Loading...
HomeMy WebLinkAboutPermit S09-020 - CHASECHASE 359 STRANDER BLVD S09-020 FREE STANDING SIGN SITE INSPECTION (PLANNING) File No. S09-020 Name of Tenant: Chase Sign Address: 359 Strander Blvd. Date Photo Taken: June 5, 2009 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and final approval granted. CT 06-05-09 Parcel No.: Address: Suite No: City ( ' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us 2623049064 359 STRANDER BL TUKW PERMANENT SIGN PERMIT Permit Number: Issue Date: Permit Expires On: S09-020 04/10/2009 10/07/2009 Business: Name: Address: Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: CHASE 359 STRANDER BLVD , TUKWILA WA REGENCY CENTERS LP C/O PROPERTY TAX DEPT CONNIE GUFFEY 909 S 28TH ST PLUMB SIGNS 909 S 28TH ST Phone: Phone: Phone: 253-473-3323 x10 Phone: 253 473-3323 DESCRIPTION OF WORK: ONE WALL SIGN AND ONE FREESTANDING SIGN FOR "CHASE". Fees Collected: PERMANENT SIGN: Wall Area (sq. feet): Wall Sign Size (sq. feet): Sign Lighting: Face Residential Land: $260.00 Zoning: TUC Sign Type: Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Sign Lighting: Wall Sign #1 632.15 29.76 internal N Wall Sign #2 0 0 N Freestanding Sign #1 500 0 17.48 0' 0" 0 2 internal Wall Sign #3 0 0 N Freestanding Sign #2 0 0 0 0'0" 0 0 N Wall Sign #4 0 0 N Planning Division Authorized Signature: Date: �f C' c-? [ hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. =, FINAL INSPECTION APPROVAL: DATE: doc: SIGN -PERM nA.A n_9nno S09-020 Panted: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049064 Permit Number: S09-020 Address: 359 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 04/03/2009 Applicant: CONNIE GUFFEY Issue Date: Receipt No.: R09-00526 Initials: User ID: SM 0400 Payment Amount: $260.00 Payment Date: 04/03/2009 02:07 PM Balance: $0.00 Payee: CONNIE GUFFEY FOR PLUMB SIGNS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 043638 ACCOUNT ITEM LIST: Description 260.00 Account Code Current Pmts SIGN PERMIT 000/322.100 260.00 Total: $260.00 rinr• Parcinf-nR Printed: 04-03-2009 • LICENSED AB;j:PROYIDBD.BY LAW AS ELEC SIGN. • : LICENSE '# ' EXP. BC04i:PLUMBSI077QS :11/10/2009 , .11/10/199.3 . . PLUMB SIGNS'...; 909 S 28TH sT.:.-, TACOMA ,WA..;7;:7-9 • Signature cf R. . - Issued- by DEPARTMENT OP .LABOR A WA ,,,,,,,,,, 0% City 4Tukwila PE. NO. SCP\ —020 De artmOi of CommunityDevelopment �. 6300 Southcenter Boulevard, Suite 100 DATE: (f 3icct RECEIVED Tukwila, Washington 98188 APR 0 3 2009 206 431-3670 CHASE Business Name Connie Guffey Applicant/Contact Plumb Signs Inc. Contractor Please print 359 Strander Blvd Address of Sign 909 S. 28th.St., Tacoma, 98409 Address, City, State, Zip 909 S. 28th St., Tacoma, 98409 (253)473-3323 Phone (253)473-3323x10 Phone Address, City, State, Zip Phone CHECKLIST EA 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license See attached fee schedule for application fee See back of form for examples Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? 0 Yes 0 No Wall 1 WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) EO 1 823 1 4 A\ Sign slze(square feet) 36.12 Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. No N o Does wall sign weigh more than 400 pounds?(Y/N) No N o Sign illumination (internal/external/none) I n t I n t FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Face Change E 0 2 D i r e c t i < 06/N09 Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area 17.4 8 1\ 89 Sign height (feet -Inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of si, n faces INSPECTIONS 2 2 If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete Is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the Electrical Permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila w' be met. 4/3/09 Date Signature of owner or au td ag=,er connie@plumbsigns.com Email Address FOR OFFICE USE ONLY Zoning: Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions na site; . , ; CI-4‘NC? 30 i LiKwil a .. , p.olkosite silo EC1 i I , E02 ! 2..1 , EC13 ', 37 1 i A1111 111 NC91-'-':--1-1-.s. i --T— —4- ..... : , ! - Re'ac .11 Dyi,,-..n '!e,-.ar.it D. n,-:,Ic. DOT CJST r_ --.1q--11-1; — - • D i t-, 0 A/4-4- ATV Etc,nii.J...-.. Canop,' --- Kyr Is, iA-JOit-g- -/ '4" - 7 CHASE 0 Virtua Tr'4 lelor e. 0 11,41... Os tRE ivED PR 0 3 NOT LO!- OF--H-W130-24-s - 24" Cap H. Hum, Chrl Lirs on Hace,Atay (140;ht) Deievr-vne a raceway can be nstal'ed belinc) FrcpcseC • l• DF:632.15# al Allowed z 3o 2.11`r sc9,2 -1,4> Silent zq:10 1—‘ gi . ....,...t. ,t. „.,..... .... t,.......„„, „,,,.., ,. .t"...„4.ttT;,].',::',.:.4-t-!.4...*4-s.fitItt'o-,,,,,".".-'4,-'-',:iii,:itp-t..444:1,16.,..;,4,-ti!T S g, 7-3 7 x LL AREA — WEST ELEVATION: N AREA —WEST ELEVATION: • ED Nc t RECEIVED APR 0 3 201),J COMMUNITY DEVELOPMENT Patch and repaa existiny wall surface to like new condition t. bri.:k or stone walls flit ht".cs wttr. matching 514:. or* RepiEntto match exist' (040- tints* PCWer wash A'1111 required Phila Sign 12.C.3 130 JD E02 - FAeface €f/f pylon tenant panes Not to, Scat.? Philadelphia S gn Chase _+:ct•:t:c� a 1 ii raZ;a. z•. S:gn Dint=ns}ans: 28 x 90 1,12" • ,y. f ECE VE. APR 0 3 2009 COMMUNITY D T •„,; N. 1 •;i�'r:_r n _ ATM 1- SUA-TTWt-U - Universal TTViW Surround 010'09 14 4f riovito 4,4 Proposed RECEEWED 'APR 0 3 2009 COMMUNITY DEVELOPMENT • lir�.�a;t Philadelphia ,Z .,._,. , „• . n (;base C....: I: 12.03.03 • 1' 3 'o til ... :,:..1,1 :0 14 r_t-z 7 t:.: .• S. -' rr S.,..-_,. c^ .]a St. 4=rr:::_•.........7.:. ` ! ' _ eTIlr. t..H.'.t,t;i:) y.t:t kte,� it;l,:tpaa,' +at 371 I i :. h,t't a•� n O c }rc..nt is - DOT. GUST (Right Turn Oily) • N09 TC -P -H -s - 1'- I 3/4"w x 11-9 h x 6'-9 'oat) Non litum. Pole Mntd Regulatory (Mount back to back with E06 on exostgng pole painted Chase blue) Proposed EU; 1 Er RIGHT TURN ONLY DOT Right Turn 031ly 41° 0210 Philadelphia Sign Chase • 1 i•ZI War:. Proposed N09 TC -P -H -s A i9 i.e.l_c_-7-76A/ 12.0108 4 ZIG 9C-6 &P-C2'6r— . . „ C.. Er.ir:.0 APR 0 3 2009 COMMUNiTY DEVELOPMENT r „ ; • :Jr e, • 4 1/4" • 2'-0" 7, / 1 / r , 1,_ \_ /A /A\> ----) r sign= Nilo LIF-WBO-24(60ma) NEON LIT CHANNEL LETTERS (White Letters / Blue Octagon) SCALE: N.T.S. 1 3/4" 7 3/4" 2 1/4" --- 5" SIDE VIEW AT LETTER SIDE VIEW AT SYMBOL SCALE: N.T.S. I SCALE: N.T.S. STANDARD LETTER NOTES: 1. Sufficient Primary Circuit In Vicinity Of Sign By Others. 2. Letter To Letter Wiring & Final Primary Hook-up By Sign Installer, Where Allowed By Local Codes. 3. Sign Shall Be U.L. Listed. 4. Mounting Hardware By Sign Installer. 5. Full Size Drilling Template Furnished With Sign. 6. This Sign has been Designed with the Criteria as set forth in the IBC 2003 & IBC 2006. The Design Meets or Exceeds those Requirements for the Geographical Location in Which it is to be Erected. PEWITS WIN (60ma) ELECTRICAL LOAD 3.6 AMPS @ 120 VOLTS ELECTRICAL REQUIREMENTS (1) 20 AMP / 120 VOLT CIRCUIT Note: This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. GENERAL NOTES: CHASE SIGNATUI.NS • ALL PAINTS TO BE TWO-PART POLY -URETHANE BY MATHEWS. GLOSS FINISH. • ALL FILM TO BE 3M UNLESS OTHERWISE STATED. • ALL STEEL COMPONENTS TO BE PRIMED WITH ZINC INHIBITOR (DEVCON-Z OR APPROVED EQUAL). • ALL STRUCTURAL COMPONENTS TO BE SIZED BY A LICENSED STRUCTURAL ENGINEER TO MEET OR EXCEED ALL LOCAL, STATE, AND NATIONAL CODES. • ALL ELECTRICAL WORK TO MEET OR EXCEED U.L. REQUIREMENTS. • ALL EXPOSED FASTENERS TO BE PAINTED TO MATCH CABINET. • ELECTRICAL LEADS FROM THE BACK OF ILLUMINATED LETTERS TO BEA MINIMUM OF 6' -0" LONG AS MEASURED FROM THE BACK OF THE LETTER. MATERIAL SPECIFICATIONS: PAINT: • CHASE BLUE - MATHEWS MP -00366 • CHASE BLUE METALLIC - MATHEWS MP -49353 • CHASE ATM NICKEL - MATHEWS MP -18101 • CHASE NICKEL - MATHEWS MP -19891 • CHASE DK NICKEL - MATHEWS MP -18248 VINYLS: • CHASE BLUE - 3M 3632-127 • CHASE LT BLUE FILM - 3M 3630-147 • WHITE OPAQUE - 3M 7725-10 • WHITE TRANSLUCENT - 3M 3632-20 • WHITE REFLECTIVE - 3M 680-10 • WHITE DIFFUSER - 3M 3635-70 ACRYLIC: • WHITE -ARISTECH 7328 • CLEAR ACRYLIC • BLUE -ARISTECH 6046 • BLACK / WHITE - ATOGLAS #3063 P95m VERTICAL SECTION - OCTAGON NOT TO SCALE VERTICAL SECTION - LETTERS NOT TO SCALE NOTES: 1. 3/16"ARISTECH 7328 TRANSLUCENT MATTE FINISH WHITE ACRYLIC FACE CHEMICALLY BONDED TO ACRYLIC RETURNS TYP. 2. .125" ARISTECH 6046 TRANSLUCENT BLUE ACRYLIC RETURN WITH SECOND SURFACE APPLIED 3M 43635-70 DIFFUSER FILM CHEM. CHEMICALLY BONDED TO ACRYLIC FACE TYP. ATTACH RETURNS TO BACK WITH CNTR SUNK FLAT HEAD STAINLESS STEEL SCREWS. PAINT HEADS TO MATCH LETTER BACK RETURNS. 3. .090" ALUM. LETTER BACK WITH RETURN. FORM AS SHOWN. PAINT FINISH ALL EXTERIOR SURFACES TO MATCH MATTHEWS MP -00368 CHASE BLUE, SEMI -GLOSS. PAINT FINISH ALL INTERIOR SUFACES WITH SPRAY -LAT STAR BRIGHT WHITE LIGHT ENCHANCEMENT PAINT. 4. .090" FORMED ALUM. ATTACHMENT CLIPS INTERMITTENT AT INSIDE PARAMITER. 5. 15mm WHITE NEON TUBE(S). NEON TO BE 6500K. 6. NEON TUBE SUPPORTS. 7. TRANSFORMERS: (2) VENTEX 6,000V/60ma@ 1.80A BASED ON INDUSTRY STANDARDS PER LINEAR FOOTAGE OF TUBE REQUIRED. 8. ELCTROBITS ELECTRODE BOOT AS REQUIRED TO MAKE CONNECTION BETWEEN ELECTRODE AND GTO CABLE. 9. ELECTROBITS GTO FLEX CABLE. 10. ELECTROBITS PASS THROUGH AS REQUIRED. 11. ELECTROBITS HVC HIGH VOLTAGE CONNECTOR FOR DRY LOCATIONS. USE ELECTRICAL GANG BOX WHEN REQUIRED FOR DAMP LOCATIONS. 12. ELECTROBITS GROUNDING RING AND GROUND WIRE. 13. PROVIDE WEEP HOLES TO MEET U.L. REQUIREMENTS. 14. 3/8" DIAMETER NON -CORROSIVE MOUNTING HARDWARE AND DOUBLE EXPANSION ANCHOR IN A SOLID BRICK MASONRY WALL (MIN. 4 PER LETTER) 15. ''A" DIAM SPACER 16. NOT USED 17. NOT USED 18. OCTAGON FACE TO BE THERMO-FORMED .125" BLUE ARISHTECH 6046 TRANSLUCENT ACRYLIC.. CHEM WELD TO 3/4" CLEARACRYLIC SPACER SECOND SURFACE. 19. 3/4" CLEAR ACRYLIC SPACER. SHOULDER CUT AS SHOWN. LEAVE A 1/8" FLANGE AT FRONT. HOLD RETURNS IN 1/8" FROM PERIMETER. (NOTE: SPACER CAN 6E 1/2" CLEAR ACRYLIC FOR LARGER LETTER SETS TO REDUCE WEIGHT). 20..090" ALUM. RETURNS. FORM AS SHOWN. PAINT FINISH EXTERIOR NICKEL. GLOSS FINISH. PAINT FINISH ALL INTERIOR SURFACES WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENCHANCEMENT PAINT. 21. PROVIDE 1/8"x 1/2" NEOPRENE STRIP AT PERIMETER OF LETTER TO PREVENT LIGHT LEAKS FROM EXPANSION/CONTRACTION. Philadelphia Sign C o M P A N Y 707 West Spring Garden Street Palmyra, New Jersey 08065 Phone 856 8291460 Far 856 829 8549 E-ntaU mm7®philadelphiaai8n.rom CHASE C REVISIONS Date: Deadpan: BY DRAWING TYPE: PERMIT DRAWING SIGN TYPE: LIF-WBO-24 - 60ma NEON CHANNEL LETTERS LOCATION: VARIOUS DATE: , 03-11-09 RECEIVED FAPR 0 3 2009 COMMUt r ( OCt (WP EVELOPStIE T DRAWN BY: WMH SHEET: 1 of 1 DWG NUMBER: B-33050 THIS IS AN ORIGINAL UNPUBUSHED DRAWING CREATED BY P.S.C.O. fr IS SUBMITTED FOR YOUR PERSONAL USE IN CONJUNCTION WITH A PROJECT BEING PLANNED FOR YOU BY P.S.C.O. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS R TO BE USED, COPIED, REPRODUCED, OR EXHIBITED IN ANY FASHION. • 3' 5 V2' .125' ALIA x I I/2' WIDE BRACE WITH 1/16' DIA HOLE FOR RACEWAY tiCtN1110 FASTENER (5 REQ'D) ;r le e NOTES: WHITE CHANNEL LETTERS J 1/16' DIA HOLE TO NOWT LETTER TO WALL (2 PER LETTER REQ'D) 1..125 ARISTECH 7328 TRANSLUCENT MATTE FINISH WHITE ACRYLIC FACE CHEMICALLY BONDED TO ACRYLIC RETURNS TYP 2..125° ARISTECH 6046 TRANSLUCENT BLUE ACRYLIC RETURN CHEMICALLY BONDED TO ACRYLIC FACE TYP. 3. .090 ALUM. BACK 4. 15mm EGL CL DESIGNER 71 WHITE NEON TUBING 5. 3/8' DIA. A36 THREADED ROD WITH NUT, FLAT & LOCK WASHERS INTO DOUBLE EXPANSION ANCHOR IN SOLID BRICK MASONRY WALL. 6. INDIA. PIPE SPACER FROM BACK OF LETTER TO FACE OF BLOCKING. PAINT TO MATCH EXISTING BUILDING. 7. 1/4" DIA. DRAIN HOLE TYP. 8. PAINT EXTERIOR OF ALUM. RACEWAY AND ENDCAPS TO MATCH EXISTING BLDG. 9. PAINT EXTERIOR OF ALUM. LTTR. RETURNS TO MATCH MATTHEWS MP -00366 CHASE BLUE, SEMI -GLOSS 10..125 THERMO-FORMED ARISTECH 6046 TRANS- LUCENT BLUE ACRYLIC WEDGE FACE TYP. 11. 3/4" CLEAR ACRYLIC FACE CHEMICALLY BONDED TO WEDGE FACE 12. PAINT EXTERIOR OF OCTAGON RETURNS & BACK TO MATCH MATTHEWS MP -19891 CHASE NICKEL, GLOSS 13. 3/8" DIA. NON -CORROSIVE MOUNTING HARDWARE & DOUBLE EXPANSION ANCHOR IN SOLID BRICK MASONRY WALL. (5 REQ'D PER RACEWAY) 14. FORMED .050 ALUM. DRAIN HOLE COVER TYP. 14. POWER SUPPLY IN RACEWAY TYP. 10 8 V4' 3'-5 V2' 14' 0 V2' 3'-5 1/2' 1/16' DIA. HOLE TO NOWT LETTER TO RACEWAY ' (2 PER LETTER REQ'D) 8 3/4' 2'-1 V2' 3'-5 I/2' LJ L8 ELEVATION & MOUNTING LOCATIONS LIF-R-WBO-24 60ma (WHITE LETTERS/BLUE OCTAGON) - NEON SECTIONS FOR BRICK WALL INSTALLATION Note: This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. • DISCONNECT SWITCH PIOUS UNIY ELECTRICAL LOAD' 3.6 AMPS @ 120 VOLTS ELECTRICAL REQ'MTS (1) 20 AMP CIRCUIT / 120 VOLTS GENERAL NOTES: CHASE SIGNATURE SIGNS • ALL PAINTS TO BE TWO-PART POLY -URETHANE BY MATHEWS. GLOSS FINISH. • ALL FILM TO BE 3M UNLESS OTHERWISE STATED. • ALL STEEL COMPONENTS TO BE PRIMED WITH ZINC INHIBITOR (DEVCON-Z OR APPROVED EQUAL). • ALL STRUCTURAL COMPONENTS TO BE SIZED BY A LICENSED STRUCTURAL ENGINEER TO MEET OR EXCEED ALL LOCAL, STATE, AND NATIONAL CODES. • ALL ELECTRICAL WORK TO MEET OR EXCEED U.L. REQUIREMENTS. • ALL EXPOSED FASTENERS TO BE PAINTED TO MATCH CABINET. • ELECTRICAL LEADS FROM THE BACK OF ILLUMINATED LETTERS TO BE A MINIMUM OF 6' -0" LONG AS MEASURED FROM THE BACK OF THE LETTER. MATERIAL SPECIFICATIONS: PAINT: • CHASE BLUE - MATHEWS MP -00366 • CHASE BLUE METALLIC - MATHEWS MP -49353 • CHASE ATM NICKEL - MATHEWS MP -18101 • CHASE NICKEL- MATHEWS MP -19891 • CHASE DK NICKEL- MATHEWS MP -18248 VINYLS: • CHASE BLUE - 3M 3632-127 • CHASE LT BLUE FILM - 3M 3630-147 • WHITE OPAQUE - 3M 7725-10 • WHITE TRANSLUCENT - 3M 3632-20 • WHITE REFLECTIVE - 3M 680-10 • WHITE DIFFUSER - 3M 3635-70 ACRYLIC: • WHITE - ARISTECH 7328 • CLEAR ACRYLIC • BLUE -ARISTECH 6046 • BLACK / WHITE - ATOGLAS #3063 P95m Philadelphia Sign A N Y C 0 M 707 West Spring Garden Street Palmyra, New Jersey 08065 PBonc 856 8291460 Far 856 829 8549• Emma: mm1®Fhfladelphia4 gn.com CUSTOMER: CHASE JOB NUMBER: REVISIONS: Ode: Deealplbrc 2-24-09 REVISED NOTES BY WMH DRAWING TYPE: PERMITS SIGN TYPE: 60ma NEON RNV LTRS LIF-R-WBO-24 LOCATION: VARIOUS DATE: 01-29-09 STANDARD LETTER NOTES: 1. Sufficient Primary Circuit In Vicinity Of Sign By Others. 2. Letter To Letter Wiring & Final Primary Hook-up By Sign Installer, Where Allowed By Local Codes. 3. Sign Shall Be U.L. Listed. 4. Mounting Hardware By Sign Installer. RECEIVE() 5. Full Size Drilling Template Furnished With Sign. 6. This Sign has been Designed with the Criteria APR 0 3 as set forth in the IBC 2003 & IBC 2006. The f 2009 Design Meets or Exceeds those Requirements for the Geographical Location in 't is DCOMMUNw be Erected. en2 DRAWN BY: WMH SHEET: 1 of 1 DWG NUMBER: B-30875 THIS IS AN ORIGINAL UNPUBUSHED DRAWING CREATED BY P.S.C.O. R IS SUBMITTED FOR YOUR PERSONAL USE IN CONJUNCTION WITH A PROJECT BEING PLANNED FOR YOU BY P.SCO. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, COPIED, REPRODUCED, OR EXHIBITED IN ANY FASHION.