Loading...
HomeMy WebLinkAboutPermit EL13-0437 - NORMED - TENANT IMPROVEMENT This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL13-0437 Normed st 4320 S 131 Pl DIGITAL RECORDS (DR) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Code Exemption Brief Explanatory Description Statute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers 5 U.S.C. sec. individuals’ privacy pursuant to 5 U.S.C. sec. DR1 Generally – 5 U.S.C. sec. 552(a); RCW 552(a), and are also exempt from disclosure under section 42.56.070(1) of the Washington 552(a); RCW 42.56.070(1) State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW 19 DR2 Financial Information – account numbers, which are exempt from 42.56.230(5) disclosure pursuant to RCW 42.56.230(5) RCW 42.56.230(4 5) , except when disclosure is expressly required by or governed by other law. NORMED 4320 S 131 PL EL1 3-0437 City o#fukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200095 Address: 4320 S 131 PL TUKW Project Name: NORMED ELECTRICAL PERMIT Permit Number: EL13-0437 Issue Date: 06/06/2013 Permit Expires On: 12/03/2013 Owner: Name: NORMED SHAW PTN Address: PO BOX 3644 , SEATTLE WA 98124 Contact Person: Name: COREY MCKINNON Address: 7056 S 220 ST , KENT WA, 98032 Contractor: Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST , KENT WA 98032 Contractor License No: SEATAEI077RW Phone: 253 872-2354 Phone: Expiration Date: 12/17/2013 ?DESCRIPTION OF WORK: ELECTRICAL TENANT IMPROVEMENT TO INCLUDE WORK ON FEEDERS, LIGHTING, POWER, LOW VOLTAGE, AND ELECTRICAL MECHANICAL CONNECTIONS. Value of Electrical: NRES: $70,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: UNKNOWN National Electrical Code Edition: Electrical service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: $1,506.75 2008 Date: L2-1-(3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this construction or the Signature: t does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ance of w rk. I am ._horized to sign and obtain this electrical permit. Date: 6.—i6--/-3 Print Name: S{eUe k ;lid I e7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL13-0437 Printed: 06-06-2013 PERMIT CONDITIONS Permit No. EL 13-0437 **ELECTRICAL** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL13-0437 Printed: 06-06-2013 CITY OF TUKW 1 Community Development Deparent Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA. gov ELECTRICAL Applications and plans must be Applications will not - 11111 Electrical Permit No. s Project No. 37 Date Application Accepted: Date Application Expires: oo-6l.ii (For office use only) 01 h PERMIT APPLICATION complete in order to be accepted for plan review. be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 4320 SOUTH 131ST PLACE Suite Number: Tenant Name: NORMED PROPERTY OWNER Name: COREY MCKINNON Address: 7056 S. 220TH STREET Name: 1 jowoo c7 Email: corey.m@seatacelectric.com Address: 90 o v l 7��LH ' �tatate: City: � State: { 1 A. Zip: ql i Lit CONTACT PERSON — person receiving all project communication Name: COREY MCKINNON Address: 7056 S. 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 872-2354 Fax: (253) 872-4112 Email: corey.m@seatacelectric.com 1'94 1943$ —DOC Floor: 1ST/MEZ New Tenant: ❑ Yes ®..No ELECTRICAL CONTRACTOR INFORMATION Company Name: SEA -TAC ELECTRIC, INC. Address: 7056 S. 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 867-2354 Fax: (253) 872-4112 Contr Reg No.: SEATAEI077RW Exp Date: 12/01/2013 Tukwila Business License No.: 01-212 Valuation of Project (contractor's bid price): $ 70,000 Scope of Work (please provide detailed information): ELECTRICAL TENANT IMPROVEMENT TO INCLUDE WORK ON FEEDERS, LIGHTING, POWER, LOW VOLTAGE & ELECTRICAL MECHANICAL CONNECTIONS. INCLUDE THE RELOCATION, REMOVAL AND INSTALLATION OF MISC ELECTRICAL SYSTEMS PERTAINING TO THE AFOREMENTIONED SCOPE OF WORK Will service be altered? ❑ Yes ❑✓ No Adding more than 50 amps? ❑✓ Yes ❑ No Type of Use: COMMERCIAL Type of work: ❑ New 0 Addition ❑ Low Voltage 0 Generator Property Served by: ® Puget Sound Energy 0 Seattle City Light ❑ Service Change ❑ Fire Alarm H:\Application\Forms-Apphcmtons On Lme\201 I Applications\Electrical Permit Application Revised 8-9-11 .docx Revised: August 2011 bh ❑ Remodel O Telecommunication • Tenant Improvement O Temporary Service Page 1 of 2 • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT :APPLICATIONG 9NOyjIE; Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 05/08/2013 Print Name: COREY MCKINNON Day Telephone: (253) 867-2354 Mailing Address: 7056 S. 220TH STREET KENT WA 98032 City H:\Applications\Forms-Applications On Line \2011 Applications \Electrical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh State Zip Page 2 of 2 r City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200095 Address: 4320 S 131 PL TUKW Suite No: Applicant: NORMED RECEIPT Permit Number: EL13-0437 Status: PENDING Applied Date: 05/08/2013 Issue Date: Receipt No.: R13-01553 Payment Amount: $1,506.75 Initials: TEM Payment Date: 05/08/2013 01:18 PM User ID: 1165 Balance: $0.00 Payee: COREY MCKINNON, SEA TAC ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 008691 ACCOUNT ITEM LIST: Description 1,506.75 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $1,506.75 1,205.40 301.35 Printprl• ns_nR-2n13 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: t\b nl Type of Inspection: 2-1°0 x( Address: 2 2.0 S• !0 PC, Date Called: ---, Special Instructions: n� \ CM I `* , ��` Date Wanted: g 0f? p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval.- OMMENTS: it Inspector: 46\ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: alai() () INSPECTION RECORD Retain a copy with permit 5 a ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: i aQ1l Type of Inspection: 0 DO Address: i � '. /3 ? fL Date Called: _ Special Instructions: Date Wanted: 4117 . aRequester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Abi 0-494 CoAlwrr 44) 71)3 - 1.1.4 6s/6R, Inspector: Date: a a 13 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 INSPECTION= RECORD Retain a copy with., permit INSPECTION NO. • fu3-637 PERMIT NO. CITY OF TUKWILA BUILDING ,DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: dokil Type of Inspection: Address: giao /31 pL. Date Called: Special Instructions: Date Wanted: it m. Requester: Phone No: AOApproved per applicable codes. IBJ Corrections required prior to approval. COMMENTS: -7-WAISk.5,16-c 4q.c.h\t.D 6PAitedt, Inspector: Date: 7) I I REINSPECTIO FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ff- A 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspgction Request Line (206) 431-2451 Project: ����� Type of Inspection: 760 Address: 11 5' i3 /Pi- • Date Called: Special Instructions: Date Wanted: 6/ i l l ‘.,r, Requester: r Phone No: ElApproved per applicable codes. t� Corrections required prior to approval. COMMENTS: aK. wioic scprirr Ltti .ot (1,..ociArnoiv) Date: 't f'3 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 613-037 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 f (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: �OPtia Type of Inspection: �na� i/ Address: X7)1.03-031 pi' Date Called: Special Instructions: Date Wanted: 4om.--) Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: AP- Inspector:11 n REINSPECTION FEE REQUIRED. Prior to paid at 6300 Southcenter Blvd.. Suite 100. Date: ki 1r 3 t next inspection. fee must be Call to schedule reinspection. SEA -TAC ELECTRIC, INC. COMMERCIAL • INUUSTRIAL May 23, 2013 To: Jim Benner—Electrical Inspector Project: Address: Permit #: Jim, Normed 4320 S 13e Place Tukwila, WA EL13-0437 Attached you will find my responses (in RED) to your plan review comments for the Normed project (Permit # EL13-0437). 1. Sheet E2.01 indicates 2 x 75 KVA transformers, E5.01 indicates 1 x 75 KVA and 1 x 45 KVA. Clarify. CM (SEI): THE CORRECT CONFIGURATION /S (1) 75KVA XFMR AND (1) 45KVA XFMR. ALL CHANGES HAVE BEEN CLOUDED AND ASSIGNED REVISION DELTA "1 ". 2. Sheet E2.01 indicates 2 x Panel H1. Show locations of Panels HSEH and HSEL. CM (SEI): THE DUPLICATE INSTANCE OF PANEL H1 ON THE MEZZANINE LEVEL HAS BEEN REMOVED. ADDITIONALLY, THE BUSS GUTTER, PANELS HSEH AND HSEL HAVE NOW BEEN SPOTTED UP ON PLANS FOR CLARIFICATION. ALL CHANGES HAVE BEEN CLOUDED AND ASSIGNED REVISION DELTA "1". 3. Ensure transformer secondary OCPD with 10 feet (conductor length) of transformers. CM (SEI): WE ARE LESS THAN 10'-0" ON THE SECONDARY SIDE FROM THE XFMR TO PANELS. I HAVE ADDED A 200A FUSED DISCONNECT NEXT TO THE XFMR TO COMPLY. ALL CHANGES HAVE BEEN CLOUDED AND ASSIGNED REVISION DELTA "/". 4. Sheet E5.01 — Confirm with PSE location of 480V service disconnects in relation to meters. CM (SEI): LOCATIONS HAVE BEEN MODIFIED BASED ON ACTUAL AND POTENTIAL INSTALLED CONDITIONS. ALL CHANGES HAVE BEEN CLOUDED AND ASSIGNED REVISION DELTA "1". 5. Sheet E6.01 (Flag note 1) Use of aluminum for ufer not permitted per NEC 250.52 (A)(3) and (B)(2). See also 250.66 (B). CM (SEI): DETAIL #4, #5 & #6 HAVE BEEN REMOVED FROM THE SET. THEY DO NOT PERTAIN TO THIS PROJECT. ALL CHANGES HAVE BEEN CLOUDED AND ASSIGNED REVISION DELTA "1". Thank you and please feel free to contact me with any questions comments or concerns. Best Regards, Corey McKinnon Senior Design Engineer, LEED AP BD+C Sea -Tac Electric, Inc. Phone: 253-872-5553 SmartPhone: 206-406-2801 Direct : 253-867-2354 Fax : 253-872-4112 Email: corey.m@seatacelectric.com CORRECTION ELVr 0`137 ! ECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER 7056 South 220th Street, Kent, WA 98032 1 253.872.5553 l Lq h, • City of Tukwila May 20, 2013 Corey McKinnon 7056 S 220 St Kent, WA 98032 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Electrical Permit Application Number EL13-0437 Normed — 4320 S 131 Place Dear Mr. McKinnon, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. Building Department: Jim Benner at 206 431-3679 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, hall cian File No. ELI3-04 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 AI Tukwila Building Division Jim Benner, Electrical Inspector Building Division Review Memo Date: May 17, 2013 Project Name: NORMED Permit #: EL13-0437 Plan Review: Jim Benner, Electrical Inspector The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11 x 17 to maximum size of 24x36; all sheets shall be the same size). Please include One Line Diagram, Load Summary, and Panel Directories (where applicable) 1. Sheet E2.01 indicates 2 x 75 KVA transformers, E5.01 indicates 1 x 75 KVA and 1 x 45 KVA. Clarify. 2. Sheet E2.01 indicates 2 x Panel H1. Show location of Panels HSEH and HSEL. 3. Ensure transformer secondary OCPD within 10 feet (conductor length) of transformers. 4. Sheet E5.01 —Confirm with PSE location of 480v service disconnects in relation to meters. 5. Sheet E6.01 (Flag note 1) Use of aluminum for Ufer not permitted per NEC 250.52 (A)(3) and (B)(2). See also 250.66 (B). Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. • pT ukilj? PLAN 1EW/ROUTING SLIP ACTIVITY NUMBER: EL13-0437 DATE: 05-23-13 PROJECT NAME: NORMED SITE ADDRESS: 4320 S 131 PL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Bull Ing Division Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05-28-13 Not Applicable n Comments: Permit'Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-25-13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit',Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 •ERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0437 DATE: 05/08/13 PROJECT NAME: NORMED SITE ADDRESS: 4320 S 131 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: cke.v\ieOk 11' P ilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05/09/13 Complete Incomplete ❑ Not Applicable ❑ Comments: Per►nit'Gen"tei Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route /, REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 06/06/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Pe nilt,Center Use.Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 1 Fire 0 Ping 0 PW 0 Staff Initials: DATE: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 5 •2 3/ 243-2, Plan Check/Permit Number: .51- / 3 - 0 11-37 Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ® Revision requested by a City Building Inspector or Plans Examiner Project Name: /170 F Project Address: 7' 20 s • / / 57- PL Contact Person: C.; "7F r / CKiNNO N Phone Number: (z 3) �'S6 7- -2-3y47/ Summary of Revision: HE-GED/ED erryor (uKWILA MAY 2 3 20131 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all das of revision'includiiig d eV. • Received at the City of Tukwila Permit Center by: --Entered in Permits Plus on H:\Applications\Fonns-Applications On Line '12010 Applications\7-2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7-2010 Contractors or Tradespeople Pr ter Friendly Page • Electrical Contractor A business licensed by L&l to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company SEA TAC ELECTRIC INC 2538725553 7056 S 220Th St Kent WA 98032 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601510212 Active SEATAEI077RW Electrical Contractor 12/16/1993 12/17/2013 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LIGHTSJ897QN LIGHTHORSE SEATAC JV Construction Contractor General Unused 11/9/2011 11/9/2013 Active SEATAEC131QC SEA TAC ELECTRICAL CONTRACTORS Electrical Contractor General Unused 11/3/1987 11/3/1995 Archived Master Electrician INFORMATION License HARGRT'974CD Name HARGREAVES, TOM Status Active Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM Agent 12/17/1993 Bond Amount HARGREAVES, TOM President 12/17/1993 798649C BEAN, ERIC Secretary 12/10/2008 BEAN, ERIC Treasurer 12/10/2008 MERCHANTS BONDING CO (MUTUAL) JORDAN, TOM Vice President 01/01/2002 01/22/2009 HARGREAVES, KATHERINE Secretary 12/17/1993 12/10/2008 BURKS, ROY Vice President 12/17/1993 12/15/1995 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 DEVELOPERS SURETY Et INDEM CO 798649C 12/16/2008 Until Cancelled $4,000.00 12/03/2008 5 MERCHANTS BONDING CO (MUTUAL) WA11373 12/16/2004 Until Cancelled 01/22/2009 $4,000.0012/17/2004 Assignment of Savings Information Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 12/16/1993 Until Released Bond $4,000.00 Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type httns://fortress.wa.!?ov/lni/bbip/Print.aspx 06/06/2013 5/23/2013 10:35 AM SYMBOLS & ABBREVIATIONS CIRCUITING SYMBOLS \\\ NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWG WIRE UNLESS NOTED OTHERWISE, NO HASH MARKS INDICATES TWO WIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH MARKS DENOTES NEUTRAL. —�-- INDICATES GROUND WIRE. INDICATES ISOLATED GROUND WIRE, WHERE SHOWN. NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. EXISTING RACEWAY OR WIRING- (IF HASH MARKS ARE SHOWN PULL NEW CONDUCTORS) RACEWAY STUB -OUT WITH BUSHING —► HOME RUN TO PANEL OR LOCATION NOTED —e CIRCUIT CONTINUATION 0/I-0 JUNCTION BOX, CEILING/WALL Pe PULL BOX HH HANDHOLE ----P/%/c---- UNDERGROUND UTILITY SERVICE - POWER, TELEPHONE & CABLE AS INDICATED OVERHEAD UTILITY SERVICE - POWER, TELEPHONE & CABLE AS INDICATED POWER POLE/GUY e-- G -e dts 4 0/4 6 4 45/4 VOb o 0 tM RA I� -o 16. GROUND WIRE IRREVERSIBLE COMPRESSION TYPE CONNECTION CADWELD TYPE GROUND CONNECTION GROUND TEST WELL GROUND ROD POWER SYMBOLS DUPLEX RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V DUPLEX / QUAD RECEPTACLE - EMERGENCY POWER DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE, STANDBY POWER DOUBLE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DEDICATED DUPLEX / QUAD RECEPTACLE DUPLEX RECEPTACLE - SAFETY TYPE DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFI DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ON PLAN - ATTACH TO DROP CORD FROM CEILING SINGLE RECEPTACLE 120V TRIPLE RECEPTACLE SPLIT SWITCHED DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED FLUSH MOUNTED CEILING RECEPTACLE PEDESTAL TYPE FLOOR BOX WITH DEVICES AS SHOWN FLUSH FLOOR POKE THROUGH - DEVICES AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED DRYER RECEPTACLE DISCONNECT SWITCH FUSED DISCONNECT MOTOR STARTER COMBINATION MOTOR STARTER, DISCONNECT MOTOR CONNECTION EQUIPMENT CONNECTION CLOCK HANGER AND OUTLET ON CRITICAL BRANCH CIRCUIT CONTACTOR MOTOR RATED SWITCH GENERATOR REMOTE ANNUNCIATOR PANEL PANEL - 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. PANEL - 480 VOLT SYSTEM, +6' TO TOP U.N.O. XX NL O a NL NL RISER SYMBOLS TRANSFER SWITCH CIRCUIT BREAKER DRAW OUT CIRCUIT BREAKER FEEDER DESIGNATION .-•-•-•{Em- FUSED SWITCH = GROUND PANEL PANEL {IIS GROUND FAULT CIRCUIT BREAKER TRANSFORMER CABLE TO BUS CONNECTION AVAILABLE SHORT CIRCUIT CURRENT METER O O DD DO >O FARA w► AID El EMC o—o O 0 O DTR CR DSI 04 E -i LIGHTING SYMBOLS FLUORESCENT FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE, "NL" INDICATES 24HR NIGHTLIGHT OPERATION FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FULL -SHADED FIXTURES SHALL BE CONNECTED TO STANDBY POWER SERVICE PANEL, "NL" INDICATES 24HR NIGHTLIGHT OPERATION HALF -SHADED FIXTURES SHALL HAVE INTEGRAL BATTERY BALLASTS "NL" INDICATES 24HR NIGHTLIGHT OPERATION POLE MOUNTED EXTERIOR LIGHT FIXTURE BATTERY PACK EMERGENCY LIGHTING UNIT BATTERY POWERED EXIT SIGN - ARROWS AS INDICATED, SHADING INDICATES SIDE(S) ILLUMINATED. BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, ARROWS AS INDICATED SINGLE POLE SWITCH (LETTER INDICATES SWITCH LEG) OCCUPANCY SENSOR WALL SWITCH 3 WAY SWITCH INCANDESCENT DIMMER/SWITCH FLUORESCENT DIMMER/SWITCH DAYLIGHT SENSOR, # INDICATES CONTROLLED CIRCUIT DESIGNATION CEILING OCCUPANCY SENSOR PHOTO -CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH TIMECLOCK FIXTURE PENDANT MOUNTED WALL SCONCE SURFACE MOUNT 2X4 TRACK LIGHTING SIGNAL & COMMUNICATION SYMBOLS MAGNETIC DOOR HOLD -OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. FIRE ALARM MANUAL STATION +48" SMOKE DETECTOR "D" SUBSCRIPT INDICATES DUCT DETECTOR "H" SUBSCRIPT INDICATES HEAT DETECTOR "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE TONE ALARM, BATTERY BACK-UP COMBINATION HORN/STROBE, WALL MOUNTED AT +80" UNLESS NOTED OTHERWISE COMBINATION HORN/STROBE, CEILING MOUNTED FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" UNLESS NOTED OTHERWISE FIRE ALARM STROBE ONLY, CEILING MOUNTED FIRE ALARM REMOTE ANNUNCIATOR PANEL TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" DATA OUTLET COMBINATION TELE/DATA OUTLET COMBINATION FIRE/SMOKE DAMPER CONNECTION MOTORIZED DAMPER - 120V MAGNETIC CONTACTS FOR WINDOW OR DOOR MONITORING PEDESTAL TYPE FLOOR BOX WITH DEVICE TYPE AS SHOWN CABLE RING ROUTE ELECTRIC CLOCK TV OUTLET CEILING MOUNTED SPEAKER WALL MOUNTED SPEAKER MICROPHONE TELEPHONE RISER FLOOR CORE FOR VOICE/DATA ONLY CARD READER AUDIBLE DOOR ALARM VOLUME CONTROL AT +54" EMERGENCY POWER OFF BUTTON SEPARATE PERMIT REQUIRED FOR: KMechanical 0 Electrical IR Plumbing tx Gas Piping City of Tukwila BUILDING DIVISION CALL SYSTEM RESIDENCE BATHROOM PULL CORD STATION RESIDENCE BED STATION CALL CORD RESIDENCE CALL/COMMUNICATION STATION CALL SYSTEM MASTER COMMUNICATION STATION CALL SYSTEM DOME LIGHT "Z" INDICATES ZONE DOME LIGHT DUTY STATION STAFF CALL STATION STAFF STATION • FLAG NOTE REVISION SYMBOL EXISTING EQUIPMENT OR DEVICE REMOVE EXISTING ELECTRICAL EQUIPMENT EQUIPMENT IDENTIFIER TYPICAL ROOM DETAIL REFERENCES: /1/ XXX 11012 MISCELLANEOUS XX - INDICATES DETAIL NUMBER M - INDICATES THAT DETAIL IS MIRROR IMAGE OF REFERENCED LOCATION EY.Y - INDICATES SHEET WHERE DETAIL IS FOUND DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN RELATION TO DETAIL PROPERTY LINE X-16-0- FENCING /A CABLE TRAY Q INDICATES COMBINATION POWER/TELE/DATA POKE-THRU FLUSH 0 FURNITURE FEED JUNTION BOX. ABBREVIATIONS AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR +6" ABOVE COUNTERS WITHOUT BACKSPLASH AFF ABOVE FINISHED FLOOR A, AMP AMPERE ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAGE (BTS) BASE TRANSFER STATION CB CIRCUIT BREAKER CKT CIRCUIT DED DEDICATED DW DISHWASHER (E) EXISTING EPO EMERGENCY POWER OFF EWC ELECTRIC WATER COOLER FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FI FILM ILLUMINATOR G, GND GROUND GD GARBAGE DISPOSAL GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT HWT HOT WATER TANK IGN IGNITION IH INSTA HOT J -BOX JUNCTION BOX MW MICROWAVE - COORDINATE MOUNTING HEIGHT N NEUTRAL NC NURSE CALL P POLE PNL PANEL PROVIDE FURNISH AND INSTALL (R) RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE -INSTALLED AS SHOWN) RO RACEWAY ONLY RECPT RECEPTACLE REF REFRIGERATOR S SAFETY TYPE SWBD SWITCHBOARD TELCO TELEPHONE COMPANY TELE TELEPHONE TR TELEPHONE RISER TYP TYPICAL UC UNDERCABINET UNO UNLESS NOTED OTHERWISE ✓ VOLT W WIRE OR WATT PHASE W/0 WITHOUT WP WEATHERPROOF COM NF NOTE REGARDING DRAWINGS: THESE DRAWINGS ARE PROVIDED FOR YOUR USE RELATING EXCLUSIVELY TO THE PROJECT CONTAINED HEREIN. SEA -TAC ELCTRIC, INC. PROVIDES THESE DRAWINGS WITH THE FOLLOWING STIPULATIONS: 1. THESE DRAWINGS, DOCUMENTS & DESIGN ARE PROTECTED BY THE RULES AND REGULATIONS OF U.S. COPYRIGHT LAWS. THE DESIGN IS AN UNPUBLISHED WORK AND SEA -TAC ELECTRIC, INC. RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17, SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THE DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 2. THESE DRAWINGS AND DOCUMENTS WERE COPIED FROM COMPUTER DATA CREATED AS A STEP IN THE PRODUCTION OF PHYSICAL DATA FOR THIS PROJECT. THERE MAY BE DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE COMPUTER DATA. WHERE SUCH DISCREPANCIES EXIST,- ONLY THE PHYSICAL DOCUMENTS AND DRAWINGS CAN BE RELIED ON TO REFLECT THE WORK OF SEA -TAC ELECTRIC, INC., WHO MAKES NO GUARANTEES OR WARRANTIES REGARDING THESE DOCUMENTS OR THE DATA THEREIN. 3. IN ACCEPTING THESE DOCUMENTS, YOU ASSUME ALL LIABILITY FOR THE ACCURACY, UTILITY, OR SUITABILITY FOR ANY PURPOSE FOR ANY DATA THESE DRAWINGS CONTAIN. IEWED .FOR LIANCE WITH A70 -NEC JUN 052013 City of BUILDING ila ISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY PermI NO. Il 1 Pian review approval is subject to errors and OMISSION. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie Copy and corand conditionsIs By Date City Of lawns ;.. BUILDING DIVISION CORRECTION DRAWING INDEX E0.01 - SYMBOLS & ABBREVIATIONS E0.02 - ELECTRICAL NOTES E0.03 - ELECTRICAL SCHEDULES E2.01 - GROUND FLOOR & MEZZANINE E3.01 - GROUND FLOOR & MEZZANINE E4.01 - GROUND FLOOR & MEZZANINE E5.01 - ONE -LINE RISER DIAGRAM E5.02 - PANEL SCHEDULES E6.01 - ELECTRICAL DETAILS 437 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER POWER PLAN LIGHTING PLAN MECHANICAL POWER PLAN w ((1) 2 w 0_ U z 0 F - w J w PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w w 0 12 O 2 Z� z z w REV # W U J N ornJ Cf) Q Cf) = J I—(i) O N ~ ce) DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 SYMBOLS & ABBREVIATIONS E0.01 5/23/2013 10:35 AM 0 W cn ea 0 i 0 F 0 w 0 O N N W cc0 ce a z w O a U O U N m O %= 1. GENERAL ELECTRICAL NOTES: EC SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND BE RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL THE FULL SCOPE OF WORK. IN ADDITION, THE EC SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. 2. EC SHALL COORDINATE WITH THE GC TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 3. EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE FOR APPROVAL AND SEE SPECS FOR FURTHER INFORMATION. 4. VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, OWNER OR OWNER'S REPRESENTATIVE AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. 5. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FOLLOW DRAWINGS IN LAYING OUT WORK AND COORD. WITH OTHER TRADES TO VERIFY SPACE CONDITIONS AND CLEARANCES. MAINTAIN HEADROOM AND SPACE CONDITION. MAKE APPROPRIATE ADJUSTMENTS AT OWNER OR OWNER'S CONTRACTOR'S DIRECTION. 6. COORDINATE WITH OTHER TRADES FOR ANY NEEDED LOW VOLTAGE CONTROL WIRING AND DEVICES THAT IS NEEDED BUT MAY NOT BE SHOWN IN THESE DRAWINGS. 7. TEMPORARY POWER: REUSE EXISTING PANEL (IF IN GOOD CONDITION) AND SERVICE FOR TEMPORARY CONSTRUCTION POWER. ALL RECEPTACLES TO BE USED DURING CONSTRUCTION SHALL BE GFI PROTECTED. 8. ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUITS LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. 9. THE EC SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) SHUTDOWNS WITH THE GENERAL. CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL SHUTDOWNS SHALL OCCUR BETWEEN 11: OOPM AND 5: OOAM. GENERAL NOTE:"CDNTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROVIIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. CODES PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MININUM STANDARD WITHOUT ANY EXTRA COST. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. LEED ALL WORK, MATERIALS AND EQUIPMENT SHALL MEET LEED REQUIREMENTS & CODE. IN CASE OF CONFLICT, THE HIGHER STANDARD SHALL APPLY. BASIC MATERIALS AND METHODS MATERIALS: PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED, LABELED, AND LISTED OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION FOR THE PURPOSE FOR WHICH THEY ARE USED. IN ADDITION, MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. NO SUBSTITUTION OF MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE. ALL ITEMS ARE NEW UNLESS OTHERWISE NOTED. CUTTING AND FITTING: PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE ARCHITECT, CONSTRUCTION MANAGER, GC, AND/OR OWNER. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. RACEWAYS PROVIDE CODE APPROVED WIRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT WITH COPPER CONDUCTORS OR MC CABLE (PROVIDED IT IS CONCEALED FROM VIEW AND NOT EXPOSED). ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID, MINIMUM 1/2" IN SIZE (UON). CONDUITS SHALL BE SIZED PER CODE AND AS NEEDED TO INSTALL CONDUCTORS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. PVC CONDUITS ARE NOT ALLOWED ABOVE SLAB UNLESS CODE AND AHJ APPROVED/LISTED FOR THAT USE. CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL CONDUIT WITH WEATHER TIGHT, CORRISION-RESISTANT FITTINGS (OR PVC WHERE LISTED FOR EXTERIOR -SUNLIGHT USE). CONDUIT SHALL NOT BE RUN EXPOSED WITHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER. WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRINGS END TO END WITH A LABEL ON BOTH ENDS STATING USE AND LOCATION OF OTHER STUB (E.G. DATA -FRONT POS). PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T&B FLAME SAFE OR OTHER METHOD APPROVED THE ARCHITECT AND AHJ. CONDUIT RUNS CONCEALED IN CONCRETE OR UNDERGROUND SHALL BE 3/4" MINIMUM, UNLESS OTHERWSE NOTED W/RIGID STEEL ELBOWS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. IF CONDUIT RACEWAYS CANNOT BE RECESSED IN WALLS DUE TO CONSTRUCTION OR EXISTING CONDITIONS, PROVIDE A STEEL SURFACE MOUNTED RACEWAY SYSTEM (WIREMOLD, HUBBEL OR APPROVED EQUAL) WITH ALL COMPATIBLE DEVICES. THIS TYPE OF SYSTEM IS ONLY ALLOWED WHERE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE INCLUDING LAYOUT. CONFIRM COLOR AND ANY CUSTOM FINISHES WITH OWNER OR OWNER'S REPRESENTATIVE. REVIEWEDFOR H COMPLIANCE -NEC NFP JUN 052013 City of Tukwila. BUILDING DIVISION CONDUCTORS AND TERMINATIONS CONDUCTORS: SHALL BE COPPER, INSULATED FOR 600V, TYPE THWN/THHN, NUMBER 12 AWG MIMIMUM UNO. MOTORS AND OTHER WIRING: THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WIRING, CONNECTIONS, AND SAFETY SWITCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN IF THE MOTORS AND EQUIPMENT ARE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. MAY BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL. ALL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH -IN. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES AND OTHERS DEFINED BY CODE, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND CONTINUITY. SWITCHES AND RECEPTACLES SWITCHES: GRADE OR APPROVED EQUAL WITH DURABLE COVERPLATES. COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE DM FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF SWITCH AND PLATE. RECEPTACLES: GRADE OR APPROVED EQUAL WITH DURABLE COVERPLATES. COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE DM FOR FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF RECEPTACLE AND PLATE. INSTALL RECEPTACLES PLUMB, LEVEL, AND SECURE TO J -BOX. PROVIDE GFCI TYPE WHERE INDICATED AND WHERE REQUIRED BY CODE AND AHJ. GFCI RECEPTACLES SHALL BE CLASS A RATED FOR PERSONNEL PROTECTION. ALL RECEPTACLES ARE TO BE MOUNTED 18" ABOVE FINISHED FLOOR TO CENTER OF DEVICE UNLESS NOTED OTHERWISE. OCCUPANCY SENSORS: SENSORSWITCH WSD SERIES FOR SINGLE OCCUPANT RESTROOMS AND CLOSETS AND SENSORSWITCH CONTRACTOR CHOSEN/OWNER APPROVED (PIR AND ULTRASONIC SOUND ACTIVATED) FOR PARTITIONED RESTROOMS. LOW VOLTAGE ALL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE (AND AHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALLED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH THE STATE AND AHJ REQUIREMENTS. ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND CABLING/CONDUCTORS SHALL BE LISTED FOR USE IN WET LOCATIONS, FOR LOW VOLTAGE APPLICATION AND PER AHJ. ALL LOW VOLTAGE CABLING ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS/CEILINGS IN A CONDUIT RACEWAY (UNLESS OWNER AND AHJ AUTHORIZE IT TO BE ROUTED EXPOSED THROUGH WALL/CEILING). IF APPROVED BY. OWNER & AHJ TO BE ROUTED EXPOSED, CABLING SHALL BE PROPERLY FASTENED/SUPPORTED PER CODE, AHJ, AND INDUSTRY STANDARDS. CABLING NOT ROUTED IN CONDUIT SHALL BE PLENUM RATED WHERE REQUIRED BY CODE OR AHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR PLENUM.) ALL LOW VOLTAGE CABLING OUTDOORS (E.G. ON ROOF) SHALL BE ROUTED IN CONDUIT PER CODE AND AHJ REQUIREMENTS UNLESS SPECIFICALLY LISTED AND LABELED FOR EXTERIOR USE. PANELBOARDS PANELBOARDS SHALL HAVE PLUG-IN OR BOLT ON BREAKERS AND MAIN LUGS ONLY OR MAIN BREAKERS AS NEEDED OR REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED WITH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 HOUSING (OR AS REQ'D BY CODE). ENCLOSURE(S) SHALL BE COMPLETE WITH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED CIRCUIT BREAKER DIRECTORY UNDER PLASTIC COVER IN EACH PANEL. ALL MULTIPLE POLE BREAKERS (AND OTHER BREAKERS REQ'D BY CODE) SHALL HAVE A COMMON TRIP HANDLE. FUSED SWITCHES FUSED SWITCHES: HEAVY DUTY TYPE, HORSE POWER RATED WITH INTERLOCKING COVER. NEMA 1 TYPICAL. OUTDOORS AND WET LOCATION SWITCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600A OR LESS SHALL BE UL CLASS RK1 DUAL -ELEMENT, 11ME DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITS RATED AT 601A OR LARGER SHALL BE UL CLASS L TIME -DELAY, CURRENT LIMITING SWITCHES. MOUNTING MOUNT DISCONNECTS TO STRUCTURE, INDEPENDENT OF THE MECHANICAL UNIT HOUSING OR WITH INDEPENDENT UNISTRUT SUPPORT. DISCONNECTS MOUNTED TO UNITS ARE ONLY ALLOWED WHERE ACCEPTED BY THE LOCAL CODE AUTHORITY AND LOCATED SO AS TO NOT BLOCK ACCESS OR LABELS OF UNIT. NAMEPLATES PROVIDE PHENOLIC NAMEPLATES ON ELECTRICAL DEVICES SUCH AS DISCONNECTS AND PANELS WITH THEIR DESIGNATION (E.G. "PANEL A"). PROVIDE DIRECTORY FOR PANELS AND LABEL ALL BREAKERS. IF A TRANSFORMER IS INSTALLED, PROVIDE NAMEPLATE ON TRANSFORMER AS FOLLOWS: "HOT SURFACE, DO NOT PLACE ANY ITEMS ON TOP OR ON SIDES OF TRANSFORMER". ELX 0H37 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER w (1) 2 w 0 PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w o 0 0 ZI- z z w REV # 4320 SOUTH 131ST PLACE DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 ELECTRICAL NOTES E0.02 JAMBS - CONTRACT - IN PROGRESS\IN-PROGRESS MNO\NORMED 11 - TUKWILA (13030)\SHOP DRAWINGS\CAD\E0.03.DWG 5/23/2013 10:35 AM , . Lighting Summary :20091/Va.shington State NonreSideritiM.Energy Ocide Compliance Forms LTG -INT Revised ;july:2009` Project Thlo Project Addr0sS. i-tAiRtie).- -TENANT IMP.ROVENREIsIT Date 5/23/2013 i432o souTh 13iST PLACE !TCKWILA, WA 98124 Applicant me:sEAc8a1Rc, Applicant Address': 7056s 220TH 6:1 - KENT, WA 98032 Applicatt Phone-. (253): 872-5553 ; For Building Department Use Project Description I ! ntsfew Building LIAdclition I 'Alteration , ansinci0ded Refer to WSEC Section 1513 for Controls and ccirrimissioning requirements. Campliarie Option • riPrescriptiVe I ElLighiting.Power Allow ance-LISyStems AtialySis (See Qualification Checklist (over). Indate--Pre.scriptive & LPA -spaces clearly on plans.) Alteration::EXceptions1 l'40 changes are being made to the lighting' )c he c k 3'ipio 10 pria i a b ai' sec • 1132 . b): n Less than 60% of fixtures neWinstalled lighting w attage is nofincreased, and space use is not Changed ,. Maximum Allowed Li King Wattage (Interior Location (floor/Mom no.) betuponcy Description :Allowed WattS-perfii** Area in 2 Allowed x Area GROUI%3 FLOOR OFFICE •" I 0.9 4119.0 3707.1 NIEZZAPOW OFFICE 0.9 2762.0 2485.8 7From Table 15-1 (alter) - Occurrent all exceptiOns on Tarn t_TGLI=54. Proposed LightingWattage Totals 6881.0 6192.9 Lor aim .„ .„.„. (flea/room no) ... .... „ ; r.:Fixture Description : i l NOmber of : ;F'idureS Watts/ Fixture ; : Watts Proposed TYPE PI -2X4 RECESSED FDCTLRE - 2L F32T8 i -:, I 39 58 BAST : 2262.0 FLAG NOTES FIX ;.2X.4 RECESSED FIXTLOIE - 2L F32T8 6 58 1 c 290.0 F1 F2. I 2X2 RECESSED FIXTLRE - 2L Fl7T8 ; 21 34 ELECTRONIC <10%THD I 714.0 F3 'EXPLOSION PROOF LIWAR FIXTURE- 2L F3218 ; 2 58 I F32T8 116.0 58 F4 ICI-RINI-OP FIXTLIRE. 2L F32T8 f f i. 7 58 ' 2 406.0 ELECTRONIC <10%THD F5 '-DECORATIV EWALL SCONCE - 2L 13W TT , I ; ; 5 26 1 HL-HFX-265 130.0 2 F6 W• RECE3SED CAN - 1L 26W Ci : , : 19 26 F4 LIGHTOLIER 494.0 277 F6X ! 6'.7 RECESSED CAN -: IL 26W CFI_ i I 4 26 I 104.0 6737WH F7 WALL MOW" FLUORESCENT if AlSTY-.1LF32T8 1 30 ! . 30.0 F6 F8 t WALL iviotkoFLUORESCENTVAMIY- 11 F32T8 ' 2 30 26W CFL , 60.0 NEW FLUORESCENT 6" RECESSED CAN LIGHT, CLEAR IRIDESCENCE FREE, WHITE FLANGE F9 ; WALL motgsrr FLUORESCENT II AMTY - IL' PI7T8 ''. 0 15 277 1 0.0 ELECTRONIC <10%THD F10 I:CONIskIGHT - 1L 32W CFL, VWDIMMINGEALLAST ' 5 32 OXYGEN LIGHTING ' 160.0 1 FIOX ;DCWIsLIGI-IT - IL 32W CFL Wi DIMMINO I3ALLAST I 3 32 i 96.0 HORIZON 2-587-224 ).( :POT SIGN 1 :1 7 5 NEW WALL MOUNTED FLUORESCENT VANITY FIXTURE 35.0 OXYGEN LIGHTING HORIZON 2-583-224 277 1 F171-8 ELECTRONIC <10%THD 15 NEW WALL MOUNTED FLUORESCENT VANITY FIXTURE Total Proposed Watts may not exceed Teta! Allow ed Watts for Interior : Total Proposed Watts KONE II MODEL 622 ; 4897.0 , . . . . „ .„..„...... MECHANICAL EQUIPMENT CONNECTION SCHEDULE ELECTRICAL DATA DISCONNECT INDIVIDUAL EQUI PMENT I NFORMATION TOTAL MANUFACTURER UNIT INFO TYPE FRAME FUSE SUPPLIED BY MARK AREA SERVED LOCATION VOLT PH QTY kva FLA 1 HP FLA KVA MCA MOCP FiNIF NEMA SIZE AMP ELECT MECH ELECT NOTES - ;.... - ••'!. -- • . ROOFTOP.UNIT:.$CtiEDULE - • RTU ROOF 480 3 11.639 14.0 11.64 - 14 20 F 3R 20 20 X 3 RTU 2 ROOF 480 9.145 1.00 .9.15 11. 15 F 3R 15 15 X 3 RTU 3 ROOF -480:. 11.639 14.00 11.64 14 20 F 3R 20 20 .x 3 RTU :4 ROOF 480 3 1 11.639 14,00: • 11.64 14 20 F 3R 211 20 X 3 EXHAUST FAN SCHEDULE EF BREAK 206 CEILING 120 0.168 1.40 017 : NF X 1,2 EF 2 RESTROOM 202 CEILING 120 0.071 0.59 0.07 NF X 1,2 EF :3 WOMEN 111 CEI LING 120 0.168 -1,40 NF 1 x 1,2 EF MEN 112 CEI LINO 120 1 0.168 1.40 0.17 NF 1 X 1,2 EF BREAK 113 CEILI NG 120 0.168 0.17, NF 1 X 1,2 EF 16 SERVER 106 CEILING 120 1 0.216 Lao NE 1 X EF I 7 SCREEN PRINTING 113 CEILING 120 1 0.216 Imo NF X 1,2 NOTES . . 1 FOR 120V FANS PROVIDE MOTOR RATED SWITCH FOR LOCAL DISCONNECT WHERE REQUIRED 2 • EXHAUST FAN CONTROLLED BY LIGHT SWITCH , 3 PROVIDE HACR RATED BREAKER AT PANEL OR LOCAL FUSED DISCONNECT AT UNIT IN LIEU OF NON-FUSED REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC -JUN -0 5 2013 -- City of Tukwila BUILDING DIVISION LIGHT FIXTURE SCHEDULE LAMP TYPE MANUFACTURER(CATALOG SERIES NO. NO.) VOLT NO. TYPE BAST FIXTURE WATTS DESCRIPTION FLAG NOTES INTERIOR LIGHTING .-' ' .:. • : „.. F1 LIGHTOLIER H9S2GLR232 277 2 F32T8 ELECTRONIC <10%THD 58 NEW TWO LAMP 2X41 FLUORESCENT FIXTURE FIX LIGHTOLIER H9S2GLR232 277 2 F32T8 ELECTRONIC <10%THD 58 SAME AS FIXTURE "Fl" ONLY WITH INTEGRAL BATTERY BALLAST F2 LIGHTOLIER H9S2GLR2I7 277 2 F171-8 ELECTRONIC <10%THD 34 NEWTWO LAMP 2X2 FLUORESCENT FIXTURE F3 HUBBELL HL-HFX-265 277 2 F32T8 ELECTRONIC <10%THD 58 NEW TWO LAMP EXPLOSION PROOF LINEAR FLUORESCENT FIXTURE F4 LIGHTOLIER KW4S232 277 -2 F32T8 ELECTRONIC <10%THD 58 NEW CHAIN HUNG FLUORESCENT LIGHT FIXTURE W/ WIRE GUARD & CHAIN HANGER KIT F5 LIGHTOLIER 6737WH 277 2 13W TWIN TUBE ELECTRONIC <10%THD 26 NEW DECORATIVE WALL SCONCE FIXTURE F6 LIGHTOLIER 8031 CLW 277 26W CFL ELECTRONIC <10%THD 26 NEW FLUORESCENT 6" RECESSED CAN LIGHT, CLEAR IRIDESCENCE FREE, WHITE FLANGE F6X LIGHTOLIER 8031 CLW 277 1 26W CFL ELECTRONIC <10%THD 26 SAME AS FIXTURE "F6" ONLY WITH INTEGRAL BATTERY BALLAST ' F7 OXYGEN LIGHTING HORIZON 2-583-224 277 1 F32T8 ELECTRONIC <10%THD 30 NEW WALL MOUNTED FLUORESCENT VANITY FIXTURE F8 OXYGEN LIGHTING HORIZON 2-587-224 277 1 F32T8 ELECTRONIC <10%THD 30 NEW WALL MOUNTED FLUORESCENT VANITY FIXTURE F9 OXYGEN LIGHTING HORIZON 2-583-224 277 1 F171-8 ELECTRONIC <10%THD 15 NEW WALL MOUNTED FLUORESCENT VANITY FIXTURE F10 DELRAY LIGHTING KONE II MODEL 622 277 1 32W CFL ELECTRONIC <10%THD 32 DOWN LIGHT VVITH D9 DIMNIING BALLAST FIOX DELRAY LIGHTING KONE II MODEL622 277 1 32W CFL ELECTRONIC <10%THD 32 SAME AS FIXTURE "F10" ONLY WITH INTEGRAL BATTERY BALLAST X LITHON IA BWE-GEL-N-M6 277 LED 5 NEW EXIT SIGN W/ GREEN LETTERS GENERAL NOTES 1. ALL INDICATED CATALOG NUMBERS REPRESENT A DESIGN BASIS ONLY AND CORRESPOND TO THE LISTED MANUFACTURERS SERIES NUMBER. ALL OPTIONS, ACCESSORIES AND/OR FIXTURE COMPONENTS MAY NOT BE REFLECTED IN THIS NUMBER AND CONTRACTOR RESPONSIBLE FOR -PROVIDING ALL SUCH ITEMS DISCLOSED IN FIXTURE DESCRIPTION AND/OR SPECIFICATIONS. SUBSTITUTION OF FIXTURE TYPES WILL ONLY BE ACCEPTED IF PHOTOMETRICS, CONSTRUCTION/COMPONENT QUALITY AND DESIGN INTEGRITY ARE SHOWN TO BE EQUAL TO THE DESIGN INTENT. FINAL DISCRETION TO BE DETERMINED BY ENGINEER. ALL SUBSTITUTIONS SHALL INCLUDE PHOTO METRICS AND BE RECEIVED (5) BUSINESS DAYS PRIORTO CLOSING FOR ENGINEERING ANALYSIS 2. PROVIDE COLD WEATHER BALLASTS FOR ALL OUTDOOR FIXTURES. 3. ALL FLUORESCENT AND HID LIGHTING FIXTURES SHALL BE PROVIDED WITH IN-LINE GLR-FUSE. 4. CONTRACTOR TO VERIFY CEILING CONDITIONS FOR PROPER MOUNTING HARDWARE 5 WHERE- F IXTURES ARE SHOWN SHADED PROVIDE BATTERY BALLAST W ITH REMOTE TEST BUTTON. 01137 RECEIVED CITY OF TUKWILA MAY 23 2013 PERMIT CENTER 0 -J Lr;) c\i co ec7,3z - w 0 a. 7056 SOUTH 220TH STREET C‘I Cs.1 N. co c'1 LL KENT, WA 98032 0>z w w Lu 0 r -t 0 z w REV # 4320 SOUTH 131ST PLACE CN CO _J DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 ELECTRICAL SCHEDULES E0.03 JAMBS - CONTRACT - IN PROGRESS\IN-PROGRESS MNO\NORMED 11 - TUKWILA (13030)\SHOP DRAWINGS\CAD\E2.01.DWG 5/23/2013 10:35 AM 1 r - -1 II I J L_J r L � GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. MULTI -WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS. 3. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE AS SELECTED BY THE ARCHITECT, U.N.0.. VERIFY WITH ARCHITECT PRIOR TO ORDERING. 4. COORDINATE ALL CABLE PATHWAY ROUTING IN STRUCTURE, FINISHES AND OTHER TRADES PRIOR TO ROUGH -IN. 5. EQUIPMENT SHOWN BOLD IS NEW. 6. EQUIPMENT SHOWN DASHED IS EXISTING. 111 01 1114 4 44 I 1 L_J I L_J EL L1 C 1+2) I L_ I I 48 JVO III , 30 L1 I I 4► ° 1p148 -ice - 11 L_JL_ Dll�o161I11111111 19 1]). vR' SCALE: / -0" FLAG NOTES: FLUSH MOUNT DEVICE TO ALLOW FOR TWO DUPLEX AND ONE VOICE/ DATA CONNECTION PER WORK STA11ON SHOWN. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION AND REQUIREMENTS OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. WALL MOUNTED WHIP FEED CONNECTION TO FURNITURE ALLOW FOR TWO DUPLEX AND ONE VOICE/ DATA CONNECTION PER WORK STA11ON SHOWN. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION AND REQUIREMENTS OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. SERVER ROOM: COORDINATE POWER, COMMUNICATION, AND BTU OUTPUT WITH TENANT, ASSUME A MINIMUM OF (1) 30 AMP DEDICATED OUTLET AND VOICE/ DATA OUTLET FOR SERVER RACK, J -BOX FOR COAX CABLE CONNECTION, (3) DEDICATED OUTLETS. PROVIDE 4' X 8' FIRE RATED PHONE BOARD WITH PAINT FINISH TO MATCH ADJACENT PARTITION. NEW OUTLET TO BE 220V. OUTLET TO BE FED FROM J -BOX WITH RIGID CONDUIT. REVIEWED FOR: COMPLIANCE ECTH NfPA70 N JUN 05 2013 CI of Tukwila BUILDING VISION J -BOX FOR COAXIAL CABLE CONNECTION. MEZZANINE POWER PLAN SCALE: 1/8" = 1'-0" EL13O 437 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER U z U_ F- 0 - U w J w PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w w� O 2 z� Z z w REV # DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 GROUND FLOOR AND MEZZANINE POWER PLAN E2.01 M 0 M N M 0 0 W 0 a 0 0 0 0 cn ce ce a . 0 iri - J L_J CD L GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. MULTI—WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS. 3. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE AS SELECTED BY THE ARCHITECT, U.N.0.. VERIFY WITH ARCHITECT PRIOR TO ORDERING. 4. COORDINATE ALL CABLE PATHWAY ROUTING IN STRUCTURE, FINISHES AND OTHER TRADES PRIOR TO ROUGH—IN. 5. EQUIPMENT SHOWN BOLD IS NEW. 6. EQUIPMENT SHOWN DASHED IS EXISTING. +7 p(PA EL L1 SSC 1+2) NI ll!II111111 I L r- -i L L -1 1111 ■11 IL 1 :v ■a■ V diMMON 141■ 1■■rmi � 1 �1-XII 21 ■N mad ims impompl• ■_,gm ■■! J■■C ■11111L I. 1■ 1 1111111161� f o. IJi �■� Iii ���� Im��� _mom um mi min IIIIIIIIIIIIIIIIIIIIIIMI C� i i °Y 1 1 D D 1 D .D 1 i Alimminor �i " Cis 'i iimmimuC in 1111 LILA imailliromn I NM x® SCALE: / -0" H I 1 L_J ENERGY CODE NOTES: 1. ALL LIGHTING NOT INDICATED AS A 24—HOUR NIGHT LIGHT SHALL BE CONTROLLED BY TIMECLOCK OR OCCUPANCY SENSORS. ALL LOCAL SWITCHES SHALL BE DOWNSTREAM OF AUTOMATIC CONTROLS. 2. COMMISSIONING REQUIREMENTS: IN ACCORDANCE WITH WSEC 1513.7, ALL AUTOMATIC LIGHTING CONTROLS (INCLUDING TIMERS & OCCUPANCY SENSORS) SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 3. LIGHTING IN STAIRWELLS SHALL HAVE ONE OR MORE CONTROL DEVICES TO AUTOMATICALLY REDUCE LIGHTING POWER IN ANY ONE CONTROLLED ZONE BY AT LEAST 50% WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THAT CONTROLLED ZONE. FOR FURTHER CLARIFICATION REFER TO WAC 1513.6.1. FLAG NOTES: SWITCH FOR EXHAUST FAN LIGHT IN THIS ROOM TO BE ON TIMER WITH EXHAUST FAN REVIEWED w� H COMPLIA NFPA 70 - NEC JUN 05 2013 City of Tukwila BUILDING DIVISIQN _. Mmir 1■■1 NEW . -, .oI■ ©■■I■ ■I■ 1111 ■ 1it ' ■I■•■■■I■•!g• ■■ ■■■■I■ot�.ii ■1 ■ , e ■■I ■m■I■ �� IfrI!L jjj ■1 •■14;■uI■■■I■ �,%A rmit FrEgitil III amtmmare H1-3 H1-3 H1-3 H1-3 I IMMAMEMIrommill■■ 1111 �i11164 11111 111:111111 IMISUPIPI I I 1 3a 111/ Som m. m li j / iiiiiiiiiiinipe( MEZZANINE LIGHTING PLAN SCALE: 1/8" = 1'-0" ELfl 0437 RECEIVED CITY OF TUKWILA MAY 232013 PERMIT CENTER H W (o 2 12 w 0 U z 0 0 w J w PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w w 0 ct O 2 ZF z z w REV # DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 GROUND FLOOR AND MEZZANINE LIGHTING PLAN E3.01 z/./Fe �,., IMMAMEMIrommill■■ 1111 �i11164 11111 111:111111 IMISUPIPI I I 1 3a 111/ Som m. m li j / iiiiiiiiiiinipe( MEZZANINE LIGHTING PLAN SCALE: 1/8" = 1'-0" ELfl 0437 RECEIVED CITY OF TUKWILA MAY 232013 PERMIT CENTER H W (o 2 12 w 0 U z 0 0 w J w PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w w 0 ct O 2 ZF z z w REV # DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 GROUND FLOOR AND MEZZANINE LIGHTING PLAN E3.01 r 600A BUSS GUTTER GROUND F SCALE 1/8" = 1'- " LOOR MECHANICAL POWER PLAN r� f GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. MULTI -WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS. 3. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE AS SELECTED BY THE ARCHITECT, U.N.0.. VERIFY WITH ARCHITECT PRIOR TO ORDERING. 4. COORDINATE ALL CABLE PATHWAY ROUTING IN STRUCTURE, FINISHES AND OTHER TRADES PRIOR TO ROUGH -IN. 5. EQUIPMENT SHOWN BOLD IS NEW. 6. EQUIPMENT SHOWN DASHED IS EXISTING. 7. MECHANICAL CONTRACTOR TO PROVIDE ALL LOW VOLTAGE CONTROL WIRING, CONDUIT TO BE PROVIDED BY SEA -TAC ELECTRIC, INC. 8. SEA -TAC ELECTRIC, INC. TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS AND STARTERS FOR MECHANICAL EQUIPMENT. 9. SEA -TAC ELECTRIC, INC. TO INTERLOCK BATHROOM FANS WITH LIGHT SWITCH. 10. SEA -TAC ELECTRIC, INC. TO PROVIDE GFCI OUTLET WITHIN 25'-0" OF EACH PIECE OF MECHANICAL EQUIPMENT. T —�l I I L_J CF -1 *#4 AL I 1---1 L_JLI REVIEW.FOR W TH COMPLIANCE NFPA 70 - NEC JUN 052013 City of Tukwila BUILDING DIVISION -8 UH -1 H1-8, 10,12 H1-14, 16,18 EF -1 1" CONDUIT H1- (4) #4 AL (1) #8G AL f4 AL\ ' 2,4,6 FLAG NOTES: 25' TAP RULE APPLIES. CONTRACTOR TO ROUTE ACCORDINGLY AND ADJUST FOR FIELD CONDITIONS AS REQUIRED. INTERLOCK BATHROOM FANS WITH LIGHT SWITCH. SERVER ROOM FAN TO BE CONTROLLED BY THERMOSTAT. CONFIRM EQUIPMENT SIZE AND LOCATION WITH OWNER OR OWNER(S) REPRESENTATIVE PRIOR TO ANY ROUGH -IN. EF -2 1 RTU - / iiia. -i ire 01/4 6 C 4 AL 11D R1U-3 MEZZANINE MECHANICAL POWER PLAN SCALE: 1/8" = 1'-0" E 0437 RECEIVED CITY OF TUKWILA MAY 232013 PERMIT CENTEFI W (1) 2 w 0 U z ct U w J w M N ti co l[) w z 0 a 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w w 0 O 2 ZF z z w REV # DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 GROUND FLOOR & MEZZANINE MECHANICAL POWER PLAN E4.01 0 M N eqeq cn0 I ce 0 a 0 i M M v cnJ Y I F 0 W 0 0 Z 0 a N a a U O - FEEDER SCHEDULE ALUMINUM ID NO P..APRVVIAT <WIRE;GOUNT:. MPACI Y/ 03N .................... 03.. 04N 05N 05. 06N ©7N...... ............ ......................... 7 :08N ,.... 10N 10 ....................................... 12N.... 12 13w .............. -15N ........ 15.. ..... 18N 18. 20N...... 20, 22N ......................................... 22 25N ......._ .......................... . 25 .................................... 27N 30N........._. 34N .34 40N 40..,... 45N .. 45 50N 50... 80N- 60 ..... 75N 75 80N'... 80. 90N 90 100N 100 1264 120 ............................ 150N 150 1.60N 1'60 200..... 3/4" .............. 3/4" 2, 2 112" ..:.:...:....................:...... 2" 2'1/2" 2 1/2" 2 1/2" ................................... 2 1/2" 3:r...,.. ............... .. ............. 21 /2" ............: 3" 21/2" 3,' .. 3" 3 1/2" 3".. (2)2112" (2) 2 :1/2" (2)2112" "(2).2'1 /2" (2) 2 1/2" ............. (2) 3! (2) 3'.:,. (3) 2.1/2" (3)2 1/2" (3) 3" (3) 3" (3) 2 1/2"_.. (3) 3" (4)3" (4)3"............ (5) 3" (0) 3" ...:...............:................ 6)21/2.".v, .(6) 2 (8)3" 4 #8, 1#8 :G: 3 -#8 1#8 G. 4-.46; 1#8 G: 3-#6, 1#8 0: 4-04, 1#8.G........... '3 -.#4, '1##8 G. 4 43, 1#8 G. 3 -#3, 1#8.G ....... ..... 3 -#2, 1##6 G: 4 -#1, '1#6 0: ................................................................................. :3 ..#1, 1#6' G_ 4_#1/01#6G_ ........ 3 - )46.'6 • 4 -#1/0, 1#4 G. 3 - #110, 1#4 G. 4-#2/0,.1#4G. 4 - #3/0,...1:#4:0... _.. 3 - #310, 1.#4 G. 4-#410,1#4 G'. 344/0, 4-250kcm II, 1 #4.0. 3-250kcmil, 1 #4 G. 4-300kcmil, 1 #2 G. 3-3.0.0kcrnII, 1 #2 0. • 4-350k 'rail, 1 #2:G_ 3-350kcmil, 1 #2 0. ............. . 4-400kcrriil, 1 #2 L. 3..-4.00kcmil; 1 #2 G.. 4-500kcm.il, 1 #2 G. 3-500kcrgil, 1 #2 G. 4600kcmi1, 1 #1.C.7- 3 600kcmiC, 1 #1 G. 4 250kcmil, .1 #1 G. 3 2501cmil, 1 #1 G. 4-300kcrnil, 1 #110-0; "3=300kcmil, 1' -.#1/0.6. . ............................ 4-350kcmil, 1 #1/9 G, 3-350kcmil, 1 #1/06, 4-500kemil,.1. #2/0 G_. 3 500kcnril, 1 #210.0„, 4 350kentil, 1 #310 6_ 3-350kcmil, 1. -#3/iib. 4-40akcnril, 1 #310:G. 3400kcmil,.1 #310 G. 4-500kcrnil, 1 #4/0 G. 3-5001ccmil,.1 #4/0 G. '4-600k6tnil, 1 #4/0 G. 3-800kcm il,, 1 ##410 6.. 4-500kcm if, 1 #250 G; 3-500kcm.il; 1:#250:0. 4-500kcir il, '1. #350'G. 3 500kcm:il; 1 4-400kcmil, 1 #350 0. 4-3-400kcmil, 1 #350 G. 6©Okcm il, 1 #400 G. ...........................:........ ................ 3-600kcmil, 1 #400.G. 301:30 301:'30............ 4Q 140....... 40/40 /50.... 55 / 50 651.60 .. . 65/60' 75'/ 70 75. / 70 85'/ 80 ........................................ 65 /' 80 1.20:1100 120/10 201 110 1201'110 135 / 125..... 135 / 925 155:1150 155 ;11.50 180 / 175 ..:..::................. 980 /175 205 / 200 ..................................... . 205 / 200 '16.7 225 2301225 250/250 2501250 2701250 270. /. 250. 310/ 300 310/300 340:1 300 '340 / 300 410 / 400 4.10 / 400 460. / 450 460 / 450 ........................ 500 / 500 500''/ 500 600 625 / 600 750 750 / 750 810 / 800.._._.... 810/800 930 / 900 9301 950 1020 / 1000 1020 / 1000 12401 1200 1240/.1200.. :1654/1 ......... 5a0 i 55Q/1500 1820(1800 1620/1600 •264612606- 2040/2000 040/20002040/2000 604ieg'rating 60 -deb rating 60 -deg rating 60-rleg rating 60 -deg rating 60 -deg rating :............:.....:.................. ............. 60 -deg.. rating .............._ . 60 -deg rating 6c -deg rating .:...,:.,,_. 60deg rating 60 -deg rating ..........:.........................:........................... 6a-deg,.rating 75-de9 :rating ............... . ting 15 -deg rating 75 -deg rating 75-1eg rating 75-0a9 .rating 754 g rating . 75 -deg .rating.. _.................... ................ . 7:5 -deg rating .............................................................. 75=deg rating 75-dsg'rating 75 -deg rating_... 75 -deg rating 75 -deg rating ..............................:.................................... . 759eg rating 75,ieg rating ............. 75 -deg rating .......:.......:....................... ........................ 75 deg rating. .75 -deg rating 75 -deg :rating 75 -de g..rating... _............... 75 -deg rating 75 -der rating 75 -deg rating 75 -deg rating 75 -deg :rating 75 -deg rating .......................... 75 -deg rating 755 -deg rating 75-1eg rating 75 -deg rating 75 -deg rating 75 -deg rating 75 -deg :rating 75 -deg rating 75 -deg rating 75 -deg 'rating 75-dag rating 75 -deg rating 75 -deg rating 75 -deg rating .........._......._ 75 -deg, rating 75 -deg rating __....... 75 -deg :rating 75 -deg rating 75 -deg rating.... . . 75-dag, raying NATE �i sed::on' TI HN:irlsuiatl#d� EMI cond.ult-arid'IfhaRte49. 3'abte 4 and Tabid 5a for.00mpact ALwrre; ofthe.NEC; 2008 drtlpa * - Indicates aceeptable overaurrent device rating forsingle feeder. This..rating,shall' not be. used, forsiziiig'parallei.; feeders_ -.indicates avercurrent. protective device rating that maybe' used for this feeder. The Contractor shall install feeder size indicated evef:if Code allows smallerto be used. GRADE PSE UTILITY TRANSFORMER 1. GENERAL NOTES: ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED 'WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. RISER DIAGRAM IS NOT REPRESENTATIVE OF ACTUAL SWITCHBOARD LAYOUT. SEE ELECTRICAL ROOM (SHEET E2.01) AND PANEL SCHEDULES (SHEET E5.02) FOR PHYSICAL LAYOUT WITH RESPECT TO ACTUAL MANUFACTURED AND POTENTIAL INSTALLED CONDITIONS. 3. 4. 5. 6. EXTERIOR INTERIOR NEMA 3R NEMA 1 EQUIPMENT SHOWN BOLD IS NEW. EQUIPMENT SHOWN DASHED IS EXISTING. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NEC 408.4(B). PANEL HSEH MLO 100A PANEL HSEL MCB 100A PANEL H1 MLO 200A 45kVA XFMR X5kV FM II i VREVIEWED FON COMPLIANCE VgITH NFPA70 JUN 05 2013 City of Tukw 'la jolNGDIVt0N ROOF PANEL PANEL L1 L1 (SEC1) (SEC2) MLO MLO 200A 200A #4G HOUSE 200A 200AF SUITE 100 --J--- SVC. DISC. 100AF TENANT METER SVC. DISC. 200A 200AF BUSS GUTTER 600A, 480Y/277V, 30, 4W UTILITY PRIMARY a- - - - - - XFMR VAULT J 3 SETS) 2-1/2" PVC-40 4) 250 KCMIL AL EA. UTILITY SERVICE POINT ONE -LINE RISER DIAGRAM SCALE: NTS ELECTRICAL ROOM ELI'r0�137 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER w w 0 U z U ce U w J w PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w w0 02 z� Z w REV # DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 ONE -LINE RISER DIAGRAM E5.01 PANEL SCHEDULE PANEL:' BUSS -GUTTER we.0... TYPE : EXISTING 0 ..NEW 0 LOCATION:': ELECTRICAL ROOM :STYLE:. VOLTS:; 480 Y; 277, P 3 W:'4 AIC RATING: MOUNT:®SURFACE 0 FLUSH NEUTRAL; .10044. ,_... FED FROM I :UTILCFY, CIRCUET DESCRIPTION LOAD TYPE LOAD CKT KVA BKR P C1R P CIR H # CKT BKR LOAD KVA, PANEL HSEH" • COMB COMB 100 3 3 A 2 4 200 35,42 37.53 COMB 5 6 34.54 LOAD TYPE COMB COMB COMB CIRCUIT DESCRIPTION PANEL -11 ESTIM&TEDMXItI.JMDEMfND (EMD) CALCULATIONS CONNECTED LOAD SUMMARY: LIGHTING RESIDENT LTGRECPT SMALL APPLIANGE LARGEST MOTOR REMAINING MOTORS I MTR GEN PURPOSE COMPUTERRECPT: , MISC EQUP1OTHE€2I MISC, HEATING, • I MISC ELEVATOR: ELEV KITCHEN EQPT KITCH.. • TOTALS; LOAD TYPE::: . • LTG :RES LOAD TYPE NOTES: 'CONE"= COMBNATION LOAD TYPES ON INDICATED CIRCUIT "RES"=:RESIDENTIAL LTGREGPT OR SMALLAPPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC" =EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUITAT 100% 4.90KVA 0.00 I KVA 0.00 1KVA 0.00 ;KVA 5.33:_KVA 17.82 :KVA 8.64 :KVA 14.82'KVA._ --` 4898 ; KVA_ 4.00 I.KVA 10,00 'KVA 10149 'KVA 129.29 1AMPS E.M.D. CALCULATED 6.12 KVA (125%) 0.00 KVA (100135/25 %,) 0.00 KVA (100135/25 %) 0.00 1KVA {125%) 5.33 KVA (100%) 13.91: KVA (50% > 10KVA) 8.64 ' KVA (100%) 14.82 KVA (100%) 45.98 KVA (100%) 0.00 ' KVA,@_ 100% 6.50 :KVA @ 65% 101,30 ;KVA 121.85 ',AMPS CONNECTED PHASE LOADING PHASE A: ' 35.42' KVA PHASE B: 37:53; KVA PHASE C:: 34.54' KVA GENERAL NOTES: 1 PER NEC 2104IA) & (B) ALL MULTWIRE BRANCH CIRCUITS SHARING A COMMON NEUTRAL WIRE MUST BE PROVIDED WmAMEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT. THE POINT OF ORIGIN. CONTRACTOR'S CHOICE: •PRGyp E SEPARATE NEUTRALS :FOR BREAKER AS INDICATE, OR, PRO'IDE•MULTIPOLE BREAKER FOR SHARED NEUTRAL, • • FLAG NOTES: REVIEWED W TH COMPLIANCE NFPATO - NEC JUN 0 5 2013 GI'h10f Tll Mils BUILDING DIVISION PANEL SCHEDULE PANEL:: HSEH Anr>P:,10.0 .....: 1111-131:1 MCB..D TYPE: ... EXISTING0. N LTG -SUITEB LTG =SUITE B LTG-SUITEB CIRCUIT DESCRIPTION LOCATION: STYLE: LOAD ........... TYPE LOAD ..:........ KVA LTG =E3(TERIO. RWALLPACKS LTG -EXTERIORWALL PACKS - LTG ,ENTRY :............................._................ ........:.----- LTG-8QL_LARDS SPACE SPACE SPACE.,.:.: .., . SPACE • SPA.CE. SPACE SPACE . SPACE SPACE SPACE SPACE _..__. SPACE .............................. SPACE CKT BKR 20 20 20 20 20 20 20 1 VOLTS: 480 ' YI AIC RATING:' 14,000.. NEUTRAL: '100% CTR 1 3 •5 1 7. _.. 9 11 13 15' 17 21 2 25_.... 27_ 29 31 _...,. 33 35.,.. 37.. 39 41 P C A B C A B C A B 277 P:3 8:: 10 12._... 14. 16 18 20...... 22 24 LOAD TYPE W: 4 MOUNT•. ® SURFACE 0 FED FRONt BUSSGUI lER CIRCUIT DESCRIPTION SPACE SPACE SPACE SPACE SPACE SPACE SPACE .:...,_, SPACE SPACE 28 30 32...... 34.... 36 38 40 42 SPACE SPACE SPACE SPACE SPACE. SPACE SPACE ESTIMATED''MAXIMUM DEMAND (Es/p) CALCULATIONS LOAD SUMMARY: :LOAD LIGHTING LTG RESIDENT LTGJRECPT 'RES SMALLAPPLJANCE I; :RES' LARGEST MOTOR I REMAINING MOTORS MTR GEN PURPOSE RECPT I REC- COMPUTERRECPT! MISC IMISC HEATING...... ...:MISC ELEVATOR,,. • ELEV • KITCHEN EQPT........' .._._....._......` KITCN PE: CONNECTED 0.00 KVA__....; 0.00 •KVA ......... 0.00 _KVA Apo :KVA • 0DO: KVA..... 0.00: KVA.......: o.30KVA....... 0.00...: KVA.......' ,,,,0.00 KVA 11.00 KVA 0.00,: KVA E,10. CALCULATED 0.00 I KVA 025%) 0;00 KVA (100135125 %) 030 KVA (100/35/25 %) 0,00 'KVA (125%) 0.00. ' KVA (100%) 0.00 •KVA..(50% > 10KVA) 0.00'KVA(100°%) , .. 0.00 KVA (100%). 0.00 .KVA (190%). 0.90 :KVA 10J% 000. KVA @. 65% 030.KVA P-00 .._ AMPS.:..I..... 0:00' ; KVf1 0.00... AMPS...,..., .., CONNECTED PHASE LOADING PHASE A:;...009 KVA ..._:. PHASE B: 0.00; KVA PHASE C: 0.00; KVA GENERAL NOTES: 1 PER NEC 21040 & (B) /LL MILTIWIREBRANCH CIRCUITS SHARING ACOMMJN NEUTRAL WIRE ;MOST BE PROVIDED WITHANEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED ;CONDUCTORS AT THE POINT OF ORIGIN. *CO NCRPCTOR'SCHOICE. PROAADESEPARATE NEUTRALS -FOR BREAKER AS INDICATED OR PROMDEMULTIPOLE BREAKER FOR SHARED NEUTRAL. LOAD TYPE NOTES: "COMB" COMBINATION LOAD TYPES ON INDICATED CIRCUIT .. "RES".=::RESI©ENTfAL LTGIRECPTOR-SMALLAPPLIANCE LOAD TAKEN ATINDICATED DEMAND "MSC"=1 EQUIP, COMPUTER REC OR HTO LOAD ON INDICATED CIRCUIT AT 100% PANEL SCHEDULE PANEL:; HEEL A :._1.0.Q........?..M.O EJ MCB TYPE:,; EXISTING' NE LOCATION: ELECTRICAL ROOM .... ... . STYLE;_ VOLTS: 208 AIC RATING: 10.000_ NEUTRAL: `100% Y/ 120 P 3 W::4 MOUNT: X SURFACE FED FROM PANELHSEH CIRCUIT DESCRIPTION LOAD TYPE LOAD • KVA CKT SKR P CIR P 11 CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION REC-SUfTsB. REC -SUPT-.6^T REC-SUFTEB REC -SUITE B REG -SUITED REC -SUITE B REC - SU rt'E 737 SPACE. ; I SPACE. SPACE SPACE -- SPACE SPACE SPACE SPACE SPACE SPACE SPACE I SPACE SPACE ESTIIUTATED M&XIMUMDEMAND (ERR) CALCULATIONS LOAD SUMMARY: `LOAD TYP€ PGHTING. I :LTG RESIDENTLTGIRECPT -RES S.M LAPPLLANCE ' RES LARGEST MOTOR REMAINING.MQTORS MTR GEN PURPOSE'RE.CPT :REC COMPUTER RECPT .MISC EQUIPIOTIIER,.. ,., " . . ;MISC ... HEATING ; •10C ELEVATOR .ELEV Kl7CHEN EQPT :KrrcH, ;TOTALS; D TYPE NOTES: "CCiBW COMBINATION, LOAD TYPES ON INDICATED CIRCUIT, "RES"= RESIDENTIAL'LTGrRECPTORSMALL APPLIANCE LOAD TAKEN ATINDICATE " NISC' EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100% REC REC REC ............... RE C REC REC REC REC 0.54 1.08 0.72 20 20 20 0.72 20 1.08 20 0:94 .._ 20 0.54 20 0.54 20 3 5 7 1 9 1 11 .___......._13.._.. 15._.. 17......... 19 21 25 27 29 31........... 33 :35.......... 37 39 41 ECIED E.M.D. CALCULATED 0.00 KVA 0.00 i KVA (125%) _ 0.00 KVA 0.00 ;KVA (10013525 %) 0.00 KVA 0.00 ;KVA (100/35125 %) 0.40 KVA 0.50 'KVA (125%) 1.60 :KVA 160 KVA 0.60$0.. 990 KVA 9.90 KVA(50%>10KVA) 0.00 KVA 0.00IKVA(1-0%) 030 KVA 0.99 ;KVA(100%). 0.00 KVA 0.00 ;KVA.('104%) 0.00 KVA...._.... _...... 0,00 !KVA...100% ,0.00 KVA 0.00 KVA cz ; 350.5 1.,90 :KVA 12.00 • KVA 3.03 „AMPS 33.31 'AMPS' B C A B C A B 2 4 86 10 12 14 16, 18 20 20 20...... 29 20 .............. 20........ 220......., 20 . 20...... 20 ................ 20 1.08 REC 1.08 REC 0.54 -REC 0.36 REC 0.72 REC .._.... 040.._....._...._.._MTR.._..,., 0.40......._ ....._._._MTR..._._ ....._Q:40....._....._..._MIR .......... 0.40 MTR 0.40 MTR REC- SUITE A REC -SUITE A REC -SUITE A REC -SUITE: A REC -SUITE A...._......_ CEILING FAN - CEILING FAN - CEILING FAN CEILING FAN CEILING FAN 42 SPACE SPACE SPACE SPACE ._............... SPACE - SPACE SPACE SPACE SPACE SPACE SPACE CONNECTED PHASE LOADING PHASE A: 404 KVA PHASE B:. 4.90 KVA PHASE C• 2.96 KVA GENERAL NOTES: - PER NEC 210.4( & (0) MJLTIWE OCH CIRCUT-S-SHNGAC0MN NEUTRAL WIRE MUST BE PROVIDED WITH A IVEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGRG UNDER CONDUCTORS AT' THE POINT:OF ORIGIN. CONfRACTORSCHOICE: PRO\IDESEPARATENEUTRALS FORBREAKER,!S INIDIC'TEU OR_PROM.D.E MULTIPOLE PR. EAJER,FOR SHARED NEUTRAL FLAG NOTES: PANEL: H1 AMP 200. M.O Q M 8 TYPE EXISTINGNEIN X CIRCUIT DE SCRIPTION LOCATION: SUITE 100 STYLE;. PANEL SCHEDULE LOAD LOAD CKT TYPE KVA BKR P VOLTS; 480 AIC RATING: 14,000 NEUTRAL;: 100% OR CIR Y( P 277, P CKT BKR LOAD KVA LOAD TYPE W: 4 MOUNT.: ® SURFACE FED FRONt BUSS GUTTER . -CIRCUIT DESCRIPTION LTG -GROUND FLOOR (FLAG'NOTE #1) LTG -MEZZANINE (FLAG NOTE #1) SPACE • SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE : SPACE SPACE SPACE SPACE • SPACE SPACE SPACE SPACE SPACE 2.82 20 1 3 5 7 A A B C A B C A B C B C A 34 3 60 20 20 100 B 14.69 MISC 14.69 MISC 14.69 0:58 0:58 0,58 0.50 0.58 .............. ................................ 0.58 MISC MTR ................ MTR ................... MTR. MIR,. MTR .................... MTR RTU -1, RTU2, RTU -3, RTU<t CF -1 ` .............. CF -2 SPACE ....................... SPACE ....................... SPACE SPACE SPACE SPACE ....................... SPACE SPACE SPACE 16.74 COMB PANEL 11 ' 19.60 COMB 18.69 COMB - ESTIMATED MAXIMUMDEMAND (ElI+D)CALCULATIONS LOAD SUMMARY; .LOAD TYPE: LIGHTING i LTG RESIDENTLTGIRECPT 'RES SMALL,APPLJANCE I RES LARGEST MOTOR REMAINING MOTORS MTR GEN PURPOSE RECPT :REC COMPUTERRECPT, MISC EQUIP/OTHER MISC HEATING MISC ELEVATOR ELEV KITCHEN EQPT KITCH ;TOTA'LS' :LOAD TYPE NOTES:, "CONE" _ :COMBINATION LOAD TYPES .DPI INDICATED CIRCUIT "RES"-=' RESIDENl1AL LTC-)REC PT OR SMALL APPLINCE LOAD TAKEN AT INDICATED DEMAND "MSG" =:EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUITAT 100%: CONNECTED E.RLD: CALCULATED - 4.90 KVA 6.12- KVA (125%), 0.00 KVA. 0.00 KVA ( 104135/20%)_ 0.00 KVA 0.00 : KVA ( 10 0/35125 %) 1.75 KVA. • 3.58 KVA 1782 KVA 8.64 KVA 14.82 KVA 45.98KVA ... 0.00 KVA 10.00:KVA 107.49 KVA 129,29 _: AMPS _ 219 KVA (125%) 3.58 -- KVA (190%), .. 13.91 KVA (59% > 864:KVA (100%) 14.82 KVA(100%) 4598 I KVA (100%) ___ 000;KVA(ui ,100% 550 KVA @ ;63% 101.74: KVA 122.37: AMPS..... CONNECTED PHASE LOADING PHASEA:: 35.42 KVA PHASE B:. 37.53; KVA PHASE C: `. 34.541KVA GENERAL NOTES: 1 PER NEC 210.4(A) & Of ALL MULTIWIRE BRANCH CIRCUITS SHARING AC0PJ 10N NEUTRAL WIRE= MIST BE PROVIDED WITH AMEAJS THAT WILL SINULTAI`IEOUSLY DISCONNECT ALL UNGROUNDED ,_ .,,., CONDUCTORS AT THE POINT OF ORIGIN CONT Ric TOR'SCHOICE: PROVIDE. SEPARATE NEUTRALS ;FOR BREAKER AS INDICATED OR PROVIDE MULTIPOLE BREAKER FOR SHARED NEUTRAL FLAG N 1 'INTERLOCOTES.K BATHROOM FANS WITH LIGHT SWITCH PANEL:. Ll (SEC 1) ANP: '200 MO 0 :MCB TYPE EXISTING 0 NEW 0 PANEL SCHEDULE VOLTS: 208 Y/ : 124 P 3 AIC RATING: 10,000 NEUTRAL: -1O4% W: 4 MOUNT ; ® SURFACE FED FROM PANEL H1 CIRCUIT DESCRIPTION : LOAD TYPE LOAD KVA CKT SKR P OR P CIR P CKT @KR LOAD KVA LOAD TYPE .. CIRCUIT DESCRIPTION PAICROWAVE-BREAK 206 REFRIGERATOR -BREAK 206 VENDING MACHINE - BREAK 206 REC -BREAK 206. HALL 200 REG -OFFICE 205 : KITCH KITCH KITCH REC REC REC _STORAGE 201, RESTROO6-1202 : .---_ _-.. NEC ._. REC _(DED)- CONFERENCE 203 ;,. MSC REC -CONFERENCE203 ---..._..:...._...._REC.__ REC FLOOR BOX -CONFERENCE 203: REG REC -OFFICE 109. ' NEC REC-OFFICE 108 : REC -OFFICE 107 RECSDEDI,OFFICE107 I : NEC (DED) -OFFICE 107 REC @ED} -SERVER 106 REC(DED)-SERVER106.__ RECSDEDT _SERVER 106- .___.._._._. REC.(DED) SEFi1ER-o& SPACE• REO. 208 )., BACK OF HOUSE REC„ REC REC REC MISC MISC MISC MISC MISC MISC 1.00 100....... 1.00 0.36...... 0.72 0.36 0.50 0.90y 0.18 1,08 0.72 0.72 ._ 1.44 1.44 2.16 216 2.16_. 2.16 2.15 2.16 20 20._.. 24_.. 20 .. 20 20 ... 20 20 20 20 20,.. 20 20_. 20 30 20 20.,... 20 20 1 1 1 1 1 1 2 3 5 7 9 11 13 15 17 19 21. 23 25 27 29 31 33. 35 37 39 41 A A A A 2 4 6 8 10 12 14 16 18 20 24 26 28 30 32 34 38 40 42 1 1 1 1 1 1 1 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 30 0.73 024 1.92 0.32 0.32 1.50 1,50 1.50 1.50 1.59 1.50 1.08 0.72 0.90 1.00 1.08 1.08 225 2 25 MIR NITR MIR MISQ MTR MISG MSC MISC MISC REC REC REG MISC REC REG CF -1 CF -2 SYSTEM S .FURNITURE -OPEN OFFICE 104 SYSTEMS Fu RN I TURE OPEN OFFICE 104_ ... SYSTEMS FURNITURE -OPEN OFFICE 104 SYSTEMS FURNITURE -OPEN OFFICE 104 SYSTEMS FURNITURE -OPEN OFFICE' '104 KITCH KITCH RE C - OPEN OFFICE /04 RE C - CONFERENCE 110, JANITOR CLST 114, BAck OF COPIER - OPEN OFFICE 104 SPACE . WATER NEATER EsTINIATERK4mmUm pg NO (END)CRLCULATIONS LOAD SUMMARY: LIGHTING RESIDENT LTG/RECPT SMALL APPLIANCE ! LARGEST MOTOR • COMPUTER RECPT MISC EQUIPADIFIER MISC ELEvAidi KITCHEN EQPT KiTCH _! LOAD TYPE: LTG RES RES CORRECTED CALCULATED 17.82 KVA a91 KVAX 59% OKVA) 55.03 KVA 52.75 AMPS 4_OAD TYPE NOTES: 'COMB" = COMBINATION LOAD TYpES ON INDICATED CIRCUIT "RES!,'77:KplpgNTIALI.TpKoF,roR SMALL ApPLANCE LOAD TAKEN AT INDICATEDDEMAND inic.=.EQUIP COMPUTER REC OR HTG LOAD ON INDICATED CIRCUITAT100% 47.70 KVA 132A0 AMPS CONNECTED PHASE LOADING PHASE B: 19.60!KVA! !PHASE e: 18.69i KVA. GENERAL NOTES: 1 210,41,A) & (p) tvIULT.IWIRE BRANCH -CIRCUITS Sf-AARIIG A ONAION NEUTRAL WIRE :NUST BE PROVIDED WITH A MEANS THAT WILL SIMATANE.OUSLY DISCONNECT ALL UNGROUNDED icoNpucipps AT THE pOINT OF 0 RIGN. CONTRACT2RS CHOICE; PROVIDE SEPARATE NEUTRALS .FOR BREAKER AS INDICATED OR PROVIDE MULTPOLEBREAKER FOR SHARED NEUTRA„ LOCATION: SUITE 100 P EL SCHEDULE STYLE: VOLTS: .208 Ale RATING: 10300 NEUTRAL: 100% MOUNT: 0 SURFACE El FLUSH CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA SKR CIR SKR LOAD KVA LOAD TYPE MICROWAVE - BREAK 113 REC - BREAK 113, RECEPTION 101 REG -CONFERENCE 103, TESTING -102, LOBBY 100 A SPACE • SPACE ! SPACE SPACE KITCH REC 1.26 1.08 20 20 20 1 1 ESTIMATED lk*XIMLIM DEMAND pm) pALc [RATION 4:. 43 A 45 B 47 C 49 A 51 Es 55 A 57 59 c 61 A LOAD SUMMARY: LOAD TYPE: LIGHTING ; LTG RESIDENT LTGRECPT RES SMALL APPLIANCE RES LARGEST MOTOR REMAINING MOTORS .MTR COMPUTER RECPT misc; Eouipio-o-i ER MISC. ELEVATOR !ELEV KITCHEN EQPT KITCH TOTALS LOAD TYPE NOTES: - RE.SIDENTIAL umpEciTr PR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND "Mk" = !EQUIP, COMPUTER REG ORNTG LOAD ON INDICATED CIRCUIT AT 1005' CONNECTED 7.54 !KVA EAU. CALCULATED 6.67 KVA 29 93 AMpS 1850 :AMPS ! 45 48 50 52 54 56 58 60 62 g9 0.90 REC RE C - SCREEN PRINTING 115 20 0.90 REC RE C - BACK OF HOUSE 0.90 REC REC - BACK OF HOUSE SPACE SPACE SPACE SPACE SPACE SPACE CONNECTED PHASE LOADING PHASE Li: 2.40 KyA GENERAL NOTE . PER NEC 210A(A) & (B) ALL MULTIWIRE BRANCH c!Rp.q7s SHAFT ACONNION NEUTRAL WIRE CONDUCTORS AT THE POINT OF ORIGIN CONTRACTOR'S CHOICE: PROVIDE SEPARATE NEUTRALS FLAG NOTES: RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER co a. oct (/) PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 0 > u. 0 ce ct (1- 0 2 0 cp DATE 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 PANEL SCHEDULES E5.02 Co 0 M O CVM 0 0 G Z a ce 0 0 0 a O M v TYPE 1 DA\LL 'TB o 208Y/120V 3PH 4W o FED FROM 'HD' NORMAL BRANCH FOR PANELBOARDS AND ATS TYPE 2 DA\FL 'TBD' o 480/277V 3PH 4W FED FROM UTILITY #1 NORMAL BRANCH FOR SWITCHBOARDS AND TRANSFORMERS GENERAL NOTES: 1. SECURE NAMEPLATE TO SURFACES. 2. NAMEPLATE TO BE 1/16" PHENOLIC PLASTIC LAMINATE WITH COLORS AS FOLLOWS "NORMAL BRANCH": FACE TO BE BLACK, ENGRAVED LETTERS TO BE WHITE. PANEL NAME IDENTIFICATION DETAIL SCALE: NTS 1. NEUTRAL LINE BLACK NEUTRAL WHITE GROUND GREEN 0 4 RED GENERAL NOTES: EMERGENCY BATTERY PACKS (WHERE INDICATED ON PLANS) SHALL BE PROVIDED AN UNSWITCHED 'EMERGENCY BRANCH' PHASE CONDUCTOR IN ADDITION TO THE SWITCH LEG OF THE SAME CIRCUIT. WIRING DIAGRAM -OCCUPANCY SENSING WALL SWITCH SCALE: NTS TYPICAL DRY TYPE TRANSFORMER 480V DELTA PRIMARY 208Y/120V SECONDARY. SEE SPECIFICATIONS. LINE SIDE SIZE PER NEC TABLE 250-122 L1 L2 L3 GROUND 0 0 • TRANSFORMER HOUSING TO ELECTRICAL ROOM GROUND BUS. ALSO, BOND TO NEAREST AVAILABLE POINT OF THE INTERIOR METAL WATER PIPING SYSTEM IN THE AREA SERVED BY TRANSFORMER. SIZE PER NEC TABLE 250-66 LOAD SIDE CONTINUOUS GREEN GROUND CONDUCTOR SIZED PER NEC TABLE 250-66. FURNISH AND INSTALL AN ALUMINUM EQUIPMENT GROUND BAR KIT WITH INDIVIDUAL TERMINALS FOR EACH GROUNDING CONDUCTOR. SECURELY MOUNT IN ACCESSIBLE SPACE AT TRANSFORMER TERMINAL COMPARTMENT. SIZE GROUND BAR KIT TO ACCOMMODATE MAXIMUM AND MINIMUM GROUND CONDUCTOR SIZES FOR EACH GROUND TERMINAL TYPICAL TRANSFORMER GROUNDING DETAIL SCALE: NTS REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUN 05 2013 City of Tukwila BUILDING DIVISION �L1'3 0437 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER w 07 2 w 0 U Z U U w J w PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 z w w w� 2ce°- 02 z� Z Z W REV # DATE n 05/23/2013 DRAWN CM CHECKED CM DATE 05/23/2013 ELECTRICAL DETAILS E6.01