Permit EL13-0361 - CACHE - REMODEL
CACHE 221 S OUTH CEN1 F.R MALL EL1 3-0361 City ofI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 9202470010 Address: 221 SOUTHCENTER MALL TIIKW Project Name: CACHE ELECTRICAL PERMIT Permit Number: EL13-0361 Issue Date: 06/20/2013 Permit Expires On: 12/17/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MARGO KOZICH Address: 2136 FURCELL DR , FERNANDINA FL, 32034 Contractor: Name: OLSON ENERGY SERVICE Address: 4415 LEARY WY NW , SEATTLE WA 98107 Contractor License No: OLSONES880MT Phone: 904 491-6314 Phone: 206 782-5522 Expiration Date: 08/02/2014 DESCRIPTION OF WORK: REPLACEMENT OF EXISTING LIGHTING AND UPGRADE, NEW LOW VOLTAGE SYSTEM, STOREFRONT WITH SIGN, AND NEW WALL PLUGS. Value of Electrical: NRES: $15,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKELRS/AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: $438.13 2008 2) I hereby certify that I have read and xami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, hether specified herein or not. The granting of this pe construction or,t$e p Signature: t dogs not pre eofw Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit. 6--)fza aolf/49)ii Date: ‘, 1'03 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL13-0361 Printed: 06-20-2013 PERMIT CONDITIONS Permit No. EL13-0361 **ELECTRICAL** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL13-0361 Printed: 06-20-2013 CITY OF TUKWIfri4 Community Developmt. Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TuW ilaWA. gov 4444, Electrical Pe. + No. Project No:. . Date Application Accepted: Date Application Expires: ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: oovi/ t tAilE L Tenant Name: L"/"V/g/ King Co Assessor's Tax No.: 9.020-467-09/ a Suite Number: ‘0106) Floor: New Tenant: .... Yes PROPERTY .OWNER. Name: 1, /? C� / Name: „1,r va./t/7- 4_ /miC frtieITiCJt Address: f fiiex ✓ / h r City: 04,v flex"( State: 1 9 Zip: 90. CONTACT PERSON .=.,person receivingall project communication Name: 1, /? C� / ,r& Address :%.72 % A% City: yam_, ,e ,0404 State: Zip: Phone:g0 41,-b/ Fax: 44/-0 Email: ELECTRICAL CONTRACTOR INFORMATION Company Name: /Li,va ,O,,1/4/ Address: /711A/ C/eeoGC4 IQ City: A/V A( State: 77 Zip7�/DZ � Phonece7 / �3 `� : �/ Fax: j` 56 1/5,Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ /#/0°' Scope of Work (please provide detailed information): /7//¢a76Air 2/ 6X/�ii 4/-? UG7 NT1 /' i M14 /✓6h/ LoR) W/7"�eg•t- 7r&✓, "Ale �/�N/ 9v/9 v Will service be altered? ❑ Yes �No Type of Use: Type of work: ❑�Iew ,[]/ Addition ❑ Service Change ❑ Remodel � Tenant Improvement ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Adding more than 50 amps? ❑ Yes ❑ No Low Voltage Property Served by: ❑ Puget Sound Energy Generator ❑ Seattle City Light H \Applications\Forms-Applications On Line \2011 Applications\Electrical Permit Application Revised 8-9-11 docx Revised August 2011 bh Paget of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) O Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 O Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) O Carnivals $78.75 Number of concessions $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: City Date: Day Telephone: H \Applications\Forms-Applications On Line \2011 Applications\Electrical Permit Application Revised 8-9-11 docx Revised August 2011 bh State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 9202470010 Address: Suite No: Applicant: CACHE 221 SOUTHCENTER MALL TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: EL13-0361 ISSUED 04/18/2013 06/20/2013 Receipt No.: R13-02017 Initials: User ID: JEM 1165 Payment Amount: $63.00 Payment Date: 06/28/2013 10:06 AM Balance: $0.00 Payee: ADAM D MANGOLD TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 140454 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 Total: $63.00 63.00 a,,,.• De, a .,r_na Printed: 06-28-2013 r • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0361 Address: 221 SOUTHCENTER MALL TURIN Status: APPROVED Suite No: Applied Date: 04/18/2013 Applicant: CACHE Issue Date: Receipt No.: R13-01922 Initials: JEM User ID: 1165 Payment Amount: $350.50 Payment Date: 06/20/2013 08:09 AM Balance: $0.00 Payee: OLSON SERVICE GROUP, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 92902 350.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 350.50 Total: $350.50 o.nro,• na_�n_�n1z C* of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R13-01356 Initials: JEM User ID: 1165 Payee: COMMERCIAL PERMIT GROUP, INC. Payment Date: 04/18/2013 Total Payment: 926.30 SET ID: S000001964 SET NAME: CACHE SET TRANSACTIONS: Set Member Amount D13-122 789.69 EL13-0361 87.63 M13-070 48.98 TOTAL : 91317151-- TRANSACTION 89'r6 TRANSACTION LIST: Type Method Description Amount Payment Check 3549 926.30 TOTAL: 926.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 87.63 838.67 TOTAL: 926.30 MIMIINSPECTION RECORD Retain a copy with permit •- INSPrTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: PK-4k( �� Type of Inspection: � ®Q Address: 224 14tt_.- Date Called: Special Instructions: Date Wanted: 74.3 n Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. l COMMENTS: CaKic60-1045 �I Inspector: Date• (2)7(23113 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy' -with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 '. Project: 5c4+6A00 Type of Inspection: attAtJcl Address: ZZI ri' ` 4 Date Called: - - ot, t- S r,rtt(, 'l$ 66 A o ostr6 Special Instructions: ' Date Wanted: ca.m./ 7Z2- Requester: 646 D6Ot c A T el- G tecidi r rq-4- i R fkiaic Phone No: ElApproved per applicable codes. -Corrections required prior to approval. COMMENTS:,., Mei, '�0 �,�, l .6 e it �f/��► R - t nAlit�i►` -coCftnitrJ.s frakr IV attAtJcl - in IJ® -KAP gr. To Coij Jt— S iso C.' LjCt r- - - ot, t- S r,rtt(, 'l$ 66 A o ostr6 C9I l►(-- ,5 - akovilP (#% C,tJ'T /ol 56-tc-6L.AALD !nl 6 arr. - C L-144-7144 '7t tri 4N Lockz., Lfctv4t ci4r ,s41,65 ccozogt tort wide 646 D6Ot c A T el- G tecidi r rq-4- i R fkiaic L4ft4DIX CLf Inspector: Date: LZ t n REINSPECTION` FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit th3-o3jINSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ti (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: 003 Address:ZA t Date Called: Special Instructions Date Wanted: a. . Requester: . Phone No: Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: i�4 - 03dek soc4-ko. gotA, dooPIPL64f Date: 511(3 n REINSPECT! ' N FEE REQUIRtD. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. �, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 6U3 -v3+,( Project:VGlick � Type of Inspection: °0 / 7 Address:al A1A, Date Called. Special Instructions:1 Date Wanted: / a. ii Requester: Phone No: ElApproved per applicable codes. tl Corrections required prior to approval. COMMENTS: s"is COArmTf 70 3 Yk IL" \• 0/nth *Nip tittetouD$ Inspector: Date: 66-H,,. n REINSPECTION I EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 4PERMiT COORD PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0361 DATE: 06/20/13 PROJECT NAME: CACHE SITE ADDRESS: 221 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Building ett ion Public Works El Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 06/25/13 Not Applicable ❑ Comments: Permit Centel Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved le Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DUE DATE: 07/23/13 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: *PERMIT COORD COPS PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0361 DATE: 04/18/13 PROJECT NAME: CACHE SITE ADDRESS: 221 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 4w C Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 04/23/13 Not Applicable ❑ Comments: Permit Center Use Only - INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural'Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/21/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 0 PROJECT NAME: eikb\A SITE ADDRESS: 1/)— £C M At\ PERMIT NO: ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INIT LS 1 Oti1 \1r5i_ g 6�tit 13 ,V Summary of Revision: 4e L ()h! U a t 01 ow (A a (�I-CA I� �11Wd l �l C 0'6 Received by: 1r, nn N\!'. ar ,\ C". REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: CLi - d ,k/ O Response to Incomplete Letter # O Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: / Z/ 72/17/e6/IVT11l_ 71/4/1//L-41 I%* 9/d 2 Contact Person: 717Ae(70 ZJGi-I Phone Number: '*4-• -h3/1 Summary of Revision: ^Iry7c oft JUN 2 v 2013 �ERMII CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Centgr by: Entered in Permits Plus on Z� H: Applications\Fonns-Applications On Line\2010 Applications\7-2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7-2010 Contractors or Tradespeople P-= ter Friendly Page Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company OLSON ENERGY SERVICE 2067825522 4415 Leary Way Nw Seattle WA 98107 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 578052563 Active OLSONES880MT Electrical Contractor 8/2/2012 8/2/2014 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status OLSONES892QD OLSON ENERGY SERVICE Electrical Contractor Residential Unused 11/15/2011 11/15/2013 Re - Licensed Master Electrician INFORMATION License JOHNSC`973RJ Name JOHNSON, CHRIS Status Active Business Owner Information Name Role Effective Date Expiration Date OLSON, ROBERT A Agent 07/30/2012 OLSON, ROBERT A President 07/30/2012 OLSON-CALPE, ANNE Secretary 07/30/2012 OLSON-CALPE, ANNE Treasurer 07/30/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 Developers Surety f& Indem Co 575303C 06/10/2005 Until Cancelled $4,000.00 08/02/2012 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa.gov/lni/bbin/Print.asnx 06/20/2013 SEPARATE PERMIT REQUIRED FOR: ( lllietnanical CI Electrical [dumbing [was Piping City of Tukwila BOLDING DIVISION FILE COPY nit No, ELAS -4C2.3(9 1 n revwapprovalbsubjectto woo and onissloI Approval of construction documents Mc violation of any adopt code or ordinance. IIQI Receipt 4f approved Ind sodomisodomites�gl�d� By City Of llikwiII BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan sutttal and may include additional plan review fees. r ° ° -- 1- >_. `4NTRAL PATCHING PATCH CABLE RJ- 12 STATION NTRA CEL PATCHING PARTS LIST: 12 PORT BOX P/N 41089-12W (6) VOICE JACK P/N 41106—RL6 (6) DATA/DSL JACK IP/N 5G108—R05 AS MFG BY "LEVITON". CENTRAL PATCHING BOX "D2" TO BE INSTALLED AT ±40"AFF OVER MANAGERS DESK IN STORAGE ROOM NOT TO SCALE NOTE: ALL CABLES FROM EACH PC REGISTER WILL BE HOMERUN BACK TO THE CENTRAL PATCHING STATION LOCATED IN STORAGE ROOM. RUN IN 3/4" EMPTY METAL CONDUIT W/ PULL WIRE FOR FUTURE REGISTERS. VERIFY W/ CACHE QUANTITY OF INITIAL REGISTERS FOR OPENING. ALL DATA CABLES WILL BE TERMINATED TO EIA/TIA 5686 SPECIFICATIONS. ALL VOICE CABLES WILL BE TERMINATED TO USOC SPECIFICATIONS PATCHING BOX, JACKS, CONDUIT AND CAT CABLES — SUPPLIED AND INSTALLED BY ON SITE G.C. EQUIPMENT DEVICES, PATCH CABLES, CONNECTOR DEVICES AND HOOK—UPS — SUPPLIED AND INSTALLED BY CACHE. USER/PC PARTS LIST: 4 PORT Bax P/N 41089-4WP (1) VOICE JACK P/N 41106—RL6 (2) DATA JACKS IP/N 56108—R05 AS MFG BY "LEVITON". PHONE/MODEM RJ12 BLUE DATA RJ45 ORANGE DATA BACK—UP RJ45 ORANGE UNUSED TO CENTRAL PATCHING( STATION IN STORAGE ROOM TO EACH PC REGISTER CAT 5E FOR DATA CAT 3 FOR VOICE (MODEM OR PI-IONE) 4 PORT JAC< "Di " TO BE USED AT EACH REGISTER NOT TO SCALE EXISTING SIGNAGE CIRCUIT TO3 BE REUSED WHERE POSSIBLE. A-18 INDICATES SAW CUT CHANNEL UNDER TILE FLOOR FOR 'EXPONDER' LOOPWIRE. SURFACE MOUNTED OUTLETS & CONDUITS INSTALLED ON FACE OF PARTITION AT BACK COUNTER UNIT CABINET FOR MUSIC SYSTEM. CABINETRY CONTRACTOR TO PROVIDE 12"Hx18"W CUT—OUT PANEL FOR ACCESS AT LOCATION TBD. PROVIDE (1) CAT 5 CABLE IN 1/2" CONDUIT ABOVE CEILING FROM FRONT DOOR TO MANAGER'S DESK. RECESSED MOUNTED OUTLETS INSTALLED ON INSIDE FACE OF SIDE WRAP CABINET. FIELD VERIFY EXACT LOCATION. CABINETRY CONTRACTOR. TO PROVIDE ACCESS THRU CASH WRAP UNIT FOR TERMINAL INSTALLATION HOOK UP AND INTERCONNECTION. CORE DRILL OR SAW CUT FOR INSTALLATION OF CONDUITS. PATCH FLOOR TO MATCH SURROUNDING FLOOR AREA. COORDINATE WITH MALL;S REPRESENTATIVE TO DETERMINE LOCATION OF EXISTING UTILITIES AND TO RECEIVE LANDLORD'S PRIOR APPROVAL ROUTER. SWITCH / HUB CAT 3 CABLE SERVER PATCH CABLE RJ -45 CAT 5E CABLE PC/REGISTERS PC MODEM/PHONE. TO RJ --45 JACK / WALLPLATE TO RJ -12 JACK/WALLPLATE (RUN IN 3/4" MTL CONDUIT) DSL & TELEPHONE LI E NOTES: DAY 1 OF CONSTRUCTION: — ON—SITE G.C. TO INSTALL PLYWOOD PHONE PANEL PER PLAN -- ELECTRICAL SUB CONTRACTOR TO: RUN CONDUIT & WIRES FOR POWER, PHONE AND CAD 5 TO CASH/WRAP LOCATION JUNCTION BOX (ALL SURFACE MOUNTED) AT 60" A.F.F. PER PLAN; PHONE AND CAD 5 CABLES, TO HAVE 8 FT. COILED SLACK; AND ATTACH JACK TO END OF PHONE WIRE. BY WEEK #5 OF CONSTRUCTION: - ON—SITE G.C. TO VERIFY THAT DSL & TELEPHONE LINES ARE "UP; & RUNNING". PC / REGISTER MODEM PATCH CABLE TO RJ -45 DATA JACK PATCH CABLE TO RJ -12 PHONE/ MODEM JACK PC / REGISTER PATCH CABLE TO RJ -45 DATA JACK PATCH CABLE TO RJ -12 PHONE / MODEM JACK NOTE: ALL CABLES FROM EACH PC REGISTER WILL BE HOMERUN BACK TO THE CENTRAL PATCHING STATION LOCATED IN STORAGE ROOM. RUN IN 3/4" EMPTY METAL CONDUIT W/ PULL WIRE FOR FUTURE REGISTERS. VERIFY W/ CACHE QUANTITY OF INITIAL REGISTERS FOR OPENING. ALL. DATA CABLES WILL BE TERMINATED TO EIA/TIA 5686 SPECIFICATIONS. TRANSMIT LOOP WIRE ABOVE DOOR FRAME IN CEILING 24x24 ACCESS PANEL CONTROL UNIT IN ENTRY SOFFIT 0 TRANSMIT LOOP WIRE "XPOF\ D" LOOP SYSTEM REFER TO CODED NOTES ON PLAN NOT TO SCALE "XPO\DR" LOOP SYST POWER PLAN scale: 1/4" = 1'-0" EM NOTES 8c REQJIR M,ENTS ACCESS FOR CONTROLLER 24"x24" ACCESS DOOR PROVIDED IN ENTRY CEILING BY CACHE'S ONSITE G.C. REFER TO SPEC. DWG #E-2. DEDICATED POWER OUTLET. -- TYPE: DEDICATED, BREAKER PROTECTED CIRCUIT. — NUMBER OF OUTLETS: STANDARD 120 VAC SINGLE GANG OUTLET. -- AMPS: 15 AMP CIRCUIT BREAKER (LOW VOLTAGE CONTROL / CABLING). -- LOCATION: LOCATE OUTLET IN CEILING ON STORE SIDE WITHIN "ARMS REACH" OF THE ACCESS PANEL. — DEDICATED 24HR 120V DUPLEX RECEPTACLE PROVIDED ABOVE ENTRY SOFFIT BY CACHE'S ONSITE ELECTRICAL CONTRACTOR. — ALL RELEVANT LOW VOLTAGE PERMITS BY CACHE'S ON SITE ELECTRICAL CONTRACTOR. TRANSMIT LOOP — LOOP WIRE: "XPONDR" PROVIDED 18 AWS STRANDED WIRE FORMS CONTINUOUS LOOP AROUND EXIT—WAY. — DEPTH: LOOP WIRE IN 1/2" WIDE GROOVE BY 1" DEEP CUT IN CONCRETE COVERED WITH QUICKSET CONCRETE MIX. — LOOP ROUTING: LOOP IS RUN UP VERTICALLY & ACROSS EXIT IN CEILING SPACE TO CONTROL UNIT IN ENTRY SOFFIT. - VARIATION IN TRANSMIT LOOP WIRE RUN REQUIRED FOR STEEL COLUMNS & RED IRON. TRANSMIT LOOP WIRE CANNOT BE RUN IN, _BEHIND, OR UNDER STEEL STRUCTURE OR METAL CONDUIT. 1/2"W x 1"D LOOP WIRE SAW—CUT INTO EXISTING CONCRETE SLAB BY CACHE'S ONSITE G.C. G.C. WILL ENSURE ACCESS FOR LOOP WIRE AT BOTTOM OF VERTICAL 4"'SQ ALUMINUM ENTRY COLUMNS. RECEIVE ANTENNAS (3 ANTENNAS REQUIRED) --- DOOR FRAME TYPE: OPTIONAL ROD TYPE — FLOOR TYPE: AUTO TYPE 4 1/2" x 6 1/2" x 1 1/2"D RECEIVE CABLING: CABLE IS PVC JACKET', 22 AWG 3—CONDUCTOR, SHIELDED CABLE FIRE: UL 1581, CSA FT4 APPROVAL: CSA AWM II A/B 80C, UL NEC CM 129985 FLOOR WORK: "XPONDR" NEEDS TO BE NOTIFIED AT LEAST TWO WEEKS IN ADVANCE OF THE START DATE OF THE FLOORING OR TILE WORK. FLUORESCENT LIGHTING: SOME TYPES OF ELECTRONIC BALLASTS USED FOR FLUORESCENT LIGHTING CAN CAUSE SIGNIFICANT PERFORMANCE ISSUES FOR "XPONDR" EQUIPMENT. MAGNETIC BALLASTS ARE NOT A PROBLEM, BUT SAMPLES OF ELECTRONIC BALLASTS INTENDED FOR USE IN THE STORE MUST BE SUBMITTED TO "XPONDR" IN ADVANCE FOR TESTING. "XPONDR" CAN RECOMMEND A SUITABLE REPLACEMENT IF NECESSARY ONCE TESTING HAS BEEN COMPLETED. CEILING WORK: IF THE STORE IS NEW CONSTRUCTION OR REMODELING INCLUDES A NEW CEILING, "XPONDR" NEEDS TO HAVE ACCESS TO THE CEILING AT THE SAME TIME AS THE FLOOR WORK. PLEASE CONTACT "XPONDR" IF THE CEILING WILL BE CLOSED NEAR THE DOOR BEFORE THE FLOORING WORK BEGINS. "XPONDR" LOOP SYSTEM KEYED NOTES: 1O CONTROL UNIT INSTALLED VERTICALLY IN STORE SIDE OF ACCESS SPACE ON METAL STUD FRAMING ABOVE ENTRY CEILING WITHIN ARMS REACH OF ACCESS DOOR. INSTALLED BY "XPONDR". METAL STUD FRAMING BY G.C. COORDINATE WITH "XPONDR". © DEDICATED 24HR 120VAC DUPLEX RECEPTACLE INSTALLED ABOVE ENTRY CEILING WITHIN ARMS REACH OF ACCESS DOOR AND WITHIN 4 CABLE FEET OF "XPONDR" CONTROL UNIT BY ONSITE G.C. 0 RECESSED AUTO FLOOR ANTENNAS (3 PIECES) INSTALLED BY "XPONDR". ONSITE G.C. TO PROVIDE SAWCUT 4-1 /2"x6-1 /2"x1-1 /2" RELIEF FOR ANTENNAS IN SLAB. ® TRANSMIT LOOPWIRE (18 AWG, TEFLON JACKET) CONTINUOUS LOOP AND ANTENNA CABLE S IN SLAB TO RUN UP INSIDE ENTRY INTO OVERHEAD, INSTALLED BY XPONDR. ONSITE C.C. TO PROVIDE 1/2"Wx1"D SAWCUT FOR CONTINUOUS LOOP IN SLAB. VARIATION IN TRANSMIT LOOP WIRE RUN REQUIRED FOR STEEL COLUMNS, RED IRON. 50 DIGITAL ALARM DISPLAY WALL MOUNTED ABOVE ENTRY DOORS, INSTALLED BY "XPONDR". © ALL CABLES AND TRANSMIT LOOP WIRE TERMINATE AT CONTROL UNIT BY "XPONDR". ONSITE G.C. TO PROVIDE OPEN ACCESS AT 2 ENTRY COLUMNS FROM SLAB TO ABOVE ENTRY CEILING FOR "XPONDR" TO RUN LOOP WIRES AND OPTIONAL SIDE WALL ANTENNAE. © 24" x 24" ACCESS DOOR. REFER TO SPECS ON DWG F-2. n""'" PM TEL PYrR L ® a DI 24 HR 24HR SCHEMATIC ELEVATION STOCK ROOM MANAGER'S DESK O EXISTING AIR -HANDLING UNIT (AHD) TO REMAIN AND BE REUSED. E.C. SHALL VERIFY ALL WIRING, DISCONNECT AND CIRCUITRY IS IN GOOD WORKING ORDER AND REPAIR/REPLACE AS REQUIRED. VERIFY THERE IS AN EXISTING SERVICE LIGHT/SERVICE RECEPTACLE AND THAT IT IS IN GOOD WORKING ORDER. REPAIR/REPLACE AS NEEDED OR PROVIDE ONE IF NONE IS EXISTING. LOCATION AND CIRCUITRY SHOWN FOR REFERENCE ONLY. VERIFY ALL CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. O EXISTING WATER HEATER TO REMAIN AND BE REUSED. E.C. SHALL VERIFY ALL WIRING, DISCONNECT AND CIRCUITRY IS IN GOOD WORKING ORDER AND REPAIR/REPLACE AS REQUIRED. LOCATION AND CIRCUITRY SHOWN FOR REFERENCE ONLY. VERIFY ALL CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. • E.C. SHALL EXTEND EXISTING BRANCH CIRCUIT FEEDERS AND CONDUIT FOR EXISTING STOREFRONT SIGN TO SERVICE PANEL "A" AND RECONNECT. VERIFY COMPLETE LENGTH AND ROUTING IN FIELD. STOREFRONT SIGN TO BE CONTROLLED VIA 7—DAY TIME CLOCK. SEE DETAIL 2 ON SHEET E-2 FOR MORE INFORMATION. O EXISTING ELECTRICAL SERVICE PANEL "A" TO REMAIN AND BE REUSED. E.C. TO VERIFY SERVICE EQUIPMENT IS ADEQUATE AND IN GOOD WORKING ORDER. REPAIR/REPLACE AS NECESSARY. SEE ONE—UNE DIAGRAM ON SHEET E-3 FOR FURTHER'' INFORMATION. • TENANT SHALL CONTRACT±WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR FOR DESIGN AND PROGRAMING AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANTS EXPENSE. TENANT SHALL USE ONLYLANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. VERIFY BALL ,REQUIRED WORK PRIOR TO PLACING BID. O STORE FRONT CEILING MOUNTED RECEPTACLES TO BE CONTROLLED VIA TIMECLOCK. SEE DETAIL 2 ON SHEET E-2 FOR MORE INFORMATION. POWER & SIG AL LE SYMBOL e4 it 0 CDIG 01 D1 D2 JSPI NOT TO SCALE NOTES: DESCRIPTION END RECESSED DUPLEX ELECTRICAL CONVENIENCE OUTLET MOUNTED HORIZONTALLY AT 6 1 /2"AFF. (UNLESS OTHERWISE NOTED).` RECESSED DUPLEX ELECTRICAL CONVENIENCE OUTLET MOUNTED VERTICALLY AT + 15" AFF (UNLESS OTHERWISE NOTED) DATE: 5.26.2015 JOB NO: DRAWN: CHECKED: _ _ _ 711 N. FIELDER RD. ARLINGTON. TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC JUN 2 8 2013, City of .Tukwila BUILDING DIVISION RECESSED QUADRUPLEX ELECTRICAL OUTLET MOUNTED VERTICALLY AT + 18" AFF (UNLESS OTHERWISE NOTED) ELECTRICAL JUNCTION BOX MOUNTED AT HEIGHT AS NOTED ON PLAN ' RECESSED 3 GANG WALL BOX MOUNTED AT + 9" AFF P.O.S. TERMINAL DEDICATED CIRCUIT FOR ELECTRIC—DATA—TELEPHONE RECESSED PC REGISTER JACK. SEE DETAIL THIS DWG, CENTRAL PATCHING STATION. SEE DETAIL THIS DWG. RECESSED WALL TELEPHONE JACKS MOUNTED VERTICALLY AT HEIGHTS AS .;NOTED ON PLAN, TO BE SUPPLIED & INSTALLED BY ON SITE G.0. 5 PHONE JACKS REQ'D: SALES COUNTER ( 2 PHONE + 2 COMPUTER) STORAGE ROOM MGR. DESK (1 PHONE) STEREO SPEAKER INPUT JACK PANEL MOUNTED AT + 60" AFF RECESSED, IN WALL VOLUME CONTROL BOX TO CONTROL FITTING R001+1' AUDIO SPEAKER ONLY. "RADIO SHACK" CAT.#40-993` EXISTING RECESSED CEILING MOUNTED EXAUST FAN TOILET ROOM CEILING SURFACE MTD 1 X 4 2—LAMP FLUORESCENT LIGHT FIXTURE W/ ELECTRONIC BALLAST, ACRYLIC LENS, & T-8 3000°K LAMPS. "MERCURY LIGHTING" M 106-232—OCT—A—ELB-120V (OR APPROVED EQUAL) PUSH BUTTON BUTTON AND BUZZER "EDWARDS" #115-165 BUZZER ALL DUPLEX OUTLETS, WALL SWITCHES, DIMMER * - CONTROLS, PHONE JACKS, AND ALL EXPOSED ELECTRICAL. DEVICES TO BE INSTALLED W/ IVORY COLOR BAKELITE COVER PLATES * ALL WALL MTD SWITCHES & CONTROLS TO BE INSTALLED AT +48"AFF MAX * ALL LIGHT FIXTURES COMPLETE WITH LAMPS TO BE SUPPLIED BY CACHE.. (UNLESS OTHERWISE NOTED ABOVE) RECEIVED CITY OF TUKWILA JUN 2 0 2013 PERMIT CENTER •ELn Okie ( REVISIONS REVISION N'01L.. EL, EGTR I CAL FLAN SHEET NUMBER E-1 EL•. cc/tr._ — PROVIDE 7 -DAY 11MECLOCK IN NEMA 1 ENCLOSURE IF NONE EXISTING, OR IF EXISTING IS NOT ADEQUATE. E.C. SHALL COORDINATE 11MECLOCK SETTING PATH CACHE' CONSTRUCTION MANAGER AND LANDLORD. A-10 -4-41- TIC — OVR TO UGHT FIXTURES VIA TOGGLE SWITCHES ,.._..z 1 61j0 CI O N N •-• CO 0 N) CC aaaaaaay -- PROVIDE ELECTRICALLY HELD CONTACTOR IN NEMA 1 ENCLOSURE. PROVIDE COIL VOLTAGE OF 120 VOLTS. 2 HOUR MANUAL OVERRIDE SWITCH. VERIFY EXACT LOCATION IN FIELD. LIGHTING CONTROL DIAGRAM Scale: NTS "a" sw a "b" sw b n » sw c » » sw d LAMP VOLTAGE NUMBER DESCRIPTION CKT A-6 SALES FLOOR LIGHTING CKT A-6 SALES FLOOR LIGHTING CKT A-6 SLAES FLOOR UGHTING CKT A-20 COVE LIGHTING sw a sw 'in sw g sw h LAMP VOLTAGE NUMBER DESCRIPTION CKT A-8 CKT A-22 CKT A-4 CKT A-4 TRACK STORE DRESSING DRESSING UGHTING FRONT ROOM ROOM - UGHTING LIGHTING UGHTING MASTER ❑ ALL OFF NOTES: - sw: SWITCH - COORDINATE FINAL SWITCH BANK LOCATION WITH OWNER. - INDICATE EACH SWITCH WITH PERMANENT LABEL PER CODE - VERIFY SWITCH TYPE LIGHTING SWITCHBANK DETAIL Scale: NTS STAGGERED DOUBLE TUBE FLUORESCENT UGHT FIXT , TYPE F FACE OF GYP. BD DEMISING -+ PARTITION GYP. BD. W/ PAINT FINISH BOT. OF DECK ABOVE 0 24 LIGHTING PLAN Scale: 1/4" = 1'-0" MAIN SUSPENSION SYSTEM AS MANUFACTURED BY USG INTERIORS "RIGID X - DONN SUSPENSION SYSTEM" OR EQUAL SECURED TO BOT. BOT OF STRUCTURE ABOVE W/ VERTICAL HANGER WIRE (9 GA) +IO' -O" AFF 5/8" TYPE "X" G i' D, PAINT "UGHTOUER" CMH LAMP HOLDER ON CONT. SUSPENDED TRACK i� 2 1/2" (20 GA) METAL STUD FRAMING / < / 5/8" TYPE "X" GYP. BD, WALLCOVER 511 / 4 SECTION Scale: 1" = 1'-0" KEYED NOTES: 0 LIGHTING TO BE CONTROLLED B SWITCH BANK AND LIGHTING CONTACTOR. SWITCH BANK LOCA11ON SHOWN FOR REFERENCE ONLY, VERIFY EXACT LOCATION WITH OWNER PRIOR T COMMENCING WORK. TIME CLOCK SHALL BE LOCATED ADJACENT TO PAN L A. FURNISH AND INSTALL ALL CONDUIT, WIRE, CONNECTIONS, CONTACTO S, AND TIME CLOCK MODULES NECESSARY TO INSURE A FUNCTIONAL TIME CLOCK SYSTEM IF NONE ARE EXISTING. SEE DETAILS 2 AND 3 ON THIS SHEET FOR MORE INFORMATION. VERIFY 11MECLOCK REQUIREMENTS AND SETTINGS WITH TENANT AND LANDLORD. 0 OCCUPANCY SENSOR "OS" TO CONTROL LIGHTING IN STORAGE AREA. OCCUPANCY SHALL MEET ALL REQUIREMENTS IN SECTION 1513.6.1 OF THE WASHINGTON STATE ENERGY CO E. VERIFY ALL REQUIREMENTS PRIOR TO COMMENCING WORK. OCCUPANCY SENSOR SHALL ALSO BE CONTROLLED VIA TIME CLOCK AND LIGHTING CON -ACTOR. 03 EXISTING LIGHTING IN HALLWAY/RESTROOM TO REMAIN AND BE REUSED. REPAIR/RELAMP AS REQUIRED, EPLACE WHERE NECESSARY. RESTROOM EXHAUST FAN TO REMAIN AND E REUSED. COORDINATE WITH MECHANICAL CONTRACTOR FOR CONDITION OF`` --EXHAUST FAN AND REPAIR/REPLACE AS REQUIRED. CIRCUITRY FOR EXHAUST FAN SHOWN FOR REFERENCE ONLY. VERIFY ALL CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. LIGHTING LEGEND SYMBOL MANUFACTURER MODEL # LAMP VOLTAGE NUMBER DESCRIPTION A IrS5— J UGHTOUER 8242HU 8038CLW/1951 (2) 33W CFL 120V / 66W - SALES FLOOR COMPACT FLUORESCENT 2 LAMP 8" OPEN REFLECTOR DOWNUGHT W/ CLEAR ALZAK CONE & WHITE FLANGE, INTEGRAL ELECTRONIC BALLAST A �� UGHTOUER 8242HU 8038CLW/1951 (2) 33W CFL 120V / 66W - SALES FLOOR EMERGENCY DOWNUGHT. SAME AS TYPE 'A' ABOVE W/ EMERGENCY OPTION & ON 24 HR NIGHT UGHT CIRCUIT. 656 UGHTOUER Ughtolier #22SS3WH-25W MAX 42345 - 13PAR30S/END/F25 3000 DIM 120V / - _ CEILING MID PERIMETER UGHT TRACK W/ LED LAMPS ALL PARTS WHITE FINISH. UGHTOUER 1002P1/1048 -25W 13PAR30S/END/F25 3000 DIM 120V / 13W - RECESSED (1) LAMP ADJUSTABLE SPOT UGHT. D 1211 m, �4q" MERCURY UGH11N(STAG SERIES (2) T5 28W BULBS (2) T5 21W BULBS - 120V / 56W 120V / 42W - - - LENGTHSED DOUBLE E W/ ELECTRONIC BALLAST FLUORESCENT UGHT STRIPS 3', 4', & 6' F(49 51-I/4' 25-7/16" W LUKAS UGHTING CUSTOM (4) 13W 4 -PIN QUAD 120V / - - FITTING ROOM SALON CUSTOM PENDANT UGHT FIXTURE. %% i COLUMBIA FL4L2X4TRELE (2) 4' T-8 3500'K 120V / - - STORAGE ROOM RECESSED 2 X 4 LAY -IN 2 -LAMP FLUORESCENT LIGHT FIXTURE W/ ELECTRONIC BALLAST, & ACRYLIC LENS LUNO LIGHTING Juno MS382WH-25W MAX 42345 - 13PAR30S/END/E25 3000 DIM 120V / 25W - RECESSED FIXTURE FOR STOREFRONT WINDOW. SUITABLE FOR FOR EXTERIOR ENTRANCE DAMP LOCATION. LED LAMPS 9 EX UGHTALARMS SPLEDWRCD - 120V / - - SALES FLOOR / FITTING ROOM WALL OR CEILING MOUNTED EMERGENCY EXIT UGHT SIGN FIXTURE W/ BATTERY BACK-UP. CLEAR ACRYLIC PANEL W/ RED LETTERS & WHITE FACE PLATE. 1421 Ext ��GG PRESCOUTE NAPEXHC3RECCBW - 120V / - - STORAGE ROOM UNIVERSAL MOUNT EMERGENCY UGHT & EXIT SIGN FIXTURE W/ BATTERY BACK-UP. MASTER SHUT-OFF SWITCH FOR ALL UGHTING - RECESSED CEILING MOUNTED AUDIO SPEAKER WITH GRILLE. LIGHTING CONTACTOR "GE �k460XE18" a "POSH 5.25 RETRO CEILING SPEAKER" FOR INSTALLATION IN CEIUNG TILE OR SHEETROCK, PREFINISHED WHILE GRILLE & BEZEL SELF CONTAINED IN STEEL WALL MOUNTED LIGHT SWITCH HOUSING. 1 AMP CURRENT LIIMITER AVAILABLE FROM: "DMX MUSIC" ATTN: MARISA CUPSON PH: (800)831-8001 SPEAKER W/ GRILLE SUPPLIED BY CACHE. INSTALL W/ 16 GA #SPT/162 OCCUPANCY SENSOR SWITCH WIRE. / AND LAMPS WILL BE FURNISHED BY CACHE AND ® THUMBAME ASC EW IO VOLUME ER CONRTROLILLE S (VE FY EXAAS CT LOCATION INN FIELD) -IN BY TENANTS CONTRACTOR, UNLESS OTHERWISE NOTED. THIS SHALL BE RESPONSIBLE FOR RECEIVING, STORING, AND FROM THEFT, BREAKAGE, ETC, AFTER SIGNING FOR RECEIPT. IA ri ALL UGHT FIXTURES INSTALLED CONTRACTOR PROTECTING DATE: 5.26.2015 JOB NO: DRAWN: _ _ CHECKED: _ _ _ 711 N. FIELDER RD. ARUNGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 REVIEWED WITH COMPLIANCE NSC NFP JUN 2 8 2013 Ukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 202013 PERMIT CENTER REVISIONS LIGHTING PLAN SHEET NUMBER E-2 ELECTRICAL SPECIFICATIONS 1. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE LOCAL AUTHORITIES HAVING JURISDICTION AND THE MOST RECENT EDITION OF NA11ONAL ELECTRIC CODE. 2. FURNISH ALL MATERIALS, EQUIPMENT, LABOR, & SERVICES REQUIRED FOR THE INSTALLATION OF ALL ELECTRICAL WORK & AS REQUIRED TO PROVIDE A COMPLETE & OPERABLE ELECTRICAL SYSTEM AS INDICATED ON THE DRAWINGS. 3. CONTRACTOR SHALL GUARANTEE WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE WORKMANSHIP & MATERIALS, USUAL WEAR EXCEPTED, & SHOULD ANY SUCH DEFECTS DEVELOP W/IN A PERIOD OF ONE YEAR ACCEPTANCE OF THE BLDG. BY THE YEAR, THIS CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DEFECTIVE ITEMS & DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE TO THE OWNER. 4. INCIDENTAL ITEMS NOT INDICATED ON THE DRAWINGS, NOR MENTIONED IN THE SPECIFICATIONS, THAT CAN BE LEGITIMATELY & REASONABLE BE INFERRED TO BELONG TO THE WORK DESCRIBED OR BE NECESSARY IN GOOD PRACTICE TO PROVIDE A COMPLETE SYSTEM, SHALL BE FURNISHED & INSTALLED AS THOUGH ITEMIZED HERE IN EVERY DETAIL 5. NOTIFY ARCHITECT IMMEDIATELY OF POSSIBLE CONFLICTS WITH STRUCTURE, MECHANICAL OR OTHER FEATURES. WHERE JOB CONDITIONS REQUIRE REASONABLE CHANGES IN LOCATIONS & ARRANGEMENT OF INDICATED EQUIP., CONDUIT, OUTLETS, OR WIRING, CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT COST TO OWNER. 6. CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. 7. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. 8. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNEUNG AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE COREBORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 9. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. AU. CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER ONES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. 10. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. 11. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY, PRIOR TO ANY INDIVIDUAL CIRCUIT'S INSTALLATION, TO VERIFY WITH ALL OTHER TRADES CONCERNED THAT THE CIRCUIT WITH DEVICES AS DRAWN IS ADEQUATE IN SIZE AND MAKE-UP FOR THE MECHANICAL AND/OR KITCHEN EQUIPMENT TO BE INSTALLED. IF ANY CONFLICT IN VOLTAGE, PHASE OR LOAD IS ENCOUNTERED WHICH WOULD ALTER THE CIRCUIT SIZE, THIS CONTRACTOR SHALL NOTIFY THE ENGINEER OR OWNER IMMEDIATELY. FAILURE TO DO SO SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT CIRCUIT CHANGE DIRECTLY UPON THE CONTRACTOR. 12. GENERAL SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. COMPLETE POWER AND LIGHTING SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION COMPLETE TELEPHONE CONDUIT SYSTEM INCLUDING CONDUIT FROM POINT OF CONNECTION TO UTILITY COMPANY SERVICE AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. PROVISIONS FOR FIRE ALARM SYSTEM AS REQUIRED BY CODE WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE-OUT 13. THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THE AVAILABLE SHORT CIRCUIT CURRENT AT THE SUPPLY TERMINALS FROM THE POWER COMPANY &/OR MALL/SHOPPING CENTER POWER SOURCE. THE SERVICE EQUIPMENT SHALL MEET OR EXCEED THIS RATING PER N.E.C. 14. THE CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE U11UTY COMPANY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR U11UTY COMPANY WIRES. 15. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL STATE AND NEC CODES AND REGULATIONS. 16. PANELBOARDS AND BREAKERS SHALL BE BY SQUARE -D OR EQUAL PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES. PANELBOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFIXED TO THE INSIDE DOOR. 17. ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL BE RATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. 18. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A, 120/277V, WITH. SCREW TERMINALS. MANUFACTURES SHALL BE HUBBELL BRYANT, PASS & SEYMORE, OR LEVITRON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5-20R UNLESS OTHERWISE INDICATED. MANUFACTURES SHALL BE HUBBELL BRYANT, PASS AND SEYMORE, OR LEVITRON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED - THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL -RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOUD-STATE GROUND FAULT SENSING AND SIGNAUNG; WITH 5 MIWAMPERES GROUND - FAULT TRIP LEVEL; IN NEMA 5-15R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS & SEYMORE, OR LEVITRON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2 -POLE, 4 -WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5-15R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG -5362. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WALL PLATES SHALL BE SAME COLOR AS DEVICE AND MANUFACTURED AS A COMPANION TO THE DEVICE. ANY ELECTRICAL OUTLETS WITHIN 4 FEET OF A SINK SHALL BE GFI PROTECTED. PROVIDE EITHER INDIVIDUAL GFI DEVICES OR GFI CIRCUIT BREAKERS, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS OR SCHEDULES. PROVIDE A 120 VOLT RECEPTACLE WITHIN 25 FEET OF ALL HVAC EQUIPMENT. ALL EXTERIOR RECEPTACLES AND DEVICES SHALL BE WEATHERPROOF 19. ALL FEEDERS & BRANCH CIRCUITS SHALL BE THHN/THWN (90' C). DESIGN IS BASED ON COPPER CONDUCTORS & ALL BRANCH CIRCUIT WIRING SHALL BE COPPER. ALL WIRING SHALL BE IN CONDUIT OR MC TYPE. ADDITIONAL CONDUCTOR SPECIFICATIONS: #10 AND SMALLER - SOLID WITH SINGLE BRAID. #8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12 (#14 MAY BE USED FOR CONTROLS) WIRES SHALL BE COLOR CODED IN KEEPING WITH NEC STANDARDS PROVIDE IMC FOR FEEDER CONDUIT WHERE INSTALLED ABOVE GRADE. GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC 250-66 BONDING JUMPER (TYPICAL) EXOTHERMETIC WELD t SCHEDULE 40 PVC APPROVED CONDUIT GROUND CLAMP GROUND BAR SERVICE ENTRANCE CONDUIT BONDING BUSHING INCOMING NEUTRAL/GROUND CONDUCTOR MAIN (208 VOLT) PANELBOARD OR SWITCHBOARD CABINET NEUTRAL BAR MAIN BONDING JUMPER - PROVIDE AT FACTORY OR SIZED PER NEC TABLE 250-66 SCHEDULE 40 PVC SUPPLEMENTAL GROUND #6 AWG MIN. TO GROUND ROD STRUCTURAL STEEL BUILDING MAIN COPPER COLD WATER UNE CONNECT PER NEC 250-52 PANEL CAN OR ENCLOSURE -APPROVED GROUND CLAMP 3/4" x 10' GROUND ROD CONNECT PER NEC 250-52 TYPICAL BONDING & GROUNDING DETAIL Scale: N.T.S. NOTE: BUSHING LOCKNUT LOCKNUT CONDUIT CONNECT UNBROKEN GROUNDING ELECTRODE TO THE MAIN COPPER WATER PIPE WITH SUPPLEMENTAL GROUNDING ELECTRODE AS SHOWN. GROUNDING SYSTEM SHALL COMPLY WITH THE NA11ONAL ELECTRIC CODE ARTICLE 250. .PANEL A (EX STING) 200A 42P 1201208V , 3PH -4W - S{N 200A MCB CK°I. NO. B.RK.R, SIZE SERVICE LOAD 1V1A). PHASE LOAD (VA) SERVICE: BRKR. SIZE CKT. NO. 1 40/3 EXISTING AHU. 3000 A 1-780 EXISTING EF4/FLUOR. LIGHT STQOKIDRESS LIGHTS 20/1 20/1 2 4. 32 3000 13 925 :5 3000 C 765 SALES FLOOR LIGHTS 20/1 6 7 20/1' PHONE ::BOARD 200 A: 720 TRA.CK'LICH:TING 20/1 8 9 2.0/1 SPARE - 13 36.0 TIME CLOCK '20/4 10 11. .2011 EXISTING AHU RECEPTJSERV'ICE LIGHT 280S PARE SPARE 20/1 12 13 2011. RECEPTAC=LES 1080 A SPARE 20/1 14 15 20/1 DEDICATED RECEPTACLES 500 B SPARE 20/1: 16 17 2011 RECEPTACLES 1080 'C. '1200 STOREFRONT SIGN 20/1 18 19 20/1 CASHWRAP 1G RECEPTACLES 500 A. 955 COVE LIGHTING 20/1 20 21: _ 20/1 MUSIC SYSTEM 360 B 36.0 STOREFRONT LIGHTING 2011 22 2011 X,PONDERSECURITY 36 C 300 NIGHT LIGHT ENTER./E IT LIGHTING 2011 25 20/1 MANAGERS DESK RECEPTACLES 360' A SPARE 20/1 .24 26 27 20/1 MANAGERS DESK REC=EPTACLES 360- B SPARE 20/1 28 .29 2:0/1 MANAGER'S DESK RECEPTACLES 'RECEPTACLES 360 C 360 STOREFRONT CEILING RECEPTACLES: 20/1. 30 31 20/'1 720 A SPARE 20/1 32 33 20/1 NETWORK RECEPTACLE 350 SPARE 2011 34- 35 - :S=PACE 0 SPARE 20/1. 36 -37 60E3 EXISTING WATER. HEATER 5000 A SPACE - 38 39 5000 B SPACE - 40 41- 5000 C SPACE - 42 CONNECTED LOAD .A 14315 VA 38245 VA 1 TOTAL LOAD -a: 11225. VA 33745 VA tDEMAN 0 LOAD :CR 12105 VA: 1062- 03.7 TO LANDLORD'S MAIN BUILDING SWITCHGEAR C (EXISTING SERVICE TO REMAIN AND BE REUSED.) EXISTING PANEL A 200A MCB TIMECLOCK - REUSE EXIS11NG IF ADEQUATE, PROVIDE NEW IF NECESSARY. DETAIL 2 ON SHEET E-2 FOR MORE INFORMATION. ONE -LINE DIAGRAM Scale: N.T.S. ONELINE DIAGRAM NOTES: EXISTING 200A, 120/208V-3PH ELECTRICAL SERVICE TO SPACE INCLUDING TO REMAIN AND BE REUSED. CONTRACTOR SHALL VERIFY ALL EQUIPMENT IS WORKING PROPERLY AND REPLACE AS NECESSARY. ALL WORK SHALL BE IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS AND LOCAL CODE. CONTRACTOR BID SHALL INCLUDE ALL WORK NECESSARY FOR A FULLY OPERATIONAL SYSTEM. CONTRACTOR SHALL CONTACT THE ELECTRIC UTILITY CO. TO VERIFY ALL DETAILS OF EXISTING SERVICE AND IS RESPONSIBLE FOR ANY FEES. CONTRACTOR IS RESPONSIBLE FOR A COMPLETE AND OPERATIONAL SYSTEM IN COMPLIANCE WITH NEC AND ALL STATE AND LOCAL CODES. AU. CONDITIONS ARE BASED OFF OF DIRECTION AND INFORMATION PROVIDED FROM ARCHITECT. VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. REVIEWED H CONIPLIANCE NFPA70 - NEC JUN 2 8 2013 amity of TukwilaN = UILDING DIVISION RECEIVED CITY OF TUKWILA JUN 2 0 2013 PERMIT CENTER DATE: 3.26.2015 JOB NO: DRAWN: CHECKED: 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 REVISIONS PANEL SCHEDULE $ NJD/SE RISER SHEET NUMBER E 3 FILE COPY Permit No...,GL" ."i OP 1 Pict r^view approval is subject to errors and omissions. tc of construction documents does not authorize of any adopted code or ordinance. Receipt ni 4iproved Field Cgpygend is acknowledged: By (I Date: fz? -moo _ l City Of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. tr7:: F"'svisions will require a new plan submittal :: J may include additional plan review fees. TEL# TELE TEL# V03 V02 VO1 003 002 D01 SEPARATE PERMIT: REQUIRED FOR: CYIUtechanical O Electrical ?IumbIng graas Piping City of Tukwila S1.it.!Il'�G DIVISION PATCH CABLE CENTRAL PATCHING PARTS LIS : • 12 PORT BOX P/N 41089-12W (6) VOICE JACK P/N 411 06-RL6 (6) DATA/DSL JACK IP/N 5G108 -R05 AS MFG BY "LEVITON". CENTRAL PATCHING BOX "D2" TO BE INSTALLED AT 3x40"AFF OVER MANAGERS DESK IN STORAGE ROOM NOT TO SCALE NOTE: ALL CABLES FROM EACH PC REGISTER WILL BE HOMERUN BACK TO THE CENTRAL PATCHING STATION LOCATED IN STORAGE ROOM. RUN IN 3/4" EMPTY METAL CONDUIT W/ PULL WIRE FOR FUTURE REGISTERS. VERIFY W/ CACHE QUANTITY OF INITIAL REGISTERS FOR OPENING. ALL DATA CABLES WILL BE TERMINATED TO EIA/TTA 5680 SPECIFICATIONS. ALL VOICE CABLES WILL BE TERMINATED TO USOC SPECIFICATIONS PATCHING BOX, JACKS, CONDUIT AND CAT CABLES - SUPPLIED AND INSTALLED BY ON SITE G.C. EQUIPMENT DEVICES, PATCH CABLES, CONNECTOR DEVICES AND HOOK-UPS - SUPPLIED AND INSTALLED BY CACHE. USER/PC PART`S LIST: 4 PORT 80X P/N 41089-4WP (1) VOICE JACK P/N 41106—RL6 (2) DATA JACKS IP/N 56108-R05 AS MFG BY "LEV€TON". PHONE/MODEM RJ12 BLUE DATA RJ45 ORANGE DATA BACK—UP RJ45 ORANGE UNUSED 4 PORT JAC TO BE USED AT EACH REGISTER TO CENTRAL PATCHING STATION IN STORAGE 44—Th ROOM TO EACH PC REGISTER CAT 5E FOR DATA CAT 3 FOR VOICE (MODEM OR PHONE) "D1 D1 » NOT TO SCALE J-12 A-30 A-30 EXIS11NG SIGNAGE CIRCUIT TO3 BE REUSED WHERE POSSIBLE. A-18 INDICATES SAW CUT CHANNEL UNDER 11LE FLOOR FOR 'EXPONDER' LOOPWIRE. A-23 PROVIDE (1) CAT 5 CABLE IN 1/2" CONDUIT ABOVE CEILING FROM FRONT DOOR TO MANAGER'S DESK. A-21 a AFF SURFACE MOUNTED OUTLETS & CONDUITS INSTALLED ON FACE OF PARTITION AT BACK COUNTER UNIT CABINET FOR MUSIC SYSTEM. CABINETRY CONTRACTOR TO PROVIDE 12"Hx18"W CUT-OUT PANEL FOR ACCESS AT LOCATION TBD. A-15 A-19 9` O ® AFF ©V+r�,� AFF ; RECESSED MOUNTED OUTLETS INSTALLED ON INSIDE FACE OF SIDE WRAP CABINET. FIELD VERIFY EXACT LOCATION. CABINETRY CONTRACTOR. TO PROVIDE ACCESS THRU CASH WRAP UNIT FOR TERMINAL INSTALLATION HOOK UP AND INTERCONNECTION. CORE DRILL OR SAW CUT FOR INSTALLATION OF CONDUITS. PATCH FLOOR TO MATCH SURROUNDING FLOOR AREA. COORDINATE WITH MALLS REPRESENTATIVE TO DETERMINE LOCATION OF EXISTING UTILITIES AND TO RECEIVE LANDLORD'S PRIOR APPROVAL f E:E A-31 A-37,39,41 UEXISTING PANEL A CENTRAL PATCHING STATION „02„ - CAT 3 CABLE PATCH CABLE RJ -45 CAT 5E CABLE PC/REGISTERS PC MODEM/PHONE. TO RJ -45 JACK / WALLPLATE TO RJ --12 JACK/WALLPLATE (RUN IN 3/4" MIL CONDUIT) DSL & TELEPHONE LINE NOTES: DAY #1 OF CONSTRUCTION: - ON-SITE G.C. TO INSTALL PLYWOOD PHONE PANEL PER PLAN - ELECTRICAL SUB CONTRACTOR TO: RUN CONDUIT & WIRES FOR POWER, PHONE AND CAD 5 TO CASH/WRAP LOCATION JUNCTION BOX (ALL SURFACE MOUNTED) AT 60" A.F.F. PER PLAN' PHONE AND CAD 5 CABLES TO HAVE 8 -FT. COILED SLACK; AND ATTACH JACK TO END OF PHONE WIRE. BY WEEK #5OF CONSTRUCTION: - ON -SITE G.C. T4 VERIFY THAT DSL & TELEPHONE LINES ARE "UP & RUNNING". PC / REGISTER MODEM PATCH CABLE TO RJ -45 DATA JACK PATCH CABLE TO RJ -12 PHONE / MODEM JACK 1 3 TRANSMIT LOOP WIRE ABOVE DOOR FRAME IN CEILING 24x24 ACCESS PANEL PATCH CABLE TO RJ -45 DATA JACK CONTROL UNIT IN ENTRY SOFFIT PATCH CABLE TO RJ -12 PHONE % MODEM JACK NOTE: ALL CABLES FROM EACH PC REGISTER WILL BE HOMERUN BACK TO THE CENTRAL PATCHING STATION- LOCATED IN STORAGE ROOM. RUN IN 3/4" EMPTY METAL CONDUIT W/ PULL WIRE FOR FUTURE REGISTERS. VERIFY W/ CACHE QUANTITY OF INITIAL REGISTERS FOR OPENING. ALL DATA CABLES WILL BE TERMINATED -TO EIA/TIA 5688 SPECIFICATIONS. 0 TRANSMIT LOOP WIRE "XPONDR" LOOP SYSTEM REFER TO CODED NOTES ON PLAN NOT TO SCALE "XPO POWER PLAN scale: 1/4" =11-0" \IDR" LOOP SYSTEM NOTES & REQUREM,ENTS ACCESS FOR CONTROLLER 24"x24" ACCESS DOOR PROVIDED IN ENTRY CEILING BY CACHE'S ONSITE G.C. REFER TO SPEC. DWG #E-2. DEDICATED POWER OUTLET - - -- TYPE: DEDICATED, BREAKER PROTECTED CIRCUIT. - NUMBER OF OUTLETS: STANDARD 120 VAC SINGLE GANG OUTLET. - AMPS: 15 AMP CIRCUIT BREAKER (LOW VOLTAGE CONTROL / CABLING). - LOCATION: LOCATE OUTLET IN CEILING ON STORE SIDE WITHIN "ARMS REACH" OF THE ACCESS PANEL. - DEDICATED 24HR 12OV DUPLEX RECEPTACLE PROVIDED ABOVE ENTRY SOFFIT BY CACHE'S ONSITE ELECTRICAL CONTRACTOR. -= ALL RELEVANT LOW VOLTAGE PERMITS BY CACHE'S ON SITE ELECTRICAL CONTRACTOR. TRANSMIT LOOP - LOOP WIRE: "XPONDR" PROVIDED 18 AWS STRANDED WIRE FORMS CONTINUOUS LOOP AROUND EXIT -WAY. -- DEPTH: LOOP WIRE IN 1/2" WIDE GROOVE BY 1" DEEP CUT IN CONCRETE COVERED WITH QUICKSET CONCRETE MIX. - LOOP ROUTING: LOOP IS RUN UP VERTICALLY & ACROSS EXIT IN CEILING SPACE TO CONTROL UNIT IN ENTRY SOFFIT. - VARIATION IN TRANSMIT LOOP WIRE RUN REQUIRED FOR STEEL COLUMNS & RED IRON. TRANSMIT LOOP WIRE CANNOT BE RUN IN, BEHIND, OR UNDER STEEL STRUCTURE OR METAL CONDUIT. 1/2"W x 1"D LOOP WIRE SAW -CUT INTO EXISTING CONCRETE SLAB BY CACHE'S ONSITE G.C. G.C. WILL. ENSURE ACCESS FOR LOOP WIRE AT BOTTOM OF VERTICAL 4"SQ ALUMINUM ENTRY COLUMNS. RECEIVE ANTENNAS (3 ANTENNAS REQUIRED) -- DOOR FRAME TYPE: OPTIONAL ROD TYPE - FLOOR TYPE: AUTO TYPE 4 1/2" x 6 1/2" x 1 1/2"D - RECEIVE CABLING: CABLE IS PVC JACKET, 22 AWG 3 -CONDUCTOR, SHIELDED CABLE FIRE: UL 1581, CSA FT4 APPROVAL: CSA AWN II A/B 80C, UL NEC CM 129985 FLOOR WORK: "XPONDR" NEEDS TO BE NOTIFIED AT LEAST TWO WEEKS IN ADVANCE OF THE START DATE OF THE FLOORING OR TILE WORK. FLUORESCENT LIGHTING: SOME TYPES OF ELECTRONIC BALLASTS USED FOR FLUORESCENT LIGHTING CAN CAUSE SIGNIFICANT PERFORMANCE ISSUES FOR "XPONDR" EQUIPMENT. MAGNETIC BALLASTS ARE NOT A PROBLEM, BUT SAMPLES OF ELECTRONIC BALLASTS INTENDED FOR USE IN THE STORE MUST BE SUBMITTED TO "XPONDR" IN ADVANCE FOR TESTING. "XPONDR" CAN RECOMMEND A SUITABLE REPLACEMENT IF NECESSARY ONCE TESTING HAS BEEN COMPLETED. CEILING WORK: IF THE 'STORE 15 NEW CONSTRUCTION OR REMODELING INCLUDES A NEW CEILING, "XPONDR" NEEDS TO HAVE ACCESS TO THE CEILING AT THE SAME TIME AS THE FLOOR WORK. PLEASE CONTACT "XPONDR" IF THE CEILING WILL BE CLOSED NEAR THE DOOR BEFORE THE FLOORING WORK BEGINS. "XPONDR" LOOP SYSTEM KEYED NOTES: O CONTROL UNIT INSTALLED VERTICALLY IN STORE SIDE OF ACCESS SPACE ON METAL STUD FRAMING ABOVE ENTRY CEIUNG WITHIN ARMS REACH OF ACCESS DOOR. INSTALLED BY 'XPONDR". METAL STUD FRAMING BY G.C. COORDINATE WITH "XPONDR". © DEDICATED 24HR 120VAC DUPLEX RECEPTACLE INSTALLED ABOVE ENTRY CEIUNG WITHIN ARMS REACH OF ACCESS DOOR AND WITHIN 4 CABLE FEET OF "XPONDR" CONTROL UNIT BY ONSITE G.C. 0 RECESSED AUTO FLOOR ANTENNAS (3 PIECES) INSTALLED BY "XPONDR". ONSITE G.C. TO PROVIDE SAWCUT 4 -1/2"x6 -1/2"x1-1/2" RELIEF FOR ANTENNAS IN SLAB. ® TRANSMIT LOOPWIRE (18 AWG, 'TEFLON JACKET) CONTINUOUS LOOP AND ANTENNA CABLE S IN SLAB TO RUN UP INSIDE ENTRY INTO OVERHEAD, INSTAIJ.ED BY XPONDR. ONSITE G.C. TO PROVIDE 1/2"Wx1"D SAWCUT FOR CONTINUOUS LOOP IN SLAB. VARIATION IN TRANSMIT LOOP WIRE RUN REQUIRED FOR STEEL COLUMNS, RED IRON. 0 DIGITAL ALARM DISPLAY WALL MOUNTED ABOVE ENTRY DOORS, INSTALLED BY "XPONDR". © ALL CABLES AND TRANSMIT LOOP WIRE TERMINATE AT CONTROL UNIT BY "XPONDR". ONSITE G.C. TO PROVIDE OPEN ACCESS AT 2 ENTRY COLUMNS FROM SLAB TO ABOVE ENTRY CEIUNG FOR "XPONDR" TO RUN LOOP WIRES AND OPTIONAL SIDE WALL ANTENNAE. 24" x 24" ACCESS DOOR. REFER TO SPECS ON DWG hE-2. 411 nri2" FAR TEL PAR El®o® 24 HR 24 RR SCHEMATIC ELEVATION STOCK ROOM MANAGER'S DESK KEYED NOTES: PHONE BOARD O EXISTING AIR -HANDLING UNIT (AHU) TO REMAIN AND BE REUSED. E.C. SHALL VERIFY ALL WIRING, DISCONNECT AND CIRCUITRY IS IN GOOD WORKING ORDER AND REPAIR/REPLACE AS REQUIRED. VERIFY THERE IS AN EXISTING SERVICE LIGHT/SERVICE RECEPTACLE AND THAT IT IS IN GOOD WORKING ORDER. REPAIR/REPLACE AS NEEDED OR PROVIDE ONE IF NONE IS EXISTING. LOCA11ON AND CIRCUITRY SHOWN FOR REFERENCE ONLY. VERIFY ALL CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. O2 EXISTING WATER HEATER TO REMAIN AND BE REUSED. E.C. SHALL VERIFY ALL WIRING, DISCONNECT AND CIRCUITRY IS IN GOOD WORKING ORDER AND REPAIR/REPLACE AS REQUIRED. LOCA11ON AND CIRCUITRY SHOWN FOR REFERENCE ONLY. VERIFY ALL CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. O3 E.C. SHALL EXTEND EXISTING BRANCH CIRCUIT FEEDERS AND CONDUIT FOR EXISTING STOREFRONT SIGN TO SERVICE PANEL "A" AND RECONNECT. VERIFY COMPLETE LENGTH AND ROUTING IN FIELD. STOREFRONT SIGN TO BE CONTROLLED VIA 7 -DAY TIME CLOCK. SEE DETAIL 2 ON SHEET E-2 FOR MORE INFORMA11ON. 0 EXISTING ELECTRICAL SERVICE PANEL "A" TO REMAIN AND BE REUSED. E.C. TO VERIFY SERVICE EQUIPMENT IS ADEQUATE AND IN GOOD WORKING ORDER. REPAIR/REPLACE AS NECESSARY. SEE ONE -LINE DIAGRAM ON SHEET E-3 FOR FURTHER INFORMA11ON. TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR FOR DESIGN AND PROGRAMING AND FINAL CONNECTIONS TO LANDLORD'S ;FIRE ALARM SYSTEM AT TENANTS EXPENSE. TENANT SHALL USE ONLY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. VERIFY ALL REQUIRED WORK PRIOR TO PLACING BID. O STORE FRONT CEILING MOUNTED RECEPTACLES TO BE CONTROLLED VIA 11MECLOCK. SEE DETAIL 2 ON SHEET E-2 FOR MORE INFORMATION. POWER & SIGNAL LEGEND_ SYMBOL DESCRIPTION RECESSED DUPLEX ELECTRICAL CONVENIENCE OUTLET MOUNTED HORIZONTALLY AT 6 1 /2"AFF. (UNLESS OTHERWISE NOTED). RECESSED DUPLEXELECTRICAL CONVENIENCE OUTLET MOUNTED VERTICALLY AT + 15" AFF (UNLESS OTHERWISE NOTED) RECESSED QUADRUPLEX ELECTRICAL OUTLET MOUNTED q VERTICALLY, AT + 18" AFF (UNLESS OTHERWISE NOTED) ELECTRICAL JUNCTION BOX MOUNTED AT HEIGHT AS NOTED ON PLAN RECESSED 3 GANG WALL BOX MOUNTED AT + 9" AFF P.O.S. TERMINAL DEDICATED CIRCUIT FOR ELECTRIC -DATA -TELEPHONE RECESSED PC REGISTER JACK. SEE DETAIL THIS DWG. CENTRAL PATCHING STATION. SEE DETAIL THIS DWG. RECESSED WALL TELEPHONE JACKS MOUNTED VERTICALLY AT HEIGHTS AS NOTED ON PLAN. TO BE SUPPLIED & INSTALLED BY ON SITE G.C. 5 PHONE JACKS REQ'D: SALES COUNTER ( 2 PHONE 2 COMPUTER) STORAGE ROOM MGR. DESK (1 PHONE) STEREO SPEAKER INPUT JACK PANEL MOUNTED AT + 60" AFF 144 IO RECESSED IN WALL VOLUME CONTROL BOx TO CONTROL FITTING ROOM AUDIO SPEAKER ONLY. "RADIO SHACK" CAT.40-993 EXISTING RECESSED CEILING MOUNTED EXAUST FAN NOT TO SCALE NOTES: TOILET ROOM CEILING SURFACE MTD 1 X 4 2 --LAMP FLUORESCENT LIGHT FIXTURE W/ ELECTRONIC BALLAST, ACRYLIC LENS, & T-8 3000'K LAMPS. "MERCURY LIGHTING" M 106 -232 -OCT -A- ELB- 120V (OR APPROVED EQUAL) PUSH BUTTON BUTTON AND BUZZER "EDWARDS" #115-165 BUZZER ALL DUPLEX OUTLETS, WALL SWITCHES, DIMMER CONTROLS, PHONE JACKS, AND ALL EXPOSED ELECTRICAL DEVICES TO BE INSTALLED W/ IVORY COLOR BAKELITE COVER PLATES ALL WALL MTD SWITCHES & CONTROLS TO BE INSTALLED AT +48"AFF MAX ALL LIGHT FIXTURES COMPLETE WITH LAMPS TO BE SUPPLIED BY CACHE.. (UNLESS OTHERWISE NOTED ABOVE) DATE: 5.26.2013 JOB NO: DRAWN: CHECKED: _ _ _ 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 W 2 EL a J Q3 cc U O REVISIONS REVIEWED FOR COMPLIANCE LITH NPPA?0 APR 2'-2013 City of Tukwila D VIISION BUILDING RECEIVED CITY OF TUKWILA APR 1 8 2013 PERMIT CENTER EL.!C TRIGAL. � FL.A SHEET NUMBER O'1/4e I E 1 — PROVIDE 7 -DAY TIMECLOCK IN NEMA 1 ENCLOSURE IF NONE EXISTING, OR IF EXISTING IS NOT ADEQUATE. E.C. SHALL COORDINATE TIMECLOCK SETTING WITH CACHE' CONSTRUCTION MANAGER AND LANDLORD. A-10 T/C — OV—R1— irTO LIGHT FIXTURES VIA TOGGLE SWITCHES • NI' CD OD O N CO O W aaaaQgaa PROVIDE ELECTRICALLY HELD CONTACTOR IN NEMA 1 ENCLOSURE. PROVIDE COIL VOLTAGE OF 120 VOLTS. 2 HOUR MANUAL OVERRIDE SWITCH. VERIFY EXACT LOCATION IN FIELD. LIGHTING CONTROL DIAGRAM Scale: NTS sw "a" sw "b" sw "c" sw "d" ❑ ❑ ❑ ❑ CKT A-6 CKT A-6 CKT A-6 CKT A-20 SALES FLOOR SALES FLOOR SLAES FLOOR COVE LIGHTING LIGHTING UGHTING LIGHTING sw "e" ❑ sw "f" ❑ sw "g" ❑ sw "h" ❑ CKT A-8 CKT A-22 CKT A-4 CKT A-4 TRACK STORE DRESSING DRESSING LIGHTING FRONT ROOM ROOM LIGHTING LIGHTING LIGHTING MASTER ALL OFF NOTES: - sw: SWITCH - COORDINATE FINAL SWITCH BANK LOCATION WITH OWNER. - INDICATE EACH SWITCH WITH PERMANENT LABEL PER CODE - VERIFY SWITCH TYPE LIGHTING SWITCHBANK DETAIL Scale: NTS STAGGERED DOUBLE TUBE FLUORESCENT LIGHT FIXT., TYPE F EX A-24 AlC r A LO A-24 AO*€ NL A€O E A Ago A A sw "a" 1 A-6 c-� A-6 sw c D E0D D sw e" A-8 sw "b" O A-6 A-24 A€O*€ NL FACE OF GYP. BD DEMISING —+ PARTITION GYP. BD. W/ PAINT FINISH O BOT. OF DECK ABOVE 0 LIGHTING PLAN sca€e: 1/4" = 1'-0" MAIN SUSPENSION SYSTEM AS MANUFACTURED BY USG INTERIORS "RIGID X - DONN SUSPENSION SYSTEM" OR EQUAL SECURED TO BOT. BOT OF STRUCTURE ABOVE W/ VERTICAL HANGER WIRE (9 GA) +10'-0" All 5/8" TYPE "X" G i' : D, PAINT "UGHTOUER" CMH LAMP HOLDER ON CONT. SUSPENDED TRACK 2 1/2» (20 GAMETAL STUD FRAMING < / 5/8" TYPE "X" GYP. BD, WALLCOVER 24 511 SECTION scale: 1" = 1'-0" KEYED NOTES: A-4 H 0 LIGHTING TO BE CONTROLLED BY SWITCH BANK AND LIGHTING CONTACTOR. SWITCH BANK LOCATION SHOWN FOR REFERENCE ONLY, VERIFY EXACT LOCATION WITH OWNER PRIOR TO COMMENCING WORK. TIME CLOCK SHALL BE LOCATED ADJACENT TO PANEL A. FURNISH AND INSTALL ALL CONDUIT, WIRE, CONNECTIONS, CONTACTORS, AND TIME CLOCK MODULES NECESSARY TO INSURE A FUNCTIONAL TIME CLOCK SYSTEM IF NONE ARE EXISTING. SEE DETAILS 2 AND 3 ON THIS SHEET FOR MORE INFORMATION. VERIFY TIMECLOCK REQUIREMENTS AND SETTINGS WITH TENANT AND LANDLORD. O2 OCCUPANCY SENSOR "OS" TO CONTROL UGHTING IN STORAGE AREA. OCCUPANCY SHALL MEET ALL REQUIREMENTS IN SECTION 1513.6.1 OF THE WASHINGTON STATE ENERGY CODE. VERIFY ALL REQUIREMENTS PRIOR TO COMMENCING WORK. OCCUPANCY SENSOR SHALL ALSO BE CONTROLLED VIA TIME CLOCK AND UGHTING CONTACTOR. O3 EXISTING LIGHTING IN HALLWAY/RESTROOM TO REMAIN AND BE REUSED. REPAIR/RELAMP AS REQUIRED, REPLACE WHERE NECESSARY. RESTROOM EXHAUST FAN TO REMAIN AND BE REUSED. COORDINATE WITH MECHANICAL CONTRACTOR FOR CONDITION OF EXHAUST FAN AND REPAIR/REPLACE AS REQUIRED. CIRCUITRY FOR EXHAUST FAN SHOWN FOR REFERENCE ONLY. VERIFY ALL CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. SYMBOL MANUFACTURER LIGHTING LEGEND MODEL I LAMP VOLTAGE NUMBER A 5 rO � ] UGHTOUER 8242HU 8038CLW/1951 (2) 33W CFL 120V / 66W DESCRIPTION SALES FLOOR COMPACT FLUORESCENT 2 LAMP 8" OPEN REFLECTOR DOWNUGHT W/ CLEAR ALZAK CONE & WHITE FLANGE, INTEGRAL ELECTRONIC BALLAST ALQ 4� UGHTOUER 8242HU 8038CLW/1951 (2) 33W CFL 120V / 66W Est r -I L'J UGHTOUER Lightolier ,#22SS3WH-25W MAX UGHTOUER 1002P1/1048 -25W MAX 42345 — 42345 OS/END/F25 3000 DIM 42345 - 42345 0S/END/F25 3000 DIM 120V / - SALES FLOOR EMERGENCY DOWNUGHT. SAME AS TYPE 'A' ABOVE W/ EMERGENCY OPTION & ON 24 HR NIGHT LIGHT CIRCUIT. CEIUNG MTD PERIMETER UGHT TRACK W/ LED LAMPS ALL PARTS WHITE FINISH. 120V / 13W RECESSED (1) LAMP ADJUSTABLE SPOT LIGHT. I(4')4Q" F 5'1-I/4' Mr25-1/I6* MERCURY UGHTI NOTAG SERIES (2) T5 28W BULBS (2) T5 21W BULBS 120V / 56W 120V / 42W STAGGERED DOUBLE TUBE FLUORESCENT LIGHT STRIPS 3', 4', & 6' LENGTHS W/ ELECTRONIC BALLAST •foriss. 11 +1 LUKAS LIGHTING COLUMBIA CUSTOM FL4L2X4TRELE (4) 13W 4 -PIN QUAD (2) 4' T-8 3500'K 120V / - 120V / - FITTING ROOM SALON CUSTOM PENDANT LIGHT FIXTURE. STORAGE ROOM RECESSED 2 X 4 LAY -IN 2 -LAMP FLUORESCENT LIGHT FIXTURE W/ ELECTRONIC BALLAST, & ACRYLIC LENS JUNO LIGHTING Juno MS382WH-25W MAX 42345 - 42345 OS/END/F25 3000 DIM 120V / 25W RECESSED FIXTURE FOR STOREFRONT WINDOW. SUITABLE FOR FOR EXTERIOR ENTRANCE DAMP LOCATION. LED LAMPS Y EX UGHTALARMS SPLEDWRCD 120V / - SALES FLOOR / FITTING ROOM WALL OR CEIUNG MOUNTED EMERGENCY EXIT LIGHT SIGN FIXTURE W/ BATTERY BACK-UP. CLEAR ACRYLIC PANEL W/ RED LETTERS & WHITE FACE PLATE. EX2 PRESCOUTE NAPEXHC3RECCBW 120V / - STORAGE ROOM UNIVERSAL MOUNT EMERGENCY LIGHT & EXIT SIGN FIXTURE W/ BATTERY BACK-UP. Is- MASTER SHUT-OFF SWITCH FOR ALL LIGHTING - UGHTING CONTACTOR "GE #460XEIB" WALL MOUNTED LIGHT SWITCH El 1 AMP CURRENT LIIMITER OCCUPANCY SENSOR SWITCH ALL LIGHT FIXTURES AND LAMPS WILL BE FURNISHED BY CACHE AND INSTALLED BY TENANTS CONTRACTOR, UNLESS OTHERWISE NOTED. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORING, AND PROTECTING FROM THEFT, BREAKAGE, ETC, AFTER SIGNING FOR RECEIPT. RECESSED CEILING MOUNTED AUDIO SPEAKER WITH GRILLE. "POSH 5.25 RETRO CEIUNG SPEAKER" FOR INSTALLATION IN CEIUNG TILE OR SHEETROCK, PREFINISHED WHITE GRILLE & BEZEL SELF CONTAINED IN STEEL HOUSING. AVAILABLE FROM: "DMX MUSIC" ATTN: MARISA CUPSON PH: (800)831-8001 SPEAKER W/ GRILLE SUPPLIED BY CACHE. INSTALL W/ 16 GA #SPT/162 WIRE. ® SAME AUDIO SPEAKER & GRILLE SPEC AS ABOVE - EXCEPT W_ / BUILT-IN THUMB SCREW VOLUME CONTROL. (VERIFY EXACT LOCATION IN FIELD). DATE: 3.26.2018 JOB NO: DRAWN: CHECKED: _ _ _ 711 N. FIELDER RD. ARUNGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 2\Q2) Q a. Eca-J a3 CCM 5U co REVIEWED FUh COMPLIANCE WITH NFPA70 - NEC APR 2 4 2013 City of.Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 18 2013 PERMIT CENTER REVISIONS LIGHTING SHEET NUMBER E-2 ELECTRICAL SPECIFICATIONS 1. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE LOCAL AUTHORITIES HAVING JURISDICTION AND THE MOST RECENT EDITION OF NATIONAL ELECTRIC CODE. 2. FURNISH ALL MATERIALS, EQUIPMENT, LABOR, & SERVICES REQUIRED FOR THE INSTALLATION OF ALL ELECTRICAL WORK & AS REQUIRED TO PROVIDE A COMPLETE & OPERABLE ELECTRICAL SYSTEM AS INDICATED ON THE DRAWINGS. 3. CONTRACTOR SHALL GUARANTEE WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE WORKMANSHIP & MATERIALS, USUAL WEAR EXCEPTED, & SHOULD ANY SUCH DEFECTS DEVELOP W/IN A PERIOD OF ONE YEAR ACCEPTANCE OF THE BLDG. BY THE YEAR, THIS CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DEFECTIVE ITEMS & DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE TO THE OWNER. 4. INCIDENTAL ITEMS NOT INDICATED ON THE DRAWINGS, NOR MENTIONED IN THE SPECIFICATIONS, THAT CAN BE LEGITIMATELY & REASONABLE BE INFERRED TO BELONG TO THE WORK DESCRIBED OR BE NECESSARY IN GOOD PRACTICE TO PROVIDE A COMPLETE SYSTEM, SHALL BE FURNISHED & INSTALLED AS THOUGH ITEMIZED HERE IN EVERY DETAIL 5. NOTIFY ARCHITECT IMMEDIATELY OF POSSIBLE CONFLICTS WITH STRUCTURE, MECHANICAL OR OTHER FEATURES. WHERE JOB CONDITIONS REQUIRE REASONABLE CHANGES IN LOCATIONS & ARRANGEMENT OF INDICATED EQUIP., CONDUIT, OUTLETS, OR WIRING, CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT COST TO OWNER. 6. CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. 7. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. 8. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE COREBORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 9. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER UNES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH ONES. 10. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. 11. IT SHALL BE THIS CONTRACTOR'S RESPONSIBIUTY, PRIOR TO ANY INDIVIDUAL CIRCUIT'S INSTALLATION, TO VERIFY WITH ALL OTHER TRADES CONCERNED THAT THE CIRCUIT WITH DEVICES AS DRAWN IS ADEQUATE IN SIZE AND MAKE-UP FOR THE MECHANICAL AND/OR KITCHEN EQUIPMENT TO BE INSTALLED. IF ANY CONFLICT IN VOLTAGE, PHASE OR LOAD IS ENCOUNTERED WHICH WOULD ALTER THE CIRCUIT SIZE, THIS CONTRACTOR SHALL NOTIFY THE ENGINEER OR OWNER IMMEDIATELY. FAILURE TO DO SO SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT CIRCUIT CHANGE DIRECTLY UPON THE CONTRACTOR. 12. GENERAL SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. COMPLETE POWER AND UGHI1NG SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION COMPLETE TELEPHONE CONDUIT SYSTEM INCLUDING CONDUIT FROM POINT OF CONNECTION TO UTILITY COMPANY SERVICE AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. PROVISIONS FOR FIRE ALARM SYSTEM AS REQUIRED BY CODE WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE-OUT 13. THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THE AVAILABLE SHORT CIRCUIT CURRENT AT THE SUPPLY TERMINALS FROM THE POWER COMPANY &/OR MALL/SHOPPING CENTER POWER SOURCE. THE SERVICE EQUIPMENT SHALL MEET OR EXCEED THIS RATING PER N.E.C. 14. THE CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY COMPANY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR U11UTY COMPANY WIRES. 15. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY MTH ALL LOCAL STATE AND NEC CODES AND REGULATIONS. 16. PANELBOARDS AND BREAKERS SHALL BE BY SQUARE -D OR EQUAL PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES. PANELBOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFIXED TO THE INSIDE DOOR. 17. ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL BE RATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. 18. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A, 120/277V, WITH SCREW TERMINALS. MANUFACTURES SHALL BE HUBBELL, BRYANT, PASS & SEYMORE, OR LEVITRON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5-20R UNLESS OTHERWISE INDICATED. MANUFACTURES SHALL BE HUBBELL BRYANT, PASS AND SEYMORE, OR LEVITRON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED - THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL -RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOLID-STATE GROUND FAULT SENSING AND SIGNAUNG; WITH 5 MIWAMPERES GROUND FAULT TRIP LEVEL; IN NEMA 5-15R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL BRYANT, PASS & SEYMORE, OR LEVITRON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2 -POLE, 4 -WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5-15R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG -5362. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WALL PLATES SHALL BE SAME COLOR AS DEVICE AND MANUFACTURED AS A COMPANION TO THE DEVICE. ANY ELECTRICAL OUTLETS WITHIN 4 FEET OF A SINK SHALL BE GFI PROTECTED. PROVIDE EITHER INDIVIDUAL GFI DEVICES OR GFI CIRCUIT BREAKERS, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS OR SCHEDULES. PROVIDE A 120 VOLT RECEPTACLE WITHIN 25 FEET OF ALL HVAC EQUIPMENT. ALL EXTERIOR RECEPTACLES AND DEVICES SHALL BE WEATHERPROOF 19. ALL FEEDERS & BRANCH CIRCUITS SHALL BE THHN/THWN (90' C). DESIGN IS BASED ON COPPER CONDUCTORS & ALL BRANCH CIRCUIT WIRING SHALL BE COPPER. ALL WIRING SHALL BE IN CONDUIT OR MC TYPE. ADDITIONAL CONDUCTOR SPECIFICATIONS: #10 AND SMALLER - SOLID WITH SINGLE BRAID. #8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12 (#14 MAY BE USED FOR CONTROLS) WIRES SHALL BE COLOR CODED IN KEEPING WITH NEC STANDARDS PROVIDE IMC FOR FEEDER CONDUIT WHERE INSTALLED ABOVE GRADE. GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC 250-66 BONDING JUMPER (TYPICAL) EXOTHERMETIC WELD 6 \- SCHEDULE 40 PVC APPROVED -c CONDUIT GROUND CLAMP SERVICE ENTRANCE CONDUIT - BONDING BUSHING -INCOMING NEUTRAL/GROUND CONDUCTOR GROUND BAR MAIN (208 VOLT) PANELBOARD OR SWITCHBOARD CABINET NEUTRAL BAR MAIN BONDING JUMPER - PROVIDE AT FACTORY OR SIZED PER NEC TABLE 250-66 SCHEDULE 40 PVC SUPPLEMENTAL GROUND #6 AWG MIN. TO GROUND ROD -APPROVED GROUND CLAMP 3/4" x 10' GROUND ROD CONNECT PER NEC 250-52 STRUCTURAL STEEL BUILDING MAIN COPPER COLD WATER UNE CONNECT PER NEC 250-52 PANEL CAN OR ENCLOSURE TYPICAL BONDING & GROUNDING DETAIL Scale: N.T.S. BUSHING LOCKNUT LOCKNUT CONDUIT NOTE: CONNECT UNBROKEN GROUNDING ELECTRODE TO THE MAIN COPPER WATER PIPE WITH SUPPLEMENTAL GROUNDING ELECTRODE AS SHOWN. GROUNDING SYSTEM SHALL COMPLY MTH THE NATIONAL ELECTRIC CODE ARTICLE 250. PANEL A EXISTING) 200A 42P 120/208V - 3PH 4W - SIN 200A MCB CKT.. No. B RKR.. -SIZE SERVICE LOAD (VA} PHASE LOAD (VA) SERVICE BRKR. SIZE CKT. NO. 1 3. 5 40/3 EXISTING AHL.• 3000 3000 3000 -925 768 EXISTING :EF 1:IFLUOR. LIGHT SrTCCKIDRESS LIGHTS SALES FLOOR LIGHTS 2011: 20/1 20/1 2 4: 6 20/1 PHcN E:;BOARD 200 A: 720 TRACK L.IGHTJNG 20/1 8 9 20/1 SPARE B 380 TIME :CLOCK 20/1; 10 11. 20/1 EXISTING. RECEPTJSERVICE LIGHT :280 G S.PARE 2011 12 13. 20/1:: ITEC-E:PTAC ................... 1 080 SPARE 20/1 14 15 20/1 :DED CATE:D :REC'EPTACLES .:600 SPARE 20/1: 1.6 17 20/1 RECEPTAC:LE; 1080 1200: STOREFRONT SIGN 20/1 18 19 20/1 CASHV R P IG RECEPTACLES 500 . A. 955 COVE LIGHTING 20/1 20 21. 20/1 MU'5. SYSTENMI • :360 B. 360 STOREFRONT LIGHTING 20/1 22 23 10/1 3.0:PCNDER &&EC"U ftITY -MANAGER'S DESK RECEPTACLES Q' 300 NIGHT LIGi TIE1 E JE ff LIGHTING: HTING: 20/1; 24: 25 20/1 360 A SPARE 20/1 26. 27 20/1 MA.NAG.ER`S CESK RECEPTACLES 360 SPARE 20/1 28 :29 .20/1 MANAGER'S DESK' IRECE 3TACLEES '360 C 3:60 STOREFRONT CEILING:REC'EPTACLE.S 20/1; :30 31. 20/1 RECEPTACLE "720 A. SPARE 20/1 32 33 20/1:. :ETi V RK: RECEPTACLE 360 SPARE. 20/1 344 SPA.ICE SPARE 20/1 36 37 39 41 60/3 EXISTING WATER. HEATER 2500 :SPACE 5000 B SPACE 38 40 2500 C. SPAC E 42 CONNECTED LOAD A: C: 11815 VA 11225' 'A 10205 'VA 33245 VA ':TOTAL LOAD 30245 VA :DEMAND LOAD 92.3 84.0 TO LANDLORD'S MAIN BUILDING SWITCHGEAR C (EXISTING SERVICE TO REMAIN AND BE REUSED.) EXISTING PANEL A 200A MCB T/C 11MECLOCK - REUSE EXISTING IF ADEQUATE, PROVIDE NEW IF NECESSARY. DETAIL 2 ON SHEET E-2 FOR MORE INFORMATION. ONE -LINE DIAGRAM Scale: N.T.S. ONELINE DIAGRAM NOTES: EXISTING 200A, 120/208V-3PH ELECTRICAL SERVICE TO SPACE INCLUDING TO REMAIN AND BE REUSED. CONTRACTOR SHALL VERIFY ALL EQUIPMENT IS WORKING PROPERLY AND REPLACE AS NECESSARY. ALL WORK SHALL BE IN ACCORDANCE WITH U11UTY COMPANY REQUIREMENTS AND LOCAL CODE. CONTRACTOR BID SHALL INCLUDE ALL WORK NECESSARY FOR A FULLY OPERATIONAL SYSTEM. CONTRACTOR SHALL CONTACT THE ELECTRIC U11UTY CO. TO VERIFY ALL DETAILS OF EXISTING SERVICE AND IS RESPONSIBLE FOR ANY FEES. CONTRACTOR IS RESPONSIBLE FOR A COMPLETE AND OPERATIONAL SYSTEM IN COMPUANCE WITH NEC AND ALL STATE AND LOCAL CODES. ALL CONDITIONS ARE BASED OFF OF DIRECTION AND INFORMATION PROVIDED FROM ARCHITECT. VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO COMMENCING WORK. DATE: 5.26.2015 JOB NO: DRAWN: CHECKED: REVIEWED ,MR COMPLIANCE �E�TW NFPA APR 242013 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 Yo �& BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 8 2013 PERMIT CENTER W 0 co LL E cn J a ac w p 0 co REVISIONS PANEL SGH!PUJ_! 4 SI S!R SHEET NUMBER E-3