HomeMy WebLinkAboutPermit S08-094 - RAINIER INDUSTRIESMITEL
14240 INTERURBAN AVE S
S08-094
BUILDING MOUNTED
SIGN
File No.
Name of Tenant:
Sign Address:
Date Photo Taken:
x
SITE INSPECTION (PLANNING)
S08-094
Mitel
14240 Interurban Ave S.
October 9, 2008
Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of XX/XX/200X
Make new site visit and take photo by XX/XX/200X
Comments: Sign inspected and meets code. CT 10-09-08
City ofrukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
PERMANENT SIGN PERMIT
Parcel No.: 3365901881
Address: 14240 INTERURBAN AV S TUKW
Suite No:
Permit Number: S08-094
Issue Date: 09/26/2008
Permit Expires On: 03/25/2009
Business:
Name: MITEL
Address: 14240 INTERURBAN AVE S ,
Phone:
Property Owner:
Name: DBSI FAIRWAY LLC 519999 Phone:
Address: C/O DDRS TAX DEPT
Contact Person:
Name: DANIELLE HACKETT Phone: 425-251-1800
Address: 18375 OLYMPIC AVE S
Contractor:
Name: RAINIER INDUSTRIES Phone: 425-251-1800
Address: 18375 OLYMPIC AVE S
DESCRIPTION OF WORK:
Permit for 1 wall sign.
3 internal info signs- no permit required per TMC 19.22.030
1 non -illuminated wall sign under 4 sq feet.- no permit required per TMC 19.12.050 (6)
Fees Collected: $125.00
PERMANENT SIGN:
Zoning: C/LI Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 1600 0 0 0
Wall Sign Size (sq. feet): 13.2 0 0 0
Sign Lighting:
Face Residential Land: N
Freestanding Sign #1
Street Frontage for Entire Lot: 0
Building Height (feet): 0
Sign Size (sq. feet): 0
Sign Height (feet and inches): 0 ' 0 "
Setback (feet): 0
Number of Sign Faces: 0
Freestanding Sign #2
0
0
0
0' 0"
0
0
Planning Division Authorized Signature: _.01.1 Li w ..A 4_ .111 *♦
Date: /2(/cg
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
doc: SIGN -PERM S08-094 Printed:
09-26-2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 3365901881 Permit Number: S08-094
Address: 14240 INTERURBAN AV S TUKW Status: PENDING
Suite No: Applied Date: 09/23/2008
Applicant: RAINIER INDUSTRIES LTD Issue Date:
Receipt No.: R08-03336 Payment Amount: $125.00
Initials: CT Payment Date: 09/23/2008 02:44 PM
User ID: 1655 Balance: $0.00
Payee: CURT FOR RAINIER INDUSTRIES
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 53903 125.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
SIGN PERMIT
000/322.100 125.00
Total: $125.00
L'.'.' - ?`07 TOTAL 4t)
Lw.3-: .
tint+• Raraini-nR
Printed: 09-23-2008
Ciof Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100
Tukwila, Washington 98188
206)431-3670
PERMIT NOCCB 0 1161
Please print
►ua
tar DIOS
•
Brminocc mo Address of Sign • Phone Leap
''�r a •�t)i�ll21 1 3"15 ()\4"'ALS .-1C. �c�li0 [� -
Ad1 (.JU
ApplicantlContact dress, City, State, Zip Phone
DEVELOPMENT
Contractor Address, City, State, Zip
Phone
CHECKLIST
❑ 3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
❑ Sign elevations with area calculations and dimensions
❑ Building elevations (for wall signs)
O Supporting structure and method of illumination
❑ One copy of valid Washington State contractor's license
O $125 application fee per sign
See back of form for examples
Is your sign a:
❑ Freestanding sign 15 or more feet in height
❑ Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
If any of the above are true, the application must go
through structural review.
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
❑ Construction details to describe the proposed foundation or
wall attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestandin
Did building go through design review? 0 Yes
❑ No
Wall
WALL SIGNS:
#1
#2
#3
#4
Wall area (length x height) of the tenant space where then
sign will be mounted? (square feet)
,� • p`
Sign size(square feet)
a • o -S
,
Does sign face residential zones or public facilities? (Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
Does wall sign weigh more than 400 pounds?(Y/N)
N
4
Sign illumination (internal/external/none)
tn>ovvt_
. . M1'`
FREESTANDING SIGNS: _
\ #1
#2
Street frontage of the entire premises where the sign will be located (fee . Generally, only
one freestanding sign is allowed per premises.
Height of building (feet). Generally, signs may not be higher than the building with which they
am associated
Size of sign face (square feet). Structural review is required for pole signs with faces 30 square
feet or more in area
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
Distance from closest edge of sign to property lines (feet). Generally, signs must be set
back from all property lines a distance equal to their height.
Number of si • n faces
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for foo ing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that
the applicable requirements of the City • • • 'la will be met.
Date
Zoning:
n . naturp . Q er o thori • - nt Email Address
�w
FOR OFFICE USE ONLY
Planning review by:
❑ Denied
0 Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
O Denied 0 Approved 0 Approved with conditions
P:\Planning Forms\ Applications\2007 Applications\PermSign-12-07.doc
Revised on 12-07
1(09/26/2008) DCD-Intern Intern - Peak aving.pdf
dS
din logo
1/7 tM1 pairted a1mirvm
logo, Mooted lova/
17 eammff
-8' tall
Oro Ibak Pool Canopy
Twide x 3-St311 x 5'deep
WNe vinyl applied tomropy
MAIN MINCE Rttlar07
MITEL
Wad Order: 1)43]1
Pro
ClientMtaL
Client Contact:
Salesperson. WIIard Pack
Project Manager: _
TN -Ac
Sueshak: -•T
FinisheJ Dv -tensions
Panel 1]rrensions JAL
0iava. 07 M Tuan,
mk Proof Creak& 07-28-08
Pevse&
• aainreatta,,,,.wa.a
wittrodtitattaayr d8,ftt r ve 00€0m
~�S Aeat>MFaid
IwMtwra uralmgriprlwa
•iYlak®a it rntMtl Op,,o. /tab
IeyN. purir5rq eN tirremona worm
colynArtoyountatandroalbrrost.wor
ctlorana IvgalM.
(qf \\\
• 12 .OSO (
Lt nC1 e vo
PrrOwo ea is
4 J 'e=katy..a
�qnA re.S •ab
Sqn and lax Pack In aci-Libor ,
Ped To n,e opener n Or rdv a3 r.r,et
/1)
c6>oL.t►re Ck
Page 1
(09/26/2008) DCD-Intern Intern - 124369
rill
2.050
dge_awning.pdf_
Wedgepwning
7'widec 3' tall c 4' deep
(IA" tress)
.L41/- —SOLUTION CENTER
4
ROW CMtPI
CITY (1)
ti
2 s (D
3075
OLUTIO
CENTER
SCECFCMCFY
CITY(2)
MITEL
vark Aden 121301
Moro. fallei
CM [ tag_
Ceent Conlad:
Saaanervi: w1a
Morena Manager: M
s.waa,
Rama Oa.md.na o
Peirl Dermarm kt&
Donn BY: E1I.deL
Orta Proof Owed: 074Moa
Rea: MEM.
• ..e..am,aPwendnwe,
ImafronunMorearadmknorOannaPn
antramtMaprommornornanoMend
ewes. aa,r.aPnroau.a
r.p. Pvei., and mmmravIrriw.
�
.n oyoumdfeapmbmlrM
wry.
o PPM.. on is
o Ftnlow loth cn.nwe
o FMk. cdrr.c,ionee.a.nd
%magart pro
to and b. LIMA lir 1:a..1.01P
F1.1h➢,an1131tnOt FdV &t
info. Sig)r)s -tot. nci Prm i t requirea
undo( (10
TMG I°I.22. d 30
q12uf°%
•
•
j14240 INTERURBAN AVE S
SUITE 170
TUKWILA, WA 98168
PROPOSED NEW CANOPY
INTERURBAN AVE S
Plot Plan
Scale: 3/16" 1'-0"
File Name: P:\DTSIDEVELOPMENT1Mite11124371 - peaked canopy\124371.dwg
GARDEN
RECEIVED
SEP 2 3 2008
COMMUNITY
DEVELOPMENT
�PRO
JECT M e SALES a DTS a FRAME / ASSEMBLY a FABRIC a GRAPHICS e INSTALL 0 WOOD SHOP 0 SHIPPING e
Rainiierindushies, Lid
18435 Olympic Ave. S.
Tukwila, WA 98188
800-869-7162 Toll Free
425-251-1800 Phone
425-251-5065 Fax
www.Rainier.com
Original design concepts are protected
under Federal Copyright Laws and
are the property of Rainier Industries, Ltd.
Any reproduction of this design concept
without written consent is expressly
forbidden.
ISO 9001:2000 REGISTERED
MREL
14240 INTERURBAN AVE S
STE 170
TUKWILA, WA 98168
Revisions
WILLARD PARK
Sales Person
PEAK ROOF CANOPY
Job Name
PLOT PLAN
Drawing Title
124371
RI Work Order Number
TED S MARIER
Drawn By
ZAC ROGER / 8-20-08
Checked By / Date
DAVE TAQUINO
Project Manager
--/—
Issue Date / By
P1.00
Sheet Number
r.
5'-8"
• •
PROP 1= D NEW WALL SIGN
7'-0"
•
EF7F = Ic000�'
P-ttowed (o8o
Th{-. S;Sr, fly. _ 13.20
i0,4°-Pt'a-cjea-
12C.0_
t
CV
MITEL
PROPOSED NEW CANOPY
1
West ElevationrViewo
Scale: 3/8"=1-0
File Name: P:IDTSIDEVELOPMENTIMite11124371 - peaked canopy1124371.dwg
5-0"
South Elevation View
Scale: 3/8" -1
RECEIVED
SEP 2 3 2008
COMMUNITY
DEVELOPMENT
RainierIndusbies, Lid
18435 Olympic Ave. S.
Tukwila, WA 98188
800-869-7162 Toll Free
425-251-1800 Phone
425-251-5065 Fax
www.Rainier.com
Original design concepts are protected
under Federal Copyright Laws and
are the property of Rainier Industries, Ltd.
Any reproduction of this design incept
without written consent is expressly
forbidden.
ISO 9001:2000 REGISTERED
MITEL
14240 INTERURBAN AVE S
STE 170
TUKWILA, WA 98168
Revisions
WILLARD PARK
Sales Person
PEAK ROOF CANOPY
Job Name
ELEVATION VIEWS
Drawing Title
124371
RI Work Order Number
TED S MARIER
Drawn By
ZAC ROGER / 8-20-08
Checked By / Date
DAVE TAQUINO
Project Manager
Issue Date / By
elm
e MASTER a PROJECT MGR a SALES a DTS 4 FRAME / ASSEMBLY a FABRIC o GRAPHICS 4 INSTALL a WOOD SHOP a SHIPPING 4 Sheet Number
P2.00
• "314'x3/4"x.110 ALUM. TUBE
•
O1"x1"x.110 ALUM. TUBE
• 1"x1"x.110 STAPLE EXTRUSION (OUT)
• 1"x1"x.110 STAPLE EXTRUSION (UP)
• 1"x1"x.110 STAPLE EXTRUSION (BACK)
• 1"x2"x.125 STAPLE EXTRUSION (DOWN)
O7 1"x2"x.125 ALUM. TUBE
•
•
44(Wt4
co fro 4fri
INk 01r
0
Isometric View
Scale: 1/2" =1'-0"
File Name: P:IDTSIDEVELOPMENTIMite11124371 - peaked canopy1124371.dwg
NOTES:
• FRAME
• FRONT: 7'-0"
• WALL: 3'-6"
• PROJ: 5'-0"
• TRUSS: 1'-0"
• MATERIAL FINISH: MILL
• ASSEMBLY
• FABRIC: WEBLON #CP2712 DEEP SEA BLUE
• GYMP: #13 DARK BLUE
• LIGHTING: NONE
• FABRIC ATTACHMENT: STAPLE
• GRAPHICS
• ON FACE: LOGO & "MITEL"
o WHITE
• INSTALL
• CENTER OVER WALKWAY
•
•
•
End View 0
Scale: 3/4" =1' 0"
EXISTING CONCRETE WALL
CAULK - GEOCEL 2300
AWNING TOP BAR
FABRIC
111111111111111it11111
3/16" THICK x 1" WIDE Z -BRACKET
(1 EVERY 24" O.C. - TOP BAR)
(1 EVERY 48" O.C. - BOTTOM BAR)
3/8"-16 UNC x 5" LONG
EXPANSION 4" DEEP
GI Concrete Attachment Detail 3
Scale: 6" =1 0
• MASTER • PROJECT MGR a SALES • DTS a FRAME / ASSEMBLY • FABRIC 0 GRAPHICS ♦ INSTALL • WOOD SHOP • SHIPPING e
Rlainierbidusbies, Ltd
18435 Olympic Ave. S.
Tukwila, WA 98188
800-869-7162 Toll Free
425-251-1800 Phone
425-251-5065 Fax
www.Rainier.com
Original design concepts are protected
under Federal Copyright Laws and
are the property of Rainier Industries, Ltd.
Any reproduction of this design concept
without written consent is expressly
forbidden.
ISO 9001:2000 REGISTERED
MITEL
14240 INTERURBAN AVE S
STE 170
TUKWILA WA98168
Revisions
RECEIVED
-S P 2 3 2008
COMMUNITY
DEVELOPMENT
WILLARD PARK
Sales Person
PEAK ROOF CANOPY
Job Name
CANOPY DETAILS
Drawing Title
124371
RI Work Order Number
TED S MARIER
Drawn By
ZAC ROGER / 8-20-08
Checked By / Date
DAVE TAQUINO
Project Manager
--/--
Issue Date / By
P3.00
Sheet Number
• •
.......:..........:..:.
OLUTIONS
CENTER
o
• •
PROPOSED NEW AWNING
1
7'-0"
//
7
//
Q)
4'-0"
SOLUTIONS•
CENTER
North Elevation View O West Elevation View South Elevation View
Scale. 3/8"11-0" Scale: 3/8"1 0 O Scale: 3/8"=1-0 O
File Name: P:1DTSIDEVELOPMENT\Mite11124369 - wedge awning1124369.dwg
RECEIVED
SEP 2 3 2008
COMMUNITY
DEVELOPMENT
Rainier Industries, Ltd
18435 Olympic Ave. S.
Tukwila, WA 98188
800-869-7162 Toll Free
425-251-1800 Phone
425-251-5065 Fax
www.Rainier.com
Original design concepts are protected
under Federal Copyright Laws and
are the property of Rainier Industries, Ltd.
Any reproduction of this design concept
without written consent is expressly
forbidden.
ISO 9001:2000 REGISTERED
MITEL
14240 INTERURBAN AVE S
SUITE 180
TUKWILA,WA98168
Revisions
WILLARD PARK
Sales Person
WEDGE AWNING
Job Name
ELEVATION VIEW
Drawing Title
124369
RI Work Order Number
TED S MARIER
Drawn By
ZAC ROGERS / 8-20-08
Checked By / Date
DAVE TAQUINO
S3t4effq
e MASTER a PROJECT MGR 0 SALES ♦ DTS a FRAME / ASSEMBLY a FABRIC a GRAPHICS • INSTALL a WOOD SHOP 0 SHIPPING a Sheet Number
Project Manager
--/—
Issue Date / By
P2.00