Loading...
HomeMy WebLinkAboutPermit S08-106 - VILLAGES AT SOUTH STATIONSECURITY PORPERTIES INC VILLAGES AT S STATION 3724 S 154T" LN S08-106 FREE STANDING SIGN SITE INSPECTION (PLANNING) File No. S08-106 Name of Tenant: The Villages at South Station Sign Address: 3724 S 154th Lane Date Photo Taken: July 13, 2009 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Signs inspected and final approval granted. CT 07-13-09 CityTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 0043000335 Address: 3724 S 154 LN TUKW Suite No: PERMANENT SIGN PERMIT Permit Number: S08-106 Issue Date: 03/06/2009 Permit Expires On: 09/02/2009 Business: Name: WEST COLONIAL VILLAGE (FORMERLY) Address: 3724 S154TH LANE , TUKWILA WA Property Owner: Name: SP TUKWILA L L C Address: 1201 3RD AVE STE 5400 Contact Person: Name: ANGELA LEVENDA Address: VERTICAL VISUAL SOLUTIONS Contractor: Name: VERTICAL VISUAL SOLUTIONS Address: 22833 BTHL-EVT HWY Phone: 866-832-4272 Phone: Phone: 206.551.8738 Phone: 206.551.8738 DESCRIPTION OF WORK: Replace existing freestanding sign with new sign in different location. Renaming from West Colonial Village to the Villages at South Station. Fees Collected: $125.00 PERMANENT SIGN: Zoning: HDR Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 0 0 0 0 Wall Sign Size (sq. feet): 0 0 0 0 Sign Lighting: Face Residential Land: Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 0 Building Height (feet): 0 0 Sign Size (sq. feet): 26.79 0 Sign Height (feet and inches): 4 ' 6 " 0 ' 0 " Setback (feet): 11.83 0 Number of Sign Faces: 2 0 Planning Division Authorized Signature: Tr l,t'�7 Date: 31 (V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S08-106 Printed: 03-06-2009 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 0043000335 Address: 3724 S 154 LN TUKW Suite No: Applicant: DPA SIGNS RECEIPT Permit Number: S08-106 Status: PENDING Applied Date: 11/10/2008 Issue Date: Receipt No.: R08-03718 Payment Amount: $125.00 Initials: SM Payment Date: 11/10/2008 10:56 AM User ID: 1166 Balance: $0.00 Payee: Kevin Wellbaum for DPA Signs TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1106 125.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts SIGN PERMIT 000/322.100 125.00 Total: $125.00 .)7 r .,.,,. . ,, i �_� � rt� rinr• Rarpint-(1R Pri ntarl : 11-1(1-7nnR Cif Tukwila DepWent of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 (206 431-3670 PERMIT ea)S- \ D 1'11 DATE: N t (�-106 Security Properties, Inc. P� Villages at south Station RBusiness Name x,106 lSecurity Properties, Inc. Applicant/Contact Contractor U �fi l V 15 Please print 3724 S. 154th Lane, Tukwila, WA 98188 Address of Sign 1201 Third Ave., Suite 5400, Seattle, WA 98101 Address, City, State, Zip 927 N. 128th Street, Seattle, WA 98133 ddes ,Ci Sate Li- ♦ 1 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $125 application fee per sign See back of form for examples 1,0 866-832-4272 Q Phone trw 200a 206-926-6149 Phone CON► 40E(TY UNI 206-362- Phone Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area LI Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: El $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). O Construction details to describe the proposed foundation or wall attachments (see back of form for examples) O Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? 0 Yes 0 No Wall WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) Sign size(square feet) Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. Does wall sign weigh more than 400 pounds?(Y/N) Sign illumination (internal/external/none) FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area � -7� 11) �/ P Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.i /,i /i �l� v Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. to /moi I) 10 Number of sign faces INSPECTIONS •1'6i O If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for foo ing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila will be met. 4lwel/ha et1, 45./9ns. *M (Signature of owner or authorized agent) Email Address Date FOR OFFICE USE ONLY Zoning: Planning review by: 0 Denied 0 Issued ❑ Issued with conditions Structural review required? 0 Yes 0 No Structural review by: • • Jaimie Reavis - Tukwila sign height calculation Page 1 of 1 From: Jaimie Reavis To: dminnick@verticalvs.com Date: 02/23/2009 11:32 AM Subject: Tukwila sign height calculation I'm sorry - the height calculation I mentioned over the phone is related to building construction. For signs, we refer to the definition of height in our sign code, which is included below: 19.08.100 Height "Height" means the distance measured from: 1. The lowest point of elevation of the ground between the top of the sign and a point five feet distant from said sign, or 2. The lowest point of elevation of the finished surface of the ground between the top of the sign and the property boundary, if it is less than five feet distant from said sign. file://C:\temp\XPGrpWise\49A28964tuk-mail63 00-po 100168626D 182C91 \GW } 00001.... 02/24/2009 42" 36" 2 1' diameter round, W tall aluminum stand-offs for Rain Visors (1" in from outer edges) 18.25- 0 I"I 0 0 0 0 PLAN VIEW 5" 9" 1" diameter round, `A" tall aluminum standoffs for Rain Visors (1" in from outer edges) 91.5" 89" 89" 1 /2"Aluminum dimensional letters Flush mounted surface of cabinet. A" Aluminum Rain Visors with 1" diameter round aluminum standoffs 45.5" 43" -- J 1" X 4" Rectangle -tube Aluminum, mitered and end capped, then attached to the outside of the cabinet with hardware as required. 3/8" SS bolt/washer/nut Trough -bolt with mounting plates welded to both square -tube structures. Cap Stone Owens Coming: 12" x 20" Flagstone Wall Cap Champagne AS -1200 12" 30" 18" Grade 108" 112" 5"x45.5"x.5" Aluminum Plate 11"x 91.5" x .5" Aluminum Plate Average grade 8" deep 12" deep 8" 3" VERTICAL PM/3 1203 22833 BTHL-EVT HWY SUITE 110 BOTHELL, WA. 98021 VISUAISOLOTIONS www.vefdQlvs.com MEW The Villages Security Properties Tukwila, WA APPROVAL Client Use Only ❑ Approved ❑ Approved w/ Comments ❑ Resubmit PROJECT Date Wayfinding signs Signature Printed Name Job # Issue Date: 1/20/09 Designer / Minnick Check By @ Date. PAGE 1 Double -Face Aluminum cabinet(s) and attached elements with intemal square -tube frame. 42" 36" 1" diameter round, W tall aluminum stand-offs for Rain Visors (1' in from outer edges) PLAN VIEW 5" 9" 4" 18.25" O I V 19.75' 0 0 0 0 1" diameter round, 'A" tall aluminum stand-offs for Rain Visors (1" in from outer edges) 91.5" 0 0 89" 89" 45.5" 43" 3 -5g3 W Aluminum Rain Visors with 1" diameter round aluminum stand-offs 1/4" Aluminum Dimensional Letters Flush -mount to surface of cabinet the vEl[lages Stat: 1" X 4" Rectangle -tube Aluminum, mitered and end capped, then attached to the outside of the cabinet with hardware as required. 3/8" SS bolt/washer/nut Trough -bolt with mounting plates welded to both square -tube structures. 0,-4004 & j n e.a_ Q. (1 ° w = 32 -F-t multi - farm ((j de_vetopm�' 39 -�-d s7) 63 r, 31(p 1001 5"x45.5"x.5" Aluminum Plate 11"x91.5"x .5" Aluminum Plate Cap Stone Owens Coming: 12" x 20" Flagstone Wall Cap Champagne AS -1200 12" 30" 18" Grade 108" 112" Average grade 8" deep 8" 3" e 12" deep EF) VERTICAL VISUAL SOLUTIONS PMO 1203 22033 BTHL-EVT NWT SUITE 110 BOTHELL. WA. 98@1 www.verticalvs.com The Villages Security Properties Tukwila, WA APPROVAL Client Use Only ❑ Approved ❑ Approved w/ Comments ❑ Resubmit Date Signature Printed Name PROJECT Wayfinding signs Job # Issue Date: 1/20/09 Designer / Minnick Check By & Date' PAGE 1; 114 St. DRIVE ENTRY ;9, .•• • o 44 444 44‘. • • • •s SIGHT .. • ssTRIANGLEy R • NeI a MONUMENT SIGNAY'iE 4'-8" (HT.) X 8'-3" (LENGTH) ENTRY MONUMENT PLAN roperty i?Qiiflda , 8'-4" I • • • • * • •• •• • • • •• •• •• A Scale: 3/16" = 1'-0 w (1•0 ISD INTEGRATED SITE DESIGN LANDSCAPE ARCHITECTS PLANNING, DESIGN 12743 26th Avenue NE Seattle, WA 98125 (206) 363-9049 FAX 362-6460 PROJECT: Villages at South Station 3724 South 154th Lane Tukwila, WA CLIENT: Secutity Properties Seattle, WA REVISIONS: February 9, 2009 CLIENT APPROVAL Schematic Design Development Permit Documents Bid Documents Construction Documents • ENTRY MONUMENT PLAN SHEET NO. SK -2 PROJECT NO. May not be reproduced without permission of designer.