SCOPE OF WORK: Determine the column and footing requirements for the sign subject to static wind Loading per the 2006 International Building Code and ASCE 7-05. All sign material and connections to column by others. DESIGN CRITERIA: Basic Wind Speed: V = 85 MPH ASCE 7-05 FIGURE 6-1 Exposure Category C ASCE 7-05 Section 6.5.6.3 Wind Importance Factor: I,, = 0.87 ASCE 7-05 TABLE 6-1 Total Height of Sign: 10.17 FT Nominal Height of Atmospheric Boundary layer. z9 = 900 FT ASCE 7-05 TABLE 6-2 Power Law Exponent: a = 9.5 ASCE 7-05 TABLE 6-2 Exposure Constant zh,;,, = 15 FT ASCE 7-05 TABLE 6-2 Turbulence Factor. c = 02 ASCE 7-05 TABLE 6-2 Integral Length Scale Factor. t = 500 FT ASCE 7-05 TABLE 6-2 Integral Length Scale Exponent ecive = 020 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Exponent aave = 0.15 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Factor. ba18 = 0.65 ASCE 7-02 TABLE 6-2 Period Coefficient: Ct = 0.02 ASCE 7-05 Table 12.8-2 Period Coefficient: x = 0.75 ASCE 7-05 Table 12.8-2 Approximate Fundamental Period: Ta = 0.11 SEC ASCE 7-05 Eqn. 12.8-7 DESIGN LOADS: Top Sign: Height: 10.17 FT Width: 10.67 FT Point of Wind Load Application: 6.11 FT Sign Area: Ar1op 27.74 FT2 Velocity Pressure: qh = 0.00256KhIciKdV2IW Exposure Coefficient: Kh = 0.85 Kit = 1.0 Kd = . 0.85 ch, = 11.6 LB/FT2 Gust Factor G = 0.925(1+1.7g0I Q)/(1+1.7g„I2j Intensity of Turbulence: IZ = 0.228 g0 = 3.40 ASCE 7-05 Section 6.5.8.1 gv = 3.40 ASCE 7-05 Section 6.5.8.1 Equivalent height of structure: zave = 15.0 ASCE 7-05 Section 6.5.8.1 Background Response: Q = 0.956 LZ ave = 427.1 Rigid Gust Factor. G = 0.902 Clearance Ratio: Heights;ya/Height = 1.000 ASCE 7-05 Figure 6-20 Aspect Ratio: Width,;OJ Height,;9h= 1.049 ASCE 7-05 Figure 6-20 Net Force Coefficient: Cf = 1.57 ASCE 7-05 Figure 6-22 Design Wind Force: F = qhGCfAf = 456.1 LB Overturning Moment: 3018 LB -FT ASCE 7-05 Figure 6-20 ASCE 7-05 TABLE 6-3, NOTE 2 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 ASCE 7-05 TABLE 6-4 Job No. 08049 5/1/2008 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 Bottom Sign: Height: 10.17 FT Width: 10.67 FT Point of Wind Load Application: 3.81 FT Height of Top of Sign Above Grade: 10.17 FT At -bottom = 31.24 FT` Velocity Pressure: qi, = 0.00256K„ KnKdV2IW Exposure Coefficient: Kh = 0.849 ASCE 7-05 TABLE 6-3, NOTE 2 Ke = 1 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 Ka = 0.85 ASCE 7-05 TABLE 6-4 qh = 11.6 LB/FT` Gust Factor. G = 0.925(1+1.7g0I=Q)/(1+1.7g„ 1J Intensity of Turbulence: I.= 0.228 go = 3.40 ASCE 7-05 Section 6.5.8.1 g„ = 3.40 ASCE 7-05 Section 6.5.8.1 structure: ;ye = 15 ASCE 7-05 Section 6.5.8.1 Background Response: Q = 0.958 Ll ave = 427.1 Rigid Gust Factor. G = 0.903 Clearance Ratio: Height,b,„/Height,,,a,= 1.000 ASCE 7-05 Figure 6-20 Aspect Ratio: Width,,a„/Height,;y„ = 1.049 ASCE 7-05 Figure 6-20 Net Force Coefficient: C, = 1.57 ASCE 7-05 Figure 6-20 Design Wind Force: F = ghGCIAf = 514.1 LB Overturning Moment: 2220 LB -FT ASCE 7-05 Figure 6-20 TOTAL OVERTURNING MOMENT: TOTAL WIND FORCE HEIGHT OF RESULTANT FORCE: FOUNDATION DESIGN: 5239 LB -FT 970 LB 5.40 FT Lateral Bearing Pressure: 300 PSF/FT IBC TABLE 1804.2 Constrained Depth of Footing: CONSTRAINED: Combined Footing? Yes or.No? d2 = 4.25[Md(S3b)] Combined Footing? Yes Shape of Footing: Rectangular Length: 11.50 FT Width: 2.00 FT b = 11.67 FT Allowable Lateral Pressure: S1= 254.0 PSF 83 = 762.0 PSF A = 2.34`F/(S1*b) = A = 0.77 Nonconstrained Depth of Footing: d = 2.54 FT Long Dimension Parallel with Sign Job No. 08049 5/1/2008 nrIEIP@PR glE iiMcg®Amgj9 Om®. CONSULTING ENGINEERS/CIVIL AND STRUCTURAL 1519 West Valley Highway North/Suite 101/Auburn, WA 98001 Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB C804 - WE:SrrTELD SeIn1 St,,ubgTli3aS SHEET NO OF CALCULATED BY 7"`,`�� DATE CHECKED BY DATE SCALE c311\1 AAL _- ALLOY : (61•Fertz--T� . 7CRYLLC 5LLiP yrs ; �i, A I AuL.s1km-17,40a5 DEsiev Lo ADS =—> Nit .( 0.44 KC (4- ks( 1Zau►E acrickb MeiN1WS IR,Lto (� Zr ec x 0:150 vJAL . --� ®to x o, wA�-L --- ,Z,52 KS1 Fo1.1a-r V O,a70k, S.tP> ; . (7). ,z Aue410 1 lu ags = 0.734 t<•Fr _ D-784) k. t — i8.ok5I Fr S n0gZInd3 S 3(0.37 = ,5z I�V (} Q,LQ!Ai 3 Atoll' N� � .5 1R� ,1 E u f2.. Sccit'oM Mo EXU—ILS ent4P-seto�S 0 0.40 IN 3 OK (A1 -rFJttSI Qil J5 .vrY!2/"/Fr, 3.44 IN3 S = 7(0.3.7")-t- (8)(0,806 snit b0 IN3 (52q)(15.71Kzt F= PI(4) _ 16:71,3 5.7z<514 6 3wicat e � D PRODUCT 207 8'-2" #4's u u u u PIPES STUBBED Vi" INTO CABINET AND WELDED TO CAPS AT TOP AND BOTTOM OF CABINET FRAME (TYP) r, rl n r, SIGN, BY OTHERS 3° CLR 2'-3" MIN -1.-12.- 0. � - 1 41 I. - 4 - •I41 4 1..•1 -- .-I �' q I . -I411- l° M. 4 e I a 1 I - J It 1 aI- 1 1 t 4--1 I:17 1-i A 1._14. 1- 144 - r 1 d1 - I -I .a + - 4 1 ... 1. 4 1- :1 1 - f I• • A•E -(d • .7 14 1 1 .1 - 1 J• • _1 I• - 1-. -.1•P . - 4 - 6 -1 . "�3• 1 -• I. °1•I.d: LI 114 _ LJ- _ - L7r - LJ -v-1 Zit r-1 Tr"f --I- r - -i-.1-r; .. - • 4 • -1.1-21:--14-1.—.- - 4 J 1.1. 14- - 1 1 i1-• 4 • 1 -1 1-.1 1 w- ° 1 .144 • •d.. -1. 1] 1 ' 1 11 kl . 11 LJ - j.4. &J : to•. e• t - ,- V a --J .. U• 9' 6" THIS SIGN FOUNDATION ANALYSIS IS BASED ON SOIL BEARING PRESSURES TAKEN FROM THE RECOMMENDATIONS MADE IN GEOTECHNICAL REPORT #21-1-20189-004 PREPARED BY SHANNON & WILSON ON 10/27/05. IF SITE CONDITIONS DIFFER FROM THESE ASSUMPTIONS, THE ENGINEER MUST BE NOTIFIED SO THAT THE ANALYSIS MAY BE UPDATED TO MEET ACTUAL SITE CONDITIONS. #4's 3° 1 APPLY EPDXY PAINT TO ALUMINUM TUBES TO PREVENT CORROSIVE INTERACTION BETWEEN ALUMINUM AND CONCRETE. CAP BOTTOM OF TUBE AND APPLY PAINT OR PAINT TUBE INSIDE AND OUTSIDE. (TYP 2'-0° (7) 2.50 OD x 0.250 WALL 6061—T6 ALUMINUM TUBES 4- 4' .• V .Q • .4 4 • d. 4 • . -- 4 - • - - c -• 1. t 4 4 - (7) 2.00 OD x 0.250 WALL 6061—T6 ALUMINUM TUBES 1 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 PROJECT NAME: WESTFIELD SIGN FOUNDATION, SIGN AA2 633 Southcenter Boulevard, Tukwila, WA 98188 SCOPE OF WORK: Determine the column and footing requirements for the sign subject to static wind loading per the 2006 International Building Code and ASCE 7-05. All sign material and connections to column by others. DESIGN CRITERIA: Basic Wind Speed: Exposure Category: Wind Importance Factor: Total Height of Sign: Nominal Height of Atmospheric Boundary layer. Power Law Exponent: Exposure Constant: Turbulence Factor. Integral Length Scale Factor Integral Length Scale Exponent Mean Hourly Wind Exponent. Mean Hourly Wind Factor. Period Coefficient Period Coefficient Approximate Fundamental Period: DESIGN LOADS: Top Sign: Height: Width: Point of Wind Load Application: Sign Area: Velocity Pressure: Exposure Coefficient: Gust Factor. Intensity of Turbulence: V= IW = a= A,m, _ c= e= Ewe = aane = bave = G= x= Ta = 85 MPH C 0.87 8.17 FT 900 FT 9.5 15 FT 02 500 FT ASCE 7-05 FIGURE 6-1 ASCE 7-05 Section 6.5.6.3 ASCE 7-05 TABLE 6-1 ASCE 7-05 TABLE 6-2 ASCE 7-05 TABLE 6-2 ASCE 7-05 TABLE 6-2 ASCE 7-05 TABLE 6-2 ASCE 7-05 TABLE 6-2 0.20 ASCE 7-05 TABLE 6-2 0.15 ASCE 7-05 TABLE 6-2 0.65 ASCE 7-02 TABLE 6-2 0.02 ASCE 7-05 Table 12.8-2 0.75 ASCE 7-05 Table 12.8-2 0.10 SEC 8.17 8.69 3.99 A,.top = 37.86 qh = 0.00256KhKKKdV2IW Kh= K� = Kd= 0.85 1.0 0.85 qh = 11.6 LB/FT2 G = 0.925(1+1.7ga1=Q)/(1+1.7g„ la l: = 0.228 gQ = 3.40 gr = 3.40 FT FT FT FT2 Equivalent height of structure: za 8 = Background Response: Q = LZ = Rigid Gust Factor. G = Clearance Ratio: Heights;g„/Height, Aspect Ratio: Widthsig„/Heights4h = Net Force Coefficient: Cr = Design Wind Force: F = ghGC,A, = Overturning Moment HEIGHT OF RESULTANT FORCE: 15.0 0.961 427.1 0.905 1.000 1.064 1.57 624.3 LB 2746 LB -FT 4.40 FT ASCE 7-05 Eqn_ 12.8-7 ASCE 7-05 TABLE 6-3, NOTE 2 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 ASCE 7-05 TABLE 6-4 ASCE 7-05 Section 6.5.8.1 ASCE 7-05 Section 6.5.8.1 ASCE 7-05 Section 6.5.8.1 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-22 ASCE 7-05 Figure 6-20 Job No. 08049 4/29/2008 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 FOUNDATION DESIGN: Lateral Bearing Pressure: Constrained Depth of Footing: CONSTRAINED: Combined Footing? Shape of Footing: Length: Width: Allowable Lateral Pressure: A = 2.34`F1(S,`b) = Nonconstrained Depth of Footing: b= St= S3= A= d= 300 PSF/FT IBC TABLE 1804.2 Combined Footing? Yes or No? d2 = 4.25[Mg/(S3b)l Yes Rectangular 9.50 FT 2.00 FT 9.71 FT 2191 PSF 657.2 PSF 0.69 Long Dimension Parallel with Sign 2.19 FT( . o2/ -3,l Job No. 08049 4/29/2008 lanp@G'R Etaaricim o r�I CS�o CONSULTING ENGINEERS/CIVIL AND STRUCTURAL 1519 West Valley Highway North/Suite 101/Auburn, WA 98001 Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB O Q u->knc.D SHEET NO OF APP DATE ' 4/ /C) 3 CALCULATED BY CHECKED BY DATE SCALE 561 AI- : 6076 (6) 2:14! A I,, x- Tt. s (D 2„ Au INwlTlaEs Lis = 276, k •>r - V=0.0 -44K )7= 13.3 ks, (4) = ia,o M ,2, 746 K. Fr (1.2.1N/Fr act -14)4 Mom 16,o gmt TAY IhurniK. WAu_ (4) ,2,645 op x 0,2So ivau_ (6) 2 f.,.o OD x 0.25o WAt.L- teA the S 0,557(0 _ <3.22143 O,'106M 5,43 1^13 8 65 11,13 -� — _ 2.746g•F'r 614r) a6,51N3 / 3:82KSt MPREz.sI OrKh 1.125Ino 45 ,u D.8�51Aj o2so .C�1 =PiA) = 18,71<si (>S.1Ksi dot., PRnnUCT 207 2' 3' 4x4xrIHK ALUMINUM ANGLE 12'-0' =f 1 1 1 1 L__J L__ -I SIGN. BY OTHERS I %STONRSE, BY OntE r-r MIN I • USE 4043 FILLER WIRE FOR WELDS f-6' Y4. I Y -6x2 -6'__i I - SQUARE 25* (8) 9C0 x GALVANIZED A307 STEEL J -BOLTS WITH NUTS AND WASHERS pigan4 Y V Wrii4:1161 4x4 xY41HK 26'xii'xflHK ALUMINUM ANGLE AUIMINUM BASE PLATE THIS SIGN FOUNDATION ANALYSIS IS BASED ON SOIL BEARING PRESSURES TAKEN FROM THE RECOMMENDATIONS MADE IN GEOTECHNICAL REPORT #21-1-20189-004 PREPARED BY SHANNON & WILSON ON 10/27/05. IF SITE CONDITIONS DIFFER FROM THESE ASSUMPTIONS, THE ENGINEER MUST BE NOTIFIED SO THAT THE ANALYSIS MAY BE UPDATED TO MEET ACTUAL SITE CONDITIONS. RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 PROJECT NAME: WESTFIELD SIGN FOUNDATION, SIGN AB1 633 Southcenter Boulevard, Tukwila, WA 98188 SCOPE OF WORK: Determine the column and footing requirements for the sign subject to static wind loading per the 2006 International Building Code and. ASCE 7-05. All sign material and connections to column by others. DESIGN CRITERIA: Basic Wind Speed: V = 85 MPH ASCE 7-05 FIGURE 6-1 Exposure Category: C ASCE 7-05 Section 6.5.6.3 Wind Importance Factor: Iw = 0.87 ASCE 7-05 TABLE 6-1 Total Height of Sign: 12 FT Nominal Height of Atmospheric Boundary layer. z9 = 900 FT ASCE 7-05 TABLE 6-2 Power Law Exponent a = 9.5 ASCE 7-05 TABLE 6-2 Exposure Constant z,,,;,, = 15 FT ASCE 7-05 TABLE 6-2 Turbulence Factor. c = 0.2 ASCE 7-05 TABLE 6-2 Integral Length Scale Factor. Z = 500 FT ASCE 7-05 TABLE 6-2 Integral Length Scale Exponent Eave = 020 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Exponent aava = 0.15 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Factor. ba„e = 0.65 ASCE 7-02 TABLE 6-2 Period Coefficient C, = 0.02 ASCE 7-05 Table 12.8-2 Period Coefficient x = 0.75 ASCE 7-05 Table 12.8-2 Approximate Fundamental Period: Ta = 0.13 SEC ASCE 7-05 Eqn. 12.8-7 DESIGN LOADS: Top Sign: Height: 2 FT Width: 1.78 FT Point of Wind Load Application: 11.00 FT Sign Area: Acme = 3.6 FT2 Velocity Pressure: q„ = 0.00256KbKKK.V2t„ Exposure Coefficient: K„ = 0.85 ASCE 7-05 TABLE 6-3, NOTE 2 Kn = 1.0 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 14 1= 0.85 ASCE 7-05 TABLE 6-4 Cin = 11.6 LBIFT2 Gust Factor. G = 0.925(1+1.7gQizQ)!(1+1.7g,tj Intensity of Turbulence: I. = 0.228 gQ = 3.40 ASCE 7-05 Section 6.5.8.1 gv = 3.40 ASCE 7-05 Section 6.5.8.1 Equivalent height of structure: Background Response: nave = Q= Lave = Rigid Gust Factor. G = Clearance Ratio: HeightgyJHeightthw = Aspect Ratio: Wdthsig„/Heightsy,= Net Force Coefficient: C, = Design Wind Force: F = ghGCfA, = Overturning Moment: 15.0 ASCE 7-05 Section 6.5.8.1 0.966 427.1 0.907 0.167. ASCE 7-05 Figure 6-20 0.891 ASCE 7-05 Figure 6-20 1.81 ASCE 7-05 Figure 6-20 67.9 LB 747 LB -FT ASCE 7-05 Figure 6-20 Job No. 08049 4130/2008 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 Bottom Sign: Height: Width: Point of Wind Load Application: Height of Top of Sign Above Grade: AFbottom = Velocity Pressure: qt, = 0.00256KhKKKdV21„, Exposure Coefficient: Kn = 0.849 K2 = 1 Ka = 0.85 qn = 11.6 LB/FT` Gust Factor. G = 0.925(1+1.7g0IzQ)/(1+1.7g„IZ) Intensity of Turbulence: = 0.228 10 FT 2.25 FT 5 FT 10 FT 22.5 FT` 90 = 3.40 9v = 3.40 Equivalent height of structure: zave = Background Response: Q = Lz ave = Rigid Gust Factor. G = Clearance Ratio: Height ,/Height„= Aspect Ratio: Widthes„/Heights;y„= Net Force Coefficient: Cr = Design Wind Force: F = gnGCA = Overtuming Moment: TOTAL OVERTURNING MOMENT: TOTAL WIND FORCE: HEIGHT OF RESULTANT FORCE FOUNDATION DESIGN: Lateral Bearing Pressure: Constrained Depth of Footing: CONSTRAINED: Combined Footing? Shape of Footing: Length: Width: Allowable Lateral Pressure: A = 2.34'F/(S1'b) = Nonconstrained Depth of Footing: b= S� = S3 = A= d= 15 0.968 427.1 0.908 0.225 0.225 1.85 ASCE 7-05 TABLE 6-3, NOTE 2 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 ASCE 7-05 TABLE 6-4 ASCE 7-05 Section 6.5.8.1 ASCE 7-05 Section 6.5.8.1 ASCE 7-05 Section 6.5.8.1 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-20 438.9 LB 2195 LB -FT ASCE 7-05 Figure 6-20 2942 LB -FT 507 LB 5.80 FT 300 PSF/FT Combined Footing? Yes or No? d2 = 425[M9f(S3b)) Yes Square 2.50 FT 2.50 FT 3.54 FT 317.0 PSF 951.0 PSF 1.06 3.17 FT (231-3" •••0l'-) Job No. 08049 4/3012008 G3urip®u rbil®milmg, BE®, CONSULTING ENGINEERS/CIVIL AND STRUCTURAL 1519 West Valley Highway North/Suite 101/Auburn, WA 98001 • Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB Om/49—V/ESTF34-ab 516ry -�uua�a-�#7)3,ts SHEET NO ASP OF ,j% / ASP DATE " 4/ 105 CALCULATED BY CHECKED BY DATE SCALE SOF Sir, 5� Ate' - i T27 (2) KL1(/` 4TZ-iK. 41/44cliaS - 467 iN4.7 taws vqD DEN9N LPDS M ,V91.14'Fr V=a50?K TeNrS«N, �( _ 2.6iiitic: F-r_6z-'"/ = 11,43 ksi S (2)(1.GW3) _(111.c.si) = 14,7 test' (>11.0.kst 3 M,PTZE ^ '_ �- -Bim(2 Ks► _ �GS� (aj.® k.5► ®k� 919 w& cam: Qut+Zj = �.a�zk Fr YIzl�F6 = C,241 K. ."12'2504/ tr i 40,43 r=t 2 s -t end (0,�0-i)(4"X8►NysKs = 7, 08 K (6:24.K D PRODUCT 207 Rupert Engineering, Inc. 1519 West Valley Highway North, Suite 101 Auburn, WA 98002 Anchorage Strength Design Calculations: Project: Westfield Sign Foundations, Sign AB1 REI Job #08049 Given: Bolt Type: Outside Diameter of Anchor: Effective Anchor Embedment Depth: Smallest Edge Distance:cmin 3 0!r Number of Bolts Resisting Tension Force: ntension 1_ Number of Bolts Resisting Shear Force: 'shear Effective Cross-sectional Area of Bolt: Ase _ (da)2' ] Ase = 0.307 m- 4 5/8' A307 J BOfi: da := 8 in := 12 Specified Tensile Strength of Anchor Steel: 4129108 z for threaded bo ts, ASe = do _ 0.9743 where = threads/inch 4 nt Specified Compressive Strength of Concrete: fprime c - 2500- - n := 45000 psi Ibfj Factored Tension Load: Factored Shear Load: 2942.12 Nu :— Ib Nu = 78453 lbf 4.5 := 507Ib 2 Tensile Strength: on = minimum calculated value of Os, (I)Ncb or (1)Ncbg, & 01pn Nominal Anchor Strength, Ns: Ns ntension 6900 1b Tabie7 2 AISC Steel Construction ManuaN Ns.max := ntension'Ase'fut =41417.5lbf Ns.max Ns := min(Ns> Ns.max) Ns = 20700 lbf := 0.75 (I)Ns Ns = 15525 lbf Nominal Concrete Breakout Strength, Nr}, or N AN Nominal Strength = -No W� `2 tV3'Nb Limited Effective Anchor Length: Projected Failure Surface Area: Projected Failure Surface Area of a Single Anchor. Coefficient for Basic Breakout Strength in Tension: Basic Concrete Breakout Strength in Tension: het prime := max` 1.5 AN 30in•30in 19.5in 4•7in0 AN = 900 int 3 hef.prime = 13 in (The base of the rectilinear geometrical figure that results from ANo 9hef.prime projecting the failure surface -°-- outward 1.5hef from the centerlines ANo = 1521 in2 of the anchor) k := 2 (24 for cast -in anchors; 17 for post -installed anchors) 1.5 Nb = k J fprime.c' hef Nh k • 2500.13 1' Eccentricity of normal force on a group of anchors: Eccentricity Modification Factor Edge Distance Modification Factor. Cracking Modification Factor: Nominal Concrete Breakout Strength: Nominal Pullout Strength, Nps Distance from the Inner Surface of a J -bolt to the outer tip of the J -bolt: �Nn = min(4)Ns-Nss,, Ncb-Ncb-Ibf,n tension-4)Np•NO 4Nn = 15525 lbf � `7� & 5 ••• J -) Nb = 56246.6 eprime N 9 (valid for e'N < s/2) if ti'ec.N = 1 Wed.N if t eprime.N' 0, i ,1 2eprime. N 1+ 3 hef cmin < 1.5hef, i cmin 0.7 + 0.3• 1.5hef Wed.N=0.8 Wc.N 1.25 (1.25 for cast -in anchors; 1.4 for post-instafted anchors; 1.0 where analysis indicates cracking at service bad levels) AN Ncb 'Vec.N'Wed.N'Wc.N'Nb ANo Ncb = 31201.9 Ncb + Ncb Ncb •Ibf = 3281251bf eh := 12 ill Np := 0.9fprime.c'eh'da N = 16875 Ibf �N.., 4) Np Np =11812.5 Ibf Shear Strength: 4 V� = minimum calculated value of OVs, 4Vcb or 4Vcbg. & OVcp Nominal Anchor Strength, Vsi vs nshear'36801b4 Vsmax nshear'0 6•ASe•fu Vs := min (Vs , Vsmax) Vs = 29440 Ibf 4Vs•0.65 4Vs"Vs = 191361bf Nominal Concrete Breakout Strength, Vcb or Vcbg- Distance from the center of an anchor shaft to the edge of concrete in the direction of the shear force: Projected Concrete Failure Area of an Anchor or Group of Anchors: Projected Concrete Failure Area of One Anchor When Not Limited by Comer Influences, Spacing, or Member Thickness: Load Bearing Length of Anchor for Shear. Basic Concrete Shear Breakout Strength: := 10.Sir AVc = 472.5 in2 AVS := 4.5ca12 AVco = 496A in2 IQ := 12in le= 12in 7 X 0.2 le 1.5 Vb = 7' d fprime.c'Cal i a/ Vb = 17000.1 Eccentricity of Shear Force on a Group of Anchors; the Distance Between the Point of Shear Force Application and the Centroid of the Group of Anchors Resisting Shear in the Direction of the Applied Shear a e pnmetV...... Eccentricity Modification Factor 1 1 Wec.V if eprime.V' 0> , 1 Zeprime.V l+ Wec.V = 1.00 3•cal Distance from Center of an Anchor Shaft to the Edge of Concrete in the Direction Orthogonal to c1: Edge Distance Modification Factor. Cracking Modification Factor: Member Height Modification Factor. Nominal Concrete Breakout Strength in Shear of a Single Anchor Shear Strength of Group of Anchors Concrete Pryout Strength, Vcp: Pryout Strength Coefficient Nominal Concrete Pryout Strength: Total Factored Pryout Strength for Anchor Group: Vn:= min( Vs•Vs> Vcb'Vcb•Ibf,(1)Vcp•V0•Ibf) 4Vn = 12013.4 lbf <} scr7 L F •• • O.) Tensile and Shear Force Interaction: Vu = 507 lbf 0.2•dVn = 2402.7 Ibf Nu = 7845.3 lbf > 0.2.4 Nn = 3105 Ibf Nu + Vu = 0.548 < 1.2 4Nn 4Vn ca2: 3 ir1 '`ed.V := if 1,0.7+ 03• 1.5•cal ca2 = 0.76 `kc V:^:. l4 analysis indicates no cracking at service Toads (1.0 for anchors in cracked concrete with no supplementary reinforcement or edge reinforcement smaller than a no. 4 bar; 1.2 for anchors in cracked concrete with supplementary reinforcement of a no. 4 bar or greeater between the anchor and the edge; 1.4 for anchors in cracked concrete with supplementary reinforcement of a no. 4 bar or greater between the anchor and the edge, and with the supplementary reinforcement enclosed within stirrups spaced at not more than 4 in.) h39uf a 1 5cai ,1 ha i wh.V := if ha < 1.5ca1, t'h.V = 1.00 AVc Vcb :-'ec.V''Ved.V*Tc.V'Wh.V'Vb A `' Vco Vcb = 17162 \/rh 0.7d 4)Vcb'Vcb.lbf = 12013.4 lbf kcp := if(hef < 2.5in , 1.0, 2.0) nshear Vcp := kcp-Ncb ntension Vcp = 166410.1 4Vcp: 07t IVcp•Vcp•Ibf = 1164871bf .( T U. i--rEMslakb puzAlkaLe.. o K) J -Bolt Development Length Worksheet Project Name: Westfield Sign Foundations, Sign A131 Job Number: 08049 Design Based on ACI 318 4000q a := Lc! y := 0 5.1 ub := fe := 250Ci p := 1.0 := Kt .= Oin 7c+Ktr c Ktr'\ x if > 2.5,2.5, db db 1 d (3• 40 rf— c 'hook= 8'db I hook50'j to := 1 tgrout 0-75I twasher tnut 1 Ivert := + tpl tgrout twasher tnut + .Sin Ivert =1675nl THIS SIGN FOUNDA1ION ANALYSIS IS BASED ON SOIL BEARING PRESSURES TAKEN FROM THE RECOMMENDATIONS MADE IN GEOTECHNICAL REPORT #21-1-20189-004 PREPARED BY SHANNON & WILSON ON 10/27/05. IF SITE CONDITIONS DIFFER FROM THESE ASSUMPTIONS, THE ENGINEER MUST BE NOTIFIED SO THAT THE ANALYSIS MAY BE UPDATED TO MEET ACTUAL SITE CONDI11ON& 3' 9i' 1O'-6 �n / 2'-9MIN r r1 1-61 .•I -1 i•1 •I t •I 1- r •1 ? 1 .1' h tar. 1 -1 .1 1- :p.1 --1.1 1 1• r !• 1 C •1 -I i .1 1 -I ie 14ak 1'I4 1•- 13..1• -t 1 NIA •.r• 1 1- I.1ty t'- 1mssr 1 -u u?%: (3) 2'0 SCH 80 6061-T6 ALUMINUM PIPES (-0" SIGNS, BY OTHERS APPLY EPDXY PAINT TO ALUMINUM 1UBES TO PREVENT CORROSIVE INTERACTION BETWEEN ALUMINUM AND CONCRETE. CAP BOTTOM OF TUBE AND APPLY PAINT OR PAINT TUBE INSIDE AND OUTSIDE (TYP) 111Kr 4) 2.5'0 SCH 80 6061-T6 ALUMINUM PIPES RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Aubum, WA 98001 PROJECT NAME: WESTFIELD SIGN FOUNDATION, SIGN AD1 633 Southcenter Boulevard, Tukwila, WA 98188 SCOPE OF WORK: Determine the column and footing requirements for the sign subject to static wind loading per the 2006 International Building Code and ASCE 7-05. All sign material and connections to column by others. DESIGN CRITERIA: Basic Wind Speed: V = 85 MPH ASCE 7-05 FIGURE 6-1 Exposure Category: C ASCE 7-05 Section 6.5.6.3 Wind Importance Factor. IW = 0.87 ASCE 7-05 TABLE 6-1 Total Height of Sign: 10.54 FT Nominal Height of Atmospheric Boundary layer. zg = 900 FT ASCE 7-05 TABLE 6-2 Power Law Exponent: a = 9.5 ASCE 7-05 TABLE 6-2 Exposure Constant z„i„ = 15 FT ASCE 7-05 TABLE 6-2 Turbulence Factor. c = 02 ASCE 7-05 TABLE 6-2 Integral Length Scale Factor. Z = 500 FT ASCE 7-05 TABLE 6-2 Integral Length Scale Exponent Earn = 0.20 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Exponent aava = 0.15 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Factor. ba,,, = 0.65 ASCE 7-02 TABLE 6-2 Period Coefficient Ct = 0.02 . ASCE 7-05 Table 12.8-2 Period Coefficient: x = 0.75 ASCE 7-05 Table 12.8-2 Approximate Fundamental Period: Ta = 0.12 SEC ASCE 7-05 Eqn. 12.8-7 DESIGN LOADS: Top Sign: Height: 10.54 FT Width: 3.67 FT Point of Wind Load Application: 5.20 FT Sign Area: Af o = 24.48 FT2 Velocity Pressure: qh = 0.00256KhKziKdV2I,w Exposure Coefficient: Kh = 0.85 ASCE 7-05 TABLE 6-3, NOTE 2 Kit = 1.0 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 Kd = 0.85 ASCE 7-05 TABLE 6-4 qh = 11:6 LBIFT2 Gust Factor. G = 0.925(1+1.7gat2Q)/(1+1.7g„ I=) Intensity of Turbulence: I. = 0.228 ga = 3.40 ASCE 7-05 Section 6.5.8.1 g„ = 3.40 ASCE 7-05 Section 6.5.8.1 Equivalent height of structure: zave = 15.0 Background Response: Q = 0.965 L= aye = 427.1 Rigid Gust Factor. G = 0.907 Clearance Ratio: Heights;g„Meighttoat= 1.000 Aspect Ratio: Widths;g,/Heightsig„= 0.348 Net Force Coefficient: Cf = 1.6 Design Wind Force: F = q,,GC¢y = 412.3 LB Overturning Moment: 2361 LB -FT HEIGHT OF RESULTANT FORCE: 5.73 FT ASCE 7-05 Section 6:5.8.1 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-22 ASCE 7-05 Figure 6-20 Job No. 08049 5/1/2008 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Aubum, WA 98001 FOUNDATION DESIGN: Lateral Bearing Pressure: 300 PSF/FT IBC TABLE 1804.2 Constrained Depth of Footing: Combined Footing? Yes or No? CONSTRAINED: d2 = 4.25[11;/(S3b)1 Combined Footing? Yes Shape of Footing: Rectangular Length: 4.00 FT Long Dimension Parallel with Sign Width: 1.50 FT b= 4.27 FT Allowable Lateral Pressure: S1 = 272.6 PSF S3 = 817.8 PSF A = 2.34*F/(S,'b) = A = 0.83 Nonconstrained Depth of y ►1 Footing: d = 2.73 FT < Qk\ Job No. 08049 51112008 ,91)-I-5.544_162.1*6 CONSULTING ENGINEERS/CIVIL AND STRUCTURAL 1519 West Valley Highway North/Suite 101/Auburn, WA 98001 Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB 08 0461 ` VG't<G1_'1 gl (j 7 %Al 7 -rd l AVI rt)A S SHEET NO OF / CALCULATED BY AEPDATE5 /l/ It CHECKED BY DATE SCALE �►c;►� AD1(c) eats (Z1 --t-0., G p 4 0.8515 g L = 10,5ke Q, = 1o,50 - 5.76' = 'be = 4(©,1x91114) -I- 3 60,-,37/AiSoix, (0,396 k..is.76))(12), z pyi0,54.47) +4767 Oz4.6 6 (qC7tco K.,,s 2.4t) !N45 5.&Ct IAO 10,547 62* 34o im 2,4/ i '- 2,4/ ►N4 EMU 35,1 FoS. _ Emu, ,. /� 5 p1Z'AI�Fi = O. = 3.641:11N (2.41ia' = 10,3/N4 0.N Ri (41) 011/2 g0 P S _ (1 1,R2►,v4) -t 3(0,,e68nv4) 90, 3 044 .RE Vi - W1/&o s 1? = O.`I 12 K : CL = 10, 54 - 5,20 = 5,34 L o ;xao, /co 4<si7(toziA14) ®, = 13.s o v. D PRODUCT 207 14'-0' THIS SIGN FOUNDATION ANALYSIS IS BASED ON SOIL BEARING PARES TAKEN FROM THE RECOIA ENDA110NS MADE IN GEOTECHNICAL REPORT /21-1-201139-004 PREPARED BY SHANNON & WILSON ON 10/27/05. IF SITE CONDI110NS DIFFER ROM THESE ASSUMPTIONS. THE ENGINEER MUST BE NO1IFIED SO THAT THE ANALYSIS MAY BE UPDATED TO MEET ACTUAL S TE CONDITIONS. 5'0 SCH 40 6061-16 ALUMINUM PIPES (0.256' WALL) OR 4.91 x 0.375 WALL 6061-T6 ALUMINUM TUBES 3' faR e '' 4` . , APPLY EPDXY PAINT TO ALUMINUM TUBES TO •* * PREVENT CORROSIVE ? •-, • . INTERACTION BEEN r.: l .1 : ALUMINUM AND r CONCRETE. CAP -.;::,,-'1::-.1-1: raR BOT10M OF TUBE AND I ► TUBE INSIDE AND 2.-0' t OUTSIDE. (TYP) APPLY PAINT OR PAINT 0.0': RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 PROJECT NAME: WESTFIELD SIGN FOUNDATION, SIGN AF1 633 Southcenter Boulevard, Tukwila, WA 98188 SCOPE OF WORK: Determine the column and footing requirements for the sign subject to static wind loading per the 2006 International Building Code and ASCE 7-05. All sign material and connections to column by others. DESIGN CRITERIA: Basic Wind Speed: V = 85 MPH ASCE 7-05 FIGURE 6-1 Exposure Category: C ASCE 7-05 Section 6.5.6.3 Wind Importance Factor. IW = 0.87 ASCE 7-05 TABLE 6-1 Total Height of Sign: 14 FT Nominal Height of Atmospheric Boundary layer. zg = 900 FT ASCE 7-05 TABLE 6-2 Power Law Exponent a = 9.5 ASCE 7-05 TABLE 6-2 Exposure Constant z„d, = i5 FT ASCE 7-05 TABLE 6-2 Turbulence Factor. c = 02 ASCE 7-05 TABLE 6-2 Integral Length Scale 1= 500 FT ASCE 7-05 TABLE 6-2 Factor. Integral Length Scale Exponent Eave = 0.20 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Exponent cave= 0.15 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Factor. b.= 0.65 ASCE 7-02 TABLE 6-2 Period Coefficient: Ct = 0.02 ASCE 7-05 Table 12.8-2 Period Coefficient: x = 0.75 ASCE 7-05 Table 12.8-2 Approximate Fundamental Period: Ta = 0.14 SEC ASCE 7-05 Eqn. 12.8-7 DESIGN LOADS: Top Sign: Height: 14 FT Width: 2.88 FT Point of Wind Load Application: 8.20 FT Sign Area: At -top = 21.33 FT2 Velocity Pressure: qh = 0.00256KhKAKdV2IW Exposure Coefficient: Kh = 0.85 ASCE 7-05 TABLE 6-3, NOTE 2 Kzt = 1.0 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 Ka = 0.85 ASCE 7-05 TABLE 6-4 qh = 11.6 LBJFT2 Gust Factor. G = 0.925(1+1.7g0IZQ)/(1+1.79„ I7.) Intensity of Turbulence: I= = 0.228 ga = 3.40 ASCE 7-05 Section 6.5.8.1 g„ = 3.40 ASCE 7-05 Section 6.5.8.1 Equivalent height of structure: za„B = 15.0 Background Response: Q = 0.961 LZ ave = 427.1 Rigid Gust Factor. G = 0.905 Clearance Ratio: Height,;g„IHeightt„a,= 1.000 Aspect Ratio: Width,y,/Height.;y„= 0.206 Net Force Coefficient: Cr = 1.65 Design Wind Force: F = ghGCfAf = 369.7 LB Overturning Moment 3290 LB -FT HEIGHT OF RESULTANT FORCE: 8.90 FT ASCE 7-05 Section 6.5.8.1 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-20 ASCE 7-05 Figure 6-22 ASCE 7-05 Figure 6-20 Job No. 08049 51112008 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 FOUNDATION DESIGN: Lateral Bearing Pressure: 300 PSF/FT IBC TABLE 1804.2 Constrained Depth of Footing: Combined Footing? Yes or No? CONSTRAINED: d2 = 4.25[My/(S3b)] Combined Footing? Yes Shape of Footing: Square Length: 2.00 FT Width: 2.00 FT b= 2.83 FT Allowable Lateral Pressure: S1 = 342.4 PSF S3 = 1027.2 PSF A = 2.34'F/(S1'b) = A = 0.89 Nonconstrained Depth of �i Footing: d = 3.42 FT e --� Job No. 08049 51112008 aupG rilagaitago Dna, CONSULTING ENGINEERS/CIVIL AND STRUCTURAL 1519 West Valley Highway North/Suite 101/Auburn, WA 98001 Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB 05gi_1- Wear -1 Scr! . LA1tciJG]7U`= SHEET NO AEP 4E P DATE 4/2a l CALCULATED BY CHECKED BY DATE SCALE 1c-.1,4 AF ALuoY • 6061 ac.pror•a- = 54419 9zik4, 0;$75 WeAu._? 1,7t 'z/9 a l is M =165 K, Fr - IEN)5101.4 Roz. PcuALD Tu,BE =i 'sc t (4j =-18.40 4<zi M 143 k' g7 -6z 4/Fr) IfifiliLLe=o a -c rtrn e MODULUS — F = = 1.16_ IN 3 3CA-14Pam.PIPE - =&Ak>110 IN d1C) Fay ScuuAR = CA) . ,147 -#CS - / m _ 1-65 u.Fr1621,"/Fr) . 3,24 Kz i (41q.7w4i--c dlL COMDR t Row1/416-11.4a:4.. ate. ... Rb 7T 10.3 = /101) = /6.7 K � -165 61 56 5,qz 1- = I2(`!/ _ /6 Ksl (7 �,2Q lG51 : • � c.. 6.02,N3 T --4(o/ja OA61.`i>+ 0.67' = 0:18, K•FT Tri (o.is KiFrY11-t4/>^r)(4.2 iw) "Ra.4D�u �J = �5 '. = 0 `1'3 KS( Q • -pj*— Tr. (0, is 1c•F`r-�C12►"'/��,�KttN� _ 0. kS1 cT 17.Q 1144 �.. 3.63 Ks b' dK) , • D PRODUCT207 C dp® Ih®QUuaJ9 Ona, CONSULTING ENGINEERS/CIVIL AND STRUCTURAL 1519 West Valley Highway North/Suite 101/Auburn, WA 98001 Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB "M4 q-WES-r Lb cSi(1 "F39uGoATUK S SHEET NO OF CALCULATED BY CHECKED BY DATE SCALE ?�16' DATE /1 t 8 1 311, AF1 (couT-_) P _ q5.1 1.15 L= 14L7 a= 14,o' - q,7�,' = .1.2' E _ /01 /Do Ks/ Z- 1.b1044 rx = (d,4145"/.4:,1+0 -422.7Y-6'44 )02.)byt4o) ra 607100 Kis 84'0 Q.73 0►J (xcE, (/E. 150 E= 14.07(12.1m/Pr = 1,TZ ►N b \ too `Raab 1 — �(L_a"J� (2L+a) 44, 4,ZZ1 62.1A1/F66.6071oo ttstY1.1Z1M) 1,,4 . 1s�.�tlrAr Loans — M = 1:& K•F r- a / az/ = 5.8' V = 0, task — Z (©18514/. 8, ' I ii^i/Frr 6 �01oa 2�C���+ 5.e5')(12.04/F7-.) r fcsl)(15,2.rn1 _. o.7gfr 212_3 (`? ) E 0,7/ 1/�2- (0,79) 1.°114 �ozZ, 'is& sc� x 0,37s WALL_ 1� =12.0 � 5M� � fi2 =.160 (750 D PRODUCT207 TABLE 25 -ROUND TUBE The listed sizes are provided for the convenience of the designer; however, availability should be checked before making the final design selection. Additional sizes and shapes may be available from suppliers. Designation Inside OD x Wall Diam Area Weight in. in. in. in.2 lb/ft Section Properties S r in.3 in. 0.375 OD x 0.035 Wall 0.375 OD x 0.049 Wall 0.375 OD x 0.058 Wall 0.375 OD x 0.065 Wall 0.305 0.277 0.259 0.245 0.0374 0.0502 0.0578 0.0633 0.0440 0.0590 0.0679 0.0745 0.0006 0.0007 0.0007 0.0008 0.0029 0.0036 0.0040 0.0042 0.121 0.117 0.114 0.112 0.500 OD x 0.028 Wall 0.500 OD x 0.035 Wall 0.500 OD x 0.049 Wall 0.500 OD x 0.058 Wall 0.500 OD x 0.065 Wall 0.444 0.430 0.402 0.384 0.370 0.0415 0.0511 0.0694 0.0805 0.0888 0.0488 0.0601 0.0817 0.0947 0.104 0.0012 0.0014 0.0018 0.0020 0.0021 0.0046 0.0056 0.0071 0.0080 0.0086 0.167 0.165 0.160 0.158 0.156 0.625 OD x 0.028 Wall 0.625 OD x 0.035 Wall 0.625 OD x 0.049 Wall 0.625 OD x 0.058 Wall 0.625 OD x 0.065 Wall 0.569 0.555 0.527 0.509 0.495 0.0525 0.0649 0.0887 0.103 0.114 0.0618 0.0763 0.104 0.122 0.134 0.0023 0.0028 0.0037 0.0042 0.0045 0.0075 0.0091 0.0119 0.0134 0.0145 0.211 0.209 0.204 0.202 0.199 0.750 OD x 0.035 Wall 0.750 OD x 0.049 Wall 0.750 OD x 0.058 Wall 0.750 OD x 0.065 Wall 0.750 OD x 0.083 Wall 0.680 0.652 0.634 0.620 0.584 0.0786 0.108 0.126 0.140 0.174 0.0925 0.127 0.148 0.165 0.205 0.0050 0.0067 0.0076 0.0083 0.0098 0.0134 0.0178 0.0203 0.0221 0.0262 0.253 0.248 0.246 0.243 0.238 0.875 OD x 0.035 Wall 0.875 OD x 0.049 Wall 0.875 OD x 0.058 Wall 0.875 OD x 0.065 Wall 0.805 0.777 0.759 0.745 0.0924 0.127 0.149 0.165 0.109 0.150 0.175 0.195 0.0082 0.0109 0.0125 0.0137 0.0187 0.0249 0.0285 0.0312 0.297 0.293 0.290 0.287 1.00 OD x 0.035 Wall 1.00 OD x 0.049 Wall 1.00 OD x 0.058 Wall 1.00 OD x 0.065 Wall 1.00 OD x 0.083 Wall 1.00 OD x 0.095 Wall 0.930 0.902 0.884 0.870 0.834 0.810 0.106 0.146 0.172 0.191 0.239 0.270 0.125 0.172 0.202 0.225 0.281 0.318 0.0124 0.0166 0.0191 0.0210 0.0253 0.0280 0.0247 0.0331 0.0382 0.0419 0.0507 0.0559 0.341 0.337 0.334 0.331 0.326 0.322 • 1.25 OD x 0.063 Wall 1.25 OD x 0.078 Wall 1.25 OD x 0.094 Wall 1.25 OD x 0.125 Wall 1.12 1.09 1.06 1.00 0.233 0.287 0.341 0.442 0.282 0.338 0.402 0.520 0.0412 0.0491 0.0578 0.0708 0.0659 0.0785 0.0925 0.113 0.420 0.413 0.410 0.400 1.50 OD x 0.063 Wall 1.50 OD x 0.078 Wall 1.50 OD x 0.094 Wall 1.50 OD x 0.125 Wall 1.50 0D x 0.156 Wall 1.50 OD x 0.188 Wall 1.50 OD x 0.219 Wall 1.50 OD x 0.250 Wall 1.37 1.34 1.31 1.25 1.19 1.12 1.06 1.00 0.282 0.348. 0.414 0.540 0.660 0.773 0.881 0.982 0.342 0.410 0.488 0.635 0.775 0.911 1.03 1.15 0.0730 0.0883 0.103 0.129 0.151 0.170 0.186 0.199 0.0973 0.118 0.137 0.172 0.201 0.227 0.248 0.266 0.509 0.503 0.498 0.488 0.478 0.469 0.460 0.451 1.75 OD x 0.063 Wall 1.75 OD x 0.078 Wall 1.75 OD x 0.094 Wall 1.75 OD x 0.125 Wall 1.75 OD x 0.156 Wall 1.75 OD x 0.188 Wall 1.75 OD x 0.219 Wall 1.75 OD x 0.250 Wall 1.62 1.59 1.56 1.50 1.44 1.37 1.31 1.25 0.331 0.409 0.488 0.638 0.782 0.920 1.05 1.18 0.400 0.482 0.575 0.751 0.919 1.09 1.23 1.39 0.118 0.144 0.168 0.212 0.251 0.285 0.315 0.341 0.135 0.165 0.192 0.242 0.287 0.326 0.360 0.389 0.597 0.593 0.587 0.576 0.566 0.556 0.547 0.538 VI -28 January 2000 TABLE 25 -ROUND TUBE (Cont.) The listed sizes are provided for the convenience of the designer; however, availability should be checked before making the final design selection. Additional sizes and shapes may be available from suppliers. Designation Inside OD x Wall Diam Area Weight in. in. in. in. Ib/ft Section Properties I S r in.4 in.3 in. 2.00 OD x 0.063 Wall 2.00 OD x 0.078 Wall 2.00 OD x 0.094 Wall 2.00 OD x 0.125 Wall 2.00 OD x 0.156 Wall 2.00 OD x 0.188 Wall 2.00 OD x 0.219 Wall 2.00 OD x 0.250 Wall 2.00 OD x 0.313 Wall 2.00 OD x 0.375 Wall 2.00 OD x 0.438 Wall 1.87 1.84 1.81 1.75 1.69 1.62 1.56 1.50 1.37 1.25 1.12• 0.380 0.470 0.561 0.736 0.905 1.07 1.22 1.37 1.66 1.91 2.15 0.460 0.554 0.662 0.866 1.06 1.26 1.44 1.62 1.95 2.25 2.53 0.179 0.216 0.256 0.325 0.387 0.443 0.493 0.537 0.610 0.666 0.707 0.179 0.216 0.256 0.325 0.387 0.443 0.493 0.537 0.610 0.666 0.707 0.685 0.678 0.675 0.664 0.654 0.644 0.635 0.625 0.607 0.590 0.574 2.50 OD x 0.063 Wall 2.50 OD x 0.078 Wall 2.50 OD x 0.094 Wall 2.50 OD x 0.125 Wall 2.50 OD x 0.156 Wall 2.50 OD x 0.188 Wall 2.50 OD x 0.219 Wall 2.50 OD x 0.250 Wall 2.50 OD x 0.313 Wall 2.50 OD x 0.375 Wall 2.50 OD x 0.438 Wall 2.50 OD x 0.500 Wall 2.37 2.34 2.31 2.25 2.19 2.12 2.06 2.00 1.87 1.75 1.62 1.50 0.479 0.591 0.709 0.933 1.15 1.36 1.57 1.77 2.15 2.50 2.84 3.14 0.579 0.698 0.836 1.10 1.35 1.61 1.85 2.08 2.54 2.94 3.34 3.70 0.356 0.428 0.514 0.659 0.794 0.917 1.03 1.13 1.31 1.46 1.58 1.67 0.285 0.342 0.411 0.528 0.635 0.733 0.823 0.906 1.05 1.17 1.26 1.34 0.862 0.850 0.851 0.841 0.831 0.820 0.810 0.800 0.781 0.763 0.745 0.729 3.00 OD x 0.063 Wall 3.00 OD x 0.078 Wall 3.00 OD x 0.094 Wall 3.00 OD x 0.125 Wall 3.00 OD x 0.156 Wall 3.00 OD x 0.188 Wall 3.00 OD x 0.219 Wall 3.00 OD x 0.250 Wall 3.00 OD x 0.313 Wall 3.00 OD x 0.375 Wall 3.00 OD x 0.438 Wall 3.00 OD x 0.500 Wall 3.00 OD x 0.625 Wall 3.00 OD x 0.750 Wall 2.87 2.84 2.81 2.75 2.69 2.62 2.56 2.50 2.37 2.25 2.12 2.00 1.75 1.50 0.577 0.714 '0.856 1.13 1.40 1.66 1.91 2.16 2.64 3.09 3.52 3.93 4.66 5.30 0.681 0.842 1.01 1.33 1.64 1.95 2.25 2.54 3.11 3.64 4.15 4.62 5.48 6.24 0.622 0.760 0.905 1.17 1.42 1.65 1.86 2.06 2.41 2.72 2.98 3.19 3.52 3.73 0.415 0.506 0.603 0.779 0.944 1.10 1.24 1.37 1.61 1.81 1.98 2.13 2.34 2.49 1.04 1.03 1.03 1.02 1.01 0.997 0.986 0.976 0.957 0.938 0.919 . 0.901 0.868 0.839 3.50 OD x 0.156 Wall 3.50 OD x 0.250 Wall 3.50 OD x 0.375 Wall 3.50 OD x 0.500 Wall 3.19 3.00 2.75 2.50 1.64 2.55 3.68 4.71 1.93 3.00 4.33 5.54 2.30 3.39 4.56 5.45 1.31 1.94 2.61 3.11 1.18 1.15 1.11 1.08 4.00 OD x 0.125 Wall 4.00 OD x 0.156 Wall 4.00 OD x 0.219 Wall 4.00 OD x 0.250 Wall 4.00 OD x 0.500 Wall 4.00 OD x 0.625 Wall 4.00 OD x 0.750 Wall 3.75 3.69 3.56 3.50 3.00 2.75 2.50 1.52 1.89 2.60 2.95 5.50 6.63 7.66 1.79 2.22 3.06 3.46° 6.47 7.79 9.01 2.86 3.49 4.66 5.20 8.59 9.76 10.6 1.43 1.75 2.33 2.60 4.30 4.90 5.32 1.37 1.36 1.34 1.33 1.25 1.21 1.18 4.50 OD x 0.188 Wall 4.50 OD x 0.250 Wall 4.50 OD x 0.375 Wall 4.50 OD x 0.500 Wall 4.50 OD x 0.750 Wall 4.12 4.00 3.75 3.50 3.00 2.54 3.34 4.86 6.28 8.84 3.00 3.93 5.72 7.39 10.4 5.92 7.56 10.4 12.8 16.2 2.63 3.36 4.63 5.67 7.18 1.53 1.51 1.46 1.43 1.35 January 2000 VI -29 TABLE 16 -ANGLES -EQUAL LEGS The listed sizes are provided for the convenience of the designer; however, availability should be checked before making the final design selection. Additionalsizes and shapes may be available from suppliers. Axis x -x. y -y Axis z -z Designation 1 S r s x L d x b x t Weight Area ri r. Iy. S, ry x, y 1Z r, in. in. in. Ib/ft in.= in. in. in.° in.3 in. in. in.' in. L 1.5 x 1.5 x 0.125 0.43 0.36 0.188 0.125 0.074 0.068 0.45 0.41 0.031 0.29 L 1.5 x 1.5 x 0.25 0.81 0.69 0.188 0.125 0.135 0.130 0.44 0.46 0.057 0.29 L 1.75 x 1.75 x 0.125 0.58 0.42 0.188 0.125 0.121 0.094 0.53 0.47 0.050 0.34 L 1.75 x 1.75 x 0.250 0.96 0.81 0.188. 0.125 0.223 0.181 0.52 0.52 0.093 0.34 L 1.75 x 1.75 x 0.375 1.38 1.17 0.188 0.125 0.306 0.259 0.51 0.57 0.134 0.34 L 2 x 2 x 0.125 0.57 0.49 0.250 0.125 0.18 0.13 0.61 0.53 0.08 0.40 L 2 x 2 x 0.250 1.11 0.94 0.250 0.125 0.34 0.24 0.60 0.58 0.14 0.39 L 2 x 2 x 0.375 1.59 1.37 0.250 0.125 0.47 0.35 0.59 0.63 0.20 0.39 L 2.5 x 2.5 x 0.125 0.72 0.62 0.25 0.125 0.37 0.20 0.77 0.65 0.15 0.50 L 2.5 x 2.5 x 0.250 1.40 1.19 0.25 0.125 0.69 0.39 0.76 0.71 0.29 0.49 L 2.5 x 2.5 x 0.375 2.05 1.71 0.25 0.125 0.98 0.56 0.75 0.76 0.41 0.48 L 2.5 x 2.5 x 0.500 2.65 2.26 0.25 0.125 1.22 0.72 0.73 0.80 0.53 0.48 L 3 x 3 x 0.250 1.68 1.43 0.313 0.25 1.18 0.54 0.91 0.82 0.49 0.58 L 3 x 3 x 0.375 2.47 2.10 0.313 0.25 1.70 0.80 0.90 0.87 0.70 0.58 L 3 x 3 x 0.500 3.23 2.77 0.313 0.25 2.16 1.04 0.89 0.92 0.91 0.58 L 3 x 3 x 0.625 3.94 3.35 0.313 0.25 2.57 1.26 0.88 . 0.97 1.12 0.58 L 3.5 x 3.5 x 0.250 1.99 1.69 0.375 0.25 1.93 0.76 1.07 0.94 0.80 0.69 L 3.5 x 3.5 x 0.313 2.46 2.09 0.375 0.25 2.37 0.94 1.06 0.97 0.98 0.68 L 3.5 x 3.5 x 0.375 2.93 2.49 0.375 0.25 2.79 1.11 1.06 1.00 1.15 0.68 L 3.5 x 3.5 x 0.438 3.38 2.87 0.375 0.25 3.18 1.28 1.05 1.02 1.32 0.68 L 3.5 x 3.5 x 0.500 3.83 3.25 0.375 0.25 3.56 1.45 1.05 1.05 1.49 0.68 L 3.5 x 3.5 x 0.563 4.26 3.62 0.375 0.25 3.92 1.61 1.04 1.07 1.65 0.67 L 3.5 x 3.5 x 0.625 4.68 3.99 0.375 0.25 4.26 1.77 1.03 1.09 1.81 0.67 L 4 x 4 x 0.250 2.28 1.94 0.375 0.25 2.94 1.00 1.23 1.07 1.21 0.79 L 4 x 4 x 0.313 2.83 2.41 0.375 0.25 3.61 1.24 1.23 1.10 1.48 0.78 L 4 x 4 x 0.375 3.38 2.86 0.375 0.25 4.26 1.48 1.22 1.12 1.75 0.78 L 4 x 4 x 0.438 3.90 3.31 0.375 0.25 4.87 1.71 1.21 1.15 2.01 0.78 L 4 x 4 x 0.500 4.41 3.75 0.375 0.25 5.46 1.93 1.21 1.17 2.26 0.78 L 4 x 4 x 0.563 4.92 4.18 0.375 0.25 6.02 2.15 1.20 1.20 2.51 .0.77 L 4 x 4 x 0.625 5.42 4.61 0.375 0.25 6.56 2.36 1.19 1.22 2.76 0.77 L 4 x 4 x 0.688 5.92 5.03 0.375 0.25 7.08 2.57 1.19 1.24 3.00 0.77 L 4 x 4 x 0.750 6.40 5.44 0.375 0.25 7.57 2.77 1.18 1.26 3.25 0.77 L 5 x 5 x 0.375 4.28 3.60 0.5 0.375. 8.37 2.30 1.52 1.36 3.44 0.98 L 5 x 5 x 0.438 4.91 4.12 0.5 0.375 9.65 2.67 1.52 1.38 3.96 0.97 L 5 x 5 x 0.500 5.58 4.74 0.5 0.375 10.9 3.03 1.52 1.41 4.47 0.97 L 5 x 5 x 0.563 6.23 5.30 0.5 0.375 12.1 3.39 1.51 1.43 4.97 0.97 L 5 x 5 x 0.625 6.88 5.85 0.5 0.375 13.2 3.73 1.50 1.46 5.47 0.97 L 5 x 5 x 0.688 7.51 6.40 0.5 0.375 14.3 4.07 1.50 1.48 5.96 0.97 L 5 x 5 x 0.750 8.15 6.93 0.5 0.375 15.4 4.41 1.49 1.51 6.44 0.96 L 6 x 6 x 0.375 5.12 4.35 0.5 0.375 14.9 3.38 1.85 1.60 6.07 1.18 L 6 x 6 x 0.438 5.94 5.05 0.5 0.375 17.2 3.93 1.84 1.63 7.01 1.18 L 6 x 6 x 0.500 6.75 5.74 0.5 0.375 19.4 4.46 1.84 1.66 7.92 1.17 L 6 x 6 x 0.563 7.56 6.43 0.5 0.375 21.5 4.99 1.83 1.68 8.82 1.17 L 6 x 6 x 0.625 8.35 7.10 0.5 0.375 23.6 5.51 1.82 1.71 9.70 1.17 L 6 x 6 x0.688 9.14 7.77 0.5 0.375 25.7 6.02 1.82 1.73 10.6 1.17 L 6 x 6 x 0.750 9.91 8.43 0.5 0.375 27.6 6.52 1.81 1.76 11.4 1.16 L 8 x 8 x 0.500 9.14 7.77 0.625 0.375 47.7 8.16 2.48 2.15 19.5 1.58 L 8 x 8 x 0.750 13.5 11.5 0.625 0.375 68.9 12.0 2.45 2.26 28.2 1.57 L 8 x 8 x 1.00 17.7 15.0 0.625 0.375 88.1 15.6 2.42 2.35 36.5 1.56 January 2000 v1-19 TABLE 26 -PIPE (Cont.) The listed sizes are provided for the convenience of the designer; however, availability should be checked before making the final design selection. Additional sizes and shapes may be available from suppliers. Nominal Pipe Sched* Size No. Out- In- Wall side side Thick- Diam Diam ness Area Weight in. in. in. in.= lb/ft Section Properties I S r in.4 in.' in. 5 2.38 2.25 0.065 0.472 0.555 10 2.38 2.16 0.109 0.776 0.913 2 40 2.38 2.07 0.154 1.07 1.26 80 2.38 1.94 0.218 1.48 1.74 160 2.38 1.69 0.343 2.19 2.58 0.315 0.265 0.817 0.499 0.420 0.802 0.666 0.561 0.787 0.868 0.731 0.766 1.16 0.979 0.728 5 2.88 2.71 0.083 0.728 0.856 0.710 0.494 0.988 10 2.88 2.64 0.120 1.04 1.22 0.987 0.687 0.975 23 40 2.88 2.47 0.203 1.70 2.00 1.53 1.06 0.947 80 2.88 2.32 0.276 2.25 2.65 1.92 1.34 0.924 160 2.88 2.13 0.375 2.95 3.46 2.35 1.64 0.894 5 3.50 3.33 0.083 0.891 1.05 1.30 0.744 1.21 10 3.50 3.26 0.120 1.27 1.50 1.82 1.04 1.20 3 40 3.50 3.07 0.216 2.23 2.62 3.02 1.72 1.16 80 3.50 2.90 0.300 3.02 3.55 3.89 2.23 1.14 160 3.50 2.63 0.437 4.21 4.95 5.04 2.88 1.09 3; 5 4.00 3.83 0.083 1.02 1.20 1.96 0.980 1.39 10 4.00 3.76 0.120 1.46 1.72 2.76 1.38 1.37 40 4.00 3.55 0.226 2.68 3.15 4.79 2.39 1.34 80 4.00 3.36 0.318 3.68 4.33 6.28 3.14 1.31 4 5 4.50 4.33 0.083 1.15 1.35 2.81 1.25 1.56 10 4.50 4.26 0.120 1.65 1.94 3.96 1.76 1.55 40 4.50 4.03 0.237 3.17 3.73 7.23 3.21 1.51 80 4.50 3.83 0.337 4.41 5.18 9.61 4.27 1.48 120 4.50 3.63 0.437 5.59 6.56 11.7 5.18 1.44 160 4.50 3.44 0.531 6.62 7.79 13.3 5.90 1.42 5 5 5.56 5.35 0.109 1.88 2.20 6.96 2.50 1.92 10 5.56 5.30 0.134 2.29 2.69 8.43 3.03 1.92 40 5.56 5.05 0.258 4.30 5.06 15.2 5.45 1.88 80 5.56 4.81 0.375 6.11 7.19 20.7 7.43 1.84 120 5.56 4.56 0.500 7.95 9.35 25.7 9.25 1.80 160 5.56 4.31 0.625 9.70 11.4 30.0 10.8 1.76 5 6.63 6.41 0.109 2.23 2.62 11.8 3.57 2.35 10 6.63 6.36 0.134 2.73 3.21 14.4 4.35 2.30 6 40 6.63 6.07 0.280 5.58 6.56 28.1 8.50 2.25 Schedule numbers conform to 80 6.63 5.76 0.432 8.41 9.88 40.5 12.2 2.20 ANSI Standard for Wrought Iron 120 6.63 5.50 0.562 10.7 12.6 49.6 15.0 2.15 and Wrought Steel Pipe, B36.10 160 6.63 5.19 0.718 13.3 15.7 59.0 17.8 2.10 and B36.19. VI -32 January 2000 TABLE 27 -SQUARE TUBE (Cont.) The listed sizes are provided for the convenience of the designer; however, availability should be checked before making the final design selection. Additional sizes and shapes may be available from suppliers. Designation D SQ x t Wall Weight Area in. in. lb/ft in) Axis x -x, y -y 1x, ly Sx, Sy r„ ry J in.' in.' in. in.` 2 SQ x .1875 Wall 2 SQ x .250 Wall 1.60 1.36 0.75 0.75 0.74 1.12 2.06 1.75 0.91 0.91 0.72 1.34 2.5 SQ x .1875 Wall 2.04 1.73 1.56 1.24 0.95 2.32 2.5 SQ x .250 Wall 2.65 2.25 1.92 1.54 0.92 2.85 3 SQ x .1875 Wall 3 SQ x .250 Wall 3 SQ x .3125 Wall 2.48 3.23 3.95 2.11 2.75 3.36 2.79 3.49 4.10 1.86 2.33 2.73 1.15 1.13 1.10 4.17 5.20 6.07 3.5 SQ x .1875 Wall 3.5 SQ x .250 Wall 3.5 SQ x .3125 Wall 2.92 3.82 4.69 2.48 3.25 3.98 4.56 5.76 6.81 2.60 3.29 3.89 1.35 1.33 1.31 6.82 8.58 10.1 4 SQ x .1875 Wall 4 SQ x .250 Wall 4 SQ x .3125 Wall 4 SQ x .375 Wall 4 SQ x .500 Wall 3.36 4.41 5.42 6.39 8.23 2.86 3.75 4.61 5.44 7.00 6.94 8.83 10.5 12.0 14.6 3.47 4.41 5.26 6.02 7.29 1.56 1.53 1.51 1.49 1.44 10.4 13.2 15.7 17.9 21.4 5 SQ x .1875 Wall 5 SQ x .250 Wall 5 SQ x .3125 Wall 5 SQ x .375 Wall 5 SQ x .500 Wall 4.24 5.59 6.89 8.16 10.6 3.61 4.75 5.86 6.94 9.00 14.0 17.9 21.6 24.9 30.8 5.58 7.16 8.62 9.96 12.3 1.97 1.94 1.92 1.89 1.85 20.9 26.8 32.2 37.1 45.6 • 6 SQ x .1875 Wall 6 SQ x .250 Wall 6 SQ x .3125 Wall 6 SQ x .375 Wall 6 SQ x .500 Wall 5.13 6.76 8.36 9.92 12.9 4.36 5.75 7.11 8.44 11.0 24.6 31.7 38.4 44.7 55.9 8.19 10.6 12.8 14.9 18.6 2.37 2.35 2.33 2.30 2.25 36.8 47.5 57.5 66.7 83.2 VI -36 January 2000 4:39 PM 4/28/2008 Rupert Engineering, Inc. 1519 W. Valley Hwy N. Auburn, WA 98001 tel. (253) 833-7776 Project Westfield Sign Foundations Engineer. AEP Date: 28 -Apr Project# 08049 Subject 4x4x1/4thk Angle @ 45 deg. Checker. Date: Page: Units: in Nodes Coordinates 4) = X Y 1 0.000 0.000 2 2.828 2.828 3 2.902 2.652 4 2.828 2.475 5 0.619 0.265 6 0.509 0.000 7 0.619 -0.265 8 2.828 -2.475 9 2.902 -2.652 10 2.828 -2.828 11 0.000 0.000 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Engineer. as Section Properties About Centraidal Axis Parallel to Original Axis- . 4) = p.000_deg X -dim = 2.902 in A= 1.94 in^2) Y -dim= 5.656 in Xcg = 1.497 in Sx(top) = 1.6 in^3 Ycg = 0.000 in Sx(bot) = 1.6 in^3 Ixo = 4.6 in^4 Sy(Ieft) = 0.8 in^3 lyo = 1.2 in^4 Sy(right)= 0.9 in^3 Ixyo = 0.0 in^4 1 3 2 0 4 6 Sheet Section_by_nodes File: Structural section properties.xls Section Properties About Principal Axis___-_ 4) = ixp = Iyp = Ixyp = J = 0.000 deg 4.6 in^4 1.2 in^4 0.0 in^4 5.8 in^4 . Sxp(top) = Sxp(bot) = Syp(left) = Syp(right)= 1.6 in^3 ,> 1.6 in" 3', 0.8 inA3 0.9 in"3 1 3 2 0 4 6 Sheet Section_by_nodes File: Structural section properties.xls Type of Stress Type of Member or Component Sec. 3.4. Allowable Stress Tae - bl221 Allowable Stresses for BUILDING TENSION, axial Any tension member 1 19 :' '4117;:i • - .•., ,,„ .1. and Similar Type Structures 6061-T6, -T651, -T6510, -T6511 TENSION IN BEAMS, extreme fiber, net section Rectangular tubes, structural I -IIT ;" shapes bent around strong axis Round or oval tubes3 -0-0C) - Shapes bent about weak axis, --. bars, plates 2 4 19 24'13St- ..,,,,,.....,,, ' 1,11f :', ., , ' Extrusions up thru 1 In., Sheet & Plate, Pipe, Standard Structural Shapes, Drawn Tube, Rolled Rod and Bar, 6351-T5 Extruslons ,,. .„ „ WHITE BARS apply to nonwelded members and to welded 28 ,-- members at locations farther than 1.0 in. from a weld. - ' . ZSHADEDBARS.3: apply within 1.0 In. of a weld. BEARING On rivets and bolts On flat surfaces and pins and on bolts In slotted holes 5 6 39 26 ., ., ;;!42 -'.4, ' 1,6f ''' .. , ''i-,''' ' Equations that straddle the shaded and unshaded areas apply to both. *For tubes with circumferential welds, equations of Sections 3.4.10, 3.4.12, and 3.4.16.1 apply for Rbit s 20. Type of Stress Type of Member or Component Sec. 3.4. Allowable Stress Slenderness s S,Between Slenderness Lim1 n s Allowable Stress Slenderness S, and S2 Slenderness Limit S2 Allowable Stress Slenderness S 2 COMPRESSION IN COLUMNS, axial, gross section Allcolumns 7 - -,..-,...• kUr = 0 20.2 - 0.126 (klir) IcLir = 66 51,000/(kUr)2 • : .,-,--,--.7-4...--,i,-.Ynt,°: ,,,,,,.,i24,.;4,,34:-..4,.: •-'......si...:,.b,t:1,.1. ,:.,,4 .„..;:,,,.,,3,.74.:11,,,,..!,34-; ...:.' ).:it " ''','''''.' 1.”4'1,,,r"•,”,. .7 z..;,•C''.s.,`,:,,': ,.,',i;;:::,-. , .,12-,;ty.,,,,,,,,i7-,., i'W...,;,,--1:: ':,:,,::: .,!ku- LUr ...,.:. 65i:;,,i,.,ii:: ..''' ' 2 - 4,-,,,,-=---,4,-- ,-,---,--- • :i•:,,,,ii,,0,'•co(, kti`-ri!:,-,c;,,'. . .:';'.: : ':'. , '.° ' .`,'' ' " • '' ''' s' f:' COMPRESSION IN COMPONENTS OF COLUMNS gross section Flat plates supported along one - columns buckling about a -I- E-1-4 symmetry axis 8 21 bit = 2.7 23.1 - 0.79 (bit) bit = 10 1541(l'/:)edge ,,f .7 ,' i:1:2f:i'.', ',: : 1••• A if.•17-471:-c•;1' -'-.. ,-', - ;.;-.' ; •.•::-`;;:'''','-.',` ''',"'-' ;1,''',":"117-1!':-":'''''S•'''..':,f•r; '''.':•1"- --.' .11' ' '‘'.. • 1::- bit --,.- 13t .', ': - ' : : "B4/(b/t) Flat plates supported along one edge - columns not buckling about -L--1-1 1 8.1 21 -::1.,, , :,;','",11:ii-i.f ., ' ,4• : '!` . :1 bit = 2.7 .„,. ,..7:...,..,,,v..7;: 374,:, : 1 " „, ,.•,: .:. .. 1` •.. ''' * ' '• • • 23.1 - 0.79 (bit) -•:,,,.:- ,,,,,,::: 7 :z. i• ,,,,•°°,, °;°°° ,'.:„-° . ::,: 71:.- . ••°.'' " ' 1'!: = 12 737,707,-,,,*, r • -,,,,, nr., --•-•:.- • , • „ :.`. ' '.; .. bIt= 13f ''' ''' : 1970/(b/t)2 •••,-- -----.., n-^-,,,,,,- *.• ,rn ,r-- . „ ., , .. ' ; ' '`1970/0/02 ' ' ' • a symmetry axis Flat plates with both edges supported H n4-1,-.)„...._ 9 21 ,,,,,, 71;%74 ' ' ' I -..,...tif.,, „,, bit = 8.4 if.", ;,:',Ax te,147,ja a'...7.%i:::Tra'. ,, „ : ; 1 ,,,,4-1,;.-. -...:,-,:,,,,,,,', , • ,-.,,: ;,. • -.;;;:i.,,,?:......,,,v• . . -; 23.1 - 0.25 (b/t) , . 4'9.1. ."% "i'et,tr ie -. 3:.;,.1,,, :,: ,,,';','-'',•i; :„.; --,,,:it;• t-- 5•:::: bit = 33 r, ..:3_, e ' '-,; .''.:° .r,'".' .":' ,, •,--i, ,,,,:-,, i-',:- ...-. :•.-•,,,,,..,-,..., . - ; • •Ibit..- 41f ,t.- .-', ' 490/0/0 '1'''''.."`'..n"'"% `' , • ''',''''' - ,...:'..,-.::',:.,', ,-i.N,,,,,t , „!.r•: -,,2, ,- .:...-.;,..f.4901(bio-.---' ','•••;.`,:. Flat plates with one edge supported and other edge with E stiffener 9.1 See Section 3.4.9.1 Flat plates with both 9.2 See Section 3.4.9.2 edges supported and with T—N7C-7 an Intermediate stiffener Curved plates supported R, R Rb on both edges, wails of round or oval tubes 10* 21 kit= 2.2 22.2 - 0.80/7 kit = 141 3200 „,.77r5770,7, .7.--.77--.. -11 '!'14.1:77177f!Irri7-‘ 7,7-7--r-77-7r• -r-1..-!--n:tr 7,7.-,,,rf;T:t 777,—,,,,...,.." . ;::!' ,Ii2f:i( 1` . 2 ' ;..:7,,,,,...! i“ J '' , . ".;;;,k-li4'''ci, i :';'' 7.: •--" 's :7-:,i , 4...1>':-.7,fi:3•-tit-7-7` :'•:•:43'3,=...tj so Vkli :•=,., 7 ' 7'''...,-.• :;1.,,. 7, s,'..er,',,,.., ., , . ,', ,R .-•->i'iAi 29i1',..: '''', .:,- ,-., ,:; ,.... - t...... -,, c • ,, ':- ;',.; ,-,... (I? 1110(1 f 11V /35)2 000z ki nuer 6) Type of Stress Type of Member or Component Sec. 3 4 Allowable Stress Slenderness s S, • Slenderness Limit S , Allowable Stress Slenderness Between S, and S, Slenderness Limit S Allowable Stress Slenderness i S 7 COMPRESSION IN BEAMS, extreme fiber gross section Single web beams bent about _ strong axis _ - _ 11 21 L,/rY 23 23.9 0 124LbJr, Lit;79 87,000 ..i..{ 121 ' 1. ,3 -r1-.171-=',11 ?ii"°=�'sr-•sr�"'e. # Z ,.^ .{ t°°• 3.. {r a t ', I^t E SSt L l ry ( )2 R Re R,, Round or oval tubes - v T 12* 25 R jr 28 'k. '•^r'-"'° 39.3 - 2.70 Rb/r RI: 81 Same as �xsys Mr t4} ` 5' ' -. . -r ^! a»r �; r , a , , ` R 1f = lam* °' `s' f # 23.9 it 39' R 7 ° r F :R✓r 137> ' Section 3.4°10 Solid rectangular and r --11--- • 13-7,1,7=7,,,r.-, 28 d/t Lb/d = 13 40.5 - 0.93 d/t Lbid d/r Lb/d = 29 11,400 :• , ,,,----.,.,f7' : F € • , Mr--; , z round section beams - I -11 • {Itt 6{ll •it 3„i&t.s._ .. rl/t' ! =,26 • 4P 5 - 0 93/1(1 Lid r'3 ..... f �i;: ,: , t dtt Lid = 29 r {tf..,,•. �•b,,,.,r�, �.. dit L ld ( ) (b ) Rectangular tubes and �. box sections 14 21 LbSC/5 7 146 23.9 - 0.24 JLy ,./ 5 / LbSC/.5 /,J = 1700 24,000 121 f p ---,-,..-,,,,,,,;1,. ",? ; '} t t tr �' t .^v :1" F r -,-1,:-.. I, s 1 Z^t ,. , t "11 s r x Ly S., 5 IrJ-=2 0 (LbSr/•5 yd ) COMPRESSION IN COMPONENTS OF BEAMS, com onent (component under uniform compression), gross section b --it- -I i -b Flat plates supported on one edge I C �-r' 15 21 , -rr t t,:T._- i Zt bit 6.8 r4.f w� .,y y 27.3 - 0.93 bit ! rn 6 % s 121 bit 10 r'F' it 5 S 182/(b/t) T9K +C'<"` r 1 it,kkt) { -113/".-__.i T b f-- Flat plates with bothC /� edges supported ' �-/ 16 21 bit 22 27.3 0.29 bit bit 33 580/(b/t) 12 t , { . en §•r•'?.;:,. {. - t T(•rr 12 f ^m : b/t 8i , x 7•777`,74 Y>, 5$Sisi t) Curved plates supported Rb on both edgesr\--116.15�„g * 25 R,/t .6 26.2 - 0.94 Rb/r R,/r = 141 3800 ; ;��€ 7,1 14 r a` = :.: _. > {. ; ;Yr -.:4 S r .... 4:7 04 °R ft 1, t; r :RI/CF.::290 Rb/t 1 R yk /35 ( )( )z Flat plates with one edge supported and the other edge with stiffener --1 _1 16.2 See Section 3.4.16.2 Flat plates with both 16.3 See Section 3.4.16.3 edges supported and with an Intermediate stiffener m COMPRESSION IN COMPONENTS OF BEAMS, (component under bending in own plane) gross section Flat plates with compression edge free, - _ _1 b -f 17 28 , € ^ -� - a .• t6 , , e' ; bit=8.9 r t:', bit I7' ' , ,+ , , �s .. ,. _ . 40.5 1.41 bit # { a; r ' ,, 40 5 1X41;b/t bit 19 bit 19= 4 900/(b/r)2 _ s" , ".4;900/(b/tf tension edge supported Flat plate with both edges supported yh In 18 28 •,••...- s ,16 .,. hit 46 `9 e ^; ! Tri , ' r{ e- : , < :.. 40 5 0 27 Wt 9 s -: n _ .',...x t 16-t .• hit 75 .,- : - -r^-z h/t=95$ 1520/(Wt) a :1520/(Wt) Flat plate with horizontal c• d, stiffener, both edges hITIdi- supported I-'16 19 28 h/t 107 �w-�-, :! , `' ,. ; ; 40.5 0.117 hit hit 173 3500/(Wt) : r 4 - :'hi = 2i'9$ '3500J(h%t) , . . r 161 ` ; g ; tj . Y SHEAR IN WEBS, gross section 20 12 7i5�i�t , . hlt= 36 r -r . }~. 15.6 0.099 Wt IF % St... hit= 65 39,000/W02 Unstiffened flat webs I1 t h , 1 °h/1.7:724 �u' .. P 39,000/(hhl= Stiffened flat webs .a,-,1_,22__12 21 ..... 7:$t7.5t - 12 a /t =66 • a It =84# 53,000/(a./02 53 .., • . �/t)2 • ; - ae - at / Ji + 0.7(a1/a2) Geotechnical Report Westfield Shoppingtown Southcenter Expansion Tukwila, Washington At Shannon & Wilson, our mission is to be a progressive, well- managed professional consulting firm in the fields of engineering and applied earth sciences. Our goal is to perform our services with the highest degree of professionalism with due consideration to the best interests of the public, our clients, and our employees. September 15, 2005 Submitted To: Mr. Robert Gross, AIA Westfield Corporation 11601 Wilshire Boulevard, Suite 10 Los Angeles, California 90025 By. Shannon & Wilson, Inc. 400 N 34th Street, Suite 100 Seattle, Washington 98103 21-1-20189-004 SHANNON 6WILSON. INC stone columns is generally determined by the stone column contractor and is based on the required stone column diameter, improved soil strength and density, and drainage requirements. The stone columns should be constructed with open -graded, free -draining, crushed aggregate. We do not recommend the use of Geopiers to support the heavy colunm loads of the proposed garage and retail buildings because ofthe highly variable thickness of compressible soils and the resulting risk of differential settlements. 9.3.9 Lateral Pile Resistance Lateral resistance analyses were performed to assist the structural engineer in design of the foundation system. Two types of deep foundations were analyzed: 18 -inch -diameter, concrete -filled, steel pipe piles, and 20 -inch -diameter augercast concrete piles. Our analyses of lateral forces acting on the pile/shaft heads were performed using the commercial computer program LPILEpws 4.0 by Reese et al. (2002). This software generates discrete load -deflection (p -y) curves to estimate deflection of the pile/shaft and distribution of moments and shears along the length of the pile/shaft. Analyses were performed using two soil profiles: one below the garage located south of J.C. Penney (Area C) and the other for the garage located south of Sears (Area B). No efficiency (reduction) factors due to pile group action were used, but they can be estimated if necessary. Note that steel pipe piles and augercast piles for the mall retail expansion area would likely perform similarly to the garage piles. The results of our LPILE analyses are presented graphically in Figures 10 through 13. In summary, we expect that each of the piles analyzed would experience less than 1 inch of deflection under a lateral load of 40 kips applied at the top of the pile. Pile stiffness parameters assumed in our analyses are presented on Figures 10 through 13. 9.4 Spread Footings We understand that a single -story retail building could be constructed along the western boundary of the site, as shown on Figure 2. While preliminary structural engineering has not been done for this structure, we assume that it would have relatively low wall and column loads. The subsurface conditions at this location were explored with borings RB -6 and RB -7. The soils 21-1-20189-004-R1.doc/wp/EET 22 21-1-20189-004 SHANNON 6WILSON. INC. consist of medium dense sand from approximately 4 feet on down to 20 or 25 feet. Below 20 or 25 feet, the soils become dense to very dense. Thus, for a lightly loaded building, we recommend that spread footings be used for foundation support. Some loose soils could be present at the foundation excavation depth (2 to 3 feet); however, these soils could be compacted to a dense and unyielding condition that would provide adequate support for spread footings. We recommend that footings be designed for an allowable bearing pressure of 2,000 pounds per square foot (psf) at this location. The allowable value could be increased by one-third to account for wind and seismic loading conditions. We recommend a minimum embedment of 18 inches below the lowest adjacent grade (for frost protection). We also recommend a minimum footing width of 18 inches for continuous footings. All footing subgrades should be evaluated by a geotechnical engineer as the bearing surfaces are prepared. 95 Lateral Earth Pressures on Walls and Lateral Resistance for Wall Footings Lateral earth pressures will develop against buried portions of the buildings, service tunnels, and retaining walls. For below -grade walls, we recommend a static, active, lateral earth pressure corresponding to an equivalent fluid weight of 35 and 40 pounds per cubic foot (pcf) for compacted, imported structural fill and compacted on-site soil, respectively. These values are based on the assumption that proper drainage is provided against the back of the wall so that no buildup of hydrostatic pressure occurs and that a horizontal ground surface is behind the wall. Wall drainage should consist of a 1 -foot -thick (minimum) layer of clean drainage gravel placed against the wall and a perforated footing drain at the base of the wall. The total active earth pressure should be analyzed for seismic loading conditions using a dynamic load increment equal to 30 percent of the static, active earth force for both the imported fill and on-site soil cases. This percent load increment should be applied as a uniform Load to the wall, with the resultant force acting at the midpoint of the wall height. A 30 percent load increase for seismic conditions is consistent with a pseudo -static analysis using the Mononobe- Okabe equation for lateral earth pressures and a horizontal seismic coefficient of 0.13g. Values of the seismic coefficient are typically one-third to one-half the value of the PGA. For retaining walls founded on footings, lateral loads could be resisted by a combination of base friction and passive pressure against the footings and buried portions of walls. We recommend that the base sliding resistance for footings be determined based on an allowable coefficient of friction of 0.35 for on-site fill soil. We recommend an allowable passive pressure of 520 pcf and 21-1-20189-004-R1.doc/wp/EET • 23 21-1-20189-004 SHANNON 6WILSON, INC. 300 pcf for imported structural fill and on-site soil used as fill, respectively; both of these values are for soil above the groundwater table. If the buried portions of the walls are below the groundwater table, we recommend an allowable passive pressure of 250 pcf and 130 pcf for imported structural fill and on-site soil used as fill, respectively. Both the coefficient and passive pressure values above include an FS of 1.5. Retaining walls founded on piles would not develop base friction, but the pile stiffness and passive earth pressure would resist active earth pressures. 9.6 Slabs -on -grade Subgrade Recommendations We assume that the finished floor elevations would be approximately the same as existing grades at the site. Thus, floor slabs would be constructed over existing crushed surfacing or medium dense, sandy fill. For a rigid, concrete slab built on at least 2 feet of existing crushed surfacing that is compacted to a very dense condition, we recommend using a modulus of subgrade reaction, k, of 300 pounds per cubic foot (pci). A subgrade modulus of 200 pci could be used for slabs constructed over medium dense sand. All subgrades should be systematically compacted and evaluated for loose or soft zones. Loose or soft zones detected during the compaction process should be excavated and replaced with structural fill. We understand that up to 2 feet of fill would be added to raise the grade of the mall expansion area. If slab -on -grade floors are used, we anticipate that static settlements ranging from %2 to 1Y2 inches will occur due to the weight of the fill. If such settlement is unacceptable, lightweight fill, such as Expanded Polystyrene (EPS) blocks could be considered. The surface of the EPS should be sealed with a membrane to prevent petroleum contamination. EPS blocks dissolve upon contact with petroleum. Another consideration would be utility construction during and after placement. Slabs -on -grade could experience liquefaction -induced settlement, as discussed previously. The liquefaction -induced settlements during a 2,500 -year design earthquake could be as high as 10 inches. Differential settlements over a 20 -foot span could be about 50 to 75 percent of the total settlement. Ground improvement, such as stone columns, could be considered for mitigation of liquefaction -induced settlements. New and existing slabs -on -grade could behave differently during a design seismic event because of different support techniques, e.g., pile support for the existing shell structure versus slab -on - grade for the new structure. It should also be noted that buried utilities in areas that will receive additional fill to raise the grades should be designed to accommodate widespread settlements of up to 1Y2 inches, particularly near foundation element transitions, i.e., grade beams. 21-1-20184-004-RI.doclwpIEET 24 21-1-20189-004 STRUCTURAL NOTES 00320 GEOTECHNICAL DATA The foundation design is based on the recommendations in report No. 21-1-20189-004 by Shannon & Wilson, Inc. dated September 15, 2005. Unless otherwise indicated foundation work shall be performed in accordance with this geotechnical report. The geotechnical report is part of the project contract documents and should be kept on the job site at all times. 00700 GENERAL CONDITIONS All materials and construction shall conform to the drawings, these notes, and any specifications for this project. During the construction period, the Contractor shall be responsible for the safety of the construction project, including all excavation procedures. The Contactor shall provide adequate lagging, shoring, bracing, guys and protection of adjacent property, structures, streets, and utilities in accordance with all national, state, and local safety ordinances. All information shown on the drawings relative to existing conditions is given as the best present knowledge, but without guarantee of accuracy. Where actual conditions conflict with the drawings they shall be reported to tete Engineer so that the proper revisions may be made. Modification of design drawing details shall net be ma.de without written approval of the Engineer. Provide vertical support and lateral bracing for electrical and mechanical equipment per the applicable code requirements. DMSION 1- GENERAL. RE Ui EEtIC��(TS 01412 BUILDING CODES International Building Code (IBC) 2006 Edition. Washington State Building Code (Washington Administrative Code (WAC) Chapter 51-30) 01415 DESIGN LOADS AND CRITERIA WIND: Basic Wind Speed: 85 mph Exposure: C Importance Factor (IW): 0.87 FOUNDATION: Allowable Soil Bearing Capacity (DL -ELI): Soil Passive Pressure: 2,000 PSF 300 PCF 01455 TESTING AND INSPECTION All special inspection and testing shall comply with IBC Sections 1701, 1703, 1704, and other applicable building code sections and are in addition to the inspections made by the Building Official under Section 109. Special inspections are required for the following work: Earthwork: During excavation, grading, and filling Construction of drilled piles or caissons Concrete: Placement of reinforcing steel, concrete placement and taking of concrete cylinders, where inspection is required by Section 03300 Placement of anchor bolts, where noted on plans Installation of adhesive anchors Field Welding: Reinforcing steel Structural and miscellaneous steel Installation of high-strength bolts Special inspectors and testing laboratories shall be PROVIDED BY THE OWNER. The Contractor shall coordinate special inspections as well as standard building inspections with the construction schedule and is responsible for facilitating access to areas to be inspected. Special inspectors and testing laboratories shall be approved by the Building Official, and shall be certified by the Washington Association of Building Officials (WABO), if required by the Building Official. The special inspector shall observe the work for conformance with the design drawings and specifications. The special inspector shall fumish inspection reports to the Building Official and the Engineer. All discrepancies shall be brought to the immediate attention of the Contractor for correction, and also to the Building Official and the Engineer. The special inspector shall submit a final signed report stating whether the inspected wok was in conformance with the design drawings and specifications and the applicable provisions of the building. code. Special inspections per IBC Section 1703.7 are required unless fabricator is approved per Section 1704.2.. DIVISION 2 - SITEWORK 02315 EXCAVATION AND FILL All footings shall bear on undisturbed ground or structural fill and shall be a minimum of 18 inches below grade unless noted otherwise on the drawings. Foundation excavations shall be examined and approved by the Engineer — or a testing laboratory approved by the owner — and the Building Official prior to the placement of any reinforcing steel or concrete. Material for filling and backfilling shall consist of the excavated material and/or imported borrow and shall be free of organic material, construction debris, cobbles, or other debris. Fill and backfill shall be deposited in layers not to exceed 8 inches thick for heavy equipment and 4" thick for hand operated equipment The fill shall be properly moistened to approximate optimum requirements and thoroughly rolled or compacted with approved equipment in such a manner and extent as to produce a relative compaction of 95% of maximum dry density for optimum moisture content as determined by ASTM D 1557. Each lift shall be tested for compliance with compaction requirements by an approved laboratory. See Section 01455. Hand tampers shall weigh at least 50 lbs. each and shall have a face area not in excess of 64 square inches. Hand tamper may be operated either manually or mechanically and shall be used only where larger power driven compaction equipment cannot be used. DIVISION 3 - CONCRETE 03152 ANCHOR BOLTS Materials, fabrication and erection shall conform to IBC Chapter 22, IBC Standard Section 2204, and the AISC 360-05 Specification for Structural Steel Buildings. Galvanize threaded parts, bolts, nuts, and washers exposed to weather unless noted otherwise per ASTM A 153. Material specifications, unless noted otherwise: Anchor Bolts: ASTM A 307 Threaded rod: ASTM A 36 High -Strength Bolts: ASTM A 325, where noted Nuts: ASTM A 563 Washers: ASTM F 436 Substitution of other materials requires approval of the Engineer. Provide anchor bolt configuration as shown including diameter, spacing, projection, embedment, and end configuration. Substitution of another type of anchor requires approval of the Engineer. 03210 REINFORCING STEEL Concrete reinforcing steel shall be deformed bars conforming to ASTM A 615, Grade 60 (or A 615M -96a, Grade 420), made from new billets. Reinforcing to be welded shall be Grade 60 (Grade 420) with a Carbon Equivalent (CE) of 0.55 or less, or ASTM A 706 (or A 706M -96b). Do not use epoxy -coated reinforcing unless noted. Bars marked with metric sizes as shown below conforming to the metric specifications and grades shown above may be substituted for the bars shown on the drawings. Bar spacing, embedment and lap lengths, reinforcing cover, bends, and hooks remain the same. Fabrication and placement of reinforcing in concrete shall conform to IBC section 1907. Lap all reinforcing bars at all splices, comers, and intersecting walls per table below (unless noted otherwise): #3 (#10) #4 (#13) #5 (#16) #6 (#19) #7 (#22) #8 (#25) #9 (#29) Concrete Strength (PSI) 2,000 3,000 Top Other Top Other 27 21 22 17 35 27 29 22 44 34 36 28 53 41 43 33 77 59 63 48 87 67 72 55 98 76 81 62 4,000 Top Other 19 15 25 19 31 24 37 29 55 42 63 48 71 54 5,000 Top Other 17 13 22 17 28 22 34 26 49 38 56 43 63 49 6,000 Top Other 15 12 20 16 25 20 31 24 45 34 55 43 57 44 Use "TOP" reinforcing values for horizontal bars with more than 12" of concrete below them in the casting position. Lap lengths (in inches) are based on normal weight concrete (in PSI) and a minimum 2 db spacing and 1 db cover (per ACI 318-05). The sizes shown (#xx) are the corresponding metric bar sizes. Minimum cover over reinforcement, unless noted otherwise: Concrete placed on earth: Concrete exposed to earth or weather. Other conditions (UNO): 3 inches 2 inches 1-1/2 inches Reinforcing steel welding shall be performed by WABO certified welders and shall conform to IBC Sections 1901.2 and 1903.5.2 (AWS Welding Code D1.4-98 with modifications). Reinforcing shall be securely tied in position prior to concrete placement. Reinforcing shall be supported on chairs or slab bolsters (with distribution plates if required) or concrete dobies prior to concrete placement. Support spacing shall not exceed 10 feet in each direction. 03300 CAST -IN-PLACE CONCRETE All cast -in-place concrete shall meet the following requirements: Quality of concrete shall be determined by IBC Section 19. Minimum 28 day compressive strength shall be 2,500 PSI unless noted otherwise on the drawings or these notes. Use 5-1/2 94 LB sacks per yard of Type 1 cement with 6.6 gallons of water per sack of cement or submit mix design to the Engineer for review. See Section 01330. Slump shall be 4 inches • plus or minus 1 inch. Use Type I -A cement where air entrainment is required. All methods and materials per IBC Chapter 19. Water -reducing admixtures conforming to ASTM C 150 may be incorporated in the concrete design mixes and be used in strict accordance with the manufacturer's recommendations, subject to Engineer's approval. An air -entraining agent conforming to ASTM C 150 shall be used in alt concrete mixes for slabs and other flatwork to be exposed to weather. The amount of entrained air shall be 5% plus or minus 1% by volume. One percent maximum calcium chloride or other water-soluble chloride ion admixtures conforming to ASTM C 1218/C may be used in concrete not exposed to the weather or in unreinforced concrete. Other types of accelerating admixtures may also be used. All admixtures shall conform to ASTM C 618 Type C or F. Special inspection and testing is required for all reinforced concrete except for foundation concrete with a designated compressive strength not exceeding 2500 PSI and nonstructural slabs on grade. For each class of concrete where testing is required, the special inspector shall take not less than one set of three cylinders for each day of concrete placement, or for each pour, or not less than one set for each 150 cubic yards of concrete, or not fess than one set for each 5,000 square feet of surface area for slabs or walls. Anchor bolts, dowels, and other embedded items shall be securely tied in position prior to concrete placement. Do not add water at site. Maximum drop during placement is three feet Consolidate concrete with a mechanical vibrator as required. All exposed surfaces shall receive a steel trowel finish unless noted otherwise. Do not dust surfaces with dry cement to remove water. Concrete shall be maintained in a moist condition for a minimum of five days after placement or sealed with a curing compound applied in two coats at right angles. Follow manufacturer's application instructions and do not exceed recommended coverage. Keyed construction joints shall be used in all cases except slabs on grade. All construction joints shall be thoroughly cleaned and all laitance shall be removed. All vertical joints shall be thoroughly wetted and slushed with a coat of neat cement immediately before placing new concrete. Pipes other than electrical conduits shall not be embedded in structural concrete except where specifically approved. Do not embed aluminum conduits and sleeves in concrete. 03605 NON -SHRINK GROUT Non -shrink grout shall have a minimum compressive strength of 5,000 PSI. Use non- metallic type in exposed conditions. Install per manufacturer's recommended procedure. DIVISION 5 - METALS 05120 STRUCTURAL STEEL Materials, fabrication and erection of structural steel shall conform to IBC Chapter 22 and the AISC 360-05 Specification for Structural Steel Buildings. Paint all structural steel exposed to weather unless noted otherwise on drawings. Material specifications, unless Structural shapes: Bars and plates: Pipe: Structural tubing/HSS: Bolts: High -Strength Bolts: Nuts: Washers: Filler metal: noted otherwise: ASTM A 36 ASTM A 36 ASTM A 500, ASTM A 500, ASTM A 307 ASTM A 325, ASTM A 563 ASTM F 436 E70XX Grade B, Standard Weight Grade B where noted Substitution of other materials requires approval of the Engineer. Galvanizing of structural shapes and fabricated parts shall be done in accordance with ASTM A 123, after fabrication. Galvanizing of threaded parts, bolts, nuts, and washers shall be done in accordance with ASTM A 153. Welding shall be performed only by WABO certified welders and shall conform to AWS D1.1 and AISC specifications. E70T-4 weld material is not permitted. Minimum fillet weld size shall be 3/16" unless noted otherwise. Feld welds shall have special inspection per IBC section 1704.3.1. Reinforcing steel welding to structural steel shall conform to IBC Standard 19-1 (AWS Welding Code D1.4-98 with modifications). Provide 3/4" diameter air relief holes @ 12" OC each way in the horizontal surfaces of all embedded bearing plates and angles over 6" in width, when they are above the bottom of the concrete member in the casting position. ip®r1I .ng.rinig®Ttirrigo [In@E, CONSULTING ENGINEERS/CIVIL AND STRUCTURAL STRUCTURAL DESIGN CALCULATIONS OF WES'1'>i'EELD SIGN FOUNDATION 633 Southceuter Boulevard Tukwila, WA 98188 FOR PLUMB SIGNS 909 South 28th Street Tacoma, WA 98409 REI Job No. 08049 April 2008 1519 West Valley Highway North/Suite 101 Post Office Box 836/Auburn, WA 98071 253-833-7776 Fax 253-939-2168 10'-2" 10' 8' PROVIDE SUPPORT FOR FRONT AND REAR ACRYLIC PANELS 2'-7" MIN • -.1 d�- �+l.I� —1•F- •a-ly• . -{-1 �—_ -I :-F +- •:...r. +-=" -•-4. 1 1-.•:4 =F- ani 1--1 } — 2 1 •-----1.-- - '-1- - °I 1 14 -' ` I _ a 1 1- A - _ -LI � 8 8 6QI - - 4 - 4 1 ° - 14 a . d . 1 - .1 4_ • 1 • _ I- a I -1 41 1 1 .1 - 1 I-' - - a .I.r -L.L A : J- a I- - I-- a_ -.J .-..el' h •I 1 _I - - 11;1: - 4 I {_& 5 4 • Al la:. 1 r Ila lfa�'11 1} I L 4 .•a 11 1 • I- { < -t 1 •141v - i - f 11-e. 11 e'' - 1 I 11 ."94.-r - d -41 e _ 1 -- 1. 1 1. 1 1 4. f-11 a . al 4 - 4,1" _° 1 1 4 -I. .. I" 9 J 1 .1 4 - I -I i? - - - .1 r. l - J. ' fi " 4 1 ...,1- • la . 1 I - - •- 1' I l a I.° `1-11. -- '4 1]e•1•I- ' 1- _. 4. -.141•:11'4- :1- I -.l - 1 .. L I. ° 1 1 a• • - 4 114 31 a F �- -1 a1 i 1 : r4 • • 1 -I • 1.1 ° - U tJ • _ 1J - '1 -LI ' L.. - LJ- : prl• a -ds y 1'-` LJ LJ - - LI L1 _ t I -i LJ_ ° a SIGN, BY OTHERS THIS SIGN FOUNDATION ANALYSIS IS BASED ON SOIL BEARING PRESSURES TAKEN FROM THE RECOMMENDATIONS MADE IN GEOTECHNICAL REPORT #21-1-20189-004 PREPARED BY SHANNON & WILSON ON 10/27/05. IF SITE CONDITIONS DIFFER FROM THESE ASSUMPTIONS, THE ENGINEER MUST BE NOTIFIED SO THAT THE ANALYSIS MAY BE UPDATED TO MEET ACTUAL SITE CONDITIONS. 2'-0' I 11' 6" 3" EaR 3" CLR APPLY EPDXY PAINT TO ALUMINUM TUBES TO PREVENT CORROSIVE INTERACTION BETWEEN ALUMINUM AND CONCRETE. CAP BOTTOM OF TUBE AND APPLY PAINT OR PAINT TUBE INSIDE AND OUTSIDE. (TYP) - 6 e - d a- ( Y 0 - - a -044 e; -a -e- < 0 as a ` - oA _4o --- o • :°• „-.41- e SF's ate -..,per: - •d a- .4 a- - - 'a (8) 2.50 OD x 0.500 WALL 6061—T6 ALUMINUM TUBES a d a A 1 (9) 2.00 OD x 0.438 WALL 6061—T6 ALUMINUM TUBES RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 PROJECT NAME: WESTFIELD SIGN FOUNDATION, SIGN AA1 633 Southcenter Boulevard, Tukwila, WA 98188 SCOPE OF WORK: Determine the column and footing requirements for the sign subject to static wind loading per the 2006 International Building Code and ASCE 7-05. All sign material and connections to column by others. DESIGN CRITERIA: Basic Wind Speed: V = 85 MPH ASCE 7-05 FIGURE 6-1 Exposure Category: C ASCE 7-05 Section 6.5.6.3 Wind Importance Factor. Iw = 0.87 ASCE 7-05•TABLE 6-1 Total Height of Sign: 10.17 FT Nominal Height of Atmospheric Boundary layer. zg = 900 -FT ASCE 7-05 TABLE 6-2 Power Law Exponent a = 9.5 ASCE 7-05 TABLE 6-2 Exposure Constant ;in = 15 FT ASCE 7-05 TABLE 6-2 Turbulence Factor c = 0.2 ASCE 7-05 TABLE 6-2 Integral Length Scale Factor. C = 500 FT ASCE 7-05 TABLE 6-2 Integral Length Scale Exponent Eave = 0.20 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Exponent aam = 0.15 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Factor. bay = 0.65 ASCE 7-02 TABLE 6-2 Period Coefficient Cr = 0.02 ASCE 7-05 Table 12.8-2 Period Coefficient x = 0/5 ASCE 7-05 Table 12.8-2 Approximate Fundamental Period: Ta = 0.11 SEC ASCE 7-05 Eqn. 12.8-7 DESIGN LOADS: Top Sign: Height 10.17 FT Width: 10.67 FT Point of Wind Load Application: 6.11 FT Sign Area: AphP = 27.74 FT2 Velocity Pressure: qh = 0.00256KhKZiKdV2Iw Exposure Coefficient: Kh = 0.85 ASCE 7-05 TABLE 6-3, NOTE 2 Kt = 1.0 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 Ka = 0.85 ASCE 7-05 TABLE 6-4 qh = 11.6 LB/FT2 Gust Factor G = 0.925(1+1.7gatzQ)/(1+1.7g„ IZ) Intensity of Turbulence: IZ = 0.228 go = 3.40 ASCE 7-05 Section 6.5.8.1 g„ = 3.40 ASCE 7-05 Section 6.5.8.1 Equivalent height of structure: z. = 15.0 ASCE 7-05 Section 6.5.8.1 Background Response: Q = 0.956 LZavo = 427.1 Rigid Gust Factor. G = 0.902 Clearance Ratio: Heighte /Height,,,rai = 1.000 ASCE 7-05 Figure 6-20 Aspect Ratio: WidtNigr,/Heightsig„= 1.049 ASCE 7-05 Figure 6-20 Net Force Coefficient: Cr = 1.57 ASCE 7-05 Figure 6-22 Design Wind Force: F = gi,GC Ar = 456.1 LB Overturning Moment 3018 LB -FT ASCE 7-05 Figure 6-20 Job No. 08049 5/112008 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Auburn, WA 98001 Bottom Sign: Height: 10.17 FT Width: 10.67 FT Point of Wind Load Application: 3.81 FT Height of Top of Sign Above Grade: 10.17 FT Af-bottom = 31.24 FT` Velocity Pressure: qh = 0.00256KhKZjKdV21W Exposure Coefficient Kh = 0.849 ASCE 7-05 TABLE 6-3, NOTE 2 Kr' = 1 ASCE 7-05 SECTION 6.5.7.2 & FIGURE 6-4 Ka = 0.85 ASCE 7-05 TABLE 6-4 qh ' 11.6 LB/FT` Gust Factor. G = 0.925(1+1.7g0IZQ)1(1+1.7g„I=) Intensity of Turbulence: lz = 0.228 go = 3.40 ASCE 7-05 Section 6.5.8.1 g„ = 3.40 ASCE 7-05 Section 6.5.8.1 structure: za,re = 15 ASCE 7-05 Section 6.5.8.1 Background Response: Q = 0.958 Lz ave = 427.1 Rigid Gust Factor G = 0.903 Clearance Ratio: Heightty„/Heighttom = 1.000 ASCE 7-05 Figure 6-20 Aspect Ratio: Width „/Heightaar,= 1.049 ASCE 7-05 Figure 6-20 Net Force Coefficient: Cf = 1.57 ASCE 7-05 Figure 6-20 Design Wind Force: F = qhGCtAr= 514.1 LB Overturning Moment 2220 LB -FT ASCE 7-05 Figure 6-20 TOTAL OVERTURNING MOMENT: TOTAL WIND FORCE HEIGHT OF RESULTANT FORCE FOUNDATION DESIGN: 5239 LB -FT 970 LB 5.40 FT Lateral Bearing Pressure: 300 PSF/FT IBC TABLE 1804.2 Constrained Depth of Footing: Combined Footing? Yes or No? CONSTRAINED: d2 = 425[My/(S3b)) Combined Footing? Yes Shape of Footing: Rectangular Length: 11.50 FT Long Dimension Parallel with Sign Width: 2.00 FT b= 11.67 FT Allowable Lateral Pressure: S1= 254.0 PSF S3 = 762.0 PSF A = 2.34`F/(S1'b) = A = 0.77 Nonconstrained Depth of Footing: d = 2.54 FT Job No. 08049 5/1/2008 • napFlua@mtnig, CONSULTING ENGINEERS/CIVILAND STRUCTURAL 1519 West Valley Highway North/Suite 101/Auburn, WA 98001 Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB coo/-! q - 11i TFi 1 L b 5'1 -quivincTl rias SHEET NO OF �Q AE DATE CALCULATED BY CHECKED BY DATE SCALE 3icv __ ALw': 1-7 �- 760E-'3AU-C > • (1)20 : AuLoR -1.�BF antics (3) 2„ :. ALL., _�rcrvW,-1 &r=5 DEs19Q L-rocipz > N4 =(04%KFT-) = 0.7314 K, r F 13_�KSN(3� _S,�K.Sc C1u tR Fri cz7 UMW—US— M _ D.73�> - Fr %.©k51 0,461 Ns 5-0 06ND s= 3(0.537) = iw3 .2,52. iti' 0,4tq i,v 3 Q - iri 7 s1Y1) 3c1okl N61,us 7— ®,2SWAIL- S = AtLS._ %(0.53'7 --(40,Mo6)i _'11,0IN3 -� = (5 2 5.71 itz it 0 (nt4PR.EioM: 1/2.5 , 5 £ 4q mos F- ii( : ` 18,711 (>s.7z, 63.s ,, D PRODUCT 207 Na-jolgTg -Rg[Inig®A J go 'CONSULTING ENGINEERS/CIVIL AND STRUCTURAL STRUCTURAL DESIGN CALCULATIONS OF WES'1 k FELD SIGN FOUNDATION 633 Southceuter Boulevard Tukwila, WA 98188 FOR PLUMB SIGNS 909 South 28th Street Tacoma, WA 98409 REI Job No. 08049 April 2008 iv7- 1519 West Valley Highway North/Suite 101 Post Office Box 836/Auburn, WA 98071 253-833-7776 Fax 253-939-2168 8'-2' #4's 8' 81" [1 PIPES STUBBED 1Y2" INTO CABINET AND WELDED TO CAPS AT TOP AND BOTTOM OF CABINET FRAME (TYP) SIGN, BY OTHERS 2'-3' MIN 4 6 . -,•I 4-4 =4 :4i- -=11'. - 4..4. 4--_h'- -6-I-1 -4- —1.1- e ! -1.-4.2i- ----144- —4:1-"..12- IS' --I1ar9 a < -41 - I.1- I -- - - -1. .V- 4 - .u - a J 1_ •1 . . :1 I- I 1 - _f 1-- - n -1 .41 :(. e - I I J 4. • 1-.1 _ - 1 .A -I 'a' 4 F. I_ . I° _ i- -1 I I 1 4- 1 L • L•i 61 f I• a- I- 141. - -r - r al - 1 .a 1 1. 1 11_ '- 11 P1• •¢1 •/ •.1 • a1-1 - -I -. 1-- I-- •j -r` -- , I-4. r_1a8-1 -- -r-d e 1{ -la_- •. 11_ _ 1 - ' I. 1i 14 I I- I •-I.4 LJ 'L1.a_ h_I Lala _a LJe u aU i1 -• 1__I LJa _LI-- • L •U .e 9' 6" THIS SIGN FOUNDATION ANALYSIS IS BASED ON SOIL BEARING PRESSURES TAKEN FROM THE RECOMMENDATIONS MADE IN GEOTECHNICAL REPORT #21-1-20189-004 PREPARED BY SHANNON & WILSON ON 10/27/05. IF SITE CONDITIONS DIFFER FROM THESE ASSUMPTIONS, THE ENGINEER MUST BE NOTIFIED SO THAT THE ANALYSIS MAY BE UPDATED TO MEET ACTUAL SITE CONDITIONS. #4's CLR 3" CLR F APPLY EPDXY PAINT TO ALUMINUM TUBES TO PREVENT CORROSIVE INTERACTION BETWEEN ALUMINUM AND CONCRETE. CAP BOTTOM OF TUBE AND APPLY PAINT OR PAINT TUBE INSIDE AND OUTSIDE. (TYP 2'-0' 4 9 4 a 4 - a - 1'-84 (7) 2.50 OD x 0.250 WAIL 6061—T6 ALUMINUM TUBES (7) 2.00 OD x 0.250 WALL 6061—T6 ALUMINUM TUBES RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Aubum, WA 98001 PROJECT NAME: WESTFIELD SIGN FOUNDATION, SIGN AA2 633 Southcenter Boulevard, Tukwila, WA 98188 SCOPE OF WORK: Determine the column and footing requirements for the sign subject to static wind loadingper the 2006 International Building Code and ASCE 7-05. All sign material and connections to column by others. DESIGN CRITERIA: Basic Wind Speed: V = 85 MPH ASCE 7-05 FIGURE 6-1 Exposure Category C ASCE 7-05 Section 6.5.6.3 Wind Importance Factor: Ix, = 0.87 ASCE 7-05 TABLE 6-1 Total Height of Sign: 8.17 FT Nominal Height of Atmospheric Boundary layer zg = 900 FT ASCE 7-05 TABLE 6-2 Power Law Exponent a = 9.5 ASCE 7-05 TABLE 6-2 Exposure Constant ;lin = 15 FT ASCE 7-05 TABLE 6-2 Turbulence Factor c = 02 ASCE 7-05 TABLE 6-2 Integral Length Scale Factor. e = 500 FT ASCE 7-05 TABLE 6-2 Integral Length Scale Exponent Ea,,,, = 0.20 ASCE 7-05 TABLE 6-2 Mean Hourly Wmd Exponent aa,,e = 0.15 ASCE 7-05 TABLE 6-2 Mean Hourly Wind Factor b. = 0.65 ASCE 7-02 TABLE 6-2 Period Coefficient C, = 0.02 ASCE 7-05 Table 128-2 Period Coefficient x = 0.75 ASCE 7-05 Table 12.8-2 Approximate Fundamental Period: TB = 0.10 SEC ASCE 7-05 Eqn_ 12.8-7 DESIGN LOADS: Top Sign: Height: 8.17 FT Width: 8.69 FT Point of Wind Load Application: 3.99 FT Sign Area: Ar,,op = 37.86 Ff2 Velocity Pressure: qh = 0.002561cicil .V21N, Exposure Coefficient: Kh = 0.85 ASCE 7-05 TABLE 6-3, NOTE 2 Ki = 1.0 ASCE 7-05 SECTION 6.57.2 & FIGURE 6-4 Ka = 0.85 ASCE 7-05 TABLE 6-4 qn = 11.6 LB/FT2 Gust Factor G = 0.925(1+1.7gn1=Q)/(1+1.7g„I2) Intensity of Turbulence: iz = 0.228 go = 3.40 ASCE 7-05 Section 6.5.8.1 gy = 3.40 ASCE 7-05 Section 6.5.8.1 Equivalent height of structure: z. = 15.0 ASCE 7-05 Section 6.5.8.1 Background Response: Q = 0.961 L=am = 427.1 Rigid Gust Factor. G = 0.905 Clearance Ratio: Heightag„/Heighth„iz, = 1.000 ASCE 7-05 Figure 6-20 Aspect Ratio: Widthsg„/Heightsg„ = 1.064 ASCE 7-05 Figure 6-20 Net Force Coefficient: Cr = 1.57 ASCE 7-05 Figure 6-22 Design Wind Force: F = q,,GCF1r = 624.3 LB Overturning Moment 2746 LB -FT ASCE 7-05 Figure 6-20 HEIGHT OF RESULTANT FORCE 4.40 FT Job No. 08049 4/29/2008 RUPERT ENGINEERING, INC. 1519 West Valley Highway North, Aubum, WA 98001 FOUNDATION DESIGN: Lateral Beating Pressure: Constrained Depth of Footing: CONSTRAINED: Combined Footing? Shape of Footing: Length: Width: b= Allowable Lateral Pressure: S1= S3= A = 2.34*F/(S11b) = A = Nonconstrained Depth of Footing: d = 300 PSF/FT IBG TABLE 18042 Combined Footing? Yes or No? d2 = 425[IVl1(S b)] Yes Rectangular 9.50 FT 2.00 FT 9.71 FT 219.1 PSF 6572 PSF 0.69 2.19 FT (4. Long Dimension Parallel with Sign Job No. 08049 4/29(2008 Gad jx E cocgifluDe@n u jo 0160 CONSULTING ENGINEERS/CIVIL AND S 1 HUCTURAL 1519 West Valley Highway North/Suite 101/Aubum, WA 98001 Post Office Box 836/Auburn,WA 98071 253-833-7776 Fax 253-939-2168 JOB OFtAct Srcr b bkna\ SHEET NO CALCULATED BY CHECKED BY SCALE AFV OF DATE DATE 31 AA. Ami : eoCrz'! 76 , rs : (2i/�7< ALLLM J Cth-1l ti -BES A Lxv,iIrcwvl 5Es lrd Ls rAos M= 2.74& k - -r V=4,l&24K I==13.5ksr:(3) -15.Oka1 %URE.t �sc To . Mo,iLL-LLS T�r %urn*. WAu_. (. 2:00 oD x Ow.— . x 0.250 WALI.— M 2, 7,46 g• Fr (12. r 140 irzt 5 - :a5B74,)} 06/06(0 = a43 - � 8 65 ru3 _ £.746k•Pr624r).. Ks/ 8, G5 1Ai3 compFzEsicshal -1 2.5t,�2� I� (`' R D.�S ►Aa r 35 .o ►�--� (12 r .!� /.63(AS5 a. OK. 18,7,<s t � e 4Ll7�, D PRODUCT207 _ „.„„ 1 ...... /, Pry L_E .. .. .._.._.._V- , . _ •RING RING ROAD • • . � -•L ROAD ' : PROPERTY UNE — 40-t tg i II - , z, EA II 4 ,_.__, 1 0 fililp PROPERTY UNE In ' t SIGN - AD1 L - = i SIGN - AD1 SIGN - AA2 0 14 m 15 a JCPENNEY t ° N y{J{tfi 27-r ! a IMI I% I I PLANTER PER - �� ♦ I • ,�, '—� ' w♦ I "�r�' MEN 1 �y a STOP p•9`�r• ��e'= * li _ I� rn.•a � _ ' / / RING ROAD . ,'�Iti'I'r - = i - Ad.. - I• _ (�` ....,;;;,-?;;till-, R-� 4114:1 .• • Q ARKING "A".I -1 �•� �_ P RKING STRUCTURE "B;; km ' JJI 3c.Q .e �4•'•�F.i6 [ ,r I't' „1'I � '1110. iI'jI VW SIGN - AD1 SIGN - AA1 SIGN - AD1 ' " 11 SIG 1 -' ' 91 9 O 10 12 FIRESTONE I I II L I=ri ° .i ►� / a FIRESTONE � s NE 16 {0'3.//: �� PLANTER '. �• ,y IIIIIIIIII•-6• I I - i ' DRAMNG l� = ��: _ �•.,i,.uuudznz, w... d:limi \ NO m _ ou o4:�� r mi / A mi`,.6°t° PLANTER PER LDRAWINGANDSCAPE '�,. I I g. to �O�: � • I E. STOP ..o .o ,,: - _T =OM MI :: : b o iF ii a Q !!• .y111I't„0+�ocoo� ;'.' O 1:. ' ed "_MI PARKING _AA �,;� ►II, e of TRUCTURE "A” 3! .coo.Co U I \- 1 • •I '�it C/coo. V / 'c� I ----I L-:• "6 © O O O e.\ ' 56 - I I 1 I 0�� �: o. o �e4 -aa,, E. LitNDSCAPE / \ / \ 1 \ I I r •� G,f �. SCAPE DRAWN 'fad,+"�: 1.1' '.1 t !•.:.i. �:_)♦'.;�% QFNFRAI NOTE. 4 ; ::. w �. i �� � 1q. C• �, ce+; •jr� � - \4� v �n 0 ll rJ. y, gyp,. FOR DETAILED e INFORMATION OF WESTFIELD SITE ID SIGN - REFER TO e SIGNAGE PACKAGE ® BY SQUARE PEG 1 DESGIN U f30'_ • 1 I I P le ',1e- AlNO WINO :�- .� 0 O Y ♦ I 1 1 1 I 1 ; �,,o�e:°:p/ -.�, ''.1 i,.:o�p / ;.': � V `� O�01 c �` �'{` 0 0 N • / •� 1 ►p� :.p �," �• T1S d015 �• •' 1 ":/ ; \_•ol -7 •'. 1 tea. A 1 I * 25-0 N .. •:.. -e� Ott' GENERAL NOTES WO 1 STRANDER BOULEVARD SIGN - AA1 el) STRANDER BOULEVARD-` SIGN - AA1 STRANDER BOULEVARD all SIGN - AA1 0 0 0 O Wes1et6 Southcenter YES -MELD DESIGN & 1160111th T•Isphm sFloor e00?�N�ps1� 4783104456 Facsimile 310 476 4466 DO DRAIN IS AA •611660rt SONCE, IK FROMM OF 11. MOVEC7 /00 UM MOT RE WPM.= Olen MRIMECTS 1.6111153011 O0 UN= REFORROCKM WOES MI AROOLLTS IUML .0E9. •40 011. NFORIRICR 008M CM It SAMOS ME SFOSIED R&M 00 NO MOT OE VSO, FOR USE WHOM MT. MORMON MU T2 MOVER Registration No. Consultants Approvals/Phase: Site Signage - Landscape Package 4/19/2007 Key Plan: a SiltiErh RAKE No. Revision Date ®- A\ 0 A A A A A A A 0 A A A A Sheet Title PROPOSED FREESTANDING SIGNAGE LAYOUT Job No. Date Seale tte acsm rasa AL1.2-1 _AIL_ Wesiliek! Southcenter WESTFIELD DESIGN & CONSTRUCTION 11601 Melte Boulevoro, 11th Floor Los Angeles, Urreernlo 90025-1748 Telephone 310 478 4456 Focalnlle 310 478 4468 Ms 1.1•0 IA OF Semi el VC AVVICMY 0.1.151. Ye CO Ka • MERCANSO wt.. AVICTECTS Ker. oul svacio gm CDC. von:Smipi pd mow YE uSI (si VC SW. Rellel oar wv, 9.1 1101 Elf kr. Registration No. Consultants Approvals/Phase: Site Signage - Landscape Package 4/19/2007 Key Plan: No. Revision A - Date A A A A A A A A A O A A A O D A D A 0 0 Sheet Title PROPOSED FREESTANDING SIGNAGE LAYOUT Job No. 1179 Dote Scale *1301 19M11•a AL 1.2-2 ISLAND eo•To`� kiKWJLq pARKbyAY CENTER TO ISLAND lT �'�l S1p PROPERTY LINE liyl. SIGNAGE CANDSCAP f AR fA ''�,,,`,� O,r p4R�/�� CUAe CA ND SCAPf AREA SIGN - AA1 1PROPERTY LINE m —_ I ----- —_ ALIGN TO STREET CURB TUKWILA PA'- WAY Illy ® LANDSCAPE PROPERTY \\ LINE NO � OPE SUPPORT POLE OF SIGNAGE V et Dv SINGLE SIDED SIG11A-C -- SIGN -M8 SIGN -M1 SIGN - AD1 © O O a� \ REPLACE AT EXISTING SIGNAGE LOCATION a c z 2 a IN SCOL I \ D1 L L• En 29'_6 ..... _ SINGLE ',DED —/ (CURB It PRUNI ¢ERTY SIGZAGE SIGN-AA1 SIGN-AD1 — — SIGN -M8 •--®••SIGN-AD1 0 0 0 _AIL_ Wesiliek! Southcenter WESTFIELD DESIGN & CONSTRUCTION 11601 Melte Boulevoro, 11th Floor Los Angeles, Urreernlo 90025-1748 Telephone 310 478 4456 Focalnlle 310 478 4468 Ms 1.1•0 IA OF Semi el VC AVVICMY 0.1.151. Ye CO Ka • MERCANSO wt.. AVICTECTS Ker. oul svacio gm CDC. von:Smipi pd mow YE uSI (si VC SW. Rellel oar wv, 9.1 1101 Elf kr. Registration No. Consultants Approvals/Phase: Site Signage - Landscape Package 4/19/2007 Key Plan: No. Revision A - Date A A A A A A A A A O A A A O D A D A 0 0 Sheet Title PROPOSED FREESTANDING SIGNAGE LAYOUT Job No. 1179 Dote Scale *1301 19M11•a AL 1.2-2 A -/-i- 6/ l ( crz-wei4,44.-g4=v4.4=te.K44.i'VVic4)4.711000a;. •-•'t • • -• • ••;,••: • • .4 At.,47,;%nr-M,..44,*,4V4,,,, ,•• `y."•:kVAIr434**1. •44,•,4k •,;•4' • , 4 • • • — , • • • 1 AA1 - Quantity: 1/4" =1'=0" 5 #5..3 -CYy 411, 6bs-oY8 6/D- � AA2 - Quantity: 3 1/4" =1'-0" AA3 - Quan Scale: NTS Sign for East Parking Structure AA4 - Quantity: 1 ifie Scale: NTS Ceo AB1 - Quantity: 3 1/4" =1'-0" m st Parking Structm% AA5 - Quan ty: 2 i --r1 Scale: NTS g 1 j 0 AA6 - Quantity:4 WOO h'3' Scale: NTS 6Q Q .91 ono NORDS`ROM SEARS 1111111:11, 1 iti) „ 41 ...3,1..15, f rsblk Jtrumw .I� 1 1 1 1 f 1 I . • 1 ��o ■ ' ' - L4 I I 1 ' 1 I I ��- ��► / 1 .1 i ' ' '- • 711111•11111111111a OLYMPIC GARAG �� Client/Design Architect Westfield Design 11601 Wilshire Blvd., 12th Floor Los Angeles, CA 90025 Graphic Consultant :I11AIE PEI en 1011 5515 Dsyle Street Suite 15 E•eryville, Culiferuie 14801 Telepkeue 511.598.1111 Fucti.ilu 511.598.8114 Project Wes1e&t Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 4/28/06 50% Design Development 6/02/06 75% Documentation 10/25/06 80% Documentation 3/30/07 95% Documentation 5/31/07 98% Documentation • 8/24/07 100% Documentation 11/09/07 Addendum A ASPD Revision Drawing Title • Sign Family f ! D MAY 1 9 2008i AD1 - Quantity: 11 1/4" =1'-0" F1 - Quantity: 6 1/4" = 1'-0" A A 7 — Q uav4-1-i "}1/ Scale; 4 T3 Drawing Number DEVELOPMENT B.01 Sign Code Key Example: AA1.01 AA1.01 Area Location > Sign Number > Sign Type Sign Type Sign Number Sign Function Front of House A=Site B=Building C=Car Park Back of House D=Site E=Building F=Car Park A=Identification B=Information C=Code D=Directional E=Regulatory F=Graphic Amenity G=Amenity/Furniture AThGeneral Sign Location Refer to LP sheets / Message Schedule for sign locations and messages Client/Design Architect Westfield Design 11601 Wilshire Blvd., 12th Floor Los Angeles, CA 90025 Graphic Consultem sou*Iu les mei* El 5615 Doyle Slreal Smile 15 Emelyrille, Delilersi. 94808 Telep64ee 518.698.6110 f ueim ile 510.596.8814 Project W5tiwt Southcenter 633 Southcenter Seattle, WA 98188 Protect Number 6307.00 Date 6/02/05 3/30/07 Document 75% Documentation 95% Documentation 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A Drawing Title Sign Code Key Drawing Number 1.01 t :I(P of ley t •;% NEW P KING STRIJQTI�RI G+2 A AA1 Main ID Pylon AA3 Mall Entry ID - Secondary AA4 Mall Entry ID - Primary AA5 Bridge Mounted Parking ID M6 Bridge Mounted Westfield ID SIGN LEGEND AB1 Restaurant Totem AD1 Primary Vehicular Directional AF1 Street Sign (Lupine Drive) • Power required • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant SOIUAEE PEC *ac.O 5515 Devle Street Suite 15 Emeryville, Califsreie 94108 Telepleee 510.588.8110 Facsimile 510-511.8814 Project ifestnekt Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A A SPD Revision Drawing Title Sign Location Plan South Site - New Mall Drawing Number LP 102.00 \1/4.N\ NORDSTROM ,ewg=,e%. rrc►Aw rl acys �:,0, eveervyn s c.116 04, Po e SIGN LEGEND AA1 Main ID Pylon AA2 Secondary ID Pylon • Power required AA3Mall Entry ID AD1 Primary Vehicular Directional • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant !OUAIE PEC mini* 5615 lisyls Streit Suite 15 Emeryville. Califoraie 04108 Telepisee 510.510.1110 Facsimile 510-511.1114 Project r Westfieff Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 11/09/07 100% Documentation Addendum A Drawing Title Sign Location Plan North Site - Existing Mall Drawing Number LP 101.00 0 MATCH: IATTHEWS PAINTS IP21246 RV 18.9 ATIN TO MATCH: MATTHEWS PAINTS MP00818 SATIN TO MATCH: MATTHEWS PAINTS MP13915 SATIN 3M TRANSLUCENT VINYL 3M TRANSLUCENT VINYIr IVORY (230-005) POPPY RED (230-143) NINE (9) 2.OD x .438wALL 8 EIGHT (8) 2.5'OD x .500wALL 6061-T6 ALUM SEAMLESS ROUND TUBE SIGN SUPPORTS ANCHOR TO FOOTING. FREESTANDING ALUMINUM TUBES AT EITHER END OF SIGN ARE SECURED BELOW GRADE WITH CONCRETE. ALL SIGN SUPPORTS WITH FINISHED END CAPS. ALL VISIBLE SURFACES PAINTED TO MATCH MATTHEWS PAINTS MP21246 LRV 18.9 SATIN. TUBES PASS-THRU SIGN CABINET. I/2' EXTERIOR GRADE FROSTED ACRYLIC WITH POLISHED EDGES I'DIA STRUTS FASTEN FROM ACRYLIC TO VERTICAL TUBE SUPPORTS 3' CHANNEL LETTERS INTERNALLY ILLUMINATED WITH SLOAN RED PS4 SHORT MODULE LEDS 8 POWERED BY SLOAN MODULAR 605. TRANSLUCENT WHITE (2447) PLEX FACES WITH TRANSLUCENT POPPY RED (3630-143) VINYL OVERLAY. I" TRIM CAP, 3' RETURNS 8 CHANNEL BACKS PAINT TO MATCH MATTHEWS MPI3915 SATIN. MOUNT FLUSH TO FROSTED ACRYLIC PANEL. I'DIA ALUMINUM STANDOFFS TO SECURE LETTERS TO SIGN CABINET AND CONCEAL ELECTRICAL CONDUIT. I'DIA ALUMINUM ROD WELDED TO VERTICAL ROUND TUBES. ACRYLIC FASTENS AT OPPOSITE END WITH COUNTERSUNK SCREW. 14.000" 'SOUTHCENTER' CABINET 2' TUBES 2.5" TUBES 6.000' 6.000• 15.000' 15.000" 18.000' 15.000' 15.000" 18.000' 15.000' 15.000"- 18.000/ A( +6 AnACMMLOn DSTA1L 15.000' 18.000' TOP VIEW 128.000' OV ' '�_ - TH ACR 106.00 ' LIC PANE 15.000" 18.000" 021Z15Ii10(a3a 9.487' 7.000" BETWEEN 15.000" ACRYLIC PANELS CABINET 116.000" 110.000' 104.000' 90.000' 36.000' 30.000• .W. FABRICATED .090 ALUMINUM TOP 8 BOTTOM END CAPS. NO VISIBLE SEAMS OR FASTENERS; ALL WELDS GROUND FOR SMOOTH EVEN APPEARANCE; ALL CORNERS 8 EDGES EASED 1/32"MAX. PAINT TO MATCH MATTHEWS PAINTS MP013915 SATIN. FABRICATED .125 ALUMINUM SIGN CABINET WITH 1/2" TRANSLUCENT WHITE ACRYLIC PUSH THRU LETTERS AND 3M TRANSLUCENT IVORY (230-005) VINYL OVERLAY. INTERNALLY ILLUMINATED WITH FLUORESCENT TUBES. NO VISIBLE SEAMS OR FASTENERS; ALL WELDS GROUND FOR SMOOTH EVEN APPEARANCE; ALL CORNERS 8 EDGES EASED I/32'MAX. �1Y TO MATCH MATTHEWS PAINTS MP00818 SATIN. RECP MAY 19 20081 COMMUNITY DEVELOPMENT ac{ (c; µ5e : Mid .. 4 `< - ..15 ago 122.000" OVERALL HEIGHT FROM GRADE NNEL LETTE'S/AC YLIC 13.386" 18.000' ROUTED LETTERS CABI © CA: INET CABI ET TO CAP ET BO TOM AP 31.640' #4's [20"x1341 31.000' 28.000' 24.000" END VIEW 138.000• SIGN FACE ELEVATION 3.000' GRADE PLUMB SIGNS, INC.9 09 (2531473-3323 FAX (253) 472-3107 WWW.PLUMBSIGNS.COM ".dos LOCATION START DATE VYFBTFBn l81$_AA1 WEBTFE D D1.10.013 BALES ROB MIIRI;1CN dettiONER TODD PETERSEN mug 1iFr-r 14 1 OF B DATE 0424.08 APPROVED BY: PILE8.61GNS AND REMAINS THE PROPERTY OF P_LWMEjSUa'NS UNTIL TRANSFER BY SALE, ALL iSGH}TS�RESERVED. ANY uNAUTIi0Rl2ED USE OR ..THIS IS AN ORIGINAL DESIGN CREATED BY SIGNATURE SII ■ MIR Miff OF 'O IISM __ _ ISOLIN DUPLICATION VUIU. RESULT IN A Si .000 CHARGE. • • ' • • 9 : • 1 V • I 1 FEED VERIFY All DIMENSIONS AND CONOMI NS BEFORE FABRICATION -i JCPenney • d'cYURE.1 1 EA • fib` • /. ,� NEW KING „ .STRU RERA". G +.2 - c4F 4.41, ;'r STRANDER 130U1 EVARD (1,719•ARC.FT 4.. AA1 Main ID Pylon AA3 Mall Entry ID - Secondary AA4 Mall Entry ID - Primary AA5 Bridge Mounted Parking ID AA6 Bridge Mounted Westfield ID SIGN LEGEND AB1 Restaurant Totem AD1 Primary Vehicular Directional AF1 Street Sign (Lupine Drive) • Power required • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant IDUIEE PEG M! n I 5515 Doyle Street Suite 15 Emeryville. Califereia 94508 T►le�laae 510.518-8110 Facsimile 510-511-1814 Project 'Westfield Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/01 3/30/01 95% Documentation 5/31/01 98% Documentation 8/24/01 100% Documentation 11/09/07 Addendum A !N\ SPD Revision Drawing Title Sign Location Plan South Site - New Mall Drawing Number LP 102.00 .—a ti i ei r x 7 7 7 RDSTRO 3 ! EvE: S v ri SIGN LEGEND AA1 Main ID Pylon AA2 Secondary ID Pylon • Power required AA3 Mall Entry ID AD1 Primary Vehicular Directional • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant 100111E EEO u! n I II 5515 Dsyls Street Suits 15 Emeryville. Cslifsruis 84505 Tslsplsus 510.518.5510 Facsimile 510.511-8814 Project Westfieki Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 B0% Documentation 02/09/01 3/30/01 95% Documentation 5/31/07 98% Documentation 8/24/07 11/09/07 100% Documentation Addendum A Drawing Title Sign Location Plan North Site - Existing Mall Drawing Number LP 101.00 10 MATCH: MATTHEWS PAINTS MP2I246 L.RV 18.9 SATIN TO MATCH: MATTHEWS PAINTS MP01351 SATIN TO MATCH: MATTHEWS PAINTS MP00818 SATIN V-3 TO MATCH: 3M TRANSLUCENT VINYL .•3M TRANSLUCENT VINYL MATTHEWS PAINTS IVORY (230-005) POPPY RED (230-143) MP13915 SATIN SEVEN (7) 2'oD x .250wALL 8 SEVEN (7) 2.5"0D x .250WALL 6061-T6 ALUM SEAMLESS ROUND TUBE SIGN SUPPORTS ANCHOR TO FOOTING. FREESTANDING ALUMINUM TUBES AT EITHER END OF SIGN ARE SECURED BELOW GRADE WITH CONCRETE. ALL SIGN SUPPORTS WITH FINISHED END CAPS. ALL VISIBLE SURFACES PAINTED TO MATCH MATTHEWS PAINTS MP21246 LRV 18.9 SATIN. TUBES DO NOT INTERSECT SIGN CABINET. FABRICATED .090 ALUMINUM SIGN CABINET WITH I/2' TRANSLUCENT WHITE ACRYLIC PUSH THRU LETTERS AND TRANSLUCENT POPPY RED (3630-143) VINYL OVERLAY. INTERNALLY ILLUMINATED WITH FLUORESCENT TUBES. NO VISIBLE SEAMS OR FASTENERS; ALL WELDS GROUND FOR SMOOTH EVEN APPEARANCE; ALL CORNERS 8 EDGES EASED I/32'MAX. PAINT CABINET TO MATCH MATTHEWS PAINTS MP01351 SATIN. FABRICATED .090 ALUMINUM TOP 8 BOTTOM END CAPS NO VISIBLE SEAMS OR FASTENERS; ALL WELDS GROUND FOR SMOOTH EVEN APPEARANCE; ALL CORNERS 8 EDGES EASED I/32'MAX. PAINT TO MATCH MATTHEWS PAINTS MP013915 SATIN. FABRICATED .125 ALUMINUM SIGN CABINET WITH I/2' TRANSLUCENT WHITE ACRYLIC PUSH THRU LETTERS AND 3M TRANSLUCENT IVORY (230-005) VINYL OVERLAY. INTERNALLY ILLUMINATED WITH FLUORESCENT TUBES. NO VISIBLE SEAMS OR FASTENERS; ALL WELDS GROUND FOR SMOOTH EVEN APPEARANCE; ALL CORNERS 8 EDGES EASED I/32'MAX. PAINT CABINET TO MATCH MATTHEWS PAINTS MP00818 SATIN. RECEIVED MAY 19 2008' GOWMNiTY DEVELOPW4T 12.000' 'SOUTHCENTER' CABINET 96.000' 82.000" CABINET 15.000' 15.000' 18.000' 15.000' 15.000' 18.000' 0'-5 ' 2' TUBES • 2.5" TUBES 0'-5 ' 18.000' TOP VIEW 104.250' OVERALL LENGTH 9.000' 'WESTFIELD" 13.000' CABINET 15.000'- 80.000" 98.000' 28.000" 22.500' OVERALL•W HEIGHT FROM GRADE 2.180' 86.000' 98.000' 92.000' R CABINET LOWER LOWER CABINET OWER 10.076' 14.000' ROUTED LETTERS CAP TOM CAP 2.180" 27.640" #4's [20'x109.5') 27.000' PLUMB SIGNS iNc. 909 SOUTH 28TH ST. TACOMA, WA 98409 (2531 473.3323 FAX (2531 472.3107 .�. . JOS NAME FILENAPIE jLOCATION MARTA= - 24.000' END VIEW 114.000" SIGN FACE ELEVATION SIDED GRADE 24.000' 3.000' WESTRE D BALES ROB MARBTON DATE APPROVED THIS IS SIGN CREATED BY PLUMB SIGNS ORIGINAL RENAL DE S THE PROPERLY OF PLUMB SIGNS UNTIL TRANSFER BY SALE. ALL RIGHTS RESERVED. ANY UNAUTHORIZED USE OR WILL RESULT IN A 81.000 CHARGE. 1e13_A2 WEBTFEID DESIGNER TODD PETERSEN 15.000' SCALE i/2' -'I' 15.000' SIGNATURE 18.000' 15.000' TOP VIEW 104.250' OVERALL LENGTH 9.000' 'WESTFIELD" 13.000' CABINET 15.000'- 80.000" 98.000' 28.000" 22.500' OVERALL•W HEIGHT FROM GRADE 2.180' 86.000' 98.000' 92.000' R CABINET LOWER LOWER CABINET OWER 10.076' 14.000' ROUTED LETTERS CAP TOM CAP 2.180" 27.640" #4's [20'x109.5') 27.000' PLUMB SIGNS iNc. 909 SOUTH 28TH ST. TACOMA, WA 98409 (2531 473.3323 FAX (2531 472.3107 .�. . JOS NAME FILENAPIE jLOCATION MARTA= - 24.000' END VIEW 114.000" SIGN FACE ELEVATION SIDED GRADE 24.000' 3.000' WESTRE D BALES ROB MARBTON DATE APPROVED THIS IS SIGN CREATED BY PLUMB SIGNS ORIGINAL RENAL DE S THE PROPERLY OF PLUMB SIGNS UNTIL TRANSFER BY SALE. ALL RIGHTS RESERVED. ANY UNAUTHORIZED USE OR WILL RESULT IN A 81.000 CHARGE. 1e13_A2 WEBTFEID DESIGNER TODD PETERSEN SCALE i/2' -'I' SIGNATURE *UM IN NM NO SII mammy ENV QSiN vhfDLLICpLTDN Dumas PADE 1 OF 7 ® COPYRIGHT 2008 PLUMB SIGNS, INC. FILO VERIFY ALL DIMENSIONS AND g Nom, . B E FABRICATION c\c' ,s 7 7 7 t A I\PRDSTRO 3 iEVE:_S Nsz 7 O q, MITA MATO, cartMcucwm racy UNE "e UNE 4 f 4 4 # l QnrF m INIsat i.o SIGN LEGEND AA1 Main ID Pylon M2 Secondary ID Pylon • Power required AA3 MaII Entry ID AD1 Primary Vehicular Directional • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant MACE !EQ men*0 5515 Doyle Strout Suits 15 Emery ills. California 04000 Telephone 510.500.8810 Facsimile 510.581.1814 Project lard Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 15% Documentation 10/25/06 B0% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A Drawing Title Sign Location Plan North Site - Existing Mall Drawing Number LP 101.00 t AA1 Main ID Pylon AA3 Mall Entry ID - Secondary AA4 Mall Entry ID - Primary AA5 Bridge Mounted Parking ID AA6 Bridge Mounted Westfield ID SIGN LEGEND AB1 Restaurant Totem AD1 Primary Vehicular Directional AF1 Street Sign (Lupine Drive) • Power required • No power required Client Westfield Design 11601 Wilshire Blvd, 11th Floor Los Angeles, CA 90025 Graphic Consultant 00000E PEO Men i*0 5515 Osyl. Street faits 16 Em.ry,ill., C.lif.rais 04100 T.Ispbtes 510.6104 110 Facsimile 510-511-1114 Project Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A /A\ SPD Revision Drawing Title Sign Location Plan South Site - New Mall Drawing Number LP 102.00 Revised GHANNEL„, LETTERS MANUFACTURE & INSTALL ONE (I) SET OF SELF CONTAINED LED LIT CHANNEL LETTERS - TRANSLUCENT WHITE (2447) PLEX FACES w/TRANSLUCENT POPPY RED (3630-143) VINYL OVERLAY. - 2' RED TRIM CAP & 5" RED RETURNS PAINT TO MATCH PMS#485 (RED). - INTERNALLY ILLUMINATE WITH SLOAN CL4-MB RED SHORT MODULE LEDs & POWERED BY SLOAN MODULAR 60S. - MOUNT OFF GLASS WALL MULLIONS WITH CUSTOM BRACKET. 5.000" 6.000" -J END VIEW [PAINT TO MATCH PMS#485 (RED -)1 EXTERIORIONIBUILIDINGISTCHMEA estfield I at E t (Pri [I IP 909 . SOUTH ( 2 5.3,)C29.19g€19 gouixiga WWW v 5 gGNi, s pcw. - TACOMA ‘1292 931O9 JOB NAME WESTFIELD SALES ROB MARSTON REV f 1DATE APPROVED BY: THIS IS AN ORIGINAL DESIGN CREATED BY PLUMB SIGNS AND REMAINS THE PROPERTY OF PLUMB SIGNS UNTIL TRANSFER BY SALE, ALL RIGHTS RESERVED. ANY UNAUTHORIZED USE OR DUPLICATION WILL RESULT IN A $1,000 CHARGE. — _ EILEALAME 1 613_,AA4 WESTFIELD REV We 7_9_013 DESIGNER TODD PETERSENL LOCATION 633 SOUTHCENTER, SEATTLE SCALE 1/2^.1' SIGNATURE @CLOW CO P1101 =V CR P&ORLITELV OM SFICIRC MOM lit73 MR CIV&@93V START DATE 06.0E08 PAGE 1 OF 2 1 0 COPYRIGHT 2008 IPLUMB SIGNS, NC. 1 all1100EINCJECIBREEMGEOCONOITIONS BEFORE FABRICATION PLUmBsiGNs conn Internally Illuminated Individual Letters. Size and Details to be developed. CONTEXT ELEVATION Scale: 3/32" = Adjacent sign type AB1 Restaurant Totem See Sheets GD111.1 - GD111.4 Client/Design Architect Westfield Design 11601 Wilshire Blvd., 12th Floor Los Angeles, CA 90025 Graphic Consultant IIIARE PEI 'ell l�e 5515 Deyle Stiest Silts 15 Eaeryeille. [Illinois 04805 Teleplene 510.590.8819 Fecei•ile 510-508-8514 Project Westfleff Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 4/28/06 50% Design Development 10/25/06 B0% Documentation 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A /H\ SPD Revision Drawing Title AA4 Westfield ID at Mall Entry - Primary Drawing Number GD104.01 AA1 Main ID Pylon AA3 Mall Entry ID - Secondary AA4 Mall Entry ID - Primary AA5 Bridge Mounted Parking ID AA6 Bridge Mounted Westfield ID SIGN LEGEND AB1 Restaurant Totem AD1 Primary Vehicular Directional AF1 Street Sign (Lupine Drive) • Power required • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant $0111111 PEIUlfli*n 5515 Duyls Street Site 15 Emeryville. Califeraie 94105 Toilettes 510.515.8110 Facsimile 510-511-1814 Project Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation /N\ 11/09/07 Addendum A SPD Revision Drawing Title Sign Location Plan South Site - New Mall Drawing Number LP 102.00 FRONT VIEW Scale: 1/4" =1'-0" 54,(464 -re.-& NOTE: Illuminated sign fabricated to comply with Westfield signage standards. Fabricated aluminum channel letters with painted retums and backs; illuminated with acrylic faces and translucent vinyl to Westfield's specification; provide stainless steel sleeves at attachment to facade; gasket dissimilar metals; with no exposed fasteners or conduiting SIDE VIEW Scale: 1/4" =1'-0" Sign Attached to grill with mechanical fasteners and 3/8" long stainless steel standoff sleeves. .IIII11NIIIIINIIIIIIIIIIIII''IIIIII11IIIBphIIIlNhlllllllllllllllllll111llllllllllllll1111'dIIIIIIIIIINIIIIIIIIINVI1IIIIIIIIIINIV!�IIIIIIIIIIIIIIIiiI1 ?I!iij SIGN PLACEMENT ELEVATION Scale: 1/8" = 1'- 0" Client/Design Architect Westfield Design 11601 Wilshire Blvd., 12th Floor Los Angeles, CA 90025 Graphic Consultant if1�A�E PES Men 5515 Doyle Street Suite 15 Err.ryvill., tslif.ruim 14801 TsIspkua. 511.59i-1111 Facsimile 511.595-5114 Project Westiwki Southcenter 633 Southcenter Seattle, WA 98188 RECEIVED Project Number 6307.00 MAY 1 9 2008 COMMUNITY DEVELOPMENT Date Document 4/28/06 50% Design Development 10/25/06 80% Documentation 3/30/07 95% Documentation 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A Drawing Title AA6 Bridge Mounted Westfield ID Sign Ouarek 1. Drawing Number GD106.01 • t A I tf_t: f AA1 Main ID Pylon AA3 Mall Entry ID - Secondary AA4 Mall Entry ID - Primary AA5 Bridge Mounted Parking ID AA6 Bridge Mounted Westfield ID SIGN LEGEND AB1 Restaurant Totem AD1 Primary Vehicular Directional AF1 Street Sign (Lupine Drive) • Power required • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant t IOIAIE PEI Min 5515 D.I.yStrut Suite 16 Emir/rills. California 84108 Telasisss 510.518.0110 Fausieils 510-511.1114 Project Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/07 3/30/07 95% Documentation 5/31/01 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A /N\ SPD Revision Drawing Title Sign Location Plan South Site - New Mall Drawing Number LP 102.00 1" thick dimensional acrylic letters; painted face & returns; stud mounted with stainless steel stand-offs KP -i) FRONT ELEVATION - West Parking Structure Scale: 1 1/2" =1'- 0" 0 c ± 6'-10" (6'-8" min.) -1--H—I I I I ©del PBC GARAGE MI 11 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 I I SIGN PLACEMENT ELEVATION Scale: 1/4" = 0" 2 NOTE: o This drawing is for design intent only, not for construction. a Fabricator is responsible for reviewing the most current project drawings as necessary to insure proper coordination of the signing elements. o Fabricator is responsible for verifying and confirming actual site conditions. o Fabricator is responsible for all shop / engineering drawings required in the fabrication and installation of the designs. 1/4" thick dimensional acrylic letters; painted face & retums; mounted with full coverage 3M VHB tape (0A.E.) Graphic treatment; Digital Print to wrap all sides of sign cabinet 3/4 i 3 in SIDE ELEVATION Scale: 1 1/2" = 1'- 0" Fabricated aluminum sign cabinet with no visible seams or fasteners; all welds ground for smooth even appearance; all comers & edges eased, 1/32" max.; with painted caps and digitally printed graphic at all sides; attach with studs or mechanical fasteners SC A 3 AJE ELEVATION - East Parking Structure Color Scheme Scale: 3/4" =1'- 0" Client/Design Architect Westfield Design 11601 Wilshire Blvd., 12th Floor Los Angeles, CA 90025 Graphic Consultant °aim PEOQe�i i411 5515 Doyle Stroot Saito 15 Eooiynillo. California 04600 Toloph000 510.500.0010 Foeaioila 510-500-0014 Project Southcenter 633 Southcenter Seattle, WA 98188 RECEIVED Project Number 6307.00 COMMUNITY DEVELOPMENT Date Document 4/28/06 50% Design Development 6/02/06 75% Documentation 9/15/06 Design Intent - Parking Structures 11/03/06 Addendum 1 Drawing Title I�QD Parking 0® et Pede$trielm Entioy agtvt,(--k( 7, 40+al Drawing Number :1`JBwort 4.000° 11.750' EO. 5.500° +/- COPY EO. 1° THICK DIMENSIONAL ACRYLIC LETTERS WITH PAINTED FACES 8 RETURNS; STUD MOUNTED OFF WALL I/2' WITH STAINLESS STEEL STAND-OFFS AND I/4'X3' EMBEDDED FASTENERS. 3/8°THICK ACRYLIC LETTERS MOUNT CENTERED ON FACE WITH (3-4) 08X1/2' SCREWS+WASHER/LETTER THROUGH BACK OF PANEL 8.500° 10.500' d WEST PARKING STRUCTURE Fabricated aluminum sign cabinet with no visible seams or fasteners; all welds ground for smooth even appearance; all comers & edges eased, 1/32" max.; with painted caps and digitally printed graphic at all sides; attach with studs or mechanical fasteners. mewing Title AA7 Parking ID at Pedestrian Level (Non -Illuminated) kQUANTITY: 1 EACH GARAGE A 8 B Crewing Number GD107 78.000' 79.000' EAST PARKING STRUCTURE 0.500° Graphic treatment; Digital Print to wrap all sides of sign cabinet END VIEW TO MATCH: MATTHEWS PAINTS MP21246 LW/ 18.9 SATIN TO MATCH: PMS0485 SATIN ST. o T SgGNSo Uu o--- TACOMA,Md913409 GLS THEM AN ORIGINAL OESlt>�11 CREATED BY —MrSatta 1013..O#17 w�iFtBD LUMB AND R ANNSl1H BY P.. I�LUMB S ARID REFRAINS THE PROPERTY OF PLUM RIGHTS REQ. ANY USE OR . O1tP1[T15TtOR1 MALL RESULT IN A (MOM CH E. _ 7DII?J P SU 1 1-1/111%1'C�r7C24—JC =NATURE �7Cts C$� ATL RSf'�f 7 •--,., 12531 BURT TRfZTt,'>� 009.10.133GF 9 B � I , .- ® COPYRIGHT, 2008 PLUMB SIGNS, INC. Hipp lrlt•1p[`m, i i mfouruluu::,•t : i i • FABRICATION 1.500' 8.500' 1-1/2' x I -I/2' x1/8' ALUM ANGL WELDED VERTICALS (SEE LAYOUT BELOW) E -I A 26.000' 3'X3'xI/8' ALUM ANG FRAME (WELD) DrWinp ITT AA7 PhafteilID at Pade'" ` * jNons1Hlumina ) f:1111111111 1 i 4- I A STRUCTURE (PARTIAL) SCALE: 3'=1' 36.000' 78.000' SIGN FACE/FRAME I'x4' ALUMINUM REC TUB 3/8'x2' BOLT ACROSS TOP 8 BOTTOM OF SIGN \(SEE LAYOUT BELOW) WELDED CAPS ON ENDS. 3'x3'x1/8' ALUM ANG FRAME (WELD) 3/8'THICK ACRYLIC LETTERS MOUNT TO FACE WITH (3-4) #8x1/2' SCREWS+WASHER/LETTER THROUGH BACK OF PANEL .090 ALUMINUM FACE ATTACHED TO ALUMINUM ANGLE FRAME WITH LORD ADHESIVE. DIGITALLY PRINTED VINYL AFFIXED TO SURFACE OF FACE & RETURNS. 3/8'x2 1/2' WEDGE ANCHOR (SEE i YOUT BELOW) 'x2'XI/8' STEEL ANGLE PLUG WELD REC TUBE TO ANGLE FRAME 36.000' 26.000' 26.000' FRAME & MOUNTING PER SIGN FACE SCALE: I-I/2'=I' 26.000' SECTION VIEW A -A SCALE: 3'=I' JOU NAME WEEITD SALES ROO MA ON REV DATE APao o mia ORIGINAL PLU 1VI B ®SIGNS, INC . 909 SOUTH 28TH ST. TACOMA, WA 98409 (2531 473.3323 FAX (253, 472.3107 „ - ' „ AME 1B19.M►7 WES FED TODD PETERSEN Dm s THRDVDESIGN OF PLUMB SIGNSNUMB UNTIL TRANSFER BY SALE, ALL RESERVED. ANY UNAUTHORIZED USE OR DUPUCATION WILL RESULT IN A 81,000 CHARGE. LD�T10N E PACE A8 ® SIGNATURE W ��mR�TS'OSR��MIS+SSR START DATE 01.10.08 2OF2 O COPYRIGHT, 2008 PLUMB SIGNS, INC. FELDVERIFY All DIMENSIONS AND COMMONS REFIRE FABRICATION NEW PAC 1 , 1 AA1 Main ID Pylon M3 Mall Entry ID - Secondary AA4 Mall Entry ID - Primary AA5 Bridge Mounted Parking ID M6 Bridge Mounted Westfield ID SIGN LEGEND AB1 Restaurant Totem AD1 Primary Vehicular Directional AF1 Street Sign (Lupine Drive) • Power required • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant •ONAIE FES *! n i * 0 5516 Doyle Strsst Saito 15 Ensryvills. Cslifarais 94108 Tslspisss 510.516.8110 Facsimile 510-591-1114 Project Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation • 11/09/07 Addendum A /A\ SPD Revision Drawing Title Sign Location Plan South Site - New Mall Drawing Number LP 102.00 FRONT VIEW Scale: 1/4" = 1'-0" NOTE: H Illuminated sign to be fabricated to comply with Westfield signage standards. Fabricated aluminum channel letters with painted retums and backs; illuminated with acrylic faces and translucent vinyl to Westfield's specification; provide stainless steel sleeves at attachment to facade; gasket dissimilar metals; with no exposed fasteners or conduiting 5q, re. t-tjv a(4' SIGN PLACEMENT ELEVATION Scale: 3/32" =1'- 0" aiw w w SIDE VIEW Scale: 1/4" = 1'-0" Sign Attached to wall with studs and 3/8" long stainless steel standoffs. Client/Design Architect Westfield Design 11601 Wilshire Blvd., 12th Floor Los Angeles, CA 90025 Graphic Consultant t SHARE PEI Sefliipe 6515 Osyle Street Slits 15 Emeryville. Celifereie 14001 Telophaoe 510.591.1111 Facsimile 511.596.5114 Project meld Southcenter 633 Southcenter Seattle, WA 98188 RECEIVED Project Number 6307.00 MAY 1 9 2OO8 COMMUNITY DEVELOPMENT Date Document 12/05/06 Site Signage 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A Drawing Title AA3 Westfield ID at Mall Entry Ouat^fiy 6 ;" timeed Drawing Number 0 -he/ 3 r�o F c scea-nc le GDIO3.O1 101 J • `• w s e SEARS [i ri 14-4 t •444 f‘'f . ;,N c. I • 4'. #.. 1 NEW KING STRI1 RE :A" 6 4.2 - rpt s •' . t 1 ., .fu, • • nP :,` `` s� j •t 3 i s- AA1 Main ID Pylon AA3 Mall Entry ID - Secondary AA4 Mall Entry ID - Primary AA5 Bridge Mounted Parking ID AA6 Bridge Mounted Westfield ID SIGN LEGEND AB1 Restaurant Totem AD1 Primary Vehicular Directional AF1 Street Sign (Lupine Drive) • Power required • No power required Client Westfield Design 11601 Wilshire Blvd. 11 th Floor Los Angeles, CA 90025 Graphic Consultant l $01111111 FES I! fl i * n 5516 Oasis Strout Slits 15 Eoaryvills. Calitaraia 94108 Talspbaee 510.510-8110 Facsimile 510-511.1114 Project Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 80% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation • 11/09/07 Addendum A /A\ SPD Revision Drawing Title Sign Location Plan South Site - New Mall Drawing Number LP 102.00 SIGN LEGEND AA1 Main ID Pylon AA2 Secondary ID Pylon • Power required AA3 Mall Entry ID AD1 Primary Vehicular Directional • No power required Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant NOAH PEO Mini IP 8 5515 Doyle Street Suite 15 Emeryville. California 04805 Telspioss 510.506.8810 Facsimile 510.510.1014 Project WesiRek! Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 06/02/06 75% Documentation 10/25/06 B0% Documentation 02/09/07 3/30/07 95% Documentation 5/31/07 98% Documentation 8/24/07 11/09/07 100% Documentation Addendum A Drawing Title Sign Location Plan North Site - Existing Mall Drawing Number LP 101.00 AA3 Mall Entry ID BB2 Dining Terrace Directory BB3 Evac. Map w/ Stair ID BB4 Misc. Room ID BC1 Elevator Code Sign BC2 Stair Core Level ID BC3 Restroom ID SIGN LEGEND BC4 Family Room ID BD1 Directional - Suspended BD2 Escalator Directional BD4 Amenity Blade BD5 Directional to Roof Pkg EB1 Stair ID - BOH EB2 Misc. Room ID - BOH EC1 Elevator ID - BOH EC2 Stair Core Level ID - BOH EC3 Restroom ID - BOH • Power required • No power required ® BOH Signs Client Westfield Design 11601 Wilshire Blvd. 11th Floor Los Angeles, CA 90025 Graphic Consultant irr soua1E PEG mini. 0 5515 Doyle Street Salts 15 Emeryville. California 94508 TelspI/ee 510-518-8110 Facsimile 510-511-1814 Project Westfiek[ Southcenter 633 Southcenter Seattle, WA 98188 Project Number 6307.00 Date Document 04/28/06 50% Design Development 06/02/06 75% Documentation 10/25/06 80% Documentation 3/30/01 95% Documentation 5/31/07 98% Documentation 8/24/07 100% Documentation 11/09/07 Addendum A /H\ SPD Revision Drawing Title Sign Location Plan Level 2 - New Mall Drawing Number LP 302.00