Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL13-0567 - FEDEX OFFICE - TENANT IMPROVEMENT
FEDEX OFFICE 116 ANDOEVR PK E EL1 3-0567 City Aukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0223000060 Address: 116 ANDOVER PK E TUKW Project Name: FEDEX OFFICE ELECTRICAL PERMIT Permit Number: EL13-0567 Issue Date: 07/29/2013 Permit Expires On: 01/25/2014 Owner: Name: PIETROMONACO/PB L L C Address: 7900 SE 28TH ST STE #310 , MERCER ISLAND WA 98040 Contact Person: Name: MARY RYAN Address: PO BOX 3749 , MISSION VIEJO CA, 92690 Contractor: Name: AIM ELECTRIC LLC Address: 10002 AURORA AV N , SEATTLE WA 98133 Contractor License No: AIMELEL918RG Phone: 949-582-3735 Phone: 206 909-4907 Expiration Date: 12/07/2013 DESCRIPTION OF WORK: TENANT IMPROVEMENT REMODEL OF EXISTING SPACE INCLUDING DOORS, PARTITIONS, CEILING, ETC. MEP WORK Value of Electrical: NRES: $45,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: Date: $1,083.13 2008 7-)ci- 13 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting oft =• construction or t -,•�� 1`� Signature: Print Name: ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating rformance •j work. I am authorized to sign and obtain this electrical permit. k, 44e c Date: 7/79/ 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL13-0567 Printed: 07-29-2013 • • PERMIT CONDITIONS Permit No. EL13-0567 **ELECTRICAL** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL13-0567 Printed: 07-29-2013 VVA'--u.A1l, CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 ' ?—I kJ. Electrical Permit No. 1L.\ Os() 7 Project No. Date Application Accepted: Date Application Expires:0-N1 \ -13 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: / / (Q ,4Nrr4 t) Vf - �•et k F'4S-Suite Number: Tenant Name: fib [) C. 4 PROPERTY OWNER Name—Th E. 4Aa)0 Vet &9 .- V6,.. Address:4/4.46---t 4.A ir. YD s,/...4 , City:s f,9/6, State:W�_ Zip: 9/j CONTACT PERSON — person receiving all project communication Company Name: T 5 J Name: / ,/'h eie .t ,. f —A, 4 f s Address: 80 3�.�/ ,d . Ci : . State: Zip ass/dam �•� e.t— g�4 g...4" Phon 4 %'S 5-- 9q-7 / � � ,� Email: �4'4,t ya t .e y/ftegiot e r(P - 4A New Tenant: F19or: Yes El ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: T 5 J Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: f Valuation of Project (contractor's bid price): $ / O VA) Scope of Work (please provide detailed information): 0/40— V34.4-4-447' V & . Will service be altered? ❑ Yes ErNo Adding more than 50 amps? erYes ❑ No Type of Use: Type of work: 0 New 0 Addition 0 Service Change Remodel Ei7Tenant Improvement 0 Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms-Applications On Line\2011 Appltcations\Electrical Permit Application Revised 8-9-11 dues Revised. August 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings , $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service tinge $54.60 (up to 5 circuits) ❑ Circuits added/altered without rvice change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 O Manufactured/mobile home servi $84.00 (excluding garage or out (ding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: Date: Day Telephone: City H:\ApplicattonsWortms-Applications On Line\201 I Applicattons\Electncal Permit Application Revised 8-9-1 1 docs Revised August 2011 bh State Zip Page 2 of 2 Parcel No.: Address: Suite No: Applicant: 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov 0223000060 116 ANDOVER PK E TUKW FEDEX OFFICE RECEIPT Permit Number: Status: Applied Date: Issue Date: EL13-0567 ISSUED 06/11/2013 07/29/2013 Receipt No.: R13-02498 Initials: User ID: TLS 1670 Payment Amount: Payment Date: Balance: $63.00 08/29/2013 07:52 AM $0.00 Payee: AIM ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 025010 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 Total: $63.00 63.00 rinn• Rcnoin4_!1R Printarl• 11R-9Q_9fl11 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0223000060 Address: 116 ANDOVER PK E TUKW Suite No: Applicant: FEDEX OFFICE RECEIPT Permit Number: EL13-0567 Status: APPROVED Applied Date: 06/11/2013 Issue Date: Receipt No.: R13-02225 Initials: WER User ID: 1655 Payment Amount: $866.50 Payment Date: 07/26/2013 01:07 PM Balance: $0.00 Payee: LAKEVIEW CONSTRUCTION INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 306800 866.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 866.50 Total: $866.50 rine Paraint-na Printed: 07-26-2013 City of Tukwila , 2 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0223000060 Address: 116 ANDOVER PK E TUKW Suite No: Applicant: FEDEX OFFICE RECEIPT Permit Number: EL13-0567 Status: PENDING Applied Date: 06/11/2013 Issue Date: Receipt No.: R13-01857 Payment Amount: $216.63 Initials: WER User ID: 1655 Payment Date: 06/11/2013 01:51 PM Balance: $866.50 Payee: MULVANNY G2 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 087445 216.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 216.63 Total: $216.63 PrintaA• (1R-11-2013 INSPECTION RECORD Retain a copy with permit 6/15 - 0 ql INSPECTION NO. PERMIT NO. -CITY OFTUKWILA BUILDING DIVISION 6300 South.center Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 431-2451 Project: L Type of Inspection: 2.rov Address: MO APE Date Called: Special Instructions: Date Wanted: q ?,3 _p•ml Requester: Phone No: igApproved per applicable codes. COMMENTS: ElCorrections required prior to approval. 0, Inspector: Date: 07/2413 r3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION- RECORD Retain a copy with permit 6,130)191 PERMIT NO. CITY. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: 4100 Foo4ritt Address: _ ii(0 A4146 - 'f1 Date Called: CD J® �u5 (JJ1—Ostsi� (vJ i� Special Instructions: Date Wanted: qfy n Requester:. vet Std t 0 ck4v r r — 8J0k eJatikotlir eitAkc IA d4 15AJicrot&5 (Ai Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: — 644 ?go-tecri, > ZFAutap rak tAttlek Foo4ritt --:5t a 1 5 3 ij c Ci P5 To 4Q•tt9 - / }� ' t o 1. k o f c- -K J t R 5 4. xiefi CD J® �u5 (JJ1—Ostsi� (vJ i� - � C``,� ., b rSC. AJ6C.( tAJ Th JkJir NIAd1 t (941-€ kS P sc &&) P6J ! tAkCalt 1T kr.11 Sri • Me Wetskti um+ie 7765 K(40184?-, Rpf ,A. 7 vet Std t 0 ck4v r r — 8J0k eJatikotlir eitAkc IA d4 15AJicrot&5 (Ai Date: `i t? /#3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 4,./_05-47 Retain a copy with permit Cm J INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIYVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Cr.' CP e ' Type of Inspection: 7063 Address.l ( W / Date Called: Special Instructions: Date Wanted: �Q 7,r� C3 J tJ p.m. Requester: Phone No: DApproved per applicable codes. 1J Corrections required prior to approval. COMMENTS: &-Koori JA -t,9 Inspector: Date: 600/0 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION'RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tZ (206) 431-3670 3-oSG% Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: 7001 700 Address: i le . � Date Called: Special Instructions: ' - • Date Wanted: 8 Z.f .m. Requester: Phone No: y0Approved per applicable codes.Corrections required prior to approval. per applicable codes. COMMENTS: 1)-K. — Si.46 CPAJLI$ AnID 70°3 D.K. I IA)3 cgr Inspector: 46\ n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 0-324 (n INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F...; (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: vv�00 Address: t %A -Pe Date Called: Special Instructions: - Date Wanted: '4r...on m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ?fr eJK Etekci4 Inspector: 664,16k REINSPECTIONFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 07 3 t ? •PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0567 DATE: 08-13-13 PROJECT NAME: FEDEX OFFICE SITE ADDRESS: 116 ANDOVER PK E Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS. aif2ng Division Public Works n Fire Prevention Planning Division Structural ❑ Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08-15-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined Incomplete: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-12-13 Approved Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 %MIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0567 PROJECT NAME: FEDEX OFFICE SITE ADDRESS: 116 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # DATE: 06-11-13 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: ;tliding Dlv�� s o Public Works ❑ Fire Prevention Structural Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-13-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 174 Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 07-11-13 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 PROJECT NAME: � c -e 1 F C . i C� SITE ADDRESS: ' (, } 'PIL PERMIT NO: L L( ' ©S IQ % ORIGINAL ISSUE DATE: ( 3 REVISION LOG REVISION DATE RECEIVED STAFF NO. INIT ALS Summary of Revision: �irevs 1.sR � aes ivy S�� -evs -cm,- iA o : yvveAn4 Sa`Y r Trek, t: \ec �coNAloaktig.,e Received by: ,lC-U Qi) 0 h VVS ISSUED DATE STAFF INITIALS REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: August 12, 2013 l3-0%� Plan Check/Permit Number: -1D13 °6-(Btlitdt i O Response to Incomplete Letter # ❑ Response to Correction Letter # • Revision # 1 after Permit is Issued ® Revision requested by a City Building Inspector or Plans Examiner Project Name: Fed Ex Office - 116 Andover Park E Project Address: Contact Person: 116 Andover Park East, Seattle WA 98188 Mary Ryan Summary of Revision: Revised MEP Systems o avoid impeding upon the property In Phone Number: (949) 582-3735 r con . • . . roo -op • 1••- - - Minor base plan changes. - Electrical changes include the revised power for HVAC equipment - Added notes about hanging lights from aircraft cable RECEIVE CITY OF TUKWILA - electrical changes in sales area around new columns. AUG 1 3 2013 PERMIT CENTER Sheet Number(s):-7/4"‹,191717074444, Itft '`0, 0,1`+'0,1 �, E-1.0, E-2.0, 3-3.0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on \applications\forms-applications online \revision submittal Created: 8-13-2004 Revised: 1-2009 Contractors or Tradespeople POI- Friendly Page • Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company AIM ELECTRIC LLC 2069094907 10002 Aurora Ave N Seattle WA 98133 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602971337 Active AIMELEL918RG Electrical Contractor 12/7/2009 12/7/2013 General Unused Electrical Administrator INFORMATION License MITALCT258M9 Name MITALAS, CONSTANTINOS T Status Active Business Owner Information Name Role Effective Date Expiration Date MITALAS, ANDREAS Agent 12/07/2009 MITALAS, ANDREAS C Partner/Member 12/07/2009 MITALAS, IRENE Partner/Member 12/07/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC 514722 12/01/2009 Until Cancelled $4,000.00 12/07/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/29/2013 UGHTNG CODED NOTES 1. PROVIDE WALL MOUNTED, DUAL RELAY, MOTION OCCUPANCY SENSOR LIGHTING CONTROL MADE BY 'WATT STOPPER', MODEL #PW -200. RELAYS SHALL BE SET TO "MANUAL ON" AND "AUTO OFF". 2. PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN CONCEALED LOCATION AND MAKE ALL FINAL CONNECTIONS FOR 120 VOLT SIGN FURNISHED BY TENANT. COORDINATE EXACT LOCATIONS WITH TENANTS CONSTRUCTION MANAGER. WIRE THROUGH PHOTOCELL MOUNT PHOTOCELL ON ROOF ABOVE ENTRANCE. 3. CONNECT TO SWITCH 4. CONNECT TO SWITCH 5. CONNECT TO SWITCH 6. CONNECT TO SWITCH 7. CONNECT TO SWITCH 8. CONNECT TO SWITCH "a" & "b". "c" & "d". "e" & "f". "9" & "h". & "J . "k" & "1". 9. CONNECT TO SWITCH "m" & "n". 10. EXTERIOR EGRESS LIGHTING IS PROVIDED AND POWERED BY LANDLORD UNDER A SEPARATE CONTRACT. • 11. LIGHT FIXTURES LABELED "EM" CONTAIN 90 MINUTE BATTERY BACK-UP FOR EMERGENCY EGRESS ILLUMINATION. 12. MASTER SWITCHBANK LOCATION. 13. PROVIDE NEW TIMECLOCK 'TC' AND NEW LIGHTING CONTACTORS 'LC1' & 'LC2'. REFER TO LIGHTING CONTACTOR SCHEDULES ON THIS SHEET AND SPECIFICATIONS ON THIS SHEET FOR ADDITIONAL INFORMATION. TIMECLOCK SHALL BE DIGITAL, 365 -DAY SKIPPER TYPE WITH HOLIDAY PROGRAMMING AND WITH EXTERNAL OVERRIDE CAPABILITIES (TORK, PARAGON, OR ACCEPTED EQUIVALENT). COORDINATE ON/OFF SCHEDULING WITH FEDEX OFFICE PROJECT MANAGER. 14. PROVIDE 2 -HOUR OVERRIDE TIME SWITCH EQUAL TO INTERMATIC FF SERIES. OVERRIDE SWITCH SHALL SERVE AS THE EXTERNAL OVERRIDE SIGNAL TO TIMECLOCK 'TCI' POLE #1. PROVIDE PRINTED LABEL AT SWITCH LOCATION TO 5 READ "OVERRIDE SWITCH". REFER TO LIGHTING CONTACTOR SCHEDULES, LIGHTING CONTROL DETAIL, AND SWITCH BANK DETAIL 1 ON THIS SHEET FOR ADDITIONAL INFORMATION. 15. LL LI T Fl -ES IN S RA H LL BE H NGF FROM AIRCRAFT CABLE. E.C. SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO INSTALL ALL UGHT FIXTURES AT SAME HEIGHT AS DIFFUSERS. ALL LIGHTING AND DIFFUSERS SHALL BE MOUNTED AS HIGH AS 0 SI LE UGHTNG GENERAL NOTES A. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL LIGHTING BRANCH CIRCUITS SHALL BE PROVIDED WITH (2)#12 AND (1)#12 GND IN 3/4" CONDUIT FOR EACH 20 AMP CIRCUIT. B. EMERGENCY AND EXIT FIXTURES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. C. EMERGENCY FIXTURES, EMERGENCY BATTERY BALLASTS SHALL BE PROVIDED WITH AN UNSWITCHED "HOT" TO PROVIDE CONTINUOUS POWER TO BALLAST EVEN WHEN FIXTURE IS SWITCHED OFF. D. ALL NIGHT LIGHTS (SHOWN WITH "NL" DESIGNATION) SHALL BE WIRED AHEAD OF SWITCHING. FELD VERFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 2 HOUR OVERRIDE - TIMER SWITCH TO CONTROL TIMECLOCK POLE #1 - LC1 PANEL A -0 c)-0 0 O -0 O- O a O -HF ® DETAL NOTES 1. REFER TO CONTACTOR SCHEDULE LC1 ON THIS SHEET FOR CIRCUITS TO BE CONNECTED TO CONTACTOR. 2. REFER TO TIMECLOCK SCHEDULE ON THIS SHEET FOR CIRCUITS TO BE CONNECTED TO TIMECLOCK. SWITCHES "a - n" /0 11 �-C GENERAL LIGHTING )LIGHTING CONTROL SCHEMATIC SCALE: NONE kk STOREFRONT 1-11 RECEPTS LIGHTING CONTROL DESIGN INTENT EVENT: NORMAL BUSINESS HOURS (HOURS TO BE DETERMINED BY FXO PROJECT MANAGER) - LIGHT SWITCHES AT THE LIGHTING SWITCH BANK SHALL CONTROL THE LIGHT FIXTURES. EVENT: CONCLUSION OF BUSINESS DAY (TIME TO BE DETERMINED BY FXO PROJECT MANAGER) - TIMECLOCK SHALL SWEEP "OFF" ALL LIGHTS EVENT: AFTER BUSINESS HOURS - LIGHT FIXTURES SHALL REMAIN "OFF". - IF AFTER HOURS CONTROL OF THE LIGHT FIXTURES IS DESIRED, THE OVERRIDE SWITCH SHALL SERVE AS AN OVERRIDE SIGNAL TO THE TIMECLOCK AND THE LIGHT SWITCHES SHALL BE CAPABLE OF CONTROLLING THE LIGHT FIXTURES AGAIN (2 HOUR OVERRIDE MAX). 0 0 0 DAYLIGHT AREA DAYLIGHT AREA (STOREFRONT) (STOREFRONT) .a 0 ENTRY & SELF-SERVICE LIGHTING 'c' 0 ENTRY & SELF-SERVICE LIGHTING 'd' 0 0 0 0 RETAIL LIGHTING 'e' 0 RETAIL LIGHTING 'f' PACK AND SHIP & PRODUCTION LIGHTING .9. 0 PACK AND SHIP & PRODUCTION LIGHTING 'h' 0 0 PRODUCTION & SIGN & GRAPHICS LIGHTING .i. 0 0 0 O O O 0 PRODUCTION & SIGN & GRAPHICS LIGHTING 0 COMPUTER SERVICES LIGHTING 'k' 0 COMPUTER SERVICES LIGHTING 0 0 GI 0 0 BREAK AND HANDLING LIGHTING m 0 BREAK AND HANDLING LIGHTING .. n 0 0 0 LIGHTING G OVERRIDE (AFTER HOURS) NOTE: SWITCHES SHALL BE LABELED AS SHOWN ABOVE SALES LIGHTING SWITCH BANK SCALE: NONE LIGHTOLIER - ULTRA MAX BALLAST & ULTRA LAMPS - DUAL VOLTAGE QTY (EA) TYPE MFG CATALOG # DESCRIPTION GE LAMP PART NUMBER LAMP DESCRIPTION LAMP QTY PER FIXTURE AREA IN BRANCH 72 A10 LIGHTOLIER CFS2GPF332UNVGI 2'x4' Recessed 3 -Lamp DIRECT/INDIRECT PERFORATED GE ULTRAMAX BALLAST (PROVIDE FIXTURE WITH 2 BALLASTS) GEF28T8SP41UMX (00257) T8 Ultra Watt -Miser 3 Express/Computer Services/Production / Offices 15 A20 LIGHTOLIER CFS2GPF332UNVG1-0X5 2x4 Recessed 3 -Lamp DIRECT/INDIRECT PERFORATED GE ULTAMAX BALLAST WITH EMERGENCY BALLAST 1100 - 1400 LUMENS (PROVIDE FIXTURE WITH 2 BALLASTS) GEF28T8SP41UMX (00257) T8 Ultra Watt -Miser 3 Express/Computer Services/Production / Offices/Breakroom 2 A5 LIGHTOLIER SLB2SFSVA332120GI-CUL 2'x4' Surface Fluorescent 3 -Lamp w/Prismatic Lens (PROVIDE FIXTURE WITH 2 BALLASTS) F32T8XLSP411SWMECO (GE #48532) T8 Ultra Wall Miser 3 Restrooms/Breakroom/Handling Area, as required 4 X1 DUAL -LITE LXURWE Universal Exit Sign, Red Letters, White Housing t?:A.. - As required / e ELECTRICAL LIGHTING PLAN SCALE: 1/4' 2009 Seattle EnergyCodecompliance Formtor Nonresidential and Multifamily Residential Interior Lighting Summary -2009 Seattle Energy Code Compliance Forms for Nonresldentlafand Multifamily Residential LTG -INT Revised. December201 Q Project Info Project'Address*aux omF1ce _ sOEBILs',, WA Pate 5/9/2013 Sib AHAaaER-walk Erin For'Building Department Use SEATFLE', E1: 98188 ApplicantNarhev Erin ssnleEENts Applicant Address: . 1534 ALEXANDRIA PIKE,- €a - mwcmS, RSr-41875 Applicant Phone: 959-442-8058 Project Description 0 New Building • Addition I % Alteration D Pla ns Included. requirements. Refer to SEC Section 1513 for controls and commissioning ClJlll�l�]311Ce 0 Prescriptive • Lighting PowerAllowance Ci Systems Analysis - (See{lua6frcationcl cdtitst,(l):lhdicatePrescriptive&LPAspacesclearlyon.plans.) Alteration E5CCeS-19TIS- (check, appropriate box -sec. 11323) Q No changes are being made to the lighting and the space use has not changed ■ .Lessthan V00-54)) 2ffs.athe, fixtures or of the lampsplus ballasts alone -are -altered, added, or replaced ((new)), installed wattage pot_increased, '& the space use has not changed: Maximum Allowed, Lighting Wattage (Interior) Location (floor-plariiroorn#) OccupariCiDeaciiptian Allowed Wats DOI'N2 ,F ,carobs nmtenor Area 'inft' AllowedxArea sales/Pxodnvkion- Retail 1;.33 6070 8081 Eekmaiiat;,,g- Ale & A2O -; 2' ' ;4! -Floucesoents. .,, 10 -.-90 100, Office -Areas- 118. 2, X,4' Flo escents ,6 -90 540 ' From Table 15-111(oyer):= documentall exceptions-onfbrm LTG=LPA Propose t -Lighting' Wattage (Interior) Total Alio Location .(floof Oiehlroorn #)' Fixture'Descri.ptioh. Numbefof: . Fixtures yyatts/ Fixture Watts 'Peoposed $aies' 11tH -"(-]128 - 5,! -it,: t'loaxescents- 69: '90 6210 Eekmaiiat;,,g- Ale & A2O -; 2' ' ;4! -Floucesoents. .,, 10 -.-90 100, Office -Areas- 118. 2, X,4' Flo escents ,6 -90 540 /al Aoom, ASO 2' 5 4i R1oseescants, 2: 90 180 Restxoorns 55 ',2'`X4' `F,lorneescenta 2 '90 180 Yes 15133 Daylight zone control Schedule with type andfeatufes, indicate !martens. E2.0 M.A. - daylight zones Indicate primary -zone and secondary zone -separately t?:A.. - parking garage Incficatedaylight zonein-parkinggarage - Ik.A. TotatProposed'YUattsplay, npt.exceed Total Allowed:Ulfettsfor Interio, Total Proposed Watts 8010 Notes. 1; For roposedFixture Descr tion indicate fixture' e, larnp'type e" T8 , nornber of lamps intheafixture, and ballast e if'Included: 'For p . p typ { g . %tYp { ) track li hti list' the lengthdf the, track' in feet in i''dditio to the fixture lamp, and allast inf rmation g n$ { ) a h p, b o 2.. For proposed WattsiFixture,, use manufacturer's listed maximum:,Input wattage of. the (not simply`the lamp wattage)' and other criteria as_ specified In'Section 1530. For line voltage track'lighting ,list' the greater of actual lurnlnaire.,wattage',or length of track multiplied by 50; Or the Wattage of current limiting,' devices_ or of the, transformer: For low voltage track,lighting listthe'transformer rated -wattage. &LListall'fiktures: For exempt light ng,- note.section and:exception number, and leave. Welts/Fixture blank: ParkingGara 'e Lighting --.Maximum. Allowed Wattage Location Occupancy Description AllowedWattstfl2 Gross Area (ft') -Watts Allowed Far king Garager L g eposed Wattage ightln F Location Fixture. Description -# of Fixtures Watts/Fixture Watts Proposed rate 5/9/2013 The fdlaafng information -1s necessary to check apermit 2009 Seattle Energy -Code, application fcr compliance with the fighting, nwtor,, and.transfo - mer requirements unlhe Applicability- (yes. no, n.a.) Code Section Component Information Require( Location on Plans Building Dept. Notes - LIGHTING GONTROLS.(Section 1513) A-7 P&S/PRODUCTION LIGHTING Yns 1513.1 The 2009'SEC Section 1510 specifies that-parking,garage lighting cannot betradect.With other interior Total Proposed Watts Schedule with -type, indicate locations. orwith.extenor fighting, 2009 Seattle Energy Cade .Compliance' Form for NonresidentialandMultifamily Residential Lighting, Motor, and Transformer 2009 Seattle Energy Code Compliance Forms fat Nonresidential Permit Plans Checklist and Multifamiy. Residential -LTG-CHK Revised December 2010 Project Address 'FEDEX OFFICE -- TUKWILA, DA rate 5/9/2013 The fdlaafng information -1s necessary to check apermit 2009 Seattle Energy -Code, application fcr compliance with the fighting, nwtor,, and.transfo - mer requirements unlhe Applicability- (yes. no, n.a.) Code Section Component Information Require( Location on Plans Building Dept. Notes - LIGHTING GONTROLS.(Section 1513) A-7 P&S/PRODUCTION LIGHTING Yns 1513.1 Local control/access- Schedule with -type, indicate locations. E2..0 COMPUTER SERVICES LIGHTING ares 1513.2 Area control's Maxirnurn limit per sr✓itch. E?'. 0 - SPACE Yes 15133 Daylight zone control Schedule with type andfeatufes, indicate !martens. E2.0 M.A. - daylight zones Indicate primary -zone and secondary zone -separately t?:A.. - parking garage Incficatedaylight zonein-parkinggarage - Ik.A. vertical:glazing Indicate vertical glazing on plans - - - - II :A. overhead' glazing indicate overhead glazing ,on plans tit . 1513.4 Display/exhib/special Indicate- separate controls (r:,2.. 1513:5 Exterior shut-off Schedule with type -and features, ind'icatelocation (a) -timer w/iackup Indicate location N,A. (b) ptiotoce0_ indicate locations_ Yea -1513:6 Inter: autoshut Mf lrtddcate location - Yes 1513.6;1 (a) occup. sensors Schedule with typeand locations E? o Yes 1513.6.2. (b) auto. switches Schedulewith type and features (back-up, ovemde cap'abildy); ,Indicate. size of zone on plans 52..0. '5.A. 1513:7 Hotelmotelcontrols irii-t catelocationofmem' master control§ Yes 1513.8 Commissioning, Indicate requirements for 'Ighting controlscommissioning 52,'.0 EXIT SIGNS (Section 1514)' Yes I 1514 Max. watts. lnlioatewatlsfor each exit sign 152 0 LIGHTING POWER ALLOWANCE (Section 153041532) ty.-.A,, 1531 interior lighting Summery Form.., Completedandattaehed. Schedulewithfixture type a lamps, -ballasts, watts per fixture N.A. -1532, Exterior Lightingompleted Summary Form- and attached. Schedule with fixture types, l lamps, ballasts, Watts per fixture MOTORS (Section 1511) l I 1511. 'IEtecii ftECH-MOT or. Equipment Schedule with hp, rpm, efficiency" ra of Ciency TRANSFORMERS (Section 1540) - tlr.A; 1540. ,Transiorners !Indicate Size and:efficiency I I If "no" is circled for any question, provide explanation: TIMECLOCK SCHEDULE "TC" SPECIFICATIONS: 2 POLE, 20A RATING, 120V, 120V COIL CONTROL REMARKS: TIMECLOCK AUTO ON /AUTO OFF POLE CIRCUIT DESCRIPTION 1 A-21 LIGHTING CONTACTOR -'LC1' 2 A-23 LIGHTING CONTACTOR -'LC2' r LIGHTING CONTACTOR SCHEDULE "LC1" SPECIFICATIONS: 8 POLE, 20A RATING, 120V, 120V COIL CONTROL REMARKS: TIMECLOCK AUTO ON / AUTO OFF COORDINATE SCHEDULE WITH OWNER POLE CIRCUIT DESCRIPTION 1 A-1 DAYLIGHT AREA LIGHTING 2 A-3 ENTRY/SELF SERVICE LIGHTING 3 A-5 RETAIL AREA LIGHTING 4 A-7 P&S/PRODUCTION LIGHTING 5 A-9 PRODUCTION/S&G LIGHTING 6 A-11 COMPUTER SERVICES LIGHTING 7 A-13 BREAK AND HANDLING LIGHTING 8 -- -- SPACE lig/. +/i, "Z./ A' ' . di- nor' LIGHTING CONTACTOR SCHEDULE "LC2" SPECIFICATIONS: 4 POLE, 20A RATING, 120V, 120V COIL CONTROL REMARKS: TIMECLOCK AUTO ON / AUTO OFF COORDINATE SCHEDULE WITH OWNER POLE CIRCUIT DESCRIPTION 1 A-25 STOREFRONT RECEPTACLES 2 A-27 STOREFRONT RECEPTACLES 3 -- -- SPACE 4 ---- SPACE-_...,ir">ln1Cn C(' KCVICYYw.� `.'• • COMPLIANC NECTH NFPA70 AUG 21 2013 City ot Tulorilla BUILDING DIVISION_. (A-19,21,23) X1 A10 BREAK HANDLING PACK & SHIP 124 RETAIL 125 A10 A10 A10 A10 A10 Al 0 A10 Al 0 (A-7) (A-1 A10 A10 Al 0 Al 0 A10 A10 A20 EM ENHANCED PACK & SHIP 126 LIGHT FIXTURE MOUNTIVG FITS LIGHT FIXTURES ON THE SALES FLOOR SHALL BE MOUNTED AT THE SAME HEIGHT AS THE DIFFUSERS (MOUNTED AS HIGH AS POSSIBLE). LIGHT FIXTURES IN THE OFFICE AREA SHALL BE LAY -IN STYLE. COORDINATE THE EXACT HEIGHT OF LIGHT FIXTURES AND DIFFUSERS WITH THE ARCHITECTURAL DRAWINGS AND G.C. ON SITE. A10 / CASH COUNTDOWN DM OFF A20 A10 / A10 A20 Al 0 Al 0 A20 Al 0 Al 0 Al 0 Al 0 EM EM/NL EM ENTRY (X l 111 A10 / A10 / A10 Al 0 Al 0 Al 0 Al 0 Al 0 Al 0 A20 / 11 Al 0 EM/NL SIGNS & GRAPHICS 113 0 A20 A10 A10 A20 Al 0 Al 0 Al 0 Al 0 A10 Al 0 EM 41 EM EM a SELF-SERVICE AREA A-11) 112 A10 A10 Al 0 A10 A10 A10 Al 0 A10 COMPUTER SERVICES Al 0 A20 11 127 A10 / A10 A20 \LY A10 MENS RESTROOM 114 EM/NL EM ADJACENT LEASE SPACE NOOTPARRTOFFWORRK//////////// REVISION.NO.:L �L.13� 65(01 RECEIVED CITY OF TUKWILA AUG 1 3 2013 PERMIT CENTER ARCHITECT 18200 VON KARMAN AVE I SUITE 910 IRVINE, CA 192612 t 949.705.0700 I f 949.705.0701 MulvannyG2.com I EXPIRES 0 2 L HL H KOHRS LO*EMANN NIEL ENGINEERS, PSC MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE. SUITE 11 FT. THOMAS. KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX ARCHITECTURAL PROJECT NO.: MEP PROJECT NO.: STRUCTURAL PROJECT NO.: CIVIL PROJECT NO.: 12-0253-01 A 12622.00 a3 U 0 116 ANDOVER PARK EAST SEATTLE, WA 98188 CENTER NO.: SITE ID NO: 5173 989630 PROGRAM: RELO STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SEATTLE, WA 98188 CONTEMPORANEOUSLY WITH ITS ISSUE DATE 04.26.2013 AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS and ENGINERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND IS CONTRARY TO THE LAW. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF KINKO'S INC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH FEDEX KINKO'S. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. FEDEX KINKO'S IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: /4\ \ CN 1- BLDG COMMENTS CN 2- FXO COMMENTS CN 3- FXO COMMENTS CN 4- FXO COMMENTS 07/11/13 07/11/13 07/28/13 08/01/13 CN 5- BLDG & MECH COMMENTS 08/09/13 A PERMIT SET ISSUE DATE: BID SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: 04.26.13 05.31.13 DRAWING TITLE: ELECTRICAL LIGHTING PLAN DRAWING NUMBER: E-2.0 PANEL NAME A OLTAGE 208 PHASE 3 WIRE 4 LOCATION BREALSERVER.AREA SOURCE WIREWAY 12,5A NI_C33, SIGNACE 1.2 120 125 E EQUIPMENT RECEPTACLES 74.9 120 1.00 74.9 e•--..--..e--se-se-v--.."-- 'WATER HEATER 2.5 208 LRIvIHC R :HVAC EQUIPMENT R MIICmap 1: 11 DESCRIPTION BREAKER DE ' ' I ION KHA& DESCRIP1 iON BREAKER L RMHC HC FEEDER AMPERAGE AMPS Al POLE AMP POLE AH -,4 1 C 1 PCiLE 1 10 • 20 1 2OE I DAYLIGHT AREA ' TING 21 !OMNI! TDS450 20 1 74 .1.8 2 3 • 2 3 0.9 20 I P05- PACK AND S11P COUNTER 20 1 ENTRY/SELF SE '' E LP:I-JUNG MINIieill :HMI T S CONTROLLER 20 1 74 02 5 5 03 4 5 11 1POS- PACK AND aIIP COUNTER 1111111111111111111111111M 20 1 RETAIL AREA LI II II ]NG 11, i!!!iiii II, !;;' .::: 29 TDSSCAlsTh,TER 20 1 6 1_8 TELEPHONE CABLING 05 10 7 0_9 POS - FRONT COUNTER 1.9 111111111111.1111Piiiiiiiliiiiiiii DPWP, DEWS 201 1 P&SiPRODU 1- 10 IGH TING 1411511 ..r 111111111111111L : 7020 20 1 S 03 1 0.5 9 9 11 POS- FRONT COUNTER OMR 2.3 nall IRC5051F 20 1 PRODU ir ' ' :[[ I IGHTING MIN:1MM -1 (2) SONY PICTURE STATIONS 20 1 10 / _0 23 0.7 10 10 11 13 COKE COOLER - FRONT COUNTER !'''''''"": I:j ...' :, 19 COMB TREADER, MAGNA PUNCH 20 1 COMPUTER RVI1 SLIGHTING 111111111 .;;;.4';;,.. 18 SONY PICTURE STATION 20 1 12 0_5 MG 0.5 MFR 12 13 09 P05- FRONT COUNTER 1.7 . .. . _ MAGQ4, PUNCH, COIL DiMTER 20 1 BREAK A HA P , ,INGLI�TTh1G , 27111111111MIN MINN JAC5045C, EPS-07 20 IL 14 11 0.5 0,5 4.6 14 15 0,9 POS- FRONT COUNTER .: 21 iiiiiiigilini LAM DIS. 80 20 1 OFFICE [ [LIGHTING 21 BROTERMFC722O, EPS -06 20 1 16 1.2 1 0.5 16 17 11 17 , . ,E, !::.i15141$11 2.1 - -- 20 1 STOREFRONT URCIETiiigqiiiliiiiiiii iiiiiiiiiliiiiiiiii iiiiiiiiimil i!iiiEmii! 2 4 BROM 220 EPS -06 - - ,, 20 1 18 12 HC 0_5 1 18 19 WORK STATION - S&G 02 tim,!!, .! IRK 05F L 20 1 TIMELOCK 410 01'il IP' iii E •::. EPREG EP 3 It • T 20 [ 20 [0.5 20 06 0_1 20 21 1 GERBER. EDGE 02 21 T 20 -- LIGHTING 11A ORI'LC1' i: ii: . Ii .ir: [EPREG, EPS -03, .3, RT 20 1 22 0_5 '' 1" COY/. RECEPTS 11 10_7 22 23 1 15" & 30 NINYL CUTTER 02 22 20" IL CUTTER. T 20 1 UGHTINGCONTACTO1ULC2F 1111111111111111111Min 101 DESIGN. CENTER. EP I 20 1 24 OA " iiE PHNOM 0.4 20 24 25 I OA 20! - , giiiiiiiii!.., , , , , 16 I STOREFRONT RECPTACLES 1 COMPUTER WORXSFATIONS 20 1 26 03 CAI COUNTDOWN [OFFICE 0A iiiiiiiiiiiiiii Ei SPARE „.....:„. 26 27 2 0,4 ::: .: 2-0 1111:1111111111111:1 JOG�R, PADDER 20 1 STOREFRONT PTACLES••.---,:••• .•• ••• ••• ••• ••• .. ••• ••• ••• ••••.••• .: ••• -. NiMliMiEiii COMPUTER WORKSTATIONS •:!:!:E1 28 03 1 04 IPIIMP03MINK 28 29 ----- .:.:.:.,•„:„..• :.: 2_6 CHALLENGE DRILL 20 1 SPARE :!0::.:: DNEDIEliiiiiiii 03 COMPUTER WORKSTATIONS 20 1 30 0_7 20 1.6 OFFICE 30 31 1 BOOKLET MAKER, FOLDER 0.5 (3)#1 , 10 1 'aND LN 3/4" ,COND _ 20 1 MOTORIZED DOOR 1211111111111111 COMMUTER. WORKSTATIONS 20 1 32 01 0.8 1 32 33 1 I,11 1:1111111111011111 - illai ............ 20 1 IRC5045F, EPS -07 IIIIIiIIIIIIIIIIIII 5 jAqm - iiiiiiiiiiiiiiiiiii COMPUTER WORKSTATIONS liFE;iiiiiEiEiEEEk 20 IL 35 03 2 .5 20 I 34 35 TITAN 1264WF 11 25 SPARE 20 20 1IP45045C, EP :2 ,,','. ,:, 1., ;; 1.0 XEROX N5500 20 1 1236 20 -- -- 37 2.5 11111:11illif ENE TARE 20 1 20 1. A3ARE, 36 pHAffi R, 7760 20 1 IA 20 1 38 39 . :•:. ... • ::::[.. . [ .. 2:: . ::: SPARE •••-•••• 20 1 20 1 SPARE iiiIiiiliiiniii0.0MN . ISPARE 20 1 20 1 SPARE 40 41 20 I. I 20 1 SPARE 42 , ;ii ," ..:::: 0_0 SPARE 20 1 134 II = PROVIDE HID RATED BREAKER_ S=---- PROVIDE SWITCHLNGDUTY RATED BREAKER-. T = INDICATE S TIME CLOCK CONTROLLED CIRCUIT G= PROVIDE A -CEI BREAK.ER. L = PROVIDE LOCK OFF HANDLE BREAKER 20 1 42 TOTAL CTED LOADMII 113 9.6 11_3 li--- Immure RID RATED BREAKER_ L= LITE DEMAND 125% 0..0 41_0 0.0 0.0 0.0 I R = RCPT ISUBEED TCL FROM KVA. M =MISC 000 E SWITCFIINGDUTY RATED BREAKER KVA TOTAL C NNECTED LOAD 3241 T L imeATEs TIME CLOCK CONTROLLED CIRCUIT L=LrrE DE IA 12 %I .-- LS 221 IAKVA KVA KVA _ G= !PROVIDE A GFI BREAICER. j L= !PROVIDE LOCK OFF HANDLE BREAKER R= T D % 411) NOTES M =MI SC DEMAND 125% H =11VAC DEMAND100%TFIbC, -‘1F11-<C R= RCPT 0_0 KVA 1..:PROVIDE (2)414(1)#1=s1Di.314"C FOR ALL BRANCH CXTS UNLESS C = COOL DEMAND 100%1FC/I, IF Ce.H PROVIDE LOCK OFF HANDLE BREAKER, 00 KVA srATED OTHERWISE, TOTAL PANEL DE1AND= 350. E..yA :z. -'-' 3. , PROVIDE HACR RATED BREAKERSON ALI; M. QTQR- LOADS - P ,' I E LOCKING TYPE BREAKERFOR ALL LI:Wt.:SAFETY AINTI) - INIGUT LICHTINGARANCI-1 CIRELTIT S. 1.00 KVA 350 'Mk I PROVIDE (2)12(1)#12014D,314" C FOR ALL RANCH CCTSUNLESS STATED OTHERWISE. C =CL DEN1A103 100% IF C>H, 0% IF C<F1 r r 1 I i KVA ,4 'g7.2 AMP 516 __ 2. ; _L, _ 1 i - ,L r ___ . [,-- ,, 1.00 '3_ _ * rT PHA ES SHALL --I BE BALANCED TO WITHIN 107 _......i____/ , . BE r I I 1 -Lt BALANCED PA NAME .13 VOLTA 20:8 PHA 3 WIRE 4 LOCATION BREA1C/RVER AREA SDURCE W1REWAY 1AMCW SIGNACE 1.2 120 125 E EQUIPMENT RECEPTACLES 74.9 120 1.00 74.9 e•--..--..e--se-se-v--.."-- 'WATER HEATER 2.5 208 LRIvIHC R :HVAC EQUIPMENT HC BREAKER 1: 11 DESCRIPTION ICV.A.THA SE DEWRIPTION BREAKER, LR L R HC HC FEEDER AMPERAGE AMPS Al POLE , A 1 B C AMP POLE 1 02 0.5 BHP • 20 1 POS- PAM AND SUP COUNTER 1.9 11111111111N :::111i0 DPWP DPWS, BROTHER 5370 DW .,..--, 20 1 DC WIRE 14 • 74 ........".-.."....."...."...."....w.-.....-"-..".....".....A.-."....."..-".-."-1 2 3 • 03 1 OUTLETS AND SWITCHES 20 I P05- PACK AND S11P COUNTER 11111111111111111i1 23 0111111iiiigIRCSOSIF 20 1 • 1.8 62 GENERAL CONDUIT & WIRING 74 4 5 5 03 02 MFR 20 1POS- PACK AND aIIP COUNTER 1111111111111111111111111M 1.5 BROTHER MFC7220 20 1 -- 1.0 • 6 7 TELEPHONE CABLING 05 10 20 1 POS - FRONT COUNTER 1.9 111111111111.1111Piiiiiiiliiiiiiii DPWP, DEWS 20 1 INIMMI:l. CU -1 (ON PLAT ,SERVER 14 2 0 CU -1 S 9 1 0.5 9 20 POS- FRONT COUNTER OMR 2.3 nall IRC5051F 20 1 33 1.8 ..„... _ P.O.S. DATA CABLING 10 11 23 0.7 10 11 20 1 COKE COOLER - FRONT COUNTER !'''''''"": I:j ...' :, 19 COMB TREADER, MAGNA PUNCH 20 1 SERVER [CABINET 11 5:41. FC -1 (AB)VE CEILING) 45 2 12 13 MG 0.5 MFR 12 20 1 P05- FRONT COUNTER 1.7 . .. . _ MAGQ4, PUNCH, COIL DiMTER 20 1 1 12 - i!! ' ,. vii":4 ' (3)#6, (1)410 GND IN 1" CONDUIT - 14 15 0.5 0,5 4.6 MFR 10 1 POS- FRONT COUNTER .: 21 iiiiiiigilini LAM DIS. 80 15 2 20 1.6 REFRIGERATOR 07INIMOTORIZED DAMPER 16 17 1 0.5 20 IPOS-FRONTcOUNTER 17 , . ,E, !::.i15141$11 2.1 - -- 13 - EC 16 2 wATER HEATER (ABOVE CEILING) 111:111:11111:111i: $ ''' 18 19 HC 0_5 1 20 WORK STATION - S&G . tim,!!, .! IRK 05F 20 2 16 - [ 20 21 20 06 0_1 0.5 20 1 GERBER. EDGE 22 21 -- 04 11 20 1 22 23 '' 1" COY/. RECEPTS 11 10_7 20 1 15" & 30 NINYL CUTTER 11111111111M !Ilia 22 20" IL CUTTER. 15 2 04 16 20 24 25 " iiE PHNOM 0.4 20 1 20 I HP z6100 20! - , giiiiiiiii!.., , , , , 24 - 16 26 27 CAI COUNTDOWN [OFFICE 0A iiiiiiiiiiiiiii Ei SPARE „.....:„. 20 15 2 HPz6100 ::: .: 2-0 1111:1111111111111:1 JOG�R, PADDER 20 1 27 1.6 0.5 28 29 1 04 IPIIMP03MINK E SPARE, - ----- .:.:.:.,•„:„..• :.: 2_6 CHALLENGE DRILL 30 2 28 2.2 05 30 31 20 1.6 OFFICE 20 1 BOOKLET MAKER, FOLDER 3-g 111110111111111111111 (3)#1 , 10 1 'aND LN 3/4" ,COND _ -- 22 31 05 32 33 0.8 1 MANAGERSOttiCE 20 1 AIR FEED FOLDER 1:1111111111011111 - illai ............ 20 1 32 33 34 35 2 .5 20 I 30 2 TITAN 1264WF . 25 SPARE 20 1 34 35 36 37 2.5 20 -- -- (3)410, (1)#10 'GM. E',,T 3/4" COND. 2.5 11111:11illif ENE TARE 20 1 36 38 39 04 20 1 SPARE iiiiiiiiiiiiililig 0.0 --,---- . :•:. ... • ::::[.. . [ .. 2:: . ::: SPARE •••-•••• 20 1 40 41 20 1 SPARE , ... illiiililin MiliiitiMiliiii 01 SPARE 20 I. I 42 40 41 SUBFED TCL FROM TOTAL COI'sTNECTED LOAD 1/9 11.7 134 II = PROVIDE HID RATED BREAKER_ S=---- PROVIDE SWITCHLNGDUTY RATED BREAKER-. T = INDICATE S TIME CLOCK CONTROLLED CIRCUIT G= PROVIDE A -CEI BREAK.ER. L = PROVIDE LOCK OFF HANDLE BREAKER 20 1 ARE, 1111111111111111111 ..1 0.00 20 41.00 L= LITE DEMAND 125% 0..0 41_0 0.0 0.0 0.0 KVA R = RCPT DEMAND 100% KVA. M =MISC DEMAND 125% , KVA NOTES 1- PROVIDE (2)#12,(1)#12G,3i4"C FOR ALL BRANCH =SUNLESS STATED OTHERWISE - 2_ PROVIDE HACR RATED BREAKERSON ALL MOTOR LOADS. 3_ PROVIDE LOCKLNG TYPE BREAKER. FOR ALL Litt: SAFETY AND WET LIGHTLNGBRANCH CIRCUITS. , H =HVAC , DEMAND 100%1F H>C, 0% IF 1-1‹ KVA C =COOL DEMAND 100%1F C>I1,_ 0%IF C41 1 1 KVA TOTAL PANEL DEN i = X * PHASES SHALL BE BALANCED TO WITHIN 10% * 41.:0 KVA 1.00 L = LITE 411) KVA 113.9 AMP,_ 0= PANEL NAME C 'VOLTACE 20-8 PHASE 3 WIRE 4 LOCATION BREAKfSERVERAREA KIURC'E WIREWAY: 200A NLCB. SIGNACE 1.2 120 125 13 EQUIPMENT RECEPTACLES 74.9 120 1.00 74.9 e•--..--..e--se-se-v--.."-- 'WATER HEATER 2.5 208 1.25 R :HVAC EQUIPMENT HC 480 - BREAKER DESCRIPTIONA KVA/PHASE 1 1 B1., f C ..1.r 1.... 0 14, BREAK -ER L R TOTAL HC FEEDER AMPERAGE AMPS CP CORD AND PLUG CONNECTION Amp POLE 4,.. 1 4 1 , o 208x 133 ,THEREFORE. inE 400 AMP SERVICE 02 EMERG BHP • 20 WATTS WIFI RECEPT 761111111111111 PPM ACU -7I (ON CRAM) 80 3 DC WIRE MC TYPE • 74 ........".-.."....."...."...."....w.-.....-"-..".....".....A.-."....."..-".-."-1 i 3 • 02 1 OUTLETS AND SWITCHES AIR COND. UNIT 20 1 SECURITY RECEPT 1111111111111 ' ICHI 4,11111-11(3)#3„. (1)48 (DIN 1714" CONDUIT- • 62 GENERAL CONDUIT & WIRING 74 EC 4 5 MFR 02 MFR • H C 20 1 TELPFIONE BOARD .71 :•:.,•,..-..,„ •,... „... nelillin iliii Aiiii 7- 4- -- 1 • 745 TELEPHONE CABLING 7 10 EC • CS 20 1SERVER CABINET 33 101111111 INIMMI:l. CU -1 (ON PLAT ,SERVER 15 2 0 CU -1 • 23 1 2 9 1.20, 22.1 • EC CABLNET 33 IIIIIIiIIIIIII0 (3)#.8 0)410 GNDIN3i4i, CONDUIT iii!!!!!!,!. ..„... _ P.O.S. DATA CABLING LOW HC 23 HC 10 11 EXHAUST FAN 1_0 • TENANT'S 208 VOLT PANEL "A" 20 1 SERVER [CABINET :!!!g!!!iliiE i;:;;iiE!;;;; 5:41. FC -1 (AB)VE CEILING) 45 2 • MFR MG 4.6 MFR 12 13 • 12 EC 0 • 20 1 MICROWAVE - i!! ' ,. vii":4 ' (3)#6, (1)410 GND IN 1" CONDUIT - • 38 0.5 4.6 MFR 14 15 MG 01 MFR • MAN 20 1 REFRIGERATOR 07INIMOTORIZED DAMPER 20 1 1 6 16 17 44.7 45 13 EC EC 20 2 wATER HEATER (ABOVE CEILING) 111:111:11111:111i: $ ''' 1. SPARE 20 HC HC 1 18 19 13 - [ 1_9 111111111E 110111113 Wi en.SERVICE RECEPTACLE 20 1 0_1 0.5 20 21 04 20 1 CONDENSATE PUMP '! ' 1 '' 1" COY/. RECEPTS 20 10_7 2223 04 20 1 BREAK AREA DESK , " iiE PHNOM 1- CONY RECEPTS 20 1 Op 24 25 05 20 1 CAI COUNTDOWN [OFFICE OS iiiiiiiiiiiiiiiiiii „........ iiiiiiiiiiiiiii Ei SPARE „.....:„. 20 1 26 27 0.5 20.1 1 CSSOFFICE IPIIMP03MINK E SPARE, 20 i 28 29 05 20 ILMDAT. OFFICE 0. SPARE 20 I 30 31 05 20 1 MANAGERSOttiCE 0511110111101 Millillililii SPARE 20 1 32 33 0_5 20 I MD OFFICE ,, ,.... . 03gliiiiiiiiiiiii SPARE 20 1 34 35 09 20 1 -..•,••••. DM OFFICE , ,i, ." ..:- ." 09 'SPARE 20 1 36 31 04 20 1 HAL ROOM i 0411110a MiliIiiiiiiiiiii RARE 20 1 jt 30 20 1 SPARE :: .:-' T iii 11111111-iiiii A 20 I 40 41 20 1 ARE, 1111111111111111111 ..1 00 SPARE 20 1 42 TOTAL CONNECTED LOADMH 20.:0 131 172 B P". • 1 II E HID RATED BREAKER._ I suErED TCL FROM TOTAL , CONNECTED LOAD 0.00 : = T = PROVIDE :SWTTCIIINO DUTY RATED BREAKER 1141DICATESTilia cLock" CONTROLLED CIRCUIT 5910 L = LITE DEMAND 125% 41 KVA 0= Fowl:DE A GKEREAKTR. R= RCPT DEMAND 100iYo 1 LE KVA. L = PROVIDE LOCK OFF HANDLE BREAKER, 14 =Mgt DEMAND 125% 3,6 KVA NOTES H -= HVAC DEMAND 100% IF H>C, 06/0,IF H.C: 360 KVA 1. I PROVIDE (2)12(1)#12014D,314" C FOR ALL RANCH CCTSUNLESS STATED OTHERWISE. C =CL DEN1A103 100% IF C>H, 0% IF C<F1 9.0 KVA TOTAL PANEL DEMAND = 516 KVA 2. PROVIDE HACRRATEVBREAKERSON ALL MOTOR LOADS AND 1.00 '3_ PROVIDE LOCKM TYPE BREAICERFORALL LIM:SAFETY 1 * PHA [ S HALL BE r I I 1 -Lt BALANCED . 1 ' 51_6 'KVA NXIIIT LIOHTINGBRANCH CTRCUITS,_ , ! , I 1433 :AMPS TO WITHIN 10% I* I I , F: 1 , 0 NOTE: EQUIPMENT SHOWN FADED AND DASHED IS EXISTING TO REMAIN AND LANDLORD PROVIDED. 2ND FLOOR GRADE ELECTRIC ROOM 'LANDLORD'S SWITCHBOARD' 208/120V, 30,4W 1200A 400AF L TO UTIUTY TRANSFORMER ® ONE LEE DIAGRAM CODED NOTES: r I I I I L MIME MI= FEDEX OFFICE SPACE MEM BASE BUILDING TELEPHONE DISTRIBUTION Mina =MI NM= MEN I I I I I TVSS 30A 30AF PANEL A 208/120V 30,4W 125A MCB 42 POLE PANEL B 206/120V 30,4W 125A MCB 42 POLE 0 PANEL C 208/120V 30,4W 200A MCB 42 POLE TENANT PHONE BOARD GRADE 1. PROVIDE NEW TRANSIENT VOLTAGE SURGE SUPPRESSOR. TVSS SHALL BE WIREMOLD "ZONEM ASTER", MODEL #ZA120Y). COORDINATE WITH FEDEX OFFICE PROJECT MANAGER ON SITE. 2. PROVIDE NEW 240V, 400A/3P/400AF SWITCH LOCATED IN LANDLORD'S SWITCHBOARD. PROVIDE NAME PLATE AT SWITCH TO READ "FEDEX OFFICE". VERIFY EXACT LOCATION AND REQUIREMENTS IN FIELD. 3. PROVIDE NEW METER BASE AND ALL ASSOCIATED CURRENT TRANSFORMERS. E.C. SHALL CONTACT LOCAL UTILITY COMPANY TO ARRANGE FOR INSTALLATION OF NEW ELECTRIC METER AND TO ARRANGE ELECTRICAL SERVICE IN FEDEX OFFICE'S NAME. PROVIDE NAME PLATE AT METER TO READ "FEDEX OFFICE". VERIFY EXACT LOCATION AND REQUIREMENTS IN FIELD. 4. PROVIDE 208/120V, 30, 4W, 125A M.C.B. ELECTRIC PANEL 'A'. SEE SCHEDULE FOR REQUIREMENTS. 5. PROVIDE 208/120V, 30, 4W, 125A M.C.B. ELECTRIC PANEL 'B'. SEE SCHEDULE FOR REQUIREMENTS. 6. PROVIDE 208/120V, 30, 4W, 200A M.C.B. ELECTRIC PANEL 'C'. SEE SCHEDULE FOR REQUIREMENTS. 7. PROVIDE (4)#1/0, (1)#1/0 GND (GROUNDING IN ACCORDANCE WITH TABLE 250.122)IN 2-1/2" CONDUIT. IN ACCORDANCE WITH NEC 240.21B, FEEDER TAPS SHALL BE LESS THAN 10' IN LENGTH. 8. PROVIDE (4)#3/0, (1)#1/0 GND (GROUNDING IN ACCORDANCE WITH TABLE 250.122)IN 2-1/2" CONDUIT. IN ACCORDANCE WITH NEC 240.21B, FEEDER TAPS SHALL BE LESS THAN 10' IN LENGTH. 9. PROVIDE (4)#500 KCMIL, (1)1/1/0 GND IN 4" CONDUIT. 10. PROVIDE 2" CONDUIT (WITH PULL STRING) FROM TELEPHONE DISTRIBUTION TO NEW TELEPHONE BOARD IN TENANT SPACE. 11. PROVIDE (3)#8, (1)#8 GND (GROUNDING IN ACCORDANCE WITH TABLE 250.122) IN 1" CONDUIT. IN ACCORDANCE WITH NEC 240.21B, FEEDER TAPS SHALL BE LESS THAN 10' IN LENGTH. 12. PROVIDE NEW 30A/3P/30AF, NEMA -1, HEAVY DUTY DISCONNECT FOR NEW TVSS. COORDINATE EXACT LOCATION AND REQUIREMENTS IN FIELD. 13. PROVIDE NEW 8" X 8" X 72" WIREWAY AS REQUIRED. 14. PROVIDE BUTT SPLICE/FEEDER TAPS FOR CONNECTIONS TO INCOMING FEEDERS. FEEDER TAPS SH ALL BE IN ACCORDANCE WITH NEC 240.21B. ONE -LINE DIAGRAM ONE ME DIAGRAM GENERAL NOTES A. PARALLEL FEEDER CONDUCTORS SHALL BE CUT TO EXACTLY THE SAME LENGTHS AND SHALL BE FROM THE SAME FACTORY RUN. ALL CONNECTIONS FOR SAME SHALL BE TORQUED TO IDENTICAL VALUES. B. EXTERIOR ELECTRICAL WORK SHALL NOT ONLY BE WEATHERPROOF AND WATER -TIGHT, BUT SHALL ALSO BE RUST -RESISTANT. C. CONDUCTORS BELOW GRADE OR SUBJECT TO MOISTURE SHALL BE "XHHW-2". D. PROVIDE FACTORY SERIES COORDINATION FOR ALL CIRCUIT BREAKERS (INCLUDING ALL BRANCH BREAKERS), RELATIVE TO "UPSTREAM" BREAKERS, SO THAT ONLY THE BREAKER CLOSEST IN THE CIRCUIT TO THE LOAD TRIPS UPON AN OVERLOAD OR FAULT CONDMON. E. POWER DISTRIBUTION EQUIPMENT SUPPUER SHALL PROVIDE EQUIPMENT APPROPRIATELY RATED AND BRACED TO ACCOMMODATE THE AVAILABLE FAULT CURRENT AT THE UTILITY COMPANY TRANSFORMER SECONDARIES. THIS SUPPLIER SHALL ACCORDINGLY PROVIDE ANY RELATED CALCULATIONS SO THAT THEIR EQUIPMENT IS PROPERLY COORDINATED FOR THE AVAILABLE FAULT CURRENT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THIS SUPPUER WITH COPIES OF THE ELECTRICAL DOCUMENTS AS REQUIRED SO THAT PROPERLY RATED/BRACED EQUIPMENT IS PROVIDED UNDER BASE BID. F. GROUNDING ELECTRODE CONDUCTORS SHALL BE PROVIDED IN STRICT COMPLIANCE WITH N.E.C., INCLUDING N.E.C. ARTICLE 250 AND TABLE 250-66. THESE CONDUCTORS MAY NOT BE INDICATED ON RISERS OR SINGLE-UNES, BUT SHALL BE PROVIDED UNDER BASE BID NEVERTHELESS. G. EQUIPMENT GROUNDING CONDUCTORS SHALL BE PROVIDED IN STRICT COMPLIANCE WITH N.E.C., INCLUDING N.E.C. ARTICLE 250 AND TABLE 250-122. THESE CONDUCTORS MAY NOT BE INDICATED ON RISERS OR SINGLE -LINES, BUT SHALL BE PROVIDED UNDER BASE BID NEVERTHELESS. H. WORKING CLEARANCES SHALL BE PROVIDED FOR ALL ELECTRICAL EQUIPMENT (SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, STARTERS, DISCONNECTS, ETC. AS APPUCABLE) IN STRICT COMPLIANCE WITH N.E.C. CHAPTER 1, PART B, SECTION 110-26(a). LOCATIONS SHOWN ON FLOOR PLANS ARE SCHEMATIC AND DIAGRAMMATIC IN NATURE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPLIANCE WITH THE ABOVE N.E.C. REFERENCE. THIS REQUIREMENT APPLIES TO EQUIPMENT ON FLOOR PLANS AS WELL AS TO EQUIPMENT SHOWN ON RISER. I. HOLD ALL NEW OVERHEAD ELECTRICAL WORK AS TIGHT AS POSSIBLE TO THE BOTTOM OF THE OVERHEAD STRUCTURE. LOCATE ANY RELATED PULLBOXES SO THAT THEY WILL BE FULLY ACCESSIBLE AFTER ALL CONSTRUCTION WORK IS COMPLETE. AS WITH ALL WORK, COORDINATE IN ADVANCE WITH ALL OTHER TRADES. J. ROUTE FEEDER CONDUITS BELOW GRADE WHEREVER POSSIBLE. VERY LIMITED SPACE EXISTS ABOVE ACOUSTICAL TILE CEILINGS AND MANY, IF NOT MOST, OF THE SPACE ABOVE THE GYPSUM BOARD CEILINGS IS NOT AVAILABLE FOR RUNNING CONDUIT. STUDY ALL ARCHITECTURAL, STRUCTURAL & MECHANICAL DRAWINGS VERY CAREFULLY BEFORE LAYING OUT FEEDER ROUTES. K. ALL PANELS HAVE NEMA 1 ENCLOSURES UNLESS NOTED OTHERWISE. L ALL PANELS ARE SURFACE MOUNTED UNLESS NOTED OTHERWISE. M. E.C. SHALL BE RESPONSIBLE FOR BALANCING ALL PHASES TO WITHIN 10%. SCALE NOT TO SCALE i'LNANT ELECTRIC LOAD SUMMARY FURNISHED BY DESCRIPTION N_E_C_ CONNECTED kW VOLTAGE MULTIPLIER PER N.E.C. N.E.C. DEMAND kW LIGHTLNG 8.1 120 1.25 10.1 SIGNACE 1.2 120 125 13 EQUIPMENT RECEPTACLES 74.9 120 1.00 74.9 e•--..--..e--se-se-v--.."-- 'WATER HEATER 2.5 208 1.25 3.1 :HVAC EQUIPMENT 36_0 480 - 1.00 36.0 'MIK_ EQUIPMENT 1.5 120 1.25 19 TOTAL 1242 FEEDER AMPERAGE AMPS CP CORD AND PLUG CONNECTION 127.5 : NEC DEMAND kW x 1000 = MININIUM 3543 ISADEQUATE 4 SYSTEM VOLTAGE x 133 127.5 kW k 1000 = , o 208x 133 ,THEREFORE. inE 400 AMP SERVICE Fl CTRICAL RESPONSELITY EXISTING FURNISHED BY INSTALLED BY REMARKS SCHEDULE LANDLORD FEDEX OFFICE TENANT CONTRACTOR OTHERS et 0 z-J (21 FEDEX OFFICE TENANT CONTRACTOR OTHERS MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRIC ROOM MG MAGNETIC STARTER OR CONTACT BAS BUILDING AUTOMATION SYSTEM CN CONTROLS • MS MANUAL STARTER LOW LOW VOLTAGE CONTROLS : TS TOGGLE SWITCH • VFD VARIABLE FREQUENCY DRIVE LINE LINE VOLTAGE CONTROLS SERVICE ENTRANCE CONDUIT TO LEASE SPACE MFR MANUFACTURER MSR MANUAL STARTER W/CONTROL RELAY RUNE REVERSE ACTING UNE VOLTAGE STAT • PC PLUMBING CONTRACTOR OV OVERCURRENT PROTECTION CNFVAPSit YPUITLE6A1W1:72INCE:1N8D- MAN MANUAL ( wEII • OR OWNER OR OTHERS SERVICE ENTRANCE FEEDERS TO LEASE SPACE MCA MINIMUM CIRCUIT AMPACITY A • CP CORD AND PLUG CONNECTION • MARK DESCRIPTION METER REQUIREMENTS PH ASE EMERG BHP • HTG KW WATTS FLA • OCP DC FURN LIGHT FIXTURES AND LAMPS L.N....."........-"..............-..................".-.".....w.-.- DC WIRE MC TYPE • MC INST ........".-.."....."...."...."....w.-.....-"-..".....".....A.-."....."..-".-."-1 CN TYPE CN FURN • 1 OUTLETS AND SWITCHES AIR COND. UNIT 208 3 • • 62 GENERAL CONDUIT & WIRING EC EC EC • MFR MFR MFR • H C FIC°N TELEPHONE CONDUIT W/ PULL WIRE 1 CP -1 CONDENSATE PUMP • 1 • TELEPHONE CABLING EC EC • CS EC EC • BAS TELEPHONE EQUIPMENT HC HC 0 CU -1 • 208 1 • P.O.S. DATA CONDUIT ' 22.1 • EC EC EC • MFR REFER TO SHEET DC -1 P.O.S. DATA CABLING LOW HC HC HC • EF -1 EXHAUST FAN 120 • TENANT'S 208 VOLT PANEL "A" 38 • MFR • MFR MG TENANT'S 208 VOLT PANEL "B" MFR MFR MAN • EC EC 0 • EXHAUST FAN 120 TENANT'S 208 VOLT PANEL "C" • 38 0.5 • MFR MFR FIRE ALARM SYSTEM ', MG MFR MFR • MAN EC EC • 0 FC -1 HVAC ELECTRICAL COORDINATION SCHEDULE (HECS) hal Ti ABBREVIATIONS CONTRACTOR TYPE MOTOR CONTROL TYPE CONTROL TYPE GI IRNC DC LOCAL DISCONNECT EC ELECTRICAL CONTRACTOR CS COMBINATION STARTER TC TIMECLOCK NEI NEvRl MC MOTOR CONTROL (POWER) EX EXISTING MCC MOTOR CONTROL CENTER CPT CONTROL POWER TRANSFORMER SD DUCT SMOKE DETECTOR FC FIRE PROTECTION CONTRACTOR MG MAGNETIC STARTER OR CONTACT BAS BUILDING AUTOMATION SYSTEM CN CONTROLS GC GENERAL CONTRACTOR MS MANUAL STARTER LOW LOW VOLTAGE CONTROLS : TS TOGGLE SWITCH HC HVAC CONTRACTOR VFD VARIABLE FREQUENCY DRIVE LINE LINE VOLTAGE CONTROLS C/B H.A.C.R. CIRCUIT BREAKER AT SOURCE PANELBOARD MFR MANUFACTURER MSR MANUAL STARTER W/CONTROL RELAY RUNE REVERSE ACTING UNE VOLTAGE STAT FUSE FUSE AT LOCAL DISCONNECT (VERIFY FIELD RATING) PC PLUMBING CONTRACTOR OV OVERCURRENT PROTECTION CNFVAPSit YPUITLE6A1W1:72INCE:1N8D- MAN MANUAL ( wEII FLA OPERATING FULL LOAD AMPS OR OWNER OR OTHERS sCi FA FIRE ALARM 4-9 ND MCA MINIMUM CIRCUIT AMPACITY A CO CARBON MONOXIDE SENSOR 32 11 1 - - CP CORD AND PLUG CONNECTION INT INTEGRAL TO EQUIPMENT MARK DESCRIPTION VOLTS PH ASE EMERG BHP HP HTG KW WATTS FLA MCA OCP DC FURN DC INST DC WIRE MC TYPE MC FURN MC INST MC WIRE CN TYPE CN FURN S Q U AN ACU -1 AIR COND. UNIT 208 3 62 80 EC EC EC MG MFR MFR MFR LOW H C FIC°N HC 1 CP -1 CONDENSATE PUMP 120 1 1/10 3.5 EC EC EC CS EC EC EC BAS HC HC HC 0 CU -1 CONDENSING UNIT 208 1 22.1 35 EC EC EC MG MFR MFR MFR LOW HC HC HC 0 EF -1 EXHAUST FAN 120 1 38 0.5 MFR MFR MFR MG MFR MFR MFR MAN EC EC EC 0 EF -2 EXHAUST FAN 120 1 38 0.5 MFR MFR MFR MG MFR MFR MFR MAN EC EC EC 0 FC -1 FANCOIL UNIT 208 1 6 44.7 45 EC EC EC MG MFR MFR MFR LOW HC HC HC 1 EL3' osbl RECEIVED CITY OF TUKVVILA RE\IISIONN01-1_ AUG 1 3 2013 PERMIT CENTER ARCHITECT kA 18200 VON KARMAN AVE I SUITE 910 IRVINE, CA I 92612 t 949.705.0700 I f 949.705.0701 MulvannyG2.com KOHRS LONNENIAM HEL ENGINEERS, PSC MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 Fr. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX ARCHITECTURAL PROJECT NO.: MEP PROJECT NO.: STRUCTURAL PROJECT NO.: CIVIL PROJECT NO.: 12-0253-01A 12622.00 116 ANDOVER PARK EAST SEATTLE, WA 98188 CENTER NO.: SITE ID NO: 5173 989630 PROGRAM: RELO STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SEATTLE, WA 98188 CONTEMPORANEOUSLY WITH ITS ISSUE DATE 04.26.2013 AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS and ENGINERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND IS CONTRARY TO THE LAW. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF KINKO'S INC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH FEDEX KINKO'S. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. FEDEX KINKO'S IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS - SUCH BY GOVERNING AUTHORITIES. PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: /1\ CN 1- BLDG COMMENTS 07/11/13 /4\ CN 2- FXO COMMENTS 07/11/13 ACN 3- FXO COMMENTS 07/28/13 ACN 4- FXO COMMENTS 08/01/13 ACN 5- BLDG & MECH COMMENTS 08/09/13 A AA / \ A A A A PERMIT SET ISSUE DATE: BID SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: 05.31.13 04.26.13 DRAWING TITLE: ELECTRICAL DETAILS & SCHEDULES DRAWING NUMBER: E-3.0 (C-2,4,6) W/P GFI (c--20) " „ +78" +78" +30 +90" WP POWPR DISCONNECT SWITCH (FUSED) LIQUIDTIGHT FLEXIBLE CONDUIT (1 '-0"MAX.LG.) RTU OR CONDENSING UNIT FULL PERIM ROOFTOP EQUIPMENT CURB OR CONDENSING UNIT RAIL N 77. ROOFING r � � 5/8" POWERSTRUT WP LIGHT FIXTURE CROUSE -HINDS CAT.#VXFH25G OR EQUAL 100W RIGID CONDUIT -SIZE AS REQUIRED WP LIGHT SWITCH WP RECEPTACLE POWER & CONTROL CONDUIT ROOF TO BE ROUTED THRU ROOF IN APPROVED OPENEINGS IN RTU CURBS. EXISTING JOIST ROOFTOP EQUIPMENT DETAIL (C-14,16,18) W/P GFI (C-20) SCALE NOT TO SCALE 0 POWER CODED NOTES 1. PROVIDE NEW BUCK BOOST TRANSFORMER AS REQUIRED. REFER TO EQUIPMENT MANUAL AND FIELD VERIFY EXACT REQUIREMENTS. 2. STOREFRONT WINDOW RECEPTACLE MOUNTED IN CEILING SHALL BE CONTROLLED THROUGH TIMECLOCK. COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS FOR EXACT SIGN LOCATION. 3. RUN MC CABLE, FLEX CONDUIT THROUGH TOE SPACE. COORDINATE WITH FURNITURE MANUFACTURER REPRESENTATIVE. 4. PROVIDE A WIREMOLD ALA4800 SERIES TWO-PIECE, MULTIPLE CHANNEL, LARGE PROFILE ALUMINUM RACEWAY, FLOOR MOUNTED WHERE SHOWN ON THIS SHEET. ONE CHANNEL FOR POWER, THE OTHER CHANNEL FOR DATA. CONTACT GRAYBAR FOR ALL REQUIRED ACCESSORIES. CONTACT PAUL SICKMAN WITH GRAYBAR AT (817) 213-1200. 5. ISOLATED CIRCUIT FOR COMPUTER WORKSTATION FURNITURE. (ISOLATED GROUND AND NEUTRAL CONDUCTORS). 6. PROVIDE TWO GANG, WALL MOUNTED JUNCTION BOX AT 8" A.F.F. IN A CONCEALED SPACE AT ONE END OF THE FURNITURE FOR POWER AND DATA CONNECTIONS TO FURNITURE. PROVIDE DEVICES WHERE SHOWN AND UTILIZE FLEXIBLE "WHIP" CONDUITS THROUGH TOE -SPACE. ROUTE CONDUITS TO WALL, UP WALL TO ABOVE ACCESSIBLE CEILING. REFER TO SHEET DC -1.0 FOR INFORMATION ON DATA. 7. PROVIDE 240V, 30A/2P/NF DISCONNECT SWITCH FOR WATER HEATER HIGH ON WALL NEAR MOP SINK. PROVIDE (2)#12, (1)#12 GND IN 3/4" CONDUIT. SEE PLUMBING DRAWING AND COORDINATE EXACT LOCATION. 8. ALL RECEPTACLES SHALL BE STANDARD NEMA 5-20R UNLESS SPECIFICALLY MARKED OTHERWISE. 9. PROVIDE NEW ADDRESSABLE DUCT MOUNTED SMOKE DETECTOR COMPATIBLE WITH EXISTING BASE BUILDING FIRE ALARM SYSTEM. MECHANICAL CONTRACTOR SHALL INSTALL SMOKE DETECTOR IN THE SUPPLY AND RETURN AIR DUCT. MECHANICAL CONTRACTOR SHALL PROVIDE WIRING TO FAN INTERLOCK. E.C. SHALL PROVIDE WIRING FOR FINAL CONNECTION TO REMOTE TEST ANNUNCIATOR AND BASE BUILDING FIRE ALARM SYSTEM. SEE NOTE 14. 10. PROVIDE 2'W x 4'H x 3/4"TH PLYWOOD EQUIPMENT BOARD. REFER TO ELEVATION DETAILS ON SHEET A4.0 AND/OR A4.1. E.C. SHALL PROVIDE 2" TELEPHONE CONDUIT AND PULL STRING FROM LANDLORD'S TELEPHONE DISTRIBUTION LOCATION TO NEW TELEPHONE EQUIPMENT BOARD. FIELD VERIFY EXACT LOCATION. COORDINATE WORK OUTSIDE OF TENANT SPACE WITH LANDLORD. 11. PROVIDE TWO GANG, SURFACE MOUNTED JUNCTION BOX. AT IN A CONCEALED SPACE AT ONE END OF THE FURNITURE FOR POWER AND DATA CONNECTIONS TO FURNITURE. PROVIDE DEVICES WHERE SHOWN AND UTILIZE FLEXIBLE "WHIP" CONDUITS THROUGH TOE -SPACE. 12. PROVIDE SEPARATE CONDUITS (1" MINIMUM) FOR POWER AND DATA AS REQUIRED TO ACCOMMODATE POWER AND DATA REQUIREMENTS SHOWN ON PLAN. MULTIPLE CONDUITS ARE INTENDED TO SHARE ONE TRENCH. THE E.C. SHALL EMPLOY PROPER INSTALLATION MEANS AND METHODS AS REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. NOTE: ONLY ONE CONDUIT SHOWN FOR ROUTING PURPOSES. 13. PROVIDE REMOTE TEST ANNUNCIATOR FOR ROOFTOP UNIT DUCT SMOKE DETECTOR. REFER TO ELECTRIC SPECIFICATIONS ON SHEET E-4.0 FOR MORE INFORMATION. 14. PROVIDE A HUBBELL #PFBRG1 (SINGLE GANG), #PFBRG2 (TWO GANG) OR #PFBRG3 (THREE GANG) NONMETALLIC FLOOR BOX WHERE SHOWN AND INDICATED ON THIS SHEET. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL APPROPRIATE TRIM -RINGS AND COVERPLATES. 15. NEW EXHAUST FAN SHALL BE CONNECTED TO THE SAME BRANCH CIRCUIT FEEDING THE RESTROOM LUMINAIRES AND INTERLOCK WITH OCCUPANCY SENSORS. 16. PROVIDE 240V 60A/3P/NF, NEMA -3R. HEAVY DUTY DISCONNECT SWITCH FOR NEW AIR CONDITIONING UNIT (ACU). REFER TO HVAC/ELECTRICAL COORDINATION SCHEDULE AND PANEL SCHEDULES ON SHEET E-3.0 FOR ALL INFORMATION AND REQUIREMENTS ON THIS EQUIPMENT. 17. PROVIDE JUNCTION BOX AND LOCAL DISCONNECT SWITCH FOR NEW MOTORIZED DOOR. COORDINATE EXACT REQUIREMENTS WITH THE DOOR CONTRACTOR PROJECT MANAGER. 18. PROVIDE WEATHER PROOF GFI SERVICE RECEPTACLE FOR AIR CONDITIONING UNIT (ACU). 19. PROVIDE 120V CONNECTION FOR RE -CIRCULATION PUMP AS REQUIRED. SEE PLUMBING DRAWING AND COORDINATE EXACT LOCATION. 20. PROVIDE 240V 100A/3P/NF, NEMA -3R. HEAVY DUTY DISCONNECT SWITCH FOR NEW AIR CONDITIONING UNIT (ACU). REFER TO HVAC/ELECTRICAL COORDINATION SCHEDULE AND PANEL SCHEDULES ON SHEET E-3.0 FOR ALL INFORMATION AND REQUIREMENTS ON THIS EQUIPMENT. 21. PROVIDE 240V 30A/3P/NF, NEMA -3R. HEAVY DUTY DISCONNECT SWITCH FOR NEW AIR CONDITIONING UNIT (ACU). REFER TO HVAC/ELECTRICAL COORDINATION SCHEDULE AND PANEL SCHEDULES ON SHEET E-3.0 FOR ALL INFORMATION AND REQUIREMENTS ON THIS EQUIPMENT. 22. PROVIDE FIRE ALARM DEVICES AS SHOWN. E.C. SHALL VERIFY THAT ALL DEVICES MEET ALL APPLICABLE CODES AND THAT THEY MATCH THE BASE BUILDING FIRE ALARM SYSTEM. ALL FINAL CONNECTIONS TO THE BASE BUILDING FIRE ALARM SYSTEM SHALL BE BY THE LANDLORD'S FIRE ALARM CONTRACTOR AT THE TENANT'S EXPENSE. REFER TO ELECTRIC SPECIFICATIONS ON SHEET E-4.0 FOR MORE INFORMATION. COORDINATE IN FIELD WITH LANDLORD. 23. PROVIDE WEATHER PROOF GFI SERVICE RECEPTACLE AND LIGHT FOR ROOFTOP UNIT. SEE DETAIL 1 ON THIS SHEET FOR MORE INFORMATION. ELECTRICAL POWER PLAN SCALE: 1/4" = 1'-0" A 75cd III 111 I1 II "''r'�rr 11,0 r " �"ud"7""d"I° ✓ d I (C-22) C-5) (c-3) (C-1 BREAK HANDLING 122 HAL ROOM TS 123 Ts Ts r"'""°da�� ,rr''''""r'�i.r ; ✓r7 77 °,d"yd,, J; �,✓d,e u✓ 7" "; ;7 POWER GENERAL NOTES A. ALL CONDUIT SHALL BE 3/4" DIAMETER, UNLESS OTHERWISE NOTED. B. CONTRACTOR TO VERIFY EXACT LOCATION OF ALL OUTLETS WITH ARCHITECTURAL DRAWINGS AND FIELD COORDINATE PRIOR TO ANY WORK. C. VERIFY EXACT LOCATIONS AND NEMA CONFIGURATIONS OF ALL EQUIPMENT AND PLUGS AND PROVIDE THE PROPER RECEPTACLE TO MATCH. D. ALL BRANCH CIRCUITS SHALL CONTAIN A COPPER EQUIPMENT GROUNDING CONDUCTOR SIZED PER CODE REGARDLESS OF CONDUIT TYPE. E. ALL RECEPTACLES SHALL BE MOUNTED AT +17" TO CENTER OF BOX UNLESS OTHERWISE NOTED. F. PROVIDE DEDICATED OR SEPARATE CONDUITS FOR ALL POS DATA LINES. (DO NOT SHARE WITH OTHER PHONE OR DATA LINES.) - G. CONTRACTORS TO VERIFY EXACT LOCATION OF FLOOR OUTLETS AND CONDUIT ROUTING WITH TENANT PRIOR TO SAW -CUTTING ANY PART OF THE FLOOR. FILL AND PATCH TO MATCH EXISTING FLOOR. H. PROVIDE CONDUIT AND BOX FOR ALL DATA . COMMUNICATIONS DEVICES, HOWEVER PROVIDE DEDICATED OR SEPARATE CONDUITS FOR ALL POS -DATA LINES (DO NOT SHARE WITH OTHER TELEPHONE OR DATA LINES). REFER TO SHEET DC -1 FOR EXACT LOCATIONS. ALL EQUIPMENT AND CABLE SHALL BE FURNISHED AND INSTALLED BY OTHERS. - I. ALL FLOOR OUTLETS SHALL BE FLUSH MOUNTED.. J. PROVIDE NAME PLATE FOR ALL EQUIPMENT OUTLETS INDICATING CIRCUIT NO/OUTLET RATING/EQUIPMENT TO BE CONNECTED -- VERIFY ALL EQUIPMENT WITH PROJECT MANAGER. K. ALL OUTLETS SHALL BE PERMANENTLY LABELED WITH THE PANEL AND CORRESPONDING CIRCUIT NUMBER. THE LABEL SHALL BE A TYPEWRITTEN, STICK -ON LABEL, AND PLACED ON THE OUTSIDE OF THE COVER PLATE. L STUB -UP (2) 3/4" CONDUITS AT +6" ABOVE ACCESSIBLE CEILING FROM EACH PANELBOARD FOR FUTURE USE. M. STUB -UP (3) 1/2" CONDUITS FROM BACKBOARD AT +6" ABOVE ACCESSIBLE CEILING. ONE EACH FOR TELEPHONE, DATA, AND POINT OF SALE. N. ALL PLYWOOD MOUNTED ON WALL FOR ELECTRIC AND DATA PURPOSES SHALL BE PAINTED WITH FIRE RETARDING PAINT. 0. ANY PENETRATIONS THROUGH FIRE RESISTANT/RETARDANT WALLS, PARTITIONS, FLOORS AND CEILINGS SHALL BE FIRE STOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING.. P. FOR DEMISING WALLS, CONTRACTOR SHALL MAINTAIN A 24" HORIZONTAL SEPARATION BETWEEN TENANT'S NEW DEVICES AND ADJACENT TENANT'S DEVICES. VERIFY EXACT LOCATION OF ADJACENT TENANT'S DEVICES IN FIELD. Q. PLEASE REFER TO SHEET DC -1 FOR ALL' TELEPHONE AND DATA LOCATIONS AND REQUIREMENTS. R. E.C. SHALL X-RAY FLOOR PRIOR TO ALL, TRENCHING. COORDINATE WITH THE LANDLORD ON SITE FOR EXACT REQUIREMENTS. n.� �7"""�" dim 77.7a77,77,7 - (B v _ _ . ...... _ PACK & SHIP )I ;,Illµ- I I 124 7 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. (B-1,33) (B-7;9,11 -13,15,17) RETAIL (C-13) 75cd (C-25) (C-23) (C-15) B-20 22,24,26) 2) (B-24,26,28) 2 GANG (1)NEMA 6-15R (B-30,32) 1 GANG NEMA L6-3OR (2)#10, (1)#10 GND (B-20,22) 2 GANG NEMA 6-20R ENHANCED PACK & SHIP SEPARATE PERMIT REQUIRED FOR: (ilechanical 0 Electrical QPPlumbing [Peas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. MITE: ,-a,evlsers will require a new plan submittal and may include additional plan reviewfee_ FILE COPY Permft 3DOS`% ARCHITECT 18200 VON KARMAN AVE I SUITE 910 IRVINE, CAI 92612 t 949.705,0700 I f 949.705,0701 Mu,IVa nyG2 corn 77111171 Ple.i rr iew approval is subject to errors and orris s. ....� of construction documents does not authorize o; art adopted code or ordinance. Receipt Lpproved '. Copy and wagons is admow ed: By - Date: City Of Tbkwila BUILDING DIVISION (C-21) /CASH/ COUNTDOWN 119 EXPIRES FEB 0 2 2014 J 47 13 L KOHRS LONNEMANN HEIL ENGINEERS, PSC MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE. SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX ARCHITECTURAL PROJECT NO.: MEP PROJECT NO.: STRUCTURAL PROJECT NO.: CIVIL PROJECT NO.: 12-0253-01 A I 12622.00 CENTER NO.: SITE ID NO: 5173 989630 F- W 00 CC co Q 00 CC W Q > O 0 w J Z I -- Q � V J PROGRAM: RELO CSS OFFICE (B-14,16,18) 2 GANG 1)NEMA 6-15R (B-2,4,6) (B-8,10,12) (B,1 --I 14,16,18) (B-10,12) 3 GANG (B-4,6) 3 GANG (B-2) 2 GANG (C-24) DM, OFFIOI, 121 -may 1, 43!) 1.-..I ENTRY (B-33) 1 GANG iVID ASS'T, OFFICE J 5 (B-31) 1 GANG 14 (A-33) 1110c (A-27) STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SEATTLE, WA 98188 CONTEMPORANEOUSLY WITH ITS ISSUE DATE 04.26.2013 AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS and ENGINERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND IS CONTRARY TO THE LAW. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF KINKO'S INC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH FEDEX KINKO'S. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. FEDEX KINKO'S IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. 4E, . __....1 (A-10) 2 GANG PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: ISSUED FOR PERMIT 05.10.13 SIGNS & GRAPHICS 113 NAGER'S OFFICE MD OFFICE (B-25) (B-27,29) •u . • 1 •IUII1 (B-23) l (B-21) (B -f19 SELF-SERVICE AREA (A-12,14) 3 GANG REVIEWED. FOR COMPLIANCE WITH NFPA 70 - NEC JUN 18 2013 City of Tukwlla BUILDING DIVISION 11111411 (A-24) 2 GANG WOME S REST' SOM MEN REST'OOM (A-10,12,14) COMPUTER SERVICES (C-8,10,12) (C-20) RECEIVED CITY OF TUKWILA PERMIT SET ISSUE DATE: BID SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: 04.26.13 05.10.13 A-16,18,20) (A-22,24) -.._ Iii e.� L -_II►. II) I J O JUN 1 1 2013 DRAWING TITLE: PERMIT CENTER ELECTRICAL POWER PLAN SII_ ....00111>_ - _ ....0111111111110.._ W{/////r//!/./Jf/+//JIIl/l./1+.///l/rr�Tllll�rrl/!/Jlfr'f!''.fif/rfr%hl,+,'%'/./,t/�I/+Jl/.LP1,+rflfi+i/,Or 05#.+/.f�+". &%:0T.�-4, / ,// /, ADJACENT LEASE SPACE NOT PART OF WORK , II, ON ROOF DRAWING NUMBER: or el 010 EL BO5 !� � I l v (A-10) 2 GANG PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: ISSUED FOR PERMIT 05.10.13 SIGNS & GRAPHICS 113 NAGER'S OFFICE MD OFFICE (B-25) (B-27,29) •u . • 1 •IUII1 (B-23) l (B-21) (B -f19 SELF-SERVICE AREA (A-12,14) 3 GANG REVIEWED. FOR COMPLIANCE WITH NFPA 70 - NEC JUN 18 2013 City of Tukwlla BUILDING DIVISION 11111411 (A-24) 2 GANG WOME S REST' SOM MEN REST'OOM (A-10,12,14) COMPUTER SERVICES (C-8,10,12) (C-20) RECEIVED CITY OF TUKWILA PERMIT SET ISSUE DATE: BID SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: 04.26.13 05.10.13 A-16,18,20) (A-22,24) -.._ Iii e.� L -_II►. II) I J O JUN 1 1 2013 DRAWING TITLE: PERMIT CENTER ELECTRICAL POWER PLAN SII_ ....00111>_ - _ ....0111111111110.._ W{/////r//!/./Jf/+//JIIl/l./1+.///l/rr�Tllll�rrl/!/Jlfr'f!''.fif/rfr%hl,+,'%'/./,t/�I/+Jl/.LP1,+rflfi+i/,Or 05#.+/.f�+". &%:0T.�-4, / ,// /, ADJACENT LEASE SPACE NOT PART OF WORK , II, ON ROOF DRAWING NUMBER: or el 010 EL BO5 !� � ® LIGHTING CODED NOTES 1. PROVIDE WALL MOUNTED, DUAL RELAY, MOTION OCCUPANCY SENSOR LIGHTING CONTROL MADE BY 'WATT STOPPER', MODEL #PW -200. RELAYS SHALL BE SET TO "MANUAL ON" AND "AUTO OFF". 2. PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN CONCEALED LOCATION AND MAKE ALL FINAL CONNECTIONS FOR 120 VOLT SIGN FURNISHED BY TENANT. COORDINATE EXACT LOCATIONS WITH TENANT'S CONSTRUCTION MANAGER. WIRE THROUGH PHOTOCELL. MOUNT PHOTOCELL ON ROOF ABOVE ENTRANCE. 3. CONNECT TO SWITCH "a" & "b". 4. CONNECT TO SWITCH "c" & "d". 5. CONNECT TO SWITCH "e" & "f". 6. CONNECT TO SWITCH "g" & "h". 7. CONNECT TO SWITCH "1" & 8. CONNECT TO SWITCH "k" & "I". 9. CONNECT TO SWITCH "m" & "n". Rif 10. 11. 12. 13. 14. EXTERIOR EGRESS LIGHTING IS PROVIDED AND POWERED BY LANDLORD UNDER A SEPARATE CONTRACT. LIGHT FIXTURES LABELED "EM" CONTAIN 90 MINUTE BATTERY BACK-UP FOR EMERGENCY EGRESS ILLUMINATION. MASTER SWITCHBANK LOCATION. PROVIDE NEW TIMECLOCK 'TC' AND NEW LIGHTING CONTACTORS 'LC1' & 'LC2'. REFER TO LIGHTING CONTACTOR SCHEDULES ON THIS SHEET AND SPECIFICATIONS ON THIS SHEET FOR ADDITIONAL INFORMATION. TIMECLOCK SHALL BE DIGITAL, 365 -DAY SKIPPER TYPE WITH HOLIDAY PROGRAMMING AND WITH EXTERNAL OVERRIDE CAPABILITIES (TORK, PARAGON, OR ACCEPTED EQUIVALENT). COORDINATE ON/OFF SCHEDULING WITH FEDEX OFFICE PROJECT MANAGER. PROVIDE 2 -HOUR OVERRIDE TIME SWITCH EQUAL TO INTERMATIC FF SERIES. OVERRIDE SWITCH SHALL SERVE AS THE EXTERNAL OVERRIDE SIGNAL TO TIMECLOCK 'TCI' POLE #1. PROVIDE PRINTED LABEL AT SWITCH LOCATION TO READ "OVERRIDE SWITCH". REFER TO LIGHTING CONTACTOR SCHEDULES, LIGHTING CONTROL DETAIL, AND SWITCH BANK DETAIL 1 ON THIS SHEET FOR ADDITIONAL INFORMATION. UGHTING GENERAL NOTES A. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL LIGHTING BRANCH CIRCUITS SHALL BE PROVIDED WITH (2)#12 AND (1)#12 GND IN 3/4" CONDUIT FOR EACH 20 AMP CIRCUIT. B. EMERGENCY AND EXIT FIXTURES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. C. EMERGENCY FIXTURES, EMERGENCY BATTERY BALLASTS SHALL BE PROVIDED WITH AN UNSWITCHED "HOT" TO PROVIDE CONTINUOUS POWER TO BALLAST EVEN WHEN FIXTURE IS SWITCHED OFF. D. ALL NIGHT LIGHTS (SHOWN WITH "NL" DESIGNATION) SHALL BE WIRED AHEAD OF SWITCHING. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. (A-19,21,23) X1 A10 (A-13) CASH/ COUNTDOWN CSS OFFICE 117711 17 MD ASST. OFFICE Al 0 A20 2 HOUR OVERRIDE TIMER SWITCH TO CONTROL TIMECLOCK POLE #1 - LC1 PANEL A -0 - O O -0 0 ® DETAL NOTES 1. REFER TO CONTACTOR SCHEDULE LC1 ON THIS SHEET FOR CIRCUITS TO BE CONNECTED TO CONTACTOR. 2. REFER TO TIMECLOCK SCHEDULE ON THIS SHEET FOR CIRCUITS TO BE CONNECTED TO TIMECLOCK. SWITCHES "a - n" rf GENERAL LIGHTING )LIGHTING CONTROL SCHEMATIC SCALE: NONE LIGHTING CONTROL DESIGN INTENT STOREFRONT RECEPTS EVENT: NORMAL BUSINESS HOURS (HOURS TO BE DETERMINED BY FXO PROJECT MANAGER) - LIGHT SWITCHES AT THE LIGHTING SWITCH BANK SHALL CONTROL THE LIGHT FIXTURES. EVENT: CONCLUSION OF BUSINESS DAY (TIME TO BE DETERMINED BY FXO PROJECT MANAGER) - TIMECLOCK SHALL SWEEP "OFF" ALL LIGHTS EVENT: AFTER BUSINESS HOURS - LIGHT FIXTURES SHALL REMAIN "OFF". - IF AFTER HOURS CONTROL OF THE LIGHT FIXTURES IS DESIRED, THE OVERRIDE SWITCH SHALL SERVE AS AN OVERRIDE SIGNAL TO THE TIMECLOCK AND THE LIGHT SWITCHES SHALL BE CAPABLE OF CONTROLLING THE LIGHT FIXTURES AGAIN (2 HOUR OVERRIDE MAX). 0 0 0 DAYLIGHT AREA (STOREFRONT) 'a' a DAYLIGHT AREA (STOREFRONT) 'b' ENTRY & SELF-SERVICE LIGHTING Oct 0 ENTRY & SELF-SERVICE LIGHTING 'd' 0 B 0 0 0 RETAIL LIGHTING 'e' RETAIL LIGHTING PACK AND SHIP & PRODUCTION LIGHTING rg. 0 PACK AND SHIP & PRODUCTION LIGHTING 'h' 0 O A 0 0 PRODUCTION & SIGN & GRAPHICS LIGHTING O 0 PRODUCTION & SIGN & GRAPHICS LIGHTING IJ, COMPUTER SERVICES LIGHTING 'k' 0 COMPUTER SERVICES LIGHTING 0 0 0 BREAK AND HANDUNG LIGHTING , m 0 BREAK AND HANDUNG LIGHTING 'n'n 0 0 0 LIGHTING (1 e OVERRIDE (AFTER HOURS) NOTE: SWITCHES SHALL BE LABELED AS SHOWN ABOVE 2 SALESLIGHTING SWITCH BANK SCALE: NONE LIGHTOLIER - ULTRA MAX BALLAST & ULTRA LAMPS - DUAL VOLTAGE QTY QT' TYPE MFG CATALOG # DESCRIPTION GE LAMP PART NUMBER LAMP DESCRIPTION LAMP QTY PER FIXTURE AREA IN BRANCH 72 A10 LIGHTOLIER CFS2GPF332UNVGI 2'x4' Recessed 3 -Lamp DIRECT/INDIRECT PERFORATED GE ULTRAMAX BALLAST (PROVIDE FIXTURE WITH 2 BALLASTS) GEF28T8SP41UMX (00257) T8 Ultra Watt -Miser 3 Express/Computer Services/Production / Offices 15 A20 LIGHTOLIER CFS2GPF332UNVG1-0X5 2x4 Recessed 3 -Lamp DIRECT/INDIRECT PERFORATED GE ULTAMAX BALLAST WITH EMERGENCY BALLAST 1100 - 1400 LUMENS (PROVIDE FIXTURE WITH 2 BALLASTS) GEF28T8SP41UMX (00257) T8 Ultra Watt -Miser 3 Express/Computer Services/Production / Offices/Breakroom 2 A5 LIGHTOLIER SLB2SFSVA332120GI-CUL 2'x4' Surface Fluorescent 3 -Lamp w/Prismatic Lens (PROVIDE FIXTURE WITH 2 BALLASTS) F32T8XLSP41ISWMECO (GE #48532) T8 Ultra Wall Miser 3 r Restrooms/Breakroom/Handling Area, as required 4 X1 DUAL -LITE LXURWE Universal Exit Sign, Red Letters, White Housing parking garage Indicate daylight zone in parking garage As required BREAK HANDLING I 122 EM/NL Al 0 A20 DM OFFICE X1 A10 HAL ROOM 123 Al 0 (A-9) A10 ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1'-0" PACK & SHIP 124 A10 A10 (A-7) A20 A10 A10 EM A10 / A10 / A10 A20 A-11) EM Al 0 SIGNS & GRAPHICS 113 Al 0 Al 0 Al 0 A20 EM/NL Al 0 A20 EM A10 A10 A10 Al 0 A10 Al 0 Al 0 Al 0 2009 Seat -tie Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Resldenuai LTG -INT Revised December 2010 Project Info Project Address FEDEX OFFICE - TUE"ILA, WA Date 5/9/2013 • 116 ANDOVER PARE EAST For Building Department Use SEATTLE,- WA 98188 - Applicant Name: Elan -ENGINEERS Applicant Address: 1538 ALEXANDRIA PIES, FT THOMAS, EY- 41075 Applicant Phone: 859-442-0050 Project Description ■ New Building D Addition Ed Alteration • Plans Included Refer to SEC Section 1513 for controls and commissioning requirements. t- -,O. CU111llllatice tion Prescriptive 0 Lighting PowerAllowance 0 Systems Analysis (See Qualltication Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box- sec. 1132.3) ■ No changes are being made to the -lighting and the space use hies not changed Q Less than ((5*).20%of the fixtures or of the lamps plus ballasts alone are altered, added, or replaced ((new)), installed wattage- not increased, & the space use has not changed. Maximum Allowed Lighting Wattage (Interior) Location (floor plan/room #) Occupancy Description Allowed Watts Dere" ',TOSS a ¢error Area in ft2 Allowed x Area salesfexoduction Retail 1.33 6076 8081 8ieak/Handling A10 &,7.20'- 2' x :4 ' Flourescents 10 90 900 Office Areas A10-- 2' x.4' Flouxescents 6 90' 540 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage (Interior) Total Allowed Watts 8081 Location (floor plan/room #) Fixture Description Number of Fixtures Watts! Fixture Watts Proposed Sales A10 & A20.- 2' x 4' Flouxescents 69- 90 6210 8ieak/Handling A10 &,7.20'- 2' x :4 ' Flourescents 10 90 900 Office Areas A10-- 2' x.4' Flouxescents 6 90' 540 Hal Room A10 - 2' x 4,' Flourescents 2 90 180 Resteomms A5 2' X 4' Flouxescents 2 90 180 Schedule with type and features, indicate locations 522.0 W.A. daylight zones - Indicate primary zone and secondary zone separately N.A. parking garage Indicate daylight zone in parking garage vertical glazing Indicate vertical glazing on plans Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 8010 Notes: 1 For proposed Fixture Description, indicate fixture type, lamp type le.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture; lamp, and ballast information. 2, For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as C'7 atrack ' specified j In Section 1.,.-'0. For line voltage track lighting, list the greater of actual luminaire wattage or length of multiplied by 50, or the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated Wattage. 3. List allTixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. Parking Garage Lighting - Maximum Allowed Wattage Location Occupancy Description Allowed Watts/ft` Gross Area (ft') Watts Allowed Parking Garage Lig g- Proposed Wattage Location Fixture Description # of Fixtures Watts/Fixture Watts Proposed Project Address FEDEX OFFICE - TUKWILA, QA Date 5/9/2013 The fdla'tng information is necessary to check apermit application fcr compliance with the lighting, motor, and transformer requirements in the 2009 Seattle Energy Code. Applicability (yes. no. n.a.) Code Section Component Information Require( Location on Plans Building Dept. Notes LIGHTING CONTROLS (Section 1513) Yes 1513:1 Local control/access. Schedule with type, indicate locations E2.0 The 2009 SEC Section 1510 specifies that parking garage lighting cannot he traded h other interior Total Proposed Watts Yes uhting or With exterior lighting. 2003 Seattle Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting, Motor, 2009 Seattle Energy Code Compliance and Transformer -Forms Er Nonresidential Permit Plans Checklist LTG -CHK Revised December 2010 and Multifamily Residential Project Address FEDEX OFFICE - TUKWILA, QA Date 5/9/2013 The fdla'tng information is necessary to check apermit application fcr compliance with the lighting, motor, and transformer requirements in the 2009 Seattle Energy Code. Applicability (yes. no. n.a.) Code Section Component Information Require( Location on Plans Building Dept. Notes LIGHTING CONTROLS (Section 1513) Yes 1513:1 Local control/access. Schedule with type, indicate locations E2.0 PRODUCTION/S&G LIGHTING Yes 1513.2 Area controls Maximum limit per switch 52.0 BREAK AND HANDLING LIGHTING Yes 1513.3 Daylight zone control Schedule with type and features, indicate locations 522.0 W.A. daylight zones - Indicate primary zone and secondary zone separately N.A. parking garage Indicate daylight zone in parking garage vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overheadglazing on plans - . N .A. 1513.4 Displayfexhib/special Indicate separate controls N.A. 1513.5 Exterior shut-off Schedule with type and features, indicate location N.A. (a) timer vv/backup Indicate location N.A. (b) photocell. Indicate location Yes 1513.3 Inter. -auto shut-off Indicate location Yes -1513.6.1 (a) occup. sensors Schedule with type and locations - - - - E2.'. 0 Yes 1513.6.2 (b) auto, -switches .--., Schedule with type and features (back-up, ov_ernde capabiltty); -' 'Indicatesize-of zone on plans 52.0 N -A. 1513.7 Hotel/motel controls Indicate location of ;morn master controls Yes 1513:8 Commissioning indicate requirements for lighting controls commissioning ' 52'•0 EXIT SIGNS (Section 1514) - Yes 1 1514 Max, watts Indicate watts for each exit -sign 152.0 LIGHTING POWER ALLOWANCE (Section,' 15304'532) N.A. 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, bAllests, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types. lamps, bahlasts, watts per fixture MOTORS (Section 1511) N.A. I 1511 IElec motor efficiency MECH-MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) N,A. 1540 Transformers Indicate size and efficiency If "no" is circled for any question, provide' explanation: TIMECLOCK SCHEDULE "TC" SPECIFICATIONS: 2 POLE, 20A RATING, 120V, 120V COIL CONTROL REMARKS: TIMECLOCK AUTO ON /AUTO OFF POLE CIRCUIT DESCRIPTION 1 A-21 LIGHTING CONTACTOR -'LC1' 2 A-23 LIGHTING CONTACTOR - 'LC2' (A-1 (A-5) Al 0 A Al 0 RETAIL I Al 0 A10 A10 EM EM A10 LIGHTING CONTACTOR SCHEDULE "LC1" SPECIFICATIONS: 8 POLE, 20A RATING, 120V, 120V COIL CONTROL REMARKS: TIMECLOCK AUTO ON / AUTO OFF COORDINATE SCHEDULE WITH OWNER POLE CIRCUIT DESCRIPTION 1 A-1 DAYLIGHT AREA LIGHTING 2 A-3 ENTRY/SELF SERVICE LIGHTING 3 A-5 RETAIL AREA LIGHTING 4 A-7 P&S/PRODUCTION LIGHTING 5 A-9 PRODUCTION/S&G LIGHTING 6 A-11 COMPUTER SERVICES LIGHTING 7 A-13 BREAK AND HANDLING LIGHTING 8 -- -- SPACE (A-3) Al 0 A10 Al 0 Al 0 A10 A10 A10 A10 A10 Al 0 A20 EM A10 A20 EM/NL A10 / Al 0 ENHANCED PACK & SHIP 126 Al 0 Al 0 X1 ENTRY 111 A10 / Al 0 SELF-SERVICE (A-17) AREA A20 11 EM A10 LIGHTING CONTACTOR SCHEDULE "LC2" SPECIFICATIONS: 4 POLE, 20A RATING, 120V, 120V COIL CONTROL REMARKS: TIMECLOCK AUTO ON / AUTO OFF COORDINATE SCHEDULE WITH OWNER POLE CIRCUIT DESCRIPTION 1 A-25 STOREFRONT RECEPTACLES 2 A-27 STOREFRONT RECEPTACLES 3 - -- SPACE 4 - -- SPACE f a REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUN 18 2013 City oi.Tukwila BUILDING DIVISION ARC DOT 18200 VON KARMAN .AVE I SUITE 910 IRVINE, CA 192612 t 949.705.0700 f 949.705.0701 MulvannyG2.com IIII , : .=. I MI I!illl IIII IIII141 VII illA'4I a . I VIII r ".1VV I EXPIRES FEB__D '? 2014 Isi 0 7411 L H KOHRS LONNEMANN HEIL ENGINEERS, PSC MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX ARCHITECTURAL PROJECT NO.: MEP PROJECT NO.: STRUCTURAL PROJECT NO.: CIVIL PROJECT NO.: 12-0253-01 A 12622.00 1 a3 U 0 CENTER NO.: SITE ID NO: 5173 989630 PROGRAM: RELO STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SEATTLE, WA 98188 CONTEMPORANEOUSLY WITH ITS ISSUE DATE 04.26.2013 AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS and ENGINERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND IS CONTRARY TO THE LAW. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF KINKO'S INC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH FEDEX KINKO'S. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. FEDEX KINKO'S IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: ISSUED FOR PERMIT 05.10.13 COMPUTER SERVICES A10 / A10 A20 A10 RECEIVED CITY OF TUKWILA PERMIT SET ISSUE DATE: 04.26.13 BID SET ISSUE DATE: -- CONSTRUCTION SET ISSUE DATE: 05.10.13 MENS RESTROOM EM r.�f..s�,s... JUN 1 1 2013 DRAWING TITLE: u_ ELECTRICAL LIGHTING PLAN f,d r/r/i/. f!!f/f.1 fr tor .I'.1 /.I%/%+',l dr dr ./+'.�/ii DRAWING NUMBER: s107 1 PANEL NAME A VOLTAGE 208 PHASE 3 WIRE 4 LOCATION BREAK/SERVER AREA SOURCE WIREWAY 125A M.C.B. 120 #L 1.5 R MHC H 1.00 BREAKER DESCRIPTION KVA/PHASE A B C DESCRIPTION BREAKER L R MHC# 480 1.00 39.9 AMP POLE AMP POLE 1 L 0 0.5 130.8 20 1 DAYLIGHT AREA LIGHTING 28•x•x,x,x,x,.:,x,,, .,,,,,,,,,,,,. ... DPWP, DPWS, BROTHER 5370 DW 20 1 BHP L8 HTG KW 2.6 FLA 2 3 09 0.5 DC WIRE MC TYPE MC FURN 20 1 ENTRY/SELF SERVICE LIGHTING , • • L I ffff. TDS CONTROLLER 20 1 208 02 • 2.6 4 5 11 0.5 GENERAL CONDUIT & WIRING EC EC 20 1 RETAIL AREA LIGHTING 7:- ... .% :,Yq /9 TDS SCANNER 20 1 1 1 8 AIR COND. UNIT 2.6 3 6 7 09 0.5 TELEPHONE CABLING 31 20 1 P&S/PRODUCTION LIGHTING 1 6 ' LAM 7020 20 1 TELEPHONE EQUIPMENT 0 7 HC 7.0 ACU -3 8 9 11 0.5 • P.O.S. DATA CONDUIT 20 1 PRODUCTION/S&G LIGHTING , • , x 2.1 :i:K:K::: - -1.4 (2) SONY PICTURE STATIONS 20 1 REFER TO SHEET DC -1 L 0 LOW 7.0 HC 10 11 1.3 0.7 120 • 20 1 COMPUTER SERVICES LIGHTING- - ... - ' .. • I 8 • SONY PICTURE STATION 20 1 MFR 0 5 TENANT'S 208 VOLT PANEL "B" 7.0 EC 12 13 09 0.5 0 • EXHAUST FAN 20 1 BREAK AND HANDLING LIGHTING /7 . ... :, .. IRC5045C, EPS -07 20 1 • L 8 MFR 3.7 MFR 14 15 aa 0.5 EC EC • 20- 1 OFFICE/RESTROOM LIGHTING - 2J k • BROTER MFC7220, EPS -06 20 1 L2 3.7 16 17 1 2 0.5 1.3 20 1 STOREFRONT SIGNAGE CIRCUIT __. •• /4 BROTER MFC7220, EPS -06 20 1 1 2 3.7 18 19 0.5 02 L 20 1 TIMECLOCK 'TC 0.7 . ::::::::::::::::::::::::::::::::::::::::::::2::::::::::::: . . EPREG, EPS -03, RCPT 20 1 0.1 05 20 21 0.6 02 T 20 I LIGHTING CONTACTOR 'LC1' : 0.7 ERE EPREG, EPS -03, RCPT 20 1 0.5 22 23 1.2 02 T 20 4 LIGHTING CONTACTOR 'LC2' _ . , : . % - 06 DESIGN CENTER EPS -01 20 1 04 24 25 04 20 1 STOREFRONT RECEPTACLES L I".w.: - . • ' COMPUTER WORKSTATIONS 20 1 07 26 27 04 20 1 STOREFRONT RECEPTACLES - . 11 F : • COMPUTER WORKSTATIONS 20 1 07 28 29 0.4 20 1 SPARE • - 0 7 COMPUTER WORKSTATIONS 20 1 07 30 31 1.6 0.5 20 4 MOTORIZED DOORS 1 2 ai - : COMPUTER WORKSTATIONS 20 1 07 32 33 1 8 ',.4 20 1 IRC5045F, EPS 07 x•x,x-x-x-x.x •---- 2.5 .:•-•-••,-•••••:••••J ............... COMPUTER WORKSTATIONS 20 1 , -H.-0.7 34 35 1 8 20 1 IRC5045C, EPS -02- - . , •• •• - . - - ........ 3M XEROX N5500 20 1 1 2 36 37 2.5 20 1 SPARE 1== •4 •,,,,, . _ PHASER 7760 20 1 1 4 38 39 20 1 SPARE0 . • 0 ' _ . SPARE 20 1 40 41 20 1 SPARE- - ...... - - a0 SPARE 20 I 42 TOTAL CONNECTED LOAD/PH SUBFED TCL FROM TOTAL CONNECTED LOAD 11.5 9.6 11.3 H = PROVIDE HID RATED BREAKER. S = PROVIDE SWITCHING DUTY RATED BREAKER. T = INDICATES TIME CLOCK CONTROLLED CIRCUIT G = PROVIDE A GFI BREAKER L = PROVIDE LOCK OFF HANDLE BREAKER 0.00 0.00 32.41 L = LITE DEMAND 125% 11.5 22.1 1.4 0.0 0.0 KVA KVA R = RCPT DEMAND 100% KVA NI = MSC DEMAND 125% KVA NOTES L PROVIDE (2)#12,(1)#12GND,3/4"C FOR ALL BRANCH CCTS UNLESS STATED OTHERWISE. 2. PROVIDE HACR RATED BREAKERS ON ALL MOTOR LOADS. 3. PROVIDE LOCKING TYPE BREAKER FOR ALL LIFE SAFETY AND NIGHT LIGHTING BRANCH CIRCUITS. H = HVAC DEMAND 100% IF H>C, 0% IF H<C KVA C = COOL DEMAND 100% IF C>H, 0%1F C<H KVA TOTAL PANEL DEMAND = 1 X * PHASES SHALL BE BALANCED TO WITHIN 10% * 35.0 KVA 1.00 1.00 35.0 KVA 97.2 AMPS AMPS PANEL NAME B VOLTAGE 208 PHASE 3 WIRE 4 LOCATION BREAK/SERVER AREA SOURCE WIREWAY 125A M.C.B. 120 #LR 1.5 R MC H 1.00 BREAKER DESCRIPTION KVA/PHASE A B C DESCRIPTION BREAKER LRMHC# R MHC# 480 1.00 39.9 AMP POLE AMP POLE 1 TOTAL 0.5 130.8 20 1 POS - PACK AND SHIP COUNTER 1.9 gia:•::::x•x:::•:::::::•x.::•:•: ... DPWP, DPWS, BROTHER 5370 DW 20 1 BHP 1.4 HTG KW 2.6 FLA 2 3 DC FURN 0.5 DC WIRE MC TYPE MC FURN 20 I POS - PACK AND SHIP COUNTER ... . 23x.x.x.x••••••,:: ... . (3)410, (1)#10 GND IN 3/4" CONDUIT 20 1 208 1.8 • 2.6 4 5 0.5 GENERAL CONDUIT & WIRING EC EC 20 1 POS - PACK AND SHIP COUNTER . ... ...„,.. .....• 1.5 BROTHER MFC7220 20 1 1 1.0 AIR COND. UNIT 2.6 3 6 7 • 0.5 TELEPHONE CABLING 31 20 I POS - FRONT COUNTERP1.9 8.0 , .. - ... D WP, DPWS 20 1 TELEPHONE EQUIPMENT 1.4 HC 7.0 ACU -3 8 9 3 0.5 • P.O.S. DATA CONDUIT 20 1 POS - FRONT COUNTER ............... ' 2.3 . •:•:•:•••••••• -:•:.: ..,,,,. IRC5051F 20 1 REFER TO SHEET DC -1 1.8 LOW 7.0 HC 10 11 EF -1 0.7 120 • 20 1 COKE COOLER - FRONT COUNTER 38 ..... 1.9 COMB SPREADER MAGNA PUNCH 20 1 MFR 1.2 TENANT'S 208 VOLT PANEL "B" 7.0 EC 12 13 EC 0.5 0 • EXHAUST FAN 20 1 POS - FRONT COUNTER 1.7. ... ... MAGNA PUNCH, COIL INSETER 20 1 • 1.2 MFR 3.7 MFR 14 15 • 0.5 EC EC • 20 1 POS - FRONT COUNTER . - . 21 ... .. .. ••••••• LAM DIS. 80 15 2 1.6 3.7 16 17 0.5 1.3 20 1 POS - FRONT COUNTER . •••• -- -- 1.6 3.7 18 19 0.5 1.3 20 1 WORK STATION - S&G 2.1 • x ..:: IR8105F 20 2 0.1 1.6 20 21 0.6 0.2 20 1 GERBER EDGE :•••••• • 2.2 EiRi:....i•:• -- -- -- -- 1.6 22 23 1.2 20 1 15" & 30" VINYL CUTTER . .. .. 2 8 20" H. CUTTER 15 2 1.6 24 25 0.4 20 1 HPz6100 0.5 ',:•••:•:•:-:-:-x-x-x..:x.x.x.:••••• -- -- 1.6 26 27 0.4 15 2 HPz61002 .x. .0 x -x -x -x,..-.,.. JOGGER PADDER 20 1 1.6 28 29 0.4 -- -- -- -- ., .„. - ••• - 2.6 CHALLENGE DRILL 30 2 2.2 30 31 1.6 204 1 BOOKLET MAKER FOLDER 3.8 :::::::::. • ........,... . (3)410, (10410 GND IN 3/4" COND. -- -- 2.2 32 33 0.8 20 1 AIR FEED FOLDER ''''' 0.8 • •• ..- SPARE 20 1 34 35 2.5 30 2 TITAN 1264WF . .••• •:, ...... • 2.5 SPARE 20 1 36 37 2.5 -- -- (3)410, (I)#10 GND. IN 3/4" COND.. . .. ... . SPARE 20 1 38 39 20 1 SPARE -:- 0.0 •:. SPARE 20 1 40 41 20 1 SPARE •• • 0.0 SPARE 20 1 42 SUBFED TCL FROM TOTAL CONNECTED LOAD 15.9 11.7 13.4 H=' PROVIDE HID RATED BREAKER. S = PROVIDE SWITCHING DUTY RATED BREAKER. T = INDICATES TIME CLOCK CONTROLLED CIRCUIT G = PROVIDE A GFI BREAKER. L= PROVIDE LOCK OFF HANDLE BREAKER 0.00 41.00 L = LITE DEMAND 125% 0.0 41.0 0.0 0.0 0.0 KVA R = RCPT DEMAND 100% KVA M = MISC DEMAND 125% KVA NOTES 1. PROVIDE (2)#12,(I)# I2GND,3/4"C FOR ALL BRANCH CCTS UNLESS STATED OTHERWISE. 2. PROVIDE HACR RATED BREAKERS ON ALL MOTOR LOADS. 3. PROVIDE LOCKING TYPE BREAKER FOR ALL LIFE SAFETY AND NIGHT LIGHTING BRANCH CIRCUITS. H = HVAC DEMAND 100% IF H>C. 0% IF H<C KVA C = COOL DEMAND 100% IF CAI, 0% IF C<H KVA TOTAL PANEL DEMAND = X * PHASES SHALL BE BALANCED TO WITHIN 10% * 41.0 KVA 1.00 41.0 KVA 113.9 AMPS PANEL NAME C VOLTAGE 208 PHASE 3 WIRE 4 LOCATION BREAK/SERVER AREA SOURCE WIREWAY 200A M.C.B. 120 #L 1.5 R MEC 120 1.00 BREAKER DESCRIPTION KVA/PHASE A B C DESCRIPTION BREAKER L R MHC# 480 1.00 39.9 AMP POLE AMP POLE 1 TOTAL 0.2 130.8 20 1 WIFI RECEPT 208 x 1.73 THEREFORE, THE 400 AMP SERVICE MARK ... ACU -1 (ON GRADE) 30 3 BHP • HTG KW 2.6 FLA 2 3 DC FURN 0.2 DC WIRE MC TYPE MC FURN 20 1 SECURITY RECEPT ... . 2.8 ... . (3)410, (1)#10 GND IN 3/4" CONDUIT -- -- 208 3 • 2.6 4 5 0.2 GENERAL CONDUIT & WIRING EC EC 20 1 TELPHONE BOARD • MFR 28 HC HC TELEPHONE CONDUIT W/ PULL WIRE 1 ACU -2 AIR COND. UNIT 2.6 3 6 7 • 1.0 TELEPHONE CABLING 31 20 1 SERVER CABINET 8.0 , . ' ....' . . ACU -2 (ON ROOF) 70 3 TELEPHONE EQUIPMENT HC HC 7.0 ACU -3 8 9 3 1.0 • P.O.S. DATA CONDUIT 20 1 SERVER CABINET • 8.0 '- ' (3)44, (1)#8 GND IN 1-1/4" CONDUIT -- -- REFER TO SHEET DC -1 P.O.S. DATA CABLING LOW 7.0 HC 10 11 EF -1 1.0 120 • 20 1 SERVER CABINET 38 • 8.0 -- -- -- -- MFR MFR TENANT'S 208 VOLT PANEL "B" 7.0 EC 12 13 EC 1.2 0 • EXHAUST FAN 20 1 MICROWAVE 4.9 :::•••••x •••••••••x.x-x-x•x•x•x:: • ACU -3 (ON GRADE) 45 3 • MFR MFR 3.7 MFR 14 15 • 0.7 EC EC • 20 1 REFRIGERATOR' . - . 4.4 ... .. .. ••••••• (3)#6, (1)# 10 GND IN 1" CONDUIT -- -- 3.7 16 17 1.3 20 2 WATER HEATER-- ... ... •• -- 3.7 18 19 1.3 -- -- -- -- 19 . :::: ... . ••• W/P GFI SERVICE RECEPTACLE 20 1 0.1 0.5 20 21 0.2 20 1 RECIRCULATION PUMP x.x.x.x•x•x•••x• 09 x• ,•• CONY RECEPTS 20 1 0.7 22 23 0.4 20 1 BREAK AREA DESK :-. •• ••:.:-: 1.3 CONV. RECEPTS 20 1 0.9 24 25 0.5 20 1 CASH COUNTDOWN OFFICE 0.5 ::::::::::::::::::x•x••••••••:•x•x.x.x.x.x:: SPARE 20 1 26 27 0.5 20 1 CSS OFFICE .,... 0.5 . ::•-•- :: SPARE 20 1 28 29 0.5 20 1 MD ASS'I. OFFICE' . .. .. ... 0.5 SPARE 20 1 30 31 0.5 20 1 MANAGERS OFFICE . 20 1 32 33 0.5 20 1 MD OFFICE0 ..... . 5 •• •• SPARE 20 1 34 35 0.9 20 1 DM OFFICE -- - -.....• • -.. --::L1- 0.9 SPARE 20 1 36 37 0.4 20 1 HAL ROOM . . . ... ... 20 1 38 39 20 1 SPARE -:- 0.0 ::::: ... SPARE 20 1 40 41 20 1 SPARE • 0.0 SPARE 20 1 42 TOTAL CONNECTED LOAD/PH SUBFED TCL FROM TOTAL CONNECTED LOAD 19.0 17.1 18.5 H = PROVIDE HID RATED BREAKER. S = PROVIDE SWITCHING DUTY RATED BREAKER. T = INDICATES TIME CLOCK CONTROLLED CIRCUIT G= PROVIDE A GFI BREAKER. L = PROVIDE LOCK OFF HANDLE BREAKER 0.00 54.50 L = LITE DEMAND 125% 0.1 11.8 3.4 39.9 0.0 KVA R = RCPT DEMAND 100% KVA M = MISC DEMAND 125% KVA NOTES 1. PROVIDE (2)#12,(1)#12GND,3/4"C FOR ALL BRANCH CCTS UNLESS STATED OTHERWISE. 2. PROVIDE HACR RATED BREAKERS ON ALL MOTOR LOADS. 3. PROVIDE LOCKING TYPE BREAKER FOR ALL LIFE SAFETY AND NIGHT LIGHTING BRANCH CIRCUITS. H = HVAC DEMAND 100% IF H>C, 0% IF H<C KVA C = COOL DEMAND 100% IF C>H, 0% IF C<H KVA TOTAL PANEL DEMAND = X * PHASES SHALL BE BALANCED TO WITHIN 10% * 55.2 KVA 1.00 55.2 KVA 153.4 AMPS NOTE: EQUIPMENT SHOWN FADED AND DASHED IS EXISTING TO REMAIN AND LANDLORD PROVIDED. 2ND FLOOR GRADE I I ELECTRIC ROOM 'LANDLORD'S SWITCHBOARD' 208/120V, 30,4W 1200A 400AF I I I I 11111,2$11111, v11111111, TO UTILITY TRANSFORMER ® ONE UNE DIAGRAM CODED NOTES: j I I I FEDEX OFFICE SPACE BASE BUILDING TELEPHONE DISTRIBUTION a S 30A 30AF PANEL A 208/120V 30,4W 125A MCB 42 POLE PANEL B 208/120V 30,4W 125A MCB 42 POLE PANEL C 208/120V 30,4W 200A MCB 42 POLE TENANT PHONE BOARD GRADE 1. PROVIDE NEW TRANSIENT VOLTAGE SURGE SUPPRESSOR. TVSS SHALL BE WIREMOLD "ZONEMASTER", MODEL #ZA120Y). COORDINATE WITH FEDEX OFFICE PROJECT MANAGER ON SITE. 2. PROVIDE NEW 240V, 400A/3P/400AF SWITCH LOCATED IN LANDLORD'S SWITCHBOARD. PROVIDE NAME PLATE AT SWITCH TO READ "FEDEX OFFICE". VERIFY EXACT LOCATION AND REQUIREMENTS IN FIELD. 3. PROVIDE NEW METER BASE AND ALL ASSOCIATED CURRENT TRANSFORMERS. E.C. SHALL CONTACT LOCAL UTILITY COMPANY TO ARRANGE FOR INSTALLATION OF NEW ELECTRIC METER AND TO ARRANGE ELECTRICAL SERVICE IN FEDEX OFFICE'S NAME. PROVIDE NAME PLATE AT METER TO READ "FEDEX OFFICE". VERIFY EXACT LOCATION AND REQUIREMENTS IN FIELD. 4. PROVIDE 208/120V, 30, 4W, 125A M.C.B. ELECTRIC PANEL 'A'. SEE SCHEDULE FOR REQUIREMENTS. 5. PROVIDE 208/120V, 30, 4W, 125A M.C.B. ELECTRIC PANEL 'B'. SEE SCHEDULE FOR REQUIREMENTS. 6. PROVIDE 208/120V, 30, 4W, 200A M.C.B. ELECTRIC PANEL 'C'. SEE SCHEDULE FOR REQUIREMENTS. 7. PROVIDE (4)#1/0, (1)#1/0 GND (GROUNDING IN ACCORDANCE WITH TABLE 250.122)IN 2-1/2" CONDUIT. IN ACCORDANCE WITH NEC 240.21B, FEEDER TAPS SHALL BE LESS THAN 10' IN LENGTH. 8. PROVIDE (4)#3/0, (1)#1/0 GND (GROUNDING IN ACCORDANCE WITH TABLE 250.122)IN 2-1/2" CONDUIT. IN ACCORDANCE WITH NEC 240.21B, FEEDER TAPS SHALL BE LESS THAN 10' IN LENGTH. 9. PROVIDE (4)#500 KCMIL, (1)#1/0 GND IN 4" CONDUIT. 10. PROVIDE 2" CONDUIT (WITFI PULL STRING) FROM TELEPHONE DISTRIBUTION TO NEW TELEPHONE BOARD IN TENANT SPACE. 11. PROVIDE (3)#8, (1)#8 GND (GROUNDING IN ACCORDANCE WITH TABLE 250.122) IN 1" CONDUIT. IN ACCORDANCE WITH NEC 240.21B, FEEDER TAPS SHALL BE LESS THAN 10' IN LENGTH. 12. PROVIDE NEW 30A/3P/30AF, NEMA -1, HEAVY DUTY DISCONNECT FOR NEW TVSS. COORDINATE EXACT LOCATION AND REQUIREMENTS IN FIELD. 13. PROVIDE NEW 8" X 8" X 72" WIREWAY AS REQUIRED. 14. PROVIDE BUTT SPLICE/FEEDER TAPS FOR CONNECTIONS TO INCOMING FEEDERS. FEEDER TAPS SHALL BE IN ACCORDANCE WITH NEC 240.21B. ONE -LINE DIAGRAM ONE LINE DIAGRAM GENERAL NOTES A. PARALLEL FEEDER CONDUCTORS SHALL BE CUT TO EXACTLY THE SAME LENGTHS AND SHALL BE FROM THE SAME FACTORY RUN. ALL CONNECTIONS FOR SAME SHALL BE TORQUED TO IDENTICAL VALUES. B. EXTERIOR ELECTRICAL WORK SHALL NOT ONLY BE WEATHERPROOF AND WATER -TIGHT, BUT SHALL ALSO BE RUST -RESISTANT. C. CONDUCTORS BELOW GRADE OR SUBJECT TO MOISTURE SHALL BE "XHHW-2". D. PROVIDE FACTORY SERIES COORDINATION FOR ALL CIRCUIT BREAKERS (INCLUDING ALL BRANCH BREAKERS), RELATIVE TO "UPSTREAM" BREAKERS, SO THAT ONLY THE BREAKER CLOSEST IN THE CIRCUIT TO THE LOAD TRIPS UPON AN OVERLOAD OR FAULT CONDITION. E. POWER DISTRIBUTION EQUIPMENT SUPPLIER SHALL PROVIDE EQUIPMENT APPROPRIATELY RATED AND BRACED TO ACCOMMODATE THE AVAILABLE FAULT CURRENT AT THE UTILITY COMPANY TRANSFORMER SECONDARIES. THIS SUPPLIER SHALL ACCORDINGLY PROVIDE ANY RELATED CALCULATIONS SO THAT THEIR EQUIPMENT IS PROPERLY COORDINATED FOR THE AVAILABLE FAULT CURRENT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THIS SUPPLIER WITH COPIES OF THE ELECTRICAL DOCUMENTS AS REQUIRED SO THAT PROPERLY RATED/BRACED EQUIPMENT IS PROVIDED UNDER BASE BID. F. GROUNDING ELECTRODE CONDUCTORS SHALL BE PROVIDED IN STRICT COMPLIANCE WITH N.E.C., INCLUDING N.E.C. ARTICLE 250 AND TABLE 250-66. THESE CONDUCTORS MAY NOT BE INDICATED ON RISERS OR SINGLE -LINES, BUT SHALL BE PROVIDED UNDER BASE BID NEVERTHELESS. G. EQUIPMENT GROUNDING CONDUCTORS SHALL BE PROVIDED IN STRICT COMPUANCE WITH N.E.C., INCLUDING N.E.C. ARTICLE 250 AND TABLE 250-122. THESE CONDUCTORS MAY NOT BE INDICATED ON RISERS OR SINGLE -LINES, BUT SHALL BE PROVIDED UNDER BASE BID NEVERTHELESS. H. WORKING CLEARANCES SHALL BE PROVIDED FOR ALL ELECTRICAL EQUIPMENT (SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, STARTERS, DISCONNECTS, ETC. AS APPLICABLE) IN STRICT COMPLIANCE WITH N.E.C. CHAPTER 1, PART B, SECTION 110-26(a). LOCATIONS SHOWN ON FLOOR PLANS ARE SCHEMATIC AND DIAGRAMMATIC IN NATURE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPLIANCE WITH THE ABOVE N.E.C. REFERENCE. THIS REQUIREMENT APPLIES TO EQUIPMENT ON FLOOR PLANS AS WELL AS TO EQUIPMENT SHOWN ON RISER. I. HOLD ALL NEW OVERHEAD ELECTRICAL WORK AS TIGHT AS POSSIBLE TO THE BOTTOM OF THE OVERHEAD STRUCTURE. LOCATE ANY RELATED PULLBOXES SO THAT THEY WILL BE FULLY ACCESSIBLE AFTER ALL CONSTRUCTION WORK IS COMPLETE. AS WITH ALL WORK, COORDINATE IN ADVANCE WITH ALL OTHER TRADES. J. ROUTE FEEDER CONDUITS BELOW GRADE WHEREVER POSSIBLE. VERY LIMITED SPACE EXISTS ABOVE ACOUSTICAL TILE CEILINGS AND MANY, IF NOT MOST, OF THE SPACE ABOVE THE GYPSUM BOARD CEILINGS IS NOT AVAILABLE FOR RUNNING CONDUIT. STUDY ALL ARCHITECTURAL, STRUCTURAL & MECHANICAL DRAWINGS VERY CAREFULLY BEFORE LAYING OUT FEEDER ROUTES. K. ALL PANELS HAVE NEMA 1 ENCLOSURES UNLESS NOTED OTHERWISE. L ALL PANELS ARE SURFACE MOUNTED UNLESS NOTED OTHERWISE. M. E.C. SHALL BE RESPONSIBLE FOR BALANCING ALL PHASES TO WITHIN 10%. SCALE NOT TO SCALE TENANT ELECTRIC LOAD SUMMARY DESCRIPTION N.E.C. CONNECTED kW VOLTAGE MULTIPLIER PER N.E.C. N.E.C. DEMAND kW LIGHTING 8.0 120 1.25 10.0 SIGNAGE 1.2 120 1.25 1.5 EQUIPMENT RECEPTACLES 74.6 120 1.00 74.6 WATER HEATER 2.5 208 1.25 3.1 HVAC EQUIPMENT 39.9 480 1.00 39.9 MISC. EQUIPMENT 1.3 120 1.25 1.6 TOTAL 127.5 130.8 NEC DEMAND kW x 1000 = MINIMUM FEEDER AMPERAGE 363.5 AMPS IS ADEQUATE SYSTEM VOLTAGE x 1.73 90.9 kW x 1000 = 208 x 1.73 THEREFORE, THE 400 AMP SERVICE CTRICAL RESPONSIBILITY EXISTING 1 FURNISHED BY INSTALLED BY REMARKS SCHEDULE LANDLORD FEDEX OFFICE TENANT CONTRACTOR OTHERS LANDLORD FEDEX OFFICE TENANT CONTRACTOR OTHERS MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRIC ROOM MG MAGNETIC STARTER OR CONTACT BAS BUILDING AUTOMATION SYSTEM CN CONTROLS • MS MANUAL STARTER LOW LOW VOLTAGE CONTROLS TS TOGGLE SWITCH • VFD VARIABLE FREQUENCY DRIVE LINE LINE VOLTAGE CONTROLS SERVICE ENTRANCE CONDUIT TO LEASE SPACE MFR MANUFACTURER MSR MANUAL STARTER W/CONTROL RELAY RLINE REVERSE ACTING LINE VOLTAGE STAT • PC PLUMBING CONTRACTOR OV OVERCURRENT PROTECTION MAN MANUAL • OR OWNER OR OTHERS SERVICE ENTRANCE FEEDERS TO LEASE SPACE MCA MINIMUM CIRCUIT AMPACITY • CP CORD AND PLUG CONNECTION • MARK DESCRIPTION METER REQUIREMENTS PHASE EMERG BHP • HTG KW WATTS FLA • OCP DC FURN LIGHT FIXTURES AND LAMPS DC WIRE MC TYPE MC FURN • MC WIRE CN TYPE CN FURN • CN WIRE SD QUAN OUTLETS AND SWITCHES AIR COND. UNIT 208 3 • • 22 GENERAL CONDUIT & WIRING EC EC EC • MFR MFR MFR • HC HC TELEPHONE CONDUIT W/ PULL WIRE 1 ACU -2 AIR COND. UNIT • 3 • TELEPHONE CABLING 31 45 EC EC • MG MFR MFR • LOW TELEPHONE EQUIPMENT HC HC 1 ACU -3 • 208 3 • P.O.S. DATA CONDUIT 58 • EC EC EC • MFR REFER TO SHEET DC -1 P.O.S. DATA CABLING LOW HC HC HC • EF -1 EXHAUST FAN 120 • TENANT'S 208 VOLT PANEL "A" 38 • MFR • MFR MFR TENANT'S 208 VOLT PANEL "B" EC EC MAN • EC EC 0 • EXHAUST FAN 120 TENANT'S 208 VOLT PANEL "C" • 38 0.5 • MFR MFR FIRE ALARM SYSTEM MFR EC EC • MAN EC EC • 0 HVAC ELECTRICAL COORDINATION SCHEDULE (HECS) ABBREVIATIONS CONTRACTOR TYPE MOTOR CONTROL TYPE CONTROL TYPE DC LOCAL DISCONNECT EC ELECTRICAL CONTRACTOR CS COMBINATION STARTER TC TIMECLOCK MC MOTOR CONTROL (POWER) EX EXISTING MCC MOTOR CONTROL CENTER CPT CONTROL POWER TRANSFORMER SD DUCT SMOKE DETECTOR FC FIRE PROTECTION CONTRACTOR MG MAGNETIC STARTER OR CONTACT BAS BUILDING AUTOMATION SYSTEM CN CONTROLS GC GENERAL CONTRACTOR MS MANUAL STARTER LOW LOW VOLTAGE CONTROLS TS TOGGLE SWITCH HC - HVAC CONTRACTOR VFD VARIABLE FREQUENCY DRIVE LINE LINE VOLTAGE CONTROLS C/B H.A.C.R. CIRCUIT BREAKER AT SOURCE PANELBOARD MFR MANUFACTURER MSR MANUAL STARTER W/CONTROL RELAY RLINE REVERSE ACTING LINE VOLTAGE STAT FUSE FUSE AT LOCAL DISCONNECT (VERIFY FIELD RATING) PC PLUMBING CONTRACTOR OV OVERCURRENT PROTECTION MAN MANUAL FLA OPERATING FULL LOAD AMPS OR OWNER OR OTHERS FA FIRE ALARM MCA MINIMUM CIRCUIT AMPACITY CO CARBON MONOXIDE SENSOR CP CORD AND PLUG CONNECTION INT INTEGRAL TO EQUIPMENT MARK DESCRIPTION VOLTS PHASE EMERG BHP HP HTG KW WATTS FLA MCA OCP DC FURN DC INST DC WIRE MC TYPE MC FURN MC INST MC WIRE CN TYPE CN FURN CN INST CN WIRE SD QUAN ACU -1 AIR COND. UNIT 208 3 22 30 EC EC EC MG MFR MFR MFR LOW HC HC HC 1 ACU -2 AIR COND. UNIT 208 3 31 45 EC EC EC MG MFR MFR MFR LOW HC HC HC 1 ACU -3 AIR COND. UNIT 208 3 58 70 EC EC EC MG MFR MFR MFR LOW HC HC HC 1 EF -1 EXHAUST FAN 120 1 38 0.5 MFR MFR MFR MFR EC EC EC MAN EC EC EC 0 EF -2 EXHAUST FAN 120 1 38 0.5 MFR MFR MFR MFR EC EC EC MAN EC EC EC 0 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUN 18 2013 --City of Toikwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 1 2013 PERMIT CENTER ARCHITECT 18200 VON KARMANI AVE I SUITE 910 IRVINE, CA I 92612 'III: .11,11 t 949 705 0700 f 949.705.0701 MulvannyG2.co 1111111 1,001 11111111.11111111111.1111u,li111111111111111ili011111,M1P.IINI1111131i1111111111!111111:,111111,1:1111111111111111!!,,T1)!:,...,,..,,,•.1,,!1111111ii,yiilllill1411111111111ii:1110,11,1111$11,111!illill1111191,10,,,A,H:11!!!IVIIIIIIIIIIII ,c1 74 r EXPIRES FEB 02 2014 tIM 792O1 gig L KOHRS LONNEMANN HEIL ENGINEERS, PSC MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX ARCHITECTURAL PROJECT NO.: MEP PROJECT NO.: STRUCTURAL PROJECT NO.: CIVIL PROJECT NO.: 12-0253-01A 12622.00 CENTER NO.: 5173 116 ANDOVER PARK EAST SEATTLE, WA 98188 SITE ID NO: PROGRAM: 989630 RELO STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SEATTLE, WA 98188 CONTEMPORANEOUSLY WITH ITS ISSUE DATE 04.26.2013 AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS and ENGINERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND IS CONTRARY TO THE LAW. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF KINKO'S INC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH FEDEX KINKO'S. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. FEDEX KINKO'S IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: PERMIT SET ISSUE DATE: BID SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: 05.10.13 04.26.13 DRAWING TITLE: ELECTRICAL DETAILS & SCHEDULES DRAWING NUMBER: E-3.0 1. GENERAL REQUIREMENTS The General Provisions of the Contract including any General and Supplemental Conditions and General Requirements apply to the work in this section. Before submitting a bid, examine all Mechanical, Architectural, and/or Structural documents, visit the site and get acquainted with all conditions that may in any way whatsoever affect the execution of this contract. Take measurements and be responsible for exact size and locations of all openings required for the installation of work. Figured dimensions are reasonably accurate and should govern in setting out work. Where detailed method of installation is not indicated or where variations exist between described work and approved practice, direction of the Owner's representative on job site shall be followed. The contract includes all items of material and labor required for the complete installation and full operation of the electrical work as shown on . the drawingsand hereinafter specified. All work, materials, and equipment shall have a one year warranty after acceptance of the work by the Owner. Any defective items shall be removed and replaced at the electrical sub -contractor's expense and to the satisfaction of the Engineer. Perform work under this contract in close harmony with other contractors so completed work shall present a neat ,and workmanlike installation. Exposed finished materials and equipment shall be carefully cleaned and wiped to remove grease, smudges, dust and other spots and left smooth and clean. During the progress of the work, the electrical sub- contractor shall carefully clean up after his men and shall leave the premises and all portions of the building in which he is working free of debris and in a clean and safe condition. Tighten electrical connectors and terminals, including screws and bolts, in accordance with equipment manufacturer's published torque tightening values for equipment connectors. Where manufacturer's torquing requirements are not indicated, tighten connectors and terminals to comply with tightening torques specified in applicable UL and NEC Standards. Whenever the words "contractor", "this contractor", etc. appear on drawings or in these specifications for the Electrical Work, it shall refer to the Electrical Sub -Contractor. Whenever the word provide" appears in these documents, it shall be interpreted to mean "Furnish & Install". Outlet mounting heights as indicated on the plans are approximate to be used for bidding purposes only. _ The exact mounting height of outlets shall be determined in the field with relation to architectural details and equipment being served. It shall be the responsibility of this contractor to coordinate outlet location with equipment. The Owner's representative shall be permitted to relocate any outlet prior to installation within a 15 foot limit at no additional charge in contract price. All fasteners, hangers and methods of hanging exposed work in finished areas shall be submitted to the Owner's representative for approval before installation. If during construction if becomes apparent that certain minor changes in layout will effect a neater job or better arrangement, such alterations shall be made as part of the contract. Engineer's approval shall be obtained before making such changes. Workmanship throughout shall conform to the standards of best practice. Marks, dents or finish scratches will not be permitted on any exposed materials, fixtures or fittings. Inside of panels & equipment boxes shall be left clean. The system shall ring entirely free from ground when tested out in the presence of the Owner's representative. This contractor shall be responsible for the proper instruction of each system to the satisfaction of the Owner's representative. Upon completion of the job, this contractor shall furnish the Owner with a complete set of operating instructions on all electrical systems installed. The Electrical Contractor shall consult the plans of all other trades in all instances before installing his work so that his piping will not interfere with those branches. In the event of a conflict, this contractor shall report to the Owner's' representative at once and do no further work to be installed until a satisfactory arrangement is decided upon. Any work done, or equipment placed in position by this contractor, creating a conflict in violation hereof, shall be readjusted to the satisfaction of the Owner's representative at the expense of the contractor. The decision of the Owner's representative shall be final in regard to changes due to conflicting conditions. Contractor shall complete his work or any part thereof at such time as may be designated by the Owner, so that lit can be used for temporary or permanent use and such use of the system shall not be construed as an acceptance of same by Owner. 2. SHOP DRAWINGS The contractor shall submit shop drawings on all items of material and equipment for approval by the Engineer (i.e. conduit and fittings, wires and cables, outlets and junction boxes, switches, receptacles, panelboards, etc). The contractor is not authorized to purchase any material until such approval is obtained. A minimum of six separate sets of drawings is required and will be distributed as follows: 1 copy for Engineer's file; 1 copy for Architect's file; 2 copies for the Owner's file; 2 copies for the contractor. Shop drawings shall be neatly bound in a flat ring binder having job name and contractor's name on cover.?A single submission is preferred having all items included. Loose sheet or incomplete submittals will not be accepted. All items of material to be supplied which do not require shop drawing submission such as conduit, wire, boxes, etc., shall be listed as separate material showing manufacturer's name and catalog number and type and shall be included with shop drawings submittal. 3. RECORD DRAWINGS AND OPERATING INSTRUCTIONS & SERVICE MANUAL Two sets of mechanical/electrical drawings shall be provided as record drawings which shall be separate, clean, sepia reproducibles reserved for the purpose of showing a complete picture of the work as actually installed. These drawings shall also serve as work progress report sheets and the electrical sub -contractor shall make any notations, neat and legible thereon daily as work proceeds. The drawings shall be available for inspection at all times and shall be kept at the job at a location designated by the Owner's representative. At the completion of the work, these record drawings shall be signed by the electrical sub -contractor, dated and returned to the Owner's representative. Final payment of contract will not be made until receipt and review of said drawings. Provide two neatly bound (with tabbed sections) copies of maintenance and instruction books, parts list pertaining to all equipment furnished. Submit to the Owner's representative for approval. Final payment will not be made until drawings for record; maintenance and instruction manuals are delivered to the Owner's representative. 4. PERMITS AND REGULATIONS The latest edition of the National Electric Code shall be the minimum requirement for all work. All electrical materials used in this work and all workmanship and tests performed therein, unless specifically specified shall conform to the latest rules and regulations and specifications of the National Board of Fire Underwriters, local and state codes and authorities having jurisdiction and utility company. Examine the drawings and specifications for compliance with prevailing codes, regulations and ordinances and base bid and work accordingly. Any minor discrepancy between these drawings/specifications and codes, laws, ordinances, rules and regulations shall be corrected by this contractor as required without any additional reimbursement. Major discrepancies shall immediately be brought to the attention of the engineer (in writing), prior to installation, along with the contractor's proposed cost for correction. This contractor shall obtain and pay for all permits or certificates of inspection and approval required for this branch of the work. Owner shall be furnished with certificates of final inspection and approval prior to final acceptance of this branch of the work. 5. DRAWINGS AND SPECIFICATIONS The specifications and accompanying drawings are intended to describe the scope of all electric/mechanical work. The drawings are an outline to indicate the approximate location and arrangement of raceways, wiring and equipment. The drawings shall be followed as closely as possible in executing of the work. Should there be a conflict between drawings and specifications, this contractor shall refer the matter to the Owner's representative for a decision as to method or material. Electrical Contractor shall refer to drawings of all other trades for details, dimensions and locations of other work and route his work so as not to conflict with any other branch. This contractor shall be responsible for checking quantities of -equipment mentioned in the specifications with those shown on the drawings. If discrepancies are noted, provide the greater of the quantities or the better of the qualities as applicable. 6. MATERIALS AND EQUIPMENT All materials and equipment shall be new. All materials, apparatus and equipment shall bear the Underwriter's Laboratories Inc., label where regularly supplied. Certain manufacturers of material and equipment are specified and plans are detailed according to this material. This contractor shall base his bid on furnishing and installing this make of material and equipment. Where more than one make of material or equipment is specified, the contractor shall state in his bid which make he proposes to furnish. 7. ELECTRICAL IDENTIFICATION Provide manufacturer's standard self-adhesive vinyl tape not less than 3 mils thick by 1-1/2" wide. Where applicable, install on all concealed raceways at connection to all junction boxes, pull boxes, equipment, wall/floor/, etc. Unless otherwise indicated or required by governing regulations, provide orange tape with black letters. Provide circuit identification bands for all cables and conductors. Provide manufacturer's standard color coding for cable/conductor jacket and/or insulation for all cables and conductors of all systems. Match identification with marking system used in existing systems (where applicable), shop drawings, contract documents, and similar previously established identification for project's electrical work. Provide on all conductors of all systems. Install engraved plastic -laminate sign on major units of electrical equipment, including central or master unit of each electrical system including communication/control/signal systems, unless unit is specified with its own self-explanatory identification or signal system. Except as otherwise indicated, provide single line of text, 1/2" high lettering, on 1-1/2" high sign (2" high where 2 lines are required), white lettering in black field. Unless determined otherwise in field, provide text matching terminology and numbering of the contract documents and shop drawings. Secure to substrate with fasteners, except use adhesive where fasteners should not or cannot penetrate substrate. As a minimum provide signs for each unit of the following categories of electrical work where such work exists on the project all starters and disconnects; All remote fixture or equipment switching devices (via engraved wallplates); All System devices, ports, taps, J.B.'s, P.B.s, etc.; Panelboards, electrical cabinets; Any other equipment designated by Owner or engineer in field. All equipment & system identification nomenclature shown on drawings or listed herein is shown for general design and installation reference only. The actual nameplate, etc. nomenclature for this project shall be verified by electrical contractor in field prior to fabrication and where applicable, shall be an extension of existing nomenclature used on, the site as determined in field by electrical contractor. In addition to the above, all labeling for all electrical wiring work (for all systems) shall be 3M DCI No. 054007-11954 "SWD" Write -on Tape Dispenser Kit with factory provided special fast drying marker included with kit. All markings shall be clear and legible. As determined in field, provide color -coding for junction boxes, pull boxes and associated plates to match existing building standards. The following insulation color code shall be used for system and voltage identification for feeder and branch circuit wiring. 480Y/277V System - Brown, Orange, Yellow & Gray (neut.) Equipment Grounding - Green Systems - To match existing - verify in field. 8. GROUNDING 208Y/120V System - Black, Red, Blue & Gray (neut.) Equipment Grounding - Green Systems - To match existing - verify in field. All metallic conduit, surface wireways, supports, cabinet and equipment shall be grounded in accordance with the latest issue of the National Electrical Code and shown on plans. The ground terminals of receptacles shall be connected to the equipment ground bus of the source branch circuit panelboard. All grounding conductors shall be protected from mechanical injury. All connections to equipment or conduit shall be make with an approved conductor and same shall be bolted or clamped to equipment and conduit.?ATI contact surfaces shall be thoroughly cleaned and bright before connections to insure a good metal contact. 9. CONDUIT AND FITTINGS All wiring for different power voltages shall be installed in raceway systems separate from each other (i.e. 24V separate from 120/208V). Only voice and data cables may share raceways. All wiring run in finished spaces shall be run in wiremold steel raceway. All conduit installed indoors shall be galvanized steel EMT (3/4" minimum); all fittings for same shall be set screw type steel, with insulated throats. All wiring of all systems shall be installed in conduit unless specifically indicated otherwise herein or on drawings. Conduit runs exceeding 100 feet in length or having in excess of three 90 degree turns shall be provided with pull boxes. Conduit fill shall not exceed 30 percent. All conduit systems (including J.B.'s, P.B.'s, etc.) shall be permanently identified. New branch circuit home -run conduits shall be no larger than 1-1/4" diameter. Conduit fill shall not exceed NEC requirements. Conduit shall be cleaned inside before any wires are pulled. Conduit ends shall be capped and plugged with standard accessories as soon as conduit has been permanently installed. Conduit installed without conductors shall be provided with sweep bends and baling wire for pulling. All joints shall be made tight with watertight couplings matching conduit and all corners shall be make with long radius. The ends of all conduits shall be cut square and reamed and all joints brought to a shoulder. Conduit shall be continuous between outlets to make a complete installation and to effect a continuous ground. Suitable supports and fastening shall be provided for conduit. Conduit shall be supported by approved straps, fasteners and hangers. Hangers shall be suspended from rods. Perforated straps will not be acceptable. Fasteners shall be lead expansion shields in block orconcrete, toggle bolts in hollow walls, machine screws on metal surfaces and wood screws on wood construction. All conduit shall be supported independently from allother building systems and shall be . supported directly from structural components. Provide sleeves for all firewall and smoke partition penetrations (sealed accordingly). All raceways shall be entirely free of plaster, mortar, water and other foreign matter. Raceways installed under this contract without conductors shall have baling wire left in raceways from outlet to outlet for future pulling of conductors. Raceways open ends shall be plugged or capped in an approved manner. 10. METHOD OF WIRING - POWER Branch sub feeder circuits shall be installed as shown on the floor plans. Where outlets are indicated by letters on plans, they shall be controlled by corresponding switches. No wire size smaller than No. 12 shall be used for any branch circuit unless otherwise noted on plans for control circuits. Larger sizes shall be used where required and/or indicated on the plans. Distances from panel to first outlet of a 15 or 20 ampere branch circuit shall require the following minimum wire size to the first outlet. Up to. 100 feet: 12 100 TO 200 FEET: 10 More than 200 feet: 8 All branch circuits more than 200 feet in length shall be minimum No. 10 to the last outlet. Control circuits shall be No. 14 except for runs exceeding 300 feet where they shall be No. 12. Outlets shall be located approximately as shown on the plans and shall be wired to provide control of outlets indicated. All wires of any one circuit shall be run in the same conduit. All wires shall be run continuous from outlet to outlet. Insulation value of joints to be 100% in excess of wire. Mechanical wire splicers shall be Scotchlock insulated type, T&B Stakon or approved equal. The conductors terminating at each wired outlet shall be left not less than 8" long at their outlet fittings to facilitate installment of devices of fixtures. Friction and rubber tape conform to Federal Specifications HH -T-11 and HH -T-111. Plastic electrical tape shall be Scotch #33+ or approved equal. 11. METHOD OF WIRING - COMMUNICATIONS All wiring/cables of voice/data systems and all other systems shall be installed in conduit, 3/4" minimum as indicated on plans and details. Outlets shall consist of a flush wall mounted 4" square X 2-1/8" deep box with a single gang plaster ring. Maximum conduit fill for new work shall be 40%, based on manufacture's published data of cable outside diameter. Provide, cable, terminations, jacks, labeling, hardware, etc. as required for complete working systems. Determine exact locations of communication technology equipment, equipment outlets, etc. in field. Use caution not to exceed the allowed bending radius for respective cables and not to compromise the integrity of the cables during installation by pulling tie -wraps too tightly, damaging cables, etc. Raceway/Cabling bending radii shall be minimum as directed by cable manufacturer. Use pulling compound or lubricant, where necessary; compound must not deteriorate conductor or insulation. Neatly dress all cable work. Work shall be installed in a manner which results in maintaining a minimum distance of 24 inches from feeder/branch circuit raceways and from any ballasted lighting fixture. Provide color coded jackets to identify runs of different systems. Neatly route cables parallel and perpendicular to building architectural lines. Group cables by system type wherever possible. Verify exact locations of telephone switch, data server(s), head -end equipment, equipment outlets, etc. in field. Review all termination and labeling requirements with Owner in advance. All cable shall be provided with permanent adhesive labeling identification by this contractor. Provide transparent adhesive coverings over each label, wrapped around the labels at least two times. The long axis of the labels shall installed be parallel to the long axis of the respective cable assemblies. Labels shall be approximately 1-1/2" long by 3/8" high. Conduit 12. OUTLET, JUNCTION AND SWITCHBOXES Gang type outlet boxes shall not be used. The outlet box locations indicated on drawings shall be considered approximate, and therefore, it shall be incumbent upon this contractor to study the general construction with relation to spaces and equipment surrounding each outlet. All outlet, switch and junction boxes shall be made of code galvanized steel complete with rings and screw cover plates and located where shown and noted on drawings. Where conduit is concealed, boxes shall not be less than 4" square x 1-1/2" deep. All boxes shall be equipped with proper covers to bring flush with finished wall surface. Where outlet boxes occur in block, cinder, or concrete block, facing tile or other material where such materials form the finished wall surface, the opening for the box shall be cut neatly and of the size that the cover plate will cover all parts of the opening. In general, junction boxes shall be furnished and required by the National Electric Code, of the proper sizes, and shall be constructed of #12 gauge steel with removable front fastened on with counter sunk head screws or other approved means. For special application, junction boxes shall be noted, detailed and/or sized on the drawings or in the field as required. 13. HEIGHT OF BOXES Prior to rough -in, verify all box/device mounting heights and locations in field with Owner's representative relative to equipment being served and relative to existing conditions where applicable. In general, where not located at counter areas, the height of boxes from finished floor to center of boxes shall be as follows, unless otherwise noted on plans: Switches Receptacles Telephone Outlets (desk phone) Telephone Outlets (Wall phone) Data Cable Outlets Devices at special heights 14. WIRE AND CABLE 4'0" 1'6" 1'6" 4'0" 1'6" As directed in field. Furnish and install all necessary cable of the size and type indicated on the drawings or specified hereinafter. All wire shall be copper. All wiring shall be new. No wire smaller than #12 AWG shall be installed unless specifically designated. Use of #14 color coded wire will be allowed for control circuits only. All wiring shall be in conduit unless specifically indicated otherwise herein. All conductors shall be copper. Provide stranded conductors for all sizes unless indicated otherwise. Provide THHN/THWN insulation for all conductors size 500 MCM (kcmil) and larger, and no. 8 AWG and smaller. For all other sizes provide THW or THHN/THWN insulation as appropriate for the locations where installed. Provide color coded 1 insulation/'acket for phase identification. All wires shall be rated at 600 volts. Keep conductor splices to minimum. Pull conductors simultaneously where more than one is being installed in same raceway. Use UL listed pulling compound or lubricant, where necessary. Install splice and tap connectors which possess equivalent or better mechanical strength and insulation rating than conductors being spliced. Use splice and tap connectors which are compatible with conductor material. Increase wire sizes per NEC to offset voltage drop as/if required. Cable types AC and NMC are NOT permitted. 15. WIRING DEVICES DEVICE COLORS: Unless indicated otherwise within contract documents or directed otherwise in field, all normal devices shall be WHITE in color. SPECIFICATION GRADE RECEPTACLES: Duplex receptacles shall be equal to Leviton (NEMA 5-20R). Ground fault circuit interrupter duplex receptacles shall be equal to Leviton NEMA 5-20R. Duplex isolated ground receptacles shall be equal to Leviton NEMA 5-20R IG. Special purpose receptacles shall be of the size, type and manufacturer as indicated on the plans or as determined in field. SWITCHES: Single pole switches shall be equal to Leviton #1221-2 series. WALL PLATES: Provide wall plates with engraved legends where indicated on drawings and/or where required per ELECTRICAL IDENTIFICATION Section. All device wallplates shall be standard size; "midway", "oversized" ("jumbo") or "extra deep" wallplates shall not be acceptable. Construct with metal screws for securing plates to devices; screw heads colored to match finish of plates. Wallplates in finished areas shall be commercial specification grade, satin finish stainless steel, with beveled edges, equal to Leviton Type 430 series. Wallplates in unfinished areas shall be galvanized steel. 16. SUPPORTS, INSERTS, CUTTING AND PATCHING This contractor shall do all cutting and patching required for the admission of his work. Any damage done by this contractor to the building during the progress of his work shall be made good at his own expense. All patching shall be done by a skilled craftsman in that respective trade. It shall be the responsibility of this contractor to supervise the installation of, and pay for all additional members, wood or metal and labor which may be required to support any type of permanent or temporary electrical apparatus employed in the execution of this contractor's work. SEAL ALL NEW FLOOR, CEILING, WALL, SLAB, ETC. PENETRATIONS TO MATCH OR EXCEED EXISTING/NEW ASSEMBLY FIRE RATINGS. PROVIDE SLEEVE SEALS FOR ALL SLEEVES; PROVIDE SLEEVES FOR ALL PENETRATIONS. VERIFY REQUIREMENTS IN FIELD. ALL PENETRATIONS OF FIRE - RATED OR SMOKE -RATED WALLS, FLOORS, CEILINGS, ETC. SHALL BE SEALED IMMEDIATELY AFTER RACEWAYS ARE INSTALLED. ALL NEW ELECTRICALLY RELATED WORK SHALL BE SUPPORTED DIRECTLY FROM BUILDING STRUCTURAL MEMBERS. NEW ELECTRICALLY RELATED WORK SHALL NOT BE SUPPORTED FROM DUCTWORK, DUCTWORK HANGERS, CEILING SUPPORTS, EXISTING CONDUIT SUPPORTS, ETC. ALL CONDUITS (AND CABLE ASSEMBLIES, WHERE APPLICABLE) SHALL BE ROUTED PARALLEL TO BUILDING STRUCTURAL MEMBERS. ANY AND ALL NONCOMPLYING WORK INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE REMOVED AND REINSTALLED TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE AND THE ENGINEER, AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 17. LIGHTING FIXTURES All surface mounted ballasted fixtures shall be mounted with air spaces between fixture and surface per latest edition of NFPA/NEC. All recessed fixtures shall be equipped with necessary plaster frames and surface trim. All recessed fluorescent fixtures shall be equipped and suitably constructed to operate with "P" rated ballasts. All junction boxes and serviceable components (ballasts, thermal protection devices, fuses, etc.) for recessed fixtures shall be readily accessible for service or replacement from below the ceiling, without removing any ceiling components (other than tiles). All lighting fixtures utilized for emergency egress lighting shall be connected ahead of switching. All ballasts of the same type shall be of the same manufacturer and catalog number. All lamps of the same type shall be of the same manufacturer and catalog number. Provide low energy solid state rapid start electronic fluorescent lamp ballasts (less than or equal to 20% THD) specifically designed for operating lamp types indicated. Fluorescent ballasts shall be Motorola or Advance equal. Incandescent lamps shall be Sylvania or Philips, long life type (3000 hours). All incandescent lamps shall be inside frosted unless specifically directed otherwise. Provide socket adapters/extenders if required for accommodating the specified lamp. Fluorescent lamp color temperature shall be 3500K Compact fluorescent twin tube/dual twin tube lamps shall be Osram or Philips, 82 CRI, minimum 10,000 hours rated. Long fluorescent twin tube lamps shall be Osram or Philips, 82 CRI, 3150 initial lumens, minimum 20,000 hours rated. F32T8 fluorescent lamps shall be rapid start, energy saving type, minimum 80 CRI, minimum 3200 initial lumens and minimum 20,000 hours rated. Lamps shall be Sylvania, Osram or Philips, equal to Sylvania #F032/RS. Provide fixtures and/or fixtureoutlet boxes with hangers to properly support fixture weight. All lighting fixtures installed in or on suspendedceiling systems shall be anchored directly to the building structural system above (anchored per NEC). Such anchoring shall be independent of the ceiling support system. All fixtures shall be installed plumb and level. Support surface mounted fixtures greater than 2 feet in length at a point in addition to the outlet box fixture stud. . 18. MECHANICAL EQUIPMENT Provide all conduit, and outlet boxes as required for all control wiring and thermostats. Furnish and install power wiring and make line connections to all heating, ventilating and air conditioning equipment. Electrical Contractor shall examine the approved drawings of all branches and shall wire and connect all motors, disconnects, control devices and other items requiring electricity for operation. This contractor shall make the necessary electrical connections between the specified equipment and the junction box near equipment with flexible metallic conduit and matched connectors. No flexible conduit shall beexposed in finished rooms. Each motor shall have disconnect switch or manual starter installed per mechanical/electrical schedule ahead of motor or motor magnetic starter. The Electrical Contractor shall providecontrol and interlock wiringas specifically indicated on the drawings. All other control wiring required for operation of the systems shall be provided by the Heating Contractor. 19. FIRE ALARM SYSTEM CRITERIA FIRE ALARM SYSTEMS SHALL BE A SEPARATE PERMIT. FIRE ALARM SYSTEM DEVICES (SMOKE" DETECTORS, PULL STATIONS, BELLS, STROBES, ETC.) SHALL BE OF THE SAME MANUFACTURER AS, AND COMPATIBLE WITH, THE EXISTING BUILDING FIRE ALARM SYSTEM. PROVIDE AUXILIARY CONTACTS IF REQUIRED FOR SPECIAL APPLICATIONS. ALL STROBE ALARMS SHALL BE ADA COMPLIANT, MINIMUM 75CD PER ADA. ALL NEW WIRING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND IN CONDUIT (3/4" MINIMUM). FIRE ALARM SYSTEM WIRING SHALL BE INSTALLED IN A RACEWAY SYSTEM SEPARATE FROM SECURITY SUB SYSTEM WIRING WHERE/IF APPLICABLE. THE INSTALLATION SHALL INCLUDE A COMPLETE SYSTEM TEST OF THE EQUIPMENT BY THE LOCAL REPRESENTATIVE OF THE SYSTEM INSTALLED. THIS TEST SHALL BE PERFORMED IN THE PRESENCE OF REPRESENTATIVES OF THE OWNER, ENGINEER, AND LOCAL FIRE DEPARTMENT. THE FIRE ALARM SYSTEM SUPPLIER SHALL PROVIDE TO THE ELECTRICAL CONTRACTOR A COMPLETE SET OF FLOOR PLAN DRAWINGS SHOWING CONDUIT SIZES AND NUMBER OF CONDUCTORS REQUIRED TO ALL COMPONENTS PLUS DETAILED WIRING CONNECTIONS REQUIRED AT EACH TYPE OF DEVICE. IT SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM SYSTEMS MANUFACTURER TO SUBMIT THESE DRAWINGS TO THE STATE FIRE MARSHALL'S OFFICE (OR OTHER AUTHORITY HAVING JURISDICTION) FOR APPROVAL. THIS ACTION SHALL BE, TAKEN DURING THE SHOP DRAWING PROCEDURE. THE SYSTEM MUST BE APPROVED BY THIS AUTHORITY AND A COPY SUBMITTED TO THE ENGINEER WITH THE SHOP DRAWING SUBMITTAL. ALL FIRE ALARM SYSItM WORKING DRAWINGS SHALL BE PROVIDED BY MANUFACTURER. PROVIDE ALL REQUIRED MODIFICATIONS (CARDS, POWER SUPPLIES, HARDWARE, FIRMWARE, SOFTWARE, ETC.) TO THE EXISTING FIRE ALARM SYSTEM AS REQUIRED TO RENDER THE ENTIRE EXTENSION FULLY OPERABLE. PROVIDE ALL REQUIRED 20A/120VAC POWER AS REQUIRED TO ENERGIZE ALL NEW FIRE ALARM RELATED COMPONENTS. THIS REQUIREMENT APPLIES WHETHER OR NOT SUCH POWER WORK IS SHOWN ON THE DRAWINGS. BRANCH CIRCUITS SERVING FIRE ALARM RELATED EQUIPMENT SHALL BE DEDICATED TO FIRE ALARM RELATED EQUIPMENT ONLY. SMOKE DETECTOR LOCATIONS SHALL NOT EXCEED THE RATED COVERAGE OF THE DETECTOR AND, IN GENERAL, SHALL BE NO MORE THAN 15 FEET FROM A WALL OR 30 FEET APART. SMOKE DEFECTORS SHALL NOT BE INSTALLED WITHIN 3 FEET FROM A SUPPLY AIR DIFFUSER. PROVIDE CONTACT BASES FOR ALL APPLICATIONS WHERE AUXILIARY CONTACTS ARE REQUIRED. THE AUDIOVISUAL AND VISUAL -ONLY ALARM INDICATING DEVICES SHALL BE RED ADA -COMPLIANT UNITS (WITH MINIMUM 75 CANDELA ADA -COMPLIANT STROBES) WALL MOUNTED AT 6'-8" (TO BOTTOM OF THE DEVICE) AS SHOWN ON PLANS. STROBE UNITS SHALL BE SYNCHRONIZED WHEREVER REQUIRED BY ANY AUTHORITY HAVING JURISDICTION, INCLUDING ADAAG. ADDITIONALLY, WHERE REQUIRED BY LOCAL AUTHORITY, THE STROBES MUST MEET ANSI S3.41 TEMPORAL CODE. THE WATERFLOW SWITCHES, TAMPER SWITCHES AND PRESSURE SWITCHES SHALL BE PROVIDED BY THE SPRINKLER CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL WIRE AND PROVIDE THE RELATED MONITOR MODULES AS REQUIRED. PROVIDE ISOLATION MODULES AS REQUIRED TO ISOLATE WIRE TO WIRE SHORTS ON A DATA LOOP TO LIMIT THE NUMBER OF OTHER MODULES OR DEFECTORS THAT ARE INCAPACITATED BY THE SHORT CIRCUIT FAULT AND/OR GROUNDS. ISOLATION MODULES SHALL BE PART OF THE SMOKE DETECTOR BASE. THE ISOLATION MODULES SHALL PERMIT THE ENTIRE SYSTEM TO OPERATE INDEPENDENTLY OF THE AREA DISCONNECTED BY THE ISOLATION MODULE DUE TO WIRING FAULTS. PROVIDE MONITOR MODULES AS REQUIRED TO INTERFACE "NON-INTEWGENT" DEVICES INTO THE SYhItM AS SHOWN ON THE DRAWINGS (I.E. SPRINKLER FLOW SWITCHES, TAMPER SWITCHES, ETC.). PROVIDE CONTROL MODULES FOR ALL AUXILIARY DEVICES INCLUDING ALL SUPERVISED CONTROL FUNCTIONS SUCH AS AIR HANDLER SHUTDOWNS. EXTERIOR/ROOF MOUNTED DUCT SMOKE DETECTORS SHALL BE IN A NEMA4X ENCLOSURE. 20. ELECTRICAL DISTRIBUTION EQUIPMENT SAFETY SWITCHES, STARTERS, CONTACTORS & TIME CLOCKS: All safety switches shall be safety type, quick make and quick break, externally operated, heavy duty (type HD) as manufactured by Square D. Provide NEMA 1 or NEMA 3R enclosures as required. Size for load unless indicated transformers. All starters shall be sized according to load being served. Manual and magnetic starters thermal overload larger on drawings. Starters shall be Allen Bradley. Starters, in general, shall be equal to that indicated below unless otherwise indicated on the plans: 1 Phase Manual Starter in Finished Areas Allen Bradley Bul. 600TKX109 flush mounted, 2 pole toggle switch type with neon pilot; (for starters surface mounted to equipment, provide same except Bul. 600 TAX109 NEMA 1. 3 Phase Combination Magnetic Starters With Disconnect Size 1 minimum, equal to Allen Bradley Bul. 512, NEMA I enclosure. All magnetic starters shall be equipped with external pilot lights (color as directed), external reset button, external non- fused disconnect switch and external HOA selector switches in cover and with auxiliary contacts and with fused control elements shall be rated between 115% and 125% full load current or as called for under NEC. Coordinate overload requirements with respective equipment manufacturer prior to installation. PANELBOARDS: Distribution panels shall be Square D I -Line. 208Y/120 volt low voltage panels shall be Square D NQOD with bolt -on type branch breakers. All busses shall be copper. All branch circuit breakers shall be full size and rated for switching duty (SWD). All multi- pole branch breakers shall have internal common trip with single handle (handle -ties shall not be acceptable). Provide 20 (+/-) non -padlock type breaker lock -on devices and install on branch breakers as directed in field (night lights, computers, security, etc.). Provide detailed typewritten schedules for all panelboards. Circuit breakers shall be furnished as scheduled on the drawings or as otherwise required based on field determinations. All branch circuit breaker numbering shall be vertical, verify in field. Phase loads shall be balanced to within 10% of each phase. Photocells Photocells shall be Paragon #CW201 series, 2000W rated nippled to flush weatherproof outlet box plate (or equal by Tork, Precision). Determine exact mounting locations and adjustment requirements in field relative to structural and site conditions. Aim northward wherever not conflicting with artificial light sources. 21. TELEPHONE AND P.O.S. SYSTEM Furnish and install a system of conduit raceways. Outlet boxes and pull wires as shown on the drawings unless otherwise noted on plans. Telephone switching apparatus, conductors, instruments, miscellaneous equipment and appurtenances are not part of this contract and will be provided and installed by FedEx Kinko's. Outlet boxes to be 4" square minimum with single device cover and telephone plate. All pull wires are to be labeled for purpose designated. No other circuits are to be run in same conduit feeding isolated ground receptacles. TESTS AND ADJUSTMENTS All connections at panels, lighting, contactors and switches are to be made, all splices complete, all fuses in place and all circuits continuous from point of service connection to its final destination, and all covers and plates installed prior to the time of final inspection by FedEx Kinko's project manager. Upon completion of the work, all parts of the electrical installation shall be tested and proved free of unwanted grounds and other defects. All overload devices, including equipment furnished upon other contracts, shall be set and adjusted to suit the load conditions. Test and make connections/ adjustments for phase balancing. This contractor is to balance the voltage leaving the stepdown transformer to provide a secondary voltage of 120 minimum to 125 volts maximum by adjusting the transformer taps once all the final connections have been made to the low voltage panelboard. Include final balance report with as -built drawings. CLEANING At the end of the project, this contractor shall clean all equipment, including light fixtures, to the satisfaction of FedEx Kinko's. All dust, dirt, debris, and foreign matter shall be removed from all equipment. REVIEWED FOR 'p7 COMPLIANCE H N0_NEC JUN 18 2013 City TLIkWila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 112013 PERMIT CENTER ARCHITECT 18200 VON RMAN AVE I SUITE 910 IRVINE, CA 192612 t 949,705.0700" f 949,705.0701 Mulvanny2.co: „gym„momoiioui 111111111elill MAY 2 92013 K L L H KOHRS LONNEMANN HEIL ENGINEERS, PSC MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 Fr. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX ARCHITECTURAL PROJECT NO.: MEP PROJECT NO.: STRUCTURAL PROJECT NO.: CIVIL PROJECT NO.: 12-0253-01 A 12622.00 116 ANDOVER PARK EAST SEATTLE. WA 98188 CENTER NO.: 5173 SITE ID NO: 989630 PROGRAM: RELO STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SEATTLE, WA 98188 CONTEMPORANEOUSLY WITH ITS ISSUE DATE 04.26.2013 AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS and ENGINERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND IS CONTRARY TO THE LAW. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF KINKO'S INC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH FEDEX KINKO'S. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. FEDEX KINKO'S IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: ELECTRICAL LEGEND SYMBOL DESCRIPTION UGHTING TING CONTROL/SWITCI-UNG a,b,c SWITCHING DESIGNATION NL nl UNSWITCHED NIGHT -LIGHT FIXTURE SINGLE POLE SWITCH ty OCCUPANCY SENSOR AUTO WALL SWITCH 0 48" AFF Pc PHOTOCELL RECEPTACLES/MISCELLAMOUS OUTLETS DUPLEX RECEPTACLE 40 DOUBLE DUPLEX RECEPTACLE ("QUAD") d O SPECIAL PURPOSE II OUTLET - SEE SHEET A3.0 FOR MORE INFO DETERMINE EXACT ,NEMA CONFIGURATION IN FIELD WHERE APPLICABLE FOR RECEPTACLES HUBBELL #PFBRG1j; (SINGLE GANG), #PFBRG2 (TWO GANG) OR #PFBRG3 (THREE GANG) NONMETALLIC FLOOR BOX • OUTLET FOR POWER WHIP CONNECTION TO SYSTEM FURNITURE I MISCELLANEOUS O THERMOSTAT (LOW 'VOLTAGE) - FURNISHED, INSTALLED AND WIRED BY H.C. OUTLET BOX AND CONDUIT STUB -UP BY E.C. TEMPERATURE CONTROL SENSOR (LOW VOLTAGE) - FURNISHED, INSTALLED & WIRED BY H.C. OUTLET BOX AND CONDUIT STUB -UP BY E.C. s • INDICATES A DIRECT CONNECTION TO EQUIPMENT Ell HEAVY DUTY DISCONNECT SWITCH (NON-FUSED) 13 HEAVY DUTY DISCONNECT SWITCH (FUSED) MS MANUAL STARTER WITH PILOT LIGHT O MOTOR Imo RECESSED OR SURFACE MOUNTED PANELBOARD AS INDICATED ON PLANS PLYWOOD EQUIPMENT BOARD BY E.C. ELECTRIC UTILITY COMPANY METER el ii HAND DRYER OR HAND/HAIR DRYER RACEWAY/WIRE/CABLE --x(1,3) HOME RUN WITH CIRCUIT NUMBER(S) CABLING/RACEWAY - CEILING OR WALL - SEE SPECS. FOR APPL. CONDUIT/RACEWAY REQ'TS. (FULLY CONCEALED IN FINISHED AREAS, CONCEALED TO OVERHEAD STRUCTURE IN UNFIN. AREAS) CABLING/RACEWAY - BELOW FLOOR/GRADE - SEE SPECS. FOR APPL. CONDUIT/RACEWAY REQ'TS. O J JUNCTION BOX - ABOVE ACCESSIBLE CEILING OR AT STRUCTURE IN AREAS WITH NO CEILING JUNCTION BOX - WALL (FLUSH IN FINISHED AREAS) J ABBREVIATIONS AND NOTES E.C. ELECTRICAL CONTRACTOR H.C. H.V.A.C. CONTRACTOR P C PLUMBING CONTRACTOR S.C. SPRINKLER CONTRACTOR G.C. GENERAL CONTRACTOR AFF ABOVE FINISHED FLOOR (OR GRADE/PAVEMENT WHERE APPLICABLE) TO CENTER OF OUTLET (UNLESS OTHERWISE NOTED) W/P PROVIDE WEATHERPROOF EQUIPMENT/FIXTURE/DEVICE CH COUNTER HEIGHT OR SPECIAL HEIGHT DEVICE COORDINATE WITH EQUIPMENT & ARCHITECTURAL ELEVATIONS GFI / GFCI GROUND FAULT CIRCUIT INTERRUPTER DEVICE (UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS, DO NOT FEED DOWNSTREAM OUTLETS FROM LOAD SIDE TERMINALS OF GFI RECEPTS.) IG INDICATES ISOLATED GND. DEVICE W/PARITY SIZED ISOLATED/INSULATED EQT. GND. CONDUCTOR (GREEN W/YELLOW TRACER). PROVIDE DEDICATED #10 AWG NEUTRAL COND. FOR EA. PHASE COND. EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER FURNISHED & INSTALLED BY P.C., WIRED BY E.C. FRE ALARM FIRE ALARM SYSTEM DUCT SMOKE DETECTOR C TS FIRE ALARM SYSTEM KEYED TEST SWITCH WITH L.E.D. INDICATOR LIGHT MOUNT NO HIGHER THAN 6'-0" A.F.F. TO THE CENTER OF THE DEVICE Pi FIRE ALARM SYSTEM MANUAL PULL STATION F ED DO FIRE ALARM SYSTEM HORN/STROBE UNIT (PROVIDE MINIMUM 75cd STROBE COMPLIANT WITH A.D.A.A.G. AND PROVIDE HIGHER RATINGS WHERE INDICATED ON DRAWINGS) F FO FIRE ALARM SYSTEM STROBE -ONLY UNIT LINE TYPES ELECTRICAL WORK SHOWN BOLD -DASHED INDICATES SELECTIVE DEMOLITION WORK INTENDED TO BE REMOVED AS SELECTIVE ' DEMOLITION BY E.C. ELECTRICAL WORK SHOWN BOLD -CONTINUOUS INDICATES NEW WORK BY E.C. ELECTRICAL WORK SHOWN FADED INDICATES EXISTING WORK TO REMAIN OR NEW WORK BY, OTHERS AS APPLICABLE REVIEWED FOR 'p7 COMPLIANCE H N0_NEC JUN 18 2013 City TLIkWila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 112013 PERMIT CENTER ARCHITECT 18200 VON RMAN AVE I SUITE 910 IRVINE, CA 192612 t 949,705.0700" f 949,705.0701 Mulvanny2.co: „gym„momoiioui 111111111elill MAY 2 92013 K L L H KOHRS LONNEMANN HEIL ENGINEERS, PSC MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 Fr. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX ARCHITECTURAL PROJECT NO.: MEP PROJECT NO.: STRUCTURAL PROJECT NO.: CIVIL PROJECT NO.: 12-0253-01 A 12622.00 116 ANDOVER PARK EAST SEATTLE. WA 98188 CENTER NO.: 5173 SITE ID NO: 989630 PROGRAM: RELO STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SEATTLE, WA 98188 CONTEMPORANEOUSLY WITH ITS ISSUE DATE 04.26.2013 AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS and ENGINERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND IS CONTRARY TO THE LAW. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF KINKO'S INC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH FEDEX KINKO'S. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. FEDEX KINKO'S IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. PERMIT SET © 2012 FedEx Office NO. REVISIONS: DATE: PERMIT SET ISSUE DATE: BID SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: 05.10.13 04.26.13 DRAWING TITLE: ELECTRICAL SPECIFICATIONS DRAWING NUMBER: E-4.0 ISSUED FOR PERMIT 05.10.13 PERMIT SET ISSUE DATE: BID SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: 05.10.13 04.26.13 DRAWING TITLE: ELECTRICAL SPECIFICATIONS DRAWING NUMBER: E-4.0