HomeMy WebLinkAboutPermit S09-043 - SUBWAYSUBWAY
7100 FUN CENTER WAY #150
S09-043
BUILDING MOUNTED
SIGN
SITE INSPECTION (PLANNING)
File No. S09-043
Name of Tenant: Subway
Sign Address: 7100 Fun Center Way #180
Date Photo Taken: November 16, 2009
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of XX/XX/200X
Make new site visit and take photo by XX/XX/200X
Comments: Sign inspected and final approval granted. CT 11-16-09
City of/Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.citukwila.wa.us
Parcel No.: 2423049092
Address: 7100 FUN CENTER WY TUKW
Suite No:
PERMANENT SIGN PERMIT
Permit Number: S09-043
Issue Date: 10/23/2009
Permit Expires On: 04/21/2010
Business:
Name: SUBWAY
Address: 7100 FUN CENTER WAY #150 ,
Phone: 206-779-0909
Property Owner:
Name: H2 OFFICE LLC Phone:
Address: 7100 FUN CENTER WAY STE 100
Contact Person:
Name: CONNIE GUFFEY Phone: 253-473-3323 X10
Address: 909 S 28TH ST
Contractor:
Name: PLUMB SIGNS Phone: 253-473-3323
Address: 909 S 28TH ST
DESCRIPTION OF WORK:
Fees Collected: $130.00 Zoning: C/LI Sign Type:
PERMANENT SIGN:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 625 0 0 0
Wall Sign Size (sq. feet): 29 0 0 0
Sign Lighting: INTERNAL N N N
Face Residential Land: N
Freestanding Sign #1
Street Frontage for Entire Lot: 0
Building Height (feet): 0
Sign Size (sq. feet): 0
Sign Height (feet and inches): 0 ' 0 "
Setback (feet):
Number of Sign Faces:
Sign Lighting:
0
0
N
Freestanding Sign #2
0
0
0
0' 0"
0
0
N
Planning Division Authorized Signature:
J1J!/d0
Date: (0/ 23/C311
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510
for sign final inspection. Please allow up to 5 business days for your inspectionj
FINAL INSPECTION APPROVAL: DATE:
doc: SIGN -PERM
1 n_71_7nnQ
S09-043
Printed:
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 2423049092
Address: 7100 FUN CENTER WY TUKW
Suite No:
Applicant: PLUMB SIGNS
RECEIPT
Permit Number: S09-043
Status: PENDING
Applied Date: 10/23/2009
Issue Date:
Receipt No.: R09-01669
Initials:
User ID:
CT
0400
Payment Amount: $130.00
Payment Date: 10/23/2009 10:12 AM
Balance: $0.00
Payee: Garry Moe for Plumb Signs
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 17493 130.00
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
SIGN PERMIT
000.322.100 130.00
Total: $130.00
dnn• Receint-06 Printed: 10-23-2009
City of ukwlla PERM 0. °(+ 3
Departme Community Development 1
6300 Southcenter Boulevard, Suite 100 DATE: 0 2 3
Tukwila, Washington 98188
206 431-3670
PERMANENT SIGN PERMIT APPLICATION
SUBWAY
Business Name
Connie Guffey/Plumb Signs 909 S. 28th St., Tacoma, 98409 253.473.3323 x10
Applicant/Contact
Plumb Signs Inc.
Please print
7100 Fun Center Way #150
Address of Sign
20$ho e 9 0909
Contractor
Address, City, State, Zip
Phone
909 S. 28th St., Tacoma, 98409 253.473.3323
Address, City, State, Zip
Phone
CHECKLIST
fg
r.
•%
3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
Sign elevations with area calculations and dimensions
Building elevations (for wall signs)
Supporting structure and method of illumination
One copy of valid Washington State contractor's license
See attached fee schedule for application fee
See back of form for examples
Is your sign a:
❑ Freestanding sign 15 or more feet in height
❑ Pole sign with face 30 square feet or more in aea
❑ Wall sign weighing 400 pounds or more 0
If any of the above are true, the application mu
through structural review. -DZ Ccs
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is co
rn
rn
rn
greater, you will be billed when you pick up your permit).
❑r Construction details to describe the proposed foundation or
wall attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding Wall 1
Did building go through design review? 0 Yes 0 No
WALL SIGNS:
#1
#2
#3
#4
Wall area (length x height) of the tenant space where the
sign will be mounted? (square feet)
5 7 5
Sign slze(square feet)
30
Does sign face residential zones or public facilities? (Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
1/O
Does wall sign weigh more than 400 pounds?(Y/N)
/J/D
Sign illumination (Intemal/extemal/none)
/,vr
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
Size of sign face (square feet). Structural review is required for pole signs with faces 30 square
feet or more in area
Sign height (feet -Inches). Structural review is requir4' for signs 15 feet or more in height.
Distance from closest edge of sign to property lines (feet). Generally, signs must be set
back from all properly lines a distance equal to their height.
Number of si • n faces
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the Electrical Permit and inspections from the City of Tukwila Permit Center at
(206) 431-3670.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
1 HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that
the applicable requirements of the City of Tukwila •e met.
/o "R3.69
Date
/
(Signature of owner or auth
ent)
connie@plumbsigns.com
Email Address
FOR OFFICE USE ONLY
Zoning: Planning review by:
O Denied
0 Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No Structural review by:
O Denied 0 Approved 0 Approved with conditions
PLUMB SIGNS
INCORPOR AT ED
909 SOUTH 28th ST. TACOMA, WA 98409
(253) 473-3323 FAX (253) 472-3107
PWMBSIGNS.COM
We -
JOB NAME
FILE NAME
LOCATION
START DATE ,
Subway Tukwila
SALES
5673 Subway Tukwila
DESIGNER
Warren Wissmer
Mike Lee
REV
DATE
7100 Fun Center Way Tukwila, WA
SCALE
10.20.09
PAGE
2 of 2
APPROVED BY: DATE
X
SIGNATURE
NoteColors on drawing may not
ac •cts • 'tied colors
A
1
3
SIC4.
t_upyright, 2009 Plurnb Signs, Inc.
This is an original design by Plumb Signs and
remains the property of Plumb Signs until
transfer by sale. An rights reserved. Any
unauthorized distribution or duplication
(electronic or other( results in a $1000 charge.
!eta verify all dimensions and conditions before fabrication •
CE I c'6.1
Internally Illuminated Channel Letters On Raceway 30 SF
'Scale: 3/4° =1'
Fabricate & install one (1) set of internally illuminated channel letters
mounted on raceway. Sign bears UL label.
Faces:
•.126 acrylic "SUB" is #7328 white plex
•.126 acrylic "WAY" is #2307 yellow plex
•1" Black Jewelite trimcap
•Illuminated by 13mm Cool White neon (7500) utilizing 30 MA
transformers
Letter Construction:
•5", .040 pre -finished Black returns and .063 Ietterbacks
•Insides painted with conversion coating and exterior white acrylic
enamel
•Weep/drain holes per UL specs
Raceway:
•Dimensions: 11 %" x 11' 1"
•Paint raceway: COLOR TBD
3/16'Acrylic
Face with 1'
Trim Cap,
Attached to
Channel Letters
with 1/4", Seif-
Tapping Screws;
5' Retum-
Aluminum
Channel
Letter,
Neon Tube
Secured with
Glass Stands
Channel Letter Attached
to Attached to Racewa/
with 1/4", Sef-Tapping
Screws
3/8" Lag Bolt
Fastener,
UL Approved
GTO insulated
Wire
Transformer
Enclosed in
Approved
Raceway
Existing
Wall &
Structural
Support
‘01
LETTER & RACEWAY ATTACHMENT/CONSTRUCTION DETAIL
:ihco
Custom size letter set - Scale 1/2"=1=0"
12'-6 "
11'-1 "
ESC- _ -Jr:7
si`gn Clea Ci (0WC = 2r1 r
s)Orl = a
eet)/
r
WALL AREA — FRONT ELEVATION:
25' X 25' = 625 SQ. FT. = 30 SQ. FT. ALLOWED
SIGN AREA —FRONT ELEVATION:
SUBWAY:
2'4" X 12"5 = 29.12 SQ. FT. PROPOSED
front elevation - 3/16" = 1'
tenant
PLUMB SIGNS ``'
INCORPORATED-
SOUTH 28th ST. TACOMA, WA 98409
(253) 473-3323 FAX (253) 472-3107
PLUMBSIGNS.COM
JOB NAME
Subway
SALES
Warren Wismar
REV
DATE
FILE NAME
Subway Tukwila
5673 Tukwila
DESIGNER
Mike Lee
APPROVED BY:
X909
DATE
LOCATION
7100 Fun Center Way Tukwila, WA
SCALE
1/2" = 1'
SIGNATURE
Note• Colors on drawint tufty rstrt
atx d: 'frciedmbn
START DATE
10.20.09
PAGE
1 of 2
SIC A,
Copyright, 2009 Plumb Signs, Inc.
his is an original design by Plumb Signs and
°mains the property of Plumb Signs until C (�
ransfer by sale. All rights reserved. Any }/
nauthorized distribution or duplication
electronic or other) results in a .51.000 charge.
"Field verify 311 dimensions and concltbns before fabrlcaticn