HomeMy WebLinkAboutPermit EL13-0522 - YANKEE CANDLE - TENANT IMPROVEMENTYANKEE CANDLE 630 SOUTHCENTER MALL EL1 3-0522 City ottukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 9202470010 Address: 630 SOUTHCENTER MALL TUKW Project Name: YANKEE CANDLE ELECTRICAL PERMIT Permit Number: EL13-0522 Issue Date: 07/31/2013 Permit Expires On: 01/27/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: LAUREN CHASE Address: 16 YANKEE CANDLE WY , S DEERFIELD MA, 01373 Contractor: Name: ABACUS ELECTRIC CO Address: 9804 SALES RD S STE A-1 , LAKEWOOD WA 98499 Contractor License No: ABACUEC928LT Phone: 410-544-1700 Phone: 253 984-1611 Expiration Date: 06/30/2014 DESCRIPTION OF WORK: ELECTRICAL FOR TENANT IMPROVEMENT Value of Electrical: NRES: $13,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: UNKNOWN National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $395.13 2008 Date: -7-7 1- 13 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: / Print Name: /(C/Vi ik Lar i L This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL13-0522 Printed: 07-31-2013 • • PERMIT CONDITIONS Permit No. EL13-0522 **ELECTRICAL** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL13-0522 Printed: 07-31-2013 1 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi IaW A. gov Electrical Permit No. 1 L-13 0 5) Project No. �-3UII-'�13 Date Application Expires: \\ (For office use only) Date Application Accepted: ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 630 SOUTHCENTER MALL Suite Number: 204 Floor: 2ND YANKEE CANDLE Tenant Name: PROPERTY OWNER Name: LAUREN CHASE YANKEE CANDLE Name: WESTFIELD SOUTH CENTER City: S DEERFIELD State: MA Zip: 01373 Address: 633 SOUTHCENTER MALL Email: lauren_chase@nationalpermits.com City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: LAUREN CHASE YANKEE CANDLE Address: 16 YANKEE CANDLE WAY City: S DEERFIELD State: MA Zip: 01373 Phone: (410) 544-1700 Fax: (410) 544-1692 Email: lauren_chase@nationalpermits.com New Tenant: ® Yes ❑..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): /3 oro >H " g1L/, 456re Pc4746 Will service be altered? ❑ Yes Q No Adding more than 50 amps? Type of Use: Mercantile (Retail) - General Power and Lighting Type of work: ❑ New 0 Addition 0 Service Change ❑ Low Voltage 0 Generator 0 Fire Alarm Property Served by: m Puget Sound Energy 0 Seattle City Light H:Wpplic tions\Forms-Applications On Line \2011 Applications'Electrical Permit Application Revised 8-9-11.docx Revised: August 2011 bh O Yes 0 No ❑ Remodel O Telecommunication VI Tenant Improvement ❑ Temporary Service Page 1 of 2 • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY C • ' IF ` THAT VE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY ' PERJUR THE ' AWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUIL 1.1►G OWN ' .� R ELE RICAL CONTRACTOR: Prin ' ame: Walk. N 09-m C,cs Mailing Address: Day Telephone: /�,/ Z� Z° I� Date:' 1 V" s— /T en) CIJbCJ Ay H:'Applic ions\Forms-Applic 'ons On Line \-• I h tions�Electrical P�mit �jppli tion Revise -91 Tex ,/ A st _01 I /,/ a� /�,// / bh V`✓1 � _ !/ IVVJ LL III City State Zip Page 2 of 2 • • CCity of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.ov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0522 Address: 630 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/30/2013 Applicant: YANKEE CANDLE Issue Date: Receipt No.: R13-02257 Payment Amount: $316.10 Initials: WER Payment Date: 07/31/2013 03:24 PM User ID: 1655 Balance: $0.00 Payee: KEVIN ULRICH TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 025337 ACCOUNT ITEM LIST: Description 316.10 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 316.10 Total: $316.10 ...,..• oo..ei.,t_na Printed: 07-31-2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0522 Address: 630 SOUTHCENTER MALL T JKW Status: PENDING Suite No: Applied Date: 05/30/2013 Applicant: YANKEE CANDLE Issue Date: Receipt No.: R13-01759 Payment Amount: $79.03 Initials: WER Payment Date: 05/30/2013 10:25 AM User ID: 1655 Balance: $316.10 Payee: NATIONAL SERVICES GROUP TRANSACTION LIST: Type Method Descriptio Amount Payment Check 334041 79.03 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 79.03 Total: $79.03 Printarl• nc_1n_7n1A INSPECTION RECORD (� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 367 Permit Inspection Request Line (206) 431-2451 Project: 0.6.� v1/ Type of Inspection: /�? `toV - Address:30 Date Called: Special Instructions: Date Wanted: ?D(p a. Requester: Phone No: ii)Approved per applicable codes. Corrections required prior to approval. r, /COMMENTS: D I Inspector: Date: °4 3 REINSPECTION FEE REQUI ED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. IrERMIT NO. CITY OF TUKWILA BUILDING DIVISION L (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 Project:. Ad.) OvibitzType of Inspection: 2400 3-1Q + o trJDcckr( u (03'0 Address: 63,0 /I vv Date Called: r ecoi lt t JrA,.\Jatc14 odic: Special Instructions: Date Wanted: ©� p.m. Requester: Phone No: LJApproved per applicable codes. EI Corrections required prior to approval. COMMENTS: _ gqsni� -no koA ILA, m gr5"/ y J�-T1 kolQ A i 4 ooP pal P l — 13fic4 teorl 0 uti b -bd LoCAV CIRCJIr 3-1Q + o trJDcckr( u (03'0 — SA f-tpak.. 1.1 i. -1 -4.1x04 -4A, �Qa,u t 2( 1 I Dc.t. Ch - P 1 - - AL& J rte& Oaf •0 LJdoJ rill, s if r ecoi lt t JrA,.\Jatc14 odic: In Date: v7/05713 REINSPECTION FEE REQUIRE Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit (u3--os2z, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 I---.„ (206) 431-3670 Permit Inspection Request Line (206) 431-245.1 Project: , ordbtoe Type of Inspection: Type 160 3 Address: / rA14/ Date Special Instructions: Date Wanted: 3Q a.m p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. / COMMENTS: CEtNA)cl CoJt-e %go P Inspector: Date: ar 3„, (5 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tz, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ! IC l 64S)1,6 `( Type of Inspection: 7®O ? / Address: D H Date Called: Special Instructions: Date Wanted: l .m. Requester: Phone No: LJApproved per applicable codes. r, Corrections required prior to approval. COMMENTS: (?A fin -�- (A)Md,5 , 4,„,,UDS A4, Inspector: Date: 6 /3 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. 5 .4 'Jt' INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. 1NA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:(( Type of Inspection: Address: 'o _se 1441 c- Date Called: Speciailn_structions: 1°//‘ Date Wanted:L/ 43 ' a.m. m. Reques'fer: Phone No: 'Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ,1(47 DIV s 7-- 57166 /)r' Aon l 1 J /y7WAC ? ?,<_ L �fSCJr✓»ctai� o ��/EV (22,,774c: 72' \2v— Inspector: rn2y : 5 13-nrkiay Date. y/V O n REINSP(CTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2009 Washington State I gv Code Compliance Form for Nonresidential a ultifamily Residential Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address Yankee Candle Date 5/14/2013 The following information is in the 2009 Washington State necessary to check a Nonresidential Erie permit application for compliance with the lighting, motor, and transformer requirements gy Code. Applicability (yes, no, n.a.) Code Section Component Information Requirec Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control/access Schedule with type, indicate locations E.1 Yes 1513.2 Area controls Maximum limit per switch E.2 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans Yes 1513.4 Display/exhib/special Indicate separate controls E. 2 N.A. 1513.5 Exterior shut-off Schedule with type and features, indicate location (a) timer w/backup Indicate location „. �^�' "Le (b) photocell. Indicate location ��- � n art 1513.6 Inter. auto shut-off Indicate location • 1513.6.1 (a) occup. sensors Schedule with type and locations Yes 1513.6.2 (b) auto. switches Schedule with type and features (back-up, override capability); Indicate size of zone on plans E.2 1513.7 Hotel/motel controls Indicate location of room master controls 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) Yes 1514 Max. watts Indicate watts for each exit sign E.2 LIGHTING POWER ALLOWANCE (Section 1530-1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) Yea 1511 Elec motor efficiency MECH-MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) N.A. 1540 (Transformers 'Indicate size and efficiency 1 l If "no" is circled for any question, provide explanation: REVIEWED I -Oh COMPLIANCE WITH NFPA70-NEC JUN 0 5 2013 City of Tukwila BUILDING DIVISION EL3O5Z2 9269 5 13 JIWAY L. PO" cRS STATE OF W 'H!NGTON RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER 2009 Washington State gy Code Compliance Form for Nonresidential aillultifamily Residential Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address Yankee Candle Date 5/14/2013 Westfield South Center For Building Department Use Seattle, WA Applicant Name: Yankee Candle Co., Dave Conway ApplicantAddress: 16 Yankee Candle Way Applicant Phone: South Deerfield, MA 01373 Project Description Merch Display • New Building • Addition Alteration t: Plans Induded Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive 1 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 12 not changed • No changes are being made to the lighting and space use ■ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft ** ,ross rrrtenor Area in ft, Allowed x Area 101 & 102 Retail 1.33 1647 2191 Merch Display Sales 0.60 1060 636 G LED Downlight 12 17 204 ** From Table 15-1 (over) - document at exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 2827 Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed A LED Track Head 88 17 1496 01 LED Track Head 16 17 272 G LED Downlight 12 17 204 L Fluorescent Strip 7 64 448 FL Light/Fan 1 100 100 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2520 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2009 Washington Strlergy Code Compliance Forms for Nonresidential and family Residential Mechanical Permit Plans Checklist MECH-CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address Yankee Candle Date The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Ene gy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Pians Building Department Notes HVAC REQUIREMENTS (Sections 1401-1424) 1411 Equipment Performance Yes 1411.1 Minimum efficient ytype, Equipment schedule with capacity, efficiency M. 1 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss N.A. 1411.1 Air-cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water-cooled chiller Full -load and NPLV values adjusted for any non-standard conditions Yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule M. 1 N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls Yea 1412.1 Temperature zones Indicate locations on plans M.1 Yes 1412.2 Deadband control Indicate 5 degree deadband minimum M.1 N.A. 1412.3 Humidity control Indicate humidistat Yes 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback M.4 N.A. 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control Yee 1412.7 Balancing Indicate balancing features on plans 14.3 N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high -occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. Yee 1423 Thermostat interlock Indicate thermostat interlock on plans M.4 Yes 1432.2.1 Temperature Reset Indicate temperature reset method M.4 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M.1 N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N. A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems Yes 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements M.3 Yes 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested m.3 N.A. 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans Yes 1414.2 Duct insulation Indicate R -value of insulation on duct M.3 1415 Piping Systems N.A. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements M. 3 Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. M.3 Yes 1416.3.4 Documentation Indicate O&M manuals, record drawings, staff training M.3 Yes 1416.3.5 Comm. Report Indicate requirements for final commissioning report M.3 Yes 1416.4 Compliance Chklist __Submit to building official upon substantial completion. M.3 Yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer M.1 2009 Washington Stenergy Code Compliance Forms for Nonresidential andlikfamily Residential Mechanical Permit Plans Checklist Continued MECH-CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address Yankee Candle Date The following 'nformation is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R-10 insulation under tank N.A. 1442 Shut-off controls Indicate automatic shut-off of circulators or heat trace N.A. 1443 Pipe Insulation Indicate R -value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R-12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460-1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401-1424 or 1440-1465 , provide explanation: 2009 Washington Stateergy Code Compliance Forms for Nonresidential multifamily Residential Mechanical Summary MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Info Project Address Yankee Candle Date Westfield South For Building Dept. Use Seattle, WA Applicant Name: Yankee Candle Co. - Dave Conway Applicant Address: 16 Yankee Candle Way Applicant Phone: South Deerfield, MA01373 Project Briefly describe system type Description mechanical and features. Plans Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 ti Indudes Compliance Option 0 Simple System Q Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity2 Btu/h. OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU -1 RTU Carrier 50HC-A06A2M5-0A1F0 60 Econ. 13 N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N RTU -1 Elec. Carrier with RTU 27 Econ 37 N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SP1 HP/BHP Flow Controls Location of Service 11f available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from 2009 Washington State Ogy Code Compliance Forms for Nonresidential multifamily Residential Mechanical Summary (back) MECH-SUM 2009 Washington State Energy Code Comp lance Forms for Nonresidential and Multifamily Residential Revised February 2011 System Description See Section 1421 for full description p of Simple System qualifications. All Systems: t: No humidification? t. No Reheat? tf Heating/Cooling or Cooling Only:? P: Constant vol? • Split system? ■ <=84,000 Btuh? t. Economizer included? t: Air cooled. ti Packaged sys. • <=135,000 Btuh. Cooling Cap <=15 Btuh/ft2? • • Heating Cap. > 0 & <=10 Btuh/ft2 If Heating Only: • <1000 cfm? • <30% outside air? ■ Heating Cap. <=10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Reference Section 1421 , alifies Economizer Exception tion 1 Simple System Allowed (section 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH-COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. • • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0522 DATE: 05-30-13 PROJECT NAME: YANKEE CANDLE SITE ADDRESS: 630 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued D PARTMENTS: Bui ing ivision •l� Fire Prevention n Planning Division Public Works ❑ Structural n Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 06-04-13 Not Applicable Comments: Pen►iirCenter Use Only . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route 14 Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07-02-13 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Pri r Friendly Page Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company ABACUS ELECTRIC CO 2539841611 Po Box 1030 Milton WA 98354 Pierce Limited Liability Company ABACO CONTRACTORS LLC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602838703 Active ABACUEC928LT Electrical Contractor 6/30/2008 6/30/2014 General Unused Electrical Administrator INFORMATION License GROSSBJ922JG Name GROSS, BRYAN J Status Active Business Owner Information Name Role Effective Date Expiration Date MOSS, HAYWOOD TROY Partner/Member 06/30/2008 Bond Amount SMITH, SHANE Partner/Member 06/30/2008 9807640 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Lexon Ins Co 9807640 06/27/2011 Until Cancelled $4,000.00 06/01/2011 1 COLONIAL AM CAS & SURETY OF MARYLAND LPM4076005 06/27/2008 Until Cancelled 06/27/2011 $4,000.00 06/30/2008 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information No records found for the previous 6 year period httnsJ/fortress.wa.gov/lni/bbin/Print.asnx 07/31/2013 91'4p" - LEASE DIMENSION II1-0II 24'-O" 24'-0" 24'-0" 8'_6" 18'-0" ADJACENT TENANT 20'-O" „„„„ .„„.7 „:„ f 1 1 I - .1 y 8' _3 20'-10 1/2" 11,7 (1 �i 1111'.1"1-1 1111:1 10- 7" 1 9 33 1 AFF '�' ' 1 LEASE 0IMENSION TYP. FOR 4 A -I5 1 6G TO PROVIDE NEW PUSH BUTTON TO BE CONVECTED TO BUZZER AT STOCK/SALES NALL 15" AFF zor A-35/31/34 r NEN BUZZER TO BE CONNECTED TO NEV( PUSH BUTTON AT SERVICE DOOR 1 EXIT CORRIDOR 12" 2'-10" I' -I 1'1 A-5 EXTEND F.T. PLYWOOD BACKER BD. AS REQ'D. FOR NEW PANEL EXIT Power Plan SCALE: 1 /4" =1'-0" A -I1 LAN: DI -D4) -1'-8" A -I A-3 1 113 rtl it !il 1 1 I a J ii // !ilii!!! ilii !!ilii! !il,,,�i�i� ADJACENT TENANT 16'-0" 14'710 1/2" - _..-- - ,,._�__.._....._..._.. ..._._....._.. _...._I__.._._._._._ ............... _ _ _ ' O 111 .r.J..I I , 11 ,II I I I ;,, I I i 18 L(41. 11 i1 l AFF 111 1 I I tit AFF � N Ar ° 0 I' 2' 4' 8' EP RA�� E PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION EXIT/EMERGENCY LIGHTING NOTE: THE GENERAL CONTRACTOR SHALL TEST AND VERIFY IN FIELD IF THE EXISTING EXIT AND EMERGENCY LIGHTING GAN BE REUSED. IF NOT, CONTACT YANKEE CANDLE COMPANY PROJECT MANAGER. FIRE ALARM NOTE: GENERAL CONTRACTOR MUST USE L/L'S APPROVED CONTRACTOR FOR THE FIRE ALARM DESIGN, PERMITTING, AND INSTALLATION. DEMOLITION NOTE: THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR THE REMOVAL OF ALL ELECTRICAL DEVICES, EQUIPMENT, ASSOCIATED CONDUIT/WIRE, ETG. NOT BEING REUSED. DO NOT ABANDON IN PLAGE. REFER TO ARGHITEGIURAL D.I DEMOLITION PLAN. ---ADJACENT TENANT LOW VOLTAGE NOTES: I. THE GENERAL CONTRACTOR SHALL PROVIDE AM-iKOPRIATE CONDUIT FOR ALL LOW VOLTAGE WIRING A5 REQUIRED BY ALL LOCAL GOVERNING CODES. IT 15 THE SOLE RESPONSIBILITY OF THE G.G. TO VERIFY LOCAL CODE REQUIREMENTS AND COMPLY A5 REQUIRED. 2. THE GENERAL GONTRAGTOR 15 RESPONSIBLE FOR ACQUIRING. LOW VOLTAGE PERMIT A5 REQUIRED BY APPLICABLE LOCAL GOVERNING MUNICIPAL AGENCIES. 3. ALL LOW VOLTAGE WIRE RUNS TO BE CONTINUOUS, NO SPLICING ALLOWED. IMPORTANT NOTE: REFER TO ARCHITECTURAL A.4 REFLECTED CEILING PLAN FOR DIMENSIONS ilii f //ilii fiiii ///ilii .�!/ilii/ f fiiii%/!ilii /ilii!/!ilii / /!iii! fiiii! f/ilii AZT"' f lfiiii/ 7//i f /ilii .�/iii!/ //.�/!/iio���i/ilii /fS:SZ%ff::: eff.g"":S/lJ��:S� 0.,;Z/.ii�iS�L:7;":i1O1/:" Z.J�i�!!o�/f/ffffi�iif�!/!!/JJfff„"ff!flJJi�//!fes/�jffO�i�1�/!fZf ". /" 1M".".:11"/f//1/!//fllOO.�i`/llAZT"/IO�G�/iffJi�.�f//r////i01i'55"5.7d,"„ c- /!//.r 41 A-2 I A-8 RI CORRIDOR xV- I E1 A -I2 E1 A-6 X1 Nom !////fff !f//./!!! Lighting Plan SCALE: 1/4" = 1'-0" now INTERIORS vo A liii ."!hilfi/"."...ffi�i## ## 2-#"/ i`iii141#"l##5 iii�! i„iiMf"/..%%,o,if%,l1/i!,i,li7%l .#47/»AS-A,rmofloiM !i""is ADJACENT TENANT O I' 2' 4' 8' Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 • 1946 F. 860 • 678 • 7111 nidesign@nidesign.net © 2013 CONSULTANTS Project Management * Design REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. DR':rl^ A kali G index; date: 5.6.13 5.1.13 5.10.13 12035 COLWICK SAN ANTONIO, TX 78216 ISSUED TO CLIENT FOR FINAL REVIEW ISSUED TO LANDLORD FOR FINAL REVIEW ISSUED FOR BID, 4 PERMIT 'Frt. I:..:IIN.::..: 5. 10. 13 Electrical Plans Lc!ITclg RI NEVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC JUN 0 5 2013 City of. iia. BUILDING i ISION SCONCE LIGHT FIXTURE, CENTER SCONCE AT 1'-6" A.F.F. ON FADE OF MILLWORK COLUMN (TYP. OF 2) FILE COPY Permit No.27'<)59---Z2. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and isadmowiedged: AS NOTED By Date City Ofa BUILDING DIVISION 0 SHEET NOTES I. NEN SALES AREA TRACK LIGHTING SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E,2. 2. NEW SALES AREA LIGHTING SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 3. STOREFRONT LIGHTING FIXTURES SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EM5", SEE DETAIL I ON SHEET E.2. 4. STOREFRONT SIGN GIRGUIT(5) SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 5. POWER FOR SIGN TO BE LOCATED ABOVE CEILING, COORDINATE FEED TO STOREFRONT WITH SIGN CONTRACTOR. ELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION TO SIGN. 6. PROVIDE NEW WALL MOUNTED OCCUPANCY SENSOR SWITCH MODEL #WSD IN/ MANUAL OVERRIDE SWITCH FOR STOCKROOM LIGHTING. REFER TO MANUFACTURER'S SPECIFICATIONS FOR FURTHER INFORMATION. 1. REMOVE EXISTING, PROVIDE NEV( WALL MOUNTED OCCUPANCY SENSOR SWITCH MODEL # NW FOR TOILET LIGHT/FAN FIXTURE. REFER TO MANUFACTURER'S SPEGIFIGATIONS FOR FURTHER INFORMATION. REFER TO DETAIL I/E.I 8. NIGHT LIGHTING, EXIT SIGNS AND EMERGENCY EGRESS LIGHT FIXTURES SHALL BE CONNECTED TO CIRCUIT BREAKER(5) WITH LOCK -ON DEVICES, LOCKED IN THE "ON" POSITION. WIRE NEW WITH EXISTING. q. TRACK LIGHTING SHALL BE PROVIDED WITH CURRENT LIMITING DEVICES IN THE WATTAGES AS INDICA I ED ON THE DRAWINGS TO MEET (ECG REQUIREMENTS FOR ENERGY CONSUMPTION ASSOCIATED WITH LIGHTING. WIRE THROUGH LIGHTING CONTROL PANEL "EMS", REFER TO DETAIL I/E.2 10. SPEAKERS AND SPEAKER WIRE SHALL BE PROVIDED AND INSTALLED BY YGG VENDOR. II. PROVIDE QUAD OUTLET, STORE PHONE (VI) AND LAN DI TO SERVER. TELEPHONE AND DATA SHALL BE IN A COMMON DEVICE BOX. SEE DETAIL 6/A.5. 12. ELECTRICAL CONTRACTOR SHALL INSTALL (2) DUPLEX RECEPTACLES AND TELEPHONE/DATA JACKS MOUNTED ® 8" A.F.F. TO SERVE GASHWRAP EQUIPMENT. TELEPHONE/DATA SHALL BE COMBINED IN THE SAME BOX. MILLWORK TO BE MODIFIED FOR ACCESS IN THE SIDE FOR CONNECTION OF EQUIPMENT TO RECEPTACLES AND TELEPHONE/DATA JACKS. PROVIDE (2) 3/4" CONDUITS TO PHONEBOARD FOR TELEPHONE/DATA CABLING. ELECTRICAL CONTRACTOR TO RUN (3) GAT 5 LINES WITHIN CONDUITS BACK TO SECURITY CLOSET AND TERMINATE IN LINKSYS ROUTER. 13. ELECTRICAL DISTRIBUTION EQUIPMENT 15 EXISTING AND SHALL BE REUSED / RELOCATED. TO REMAIN. MODIFY A5 REQ'D. 14. LIGHTING CONTROL PANEL "EM5" 15 NEW, FURNISHED BY YGG VENDOR, INSTALLED BY TENANT'S ELECTRICAL CONTRACTOR. SEE DETAIL 1 ON 51 ICET E.2 FOR ADDITIONAL INFORMATION ASSOCIATED WITH THE LIGHTING CONTROL PANEL. 15. SECURITY SHELVING INSTALLED BY GENERAL CONTRACTOR. DEVICES INCLUDING POWER OUTLETS, LAN DI -D4 QUAD DATA JACK TERMINAL, AND A DUPLEX TELEPHONE JACK (VI AND V3) PER DETAIL 2 ON SHEET E.2. PROVIDE FIRE RATED BACKBOARD FOR MOUNTING OF SECURITY, LAN, SPEAKER, AND POWER EQUIPMENT. 16. MOUNT RECEPTACLES LOCATED ABOVE HUTCHES HORIZONTALLY AT 8'-8" AFF 50 THAT IT 15 NOT VISIBLE FROM THE SALES FLOOR. SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 11. SECURITY SYSTEM DEVICES, CAMERAS, AND MONITORS ARE SUPPLIED BY TENANT. ELECTRICAL CONTRACTOR SHALL INSTALL I" CONDUIT TO SEGURITY SHELVING FOR EACH DEVICE. COORDINATE EXACT LOCATION WITH YCC PROJECT MANAGER PRIOR TO INSTALLATION. 18. PROVIDE POWER FOR NEW UNDER -COUNTER INSTANTEOUS ELECTRIC WATER HEA 11_K la. PROVIDE NEW ELECTRICAL CONNECTION AND CIRCUITRY FOR ROOF TOP UNIT - 208 VOLT, 3 PHASE, ????A. ELECTRICAL CIRCUITRY SHALL CONSIST OF (3) #??? CU. 20. PROVIDE NEW CIRCUITRY FOR DUPLEX RECEPTACLE AT ROOF TOP UNIT FOR SERVICING OF EQUIPMENT. 21. CEILING SMOKE DETECTOR 15 NEW AND SHALL BE WIRED WITH AND COMPATIBLE WITH FIRE ALARM SYSTEM. 22. FIRE ALARM NOTIFICATION DEVICE 15 NEN AND SHALL BE WIRED WITH AND COMPATIBLE WITH MALL FIRE ALARM SYSTEM BY MALL REQUIRED MALL FIRE ALARM CONTRACTOR. RECEIVED CITY OF TUKWILA MAY 302013 PERMIT CENTER L13' O5Z2 CURRENT LIMITER SPECIFICATIONS NUMBER OF TRACK HEADS PER CIRCUIT DETERMINES SIZE OF CURRENT LIMITER. GALGS BASED ON 16W PER TRACK HEAD. EQUATION: GLD SIZE = # TRACK # TRACK HEADS I-5 6-14 15-2q 30-44 45-5q 60-11 HEADS x FIXTURE WATTS x 1.25 CLD PART # MAX WATTS MAX AMPS REGI -W" 120 RE63-1A1 300 25 REG6-W 600 5 REGq-W qoo 15 REG 1044 1200 10 REGI2-11 14.40 12 COPROJ #': #204 L #644 Westfield South Center Seattle, WA ,,,r.,w 1 47 ft.: 6 ::.J:: r 13064 1 E.1 CONTRACTOR TO REMOVE SWITCH COVER AND REPLACE AFTER ADJUSTING SENSOR SETTINGS TO CENTER POSITION A5 SHONN. OCCUPANCY SENSOR SCALE: NO SCALE JIMMY L. POWERS STATE OF WASHINGTON E.1 GENERAL POWER & LIGHTING NOTES A. UNLESS NOTED OTHERWISE, ALL LIGHT SWITCHES ARE 48" AFF. B. UNLESS NOTED OTHERWISE, ALL HEIGHTS ARE TO CENTER OF DEVICE. G. ALL STEREO EQUIPMENT FURNISHED BY THE TENANT AND INSTALLED BYTENANT'S CONTRACTOR IN SECURITY SHELVING AND IN THE CEILING. D. PROVIDE 3/4" CONDUIT WITH PULL WIRE FROM EACH THERMOSTAT, TELEPHONE, LAN OR SECURITY DEVICE BACK TO THE SECURITY SHELVING. PROVIDE BUSHING ON THE END OF ALL CONDUIT. E. ALL LAN (DATA) OUTLETS AND TELEPHONE OUTLETS SHALL BE CLEARLY IDENTIFIED AS SUCH, I.E. "VI", "DI", ETG. F. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT AND WIRE REQUIRED TO MAINTAIN CONNECTIONS TO THE MALL MANAGEMENT CONTROL SYSTEM(5). FIELD VERIFY REQUIREMENTS WITH TENANT COORDINATOR PRIOR TO CONSTRUCTION. G ELECTRICAL CONTRACTOR SHALL RUN ALL TENANT PROVIDE LAN CATEGORY 5E COMPUTER WIRING, JACKS AND PROVIDE FINAL CONNECTIONS. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR CONDUIT AND JUNCTION BOXES A5 REQUIRED. H. ALL UNUSED ELECTRICAL CONDUIT AND WIRING SHALL BE REMOVED AND DISPOSED OF. THIS SHALL INCLUDE ALL HANGING AND SUPPORT MATERIAL A5 WELL. I. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL ELECTRICAL AND LOW VOLTAGE PERMITS. EMS PANEL ------- LSX 12 C------- RED 12 C------ T- WHT 12 ------- GI -ID 12 120V POWER -�- 120V POWER 120V POWER POWER CONNECTIONS EARTH GROUND a ALL LIGHTING FIXTURES AND OCCUPANCY SENSOR SWITCHES ARE FURNISHED BY TENANT THRU CAPITOL LIGHT. K. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED EQUIPMENT DISCONNECT SWITCHES FOR HVAC, PLUMBING, ETC. EQUIPMENT. L. SALES FLOOR LIGHTING, STOREFRONT LIGHTING AND SIGN LIGHTING SHALL BE CONTROLLED BY LIGHTING CONTROL PANEL "EMS". SEE DETAIL I ON SHEET E.2. M. LIGHT FIXTURES LABELED "NTE" SHALL BE NIGHT LIGHTS. N. LIGHT FIXTURES, DEVICES, ETG. LABELED "EX" ARE EXISTING TO REMAIN. 0. LIGHT FIXTURES, DEVICES, ETG. LABELED "EX/R" ARE EXISTING TO BE RELOCATED A5 INDICATED. P. ALL EXIT, EMERGENCY, AND NIGHT LIGHT FIXTURES SHALL BE GONNEG I I_ ' AHEAD OF ANY SWITCHING OR CONTROLS. Q. THE TENANT'S ELECTRICAL CONTRACTOR SHALL INCLUDE ALL COSTS ASSOCIATED WITH THE LANDLORD'S FIRE ALARM SYSTEM AS REQUIRED. THE TENANT'S ELECTRICAL GONTRAGTOR SHALL INCLUDE ALL COSTS ASSOCIATED WITH FIRE ALARM DRAWINGS, PERMITS, EQUIPMENT PURCHASE AND SYSTEM PROGRAMMING/INSTALLATION. NOTE: FIRE ALARM PANEL TO BE UPGRADED TO SIMPLEX # 4001. 1404 IN 1 NOTE: FOR REFERENCE ONLY. THE EG SHALL COORDINATE WITH THE AUTOMATED LOGIC EMS PANEL SHOP DRAWINGS. 1.1 SALES TRACK LIGHTING TO LOADS 11-0 LATCH Ll1-0 UNLATCH 1.2 SALES MONOPOINTS AND RECESSED LIGHTING 1 t TO LOADS SHOW WINDOW LIGHTING 11-0 LATCH L11-0 UNLATCH 1.3 SHOW WINDOW LIGHTING AUTOMATED LOGIC CONTROLS EMS now INTERIORS LTD E.2 SCALE: NO SCALE Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 • 1946 F. 860. 678. 7111 nidesign@nidesign.net © 2013 0--A110 TO LOADS Lu 0 N z R 1 1-1-0-A:8 LATCH L-11-0 UNLATCH 1.4 STOREFRONT SIGNS SECURITY SHELVING NOTES: I. G.G. TO PROVIDE I" CONDUIT FROM EXISTING TELEPHONE SERVICE MAIN TO SECURITY SHELVING UNIT LOCATION 2. G.G. TO PROVIDE POWER AT THIS LOCATION A5 SPECIFIED AND POWER MUST BE ACTIVE PRIOR TO SECURITY EQUIPMENT CONTRACTOR'S INSTALLATION. 3. G.G. MUST BE ON SITE TO RECEIVE SECURITY EQUIPMENT DELIVERY. Z zz TO LOADS WIRING BY CONTR. (TYP) 11-0 LATCH LI Ho UNLATCH 1.5 HUTCH LIGHTING 0-A:12 °-A:14 SURFACE MOUNTED DOUBLE DUPLEX RECEPTACLES FRT PLYWOOD BACKBOARD ALL DEVICES SHALL BE SURFACE MOUNTED CONSULTANTS 12035 COLWICK Project Management* Design SAN ANTONIO, TX 78216 YANKEE CANDLE COMPANY - SEATTLE, WA NEC LOAD ANALYSIS AT EXISTING 200 AMP 120/208V/3W/4W ELECTRICAL SERVICE ITEM CONN. LOAD (VA) DEMAND F. DEMAND LOAD (WATTS) TOTAL (AMPS) LIGHTING 2410.0 125% 3112.0 , FIRST I0KW REGEPT 6620.0 100% 6620.0 REMAINING REGEPT E1 50% LIGHTALARMS WATER HEATERS 150.0 100% 150.0 MISC. LOADS 540.0 100% 540.0 HVAC LOADS 1000.0 100% 1000.0 SUB -TOTAL I x400.0 2 20022.0 25% OF LARGEST MOTOR 115.0 25% 115.0 TOTAL co I20/208V 3PH INTERIOR MALL SCONCE HUBBARTON FORGE 20117.0 56.1 Lighting Fixture Schedule Sym. Description Mfg Model Lamp ATGP V SALES FLOOR HEAD CONTEGH GTL603A-P-201/ LED17E26P3830KNFL LED 1711 PAR38 FLOOD - 3000K D1 SALES FLOOR MONOPOINT GONTEGH GTL603A-P-2011 4 LAIBP TGP LEDI7E26P3830KNFL LED 1711 PAR.% NARROW FLOOD - 3000K E1 LED .WHITE THERMOPLASTIC EXIT SIGN LIGHTALARMS NAQLXN500R-N 120 LED (INCLUDED) 1 COMBINATION BATHROOM EXHAUST FAN AND LIGHT GROAN 616 IOOW GFL FL G 6" RECESSED DOWNLIGHT WITH WHITE TRIM GONTEGH RL38-2011 4 GTR300I-114T TGP LEDI1E26P3830KNFL LED I1W PAR38 FLOOD - 5000K 2 CHAIN HUNG 'TS' FIXTURE AT STOCKROOM MERCURY MM-232-OGT-G-ELBL-UNI PHILIPS F32T8/ADV835/XLL (2) L IIORI INTERIOR MALL SCONCE HUBBARTON FORGE 20-6251 120 PHILIPS 2810 1/2 END/GL 2100K 0z-4 SALES FLOOR 2 -HEAD GLC. MOUNTED EM. LIGHT FIXTURE WITH INTEGRAL BATTERY GONTECH EL2HAIOW SELF CONTAINED HALOGEN LAMP Kl STOCKROOM 2 -HEAD EMERGENCY LIGHT PACK LIGHTALARMS LCA -25Q 120 5.4 WATT HALOGEN (INCLUDED) 380 #I2 Vl RJ11 V3, V1 RJ11 6j til 4n� 11 TO CASHWRAP TO MANAGER'S DESK D1, D2 D3, RJ45 (TO CASHWRAP 17 sr CI.111. r.7,. wmrul6euua51r:�5', SECURITY MULTIPLEXER SECURITY 15" MONITOR GD PLAYER, ROUTER , STEREO EQUIPMENT 20" FAX/COPY/ PRINTER REVIEW tE WjTH CpMPLI 70 NEC NEPA JUN 0 5 2t113 City of Tukwila 2 E.2 SECURITY SHELVING ELECTRICAL LAYOUT SCALE: NO SCALE IDllZd`.I' '1111\1G '1 -1 j P,N,,,n I nI .: date: deecr"ilpflon: 5 . 6 . 13 ISSUED TO CLIENT FOR FINAL REVIEW 5 . 7 . 13 ISSUED TO LANDLORD FOR FINAL REVIEW 5 . 10 . 13 ISSUED FOR BID 8 PERMIT EXISTING PANEL "A" PANELBOARD SCHEDULE 120/208V 3PH 4W CONNECTED VOLT -AMPS LOAD SERVED GKT # GKT BKR WIRE SIZE PHASE A PHASE B PHASE G PHASE A PHASE B PHASE G WIRE SIZE GKT SKR GKT # LOAD SERVED GASH REGISTER 1 20 #12 300 700 #I2 20 2 TRACK LTG GASH REGISTER 3 20 #I2 300 650 #12 20 4 TRACK LTG MGR'S DESK RECEPTS 5 20 #I2 360 380 #I2 20 6 SALES LTG LAN REGEPTS 7 20 #I2 360 540 #I2 20 8 SIGNS/SCONCES LAN REGEPTS 1 20 #I2 360 210 #12 20 10 STOREFRONT LTG LAN REGEPTS II 20 #I2 360 650 #12 20 12 STKRM/TOILET LTG LAN REGEPTS 13 20 #12 360 100 #I2 20 14 HUTCH RECEPTS SHOW WIN/SALES REGEPTS 15 20 #12 120 500 *12 20 16 HUTCH REGEPTS REF IGERATOR 17 20 #I2 200 600 #12 20 18 SPARE SALES AREA REGEPT/BUZZER 11 20 #12 280 100 #12 20 20 LIGHTING CONTACTOR (EMS) HVAC SERVICE REGEPT 21 20 #I2 360 100 012 20 22 CONTROLS GATEWAY (EMS) WATER HEATER 23 20 #I2 750 200 #12 20 24 FIRE ALARM PNL SPARE 25 20 #I2 180 20 26 SPARE SPARE 27 20 #I2 180 20 28 SPARE SPARE 21 20 20 30 SPARE SPARE 31 20 20 32 SPARE SPARE 33 20 20 34 SPARE RTU -I 35 #8 3000 20 36 SPARE 37 40 #8 3000 38 SPACE 31 #8 3000 40 SPACE SPACE 41 42 SPACE TOTAL PHASE A 4480 2040 6520 TOTAL PHASE B 4120 1460 6380 TOTAL PHASE C 4610 1830 6500 TOTAL VOLT -AMPS 11400 DIVIDE TOTAL VA BY VOLTAGE 208 LINE TO LINE VOLT AMPS 13.26 DIVIDE TOTAL AMPS BY 3 PHASE MULTIPLIER 1.732 3 PHASE AMP 53.88 TOTAL CONNECTED LOAD 53.88 150 AMP M.L.O. PANEL FEEDER SIZE - EXISTING - SEE RISER DIAGRAM GENERAL RISER NOTES A. ELECTRICAL CONTRACTOR SHALL ENSURE COMPLIANCE WITH NEG 110.26 SPACES ABOUT ELECTRICAL EQUIPMENT AND NEC 408.0 CIRCUIT DIRECTORY OR GIRGUIT IDENTIFICATION. B. PROVIDE BREAKER LOCK -ON DEVICE FOR GIRGUIT BREAKERS SERVING EXIT AND EMERGENCY LIGHTING, SECURITY PANEL DEVICES AND GASH WRAP RECEPTACLES. G. PROVIDE TYPE -WRITTEN GIRGUIT DIRECTORY FOR ALL ELECTRICAL PANELS. D. PROVIDE PLACARD FOR EACH PIECE OF ELECTRICAL DISTRIBUTION EQUIPMENT INDICATING EQUIPMENT DESIGNATION, SYSTEM VOLTAGE AND PHASE INDICATION. E. ELECTRICAL EQUIPMENT SHALL BE FIELD MARKED TO WARN OF POTENTIAL ARG FLASH HAZARDS DURING MAINTENANCE PER NEG 110.16. LANDLORD'S ELECTRICAL ROOM YANKEE CANDLE COMPANY SPACE `(4) #4/0 GU 0 (1) #6 GROUND 2-1/2" CONDUIT (EXISTING) LANDLORD'S EXISTING DISTRIBUTION EQUIPMENT I50A 511 0 SHEET NOTES ELECTRICAL METERING EQUIPMENT, DISTRIBUTION EQUIPMENT AND ASSOCIATED ELECTRICAL FEEDERS ARE EXISTING TO REMAIN. ELECTRICAL CONTRACTOR SHALL PROVIDE ANY REQUIRED CIRCUIT BREAKERS PER THE PANEL SCHEDULE ON THIS SHEET. CONTRACTOR TO LABEL DISCONNECT AND METER WITH TENANT NAME AND ADDRESS (SPACE #204). 2. LIGHTING CONTROL PANEL "EMS" 15 NEW, PROVIDED BY YGG VENDOR, INSTALLED BY ELECTRICAL CONTRACTOR. 3. NEW (REMOVE EXIST) 40A/3P UNFUSED W.P. DISCONNECT AND CONDUCTORS ® NEW RTU. CONTRACTOR TO LABEL UNIT AND DISCONNECT WITH TENANT NAME AND ADDRESS (SPACE #204). 4. NEV FIRE ALARM CONTROL PANEL - TO BE SUPPLIED AND INSTALLED BY MALL REQUIRED FIRE ALARM CONTRACTOR. G.G. TO COORDINATE. O M.S. 120/ 208V 3PH 411 200A 511 150A FU (EXIST) (3) #8 GU O (I) #I0 CU GROUND I-1/4" CONDUIT (NEW) O RECEIVED CITY OF TUKWILA MAY 302013 PERMIT CENTER PANEL "A" 120/208V 3PH 411 I50A MLO 42 SPACE (EXISTING) ' (4) #4/0 GU O(I) #6 GROUND I 2-1/2" CONDUIT (EXISTING) NEW LIGHTING CONTROL PANEL "EMS" O LIGHTING CIRCUITRY NEW FAGP O Electrical Schedules and Risers 14Cili E:d ' 5 . 10 . 13 ' P""° clg '°'"" ° AS NOTED 3 ELECTRICAL RISER DIAGRAM E.2 SCALE: NO SCALE I� EL\o s).2. #644 Westfield South Center Seattle, WA 1,647 fir' " 13064 file: /0869 JIMMY L. POWERS STATE OF WASHINGTON Cpl' new INTERIORS LTD LIGHTING A A = FIXTURE TYPE 0 a = SWITCH LEG p EMERGENCY SELF CONTAINED DOWN LIGHT [t EMERGENCY BATTERY UNIT, WALL MOUNTED BATTERY POWERED LIGHT EXIT LIGHT FIXTURE - UNIVERSAL MOUNTING (INDICATES DIRECTION ARROWS) EXIT LIGHT FIXTURE - WALL MOUNTING (INDICATES DIRECTION ARROWS) 4 TRACK HEAD WITH MONOPOINT CANOPY TRACK HEAD WITH TRACK SYSTEM AND COMPONENTS SWITCHING SINGLE POLE SWITCH (WITH FOLLOWING SWITCH DESIGNATIONS) WALL MOUNTED AT 42" A = SWITCH LEG 3 = THREE WAY 4 = FOUR WAY M = MANUAL MOTOR STARTER WITH THERMAL OVERLOADS E = EMERGENCY PULL SWITCH K = KEY OPERATED SWITCH D = DIMMER SWITCH OS OCCUPANCY SENSOR 0 TIME CLOCK NOTE: NOT ALL SYMBOLS LISTED ABOVE ARE SHOWN ON PLANS. THE SYMBOL LEGEND 15 USED FOR REFERENCE OF SYMBOLS SHOWN ON PLANS. SEE SPECIFICATIONS FOR INFORMATION RELATED TO SYMBOLS. POWER DISTRIBUTION DEVICES PANELBOARD - SURFACE/FLUSH MOUNTED, 12" TO TOP STEP-DOWN TRANSFORMER X e - SPECIAL RECEPTACLE, 18" AFF UNLESS NOTED OTHERWISE (UNO) SIMPLEX RECEPTACLE, 18" AFF UNO DUPLEX RECEPTACLE, 20A, 5262, 18" AFF UNO FOURPLEX RECEPTACLE, 20A, 5262, 18" AFF UNO RECEPTACLE WITH GROUND FAULT INTERCEPT, 18" AFF 'CFI UNO o WEATHERPROOF RECEPTACLE, 16" AFF UNO �IYGVi"' ISOLATED GROUND RECEPTACLE, 18" AFF UNO FLOOR BOX - COORDINATE LOCATION WITH FIXTURE LAYOUT 00 CEILING MOUNTED RECEPTACLE 0 MOTOR OR EQUIPMENT CONNECTION DISCONNECT 511ITGH COMBINATION MOTOR STARTER METER TRACK CURRENT LIMITING DEVICE (LIGHTOLIER GU? OR EQUAL) GENERAL WIRING DEVICES ------ CONDUIT SYSTEM UNDER FLOOR �\ HOMERUN. CONDUIT SYSTEM TO PANEL AS NOTED ON DRAWINGS 0 JUNCTION BOX 0----- CONDUIT UP �-- CONDUIT DOWN CABLING: IN = GATSe GABLE TO SYSTEMS BOARD IN 3/4"G TO 6" ABOVE CEILING, WITH INSULATED BUSHING. 113 = I "IBID" GABLE TO SYSTEMS BOARD IN 3/4"C TO 6" ABOVE GEILING, WITH INSULATED BUSHING. IF NO CABLING 16 NOTED, PROVIDE 3/4"G TO 6" ABOVE CEILING. PROVIDE INSULATED BUSHING AND PULL STRING. FIRE ALARM HORWSTROBE STROBE SD SMOKE DETECTOR, CEILING MOUNTED SECURITY AND COMMUNICATION T.T.3. mummom TELEPHONE TERMINAL BOARD - 3/4" X 4' X 8' FIRE TREATED PLYWOOD PAINTED WHITE TELEPHONE OUTLET LOCATION, 3/4" CONDUIT WITH a PULLWIRE TO ABOVE ACCESSIBLE CEILING, GAT 5E GABLE TO SYSTEMS BOARD TELEPHONE/DATA OUTLET LOCATION, 3/4" CONDUIT WITH PULLWIRE TO ABOVE ACCESSIBLE CEILING, GAT 5E GABLE TO SYSTEMS BOARD DATA OUTLET LOCATION, PROVIDE 4" 5Q. BOX, 3/4" 44 CONDUIT WITH PULLWIRE TO CEILING, GAT 5E GABLE TO SYSTEMS BOARD SPEAKER LOW VOLTAGE TRANSFORMER SECURITY KEYPAD BUZZER PUSH BUTTON x KP T B1\ 0 0 TAGS BELL SECURITY SYSTEM CAMERA SHEET IDENTIFIER XX SHEET NOTE COMPLIANCE WITH NFPA 70 - NEC JUN 0 5 2013 City of.Tukw;is City of.Ti kwila BUILDING DIVISION Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 - 1946 F. 860. 678. 7111 e ni C 2013 e i O .net i rud s ds CONSULTANTS Project Management * Design 12035 COLWICK SAN ANTONIO, TX 78216 wt"' I ONC1„.00 yla' cp: des :l. 5 . 6 . 13 ISSUED TO CLIENT FOR FINAL REVIEW 5 . 1 . 13 ISSUED TO LANDLORD FOR FINAL REVIEW 5 . 10 . 13 ISSUED FOR BID 4 PERMIT TENANT CRITERIA AND LANDLORD NOTES • THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE TO OBTAIN A COPY OF THE MALL'S TENANT CRITERIA HANDBOOK. • THE ELECTRICAL INSTALLATION MUST MEET ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, LOCAL AUTHORITY HAVING JURISDICTION AND LANDLORD'S INSURANCE PROVIDER(5). • NO APPURTENANCES (INCLUDING LIGHT FIXTURES, ANTENNAS, SIGNS, ETG.) SHALL BE AFFIXED TO THE EXTERIOR WALLS OR ROOF OF LANDLORD'S BUILDING WITHOUT PRIOR APPROVAL FORM THE TENANT REVIEW COORDINATOR. • SPECIAL CARE MUST BE TAKEN TO PROTECT SHOPPING CENTER FLOORING, DOORWAYS, AND CEILINGS. ALL CARTS, DOLLIES, ETC., MUST HAVE RUBBER WHEELS. WHEELBARROWS OR OTHER WHEELED VEHICLES WITHOUT RUBBER WHEELS ARE STRICTLY PROHIBITED. ANY DAMAGE REPAIRS OR CLEANUP OF DEBRIS WHICH MUST BE HANDLED BY LANDLORD SHALL BE AT THE 50LE COST AND EXPENSE OF TENANT, PLUS A 20% ADMINISTRATIVE FEE. • LOUD NOISES WILL NOT BE TOLERATED DURING SHOPPING CENTER HOURS. • NO ONE 15 ALLOWED ON THE SHOPPING GEN 1 ER ROOF WITHOUT PRIOR WRITTEN APPROVAL FROM LANDLORD. • CONTRACTOR MUST RECEIVE PRIOR PERMISSION OF LANDLORD FOR WORK AFTER NORMAL WORKING HOURS. • CONTRACTOR, AND EMPLOYEES MUST PERFORM WORK IN A PROFESSIONAL MANNER. UNPROFESSIONAL BEHAVIOR, (I.E., PROFANITY, SPITTING, ETC.), WILL NOT BE TOLERATED AND WILL RESULT IN THE SHUT -DOWN OF THE JOB SITE UNTIL THE UNPROFESSIONAL CONTRACTOR/EMPLOYEE IS REMOVED AND NEV CONTRACTOR/EMPLOYEE IS EMPLOYED. ALL CONSTRUCTION PERSONNEL ARE REQUIRED TO WEAR SHIRTS AND SHOES AT ALL TIMES. • LANDLORD AND LANDLORD'S AGENT RESERVES THE RIGHT TO STOP WORK IN PROGRESS FOR VIOLATIONS OF THE RULES AND REGULATIONS. • ACCESS TO LANDLORD'S SWITGHGEAR IS RESTRICTED AND MUST BE SCHEDULED WITH SHOPPING CENTER MANAGEMENT. INTERRUPTION OF POWER TO EXISTING TENANTS MUST HAVE LANDLORD'S PRIOR APPROVAL • ALL SIGN, LOGO AND SHOW WINDOW ILLUMINATION MUST BE CONTROLLED BY AN AUTOMATIC TIMEGLOGK. • NIGHT LIGHTING SHALL BE DESIGNED AND INSTALLED, RESULTING IN LOW LEVEL ILLUMINATION THROUGHOUT THE SPACE WHEN THE STORE IS CLOSED. • TENANT'S ELECTRICAL SYSTEM SHALL BE GROUNDED TO STEEL STRUCTURE PER THE NATIONAL ELECTRICAL CODE. TENANT'S CONTRACTOR SHALL REPAIR STEEL FIREPROOFING (IF APPLICABLE). • TENANT SHALL PROVIDE AND INSTALL A COMPLETE ELECTRICAL SYSTEM AND PERFORM ALL REQUIRED WORK WHIGH MAY INCLUDE, BUT 15 NOT LIMITED TO, FUSED DISCONNECT SWITCH, METER PAN AND SOCKET, METER, CONDUIT AND WIRE FROM LANDLORD'S DESIGNATED DISTRIBUTION POINT TO AND WITHIN THE PREMISES, AND ALL WIRING AND CONNECTIONS FROM THE CENTRAL DISTRIBUTION PANELS, LIGHTING PANELS, ALL FEEDER CONDUCTORS, ANY REQUIRED TRANSFORMERS, ALL CONDUIT AND WIRING FOR POWER DISTRIBUTION WITHIN THE LEASED PREMISES, LIGHTING FIXTURES, RECEPTACLES, SWITCHES AND MISCELLANEOUS DEVICES REQUIRED WITHIN THE PREMISES. • ALL ELECTRICAL WORK WILL CONFORM TO BUILDING DESIGN PARAMETERS AND ALL APPLICABLE GOVERNMENTAL REGULATIONS INCLUDING ENERGY CONSERVATION GODES. WHERE PREVIOUSLY EXISTING ELECTRICAL COMPONENTS ARE TO BE REUSED, TENANT ACCEPTS ALL EXISTING ELECTRICAL COMPONENTS IN AN "AS -I5" CONDITION AND WILL REPLACE, REPAIR OR REFURBISH THESE COMPONENTS TO A "LIKE -NEW" CONDITION ADEQUATE FOR THE OCCUPANCY OF THE PREMISES AND COMPLIANT WITH BUILDING DESIGN PARAMETERS AND ALL GOVERNMENTAL REGULATIONS. • ALL MODIFICATIONS TO THE EXISTING SYSTEM WITHIN THE DEMISED PREMISES SHALL BE BY TENANT'S CONTRACTOR. TENANT'S CONTRACTOR ACCEPTS EXISTING SYSTEM IN "A5 -I5" CONDITION AND 15 RESPONSIBLE FOR DETERMINING THE ADEQUACY OF ANY EQUIPMENT OR SYSTEM WHICH TENANT'S CONTRACTOR CHOOSES TO REUSE. ANY EQUIPMENT OR SYSTEM COMPONENTS WHICH TENANT'S CONTRACTOR INTENDS TO USE OR REUSE SHALL BE CLEARLY DESIGNATED A5 SUCH ON TENANT'S DRAWINGS. • INSTALLATION SHALL CONFORM TO THE FOLLOWING: A. ELECTRICAL PANELS SHALL HAVE COFI✓ER BUS BARS AND BOLT -IN BREAKERS. LOAD CENTERS ARE NOT PERMI 1 I EV. THE NATIONAL ELECTRICAL CODE REQUIRES THAT LIGHTING PANELS CONTAIN CIRCUIT BREAKERS RATED FOR SWITCHING DUTY. B. PANEL BOARDS SHALL BE DESIGNED FOR A MINIMUM OF 25% EXCESS CAPACITY BASED ON CONNECTED LOAD. TENANT SHALL PROVIDE 20% SPARE BREAKER SPACE. • ENGRAVED, MECHANICALLY ATTACHED NAME PLATES SHALL BE INSTALLED ON EACH PANELBOARD, TRANSFORMER, DISCONNECT SWITCH, MOTOR STARTER, ETC. • A CONVENIENCE RECEPTACLE AND SWITCHED LIGHT FIXTURE SHALL BE INSTALLED ADJACENT TO ALL ROOF MOUNTED MECHANICAL EQUIPMENT. • TENANT SHALL PROVIDE CONDUIT AND WIRING FOR THE PROVISION OF TELEPHONE AND GABLE (IF AVAILABLE) SERVICE TO THE LEASED PREMISES FROM THE LANDLORD'S DESIGNATED TELEPHONE UTILITY DISTRIBUTION PANEL TO AND WITHIN THE PREMISES. TENANT SHALL FURNISH AND INSTALL ALL TELEPHONE AND GABLE EQUIPMENT, CONDUIT AND WIRING, OUTLET BOXES AND DEVICES WITHIN THE LEASED PREMISES. TENANT SHALL MAKE ALL NECESSARY ARRANGEMENTS DIRECTLY WITH THE APPROPRIATE TELEPHONE AND GABLE SERVICE PROVIDER(5). ALL TELEPHONE WIRE AND CABLE OUTSIDE OF THE LEASED PREMISES SHALL BE ROUTED THROUGH CONDUIT FROM THE APPLICABLE UTILITY DISTRIBUTION POINT TO AND WITHIN THE PREMISES BY THE TENANT. ALL TELEPHONE AND CABLE WIRING IN THE PREMISES SHALL BE PLENUM RATED. • ALUMINUM WIRING 15 NOT PERMITTED. ALL WIRING BY TENANT SHALL BE COPPER. TENANT SHALL INSTALL ONLY TYPE R CURRENT LIMITING FUSES. ALL FEEDER CONDUCTORS SHALL BE COPPER. INSULATION SHALL BE TYPE THHN, THIN. • ALL PANELBOARDS, LIGHTING FIXTURES, RECEPTACLES, LIGHTING SWITCHES, DISCONNECT SWITCHES AND OTHER ELECTRICAL EQUIPMENT SHALL BE U.L. APPROVED. • TENANT'S ELECTRICAL CONTRACTOR'S INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA AND ALL OTHER APPLICABLE GODES. LANDLORD'S APPROVAL OF ELECTRICAL DRAWINGS 15 NOT TO BE INTERPRETED A5 STATEMENT OF COMPLIANCE WITH CODE REQUIREMENTS. • NO PVG JACKETED CABLE SHALL BE PERMITTED ABOVE HUNG CEILINGS UNLESS RUN THROUGH A CONDUIT SYSTEM. • ALL EXPOSED WIRING SHALL BE IN CONDUITS. • TENANT SHALL FURNISH LANDLORD WITH TWO COPIES OF AN ELECTRICAL SUMMARY, ELECTRICAL PANELBOARD SCHEDULE, ELECTRICAL EQUIPMENT SCHEDULES AND OTHER RELATED REPORTS. • ALL WIRING SHALL BE IN EMT OR RIGID CONDUIT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED GABLE, ETG ALLOWED. • WALL SWITCHES SHALL BE 20 AMP, 120/211 VOLT RATING. USE LEVITON SERIES 1221 THROUGH 1224 OR EQUAL SERIES BY SIERRA OR HUBBELL. • THE TENANT/TENANT'S GENERAL CONTRACTOR 15 RESPONSIBLE TO ENSURE THAT THERE ARE NO UNDERGROUND UTILITIES OR OTHER SERVICES BEFORE CUTTING ANY CONCRETE, ANYWHERE ON THE PROPERTY. THE TENANT WILL BE LIABLE FOR ALL REPAIRS AND/OR LOST BUSINESS DUE TO A UTILITY OR SERVICE INTERRUPTION A5 A RESULT OF CUTTING THE SLAB. RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER 11'!' fiI Electrical Legends and Notes 5. 10. 13 clg aiy� 4 °;w',.:ak : AS NOTED ! x:r, #204 ELtO 5.2„2--- 1E #644 Westfield South Center Seattle, WA 'i Il';,, „"VI.. 1,647 Ii,! ° I;::; 'iil;jp! 13064 JIMMY L. POWERS STATE OF WASHINGTON In ,11.11:11111111,1,1111111111111,11111.11.11111 E. GENERAL NOTES: POWER & LIGHTING I. FIELD VERIFY ALL CONDITIONS. 15. ALL 20A BRANCH CIRCUITS BETWEEN 100' AND 150' IN LENGTH, #10 AWS WIRE SHALL BE USED. FOR ALL 20A BRANCH CIRCUITS OVER 150' IN LENGTH, #8 AWG WIRE SHALL BE 2. DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO USED. BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD 16. ALL 20A BRANCH CIRCUITS LESS THAN 100' IN LENGTH, SHALL BE #I2 CONDUCTORS, #12 MODIFICATIONS DUE TO EXISTING CONDITIONS. CND., 3/4" UNLESS NOTED OTHERWISE. 3. THE CONTRACTOR SHALL CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS 11. CIRCUITING INDICATED ON PLAN 15 PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE SHALL BE "THRU-WIRING" WHERE/WHEN POSSIBLE. MULTI -CONNECTIONS TO A SINGLE LIGHT DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER FIXTURE FOR FIELD CONDITIONS OR VOLTAGE DROP FACTORS MAY BE REQUIRED BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. (FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU-WIRING"), AND RELA 1 EV COSTS SHALL BE INCLUDED IN ELECTRICAL CONTRACTORS BID. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL GODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS. THE COSTS FOR ALL WORK INSTALLED IN 18. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT LIGHT FIXTURES. WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING GODES AND DESIGN INTENT.' Iq. EMERGENCY LIGHTS SHALL BE INSTALLED AND CIRCUITED PER N.E.G. AND ALL LOCAL GODES. ALL EMERGENCY FIXTURES SHALL BE DUAL VOLTAGE (120/211 AUTO XFMR) 5. MINOR VARIATIONS DUE TO UNFORESEEN CONDITIONS THAT MAY EFFECT THE BATTERY BACK-UP UNITS. INSTALL CENTRAL BATTERY BACK-UP ONLY IF INDIVIDUAL UNITS CONTRACTOR'S SCOPE OF WORK, REQUIRED FOR ACCOMPLISHING THE INTENT OF THIS ARE PROHIBITED BY LOCAL GODES, CLOSELY COORDINATE WITH TENANT CONSTRUCTION DESIGN SHALL BE INCLUDED IN CONTRACTOR'S PRICING. MANAGER. 6. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL REQUIRED PERMITS. 20. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS A5 CONTRACTOR'S INSTALLATION SHALL CONFORM TO ALL LOCAL CODE REQUIREMENTS. REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. 1. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT PLACEMENT OF ALL DEVICES SHOWN OF 21. WHERE DRYWALL CEILINGS ARE USED, ELECTRICAL CONTRACTOR SHALL ARRANGE THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MECHANICAL AND CIRCUITING 50 THAT JUNCTION BOXES ACCESS PANELS ARE NOT REQUIRED IN THESE PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT. DRYWALL CEILING AREAS. (THE USE OF JUNCTION BOXES IN THESE DRYWALL CEILINGS IS 8. CONTRACTOR SHALL BEGONE FAMILIAR WITH REQUIRED DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL DEMOLITION A5 REQUIRED FOR INSTALLATION OF NEW WORK. NOT PERMITTED, ARRANGE CIRCUITS TO AVOID THIS SITUATION). FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER PRIOR TO ROUGH -IN TO AVOID CONFLICTS. JUNCTION BOXES MAY BE PLACED ABOVE LAY -IN CEILINGS. q. CONTRACTOR SHALL COORDINATE INSTALLATION OF ELEGTRIGAL WORK ABOVE THE CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF PLUMBING AND MECHANICAL INSTALLATION. CONDUIT RUNS TO BE RUN THROUGH TRUSSES 22. FIELD VERIFY EXACT LOCATION AND ELEGTRIGAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR, PRIOR TO ORDERING RELATED ELEGTRIGAL EQUIPMENT. WHERE POSSIBLE. 23. PLACEMENT OF ALL RECEPTACLES SHALL BE INTENTIONAL (I.E. CENTERED ON COLUMNS OR 10. COORDINATE EXACT LOCATION OF DEVICES SERVING CASEWORK WITH CASEWORK CONTRACTOR. WALL FEATURES, OR TIGHT TO CORNER). IF RECEPTACLE 15 NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S CONSTRUCTION MANAGER PRIOR TO RECEPTACLE BOX ROUGH -IN. II. COORDINATE ALL LOW VOLTAGE CONDUIT AND ROUGH -IN REQUIREMENTS WITH LOW 24. INSTALLATION OF LIGHTING FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S VOLTAGE CONTRACTORS. RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. 12. SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, TRANSFORMER AND CONTACTORS 25. ALL FIXTURES SCHEDULED MAY NOT NECESSARILY BE USED ON THIS PROJECT. REFER TO SHALL BE "LISTED" AND "IDENTIFIED" AS RATED FOR A MINIMUM OF 15I4G CONDUCTOR LIGHTING PLAN. TERMINATION. 13. ELEGTRIGAL CONTRACTOR SHALL INCLUDE EQUIPMENT GROUND CONDUCTOR IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH N.E.G. 26. PROVIDE ALL NECESSARY COMPONENTS TO MAKE A COMPLETE WORKING SYSTEM. VERIFY ROW LENGTHS, FEED POINT AND MOUNTING REQUIREMENTS PRIOR TO ORDERING. 14. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH A PULL WIRE. 21. TAKE ADEQUATE CARE TO CORRECTLY LOCATE ALL ELECTRICAL STUBOUTS, FLOOR BOXES, J -BOXES, TRACK, ETG. PRECISE LOCATIONS OF FLOOR OUTLETS AND J -BOXES 15 VERY IMPORTANT. ALL GAT -5 WIRE TO BE PROVIDED BY OWNER'S VENDOR. Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 - 1946 F. 860. 678. 7111 e ni C 2013 e i O .net i rud s ds CONSULTANTS Project Management * Design 12035 COLWICK SAN ANTONIO, TX 78216 wt"' I ONC1„.00 yla' cp: des :l. 5 . 6 . 13 ISSUED TO CLIENT FOR FINAL REVIEW 5 . 1 . 13 ISSUED TO LANDLORD FOR FINAL REVIEW 5 . 10 . 13 ISSUED FOR BID 4 PERMIT TENANT CRITERIA AND LANDLORD NOTES • THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE TO OBTAIN A COPY OF THE MALL'S TENANT CRITERIA HANDBOOK. • THE ELECTRICAL INSTALLATION MUST MEET ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, LOCAL AUTHORITY HAVING JURISDICTION AND LANDLORD'S INSURANCE PROVIDER(5). • NO APPURTENANCES (INCLUDING LIGHT FIXTURES, ANTENNAS, SIGNS, ETG.) SHALL BE AFFIXED TO THE EXTERIOR WALLS OR ROOF OF LANDLORD'S BUILDING WITHOUT PRIOR APPROVAL FORM THE TENANT REVIEW COORDINATOR. • SPECIAL CARE MUST BE TAKEN TO PROTECT SHOPPING CENTER FLOORING, DOORWAYS, AND CEILINGS. ALL CARTS, DOLLIES, ETC., MUST HAVE RUBBER WHEELS. WHEELBARROWS OR OTHER WHEELED VEHICLES WITHOUT RUBBER WHEELS ARE STRICTLY PROHIBITED. ANY DAMAGE REPAIRS OR CLEANUP OF DEBRIS WHICH MUST BE HANDLED BY LANDLORD SHALL BE AT THE 50LE COST AND EXPENSE OF TENANT, PLUS A 20% ADMINISTRATIVE FEE. • LOUD NOISES WILL NOT BE TOLERATED DURING SHOPPING CENTER HOURS. • NO ONE 15 ALLOWED ON THE SHOPPING GEN 1 ER ROOF WITHOUT PRIOR WRITTEN APPROVAL FROM LANDLORD. • CONTRACTOR MUST RECEIVE PRIOR PERMISSION OF LANDLORD FOR WORK AFTER NORMAL WORKING HOURS. • CONTRACTOR, AND EMPLOYEES MUST PERFORM WORK IN A PROFESSIONAL MANNER. UNPROFESSIONAL BEHAVIOR, (I.E., PROFANITY, SPITTING, ETC.), WILL NOT BE TOLERATED AND WILL RESULT IN THE SHUT -DOWN OF THE JOB SITE UNTIL THE UNPROFESSIONAL CONTRACTOR/EMPLOYEE IS REMOVED AND NEV CONTRACTOR/EMPLOYEE IS EMPLOYED. ALL CONSTRUCTION PERSONNEL ARE REQUIRED TO WEAR SHIRTS AND SHOES AT ALL TIMES. • LANDLORD AND LANDLORD'S AGENT RESERVES THE RIGHT TO STOP WORK IN PROGRESS FOR VIOLATIONS OF THE RULES AND REGULATIONS. • ACCESS TO LANDLORD'S SWITGHGEAR IS RESTRICTED AND MUST BE SCHEDULED WITH SHOPPING CENTER MANAGEMENT. INTERRUPTION OF POWER TO EXISTING TENANTS MUST HAVE LANDLORD'S PRIOR APPROVAL • ALL SIGN, LOGO AND SHOW WINDOW ILLUMINATION MUST BE CONTROLLED BY AN AUTOMATIC TIMEGLOGK. • NIGHT LIGHTING SHALL BE DESIGNED AND INSTALLED, RESULTING IN LOW LEVEL ILLUMINATION THROUGHOUT THE SPACE WHEN THE STORE IS CLOSED. • TENANT'S ELECTRICAL SYSTEM SHALL BE GROUNDED TO STEEL STRUCTURE PER THE NATIONAL ELECTRICAL CODE. TENANT'S CONTRACTOR SHALL REPAIR STEEL FIREPROOFING (IF APPLICABLE). • TENANT SHALL PROVIDE AND INSTALL A COMPLETE ELECTRICAL SYSTEM AND PERFORM ALL REQUIRED WORK WHIGH MAY INCLUDE, BUT 15 NOT LIMITED TO, FUSED DISCONNECT SWITCH, METER PAN AND SOCKET, METER, CONDUIT AND WIRE FROM LANDLORD'S DESIGNATED DISTRIBUTION POINT TO AND WITHIN THE PREMISES, AND ALL WIRING AND CONNECTIONS FROM THE CENTRAL DISTRIBUTION PANELS, LIGHTING PANELS, ALL FEEDER CONDUCTORS, ANY REQUIRED TRANSFORMERS, ALL CONDUIT AND WIRING FOR POWER DISTRIBUTION WITHIN THE LEASED PREMISES, LIGHTING FIXTURES, RECEPTACLES, SWITCHES AND MISCELLANEOUS DEVICES REQUIRED WITHIN THE PREMISES. • ALL ELECTRICAL WORK WILL CONFORM TO BUILDING DESIGN PARAMETERS AND ALL APPLICABLE GOVERNMENTAL REGULATIONS INCLUDING ENERGY CONSERVATION GODES. WHERE PREVIOUSLY EXISTING ELECTRICAL COMPONENTS ARE TO BE REUSED, TENANT ACCEPTS ALL EXISTING ELECTRICAL COMPONENTS IN AN "AS -I5" CONDITION AND WILL REPLACE, REPAIR OR REFURBISH THESE COMPONENTS TO A "LIKE -NEW" CONDITION ADEQUATE FOR THE OCCUPANCY OF THE PREMISES AND COMPLIANT WITH BUILDING DESIGN PARAMETERS AND ALL GOVERNMENTAL REGULATIONS. • ALL MODIFICATIONS TO THE EXISTING SYSTEM WITHIN THE DEMISED PREMISES SHALL BE BY TENANT'S CONTRACTOR. TENANT'S CONTRACTOR ACCEPTS EXISTING SYSTEM IN "A5 -I5" CONDITION AND 15 RESPONSIBLE FOR DETERMINING THE ADEQUACY OF ANY EQUIPMENT OR SYSTEM WHICH TENANT'S CONTRACTOR CHOOSES TO REUSE. ANY EQUIPMENT OR SYSTEM COMPONENTS WHICH TENANT'S CONTRACTOR INTENDS TO USE OR REUSE SHALL BE CLEARLY DESIGNATED A5 SUCH ON TENANT'S DRAWINGS. • INSTALLATION SHALL CONFORM TO THE FOLLOWING: A. ELECTRICAL PANELS SHALL HAVE COFI✓ER BUS BARS AND BOLT -IN BREAKERS. LOAD CENTERS ARE NOT PERMI 1 I EV. THE NATIONAL ELECTRICAL CODE REQUIRES THAT LIGHTING PANELS CONTAIN CIRCUIT BREAKERS RATED FOR SWITCHING DUTY. B. PANEL BOARDS SHALL BE DESIGNED FOR A MINIMUM OF 25% EXCESS CAPACITY BASED ON CONNECTED LOAD. TENANT SHALL PROVIDE 20% SPARE BREAKER SPACE. • ENGRAVED, MECHANICALLY ATTACHED NAME PLATES SHALL BE INSTALLED ON EACH PANELBOARD, TRANSFORMER, DISCONNECT SWITCH, MOTOR STARTER, ETC. • A CONVENIENCE RECEPTACLE AND SWITCHED LIGHT FIXTURE SHALL BE INSTALLED ADJACENT TO ALL ROOF MOUNTED MECHANICAL EQUIPMENT. • TENANT SHALL PROVIDE CONDUIT AND WIRING FOR THE PROVISION OF TELEPHONE AND GABLE (IF AVAILABLE) SERVICE TO THE LEASED PREMISES FROM THE LANDLORD'S DESIGNATED TELEPHONE UTILITY DISTRIBUTION PANEL TO AND WITHIN THE PREMISES. TENANT SHALL FURNISH AND INSTALL ALL TELEPHONE AND GABLE EQUIPMENT, CONDUIT AND WIRING, OUTLET BOXES AND DEVICES WITHIN THE LEASED PREMISES. TENANT SHALL MAKE ALL NECESSARY ARRANGEMENTS DIRECTLY WITH THE APPROPRIATE TELEPHONE AND GABLE SERVICE PROVIDER(5). ALL TELEPHONE WIRE AND CABLE OUTSIDE OF THE LEASED PREMISES SHALL BE ROUTED THROUGH CONDUIT FROM THE APPLICABLE UTILITY DISTRIBUTION POINT TO AND WITHIN THE PREMISES BY THE TENANT. ALL TELEPHONE AND CABLE WIRING IN THE PREMISES SHALL BE PLENUM RATED. • ALUMINUM WIRING 15 NOT PERMITTED. ALL WIRING BY TENANT SHALL BE COPPER. TENANT SHALL INSTALL ONLY TYPE R CURRENT LIMITING FUSES. ALL FEEDER CONDUCTORS SHALL BE COPPER. INSULATION SHALL BE TYPE THHN, THIN. • ALL PANELBOARDS, LIGHTING FIXTURES, RECEPTACLES, LIGHTING SWITCHES, DISCONNECT SWITCHES AND OTHER ELECTRICAL EQUIPMENT SHALL BE U.L. APPROVED. • TENANT'S ELECTRICAL CONTRACTOR'S INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA AND ALL OTHER APPLICABLE GODES. LANDLORD'S APPROVAL OF ELECTRICAL DRAWINGS 15 NOT TO BE INTERPRETED A5 STATEMENT OF COMPLIANCE WITH CODE REQUIREMENTS. • NO PVG JACKETED CABLE SHALL BE PERMITTED ABOVE HUNG CEILINGS UNLESS RUN THROUGH A CONDUIT SYSTEM. • ALL EXPOSED WIRING SHALL BE IN CONDUITS. • TENANT SHALL FURNISH LANDLORD WITH TWO COPIES OF AN ELECTRICAL SUMMARY, ELECTRICAL PANELBOARD SCHEDULE, ELECTRICAL EQUIPMENT SCHEDULES AND OTHER RELATED REPORTS. • ALL WIRING SHALL BE IN EMT OR RIGID CONDUIT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED GABLE, ETG ALLOWED. • WALL SWITCHES SHALL BE 20 AMP, 120/211 VOLT RATING. USE LEVITON SERIES 1221 THROUGH 1224 OR EQUAL SERIES BY SIERRA OR HUBBELL. • THE TENANT/TENANT'S GENERAL CONTRACTOR 15 RESPONSIBLE TO ENSURE THAT THERE ARE NO UNDERGROUND UTILITIES OR OTHER SERVICES BEFORE CUTTING ANY CONCRETE, ANYWHERE ON THE PROPERTY. THE TENANT WILL BE LIABLE FOR ALL REPAIRS AND/OR LOST BUSINESS DUE TO A UTILITY OR SERVICE INTERRUPTION A5 A RESULT OF CUTTING THE SLAB. RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER 11'!' fiI Electrical Legends and Notes 5. 10. 13 clg aiy� 4 °;w',.:ak : AS NOTED ! x:r, #204 ELtO 5.2„2--- 1E #644 Westfield South Center Seattle, WA 'i Il';,, „"VI.. 1,647 Ii,! ° I;::; 'iil;jp! 13064 JIMMY L. POWERS STATE OF WASHINGTON In ,11.11:11111111,1,1111111111111,11111.11.11111 E. 05/04/13 12:43 DIVISION 16: ELECTRICAL SPECIFICATIONS I6AI GENERAL INSTRUCTIONS I6A H GENERAL REQUIREMENTS. ALL REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. EACH CONTRACTOR SHALL BE RESPONSIBLE TO BECOME THOROUGHLY FAMILIAR WITH ALL ITS CONTENTS A5 TO REQUIREMENTS WHICH AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL MATERIAL, EQUIPMENT, APPLIANCES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO FACILITATE EACH SYSTEMS FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. I6A 1-2 DEFINITIONS. FURNISH: THE TERM "FURNISH" 15 USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SIGN, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, GLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE OWNER OR OTHERS. IT I5 TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" 15 THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND 15 A CONSULTANT TO, AND AND AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND/OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO THE INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT" AHJ: THE LOCAL CODE AND/OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. THE TERMS "APPROVED EQUAL", "EQUIVALENT", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER A5 EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, GSA), AND ACCEPTABLE TO THE AHJ OVER 11415 PROJECT. I6A 1-3 INSPECTION OF SITE. THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK 15 TO BE DONE. FAILURE TO DO 50 WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR. OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. I6A 1-4 MATERIAL AND WORKMANSHIP. ALL MATERIAL AND APPARATUS SHALL BE NEW AND IN FIRST GLASS CONDITION. ALL MATERIAL AND APPARATUS SHALL- HAVE MARKINGS OR A NAMEPLATE IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALL WORKMANSHIP SHALL BE OF THE FINEST 12055IBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, ALL MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTABLE. ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK SHALL BE FURNISHED BY THIS CONTRACTOR. MATERIAL AND EQUIPMENT SHALL BE STORK AND MAINTAINED IN CLEAN CONDITION, AND PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. J6A 1-5 COORDINATION. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER CONTRACTORS AND SUBCONTRACTORS 50 THAT VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL, STRUCTURAL AND MECHANICAL DRAWINGS AND TO RELEVANT EQUIPMENT DRAWINGS TO DETERMINE THE EXTENT OF CLEAR SPACES. THE CONTRACTOR SHALL MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS AND OTHER STRUCTURAL MEMBERS; AND TO FACILITATE CONGEALING CONDUIT IN THE MANNER ANTICIPATED IN THE DESIGN. THE CONTRACTOR SHALL PROVIDE MATERIALS WITH TRIM WHICH WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINICI IES ACTUALLY INSTAI 1 FT) J6A 1-6 DIMENSIONS AND LAYOUTS. THE DRAWINGS ARE SCHEMATIC IN NATURE, BUT SHOW THE VARIOUS COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HON THEY ARE TO BE INTEGRATED WITH OTHER PARTS OF THE, BUILDING. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALE DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY REVIEWING ALL CONTRACT DOCUMENTS. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS WHICH COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION. 16050-1 ORDINANCES AND CODES. CONTRACTORS PERFORMANCE, WORKMANSHIP AND MATERIALS SHALL COMPLY WITH NATIONAL FIRE PROTECTION ASSOCIATION CODES, STATE AND LOCAL BUILDING CODES, AND/OR ALL OTHER APPLICABLE CODES AND ORDINANCES. CONTRACTOR SHALL COMPLY WITH RULES AND REGULATIONS OF PUBLIC UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. OBTAIN AND PAY FOR ALL PERMITS. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY VIOLATION OF THE LAW. CONTRACTOR SHALL MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE SAFETY OF THE PUBLIC. J6A 1-8 SUBSTITUTIONS. TH15 SPECIFICATION PROVIDES THAT THE BASE BID OF ALL CONTRACTORS SHALL INCLUDE THE PRODUCTS SPECIFICALLY NAMED,; THE CONTRACTOR BEING PERMITTED TO SUBMIT IN THE FORM OF ALTERNATES, WITH HIS PROPOSAL, PRODUCTS OF ANY 011 IER MANUFACTURERS FOR SIMILAR USE, PROVIDED THE DIFFERENCE IN COST, IF ANY, 15 SPECIFIED IN EACH CASE. THE TERMS "APPROVED", "APPROVED EQUAL", OR "EQUAL" SHALL MEAN APPROVED BY THE ENGINEER A5 AN ACCEPTABLE ALTERNATE BID. NO SUBSTITUTIONS WILL BE CONSIDERED THAT ARE NOT BID A5 AN ALTERNATE. J6A I-4 SHOP DRAWINGS. SUBMIT FOR APPROVAL TWO SETS OF MANUFACTURERS SHOP DRAWINGS OF ALL MAJOR ITEMS OF EQUIPMENT AND ALL ITEMS REQUIRING COORDINATION BETWEEN CONTRACTORS. BEFORE SUBMITTING SHOP DRAWINGS AND MATERIAL LISTS, THE CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT SUBMITTED 15 MUTUALLY COMPATIBLE AND SUITABLE FOR THE INTENDED USE, AND SHALL FIT THE AVAILABLE SPACE AND ALLOW AMPLE ROOM FOR MAINTENANCE. THE ENGINEER'S CHECKING AND SUBSEQUENT APPROVAL OF SUCH SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, OR QUANTITIES; OR OMISSIONS OF COMPONENTS OR FITTINGS; OR FOR COORDINATING ITEMS WITH ACTUAL BUILDING CONDITIONS. OA 1-10 ADJUSTING. ALIGNING AND TESTING. ALL ELECTRICAL EQUIPMENT ON THIS PROJECT FURNISHED UNDER THIS DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS SHALL BE ADJUSTED, ALIGNED AND TESTED FOR PROPER OPERATION BY THE ELECTRICAL CONTRACTOR. COMPLETE WIRING SYSTEMS SHALL BE FREE FROM SHORT CIRCUITS. ALL MOTORS SHALL BE VERIFIED FOR PROPER ROTATION. THE CONTRACTOR SHALL MAINTAIN ON THE PROJECT PREMISES THE FOLLOWING AT ALL TIMES: A TRUE RMS READING VOLTMETER, A TRUE RM5 READING AMMETER, AND A MEGGER INSULATION RESISTANCE TESTER. THE CONTRACTOR SHALL PROVIDE TEST DATA READINGS A5 REQUESTED OR AS REQUIRED. I6A I-11 OPERATION ANP MAINTENANCE INSTRUCTIONS. SUBMIT TO THE OWNER (2) COPIES,I() LEFT AT STORE, (I) SUBMITTED TO YGG PROJECT MANAGER, EACH OF MATERIAL FOR MAINTENANCE AND OPERATION INSTRUCTION MANUALS, APPROPRIATELY BOUND INTO MANUAL FORM INCLUDING APPROVED COPIES OF THE FOLLOWING, REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS ACTUALLY INSTALLED. MANUFACTURERS CATALOG SHEETS WIRING DIAGRAMS MAINTENANCE INSTRUCTIONS OPERATING INSTRUCTIONS PARTS LISTS CONTRACTOR SHALL ALSO PROVIDE ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATION TO OWNERS REPRESENTATIVE AT THE TERMINATION OF THE WORK. I6A 1-12 START UP OF SYSTEMS. PRIOR TO STARTUP OF THE ELECTRICAL SYSTEMS, THE CONTRACTOR SHALL GHEGK ALL COMPONENTS AND DEVICES, LUBRICATE ITEMS ACCORDINGLY, AND TIGHTEN ALL SCREWED AND BOLTED CONNECTIONS. ADJUST TAPS 014 EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE. GHEGK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS, GROUNDING RESISTANCE AND PROPER PHASING. BALANCE ALL SINGLE PHASE LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE 15 ACHIEVED. new INTERIORS LTD Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860. 678 • 1946 F. 860. 678. 7111 nidesign@nidesign.net © 2013 I6A 1-13 GUARANTEE. GUARANTEE AGAINST DEFECTIVE WORKMANSHIP AND MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL PAYMENT. GUARANTEE SHALL INCLUDE MATERIAL TO BE REPLACED AND ALL LABOR REQUIRED. 16A 1-14 MISCELLANEOUS REMODELING WORK. PROVIDE ALL ITEMS OF ELECTRICAL SYSTEMS MODIFICATION REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER OPERATION. I6A2 ELECTRICAL INSTALLATION. I6A 2-1 EXCAVATION AND BAGKFILLING. 170 ALL EXCAVATION OF ALL MATERIALS ENCOUNTERED INCLUDING ROCK REQUIRED FOR WORK UNDER THIS SECTION. BACKFILL ALL TRENCHES, TAMPING WELL IN 6" LAYERS. SYSTEM SHALL BE TESTED, MADE TIGHT AND ACCEPTED BEFORE BACKFILL. REMOVE FROM PREMISES ALL EXCESS MATERIAL NOT USED IN BACKFILLING. REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING, ETC. DAMAGED. REPAIR MATERIALS SHALL GENERALLY MATCH EXISTING CONSTRUCTION. ALL BACKFILLING AND REPAIRING SHALL MEET ALL REQUIREMENTS OF THE CITY AND OTHERS HAVING JURISDICTION. REPAIR WORK SHALL BE THOROUGHLY FIRST GLASS. CONFORM TO ALL REQUIREMENTS OF DIVISION TWO OF THIS SPECIFICATION. 16A 2-2 GLEANING. DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE WORK SHALL BE REMOVED FROM THE PREMISES AS REQUIRED TO PREVENT ACCUMULATION. THE CONTRACTOR SHALL COOPERATE 114 MAINTAINING REASONABLY GLEAN PREMISES AT ALL TIMES. IMMEDIATELY PRIOR TO FINAL INSPECTION, THE CONTRACTOR SHALL MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM HIS WORK. THE CONTRACTOR SHALL CLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THE ELECTRICAL CONTRACT. DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER SHALL BE REMOVED FROM ALL SURFACES. DAMAGED FINISHES SHALL BE TOUGHED UP AND RESTORED TO THEIR ORIGINAL CONDITION. 16A 2-3 GUTTING AND PATCHING. THIS CONTRACTOR SHALL DO ALL GUTTING OF WALLS, FLOORS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. CONTRACTOR SHALL OBTAIN PERMISSION OF THE ARCHITECT BEFORE DOING ANY GUTTING. ALL HOLES SHALL BE CUT A5 SMALL AS POSSIBLE. CONTRACTOR SHALL PATCH WALLS, FLOORS, ETC. A5 REQUIRED BY WORK UNDER THIS SECTION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. 16A 2-4 ROUGH -IN. COORDINATE WITHOUT DELAY ALL ROUGHING -IN WITH GENERAL CONSTRUCTION. ALL CONDUIT ROUGH -IN SHALL BE CONGEALED EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE SHOWN. I6A 2-5 CONDUIT. ALL CONDUIT SHALL BE RUN CONGEALED EXCEPT WHERE OTHERWISE NOTED. ALL CONDUIT RUN UNDERGROUND, EXPOSED TO WEATHER, OR OTHER HAZARDOUS CONDITIONS SHALL BE RIGID. ALL OTHER CONDUIT MAY BE THIN-WALL WHERE APPROVED BY LOCAL CODE. AT CONTRACTOR'S OPTION, PVC CONDUIT (WITH GROUND WIRE) MAY BE USED WHERE PERMITTED BY CODE. FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO ANY DEVICE WHICH WOULD OTHERWISE TRANSMIT MOTION, VIBRATION OR NOISE, SHALL BE IN FLEXIBLE METAL CONDUIT. WHERE FLEXIBLE METAL CONDUIT 15 EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, LIQUID -TIGHT FLEXIBLE METAL CONDUIT SHALL BE USED. ALL FLEXIBLE METAL CONDUIT SHALL BE PROVIDED WITH AN INSULATED GROUND WIRE. I6A 2-6 CONDUIT INSTALLATION. A. ALL WIRING SHALL BE RUN IN CONDUIT OR BE TYPE MG GABLE WHERE SPECIFIED A5 ACCEPTABLE. MAXIMUM LENGTH OF RUN FOR MG GABLE 15 6'-O". B. CONDUIT SHALL BE INSTALLED CONCEALED ABOVE SUSPENDED CEILINGS OR CONGEALED IN WALLS OR FLOORS WHEREVER POSSIBLE. FOR MULTISTORY BUILDINGS, CONDUIT SHALL 5E INSTALLED CONGEALED IN CEILING PLENUM OF SPACE BELOW AND SHALL NOT INTERFERE WITH EXISTING TENANT PLENUM MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS. RUN PARALLEL TO BUILDING LINES. G. CONDUIT SHALL BE INSTALLED TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT. CONDUIT SHALL BE INSTALLED TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS, REINFORCING STEEL, ETC. CONDUIT SET IN FORMS FOR CONCRETE STRUCTURE SHALL BE INSTALLED 114 SUCH A MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. EXCEPT WHERE APPROVED IN WRITING BY THE ARCHITECT, NO CONDUIT SHALL BE RUN IN A CONCRETE SLAB. CONDUIT SHALL BE LOCATED IN GRANULAR FILL BELOW SLABS ON GRADE OR IN PLENUM SPADE. D. CONDUITS SHALL BE INSTALLED CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN THE EQUIVALENT OF FOUR 40 DEGREE BENDS BETWEEN CONNECTIONS. BENDS SHALL BE SMOOTH AND EVEN A1417 SHALL BE MADE WITHOUT FLATTENING CONDUIT OR FLAKING ENAMEL. RADIUS OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE CORRESPONDING TRADE ELBOW. LONG RADIUS ELBOWS SHALL BE USED WHERE NECESSARY. E. CONDUITS SHALL BE SECURELY FASTENED IN PLAGE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. SINGLE CONDUITS FOR FEEDERS SHALL BE HUNG WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND 'TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. GROUPS OF HORIZONTAL FEEDER CONDUITS SHALL 5E CLAMPED TO UNISTRIJT STEEL CHANNELS AND SUSPENDED FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE._ VERTICAL FEEDER CONDUITS SHALL BE SECURELY CLAMPED TO STRUGTURAL STEEL MEMBERS ATTACHED TO STRUCTURE. GABLE CLAMPS SHALL BE INSTALLED FOR SUPPORT OF VERTICAL FEEDERS WHERE REQUIRED. CONDUIT, SUPPORTS SHALL BE ADDED WITHIN 12" AT ONE E117 OF ALL BENDS. CONDUIT SHALL NOT BE SUPPORTED FROM SUSPENDED CEILING COMPONENTS, DUCT WORK OR PIPING. F. CONDUIT ENDS SHALL BE REAMED BEFORE INSTALLATION AND ALL CONDUIT SHALL BE THOROUGHLY GLEANED BEFORE INSTALLATION AND KEPT GLEAN AFTER INSTALLATION. OPENINGS AND BOXES SHALL BE PLUGGED OR COVERED AS REQUIRED TO KEEP CONDUIT GLEAN DURING CONSTRUCTION AND ALL CONDUIT SHALL BE FISHED GLEAR OF OBSTRUCTIONS BEFORE THE PULLING OF WIRES. ALL CONDUIT SHALL BE OF AMPLE SIZE FOR PULLING OF WIRE AND SHALL NOT 135 SMALLER THAN CODE REQUIREMENTS AND NOT LESS THAN 1/2" IN SIZE. G. ALL ELECTRICAL WORK SHALL BE PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. ANY WORK DAMAGED OR MOVED OUT OF LINE AFTER ROUGHING -IN SHALL BE REPAIRED TO MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER. H. CONDUIT TERMINATIONS AT PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION 5OXE5 SHALL BE ALIGNED AND INSTALLED TRUE AND PLUMB. I. INSTALL APPROVED EXPANSION FITTINGS WHERE CONDUIT OR EMT PASSES THROUGH EXPANSION JOINTS. J. INSTALL A PULL WIRE IN EACH EMPTY CONDUIT WHICH 15 LEFT BY THE CONTRACTOR FOR INSTALLATION OP WIRES OR GABLES BY OTHERS. K. MAKE ALL JOINTS AND CONNECTIONS IN A MANNER WHICH WILL INSURE MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY. L. THRU-WIRING OF LIGHT FIXTURES 15 NOT PERMITTED. M. METALLIC CONDUIT IN DIRECT CONTACT WITH EARTH SHALL BE COATED WITH AN ASPHALT BASE PAINT U.L. LISTED FOR THIS APPLICATION. I6A 2-1 BUSHINGS AND LOGKNUTS. WHERE CONDUITS ENTER BOXES, THEY SHALL BE RIGIDLY CLAMPED TO THE BOX BY A BUSHING ON THE INSIDE AND A LOGKNUT ON THE OUTSIDE, AND CONDUIT SHALL ENTER THE BOX SQUARELY. BUSHINGS AND LOGKNUTS SHALL BE MADE OF GALVANIZED MALLEABLE IRON AND SHALL HAVE SHARP, GLEAN -GUT THREADS. WHERE THIN-WALL CONDUIT ENTERS BOX, PROVIDE APPROVED E.M.T. CONNECTORS. U5E INSULATED GROUNDING BUSHINGS WHEREVER CONNECTION 15 SUBJECT TO VIBRATION OR MOISTURE. I6A 2-8 WIRE. ALL WIRE SHALL HAVE COPPER CONDUCTORS, WITH UL. LABEL, AND 600 VOLT INSULATION. ALL WIRE SHALL BE RUN IN CONDUIT, INCLUDING LOW VOLTAGE WIRING. SERVICE ENTRANCE GABLE SHALL 135 TYPE USE, THHN OR XHHN WITH STRANDED CONDUCTORS. ALL FEEDER AND BRANCH CIRCUITS WIRE #8 AWG AND LARGER SHALL BE TYPE THWN OR XHHW, BOTH WITH STRANDED CONDUCTORS. ALL WIRE #I0 AWG AND SMALLER SHALL BE TYPE THIN (YET OR DAMP LOCATIONS, OR IN CONDUIT BELOW GRADE OR SLAB) OR THHN (DRY LOCATIONS ONLY AND ABOVE GRADE), BOTH WITH SOLID CONDUCTORS. WIRE WITHIN FLUORESCENT FIXTURE CHANNELS SHALL BE TYPE THHN. ALL BRANCH CIRCUIT WIRING SHALL BE NOT SMALLER THAN #12 AWG WIRE. IF NO WIRE SIZE 15 INDICATED 014 THE PLANS FOR A BRANCH CIRCUIT, PROVIDE #12AWG WIRE AND A 20A CIRCUIT BREAKER. CONTROL WIRING SHALL HAVE 600V INSULATION AND BE OF THE PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO ACCOMPLISHED SPECIFIED FUNCTION. CONSULTANTS 12035 COLWICK Project Management • Design SAN ANTONIO, TX 78216 I6A 2-q WIRING INSTALLATION. A. ALL WIRING, INCLUDING LOW VOLTAGE, SHALL BE INSTALLED IN APPROVED RACEWAY AND ENCLOSURES. B. SUPPORT ALL WIRE AND GABLES 114 VERTICAL INSTALLATIONS AS REQUIRED BY 0017S BY INSTALLING GABLE SUPPORTERS OR PLUG -TYPE CONDUIT RISER SUPPORTS. G. ALL WIRE AND GABLE IN CONDUIT SHALL BE CONTINUOUS WITHOUT TAPS OR SPLICES. ALL SPLICES OR TAPS SHALL OCCUR IN APPROVED BOXES AND ENCLOSURES AND SHALL BE KEPT TO 11H5 MINIMUM REQUIRED, AND SHALL BE MADE UP OF APPROVED SOLDERLES5 CONNECTORS. ALL SPLICES, TAPS, AND JOINTS SHALL BE INSULATED AS REQUIRED BY CODE. D. ALL MATERIALS USED TO TERMINATE, SPLICE OR TAP CONDUCTORS SHALL BE DESIGNED FOR, PROPERLY SIZED FOR, AND U.L. LISTED FOR THE SPECIFIC APPLICATION AND CONDUCTORS INVOLVED, AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, USING THE MANUFACTURER'S RECOMMENDED TOOLS. E. WHERE WIRE 15 INDICATED TO BE INSTALLED, BUT THE CONNECTION 15 INDICATED "FUTURE" OR BY OTHERS", CONTRACTOR SHALL LEAVE A MINIMUM OF 3 FEET OF "PIGTAIL" AT THE BOX, TAPE THE ENDS OF T145 CONDUCTORS, AND COVER THE BOX. F. THE NUMBER OF CONDUCTORS IN A SPECIFIC CONDUIT RUN ARE INDICATED WITH GROSS LINES ON EACH "CONDUIT RUN" ON THE DRAWINGS. IN GENERAL, DIRECTION OF BRANCH CIRCUIT "HOME RUN" ROUTING 15 INDICATED 014 THE DRAWINGS, COMPLETE WITH CIRCUIT NUMBERS AND PANELBOARD DESIGNATION. THIS CONTRACTOR SHALL CONTINUE ALL SUCH "HOME RUN" WIRING TO THE DESIGNATED PANELBOARD, AS THOUGH "CONDUIT RUNS" WERE INDICATED 114 THEIR ENTIRETY. 6. CONDUCTORS SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH NEC COLOR CODE SYSTEM AND IN THE TABLE BELOW. IN LARGER WIRE SIZES WHERE PROPERLY COLORED INSULATION 15 140T AVAILABLE, THE CONTRACTOR SHALL USE VINYL PLASTIC ELECTRICAL TAPE OF THE APPROPRIATE COLOR AROUND EACH GABLE AT ALL TERMINATION POINTS, JUNCTION AND PULL BOXES. SYSTEM VOLTAGE 208Y/120 NEUTRAL -WHITE PHASE A OR LI -BLACK PHASE B OR L2 -RED PHASE G OR L3 -BLUE GROUND -GREEN 480Y/2T7 NEUTRAL - WHITE WITH TRACER OR GRAY PHASEAORLI - BROWN PHASE B OR L2 -ORANGE PHASE 0 OR L3 -YELLOW GROUND -GREEN 1111+ TRAGER 14. ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL WIRING SHALL BE PROPERLY NUMBERED FOR IDENTIFICATION WITH VINYL STICK -ON MARKERS OR EQUIVALENT. I. ALL RECEPTACLE AND NON -LIGHTING EQUIPMENT BRANCH CIRCUITS SHALL HAVE AN EQUIPMENT GROUND CONDUCTOR INSTALLED IN THE BRANCH CIRCUIT RACEWAY, SIZED IN ACCORDANCE WITH NEC TABLE 250-45. J. VOLTAGE DROP IN BRANCH GIRGUITS SHALL NOT EXCEED 2%. - 16A 2-10 JUNCTION BOXES. PULL BOXES CABINETS AND NIREWAYS. PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS WHEREVER NECESSARY FOR PROPER INSTALLATION OF VARIOUS ELECTRICAL SYSTEMS ACCORDING TO THE NATIONAL ELECTRICAL 0017E AND WHERE INDICATED ON THE DRAWINGS. SIZE A5 REQUIRED FOR THE SPECIFIC FUNCTION OR A5 REQUIRED BY THE NATIONAL ELECTRICAL CODE, WHICHEVER 15 LARGEST. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED. I6A 2-11 OUTLET BOXES. ALL OUTLETS INCLUDING LIGHT, SWITCH, RECEPTACLE, AND SIMILAR OUTLETS, SHALL BE NATIONAL ELECTRICAL, APPLETON, STEEL CITY, RAGO OR APPROVED EQUAL GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE PURPOSE THEY SERVE AND THE SPACE THEY OCCUPY. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR A5 REQUIRED BY THE NATIONAL ELECTRICAL CODE, WHICHEVER 15 LARGEST. ALL OUTLET BOXES SHALL BE SET IN WALLS, COLUMNS, FLOORS, OR. CEILINGS 50 AS TO BE FLUSH WITH THE FINISHED SURFACE AND BE ACCURATELY SET AND RIGIDLY SECURED IN POSITION. PROVIDE PLASTER RINGS, EXTENSION R1165 AND MASONRY RINGS AS REQUIRED FOR FLUSH MOUNTING. I6A 2-12 OUTLET LOCATIONS. OUTLETS ARE ONLY APPROXIMATELY LOCATED OH THE SMALL SCALE PLANS, AND GREAT CARE MUST BE USED 114 THE ACTUAL LOCATION BY CONSULTING THE VARIOUS LARGE SCALE DETAILED DRAWINGS USED BY OTHER CONTRACTORS, AND BY SECURING DEFINITE LOCATIONS FROM THE ARCHITECT. THE HEIGHT OF THE CENTER OF OUTLETS ABOVE 1145 FINISHED FLOOR, IF NOT OTHERWISE SPECIFIED OR SHOWN 01 1145 DRAWINGS, SHALL GENERALLY BE AS FOLLOWS: SWITCH OUTLETS 48" ABOVE FLOOR TO TOP OF OUTLET WALL RECEPTACLES 15" ABOVE FLOOR TO BOTTOM OF OUTLET DEVICES ABOVE COUNTERS 10" ABOVE COUNTER TO TOP OF OUTLET I6A 2-13 WIRING DEVICES. FURNISH AND INSTALL THE FOLLOWING OUTLETS AND SWITCHES WHERE SHOWN OR REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OF ELECTRICAL EQUIPMENT MAY BE MADE BY THIS CONTRACTOR TO COMPLY WITH STRUCTURAL AND BUILDING REQUIREMENTS AS DETERMINED IN THE COURSE OF CONSTRUCTION. ALL OUTLETS AND SWITCHES MUST BE OF THE SAME MANUFACTURER AND NOT MIXED 014 THE PROJECT. COLOR OF TOGGLES AND RECEPTACLES SHALL BE A5 REQUESTED BY THE ARCHITECT: DUPLEX RECEPTACLE: PASS 8 SEYMOUR #5352 SINGLE POLE SWITCH: PASS 8 SEYMOUR #20AGI THREE-WAY SWITCH: PASS 8 SEYMOUR 4120AC3 OCCUPANCY SENSOR SWITCH: WATT STOPPER #115I20/2T1 IVORY MOMENTARY SWITCH: PA55 +1 SEYMOUR #1221 (CONTROLS CONTACTOR) PILOT LIGHT SWITCH: PASS +E SEYMOUR #20AGI-RPL KEY SWITCH: PASS * SEYMOUR #20A01 -L ISOLATED GROUND RECEPTACLE: PASS 4 SEYMOUR #168300 GFGI DUPLEX RECEPTACLE: PASS 4 SEYMOUR #2011 WALL -130X DIMMER SWITCH: LUTRON ARIADNI AY -IOP -IV (10004) IVORY SAFETY RECEPTACLE: PASS 5 SEYMOUR #56-62 (NEMA 5-I5R) DUPLEX RECEPTACLE BRYANT #GBR20 (NEMAS-20R) QUADPLEX RECEPTACLE BRYANT #21254-I (NEMA5-20R) CASHIER STATION 3-6ANG FLOORBOX: HUBBELL #84333* 3 -GANG CARPET FLANGE: HUBBELL #583085 * DUPLEX FLAP: HUBBELL #53825 * GAT 5 JACKS (4): HUBBELL #HBLSEBK * GAT 5 RECEPTACLE: HUBBELL #DJI06BK * * NOTE: FOR USE IN SLAB CUT/TRENCHING APPLICATIONS (REQUIRES 18" MINIMUM WIDE TRENCH. ORIENT BOX PARALLEL TO TRENCH TO ALLOW FOR CONDUIT SWEEP.) CASHIER STATION CORE DRILL FLOOR BOX: HUBBELL #PT4X6Y20 ** GAT 5/RECEPTACLES: HUBBELL #PT4XGAT5 ** ** NOTE: FOR USE 114 CORE DRILL APPLICATIONS. (REQUIRES 3" DIAMETER CORE) IN SALES AREA, DEVICES INSTALLED IN MILLWORK SHALL BE WHITE. ALL OTHER AREA'S DEVICES TO BE IVORY. VERIFY DEVICE DOLOR WITH ARCHITECT PRIOR TO INSTALLATION. ISOLATED GROUND RECEPTACLES TO BE WHITE. EQUIVALENT HUBBELL, LEVITON, AND COOPER WIRING DEVICES WILL BE ACCEPTABLE. OTHER DEVICES SHOWN ON THE PLANS BUT NOT CAI LFP OUT ABOVE SHALL BE OF THE SAME CONSTRUCTION QUALITY AS DEFINED 13Y THE MODEL NUMBERS SHOWN. DUPLEX RECEPTACLES, INSTAI 1 Fn VERTICALLY, SHALL BE INSTALLED WITH THE GROUNDING TERMINAL "UP". I6A 2-14 SWITCH AND OUTLET COVER PLATES. ALL SWITCH AND OUTLET PLATES SHALL BE P*5 IVORY IN STORAGE ROOM, TOILET AND CLOSET; IVORY WHERE INSTALLED IN SALES AREA WALLS WITH COVERINGS; WHITE WHERE INSTALLED 114 SALES AREA CEILING AND 114 MILLWORK. VERIFY DESIRED MATERIAL WITH ARCHITECT BEFORE INSTALLATION. SWITCH PLATES IN UNFINISHED ROOMS AND SPACES SHALL BE STAMPED STEEL PLATES, CADMIUM PLATED. GROUPS OF SWITCHES SHALL BE UNDER ONE GANG -PLATE, USUALLY .MOUNTED HORIZONTALLY; WHERE REQUIRED BY DETAILS, VERTICAL MOUNTING SHALL BE USED INSTEAD. PLATES SHALL BE SET PLUMB, PARALLEL, AND SHALL FINISH FLUSH WITH 1145 WALL. IaAMIN index date,: Ill^;Aa,,, ; rvx12''u liun : 5 . 6 . 13 ISSUED TO CLIENT FOR FINAL REVIEW 5 . 1 . 13 1551)517 TO LANDLORD FOR FINAL REVIEW 5 . 10 . 13 ISSUED FOR 510 * PERMIT .IL 16A 2-15 WEATHERPROOF DOVER PLATES. WEATHERPROOF OUTLETS TO BE GROUND FAULT PROTECTED. PROVIDE INTERMATIG #11PI010 WEATHERPROOF DOVER. 11H5 COVER SHALL BE MOLDED FROM A CLEAR 141614 IMPACT ULTRAVIOLET STABILIZED POLYCARBONATE MATERIAL FOR EASY VERIFICATION THAT CORDS ARE PLUGGED IN AND THAT THE GFGI IS FUNCTIONING I6A 2-16 FIRESTOPPING OF FLOOR AND WALL PENETRATIONS. T14I5 CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH FIRE RATED FLOOR AND WALL ASSEMBLIES 114 ACCORDANCE WITH NEPA 001755 AND UL WALL CONSTRUCTION TYPES. THE SEALING SYSTEM MUST BE CAPABLE OF PASSING A THREE HOUR TEST, PER ASTM E-314 (UL 1414). PENETRATION SEALING SYSTEM SHALL 5E, AT A MINIMUM, 3M BRAND 1404 (GP -25 CAULK, OR 303 PUTTY), OR APPROVED EQUAL, AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 16A 2-11 FLASHING AND PITCH POGKETS. FLASH AND GOUNTERFLASH ALL OPENINGS THROUGH ROOF, AND/OR PROVIDE PITCH POCKETS AS REQUIRED. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE TERMINATION OF THE WORK. 16A 2-18 CONCRETE BASES. CONTRACTOR SHALL FURNISH CONCRETE BASES FOR 1415 EQUIPMENT WHERE INDICATED ON THE DRAWINGS. 16A 2-14 ACCESS DOORS. PROVIDE ACCESS DOORS IN CEILINGS, WALLS, ETC. WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO WORK INSTALLED UNDER THIS SECTION, MILGOR OR EQUIVALENT. 16A 2-20 EQUIPMENT IDENTIFICATION. THIS CONTRACTOR SHALL FURNISH AND INSTALL EQUIPMENT IDENTIFICATION NAMEPLATES ON ALL PANELBOARDS, SNITCHES, STARTERS, DIMMERS, ETC., INCLUDING SWITCHES IN DISTRIBUTION PANELS. NAMEPLATES SHALL BE ENGRAVED PHENOLIC PLASTIC, AND SHALL BE FIRMLY ATTACHED TO THE EQUIPMENT. NAMEPLATES SHALL CLEARLY IDENTIFY EACH ITEM AND WHAT IT CONTROLS. 16A3 ELECTRICAL SERVICE AND GROUNDING I6A 3-1 ELECTRICAL SERVICE. SEE DRAWINGS FOR TYPE, SIZE, VOLTAGE, PHASE, ETC. I6A 3-2 CONNECTION TO SERVING UTILITIES. SEE DRAWINGS FOR INFORMATION REGARDING THE ELECTRICAL CONNECTION TO THE EXISTING LANDLORD'S/OWNER'S ELECTRICAL SERVICE. VERIFY THE SIZE, LOCATION, VOLTAGE, ETC., OF THE EXISTING DISTRIBUTION EQUIPMENT PRIOR TO CONSTRUCTION. PROVIDE ALL NECESSARY EQUIPMENT FOR TENANT'S CONNECTION TO THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM. 16A 3-3 GROUNDING. THE ELECTRICAL SERVICE, ALL TRANSFORMERS, CONDUCTORS, CONDUITS, MOTOR FRAMES, ETC. IN THIS CONTRACT 11141014 REQUIRE .GROUNDING SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED BY THIS CONTRACTOR 114 A THOROUGH AND EFFICIENT MANNER IN CONFORMANCE TO THE NATIONAL ELECTRICAL CODE. 16A4 DISTRIBUTION AND CONTROL EQUIPMENT ISA 4-1 CIRCUIT BREAKERS 1N EXISTING PANELBOARDS. NEW CIRCUIT BREAKERS REQUIRED TO BE INSTALLED IN EXISTING PANELBOARDS SHALL BE OF THE SAME MANUFACTURER, TYPE AND HAVE THE SAME AIG RATINGS AS THE EXISTING PANELBOARD CIRCUIT BREAKERS. ISA 4-2 PANELBOARDS. INSTALL PANELBOARDS FURNISHED 5Y OWNER A5 ,SGHEDULED AND LOCATED ON DRAWINGS. EACH PANEL SHALL CONTAIN A TYPEWRITTEN CARD DIRECTORY INDICATING EXACTLY WHAT EACH CIRCUIT CONTROLS. PANELBOARD SUPPLIED COMPLETE WITH BOLT ON THERMAL MAGNETIC, MOLDED CASE CIRCUIT BREAKERS ASSEMBLED IN A DEAD FRONT FINISHED CABINET, FULLY RATED AND WITH THE INTEGRATED SHORT CIRCUIT CURRENT RATINGS INDICATED ON THE DRAWINGS. PLUG IN TYPE BREAKERS WILL NOT BE ACCEPTABLE. ALL TWO AND THREE POLE BREAKERS: COMMON TRIP TYPE. BREAKERS USED A5 SWITCHES FOR 120V OR 211/ LIGHTING CIRCUITS: APPROVED FOR THE PURPOSE AND MARKED "514)". 16A 4-3 DISCONNECT SWITCHES. CONTRACTOR SHALL FURNISH AND INSTALL SQUARE D, SEIMENS, CUTLER HAMMER, OR GENERAL ELECTRIC FUSED OR NON-FUSED (AS NOTED OR REQUIRED) NEMA HEAVY DUTY EXTERNALLY OPERATED SAI -t 1 Y SWITCHES AND MOTOR STARTERS WHERE NOT FURNISHED WITH THE STARTING EQUIPMENT, AND AT ALL OTHER POINTS REQUIRED 5Y CODE. FUSE HOLDERS SHALL HAVE GLASS R REJECTION FEATURE. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED IN. ISA 4-4 FUSES. PROVIDE EACH CIRCUIT AND SET OF FUSE CLIPS THROUGHOUT THE WORK WITH BUSSMANN, FERRAZ SHAWMUT, OR LITTLEFUSE FUSES, SIZES AND TYPES AS REQUIRED OR INDICATED. ALL FUSES LARGER THAN 600A: UL GLASS L, SIMILAR TO TYPE KRP-G BUSSMANN LOW PEAK OR EQUAL. FUSES USED TO PROTECT MOTORS: UL GLASS RKS, BUSSMANN FUSETRON OR EQUAL. FUSES USED TO PROTECT ALL OTHER ELECTRICAL EQUIPMENT: UL GLASS RKI, DUAL ELEMENT, BUSSMANN LPS/LPN OR EQUAL. ALL FUSED DEVICES SHALL BE LABELED A5 TO TYPE AND SIZE OF FUSE REQUIRED. ISA 4-5 SPARE FUSES. FURNISH THREE SPARE FUSES OF EACH SIZE AND TYPE USED ON THE PROJECT (EXCEPT MAIN SWITCH FUSES), NEATLY CONTAINED IN A PROPERLY LABELED CABINET. ISA 4-6 HAGR CIRCUIT BREAKERS. PROVIDE AN HAGR CIRCUIT BREAKER FOR EACH CIRCUIT CONNECTED TO HVAC. OR REFRIGERATION EQUIPMENT MOTOR LOAD. HAGR CIRCUIT BREAKERS INSTALLED IN PANEL BOARDS SHALL BE OF THE SAME MANUFACTURER, TYPE, AND AIG RATINGS A5 THE EXISTING AND/OR NEW PANEL BOARD CIRCUIT BREAKERS. ISA 4-1 DRY -TYPE TRANSFORMERS. INSTALL TRANSFORMERS FURNISHED BY YGG. MOUNT ON VIBRATION ISOLATION PADS WITH A .25" STATIC DEFLECTION. CONDUIT CONNECTIONS TO TRANSFORMERS SHALL BE MADE WITH FLEXIBLE CONDUIT WITH AT LEAST 6" OF SLACK 114 ALL DIRECTIONS. 16A5 LIGHT FIXTURES. LAMPS AND BALLASTS 16A 5-1 LIGHT FIXTURE LOCATIONS. LIGHT FIXTURES SHOWN ON THE ELECTRICAL DRAWINGS REPRESENT GENERAL ARRANGEMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR MORE EXACT LOCATIONS. COORDINATE LOCATION WITH ALL OTHER TRADES BEFORE INSTALLATION TO AVOID CONFLICTS. LIGHT FIXTURES LOCATIONS IN MECHANICAL ROOMS SHALL BE COORDINATED WITH FINAL INSTALLED PIPING AND DUCTWORK LAYOUTS. 16A 5-2 LIGHT FIXTURES. PROVIDE LIGHT FIXTURES NOT FURNISHED BY THE OWNER A5 SCHEDULED ON DRAWINGS. THIS SHALL INCLUDE ALL LAMPS, MATERIAL AND LABOR TO SECURELY HANG FIXTURES, GLEAN THEM AND MAKE THEM COMPLETELY READY FOR USE. ALL LIGHT FIXTURES SHALL INCLUDE ALL NECESSARY ACCESSORIES REQUIRED. LIGHT FIXTURE MODELS SCHEDULED 014 THE DRAWINGS ARE TO 514011 THE MANUFACTURER, GRADE AND STYLE OF FIXTURES REQUIRED ONLY. PROVIDE ALL HANGERS, SUPPORTS, AND MISCELLANEOUS HARDWARE REQUIRED TO INSTALL LIGHT FIXTURES. PROVIDE PROPER TRIM TO FIT EACH CEILING CONDITION ENCOUNTERED. PROVIDE ADDITIONAL TIE WIRES CONNECTED TO STRUCTURE TO CONFORM TO UB0 41-18 SEISMIC REQUIREMENTS WHERE REQUIRED. INSTALL ALL FIXTURES AND LAMPS FURNISHED BY THE OWNER. AIM ALL TRACK LIGHTING AS DIRECTED BY THE OWNER. THE OWNER WILL PROVIDE LAMPS POR OWNER FURNISHED FIXTURES ONLY. ISA 5-3 LAMPS. LAMPS FOR ALL LIGHTING FIXTURES NOT FURNISHED BY THE OWNER SHALL BE PROVIDED AND INSTALLED BY THIS CONTRACTOR. PROVIDE LAMPS INDICATED ON 115 DRAWINGS, OR IF NOT INDICATED, AS RECOMMENDED BY THE FIXTURE MANUFACTURER. 114 ALL GASES LAMPS SHALL BE COMPATIBLE WITH SPECIFIED FIXTURE. LAMPS SHALL BE MANUFACTURED BY GENERAL ELECTRIC, OSRAM/SYLVANIA, PHILLIPS, OR VENTURE. ALL FLUORESCENT LAMPS SHALL BE COOL WHITE, UNLESS NOTED OR DIRECTED OTHERWISE. ALL FLUORESCENT LAMPS IN BAGKROOM AREAS SHALL BE 3500 DEGREE KELVIN AND A COLOR RENDERING INDEX OF 15. INCANDESCENT LAMPS SHALL BE TYPE AND WATTAGE AS SHOWN ON THE DRAWINGS AND SHALL BE 130 VOLT UNLESS OTHERWISE SCHEDULED OR SPECIFIED. ISA 5-4 BALLASTS. ALL FLUORESCENT BALLASTS: SHALL BE THERMALLY PROTECTED AGAINST OVERHEATING; SHALL BE ETL-GBM, GLASS P TO MIS=T ALL REQUIREMENTS OF SECTION 410-13 (E) OF THE NEC AS A MINIMUM; SHALL COMPLY 111TH THE NATIONAL BALLAST ENERGY LAW; SHALL HAVE A MINIMUM 40% POWER FACTOR; SOUND LEVELS SHALL NOT EXCEED GLASS A AMBIENT NOISE LEVELS; AND SHALL BE LOW HEAT TYPE. Electrical Specifications , 5. 10. 13 drawn clg c I a AS NOTED INDOOR FLUORESCENT BALLASTS: SHALL BE ELECTRONIC TYPE SUITABLE FOR OPERATION OF T8 LAMPS; SHALL HAVE A TOTAL HARMONIC DISTORTION LESS THAN 20%; SHALL HAVE A FREQUENCY OF OPERATION OF 20 KHZ OR GREATER AND OPERATE WITH NO VISIBLE FLICKER; SHALL BE ADVANCETAND LINE RELNEL SERIESIOR EQUAL OF NTS A5 MAGNETEK IN /MOTOROLA OR OSRAM. CATEGORY A; AND SHALL COMPACT FLUORESCENT BALLASTS: SHALL BE THERMALLY PROTECTED AGAINST OVERHEATING; SHALL BE GLASS P; SHALL HAVE A MINIMUM 4096 POWER FACTOR; SOUND LEVELS SHALL NOT EXCEED GLASS A AMBIENT NOISE LEVELS; AND SHALL BE L011 HEAT TYPE. ALL BALLASTS SHALL BE BY ADVANCE. BALLASTS FOR 36H through 55W LAMPS SHALL BE MARK V ELECTRONIC TYPE. I6A6 MISCELLANEOUS ELECTRICAL ISA 6-1 WIRING OF MECHANICAL EQUIPMENT. FURNISH AND INSTALL ALL POWER WIRING, AND ALL CONTROL AND INTERLOCK WIRING OF ALL UNITS, PUMPS, FANS, WATER HEATERS, DOOR OPERATORS, ETC. CONNECT PER. MANUFACTURER'S WIRING DIAGRAMS. FURNISH AND INSTALL ALL DISCONNECT SWITCHES AS REQUIRED. AFTER INSTALLATION OF THE CONTROL INTERLOCK WIRING, THE CONTRACTOR SHALL VERIFY THAT EACH MOTOR LOAD HAS THE CORRECT PHASE ROTATION. THIS CONTRACTOR SHALL VERIFY THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL EQUIPMENT FROM THE EQUIPMENT NAMEPLATE; ELECTRICAL INSTALLATION SHALL BE BASED ON ACTUAL REQUIRED AMPERAGES, WHICH MAY VARY SOMEWHAT FROM THE WIRE AND EQUIPMENT SIZES 510111 ON THE DRAWINGS. PROPERLY SIZED ELECTRICAL WIRING AND EQUIPMENT SHALL BE FURNISHED WITHOUT EXTRA COST TO THE CONTRACT. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CHANGES TO BE MADE 114 THE ELECTRICAL INSTALLATION DUE TO EQUIPMENT VARIANCES 50 THAT THE IMPACT ON FEEDERS, PANELS, FUSE AND BREAKER SIZES GAN BE CHECKED PRIOR TO THE INSTALLATION. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH 11-15 MEGHANIGAL, REFRIGERATION AND PLUMBING CONTRACTORS TO VERIFY THE ACTUAL WIRE SIZING AMPS AND CORRECT SIZES OF ALL OVERLOAD HEATERS FOR ALL EQUIPMENT. ISA 6-2 WIRING OF THERMOSJAT5 AND TEMPERATURE CONTROLS. FURNISH AND INSTALL ALL POWER WIRING, AND ALL CONTROL AND INTERLOCK WIRING OF ALL THERMOSTATS AND TEMPERATURE CONTROL DEVICES INCLUDING NIGHTSTATS, TIME SNITCHES AND OVERRIDE TIMERS, ETC., NOT INSTALLED UNDER PREVIOUS CONTRACT AND SHOWN ON MECHANICAL DRAWINGS SUBMITTED UNDER THIS CONTRACT. SEE MECHANICAL DRAWINGS FOR LOCATIONS AND TEMPERATURE CONTROL DIAGRAMS. ISA 6-3 TELEPHONE SYSTEM PROVISIONS. PROVIDE AND INSTALL INCOMING TELEPHONE SERVICE CONDUIT A5 SHOWN ON DRAWINGS OR A5 REQUIRED 5Y TELEPHONE COMPANY. PROVIDE AND INSTALL PLYWOOD BOARD 114 EQUIPMENT CLOSET FOR TELEPHONE, SECURITY AND AUDIOVISUAL EQUIPMENT AT LOCATION A5 SHOWN ON DRAWINGS. PROVIDE AND INSTALL FLUSH MOUNTED TELEPHONE OUTLET BOXES WITH 3/4" CONDUIT CONGEALED ABOVE ACCESSIBLE CEILING SPADE AT LOCATIONS A5 SHOWN ON DRAWINGS. TELEPHONE COMPANY TO INSTALL TELEPHONE JACKS AND WIRING. ISA 6-4 DATA. TV AND SECURITY SYSTEM PROVISIONS. TELEPHONE, DATA AND SECURITY CONDUITS SHALL 5E A MINIMUM OF T110 GANG BOX WITH SINGLE GANG PLASTER RING. PROVIDE BUSHED HOLE OR GOVERPLATE WITH COAXIAL OPENINGS AS DIRECTED BY OWNER. PROVIDE CONDUIT AND PULLWIRE FOR COMPUTER/DATA EQUIPMENT A5 DIRECTED ON DRAWINGS (WIRE, JACKS AND FINAL CONNECTION BY OTHERS). PROVIDE CONDUIT AND PULLWIRE FOR SECURITY EQUIPMENT (EQUIPMENT SUPPLIED AND INSTALLED BY OTHERS). ISA 6-5 CONTACTORS. INSTALL OWNER FURNISHED MECHANICALLY HELD CONTACTOR DESIGNED FOR TUNGSTEN AND BALLAST LIGHTING LOADS. I6A8 EXISTING EQUIPMENT REUSE AND REMOVAL. THIS CONTRACTOR SHALL REMOVE ALL EXISTING WIRING, FIXTURES, EXPOSED CONDUITS AND OTHER FI FGTRIGAL INSTALLATIONS NOT REUSED PRIOR TO TERMINATION OF THE WORK. EXISTING CONDUITS AND RACEWAYS MAY BE REUSED IF THEIR POINTS OF TERMINATIONS ARE SUITABLE; IF THEY ARE CLEAN INSIDE WITH NO EVIDENCE OF RUST OR BURRS; IF FREE FROM CRACKS, FLATTENED SECTIONS OR SHARP BENDS; AND IF SUITABLY LOCATED TO AVOID CONFLICTS WITH OTHER TRADES OR INSTALLATIONS. ALL EXISTING CONDUITS REUSED UNDER THIS CONTRACT SHALL BE CAREFULLY "FISHED" TO REMOVE ALL DEBRIS AND OBSTRUCTIONS, AND SWABBED UNTIL ALL MOISTURE 15 REMOVED. IT SHALL BE THE RESPONSIBILITY OF T14I5 CONTRACTOR TO CUT, PATCH, AND REPAIR WHERE REQUIRED FOR NEW FI FCTRIGAL INSTALLATIONS, AND HE SHALL PATCH AND REPAIR ANY SURFACE DAMAGE RESULTING FROM 14I5 WORK. CONDUITS STUBBED ABOVE THE FLOOR AND NOT USED AT THE TERMINATION OF THE WORK SHALL BE GUT FLUSH WITH THE FLOOR AND PLUGGED AT BOTH ENDS. ALL EXISTING F1 FGTRIGAL SYSTEMS REQUIRED TO BE IN OPERATION AT THE TERMINATION OF THE CONTRACT SHALL BE RELOCATED, IF REQUIRED, A5 A RESULT OF WORK INCLUDED UNDER THIS CONTRACT, EVEN IF NOT SPECIFICALLY INDICATED IN THE DRAWINGS OR SPECIFICATIONS. REFER TO LANDLORD'S MECHANICAL/ELECTRICAL CRITERIA FOR ADDITIONAL SCOPE OF WORK TO BE INCLUDED UNDER THIS CONTRACT. REVIEWED .I -Rh COMPLIANCE WITH NFPA70-NEC JUN 0 5 2013 City of Tukwila •. 13t.)1t,piNg.piyisrls ELIC #644 Westfield South Center Seattle, WA #204 a" , It,: 1,647 pi IM`s ' 13064 III''w5` 52Z RECEIVED CITY OF TUKWILA MAY 302013 PERMIT CENTER JIMMY L. PS ERS STATE OF WASHINGTON