HomeMy WebLinkAboutPermit S01-076 - DEJA VUSO1-076 DEJA VU 15011 INTERNATIONAL BL SITE INSPECTION (PLANNING) File No. S01-076 Name of Tenant: DEJA VU Sign Address: 15011 Tukwila International Blvd, Tukwila Date Photo Taken: 7-25-02 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of (date) Make new site visit and taken photo by (date) Comments: City of Tikwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 PERMANENT SIGN PERMIT Parcel No.: 0041000516 Permit Number: SO1-076 Address: 15011 TUKWILA INTERNATIONAL BL TUKW Issue Date: 01/24/2002 Suite No: Permit Expires On: 07/24/2002 Business Name: DEJA VU Phone: Address: 15011 TUKWILA INTERNATIONAL BLVD, TUKWILA WA Property Owner: Name: KANG HEE YEOL & SEE JEE Phone: Address: 15022 MILITARY RD S Contact Person: Name: LOREN DEMUTH Phone: 360-650-1150 Address: CUSTOM DESIGN SIGN/AWNING INC Contractor: Name: CUSTOM DESIGN SIGN/AWNINGS INC Phone: 360-650-1150 Address: 423 KENTUCKY ST DESCRIPTION OF WORK: WALL SIGN 31.14 sq. ft. "DEJA VU SHOWGIRLS" Fees Collected: PERMANENT SIGN: $50.00 Zoning: RC Sign Type: WALL Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 675 ?? ?? ?? Wall Sign Size (sq. feet): 31.14 ?? ?? ?? Sign Lighting: Face Residential Land: N ?? ?? ?? Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 ?? Building Height (feet): 0 ?? Sign Size (sq. feet): 0 ?? Sign Height (feet and inches): 0' 0" ??' ??" Setback (feet): 0 ?? Number of Sign Faces: 0 ?? Planning Division Authorized Signature: Date: /// 2— I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. rind Permsian S01-076 Printed: 01-23-2002 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director PLANNING DIVISION COMMENTS DATE: September 18, 2001 APPLICANT: Deja Vu RE: Tenant Improvement D01-296 ADDRESS: 15011 Tukwila International Blvd. Please review the following comments listed below and submit your revisions accordingly. If you have any questions on the requested revision, Deb Ritter is the planner assigned to the file and can be reached at 206-431-3663. Your application has been deemed incomplete. Per TMC 18.60.030(B)(2)(b), approval by the Board of Architectural Review is required for any exterior repair, reconstruction, cosmetic alterations . or improvements if the cost of that work equals or exceeds 10% of the building's assessed valuation. Please provide the following: 1. Documentation from the King County Assessor's office stating the current assessed value of the building. 2. A breakdown of the total dollar value of the proposed improvements showing labor and materials needed for your proposal. We are enclosing a copy of the Design Review application packet for your reference. You will be required to submit a design review application if the cost of the proposed work equals or exceeds 10% of the building's assessed valuation. Additional Comments: You currently have a sign permit application pending with the City of Tukwila under File S01-076. However, it appears that your proposed signage (shown in the drawings for D01-296) is larger than the allowed maximum under the Tukwila Sign Code. Please contact Minnie Dhaliwal, Associate Planner at 206-431-3685 as soon as possible regarding your sign proposal. 0300 Southcenter Boulevard. Suite #100 • Tukwila, Washington 98188 • Phone: 2Ob-431-3670 • Fax: 2O6-431-3605 City of Tu$ila Department of Community Develom@NED 6300 Southcenter Boulevard, Sajtpe rIJIMPAATE: Tukwila, Washington 98188 1 2 2001 (206) 431-3670 SEP PERMIT NO. • PERMANENT SIGN PERM APPLICATION M (/{� \/— iddress lease inName of Sign e.i&r^P tH ,Avvropesinciii-t' Sf- ApplicanUCont/ 7 11 11 Address, City, City, State, Zip A .014' 4ke/�U031-' -• 1/214V/°1 Mon rector Address, C y, State, Zip G. Separate application required for each sign proposed 3 sets of plans (dimensioned and scaled), including site plan showing: • Property fines • Streets • Buildings • Locations of all existing and proposed signs ign elevations with area calculations and dimensions uiiding elevations (for wall signs) upporting structure and method of illumination One copy of valid Washington State contractor's license $50 application fee per sign, or 50 cents per sq. ft., whichever is greater. See back of form for examples jrnone Phone 6) one t6) 65o—il Is your sign a: ❑ Freestanding sign 15 or more feet in height O Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the'proposed foundation or wall attachments (see back of form for examples) O Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION Is t e sign: Internally lit ❑ Externally lit ❑ Not lit Does the sign face reside ial zones or public facilities? ❑ Yes No Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. Did building go through design review? ❑ Yes 0 No Including this sign, how many signs will list this business? Freestanding Wall WALL SIGN: What is the wall ar o (length x height) where the sign will be mounted? square feet I' Wall sign size: square feet 3I') 4 Does wall sign weigh more than 400 pounds? ❑ Yes NO if the sign weighs more than 400 pounds It requires structural review. See checklist for additional information required. FREESTANDING SIGN: Street frontage of the entire premises where the sign will,be located: feet Generally, onlyone freestanding sign Is allowed per premises. Size of sign face: square feet Structural review Is required for pole signs with faces 30 square feet or more in area, (see checklist for additional Information required). Number of sign faces: Height of building: feet Generally, signs may not be higher than the building with which they are associated. Sign height: feet inches Structural review is required for signs 15 feet or,rnore In height, (see checklist for additional Information required). Distance from closest edge of sign to property lines: feet Generally, signs must be set back from all property lines a distance equal to their height. INSPECTIONS If the sign needs structural review, the applicant or installer is required Id call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concreted:, poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is lie responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is tru the apprcable requirements of the City of Tukwila wi I be met... 2- /01 Date Zoning: C) rect under penalty of perjury by law in the State of Washington, and that raio Signure of owner or authorized agent) ((go Phone FOR OFFICE USE ONLY Planning review by: ❑ Dented p-§ Issued 0 Issued with conditions Structural review required? ❑ Yes ❑ No Structural review by: ❑ Denied 0 Approved 0 Approved with conditions Actual time spent to review Additional charges for time over 2 hours Comments or Conditions: T u. . 1 a Train / ign .Area Sign Area Is calculated by constructing a polygon around the sign using right angles., Hobby Big Store \ .\. \ \ \ \ \ \ \ \ \\ \\ : \\\..\\\ \\\ Building Elevation • Wall Area Is calculated by multiplying (he lehgth and height of the tenant space. -4 Site Plan SITE/LEASING PLAN 111. 1.0n1 AMO COMBO n1M11 An■ Pt APIn11I10 API P111 11A11 0,1.0 LOCA1. IOM0m0 AMO 11.1 CIniCAI 00011 11111? MIIA1. t1111M1 . IAC0I I IIOH RAIL Wall Mount Detail For all wall mounted signs over 4001bs: J 1ita1.PIKE w.l0. I' 'Tb Pct.s PNO ATTAtu?Cp -RJ 61e,vJ w/ %. HEK Buz.-rsfr. %L' m SUI 10 rot, - Footing Detail Show applicant space•and all existing & proposed signs. For all Freestanding Signs XAMPLE OF REQUIRED INFORMATION r Detach And Display Certificate — DEPARTMENT UF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR SIGN LICENSE # EXP. DATE ECO4 CUSTODS066BR 01/19/2002 EFFECTIVE DATE 01/19/1994 CUSTOM DESIGN SIGN/AWNING INC 2121 LINCOLN ST BELLINGHAM WA 98225 F(, 5 $I:• l.N),..97. 1 DEPARTMENT OF LABOR .AND INDUSTRIES CERTIFIED AS PROVIDED BY LAW AS ADMINISTR SIGN .CERT. # EXP. DATE ADO4 .RINASL*121NF 12/26/2001 EFFECTIVE DATE 08/06/1988 RINAS, LON 6199 CHURCH RD FERNDALE WA 98248 iti ,4 ,5 15 'S !' 1 F625-052-000 (8/971 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL EXP : DATE . ,....7'1:11,1r -REGI ST .:. `#::-; .. 0001:;'i<'��CUS.TODS0.42L6- 06/28/2002. EFFECT IVE`,.'DATE1 .` i'0.6:/26=/`199.6. CUSTOM DESIGN-SIGN/AWNINGS INC 423 KENTUCKY ST BELLINGHAM WA 98225 Detach And Display Certificate — DEPARTMENT UF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR SIGN LICENSE # EXP. DATE ECO4 CUSTODS066BR 01/19/2002 EFFECTIVE DATE 01/19/1994 CUSTOM DESIGN SIGN/AWNING INC 2121 LINCOLN ST BELLINGHAM WA 98225 F(, 5 $I:• l.N),..97. 1 DEPARTMENT OF LABOR .AND INDUSTRIES CERTIFIED AS PROVIDED BY LAW AS ADMINISTR SIGN .CERT. # EXP. DATE ADO4 .RINASL*121NF 12/26/2001 EFFECTIVE DATE 08/06/1988 RINAS, LON 6199 CHURCH RD FERNDALE WA 98248 F12 ago c; s 9OLT Fiatkriff- eONST, C7OI NT / gAricysit. ALL a-F'ST �rtot4 Cort 6:X1111144 • •_ I6N� •' \4 2 0 �— 3•�Z� FPr.*27 3 $ _1n ij .3 W I 3 R � D E 3 3 itli :isf 1` i m Sl Zi O Psi' - l'fedi ig: 0 11,0 7.0 op ,o . .,, t„,,,,,,i4 0 v, '�K7 PA#d' fl' —� yc-R.,e CT • *(7 T Tts.rt. NorT1oN11.1_-. ��D) ELF \a -,-1 NI PAGE J1 3/dit' ■1 CERTIFICATE OF FLAME RESISTANCE This certifies that A W1VMAX, when distributed by Western Rim Industries Ltd. has been flame-retardant treated, or is inherently nonflammable. TO: CuSrom 54.i 5igo %If t / i/ D2 . 2 Z I Lii1 (a),v 5t-ael/iTha.iy) qN-ZS - AWNMAX successfully complies with the requirements for: UL -214 R 14659 9T39 ULC -S 109M R14659 9T39 -NEPA 701 R14659 9SSC01615 ASTM D568 N( 13(12 9asc. i a4(j l ASTM F84 with a nit ing of 20 (A) Company /o /`/- cf.?_ Pate ■ L® • Cizy of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director PLANNING DIVISION COMMENTS DATE: October 12, 2001 APPLICANT: Deja Vu RE: Tenant Improvement D01-296 ADDRESS: 15011 Tukwila International Blvd. October 11, 2001 response to Incomplete Letter #1 Please review the following comments listed below and submit your revisions accordingly. If you have any questions on the requested revision, Deb Ritter is the planner assigned to the file and can be reached at 206-431-3663. Your application has been deemed incomplete. We have received your resubmittal dated October 11, 2001. Per TMC 18.60.030(B)(2)(b), approval by the Board of Architectural Review is required for any exterior repair, reconstruction, cosmetic alterations or improvements if the cost of that work equals or exceeds 10% of the building's assessed valuation. Please provide the following: 1. Documentation from the King County Assessor's office stating the current assessed value of the building. The information you have provided is for the wrong address (15015 Pacific Highway South). The address of the Deja Vu is 15011 Pacific Highway South. 2. A breakdown of the total dollar value of the proposed improvements showing labor and materials needed for your proposal. You have only shown two lump sums: labor at $3,000 and materials at $1,400. This is not acceptable. As requested on September 18th, you must show a breakdown of the labor and materials that make up these totals. We have been provided with a copy of the Design Review application packet for your reference. You will be required to submit a design review application if the cost of the proposed work equals or exceeds 10% of the building's assessed valuation. cc: Minnie Dhaliwal 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431-3670 REVISION. SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 9-19-01 Plan Check/Permit Number: D01-296 Response to Incomplete Letter # _1_ Response to Correction Letter # El Revision # after Permit is Issued Project Name: Project Address: Contact Person: Deja vu Sign/Awning 15011 Tukwila International Blvd Loren DeMuth Summary of Revision: Phone Number: (360) 650-1150 ) Plec/71 F-fric E'\-2o�5 I . )PA ru '/C3 0 0 11rte (, C`i LevZf\Y-(-)c:\lel =? t c: rTw crry OF TUKW�(VEDILe, P� RMi tt Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Sierra on �� �� - 09/19/01 • OCT. -03' 01 (WED) 09:32 CONS0I411TED BKKPG HP1U ER 4300-0516-08 ALIPARTS WHEN PAYING IN PERSON KEEP TR11 THIS PORTION 1S022H1E1I ITARY8RDE5 JEE SEATTLE bA TEL:206 32090 CItgRFNI 911. LING DIST1:118uTION SiAls LOW Esme &ppm Mk 1.10ko 1penled$U 8d ...._ wl Pee seer 6fp W{Ior 1,42.38 2,5d .62 702.98 1,409.68 86.18 252.44 CmeryweTsiw8fe ._ 121.52 • tales ptlreee ,.. `_ TomC1>Ame mum, 9 4 730003 *OOTHERR CHHARGE'S • 2� 394 981188 ELOCY COOL SEC• WO Rc ra% stoat r,t somas as a.wted MI i" 4 2 413 lees. p sol UN piss sty 091S. DAMS HOME TRS 1ST ADD N.3fl MIl eepieer17etebse i SLY 90 FTO OF tdLY 150 FT OF 1 ' I,.e r°i� 1.4 OR NL``Y OF LN BAP if W LN 8301F58NEY190. SW COR 1 THrum 1Mar � PROPERTY ADORES S 75 15 PACIFIC HW S tem P. 002 u11,ENT'BILLIVC+DISTMEUT10N 49.0; =4-01 EUNOUENT1171716 WITH ND'PAl(ME�IT}'• 2oo1:IReAi,°E91r • Elm/ TaicAdtdtrNTN1A1106A�rn"� • ' KiNG COUNTY181i1141t... j i 41: RM 600.600 FOURTH MIME(' • T,TLE 681042387 0104100-0516-08 . Metra the* Tax inforniatfdij��((��06j 2913492 eck payable to: KING cOUN'rYTp6A$ NT/A.Ypu canceled ateOi I ybwR i-4 i' and half Must bo paid or postmarked by October 31 TAx ITAX OWt INTERC3T C BECOMES DEL1N0UENTAND ACCRUES ANNUAL rrne vFAa ERESTAND PENALTY ' SEA 15E KA022Lfix TARYUL gRDES JEE 1 730003 98188 Cowl erlAid 0 MALTY 5EE REVERSE PRiMCERALAmoUNT FIALI: AMOUN .19 3,260.19 100000000000000000000000d00000000000000000000000000dd00000410005160800032601916 WITHffSTPAYMENT 1ERTY TAX ACCOUNT NUNGER ' 004100-0516-08 •y.. 2001 REAL ATE TAXA' '' 1 TNO COUNTY STATE:OF WASFtI r N` RM 600 - 500 FOURTH AVENUE. SEATTLE 38104 4387 isomsMet makeProperty Tax Information (206) 298-0923 Qualm. ko t o>st . � . think payable to: KING COUNTY TREASURY. Your oarteeRed *hook is your receipt..: hall payment must be paid or postmarked by April 30th TITRE 91 UNG BECOMES DELINQUENT ANO WILL ;RUE ANNUAL INTEREST AND PENALTY L AMOUNT MAY B PAID APRIL 30th KANG HEE YEOL & SEE JEE 15022 ITILITARY RD S SEATTLE WA 730003 98188 TAX TYPE c.».R Orithpf 1f1~ rpm TAX a1 osaT 1: f — 01 Kromry rSEE pmPsE1 i • q P+Hctom.AI.OLM * HALF AMOR 6520.39 1/i 32611.20 rtiild. the rpHia .12,04.4.4COM :Tit:ST '4' PEN;14T7wMn oUtj 7. 3,260.2 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnt1100051601annngPL.nan1U SCALE 112" = 1' _31 SQ. FT. SIGNAGE AREA 60-0 " AWNING SECTION SHOWGIRLS SCALE 3`16"= 1' INCIDENTAL SIGNAGE/HOURS OF OPERATION, ETC. TO NOT EXCEED AT 6 SQ. FT. OF SIGNAGE AREA ALL OTHER EXISTING SIGNAGE TO BE REMOVED The <doe e,a.n m et.e aerim ae aa, mYrlAti e m S a+a< Ten air! hs,ngs and vealcxuna ♦prcspettry .kC'a I .,dthalK C,o,n Nur Inc ,CU, mtl w1 na benp^xii<el n eh& am pato untl tln<aexd mngaem .+n in Ow {Ric., nem porn. won cr CDI Client: DEP, V1! Die: 10'1 1 :73i He Nine. ti ternatblr'di.ecu Scale: As noted Dssigner: TIM PARIS Account Exe c e : LOREN DEn1U1H Revision: 1 2t20 2001 • INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 P,ar1e_cm L Typinspectyon:, r //7Z•U RData/ /O of Special instructions: Date wanted: . a.m. p.m. Reque t r: . /Teri Phone: ❑ Approved per applicable codes. n Corrections required prior to approval. COMMENTS: Inspector: Date: n $47.00 REINSPECTION fEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: / • • • • • • • • 34U4 Lt / PROPOSED AWNING " S cQ►2 fir. J c.., -((SIT -- 391q L53 JOB NAME: De'a Vu (TUKWILLA) SCALE: N.T. S A SECT.A EXS I STI N Vff-- ,.) .' L % 60' G BUILDING OVERHANG • GROCERY STORE PROPERTY LINE 110". 111 POWER: (1) Designated 120v/20amp. circuit w/disconnect at awning otjA Com, , ��� 3Xba = 6`7S kw �H D"rc °^ 2.5+ G% . (6.75 -Si ' 32V rytl-Ue- 151 -.79411 - 113/4 � 0 -„t•65 x/.C13 ; 31.114 ENTERANCE / _ / REMOVE EXISTING POLE SIGN I • • E-,7 iS 1.7& ,4_ I / 3"›< 6,0 ` (-to rz00P) ca -5 2. save_ Fr &e_ofi°,li �4- (' r'1/oITZY' A-Lg-4 2-s +(. 04- X 75 ) GAS STATION DATE: 7/30/2001 Site Mari Tukwilla2.ai V PARKING .11 al PAGE I m5 SITE FLAN THESE DRAWINGS AND SPECIFICATIONS ARE PROPIETARY AND/OR CONFIDENTIAL TO CUSTOM DESIGN, INC. (CDI), AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART, OR USED IN ANY MANNER EXCEPT IN THE COURSE OF "DOING BUSINESS" WITH CDI, WITHOUT PRIOR PERMISSION OF CDI. SIGN&AWNING (360) 650-1150 �z. M 2 - r v 1 471 3 ,o Zo/1 /O, 7 5x/sr� oVE/Z 199,416 /sT� /3 Lea,; a 0 — pJ JOB NAME: 77/....41' .i4 vrL) 7-7) Lc- A SCALE: 3//(a'1 = / �O SPECIFICATIONS: U 1 Nr N C, 4, -(4F•/64 -770A19 ,ciajM L, DATE: -7/ - j Q ' U / FILE NAME: or THESE ORIGINAL DRAWINGS AND SPECIFICATIONS ARE PROPRIETARY AND/ORCONFIDENTIAL TO CUSTOM DESIGN, INC. (CU) AND SHALL NOT 8E REPRODUCE IN WHOLE OR IN PART, OR USED IN ANY MANNER EXECPT IN THE COURSE OF • DOING BUSINESS' WITH CDN, WITHOUT PRIOR WRITTEN PERMISSION OF CDN. Cs I 1 1 CUSTOM (7) DESIGN S1GN&AWNING INIMIIINEMINGEBENCIUMMEMI COMMERCIAL SIGN & GRAPHICS DEPT. II,... Nw..d i.. 360) 650.1150 1.800-3824877 (360) 6500399 back bar brace welded structure alum typical framing plan field bolt sign & awning deja vu D P a-Ptc I 5T 4.3OOk '7/2UGT LACE RAIL RADI(J5_ 3/8" x THRU BOLT OR LAGS x4 I/ T51x1x0.063" BACK BRACE @ 7-6" o.c. TYP (7 plc.) 1/ V(2 -7C "1"•-'P) PROPOSED AWNING r sit -To 5 4 1: 74o w► F o Coe C -RAIL 3' 6' Caovo .,I4k'eV- PROJECTION EXISTING ROOF OVERHANG 14-vg/H 61o,se, 7 -or -z TYPICAL AWNING MOUNTING SECTION "A" Finished Grade Topp o /On 1/�_r OR- e'Tie-LG7 %- iz e lVO(c', .1151-, 1' 1.t JC47et.F LO& JOB NAME: Deja Vu (TUKWILLA) SCALE: N.T.5 Site Plan Tukwilla.ai PAGE DATE: 7/30/2001 THESE DRAWINGS ANO SPECIFICATIONS ARE PROPIETARY AND/OR CONFIDENTIAL TO CUSTOM DESIGN, INC. (CDI), AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART, OR USED IN ANY MANNER EXCEPT IN THE COURSE OF "DOING BUSINESS" WITH CDI, WITHOUT PRIOR PERMISSION OF COI. CUSTOM ri). DESIGNS: SIGN& A'r'./NIN1G (360) 650-1150 el 1/2"SHTG OPTIONAL 1 1/2" DRYVIT ANCHOR DIA. & LENGTH • 84$4 x 4 N a'f 0?‹ #" ANCHOR DIA. & LENGTH N TOGGLE ANCHOR DETAIL 1 MIN. EMBEDMENT STUDS 16" O.C. INTERIOR 1/2" SHTG o imustuos tountattime-11 1 1 STUDS CD 16" O.C. ,‘ . OPTIONAL BRICK VENEER DROPLATCH ANCHOR DETAIL 2 MIN. EMBEDMENT 2000 P.5.I. 3500 P.S.I. INTERIOR ULTIMATE TENSION & SHEER LOADING IN LBS. 2000 P.S.I. 3500 P.S.I. =-ZS no 541 - d 0 ohm 804 30 Z o N WILW2= Q. Z y 0 00zo�o ziSmoa §>-($31115 >o3W5 S¢?QQW ng”):." yyooO E.MGtWd TENSION SHEER TENSION SHEER TENSION SHEER TENSION SHEER 31/2" LAG EMBED INTO EXIST STUDS 16" O.C. OR HEADER * NOTE BLOCKING TO SPAN EXIT VERTICAL STUDS OR EQUAL TO SPREAD LOAD TO EXIST WALL STRUCTURE 3/8" 0 ALL THREAD CUT TO LENGTH INTERIOR * OPTION 2 24" xL2x2x 1/8" ANGLE W/ 1/2" 0 HOLE IN MIDDLE * OPTION 3 24" 2" x 4" WOOD BLOCK W/ 1/2" HOLE IN MIDDLE LAG ANCHOR DETAIL 3 MIN. EMBEDMENT THRU BOLT ANCHOR DETAIL 4 ANCHOR DIA. & LENGTH -3/0 13 4fi 2000 P..5.I. 3500 P.S.I. TENSION SHEER TENSION SHEER MIN. EMBEDMENT T L7 / 2000 P.S.I. TENSION SHEER 3500 P.S.I. TENSION SHEER STANDARD ANCHOR DETAILS