Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL13-0323 - FRUITITUDE - REMODEL
FRUITITUDE 100 SOUThCENTER MALL EL1 3-0323 City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 9202470010 Address: 100 SOUTHCENTER MALL TIIKW Project Name: FRIIITITUDE ELECTRICAL PERMIT Permit Number: EL13-0323 Issue Date: 04/11/2013 Permit Expires On: 10/08/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MATT SNYDER Address: 900 N 34 ST, STE 104 , SEATTLE WA, 98103 Contractor: Name: TITAN ELECTRIC INC Address: 900 N 34 ST, SUITE 108 , SEATTLE WA 98103 Contractor License No: TITANEI9630B Phone: 206 383-0517 Phone: 206-633-2811 Expiration Date: 09/02/2014 DESCRIPTION OF WORK: 1N4%,1 atna civAlfA'S Value of Electri: NRES: $28,000.00 Fees Collected: RES: $0.00 Type of Fire Protection: SPRINKLERS/AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $717.63 2008 Date: 6 //.3//.� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the • -rformance of work. I am authorized to sign and obtain this electrical permit. / , Signature: .7...'',-- % ''''/�� Date: 2 _Y' Print Name: AZ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL1 3-0323 Printed: 04-11-2013 411)__ PERMIT CONDITIONS Permit No. EL 13-0323 **ELECTRICAL** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL13-0323 Printed: 04-11-2013 CITY OF TUKWI1110 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No.013 �� t3 —0414 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 100 Southcenter Mall Nordstroms Tenant Name: Nordstroms I-ruititude g - 2-t`l- QED t? Suite Number: Floor: New Tenant: ❑ Yes Property Owners Name: ‘44,/`7��`V�/ / 1J Mailing Address: QVr��/yoc 004\* No C*`Mo Oft 2-0( 3 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued 3627 oSl'I Name: Matt Snyder Mailing Address: 900 N 34th St Suite 104 Seattle Wa 98103 E -Mail Address: Matts@titanelectric.net Day Telephone: 206-457-4005 City State Fax Number: 206-374-2128 Zip ELECTRICAL CONTRACTOR INFORMATION lei 2-V ' Company Name: Titan Electric Mailing Address: 900 N 34th St #108 Seattle Wa 98103 City Contact Person: Matt Snyder State Day Telephone: 206-457-4005 E -Mail Address: Matts@titan electric.net Fax Number:. 206-374-2128p, Contractor Registration Number: X92803'tit/reCt S Expiration Date: '4 1 Zip 2 -1/ Valuation of Project (contractor's bid price): $ $28,000 Scope of Work (please provide detailed information): Install lights and outlets for Juice bar in Nordstroms Will service be altered? ❑ Yes 21 No Adding more than 50 amps? [ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Property Served by: • Puget Sound Energy ❑ Seattle City Light H:\Apphcauons\Forms-Applications Un Line\4-20U7 - Electncal Perma Application.doc Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) O Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) O Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea O Meter/mast repair $65.00 O Low voltage systems $55.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $58.00 O Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) O Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR E C ' •j CAL CONTRACTOR: Signature: Date: 4/4/13 Print Name: M - tt ny • er Day Telephone: 206-457-4005 Mailing Address: 900 N 34th St Seattle,Wa 98003 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Forms-Applications On Line\4-2007 - Electrical Permit Application.doc Page 2 of 2 411 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0323 Address: 100 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/04/2013 Applicant: FRUITITUDE Issue Date: Receipt No.: R13-01219 Payment Amount: $717.63 Initials: JEM Payment Date: 04/04/2013 12:49 PM User ID: 1165 Balance: $0.00 Payee: TITAN ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 14985 717.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 574.10 000.345.832.00.00 143.53 Total: $717.63 Drinleri• Ad_Ad_9111Z 3 INSPECTION RECORD Retain a. copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ._ 6/3-0z3 (fs Project:P fi Type of Inspection: oo Address: Date Called: Instructions( Date Wanted:. 5"3I am� (P'11_1,;•Special Requester: Phone No: Approved per applicable codes. Ei Corrections required prior to approval. /- OMMENTS: Date: /3t/t3 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 rj_(206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: / tj 1 it Tql)e Type of Inspection: 7 3 Address: . Amit, /00 q Date Called: Special Instructions: Date Wanted: u a . • • Requester: Phone No: fpApproved per applicable codes. 0 Corrections required -prior o approval. COMMENTS: 1/ - west LAJ-I4 101fil edodielf Inspector: Date: oct REINSPECTION FEE REQUIRED. Prior to next inspection.fee rnuSt:be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule'reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. th3o3» PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6-300 Southcenter Blvd., #100, Tukwila. WA 98188 ' (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Jtri n1 b( Type of Inspection: 700,7 Address:j / oo rfrilt. Date Called: ...- Instructions: Date Wanted:. 5 -/Special �� m. P• Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 Li et9 deK, 6t+J v ArrID epee( r_6-11-441 kd / Inspector: JJ Date: vs/oz./II n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. •ERMIT COORD COP" - PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0323 DATE: 04/04/13 PROJECT NAME: FRUITITUDE SITE ADDRESS: 100 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: o .oi. (,17 ileilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 04/09/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/07/13 Approved ❑ Approved with Conditions 4, Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Pr ter Friendly Page • Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company TITAN ELECTRIC INC 2066332811 900 N 34Th Ste 108 Seattle WA 98103 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602250925 Active TITANEI9630B Electrical Contractor 9/2/2004 9/2/2014 General Unused Other Associated Licenses License NameType Effective Date Specialty 1 Specialty 2 Effective Date Expiration Date Status TITANE'986Q5 TITAN ELECTRIC Electrical Contractor General Unused 11/25/2002 11/25/2004 Archived Electrical Administrator INFORMATION License CROOKT"011 PB Name CROOK, TRAVIS Status Active Business Owner Information Name Role Effective Date Expiration Date FUNG, LAWRENCE 11 Agent 09/02/2004 Bond Amount BURKE, PATRICK D President 09/02/2004 9808431 FUNG, LAWRENCE H Secretary 09/02/2004 ELECTRICAL CITATION CROOK, TRAVIS J Vice President 09/02/2004 COLONIAL AM CAS & SURETY OF MD Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Lexon Ins Co 9808431 08/03/2011 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.0008/08/2011 $250.00 1 COLONIAL AM CAS & SURETY OF MD LPM4066933 08/03/2004 Until Cancelled 08/03/2011 $4,000.0008/10/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00416 8/10/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EREEB00206 2/20/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ECHAE00321 8/25/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 04/11/2013 ELECTRICAL LEGEND S /� I>• T1 LOW VOLTAGE WIRING. ##10 AWG MINIMUM MANUFACTURED WIRING SYSTEM MC CABLE, CONCEALED WHENEVER POSSIBLE CONDUIT CONCEALED ABOVE CEILING, AT STRUCTURE IN SLAB OR IN WALL. HASH MARKS INDICATE NUMBER OF CONDUCTORS. CONDUIT CONCEALED BELOW FLOOR IN FLOOR SLAB OR IN GRADE. HASH MARKS INDICATE NUMBER OF CONDUCTORS. EMCS SENSOR CABLE LOW VOLTAGE LIGHTING TRANSFORMER RECESSED DOWNLIGHT ADJUSTABLE LOW VOLTAGE DOWNLIGHT PENDANT FIXTURE WALL SCONCE RECESSED FLUORESCENT FIXTURE. • EMERGENCY EGRESS LIGHT. 010 S SaSb S3 SK TP v v 1 L v ..D SM Q. Ox 0 0 a -- f BG G WALL MOUNTED EXIT LIGHT. PROVIDE ARROWS AS NEEDED. SWITCH. +46" AFF UNLESS NOTED OTHERWISE. MOUNT ABOVE WAINSCOT WHERE WAINSCOT OCCURS. TYPICAL FOR ALL SWITCHES. ZONES A,B LIGHT SWITCHES, SUBSCRIPT INDICATES ZONE. THREE-WAY SWITCH KEYED SWITCH. SIMPLEX RECEPTACLE DUPLEX RECEPTACLE TAMPER -PROOF DUPLEX RECEPTACLE FOURPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE, PROVIDE NEMA CONFIGURATION TO MATCH PLUG. EQUIPMENT CONNECTION . DISCONNECT,.: NON-FUSED MANUAL MOTOR STARTER WITH THERMAL UNITS JUNCTION BOX, 4" SQUARE ELECTRICAL PANEL OR EQUIPMENT CABINET AS NOTED. VOLUME CONTROL. PROVIDE 4" SQ. JUNCTION BOX WITH (2) GANG MUD RING AT 46" AFF. RECESSED A.C.T. CEILING SPEAKER. SUBSCRIPT DENOTES ZONE 6.5" COAXIAL SPEAKER. SUBSCRIPT DENOTES ZONE TEMPERATURE SENSOR +66", FURNISHED BY EMCS/PSF, INSTALLED BY ELECTRICAL CONTRACTOR.. CORDINATE EXACT MOUNTING LOCATION TO AVOID CONFLICTS WITH CASEWORK, FURNITURE, ARTWORK,ETC. LINE VOLTAGE THERMOSTAT CEILING MOUNTED COMBINATION HORN/ STROBE, RECESSED. DUCT SMOKE DETECTOR FIXED TV CAMERA CABLE DROP ABOVE CEILING. SECURITY VIDEO CABLE INSTALLER SHALL PROVIDE SPECIFIED CABLES FROM CAMERA LOCATION TO THE SPECIFIED LOCATION. CAMERA. INSTALLER WILL TERMINATE CABLES. SEE DETAIL ON SHEET RE2.1 SECURITY ALARM CONTACT (RECESSED) SECURITY GLASS -BREAK SENSOR TELEPHONE OUTLET. LABEL INDICATES NUMBER OF VOICE LINES AT DEVICE. TELEPHONE OUTLET WITH WALL MOUNTING BRACKET: LABEL INDICATES W NUMBER OF VOICE LINES AT -DEVICE.. ALLOW 4" CLEARANCE ON. ALL 4 SIDES OF BRACKET FOR FUTURE -PHONE INSTRUMENT INSTALLATION. 47 COMBINATION DATA/VOICE. OUTLET WITH (1) DATA JACK AND (1) VOICE JACK. LABEL INDICATES NUMBER OF DATA AND VOICE LINES AT DEVICE. DATA/VOICE OUTLET/FOURPLEX RECEPTACLE/DUPLEX RECEPTACLE GROUP. FLUSH POKE-TH:RU DEVICE WITH INTERGRAL DEVICES AS SHOWN. GENERAL LIGHTING NOTES 1. MOUNTING LOCATIONS OF ALL FIXTURES TO BE COORDINATED AND VERIFIED WITH. ARCHITECTURE & LIGHT PRIOR TO INSTALLATION. REFER TO ARCHITECTURAL PLANS, DETAILS AND ELEVATIONS FOR MOUNTIN:G INFORMATION. ELECTRICAL CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY ON SITE CONFLICTS WITH EXISTING CONDITIONS, 2. ALL FIXTURES SHALL BE PROVIDED BY CONTRACTOR UNLESS OTHERWISE NOTED. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING MOUNTING HARDWARE FOR CEILING TYPE AND FOR ORDERING ALL PARTS NECESSARY FOR A COMPETE SYSTEM. 3, EACH FIXTURE/LAMP COMBINATION SHALL HAVE A PROTECTIVE GLASS COVER THAT COMPLIES WITH LOCAL SAFETY AND HEALTH CODE REQUIREMENTS. 4. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL DIMMING SYSTEM. LETTERS "a", "b", "c"... INDICATE LIGHT FIXTURE CONTROL GROUPING/ZONE. CONTRACTOR SHALL ENSURE COMPATIBILITY BETWEEN LIGHT FIXTURES AND CONTROL DEVICE AND VERIFY / COORDINATE LOCATION OF CONTROL DEVICES WITH OWNER AND ARCHITECTURE & LIGHT PRIOR TO INSTALLATION. FOR TECHNICAL QUESTIONS REGARDING LIGHTOLIER MULTISET PRO DIMMING SYSTEM, CONTACT MANUFACTURER DIRECTLY. LIGHTOLIER CONTROLS TECHNICAL SUPPORT 1.800.5262731. 5. MANUFACTURER LABELS SHALL NOT BE VISIBLE FROM THE FLOOR FOR ANY LIGHT FIXTURES. 6. HOMERUNS MAY BE COMBINED IN ACCORDANCE WITH NEC DERATING. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT - NO SHARING OF NEUTRAL ALLOWED. J -BOXES SHALL BE ACCESSIBLE BUT SHALL NOT BE FLUSH IN THE CEILING - NO COVERPLATE ON CEILING ALLOWED. 7. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ACCESSIBLE REMOTE TRANSFORMERS WHERE REQUIRED AND CONTROL AS SHOWN: CONTRACTOR TO ACCOUNT FOR VOLTAGE DROP AND ENSURE COMPATIBILITY OF TRANSFORMER WITH CONTROL DEVICE. SEE SPECIFICATION CUT SHEET FOR MORE INFORMATION. VERIFY ADEQUATE VENTILATION IS PROVIDED FOR EACH TRANSFORMER AND REFER TO MANUFACTURER'S WIRE SIZE CHART TO PREVENT VOLTAGE DROP. 8. LOW VOLTAGE SYSTEMS SHALL BE PROTECTED FROM OVERLOAD WITH A FUSE OR CIRCUIT BREAKER ON THE SECONDARY SIDE OF THE TRANSFORMER. 9. CONTRACTOR SHALL VERIFY VOLTAGE OF ALL BALLASTED FIXTURES. 10. NOT USED. 11. PROVIDE TO THE SITE, A MINIMUM OF (3) EXTRA LAMPS OF EACH TYPE. 12. PROVIDE TO THE SITE, (5) EXTRA LENSES OF EACH TYPE SCHEDULED ON THE DRAWINGS. 13. E.C.. TO MAKE AVAILABLE 2 ELECTRICIANS WITHIADDERS DURING FINAL ARCHITECT SITE VISIT TO ASSIST WITH AIMING OF LIGHTS. A4 A4 A4 FjA4 A4I A4 . Ao. 4, A4! PARTIAL THIRD FLOOR il MEZZANINE PLAN (N) GAS WATER HEATER (N) CIRC. PUMP SCALE: 1/8"=1'-0" SCALE: 1 /8"=1'-0" GENERAL POWER NOTES 1. PROVIDE ALL ROUGH -IN BOXES AND RINGS, CONDUIT,CONDUIT FITTINGS AND CONDUCTORS SUITABLE FOR CONNECTION OF THE EQUIPMENT AS SCHEDULED. PROVIDE RECEPTACLES AND COVERS AND MAKE FINAL CONNECTIONS INCLUDING INSTALLATION OF CORD SETS FOR HOOK UP OF THE EQUIPMENT. EACH ITEM SHALL BE FULLY CONNECTED AND FUNCTIONAL. 2: REFER TO JUICE BAR EQUIPMENT DRAWINGS AND COORDINATE EXACT LOCATION:S OF EQUIPMENT WITH JUICE BAR CONTRACTOR PRIOR TO ROUGH -IN:. 3. ALL EXPOSED CONDUIT SHALL BE MINIMUM 1/2" RIGID METAL WHERE STUBBED UP FROM FLOOR AND 1/2" LIQUID -TIGHT FLEXIBLE METAL WHEN HARD -WIRING TO EQUIPMENT TERMINAL ENCLOSURES. 4. ALL 20 -AMP, 120V RECEPTACLES AT JUICE BAR SERVICE LINE SHALL BE GROUND FAULT CIRCUIT INTERRUPTER (GFCI) TYPE. 5. ALL BRANCH CIRCUIT CONDUIT SHALL HAVE GROUND WIRE IN ADDITION TO CIRCUIT CONDUCTORS SHOWN. ENERGY CODE COMPLIANCE NOTES: 1. THIS BUILDING AND ITS NEW LIGHTING AND ITS CONTROL SYSTEMS HAVE BEEN DESIGNED TO COMPLY WITH THE ENERGY CODE ENFORCED BY THE LOCAL AHJ. CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT INSTALLATION OF ENERGY CONSERVATION MEASURES. 2. LIGHTING CONTROLS COMMISSIONING AND COMPLETION REQUIREMENTS: TEST ALL NEW LIGHTING CONTROLS TO ENSURE THAT THEY HAVE BEEN INSTALLED AND FUNCTION PROPERLY, EFFICIENTLY AND CAN BE MAINTAINED IN ACCORDANCE WITH CONTRACT DOCUMENTS AND OPERATIONAL REQUIREMENTS PER THE ENERGY CODE ENFORCED BY THE LOCAL AHJ. ENERGY SUMMARY (INTERIOR} NEW WATTAGE: 31413 DEMOLITION WATTAGE: -75135 TOTAL: -43722 FIXTURE CHANGE SUMMARY (INTERIOR} a) NUMBER OF EXISTING FIXTURES TO REMAIN: 3289 308 324 9.00 b) NUMBER OF FIXTURES DEMOLISHED: e) NUMBER OF NEW FIXTURES: PERCENT CHANGE Ect(a+b»: WASHINGTON STATE ENERGY CODE COMPLIANCE - INTERIOR LIGHTING 0 LESS THAN 60% OF THE LIGHTING FIXTURES ARE NEW. 0 INSTALLED WATTAGE IN NOT INCREASED. II SPACE USE HAS NOT CHANGED. SEPARATE PERMIT REQUIRED FOR: ra Mechanical D Electrical tel Plumbing t1'Gas Piping City of Tukwila BUILDING DIVISION L3 REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC APR 10 2013 City of. iia BUILDING ISION Q 2012 ARCHITECTURE & LIGHT DARRELL HAWTHORNE MARK R STEVENS GOIMMUNIMINEMMEIMMI BRADY' STREET SAN P R A N: C! S C o C A L I f o R N I A 94103 iei 415.678.3999 fox 415.397.4375 otlic000rohilealureaad1101.coae 1 CONSULTANT: HARGIS ENGINEERS, INC. 600 Stewart Street, Suite 1000 Seattle, WA 98101 T 206 448 3376 F 206 448 4450 www.hargis.biz J Q 00 LO 2 00 M0Ce00 LU Z Lu ZU �0pt _ O-D� Z 0Y O ISSUED FOR: PERMIT/BID SET 02.11.13 FILE COPY penult No.U, Plan review approval Is subject to effafl and om sions. Approval of construction documents does` the violation of any adopted code or ordinance. Receipt Of approved Heid Copy andaondltbro Isaclmowiedged: EXISTING GAS WATER HEATER TO BE REMOVED. SAFE -OFF ALL ELECTRICAL CONNECTIONS. EXISTING FLUE WITH IN-LINE. EXHAUST FAN TO BE REMOVED. SAFE -OFF ALL ELECRICAL CONNECTIONS. PARTIAL THIRD FLOOR PLAN SCALE: 1/8"=1`-0" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SHEET INDEX JE1.0 JE2.0 JE2.1 JE3.0 JE4.0 City Of BUILDING DbMSIkwlla ON KEY PLAN: NORDSTROM005 LEVEL 3 AREA.OF WORK X DATE: N Feb. 11, 2013 JOB NO.: 2012.040 SCALE: AWING TITLE: . RECEIVED CITY OF TUKWILA APR 0 4 2013 PERMIT CENTER ELECTRICAL LEGEND AND NOTES JUICE BAR PLAN - LIGHTING JUICE BAR PLAN - POWER ONE LINE DIAGRAM PANEL SCHEDULES ELECTRICAL LEGEND AND NOTES SHEET NUMBER: JE1.0 1. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT. 2. ELECTRICAL CONTRACTOR SHALL VERIFY MOUNTING HARDWARE PRIOR TO RELEASING ORDER_ 3. CONTRACTOR SHALL PROVIDE REMOTE TRANSFORMER AND ALL ASSOCIATED LOW VOLTAGE WIRING, CONNECTORS AND FUSING. 4. CONTRACTOR SHALL VERIFY SPECIFICATION ABOVE AND SUPPLY AND INSTALL ALL NECESSARY COMPONENTS TO PROVIDE A COMPLETE WORKING SYSTEM. 5. CONTRACTOR SHALL COORDINATE LENGTH OF FIXTURE RUNS WITH ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS. 3G-11 +48" AFF------- -.1411 FF------- ® �I a b c 'LIGHTOLIER' DIMMER (TYPICAL) SEE SCHEDULE, THIS SHEET. U U TO LIGHTING ZONES a,bAND c. NOTES: MOUNT ALL DIMMERS IN WALL BOXES AS RECOMMENDED BY 'LIGHTOLIER'. PROVIDE A SINGLE, MULTI -GANG SCREWLESS FACEPLATE FOR ALL DIMMERS IN CONTIGUOUS ROWS. IT SHALL NOT BE ACCEPTABLE TO REMOVE ANY HEATSINK FINS FROM ANY DIMMERS. REFER TO ELECTRICAL DEVICE/COVER PLATE LEGEND ON SHEET JE2.1. DIMMING CONTROL EQUIPMENT ELEVATION NOT TO SCALE DIMMER ZONE/CIRCUIT SCHEDULE :6. .Y• v Ste, n _ "CS ,11 y'r ' N 4 x% rgl,ir ,.`�1�,.� ? ra' ao t. �. :;t; .f F -- _ ai ■■( PST 1 t_ � '.: •viz_ a .c.4: � ire_ 'f' r «'�..'•r'N'^fir �"' . � LOAD (VA) QA TOTAL QTY. TAG MANUFACTURER LENS & ACCESSORIES DESCRIPTION LAMP LAMP QTY. BALLAST / TRANSFORMER FIXTURE WATTS NOTES 12 BFI LIGHTOLIER 22SS6WH AL2HC LOUVER MR16 TRACK HEAD MOUNTED ON EXISTING LYTESPAN LIGHTING TRACK. OSRAM-SYLVANIA 37MR16/IR/NFL25/C (1) INTEGRAL ELECTRONIC TRANSFORMER 37 4 BF2 LZF SUSPENSION SPRO SG, EXTERIOR 29 GREY, INTERIOR 25 ORANGE N/A DECORATIVE PENDANT WITH GREY WOOD EXTERIOR, ORANGE WOOD INTERIOR,DIMMABLE 14W. T5 LINEAR FLUORESCENT (6) ADVANCE MARK 10 DIMMING BALLASTS 84 1,2 8 BF3 LIGHTOLIER RES2-BTC. 6 - K{ 4.4 SKYTEXLINEAR FILTER 992 STEM SUSPENDED TRACK LIGHTING SYSTEM WITH ADJUSTABLE PENDANT FIXTURES OSRAM-SYLVANIA 37MR16/IR/SP10/C (1) - 37 1,2,4 - BF4 AION LED 4024-XW28-PS RC -L MOUNTING TRACK LED STRIP LIGHT MOUNTED UNDER COUNTER, DIMMABLE. DO NOT INSTALL LENS. LED (INCLUDED) - - 1.5 W/FT 2,3,4,5 - BF3 TRACK LIGHTOUER BT2I-505-AL (TOTAL LENGTH OF 21') NIA LOW VOLTAGE RAIL LIGHTING TRACK N/A - 300W TRANSFORMER TST 300 - 1,2,3,4 1. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT. 2. ELECTRICAL CONTRACTOR SHALL VERIFY MOUNTING HARDWARE PRIOR TO RELEASING ORDER_ 3. CONTRACTOR SHALL PROVIDE REMOTE TRANSFORMER AND ALL ASSOCIATED LOW VOLTAGE WIRING, CONNECTORS AND FUSING. 4. CONTRACTOR SHALL VERIFY SPECIFICATION ABOVE AND SUPPLY AND INSTALL ALL NECESSARY COMPONENTS TO PROVIDE A COMPLETE WORKING SYSTEM. 5. CONTRACTOR SHALL COORDINATE LENGTH OF FIXTURE RUNS WITH ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS. 3G-11 +48" AFF------- -.1411 FF------- ® �I a b c 'LIGHTOLIER' DIMMER (TYPICAL) SEE SCHEDULE, THIS SHEET. U U TO LIGHTING ZONES a,bAND c. NOTES: MOUNT ALL DIMMERS IN WALL BOXES AS RECOMMENDED BY 'LIGHTOLIER'. PROVIDE A SINGLE, MULTI -GANG SCREWLESS FACEPLATE FOR ALL DIMMERS IN CONTIGUOUS ROWS. IT SHALL NOT BE ACCEPTABLE TO REMOVE ANY HEATSINK FINS FROM ANY DIMMERS. REFER TO ELECTRICAL DEVICE/COVER PLATE LEGEND ON SHEET JE2.1. DIMMING CONTROL EQUIPMENT ELEVATION NOT TO SCALE DIMMER ZONE/CIRCUIT SCHEDULE ZONE NO. 'LIGHTOLIER DIMMER UNIT CIRCUIT NO. LOAD (VA) a MHP600EB 3G-11 336 b MHP600VA 3G-11 300 c MHP600VA 3G-11 42 1 `O UN`DEROOUNYER LED DRIV'E`R-SEE-SI4EET--SE 1.2 IFOR 9ONTIt1UATII'JN. 'LIGHTOLIER' TST-300 300W. REMOTE TRANSFORMER AT STRUCTURE ABOVE. i - A BF3 BF3 BF3 BF3 BF3 REMOVE ALL EXISTING TRACK LIG TING FIXTURES FROM THIS EXI TING RUOF LIGHTOLIER �4N T CK BETWEEN COLUMNS E AND G (®A AND ®)• RETURN ALL IXTURE-S-T-O-OWNER. }'14GHT-E L4ER' U2435-0-1 DIMMING PO ER EXTEND R. . IE UNT-FO-D LOW..O NTER.._ CASEWORK. 0 DOWN S'C� I1 ' 0 111 '11 11 din I j I LIGHTING PLAN SCALE: 1/4"=1'-0" REVIEWED.I-Ut COMPLIANCE WITH NFPA 70 - NEC APR 10 2013 City of Tukwila BUILDING DIVISION U 2012 ARCHITECTURE & LIGHT OARRELL HAWTHORNE MARK R STEVENS A''; R CHI . T';, C ,C '; T 60 ORAOY STREET SAN FRANCISCO CALIFORNIA 94103 tat 4 1 5. 6 1 6. 3 9 9 9 tax 4 1 5. 3 9 1. 4 3 7 5 ottico@archtt9cturaond119ht.com CONSULTANT: HARGIS ENGINEERS, INC. 600 Stewart Street, Suite 1000 Seattle, WA 98101 T 206 448 3376 F 206 448 4450 www.hargis.biz J J LO 2 co � 0 oo O ct w • w Q �w� Uw QV=- D O l— Z D R O(� � o ~ 0 ISSUED FOR: PERMIT/BID SET 02.11.13 KEY PLAN: NORDSTROM 005 LEVEL 3 AREA OF WORK— \t J N DATE: Feb. 11, 2013 JOB NO.: 2012.040 SCALE: DRAWING TITLE: JUICE BAR PLAN - �' 032._ 3 LIGHTING RECEIVED CITY OF TUKWILA APR 0 4 2013 PERMIT CENTER SHEET NUMBER: JE2.0 EQUIPMENT SCHEDULE ITEM NO. DESCRIPTION VOLTAGE PHASE AMPS MOUNTING HEIGHT CONNECTION TYPE/REMARKS 1 REFRIGERATED DISPLAY CASE 120 1 15.2 12" NEMA 5-20R 2 CASH REGISTER .120 1 .2.0 20" NEMA 5-20R 3 UNDERCOUNTER REFRIGERATOR 120 1 5.5 12" NEMA 5-20R 8 UNDERCOUNTER REFRIGERATOR 120 1 5.5 12" NEMA 5-20R 12 UNDERCOUNTER DISHWASHER 120/208 1 37.7 12" FOUR WIRE HARDWARED CONNECTION 13 BLENDER 120 1 15.0 40" NEMA 5-20R 14 INSTA-HOT WATER DISPENSER 120 1 10.8 12" NEMA 5-20R 16 DROP-IN ICE CREAM . FREEZER 120 1 6.3 12" NEMA 5-20R 18 GRINDER 120 1 6.0 40" NEMA 5-20R 19 ESPRESSO MACHINE 208 1 16 40" SEE NOTE El BELOW. / 414r_:,I)f .1') NOTES: El. ELECTRICAL CONTRACTOR SHALL PROVIDE CORD, RECEPTACLE AND PLUG FOR EQUIPMENT. ELECTRICAL DEVICE/COVER PLATE LEGEND LOCATION DEVICE FINISH COVER PLATE FINISH PLASTIC LAMINATE WAINSCOT DARK BROWN DARK BROWN VINYL WALL COVERING IVORY IVORY STAIN GRADE MILLWORK DARK BROWN DARK BROWN GRANITE DARK. GRAY DARK GRAY SERVICE LINE & KITCHEN BLACK STAINLESS STEEL P.O.S. RECEPTACLES IVORY IVORY VIDEO CABLING J -BOX / DBS RECEIVER I� 000 0 DVD PLAYER O VIDEO EQUIPMENT NOTE: LOCATE EQUIPMENT IN MILLWORK BELOW POS EQUIPMENT. MOUNTING BRACKET LCD DISPLAY frOn 11011 11011 I101I .11011 II II / CENTERLINE OF DISPLAY. L- c 1,111 u lI / 11 -- 7---- r--------------- 91 11 II 0 15"—H Asa 1 ---6'-0" AFF RECEPTACLE I�I� —I --;<1----------- 3'-9" AFF L�_J II II Ull ® VIDEO DISPLAY JUICE BAR VIDEO EQUIPMENT ELEVATIONS NOT TO SCALE • • ell UNDERCOUNTER LED POWER SUPPLY DRIVER. 'OSRAM' OT96. MOUNT INSIDE OF CASEWORK. (CIRCUIT 3G-11). JE R. S CO K1-14,16 3 #6, 1 # 00 T IO RD., 11 MOUNT RECEPTACLE HORIZONTALLY AT +39" IA 0 K-16,17,22,3 2E-4 11C �© E-4 ...............T...T...Raiiii'..C�iiii'i...:......:.7�,::.. -� lir 111 lf► il►t -r in K1-9,17- Aro 0 N. 4� K1-13,15gmli.i i iiPAIRARAI _A -- 3G-9,13 0 K-22 PH1-1-5-06 VH1-1-5-07 23 O SH1-2-1-07 1" C. K-38-,40,42- 111111"40111111111 4-3&48,42- mom is E -----7 POWER PLAN SCALE: 1/4"=1'-0" FLAG NOTES RECESSED COMMUNICATIONS OUTLET. ELECTRICAL CONTRACTOR SHALL PROVIDE PLASTER RING FLUSH WITH WALL WITH ONE PULL STRING FOR EACH COMMUNICATIONS CABLE REQUIRED TO SERVE OUTLET. DATA/VOICE CONTRACTOR SHALL RUN CABLES FROM OUTLET LOCATION CONTINUOUS TO PATCH PANELS LOCATED AT THE NEAREST DESIGNATED HCI, HC2 OR MC DATA CABLES SHALL RUN EXPOSED IN CEILING SPACE SUSPENDED AS INDICATED PER SPECIFICATIONS. SEE DETAIL #1, SHT. E-303 OF MAIN STORE ELECTRICAL DRAWINGS. T4SURVEILLANCE VIDEO SPECIFIED CABLE COILED ABOVE CEILING. (1)ATA/VOICE CONTRACTOR SHALL RUN CABLES CONTINUOUS TO DESIGNATED LOCATION CABLES SHALL RUN EXPOSED IN CEILING SPACE SUSPENDED AS INDICATED IN SPECIFICATIONS. SEE DETAIL #5 ON SHEET E-301 OF MAIN STORE ELECTRICAL DRAWINGS. EL REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC APR 10 2013 City of Tukwila BUILDING DIVISION C) 2012 ARCHITECTURE & LIGHT DARRELL HAWTHORNE MARK R STEVENS C ,. 1/ 1 E C T G H ¢ T, 60 ERADY STREET SAN FRANCISCO CALIFORNIA9 4 1 0 3 tel 415.676.3999 t o x 4 1 5. 3 9 7. 4 3 7 5 offlee@orchilectureortdllpht.eom CONSULTANT: HARGIS ENGINEERS, INC. 600 Stewart Street, Suite 1000 Seattle, WA 98101 T 206 448 3376 F 206 448 4450 www.hargis.biz J Lcg 2 °3 z oW=J 0 I 0 O C I— O ISSUED FOR: PERMIT/BID SET 02.11.13 KEY PLAN: AREA OF WORK 1 NORDSTROM 005 LEVEL 3 N DATE: Feb. 11, 2013 JOB NO.: 2012.040 SCALE: DRAWING TITLE: JUICE BAR PLAN - 342_ 3 POWER RECEIVED CITY OF TUKWILA APR 0 4 2013 PERMIT CENTER SHEET NUMBER: JE2.1 FEEDER SCI-IEDULE (ALL CONDUIT SIZES BASED ON THHN WIRE TYPE AND COMPACT ALUMINUM -CONDUCTORS), FEEDER NUMBER - . FEEDER SIZE AMPS FEEDER NUMBER FEEDER SIZE AMPS - FEEDER - NUMBER FEEDER SIZE AMPS FEEDER NUMBER FEEDER SIZE AMPS FEEDER NUMBER AMPS FEEDER. AMPS FEEDER SIZE OCPD COND NUMBER FEEDER SIZE OCPD COND OCPD COND OCPD : COND OCPD COND OCPD COND 0 #12 CU GND. 0 4 #1/0 CU & 1 #6 CU GND. ' 4 #3/0 AL & 1.#4 AL GND. 150 150 155 0 1-1/4" C., 3 #2 CU & 1 #8 CU GND. ' 90 : n 0 ' 24/7 C., 3 #300 KCMIL CU & 1 #4 CU GND. 3" C., 3 #400. KCMIL AL & 1 #2 AL GND.(2) 250 285 (2) 2-1/2" C., 3 #300 KCMIL CU & 1 #t CU- GND. . 3" C., 3 #400 KCMIL AL & 1: #110 AL GND. 550 570 ' 540 0 (4) 3"-C., 4 #350 KCMIL CU & 1 #3/0 CU GND - (4)3-1/2" C, 4 #500 KCMIL AL & 1 #250- KCMIL AL GND. 1200 1240 1240 ' 0 #10 CU GND. 0 4 #2/0 CU & 1 #6 CU GND. 4 #4/0 AL & 1 #4 AL GND. , 175 ' 175 180 0 1-1/2" C., 4 #2.CU & 1 #8 CU GND. 90 , 95 e 3!' C., 4 #300 KCMIL CU & 1 #4 CU GND. . 3" C., 4 #400 KCMIL AL & 1 #2 AL GND. 250 285- 270 e 2 3" C., 4 #300 KCMIL CU & 1 #1 CU GND. 2 3" C,, 4 #400 KCMIL AL & 1 #1/0 AL GND. ' 550 570 : 540 (5) 3-1/2" C. 4 #400 KCMIL CU & 1 #4/0 CU- GND. (5)-4 C., 4 #600 KCMIL AL & 1 #350- AL GND. '; 1600 ' 1'675 1700 0 ' #8 CU GND. 0 0 4 #3/0 CU & 1- #6 CU GND. 4#250 KCMIL & 1 #4 AL GND. 4 #4/0 CU & 1 #4 CU GND, 4 #300 KCML AL & 1 #2 AL GN.D. 200 225 200 2a5 230 230 01 e 1-1/2" C., 3 #1 CU & 1 #6 CU GND. -2" C., 3 #210 AL & 1 #4 AL GND. 1-1/2" C., 4 #1 CU & 1 #6 CU GND. 2" C., 4 #2/0 AL & 1 #4 AL GND. 100/12 5.11051/1350 100/121 5115/ 1'0/-130 35 0, 3" C., 3 #350 KCMIL CU & 1 #4 CU GND. ' 3" C., 3 #500 KCMIL AL & 1 #2 AL GND. Y C., 4 #350 KCMIL CU & 1 #4 CU GND. 34/2" C., 4 #500 KCMIL AL & 1 #2 AL GND. 300 300 310- 310 310 /7A VI/ 2 3"C, 3 #350 KCMIL CU & 1 #1 CU GND. 2 3" C., 3 #500 KCMIL AL & 1- #2/0 CU- GND. (2) 3" C., 4 #350 KCMIL CU & 1 #1 CU GN/ (2) 3-1/2" C., 4 #500 KCMIL AL & 1 #2/0 AL GND. 600 600 620 - 620 620 - 620 0 ,f: \ NL:7 6) 3-1/2"C., 4#400 KCMIL CU & 1 #25a KCMIL CU GND. . 6)4" C., 4 #600 KCM11- AL & 1 #400 KCMIL AL GND, 7) 4" C., 4 #500 KCMIL CU & 1 #350 KCMIL CLI GND. 7) 5" C„.4 #700 KCMIL AL. & 1 #600- KCIAL AL GND.- 2000 2500 2010 2040 2660' . 2625 0 #6-CLJ GND. 0 #4 CU GND. 0 4#250 KCMIL CU & 1 #4 CU GND. 4#350 KCMIL AL & 1 #2 AL GND. 250 300 255 250 310 310 ' e 0 1-1/7 C., 3 #1/0 CU & 1 #6 CU- GND. 2" C., 3 #3/0 AL & 1 #4 AL GND. 2" C., 4 #1/0 CU & 1 #6 CU GND. 2-1/2" C., 4 #3/0 AL.& 1 #4 AL GND. 150 150 150 155 , 150 155 0 0 3"-C., 3 #400 KCMIL CU & 1 #4 CU GND. 3-1/2" C.,- 3 #600 KCMIL AL & 1 #2- AL GND-,. 3" C., 4 #400 KCMIL CU & 1 #4 CU GND. 4" C., 4 #600 KCMIL AL & 1 #2 AL GND. 300 300 335 340 335 • 340 in 111/ 6; \ \:--/ (2) 3' C., 3 #400 KCMIL CU & 1 #1/0- CU GND. (2) 3-1/2" C., 3 #600-KCMIL AL & 1 #3/0 AL GND. - (2) 3"'C., 4 #400 KCM1L CU & t #1/0 CU GND. (214" C., 4 #600 KCMIL AL & 1- #3/0 AL GND.- - 650 650 ' 670 670 680- : ITA V Cr) , .8 8 't - 113" 3-112" C., 4 #500 KCMILCU & 1 #400 KCMIL CU GND. ' 5" C. 4 #750 KCM1L AL & 1 #600 KCMIL AL GND. 2-1/21' C., 4 #4/0 -CU & 1 #2 CU- GND. - C., 4 #300 KCMIL AL & 1 #1/0 AL GND. 3000 - , 225 3040 230 0 #2 CU GND. 0 4#350 KCMIL CU & 1 #4 CU GND. 4#500 KCMIL & 1 #2 AL GND. #t CU- GND. 41) 3/4"C„ 3 #10 CU & 1 #10 CU GND. 30 30 e 2" C., 3 #2/0 CU & 1 #6 CU GND. 2" C., 3 #4/0 AL & 1 #4 AL GND. 175 175 180 fi,;\ V , 3" C., 3 #500 KCMIL CU & 1 #3 CU GND. 3-1/2" C.,. 3 #750 KCMIL AL & 1 #1 AL GND. 350 380- /;,--A . (2)-3" C., 3 #500 KCMILCU & i #1/0 CU.' GND. (213-1/2" C., 3 #750 KCMIL AL & 1 #3/0 AL GND. - 750 760 770, Ot . 1 3:2:122g EU 88:11-APAiGai . - 250 255 250 0 #110- CU GND. 43 314"C., 4 #10 CU & 1 #10 CU GND 30 30 0, 2" C., 4 #2.10 CU & 1 #6 CU GND. 2-1/2" C. 4 #4/1/AL & 1 #4 AL GND. 175 ' 175- 180 f:A Nia/ 3-1/7C., 4 #500 KCMIL CU & 1 #3 CU GND.. 4" C., 4 #750 KCMIL AL & 1 #1 AL GND. 350- 385 V---7 _ (2 3-1/2" C., 4#500 KCMIL CU & 1 #1/(1 CU GND. ' 2.4" C.,.4 #750- KCMIL AL & t #3/0 AL GND. 750 760 770. , co (1 (1) 3-1/2" G., 4 #500 KCMIL CU & 1 #1/0 CU GND. 4" C., 4 #750 KCMIL AL 8i 1 #3/0 AL GNII. 350 38a 385 0 #2/0 CU GND. 0 3/4"C., 3 #8 CU & 1 #10 CU GND. 40 40 e 2" C., 3 #3/0 CU & 1 #6 CU GND. 200 , /7\ - (2) 2" C., 3 #3/0 CU: & 1 #3 CU. GNI/ 400 ' . 400 410 /65 \ \--/ , 3 24/2" C., 3 #300 KCMIL CU &I #2/0 CU CND, 3 3" C., 3 #400' KCM1L AL & 1 #3/0 AL GNU.- 8°13 855 810 -C) ' 2 2 3"C., 4 #256 KCMIL CU & 1 #1/0 CU GND. 3" C., 4:#350 KCMIL AL & 1 #3/0 AL GND, 500 510 500 0 #3/0- CU GND. 0 1"C., 4#8 CU & 1 #1.0 CU GND. 40 50 40 55 0 0 2" C., 4 #3/0 CU & 1 #6 CU GND. - 3" C_ 4 #250 KCMIL AL & i #4 AL GND. 2" C., 3 #4/0 CU- & 1 #4 CU GND. 2-1/2" C., 3 #300 KCMIL AL & 1 #2 AL GND. 200 225 200 205. 23a - 230 /;;\ Vj- /7\ \2-7 (2) 24/2" U., 4 #3/0 CU & 1 #3 GU UNU. (2) 3" C., 4 #250 KCMILAL & 1 #1 AL GND. (2) 2"- C., 3 #4/0 CU & 1 #2 GND. (2) 2-1/2" C., 3 #300 KCMIL AL & 1 #1/0 AL GND. 400- , . 400 410 460 0 3.3-1/2" C. 4 #400 KCMIL AL & t #3/0 AL GND. 413"-G., 4 #300 KCMIL CU & 1 #2/0 CU' GND. 3" C., 3 350#KCMIL CU & 1 #2/0 CUGND. 800 855 810 ' 930 az '2 2 3' 3" C., 4 #350 KCMIL CU& 1 #2/0 CU GND. 3-1/2" C., 4 #500 KCMIL AL & 1 #410 AL GND. 3" C„.4 #300-KCMIL CU & 1 #2/0 -CU GND. -3-112" C., 4 #400 KCMIL AL & 1- #410 AL GND; 600- 800 620 620 855 810 0 #4/0. CU GND.. 0 1"C., 3 #6 CU & 1 #8 CU GND. 0 . 4#4 CU& 1 #8 CU GND. 70 70 0 1"C., 4 #6 CU & 1 #8 CU- GND. 50 70 55 70 0 ci ) 2-1/2" C., 4 #4/0 CU & 1 #4 CU GND. 3" C., 4 #300' KCMIL AL & 1- #2 AL GND. -2-1/2" C., 3 #250 KCMIL CU & 1 #4 CU- GND 3" C., 3 #350 KCMIL AL & 1 #2 AL GND. 225• 250 230 230- 255 250 47, \ V_1/ in \''""/ 2' 2' 2 2 2-1/2" C., 4-#4/0 CU & 1 #2 GND. 3" C,4 #300 KCMIL AL & 1 #1/0 AL GND; , 2-1/2 C., 3 #250 KCMIL CU & 1 #2 -CU GND. 3" C., 3 #350 KCMIL AL & 1: #1/0 AL GND. 450 500 460 460 , 500 In Mir \`'' -(3) 3"C., 4 #350 KCMIL CU &I- #2/0 CU GND. :(3) 3-112" C. 4 #500- KCMIL AL & 1 #410 AL GND. 313 "C., 3#400 KCMIL CU & 1 #2/0 CUGND. 31 3-1/2" C. 3 #600 KCMIL AL & 1 #410 AL GND. - 900 - , 930 930 1005 - 1020 . 7rast ..N.-:-;" e".7","',A ‘::.../- 3.4" C. 4 #600 KCMIL AL & 1 #250 AL GND. 1313-1/2" C. 4 #400 KCMIL CU & 1 #310 CU GND. 5 3-1th C„.4 #400KCMIL CU & 1 #250 -CU GND. 5 4" C., 4 #600 KCMIL AL & 1 #400 AL GND.. 1000 . 1600 1005 1020 1675 1700 0 - 4 #2 CU & 1 #8 CU GND. 90 95 0 1-1/4" C., 3 #4 CU & 1 #8 CU GND O 4 #1 CU& 1 #6 CU GND. 4 #2/0 AL & t #4 AL GND. nrviog, 1..14, 110/I30 1151135 14/4" C., 4 #4 CU & #8 CU GND 70 70 (7;) 3"'C., 4 #250.KCMIL CU & 1 #4 CU GND. 3" C., 4 #350 KCMIL AL & 4 #2 AL GND. 250 -, 255 250: . /-- ' \56/ (213' C., 4#250 KCMIL CU- & 1 #2 CU GND. (2) 3" C., 4 #350 KCMIL AL & 1 #1/0 AL GND. 500 510 - 500 ;.(71)' -(3)3" C., 4 00 KCMIL CU & 1 #2/0 CU GNa. (3) 4" C., 4 #600 KCMIL AL & 1 #4/0 AL GND. .11.000000 , 1005 1020- - 1 E (E) (3) SETS OF 2" C., 3 #310 EACH. (4) SETS OF 2" C.. #310 EACH. M11.011.0.V6M06401. (E) #6 (E) MAIN_ DISTRIBUTION PANEL "MDP2" 3000 AMP, 277148CN.. 30, 4W, BRACED FOR 100.00'0 AIC (E) #1/0 (E) (3)- SETS OF 2" C., 4 #3/0 EACH. l.00A/3F (E) 60A/3P (E) 40 P (E) 50kW DIESEL GENERATOR, 277/480V -304W, OA BUS (E) 100A/3P THIRD FLOOR UPPER LEVEL & ROOF ---(E) #1/0 0 0 (E) CONCRETE -ENCASED UTILITY SECONDARY SERV(CE. (E. 400A BUS - 44=6,1 (E) PANEL DP4, 400A. MCB, 120/208V -30-4W (E) #110 (E) (E) 200E-V3P (E) #1I (E (E) <th 04 9 Z < co (E 400A BUS '" 0 tit j - Z < 0_ •.q. V) 0 (E) #1/0 (E) PANEL DP3, 400A. M(B, 120/208V -30-4W cc 12> Its X W (E) #1/0 REVIEWED FOR OMPLIANCE WITH NFPA 70 - NEC APR 1 0 2013 (E) 200 (E) 100A/3P (E) City of TulaMila BUILDING DIVISION 400A BUS 600A BUS (E) PANEL DP2, 400A, MCB, 120/208V -30-4W ELECTRICAL LOAD SUMMARY HIGH kW DEMAND LOAD PER PSE METER NUMBER Z009855031 (August 2012)= EXISTING DEMAND LOAD PER NEC 220.87 NEW LIGHTING (CONTINUOUS c125%) NEW GENERAL POWER (Q100%) NEW MOTOR (LARGEST AT 125%A) NEW MOTORS (REMANING © 100%) NEW HEATING (100%) NEW COMPUTER LOADS (@100%) NEW RECEPTACLES (FIRST lOkVA 100%) NEW RECEPTACLES (REMAINING @, 50%) SUBTOTAL 140550 kVA / 480 *1/3 = TOTAL LOAD 822.4 kW 1546 AMPS 48973 kVA 17654 kVA 875 kVA 0 kVA 11305 kVA 22670 kVA 10000 kVA 5710 kVA 117187 kVA 141 AMPS 1687 AMPS (E) PANEL DPI, 600A. MCB, 120/208V -30-4W THIRD FLOOR _SECOND FLOOR 250kCMI.. (E) 3 SETS OF 2" C., 4 #3/0 EACH. EXISTING ONE LINE DIAGRAM NOT TO SCALE NOTES: 1. ALL ITEMS SHOWN ON THIS ONE LINE DIAGRAM ARE EXISTING TO REMAIN, EXCEPT AS NOTED OTHERWISE. 2. ALL EXISTING FEEDERS INDICATED ARE COPPER. FIRST FLOOR • RECEIVED CITY OF TUKWILA APR 04 2013 PERMIT CENTER 2012 ARCHITECTURE & LIGHT DAR.RELL HAWTHORNE MARK R STEVENS 60 BRADY STREET SAN PRANSISC0 CAL50RNIA 94103 iel 43.67.3909 fox 415.397.4375 ottIeoaeiNlectureandUebt.com CONSULTANT: HARGIS ENGINEERS, INC. 600 Stewart Street, Suite 1000 Seattle, WA 98101 T 206 448 3376 F 206 448 4450 www.hargis.biz ISSUED FOR: PERMIT/BID SET 02.11.13 KEY PLAN: NORDSTROM 005 LEVEL 3 AREA OF WORK DATE: Feb. 11, 2013 JOB NO.: 2012.040 SCALE: DRAWING TITLE: ONE LINE DIAGRAM SHEET NUMBER: JE3.0 PANEL SCHEDULE: 02/0112013 (E) PANEL '2E' PROJECT: NordstromSouthcenter CLASSIFICATION: NORMAL FED FROM: (E) DIST. PANEL'DP3' MOUNTING: PANEL GROUP VOLTAGE: 208Y/120V 30, 4 -WIRE SECTION:1 OF 1 MAINS: 100A MAIN LUGS ONLY NEUTRAL: 100% RATED AIC: 10,000: LOCATION: 2NE GROUND: ISOLATED ENCLOSURE: NEMA 1 NOTE ITEM DESCRIPTION CKT NO. BREAKER LOAD (VA) 0 LOAD (VA) BREAKER CKT NO. ITEM DESCRIPTION NOTE AMPS POLE AMPS_ POLE LTS - CAFE REG - EMPLOYEE LOUNGE 1 20 1 540 A ` 400 20 1 2 MPCS - LINGERIE X LTS - CAFE SPARE 3 20 1 B B 250 20 1 4 POS -JUICE BAR X Z SPARE 5 20 1 C C 720 20 1 6 RECEPTS. - MEWS STOCK 158 X X MPOS-INDIVIDUALIST 7 20 1 400 A 70 20 1 8 SPARE Z X MPOS - TOP SHOP 9 20 1 400 B - 20 1 10 SPARE z Z SPARE 11 20 1 C C - 20 1 12 SPARE Z Z SPARE 13 20 1 A A - 20 1 14 SPARE Z Z SPARE 15 20 1 B B 400 20 1 16 MPDS - ENCORE X Z SPARE 17 20 1 C C 20 20 1 18 SPARE Z ' X MPOS -MEN'S SHOES - 19 20 1 400 A ` 1200 20 1 20 REG - CUSTOMER SERVICE 2 XMPOS - WOMEN'S SHOES 21 20 1 400 B 20 20 1 22 SPARE Z Z ' SPARE 23 20 1 C C 20 20 1 24 SPARE Z X POS - BP SHOES 25 20 1 560 A 400 20 1 26 MPOS - POINT OF VIEW X Z SPARE 27 20 1 B B - 20 1 28 SPARE Z X MPOS - KID'S WEAR 29 20 1 400 C - 20 1 30 SPARE Z - REC - TOWN CENTER 31 20 1 360 A • 20 20 1 32 SPARE Z GAS WATER HEATER, CIRC. PUMP REC - TOWN CENTER PRINTER 33 20 1 f 1100 B - 20 1 34 SPARE Z USED REC- INDIVIDUALIST 35 20 1 360 C 400 20 1 36 MPOS - BP X USED REC - TOWN CENTER : 37 20 1 1100 A 400 20 1 38 MPOS - KID'S SHOES X SPARE LIGHTS - SAVVY ° 39 20 1 1200 B 20 - 1 40 SPACE _ _ 42 RECEPTACLE BY PANEL X 1,X LIGHTS - SAVVY - 41 20 1 1200 C 360 20 1 42 LOAD CALCULATIONS X LOAD DESCRIPTION CONN. (VA) DEMAND FACTOR CALC. (VA) MISCELLANEOUS CONTINUOUS:- EQUIPMENT & MISCELLANEOUS:- LIGHTING: LARGEST MOTOR: MOTORS: RECEPTACLE: RECEPTACLES OVER 10kVA: COMPUTER: TOTALS: 125% - 100% - 2400 125% 3000 - 125% - - 100% - 1080 100% 1080 - 50% - 9470 100% 9470 LOAD SUMMARY TOTAL CONNECTED LOAD AMPS - 125% - 400 100% 400 9680 125% 12100 - 125% - - 100% - 540 100% 540 - 50% - 45794 65% 29766 PHASE A: 5,760 VA 48 A PHASE B: 3,750 VA 31 A PHASE C: 3,440 VA 29 A TOTAL CALCULATED LOAD: 13,550 VA TOTAL CALCULATED AMPS: 38 A 12,950 13,550 NOTES: (N)=NEW CIRCUIT, NEW BREAKER; (X)=NEW CIRCUIT, EXISTING BREAKER, (Z)=RE-LABELED CIRCUIT 1. 2. 3. 4. 5. HARGIS ENGINEERS, INC. 600 STEWART ST., SUITE 1000 SEATTLE, WA 98101 PH, (206) 448-3376 FAX. (206) 448-4450 PANEL SCHEDULE : 0210112013 (E) PANEL 'K' PROJECT: Nordstrom Southcenter CLASSIFICATION: NORMAL FED FROM: (E) DIST. PANEL 'DP5' MOUNTING: FLUSH VOLTAGE: 208Y/120V 30, 4 -WIRE SECTION: 1 OF 1 MAINS: 225A MAIN LUGS ONLY NEUTRAL: 100% RATED AFC: 10,000 LOCATION: KITCHEN GROUND: EQUIPMENT ENCLOSURE: NEMA 1 NOTE ITEM DESCRIPTION CKT NO. BREAKER LOAD (VA) 0 LOAD (VA) BREAKER CKT NO. ITEM DESCRIPTION NOTE AMPS: POLE AMPS POLE 1 LTS - CAFE 1 20 1 1260 A 660 20 1 2 UC REFRIGERATOR - JUICE BAR X 1 LTS - CAFE 3 20 1 930 B 180 20 1 4 RECEPTACLE - JUICE BAR N 1 LTS - CAFE 5 20 1 1240 C . 180 20 1 6 RECEPTACLE - JUICE BAR N 1 LTS - CAFE 7 20 1 1330 A 7006 70 3, 8 (E) PANEL 'K2' 1 LTS - CAFE 9 20 . 1 900 B 8200 - - , 10 - 1 LTS- CAFE 11 20 1 1530 C 8000 - - 12 R. EC - PHONE N.W. 1 LTS- CAFE 13 20 ` 1 950 A 720 - 1 14 SHUNT -TRIP SPACE N 1 LTS - CAFE 15 20 1 840 B 1080 20 1 16 KETTLE - JUICE BAR X X RECEPTACLE - JUICE BAR 17 20 1 180 C 1368 20 1 18 SLICER AND SCALE USED 19 20 1 500 A 700 20 1 20 TRACK LTS - CAFE 2 2 USED 21 20 1 500 8 660 20 1 22 UC REFRIGERATOR - JUICE BAR X X REF. DISPLAY CASE - JUICE BAR 23 • 20 1 1824 C 1840 20 1 24 COMPACTOR 3 ICE MAKER 25 20 • 2 920 A 690 20 3 26 WALK: IN FREEZER 3 L 27 - - 920 B 690 - - 28 - 3 WALK-IN COOLER 29 20 2 794 C 690 - - 30 - X - 31 - - 794 A 1664 • 20 2 32 ESPRESSO MACHINE -JUICE BAR X X GAS WATER HEATER, CIRC. PUMP 33 20 1 400 B 1664 - - ' 34 - 1 USED 35 20 1 900 C 500 20 1 36 USED 1 USED 37 20 1 900 A 720 20 1 38 ESPRESSO GRINDER - JUICE BAR X SPARE • 39 20 1 900 B : 660 20 1 40 UC REFRIGERATOR -JUICE BAR X 1,X USED 41 20 1 900 C 756 20 1 42 ICE CREAM FREEZER -JUICE BAR X LOAD CALCULATIONS LOAD CALCULATIONS LOAD DESCRIPTION LOAD DESCRIPTION CONN. (VA) DEMAND FACTOR CALC. (VA) MISCELLANEOUS CONTINUOUS: EQUIPMENT & MISCELLANEOUS: LIGHTING: LARGEST MOTOR: MOTORS: RECEPTACLE: RECEPTACLES OVER 10kVA: KITCHEN (EQUIP = 25): TOTALS: - 125% - 400 100% 400 9680 125% 12100 - 125% - - 100% - 540 100% 540 - 50% - 45794 65% 29766 LOADS"UMMARY TOTAL CONNECTED LOAD AMPS PHASE A: 10,935 VA 91 A PHASE B: 11,320 VA 94 A PHASE 0: 12,515 VA 104 A PHASE A: 18,088 VA 151 A PHASE 8: 17,624 VA 147 A PHASE C: 20,702 VA 173 A TOTAL CALCULATED LOAD: 42,806 VA TOTAL CALCULATED AMPS: 119 A 56,414 42,806 NOTES: (N)=NEW CIRCUIT, NEW BREAKER; (X)=NEW CIRCUIT, EXISTING BREAKER, (Z)=RE-LABELED CIRCUIT 1. 20A, 6 POLE CONTACTOR "K-1" (MOUNTED IN PANEL) 2. 30A, 4 POLE CONTACTOR "K-2" 3, 4. HARGIS ENGINEERS, INC. 600 STEWART ST., SUITE 1000 SEATTLE, WA 98101 PH. (206) 448-3376 FAX. (206) 448-4450 PANEL SCHEDULE.: 02/01/2013 (E) PANEL `3G" PROJECT: Nordstrom Southcenter CLASSIFICATION: NORMAL FED FROM: (E) DIST. PANEL DP5' MOUNTING: PANEL GROUP VOLTAGE: 208Y/120V 30, 4 -WIRE SECTION: 1 OF 1 MAINS: 225A MAIN LUGS ONLY NEUTRAL: 100% RATED AIC: 10,000 LOCATION: 3NW UPPER LEVEL GROUND: EQUIPMENT ENCLOSURE: NEMA 1 NOTE ITEM DESCRIPTION CKT NO. BREAKER LOAD (VA) 0 LOAD (VA) BREAKER CKT NO. ITEM DESCRIPTION NOTE. AMPS POLE AMPS POLE REC - BRASS PLUM 1 20 1 900 A 360 20 1 • 2 REC - UPPER LEVEL STAIR AND EMCP-6 REC - BRASS PLUM • 3 20 1 900 B 360 20 1 4 REC - 4TH FLOOR BUYERS ROOM REC - BRASS PLUM 5 20 1 900 C 360 20- 1 6 REC -• 4TH FLOOR BUYERS ROOM X RECEPTS. - BP DRESSING • 7 20 1 540 A 1080 20 1 8 REC - 4TH FLOOR BUYERS ROOM X VIDEO EQUIPMENT - JUICE BAR 9 20 1 • 100 B 900 20 1 10 REC - BRASS PLUM DRESSING ROOM . X,4 LIGHTING - JUICE BAR , 11 20 1 678 • C 1080 20 1 12 R. EC - PHONE N.W. X,4 VIDEO DISPLAY -JUICE BAR 13 20 • 1 _ 500 A 720 . 26 1 14 REC - PHONE N.W. N X,4 RECEPTS. - BP SALES FLOOR 15 20 1 720 •8 720 20 1 16 REC - SOUTH WALL WORKSTATIONS X RECEPTS. - BP BACK WALL 17 20 1 • 1620. C • 600 20 1 18 PRINTER AUTO SLIDE DOOR - RESTAURANT 19 20 1 835 A 20 1 20 SPARE 2 LTS- N.W. TERRACE 21 20 , 1 . 1000 D3 1100 20 1 22 PRINTER 3 LTS- CLERESTORY 23 20 1 1000 C 1600 20 1 24 COPIER 3 LTS- CLERESTORY 25 20 1 1000 A 1100 20 1 26 PRINTER 3 LTS. - CLERESTORY 27 20 1 1000 B 720 20 1 28 REC - N.W. 3 LTS- CLERESTORY • 29 20 1. 1000 C 100 20 1 30 ROOF PTZ POWER SUPPLY X REC - BRASS PLUM TV MONITORS 31 20 1 1000 A 1000 • 20 1 32 NORDSTROM SIGN WEST 1 USED 33 20 1 900 B 1000 20 1 34 NORDSTROM SIGN WEST 1 USED 35 20 1 900 • C 1000 20 1 36 NORDSTROM SIGN WEST 1 USED 37 20 1 900 A 1000 20 1 • 38 NORDSTROM SIGN NORTH 1 USED 39 20 1 900 B 1000 20 1 • 40 NORDSTROM SIGN NORTH 1,X EF -4 41 20 1 677 C : 1000 20 1 42 NORDSTROM SIGN NORTH 1 LOAD CALCULATIONS LOAD DESCRIPTION CONN. (VA) DEMAND FACTOR CALC. (VA) MISCELLANEOUS CONTINUOUS: EQUIPMENT & MISCELLANEOUS: LIGHTING: LARGEST MOTOR: MOTORS:. RECEPTACLE: RECEPTACLES OVER 10kVA: COMPUTER: TOTALS: - 125% • 3800 100% 3800 12178 125% 15223 835 125% 1044 677 100% 677 10000 100% 10000 2160 50% 1080 5120 100% 5120 LOAD SUMMARY TOTAL CONNECTED LOAD AMPS PHASE A: 10,935 VA 91 A PHASE B: 11,320 VA 94 A PHASE 0: 12,515 VA 104 A TOTAL CALCULATED LOAD: 36,944 VA TOTAL CALCULATED AMPS: 103 A 34,770 36,944 NOTES: (N)=NEW CIRCUIT, NEW BREAKER; (X)=NEW CIRCUIT, EXISTING BREAKER, (Z)=RE-LABELED CIRCUIT 1. 20A, 6 POLE CONTACTOR "3g" 2. 20A, 2 POLE CONTACTOR "3g1° 3. 20k 4 POLE CONTACTOR "3g2' 4. 30A, 4 POLE CONTACTOR "3G-3" 5. HARGIS ENGINEERS, INC. 600 STEWART ST., SUITE 1000 SEATTLE, WA 98101 PH. (206) 448-3376 FAX. (206) 448-4450 PANEL SCHEDULE : 02/0112013 (E) PANEL `KI` PROJECT: Nordstrom Souuthcentor • CLASSIFICATION: NORMAL :FED FROM: (E) DIST. PANEL 'DP5' MOUNTING: FLUSH VOLTAGE: 208Y/120V 30; 4 -WIRE SECTION:1 OF1 MAINS: 225A MAIN LUGS ONLY - :NEUTRAL: 100% RATED • AIC:10,000 LOCATION: KITCHEN GROUND: EQUIPMENT ;ENCLOSURE: NEMA 1. NOTE ITEM DESCRIPTION CKT NO, BREAKER LOAD (VA) 121 LOAD (VA) BREAKER CKT NO. ITEM DESCRIPTION - NOTE AMPS POLE- AMPS• POLE• DISPOSER • 1 E 20 2 1300 A 2400 30 1 2 COFFEE MAKER - 3 - . - 1300 : B 1800 20 1 4 ICE. TEA DISPENSER DISHWASHER • 5 20 1 1800 C 1332 20 1 . 6 REFRIGERATED DISPLAY CASE RECEPTACLE 7 20 1 . 720 A 1800 20 1 8 HOT FOOD TABLE X JUICE BAR -INSTA-HOT WATER DISP. 9 , 20 1 - 1.296 B 3000 4+0 2 10 COFFEE URN REGISTER 11 26 1 800 C 3000 • - - . 12 - X JUICE BAR - BLENDER 13 20 1 1800 A 3921 50 2 -14 JUICE BAR - DISHWASHER N X JUICE BAR -BLENDER 15 20 1 • 1800 B 3921 - - 16 - X JUICE. BAR - UC REFRIGERATOR 17 20 1 660 • C 1400 20 • 2 18 TOASTER REFRIGERATED DISPLAY CASE 19 • 20 1 1080 A 1400 . - - ` 20 - UNDERCOUNTER REFRIGERATOR 21 20 1 480 ' B 1400 • 20 • 2 22 TOASTER UNDERCOUNTER REFRIGERATOR 23 20 1 480 , C 1400 - - 24 UNDERCOUNTER REFRIGERATOR • 25 20 1 480 A 1440 . 20 1 26 SANDWICH TABLE JUICE DISPENSER 27 20 1 1440 B 180 20 1 28 RECEPTACLE RECEPTACLE 29 20 1 500 C 1068 20 1 ' 30 LETTUCE DISPENSER/SALAD-TABLE PRINTER 31 20 • 4 • 800 A 900 20 1 32 SPINNER/MILD AND SODA DISPENSER USED 33 • 20 1 900 B 1068 20 2 34 MICROWAVE OVEN USED • 35 ' 20 1 r. 900 0 1068 - - 36 - USED ' 37 20 1 900 A 900 20 1 38 USED USED • 39 • 20 1 ' 900 B 180 20 1 40 RECEPTACLE - GIFTS 1,X HAND DRYER 41 ' 20 1 1080 C , 240 : 20 1 42 MILK DISPENSER LOAD CALCULATIONS LOAD DESCRIPTION CONN. (VA) DEMAND FACTOR CALC. (VA) MISCELLANEOUS CONTINUOUS: EQUIPMENT & MISCELLANEOUS: LIGHTING: LARGEST MOTOR: MOTORS: RECEPTACLE: RECEPTACLES OVER 10kVA: COMPUTER:: ELECTRIC HEATING: KITCHEN (EQUIP = 29): TOTALS: - 125% - - 100% - 125% - - 125% - - 100% - 1580 100% 1580 - 50% - 1600 100% 1600 _ 1080 100% 1080 50974 65% - 33133 LOAD SUMMARY TOTAL . CONNECTED LOAD AMPS PHASE A: 19,841 VA 165 A PHASE B: 19,665 VA 164 A PHASE C: 15,728 VA 131 A TOTAL CALCULATED LOAD: 37,393 VA TOTAL CALCULATED AMPS: 104 A 55,234 37x393 NOTES: (N)=NEW CIRCUIT, NEW BREAKER;. (XNEW CIRCUIT, EXISTING BREAKER, (Z)=RE-LABELED CIRCUIT • 1. PROVIDE GFI CIRCUIT BREAKER 2. 3. 4. 5. HARGIS ENGINEERS, INC, 600 STEWART ST., SUITE 1000 . SEATTLE, WA 98101 PH:. (206) 448-3376 FAX. (206) 448-4450 REVIEWtu i•L�rr COMPLIANCE WITH NEPA 7A - NEC APR 10 2013 City of Tukwila BUILDING DIVISION SLI',- 0 3�.3 NOTE: JUICE BAR PROJECT IS TO BE BUILT CONCURRENTLY WITH NORDSTROM SOUTF-ICENTER STORE REMODEL PROJECT. ONLY CIRCUITS INDICATED ON THE PANELS ABOVE, NOTED AS BEING ASSOCIATED WITH THE JUICE BAR, SHALL APPLY TO THIS PROJECT. RECEIVED CITY OF TUKWILA APR 0 4 2013 PERMIT CENTER 2E K 3G K1 PANEL SCHEDULE KEY PLAN 10 2012 ARCHITECTURE & LIGHT DARRELL NAWTHORNE MARK. R STEVENS' 60 BRADY STREET S AN f RANCTSCO CALIFORNIA 94.103 141 419.676.3999 t ax 4 1 5. 3 9 7. 4 3 7 5 o iceitarchifectareaedtlQht,ccm 1 CONSULTANT: HARGIS ENGINEERS, INC. 600 Stewart. Street,. Suite 1000 Seattle, WA 98101 T 206 448 3376 F 206 448 4450 www.hargis.biz J J In c co co 0 c a • o Ce Co LLJ W D wI < t Qit—I k 0 co I- 0 ISSUED FOR: PERMIT/BID SET 02.11.13 KEY PLAN: NORDSTROM 005 LEVEL 3 AREA OF WORK J a�N DATE: Feb. 11, 2013 JOB NO.: 2012.040 SCALE: DRAWING TITLE: PANEL SCHEDULES SHEET NUMBER: JE4.0