Loading...
HomeMy WebLinkAboutPermit S08-056 - AT&TAT&T 16425 SOUTHCENTER PKWY S08-056 BLDG MOUNTED SIGN SITE INSPECTION (PLANNING) File No. S08-056 Name of Tenant: AT&T Sign Address: 16415 Southcenter Parkway Date Photo Taken: February 20, 2009 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and meets code. CT 2-20-09 • Devtce Support Centeir Internal Information Sign (south facade of north building) Internal Information Sign (east facade of north building) Page 1 of 1 • • From: Jo Anne Monypeny To: "cthomson@ci.tukwila.wa.us" Date: 11/07/2008 9:53 AM Subject: AT&T sign permit #S08-056 for 16425 Southcenter Pkwy CC: "Neonweiss@Juno.com" Hi Courtney, As we discussed, please extend our sign permit S08-056 until February 15, 2009. AT&T has delayed construction on part of the project and the new signs will not be installed until January or February next year. Thank you for your assistance. Jo Anne Monypeny Project Manager Signtech Electrical Advertising 4444 Federal Blvd. San Diego CA 92102 Ph: (619) 527-6100 x 158 Fax: (866) 275-7712 joanne@signtechusa.com www.sientechusa.com file://C:\temp\XPGrpWise\49141014tuk-mail6300-po 1001376F76152EC 1\GW} 00002.H... 11/07/2008 City *Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 5379200290 Address: 16425 SOUTHCENTER PY TUKW Suite No: Permit Number: 508-056 Issue Date: 06/19/2008 Permit Expires On: -12.66•',2008_- 2-1 15 f OG Business: Name: AT&T Address: 16425 SOUTHCENTER PY , Phone: Property Owner: Name: ARGUS GROUP LTD Phone: Address: C/O METROVATION Contact Person: Name: PEGGY CHIRAS WITH SIGN TECH Phone: 619 527 6100 EXT 141 Address: Contractor: Name: NEON SYSTEMS INC Phone: 425-501-6447 Address: 4009 139TH PL SE DESCRIPTION OF WORK: ONE WALL SIGN AND ONE FREESTANDING POLE SIGN FOR AT&T -CB Fees Collected: $334.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 508.75 0 0 0 Wall Sign Size (sq. feet): 18.43 0 0 0 Sign Lighting: Face Residential Land: N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 433 0 Building Height (feet): 20 0 Sign Size (sq. feet): 196 0 Sign Height (feet and inches): 20 ' 0 " 0 ' 0 " Setback (feet): 27 0 Number of Sign Faces: 2 0 Planning Division Authorized Signature. Date: / 9• ve I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-056 Printed: 06-19-2008 City Olt Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hup://www.citukwila.wa.us RECEIPT Parcel No.: 5379200290 Permit Number: S08-056 Address: 16425 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 06/09/2008 Applicant: SIGN TECH INC Issue Date: Receipt No.: R08-02029 Initials: CB User ID: 0400 Payment Amount: $334.00 Payment Date: 06/09/2008 01:21 PM Balance: $0.00 Payee: PEGGY CHIRAS FOR SIGNTECH TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003202 334.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES SIGN PERMIT 000/345.830 000/322.100 84.00 250.00 Total: $334.00 3426 06/09 9711 TOTAL 334.00 doc: Receiot-06 Printed: 06-09-2008 RECEIVED JUN 0 4 2008' Drm- June 3, 2008 • Stacy MacGregor Chris Beale Department of Community Development City of Tukwila 6300 Southcenter Blvd., #100 Tukwila, WA 98188 206-433-7166 �icjntechTM • Re: AT&T, 16425 Southcenter Pkwy, Tukwila, WA 98188 Sign permit application Attached please fmd three (3) sets of design drawings, two (2) sets of structural engineering plans, an approval letter from the tenant's landlord, our check # 003202 in the amount of $334.00 ($125.00 for each sign and $84.00 for structural engineering review fee) along with the .permit application for the AT&T site at 16425 Southcenter Parkway, Tukwila, WA 98188. I understand that when the subcontracted installer arrives to,pick'up,the permit, he will apply; and pay for any electrical permits that are required for this site as,well Please let me know if I have missed any portion of the a plication4or/when the permits are -approved. Thank you so very much for all of your help these pastmonths. Sinc Peggy ChiYas Project Coordinator 619-527-6100 ext. 141 peggy@signtechusa.com Dep nt of Community Development Ci 6300 f Tukwila outhcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 431-3670 PERMIT NO. bc,.Dq.v,4 UN 04 2068' PERMANENT SIGN PERMIT APPLICATION COMMUNITY LOPMENT ,, Applican (' W Address, City, State, Zip rifec�i, Inc, Con a o Address, City, State, Zip Phone Phone CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $125 application fee per sign See back of form for examples Is your sign a: [Freestanding sign 15 or more feet in height [Pole sign with face 30 square feet or more in area 0 Wall sign weighing 400 pounds or more N any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: V$84 for structural review (if actual cost to the City is reater, you will be billed when you pick up your permit). I Construction details to describe the proposed foundation or ,/wall attachments (see back of form for examples) I Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding 1 Did building go through design review? ❑ Yes 0 No Wall 1 WALL SIGNS: #1 #2�— #3 #4 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) 'V Sign size(square feet) S O • Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. /4 / ' v Does wall sign weigh more than 400 pounds?(Y/N) Sign illumination (intemal/external/none) �p i rf -m(4 FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanofng sign is allowed per premises. a.33 I Height of building (feet). Generally, signs may not be higher than the building with which they are associated O I Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area t go S r C Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. nr 02 v Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. 01 t7 1 Number of si . n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for at signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct u0der penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tu a will met. 1/46- 36 / S� eli(4-4'1) Date (Signature pf r authorized agent) S/ VOW eelasa Address FOR OFFICE USE ONLY Zoning: Planning review by: O Denied O Issued 0 Issued with conditions Structural review required? ❑ Yes 0 No Structural review by: O Denied P:\Planning Forms\ Applications\2007 Applications \PermSign-12-07.doc O Approved 0 Approved with conditions Revised on 12-07 R1 I'e'vise pylon sign to 100 sq. ft. face, and parking sign to 5'- t.-05.12.08-sv at&t RECEN :D COMMUlei, a DEVELOPM T DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 �igntec hM 4444 Federal Blvd. San Diego CA 92102 Phone: (619)527-6100! Fax: (619) 527-6111 www.signtechUSA.com ilit44141 Ala A MEMBER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date 01/11/08 Salesperson- Arthur Navarro Coordinator Christine Mello Designer Scott Moller Scale. Noted Revisions ®2/20/08-sm A o A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 1 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to .-05.12.08-sv 27' D. U U a) 002 South Center Pkwy. 003 0�9 MI—PARKING PARKING SIGN parking lot 29'-9" 4 006 AT&T Retail store 62'-8" D 311U PLAk N.T.S. Strander Blvd. MN ITO CH REMOVED Window vinyl Window vinyl RECEIVED 'JUN 04 266a COMMUNII Y DEVELOPMENT Aerial View �o 4444 Federal Blvd. San Diego CA 92102 Phone: (619)527-61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER 0RIM18EIl {Ifi119181IIM MDISER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date 01/11/08 Salesperson Arthur Navarro Coordinator. Christine Mello Designer Scott Moller Scale. Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 2 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5'- 05.12.08-sv • EXISTING CONDITIONS RECEIVED 0 le ., atci1To 0 2008 MMUNITY DE!/ELOPfB1EIdT �igntec hTM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527.61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER P1 Aora MEMBER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date- 01/11/08 Salesperson: Arthur Navarro Coordinator Christine Mello Designer Scott Moller Scale -Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONS!B!L!TY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 3 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5' ht.-05.12.08-sv i EXISTING CONDITIONS RECEiVL JUN 0 4 2E13 COMMUNITY DEVELOPMENT �icjntec h.� 4444 Federal Blvd. San Diego CA 92102 Phone: (619)527-61001 Fax: (619) 527-6111 www.signtechUSA.com NENBER A I/ItI4iWNl W IIUBI.ICI at&t DSC MEA OF iLG�a�A South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date: 01/11/08 Salesperson: Arthur Navarro Coordinator: Christine Mello Designer Scott Moller Scale: Noted A A A A A Revisions A A A A 0 CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive ioroperty of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 4 18 R1 E001 E003 EXISTING STOREFRONT ELEVATION SCALE: 3/16"=1'-0" q,- h , (a Z. 001 003 PROPOSED STOREFRONT ELEVATION SCALE: 3/16"=1'-0" Ncnmti RECEIVED VE D 5 JUN 0 4 Ma COMMUNITY DEVELOPMENT R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5' t.-05.12.08-sv E002 EXISTING SIDE ELEVATION SCALE: 1/8" =1'-0" ±27'-10" Ca Pi 2'-11" ±12'-0„ A.F.F. Device,5upportCenterl 002 PROPOSED SIDE ELEVATION SCALE: 1/8"=1'-0" SOr,c)m) RECEIVED 'JUN 0 4 2003 COMMUNITY DEVELOPA ENT i �icjntec ht~ 4444 Federal Blvd. San Diego CA 92102 Phone: (619)527-61001 Fax: (619) 527-6111 www.signtechUSA.com A IABIZER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date 01/11/08 Salesperson Arthur Navarro Coordinator Christine Mello Designer Scott Moller Scale. Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 6 Of : 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5'-411,t.-05.12.08-sv E004 EXISTING PYLON SIGN SCALE: 1/8"=1'-0" G� vO ( c1 Co 004 PROPOSED PROPOSED PYLON SIGN SCALE: 1/8"=1'-0" RECEIVED JUN 0 4 2003 COMMUNITY DEVELOPMENT Signt¢c h.M 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-6100 ! Fax: (619) 527-6111 www.signtechUSA.com MEMBER 11 111011101LL lM 1111(431 A MEMBER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date 01/11/08 Salesperson' Arthur Navarro Coordinator. Christine Mello Designer. SCOtt Moller Scale. Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusiveroperty of Signtech and cannot be reproducedinwhole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 7 Ot: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5'-0° t: 05.12.08-sv 013 THRU • E005 E006 EXISTING STOREFRONT 2 SCALE: 3/32" =1'-0" 005 006 012 PROPOSED STOREFRONT 2 SCALE: 3/32"=1'-0" 4--tv6o,J,f--63 CSC RECEIVED VED JUM 0 2C53 COMMUNITY DEVELOPMENT gntecfr 4444 Federal Blvd. San Diego CA 92102 Phone: (619)527-6100! Fax: (619) 527-6111 www.signtechUSA.com MEMBER A MEMBER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date 01/11/08 Salesperson Arthur Navarro Coordinator. Christine Mello Designer Scott Moller Scale. Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. ; Drawing Number: 08-00604 Sheet: 8 Of : 18 R1 • R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5'-r t.-05.12.08-sv 007 EXISTING PYLON TO BE REMOVED SCALE: 1/8"=1'-0" SIGNTECH TO REMOVE, CUT OFF POLE AND CAP RECEIVED MAI 0 4 2008 COMMUNITY DEVELOPMENT �igntec hTM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date 01/11/08 Salesperson. Arthur Navarro Coordinator Christine Mello Designer Scott Moller Scale. Noted Revisions A A A n A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 9 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5' t: 05.12.08-sv 111 9'-9" 001. O (3\v-__cr2) urm-tonrr 002 CUSTOM - LIF-DSC-1-WHT-8-H- NO GLOBE NO AT&T - CUSTOM KERNING Cce_Hrnrr SCALE: 1 "=1'-0" SQ. FT: 6.0 MANUFACTURE AND INSTALL TWO (2) INTERNALLY ILLUMINATED SETS OF CHANNEL LETTERS ON EXISTING AWNINGS DEVICE SUPPORT CENTER COPY : 5" DEEP ILLUMINATED CHANNEL LETTERS FACES: .177" WHITE TRANSLUCENT ACRYLIC #2447 AND 1" JEWELITE SILVER METALLIC TRIMCAP. RETURNS: .050" THICK ALUMINUM PAINTED MATTHEWS #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. BACKS: TO BE .063" THICK ALUM PAINTED #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. ILLUMINATION: LED LIGHT SOURCE BY SLOAN LEDS AS REQUIRED FOR PROPER EVEN ILLUMINATION NOTE: The gauge of the wire is dictated by the length of the run & amperage as per NEC Article 300. - The ground wire must be continuous & go from the sign to the panelboard ground bus. - Voltage between ground and neutral should measure no more than 3 volts. - Power to the sign must be done by a licensed electrical contractor or licensed electrician. SOS'AMTQ END VIEW SCALE: 1 "=1'-0" RECEIVED 'JUN 0 4 2C COMMUNITY DEVELOPMENT Signtech 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER S: - 11131110611 EOM A MEUMER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date- 01/11/08 Salesperson: Arthur Navarro Coordinator Christine Mello Designer Scott Moller Scale- Noted A A A A A Revisions 0 A A A 0 CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 1 0 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to ht: 05.12.08-sv 1110 RETURN THICKNESS TO BE .050" ALUMINUM PAINT EXTERIOR SURFACE TO MATCH SILVER MATTHEWS 41-342, BRUSH ALUMINUM. PAINT INTERIOR SURFACE WITH SPRAY -LAT STAR BRITE LIGHT ENHANCEMENT PAINT. TRIM CAP 1" JEWELITE SILVER METALLIC. LETTER FACE TO BE .177" WHITE TRANSLUCENT ACRYLIC #2447 SLOAN WHITE LEDS • DISCONNECT SWITCH WITHIN SITE OF SIGN LETTERS BACK TO BE .063" ALUM. PAINT EXTERIOR SURFACE TO MATCH SILVER MATTHEWS 41-342, BRUSH ALUMINUM. PAINT INTERIOR SURFACE WITH SPRAY -LAT STAR BRITE LIGHT ENHANCEMENT PAINT. .063" ALUM. FABRICATED RACEWAY WITH INTERNAL ALUM. ALUM. ANGLE FRAME AS REQUIRED. PAINT TO MATCH EXISTING BUILDING COLOR. #8 TEK SCREW AS NEEDED TO ATTACH SYMBOL TO RACEWAY. TO MEET U.L. AND APPLICABLE ELECTRICAL CODES. WEEP HOLES WITH LIGHT SCREENS. AS REQUIRED. RE -SKINNED AWNING OR NEW AWNING VERTICAL SECTION (WHITE LETTERS) Scale: 3"=1'-0" ALUMINUM FABRICATED RACEWAY PAINT TO MATCH EXISITNG BUILDING COLOR .050' ALUM. SYMBOL RETURN TO MATCH SILVER MATTHEWS 41-342, BRUSH ALUMINUM. .125' ALUM. CAM CUT RING RETAINER WELDED TO .080' ALUM. FLAT STOCK. PAINTED TO MATCH SILVER MATTHEWS 41-342, BRUSH ALUMINUM. "GLOBE" .118" SG THERMOFORMED ACRYLIC (ACRYLSTEEL OR APPROVED EQ.) SECOND SURFACE DECORATE PER CALL OUTS. 1/ DISCONNECT SWITCH WITHIN SITE OF SIGN POWER UNIT SLOAN WHITE LEDS .063" ALUM. SYMBOL BACK PLASMA CUT PAINT EXTERIOR SURFACE TO MATCH SILVER MATTHEWS 41-342, BRUSH ALUMINUM. PAINT INTERIOR SURFACE WITH SPRAY -LAT STAR BRITE LIGHT ENHANCEMENT PAINT. #8 TEK SCREW STAINLESS STEEL AS NEEDED TO ATTACH SYMBOL TO RACEWAY. .125" ALUM. CAM CUT RACEWAY RING #8 STAINLESS STEEL COUNTERSUNK SCREW TO ATTACH RETAINER TO CABINET (TYP.) WEEP HOLES WITH LIGHT SCREENS. AS REQUIRED. U�q OjLlrr. DOlI1' yr, pllIIIIIIIIIUIPII Mit 1111. 11 �I RE -SKINNED AWNING OR NEW AWNING O WEEP HOLE VERTICAL SECTION @ SYMBOL Scale: 3"=1'-0" RECEIVED Ilk. JUN O 4 2000 DCOMMUNITY �igntec hTM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER A u1uumw w ewww MEMBER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date• 01/11/08 Salesperson: Arthur Navarro Coordinator. Christine Mello Designer. Scott Moller Scale Noted A A A A A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 11 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to ght.-05.12.08-sv 1'-81 /2" 1 1/2" 1 1/4" 1 1/2" 2 3/8" 1" 3/1 1 5/8" 1" 1 5/8" 1' 3/4'�- 1" 1'-4 7/8" Dawke Supp© CSRUF n Onlorie wurrargay EmehaRge 0 VechutQad Suppol n Daft® and Lquopmaw Trirdang 1/2"i 13/4" SCALE: 1 1/2"=I-0" 003 V -DSC -CUSTOM VINYL • MANUFACTURE AND INSTALL ONE (1) SET OF WINDOW VINYL ALL COPY: TO BE 3M FILM #7725-10 WHITE ALL TO BE APPLIED FIRST SURFACE. n0A]PZ GAOm-Full Seotag Sunday SMOCum 900 Dpl HO CASH AU MOS LO©z F00a 1 1/4" 1 3/8" 7/8" /\J7 Device Support Center • Onsite Warranty Exchange • Technical Support • Device and Equipment Training Hours Mon -Fri 10:OOam - 9:OOpm Saturday 10:OOam - 7:OOpm Sunday 11:00am - 6:OOpm NO CASH AT THIS LOCATION TYPICAL INSTALL SCALE: 3/4"=1'-0" aZi-riMst RECEIVED JUM042G3 COMMUNITY DFVFI nPMFNT �igntec hTM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com A I MB ROF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date• 01/11/08 Salesperson Arthur Navarro Coordinator. Christine Mello Designer. Scott Moller Scale- Noted A A A A A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 12 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to ht.-05.12.08-sv • ii 10" 4" 14'-0" 4' 10" \ 7 7/8" / EQ 3'-7 7/8" 6'-10" EQ 2'-0" 10" I ,' \ 8 5/8".� $.�a� *&. i , , > r, <„ , (-7.) 5'-9 3/8" y , , 6-)N ,. / a fir." z i x.. .° . 2'-0 1/2„ — — } i , 1 , 98 SQ. FT. (PER FACE 1 1 / , , ©'4:1 ' A.F.F. t 01- / 1 � I 4 \ (do 6a - r -2e-:,4-/ - 004 CUSTOM ILLUMINATED PYLON SIGN MANUFACTURE AND INSTALL ONE (1) INTERNALLY ILLUMINATED D/F PYLON SIGN CABINET: .125" ALUMINUM FABRICATION PAINTED MATTHEWS 31-342 BRUSHED ALUMINUM. STAINLESS STEEL PIANO HINGE (CONTINUOUS) AT TOP FRAME: TO BE .125" ALUMINUM ANGLE FACE FRAME. USE CHANNEL AT TOP FOR HINGE ATTACHMENT. MITER CUT, WELD AND GRIND SMOOTH AT CORNERS. PAINT MATTHEW 31-342 BRUSHED ALUMINUM. FACE: TO BE .125" THICK ALUMINUM PAINTED MATTHEWS 31-342 BRUSHED ALUMINUM. GLOBE: TO BE ROUTED OUT OF FACE AND PUSHED THRU. TO BE .118" CLEAR SG 4/ THERMOFORMED ACRYLIC (ACRYSTEEL OR APPROVED EQ) SECOND SURFACE. DECORATE WITH VINYL AS SHOWN IN VINYL DETAIL. at&t: TO BE 3/4" THICK CLEAR PLEX ROUTED OUT OF FACE AND PUSHED THRU 1/2". DECORATE WITH 3M 3635-222 BLACK VINYL. BACK UP SECOND SURFACE WITH .177" #2447 DIFFUSER WHITE PLEX ILLUMINATION: TO BE SLOAN WHITE LEDS. , ` ,;> A. FRONT VIEW SCALE: 3/8"=1'-0" SCALE: 3/8"=1'-0" FEC EIVr_0 JUN 0 4 2060 COMMUNITY DEVELOPMENT �igntechM 4444 Federal Blvd. San Diego CA 92102 Phone: (619)527-61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER A IIMIDSLLINISSOOITIN MEMBER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date- 01/11/08 Salesperson Arthur Navarro Coordinator: Christine Mello Designer Scott Moller Scale -Noted 0 A A A A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 1 3 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to ';,'ght.-05.12.08-sv 2'-8 1 /8" OOg 8'-1 1/2" 2'-8 1/8" 5 5/8' 4'-11 7/8" LOF-G°-W1-1T 244I1 1/2 2'-0" 101/2" SCALE: 3/4"=1'-0" SQ FT: 2 1/8" MANUFACTURE AND INSTALL ONE (1) INTERNALLY ILLUMINATED SET OF CHANNEL LETTERS AND LOGOS WITH RACEWAY GLOBE LOGO: 5"DEEP FACE: .118" CLEAR SG THERMOFORMED ACRYLIC (ACRYSTEEL OR APPROVED EQ)SECOND SURFACE DECORATE WITH VINYL AS SHOWN IN VINYL DETAIL WITH .125" ALUM. RETAINER PAINTED #41-342 BRUSHED ALUMINUM SATIN FINISH. RETURNS: .050" THICK ALUMINUM PAINTED MATTHEWS #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. BACKS: TO BE .063" THICK ALUM PAINTED #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. AT&T: 5" DEEP FACES: .177" WHITE TRANSLUCENT ACRYLIC #2447 AND 1" JEWELITE SILVER METALLIC TRIMCAP. RETURNS: .050" THICK ALUMINUM PAINTED MATTHEWS #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. BACKS: TO BE .063" THICK ALUM PAINTED #41-342 BRUSHED ALUMINUM SATIN FINISH PAINT INSIDE OF LETTER WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. ILLUMINATION: LED LIGHT SOURCE BY G.E. GELCORE AS REQUIRED FOR PROPER EVEN ILLUMINATION RACEWAY: .063" ALUM. FABRICATION, PAINTED TO MATCH PMS #1505 ORANGE END VIEW 3M #3635-30 WHITE DIFFUSER FILM SECOND SURFACE 3M FILM #3630-8015 -_____-- DARK BLUE SECOND SURFACE .118" CLEAR SG THERMO- FORMED ACRYLIC DOME 3M #3630-8071 LIGHT BLUE SECOND SURFACE LOGO COLOR VINYL DETAIL .118" THERMOFORMED CLEAR ACRYLIC FACE 3M FILM #3630-8015 DARK BLUE SECOND SURFACE 3M #3630-8071 LIGHT BLUE SECOND SURFACE 3M #3635-30 WHITE DIFFUSER FILM SECOND SURFACE CDLOGO VINYL APPLICATION SCALE: 1 1/2"=1'-0" NOTE: The gauge of the wire is dictated by the length of the run & amperage as per NEC Article 300. - The ground wire must be continuous & go from the sign to the panelboard ground bus. - Voltage between ground and neutral should measure no more than 3 volts. - Power to the sign must be done by a licensed electrical contractor or licensed electrician. (RECEIVED 'JUN 04 2eGa COMMUNITY DEVELOPMENT 6[1 n dch. 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER 410 umMroeufmraanNl MEMBER OF at t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date• 01/11/08 Salesperson Arthur Navarro Coordinator Christine Mello Designer Scott Moller Scale Noted Revisions 0 A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 1 4 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5' ht.-05.12.08-sv 3'-6" 3'-6" ±8'-81/2" SCALE: 3/16"=1'-0" 0 4 ±50'-4 1/2" SCALE: 3/16"=1'-0" T 006 4 3'-6" 2'-0„ END VIEW SCALE: 3/4" =1'-0" SCALE: 3/16"=1'-0" MANUFACTURE AND INSTALL THREE (3) INTERNALLY ILLUMINATED AWNINGS AWNING FRAMES: TOBE OF ALL ALUMINUM CONSTRUCTION AWNING MATERIAL TO BE ARLON COLORKOTE SYSTEM. BASE ORANGE, AT&T ORANGE TC2-173 TANGERINE ILLUMINATION: TO BE 800 MA FLUOR. LAMPS AS REQUIRED RECEIVED JUN 0 4 20Gd COMMUNITY DEVELOPMENT �igntec h. 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com A MEMBER OF Ilmom iiA at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date• 01/11/08 Salesperson Arthur Navarro Coordinator Christine Mello Designer Scott Moller Scale Noted A A A A A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 1 5 Of : 18 R1 fil • R1- Revise pylon sign to 100 sq. ft. face, and parking sign tofight -05.12.08-sv +1,_2„ +1,_3„ +5'-0R 007 008 009 MANUFACTURE AND INSTALL (3) THREE SETS OF WINDOW VINYL VINYL TO BE DIGITALLY PRINTED 013 014 015 016 017 018 019 SCALE: 1 1/2"=1'-0" 020 MANUFACTURE AND INSTALL (8) EIGHT SETS OF WINDOW VINYL VINYL TO BE DIGITALLY PRINTED +1,_7„ SCALE: 1 1/2"=1'-0" ±2'-10" 021 022 SCALE: 1 1/2"=1'-0" MANUFACTURE AND INSTALL (2) TWO SETS OF WINDOW VINYL VINYL TO BE DIGITALLY PRINTED SIAC"OTItO RECEIED JUN 0 4 2E53 COMMUNITY OEvtLUrwttt 1 �icjntec hTM 4444 Federal Blvd. San Diego CA 92102 Phone: (619)527-61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER A muumnutwauatm MEMBER OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date: 01/11/08 Salesperson- Arthur Navarro Coordinator Christine Mello Designer. Scott Moller Scale Noted 0 A A A A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 16 Of : 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to 5-ght: 05.12.08-sv Charleston Industries 225SP Standard Post Extrusion Weld mounting bracket to face t i .125" aluminum face Center mount bracket Section "Y" Soak Hag • 145. .125" aluminum face Aluminum background painted Matthews MP30136 Brushed Aluminum Rear sdark gray ALUMINUM FABRICATED BASE WITH CONCRETE INSIDE r CONCRETE 010 mi"a`4 irfat:a 4iskirI., /A.Y • • a • a' • n 011 it.paiedirojv Ova Front Elevation Soak Ott o" CU$TOM4 REGULATORY::: Side Elevation MANUFACTURE AND INSTALL (2) TWO NON -ILLUMINATED POLE MOUNTED REGULATORY SIGN MANUFACTURING SPECIFICATIONS ABOVE. 72 9„ RECEIVED ►JUM 0 4 200 COMMUNiTY DEVELOPMENT 5 Al 650-55 ,P.igec:. 84i V.1/ sr* UNAUTHORIZED VEHICLES WILL BE TOWED AWNERS _ EXPENSE�t Aluminum background painted Matthews MP30136 Brushed Aluminum J,N 6,50-55 Aga:. Bkal Pas le.: dIl tc4.v /Paw 1%,+l Oaf ALUMINUM BASE YL TO BE DIGITALLY RINTED Regulatory Sign (Detaily;, 1 • �igntec hTM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-61001 Fax: (619) 527-6111 www.signtechUSA.com MEMBER A 111111Mal4N 11101101 IAElaiEll OF at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date' 01/11/08 Salesperson. Arthur Navarro Coordinator Christine Mello Designer. Scott Moller Scale. Noted Revisions A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 1 7 Of: 18 R1 R1- Revise pylon sign to 100 sq. ft. face, and parking sign to ght.-05.12.08-sv 1'-4 1/4" 1'-4 7/8" ALL COPY TO BE WHITE VINYL 3 3/4" 012 5/8" 1 1/4" 1 3/8" 7/8" V-1 1 5/8" 3 7/8" o11D-lir, 000zED =ao©opw� SE uday a00RIM -0:00prini Sunday 50000 00 agn— 30pRim • ALL COPY TO BE WHITE VINYL SCALE: 1 1/2"=1'-0" Store Hours Mon -Fri 8:OOam-5:OOpm Saturday 8:OOam-6:OOpm Sunday 10:OOam-4:30pm MANUFACTURE AND INSTALL ONE (1) SET OF WINDOW VINYL LARGE GLOBE LOGO: TO BE DIGITALLY PRINTED ONTO 3M DUAL COLOR FILM #3635-210 WHITE. SMALL GLOBE: TO BE DIGITALLY PRINTED ONTO 3M IJ -8171-10 WHITE. GLOBE TO BE PRINTED FULL COLOR 600 DPI. OVERLAMINATE WITH 3M #8914 CLEAR. ALL OTHER COPY: TO BE 3M FILM #7725-10 WHITE ALL TO BE APPLIED FIRST SURFACE. STORE HOURS TO BE CONFIRMED TYPICAL INSTALL SCALE: 3/4"=1'-0" SO154Amit() RECEI'IED JUN 0 4. 3 J3 COMMUNITY DEVELOPMENT �igntec hTM 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-6100 ! Fax: (619) 527-6111 www.signtechUSA.com A MEMBER OF %ND G� �DIrK vail at&t DSC South Center Parkway 16415 South Center Parkway Tukwila, WA 98188 Date 01/11/08 Salesperson. Arthur Navarro Coordinator. Christine Mello Designer Scott Moller Scale- Noted n A A A A Revisions A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature Date This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 08-00604 Sheet: 18 Or: 18 R1 16'-4" 14'-0" 4"l 0 Ln rn N 0 0 N 0 0 NOTES: SIGN CABINETS & CONNECTION DESIGN BY OTHERS. ELECTRICAL DESIGN BY OTHERS. -00 rn 10"x10"x1/4" STEEL TUBE 0 N 6' 5' 0"-----I RECEIVED Jy 0 1.08 COIV MtJ!,l I Y DEVEL.OP:U T GRADE (5) #4 VERTICAL BARS 13" O.C. WITH (6) #4 HORIZONTAL BARS © 15" O.C. ON THE WINDWARD & LEEWARD FACES OF THE FOUNDATION 3.89 CU. YDS. 5' 0" OF CONC. REQ'D. /OVER TURN/ 2' -0" L3' -0"J 1/2" DIA. A325 BOLT 8"x 1 3/4"x1/4" STEEL CHANNEL 1" DIA. PIPE SPACER CONNECTION DETAIL 10"x10"x1/4" STEEL TUBE GRADE 0 Yj 8'-6" EMBEDMENT • 3'-0" DIA. J 2.36 CU. YDS. OF CONC. REQ'D. PER CAISSON OPTIONAL CAISSON FOUNDATION 10"x10"x1/4" STEEL TUBE NO1E: AS design Old pons Mcoled on the era.1g ore the sok properly 01 1010 Engneeny LLC, created speed -may kr the noted procl. Use of (hem deign or plans la my expose other Ulm the attended application shalt be prohihiled .ilhad the kitten consent al LM( Engneerky. LLC. Disclosure el my o1 the nlanution 011110501 .ilhn, without consent of pater. 0 0 :olden of 0100.lud properly end SW not be (derated INSTALLATION ADDRESS: AT&T MOBILITY 16425 SOUTHCENTER PKWY TUKWILA, WA 98188 CLIENT:4444 FEDERAL BLVD. "' SAN DIEGO, CA 92102 PHONE: (619) 527-6100 FAX: (619) 527-6111 SHT. OF ivG/NE---F/NGJ 1 2 LINK Engineering, L.L.C. 9051 Executive Pork Dr.. Ste. 200 • Knoxville. TN 37923 Phone: (865) 539-4001 • Fox: (865) 539-0851 Online: www.linkengr.corn BY: HMA DATE: 05/19/08 Project Number: 08-0646 Drawing Number: B229001 SIGN COLUMN OAH SIGN COLUMN VERTICAL SLAB MOMENT FORCE PROJECT# 08-0646 OWNER AT&T MOBILITY May 19. 2008 :16425 SOUTHCENTER PKWY DRAWNG # B229001 :TUKWILA, WA 98188 WIND LOAD 22.290 PSF WIND SPEED 85 000 MPH CLIENT ' SIGNTECH 4 COLUMNS 2 000 IBC 2006 i4444 FEDERAL BLVD ENGINEER GAC 'SAN DIEGO, CA SHAPE ' CENTROID TOTAL WIDTH 7 FACTOR HEIGHT AREA I FORCE MOMENT • HEIGHT 7 000 13 000 20 000 16 333 1 000 3 500 114 333 2 548 8 920 1 667 1 667 6 500 36.110 3 353 47.282 COLUMN STRESSES (CODE P=PIPED=OTHERT=TUBE) OBLIQUE COLUMN OBLIQUE Sxx COLUMN ' COLUMN ,. txx • Sxx ACTUAL ALLOWABLE LOAD CENTER LOAD MOMENT REQ'D DEPTH WALL COLUMN COLUMN STRESS STRESS STRESS DISTANCE FACTOR 8 920 1 322 10 000 0 250 142 0 28 40 1.885 30 360 2.679 • 15 500 1 422 47 282 7 008 10 000 0 250 142 0 28 40 9 990 30 360 14 201 33 606 FT -KIP 2 383 KIP RtrtRENCE IBC 1805 7 2 & TABLE 18042 ASSUME SOIL CLASS #5 CL, ML. MH & CH LATERAL BEARING PRESSURE - PSF/FT OF DEPTH 100 0 PSF/FT Si 4667 • SLAB DEPTH (d) 7 000 FT 'SLAB W_ IDTH (b) ' SLAB THICKNESS 5 000 FT 3 000 FT. ,AVERAGE HEIGHT (h) 14 100 FT A = 2 34•FORCE/(S1'b) 2 050 CALCULATED DEPTH 6 730 FT MINIMUM THICKNESS WTHOUT REBAR 19 039 IN SORT(M'12'6'1 7. 75/( 178'121IVIDTH)) ACTUAL THICKNESS 36 000 IN CONCRETE 3 889 CU YD EXCAVATION 3889 CU YD CAISSON MOMENT FORCE RtrtHENCE IBC 1805 7 2 & TABLE 18042 ASSUME SOIL CLASS #5 CL, ML, MH & CH LATERAL BEARING PRESSURE - PSF/FT OF DEPTH Si DEPTH DAME I tH CALCULATED DEPTH . MINIMUM THICKNESS WITHOUT REINFORCEMENT ACTUAL DIAMETER 33 606 FT -KIP KIP 2 383 100 0 PSF/FT 600 0 9 000 FT 3 000 FT 14 100 FT 3 098 FT 8 622 FT. 35 363 IN 36 000 IN • __ CONCRETE 2 356 CU YD 'EXCAVATION 2356 CU YD NOTES: 1. Design is based on 85 mph 3 sec gust design wind speed per IBC 2006. Exposure C. 2. Foundation is based on a safe lateral soil bearing pressure minimum of 150 psf per foot of depth. Soil report was not furnished. Allowable bearing pressure should be verified prior to placement of concrete. Do not place foundation in fill. 3. Concrete shall be mixed to attain a minimum compressive strength of 2500 psi in 28 days. 4. Support member shall be free from defects and shall meet ASTM A500 grade B with a minimum yield strength of 46000 psi for tube. Plate and angle shall meet ASTM A36. 5. Structural bolts shall be zinc coated A325 unless otherwise noted. 6. Welds shall be made with E70xx electrodes by persons qualified in accordance with AWS standards within the past two years. 7. Steel reinforcing bars shall conform to ASTM 615 grade 60 with deformations in accordance with ASTM A-305. Welding of reinforcing bars is prohibited. 8. This design is intended to be installed at the address shown below and should not be used at other locations unless deemed suitable by a competent Professional Engineer. Sod - asci RECEIVED JUN 0 4 2008 COM?v€1 Y DO`jr NOTE: Al deign cod plass 0dealed on the &o.:q me the sole properly of LDUI Capita:Mb LLG created spec:k:W), W the noted project. Use of the deign or plass for my purpose other Ikon the intended application shod be prohibited .ilhml the written consent of Lea En4neeriy LLC. Disclosure el my of the i formedion enclosed .11hn..iho.1 cement of mom is o :doles of Oldlectaal 70.7.01) cod shall not be lobated i 7 INSTALLATION ADDRESS: AT&T MOBILITY 16425 SOUTHCENTER PKWY TUKWILA, WA 98188 t `0 CLIENToigntech"SAN 4444 FEDERAL BLVD. DIEGO, CA 92102 PHONE: (619) 527-6100 FAX: (619) 527-6111 LINK Engineering, L.L.C. SHT. OF 2 2 9051 Executive Pork Dr.. Ste. 200 • Knoxville, TN 37923 Phone: (865) 539-4001 • Fox: (865) 539-0851 Online: www.linkengr.com BY: HMA DATE: 05/19/08 Project Number. 08-0646 Drawing Number: B229001