Loading...
HomeMy WebLinkAboutPermit S01-052 - GAMESTOPSO1-052 GAMESTOP .COM 16874 SOUTHCENTER PKY • INSPECTION NO. INSPECTION RECOR• Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 98188 hof-dSZ 053 PERMIT NO. (206)431-3670 Project: 511:10 Type of Inspection: AddCAiwtA2.- ress:4 ) Date called: Special instructions: Date wanted: a.m. p.m. Requester: ' `- (-0'�^-P'c� ) ? l�-,^'`� Si Pte; ; — 413 — 3323 .x,k - Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: Inspector: Date: n $47.00 REINSPECTION EEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: SITE INSPECTION (PLANNING) File No. S2001-052 Name of Tenant: GameStop.Com Sign Address: 300 Andover Pk W. Date Photo Taken: 8/28/01 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of (date) Make new site visit and taken photo by (date) Comments: City of Tukwila Department oI) munity Development 6300 Southcer��FBoulevard, Suite 100 DATE: Tukwila, Washington 98188 (206) 431-3670 PERMIT N ` D PERMANENT SIGN PERMIT APPLICATION Gamestop.Com Business Name Connie Guffey Applicant/Contact Plumb Signs Inc. Contractor LJ Er Please print 300 Andover Park West Address of Sign 5838 S. Adams, Tacoma 98409 Address, City, State, Zip Phone 253 473 3323 X10 Phone 5838 S. Adams, Tacoma, 98409 253 473 3323 Address, City, Slate, Zip . Separate application required for each sign proposed 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $50 application fee per sign, or .50 cent per sq. ft., whichever is greater. See back of form for examples Phone Is your sign a: • O Freestanding sign 15 or more feet in height O Pole sign with face 30 square feet or more In area O Wall sign weighing 400 pounds or more If any of the above are true the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: O $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the design of the details prepared by a Washington State structural engineer SIGN DESCRIPTION Is the sign: Ig Internally lit 0 Externally lit 0 Not lit Does the sign face residential zones or public facilities? ❑ Yes 17}N° Exposed neon tubing Is not allowed within 200 feet of LDR, MDR or HDR zones. Did building go through design review? ❑ Yes ❑ No Including this sign, how many signs will list this business? Freestanding Wall 1 WALL SIGN: West Elevation What is the wall area (length x height) where the sign will be mounted? 94 5 square feet Wall sign size: 39 • 37 square feet Does wall sign weigh more than 400 pounds? 0 Yes AlixNo If the sign weighs more than 400 pounds It requires structural review. See checklist for additional information required. FREESTANDING SIGN: Street frontage of the entire premises where the sign will be located: feet Generally, only one freestanding sign Is allowed per premises. Size of sign face: 'square feet Structural review Is required for pole signs with faces 30 square feet or more In area, (see checklist for additional information required). Number of sign faces: Height of building: feet Generally, signs may not be higher than the building with which they are associated. Sign height: feet Inches Structural review Is required for signs 15 feet or more In. height, (see checklist for additional information required). Distance from closest edge of sign to property lines: feet Generally, signs must be set back from all property lines a distance equal to their height. INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspectioris must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or ir)staller Is required to call the Planning Division at 431-3670 for a final Inspection. It Is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above Information furnished by me is true and correct under penalty of perjury by law in the Stale of Washington, and that the applicable requirements of the City of Tukwila will be met. 7/J2/01 Date Zoning: (Signature f owner o rued nt) FOR OFFICE USE ONLY Planning review by: ❑ Denied 253 473 3323 X10. Phone 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions Actual time spent to review Additional charges for time over 2 hours Comments or Conditions: City of Tukwila • (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Status: Type: Category: ISSUED P-PSIGN WALL PERMANENT SIGN PERMIT Address: 300 ANDOVER PK W Location: WEST FACADE Parcel #: 262304-9119 Zoning: TUC OWNER SEGALE M A INC PO BOX 88050, TUKWILA WA 98188 CONTRACTOR PLUMB SIGNS 5838 S ADAMS, TACOMA, WA 984092613 APPLICANT GAMESTOP.COM PLANNER MINNIE DHALIWAL Permit No: S01-052 Issued: 07/11/2001 Phone: 206 473-3323 **•************************************************************************* Permit Description: WALL SIGN 39.37 SO. FT. "GAME STOP" Total Permit Fee: 50.00 PERMANENT SIGN: SIGN LIGHTING: INTERNAL WALL SIGN Wall Area (Sq. Ft.): Wall Sign Size (Sq. Ft.): Face Residential Land: N 945.00 39.37 FREESTANDING SIGN - Street Frontage for Entire Lot (Ft.): .00 Bldg Height (Ft.): .00 Sign Size (Sq. Ft.): .00 Sign Height (Ft.): (In ): Setback (Ft.): .00 Number of Sign Faces: ****************************************************•********************** `f fr'2AA)-% Planning Division Authorized Signature Date It is the responsibility of the installer to obtain the electrical permit and inspections from the State Electrical Department. The applicant or installer is required to call the Building Division at (206) 431-3670 for a final inspection. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. • G N WALL AREA-WEST ELEVATION : 27' X 35' = 945 SQ. FT. = 42.80 SQ. FT. ALLOWED SIGN AREA - WEST E EVATION: GAMESTOP.COM = 2'6" X 15'9" = 39.37 SQ. FT. PROPOSED ;51,0" WEST ELEVATION SCALE: -I/8" = 1 '-0" 1 of 8 #817 Tukwila, WA EXISTING PROPOSED * Remove existing Super Software letters and add 30" GameStop channel letters. #81 7 ThkwIIa. WA DWG. #20105088401` S4LES KYNETTE SETEAR ACC. M. DEB BIANCHI ART J. STROUD /05.31-01(O -OI cif) NO7E' IF ANY FIELD MEASUREMENTS DIFFER FROM Tlh'OSE ON T1 -1/S PRINT PLEASE 141077FY NORTH AMERICAN SIGNS AT 1(800)348-000 • 2of9 15'-9 3/4" SIGN DETAILS SCALE: 3/8" = 1%0" CHANNEL LETTER SECTION W RACEWAY NOT TO SCALE tiRlIDEIMIIIMS ILA.BOTAWILEI£S LISTED P/C. ELECTRIC SIGN "GAME" DETAILS: FACES: 7328 WHITE PLD( T1101 CAP: 1' BLACK HEOPk 15 mm. 6500 WWI "STOP" DETAILS: FACES: 2793 RED PLLEX TRW CAP: 1" RED (EON: 15 mm, 04 CLEAR RED "COM" DETAILS: FACES: 7328 WHUE PLEX COPY: 3630-33 RED VINYL TRPA CAP: 1- BLACK NEON: 15 mm, 8500 WHITE RETURNS: MATERIAL 040 ALUMINUM COLOR: PRE -FINISHED BLACK OUTSIDE - WHITE INSIDE BACKS: MATERIAL: .080 ALUMINUM OR GREATER TRANSFORMERS: TYPE: REMOTE MA: 30 ma, 120 VOLT 3" BORDER MATERIAL .080 ALUMINUM OR GREATER COLOR: PAINTED GLOSS BLACK MOUNTING 0 Lift ON CENTER MOUNTED RACEWAY WITH NON-CORROSVJ FA.STFNFRS. AS REQ nRcn' c #823 Seattle, WA nillamiguan DWG #20105079-02 SALES KYNETTE SETEAR ACC. M. DEB BIANCHI ART J. STROUD 105-29-O1(064341 a. CZI LETTER DETAIL FOR WALL MOUNT PAN CHANNEL LETTERS ALL SIGNS AND COMPONENTS ARE UL APPROVED AND MEET STATE AND LOCAL BUILDING AND ELECTRICAL CODES SHEET METAL LETTERS - BACKS & SIDES EACH LETTER WEIGHS APPROXIMATELY 2 1/2 - 3 LBS. SHEET METAL RETURNS 1" TRIM CAP PLEX FACE NEON TUBING #8 SCREW HOLDING FACE AS NEEDED AROUND EACH LETTER GLASS STAND TWO 1 1/2" HOLE PER LETTER WITH PK 1/2 FLEX CONNECTOR I/2"FLEX CONDUIT `HIGH TENSION WIRE TRANSFORMER BOX G.F.I. TRANSFORMER 00 1 5" _N. DEPTH OF EACH LETTER 1/4" X 1 1/2" NYLON & METAL TAPITS INTO CONCRETE - TOTAL OF 6 ATTACHMENTS WALL NO SCALE Rom „2.,,9,11.., 8 of 8 GAMESTOP� #817 STRANDER BLVD. #817 7LkwIIa, WA �i��Ei8cE1Q�LE BOOKSELLERS NEW %.` d A eon. 1 l ANDOVER PARK WEST SITE PLAN FOR GAMESTOP #817 TUKWILA, WA /U R.T/41 510111- #817 #817 Tukwila, WA rarrlialingitrinetitjjnean DWG 1720105088-01 SATES KYNETTE SETEAR ACC. M. DEB BIANCHI ART J. STROUD / 05-31-01 p:0. of cv) NOTE: IF ANY FIELD MEASUREMENTS DIFFER FROM THOSE ON THIS PRINT PLEASE NOTIFY NORTH AMERICAN SIGNS AT 1(800)348.5000