Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL13-0505 - ZALES - TENANT IMPROVEMENT
ZALES 1000 SOUTHCENTER MALL EL1 3-0505 City ogukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 1000 SOUTHCENTER MALL TUKW Project Name: ZALES Permit Number: EL13-0505 Issue Date: 09/04/2013 Permit Expires On: 03/03/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: AMY SITYMANSKI Address: 319 ELAINES CT , DODGEVILLE WA, 53533 Contractor: Name: STAR ELECTRIC SERVICES INC Address: 14219 20TH PL W , LYNNWOOD WA 98087 Contractor License No: STAREES937NA Phone: 608-319-2096 X8 Phone: (425)879-9133 Expiration Date: 08/08/2015 DESCRIPTION OF WORK: TENANT IMPROVEMENT Value of Electrical: NRES: $21,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: PUGET SOUND ENERGY n Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $630.13 2008 Date: l L_ 13 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction pr11' performapce of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: (1/// /fidzeZZi Date: �3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL13-0505 Printed: 09-04-2013 PERMIT CONDITIONS Permit No. EL13-0505 **ELECTRICAL** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. ioc: EL -4/10 EL13-0505 Printed: 09-04-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenier Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. E-1--c---03-05- Project No. Date Application Accepted: Date Application Expires: 5 �-3 ► \\ ( (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION DP Site Addres` '6blE) §_.)14.4-111e*► ( 111211 /Lt KWi Ltin- 910 King Co Assessor's Tax No.: Suite Number: 05/ a Floor: / New Tenant: ❑ Yes..No Tenant Name: 701'05 PROPERTY OWNER Name:`/ 5Gl yr ,i5k i Name: /t'? Lc p City:� et,Itatl : 4'ir-3) Address: ,5x al-1iCo vt Aer Eniail: 04,iV(2 .0arr4)4, Cam City: 5 State: £ ,n Zip:(Qj�' CONTACT PERSON — person receiving all project communication Name:`/ 5Gl yr ,i5k i Address:5/9 (Qi Ko. _ yi t � p City:� et,Itatl : 4'ir-3) Phone 664'3/9-a09(oX, Fax:epo5r 319- /1 - Eniail: 04,iV(2 .0arr4)4, Cam ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: . City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Co, Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change 1159 Remodel ❑ Tenant Improvement 0 Low Voltage 0 Generator ❑ Fire Alarm ❑ Telecommunication 0 Temporary Service Property Served by: ❑ Puget Sound Energy 0 Seattle City Light H:Wpplications\Forms-Applications On Lme\201 I Applications \Electrical Permit Application Revised 8-9-I l.docx Revised: August 2011 bh Page 1 of 2 RES, DLN'1'IAI. NEV\' RESIDE:NTIAI. SE:1t\'IC'1•: ❑ New single Tamil) ti Rings . .SI52.85 (including an attached garage) ❑ Garages, pools. spas and outbuildings Sg1,90 ca ❑ 1 IA% %oltage systems (alarm. furnace thermostat) S59.R5 ca RESIDENTIAL RE\EODE:t. A\1) SERVICE CHANGES ❑ Service change or alteration S8 (.90 (no added/altered circuits) ❑ -Service change Niilh added/altered circuits 581.90 number of added circuits 41 1.55 ca ❑ Circuits addtdtattcrcd without service change 554.60 (up to 5 circuits) ❑ Circuits added/altered without service change 55.1.60 (6 or more circuits) 5+7.65 ca ❑ Nletcrnhast repair 568.25 ❑ Lu\ voltage %)stems 459,85 (alarm. funiace thermostat) Nl I'LTI-FA %IIL'i AND COMMERCIAL. Fees are based on the %;attrition of the electrical contract. \IIS('1.1.1..A\FDPs FE LS ❑ Temporary ser ice (residential) 463.011 O Temporary ser\icc(generator) 57X 75 O Manufactured/mobile home service 58.1.1111 (excluding garage or outbuilding) ❑ Carnivals 578.75 Number of concessions 510.50 ca PERMIT APPLICATION NOTES - Value of Construction - In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time int an additional period not to exceed 90 da) s. The extension shall be requested in writing and justifiable cause demonstrated. 1 IIERFBY CFR11FY MAT 1 IIA\'L REAL) ANI) EXAMINED flits APPLICATION AND KNO\V Tilt: SAME TO BE TRUE. UNIMR I'ENAI.TY OF PERJI IR( BY THE LAWS OF TIW STA.'''. OF WASHINGTON. ANI) I AM AlIT' MIMED TO APPLY FOR TIIIS PERM) 1 BUILDING OVINE OR EI.E(" 1 IC., L C()'IFRA(-'1'OR: Signature: Print Name: Hj yls/ ���1t/il iQ1t`)I.-1 Mailing Address: 75/6) n. r) C1;„"1( H 5;'(.71.1:.. . rt+ rg 'ttc.nt,�n. /bel.:+<:�tt t l:�di. at.,un 2'le.tn:s! I mt Rctuca ,tu L•i A.11 Iti �.atf.•. H r. Date: Day Telephone: [16-31 I` f;519% /mob i) 3 ) Stair Jtp I'.Igc_2ot2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0505 Address: 1000 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/23/2013 Applicant: ZALES Issue Date: Receipt No.: R13-02543 Payment Amount: $516.70 Initials: WER Payment Date: 09/04/2013 02:33 PM User ID: 1655 Balance: $0.00 Payee: DIMITRIY NEDZELSKIY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 023217 ACCOUNT ITEM LIST: Description 516.70 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 516.70 Total: $516.70 .dnn• Denefn+ lla Printprl• n9-04-9013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0505 Address: 1000 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/23/2013 Applicant: ZALES Issue Date: Receipt No.: R13-01726 Payment Amount: $113.43 Initials: WER Payment Date: 05/23/2013 11:32 AM User ID: 1655 Balance: $453.70 Payee: STATE PERMITS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13659 113.43 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 113.43 Total: $113.43 .,1..... DnnetnI (1R Printed. 05-23-2013 INSPE TION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: zi Type of Inspection: L „ i Address:Int- /DooDate Iht, Called: Special Instructions: Date Wanted: `' o /�„. Requester: Phone No: Approved per applicable codes. Ll Corrections required prior to approval. OMMENTS: Okslial rIAD6 r Inspector: Nil n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ((107 13 7 INSPECTION RECORD Retain a copy: with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILABUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: @OiR "q3 6c- {atoJ o to P4 J(L- Address: /000 PIA s Date Called: ' rliSSI of 4 C+ Co ti 6cite-(951 Special Instructions: • Date Wanted: Ika ti.. ac Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - fidalvhkf CAlkoiin 744-- @OiR "q3 6c- {atoJ o to P4 J(L- BQ tAkdba GLAIP . 'dor- Locic.. DOS ' rliSSI of 4 C+ Co ti 6cite-(951 Inspector: Date:PIO (13 n REINSPECTION FEE REQUIR]:D. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 6_ -0.5-05-- 6 INSPECTtION`RECORD Retain a copyfwith permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Project: s' ,'Jt/T1 dkr CACAPTS (Ai PRL Type of Inspection: Zr BD Address: oOO r t4�N l � fZQ.AtASj) Ak_. -}--46144.64\ Date Called: Cfs'n C's f 14— f. Ct . r4A-5 WeaSf Special Instructions: ` Date Wanted: tt 10S—p i Requester: Phone No: ElApproved per applicable codes. ,Corrections required prior to approval. COMMENTS: s' ,'Jt/T1 dkr CACAPTS (Ai PRL r Z9-0141\ IWnithe DesCa V t & F & • Mvl.Ti iJIPE�etkc4itr3 r t4�N l � fZQ.AtASj) Ak_. -}--46144.64\ Cfs'n C's f 14— f. Ct . r4A-5 WeaSf 41J4/JsrAti,,scur5 4& R4r..Ac ' f o ahtiJ i O�cSA Zest -5 5SI/J�S L) Qo c /6L lr r t . A `�t� rN A Inspector: Date: °sh3 REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD. Retain a copy with permit P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:07 kJIS16-5 Type of Inspection: 70©3 EN Address:Date /OOo, Called: Special Instructions: Date Wanted: 2, a.m. p.m. Requester: Phone No: ElApproved per applicable codes. COMMENTS: ki(b-r „(Npick i Corrections required prior to approval. /e; Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ERMIT NO. CITY OF TUKWILA BUILDING DIVISION �! 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: .7.04,45Type of Inspection: 70 - Address: Iron Date Called: Special Instructions: Date Wanted: /0/0 a:m. l� Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - - 1 -1A -Rpt -9 Inspector: Date: tQ . ,Jn9 L� r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD (1 Retain a copy with permit W 3 ds�. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367.0 Permit Inspection Request Line (206) 431-2451 - Project: � � KVL Type of Inspection: 00 Address:/Ooo /� F Date Called: Special Instructions: 1 Date Wanted: a / °/�0 p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: b/tta A$ ya4E:.D &ndiNit'f Co Q� 6kit of kca-s5 wee_ves Inspector: Date: REINSPECTION FEE REQUI ED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 645-05Dc Project: Type of Inspection: 7003/700 Address: 1000 1A1.A./. Date Called: Special Instructions. Date Wanted: j40 / 1 .m p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. fL COMMENTS: 072al____ , 0 I 700 7* e t.t o nl5 rG 0 i i Ai -- ukh-Lit.„ ez./act — 6ivniitoort(1-64c141 Inspector: iliC4Alet\ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: /0/01// INSPECTION RECORD Retain a copy with permit i INSPECTION NO. 63-6Or PERMIT NO. ,CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: 4 7 ,5 Address: /000 414r Date Called: Special Instructions: Date Wanted::m: Requester: Phone No: LjApproved per applicable codes. Corrections required prior to approval. /.-- COMMENTS: VI - .1 0 - — S7bfJr 5oifir Ar6r) C2iun(l5 CoWcriod5 et,d1,r g.0415 7,0 gfi 3tQo ) e 5 of( cesS Q L O w ' i f1d i'911 old '1C ' o/ TU� f - do pt/G— lel c_6144JA Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100.. Call to schedule reinspection. Total Allowed Watts 2009 Washington State -rgy Code Compliance Form for Nonresidential r • Multifamily Residential Interior Lighting Sun1rnary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address #C312 SOUTHCENTER MALL Date 5/17/2013 2800 SOUTHCENTER MALL For Building Department Use �.., Prt� �® . 1)1 TUXWILA, WA 98188 Applicant Name: Zales Applicant Address: p....,,,,,,,_ Applicant Phone: 6971 Project Description ❑ Plans Included requirements. ❑ New Building ❑ Addition -' Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed LJ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2 "" Gross Interior Area in ft2 Allowed x Area RETAIL 3.83 1820 6971 FIXTURE TYPE A2 COMPLIANCE WITH 26 90 2340 FIXTURE TYPE A3 NFPA - NFC 70NFC From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage 6971 Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed FIXTURE TYPE Al I REVIEWED FQh 7 45 315 FIXTURE TYPE A2 COMPLIANCE WITH 26 90 2340 FIXTURE TYPE A3 NFPA - NFC 70NFC 8 135 1080 FIXTURE TYPE B AND B2 8 42 336 FIXTURE TYPE D UN 0 5 2013 8 79 632 FIXTURE TYPE F4 AND F4E 3 64 192 FIXTURE TYPE ZP_ 2 64 128 CV of -Tukwila _ BUILDING DIVISION Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 5023 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. EL 13-. 0505 RECEIVED CITY OF TUKWILA MAY 13 2013 PERMIT CENTER aJ 2009 Washington Stanergy Code Compliance Form for NonresidentiaaieLd Multifamily Residential Lighting, Motor, ant. -Transformer Permit Plans.6hecklist LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address #C312 SOUTHCENTER MALL Date 5/17/2013 The following information is in the 2009 Washington State necessary to check a Nonresidential Energy permit application for compliance with the lighting, motor, and transformer requirements Code. Applicabil(ttyz\ rte Fv=�ra ,(yes, no, n.a.) 1 Co e� ; . Section Component, till Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control/access Schedule with type, indicate locations E1.0 Yes 1513.2 Area controls Maximum limit per switch El . 0 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations N.A. vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans N.A. 1513.4 Display/exhib/special Indicate separate controls 1513.5 Exterior shut-off Schedule with type and features, indicate location Yes (a) timer w/backup Indicate location N.A. (b) photocell. Indicate location 1513.6 Inter. auto shut-off Indicate location N.A. 1513.6.1 (a) occup. sensors Schedule with type and locations N.A. 1513.6.2 (b) auto. switches Schedule with type and features (back-up, override capability) Indicate size of zone on plans 1513.7 Hotel/motel controls Indicate location of room master controls N.A. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) Yes 1514 Max. watts Indicate watts for each exit sign E1.0 LIGHTING POWER ALLOWANCE (Section 1530-1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule'with fixture types, lamps, ballasts, watts per fixture , E1.0 N.A. 1532 Exterior Lighting Summary Form Completed and attached., 'Schedule;with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) N.A. 1511 Elec motor efficiency MECH-MOT or Equipment Scheddle with hp, rpm, efficiency TRANSFORMERS (Section 1540) N.A. I 1540 'Transformers 'Indicate size and efficiency 1 I If "no" is circled for any question, provide explanation: 1 6897 REGISTERE ARCHITEC REDERICK J. GO 'IA STATE OF WASHINGTON Seo. �3 4Y • FREDERICA. GOGLIA ARCHITECT, NCARB, ISP July 18, 2013 City of Tukwila Attn: Jennifer Marshall 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Zales at Southcenter Mall 1000 Southcenter Mall, Space #C312 Project NO. 130237 Dear Ms. Marshall: RECEIVED CITY OF TUKWILA JUL 2 2 2013 PERMIT CENTER ISION N0. 1 This letter accompanies revised construction drawings for submittal as a revision to the previously approved permit drawings. The landlord review, which occurred at the same time as the permit review, necessitated the following revisions to the drawings. T1.0 - Title Sheet 1. Under Code Information, Leasable and Sales Area increases reflecting the expansion of the lease line at the storefront as required by the landlord. Occupancy Loads and Capacity of Egress were also adjusted accordingly. 2. On the Key Plan, Leasable Area was increased. 3. On the Responsibility Chart, Neutral Piers will not be part of the project. D1.0 - Demo Plan / Notes 1. Demolition at storefront expanded to encompass complete removal for expansion of lease line as required by the landlord. D2.0 - Barricade Elev / Dtls / Notes 1. Barricade height increased per landlord. 2. Graphics to be submitted as separate graphics package to mall for approval. A1.0 - Floor Plan / GC Verific. / Notes 1. Lease dimensions adjusted per landlord required expansion of lease line at storefront. 2. Storefront design revised and expanded per landlord requirements. A1.1 - Enlarged Plans / Notes 1. Storefront design revised and expanded per landlord requirements. A1.2 - Reflected Ceiling Plan / Notes 1. Storefront design revised and expanded per landlord requirements. 2. With expansion of storefront design, one additional foot of casework added. Lighting adjusted accordingly. A2.0 - Elevations 1. Storefront design revised and expanded per landlord requirements. 2. With expansion of storefront design, one additional foot of casework added. Logo placement adjusted to be centered over adjusted casework. 3. Adjusted height of window decal per landlord requirements. A3.0 - Schedules 1. B2 Rubber Base not allowed by landlord removed from schedules. 2. Corner Guards removed from project. 1950 Craig Road Suite 300 • St. Louis, MO 63146-4106 • Phone (314) 415-24 0 • ax (314) 415-2300 • • 3. Tile area calculation adjusted to reflect the expanded storefront required by the landlord. ' ; '4. Added transition detail reference per landlord requirements. A4.0 - Storefront Sections 1. Storefront section expanded to reflect landlord requirements. A5.1 - Details 1. Transition Detail re 2. ' Wood Base Detail ise1411 p r landlord requirements. e-.4per landlord requirements. A5.2 - Partition Types 1. Added partition type reflecting area of mall wall being refinished with tenant finish. F1.0 - Fixture Plan / Scheds 1. Storefront design revised and expanded per landlord requirements. 2. With expansion of storefront design, one additional foot of casework added. F2.1 - Fixture / Sign Sections / Details 1. Revised height of blade sign per landlord requirements. M1.0 - Mech. Plan / Scheds / Notes 1. Revised layout at expanded storefront per landlord requirements. M2.0 - Mechanical Details 1. Added note to RTU detail per landlord requirements. P1.0 - Plumbing Plan / Scheds / Notes 1. Revised layout at expanded storefront per landlord requirements. E1.0 - Lighting Plan / Notes / Details • 1. Revised layout at expanded storefront per landlord requirements. 2. With expansion of storefront design, one additional foot of casework added. Lighting adjusted accordingly. E1.1 - Power Plan / Notes / Details 1. Revised layout at expanded storefront per landlord requirements. 2. Added dimensions at stub ups to aid in location during construction. 3. Extended power to blade sign per keyed note 43. E1.2 - Elec Details 1. Revised wiring detail to reflect change from security case to non -security as required by tenant. E2.0 - Elec. Loads / Riser / Scheds 1. Revised load analysis and panel loads to reflect adjustments to lighting. V1.0 - Visual Merchandising Plan 1. Revised layout at expanded storefront per landlord requirements. 2. With expansion of storefront design, one additional foot of casework added. 3. Revised area calculations to reflect changes required by landlord. ,rs ' 1 '1950 Craig ;Rom Suite' 300 • St. Louis, MO 63146-4106 • Phone (314) 415-2400 • Fax (314) 415-2300 1 ^o, If you have any questions, comments or need any additional information regarding this letter please contact Jolena Shatzer at our office at anytime (800) 489-2233. Sincerely, I,/ 0:4_7 rederick J. Golia Architect, NCARB, ISP CC: File J:\Clients\Zales\ 130237\ Docs 1950 Craig Road Suite 300 • St. Louis, MO 63146-4106 • Phone (314) 415-2400 • Fax (314) 415-2300 HERMIT COORD COPY � PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0505 DATE: 07/22/13 PROJECT NAME: ZALES SITE ADDRESS: 1000 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 BEFORE Permit Issued DEPARTMENTS: �t� frP� 13 Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07/23/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 14 Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/20/13 Approved ❑ Approved with Conditions N- Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0505 DATE: 05-23-13 PROJECT NAME: ZALES SITE ADDRESS: 1000 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 49711$ OOngD isio Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05-28-13 Not Applicable Comments: Permit Center Use'On1y ate' INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route V Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-25-13 Approved ❑ Approved with Conditions EK Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only ; CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • PROJECT NAME: 1_11 L\5 PERMIT NO: ,p S 0 S SITE ADDRESS: 1000 S01Kni MK1.1rit1AMtORIGINAL ISSUE DATE: tA1k REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE STAFF INITIALS 1 o-1 122 I U , Z Summary of Revision: Received by: Summary of Revision: L, D VO 12-19 VelkIAE ara)& S Received by:, 1 j I (y Heit4r.e. S ktly REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 119 / Plan Check/Permit Number: L 1505 Response to Incomplete Letter # Response to Correction Letter # Revision # / after Pennit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: 7,,aig..5 Project Address: (-)0 , -)1j..�l--1l( p► H t Mall 1 d l 5lci Contact Person: yj/�i/ ohy !il jp 145ki Phone Number: �j/) ,3) 9 a") 9 ? 10 x Summary of Revision: / Piga CeDvii movii ire5pc, 1e-ikr Sheet Number(s): El i C(• 1 / "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: i\A," Entered in Permits Plus on H:\Applications\Foms-Applications On Line \2010 Applications \7-2010 - Revision Submittal.doc Revised: May 2011 e'rr,,Ner..elVeD Tlitelifftq JUL 22 2013 ~ERMl1 CEDER Contractors or Tradespeople Prior Friendly Page • Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name STAR ELECTRIC SERVICES INC UBI No. 602734410 Phone 4258799133 Status Active Address 14219 20Th Pl W License No. STAREES937NA Suite/Apt. License Type Electrical Contractor City Lynnwood Effective Date 8/8/2007 State WA Expiration Date 8/8/2015 Zip 98087 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status STAREE'939CZ STAR ELECTRIC Electrical Contractor General Unused 2/9/2007 2/9/2009 Expired Electrical Administrator INFORMATION License NEDZEDV942PR Name NEDZELSKIY, DMITRIY V Status Active Business Owner Information Name Role Effective Date Expiration Date NEDZELSKIY, DMITRIY V President 08/01/2007 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS l3 SURETY CO 105464623 08/05/2010 Until Cancelled $4,000.00 08/09/2010 2 DEVELOPERS SURETY 8 INDEM CO 748028C 08/08/2007 Until Cancelled 08/28/2010 $4,000.0008/13/2007 1 DEVELOPERS SURETY & INDEM CO 745446C 02/07/2007 Until Cancelled 03/24/2008 $4,000.00 08/01/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/04/2013 MARK 0 LI4TIN LAN NOTES 5IbON01-061412 KEYED NOTES: 1. RESTROOM EXHAUST FAN, EP -I, ABOVE CEILING. SWITCH AND CIRCUIT AS INDICATED. RLIMR TO MECHANICAL PLAN AND SCHEDULES FOR MORE INFORMATION. 2. ALL EMERGENCY LIGHT FIXTURES (FE, IN, X) AND NIGHT LIGHT FIXTURES 02) SHALL BE COMEGTED TO THE UNSWITGHED LEG OF CIRCUIT INDICATED. REFER TO ELECTRICAL PANEL SCHEDULE. 3. DENOTES LIGHT FIXTURE MOUNTED UNDER CABINET OR ON CEILING BELOW. REFERENCE POWER PLAN NOTES FOR J -BOX LOCATION. 4. LOCATION OF SWITCH BANK. SEE DETAIL THIS SHEET. 5. ALL ILLUMINATED STOREFRONT FEATURES INCLUDING BUT NOT LIMITED TO STOREFRONT 516NAGE, SCONCES AND ENTRY SOFFIT LIGHTS SHALL BE CIRCUITED THROUGH THE TIME CLOCK. 6. T.G.G. TO PROVIDE AND INSTALL J -BOX FOR LIGHT SCONCE. MOUNT CENTERLINE OF J -BOX AT 15° BELOW ENTRY SOFFIT LINE. REFER TO ELEVATIONS FOR HORIZONTAL PLACEMENT. GENERAL NOTES: * Intermediate or heavy duty ceiling systems (main runners members with a minimum load capacity of 12 pounds per linear foot) shall be used for support of lighting fixtures. lightingixtures weighing Tess than 56 pounds shall have 12 gage hangars attached to the grid at each fixture corner, and number 12 gunge hangars connected from the Fixture housing to the structure above. These additional wires may be slack. Fixtures weighing more than 56 pounds and pendant -hung fixtures shall be supported directly from above by approved hangars. • SMITCM SANK SI601 Ob -030211 yrs 5a 7b lc Ild I SGH-L LAMP SHtUL CEILING CEILING CEILING CEILING CASE CASE CASE CASE LIGHTS LIGHTS LIGHTS LIGHTS 13f 159 6h I2j I SGH-L LAMP SHtUL GRAPHIC / LOGO LIGHTS 6gVERA,L. AREA LIGHTS FRONT / REAR IN - CASE LIGHTS FRONT / REAR IN - CASE LIGHTS CONTRACTOR TO VERIFY EXACT CONFIGURATION REQUIRED WITH SPACE AVAILABLE. PROVIDE LABELS AS SHOWN. TOP OF SWITCH BANK SHALL NOT BE MOUNTED HIGHER THAN 48". 11 0 SEPARATE PERMIT REQUIRED FOR: echanical ❑ Electrical fumbing as Piping City of Tukwila BI.iyinlv`'';,jG DIVISION 0 ""°"--- L U I N ISCHEDUL.=042913 R I SGH-L LAMP SHtUL PLAN MARK 6 — 6H 'RAL CONTRACTOR LL - LANDLORD E - EXIS11Nb r - TENANT MNT6 TYPE FIXT QTY FlJRNISFfD 8Y TOTAL. DESCRIPTION INSTALLED BY Br PIXT I�JRND 13Y pesos' PTION LOCATION WWATTS LAti*cm Al AMERLUX: GYLR- I-34-T4GU65-E-WT-120 CL -WT OVER. SHOWCASE REG 7 T C 14 45 6E: CMH3cITNg300065 1 1 T G A2 AMERLUX, GYLR-2-34-T46Ub5-E-WT-120 GL -GL -WT OVER SHOWCASE REG 26 T G 14 40 GE: CMH34TNg30&U65 2 52 T G A3 AMERLUX: GYLR-3-3 4-T4GU65-E-WT-120 GL -GL -GL -WT OVER SHOWCASE REG 8 T G 14 135 6E: CMH3IT/U1306U65 3 24 T G B INTENSE LIGHTING: IFV642-E-IC600W-SFW GENERAL AREA REG 3 T G - 42 GE F42/TBX/841/A/EGO I 3 T G 52 INTENSE LIGHTING: IFV642-E-10600W-SFW GENERAL AREA NIGHT LIGHT REG 5 T G I 42 GE F42/1BX/841/A/EGO I 5 T G D AMERLUX: MGAV-10-T6-E-WT-I20/2T 1U-Wi^ ACCENT LIGHT OVER LOGO/GRAPHIC REG 8 T G - 11 6E: GMH1OTU/830/6I2 1 8 T G F4 HORIZON LIGHTING: TRI232SWD BACK ROOM REG 2 T G 6 64 GE, F32T8/SPX4I/ECO 2 4 T G P4E HORIZON LIGHTING, TRI232SWD-E31 BACK ROOM (EMER) REG 1 T G 4,6 64 GE: F32T8/SPX41/EGO 2 2 T G 54 LIGHTOLIER, *40832U-40872 SCONCE WALL 6 T G 8 24 SYLVANIA FT271X/841 I 6 T G 1411 MULE LIGHTING, SQ -80-11 EMER (BATT) SURF 3 T G 4,5 2 LED 11 INCL - - X TCP: 20183D EMER EXIT SURF 4 T G 3,4 4 LED - INCL - - Z 4.14111.1 IP A MO./II HORIZON LIGHTING: W7232D AO J14-R/RESTRM/OFFICE SURF 2 T G 6 b4 GE: P32T8/SPX41/EGO 2 4 T G I FIXTURE TO BE PLACED ON NIGHT LIGHT CIRCUIT. 3 MOUNT EMERGENCY LIGHTS PER LOCAL CODES. 4 BA i i r<IES INCLUDED. MINIiIJM BA 1 I ERY CAPACITY TO BE 30 MINUTE. 5 CEILING MOUNT EMERGENCY FIXTURES. T.G.G. TO PROVIDE CEILING SUPPORT AS REQUIRED. 6 LUMINAIRE SHALL BE EQUIPPED WITH AN ENERGY SAVING BALLAST. 8 FINISH, POLISHED SATIN CHROME. GLASS/SHADE, RAIN. REF. LIGHTING PLAN NOTES AND ELEVATIONS FOR JBOX AND FIXTURE LOCATION. 14 STAMPED STEEL MOUNTING FRAME WITH INTEGRAL MOUNTING BARS. 10/14/11 GENERAL NOTES * ALL LI6HT COMPONENTS, I.E. FIXTURES, BALLASTS, ETC SHIPPING TO CANADA MUST BE GSA APPROVED AND ULC LISTED. _REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. t`,' •T r ov cions will require a new plan submittal l arid may include additional plan review fees. FI COPY Permit No. is-osos Plp� rpviaw approval is subject to errors and omissions. :: S of construction documents does not authorize tr,. of any adopted code or ordinance. Receipt o� Lpproved Field . py and t ns is acknowledged: By Date: City Of Tukwila BUILDING DIVISION A2 f . I :4f • #,1 ,p3 i t, gi i I.: 1 13 .:....,.,.• ,, Z I .., •ff ...5., .........._ .............A3 __....._... 4 @o......�:�,��m .mss, s, s;s;;.e..'�� ��-NSE.�,,,.,w;»;��.�.� ss;;sn,s,�,..,..,..,......»»:Ss..,:cs;>' £3 Al is 11N t"IIYYY"Y"Y I•' ri�Vf I�ifii'�L IrU COMPLIANCE WIT • NFPA 70 -NEC JUL 2 9 NU �"'r► of Tukwila BUILDING DIVISIO L I GI-ITI NG PLAN I/4" = I'-0" LIT=0455-PLN RVISION algr E PROJECT NO.: 130231 STORE NO. 0455 SHEET: I .0 GAMERA HOUSINb QUANTITY LEGEND SI BOLOS -050 712 QUANTITY 7 4 DESCRIPTION LIGHT COLORED HOUSING DARK COLORED HOUSING DVR ELEVATION (NOT TO SCALE) TELEPHONE BOARD T.G.G. TO INSTALL I" CONDUIT FROM PHONE BOARD TO J -BOX AT BOTTOM OF 2" CONDUIT EITHER SIDE OF DVR FOR PHONE/DATA. 24 GAMERA WALL MOUNT SURFACE MOUNTED 2" CONDUIT DVR, MONITOR, AND WIRELESS RECEIVER k.,..,,, LOCATION ELECTRICAL PANEL < FACE OF WALL D 24 GAMERA PLENUM RATED WIRE ABOVE CEILING (FURNISHED AND INSTALLED BY SECURITY CONTRACTOR) FROM CAMERAS TO 2" CONDUIT DOWN TO J -BOX IN BACK ROOM. 24 GAMERA 24 24 CAMERA GAMERA PLENUM RATED WIRE ABOVE CEILING (FURNISHED AND INSTALLED BY SECURITY CONTRACTOR) FROM CAMERAS TO 2" CONDUIT DOWN TO J -BOX AT DVR IN BACK ROOM. IF LOCAL CODE REQUIRES CONDUIT ABOVE CEILING, T.G.G. SHALL BE RESPONSIBLE FOR CONDUIT INSTALLATION. IF REQUIRED, NOTIFY ZALE PROJECT MANAGER ASAP. TYPICAL GAMERA SCHEMATIC WIRING 1/4" = I' - 0" SIIOROI-102111 IP MARK O POWER PLAN NOTES KEYED NOTES: I. LOCATION OF ELECTRICAL PANEL "L". BOTTOM OF ELECTRICAL PANEL TO BE MOUNTED AT 48' A.F.F. 2. NOTES 2-3. NOT USED. 4. LOCATION OF NEW 41x4' PLYWOOD TELEPHONE BOARD ON DEMISING WALL. 5. T.G.G. TO INSTALL ONE DUPLEX RECEPTACLE AT EACH SIDE OF THE TELEPHONE BOARD FOR TELEPHONE SYSTEM AND MISCELLANEOUS EQUIPMENT. 6. NOT USED. 7. TRENCH/CHIP EXISTING SLAB FOR CONDUIT BELOW FLOOR. PLACE CONDUITS ADJACENT TO EACH OTHER AND RUN IN THE SAME WENCH ELECTRICAL CONTRACTOR TO DERATE CONDUCTOR AMPAGITY AND CONFIRM THAT CONDUCTOR INSULATION 15 COMPATIBLE WITH OPERATING VOLTAGES AS REQUIRED BY CODE. T.G.G. TO VERIFY ALL REQUIREMENTS INCLUDING SCANS AND )(RAYS WITH LANDLORD BEFORE COMMENCEMENT OF WORK. ALL PENETRATIONS TO BE SEALED WATERTIGHT. 8. DENOTES SURFACE RUN CONDUIT. q. NOT USED. 10. ELECTRICAL 511)B UP AT BRIDAL GASES TO FALL UNDER STORAGE AREA. II. NOT USED. 12. OVERHEAD GRILLE MOTOR ABOVE CEILING BY GRILLE INSTALLER FINAL ELECTRICAL CONNECTION TO MOTOR BY T.G.G. ALL OTHER GRILLE CONNECTIONS/ADJUSTMENTS I.E. EMERGENCY RELEASE, KEY SWITCHES, LIMIT SWITCHES ETC, BY GRILLE INSTALLER T G G TO ENSURE PATH OF TRAVEL FROM MOTOR TO EMERGENCY RELEASE 15 STRAIGHT AND GABLE 15 TAUT. T.G.G. TO MOUNT KEY SWITCHES AND EMERGENCY RELEASE. T.6.G. TO CONFIRM PROPER OPERATION OF GRILLE, EMERGENCY RELEASE, ETC AFTER FINAL POWER CONNECTIONS ARE MADE. 13. T.G.G. TO MOUNT KEY SWITCHES FLUSH WITH FINAL FINISH, ONE OM EACH TENANT AND MALL SIDE OF OVERHEAD GRILLE MOUNT 18' A.F.F. TO CENTERLINE. LOW VOLTAGE ELECTRICAL CONNECTION TO KEY SNITCHES BY GRILLE INSTALLER. 14. T.G.G. TO PROVIDE I" CONDUIT WITH PULL STRING, STUBBED OUT ADJACENT TO SAFE FOR ALARM WIRING. COORDINATE WITH FINAL SAFE LOCATION. 15. T.G.G. TO CONNECT MOLEX CONNECTORS FROM CASE TO CASE FOR CONNECTION OF FLUORESCENT SHOWCASE LIGHTRAILS. 16. ALL DEVICES WITH -IN SHOWCASES ARE INSTALLED BY T.F.G. AND PRE -WIRED W/ QUICK CONNECT CONNECTIONS TO J -BOX IN LEAD SHOWCASE. T.G.G. SHALL CONNECT ALL ADJACENT GASES THROUGH POWER DISTRIBUTION GABLE PROVIDED BY T.F.G. ALL SUBSEQUENT GASES SHALL BE CONNECTED IN THIS MANNER. T.G.G. 15 RESPONSIBLE FOR MAKING ALL FINAL HARDWIRE CONNECTIONS. REFER TO SHOWCASE WIRING DIAGRAM. T.G.G. RESPONSIBLE FOR CONTACTING T.F.G. TO TROUBLESHOOT LI6HTRAILS, MOTORS, LOCKS ETC. 17. T.F.G. TO INSTALL $ HARDWIRE DUPLEX RECEPTACLE AT TOE KICK, CORNER CASE, FILLERS ETC. 18. NOT USED. Iq. INSTALL, ADJACENT TO HVAC OR CONDENSER UNIT AT ROOF, HUBBELL #6080 WEATHERPROOF BOX WITH GPI #GF5262I (GROUND FAULT INTERRUPTER) RECEPTACLE WITH WEATHERPROOF COVER #GWP26GR. 20. NOT USED. 21. 6E1 REGEPTAGLE MOUNTED BELOW LAVATORY FOR POINT OF USE WATER HEATER. 5160NO2-061412 KEYED NOTES: 22. T.G.G. TO PROVIDE AND INSTALL ONE DEDICATED ISOLATED GROUND, QUAD OUTLET AT 44' A.F.F., FOR DVR/SECURITY EQUIPMENT. 23. TAG. TO PROVIDE AND INSTALL 2" CONDUIT STUBBED ABOVE CEILING WITH FLANGE FOR WIRE PROTECTION INSERTED INTO STUB UP. TERMINATE BOTTOM OF 2" CONDUIT WITH A 4" X 4" J -BOX, AT 44' A.F.F. 24. T.G.G. TO PROVIDE AND INSTALL 3-1/2" X 3-1/2" OCTAGONAL J -BOX, CENTERLINE AT 1-0' A.F.F. WITH I" CONDUIT EXTENDED TO ABOVE CEILING, FOR WALL MOUNTED SECURITY GAMERA. REFER LEGEND FOR HOUSING DOLOR COORDINATE PREWIRIN6 WITH SECURITY VENDOR BEFORE CLOSING UP THE CEILING. 25. NOT USED. 26. VOICE DOWN RECESSED SPEAKER. COORDINATE PRENIRIN6 WITH SECURITY VENDOR BEFORE CLOSING UP THE CEILING. 21. T.G.G. TO PROVIDE AND INSTALL I" CONDUIT FROM PHONE BOARD TO THE J -BOX AT THE BOTTOM OF 2' CONDUIT. 28. NOT USED. 2q. T.G.G. TO PROVIDE 3 - I" CONDUITS WITH PULL STRING FROM WORK ROOM TO MAIN POS. 5115 OUTS TO BE NO HIGHER THAN I" A.F.F. (ONE FOR POWER, ONE FOR ALARMS AND ONE FOR PHONE / DATA) AND EXTEND TO J -BOXES AT PAYCOUNTERS. T.G.G. TO LABEL CIRCUIT NUMBERS ON RECEPTACLES WITH PERMANENT MARKER. COORDINATE PREWIRING WITH SECURITY AND COMMUNICATIONS VENDOR. 30.T b.G. TO PROVIDE 3 - I" CONDUITS WITH PULL STRING FROM WORK ROOM TO REMOTE P05. 511/5 OUTS TO BE NO HIGHER THAN I" A.F.F. (ONE FOR POWER, ONE FOR ALARMS AND ONE FOR PHONE / DATA) AND EXTEND TO J -BOXES AT PAYGOUNTERS. T.G.G. TO LABEL CIRCUIT NUMBERS ON RECEPTACLES WITH PERMANENT MARKER. COORDINATE PREWIRING WITH SECURITY AND COMMUNICATIONS VENDOR. 31. NOTES 31-32. NOT USED. 33. ALL WIRING IN CEILING PLENUM (INCLUDING TELEPHONE, DATA, ALARM, AND TEMPERATURE CONTROL WIRING) SHALL BE 2. LISTED TEFLON PLENUM RATED GABLE. 34. T.G.G. TO PROVIDE 120V, I-PHASE/20 AMP SNITCH FOR SIGN, PROVIDE THREE (3) #I2 WIRING (ONE FOR HOT, ONE FOR NEUTRAL AND ONE FOR GROUND) TO EACH SIGN PER SIGN MANUFACTURER'S CRITERIA; ALL IN COMPLIANCE WITH NEG 600-6. T.G.C. TO COORDINATE LOCATION OF J-BOX(E5) TO POWER SIGN NO FART1IER THAN 5'-0" FROM SIGN. SIGN INSTALLER TO MAKE FINAL CONNECTION TO SIGN. 35. NOT USED. 36. Tb.G. TO PROVIDE TYPE WRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS. 31. NOT USED. 38. NOT USED. 31. T.G.G. TO LABEL ALL CIRCUIT NUMBERS AT ALL OUTLETS 114 BACK ROOM AND PAYGOUNTERS. 40. SHOWCASE WITH ELECTRICAL RECEPTACLE FOR Z-OSK. 41. T.G.G. TO PROVIDE I-1/2" CONDUIT WITH A LONG SWEEP AT THE BENDS WITH PULL STRING, STUBBED OUT 140 HIGHER THAN 3' A.F.F. IN SLAB FROM P05 TO SHOWCASE LOCATION FOR DATA GABLE OF SIGNATURE CAPTURE DEVICE. (EQUIPMENT TO BE FURNISHED 4 INSTALLED BY TENANT) REFERENCE DRAWINGS FOR STUB UP LOCATION. 01 4 4 REVIEWED .FOIA COMPLIANCE WITH NFPA 70 - NEC JUL 292013 Cid Tukwila BUILDING DIVISIO 40. O L -I8.20 ......_. MINOIV.IMOD. 0111111 MIMI MM. '-3 ..3/8' it »............iinr�iilii»vii.....N.........m.ii.»..Hiiii�, s1 aua.W.Wlliipillnnw.aulsii/l+'iiiAvl/M9cW.utS 0 POWER PLAN 1/4" = I' -O" PWR=0455-PLN 10 EL I3-0505 J �E PRO GT NO.: 130231 STORE NO. 0455 SHEET: El DUPLEX BOX W/ DOVER INSTALLED BY T.F.G., T.F.G. TO PROVIDE — DUPLEX RECEPTACLE WHERE INDICATED ON POWER 4 SIGNAL PLAN. BLUE CIRCUIT PREWIRED INSIDE EACH DUPLEX BOX BY TF.G LED LIGHTRAIL AT LEAD CASE 15 HARDWIRED TO POG, T.F.G. TO PROVIDE THE WHIP. PERMANENT CONNECTION TO POG 15 BY T.G.G, GAN BE COMBINED WITH "BLACK" LED CIRCUIT FROM THE SHOWCASE ELEGTROGONNEGT FLOOR MOUNTED J -BOX AT P.O.G. BY T.G.G, POWER ADAPTER GABLE PA -12 -7E -0I PREINSTALLED BY T.F.G. J -BOX BY T.F.G DUPLEX FOR PO SUPPLY PREINST BY T.F.G. MP — POWER SUPPLY FOR LED LIGHTRAIL PREINSTALLED BY T.F.G TO UT LIGHTS LIGHTS .B. J.B. PWR ❑ ❑ MOLEX CONNECTORS CASE TO CASE AT LED LIGHTRAILS DUPLEX FOR — POWER SUPPLY PREINSTALLED BY T.F.G. — POWER SUPPLY FOR LED LIGHTRAIL PREINSTALLED BY TF.G DUST DOVER 7036252 BY T.F.G. SHIPS LOOSE JB V PWR T,G.G. TO MAKE 2 CIRCUIT HARDWIRE CONNECTION TO J -BOX AT LEAD SHOWCASE - CIRGUIT I - LED POWER SUPPLY — BLAGK CIRCUIT CIRCUIT 2 - DUPLEX RECEPTACLE, BLUE CIRCUIT FRONT OF SHOWCASE JUNCTION BLOCK PJ -I2 -IO, PROVIDED BY T.F.G. SHIPS LOOSE POWER DISTRIBUTION GABLE PD -I2 -7E-06(7) PROVIDED BY T.F.G. CONNECTION TO POG BY T.G.G, FRONT OF SHOWCASE POWER CONNECTION GABLE PG -12-7E-06(7) SUPPLIED T.F.G, INSTALLED BY T.G.G, (SHIPS LOOSE) POWER CONNECTION GABLE PG -12-1E-06(7) SUPPLIED BY T.F.G. (SHIPS LOOSE) NOTE: T.G.G. SHALL CONNECT ADJACENT GASES THROUGH POWER DISTRIBUTION GABLE PROVIDED BY T.F.G. ALL SUBSEQUENT GASES SHALL BE CONNECTED IN THIS MANNER- 'TYPICAL ANNER TYPIGAL NEA SHOAGASE vVI LED AIRING DETAIL L N.T.S FLUORESCENT LIGHTRAIL AT LEAD CASE IS HARDWIRED TO POG, T.F.G. TO PROVIDE THE WHIP. PERMANENT CONNECTION TO POG 15 BY T.G.G, FLOOR MOUNTED J -BOX AT P.O.G. BY T.G.G, * PWR DUPLEX FOR POWER SUPPLY PREINSTALLED BY TF.G. t POWER DISTRIBUTION GABLE PD -12 -NE -06(7) PROVIDED BY T.F.G. CONNECTION TO POG BY T.G.G. ❑ ❑ DUPLEX BOX W/ COVER INSTAL I FP BY T.F.G., T.F.G. iYTO PROVIDE DUPLEX RECEPTACLE WHERE INDICATED ON POWER 4 SIGNAL PLAN. BLUE GIRGUIT PREWIRED INSIDE EACH DUPLEX BOX BY T.F.0 J -BOX BY TF.G POWER SUPPLY FOR LED LIGHTRAIL PREINSTALLED BY T.F.G POWER CONNECTION GABLE POWER ADAF i ER GABLE PG -12 -NE -0b0) SUPPLIED T.F.G, PA -I2 -7N -0I INSTALLED BY T.G.G. PREINSTALLED BY T.F.G. (SHIPS LOOSE) NOTE: T.G.G. SHALL CONNECT ADJACENT GASES THROUGH POWER DISTRIBUTION GABLE PROVIDED BY TEC. ALL SUBSEQUENT GASES SHALL BE CONNECTED IN THIS MANNER. TYPICAL NEA SIT DOAN SHOAGASE A/ LED/FLUOR AIRING DETA I L N.T.S 5110R05-082311 51IOR03-082311 FENT LIGHTRAIL AT LEAD CASE 15 HARDWI TO POG, T.F.G. TO PROVIDE THE WHIP. PERMANENT CONNECTION TO POG 15 BY T.G.C, POWER ADAM i EK GABLE PA -12-1E-01 PREINSTALLED BY TF.C. J -BOX BY TF.G DUPLEX FOR POWER SUPPLY PREINSTALLED T.F.G. —POWER SUPPLY FOR LED LIGHTRAIL PREINSTALLED BY TF.G DUPLEX FOR MOLEX CONNECTORS POWER SUPPLY CASE TO CASE PREINSTALLED AT FLUORESCENT BY T.F.C. LIGHTRAILS —POWER SUPPLY FOR LED LIGHTRAIL PRE INSTAU.ED BY T.F.G FLOOR MOUNTED J -BOX AT P.O.G. BY T.G.G, THIS SHOULD BE EXISTING IN STORES THAT HAVE EXISTING FLUORESCENT LIGHTRAILS. T.G.G. TO MAKE 2 CIRCUIT HARDWIRE CONNECTION TO J -BOX AT LEAD SHOWCASE. CIRCUIT I - LED POWER SUPPLY BLACK CIRCUIT CIRCUIT 2 - FLUORESGENT LIGHTRAILS. TS POWER CONNECTION GABLE PC -12-7E-060) SUPPLIED BY T.F.G. (SHIPS LOOSE) FRONT OF SHOWCASE POWER DISTRI PD -I2 -7E PROM CONNECT' POWER CONNECTION GABLE PG -12-7E-06(1) SUPPLIED T.F.G, INSTALLED BY T.G.G, (SHIPS LOOSE) NOTE: T.G.G. SHALL CONNECT ADJACENT GASES THROUGH POWER DISTRIBUTION GABLE PROVIDED BY T.F.G. ALL SUBSEQUENT GASES SHALL BE CONNECTED IN THIS MANNER. TYP I GAL RETROFIT NON SECURITY SHOAGASE A/ LED/FLUOR AIRING DETA I L N.T.S FLUORESCENT LIGHTRAIL AT LEAD CASE 15 HARDWIRED TO POG, TF.G. TO PROVIDE THE WHIP. PERMANENT CONNECTION TO POG 15 BY T.G.G, FLOOR MOUNTED J -BOX AT PAL. BY T.G.C. THIS SHOULD BE EXISTING IN STORES THAT HAVE SHOWCASES WITH EXISTING FLUORESCENT LIGHT RAILS. DUPLEX FOR POWER SUPPLY PREINSTALLED BY TF.C. POWER ADAI✓ I EK GABLE PA -I2 -7A -0I PREINSTALLED BY TF.G BY T.F.G POWER SUPPLY FOR LED LIGHTRAIL PREINSTALLED BY TF.G C4D. TYP I CAL RETROI= I T SIT DO N.T.S TE: TION GABLE -06(7) SUPPLIED T.F.G, BY T.G.C, LOOSE) T.G.G. SHALL CONNECT ADJACENT GASES THROUGH POWER DISTRIBUTION GABLE PROVIDED BY T.F.G. ALL SUBSEQUENT GASES SHALL BE CONNECTED IN THIS MANNER. SHOAGASE A/ LED/FLUOR AIRING DETAIL L 5110R04-082311 51IOR02-082311 REVIEWED PLIANCE WITH NEPA 7®- NEC JUL 292013 a. BUILDING BING DIVISION �L13-05oS E PRO ':i NO.: 130231 STORE NO. 0455 SHEET: EI.2 1/4 pL!C.TSIC4AL UIMNT S UL SI60L01-051611 E - EXISTING F - TENANT'S FIXTURE CONTRACTOR T - TENANT L - LANDLORD G - TENANT'S GENERAL CONTRACTOR 1 INSTALLED BY i SYMBOL EQUIPMENT TYPE DESCRIPTION I_ - - BELOW ELECTRICAL METALLIC TUBING SHALL BE USED WHEN CONDUIT 15 CONGEALED IN NON -MASONRY WALLS AND ABOVE DROPPED CEILINGS. ALL FITTINGS TO BE SET SCREW / LOCKNUT TYPE. G G 1 FLEXIBLE METAL CONDUIT / TUBING MAY BE USED FOR EQUIPMENT AND OUTLET BOX CONNECTIONS AS ALLOWED BY NEC.; LENGTH NOT TO EXCEED 3 1-1±1. G G 1 SURFACE MOUNTED '"'- ABOVE GL'G • o DOWN UP LIQUID TIGHT FLEXIBLE SHALL BE USED BETNEEiN VIBRATING EQUIPMENT AND OUTLET BOXES EXPOSED TO WEATHER G G 1 METALLIC CONDUIT AS ALLOWED BY N.E.G.; LENGTH NOT TO EXCEED 3 t -1± T. RIGID GALV. STEEL SHALL BE USED WHEN CONDUIT 15 TO BE EXPOSED. 0 G 1 scHEUULE 40 PVC SHALL BE USED WHEN CONDUIT 15 EMBEDDED IN OR BELOW SLAB ON GRADE. G G 1 v r�-AP /'` 1' ALARM CONDUIT CONDUIT WITH PULLWIRE ROUTED TO ALARM PANEL AT THE TELEPHONE BOARD. REFER TO THE ABOVE SPECIFICATIONS FOR CONDUIT TYPE. G 0 1 —T 11 TELEPHONE CONDUIT CONDUIT WITH PULLWIRE ROUTED TO TELEPHONE BOARD. REFER TO THE ABOVE SPECIFICATIONS FOR CONDUIT TYPE. G G I t --'-EP / 11 FUTURE USE CONDUIT CONDUIT WITH PULLWIRE ROUTED TO ELECTRICAL PANEL AND TAG FOR FUTURE U5E. REFER TO THE ABOVE SPECIFICATIONS FOR CONDUIT TYPE. 0 G 1 t ..4-12 / 1' FJTURE USE DATA CONDUIT CONDUIT WITH PULLWIRE ROUTED TO ELECTRICAL PANEL AND TAG FOR FUTURE USE. REFER TO THE ABOVE SPECIFICATIONS FOR CONDUIT TYPE. G G 1 2 aSWITCH \\-\\TH CONDUCTOR WIRE MARKS INDICATE: HOT, NBJTRAL, SWITCH AND GROUND WIRES UNLESS OTHERWISE NOTED SHALL BE RATED FOR 600V. SIZE SHALL MEET THE REQUIREMENTS OF N.E.G. OR E SIZES SHOWN ON THE DRAWINGS IF LARGER AND FOR BRANCH CIRCUITS SHALL BE N0.12 AWG MINIMUM. ALL WIRE SHALL BE SOFT DRAWN ANNEALED COPPER (q5% CONDUCTIVITY) TYPE THW OR THHN. NO ALUMINUM CONDUCTORS ARE 0 G - 4 PERMITTED NO MARKS. INDICATE TWO (3) WIRES. ALWAYS INSTALL GROUND WIRE. LEE)INDICATES SWITCH LEG CIRCUITING G G - CONTROL WIRE N0.14 AWG COPPER CONDUCTOR. 600V RATED INSULATION. G G - 20 TELEPHONE WIRE T T - 0 2 i-§ WALL JUNCTION BOX REFER TO GENERAL NOTES FOR SPECIFICATION. G G 2 FRONT/REAR INCASE LIGHTS 6 DUPLEX RECEPTACLE NEMA HEAVY DUTY 5-20R CONFIGURATION. SPEC. GRADE WITH U -SHAPED GROUNDING POLE 4 A GREEN COLORED TERMINAL FOR CONNECTION OF A BONDING JUMPER. HUBBELL OR EQUAL. G G 2 0 GEEING MOUNTED DUPLEX RECEPTACLE NEMA HEAVY DUTY 5-20R CONFIGURATION. SPEC. GRADE WITH U -SHAPED GROUNDING POLE 4 A GREEN COLORED TERMINAL FOR CONNECTION OF A BONDING JUMPER. HUBBELL OR EQUAL. G G 2 (1:1) GFl GROUND FAULT INTERRUPT RECEPTACLE GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE (GFGI) DUPLEX 20 AMP WITH NEMA 5-20R CONFIGURATION UL q43-12 CLASS A SPE -G. GRADE. G G 2 . ., . QUAD REGEPTAGLE NEMA NAVY DUTY 5-20R CONFIGURATION. SPEC. GRADE WITH U -SHAPED GROUNDING POLE 4 A GREEN COLORED TERMINAL FOR CONNECTION OF A BONDING JUMPER. HUBBELL OR EQUAL. G G 2 ® WALL TELEPHONE WALL .JUNCTION BOX WITH HUBBELL #TWJII 4 CONDUCTOR WALL PHONE OUTLET G G 2 EGR DATA WALL COMMUNICATION JACK WALL JUNCTION BOX WITH HUBBELL #26 STYLE LINE PLATE WITH #GI8 SINGLE 8 CONDUCTOR JACK G G 2 q cj 3 SNAP SWITCHES SINGLE POLE / 3 -WAY SPEC. GRADE 20 AMP 120/211 VOLTS AC RATED, GENERAL USE QUIET TYPE NEMA HEAVY DUTY WITH SCREW TERMINALS. HUBBELL OR EQUAL. G G 2 () FLOOR JUNCTION BOX HUBBELL #52531 FLOOR BOX WITH #53182 CARPET FLANGE AND *52525 DOVER PLATE. G G 2 e FLOOR RECEPTACLE HUBBELL #82531 FLOOR BOX WITH #53182 CARPET FLANGE: WITH #5362 DUPLEX RECEPTACLE WITH #53125 COVER PLATE, IF DESIGNATED TYPE "TL", WITH #4182 0 G 2 COMBINATION TWIST -LOCK AND STRAIGHT BLADE RECEPTACLE WITH #53125 DOVER PLATE. FLOOR TELEPHONE HUBBELL #62531 FLOOR BOX WITH #53182 CARPET FLANGE WITH #52125 COVER PLATE WITH 415G30gg HOUSING WITH #5530gB BLANK PLATE WITH #5530gD5 STYLE LINE PLATE WITH #0244 DOUBLE 4 CONDUCTOR JACKS G G 2 ® EGR DATA FLOOR COMMUNICATION JACK HUBBELL #82531 FLOOR BOX WITH #53182 CARPET FLANGE WITH #52125 COVER PLATE WITH #SC30gq HOUSING WITH #SS30'B BLANK PLATE WITH #55301D5 STYLE LINE PLATE WITH #018 SINGLE 8 CONDUCTOR JACK G G 2 3 SURFACE MOUNTED FLOOR JUNCTION BOX STEEL CITY GAT. #58311-3/4, 4'x2 I/8'x2 I/8" UTILITY BOX, WITH #58-G-6 COVER PLATE. G G 3 [Il 20 SURFACE MOUNTED FLOOR DUPLEX STEEL CITY CAT. #58311-3/4, 45(2 I/8'x2 I/8" UTILITY BOX, WITH l-IBBELL #5362 DUPLEX RECEPTACLE, WITH STEEL CITY CAT. #58-G-1 COVER PLATE. IF DESIGNATED TYPE "TL, USE G G 3,4 RECEPTACLE HUBBELL #4182 COMBINATION TWIST -LOCK AND STRAIGHT BLADE RECEPTACLE. [] SURFACE MOUNTED FLOOR TELEPHONE STEEL CITY CAT. #58311-3/4, 4'x2 I/8'x2 1/8" UTILITY BOX, WITH HUBBELL #0244 DOUBLE 4 CONDUCTOR JACKS, WITH STEEL CITY CAT. #58-G-16 COVER PLATE. G G 3 © 632 SURFACE MOUNTED EGR DATA FLOOR COMMUNICATION JACK STEEL CITY GAT. #58311-3/4, 4"x2 I/8'x2 1/8" UTILITY BOX, WITH HUBBELL #018 SINGLE 8 CONDUCTOR JACK, WITH STEEL CITY CAT. #58-G-16 COVER PLATE. G G 3 . FIRE RATED FLOOR JUNCTION BOX HUBBELL #PT1FPLUG.F POKE -THROUGH WITH THREE -SERVICE FURNITURE FEED AND TWO TEL/DATA TO � G G 2 O FIRE RATED FLOOR RECEPTACLE l-IUIUBBELL #Prig POKE -THROUGH WITH I -20A DUPLEX RECEPTACLE AND TELEPHONE / DATA. G G 2 TRANSt-- TRANSFORMER R MER EQUAL TO GE 600 VOLT DELTA -WYE "DRY TYPE" 3 PHASE GLASS "H" INSULATION WITH MULTIPLE TAPS ABOVE AND BELOW RATED VOLTAGE. MUST BE ENERGY STAR RATED. NA NA 5 15 GENERAL AREA LIGHTS SHALL BE GE, ITE, OR SQUARE "D" UTILIZING BOLTED BREAKERS WITH INTEGRAL MAIN E E 5 1 --......1ELECTRICAL PANELBOARD BREAKER SIZE PER PLANS. CONTRACTOR SHALL PROVIDE TYPE11 ITTEN DIRECTORY INSIDE OF PANEL DOOR. Q-1 DISCONNECT SNITCHES SHALL MEET NEMA STANDARDS FOR TYPE HD HEAVY DUTY SWITCHES AND SHALL BE GE OR SQUARE "D" MAKE. NEMA 3R ENCLOSED IF EXPOSED TO THE WEATHER, ELSEWHERE NEMA 1 GENERAL PURPOSE ENCLOSURE; HORSEPOWER RATED. G G 5 REGEpTAG1..F5 TELEPHONE PANEL BOARD TELEPHONE PANEL BOARD: 4' X 8' X 3/4" A -G PLYWOOD, PAINT TO MATCH WALL G G - i- 1V SECURITY CAMERA 11 T T - ;:: SPKR SECURITY SPEAKER 1 T T - OVERFEAD DOOR MOTOR T T - - REMARKS: I. ALL CONDUIT SHALL BE CONGEALED IN FINISHED AREAS. ALL CONDUITS TO BE LEVEL. ALL CONDUIT SHALL BE SIZED PER N.E.C, 3/4" DIA. MIN. ALL CONNECTORS, COUPLINGS AND FITTINGS PER N.E.G. REQUIREMENTS. 2. ALL COVER PLATES TO MATCH SURFACE IN WHICH IT'S APPLIED ON. 3. SURFACE MOUNT UTILITY BOX ON FLOOR. 4. PROVIDE TWO DEDICATED CIRCUITS PER DUPLEX RECEPTACLE AS REQUIRED. 5. T.6.C. SHALL VERIFY EXISTING ELECTRICAL EQUIPMENT AND UPGRADE A5 REQUIRED. GENERAL NOTES * Provide wiring devices of specification grade as Indicated and/or scheduled. Catalog numbers shown are Hubbell, unless otherwise noted. * Where the store is on any level, but the ground level, the conduit for floor outlets (including telephone floor outlets shall) be run tight against the underside of the second floor slab. Slab shall be core drilled, sleeved and sealed water tight. Locations shall be reviewed and approved by Landlord prior to any core drilling. * Where the store Is on the ground level, the conduit For floor outlets (Including telephone floor outlets shall) be run concealed in the slab. Existing slab to trenched as required to install conduits. Patch the slab reinforcement and the slab to the landlord's specifications. * Outlet boxes shall be pressed steel knockout type case iron with drilled, tapped, and plugged holes, and either hot -dipped galvanized or sherardlzed. All boxes to be of proper code size for the number of wires or conduits passing through or terminating therein. Standard size to be 4" square. * Color coding shall be In accordance with N.E.G. * All conduit, equipment, wiring, and wiring devices shall be N.E.G. rated. * Dimensions shown to wall and floor telephone outlets, yboxes, and Tight switches are to center of device. * Convenience receptacles shall be Installed at a minimum of 18" A.F.F. to centerline unless otherwise noted. * Switch devices shall be Installed at 48" A.F.F. unless noted otherwise. * All floor outlet devices shall be flush mounted with finished floor. * Existing devices that meet requirements of devices specified by construction documents In description and location shall be reused when possible. * All wiring shall be specifically approved For plenum use and be Insulated copper type THW or THWN. * The use of "BX" or "ROMEX" is not permitted. 11-0A1, A N A j. 'i S 1 I6OLO2-083111 SERVICE VOLTAGE 120/208V, 3 PHASE, 4 WIRE LOAD DESCRIPTION DEMAND LOAD (AMPS) LIGHTING (ACTUAL LOAD): 3,184 W X 1.25 s 360 EXTERIOR SIGNAGE: 2,400 W X 1.25 _ 360 RECEPTACLES. w - W 360 ** MISC. EQUIPMENT: EWH: RTHP-I: 360 1 %•. ' : 360 16,236 W 4. 360 +25% OF LARGEST MOTOR: I35q IN : 360 * Greater of cooling or heating. ** Misc. equipment Includes ecr's, Fax, security systems, grille moter, plugnolds, etc.. EXISTING 200A SERVICE (MIN. SIZE 4#3/0 GU IN 2" C.) EXISTING LANDLORD I20/208V, 34), 4 WIRE LL.'S DISTRIBUTION. VERIFY EXACT LOCATION OF MALL ELECTRIC ROOM. TOTAL: 45.1 3.8 EXIST1N6 ELIEGTRICALis "LII P 51601_05-061412 Service: 120/208 Volts 3 Phase A Wires Cabinets: SURFACE Mounted Feed: BOTTOM Fed Main: 222 Solid Neutral 200 Ampere Bus 200 Ampere Main Panel: EXISTING LOCATION CKT DESCRIPTION WATTS TYPE SIZE S ;. e : 4 R SIZE 517E WATTS DESCRIPTION KT 1, 2 1 STOREFRONT SIGN 1200 L 12 20 I 1200 i 1 20 12 SPARE 2 : I, 2 3 STOREFRONT SIGNmil 1200 L 12 20 1 r 120 12 R 1 "' AGLES IN GASES 4 2640 5 CEILING CASE LIGHTS 1110 L 12 20 1 1 20 12 L 1842 FRONT/REAR INCASE LIGHTS 6 J 3012 } T GEILI1•16 CASE LIGHTS 615 L 12 20 1 - 1215 1 20 12 R 600 ULTRASGONIG GLEANER 8 q CEILING CASE LIGHTS 1080 L 12 20 1 1 20 12 R 120 RECEPTACLES IN CASES 10 1800 11 CEILING CASE LIGHTS 615 L 12 20 1 1 20 12 L 1102 FRONT/REAR INCASE LIGHTS 12 1111 [ 13 GRAPHIC/LOGO LIGHTS 632 L 12 20 1 - qq2 1 20 12 R 360 RECEPTACLE - GFI 14 15 GENERAL AREA LIGHTS 318 L 12 20 1 1 20 12 R 120 REGEpTAG1..F5 16 1038 11 BACK ROOM LIGHTS 420 L 12 20 1 I 20 12 R 540 REFRIGERATOR 18 J q60 [ 2 Ig ENTRY LIGHTS 126 L 12 20 1 - 1326 1 20 12 M 1200 MICROWAVE 20 2 21 SCONCE LIGHTING 144 L 12 20 1 1 20 SPARE 22 144 13 23 IVR SECURITY EQUIPMENT 500 M 12 20 1 1 20 12 EWH 1800 WATER HEATER 24 1 2300 i 13 25 REMOTE EGR 250 M 12 20 1 - 150 1 20 12 M 500 TELEPHONE BOARD 26 1,3 21 REMOTE EGR 250 M 12 20 1 1 20 SPARE 28 250 1,3 2q EGR/GPU 500 M 12 20 1 1 20 SPARE 50 500 } 1,3 31 PRINTER/FAX 810 M 12 20 1 - 1810 1 20 12 M 1000 MOTORIZED O.H. GRILLE 32 1 1,3 33 REMOTE ECR 250 M 12 20 1 1 20 12 M 1000 MOTORIZED 0.H. GRILLE 34 1 1250 1,3 35 REMOTE ECR 250 M 12 20 1 1 20 SPARE 36 250 1 31 RTHP-I 5412 14 8 60 3 - 5'152 1 20 12 R 540 MUSIC EQUIPMENT 38 1 3q 5412 I 1 20 SPARE 40 5412 i 41 5412 5412 1 20 SPARE 42 - 25% LIGHTS AND SIGNS:.2,646e13305 12534 14211 L=R ANDSIGNSR SUB TOTALS I-OA`DTYPELEGEND'25% CEP LARGEST MOTOR:A = RECEPTACLE DEMAND LOAD: CONNECTED LOAD: 40,050 1 M = MISCELLANEOUS DEMAND AMPERES: 122.4 PHASE BALANCE: 5.4% 14 = HVAC WH = WATER HEATER REMARKS: General Notes: 1. PROVIDE AND INSTALL LOCK -ON BREAKER. 2. CIRCUIT TO BE CONTROLLED THROUGH THE TIMEGLOCK. 3. PROVIDE ISOLATED, INSULATED GROUND TO BUILDING COPPER OR STEEL. REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT. 4. PROVIDE DEDICATED CIRCUIT. 5. NEW CIRCUIT AND BREAKER BY T.G.G. * All Items grayed out are existing to remain. * All breakers to be heavy-duty, bolt -on switching type. * coordinate stub -ups with safe locations. * Minimum AIG: 14,000. * T.G.G. to furnish type written Identification directory card for all main and branch circuits. * Electrical contractor shall balance panel Toads to within 10% of each phase. 208V 3P/60A NON-FUSED DISCONNECT AT RTHP-1, PROVIDED BY T.G.G. T.G.G. TO PROVIDE 6OA FEEDERS (MIN. SIZE 3 #6, 1 #I0 I.G., 1" C.) T.G.G. TO PROVIDE 20A FEEDERS (MIN. SIZE 3 #12, 1/2" G,) J L.L.'S SPLICE BOX (VERIFY LOCATION IN FIELD). EXISTING METER EXISTING 200AS - LANDLORDS SPACE I TIME CLOCK - 24-HOUR TYPE, BY EXISTING 200A FEEDERS FROM LL.'S SPLICE BOX TENANT'S SPACE - 0 EXISTING PANE.. L 208v, 34 L -I4 RTHP-I ROOF 11P/6FI RECEPTACLE PROVIDED WITH UNIT CEILING RECEPTACLES FOR BURGLAR ALARM AND TELEPHONE REQUIREMENTS LOCATED ADJACENT TO TELEPHONE BOARD ELECTRICAL RISER DI ARAM NO SCALE 5160R01-050212 REVIEWED .FOR LIANCE WITH NFPA 70 NEC JUL 292013 ity 1'ukcwila BUILDING DIVISION NOTES: I. T.G.G. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING ELECTRICAL EQUIPMENT TO BE REUSED 15 OF ADEQUATE SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. IF DISCREPANCIES ARISE CONTACT ZALE PROJECT MANAGER. 2. NOT USED. 3. ALL WIRE SHALL BE COPPER ONLY, THW, THWN, THHW, OR APPROVED EQUAL OR BETTER. ALL WIRING SHALL BE IN CONDUIT. 4. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, LIGHTS, DEVICES, CONDUIT, WIRE, ETG) NOT BEING USED SHALL BE REMOVED FROM THE SITE. DO NOT ABANDON IN PLAGE. E�13-0565 J 1 Q:9 E PROJ .0 1 m m H tn 111 Q V STORE NO. 0455 SHEET: X2.0