HomeMy WebLinkAboutPermit S10-021 - GOLFTECGOLFTEC 406 BAKER BLVD STE 2 SI 0-021 BUILDING MOUNTED SIGN SITE INSPECTION (PLANNING) File No. S10-021 Name of Tenant: GolfTec Sign Address: 406 Baker Blvd. #2 Date Photo Taken: September 8, 2010 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and final approval granted. CT 09-08-2010 City oil/Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 0223100037 Permit Number: S10-021 Address: 406 BAKER BL TUKW Issue Date: 04/15/2010 Suite No: # Z Permit Expires On: 10/12/2010 Business: Name: GOLFTEC Address: 406 BAKER BLVD #2 , TUKWILA WA Property Owner: Name: VILLAGE PARTNERS SOUTHCENTE Address: 1420 5TH AVE #2200 Contact Person: Name: SIGNS PLUS Address: 1330 N FOREST ST Contractor: Name: SIGNS PLUS Address: 1330 N FOREST ST Phone: 206-892-2172 Phone: Phone: 360-671-7165 Phone: 360-671-7165 DESCRIPTION OF WORK: 23.4 SQ. FT. WALL SIGN ON 520 SQ. FT. WALL WITH INTERNAL LIGHTING "GOLFTEC" AND PLACEMENT OF PANEL ON FREE STANDING SIGN "GOLFTEC". Fees Collected: $270.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 520 0 0 0 Wall Sign Size (sq. feet): 23.4 0 0 0 Sign Lighting: internal N N N Face Residential Land: N Freestanding Sign #1 Street Frontage for Entire Lot: 152 Building Height (feet): 25 Sign Size (sq. feet): 48 Sign Height (feet and inches): 19 ' 0 " Setback (feet): 21.5 Number of Sign Faces: 2 Sign Lighting: internal Freestanding Sign #2 0 0 0 0' 0" 0 0 N Planning Division Authorized Signature: Date: "[ —15— I 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. To acedule' `a fi_ a_Iii►s'"° erectono:y� o ugxiipleaseeiisp o�nA`trexqueste3ine ath206�-431`E�451 te�r2ispecti„o ode 1 S10 oar si2fihal inspection. lease''aliowpitorSbns‘ess,d fos panrLu�soection'., FINAL INSPECTION APPROVAL: DATE: doc: SIGN -PERM n4-1 F -7n1 n SI0-021 Printed: • 4°6 LZ6- 0(09 BAKER RETAIL STORES - SIGN CRITERIA These criteria have been established for the purpose of controlling the size, type, design and location of all signage, so as to enhance the centers image and create a mutual benefit to all Tenants. Conformance will be strictly enforced, and any installed non -conforming or unapproved signs must be brought into conformance at the expense of Tenant. 1. Administration a. All tenants shall provide fascia signage in accordance with thesecriteria. b. Tenant shall submit to the Landlord's Agent, three (3) prints of detailed drawings showing location of the sign on the storefront or designated space, size, layout, and color of the proposed sign, including all lettering and/or graphics, materials, attachment devices, construction and fabrication details. Tenant shall receive a copy of the sign. drawing approved with signature by the Landlord or Landlord's Agent prior to fabrication and installation. c. Tenant's sign contractor is to provide written certification that the sign installation conforms to all applicable codes and ordinances, and that it has been inspected and approved by the controlling agency. d. Tenant or its Agent shall obtain a sign permit from the reviewing jurisdiction for its sign and the installation thereof. f. The Landlord will provide primary electrical service terminating at the point shown on the plans. g. Tenants shall pay for all costs relating to the sign including the installation, final connections, photo cells/timers, and maintenance. h. Upon vacation of premises, Tenant shall arrange for removal of sign and filling of holes with appropriate material so as to create a waterproof assembly. Any damage caused by removal of sign or failure to make construction waterproof shall be Tenant's responsibility. i. In the event of any conflict between Tenant and Landlord as to the application of these criteria, Landlord's decision shall be final and binding. 2. Design & Construction Requirements for Fascia Signs. a. All signs shall be mounted on the canopies of the adjacent leased premises in accordance with Elevation Drawings 1 through 6 and Detail Drawings A and B. If the leased premises do not have a canopy, the sign construction and Tenant Signage Letter Elevation Line must be maintained in accordance with Elevation Drawings 1 through 6 and Detail Drawings A and B. b. A combination of channel letters and tag line sign "capsules" is acceptable fabrication. c. Landlord shall be the sole judge in its discretion as to conformance in accordance . herewith. d. Signs shall be of the following construction: i. Illuminated trim -capped or open pan individual channel letters with painted returns. ii. All signs shall be raceway mounted. The required raceway is Sign Comp (Part # 1981/1982/1986) extruded aluminum 7 3/4" high raceway. Raceways to be painted to match Sherwin Williams Black Fox (SW7020) with a satin finish. Prepared By: Jim Sutterfield —. Signs Plus -- 1330 N. Forest St. Bellingham, WA 98225 jims@signsplusnw.com — www.signsplusnw:com. — Cell: 360-303-3192 Page 1 of 3 • 4°6 BAKER RETAIL STORES - SIGN CRITERIA e. Signs shall be of the following size: i. In length, not more than 8'-0". ii. Maximum letter height is 2'-0". iii. Maximum overall sign height shall not exceed 3'-0" high. iv. More than one row of letters shall be permitted as long as the maximum height does not exceed those established above. Logos, crests, shields or symbols will be permitted. Construction Requirements i. Sign construction shall be in accordance with Detail Drawing A (One Line) or Detail Drawing B (Multiple Lines). ii. All signs, bolts, fasteners and clips shall be of glass, plastic, hot dipped galvanized iron, stainless steel, aluminum, brass or bronze. No black iron of any type will be permitted. iii. It shall be the sign contractor's responsibility to secure sign in a method so as not to create a hazard to the public. iv. All penetrations shall be made waterproof by using gaskets and sealant. v. The Tenants shall be responsible for any damage caused by the sign contractor, including roof and wall leaks, and parapet wall damage. vi. No labels will be permitted on the exposed surface of signs except those required by local ordinance and, if required, shall be in an inconspicuous location. vii. No exposed conduit will be permitted. viii. All electrical signs shall bear the U.L. label. ix. Electrical service to all signs shall be from Tenant's service. 3. Design Requirements for Entrance and Service Door Signs. a. White cut vinyl lettering only, shall be permitted on glass doors within the limits set forth herein: i. 144 square inches per entrance in lettering not to exceed two inches (2") in height, indicating hours of business, emergency telephone numbers, security sticker, etc. i. All lettering shall be white vinyl lettering on face of door. ii. Door is typical non -customer type for receiving merchandise at rear. 4. Design & Construction Requirements for tenant panels on Pylon Sign. a. Tenants are allowed advertising on the Pylon Sign as determined by the Landlord or Landlord's Agent in the Lease Agreement. i. Tenant is responsible for providing their own tenant cabinet in accordance with Detail Drawing C. ii. The Tenant shall be responsible for the cost of the sign cabinet, insert panels and graphics. iii. No variations from Detail Drawing C are permitted. iv. It shall be the sign contractor's responsibility to secure sign to the Pylon Sign properly in a method so as not to create a hazard to the public. f. g. Prepared By: Jim Sutterfield — Signs Plus — 1330 N. Forest St. Bellingham, WA 98225 jims@signsplusnw.com — www.signsplusnw.com — Cell: 360-303-3192 Page 2 of 3 4°6 BAKER RETAIL STORES - SIGN CRITERIA v. The Tenants shall be responsible for any damage caused by the sign contractor. vi. The Tenant shall be responsible for all removal costs and for any required repairs to the Pylon Sign from such removal upon vacating the space. 5. Prohibited Signs. a. The following types of signs are prohibited unless specifically approved by the Landlord or Landlord's Agent, and the reviewing jurisdiction on an individual basis. i. Signs employing moving or flashing lights. ii. Signs employing exposed conduit. iii. Signs of box or cabinet type with internal lighting. iv. Skeletal neon type signs. v. Pylon Signs. vi. Moving Signs. xi. Paper, cardboard or painted signs. xii. Audible Signs. xiii. Portable signs, including, but not limited to auto, truck or trailermounted signs and a -board type signs. xiv. Banner type signs. xv. Window graphics. Tenant Name: Address: Tenant Acceptance: Date: Landlord Acceptance: Date: Prepared By: Jim Sutterfield - Signs Plus - 1330 N. Forest St. Bellingham, WA 98225 jims@signsplusnw.com - www.signsplusnw.com - Cell: 360-303-3192 Page 3 of 3 Contractors or TradespeolPrinter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company Signs Plus Inc 3606717165 1330 N Forest St Bellingham Wa 98225 Whatcom Corporation UBI No. Status License No. License Type Effective Date Expiration Dat Suspend Date Specialty 1 Specialty 2 602475651 Acfiue SIGNSPI952LW Construction Contractor 6/16/2005 e 6Y1f6�/2011 Signs Unused Business Owner Information Name Role Effective Date Expiration Date Gravning, Dale President 06/16/2005 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 COLONIAL AM CAS Et SURETY OF MARYLAND LPM4069111 06/13/2005 Until Cancelled $6,000.00 06/16/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Continental Cas 4017784932 10/09/2009 10/09/2010 $2,000,000.00 10/21/2009 5 MUTUAL OF ENUMCLAW INS CO NC51846 06/01/2009 06/01/2010 $1,000,000.00 05/29/2009 4 MUTUAL OF ENUMCLAW INS CO NC51846 06/01/2008 06/01/2009 $1,000,000.00 05/29/2008 3 MUTUAL OF ENUMCLAW INS CO NC51846 05/01/2007 06/01/2008 $1,000,000.00 05/09/2007 2 MUTUAL OF ENUMCLAW INS CO RQ73838 06/01/2006 06/01/2007 $1,000,000.0006/01/2006 1 CNA INS CO LTD 2083965254 06/01/2005 06/01/2006 $1,000,000.00 06/16/2005 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 04/15/2010 C,f Tukwila PERMIT NO. 3) v O9 -I Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: y - —10 Tukwila, Washington 98188 206 431-3670 (,OLPTE 6 Business Name Si CPS. PLUS Applicant/Contact Address, City, State, Zip / SA Mt ,4SAPPi-icAt-er Contractor Please print EIVED 406 gAKei2 BLVD ST K 11 2 �G(o $RZ-21 Address of Sign Phone eyK O.8 Tb�il�t 330 P.Fo2enT'T Sruloda14A iWA1P.we 3Go, 671-716-5111 �(��/I Phone COMMUNITY DEVELOPMENT Address, City, State, Zip Phone CHECKLIST ❑ 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs ❑ Sign elevations with area calculations and dimensions ❑ Building elevations (for wall signs) ❑ Supporting structure and method of illumination ❑ One copy of valid Washington State contractor's license ❑ See attached fee schedule for application fee See back of form for examples Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? Yes ❑ No Wall WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) of the tenant space where the sign will be mounted? (square feet) •. ,-. Sign size(square feet) 23,4 Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. A' I v Does wall sign weigh more than 400 pounds?(Y/N) N Sign illumination (internalexternaVnone) Yr+tKa.p+AL. FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. E x1151))•) 6 Height of building (feet). Generally, signs may not be higher than the building with which they associated PA Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area / 1 0 7 /J A 18 Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. k%/P Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. N/ A I Number of si • n faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for foo ing or bracket inspections. Footing inspections must take place before concrete Is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the Electrical Permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. SIGN PERMIT APPLICATION IS VALID F. - 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me i • = and c the applicable requirements of the City of Tukwila will be met. 1//4/, / o Date ' D (SignatysfA'bfo 61 der penalty of perjury by law in the State of Washington, and that er or auth agent) MIkg) nSI hcplus.n., u. 004 mail dress FOR OFFICE USE ONLY Zoning: Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions Q) VICINITY MAP JOB SITE GOLFTECH 406 BAKER BOULEVARD SUITE # PARCEL # 0223100037 EXISTING "AMERICAN FAMILY INSURANCE " SIGN Yi-%i I I I EXISTING "MANPOWER" SIGN PLACE PROPOSED NEW WALL SIGN HERE PLACE TWO (2) NEW TENANT PANELS HERE BAKER BLVD SITE MAP Designed exclusively for: GOLFTEC 406 BAKER BLVD SUITE #2 TUKWILA WA 98188 GOLFTEC SHARED\PROJECTS\NORTHWEST CAPITAL\ 406 BAKER BLVD\GOLF TECH\SITE MAP.CDR 04/06/2010 1/32"=1' JIM SUTTERFIELD MIKE LINEBRINK THE IDEA COMPANY 1330 N. Forest Street Bellingham, WA 98225 ',r;', 360.671.7165 \,' . 360.671.0144 I;\ 1.877.298.4761 1,1>\ I.. sales@signsplusnw.com /'/l i ; ; I'.: www.signsplusnw.com THE COLORS SHOWN IN THIS DESIGN ARE ONLY A REPRESENTATION OF THE ACTUAL COLORS TO BE USED. THIS ARTWORK IS THE PROPERTY OF SIGN PLUS AND IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. ANY USES OF THIS ARTWORK OTHER THAN DIRECT BUSINESS WITH SIGNS PLUS WITHOUT WRITTEN PERMISSION SHALL CONSTITUTE YOUR AGREEMENT TO PURCHASE THIS ARTWORK, AND THE DESIGN PROPOSED. FINAL SALES DATE PRODUCTION DATE REVISION REVISION REVISION REVISION DATE DATE DATE DATE • • 22'-8" TENANT SPACE SOUTHEAST ELEVAT ON "uu �f� d OW Qo a 00 Ritnie-4 25 5(i9r07 no 41 C,k SOUTHWEST ELEVATION 3'-11" O) LU � Designed exclusively for: GOLFTEC 406 BAKER BLVD :SUITE #2 TUKWILA WA 98188 GOLFTEC SHARED\PROJECTS\NORTHWEST CAPITAL\ 406 BAKER BLVD\GOLF TECH\ELEVATIONS.CDR 04/06/2010 1:96 JIM SUTTERFIELD MIKE LINEBRINK t � $JznW 1.330 N. Forest Street Bellingham, WA 98225 °,. THE IDEA COMPANY 360.671.7165 360.671.0144 1.877.298.4761 sales@signsplusnw.com 'w ww.signsplusnw.com THE COLORS SHOWN IN THISDESIGN ARE ONLYA REPRESENTATION OF THE ACTUAL COLORS TO BE USED. THIS ARTWORK IS THE PROPERTY OF SIGN PLUS AND IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. ANY USES OF THIS ARTWORK OTHER THAN DIRECT BUSINESS WITH SIGNS PLUS WITHOUT WRITTEN PERMISSION SHALL CONSTITUTE YOUR AGREEMENT TO`.. PURCHASE THIS ARTWORK. AND THE DESIGN PROPOSED. HNA SALES DATE PRODUCTION DATE REVISION REVISION REVISION REVISION DATE DATE DATE DATE FRONT VDEW COLOR VIEW SPECIFICATIONS: INTERNALLY LIT CHANNEL LETTER DISPLAY TO INCLUDE 5" DEEP CHANNEL LETTERS AND ARC SHAPES WITH BLACK PAINTED RETURNS AND 1" BLACK JEWELITE TRIMCAP. FACES ON "GOLF" AND BOTTOM ARC TO BE WHITE #2447 PLEX WITH 3M TRANSLUCENT GREEN AND RED. FACES ON TEC AND TOP ARC TO BE BLACKNVHITE PLEX (BLACK WHEN SIGN IS OFF, WHITE WITH SIGN TURNED ON). ARCS ARE TO BE BACKED WITH .125" ALUMINUM FOR SUPPORT AND CONCEALMENT OF ATT HMENT. ALL PIECES ARE MO TED TO AN 8" EXTRUDED ALUMINUM RACEWAY PAINTED AP_.'e (MATE W .i_�. OLO; PE XISTING SIGN CRITERIA T4 SIG ` • REA SIN EIG RA WAY 1 �►,F 3.4 BS 0 TOP ANOPY END VIEW PROPOSED NEW SIGN ATTACH TO EXISTING CANOPY CHANNEL WITH 3/8" BOLT & NUT (MINIMUM OF 5 REQUIRED) EXISTING 12" STRUCTURAL CANOPY CHANNEL ATTACHMENT DETAIL CHANNEL LETTER • TYPICAL SECTION - FRONT -LIT PLASTIC FACE .040' ALUMINUM 5" RETURN 1" TRIMCAP 3/16" ACRYLIC NEON INTEGRAL SLEEVING GTO CONDUCTOR LISTED BUSHING NEON TUBE SUPPORT ELECTRODE INSULATING BOOTS AND SLEEVING 114' DRAIN HOLES (LETTERS AND RACEWAY) .060' ALUMINUM 7" X 7" EXTRUDED ALUMINUM ENCLOSURE FASTENERS AS REQ'D. BY LOCAL JURISDICTION LISTED DISCONNECT SWITCH (NEC 600-6) WITHIN SIGHT OF SIGN PRIMARY ELECTRICAL (NEC 600-5) SEE ELEC. NOTES 30 MA TRANSFORMER (NEC 600-23) UL 2161 N.T.S. LISTED agp 17-239003 rug caDit Co parry be done ELECTRICAL NOTES 113? ffaxuala paw to @col electrical p licensed ( contractural) dedleated & ARAN •e I BJ Oft c•egp . 4 Thr u. o i (:mu ri Mout.' Designed exclusively for: GOLFTEC 406 BAKER BLVD SUITE -#2 TUKWILA WA 98188 GOLFTEC SHARED\PROJECTS\NORTHWEST CAPITAL\ 406 BAKER BLVD\GOLF TECH\SIGN DETAIL.CDR 04/06/2010 1:16 JIM SUTTERFIELD MIKE LINEBRINK SC�gl05 °„OIIS� THH E OEA COMPANY 1.330 N. Forest Street Bellingham, WA 98225 360.671.7165 360.671.0144 1.877.298.4761 sales@signsplusnw.com ,w ww.signsplusnw.com THE COLORS SHOWN IN THIS DESIGN ARE ONLYA REPRESENTATION OF THE ACTUAL COLORS TO BE USED. THIS ARTWORK IS THE PROPERTY OF SIGN PLUS AND IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. ANY USES OF THIS ARTWORK OTHER THAN DIRECT BUSINESS WITH SIGNS PLUS WITHOUT WRITTEN PERMISSION SHALL CONSTITUTE YOUR AGREEMENT TO\ PURCHASE THIS ARTWORK, AND THE DESIGN PROPOSED. SALES CDp�� DATE > ::V. IU ® M' PRODUCTION Q„) l.k ®— 0 r. DATE (' <21:c REVISION REVISION REVISION REVISION DATE DATE DATE DATE • Gollfirec 1 406 Baker 8'-0" White piex panel with 3M Matte Black, translucent Red, and Green vinyl graphics for both sides of existing monument sign. Measurement to be field verified. Simulated Installation View not to scale c ru- © 2010 Signs Plus 1 This artwork is the property of Signs Plus and is protected under state and federal copyright laws. Any uses of this artwork other than direct business with Signs Plus without written permission shall constitute your agreement to purchase this artwork, and the design proposed per US Copyright Law Title 17/92 Chapter 5. Golftec 2-15-09 Jim Sutterfield Projects/Northwest Capital/406 Baker Blvd/Golf Tech/Golf tec 1 Underwriters Laboratories Inc.® LISTED 311_ MATTHIEWs FAINT MAVER FABRICATOR ILA Thl INTERNATIONAL SIGN ASSOCIATION 360.671.7165 360.671.0144 1.877.298.4761 jims@signsplusnw.com www.signsplusnw.com Jig q. -; r 4E -7 -all zy --' THE IDEA COMPANY 1330 N. Forest Street Bellingham, WA 98225