Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL13-0639 - THE CONTAINER STORE - TENANT IMPROVEMENT
CONTAINER STORE, THE 2437 SOUTHCENTER MALL ELi 3-0639 City oPrukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 2437 SOUTHCENTER MALL TUKW Project Name: CONTAINER STORE, THE Permit Number: EL13-0639 Issue Date: 09/17/2013 Permit Expires On: 03/16/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: SCOTT KANAGA Address: 2805 FAIRMOUNT ST, STE 300 , DALLAS TX, 75201 Contractor: Name: HOLMES ELECTRIC CO Address: PO BOX 338 , RENTON WA 98035 Contractor License No: HOLMEEC549BH Phone: 214 303-1500 Phone: (253)479-4000 Expiration Date: 10/31/2014 DESCRIPTION OF WORK: NEW TENANT REQUIRING INCREASED ELECTRICAL SERVICE FROM LANDLORD DISTRIBUTION TO THE NEW TENANT SPACE. NEW INTEGRATED 100 AMP SWITCHGEAR IS PROVIDED TO SERVE NEW TENANT LOADS. LIGHTING INTERIOR TO SERVE EMERGENCY LIGHTING. LIGHTING CONTROL VIA BAS SYSTEM. Value of Electrical: NRES: $290,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKU,ERS/AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $4,786.75 2008 Date: 04, /7'/---3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the • forma - - •f ork. I am authorized to sign and obtain this electrical permit. Signature: Print Name: /7h�L Date: *A? This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL13-0639 Printed: 09-17-2013 • PERMIT CONDITIONS Permit No. EL13-0639 **ELECTRICAL** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL13-0639 Printed: 09-17-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/lwww.TukwilaWA.gov Electrical Permit No. et 0 M Project No. _ _ �_____._ Date Application Accepted: - tkK Date Application Expires: ____ (For ofce use Only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 2437 Southcenter Blvd AA ALL Tenant Name:`, 1+E- COIVIAr11 `S" t 1 E PROPERTY OWNER Name: Scott Kanaga Name: WEA Southcenter City: Dallas State: TX Zip: 75201 Address: 2800 Southcenter Email: scott.kanaga@gff.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON - person receiving all project communication Name: Scott Kanaga Address: 2808 Fairmount St, Suite 300 City: Dallas State: TX Zip: 75201 Phone: 214-303-1500 Fax: Email: scott.kanaga@gff.com King Co Assessor's Tax No.: 262304-9023 Suite Nuniber:__,157.5 Floor: 18e2 New Tenant: X Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.:. Valuation of Project (contractor's bid price): S.0'0;000 2-90100D Scope of Work (please provide detailed information): Rai.% Vejtameltafcl 1Q1CY.EJ%sGb E16G is J.&_ 5 esne..r *FROM, A)S .Igoniesl 1. Tb 146 McNz TE1a,NT *)Ne-E•14taks IweeIVAIED l .&orren0 ie. (6. PRoviD "b 70 SErPVE AIEL) re-AUI PT' 40i41-1:5. 4/6071:160. /N Je7brc TD 5C42Y6 EXIEje eipiej 2-74 . LT& de, Niro I, V l a di) s sys# t�4 Will service be altered? ❑ Yes IA No Type of Usc• L_. Adding more than 50 amps? is Yes ❑ No Type of work: ❑ New ❑ Addition ❑ Service Change ® Low Voltage ❑ Generator ® Fire Alarm Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:Applteulutns\Fm ms-Applicutmns On Lino2011 ApplmnnonstElectt icul Pet nut Appiienuun 'teemed 0-9-1I dune Rcviscd: Angnst 2011 bit ❑ Remodel ❑ Telecommunication gi Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152,85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANCES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits......... .... ,$81.90 number of added circuits 51 1.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) . $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions 510.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. ' I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Date: 6/2/ 5' �Jv��� ---b/� Telephone: �� ' 7 7- 3 Day P / / S� Mailing Address: 2- oe, (l � �r ,�- TR/eit//�i�' � 9848 City stntc Zip H:lApplica ions\Formx-Applications On L910201 I Apphcmlons•rlccitical I'ci mit Application Reascd R -9-I 1,0010 Revisal: Angus) 2011 bh Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0639 Address: 2437 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/28/2013 Applicant: CONTAINER STORE, THE Issue Date: Receipt No.: R13-02613 Payment Amount: $3,829.40 Initials: WER Payment Date: 09/12/2013 01:24 PM User ID: 1655 Balance: $0.00 Payee: WHITING -TURNER CONTRACTING COMPANY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0734942 3,829.40 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 3,829.40 Total: $3,829.40 Prinrari• (1Q-19-9(111 a City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL13-0639 Address: 2437 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/28/2013 Applicant: CONTAINER STORE, ,THE Issue Date: Receipt No.: R13-02024 Initials: JEM User ID: 1165 Payment Amount: $957.35 Payment Date: 06/28/2013 10:52 AM Balance: $3,829.40 Payee: PETE FITZGIBON, BY PHONE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 040135 ACCOUNT ITEM LIST: Description 957.35 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 957.35 Total: $957.35 Printed: 06-28-2013 INSPECTION RECORD Retain a copywith permit. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line ,(206) 431-2451 M -043 - PERMIT NO. Project: ,.,I Pft Type of Inspection: Address: Z/ ? 1 ri Date Called: Special Instructions: I Date Wanted: i C Requester: /4.,/ ` Phone No: vii Approved per applicable codes. Corrections required prior to approval. COMMENTS: -14/frv Inspector: Date: _ Q n REINSPECTION FEE REQUIRED. Prior to next inspection, fee'must be.- paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION. RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206).431-3670 Permit Inspection Request Line (206) 431-2451 640637 Project: co a Ak-tdce. sizd iv i Type of Inspection: /1/4 %41 address -Date ZY37 r� Called: Or Special -Instructions: Date Wanted:�q V o f Requester: i, Phone No: . .54 ©Z7( ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 11110. • uate: REINSPECTION FEE REQUIRED. Prior t� next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: ld INSPECTION RECORD 643,6(>341Retain a copy with permit INSPECTION NO. . PERMIT NO. CITY OF •TUKWI.LA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: r Type of Inspection: Address: Z Date Called: Special Instructio s: Date Wanted; . 'pt a.m.. . (5 Requester: Phone No: • QApproved per applicable codes. tI Corrections required prior to approval. COMMENTS: n./ n� (J /57- ��gqr 6-6l�o (Inspector: P Date:: 01 3 r t- REINSPECTIONFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 643-0437 Project: Codrkirfra i _ i Type of Inspection: g m t Al Address: 2431 4 3 A • I , 1 [�V V Date Called: Special Instruction. Date Wanted: Requester: r Ai V Phone No: zaI e5.1 ii7.1 JApproved per applicable codes. Corrections.required prior to approval. COMMENTS: ienu 11'A NAM 0-9 u0 46a1G tescm.aau\ Inspector: 941.4\ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ` 3° fry INSP CTION NO. INSPECTION RECORD Retain a copy with permit 613- 047 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Airt\'.1) Type of Inspection:�""""t ,,J. Addres : pi 3.7 I 11414, Date Called: Special Instructions' 1.; 41° - - C : Date Wanted: ,�(® / m Requester: it Pith''' Phone No: :5-61271 ElApproved per applicable codes: j J Corrections required prior to approval. COMMENTS: re)( tlif-AVN i Date: i' _0(Io f� n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: f INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:rmoi rs.h. Spike Type of Inspection:/j, f 141 /0 tA4 Addres .2Y 7v Date Called: - Special Instructionf: Date Wanted: ` J t p m. Requester: i Phone No: 156Wit Approved per applicable codes. Corrections required prior to approval. COMMENTS: �Q. u- 4-i(Dr.1 DS SorP-t TS; 4dP r t h -v45 6/-0,616 Date. or REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule.reinspection. INSPECTION -RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 a4.ot 37 Permit Inspection Request Line (206) 431-2451 Project: /1' � Soktr-tT �,C Type of Inspection: g . Aft i se Address: *7(.67Date ot, Called: Special Instruction : - • Date Wanted: l'n6 / V Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. vd COMMENTS: C61/14 CSAitg\ AS Plat 41.(yi�� �- z.o aievirit Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee mus be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit (3-0431 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: OodrAu /„/ Type of Inspection: -6040 iiJAddress. 2Date 7 findv ;1 Called: Special Instructions: x Date Wanted: ail . Requester: 1)14, Phone No: 35t gzi 1 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: r(ARIX>5 -coFF-(rs 4-s dit.truc,r, ,S�ffEl- E2.O Inspecoir: ✓Jf�tINAki< Date: r214 ?ft, REINSPECTION t1EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 6f3 —06 3 INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:6rA � OQtl/'" ` Ie -Oke Type of Inspection: /) 0 dot% Address: Date Called: Special Inst ucti ns: Date Wanted: ! 1t 171) . Requester: = V L Phone No: 201 ?a gRf ElApproved per applicable codes. • Corrections required prior to approval. COMMENTS: Yik iwp 91>5 /4 ktoJSP Date: 12( 3 /i3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 3401 PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 L Project: CC Type of Inspection: / Address:ZY3��v Date Called: Special lnstructio s: Date Wanted: / D m P.m. Requester: fill/' Phone No: rt 3C4 )'Z1 f QApproved per applicable. codes. Corrections required prior to approval:. COMMENTS: P� I h, PakieG-t-i\ GiAtth •R,410P\ 600-S 444D GoAhDXI `i� REINSPECTION FEE REQUIED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call -to schedule reinspection. 2_ INSPECTION NO. INSPECTION RECORD Retain a copy with permit 603 0631 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ezakti/��( 51f Type of Inspection:O`� 4 Address: 2937 t1�/ Date Called: � Special Instruction : t Date Wanted: 11 j(� L::�' p.m. Requester: Nth......, Phone No: 3510 Approved per applicable codes. Corrections required prior to approval. COMMENTS: foJ6P\ (a�u ��cxc� Roo tb,ry %sor(, Fi..00/s6A5r, REs�'rimDorickr5� A41) cb�tQol� ETnki JEsT�6tl� Inspector( ittifyyjatils\ Date: 111113 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit t.,3-0637 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: /% TA14 ", �K Type of Inspection: 7ix Address:Date Called: Special InstruU ctio s`. Date Wanted: t a( G p.m. Requester:112/14 V Phone No: joro gs/ g27+ EApproved per applicable codes. Corrections required prior to approval. COMMENTS: VAVIcrro Inspector: Nirti,64.16< Date: 1\1°( 1 0t (� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-0639 ( DATE: 06/28/13 PROJECT NAME: SITE ADDRESS: THE CONTAINER STORE 2437 SOUTHCENTEF: MALL X Original Plan Submittal Respc)nse to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division ® Fire Prevention Public Works El Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 07/02/13 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required D REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/30/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople P,er Friendly Page • Electrical Contractor A business licensed by LBJ to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name HOLMES ELECTRIC CO UBI No. 177003752 Phone 2534794000 Status Active Address Po Box 338 License No. HOLMEEC549BH Suite/Apt. License Type Electrical Contractor City Kent Effective Date 1/8/1946 State WA Expiration Date 10/31/2014 Zip 98035 Suspend Date County King Specialty 1 . General Business Type Corporation Specialty 2 Unused Parent Company Master Electrician INFORMATION License HILLME'973KR Name HILLMAN, ED Status Active Business Owner Information Name Role Effective Date Expiration Date HOLMES, JERAY A Agent 01/01/1980 Bond Amount HOLMES, MICHAEL J President 01/01/1980 929558590 RICHARDS, MICHAEL W Secretary 01/01/1980 ELECTRICAL CITATION RICHARDS, EUGENE M 11 /08/2012 01/01/1980 10/15/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 Western Surety Co 929558590 12/08/2012 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 11 /08/2012 3 HARTFORD FIRE INS CO 52BSBFB9243 12/08/2008 Until Cancelled 12/08/2012 $4,000.0012/09/2008 2 AMCASUALTY 9239830 12/08/1984 Until Cancelled 02/09/2009 $4,000.00 09/14/2008 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ESHA000715 7/25/2012 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EREEB00495 10/8/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 09/17/2013 0.1 1 1 PARKING DECK r dOIS LJ ❑ THEATRE ABOVE 0 RTU— 1 WR/ WP EXTERIOR WALKWAY mm STAIRS WR/ WP L1 LANDLORD TRASH WR WP RTU -3 EF -1 UPS 16 ROOF BELOW HIGH ROOF ROOF BELOW ELECTRICAL ROOF PLAN SCALE: 1 /8"=1'-0" SEPARATE PERMIT REQUIRED FOR: ai MethanicaI El Electrical erglumbing Comas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new pian submittal end may include additional plan review fees. j GENERAL ELECTRICAL NOTES: 1. LOW VOLTAGE CABLES TO RTU SHALL RISE UP WITHIN CURB. COORDINATE WITH BAS DRAWINGS. 2. PROVIDE SEPARATE PENETRATIONS FOR DISCONNECTS AND CONVENIENCE POWER. 3. ALL CONDUITS TO ROOF MOUNTED EQUIPMENT SHALL BE PROVIDED WITH ROOF JACKS AND SEALED WATER TIGHT. 4. ALL ROOF PENETRATIONS, PATCHING, AND REPAIR WORK TO BE PERFORMED BY ROOFING CONTRACTOR. ELECTRICAL PLAN NOTES: ❑1 2 3 4 F51 6 7 FURNISH AND INSTALL DISCONNECT. PROVIDE SINGLE POWER CONNECTION TO ROOF TOP UNIT/ CONDENSING UNITS, REFER TO ONE—LINE DIAGRAM (SHEET E-6.0) FOR DISCONNECT SIZES. 3/4" CONDUIT TO BUILDING AUTOMATION SYSTEM (BAS) IN TCS SPACE FOR OUTDOOR LIGHTING AND TEMPERATURE SENSOR. COORDINATE LOCATION AND EXACT REQUIREMENTS WITH BAS DRAWINGS. CIRCUIT WEATHER—PROOF/GFCI RECEPTACLE PROVIDED WITH ROOFTOP UNIT AS SHOWN. PROVIDE NEW 3/4" DIA. CONTROL CONDUIT, ROUTED ABOVE ROOF TO NEAREST CHASE, CONNECT DIVCON CONTROLLER IN TCS SPACE TO RTU'S FOR CONTROL WIRING AND FOR REMOTE TEST STATION SIGNAL WIRING. COORDINATE WITH BAS DRAWINGS. CONNECT EXHAUST FAN TO RESTROOM LIGHTING. EXHAUST FAN SHALL TURN 'ON' WHEN THE LIGHT FIXTURES ARE TURNED 'ON'. COORDINATE WITH TCS PROJECT MANAGER PRIOR TO ROUGH—IN. REFER TO DETAIL 4, SHEET E-6.2. EXHAUST FAN SHALL BE CONNECTED TO UPS CIRCUIT AND SHALL REMAIN ENERGIZED IN CASE OF POWER LOSS. UNIT SHALL BE OFF UNLESS UPS TURNS ON, THUS STARTING THE FAN. COORDINATE FINAL LOCATION WITH TCS PROJECT MANAGER PRIOR TO ROUGH—IN. DISCONNECT TO BE PROVIDED BY EQUIPMENT MANUFACTURER. FILE COPY Penult No. EL4seb0(39 Plan review approval is subject to errors and on inns. tir.7x va! of construction documents does not authorize thz.: ahaton of any adopted code or order. Receipt of approved Field Copy : _makes is 1mowledged: City Of i Ya BUILDING DIVISION REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC JUL '222013 35 City of Tukwila BUILDING DIVISION REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. RECEIVED CITY OF TUKWILA JUN 2 8 2013 PERMIT CENTER t H g ■ 00 .�-� ,11 § = .U 2 O O p M ro • soc •cf cf 1 N N i INN law ea O ElmeN LOL▪ im 0 O to O c, O 00 C3 Ngo © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM m 0 (r) m z—� J o03 LLJmsi; O W Cr Q LL F-- LLQ z w< U J Z I— Z 0 0 12 V) CO No. Date Item REVISIONS TG Drawn TG Checked TG Approved ELECTRICAL ROOF PLAN Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E-1 .R H 0 ..irD,\ U- in LC E T r -i U -1 12 M co vii 2 N N CD 043 i C E i ® ":: o 0 aN V CJ Cn © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM m LZLJQ�� LLJ Z W W -I Z , i ZOQ LU C I- F -- - n 0 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS JA Drawn TG Checked TG Approved ELECTRICAL LEGEND, DETAILS, AND SCHEDULES Project No. 13007.00 Date PERMIT - 06.24.13 Last Revision E-1 . o LIGHT FIXTURE SCHEDULE SPECIAL NOTES TYPE MANUFACTURER/MODEL # LAMPS INPUT INPUTDESCRIPTION ABBREVIATIONS GENERAL NOTES NO. TYPE VOLT WATTS VAA. GENERAL CONTRACTOR SHALL COORDINATE ON SITE MEETING WITH ABBREVIATIONS NECESSARILY ON THE DRAWINGS.) ELECTRICAL SYMBOLS LEGEND 63 64 4' SUSPENDED DIRECT/INDIRECT FLUORESCENT BAFFLE LIGHT CONTAINER STORE REP PRIOR TO WORK ON HVAC, ELECTRICAL AND Al PEERLESS ICDM8-2-32-SBP-4FT-R4-277-GEB10-SCT- 2 F032/841/XP/XL/ECO3 277 FIXTURE WITH 100% DOWNLIGHT FOR (2) LAMPS. SURFACE NECESSARY SPRINKLER SYSTEM INCLUDING SHOP DRAWINGS. A M WIRING DEVICES & OUTLETS 1. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 1SE-EC-LP841-F2/24-ACG-0041 FIXTURE TO CIRCUIT THROUGH INVERTER MOUNT TO UNISTRIT GRID. PROVIDE WITH ALL MOUNTING HARDWARE AND HANGERS, AND WITH ALL FITTINGS, ELBOWS, ETC. FOR A CONTINUOUS ROW OF FIXTURES, AND TANDEM MOUNTING KITS AS REQUIRED. ELECTRONIC BALLAST. UL LISTED. LIGHT FIXTURE FURNISHED BY OWNER, INSTALLED BY EC. B. CONTRACTOR SHALL PREPARE COORDINATION DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL AND FIRE SPRINKLER WORK PRIOR TO MEETING C. TENANT (THE CONTAINER STORE) TO FURNISH ALL LIGHT FIXTURES & LAMPS EXCEPT "N" &"Ni ". CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AND SUPPORTS. A AMPERES AF AMPERE FUSE AFC' ARC FAULT CIRCUIT INTERRUPTER AFEA AREA FOR EVACUATION ASSISTANCE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE MATY MASTER ANTENNA TELEVISION SYSTEM MAX MAXIMUM MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL SINGLE POLE WALL SWITCHNO LETTER DESIGNATION) ( SWITCH LETTER DESIGNATIONS AS FOLLOWS: 2 = TWO POLE WALL SWITCH OS = OCCUPANCY SENSOR 3 = THREE-WAY WALL SWITCH P = SPST PILOT LIGHT SWITCH (LIT WHEN ON) 4 = FOUR-WAY WALL SWITCH K = KEYED LIGHT SWITCH 2. THE ELECTRICAL CONTRACTOR SHALL NOTIFY AND OBTAIN APPROVAL FROM THE ENGINEER/ARCHITECT OF RECORD FOR ANY CHANGES DUE TO FIELD CONDITIONS OR OTHERWISE PRIOR TO EXECUTION. 3. IN THE EVENT OF A CONFLICT OR INCONSISTENCY BETWEEN ITEMS INDICATED ON THE PLANS, SPECIFICATIONS, OR CODE REQUIREMENTS, THE NOTE OR CODE WHICH ESTABLISHES THE HIGHER STANDARD SHALL PREVAIL. 4. RECORD DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT BEFORE FINAL RECORD PAYMENT WILL BE ISSUED. A2 PEERLESS 4 F032/841/XP/XL/ECO3 277 121 125 8' SUSPENDED DIRECT/INDIRECT FLUORESCENT BAFFLE LIGHT FIXTURE WITH 100% DISTRIBUTION FOR (4) LAMPS. SURFACE MOUNT AI ANALOG INPUT AIC AMPERE INTERRUPTING CURRENT MFR MANUFACTURER MG MOTOR GENERATOR D = DIMMER TYPE SWITCH M = MOTOR RATED SWITCH 5. THE ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD OF ONE (1) YEAR AFTER FINAL ACCEPTANCE BY THE ARCHITECT. ICDM8-2-32-SBP-BFT-R4-277-GEB10-DCT- EC-DTC-LP841-F2/24-0041 TO UNISTRIT GRID. PROVIDE WITH ALL NECESSARY LIGHTING CONTROL/BMS AL ALUMINUM MIN MINIMUM 6 SIMPLEX RECEPTACLE - NEMA 5-20R, UNO 6. EQUIPMENT LOCATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS TAKE PRECEDENT OVER THOSE SHOWN ON THE ELECTRICAL (2) OF (2) LAMPS PER (1) 4' SECTION ON EMERGENCY INVERTER CIRCUIT PROVIDE WITH (1) END -CAP. MOUNTING HARDWARE AND HANGERS, AND WITH ALL FITTINGS, ELBOWS, ETC. FOR A CONTINUOUS ROW OF FIXTURES, AND TANDEM MOUNTING KITS AS REQUIRED. ELECTRONIC BALLAST. UL LISTED. LIGHT FIXTURE FURNISHED BY OWNER, INSTALLED BY EC. 1. LIGHTING CONTROL SYSTEM SHALL BE A PROPRIETARY SYSTEM BY DIVCON EMS. CONTRACTOR SHALL CONTACT DIVCON FOR QUOTE & SCOPE OF WORK. 2. CONTRACTOR SHALL INCLUDE COST FOR A COMPLETE AND OPERATIONAL SYSTEM. INCLUDING EQUIPMENT, LOW VOLTAGE AND LINE VOLTAGE AO ANALOG OUTPUT AP ACCESS PANEL ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE B MLO MAIN LUGS ONLY MOCP MAXIMUM OVERCURRENT PROTECTION MSB MAIN SWITCHBOARD N N/A NOT APPLICABLE 8 DUPLEX RECEPTACLE - NEMA 5-20R, UNO GFCI TYPE RECEPTACLE 4iii DOUBLE -DUPLEX RECEPTACLE - NEMA 5-20R, UNO }� DRAWINGS. 7. THE ELECTRICAL CONTRACTOR SHALL REFER TO AND VERIFY ALL INSTALLATION CONDITIONS AND FINAL DEVICE AND EQUIPMENT LOCATIONS WITH ARCHITECTURAL, MECHANICAL, PLUMBING & STRUCTURAL DRAWINGS PRIOR TO BID INCLUDE ALL FUNDINGS AND EXPENSES WITHIN THE BASE BID. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL EQUIPMENT, DEVICES, MATERIALS, LABOR AND ENERGIZING OF EQUIPMENT, OUTLETS AND DEVICES INDICATED OR SHOWN ON ALL CONTRACT DOCUMENTS. HE IS RESPONSIBLE FOR A COMPLETE AND FULLY FUNCTIONAL JOB. A3 PEERLESS CDM8-2-32-SBP-8FT-R4-277-GEB10-SCT- LP841-F2/24-ACG-0041 4 F032/841/XP/XL/ECo3 277 121 125 8' SUSPENDED DIRECT/INDIRECT FLUORESCENT BAFFLE LIGHT FIXTURE WITH 100% DOWNLIGHT FOR (4) LAMPS. SURFACE MOUNT TO UNISTRIT GRID. PROVIDE WITH ALL NECESSARY MOUNTING HARDWARE AND HANGERS, AND WITH ALL FITTINGS, ELBOWS, ETC. FOR A CONTINUOUS ROW OF FIXTURES, AND TANDEM MOUNTING KITS AS REQUIRED. ELECTRONIC BALLAST. UL LISTED.DALLAS, LIGHT FIXTURE FURNISHED BY OWNER, INSTALLED BY EC. WIRING, PROGRAMMING TESTING ETC. 3. CONTACT: TODD DEMPSEY 4325 ELM STREET SUITE 210 TEXAS 69526 TEL: 214-821-6958 FAX: 214-821-8769 BAS BUILDING AUTOMATION SYSTEM BFF BELOW FINISHED FLOOR BFG BELOW FINISHED GRADE BI BINARY INPUT BKR BREAKER BO BINARY OUTPUT BOS BOTTOM OF STRUCTURE N/C NORMALLY CLOSED NIC NOT IN CONTRACT NL NIGHT LIGHT N/O NORMALLY OPEN 0 OS OCCUPANCY SENSOR (� - ,1{) y.Y CO HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED TWIST -LOCK TYPE RECEPTACLE RECEPTACLE MOUNTED 6" ABOVE COUNTER OR BACKSPLASH CEILING MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE 8. ANY MENTION OF SPECIFIC VOLTAGE, LOAD, MOUNTING, ARRANGEMENTS, HEIGHTS, OR LOCATIONS ON ELECTRICAL DRAWINGS DOES NOT RELIEVE THE ELECTRICAL CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE SPECIFIC REQUIREMENTS PRIOR TO PURCHASE OR ROUGH -IN. COORDINATE SUPPLY VOLTAGE WITH MECHANICAL CONTRACTOR. 9. THE ELECTRICAL CONTRACTOR SHALL BALANCE THE PHASE LEGS OF ALL PANELS AND DISTRIBUTION SECTIONS INCLUDED IN CONTRACT WITHIN +10%. 10. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AND OPERATING ELECTRICAL SYSTEM. A4 PEERLESS ICDM8-2-32-SBP-8FT-R4-277-GEB10-SCT- LP841-F2/24-ACG-0041 4 F032/841/XP/XL/ECO3 277 121 125 8' SUSPENDED DIRECT/INDIRECT FLUORESCENT BAFFLE LIGHT FIXTURE WITH 100% DOWNLIGHT DISTRIBUTION FOR (4) LAMPS.C SURFACE MOUNT TO UNISTRIT GRID. PROVIDE WITH ALL NECESSARY MOUNTING HARDWARE AND HANGERS, AND WITH ALL FITTINGS, C CONDUIT CD CANDELA P P POLE ISOLATED GROUND (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) 11. ALL EXIT SIGNS AND EMERGENCY LIGHT FIXTURES SHALL BE IN STRICT ACCORDANCE WITH THE LOCAL AUTHORITIES AND FIRE PREVENTION CODE. PROVIDE ALL APPURTENANCES UNDER BASE BID TO COMPLETE AN OPERABLE SYSTEM. ALL EXIT SIGNS ARE TO BE INSTALLED PER THE NATIONAL FIRE PROTECTION AGENCY IN A VISIBLE LOCATION. THE ELECTRICAL CONTRACTOR SHALL TO DROP A SIGN BELOW ANY OBSTRUCTIONS. ELBOWS, ETC. FOR A CONTINUOUS ROW OF FIXTURES, AND TANDEM MOUNTING KITS AS REQUIRED. ELECTRONIC BALLAST. UL LISTED. DATA CT CURRENT TRANSFORMER PDU POWER DISTRIBUTION UNIT PH, PHASE EMERGENCY POWER (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) J.� GFCI FURNISH AND INSTALL ITEMS NECESSARY 12. REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND RATINGS OF EQUIPMENT AND DEVICES. THE CONTRACTOR PROVIDE WITH (1) END CAP LIGHT FIXTURE FURNISHED BY OWNER, INSTALLED BY EC.C 1. DATA CABLE AND JACKS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. SEE TCS SPECIFICATION CAN CABLE TELEVISION SYSTEM CCN CLOSED CIRCUIT TELEVISION PNL PANELHAS PNLBD PANELBOARD t RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: = CLOCK HANGER TYPE IG = ISOLATED GROUND E = EMERGENCY POWER GFCI = GROUND FAULT CIRCUIT INTERRUPTER SHALL FURNISH AND INSTALL ALL POWER AND CONTROL WIRING, CONDUITS, DEVICES, EQUIPMENT, MATERIALS AND LABOR TO PRODUCE A FULLY OPERATIONAL SYSTEM UNLESS OTHERWISE NOTED. B LIGHTOLIER XP-2-G-VA-2-32-UNV 2 F032/841/XP/XL/EC03 277 63 64 2'X4' GENERAL PURPOSE RECESSED (2) LAMP FLUORESCENT TROFFER WITH ACRYLIC LENS FOR T -BAR GRID CEILING. PROVIDE WITH ALL NECESSARY MOUNTING HARDWARE AND HANGERS. ELECTRONIC BALLAST. UL LISTED. LIGHT FIXTURE FURNISHED BY 2. ALL DATA CABLE SHALL BE CAT 6. CKT CIRCUIT CU COPPER D PT POTENTIAL TRANSFORMER Q QTY QUANTITY S = SWITCHED WP = WEATHERPROOF kA V TELEPHONE OUTLET - FLOOR OR WALL MOUNTED # 13. REVIEW THE MECHANICAL PLANS FOR THE POWER AND CONTROL REQUIREMENTS AND SCOPE OF WORK PRIOR TO BIDDING AND INCLUDE ALL COSTS IN BID. 14. VERIFY ALL FUSE SIZES AND TYPES WITH THE EQUIPMENT MANUFACTURER AND PROVIDE ACCORDINGLY. TENANT, INSTALLED BY EC. DDC DIRECT DIGITAL CONTROL DI DIGITAL INPUT R ►VA Q DATA OUTLET -FLOOR OR WALL MOUNTED * * 15. CONTRACTOR SHALL PROVIDE ALL CUTTING, CORE DRILLING AND PATCHING AS REQUIRED FOR THE WORK. B1 LIGHTOLIER XP-2-G-VA-2-32-UNV 2 F032/841/XP/XL/ECO3 277 63 64 SAME AS TYPE "B" EXCEPT ON EMERGENCY INVERTER. (11350 LUMENS DN DOWN DPDT DOUBLE -POLE, DOUBLE -THROW DPST DOUBLE -POLE, SINGLE -THROW RCPT RECEPTACLE REV REVISION RLA RUNNING LOAD AMPS \I 7 TELE/DATA OUTLET - FLOOR OR WALL MOUNTED *INSTALL TELE/DATA OUTLET AT SAME ELEVATION AS ADJACENT POWER RECEPTACLE, LINO. # INDICATES NUMBER OF CAT 6 16. VERIFY CONNECTION POINTS TO ALL HVAC EQUIPMENT PRIOR TO INSTALLATION. INCLUDE COSTS FOR THIS VERIFICATION WITHIN THE BASE BID. 17. PROVIDE FIRE GYPSUM BOARD ENCLOSURES AROUND ALL FIXTURES WHICH PENETRATE FIRE -RATED AREAS OR IN RETURN C4 FONTANA ARTE AMAX 'CHARLES WILLIAMS' #5444 PROVIDE FACTORY MAX. WATTAGE LABEL WITH 450 MAX. WATTS PER FIXTURE 3 150W E-27 FROSTED LAMPS 120 450 450 42" DIA. X 34.5" TALL DECORATIVE PENDANT LIGHT WITH WHITE SHADE, PENDANT/CABLE HUNG -WITH STEEL SUSPENSION CABLE FIXTURE TO BE MOUNTED AT 9'-0" TO THE BOTTOM OF THE FIXTURE UL LISTED. LIGHT FIXTURE FURNISHED BY TENANT, INSTALLED BY EC. E EPO EMERGENCY POWER OFF ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLERCONTACTOR RPM REVOLUTIONS PER MINUTE s SD SMOKE DETECTOR LES AND OUTLETS AT THAT LOCATION. PROVIDE A MAXIMUM CABOF LE(4CAT 6 CABLES PER Q) / I MULTI -SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER OUTLETS -RATED AIR PLENUMS. ALL FIXTURES SHALL BE RATED FOR COVERED OPERATION 18. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AN IN-LINE FUSE FOR ALL STARTER AND CONTACTOR COILS, (APPROPRIATELY SIZED FOR THE INDIVIDUAL COIL LOAD). THE FUSE AND FUSE HOLDER SHALL BE LOCATED INSIDE THE ENCLOSURE ADJACENT TO THE COIL. C5 ARTEMIDE FLOAT -C SUSPENSION (#0367018 CUSTOM BLUE FILTER #721) 1 2GX13/T5 CIRCULINE (T 16 R FLUORESENT) (3000 Kelvin) 120 55 59 DECORATIVE PENDANT LIGHT WITH PAINTED ALUMINUM SHADE, OPALINE LOWER DIFFUSER, TRANSPARENT UPPER DIFFUSER. FIXTURE PROVIDED WITH LAMPING AS INDICATED. UL LISTED. LIGHT FIXTURE FURNISHED BY TENANT, INSTALLED BY EC. SECURE BLUE FILTER WITH TWO SIDED TAPE. FIXTURE SHALL BE ORIENTATED SO THAT THE "C" SHAPED LAMP EC ELECTRICAL CONTRACTOR F FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS/OWNER FFA FROM FLOOR ABOVE SPOT SINGLE -POLE, DOUBLE -THROW SPST SINGLE -POLE, SINGLE -THROW SWBD SWITCHBOARD T TC/C TEMPERATURE CONTROLS CONTRACTOR A A = TYPE A, SEE SCHEDULE 1B Q JUNCTION BOX/OUTLET BOX O THERMOSTAT MULTI SURFACE RACEWAY WITH NEMA 5-20R 19. ALL CONDUIT SHALL BE INSTALLED CONCEALED WHERE POSSIBLE. ALL DEVICE OPENING COVERPLATES SHALL BE FLUSH WITH FINISHED SURFACES UNLESS OTHERWISE NOTED. 20. MINIMUM SIZE OF HOMERUN CONDUITS SHALL BE 3/4" CONDUIT. 21. ALL CONDUITS SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO WALLS & STRUCTURAL MEMBERS AND SHALL BE RACKED IMAGE IS FACING TOWARDS THE RIGHT (AS YOU WALK IN FROMTCS THE EXTERIOR AND IMMEDIATELY LOOK UP). FFB FROM FLOOR BELOW FF FINISHED FLOOR THE CONTAINER STORE TFA TO FLOOR ABOVE TFB TO FLOOR BELOW -OUTLET RECEPTACLES 12 ON CENTER, UNO WITH 90 DEGREE BEND WHERE REQUIRED, JUNCTION AND PULL BOXES SHALL BE HELD TO A MINIMUM. ALL SUPPORTS SHALL BE MADE FROM THE STRUCTURE. NO CONDUIT SHALL BE RUN EXPOSED HORIZONTALLY ON WALLS, CONDUIT MUST BE RUN AS HIGH AS POSSIBLE WITH VERTICAL DROPS. CONCEAL CONDUIT WHEREVER POSSIBLE AND WHERE INDICATED. C6A C6B 3G LIGHTING 3G-PKU1004V 2F28 277 E WH -11'-O" 3G-PKU1004V 2F28 277 E WH -14'-4" 2 F28T5- 3500K 277 64 66 49.75" LARGE PENDANT WITH WHITE SANDBLASTED ACRYLIC DIFFUSER, FABRICATED WITH MITERED CORNERS FLA FULL LOAD AMPS FLR FLOOR FVNR FULL -VOLTAGE, NON -REVERSING TL TWISTLOCK 1T TEMPERATURE TRANSMITTER 04111 WIRELESS ANTENNA 22, CONDUITS AND ELECTRICAL RACEWAYS SHALL NOT BE SUPPORTED NOR ATTACHED TO SUSPENDED CEILING T -BARS OR CEILING SUPPORT WIRES. C6C 3G-PKU1004V 2F28 277 E WH -12'-8" 277 E WH CONTRACTOR SHALL ORDER CABLE LENGTHS BASED ON DIMEINSION HEIGHT TO THE BOTTOM OF EACH FIXTURE ON G TX TRANSFORMER CIRCUITING & WIRING 23. CONDUIT SHALL HAVE A MAXIMUM OF FOUR (4) 90' BENDS BETWEEN JUNCTION PULL BOXES, JUNCTION BOXES SHALL BE SIZED PER N.E.C. SEC. 370 AND SHALL BE A MAXIMUM OF 200 FT. APART. CGD C6F C6G C6H 3G-PKU1004V 2F28 -16'-O" 3G-PKU1004V 2F28 277 E WH -15'-2" 3G-PKU1004V 2F28 277 E WH - 11-10" 3G-PKU1004V 2F28 277 E WH - 13'-6" SHEET E-2.0. GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFR GROUND FAULT RELAY G, GND GROUND TYP TYPICAL U U/F UNDERFLOOR 7 5 3 HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER OF CIRCUITS, P1 HASH MARKS INDICATE NUMBER OF CONDUCTORS; INFORMATION AT ARROWS ARE CIRCUIT NUMBERS AND PANELBOARD. OR 7P1-3,5,7 24. ALL EMT TYPE FITTINGS SHALL BE STEEL OR CAST COMPRESSION GLAND TYPE, OR SET SCREWS 25. ALL FITTINGS, FASTENERS, STRAPS, ETC. MUST BE GALVANIZED STEEL. CADDY TYPE CLIPS WILL BE PERMITTED. ALL OUTLETS AT 18" AFF, U.O.N. D AEI LIGHTING T8L-HB-PS-4-32-P-NL-27-41-WG 12'-O" CORD NO PLUG E 4 F032/841/XP/XL/EC03 277 121 125 ENERGY-EFFICIENT LOW -BAY LIGHT FIXTURE FOR (4) FLUORESCENT LAMPS. PROVIDE WITH ALL NECESSARY MOUNTING HARDWARE AND HANGERS. CHAIN HUNG AT +15'-O" TO BOTTOM OF FIXTURE. VERIFY MOUNTING HEIGHT WITH OWNER PRIOR TO INSTALLATION. PROVIDE WIRE GUARD. ELECTRONIC BALLAST. UL LISTED. LIGHT FIXTURE FURNISHED BY TENANT, INSTALLED BY EC. GWB GYPSUM WALL BOARD I IG ISOLATED GROUND J u/G UNDERGROUND UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY V V VOLTS) �� EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION OR BARE) ....---3-""... ISOLATED GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION WITH YELLOW STRIPE) 26. 27. NO CONDUIT SHALL BE RUN THROUGH HVAC AIR HANDLING DUCTS. 28. PROVIDE SEPARATE ISOLATED GROUND FOR EACH CIRCUIT SERVING I.G. RECEPTACLES. 29. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A GROUND WIRE IN ALL CONDUIT, GROUND WIRES MAY NOT BE SHOWN, BUT SHALL BE INCLUDED WITHIN THE ELECTRICAL CONTRACTOR'S BASE BID. D1 AEI LIGHTING T8L-HB-PS-4-32-P-NL-27-41-WG-OC 12'-O" CORD NO PLUG PROVIDE WITH WHITE CORD 4 F032/841/XP/XL/EC03 277 121 125 ENERGY-EFFICIENT LOW -BAY LIGHT FIXTURE FOR (4) FLUORESCENT LAMPS. PROVIDE WITH ALL NECESSARY MOUNTING HARDWARE AND HANGERS. CHAIN HUNG AT +15'-O" TO BOTTOM OF FIXTURE. VERIFY MOUNTING HEIGHT WITH OWNER PRIOR TO INSTALLATION. WITH FACTORY -MOUNTED OCCUPANCY SENSOR JB, J -BOX JUNCTION BOX K kcmil 1000 CIRCULAR MILS kV KILOVOLT VAC VOLTS ALTERNATING CURRENT VDC VOLTS DIRECT CURRENT W W WIRE �1 CONDUIT CONCEALED i --- CONDUIT IN UNDER FLOOR GROUND CONSTRUCTION / FLOOR/GROUND 30. ALUMINUM CONDUIT AND CONDUCTORS ARE NOT APPROVED FOR USE. 31. FLEXIBLE METAL TUBING WILL NOT BE ALLOWED. 32• FLEXIBLE METAL CONDUIT (GREENFIELD) AND LIQUID TIGHT METAL CONDUIT (SEALTITE) SHALL HAVE A MAXIMUM LENGTH OF 6'-O" SIZE oaa AND WIRE GUARD. ELECTRONIC BALLAST. UL LISTED. LIGHT FikTURE FURNISHED BY TENANT, INSTALLED BY EC. ft. kVA KILOVOLT -AMPS kVAR KILOVOLT -AMPS REACTIVE kW KILOWATT W/ WITH W/0 WITHOUT EXPOSED CONDUIT ..../..\,.... 'e FLEXIBLE CONDUIT AND SHALL INCLUDE A GROUND CONDUCTOR. MINIMUM IS 3/4". 33. IF ALLOWED BY AHJ MC CABLEt ARE ACCEPTABLE PROVIDED IT IS COMPLETELY CONCEALED. NO EXPOSED MC. IF MC CABLE IS USED FOR ISOLATED GROUND CIRCUITS PROVIDE TYPE WITH TWO GROUND WIRES, AC OR ROMEX TYPE WIRING IS NOT ALLOWED. DIE AEI LIGHTING T8L-HB-PS-4-32-P-NL-27-41-WG-OC 4 F032/841/XP/XL/EC03 277 121 125 SAME AS TYPE "D1" EXCEPT ON EMERGENCY INVERTER. (1350 LUMENS) kWH KILOWATT-HOUR L WP WEATHERPROOF XWHERE /LV\ LOW VOLTAGE CABLE 34. ALL JUNCTION OR PULL BOXES ABOVE THE SUSPENDED LAY -IN CEILINGS SHALL BE MOUNTED ±1'-0" ABOVE THE CEILING LINE, POSSIBLE, AND IN AN ACCESSIBLE LOCATION. 12'-0" CORD NO PLUG WHITE CORD LRA LOCKED ROTOR AMPS XFMR TRANSFORMER POWER EQUIPMENT & DEVICES 35. CONDUITS AND JUNCTION BOXES IN EXPOSED AREAS SHALL BE INSTALLED AS HIGH AS POSSIBLE AND ABOVE ALL LIGHTING. E JUNO TC922LED-3K-2 HOUSING 1 LED (INCLUDED) 277 26 26 6" RECESSED CLEAR -LENSED DOWNLIGHT. PROVIDE ALL MOUNTING HARDWARE AND HANGERS, CLEAR ALZAK REFLECTOR, WHITE TRIM. XP EXPLOSION -PROOF THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNCRATING, STORING, SETTING s ELECTRICAL PANELBOARD (SURFACE OR FLUSH MOUNT)36. FOR EQUIPMENT OR 27C -WH TRIM CEILING ELECTRONIC BALLAST. UL LISTED. LIGHT FIXTURE FURNISHED BY TENANT, INSTALLED BY EC. NOTE: FOR LIGHT FIXTURES LOCATED UTILITY, LANDLORD CONTACTS, AND REQUIREMENTS IN PLACE AND PROTECTING FROM DAMAGE, VANDALISM, THEFT, OR WEATHER DURING CONSTRUCTION ALL NEW SALVAGED EXISTING EQUIPMENT STORED BETWEEN BEING RELOCATED. PROVIDE ADAPTER KIT FOR SLOPED AT CURVED CEILING, FIXTURES MUST BE SUPPLIED WITH LARGER 1. ELECTRICAL CONTRACTOR SHALL VERIFY ALL REQUIREMENTS AND POINTS OF O )0 TERMINAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED 37. ALL PENETRATIONS THRU FLOORS AND FIRE RATED ASSEMBLIES SHALL BE SEALED WITH U.L. LISTED FIRESTOP. TRIM RING TO OFFSET CEILING CURVE. COORDINATE LOCATIONS CONNECTION WITH LANDLORD & UTILITIES. CONTRACTOR SHALL MAKE �////, ELECTRICAL DISTRIBUTION PANELBOARD WITH PROJECT MANAGER. DAMP LOCATION LISTED. R.ON TCSTYPE ARRANGEMENTS FOR SERVICE AND PAY REQUIRED FEES. PROVIDE ALL FEES 38. ONLY RECEPTACLES INDICATED FOR GFI PROTECTION SHALL BE SO PROTECTED. El JUNO 1 LED (INCLUDED) 277 26 26 "E" EXCEPT EMERGENCY INVERTER. SAME ASTYPLUMENS) & APPURTENANCES REQUIRED BY THE LANDLORD & UTILITY COMPANIES FOR /////////, SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD TC922LED-3K-2NOHOUSING, 27C -WH TRIM PROVIDE KIT FOR SLOPED CEILING PROVIDING SERVICE TO THE PROJECT. CONTRACTOR SHALL CONTACT THE TERMINAL FOR TELEPHONE SYSTEM LINO NOTED 39. THE PLANS AND SPECIFICATIONS ARE COMPLIMENTARY TO EACH OTHER AND WHAT IS CALLED FOR BY ONE SHALL BE BINDING AS G5 ADAPTER JUNO TM-214-39EMH-WH (PROVIDE WITH T4OF MONOPOINT CANOPY Sc 4-0 BOX WHERE NOT MOUNTED ON TRACK WHITE 1 MASTERColour CDM -T MH39W/T6 3000K 42" FLOOD G12 BI -PIN BASE 120 46 50 MONOPOINT MOUNTED, ADJUSTABLE LIGHT FIXTURE WITH (1)METAL HALIDE LAMP. INTERGRAL ELECTRONIC BALLAST. PROVIDE ALL CONNECTORS AND OTHER ACCESSORIES FOR A COMPLETE LIGHTING SYSTEM. REFER TO 1/E-2 FOR QUANTITIES AND LOCATIONS. UL LISTED. FURNISHED BY TENANT, INSTALLED BY E.C. UTILITIES IMMEDIATELY AND SHALL BE RESPONSIBLE FOR THE COORDINATION OF SERVICES WITH THE LANDLORD AND,UTILITIES. 2. VERIFY ALL SERVICE REQUIREMENTS WITH UTILITY COMPANIES & LANDLORD AND INCLUDE IN THIS CONTRACTOR'S BID TO PAY FOR ALL RELATED EXPENSES REQUIRED. e PLYWOOD BOARD SIZE AS so 3/35 DISCONNECT SWITCH - "60/3/35" DENOTES AMPERES/POLE/FUSE NF= NON-FUSED CB= CIRCUIT BREAKER (35/3/CB) 30 3/15/1 COMBINATION DISCONNECT (SAFETY) SWITCH AND MOTOR STARTER "30/3/15/1" DENOTES AMPERES/POLE/FUSE/NEMA STARTER SIZE IF CALLED FOR BY BOTH. 40• ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE WEATHRPROOF. 41. ALL PROTECTIVE DEVICES (INCLUDING CIRCUIT BREAKERS, FUSED SWITCHES, COMBINATION MOTOR STARTERS, ETC.) SHALL HAVE AN INTERRUPTING CAPACITY EQUAL TO OR EXCEEDING THE AVAILABLE FAULT CURRENT. G6 JUNO TM -256 -39 -WH WITH T43WH AND 4-0 BOX WHITE 1 MASTERColour CDM -T MH39W/T6 3000K 42" FLOOD 120 46 50 MONOPOINT MOUNTED ADJUSTABLE WALL WASH LIGHT FIXTURE FOR (1) METAL HALIDE LAMP. INTEGRAL ELECTRONIC BALLAST. GLASS LENS INCLUDED WITH FIXTURE. PROVIDE ALL CONNNECTORS AND OTHER ACCESSORIES FOR A COMPLETE LIGHTING SYSTEM. REFER TO 1/E-2 FOR QUANTITIES AND LOCATIONS. UL LISTED. 3. VERIFY ALL EXISTING SITE CONDITIONS AND COORDINATE ALL SERVICE REQUIREMENTS WITH UTILITY COMPANIES AND LANDLORD. NF= NON-FUSED CB= CIRCUIT BREAKER (30/3/CB/1) 4D- MOTOR 11 MANUAL STARTER 42. ALL WORK SHALL BE PERFORMED INA NEAT WORKMAN LIKE MANNER. 43. LIGHTING FIXTURE NUMBERS, VOLTAGES, AND LAMP TYPES ON THE LIGHTING FIXTURE SCHEDULE SHALL BE USED AS CRITERIA FOR PRODUCING MINIMUM REQUIREMENTS ON THIS JOB. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PROPER VOLTAGES, NUMBERS, LAMP TYPES AND MOUNTINGS. 012 BI -PIN BASE 44. CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL IN WALL CONDUITS WITH TENANT. G7 JUNO TRACK 12/25 TRACK SYSTEM TLRBWH - TRACK (LENGTH PER PLANS) 1 GE LIGHTING 7W LED MR16 LED7XDMR16830/25 277/12 7W PER LAMP 7VA PER LAMP LOW VOLTAGE TRACK LIGHTING SYSTEM FOR 12V MR16 TRACK LIGHT FIXTURES. VERIFY NUMBER OF TRACK LIGHT FIXTURES WITH TCS PROJECT MANAGER. PROVIDE LAMPS WITH NARROW FLOOD =1 MAGNETIC MOTOR STARTER, NEMA SIZE AND NUMBER OF POLES AS NOTED D PUSH BUTTON 45. CONTRACTOR SHALL PROVIDE ALL WIRE, CONDUIT, J -BOXES AND ALL OTHER APPURTENANCES NECESSARY FOR THE COMPLETE INSTALLATION OF BUILDING MOUNTED SIGNS. MAKE ROUGH -IN AND FINAL ELECTRICAL CONNECTION TO SIGN. TLR38WH - END COVER (2 PER TRACK) DISTRIBUTION. AIM TRACK LIGHT FIXTURES TO EVENLY ILLUMINATE EQUIPMENT AND SYSTEMS m STOP -START PUSH BUTTON CONTROL STATION TLR23WH - TRACK JOINER TF5600BL-277 - REMOTE LV TRANSFORMER TL116WH - TRACK HEAD TLRW12 - 12" TRAC EXTENSION WANDS BANNERS AT WINDOWS. PROVIDE TRACK LENGTHS PER PLANS. PROVIDE WITH WHITE FINISH FOR ALL COMPONENTS. PROVIDE WITH REMOTE LOW VOLTAGE TRANSFORMER, AS INDICATED. COORDINATE LOCATION WITH TCS PROJECT MANAGER. PROVIDE ALL ADDITIONAL SYSTEM COMPONENTS AND ACCESSORIES FOR A GENERAL CONTRACTOR SHALL COORDINATE MID SCHEDULE THE START_UP OF VARIOUS AS FOLLOWS: 1. POWER WALL: CONTACT APPROVED VENDOR #15 AT LEAST ONE-MONTH PRIOR TO TURN OVER TO SCHEDULE COMMISSIONING AND START-UP OF POWER WALL. PROVIDE FULL FACTORY START-UP AND EI -D MUSHROOM -TYPE PUSH BUTTON PC PHOTOCELL GENERAL INSTALLATION NOTES COMPLETE SYSTEM, I.E. END CAPS, MOUNTING HARDWARE, AND HANGERS, ETC. UL LISTED. FURNISHED BY TENANT, INSTALLED BY E.C. COMMISSIONING OF POWER WALL UNIT INCLUDING COMMISSIONING REPORT FROM MANUFACTURER. 2. INVERTER: CONTACT APPROVED VENDOR #22 AT LEAST ONE-MONTH PRIOR TO TURN OVER TO SCHEDULE COMMISSIONING AND START-UP OF INVERTER. PROVIDE FULL FACTORY START-UP AND C MAGNETIC CONTACTOR SIZE, COIL VOLTAGE AND NUMBER OF POLES AS INDICATED (L= LIGHTING CONTACTOR P= POWER CONTACTOR) 1. ALL CONDUIT STUBS SHALL HAVE PROTECTIVE BUSHINGS. 2. PROVIDE COVER PLATES FOR POWER, COMMUNICATION AND LIGHT SWITCHES PER GENERAL NOTE 1 SHEET A-1.4 ALL WHITE G9 GE TETRA AL10 LPL -W18 -120D-940 1 LED (INCLUDED) 277 7.5VA PER 7.5VA PER LINEAR LED LIGHT FIXTURE SYSTEM. PROVIDE ALL CONNECTORS AND OTHER ACCESSORIES FOR A COMPLETE LIGHTING SYSTEM COMMISSIONING OF INVERTER UNIT INCLUDING COMMISSIONING REPORT FROM MANUFACTURER. TS TIME SWITCH NYLON INCLUDING TOILET ROOMS. FIX. FIX. REFER TO 1/E-2 FOR QUANTITIES AND LOCATIONS. UL LISTED. 3. UPS: CONTACT APPROVED VENDOR #16 AT LEASE ONE-MONTH PRIOR TO TURN OVER TO SCHEDULE UPS LDIN START-UP UPS. PROVIDE FULL FACTORY STARE -UP AND COMMISSIONING OF LIGHTING 3. MATERIAL, EQUIPMENT, AND INSTALLATION SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THE PERIOD SHALL BE REPAIRED/ADJUSTED/CORRECTED AT THE K LITHONIA 2 F032/841/XP/XL/ECO3 277 63 64 4' GENERAL PURPOSE STRIP LIGHT FIXTURE FOR (2) FLUORESCENT UPS UNIT INCLUDING COMMISSIONING REPORT FROM MANUFACTURER. UNITNIO CONTRACTOR'S EXPENSE, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN TC-232-MVOLT-GEB1ORS-WGCUNST-HC36 LAMPS. PROVIDE WITH WIRE GUARD ACCESSORY AND ALL NECESSARY MOUNTING HARDWARE AND HANGERS. ELECTRONIC 4. ROOFTOP EQUIPMENT: REFER TO NOTES ON MECHANICAL DRAWINGS FOR SPECIFIC INFORMATION ON THE Aa FLUORESCENT LIGHT FIXTURE: (SEE LIGHT FIXTURE SCHEDULE) TO SWITCH "a" WORKMANSHIP OR MATERIAL FURNISHED DURING THE SAME PERIOD. PROGRAMMABLE RAPID START BALLAST. VERIFY MOUNTING START-UP AND COMMISSIONING OF THE ROOFTOP EQUIPMENT. CONTACT ENTEK AT LEAST ONE = SWITCHED I 0 I A LIGHT FIXTURE TYPE "A" 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EQUIPMENT AND SYSTEMS AGAINST HARMFUL EXPOSURE, OR HEIGHT WITH TENANT PRIOR TO INSTALLATION. UL LISTED. FURNISHED BY TENANT, INSTALLED BY EC. MONTH PRIOR TO STARTING UNITS TO SCHEDULE COMMISSIONING AND START-UP OF ROOFTOP EQUIPMENT. PROVIDE FULL START-UP AND COMMISSIONING OF ROOFTOP EQUIPMENT INCLUDING = ® ACCUMULATION OF DIRT/MOISTURE, FLOODING, CORROSION, OR OTHER FORMS OF DAMAGE. CLEAN AND RESTORE DAMAGED FINISHES AND EQUIPMENT TO PLACE INSTALLATION IN A LIKE -NEW CONDITION. K1 LITHONIA 2 F032/841/XP/XL/ECo3 277 63 64 SAME AS TYPE "K" EXCEPT ON EMERGENCY INVERTER. COMMISSIONING REPORT FROM ENTEK AND DIVCON EMS. LIGHT FIXTURE - CEILING WALL MOUNTED 09 / C-232-MVOLT-GEB1ORS-WGCUNST-HC36 (1350 LUMENS) (SEE LIGHT FIXTURE SCHEDULE) 5. ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED AND TESTED FOR PROPER OPERATION. AFTER WIRES ARE IN PLACE AND LIGHTING TRACK WITH HEADS AS INDICATED SHALL BE TESTED FOR SHORTS AND GROUNDS. ALL HOT AND L SWING -ARM DOCKUTE DL-16LED-LH (LIGHT HEAD) DL -42 -ARM -DS (DOUBLE -STRUT ARM) 1 16W LED (INCLUDED) 120 16 16 WALL MOUNTED SWING -ARM DOCK LIGHT FIXTURE WITH LED HEAD. PROVIDE WITH ALL NECESSARY MOUNTING HARDWARE. ELECTRONIC BALLAST. UL LISTED. FURNISHED BY TENANT, INSTALLED BY EC. GENERAL CONTRACTOR SWILL PROVIDE AND MAKE AVAILABLE TO THE CONTAINER STORE. THE PROJECT SUPERINTENDENT AND THE FOLLOWING TRADES. FOR ONE FULL DAY. NEAR THE END OF PUNCH UST. (DATE TO BE SCHEDULED BY AND COORDINATED WITH THE CONTAINER STORE PROJECT MANAGER). FOR IT CUT -OVER. TESTING. AND SUPPORT: (SEE LIGHT FIXTURE SCHEDULE) ® EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED (SEE LIGHT FIXTURE SCHEDULE) CONNECTED TO DEVICES AND EQUIPMENT, THE SYSTEM NEUTRAL CONDUCTORS, IF SHORTED OR GROUNDED SHALL BE REMOVED AND REPLACED. ALL METERS, INSTRUMENTS, CABLE CONNECTIONS, EQUIPMENT OR APPARATUS NECESSARY FOR MAKING ALL TESTS, SHALL BE FURNISHED BY THIS CONTRACTOR AT HIS OWN EXPENSE. M INDY MSS3O-F-F-F-10-40-WH1 3 LUMILEDS LUXEON REBEL LED (INCLUDED) 277 68 75 RECESSED ADJUSTABLE LIGHT FIXTURE FOR (3) LED LAMPS. PROVIDE ALL NECESSARY MOUNTING HARDWARE AND HANGERS. UL LISTED. FURNISHED BY BY OWNER, INSTALLED BY EC. 1. AN ELECTRICIAN FROM THE PROJECT'S ELECTRICAL SUBCONTRACTOR'S INSTALL TEAM ON SITE TO TROUBLE SHOOT ALL TCS IT INSTALLATION TEAM'S ADDITIONAL PUNCH LIST ITEMS DISCOVERED ON THE ELECTRICAL SYSTEMS. poi EMERGENCY BATTERY PACK LIGHT FIXTURE - CEILING / WALL MOUNTED (SEE LIGHT FIXTURE SCHEDULE) 6. TOUCH-UP OR REFINISH DAMAGED SURFACES OF FIXTURES AND EQUIPMENT. 7. CONCEAL WIRING SYSTEM ABOVE SUSPENDED CEILINGS OR IN WALL OR FLOOR CONSTRUCTION WHERE POSSIBLE. INSTALL CONDUIT PARALLEL TO BUILDINGS LINES AND TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS, STRUCTURE, ETC. N4 MARK ARCHITECTURAL LIGHTING SL2 4' 1 L35 UNIV EDVR 120 FA(2ND FLOOR) 1 LED (INCLUDED) 120/24V 75W MAX. 75W MAX LED LINEAR 2" SLOT WITH SNAP -IN CLEAR FROSTED ACRYLIC LENS PROVIDE 120V INPUT AND 24V OUTPUT DRIVER(MAX 75 WATTS) 2. A SYSTIMAX CERTIFIED TECHNICIAN FROM THE PROJECT'S DATA SUBCONT'RACTOR'S INSTALL TEAM ON SITE TO TROUBLE SHOOT ALL TCS IT INSTALLATION TEAM'S ADDITIONAL PUNCH UST ITEMS FIRE ALARM AUDIO / VIDEO EXPOSED CONDUIT SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO STRUCTURE AND AS HIGH AS POSSIBLE. COORDINATE ROUTING WITH TCS PRIOR TO INSTALLATION, MINIMIZE CROSSINGS AT AREA WITHOUT UNISTRUT GRID. N9 N26 SL2 9' 1 L35 UNIV EDVR 120 FA(2ND FLOOR) SL2 26' 1 L35 UNIV EDVR 120 FA(1ST FLOOR) DISCOVERED ON THE DATA PLANT INSTALLATION. 3. A DMCON BAS TECHNICIAN FROM THE BAS INSTALL TEAM ON SITE TO: CUT OVER THE BAS FROM "STAND ALONE' TO "INTEGRATED WITH THE ITB F WHITE FIRE ALARM PULL STATION O CEILING MOUNTED SPEAKER 8. INSTALL CONDUIT CONTINUOUS BETWEEN BOXES AND CABINETS WITH NO MORE THAN FOUR (4) 90 DEGREE BENDS, P TO BE DETERMINED 1 TBD 120/12 BACK -LIT GRAPHIC DISPLAY BOXES (50 1/2"X50 1/2") a. SERVERS/ROUTERS/SWITCHES" b. FINALIZE THE BAS AUTOMATIC UGHTING CONTROLS WITH THE ADT SECURITY SYSTEMS G FINALIZE AND TROUBLE SHOOT ALL BAS SYSTEMS INCLUDING CORPORATE CONTROLLED HVAC 1=1:1 u WHITE STROBE LIGHT 110 • SIGNALING BELL EN SIGNALING BUZZER SECURELY FASTENED IN PLACE WITH STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. DO NOT SUPPORT CONDUIT FROM SUSPENDED CEILING GRID OR SUSPENSION WIRES. REAM CONDUIT ENDS BEFORE INSTALLATION AND THOROUGHLY CLEAN BEFORE INSTALLATION. OPENINGS SHALL BE PLUGGED OR COVERED TO KEEP CONDUIT CLEAN. TERMINALS ON "FEED-THRU" R JUNO - MINI LED MD1L 35K FL WH 1 LED (INCUDED)CONTROLS. 120/12 4.8 4.8 2 1/4" DIA APERTURE MINI LED DOWNLIGHT E.C. SHALL PROVIDE XFMR Juno#TL6O2E-60-WH DOOR ACCESS AND LIGHTING CONTROLS. 4. GENERAL CONTRACTOR IS TO SCHEDULE AND COORDINATE THE ADT INSTALLATION SUBCONTRACTOR ®Q WHITE COMBINATION HORN/STROBE C,115 "C" T LV TRANSFORMER SWITCHES AND RECEPTACLES SHALL NOT BE USED TO TO THE NEXT SWITCH OR RECEPTACLE. THE DISCONNECTING OR REMOVAL OF A DEVICE FROM A BOX SHALL NOT INTERFERE WITH OR INTERRUPT THE CONDUCTOR CONTINUITY. X -1-A LITHONIA 1 LED (INCLUDED) 277 5 5 LED EXIT SIGN. SINGLE FACE WITH RIGHT DIRECTIONAL ARROWS, (APPROVED VENDOR #4) TO BE ON SITE TO FINALIZE THE CONNECTIONS OF THE ADT KEYPAD INDICATES CEILING MOUNTED EDGE -LIT EXIT SIGN LRP -W -1 -GC -RA -120/277 -EL -N GREEN LETTERS WITH WHITE HOUSING. FURNISH WITH BRACKET FOR TOP RECESSED MOUNTING. FURNISH ALL NECESSARY MOUNTING OVERRIDES WITH THE UGHTING CONTROLS PROVIDED BY DIVCON (SEE ABOVE). ADT WILL ALSO "COMMISSION" TRAINING) TO THE TCS IT H1 ss• WHITE HEAT DETECTOR SECURITY 9. ALL FLUORESCENT LIGHTING FIXTURES INSTALLED IN SUSPENDED CEILING SHALL BE SUPPORTED FROM THE STRUCTURE, DUCTWORK AND PIPING & SECURE TO CEILING. • HARDWARE AND HANGERS. WIRE TO EMERGENCY CIRCUIT AS SHOWN ON DRAWINGS. MAINT. FREE NI -CAD BATTERY PACK AND TEST SWITCH. UL LISTED, FURNISHED BY TENANT, INSTALLED BY EC, FURNISHED BY TENANT, INSTALLED BY EC. THE BURGLAR ALARM SYSTEM AND TURN OVER (INCLUDING PERSONNEL ON SITE. 5. GENERAL CONTRACTOR IS TO SCHEDULE AND COORDINATE THE MOOD MEDIA INSTALLATION SUBCONTRACTOR (APPROVED VENDOR #5) TO BE ON SITE TO FINALIZE THE CONNECTIONS OF THE SOUND SYSTEM WITH THE PATTING COMPONENTS OF THE IT SYSTEMS. S SD WHITE SMOKE DETECTOR SD = MOUNTED IN SUPPLY DUCT RD = MOUNTED IN RETURN DUCT GS TAMPER SWITCH DC DOOR CONTACT 04 FIXED CAMERA IN DOME INDEPENDENT OF THE CEILING SYSTEM, 10. ALL EMPTY CONDUITS SHALL HAVE PULLSTRINGS. 11 • ALL CONDUIT PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH FIRESTOP PER APPLICABLE U.L. DETAIL. X -1-B LFTHONIA EDGE -LIT EXIT SIGN 1 LED (INCLUDED) 277 5 5 LED EXIT SIGN. SINGLE FACE WITH LEFT DIRECTIONAL ARROW. GREEN LETTERS WITH WHITE HOUSING. FURNISH WITH BRACKET FS FLOW SWITCH p41 PTZ 360 CAMERA IN DOME LRP -W -1 -GC -LA -120/277 -EL -N FOR TOP RECESSED MOUNTING. FURNISH ALL NECESSARY MOUNTING HARDWARE AND HANGERS. WIRE TO EMERGENCY CIRCUIT AS SHOWN ON DRAWINGS. MAINT. FREE NI -CAD BATTERY PACK AND TEST SWITCH. UL LISTED, FURNISHED BY TENANT, INSTALLED BY EC, FURNISHED BY TENANT, INSTALLED BY EC. �R�VI���®F�f� ' NOTE: X -1-C LITHONIA EDGE -LIT EXIT SIGN LRP -W -1 -GC -120/277 -EL -N 1 LED (INCLUDED) 277 5 5 LED EXIT SIGN, SINGLE FACE WITH NO DIRECTIONAL ARROWS, RECESSED BACK MOUNTING. GREEN LETTERS WITH WHITE HOUSING FURNISH ALL NECESSARY MOUNTING HARDWARE AND HANGERS. WIRE TO EMERGENCY CIRCUIT AS SHOWN ON DRAWINGS. SELF W w w VERTICALLY ALIGN ANY DEVICES WITHIN 2'-0" HORIZONTALLY OF EACH OTHER,TYPTHRU-OUT � '� �� ___ _ TESTING/DIAGNOSTIC. UL LISTED. FURNISHED BY TENANT, INSTALLED BY EC. 0 LINE OF CEILING q $ JUt--LO�� �. X -2-D LITHONIA 1 LED (INCLUDED) 277 5 5 LED EXIT SIGN. DOUBLE FACE WITH LEFT/RIGHT DIRECTIONAL ALL DEVICES TO ALIGN LEGEND; d EDGE -LIT EXIT SIGN ARROW. GREEN LETTERS WITH WHITE HOUSING. FURNISH WITH SCHEDULED SIGN VERTICALLY -EYP. ALL LOCATIONS. s LRP-W-2-GMR-DA-122/277-EL-N BRACKET FOR TOP RECESSED MOUNTING. FURNISH ALL NECESSARY TEMPERATURE SENSOR 80"A.F.F. D �'► f®s-�e,lU,aII "' �`y i YAM 1i� MOUNTING HARDWARE AND HANGERS. WIRE TO EMERGENCY CENTERLINEEl CENTERLINE CIRCUIT AS SHOWN ON DRAWINGS. MAINT. FREE NI -CAD BATTERY "EQ' -EQ.' © 6" MAX. - -12'rnAx. SECURITY BADGE READER, 48"A.F.F. © BUILDING DIVISION PACK AND TEST SWITCH. UL LISTED. FURNISHED BY TENANT, INSTALLED BY EC. CARD SWIPE, OR KEYPAD I 1 LIGHT SWITCH 48"A.F.F. © " X -1-F LITHONIA 1 LED (INCLUDED) 277 5 5 LED EXIT SIGN. SINGLE FACE WITH LEFT AND RIGHT DIRECTIONAL -©Q l III ©© EDGE -LIT EXIT SIGN ARROWS. GREEN LETTERS WITH WHITE HOUSING. FURNISH WITH I io '� P WER/TELEPH NEIDATA 1 "A.F.F. ❑� E o 8 _ - RECEIVED R o FE.C. LRP -W -I -GC -LRA -120/277 -EL -N BRACKET FOR TOP RECESSED MOUNTING. FURNISH ALL NECESSARY MOUNTING HARDWARE AND HANGERS. WIRE TO EMERGENCY in CENTERLINE m = * RECEPTACLE CITY OF TUKWILA CIRCUIT AS SHOWN ON DRAWINGS. MAINT. FREE NI -CAD BATTERYco PACK AND TEST SWITCH. UL LISTED. FURNISHED BY TENANT, INSTALLED BY EC. r I `�� Co I iV� �� �. O� FINISH FLOOR FIRE ALARM PULL STATION 48"A.F.F. © JUN 2 8 �i3 . EQ EQ EQ EQ 6"1 12" WHERE UNDER FEC ONLY Z -1-A DUAL -LITE 1 LED (INCLUDED) 277 5 5 LOW PROFILE LED EXIT SIGN, SINGLE FACE WITH KNOCK OUT ' PERMIT CENTER LX -U -G -W -E DIRECTIONAL ARROWS, GREEN LETTERS WITH WHITE HOUSING. GLAZING TYP. FURNISH WITH BRACKET FOR RECESSED BACK MOUNTING. FURNISH ALL NECESSARY MOUNTING HARWARE AND HANGERS. WIRE TO CIRCUIT AS SHOWN ON PLANS. PROVIDE WITH -CAD @ COUNTERS 0EXTERIOR WINDOWS @ INTERIOR COLUMN @ TYPICAL DOOR MAINTENANCE FREE NI BATTERY. UL LISTED. FURNISHED BY TENANT, INSTALLED BY E.C. ` 0 63 ci ..�9 D. I EL 1EMERGENCY REFERENCE A0.03 .wAst� y MOUNTING HEIGHT LOCATIONS JotIiil 0 NOT TO SCALE i." H 0 ..irD,\ U- in LC E T r -i U -1 12 M co vii 2 N N CD 043 i C E i ® ":: o 0 aN V CJ Cn © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM m LZLJQ�� LLJ Z W W -I Z , i ZOQ LU C I- F -- - n 0 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS JA Drawn TG Checked TG Approved ELECTRICAL LEGEND, DETAILS, AND SCHEDULES Project No. 13007.00 Date PERMIT - 06.24.13 Last Revision E-1 . o [Z-1[ZZ] rEdir G5 _ (Typ) G5 G5 G5 G5 E1 G5 10 (TYP.)G5 SALES G5 { 2U{ A A A3 1161 A' 4 1 I 1 f 4 1A' 9 E f 1 A3 A I G5 16 1�1 \-11 - -�fI (TYP) G5 r AIM516 A3 G5v A4 I ASI I 1 I I4a 16 A.� A - A3 A 1. A _. --_I-...._._ 1995 Ell I A A A3 16 A4 -I t, 11 :3 G5 RD CAL: D1 3 2698 H1 CZ] [:11 [ZZ] LIZ] . Com] I I I K ELECTRIC ROOM VESTIBULE p. STOCK ROOM 2,335 SF • I D1E D Cal EMI REAK ROO , I D1 E (16) G9 FIXTURES \\ (35) G9 FIXTURES (18) G9 FIXTURES LIGHTING PLAN — SECOND FLOOR PLAN — PARTIAL SCALE: 1 /8"=1'-0" .1ENERAL ANAGER OS/GEN ENTRY VESTIBULE / M 15' C6D\ ■ 1$'-4" \ C6G C6� / \ / \ H1 9 ROOF BELOW LIGHTING PLAN — SECOND FLOOR PLAN SCALE: 1 /8"=1'-0" ELECTRICAL LIGHTING PLAN NOTES: LIGHTING PLAN — FIRST FLOOR PLAN — PARTIAL SCALE: 1 /8"=1'-0" ❑1 FOR INSTALLATION OF TYPE 'Al' & 'A4' FIXTURES, REFER TO 1/E-6.3. NOT USED 03 ALL TYPE 'G7' LIGHT FIXTURES SHALL BE ON SEPARATE CONTROLS TO MEET THE 2009 IECC DAYLIGHTING ZONE REQUIREMENTS. 17171 CONTRACTOR SHALL PROVIDE AND INSTALL OVERRIDE SWITCHES FOR ALL LIGHTING ZONES PER THE 'SMART CIRCUIT BREAKER SCHEDULE'. REFER TO CONTACTOR SCHEDULE ON SHEET E-6.1 FOR MORE INFORMATION AND COORDINATE ALL ELECTRICAL REQUIREMENTS WITH DIVCON'S 'KEITH SWEAT'(PHONE: 214-821-6958). 6 RECESSED JUNCTION BOXES CONTAINING THE WATTSTOPPER 'ELCU-200' DEVICE THAT CONTROL THE SWITCHED EMERGENCY LIGHTS POWERED BY CIRCUITS INV -1 & INV -3, CONTROLLED BY CIRCUIT H1-3 AND H1-5 AND INV -5 & INV -7, CONTROLLED BY CIRCUITS H1-7 AND H1-9. REFER TO WIRE DIAGRAM 1 ON SHEET E-6.2 FOR MORE INFORMATION. INSTALL REMOTE LOW VOLTAGE TRANSFORMER FOR 12V TRACK LIGHT FIXTURES AT WINDOWS AND LED LIGHTS ABOVE, REFER TO LIGHT FIXTURE SCHEDULE FOR SPECIFICATIONS. COORDINATE EXACT LOCATION WITH ARCHITECT. PROVIDE CONDUCTORS, SIZED FOR VOLTAGE DROP PER MANUFACTURER'S RECOMMENDATIONS, FROM REMOTE TRANSFORMER LOCATION TO LOW VOLTAGE TRACK. GANG TRANSFORMERS TOGETHER BEHIND ACCESS PANEL IN WALL BETWEEN BUMPER RAILS. COORDINATE EXACT LOCATION WITH TCS PROJECT MANAGER. Fl WATTSTOPPER ELCU-200 DEVICE LOCATION: CONTRACTOR SHALL CONNECT EXTERIOR LIGHT FIXTURES TO PANEL 'INV', CIRCUIT 6, VIA PHOTOCELL AND TO WATTSTOPPER 'ELCU-200' DEVICE, TO TURN THE FIXTURES 'ON' IN THE EVENT OF LOSS OF POWER WHEN THE PHOTOCELL HAS TURNED THE FIXTURES 'OFF'. REFER TO 1/E-6.2 FOR WIRING DIAGRAM. n 9 PROVIDE WALL MOUNTED PASSIVE INFRARED OCCUPANCY SENSOR FOR AUTOMATIC CONTROL OF ROOM LIGHT FIXTURES. OCCUPANCY SENSOR SHALL BE WATTSTOPPER MODEL NO. WS -200. REFER TO 2/E-6.2 FOR WIRING DIAGRAM. IINSTALL JUNCTION BOX DIRECTLY OVER FIXTURES. (JUNCTION BOXES SHOWN OFFSET FOR CLARITY). FOR INSTALLATION AND CIRCUITING FOR TYPE 'Al' EMEREGENCY FIXTURES, REFER TO 2/E-6.3) 10 MONO -POINT LIGHT FIXTURES MOUNTED TO GFRG COVES OR GWB CEILING. REFER TO 3/E-6.3 FOR ADDITIONAL INFORMATION. 11 NOT USED 12 MONO -POINT LIGHT FIXTURES MOUNTED TO UNISTRUT. REFER TO 4/E-6.3 FOR ADDITIONAL INFORMATION. 13 PROVIDE (1) JUNCTION BOX AT THE QUARTER POINTS OF THE SIGN LENGTH AT 9'-0" AFF TO CENTER OF JUNCTION BOX. PROVIDE (1) 20 AMP CIRCUIT AS SHOWN TO LOCATION SHOWN FOR FUTURE TENANT'S SIGNAGE. GC TO VERIFY EXACT LOCATION OF JUNCTION BOXES WITH TCS PROJECT MANAGER PRIOR TO INSTALLATION. GC TO COORDINATE INSTALLATION OF WIRING, AND CONDUIT WITH TENANT'S PROJECT MANAGER PRIOR TO ROUGH -IN. REFER TO SMART CIRCUIT BREAKER SCHEDULE ON SHEET E-6.1 FOR ADDITIONAL INFORMATION. PROVIDE DISCONNECT SWITCH WITHIN SIGHT OF TENANT'S SIGN. 14 PROVIDE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR FOR AUTOMATIC CONTROL OF ROOM LIGHT - FIXTURES. OCCUPANCY SENSOR SHALL BE WATTSTOPPER MODEL NO. WT -605. PROVIDE ALL LOW VOLTAGE WIRING BETWEEN OCCUPANCY SENSORS PER MANUFACTURER'S INSTRUCTIONS. REFER TO 3/E-6.2 FOR WIRE DIAGRAM. 15 PROVIDE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR FOR AUTOMATIC CONTROL OF RESTROOM LIGHT FIXTURES. OCCUPANCY SENSOR SHALL BE WATTSTOPPER MODEL NO. WT -605. PROVIDE ALL LOW VOLTAGE WIRING BETWEEN OCCUPANCY SENSORS PER MANUFACTURER'S INSTRUCTIONS. REFER TO 4/E-6.2 FOR WIRE DIAGRAM OF OCCUPANCY SENSOR AND RELAY CONNECTION TO EXHAUST FAN. .111 JUNCTION BOXES ON FASCIA NEAR END OF FIXTURES. REFER TO LIGHTING DETAILS ON SHEET 2/E-6.3. PROVIDE (3) WALL MTD. JUNCTION BOXES FOR (3) 50 1/2" X 50 1/2" BACK -LIT GRAPHIC DISPLAY NICHES & (1) 20" X 8' 10 1/2" PRODUCT SHELVES NICHES WITH (7) LOW VOLTAGE MR16 RECESSED LED DOWNLIGHTS. REFER TO ARCHITECTURAL ELEVATIONS FOR VERTICAL AND HORIZONTAL SPACING. 17 18 INSTALL REMOTE LOW VOLTAGE TRANSFORMER FOR BACK -LIT GRAPHIC DISPLAY PRODUCT SHELVES. LOCATED L.V. TRANSFORMERS IN 18"X18" ACCESS PANEL IN WALL BETWEEN BUMPER RAILS. REFER TO ARCHITECTURAL PLAN FOR ACCESS PANEL LOCATION. 19 20 21 22 PROVIDE (4) WALL MTD. JUNCTION BOXES FOR (4) 50 1/2" X 50 1/2" BACK -LIT GRAPHIC DISPLAY NICHES & (1) 20" X 8' 10 1/2" PRODUCT SHELVES NICHES WITH (7) LOW VOLTAGE MR16 RECESSED LED DOWNLIGHTS. REFER TO ARCHITECTURAL ELEVATIONS FOR VERTICAL AND HORIZONTAL SPACING. INSTALL REMOTE LOW VOLTAGE TRANSFORMER FOR BACK -LIT GRAPHIC DISPLAY PRODUCT SHELVES. LOCATED L.V. TRANSFORMERS ACCESSIBLE TO CEILING HATCH. PROVIDE (8) WALL MTD. JUNCTION BOXES FOR (6) LOW VOLTAGE MINI LED DOWNLIGHT CENTERED AT THE TOP OF ABOVE EACH NICHE ABOVE THE BACK -LIT GRAPHIC DISPLAYS. REFER TO ARCHITECTURAL ELEVATIONS FOR VERTICAL AND HORIZONTAL SPACING. INSTALL REMOTE LOW VOLTAGE TRANSFORMER FOR (6) LOW VOLTAGE MINI LED DOWNLIGHT CENTERED AT THE TOP OF ABOVE EACH NICHE ABOVE THE BACK -LIT GRAPHIC DISPLAYS. LOCATED L.V. TRANSFORMERS IN 18"X18" ACCESS PANEL IN WALL BETWEEN BUMPER RAILS. REFER TO ARCHITECTURAL PLAN FOR ACCESS PANEL LOCATION. ALL INTERIOR LIGHTING SHALL BE PROGRAMMED TO TURN 'ON' IN THE EVENT THE SECURITY SYSTEM ALARM IS ACTIVATED. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL REQUIREMENTS WITH DIVCONS. (TODD DEMPSEY AT 214-821-6958). REVIEWEDFORCOMPLIANCE WITH NFPA-70. NEC JUL 2 2 2013 City of I lj BUILDING DIVI 2-I:e N ELI -0631 REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING — NO WORK MAY START IN 'THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J—BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. RECEIVED CITY OF TUKWILA JUN 28 2013 PERMIT CENTER © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, D(75001 TEL 972 386 6888 Fax 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM H J F- J Z 00 W Q W Z O) O � � Q LLI wz U W <- 0 U —I ZH�� zOOF LLJ cf) (f)~ V) CO n 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS Drawn Checked Approved LIGHTING PLAN SECOND FLOOR Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E -2.O %1,,,,,_)" r d I, . 8959 Imo_' - ® -Aimminmsami ■ ELECTRICAL EMERGENCY LIGHTING GENERAL NOTES: III III MIN III I 6. CONTRACTOR TO SET ALL OCCUPANCY SENSORS AT MAXIMUM TIME—DELAY OF 30 MINUTES. 7. ALL EXIT SIGNS SHALL BE CONNECTED UNSWITCHED. E 11111 8. FOR LIGHTING CONTROLS OTHER THAN OCCUPANCY SENSOR, REFER TO SMART CIRCUIT BREAKER SCHEDULE AND PANELBOARD SCHEDULES ON SHEET E-6.1. 11111111111 1111 IMO MEN MIN 1. LIGHTING LOCATIONS SHOWN ON THIS SHEET ARE DIAGRAMMATIC ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATION, EXACT LOCATION, AND ADDITIONAL REQUIREMENTS. 2. ALL LIGHTING AND SIGNAGE CIRCUITS SHALL BE #10 AWG CONDUCTORS FOR HOME RUNS (INCLUDING NEUTRAL CONDUCTORS). 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. 4. CONCEAL ALL CONDUITS IN SALES AREA. 5. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT HEIGHTS AND LOCATIONS OF ALL LIGHTING NM =III I JUNCTION BOXES. CONTRACTOR TO VERIFY ALL JUNCTION BOX LOCATIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION. s, cy, et, • .4 .4 ,1 c., c., , .co ea 0 4.• 00 00 ELECTRICAL EMERGENCY LIGHTING PLAN NOTES: IINSTALL JUNCTION BOX DIRECTLY OVER FIXTURES. (JUNCTION BOXES SHOWN OFFSET FOR CLARITY). FOR INSTALLATION AND CIRCUITING FOR TYPE 'Al' EMEREGENCY FIXTURES, REFER TO 2/E-6.3) 2 3 4 5 6 SALES 7 FOR INSTALLATION OF NORMAL AND EMERGENCY TYPE 'Al' EMERGENCY FIXTURES, REFER TO 2/E-6.3. EMERGENCY LIGHTING/POWER INVERTER, DUAL VOLTAGE, FURNISHED BY OWNER AND INSTALLED BY GC. REFER TO SHEET E-6.1 FOR INVERTER PANEL SCHEDULE AND SHEET E-6.0 FOR ADDITIONAL INFORMATION. INTEGRATED FACILITY SYSTEM PROVIDED BY TENANT. REFER TO ONE—LINE DIAGRAM, 2/E-6.0, FOR ADDITIONAL INFORMATION. RECESSED JUNCTION BOXES CONTAINING THE WATTSTOPPER 'ELCU-200' DEVICE THAT CONTROL THE SWITCHED EMERGENCY LIGHTS POWERED BY CIRCUITS INV -1 & INV -3, CONTROLLED BY CIRCUIT HA -1 AND H1-3; INV -5 & INV -7, CONTROLLED BY CIRCUITS H1-9 AND H1-11; CIRCUIT INV -9 AND INV -11 AND CONTROLLED BY CIRCUITS H1-13. H1-15. REFER TO WIRE DIAGRAM 1 ON SHEET E-6.2 FOR MORE INFORMATION. ra © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM WATTSTOPPER ELCU-200 DEVICE LOCATION: CONTRACTOR SHALL CONNECT EXTERIOR LIGHT FIXTURES TO PANEL 'INV', CIRCUIT 6, VIA PHOTOCELL AND TO WATTSTOPPER 'ELCU-200' DEVICE, TO TURN THE FIXTURES 'ON' IN THE EVENT OF LOSS OF POWER WHEN THE PHOTOCELL HAS TURNED THE FIXTURES 'OFF'. REFER TO 1/E-6.2 FOR WIRING DIAGRAM. INSTALL JUNCTION BOXES ON FASCIA NEAR END OF FIXTURES. (JUNCTION BOXES SHOWN OFFSET FOR CLARITY). REFER TO LIGHTING DETAILS ON SHEET 2/E-6.3 A Ran D1 E 11111111 BED IEBEI 13113:1 131E1 REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. U) Z 1— CO REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. DN . MALL STORAGE " REFER TO SHEET 1 /E6.2 FOR CONTROL OF EMERGENCY AND NORMAL BRANCH TYPE 'A' LIGHT FIXTURES. WOMEN TERRACE Cal Ti 1 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC -JUL 2 2 2013 / o O • City of Tukwila BUILDING DIVISION ROOF BELOW RECEIVED CITY OF TUKWILA JUN 2 8 2013 EL t3. 01937 PERMIT CENTER 'EMERGENCY' LIGHTING — SECOND F PLAN No. Date Item Drawn Checked Approved REVISIONS 'EMERGENCY' LIGHTING SECOND FLOOR PLAN Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E-2. 1 FLA Pbn co c CD m co '-5 1/2" 3/8" co a 8 m —. aliammui. 8, L_______Iiiiimr, ifilimmiv8- r'iiiir 1/4" Receplac, Recepfac! • MOUNT DATA J -BOX ON 1 '-0" GWB CEILING MOUNT DATA J -BOX ON • . .. ........... TERRACE. REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. GENERAL ELECTRICAL NOTES: 1. ALL LOW VOLTAGE WIRING SHALL BE ROUTED IN CONDUIT UNLESS CONCEALED WITHIN WALLS, ABOVE HARD CEILINGS, WITHIN EQUIPMENT ROOMS. ALL LOW VOLTAGE CABLE NOT INSTALLED IN CONDUIT SHALL BE PLENUM -RATED. 2. COORDINATE THE LOCATION AND ELEVATION OF WALL -MOUNTED DEVICES WITH PRESENTATION BOARDS, DISPLAY CABINETS, SHELVES OR OTHER COMPONENTS SHOWN ON THE ARCHITECTURAL DRAWINGS THAT ARE TO BE INSTALLED UNDER OTHER DIVISIONS. CONTRACTOR WILL NOT BE REIMBURSED FOR RELOCATION OF WALL -MOUNTED DEVICES CAUSED BY A LACK OF COORDINATION. 3. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION ON DATA CABLING AND DEVICES. ELECTRICAL PLAN NOTES: n 4 5 7 8 9 10 11 MOUNT RECEPTACLE AT CEILING/STRUCTURE ABOVE DISPLAY WINDOW. COORDINATE LOCATION WITH ARCHITECTURAL DETAILS. RECEPTACLES SHALL BE CENTERED ON AND IN BETWEEN LIGHT FIXTURES. PROVIDE (1) CAT 6 LINE FROM SERVER RACK IN COMMUNICATIONS ROOM TO LOCATION SHOWN FOR WIRELESS ANTENNA. USE PLENUM RATED CABLE - REFER TO DETAIL 6/E6.3. REFER TO DIVISION 26000 FOR ADDITIONAL INFORMATION. CONFIRM EXACT LOCATION WITH TCS PROJECT MANAGE PRIOR TO ROUGH -IN. CONTRACTOR SHALL MOUNT JUNCTION BOX AT 15'-0" AFF VIA RIGID CONDUIT AS REQUIRED. SAME AS NOTE #2, EXCEPT RECESSED JUNCTION BOX IN GWB CEILING. REFER TO 3/E3.0 & 1/E1.0 FOR MOUNTING HEIGHTS OF DUPLEX RECEPTACLE BELOW FIRE EXTINGUISHER CABINET. REFER TO 2/E3.0 & 1/E1.0, THIS SHEET AND FOR MOUNTING HEIGHTS OF COMBINATION TEMPERATURE AND HUMIDITY SENSOR. MOUNT DATA JACK IN CASHWRAP FOR THE INDYME ANTENNA (ANTENNA PORTION EXPOSED). LABEL IN COMMUNICATION ROOM. CARD READER; REFER TO BAS DRAWINGS FOR ADDITIONAL INFORMATION AND EXACT LOCATION. PROVIDE 3/4" CONDUIT AND PULL STRING FROM DOOR CONTACT LOCATION TO SECURITY MONITORING EQUIPMENT. ROUTE ABOVE FINISHED CEILING OR VIA WIREWAY. REFER TO BAS DRAWINGS FOR SECURITY MONITORING EQUIPMENT LOCATION. PROVIDE LOW VOLTAGE TRANSFORMER FOR PANIC DEVICE MOUNTED ABOVE THE CEILING BEHIND ACCESS PANEL. CONTRACTOR SHALL PROVIDE JUNCTION BOX AND PLENUM RATED, LOW VOLTAGE WIRE TO POWER ACTUATOR FOR FIRE/SMOKE DAMPERS. COORDINATE ALL ELECTRICAL REQUIREMENTS WITH FIRE CONTRACTOR PRIOR TO ROUGH -IN. PEOPLE COUNTER MOUNTED AT CEILING CENTERED BETWEEN LIGHTS - GC TO PROVIDE AND INSTALL ONE CAT 6 CABLE STUBBED UP 6" BELOW CEILING THROUGH A 3/4" DIA. GROMMETED HOLE (NO BACK BOX OR FACEPLATE REQUIRED) TERMINATE END OF CABLE WITH A SYSTEMAX MALE CONNECTOR. REFER TO DIVISION 25 FOR PART NUMBER TAG CABLE 4" FROM END CABLE TO RUN BACK TO SERVER IN COMMUNICATIONS ROOM #107. • ESCALATORS r. • • ELEVATOR MACHINE ROOM MUNI NIMBI MINIM BOTTOM OF CLG REFER TO ARCH S PLAN ROOF BELOW 1 IMMUNE 15 PARTIAL FIRST FLOOR — POWER PLAN COMBINATION TEMPERATURE AND HUMIDITY SENSOR (TYP.) co WALL ELEVATION WALL AND COLUMN MOUNTED DETAIL NOT TO SCALE RECEPTACLE 12" WHERE UNDER FEC ENT REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC I ma --City of Tukwila BUILDING DIVISION F.E.C. FINISH FLOOR WALL ELEVATION ALL DEVICES TO ALIGN VERTICALLY- TYP. ALL LOCATIONS. RECEIVED CITY OF TUKWILA JUN 2 8 202 PERMIT CENTER FEC CAB. DUPLEX RECEPT. 8c PHONE RECEPT MT NOT TO SCALE 41) co U. sla Um ma 0 0 CD CV as oo oo LCS Ca © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TI -1 RL TG BT BM Txj LLJ Z No. Date Item REVISIONS Drawn Checked TG Approved FIRST & SECOND TG FLOOR POWER PLANS EI.A#4q) 6361 SECOND FLOOR — POWER PLAN Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E -3.D #11 — SURFACE MOUNT TO 12' SOFFIT CEILING; CENTER ON REGISTER LIGHTS ................. SECURITY GENERAL NOTES: CAMERA SYSTEM CABLE IS NOT REQUIRED TO BE RUN IN CONDUIT IF PLENUM RATED CABLE IS USED AS SPECIFIED BELOW. WIRING MUST BE RUN CONCEALED WITH—IN WALLS AND ABOVE CEILINGS OR TIED TO THE BUILDING ROOF STRUCTURE IN THE STOCKROOM. 2. ALL CABLE TO BE PLENUM RATED. 3. ALL DEVICES SHALL BE WHITE. 4. REFER TO SHEETS E-5.1, E-5.2, E-7.0 AND E-8.0 FOR DEVICE LOCATIONS IN OFFICES. 5. G.C. TO COORDINATE LOCATION OF CAMERA HEAD END EQUIPMENT WITH TCS PROJECT MANAGER & ADT REP. PRIOR TO ROUGH—IN. 6. REFER TO 4/E-6.3 FOR TYPICAL CAMERA INSTALLATION. 7. REFER TO ADT'S CAMERA PLAN, SHEET CAM 1.10, FOR CAMERA MOUNTING INFORMATION. SECURITY KEYED NOTES: 0 ELECTRICAL CONTRACTOR SHALL RUN (1) CAT -6 DATA LINE FROM THE SERVER RACK IN THE COMMUNICATIONS ROOM TO EACH CAMERA LOCATION. PROVIDE PATHWAY OR USE PLENUM RATED CABLE. ELECTRICAL CONTRACTOR SHALL PROVIDE (1) SYSTEMAX PART #107984015 ABOVE CEILING AT EACH CAMERA LOCATION + (1) 6'-0" LONG WHITE PATCH CORD AT EACH CAMERA LOCATION AND A 3/4" DIA. HOLE IN GYP. CEILING WITH GROMMET. EXTEND CABLE THROUGH HOLE 4" TERMINATE CABLE WITH A SYSTEMAX MALE CONNECTOR PER DIVISION 26 AND INSTALL CABLE LABEL 4" ABOVE TERMINATION POINT. PROVIDE (1) CAT -6 DATA LINE FROM THE SERVER TO THE CAMERA RACK IN THE GENERAL MANAGER'S OFFICE. REFER TO DETAIL 5, SHEET E6.3 FOR MORE INFORMATION. O2 ELECTRICAL CONTRACTOR SHALL RUN (1) CAT -6 DATA LINE FROM THE SERVER RACK IN THE COMMUNICATIONS ROOM TO EACH CAMERA LOCATION. PROVIDE PATHWAY OR USE PLENUM RATED CABLE. ELECTRICAL CONTRACTOR SHALL PROVIDE 3/4" RIGID CONDUIT AND JUNCTION BOX MOUNTED AT 14'-0" IN GYP. CEILING WITH GROMMET AND EXTEND CABLE THROUGH HOLE 4" AND TERMINATE CABLE WITH A SYSTEMAX MALE CONNECTOR PER DIVISION 26 AND INSTALL CABLE LABEL 4" ABOVE TERMINATION POINT. PROVIDE (1) CAT -6 DATA LINE FROM THE SERVER TO THE CAMERA RACK IN THE GENERAL MANAGER'S OFFICE. REFER TO DETAIL 5, SHEET E6.3 FOR MORE INFORMATION. O ELECTRICAL CONTRACTOR SHALL RUN (1) CAT -6 DATA LINE FROM THE SERVER RACK IN THE COMMUNICATIONS ROOM TO EACH JAMB CAMERA LOCATION. JAMB CAMERAS ARE LOCATED ON THE INTERIOR SIDE OF SLIDING DOORS AT 54" AFF — JAMB CAMERAS COME FACTORY INSTALLED, THE ELECTRICAL CONTRACTOR SHALL CONNECT TO CAT 6 CABLE AT TIME OF DOOR INTSALLATION. SECURITY CAMERA LEGEND ■ 0 Lim 0 izo 0 0 2808 Fairmount Street N t\ N vi cv Ca © Good Fulton & Farrell 2006 FIXED CAMERA IN DOME OPTZ 360 IN DOME GC TO COORDINATE LOCATION OF CAMERA HEAD END WITH TENANT PROJECT MANAGER & ADT REPRESENTATIVE PRIOR TO ROUGH—IN. HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ROUGH—IN, CONDUIT, AND J—BOX SCOPE OF WORK. REFER TO ELECTRICAL DWGS E7 & E8 FOR DEVICE LOCATIONS IN OFFICES. ALL DEVICES ARE TO BE WHITE TH RL TG BT BM CAMERA SYSTEM CABLE IS NOT REQUIRED TO BE RUN IN CONDUIT IF PLENUM RATED CABLE IS USED AS SPECIFIED BELOW. WIRING MUST BE RUN CONCEALED WITHIN WALLS AND ABOVE CEILINGS OR TIED TO THE BUILDING ROOF STRUCTURE IN THE STOCK ROOM. ALL CABLE USED TO BE PLENUM RATED ALL LIGHTING SHALL BE PROGRAMMED TO TURN 'ON' IN THE EVENT THE SECURITY SYSTEM ALARM IS ACTIVATED. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL REQUIREMENTS WITH DIVCONS. (TODD DEMPSEY AT 214-821-6958). LAN.DLC •ELECTR RO I REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. #30 — SURFAOE MOUNT TO CEILING 3'-1" # 9 — SURFACE MOUNT 2-11" Ti CEILING LIGHTING..AND MALL ST.ORAG.E. . REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. #32—SURFACE MOUNT TO CEILING, IN FRONT OF • TERRACE... #7— (ANALOG) RUN WIRE TO STANLEY DOOR FOR JA B CAM .............................. n 0 0 0 0 0 0 0 0 0 0 0 0 #33—SURFACE MOUNT TO CEILING, NEAR WALL, IN LINE WITH FRONT EDGE OF MONEY .. .......................... .........• ........... !REVIEWED Fes; a�f �i�sA�CFE. vvi-TH 71 PA 70 - MEC No. Date Item JUL 2 2 2013 REVISIONS TG Drawn ..................... TG Checked RECEIVED CITY OF TUKWIL TG Approved #12—(IP FIXED JCAMEitA) — MOUNT TO TOP HORIZONTAL VESTIBULE MULLION FACING THE REGISTER BAY; SHOULD SEE UNDER LIGHTING; INLINE WITH THE BACKSIDE OF THE REGISTER DRAWER JUN 28 2013 PERMIT CENTER 2— RUN WIRE TO STANLEY OOR FOR JAMB CAM SECURITY CAMERA SECOND FLOOR ELI --o 63q SECOND FLOOR - SECURITY CAMERA PLAN SCALE: 1 /8"=1'-0" Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E-3. 1 Salts Floor - West Ill minance (Fc) Ave age = 4.07 Max'mum = 11.1 Min'mum = 0.3 Avg Min Ratio = 13.57 Max Min Ratio = 37.00 Illuminance (Fc) Average = 3.40 Maximum = 8.9 Minimum = 1.5 Avg/Min Ratio Max/Min Ratio •.0 1.7 t, 595 - t-8 5.9 to 5 5.0 5.: C5.5 1 5.e to.l 50.8 to 1 5.2 t.3 to 1.55 to to to 5.7 t.3 5.4 Sales Floo - East Illuminant (Fc) Average = .57 Maximum = .0 Minimum = .3 Avg/Min Ra io = 11.90 Max/Min Ra io = 26.67 5 6 43.9 43.9 t3 t.l t to 5.3 1 5.a S -a 5.7 to 5 a 5.9 5.0 to t.l 1.94 to 5.6 5.1 to 1.5 5.3 5.0 to to to 5.1 5.7 5.3 i.2 to S.o 0E1 0 ®E to to t.. 1.1 5.89 t5 ti. 1.6 3.4 S.3 S.4 1.9 t2 t7 5.3 5.8 to to k.5 to 5.0 to 5.6 to S . 1 t , 5 5.e 5.8 5.9 S 5.4 t.2 5.9 S.6 ,.o t.o 5.3 4.0 5.0 5.0 5._ -.7 5.1 t.2 1.9 1.3 et., 5.o /.4 11.3 1., to to to 5, 50 57 S.4 5.3 1.6 1.2 5.00 5.6 5., 5.5 1 1.9 5-o 5.6 1.3 5.6 5.5 5.5 5.6 5.9 1.2 1.9 5.7 to to 000 t9 t.o 5.5 S., 5 1.] to dS 1.3 t0 5 5.5 5 1.00 t.l to t.3 5.3 to 5.9 S.e 5.8 5 BCS 5.6 3.3 3 4 t.6 5.1 5.1 1.1r;y15.2 t.3 1.9 1.0 5.1 1.5 1.2 1.0 5.9 5.z 5. 5.5 1.3 1.e S., 5 •1.3 to to S. t6 1.2 S 5.2 5.00 11?. to t.pjt.9 5.0 5.2 5.7 5.0 e.e• *se 5.4 to 3.2 S. 1.o 1.8 1.o 5., 5.2 5.5 5, 5.4 5.1 5.2 S.F 5.2 5 5.83.2 $.6 /.o 61 t0 5.7 to 5.0 .0 t.a 5 - t9 5.4 5.3 5.6 0 ., to to to .4 M.2 5.0 .3 •e, 1.1 t.o 5.1 5.1 t.2 1.7 1.2 to •a S.3 S. t.3 5, 5.8 5.3 .1 t.- 5 t.o t.o to to 8 g 5.3 1.3 3.9 to 5.9 5., 5.9 5.1 5. 5.6 3.5 3.1 Sd to 5.5 S.o S.e73 5.6 5.662 3.e 5. 5.7 1.5 to /.6 to to 5-9 - 1��M GSA 5 S-11 5 S.a 5 ` 5.: 5.00 ,.1 t.o 5.1 �_ . S : S.4 S., 5. 5.3 t, t.6 to .e. 5.5 5.3 S. 5.4 S.1 5.6 5.1 to 5.o to 5.6 5.P to S.o 3., 5.1 S. to t.2 to 5.1 .6 59 5 5 5.0 1.9 �.o a 84 DA 84 ea 5.1 5.4 1 t3 5.7 5.1 1.5 5.00 to 5.3 5.1 5.9 t4 to :.•1 S., 5 5.6 5. 5.5 51 5.1 5.n :.:°::: ..5 5.8t.21t9100 55, 5.Ss S. 5.1 5.7.3 t.l 5.3 5.2 1, 5.9 5.6 5.3 5.: to 5.E 3.5_ 5.2 .o 5.1 51 5.7 to 1.0 S.o 5.9 5.8 3.1 5, M.2 S.2 1 5 3.1 1., 2.9 5., 3 01.3 1.4 5.3 1.2 1.0 1.0 1.0 1.1 5.2 5., 1.8 5.5 3.3 to to S 1 5.1 to to t. Al 1.n 1.4 L 0 ®5.7 5.o t, 5. 5.3 to S. 3.4 5.o 5.3 • 3 ''• , 6 2 5.2 to 5.2 5.8 5.7 t00 to to 3.4 5.9 '' t.3 5.7 5.6 t.3 5.6 5.7 1.0 1.5. 5.2 1.R 80 /.4 S9 .0 5.4 1., 1.9 5.6 5.o .2 Y.2 t6 5-00 1.2 to t.5 1.9 to t E r to .4 5.8 to 5.0 l.0 5.1 5.5 C5.1 5.5 to 5.5 to so.o 3.6 3.6 d 73 c 5.n 5.5 5.6 5.8 5.o t9 to 5.3 5.7 5.0 .1 1.8 3 5.5 1.3 11.6 5.7 5 5.6 to k\!..01.6 5.3 . to to 5.6 S. 5.7 5.5 S.9 5.: 5.2 5.2 5.6 5.8 5.2 5., 5.9 1.1 1.2 5.3 5.$ 5., S.o 5.0 ..9 5.0 S. OF.'00 :511 • 5..,. 5.00 5.3 5.3 a. 5.0 43.8 1., to 5.9 5.8 w412 1 • 3 5.o 5.5 10.7 1[.6 S.8 1.5 1.1 1.E 13.5 cd.o 1.6 5 13.1.5 5.1 1 ' 1.3 1.3._ _ 5.7 t.4 1.. 5.1 1.2 S 8 2 $ 4 73 • _..0 �. 1.2 1.2 1.1 to tP to to 59 1, 1, 1, •„ 5, 40 4,. 5 5Ll5, 57 t1 ea 5.3 1.3 _ 5.1 5.1 !.o 5.1 19 1.11 Lois :. • , • , • . • . • • ., • , • .. 4 , 4 , 4 . 4 - 4 . • , 4 . 5 - S.3 5. 5.2 S., •9 5. 5 5 5 R.5 So 5 1 •-o ., S.- S. •. o •.7 S l 5.6 S.o 5.' 5.2 &5.5 5., 1 2 2 $ 2 $ 0 0 1 1 5- 5, ° 5 5= 5 0 I 5.1 uo S t, 5. 5.3 to S. 3.4 5.o 5.3 • 3 ''• , 6 2 5.2 to 5.2 5.8 5.7 t00 to to 3.4 5.9 '' t.3 5.7 5.6 t.3 5.6 5.7 1.0 1.5. 5.2 1.R 80 /.4 S9 .0 5.4 1., 1.9 5.6 5.o .2 Y.2 t6 5-00 1.2 to t.5 1.9 to t E r to .4 5.8 to 5.0 l.0 5.1 5.5 C5.1 5.5 to 5.5 to so.o 3.6 3.6 d 73 c 5.n 5.5 5.6 5.8 5.o t9 to 5.3 5.7 5.0 .1 1.8 3 5.5 1.3 11.6 5.7 5 5.6 to k\!..01.6 5.3 . to to 5.6 S. 5.7 5.5 S.9 5.: 5.2 5.2 5.6 5.8 5.2 5., 5.9 1.1 1.2 5.3 5.$ 5., S.o 5.0 ..9 5.0 S. OF.'00 :511 • 5..,. 5.00 5.3 5.3 a. 5.0 43.8 1., to 5.9 5.8 w412 1 • 3 5.o 5.5 10.7 1[.6 S.8 1.5 1.1 1.E 13.5 cd.o 1.6 5 13.1.5 5.1 1 ' 1.3 1.3._ _ 5.7 t.4 1.. 5.1 1.2 S 8 2 $ 4 73 • _..0 �. 1.2 1.2 1.1 to tP to to 59 1, 1, 1, •„ 5, 40 4,. 5 5Ll5, 57 t1 ea 5.3 1.3 _ 5.1 5.1 !.o 5.1 19 1.11 Lois :. • , • , • . • . • • ., • , • .. 4 , 4 , 4 . 4 - 4 . • , 4 . 5 - S.3 5. 5.2 S., •9 5. 5 5 5 R.5 So 5 1 •-o ., S.- S. •. o •.7 S l 5.6 S.o 5.' 5.2 &5.5 5., 1 2 2 $ 2 $ 0 0 1 1 5- 5, ° 5 5= 5 0 I 5.1 5.3 5.2 "0.0 7.6 "'.7 1 5 1.0 0.9 5.0 0.00 4'0..1 '0.0 1."5'.. 0.3 0.5 0.9 1.2 5.1 5.9 5.5 5.0 1., 1.0 5.9 5.9 to 110 ._ 5.0 t2 5.3 5.0 .7 M.a to .6 to 5.3 1 ^ £f6 1.9 .0 1.5 5.4 ADJACENT TENANT 5.3 I S., to 1. S.0 5.3 5.1 5, 5.B 5.E S., 5.5 5.2 5.3. to 5., to 5.9 59 1.2 5.5 to .o 5.4 5 •0 S . I •.E I 5.5 5.1 5. 3.6 3.2 S.4 S.o 5.9 5 'o t.e 4�R 5.5 • - to 1.0 5.2 • , 5.0 8 _ 5.: 1.0 �' - 5.7 5.3 5.1 5.2 1.0 1.2 1_0 5.6 5.e 5 7 5.5 5.3 5.9 5.6 Oa 5.5 1.0 5.0 1.0 0.1 5.0 S.9 - , 00 _, S - _ 1 1.1 1.5 1., 5.1 t.1 t.e 5.4 S.i t.s 'P 5.7 5., E.5 t.5 t., to to 5.7 5., 1.9 1.9 1.1 5.0 5.7 5.7 5., 5.00 1.3 •5.1 5.9 3.9 3.6 5.3 1.1 1.oJ5.1 5.0 5., 5.5 5.E 5.B S.o Ji 3.2 3.1 1.3 5.7 5.3 i.5 5.5 5., 5.7 1.0 5., 5-' S._- l.o .6 5.2 5.1 1.F i.' S9 5.8 5.8 5.o 1.5 5, 1.5 S.o 3-5 .1 S. 5 S. 5. 1.2 S.o S., S.1 3.4 S.o 5.000 5.E 5.o 5.F 5.773 5.5 5.55 1.0 5.56 5.0 S. S.B : S.o 5 ] 1.8 5.z S.2 ce oe _ a o o'• 8 oe 1.6 1.5 f.7 5.5 1.5 S. 5.6 1.9 S.o 3.1 e.e 5.3 1 �h.E S.o 5.1 S 1.6 .l.e 5.o 1.0 31.5 52 S.o 735.2 51 5.6 35.55 34 5.1 733.00 595 E 85., S. S. 5.0 S.z 5.0 8 g 73 2 • 5 5.5 o-2 1.7 1.2 5.7 5.9_ S. 5.4 5.4 5.5 15.7 1.1 1.6 5.5 3.8 t.1 500 AtI.P 5.5 t.5 1.P I- i `1q•qgy 000 1.- L4 1.5 1., 5.2 S.' 1.6 S.o S.o 1. 3.1 1.5 3.7 5.- 5.0 1.00 1 3 5.3 5.55 5.4 t.0 t.- S.: S. S.6 ^ 4 La 1.8 1.5 1.9 1.55 ^_.: -'.1 1.3 •.3 •.2 c .9 1.,1 1.0 5.7 5.00 5._ 5.1 5.E 15.7 9n is .0 S.o S.4 5.4 5.1 5.7 S.7 1.1 1.1 1.2 5.5 5.4 5.E 5.2 3.2 3.7 5.4 S.s 5.7 S.o 5 4 1.4 3.9 5.7 3.3 ! S. 5.8 5.173' 5.6 S.* S.4 S. 5.6 5.2 5.6 5.- 5.9 5.84 5.9 5.773' 5.6 5.1 5.1 .0 1.0 5 t.4 5.2 t.ol 5 1._ 1._ 1.11 1., 1., 1... 1.. 1.. 1 a •.o 1.9 .6 1.4 1 1.0 1.a 1.: 1.1 1.: 1.4 1.5 S.4 SSf�.a • F • , • : 4 0 5.5 5.9 5.6 1., •/ __ 3.7 �'S�- � f • 4 • .1 S _ 5 ,1 5.3 !✓� 5.3 5.3 it 5, 1.] �.o 1.= 5.55 .5.0' T. 5 5.52 003.1 a t1i Io .o S.aR 3.5 9 1.0 1.0 5.7 5.85.3 5.4 5.2 5.0 5.3 5 5 5.0 5.0 5.1 1.7 t. 5.5 5.5 5.6 S.z • 4 5.5. S. • . 5.1i 5.0 5.6 5.4 5.9 5.4 5.5 5.1 S.0 1.9 5.6 5., 1.9 5.4 5.1 1.5 5., 5.5 • ] 1.' S., 5.,1 5.. ._ 5.7 5.3 5.00 3., S.o 1.4 04 1 0 . a7 1 i_. 5.00 5.1 -'=5., 1.8 5-, 3.3 5.E 5.8 to `519 5.7 5.5 5.4 5.E •73. 5.5 5., S.7 5.9 5.7 5.6 5.9 • , • 1 5.1 S.3 5., 5.5 5.4 S.: 5.1 5.0 5.9 .. 1.8 1.9 1.31 5.9 �.o to 5.0 5� t 5 ! q t 4 5.1 1.6 .0 5 1.6 9 oo 1.00 5.0 5.6 5.5 1.5 5.4 5.7 5.9 t.0 S. 5 6 S -E S.o 5., 5.4 Sa 5.1 5.3 9 2 a g $ g $ 1., S.e X .0 1.o 5.4 5.0 S.7 5.5 S.a 5.3 5.7 .9 5., 5.1 t.5 5.2 ._ 5.E 3.5 5., 1.4 5, 5.7 5.4 5.6 5.6 5.: S.o 5.7 5.3 5.1 5.0 1.5 '.0 5.: 5.s 1.6 tto S.4 S. o 14.5 5735 t.1 t.6 D8 S.o •736 1.3 0 9 2 Sea 5.7 5.00 S.6 5.2 5., S. 5.3 Bpi.. 5.1 5.5 S. 3.5 S.,, 1.4 1.00 /.8 5.Q 5.6 5. 5, S., 5.a 5. 5.2 5.0 5.0 '.2 5.5 5., 5.0 5.4 5.0 5.0 1.5 S.,s 5.\1 1.3 t.4 5.3 5.1 .6 t.l t.l S.1 1.2 ea - ® ® S.o •.9 4 q • , • , •. , 4 5 • 5 3.4 5.2 S.0 S o *1 o °i` 3 4 7 •3.6 5.7 5.0 5.3 5.' 3-, 5.6 S.2 t.i 5., S.5 1.1 1.1 1.2 .� .t1.E 5.2 1.00 2 S.R 1_'31.1 S. 5.E 3.9 1� 5.5 1.0 3.5 _ 5.6 5.,1 _ .3 F SALES e 0 $� 0 °e 1., 1.0 S.a _.e 4 7 5.0 5.9 3.6 1.5 5.9 1.9 S 3 1.3 l.E 5.6 1.5 5 0 • 4 73 c $ 5 1.P l.o H 3.3 5., S., 5.9 t.1 Et.3 5.0 .6 1.61` ..e 5.1 .4 S.E 5.E 1.6 S.1 • S Q 9 Q g 8 g Q 2 4 5., 5., 5.0 5.s 5.9 S.1 S.o • e 5f26. 5.5 3.6 5.7 5., 5.3 1.9 5 s 1.4 1.B 5.4 5.5 S. 3.3 5.a 1.6 1.8 c.2 3.6 5.0 5., 5.9 5.1 t.3 1.3 S.3 S.0 5.7 5-, 1.8 1.1 • - • c S., 5.4 5 S.0 5., 500 • 4 S -•.5.6 5 5 4.3 5.1 • 2 5 , R_5 5.'1 5.4 / - 5.1 •1.- i.5 ).l 5.4 S,, 5.' �.. 1.52 t.l '.i ° 5.02 5, Fe ,2 t, 1, 47°1 5.2 •., S. 1.3 5.1 5. 5.o 5.8 5.E 5.E 5.E 5., 5.00 5.4 5.2 5.3 5.4 5.6 5.6 5.00 S.: 1.9 1.8 5, 0.0 5.: 5.9 S., 5.E 1.1 t., 5.1 5., 5./ 1.E t.l 5, 5., z 1., 5.8 5.2 1.2 M 5 2 1.0 5.7 5.4 S.x 11.4 59 5.4 S.: 5.3 56 1.2 Lo 5.e 5., 5 , 5.e 1.1 1.4 1.9 2. 500 5.z 1.5( 1n .0 S.1 5., 5.4i 5.2 �.o t., RS R� S.o t.E 5._= .3 5.E S 5.2 5.o 3.5. B/}3 1.3 1.5 .555 5.5 1.1 5.E 3.4 .1 •o 1.5 1.1 S.o S.7 4.6 0 6 t S. 5.0 S.e 5., 5.4 S Q 2 73 4 $ 1.E 1.l a 5.0 5., 1.5 5. S. 5.00 5.] 1.0 1.2 5., 5.6 5.,1 5.0 5.3 t., 5.5 1.2 5.1 1.2 I 1, 5.2 5.5 .4 5..0 5.7 5 3.1 •.o 5.' 5., • 2 �.5 3 5.1 1-5 1 5.8 1.9 5-i _,1 S.e 1.00 1 1., 1.8 _ 5.2 S9 3-,1 1�,5 5.2 5.6 5�3 5.5 5.00 5.6 5.4 t a ♦p.'o t.0 5., 5.6 5.6 1.1 1 QU 73 al, O 9 O O 5 Q 9 9 9 00 3.3 3.0 3.1 ._ I I 3.7 S.o 5. 3.7 5.3 5.9 5.7 S. 5.00 •+.e 5.473 5.6 5.64 5.E 3.373 5.1 19 1.9 0.l 5..1 3.3 5.1 5,, S.o 5.3 5.2 5-, �t.z 5.1 5.4 5.3 1.9 1.3 5.9 5.5 •.2 1.9 ._ ..9 ., ., ..e a ..9 .1 .- 9 ;,>t -- 1.5 1.00 5. S.o 1.4 iii 1.7 1.00 ,.l 5.00 1.4 1, t.2 39 t.9 5.1 5.9 L.7 =-=t1 5.6 5.3 5.0 5.0 E 4 L� 1 2 73 8 S 1.6 5.0 .1 5.6 1.5 1.7 5.7 5.4 1_:°4-.--,--" Q - -"-----5.7'-)D5.7 b.F .2 5.6 5.0 ee 1.6 5.3 S.o • 1 IW.0 to o9 S.E 11.4 5., 5.0 S 2 1. 5005.2 5.E 1.a ..0 5.4 5.0 5.6 5., 5.8 5.2 1.E 5.1 5.00 S.e t.0 1.3 5.0 t.9 '0.0 o., L., L.0 5 S.0 5.9 5.7 5. 1.B 1.4 S.A 5.9 5.9 5.9 •_.° 5.5 5.9 S.4 S.9 •., 5.9 5.5 5.6 1.9 1.o S.a r ..0 5.2 5.9 1.1 'F.3 5.673 5., 1.o 5.^ 5.5 $'.5 3.84 3.9 .6 1.94 1.1 7.o 5.7 5.0 1 5 S.o 5.1 5 3 to 5.0 5- S.'1 5.1 _.. __ __ _._ _. _._ _. _. _._ _._ _._ e 1., 1.00 .0 1.9 5.0 _.1 5., 5.1 5.2 1.9 1.8 11.6 5.1 5.3 5.4 5.o 1.6 1.1 5.9 5.00 5.5 55.7 b ' 0 0 9 5.5 S.a�1.2 t.0 --_ E �.1 3 1 - •l.o 1.3 5.1 • 5.0 5., 1.6 1.7 8i .9 1.0 S 3 i.6 01' 1.0 rr�e 5.6 5.1 1.5 5.3 t.=_ 5.1 1.E 5.5 3.4 S. 1.E 1.1 5.e 5.6 3.00 to 5.6 5., 5.5 1.4 42.0 �. 1.00 5,, l 1.6 59 ..0 5.3 5 2 i.o 5.1 S. 4.93 17.00 17.78 1 .49 16.14 5 LANOL RD ELECTR CAL ROOM MIN 5.0 5.s .0 5.5 5.] 113.. 3.4 5.2 5.9 5.6 5.9 5.7 5. S.3 5.9 S.2 5.9 5.5 5.2 5., 5.9 5.0 5.5 5.0 r.4 5.e 1.E 5.2 S.o 5.1 5.0 5.4 1.7 5.3 5.2 5.4 1.8 5.7 S., 1.0 5.7 4.9 5.7 S.., 5 3 1.5 p q p A • Epp.8��715.2: 19.851 .6118.131 S.1 5.5 5.7 5.: 5.5 5. 1.00 1.2 5 _ 1.6 1.9 1.3 5.9 5.6 1► •Y .4 5.6 l.5 to '1.3 1.3 7.5 5.s 09 1.0 45, Bo .o 5.0 Io 5.1 5.1 A 5 L F } 8.10 110.41 555.92 19.4, 1 S.3 51 5 7 5.2 59 5, 5.6 5 59 10 53 SE •, 5. 5.4 tE 5. t.a`=1ta t.4 1P ta 5.1 S1 Q S g $ 5.5 1.900 .3 5.e 1.7 5.1 5.5 3.8 S. 5.0 1.6 1.2 1.1 1.4 1.a 5.8 .B 5.5 5.6 5.5 5.4 S.o 1.9 1.4 i.. ( 1 i 8.54 50.61 95 .06 19.6E 51 • , 1.9 0.o 1.1 5.9 5.7 5.0 5.E 5.9 l.0 5.3 5., 5.4 S.3 5.6 5.0 5 5.5 5.0 1.9 5.6 5- 1.4 5.6 1.6 1.a �.0 • - 5 , .8 55..1 1. 0... -- �y E.]] 19.R2 0.65 5 .45 418.98 1 Be L w - 5.7 5.9 5.3 5.3 5.3 5.0 1. 5.6 S.o S.22 3.5 5.}, 5.s S. 5.1 S. 5.6 5 5.5 5_ S. 5.3 3.2 5.5 5.9 0.0 5.0 5 : .1 S.E 5.3� V - g - g� - 2.58 16.23 18.3819.171 .9517.601. 5 5 S.5 S.4 5.7 5.0 5.E 5 5.9 5.5 5., 5.2 5, 5.0 5.1 1.9 5.4 5.3 5.0 5.6 5,o• 3 5.9 5.4 5.1 5.9 .9 1.0 5.6 5.2 5.B 5.5 5.3 5.3 5.4 5.6 1.1 S.o 5.6 5.0 5 1., 5.9 5.1 _1,1.2 5.9 S 9 6 52 6 9 8 5 S E S 6 g S g 3.16 15.25 16.5] 1].191'.52 35.63 1t 5.3 5., 5.o 5.0 5.4 S.rys1t.1 5.3 1., 5.9 5.1 1.4 to 1.o 5.o 1.- 1.0 5.E 5.a 5.s 5.0 5.7 5.0 S.o 5.1 5.9 S.E 5.0 5.5 5.9 /.a 5.8 5.5 5.2 5.6 5.3 1.9 1.7 tB 3.0 5.6 5.4 5.0 _ _ _ _ _ _ _ .F.:15 _ GE 5.7 t.^ 5.7 5.7 5.0 9.1 '0.1 5s 1 0 1.4 1.0 5.9 1.1 1.3 0.19 5 E IS., 5.0 5.: 5.. 1.5 5.7 5.9 5.9 5.7 5.3 5.7 1.1 00005 50 5 , 00r..,-71.. a 4 4 4 ,0000 .1 1 So 11.c000000 1 a 13.3 5.1 1.0 000° 1 5,1 5., 5.1 5.1 S.E 3 G 5.6 S 5 5 3 8 -100 5_ 5.3 5.1 S.o 1 4, 45.1 �_.0 91.9 5.0 4'•_.1 5.3 25-'1 5.5 0.1_.7 5.9 23.0 5.3 ., 5.0 73•,.o 5.0 55.05.o 5 5.3 5., S-5_ 5.2 5.1 1.4 3., 5., 5.2 5.5 S.B t.1 5.2 5,,, 5.4 5.4 13 5.5 5.2 1. 5 4 ,, 5 5 •.P 5.4 3.9 5.6 5.9 5, 5.5 5.9 5.3 5.7 5.5 5.0 1., 5.55 5.5 5., 1.1 5.7 5 5 5 5.7 5.0 5.a 5.6 100 1.9 5.4 5.7 5.: 5.7 5.1 0.0 5.1 5.7 5.0 5.6 S.: S �, t, v �?.6 = E 1 t 5., 5500 5.6 �1 S.3 1.7 t.3 Os -t.5 5., 5 5, 5.6 5.4 5., 5.4 5., 5, 30.1 30.4 S. S. 5.5 t.9 1.0 5 88 84 ea t7 1, 5, S.o S. 5.1 t.7 10.? 155.8 11.6. So.3 5.7 1-E S.2 t.: 5 - 1.9 5.= 5.3 S.o 1.4 Soo So., 11.0 11.1 11. 30.. 30.3 1.7 5, 5, 5.1 5 a ea et 84 t.0 1.4 5., 5.: 5.5 Io,5o.F 11.0 31.0 So.- 30,5 So.o 5:3 5.3 5., 5.5 5 JO 0 i *El.) t.1 '''.15.6 5.2 5.5 10.0 Y0 °o So., So.e So. 3 5.9 5.4 5.l 5.] 5.3 5.5 1 j DD De /J 5.0 1.4 5.5 5.1 5.4 5.e 1001 100.2 10.0 5.E 5.4 3.1 1.00 j,' !�,5 5.9 5.3 5.4 5.0 5.: 5.5 t., t.7 S.•, 5.4 5., • 5.o /0L.5.5 5.5 5.5 5.5 S_2 5.9 5.3 5.4 5.4 5.= L6 5.5 S. CA . 5.1 5.2 5.E 5.0 to 5.1 5 9 5.3 5.2 5.8 5.2 Ll 5.5 5.7 5.6 5.2 5.E 5.1 5.55 S.F 5.0 5.1 S.E 5., 5.1 4'.1' 5.0 5.2 5.4 5.5 S 5.e t.6 5.5 5.2 5.4 5.7 5., 5.0 5.05.4 5.8 5.9 5.0 59 t._ 5.5 5.3 000 t.l t., 5.6 5.5 t.l 1.2 5.1 5 t.0 t., 5.6 S., 5.3 S.E S.a S.0 500 5 1.3 5.5 5., 1.2 0.88 3:.50 10 17 13 9.2 1 .30 52.3 1 7 3^ '311 .51 11.az t X5.4 S.a 1.o 5.1 5., 1.7 1.1 5 0.r;, Mr -a.-- iffitigIF1 NTRy VESTtBU1E S.E 1.5 3.1 5.6 5 87 5,46 13.81 196 5.19 _.300 °5{05 5.45 5.54 5.56 S. 2 3.60 5.3°1.69 5.74 S.63 Ll 5. 6 3.600 5.2E 5.65.63 5.52 •.70 3.35 3.94 5.24 5. 5.1E • 5.16 S.o, 5 15.S.a]tr 5. 2 3.04 3.45 /.,2 3.6 %� 5 5 f 3.62 5.99 3.45 ;11041 .c 0 3 3.2,1 1 ,/oR< 5.-3 3.07 3.46 1.66 1.5_ • iI• 1.7711 t.3e'.,1 1.1rI1111.,1 8 4 6 2 S.o 5.1 5 3 to 5.0 5- S.'1 5.1 _.. __ __ _._ _. _._ _. _. _._ _._ _._ e 1., 1.00 .0 1.9 5.0 _.1 5., 5.1 5.2 1.9 1.8 11.6 5.1 5.3 5.4 5.o 1.6 1.1 5.9 5.00 5.5 55.7 b ' 0 0 9 5.5 S.a�1.2 t.0 --_ E �.1 3 1 - •l.o 1.3 5.1 • 5.0 5., 1.6 1.7 8i .9 1.0 S 3 i.6 01' 1.0 rr�e 5.6 5.1 1.5 5.3 t.=_ 5.1 1.E 5.5 3.4 S. 1.E 1.1 5.e 5.6 3.00 to 5.6 5., 5.5 1.4 42.0 �. 1.00 5,, l 1.6 59 ..0 5.3 5 2 i.o 5.1 S. 4.93 17.00 17.78 1 .49 16.14 5 LANOL RD ELECTR CAL ROOM MIN 5.0 5.s .0 5.5 5.] 113.. 3.4 5.2 5.9 5.6 5.9 5.7 5. S.3 5.9 S.2 5.9 5.5 5.2 5., 5.9 5.0 5.5 5.0 r.4 5.e 1.E 5.2 S.o 5.1 5.0 5.4 1.7 5.3 5.2 5.4 1.8 5.7 S., 1.0 5.7 4.9 5.7 S.., 5 3 1.5 p q p A • Epp.8��715.2: 19.851 .6118.131 S.1 5.5 5.7 5.: 5.5 5. 1.00 1.2 5 _ 1.6 1.9 1.3 5.9 5.6 1► •Y .4 5.6 l.5 to '1.3 1.3 7.5 5.s 09 1.0 45, Bo .o 5.0 Io 5.1 5.1 A 5 L F } 8.10 110.41 555.92 19.4, 1 S.3 51 5 7 5.2 59 5, 5.6 5 59 10 53 SE •, 5. 5.4 tE 5. t.a`=1ta t.4 1P ta 5.1 S1 Q S g $ 5.5 1.900 .3 5.e 1.7 5.1 5.5 3.8 S. 5.0 1.6 1.2 1.1 1.4 1.a 5.8 .B 5.5 5.6 5.5 5.4 S.o 1.9 1.4 i.. ( 1 i 8.54 50.61 95 .06 19.6E 51 • , 1.9 0.o 1.1 5.9 5.7 5.0 5.E 5.9 l.0 5.3 5., 5.4 S.3 5.6 5.0 5 5.5 5.0 1.9 5.6 5- 1.4 5.6 1.6 1.a �.0 • - 5 , .8 55..1 1. 0... -- �y E.]] 19.R2 0.65 5 .45 418.98 1 Be L w - 5.7 5.9 5.3 5.3 5.3 5.0 1. 5.6 S.o S.22 3.5 5.}, 5.s S. 5.1 S. 5.6 5 5.5 5_ S. 5.3 3.2 5.5 5.9 0.0 5.0 5 : .1 S.E 5.3� V - g - g� - 2.58 16.23 18.3819.171 .9517.601. 5 5 S.5 S.4 5.7 5.0 5.E 5 5.9 5.5 5., 5.2 5, 5.0 5.1 1.9 5.4 5.3 5.0 5.6 5,o• 3 5.9 5.4 5.1 5.9 .9 1.0 5.6 5.2 5.B 5.5 5.3 5.3 5.4 5.6 1.1 S.o 5.6 5.0 5 1., 5.9 5.1 _1,1.2 5.9 S 9 6 52 6 9 8 5 S E S 6 g S g 3.16 15.25 16.5] 1].191'.52 35.63 1t 5.3 5., 5.o 5.0 5.4 S.rys1t.1 5.3 1., 5.9 5.1 1.4 to 1.o 5.o 1.- 1.0 5.E 5.a 5.s 5.0 5.7 5.0 S.o 5.1 5.9 S.E 5.0 5.5 5.9 /.a 5.8 5.5 5.2 5.6 5.3 1.9 1.7 tB 3.0 5.6 5.4 5.0 _ _ _ _ _ _ _ .F.:15 _ GE 5.7 t.^ 5.7 5.7 5.0 9.1 '0.1 5s 1 0 1.4 1.0 5.9 1.1 1.3 0.19 5 E IS., 5.0 5.: 5.. 1.5 5.7 5.9 5.9 5.7 5.3 5.7 1.1 00005 50 5 , 00r..,-71.. a 4 4 4 ,0000 .1 1 So 11.c000000 1 a 13.3 5.1 1.0 000° 1 5,1 5., 5.1 5.1 S.E 3 G 5.6 S 5 5 3 8 -100 5_ 5.3 5.1 S.o 1 4, 45.1 �_.0 91.9 5.0 4'•_.1 5.3 25-'1 5.5 0.1_.7 5.9 23.0 5.3 ., 5.0 73•,.o 5.0 55.05.o 5 5.3 5., S-5_ 5.2 5.1 1.4 3., 5., 5.2 5.5 S.B t.1 5.2 5,,, 5.4 5.4 13 5.5 5.2 1. 5 4 ,, 5 5 •.P 5.4 3.9 5.6 5.9 5, 5.5 5.9 5.3 5.7 5.5 5.0 1., 5.55 5.5 5., 1.1 5.7 5 5 5 5.7 5.0 5.a 5.6 100 1.9 5.4 5.7 5.: 5.7 5.1 0.0 5.1 5.7 5.0 5.6 S.: S �, t, v �?.6 = E 1 t 5., 5500 5.6 �1 S.3 1.7 t.3 Os -t.5 5., 5 5, 5.6 5.4 5., 5.4 5., 5, 30.1 30.4 S. S. 5.5 t.9 1.0 5 88 84 ea t7 1, 5, S.o S. 5.1 t.7 10.? 155.8 11.6. So.3 5.7 1-E S.2 t.: 5 - 1.9 5.= 5.3 S.o 1.4 Soo So., 11.0 11.1 11. 30.. 30.3 1.7 5, 5, 5.1 5 a ea et 84 t.0 1.4 5., 5.: 5.5 Io,5o.F 11.0 31.0 So.- 30,5 So.o 5:3 5.3 5., 5.5 5 JO 0 i *El.) t.1 '''.15.6 5.2 5.5 10.0 Y0 °o So., So.e So. 3 5.9 5.4 5.l 5.] 5.3 5.5 1 j DD De /J 5.0 1.4 5.5 5.1 5.4 5.e 1001 100.2 10.0 5.E 5.4 3.1 1.00 j,' !�,5 5.9 5.3 5.4 5.0 5.: 5.5 t., t.7 S.•, 5.4 5., • 5.o /0L.5.5 5.5 5.5 5.5 S_2 5.9 5.3 5.4 5.4 5.= L6 5.5 S. CA . 5.1 5.2 5.E 5.0 to 5.1 5 9 5.3 5.2 5.8 5.2 Ll 5.5 5.7 5.6 5.2 5.E 5.1 5.55 S.F 5.0 5.1 S.E 5., 5.1 4'.1' 5.0 5.2 5.4 5.5 S 5.e t.6 5.5 5.2 5.4 5.7 5., 5.0 5.05.4 5.8 5.9 5.0 59 t._ 5.5 5.3 000 t.l t., 5.6 5.5 t.l 1.2 5.1 5 t.0 t., 5.6 S., 5.3 S.E S.a S.0 500 5 1.3 5.5 5., 1.2 0.88 3:.50 10 17 13 9.2 1 .30 52.3 1 7 3^ '311 .51 11.az t X5.4 S.a 1.o 5.1 5., 1.7 1.1 5 0.r;, Mr -a.-- iffitigIF1 NTRy VESTtBU1E S.E 1.5 3.1 5.6 5 87 5,46 13.81 196 5.19 _.300 °5{05 5.45 5.54 5.56 S. 2 3.60 5.3°1.69 5.74 S.63 Ll 5. 6 3.600 5.2E 5.65.63 5.52 •.70 3.35 3.94 5.24 5. 5.1E • 5.16 S.o, 5 15.S.a]tr 5. 2 3.04 3.45 /.,2 3.6 %� 5 5 f 3.62 5.99 3.45 ;11041 .c 0 3 3.2,1 1 ,/oR< 5.-3 3.07 3.46 1.66 1.5_ • iI• 1.7711 t.3e'.,1 1.1rI1111.,1 5.41 S.4, to' 5,1 1.001 Qty Label Arrangement Total Lamp Lumens _Total LLF MI 1.9F 5.90 T.3. 82 5.0 ,504 4 WM1 . 1- 5 , 5..00 1.92 5.99 1 csip 19 S.ol 5.,9 „,1 1. .3 5700 0.800 5.99 5.06 1.1 5. 5.1_ 1._ 5.,_ SINGLE 5700 3.57 5 86 `.2 5 90 •• 00 -. 1 3.86 5.85 .2 5.84 3.90 5800 0.800 to:169 ., 2.65 1.71 S.,, 1 11-,5 5._, 8 594 SE, 1 , to, eqo 5o, 5 •. 5. 5 6 .0 5.35 •.o9 5.12 11.58 _m: 1 .1 1 1.61 i.6. 1 i5 1 o6 5 1 44 1 13 5..0 5.3. 5.x•.5_ S.,, S. 5.007 E cl 1.1 -a, t 60 t �t 5.69 5.31 6'5.1_ t 6 i 15f 1 -,1. 5.FE S.00 5 5. 3 5.52 •S. 5 e 5.1 5.:0 3.19 5 o2 5.,,/1.63 1.39 1.19 t 5.7 5.1 -ICA 5.4 -.aa 5.69 1. 5.5 3 SME'J,0 1.93 5.51 5.42 5.. t.: 5.1 1.7. 7i 5.82 1.20 5. torr .91 1.41 10.53 11.94 13.21 3 .89 5.54 5_4 1.00, 412.05�1 35 11 9d5 ,901 E, lS.Rl 5.5 5.7,.� 112 •o.00 5.9=_ 5.5, 5.,8 5., 5. ;17;17:872. _ 00 11.14 5.65 11.12 ,6 16.4_9 16 .90 5.3, 11.86 13.54 34.3, 14.0 3..26 1.19 5 5 32.64 14.62 35.29 35.92 15.65 5,. 66 15.17 15.91 14.50 36.13 16.54 1,.16 37.53 30. 5 3 2.1E 2.,0 11.24 12.96 1,,,,t1.9, 16.38 1 .80 18.42 18.31 17.28 16.84 18.01 18.21 38.19 39.74 19.38 39.11 18. E 1.. 12.44 14.32 3o.33 16.15 11.94 5 .66 30.31 50.19 100.83 16.02 19.56 50.33 50.22 10.90 31.23 30.99 50.83 1' 5.63 1.19 5. 1 3 5.50.13 5., S OMEN a • 900 5 oa 1.05 5.91 1. e 5 111 NIT .29 11.67 53.31 1 5.56 5.1, 11.8 15.40 5_.oa 4, 75 4 5.54 So. ,1 .100 S.lo 5o.67S5.E3 5.26 13. a 1 .000 10.009 56. 3 16.66 13.21 19.67 19.17 14.00 5o. op 13.46 19. 1 .10 13.72 15.10 55 35.17 35.05 54 13.13 13.49 36.02 38.2E 59._, 39.9.'. 17.06 18.995 eb 51.62 19.80 19.03 19.50 51.8''1'.17 53.13 50.11 12.27 36.65 15.26 5 .50 52.37 39.9, 100.0000 100.96 32.8 43.x3 5,.,13 31.59 32.5E 3]_002 _1.53So 1 °.931 ba15, 17 ST €WR5fl 5 .00 1,.06 1 57736.55 3"'36.69 1 3^ •0 ^9 •1 as •1 1310 14.00 17.002 _. _ __ ,AO. 15 ,7 5.3E 1_ 13.6 10.51 1.53 3.34 _1.9918.25 3.98 10 12.]8 18.95 18.75 31.54 36.81 16.46 5.16 13.25 55.5a 1.38 5o. 0 0 .00 5.53 S.5 5.92 5.7`3. 1.22 5.2 5.66 11.80 3 .46 18.29 35 15.56 13.07 15.86 57 32.94 3 .52 11.33 5P 50,13 • ((s. '25 5.11 5 .06 18 5.25 53.14 1.42 18 15.57-5-./a , 14.5 15.54 14 o 16.53 18.02 11 '7 1,.31 So.24 19.4 1 911, '- 19. R 5 19 19 Electrical Room Illuminance (Fc) Average = 8.70 Maximum = 15.3 Minimum = 1.3 Avg/Min Ratio = Max/Min Ratio = = MALL STORAGE 9 77 Stock Room Illuminance (Fc) Average = 15.92 Maximum = 24.4 Minimum = 1.5 Avg/Min Ratio = 10.61 Max/Min Ratio = 16.27 18.29 30.11 16 :1 17. 5 3 .12 36 75 37.65 1, 10 39. 3 5 .300 100.02 15.21 10 9 50.54 3 .06 53.0.05 10 15 1. '1..05 12.1 1?.60 31. _ _ 1 .32 11.32 16.59 19 .1, 18.06 31.19 2.02 5 .11 5.15 5.27 1.52 10.22 16.29 1 .009 19.93 19.40 16.09 1^_.11 12.83 16.26 10.57 18.18 18.09 18.96 19.28 1 .9'1 TERRACE 30 1.0 as 1.36 77 3.90 5.6, 1.16 3.77 1.58 1.11 S.a= 5-66 3.19 5.:4 1.39 3.93 5.12 1.89 1.17 1.16 1.18 1.19 1.92 5l 1.95 3.35 5.: Soo S.o!5.00 S.00 5.455 1.10 3.12 3.50 5..2 501 1�,6 5.as 5.: 1.35 5.90 5.15 3.92 1.12 1.10 5.10 3.11 3.93 5.13 3.9836 3 So 1 104 1 STORF MGR 10, GENERAL MANAGER Escalator Break Room S S S Average = 3.94 Maximum = 5.5 Minimum = 1.2 Avg/Min Ratio = 3.28 Max/Min Ratio = 4.58 Illuminance (Fc) Average = 17.73 Maximum - 25.6 Minimum = 6.8 Avg/Min Ratio = 2.57 Max/Min Ratio = 3.71 Front Entry Illuminance (Fc) Average = 3.89 Maximum = 6.8 Minimum = 2.3 Avg/Min Ratio = 1.69 Max/Min Ratio = 3.00 Luminaire Schedule Symbol Qty Label Arrangement Total Lamp Lumens _Total LLF Description 82 E1-TC922LED=3K+27C= SINGLE 0.800 TC922LED-3R WITH 27C -WH csip 19 Al-ICDM8=2-32 SINGLE 5700 0.800 ICDM8-2-32 2 B1-XP2GVA232 SINGLE 5700 0.800 XP2GVA23212050 -. 1 K1 -C 2 32 MVOLT GEB1OIS SINGLE 5800 0.800 C 2 32 MVOLT GEB1OIS 1 • 1 7 Dl -AEI #T8L 632 H #11855 SINGLE 11400 0.800 modified for 4 lamp fixture EMERGENCY LIGHTING CALCULATIONS - SECOND FLOOR PLAN 1/8.=1.-o" REVIEWED FOR COMPUANCE WITH NFPA70 - NEC JUL 2 2 2013 City of Tukwila BUILDING DIVISION EL3Ok39 RECEIVED CITY OF TUKWILA JUN 28 2013 PERMITNTG. E... i L COIf 40 O 410 E2 4--1 C O N ® 03 CD ♦Ce O Q V N a c © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM (f) m ZQJ -J00 Li W D- w U W Q J Z I- I- ZOOF (f) (f) I- ° - ) rD n 0 0 0 0 0 0 0 0 0 0 0 0 0 D No. Date Item REVISIONS JA Drawn TG Checked TO Approved EMERGENCY LIGHTING CALC'S SECOND FLOOR Project No. 13007.00 Date PERMIT - 06.24.13 Last Revision E-4.0 ELECTRICAL PLAN NOTES: 1❑ UNDERFLOOR CONDUITS AS REQUIRED FOR POWER TO POS STATIONS. STUB UP CONCEALED WITHIN MILLWORK. PROVIDE MC CABLE WHIPS FROM FLOOR PENETRATIONS (JUNCTION BOXES) TO DEVICE LOCATIONS WITHIN MILLWORK. PROVIDE DEVICES IN LOCATIONS WITHIN MILLWORK AS DIRECTED BY TCS PROJECT MANAGER. PROVIDE FINAL ELECTRICAL TERMINATIONS, WIRING AND COVERPLATES WITHIN MILLWORK. COORDINATE ALL WORK WITH TCS PROJECT MANAGER. REFER TO PHOTOGRAPHS INCLUDED IN APPENDIX A IN PROJECT MANUAL. 121 PROVIDE UNDERFLOOR CONDUITS AS REQUIRED FOR DATA TO POS STATIONS. STUB UP CONCEALED WITHIN MILLWORK. PROVIDE COIL OF CABLE WITHIN MILLWORK FOR TERMINATION OF DATA AT LOCATIONS DIRECTED BY TCS PROJECT MANAGER. PROVIDE BOXES, CABLE, DEVICES AND TERMINATIONS FOR DATA LINES WITHIN MILLWORK. COORDINATE ALL WORK WITH TCS PROJECT MANAGER. REFER TO PHOTOGRAPHS INCLUDED IN APPENDIX A IN PROJECT MANUAL. 3 4 PROVIDE (1) WIREMOLD "RFB4—SS" STAMPED STEEL, ADJUSTABLE, RECESSED FLOOR BOX FOR CONCRETE FLOORS. PROVIDE WITH CUT—OUT COVER ASSEMBLY #FPCTAL, IN BRUSHED ALUMINUM FINISH. PROVIDE WITH (3) DUPLEX POWER OUTLETS AND (1) DATA OUTLET WITH (4) DATA CONNECTIONS. GC TO CONFIRM EXACT LOCATION WITH TENANT PROJECT MANAGER PRIOR TO INSTALLATION. VERIFY LOCATION OF CASH WRAP RECEPTACLES AND DATA OUTLETS WITH TCS PROJECT MANAGER PRIOR TO INSTALLATION. ROUTE CONDUIT WITHIN SLAB LEAVE OUT AND WITHIN MILLWORK AS DIRECTED BY TCS PROJECT MANAGER. REFER TO PHOTOGRAPHS INCLUDED IN APPENDIX A IN PROJECT MANUAL. REFER TO DETAIL #4, THIS SHEET FOR ADDITIONAL INFORMATION. u CONDUIT STUB UP THROUGH FLOOR INTO WALL. ROUTE POWER CONDUIT BELOW FLOOR TO CDC COLUMN ENCLOSURE, THEN OVERHEAD TO ELECTRICAL ROOM. ROUTE DATA CONDUIT BELOW SLAB TO CDC COLUMN ENCLOSURE THEN OVERHEAD TO . COMMUNICATION ROOM. REFER TO DIVISION 26 SPECIFICATION. RUN UNDER—SLAB CABLE BACK TO FALSE COLUMN UP TO STRUCTURAL AND RUN OVERHEAD TO SERVER RACK IN COMMUNICATION ROOM. 6 CONFIRM LAYOUT WITH TCS PROJECT MANAGER. PROVIDE RECESSED OUTLET BOXES SUITABLE FOR USE IN GWB PARTITION WALLS FOR DATA AND POWER RECEPTACLES. PROVIDE WITH MUD RINGS AND WHITE COVER PLATES. MOUNT AT 18" AFF. REFER TO DETAIL #4 ON THIS SHEET FOR MORE INFORMATION. 7❑ PROVIDE (1) WIREMOLD "RFB4—SS" STAMPED STEEL, ADJUSTABLE, RECESSED FLOOR BOX FOR CONCRETE FLOORS. PROVIDE WITH IN BRUSHED ALUMINUM FINISH. PROVIDE WITH (2) DUPLEX POWER OUTLETS AND (1) DATA OUTLET WITH 4 DATA CONNECTIONS AS INDICATED. GC TO CONFIRM EXACT LOCATION WITH TENANT PROJECT MANAGER PRIOR TO INSTALLATION. 8 n 10 11 i PEOPLE COUNTER MOUNTED AT CEILING CENTERED BETWEEN LIGHTS — GC TO PROVIDE AND INSTALL ONE CAT 6 CABLE STUBBED UP 6" BELOW CEILING THROUGH A 3/4" DIA. GROMMETED HOLE (NO BACK BOX OR FACEPLATE REQUIRED) TERMINATE END OF CABLE WITH A SYSTEMAX MALE CONNECTOR. REFER TO DIVISION 26 FOR PART NUMBER TAG CABLE 4" FROM END CABLE TO RUN BACK TO SERVER IN COMMUNICATIONS ROOM #107. ROUTE ELECTRICAL AND DATA CONDUIT UNDERFLOOR TO LOCATION SHOWN, THEN ROUTE OVER—HEAD BACK TO COMM. ROOM AND ELECTRICAL ROOM. PROVIDE NEW DOORBELL PUSH BUTTON AT EXTERIOR MULLION. DOORBELL PUSH BUTTON TO BE EDWARDS #59 LOW—VOLTAGE, HIGH AMPERAGE, PUSH BUTTON, WITH NICKEL PLATED RIM AND WHITE BUTTON. MOUNT IN METAL MULLION. WIRE TO NEW BELL IN BREAK ROOM AND STOCKROOM. ROUTE WIRING CONCEALED WITHIN WALL, CEILING AND WITHIN WIREWAY. MAKE FINAL CONNECTIONS PER BELL SYSTEM MANUFACTURER'S RECOMMENDATIONS. (1) DOOR BELL AT 2ND FLOOR TCS ENTRY AND (1) DOOR BELL AT 1ST LEVEL MALL ENTRY, BOTH DOOR BELLS WILL HAVE THE SAME CHIME. CONNECTION TO TRANSFORMER/BELL AT WALL IN BREAK ROOM AND IN STOCKROOM. REFER TO DETAIL 1/E-5.1 FOR TRANSFORMER/BELL LOCATION. tT. 2 0, cp cy) re, • 74 :54 1 ICC L. 03 00 00 'LI PROVIDE CONDUIT AND PULL STRING FROM DOOR CONTACT LOCATION TO SECURITY MONITORING EQUIPMENT. ROUTE ABOVE FINISHED CEILING OR VIA WIREWAY. 1131 ADT ALARM KEY PAD. COORDINATE ALL POWER/DATA REQUIREMENTS WITH ADT CONTRACTOR. CENTER ON PILASTER AT 60" AFF. NEW FIRE ALARM REMOTE ANNUNCIATOR PANEL. CENTER ON PALASTER AT 60" AFF. PROVIDE JUNCTION BOX FOR CONNECTION OF AUTOMATIC DOORS. COORDINATE EXACT POWER REQUIREMENTS WITH EQUIPMENT MANUFACTURER. 16 MOUNT DATA JACK IN CASHWRAP FOR THE INDYME ANTENNA (ANTENNA PORTION EXPOSED). LABEL IN COMMUNICATION ROOM ALL CONDUIT SERVING EQUIPMENT IN THE ENTRY AREA SHALL BE CONCEALED WITHIN WALLS AND WINDOW FRAMEWORK. RUN DATA CABLE VIA PATHWAY FROM DOOR JAMBS FOR JAMB CAMERAS PROVIDED WITH DOOR PACKAGE. COORDINATE INSTALLATION OF CAMERAS AND CABLE WITH DOOR MANUFACTURER AND CAMERA INSTALLER. PWP I 11111111111111111111/1111t111/11,11111.111 KONEJ 17 N UP 18 19 i / I I I I I 20 21 1 I I I J CONDUIT AND WIRE SERVING POWER AND DATA DEVICES SHALL BE RUN OVERHEAD AND TO MILLWORK VIA A INSIDE COLUMN. POWER AND DATA RECEPTACLES SHALL BE MOUNTED TO MILLWORK. ELECTRICAL CONTRACTOR SHALL REFER TO PHOTOGRAPHS PROVIDED IN PROJECT MANUAL. RUN CABLE THROUGH PATHWAY IN CABINET AND TERMINATE. cu © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG Err BM UNDERFLOOR DATA CABLE IS NOT PLENUM RATED AND SHALL RUN IN CONDUIT (AS REQUIRED) BACK TO THE COMMUNICATIONS ROOM SERVER RACK. REFER TO DIVISION 26. 22 ROUTE ALL POWER (CONDUIT & WIRE) OVERHEAD FROM COLUMN ENCLOSURE TO ELECTRICAL ROOM AND ALL DATA CONDUIT OVER—HEAD TO COMMUNICATION ROOM. 23 ALL EXISTING ELEVATOR DEVICES SHALL BE RE—CIRCUITED FROM EXISTING PANEL 'LC' TO NEW PANEL 'EP'. CONTRACTOR SHALL REMOVE PANEL 'LC' AS REQUIRED AND REPLACE WITH NEW PANEL 'EP'. UNDLESS NOTED OTHERWISE. 24 EXISTING 4 FT FLUORESCENT FIXTURE WITH TWO T-8 LAMPS AND ELECTRONIC BALLAST. p ALL EXISTING ESCALATOR DEVICES SHALL BE RE—CIRCUITED FROM EXISTING PANEL 'LC' TO NEW PANEL 'EP'. CONTRACTOR SHALL REMOVE PANEL 'EC' AS REQUIRED AND REPLACE WITH NEW PANEL 'EP'. UNDLESS NOTED OTHERWISE. 26 29 ENLARGED 'CASH WRAP' & 'FRONT VESTIBULE' - POWER ENLARGED FIRST FLOOR PLAN - ELEVATOR ROOM - POWER 30 EXISTING DISCONNECT SWITCH TO REMAIN AND TO BE REUSED. NOT USED EXISTING JUNCTION BOXES FOR TELEPHONE INTERFACE AND FIRE ALARM ELEVATOR RECALL AND CONTROL. NOT USED PROVIDE 3/4" CONDUIT AND PULL STRING FROM DOOR CONTACT LOCATION TO SECURITY MONITORING EQUIPMENT. ROUTE ABOVE FINISHED CEILING OR VIA WIREWAY. REFER TO BAS DRAWINGS FOR SECURITY MONITORING EQUIPMENT LOCATION. (JO 02 75 00- 11-1 CD Li F- DANCE FLOOR: 3 c0 00 091 0 IALL DATA CONDUITS WILL BE IN 1" DIAMETER UNLESS NOTED OTHERWISE si4) REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. IREFER TO SHEET E-7 AND E-8 FOR RECEPTACLES REQUIRED TO HAVE SPD. CA 21 Gift Registry CA 25 23 19 3'-3 3/8" 22 ALL EQUIPMENT TO BE INSTALLED BY TCS. ENLARGED ELFA — CUSTOM PLANNING: bracket /1114 • ENLARGED 'CASH WRAP' POWER ENLARGED 'WOW' ENCLOSURE POWER monitor 7-1/4" 3" 7-1/4" pole SURGE PROTECTOR ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL 1" DIAMETER CONDUIT PATHWAY INSIDE WALL FROM 1" OPENING (A) TO 1" OPENING BELOW (B). APPROXIMATE LENGTH OF CONDUIT IS 3'-4" (VERIFY IN FIELD). .60 7 7 brocke GIFT RE CPI -REVIEWED FOR COMPUANCE WITH NFPA 70 - NEC Tronsforme equipmen box 1:11:1E12 1:14 A-9 MOUNT AND FLUSF ALL ELECTRICAL COMPONENTS TO THE TOP EDGE OF THE UNIT. JUL 2 2 2013 UILDING DIVISION A-9 CI CI 00 0 CI CIO CIO 3,-4" 6nyRNETIuVEvilDil PERMIT CENKTE 4"x5"H. PASS THROUGH SPACE FOR WIRES GIFT REGISTRY - ELEVATION NO SCALE I I I I ENLARGED 'SALES ELFA CMC & 'GIFT REGISTRY'PLAN ® SI?C CABINET LI" -0 03'1 No. Date Item Drawn Checked REVISIONS ENLARGED 'SALES FLOOR' POWER PLAN Project No. 13007.00 Dote PERMIT — 06.24.13 Last Revision E-5.0 800 AMP DISC. (EXISTING TO BE REMOVED) (2 SETS)OF 4J600KCMIL + /0GND IN 4 CONDUIT (EXISTING TO BE REMOVED) EXISTING 4" DIA CONDUIT FOR TELEPHONE AND DATA TO BE ABANDONED L — ..OR. CONTiN:UATIO REF EPM•-4000 SUB -METER NEL SUB -METER PANEL 391- 41H . ALL . EQUIPMENT. IN. THIS • EXISTING TO REMAIN FOR CONTINUATION REFER TO 1 /E. 1 L1 18 (PART) ®I ILII -MA IMEI (5)4"C. 4 6UUKCMIL, 1#250KCM1 GR DOWN - 1 2000AF, 2 OAT SWITCH IN 3000 A P 3 PH., 4W. 0 B 65KAIC, 'S RVICE ENTRANCE RATED' SWI CHBOARD #4S2 ENLARGED 'DEMOLITION PLAN' ®PREVIOUS TENANT'S SERVICE 1/4"=1'-0" ELECTRIC ROOM 24 PS 22 23 21 UPS UPS 13 PNL L1 XFMR UPS PNL/ XEMR_ J 1 8 INTEGRATED SWITCH EAR — EF -2 L1 18 PART) PHONE BOAR 0 1 UPS �lPS UPS 14 12 MOTE PNL SEC. ADT AL1 18 (PART) DROP (1) 2" DIA. CONDUIT AND (2) 1" CONDUIT FOR TELEPHONE AND DATA TO PHONE BOARD WOMEN STO�K ROOM 2. 35 SF RTU -X H1 26 0 1/NF STORE MG 6"JIFF A 32"AFF POS/GEN GENERAL MANAGER ENLARGED 'BACK OF HOUSE' 1 /4"= 1 '1'ICEO"S/STOCKROOM' POWER PLAN OFF - ELECTRICAL KEYED NOTES: E1 PROVIDE EDWARDS #432-G5, 24VAC, 4" DIA. (VIBRATING) BELL. MOUNTED AT 6" ABOVE CEILING, CENTERED OVER DOOR, ABOVE CEILING, PROVIDE EDWARDS #598-120V TO 24VAC, 30VA TRANSFORMER ABOVE CEILING. MAKE ALL FINAL CONNECTIONS FOR A COMPLETE, FUNCTIONAL SYSTEM. 2 3 4 5 6 7 8 (2) #14 TO NEW DOOR BELL PUSH BUTTON AT FIRST AND SECOND FLOOR MAIN ENTRY VIA WIREWAY. REFER TO 1/E-3.0 FOR PUSH BUTTON LOCATION. POWER FOR ELECTRIC DOOR STRIKE, MOUNT 6" ABOVE CEILING OR ABOVE DOOR, IN EXPOSED AREA. COORDINATE LOCATION WITH BAS DRAWINGS. VOLUME CONTROLS MOUNTED 48 AFF. LIGHTING CONTROLS MOUNTED AT 40" AFF. CARD READER AND ELECTRIC STRIKE. MOUNT AT A MAXIMUM OF 6" FROM DOOR JAMB AT +48" AFF. PROVIDE (2) 60A, 1 -POLE, NON-FUSED DISCONNECT SWITCH FOR WH -1. DISCONNECT SHALL BE LABELED 'WH -1'. OVERHEAD DOOR PUSHBUTTON. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE LOCATION WITH ARCHITECT AND TCS PROJECT MANAGER PRIOR TO ROUGH -IN. NEW INTEGRATED FACILITY SYSTEM(POWER WALL) TO BE INSTALLED BY ELECTRICAL CONTRACTOR. REFER TO SHEET E-6 FOR ONE -LINE DIAGRAM AND POWER WALL DETAIL. CONTRACTOR SHALL COORDINATE PURCHASE AND INSTALLATION WITH W.R. CONTROL PER TYLER WALKER (PHONE: 614-934-6416). CONTRACTOR SHALL PROVIDE (1) NEMA L6 -30R TWIST -LOCK RECEPTACLE IN A JUNCTION BOX ON RIGID CONDUIT MOUNTED TO THE BOTTOM OF ROOF STRUCTURE AND (1) STANDARD NEMA L5 -20R TWIST -LOCK DUPLEX RECEPTACLE IN JUNCTION BOX TO BE LOCATED 12'-0" AFF ON RIGID CONDUIT. 10 POWERWARE MODEL 9170(12 SLOT) WITH (3) 3kVA/2.5kW SPLIT PHASE MODULES WITH (14 STRING) 49 MINUTES OF BATTERY BACK-UP TIME AT 9 KVA/7.5 KW. UL 1778 RATED. 208 VOLT/SINGLE PHASE INPUT (2 WIRE, PLUS GROUND). 208/120 VOLT SINGLE PHASE, 3 WIRE PLUS GROUND OUTPUT. 11 PROVIDE JUNCTION BOX AND CONDUIT FOR RTU SENSOR AS INDICATED. COORDINATE LOCATION WITH MECHANICAL CONTRACTOR, TCS PROJECT MANAGER AND BAS CONTRACTOR PRIOR TO ROUGH -IN. MYERS POWER PRODUCTS, INC. ILLUMINATOR SERIES E -7-S 8KVA 8KW-EMERGENCY LIGHTING INVERTER WITH BATTERY SYSTEM TO PROVIDE 90 MINUTES OF BACK UP AT FULL LOAD. 12 13 14 15 16 17 18 19 NOT USED. PROVIDE A 20 AMP GFCI RECEPTACLE UNDER SINK FOR POWER CONNECTION TO AUTOMATIC SOAP DISPENSER AND PAPER TOWEL DISPENSER. REFER TO MANUFACTURERS INSTRUCTIONS FOR EXACT MOUNTING DETAILS. REFER TO ELEVATIONS ON SHEET E7.0 FOR PAPER TOWEL DISPENSER LOCATION. PROVIDE 3 DATA LINE WITH TERMINATIONS FOR CONNECTION TO DIVCON PANELS IN POWERWALL. COORDINATE MOUNTING HEIGHT AND LOCATION WITH TCS PROJECT MANAGER PRIOR TO ROUGH -IN. PROVIDE JUNCTION BOX FOR POWER CONNECTION TO DIVCON PANEL 'ADM1'. COORDINATE INSTALLATION, POWER CONNECTION AND POWER REQUIREMENT WITH DIVCON PRIOR TO ROUGH -IN. PROVIDE A 20 AMP GFCI RECEPTACLE UNDER SINK FOR POWER CONNECTION TO GARBAGE DISPOSAL. INSTALL DISCONNECT SWITCH FOR OVERHEAD DOOR. CONNECT TO DOOR MOTOR PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE DISCONNECT LOCATION WITH ARCHITECT AND TCS PROJECT MANAGER PRIOR TO ROUGH -IN. REFER TO SHEET E3.0, DETAIL 2 FOR MOUNTING HEIGHTS OF COMBINATION TEMPERATURE AND HUMIDITY SENSORS. 20 JUNCTION BOXES FOR LIGHTING ELCU-200 UNITS ON PHONE BOARD. 21 PROVIDE GFI POWER RECEPTACLE FOR POWER TO AUTOMATIC PAPER TOWEL DISPENSER. ELECTRICAL CONTRACTOR SHALL COORDINATE DISPENSER & RECEPTACLE LOCATIONS WITH FRAMER, PRIOR TO ROUGH -IN. ELECTRICAL CONTRACTOR SHALL REFER TO PAPER TOWEL DISPENSER MANUFACTURER'S CUT SHEET FOR ALL ELECTRICAL REQUIREMENTS, PRIOR TO ROUGH -IN. REFER TO ELEVATIONS ON SHEET E-7.0 22 23 MANUAL OVERRIDE SWITCHES FOR FLOOR LIGHTING (5) SINGLE GANG BOX AND FACE PLATE (WHITE). NOT USED 1T4-1 PROVIDE (1) 120 VOLT DEDICATED CIRCUIT AND (2) JUNCTION BOXES AND 120/24 VOLT TRANSFORMER FOR POWER TO MOTORIZED DAMPERS. VERIFY ALL ELECTRICAL REQUIREMENTS WITH MOTORIZED DAMPER MANUFACTURER PRIOR TO INSTALLATION. REFER TO MECHANICAL PLANS FOR MORE INFORMATION. 25 27 28 29 30 31 32 PROVIDE NEW DOORBELL PUSH BUTTON AT EXTERIOR STOCKROOM DOOR. DOORBELL PUSH BUTTON TO BE EDWARDS #59 LOW -VOLTAGE, HIGH AMPERAGE, PUSH BUTTON, WITH NICKEL PLATED RIM AND WHITE BUTTON. MOUNT ON EXISTING WALL. WIRE TO NEW BELL IN BREAK ROOM AND STOCKROOM. ROUTE WIRING CONCEALED WITHIN WALL, CEILING. MAKE FINAL CONNECTIONS PER BELL SYSTEM MANUFACTURER'S RECOMMENDATIONS. PROVIDE EDWARDS #340A -G5, 24VAC, 4" DIA. VIBRATING BUZZER. MOUNTED AT 6" ABOVE CEILING, OVER DOOR, AND EDWARDS #598-120V TO 24VAC, 30VA TRANSFORMER ABOVE CEILING. MAKE ALL FINAL CONNECTIONS FOR A COMPLETE, FUNCTIONAL SYSTEM. (2) #14 TO NEW DOOR BELL PUSH BUTTON AT STOCKROOM DOOR. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO MAIN ELECTRICAL SERVICE, SWITCHBOARD, OR PANEL BOARDS SHALL BE PERMITTED TO BE LOCATED WITH THE DEDICATED SPACE ABOVE SUCH ELECTRICAL EQUIPMENT. PROVIDE A 120 VOLT, 20 AMP CIRCUIT FOR POWER TO COFFEE MAKER. REFER TO SHEET E -1.R FOR POWER TO EXHAUST FAN. PROVIDE 3/4" CONDUIT AND PULL STRING FROM DOOR CONTACT LOCATION TO SECURITY MONITORING EQUIPMENT. ROUTE ABOVE FINISHED CEILING. PROVIDE (2) 60A, 1 -POLE, NON-FUSED DISCONNECT SWITCHES FOR WH -2 DUAL ELEMENT INSTA-HOT. DISCONNECT SHALL BE LABELED 'WH -2'. 33 PROVIDE JUNCTION BOX FOR POWER CONNECTION TO DIVCON PANEL 'ADM1'. COORDINATE INSTALLATION, POWER CONNECTION AND POWER REQUIREMENT WITH DIVCON PRIOR TO ROUGH- IN. COORDINATE LOCATION WITH TCS PROJECT MANAGER. 34 CONTRACTOR SHALL PROVIDE (2) 208V/1PH, NEMA TYPE L6 -20R RECEPTACLES, REFER TO COMM. ROOM ELEVATIONS ON SHEET E7 FOR MORE INFORMATION. P1 NOT USED. 36 37 38 39 40 41 REFER TO ONE -LINE DIAGRAM(SHEET E6.1) FOR FEEDER AND CONDUIT SIZES. CONTRACTOR SHALL RUN FEEDERS OVERHEAD AND TIGHT TO STRUCTURE. CONTRACTOR SHALL CONNECT FEEDERS AND CONDUIT INTO EXISTING SWITCHGEAR '2A' AND SHALL REPLACE EXISTING 800 AMP SWITCH WITH NEW 1000 AMP SWITCH. REFER TO SHEET SHEET E6.1 FOR ONE -LINE DIAGRAM CONTRACTOR SHALL CONNECT NEW FEEDER AND CONDUIT TO NEW IFS INTEGRATED SWITCHGEAR. REFER TO SHEET E6.1 FOR ONE -LINE DIAGRAM. CONTRACTOR SHALL RUN (1) NEW 2" DIA. CONDUIT WITH NEW 25 PAIR PHONE CABLE EXTENSION FROM EXISTING LANDLORD'S DEMARK TO NEW PHONE BOARD IN ELECTRICAL ROOM #112 EXISTING 4" DIA VERTICAL CONDUIT TO BE ABANDONED AND ANY EXISTING DATA AND TELEPHONE CABLES TO BE REMOVED. CONTRACTOR SHALL SHALL RUN (2) NEW 1" DIAMETER CONDUITS FOR EIGHT (8) CAT6 LINES (EXT -1 THROUGH EXT -8) FROM LANDLORD'S DEMARK LOCATION TO PHONE IN TENANT'S ELECTRICAL ROOM (REFER TO SHEET E-8 FOR ELEVATION OF PANEL BOARD. CONTRACTOR SHALL KEEP CONDUIT TIGHT TO STRUCTURE. REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. REFER TO SHEET E-7 AND E-8 FOR RECEPTACLES REQUIRED TO HAVE SPD. i REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC JUL 2 2 2013 City of Tukwila BUILDING DIVISION [L13-0 63'1 RECEIVED CITY OF TUKWILA JUN 2 8 2013 PERMIT CENTER U 70LO - m0 E CD g ® maCD c~ 0 1te p CO ✓ N C/) 0 © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM H J I-- Jm oo J Q00 r 0_Wz U W J zF— <� 000 Cr) ~ Co n 0 0 0 0 0 0 0 0 g 0 0 0 No. Date Item REVISIONS TG Drawn TG Checked TG Approved ENLARGED 'BACK OF HOUSE' POWER PLANS, NOTES AND DETAILS Project No. Date Last 13007.00 PERMIT — 06.24.13 Revision E-5. 1 i o 0 NI TENANT OCCUPANCY TYPE: M TENANT SQUARE FOOTAGE: 22,000 SERVICE DESCRIPTION: 480Y/277V, 3PH 1 I 0 I DIVCON 'CONTROLS I E I pi 0I I I I EXISTING PEAK UTILITY LOAD 0 0.9 pf N/A 1 25% 1 1 I 100% 97.44 LIGHTING (PER NEC -220) NO BOTTOM ENTRY 125% NO BOTTOM ENTRY UPS o 35.89 I 1 1 I CA o KITCHEN EQUIPMENT I 1 I L1 SEC 1 SECTION NUMBER SECTION WIDTH SHIPPING SECTIONS 3 TOP VIEW 1 36.00 56.00 - 2 -20.00 off 36.00 36.00 5 20.00 -- 26.00 46.00 FRONT ELEVATION EATON/CUTLER HAMMER IFS INTERGRATED SWITCHGEAR NO SCALE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL CONNECTIONS TO THE INTEGRATED SWITCHGEAR WITH TYLER WALKER OF WR CONTROLS (PHONE 614-934-6416). ONE -LINE DIAGRAM LEGEND: NEW EQUIPMENT EXISTING EQUIPMENT EQUIPMENT TO BE DEMOLISHED x F3 SWITCH3OA SW3D '2A' (5 SETS) OF 4-600KCMIL, (1) 250KCMIL GND. IN 4" CONDUIT LANDLORD'S ELEC. ROOM - SECOND FLOOR (ZONE A) AFC = 65,000A 13 2000 AMPS 480Y/277V 30 4W 65,000A AIC 11 11 X800 IIP "1800 FNERSM-RA' III L_L1 1 1000 3P 1000 FRS -R NEMA1 6 2 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 17 200 3P 200 FRS -R NEMA1 C.T. AND METER (EXISTING TO BE REMOVED) 0 0 \ \I 3 PO 1800 NEMA1 I- 1_1 L - - H C.T. AND METER (NEW) H I I I H PTIVECL_OCK b H V D 3 VAI\ WC t� t1t1 1 = RECEIVING #115 ROOM P II H PP 0 L---� -----E 1 -- EXISTING BORDER'S INTEGRATED SWITCH GEAR TO BE REMOVED LC 0 0 LB TXL1 112.5 KVA XFMR PRI: 480V 3PH 3W --F SEC: 120/208V 3PH 4W e - me - = 4 Deme Theme �4=e T 4 me S =1 4 m e m e Th G m e m e Th Th e m e Theme H Th e =4 = - =e m =e m4 Th - me m - �T_=a e me m =6 =21 CC = Them 4 = = L m"e m = C m e = Theorem CA 0 L V 3P ELEC ROOM AFC = 65,000A TCS ELECTRICAL ROOM(NEW) n H u 7- FURNISHED BY WESCO W.R. CONTROLS AND INSTALLED BY ELECTRICAL CONTRACTOR (REFER TO 2/E-6.0) EBJ I MBJ SWITCH3OAD SW3D '452A23 LANDLORD'S MAIN ELEC. ROOM - FIRST FLOOR (ZONE A) AFC = 65,000A NEUTRAL BUS GROUND BUS • • MAIN - 3000A GFI RELAY 7 3000A • GFI RELAY 2000AT 3P GFI RELAY 2000AF FRS -R NEMA1 2000AT 3P 2000AF FRS -R NEMA1 I-131 3000 AMPS 480Y/277V 30 4W 65,000A AIC AIC x Ld TO GROUND BAR AT MAIN T TELEPHONE BOARD (TTB) TO STRUCTURAL STEEL TO ABOVE GROUND METAL PIPING TO WATER SERVICE x LL X w >< w x w TO BUILDING FOOTING (USER) TO GROUND ROD(S) I I 45KVA XFMR) (EXISTING TO REMAIN J ) x w F2 L_ 1000 AMPS 480Y/277V 30 4W 65,000A AIC 11225 2(150 \ 3P \ 3P 125 3P 50 1P 25 3P 50 3P 50 3P 50 3P 50 3P 0 20 3P 1 25 3P 10 2 80 \ 3P 131 ( 40 3P 9 4- ( I 40 3P 15 60 3P IPI ELECTRICAL ONE -LINE & RISER CI 800A SWITCH 3P RATING AS SHOWN 200A AM P FRS FUSED SWITCH RATING AND FUSE TYPE AS SHOWN 225A CIRCUIT BREAKER 3P RATINGS AS SHOWN, 3 POLE, UNO TX# TRANSFORMER TYPE AND RATINGS AS SHOWN FDR? UTILITY METER GFR WH D 15 -3� TVSS -III -o oHil =X DIGITAL DD FEEDER IDENTIFICATION REFER TO FEEDER SCHEDULE 400A DRAWOUT CIRCUIT 3P BREAKER. RATINGS AS SHOWN, 3 POLE, UNO 200A COMBINATION FUSED AMPS SWITCH/STARTER FRS NEMA 1 225A COMBINATION CIRCUIT 3P BREAKER/STARTER NEMA 1 COMBINATION DIGITAL VOLT METER/ AMMETER GROUND FAULT RELAY KIRK -KEY INTERLOCK SHUNT TRIP AMMETER, RANGE AS SPECIFIED OR REQUIRED AMMETER SWITCH VOLTMETER SWITCH VOLTMETER, RANGE AS SPECIFIED OR REQUIRED UTILITY METER (AS REQUIRED BY UTILITY) WATT-HOUR METER "D" DENOTES DEMAND REGISTER, "15" DENOTES MINUTES OF DEMAND INTERVAL CURRENT TRANSFORMER RATING AS SPECIFIED OR REQUIRED POTENTIAL TRANSFORMER RATING AS SPECIFIED OR REQUIRED TRANSIENT VOLTAGE SURGE SUPPRESSOR GROUND CONNECTION GROUND CONNECTION WITH TEST WELL GROUND ROD LIGHTNING ARRESTER CONTACT (OPEN OR CLOSED) N F PNLBD H1 F6 TXCA 30kVA ,y+,,rt 480V /X F7 208Y/120V 0 x F8 PNLBD CA 0 0 C: N • 60A 2P N CO x T9 x F10 TXL1 75kVA I rrevn 480V Fl 208Y/120V1 ! 0 0 M x F12 UPS TO BUILDING GROUNDING ELECTRODES. 1T13 PNLBD UPS ALL ITEMS WITHIN ARE INTEGRAL TO THE OWNER FURNISHED, CONTRACTOR INSTALLED, INTEGRATED FACILITY SYSTEM. PLEASE CONTACT TYLER WALKER AT 614-934-6416 WITH ANY TECHNICAL QUESTIONS. J 0 -J z 0 ONE -LINE DIAGRAM NO SCALE x T14 z coo- zW I� 0> z 0 0 xT15 TX tA.w 0 0 CD 60 3P 50 FRS -R NEMA3R (NEW) ACV RTU -1 15kVA 480V 208Y/120V T16 60 3P 50 FRS -R NEMA3R (NEW) T19 M 60 3P 50 FRS -R NEMA3R (NEW) g 0. 60 3P 50 FRS -R NEMA3R (NEW) T21 8 30 3P 20 FRS -R NEMA3R (NEW) x T22 30 3P 25 FRS -R NEMA3R (NEW) T23 /0/ /0/ /0/ /0/ /0/ RTU -2 EP ELEV. MECH. ROOM RTU -3 60 AMPS 208Y/1 20V 30 4W 10,000A AIC 60 1; 20 ®50 ®20 >< W T17 0 w J CONTROLS (EXISTING TO REMAIN) RTU -4 RTU -5 RTU -6 100 3P 80 FRS -R 5 / -- T24 ELEV. CONTROL PANEL 60 3P 40 ESCALATOR �/ ELEV. #PE -1 ' �J (EXISTING TO REMAIN) 60 3P 40 x T26 OG OG ESCALATOR 0 z I= U) W (7 SETS) OF 4-#750KCMIL IN 5" CONDUIT 33,900 x I Fl PAD MOUNTED UTILITY TRANSFORMER (EXISTING) AIC RATING ON SECONDARY SIDE OF UTILITY TRANSFOMRER IS 33,900. INFORMATION PROVIDED FROM SPARKLING ENGINEERING/TECHNICAL SERVICES FROM PERMIT/BID DOCUMENTS DATED 02/05/2007, SHEET E7.2-1. TENANT ELECTRICAL SERVICE LOAD SUMMARY TENANT OCCUPANCY TYPE: M TENANT SQUARE FOOTAGE: 22,000 SERVICE DESCRIPTION: 480Y/277V, 3PH 1 I 0 I DIVCON 'CONTROLS I E I pi 0I I I I EXISTING PEAK UTILITY LOAD 0 0.9 pf N/A 1 25% 1 1 I 100% 97.44 LIGHTING (PER NEC -220) 66.00 125% I I I I UPS o 35.89 I 1 1 I CA o KITCHEN EQUIPMENT I 1 I L1 SEC 1 0.00 L1 oSEC 2 25.60 SPD/TVSS MDP TCSWR****.A01 LARGEST MOTOR LOAD 0.00 125% I- h -I- TXL1 75 KVA XFMR IPRI: 480V 3PH 3W SEC: 120/208V 3PH 4W I 14.00 FD3050 4.80 125% H1 O SHOW WINDOW / TRACK LIGHTING 17.10 TXC 1 30 KVA XFMR PRI: 480V 3PH 3W I SEC: 120/208V 3PH 4W I®®®®® 1=========== ®®®=® oo®=® ®®® ®o® 6.92 ®=== 16========g1== ®®® I ®®® ®®®®® TOTAL LOAD I ®®® KVA 16========== ®®®®® TOTAL AMPACITY 407.18 AMPS 337.26 SERVICE AMPACITY ®®® I AMPS 1000.00 SPARE CAPACITY ®®®=ate I I 663 1 36.00 56.00 - 2 -20.00 off 36.00 36.00 5 20.00 -- 26.00 46.00 FRONT ELEVATION EATON/CUTLER HAMMER IFS INTERGRATED SWITCHGEAR NO SCALE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL CONNECTIONS TO THE INTEGRATED SWITCHGEAR WITH TYLER WALKER OF WR CONTROLS (PHONE 614-934-6416). ONE -LINE DIAGRAM LEGEND: NEW EQUIPMENT EXISTING EQUIPMENT EQUIPMENT TO BE DEMOLISHED x F3 SWITCH3OA SW3D '2A' (5 SETS) OF 4-600KCMIL, (1) 250KCMIL GND. IN 4" CONDUIT LANDLORD'S ELEC. ROOM - SECOND FLOOR (ZONE A) AFC = 65,000A 13 2000 AMPS 480Y/277V 30 4W 65,000A AIC 11 11 X800 IIP "1800 FNERSM-RA' III L_L1 1 1000 3P 1000 FRS -R NEMA1 6 2 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 200 3P 200 FRS -R NEMA1 17 200 3P 200 FRS -R NEMA1 C.T. AND METER (EXISTING TO BE REMOVED) 0 0 \ \I 3 PO 1800 NEMA1 I- 1_1 L - - H C.T. AND METER (NEW) H I I I H PTIVECL_OCK b H V D 3 VAI\ WC t� t1t1 1 = RECEIVING #115 ROOM P II H PP 0 L---� -----E 1 -- EXISTING BORDER'S INTEGRATED SWITCH GEAR TO BE REMOVED LC 0 0 LB TXL1 112.5 KVA XFMR PRI: 480V 3PH 3W --F SEC: 120/208V 3PH 4W e - me - = 4 Deme Theme �4=e T 4 me S =1 4 m e m e Th G m e m e Th Th e m e Theme H Th e =4 = - =e m =e m4 Th - me m - �T_=a e me m =6 =21 CC = Them 4 = = L m"e m = C m e = Theorem CA 0 L V 3P ELEC ROOM AFC = 65,000A TCS ELECTRICAL ROOM(NEW) n H u 7- FURNISHED BY WESCO W.R. CONTROLS AND INSTALLED BY ELECTRICAL CONTRACTOR (REFER TO 2/E-6.0) EBJ I MBJ SWITCH3OAD SW3D '452A23 LANDLORD'S MAIN ELEC. ROOM - FIRST FLOOR (ZONE A) AFC = 65,000A NEUTRAL BUS GROUND BUS • • MAIN - 3000A GFI RELAY 7 3000A • GFI RELAY 2000AT 3P GFI RELAY 2000AF FRS -R NEMA1 2000AT 3P 2000AF FRS -R NEMA1 I-131 3000 AMPS 480Y/277V 30 4W 65,000A AIC AIC x Ld TO GROUND BAR AT MAIN T TELEPHONE BOARD (TTB) TO STRUCTURAL STEEL TO ABOVE GROUND METAL PIPING TO WATER SERVICE x LL X w >< w x w TO BUILDING FOOTING (USER) TO GROUND ROD(S) I I 45KVA XFMR) (EXISTING TO REMAIN J ) x w F2 L_ 1000 AMPS 480Y/277V 30 4W 65,000A AIC 11225 2(150 \ 3P \ 3P 125 3P 50 1P 25 3P 50 3P 50 3P 50 3P 50 3P 0 20 3P 1 25 3P 10 2 80 \ 3P 131 ( 40 3P 9 4- ( I 40 3P 15 60 3P IPI ELECTRICAL ONE -LINE & RISER CI 800A SWITCH 3P RATING AS SHOWN 200A AM P FRS FUSED SWITCH RATING AND FUSE TYPE AS SHOWN 225A CIRCUIT BREAKER 3P RATINGS AS SHOWN, 3 POLE, UNO TX# TRANSFORMER TYPE AND RATINGS AS SHOWN FDR? UTILITY METER GFR WH D 15 -3� TVSS -III -o oHil =X DIGITAL DD FEEDER IDENTIFICATION REFER TO FEEDER SCHEDULE 400A DRAWOUT CIRCUIT 3P BREAKER. RATINGS AS SHOWN, 3 POLE, UNO 200A COMBINATION FUSED AMPS SWITCH/STARTER FRS NEMA 1 225A COMBINATION CIRCUIT 3P BREAKER/STARTER NEMA 1 COMBINATION DIGITAL VOLT METER/ AMMETER GROUND FAULT RELAY KIRK -KEY INTERLOCK SHUNT TRIP AMMETER, RANGE AS SPECIFIED OR REQUIRED AMMETER SWITCH VOLTMETER SWITCH VOLTMETER, RANGE AS SPECIFIED OR REQUIRED UTILITY METER (AS REQUIRED BY UTILITY) WATT-HOUR METER "D" DENOTES DEMAND REGISTER, "15" DENOTES MINUTES OF DEMAND INTERVAL CURRENT TRANSFORMER RATING AS SPECIFIED OR REQUIRED POTENTIAL TRANSFORMER RATING AS SPECIFIED OR REQUIRED TRANSIENT VOLTAGE SURGE SUPPRESSOR GROUND CONNECTION GROUND CONNECTION WITH TEST WELL GROUND ROD LIGHTNING ARRESTER CONTACT (OPEN OR CLOSED) N F PNLBD H1 F6 TXCA 30kVA ,y+,,rt 480V /X F7 208Y/120V 0 x F8 PNLBD CA 0 0 C: N • 60A 2P N CO x T9 x F10 TXL1 75kVA I rrevn 480V Fl 208Y/120V1 ! 0 0 M x F12 UPS TO BUILDING GROUNDING ELECTRODES. 1T13 PNLBD UPS ALL ITEMS WITHIN ARE INTEGRAL TO THE OWNER FURNISHED, CONTRACTOR INSTALLED, INTEGRATED FACILITY SYSTEM. PLEASE CONTACT TYLER WALKER AT 614-934-6416 WITH ANY TECHNICAL QUESTIONS. J 0 -J z 0 ONE -LINE DIAGRAM NO SCALE x T14 z coo- zW I� 0> z 0 0 xT15 TX tA.w 0 0 CD 60 3P 50 FRS -R NEMA3R (NEW) ACV RTU -1 15kVA 480V 208Y/120V T16 60 3P 50 FRS -R NEMA3R (NEW) T19 M 60 3P 50 FRS -R NEMA3R (NEW) g 0. 60 3P 50 FRS -R NEMA3R (NEW) T21 8 30 3P 20 FRS -R NEMA3R (NEW) x T22 30 3P 25 FRS -R NEMA3R (NEW) T23 /0/ /0/ /0/ /0/ /0/ RTU -2 EP ELEV. MECH. ROOM RTU -3 60 AMPS 208Y/1 20V 30 4W 10,000A AIC 60 1; 20 ®50 ®20 >< W T17 0 w J CONTROLS (EXISTING TO REMAIN) RTU -4 RTU -5 RTU -6 100 3P 80 FRS -R 5 / -- T24 ELEV. CONTROL PANEL 60 3P 40 ESCALATOR �/ ELEV. #PE -1 ' �J (EXISTING TO REMAIN) 60 3P 40 x T26 OG OG ESCALATOR 0 z I= U) W (7 SETS) OF 4-#750KCMIL IN 5" CONDUIT 33,900 x I Fl PAD MOUNTED UTILITY TRANSFORMER (EXISTING) AIC RATING ON SECONDARY SIDE OF UTILITY TRANSFOMRER IS 33,900. INFORMATION PROVIDED FROM SPARKLING ENGINEERING/TECHNICAL SERVICES FROM PERMIT/BID DOCUMENTS DATED 02/05/2007, SHEET E7.2-1. TENANT ELECTRICAL SERVICE LOAD SUMMARY TENANT OCCUPANCY TYPE: M TENANT SQUARE FOOTAGE: 22,000 SERVICE DESCRIPTION: 480Y/277V, 3PH LOAD DESCRIPTION Connected KVA Demand FACTOR Demand KVA EXISTING PEAK UTILITY LOAD 0 0.9 pf N/A 1 25% 0.00 HVAC - SUMMER 97.44 100% 97.44 LIGHTING (PER NEC -220) 66.00 125% 82.50 RECEPTACLES 35.89 1 00%;50% 22.95 KITCHEN EQUIPMENT 0.00 100% 0.00 MOTOR LOADS 25.60 100% 25.60 LARGEST MOTOR LOAD 0.00 125% 0.00 SUPPLEMENTAL ELECTRIC HEAT 14.00 100% 14.00 DISPLAY CASE/SIGNAGE 4.80 125% 6.00 SHOW WINDOW / TRACK LIGHTING 17.10 PER NEC 21.38 EXTERIOR LIGHTING 5.53 125% 6.92 EXISTING LOAD TO BE DELETED 0.00 100% 0.00 TOTAL LOAD 338.53 KVA 280.39 TOTAL AMPACITY 407.18 AMPS 337.26 SERVICE AMPACITY 1000 AMPS 1000.00 SPARE CAPACITY 0.95 AMPS 663 ONE LINE DIAGRAM NOTES: 2 3 UPS NOTES: 1. EATON 9170 MODEL (3) 3kVA/2.5kW SPLIT PHASE POWER MODULES AND PW9170 + 12 SLOT RACK WITH 6 -SLOT BATTERY CABINET & 20AMP CHARGE MODULE, 55 MINUTES OF BATTERY BACK-UP TIME. UL 1778 RATED. 208 VOLT/SINGLE PHASE INPUT (2 WIRE, PLUS GROUND). 208/120 VOLT SINGLE PHASE, 3 WIRE PLUS GROUND OUTPUT. 2. SYSTEM SHALL INCLUDE: A. DOUBLE -CONVERSION ONLINE TECHNOLOGY B. HARDWIRED INPUT C. LCD DISPLAY D. INPUT/OUTPUIT NOISE SUPPRESSION AND ISOLATION FRAME E. MAIN INPUT BREAKER F. BATTERY REPLACEMENT - HOT SWAPPABLE G. 4 HOUR BATTERY RECHARGE TIME H. EXPANDABLE BY INSTALLING ADDITION POWER MODULES AND BATTERY CHARGES I. LOW VOLTAGE DISTORTION OUTPUT INVERTER J. AUTOMATIC BATTERY CHARGER K. SNMP CAPABILITY-WEB/SNMP ENABLED CARD OPTIONS - RS -232 (DB -9) L. IS-WEBCARD - INTERFACES CARD DELIVERS SNMP - COMMUNICATING WITH OWNERS SERVER. M. STANDARD TWO-YEAR LIMITED WARRANTY(PARTS AND LABOR). N. UPS BYPASS 0. SURGE SUPPRESSION - IEEE/ANSI C62.41 3. ACCEPTABLE MANUFACTURER: EATON 4. G.C. TO PROVIDE COMMISSIONING OF NEW INVERTER PRIOR TO PUNCH LIST 5. ONSITE START UP BY AUTHORIZED EATON PRODUCT REPRESENTATIVE. 6. THIS EQUIPMENT SUPPLIED BY OWNER AND INSTALLED UNDER THIS WORK. INSTALL LIGHTING INVERTER FURNISHED BY OWNER. 8.0KW, 277V INPUT, 277V OUTPUT. REFER TO INVERTER NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION. DIVCON PANEL SHALL BE INSTALLED IN INTEGRATED FACILITY SYSTEM IN FACTORY. PROVIDE DATA OUTLET FOR DIVCON PANEL, REFER TO 2/E-6.0. COORDINATE INSTALLATION WITH TCS PROJECT MANAGER, IFS MANUFACTURER, AND DIVCON PROJECT MANAGER PRIOR TO ROUGH -IN. PROVIDE AND INSTALL NEW 1000A-3P-1000AF, NEMA 1 FUSED SWITCH TO BE INSTALLED IN LANDLORD'S EXISTING 2000 AMP MAIN SWITCHBOARD - SWBD '2A'. INSTALL UPS FURNISHED BY OWNER. REFER TO UPS NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION. 5 INVERTER NOTES: 1. LINE -INTERACTIVE PWM/IGBT TECHNOLOGY UNITERRUPTIBLE POWER SYSTEM, SHALL BE SINGLE PHASE, 8kWA/8kW WITH 277V INPUT. MYERS POWER PRODUCTS, INC. EMERGENCY LIGHTING INVERTER MODEL #E -7-S88. MINIMUM 90 MINUTES OF BATTERY BACKUP AT FULL LOAD. 2. SYSTEM SHALL INCLUDE: A. MICRO -PROCESSOR CONTROL B. HARDWIRED INPUT C. UL 924 LISTED E. NO BREAK, SEAMLESS TRANSFER F. SINEWAVE OUTPUT G. INPUT BREAKER H. SINGLE CABINET FOR BATTERIES AND INVERTER I. AUTOMATIC EVENT, TEST AND ALARM LOG J. 1 YEAR STANDARD WARRENTY INCLUDING PARTS AND LABOR. K. SEALED, MAINTENANCE FREE, 15 YEAR BATTERY PRO -RATED BATTERY WARRANTY L. AUTOMATIC BATTERY CHARGER M. UNIT MOUNTED DISTRIBUTION INCLUDING (8) 277VAC, 20A, SINGLE POLE CIRCUIT BREAKERS. N. MODULAR DESIGN 0. SYSTEM MONITORING TERMINALS (SMT) P. SNMP CARD FOR COMMUNICATING (RS232 COMMUNICATIONS PORT). R. LOW AUDIBLE NOISE 3• ACCEPTABLE MANUFACTURER: CONTROLLED POWER COMPANY (7.5KW) 4. UNIT SHALL FIT IN SPACE ALLOTED. 5, G.C. TO PROVIDE COMMISSIONING OF NEW INVERTER PRIOR TO PUNCH LIST 6. THIS EQUIPMENT SUPPLIED BY OWNER AND INSTALLED UNDER THIS WORK. EXISTING 'POWER MODULE' SWITCH PS2 WITH CLASS J FUSES NOT INCLUDED, FIRE SAFETY INTERFACE RELAY (3PDT. 10 AMP. 120V) AND MECHANICAL INTERLOCK AUXILLARY CONTACT FOR HYDRAULIC ELEVATORS WITH AUTOMATIC RECALL F61 NEW CT CABINET AND METER. ❑7 EXTEND AND CONNECT (4) #400KCMIL, (1) 2/0 G. IN (3) SETS OF 4" EXISTING CONDUITS FROM EXISTING 'SWBD' '2A' TO NEW POWER WALL(IFS) LOCATED IN NEW SECOND FLOOR ELECTRICAL #112 REFER TO SHEET E-5.1 FOR MORE INFORMATION. 8 9 10 11 12 13 DISCONNECT SWITCHES PROVIDED BY (DIVISION 1 6) ELECTRICAL CONTRACTOR. RELOCATE (2) 40 AMP CIRCUIT BREAKER FROM EXISTING TO BE REMOVED PANEL 'MDP', CIRCUIT #5 AND #6. RELOCATE (1) 80 AMP CIRCUIT BREAKER FROM EXISTING TO BE REMOVED PANEL 'MDP', CIRCUIT #7. CONTRACTOR SHALL REMOVE EXISITNG 800 AMP SWITCH SERVING PREVIOUS TENANT AND REPLACE WITH NEW 1000 AMP SWITCH IN EXISTING SWITCHBOARD SWBD '2A'. CONTRACTOR SHALL MAKE ALL FINAL CONNECTION. CONTRACTOR SHALL REPLACE EXISTING PANEL 'LC' WITH NEW PANEL 'EP'. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF EXISTING PANEL 'LC' PRIOR TO BID. REFER TO SHEET E5.0, DETAIL 7 FOR ENLARGED PLAN OF FIRST FLOOR ELEVATOR ROOM AND ELEVATOR. LANDLORD SHALL VERIFY CAPACITY OF EXISTING SWITCHBOARD TO SERVE EXISTING AND NEW LOADS. CIRCUIT SCHEDULE: ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN/THWN-2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFlCATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C. MODIFY SIZES ACCORDING TO NFPA 70. 23 I 33 I 52 53 62 64 123 L 224 1004 EX G100 G150 G300 L T224 T54 T55 T62 T63 T63IG 20A, (3)#12, (1)#12G, 1/2" C 30A, (3)#10, (1)#1OG, 1/2" C 50A, (2)#8, (1)# 1 OG, 1 /2" C 50A, (3)#8, (1)#1 OG, 3/4" C 60A, (2)#6, (1)#1OG, 1" C 60A, (4)#6, (1)#10G, 1" C 125A, (3)#1, (1)#6G, 1-1/2" C 225A, (4)#4/0, (1)#4G, 2-1/2" C 1000A, (3) 3" C, EACH W/ (4)-400kcmil, (1)#2/OG EXISTING CONDUCTORS AND CONDUIT TO REMAIN GND, #8 COPPER GROUND, 3/4" C GND, #6 COPPER GROUND, 3/4" C GND, #2 COPPER GROUND, 3/4" C 225A, (4)#4/0, (1)#2G, 2-1/2" C 50A, (4)#6, (1)#8G, 1" C 50A, (4)#6, (1)#8G, (1)#8 IG, 1" C 60A, (2)#6, (1)#8G, 1" C 60A, (3)#6, (1)#8G, 1" C COMM GND, (3)#6, (1)#8G, (1)#8IG, COPPER GROUND, IN 1" C L(3O4,7 REVIEANCD E FOR TH �70_NEC JUL 2 2 2013 -"Ma Tukwila BUILDING DIVISION Short -Circuit and Voltage Drop Calculations v2.09.02 Distances are for calculation purposes only and shall not be used for contractor The following calculations are based on the 'Point -by -Point" method where: ISC (2) = ISC(1) x M(1) M= 1/(1+f) Feed91:(30) = ISC (1) = short circuit current at fault point 1 ISC (2) = short circuit current at fault point 2 Feeder' (10)= L = Length C = "C" Factor Feeder Types = NM - Non Magnetic Conduit, M - Magnetic Conduit, FB - Feeder Busway, PB takeoffs nor bidding 1.732 x L x lae - Contractor shall XFMR: f (30) = XFMR: f (10)= volts "C" = 1 / impedance notify Engineer of any field IP(aca)x Vp x 1.73 x %Z condition that results in a change of 10% or greater circuit distance IS(sca)= Vp x M x IP(aca) VOLTAGE DROP (30): Vs %VD= ((R x cos(arocos(pf)) + X x sin (arocos(pf))) x L/# x I x 1.73) / E VOLTAGE DROP (10): %VD= ((R x cos(arcoos(pf)) + X x sin(ar000s(pf))) x 2 x L/# x I) / E IP = Primary short circuit current %VD CUM= Cumulative Voltage Drop from Fault Point 1 to Fault Point # Vp = Primary voltage R= resistance in ohms per LF IS= Secondary short circuit current X= reactances in ohms per LF Vs= Secondary voltage C x E 2 x L x lie E = Line to line table where Busway, TX - Transformer 100.000 x KVA IP(aca)x Vp x %Z 100.000 x KVA per linear foot C x E of circuit from Bussman - Plug-in Fault Point (F#) Bus/Feeder Description Phase Source (Fault Point) Source Isc (amps) Feeder Conductor 'C' value Busway C value L -L Volts E Circuit Length L Load Power Factor(pf) Circuit Load A Conductor Conductor Impedence, Z/ 0 Transformer f M FAULT CURRENT Isc VOLTAGE DROP %VD TOTAL V.D. %VD CUM Fault Point (F#) Conduit Type Material CU or AL # Wire/Bus Size Resistance R Reactance X Type kVA Degree Rise Z V sec 1 Utility Service Point 33900 at the secondary of the utility transformer 480Y/277V - 3 phase Source Isc + 6X Motor Contribution = 33900 1 Motor Contribution The connected full load motor amps (includes compressors) on the system 2 Switchboard 4S2A2B 3 33900 33900 NM CU 7 Set(s) of 750 kcmil 29735 480 110 0.95 2400 0.000019 0.000038 0.317560 0.065 0.94 31842 0.41% 0.41% 2 3 Switchboard 2A 3 2 31842 M CU 5 Set(s) of 600 kcmil 22965 480 74 0.95 1600 0.000025 0.000048 0.317560 0.074 0.93 29646 0.33% 0.74% 3 4 MDP 3 3 29646 M CU 3 Set(s) of 400 kcmil 20566 480 65 0.95 472 0.000035 0.000049 0.317560 0.113 0.90 26644 0.18% 0.92% 4 5 Panel H1 3 4 26644 M CU 1 Set(s) of 4/0 AWG 15082 480 10 0.95 49 0.000063 0.000051 0.317560 0.064 0.94 25047 0.01% 0.93% 5 6 TXCA - PRIMARY 3 4 26644 M CU 1 Set(s) of 6 AWG 2425 480 6 0.95 36 0.000490 0.000064 0.317560 0.238 0.81 21524 0.04% 0.96% 6 7 TXCA - SECONDARY 3 6 21524 TX 480 TP -1 30 115 4 208 23.858 0.04 1998 0.96% 7 8 Panel CA 3 7 1998 M CU 1 Set(s) of 6 AWG 2425 208 4 0.95 36 0.000490 0.000064 0.317560 0.027 0.97 1945 0.06% 1.01% 8 9 UPS 1 8 1945 M CU 1 Set(s) of 6 AWG 2425 208 10 0.95 30 0.000490 0.000064 0.317560 0.077 0.93 1806 0.14% 1.15% 9 10 TXL1 - PRIMARY 3 4 26644 M CU 1 Set(s) of 1 AWG 7293 480 4 0.95 171 0.000160 0.000057 0.317560 0.053 0.95 25309 0.04% 0.96% 10 11 TXL1 - SECONDARY 3 10 25309 TX 480 TP -1 75 115 3.3 208 9.258 0.10 5694 0.96% 11 12 PANEL L1 3 11 5694 M CU 1 Set(s) of 4/0 AWG 15082 208 4 0.95 171 0.000063 0.000051 0.317560 0.013 0.99 5623 0.04% 1.00% 12 13 UPS PANEL 1 9 1806 M CU 1 Set(s) of 6 AWG 2425 208 10 0.95 30 0.000490 0.000064 0.317560 0.072 0.93 1685 0.14% 1.29% 13 14 INVERTER 1 4 26644 M CU 1 Set(s) of 8 AWG 1557 277 10 0.95 11 0.000780 0.000065 0.317560 1.236 0.45 11918 0.06% 0.98% 14 15 TXEP - PRIMARY 3 4 26644 M CU 1 Set(s) of 10 AWG 981 480 8 0.95 14 0.001200 0.000063 0.317560 0.784 0.56 14934 0.05% 0.96% 15 16 TXEP - SECONDARY 3 15 14934 TX 480 TP -1 15 80 2.5 208 20.693 0.05 1589 0.96% 16 17 ELEV. CONTROLLER 3 16 1589 M CU 1 Set(s) of 12 AWG 617 208 8 0.95 14 0.002000 0.000068 0.317560 0.172 0.85 1356 0.18% 1.14% 17 18 RTU#1 3 4 26644 M CU 1 Set(s) of 8 AWG 1557 480 87 0.95 36 0.000780 0.000065 0.317560 5.372 0.16 4181 0.86% 1.78% 18 19 RTU#2 3 4 26644 M CU 1 Set(s) of 8 AWG 1557 480 42 0.95 36 0.000780 0.000065 0.317560 2.593 0.28 7415 0.42% 1.33% 19 20 RTU#3 3 4 26644 M CU 1 Set(s) of 8 AWG 1557 480 51 0.95 36 0.000780 0.000065 0.317560 3.149 0.24 6421 0.50% 1.42% 20 21 RTU#4 3 4 26644 M CU 1 Set(s) of 8 AWG 1557 480 58 0.95 36 0.000780 0.000065 0.317560 3.581 0.22 5816 0.57% 1.49% 21 22 RTU#5 3 4 26644 M CU 1 Set(s) of 12 AWG 617 480 38 0.95 14 0.002000 0.000068 0.317560 5.921 0.14 3850 0.37% 1.29% 22 23 RTU#6 3 4 26644 M CU 1 Set(s) of 10 AWG 981 480 56 0.97 16.7 0.001200 0.000063 0.245566 5.488 0.15 4106 0.40% 1.32% 23 24 Pass. Elevator PE -1 3 4 26644 M CU 1 Set(s) of 4 AWG 3806 480 102 0.95 40 0.000310 0.000060 0.317560 2.577 0.28 7449 0.46% 1.38% 24 25 Escalator #1 3 4 26644 M CU 1 Set(s) of 8 AWG 1557 480 75 0.95 27.6 0.000780 0.000065 0.317560 4.631 0.18 4731 0.57% 1.49% 25 26 Escalator #2 3 4 26644 M AL 1 Set(s) of 8 AWG 951 480 79 0.95 27.6 0.001300 0.000065 0.317560 7.987 0.11 2965 0.99% 1.90% 26 p+9 RECEIVED CITY OF TUKWiLA JUN 282013 PERMIT CENTER g LJ - Co j LO LO 8 co co "" N N O :2 5 N N To © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM c I- co J co LLJQ co Q °- w z U W U J Z I-- ZO0H UJ ~ CO n 0 0 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS TG Drawn TG Checked TG Approved ELECTRICAL RISER DIAGRAM AND SWITCHGEAR DETAILS Project No. 13007.00 Date Last PERMIT - 06.24.13 Revision E-6.0 Z1 Z1 Z1 Z1 Z4 Z4 Z5 Z3 Z3 Z3 Z5 Z PANELBOARD: H1 (NEW) FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: SERIES RATED MAIN SIZE/TYPE: MLO SERVES: THE CONTAINER STORE VOLTS/PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM, ROOM #:112 CKT NO. DESCRIPTION VOLTAMPS/PHASE WIRE BKR AMP P P BKR AMP WIRE�VOLTAMPS/PHASE NO. A B C DESCRIPTION CKT NO. A B C NO. 1 LTG - WEST SALES #1(A FIXTURES) 1,910 / // C 12 20 1 1 20 10 20 /����/ j SPARE 2 3 LTG - WEST SALES #2(A FIXTURES) / 2,758 � 12 20 1 1 20 1 ��/�/ 20 / SPARE 4 5 LTG - EAST SALES #1(A FIXTURES) / 2,195 12 20 1 1 20 20 7// / 600 RCPT - BREAK RM - FLAT S. TV 6 SPARE 6 7 LTG - EAST SALES #2(A FIXTURES) 1,317 ///// r��� / 12 20 1 1 20/ 360 �f��� DIVCON PANELS (ELEC. RM) 8 9 �� SPARE 8 9 SIGNAGE (SOUTH ENTRY DOOR) // / 1,200 //- 12 20 1 1 20 11 �� 1 f/J / / %�/ SPARE 10 11 SIGNAGE (NORTH ENTRY DOOR) /// /ji,2OO 20 12 20 1 1 20 720 / ��/ j//// 12 SPARE 12 13 LTG- BACK OF HOUSE 2,466 12 1,260 / 12 20 1 1 20 �/ 17 20 �/ SPARE 14 15 LTG - N.E. PERIMTER (M) /7/ 2,475 17 12 20 1 1 20 20 1 1 20 SPARE 16 17 LTG - SALES FLOOR GEN (E) /////%f/1300 RCPT - SHOW WINDOW 5 360/7 12 20 1 1 20 1 20 / / jj SPARE 18 19 LTG ENTRY C6A THROUGH C6H 448 %/ / 12 20 1 1 20 10 / / / 1,260 /////// ` SPARE 20 21 LTG - FRONT OF STORE(G9) / 705 �// 12 20 1 1 20 12 / ��/ 3,989 600 WATER HEATER WH -1 22 23 SPARE �// 1 1 20 20 1 1 40 8 360 12 20 r 8,003 INSTA-HOT (DUAL ELEMENT #1) 24 25 LTG - G7 FIXTURES 600f 20 7 23 20 1 1 40 8 8,003 / / �/ INSTA-HOT (DUAL ELEMENT #2) 26 27 SPARE SPARE�j20 � 31 SPARE 1 1 20 12 / 1,720 1 OH DOOR #1 28 29 SPACE/ �� / SPARE � 12 1 1 20 1 1 //,/ 12 �� jf/ SPACE 30 31 SPACE j/��// �j/ 540 12 1 1 1 20 1 % / 7 �/ SPACE 32 33 SPACE �� 0 /� 20 1 1 1 1 1 1 20 �/ 39 AUTOMATIC DR (FRNT ENTRY) 2 SPACE SPACE 34 36 35 SPACE// 20 1 1 37 SPACE �1 RECEPT - BREAK RM - COFFEE M. 40 41 SPARE �/ 1 LOAD CONN. VA 20 / 1 SPACE 38 39 SPACE SECTION: 2 j // LTG - S.W. PERIMETER(G5) 1,150 1 1 12 20 / 1 20 SPACE 40 41 SPACE / //// 44 45 LTG - 3.W. PERIMETER(G6) 1 1 �/ j// 12 20 / / 1 SPACE 42 I SUBTOTAL 6,741 7,138 4,695 LTG - CENTER AISLE SALES (G5) 8,003 5,709 8,003 SUBTOTAL CONN. VA DF 12 TOTAL PHASE A - VA 14,744 LOAD CONN. VA DF 1.00 LOAD AMPS 53 COOLING 49 1.00 1,100 REFRIGERATION /2 //�/ 1.00 TOTAL PHASE B - VA 12,847 HEATING 20 0 1,350 SIGN/DISPLAY f 1.25 AMPS 46 LIGHTING 18,574 1.25 KITCHEN 20 1.00 TOTAL PHASE C - VA 12,698 RECEPTACLES 0� / 1.0/.5 EXISTING 52 1.00 AMPS 46 MOTORS 1,720 1.00 20 LARGE MOTOR 1 1.25 TOTAL DEMAND j/ TOTAL PNLBD - VA 40,289 SUPP HEAT 16,006 1.00 SPARE SHOW WINDOW %/// 1.25 44,933 VA 20 AMPS 48 MISC EQUIP 3,989 1.00 LTG TRACK SPARE 1.00 54 A LTG - N.W. SALES - CASH WRAP (Cr PANELBOARD NOTES Z# - SMART CIRCUIT BREAKER POINT OF CONTROL LTG TRACK - TRACK LENGTH SIGN/DISPLAY - SIGNAGE & DISPLAY CASE LCK LCK 23 Z2 Z3 Z2 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 Z3 PANELBOARD: L1 (NEW) FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: FCA +10% MINIMUM, SERIES RATED MAIN SIZE/TYPE: 225A MCB SERVES: THE CONTAINER STORE VOLTS/PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM, ROOM #:112 CKT NO. DESCRIPTION VOLTAMPS/PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS/PHASE DESCRIPTION CKT NO. A B C A B C 1 RCPT -SHOW WINDOW 1 360 / / 1 10 20 1 1 20 12 720 /����/ 7 RCPT -JAN. CLO./VEST (CONN.) 2 3 RCPT -SHOW WINDOW 2 j�/ 12 20 360/j/ 1 10 20 1 1 20 12 /� 500 / RCPT - SOAP DISPENSER 4 5 RCPT -SHOW WINDOW 3 �/ /7/ / 360 10 20 1 1 20 12 %/j/ �/ / j/ 600 RCPT - BREAK RM - FLAT S. TV 6 7 RCPT -SHOW WINDOW 4 720 / ��/�/ 10 20 1 1 20 12 500 360 �f��� DIVCON PANELS (ELEC. RM) 8 9 EWC-1 / 444 // 12 20 1 1 20 12 900 %// RCPT -SALES FLOOR COLUMNS 10 11 RCPT- LOCKERS/SUPPLY/GM OFF / / /7/ / 1,260 12- 20 1 1 20 12 %/j/ // / 500 RCPT - SHREDDER 12 13 RCPT- COMM. RM - CONV.(4) 720 / RCPT- STORE MGR IG - 3 12 20 1 1 20 12 1,260 %/// �� RCPT -SALES FLOOR COLUMNS 14 �/ 15 SPARE 360 %/�/ RCPT- STORE MGR' IG -4 �/ 17 20 1 1 20 12 7 660 CPT- BREAK -SOAP &P. TOWEL DISP.16 17 RCPT POS RM -GEN CONY. �/ j 18 19 12 20 1 1 20 12500 j PWR- ELECTRONIC STRIKES 1819 1.00 RCPT - SHOW WINDOW 5 360/7 j36o RCPT - ELFA IG CPC 4 10 20 1 1 20 12 856 / jj /RCPT- GARBAGE DISPOSAL 20 j/// 21 RCPT - SHOW WINDOW 6 �� / // 360 /j/ 10 20 1 1 20 10 / / / 1,260 RCPT -SALES FLOOR COLUMNS 22 23 AUTO DOOR (2ND FLR ENTRY) 1 // W/f/ 600 10 20 1 1 20 12 %/j// jf//// 500 MOTORIZED DAMPER/ELEC RM 24 25 AUTO DOOR (2ND FLR ENTRY) 1 600 �// 1 10 20 1 1 20 12 1,000 28 / RCPT- BREAK REFRIGERATOR 26 27 SPARE 360 12 20 1 20 20 1 1 20 12 F%W/ 31 0RCPT- BRK RM - M.W. 1 28 29 SPARE20 1 1 20 12 540 1 1 20 121,000 SPARE�j20 RCPT - BREAK RM - VENDING 30 31 SPARE 1 20 20 1 1 20 12 900 %// RCPT- BREAK RM CONV 32 jj/ 33 SPARE � 12 i/// 20 1 1 20 12 �� jf/ 360 RCPT- BREAK ROOM EQUIP 34 35 RCPT-RSTRMS - PAPER T. j///// �j/ 540 12 20 1 1 20 1 7/// �� SPARE 36 SPARE 37 AUTOMATIC DR (FRNT ENTRY) 1 600 / 0 12 20 1 1 20 1 20 W/SPARE38 39 AUTOMATIC DR (FRNT ENTRY) 2 j/ 600 j// 12 20 1 1 20 12�1800 TOTAL PHASE A - VA RECEPT - BREAK RM - COFFEE M. 40 41 SPARE �/ / / LOAD CONN. VA 20 1 1 20 12/j/ / / 500 DOOR CONTACTS 42 SECTION: 2 43 LTG - S.W. PERIMETER(G5) 1,150 �� V�� 1.25 12 20 1 1 20 12 1,800 /����/ LIGHTING LTG - CENTER AISLE SALES (G5) 44 45 LTG - 3.W. PERIMETER(G6) / //� / 1,100 �/ j// 12 20 1 1 20 12 / 1,700 / ����// LTG - CENTER AISLE SALES (G5) 46 47 LTG - 1ST FLOOR ENTRY///� AMPS 41 150 12 20 1 1 20 12 z 1.00 1,300 LTG - CTR BANNERS SALES (G5) 48 49 LTG - N.E. PERIMETER SALES (G6) 1,100 %////// /2 //�/ 12 20 1 1 20 12 1,350 //// f LTG - SOUTH & NORTH VEST. (C5) 50 51 LTG - S.W. SALES (G5) //////,/ 1,250 12 20 1 1 20 12 0� / 500 RECIRC PUMP - WATER HEATER 52 53 LTG - S.E. PERIMATER SALES (G5) 7 1,000 12 20 1 1 20 j/ �� j/ SPARE 54 55 SPARE %/// / // r 20 1 1 20 /77M SPARE 56 57 LTG - N.W. SALES - CASH WRAP (Cr 900 12 20 1 1 20 SPARE 58 59 LTG - N.W. SALES - CASH WRAP ( �/ 1,350 12 20 1 1 20 %/j/ j SPARE 60 61 LTG - EAST SALES 1 (G5) 900 / f / 12 20 1 1 15 12 528 / / EXHAUST FAN #1 (RESTROOMS) 62 63 LTG - EAST SALES 1 (G5) / 1,382 jj 12 20 1 1 20 SPARE 64 65 LTG - SOUTH EAST SALES 1 (G5) j/ 950 12 20 1 1 20 j�/ / j SPARE. 66 67 LTG - SOUTHWEST 1 (G5) 50 0 jj/ 12 20 1 1 20 12 1,080 r�� /� RCPT - ROOF 68 69 LTG - SOUTHWEST 2 (G5) 850/ 12 20 1 1 20 12 850 %//� LTG - SOUTHWEST 2 (G5) 70 71 LTG - CENTER SALES 1 (G5) r/ �� 950 12 20 1 1 20 jj/ / SPARE 72 73 LTG - CENTER SALES 2 (G5) 1,750 /// /77 0 12 20 1 1 20 F / / SPARE 74 75 LTG - CENTER SALES 3 (G5) 1,750 ////// 12 20 1 1 20 12 f/ / 720 RCPT-STOCKRM #101 - 2 76 77 LTG - CENTER SALES 1 (G5) DF %////// / 1,400 12 20 1 1 20 12 j/ ' 180 DF RECEPTACLE 78 79 LTG - CENTER SALES 2 (G5) DF 1,400 �/ / 12 20 1 1 20 12 180 %/j/ / DF RECEPTACLE 80 81 LTG - CENTER SALES 4 (G5) 1,350 jj/ 12 20 1 1 20 12 / j// 180 / DF RECEPTACLE 82 83 LTG - CENTER SALES 5 (G5)j/ /����� 1,550 12 20 1 1 20 12 / �/ 500 LTG - EXT BACK LIT NICHES 84 SUBTOTAL 10,160 10,346 10,470 10,174 11,030 5,580 SUBTOTAL TOTAL PHASE A - VA 20,334 LOAD CONN. VA DF LOAD CONN. VA DF REFRIGERATION 1.00 COOLING 1.00 AMPS 169 SIGN/DISPLAY 1.25 HEATING 0 TOTAL PHASE B - VA 21,376 KITCHEN 6,616 0.65 LIGHTING 30,232 1.25 AMPS 178 EXISTING 1.00 RECEPTACLES 16,524 1.0/.5 TOTAL PHASE C - VA 16,050 LARGE MOTOR 1.25 TOTAL DEMAND MOTORS 2,228 1.00 AMPS 134 SHOW WINDOW 2,160 1.25 60,280 VA SUPP HEAT 1.00 TOTAL PNLBD - VA 57,760 LTG TRACK 1.00 167 A MISC EQUIP 1.00 AMPS 160 PANELBOARD NOTES GF - GFCI TYPE CIRCUIT BREAKER IG - ISOLATED GROUND CIRCUIT FEED THRU CONNECTION: #4/0 Z# - SMART CIRCUIT BREAKER POINT OF CONTACT RTD - REFER TO WIRE DIAGRAM ON SHEET MEP LTG TRACK - TRACK LENGTH LCK-LOCK-OFF DEVICE SIGN/DISPLAY - SIGNAGE & DISPLAY CASE GF GF GF IG IG Z3 Z3 Z5 Z3 Z6 RTD GFI Z4 FA IG IG IG IG IG IG IG,T PANELBOARD: CA (NEW) FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 100A AIC RATING: FCA +10% MINIMUM, SERIES RATED ISOLATED GROUND BUS MAIN SIZE/TYPE: 50A MCB SERVES: THE CONTAINER STORE VOLTS/PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM, ROOM #:112 CKT NO. DESCRIPTION VOLTAMPS/PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS/PHASE DESCRIPTION CKT NO. A B C A B C 1 PWR- DOOR BELL 500 / /12 20 1 1 20 12 180 /'/// / RCPT - ELFA CDC 1 2 3 PWR -FACP ��/ 500 j�/ 12 20 1 1 20 12 20 180 RCPT - ELFA CDC 2 4 5 SPARE //j& / 20 1 1 20 12 j/// W/ 180 RCPT - ELFA CDC 3 6 7 RCPT - CONV POS 5 & 6 360 j/ 7 12 20 1 1 20 12 500 20 RCPT - ELFA CDC EQUIP1 8 9 RCPT - ESM (FLOOR BOX) 360 j�/ 12 20 1 1 20 12 / j///7 500 %/�/ RCPT- STORE MGR IG - 1 10 11 RCPT - QUAD - COMM RM fj Wf 360 12 20 1 1 20 12 11 LTG - SALES EM 2 (NITE LITES) 360 RCPT- STORE MGR IG - 2 12 13 RCPT - CONN. POS 1,2,3 540 % /� 12 20 1 1 20 12 500 ///% RCPT- STORE MGR IG - 3 14 15 RCPT - QUAD 1 - STOCK ROOM IC 540 12 20 1 1 20 12 CONN. VA 360 %/�/ RCPT- STORE MGR' IG -4 16 17 RCPT - QUAD 2 - STOCK ROOM IG7 /� EXHAUST FAN #2(ELEC ROOM) 360 12 20 1 1 20 12 %//// j/ 720 RCPT - GEN MGR (CONN) 18 19 PWR - ELFA CDC - CONV 540 %/// / / 12 20 1 1 20 12 360 1.00 /� / RCPT - GEN MGR (CONV) 20 21 RCPT - ELFA IG CPC 4 180 %/////! 12 20 1 1 20 12 / jj 500 RCPT - POS RM - EQUIP 1 22 23 RCPT - ELFA IG CPC 5 ` �/ 180 12 20 1 1 20 12 1.00 /� 500 RCPT - ADM1 (DIVCON PANEL) 24 25 RCPT - ELFA IG CPC 6 180 %//� 7/� 12 20 1 1 20 12 500 %j/ 7//// RCPT - POS RM - EQUIP 3 26 27 RCPT - POS RM - EQUIP 2 / 180 i'/// 12 20 1 1 20 12 / j// 540 / RCPT -STORE MGR'S-CONV 6 28 29 RCPT- BREAK IG 1 - QUAD ��/ 360 12 20 1 1 20 12 LIGHTING / j//// 360 RCPT- STORE MGR IG - 5 30 31 QUAD - CDC 360 jj/ 12 20 1 1 20 12 540 1.25 77,RCPT - STORE MGR CONY 2 32 33 SPARE�j20 1.00 AMPS 1 1 20 12 �% j/ 180 RCPT- GEN MANAGER IG 34 35 RCPT - L6 -30R f/ / 800 10 30 2 1 20 12 PANELBOARD NOTES PROVIDE EXTERNAL TVSS CONNECT TO PANEL UPS IG - ISOLATED GROUND CIRCUIT T- PROVIDE WITH SPD RECEPTACLE LTG TRACK - TRACK LENGTH SIGN/DISPLAY - SIGNAGE & DISPLAY CASE 500 RCPT- STORE MGR IG - 6 36 1 20 12 180 jj//RCPT- GEN MANAGER IG 38 STOCK RM 800 �j/ % 37 39 RCPT - STOCK ROOM AT CUTTER 300 ��/ 12 20 1 1 20 12 �%/� 360 /�/ RCPT- GEN MANAGER IG 40 41 SPARE j/j /�/�/// 20 1 1 20 12 //� / / 180 RCPT- GEN MANAGER IG 42 SUBTOTAL 3,280 2,060 2,060 2,760 2,620 2,800 SUBTOTAL TOTAL PHASE A - VA 6,040 LOAD CONN. VA DF LOAD CONN. VA DF REFRIGERATION 1.00 COOLING 1.00 AMPS 50 SIGN/DISPLAY 1.25 HEATING 0 TOTAL PHASE B - VA 4,680 KITCHEN 1.00 LIGHTING 1.25 AMPS 39 EXISTING 1.00 RECEPTACLES 15,080 1.0/.5 TOTAL PHASE C - VA 4,860 LARGE MOTOR 1.25 TOTAL DEMAND MOTORS 1.00 AMPS 41 SHOW WINDOW 1.25 13,040 VA SUPP HEAT 1.00 TOTAL PNLBD - VA 15,580 LTG TRACK 1.00 36 A MISC EQUIP 500 1.00 AMPS 43 PANELBOARD NOTES IG - ISOLATED GROUND CIRCUIT T - PROVIDE WITH TVSS RECEPTACALE FA - RED/HANDLE-ON CLAMP LTG TRACK - TRACK LENGTH SIGN/DISPLAY - SIGNAGE & DISPLAY CASE EM,SW EM,SW EM,SW EM,SW EM IG,T IG,T IG,T IG,T IG,T PANELBOARD: INV (NEW) FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 60A AIC RATING: REF 1 REHNEI -LINE MAIN SIZE/TYPE: MLO SERVES: THE CONTAINER STORE VOLTS/PHASE: 480Y/277V, 1PH, 3W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM, ROOM #:112 CKT NO. DESCRIPTION VOLTAMPS/PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS/PHASE DESCRIPTION CKT NO. A B A B 1 LTG - S.W. SALES EM 1 (ELCU-200) 448 / / 12 20 1 1 20 12 1,171 / / LTG - BACK OF HOUSE - EMERG 2 3 LTG - S.W. SALES EM 2 (ELCU-200) //00 320 12 20 1 1 20 4 / // RCPT- POS 3 SPARE 4 5 LTG - N. E. SALES EM 1 (ELCU-200) 192 7///// 12 20 1 1 20 7 RCPT- POS 47�/ /�-/// SPARE 6 7 LTG - N. E. SALES EM 1 (ELCU-200) /'//// 256 12 20 1 1 20 RCPT- POS 5 / / / // SPARE 8 9 SPARE 20 // ' // 20 1 1 20 // f /0 SPARE 10 11 LTG - SALES EM 2 (NITE LITES) ,�///// 1,924 12 20 1 1 20 / //// / / 20 SPARE 12 SUBTOTAL 640 2,500 ADT PANEL 2 1,171 15 SUBTOTAL TOTAL PHASE A - VA 1,811 LOAD CONN. VA DF 1 LOAD . CONN. VA DF EXHAUST FAN #2(ELEC ROOM) REFRIGERATION 17 1.00 COOLING / / 1.00 AMPS 7 DISPLAY CASE 20 1.25 TOTAL PHASE B - VA 2,500 HEATING 19 0 KITCHEN 1.00 AMPS 9 LIGHTING 4,311 1.25 EXISTING FIRE SMOKE DAMPERS 1.00 TOTAL PNLBD - VA 4,311 RECEPTACLES / / 1.0/.5 LARGE MOTOR 2 1.25 TOTAL DEMAND 12 400 AMPS 9 MOTORS 24 1.00 SHOW WINDOW / / 1.25 5,389 VA SUBTOTAL 1,440 SUPP HEAT 1,400 1.00 LTG TRACK _ 1.00 11 A CONN. VA MISC EQUIP SUPP HEAT 1.00 PANELBOARD NOTES EM - EMERGENCYLIGHTING/LOCKABLE TAP SW - EMERGENCY FIXTURE TO BE CONTROLLED BY NORMAL BRANCH CIRCUIT VIA ELCU-200 DEVICE (REFER TO E6.2) LTG TRACK - TRACK LENGTH INVERTER PANEL IS NOT PART OF POWER WALL(IFS), PANEL 'INV' IS LOCATED IN INVERTER SIGN/DISPLAY - SIGNAGE & DISPLAY CASE PANELBOARD: UPS (NEW) FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 100A AIC RATING: FCA +10% MINIMUM, FULLY RATED ISOLATED GROUND BUS MAIN SIZE/TYPE: 60A MCB SERVES: THE CONTAINER STORE VOLTS/PHASE: 208Y/120V, 1PH, 3W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM, ROOM #:112 CKT NO. DESCRIPTION VOLTAMPS/PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS/PHASE DESCRIPTION CKT NO. A B A B 1 RCPT- POS 1 180 / / 12 20 1 1 20 7 / SPARE 2 3 RCPT- POS 2 / 7// 180 12 20 1 1 20 , V�/ 180 SPARE 4 5 RCPT- POS 3 180 // 12 20 1 1 20 4 // SPARE 6 7 RCPT- POS 47�/ 12 180 12 20 1 1 20 12 _7 / 500 RCPT- ELEC RM - FACP1 8 9 RCPT- POS 5 180 / // 12 20 1 1 20 12 500 ' // RCPT- ELEC RM - FACP2 10 11 SPARE // 800 20 1 1 20 12 7/ / 500 ADT PANEL 1 12 13 RCPT - POS (EQUIP.) 500 / //// 12 20 1 1 20 12 500 / / ADT PANEL 2 14 15 SPARE // 540 680 20 1 1 15 12 / / 696 EXHAUST FAN #2(ELEC ROOM) 16 17 SPARE / / CONN. VA 20 1 1 20 1.00 /�i��/ SPARE 18 19 SPARE / / 1.25 20 1 1 20 12 // 500 FIRE SMOKE DAMPERS 20 21 RCPT - L6 -20R - COMM RM (SECURITY CAMERAS) 400 / / 12 20 2 2 20 12 400 /'/// CPT - L6 -20R - COMM RM (SECUIRTY CAMERAS) 22 24 /zi// 400 / / 400 23 SUBTOTAL 1,440 760 1,400 2,596 SUBTOTAL TOTAL PHASE A - VA 2,840 LOAD CONN. VA DF SUPP HEAT LOAD CONN. VA DF LTG TRACK REFRIGERATION 1.00 COOLING 1.00 AMPS 24 DISPLAY CASE 1.25 HEATING 0 TOTAL PHASE B - VA 3,356 KITCHEN 1.00 LIGHTING 1.25 AMPS 28 EXISTING 1.00 RECEPTACLES 5,500 1.0/.5 TOTAL PNLBD - VA 6,196 LARGE MOTOR 1.25 TOTAL DEMAND MOTORS 696 1.00 AMPS 30 SHOW WINDOW 1.25 6,196 VA SUPP HEAT 1.00 LTG TRACK 1.00 30 A MISC EQUIP 1.00 PANELBOARD NOTES PROVIDE EXTERNAL TVSS CONNECT TO PANEL UPS IG - ISOLATED GROUND CIRCUIT T- PROVIDE WITH SPD RECEPTACLE LTG TRACK - TRACK LENGTH SIGN/DISPLAY - SIGNAGE & DISPLAY CASE SMART CIRCUIT BREAKER SCHEDULE ZONE NUMBER _ CIRCUIT NO. NAMEPLATE DESCRIPTION Z1 H1-1,3,5,7 ALARM CONTROLLED SALES FLOOR LIGHTING Z2 L1-45,49 INT. DISPLAY LTG - AISLES (TRUCK LIGHTS) Z3 L1-43,44,46,47,50,51,53,57,59,61,63,65,67,69,70,71,73,75,77,79,81,83; H1-15,17,19,25 SALES OPERATING HOURS Z4 L1-84; H1-9, H1-11 EXTERIOR BUILDING LTG AND SIGNAGE Z5 L1-48, H1-21 BANNER LIGHTS (ON 9:00AM TO 12:00AM) Z6 L1-52 RECIRC PUMP (ON 8:00AM TO 10:00PM) / / //12 Notes: 1.) ALL CONTROL ACCESSORIES ARE FACTORY INSTALLED IN THE POWER WALL. 2.) ALL ZONES SHALL BE LABELED INSIDE THE FRONT COVER INDICATING THE LOADS THAT ARE CONTROLLED AS STATED ABOVE. 3.) REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION ON POW -R -COMMAND. 4.) SHORT CIRCUIT CURRENT RATING SHALL MATCH THE RATING OF THE PANELBOARD FROM WHICH THE LOAD IS SERVED. 5.) SEC - SHUTOFF IS CONTROLLED BY SECURITY SYSTEM. IF SECURITY SYSTEM IS ARMED, LIGHT FIXTURES SHALL BE OFF. LIGHTING IS TURNED ON BY TIME SWITCH LIGHT FIXTURES SHALL NOT TURN ON AT PRESET TIME UNLESS SECURITY SYSTEM IS DISARMED. 6.) SECURITY SYSTEM OVERRIDE SHALL BE PROVIDED WHERE LIGHT FIXTURES DO NOT TURN OFF UPON ARMING OF SECURITY SYSTEM. 7.) BMS - EXTERIOR LIGHT FIXTURES AND SIGNAGE SHALL BE CONTROLLED VIA BUILDING MANAGEMENT SYSTEM WITH ASTRONOMIC. TIME SWITCH CAPABLE OF ADJUSTING FOR DAYLIGHT SAVINGS TIME. 8.) REFER TO BAS DRAWINGS FOR ADDITIONAL CONTROL INTERLOCKING DETAILS. CONFIRM ALL SETTINGS WITH OWNER. 9.) CONTRACTOR SHALL PROVIDE ALL LOAD SIDE WIRING. 10.) PROVIDE MANUAL ON/AUTO SELECTOR SWITCH ON COVER FOR ZONE OVERRIDE FROM BAS SYSTEM FOR EACH ZONE TO BE LOCATED IN GEN. MGR'S OFFICE #106. 11.) NO ZONE SHALL BE GREATER THAN 5,000 SQUARE FEET. IG IG IG IG IG IG IG IG IG IG IG IG IG IG IG IG EM IG,T IG,T IG,T IG,T IG,T IG,T IG,T FUSIBLE PANELBOARD: EP (NEW) FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 60A AIC RATING: FCA +10% MIN. FULLY RATED MAIN SIZE/TYPE: MLO SERVES: FIRST FLOOR VOLTS/PHASE: 208Y/120V, 3PH, 4W MOUNTING: RECESSED SECTION: 1 LOCATION: LANDLORD ELECTRICAL ROOM CKT NO. DESCRIPTION VOLTAMPS/PHASE WIRE NO. FUSE AMP P P FUSE AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT NO. A B I C A B C 1 LTG. ELEVATOR (EXISTING) 600 / / //12 20 1 1 20 12 360 7 / //' / RCPT -ESCALATOR (EXISTING) 2 3 RCPT - ELEVATOR SERVICE (EXIST) // / 180 //// 12 20 1 1 20 �/ SPARE 4 5 RCPT - SUMP PUMP ELEV (EXIST) ,/.� 180 12 20 1 1 20 ////1 // / j//j SPARE 6 7 SMOKE AND HEAT DETECT (EXIST) 200 j/j/ 12 20 1 3 20 12 800 ELEVATOR CONTROLLER CAB LIGHTS AND CONTROL PWR 8 800 jj/ 10 9 RCPT - ELEVATOR (EXISTING) ff��� 360 �j 12 20 1 12 / /��7// 800 11 LTG. ELEVATOR ROOM (EXISTING) %/ / / / 500 12 20 1 SUBTOTAL 800 540 680 1,160 800 800 SUBTOTAL TOTAL PHASE A - VA 1,960 LOAD CONN. VA DF LOAD CONN. VA DF REFRIGERATION 1.00 COOLING 1.00 AMPS 16 SIGN/DISPLAY 1.25 HEATING 0 TOTAL PHASE B - VA 1,340 KITCHEN 1.00 LIGHTING 1,100 1.25 AMPS 11 EXISTING 1.00 RECEPTACLES 1,080 1.0/.5 TOTAL PHASE C - VA 1,480 LARGE MOTOR 1.25 TOTAL DEMAND AMPS 12 MOTORS 2,400 1.00 SHOW WINDOW 1.25 5,055 VA TOTAL PNLBD - VA 4,780 SUPP HEAT 1.00 LTG TRACK 1.00 14 A MISC EQUIP 200 1.00 AMPS 13 PANELBOARD NOTES RELOCATE WIRE AND CONDUIT FROM EXISTING PANEL 'LC' TO NEW PANEL EP EP' PANEL SHALL BE LOCATED IN FIRST FLOOR ELEVATOR ROOM LTG TRACK - TRACK LENGTH SIGN/DISPLAY - SIGNAGE & DISPLAY CASE �L13- 003? BAS 8c ELECTRICAL CONTRACTOR COORDINATION: PROVIDE, INSTALL AND SECURE ALL NECESSARY CONDUIT,PATHWAYS AND PULL -STINGS AS PER BAS DRAWINGS AND SPECIFICATIONS. MOUNT AND JUNCTION ALL BAS CONTROL ENCLOSURES, HVAC ENCLOSURES, LIGHTING CONTROL PANEL AND ACCESS CONTROL PANEL (TOTAL OF 3) WIT5H CONDUITS PATHWAYS. ALL LINE VOLTAGE AND LOW VOLTAGE TERMINATIONS TO THE LIGHTING CONTROLS. ALL LOW VOLTAGE TERMINATIONS TO THE LIGHTING CONTROLS. ROUGH -IN ALL NECESSARY CONDUITS, PATHWAYS AND PULL -STRINGS FOR TEMPERATURE SENSORS TO BAS FLOOR PLAN LOCATIONS. ALL CONTROL CABLING TO BE RUN IN CONDUIT UNLESS IT IS IN CABLE -TRAY OR CONCEALED ABOVE ACCESSIBLE CEILING. SENSOR AND/OR THERMOSTAT DROPS ARE TO BE STUBBED UP IN WALLS IN CONDUIT. USE INSULATOR BUSHING TO PROTECT CABLE EXISTING THE CONDUIT STIB-UP. PROVIDE 120 VOLT POWER CIRCUITS TO CONTROL PANEL (ASM1 AND ADM1): PROVIDE ALL MOUNTING OF ASSOCIATED ACCESS HARDWARE AS SHOWN ON BAS DRAWINGS. ALL CONDUIT PATHWAYS TO ANY CABINETS AND BASEBOARD HEATERS AS SHOWN ON PLANS. CONNECT FIELD -INSTALLED SMOKE DETECTORS WHERE AND IF REQUIRED). FIRE ALARM TERMINATIONS OF UNIT MOUNTED SMOKE DETECTORS AND COORDINATE DURING FIRE MARSHALL TESTING. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL (3) 4 GANG JUNCTION BOX AND LOW VOLTAGE WIRING, CONDUIT AND L.V. OVERRIDE SWITCHES SHALL BE LOCATED IN GENERAL MANAGERS OFFICE #106, REFER TO SHEET E2, KEYED NOTE #19. SWITCHES TO BAS LIGHTING CONTROLLER. (6) OVERRIDE REVIEWED OR wITH- NF'PA 70 - NEC- - - I'JUL 2 2 2013 City of -Tukwila BUILDING DIVISION -- REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE PRIMARY AND SECONDARY SUPPORTS FOR THE UNISTRUT GRID SYSTEM, SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. RECEIVED CITY OF TUKWILA JUN 28 2013 PERMIT CENTER il a)LL �� E U i oo • MM 14 :54 f 1 CJ N 2808 Fairmount Street © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM F LJ LJ 0 o_ z z F- 0 J m J 00 Q 00 < wz U W U D 0 0 2 (n (f) V) co n 0 0 0 0 0 0 n 0 0 0 n 0 0 0 No. Date Item REVISIONS JA Drawn TG Checked TG Approved ELECTRICAL PAN ELBOARD SCHEDULES Project No. 13007.00 Date PERMIT - 06.24.13 Last Revision E-6.1 L_ i LC) LO O U CO Cn M M -60 • cJ N NEUTRAL WHT' BLK NORM. POWER UNSWITCHED HOT. 120V OR 277V AS REQ'D. WATTSTOPPER BZ -50 I POWER T PACK RED RED I o� o LINE VOLTAGE TOGGLE SWITCH LIGHTING LOAD NEUTRAL ii' 1 .I I I, I I, , I, J, L TCS HAD THE MANUFACTURER OF THE MILLWORK CENTER THE BASE OF THE TYPE 'S' LIGHT FIXTURE ON THE SIDE OF THE UPPER CASH WRAP PIECE AND DRILL A HOLE INTO THE MILLWORK TO ALLOW FOR THE THREADED CONNECTOR AND POWER FEED TO PASS THROUGH. THE GC SHOULD ONLY NEED TO FEED THE WIRES AND INSTALL AND WIRE THE LIGHT FIXTURE TO THE TRA.N.SEORMER__A.N_D__SWJIC,H ""J 0 W cc J m J m Dallas, Texas 75201 © Good Fulton & Farrell 2006 1J CONTROL OUTPUT I- • COMMON +24VDC 24VDC CEILING OCC. SENSOR • TO ADDITIONAL CEILING MOUNT 24VDC OCC. SENSORS IF REQ'D. CASH WRAP LIGHTING - PLAN NO SCALE (REFER TO LIGHTING PLAN — SHEET E-2.0 FOR LOCATIONS) CCEILING OCCUPANCY SENSOR WITH SINGLE LEVEL LINE VOLTAGE SWITCHING NO SCALE GC TO MOUNT LIGHT FIXTURE PROVIDED BY TCS TO SIDE OF CASH WRAPS AND CONNECT TO TRANSFORMER AND SWITCH - GC TO CONFIRM MOUNTING HEIGHT AND LOCATION WITH TCS TRANSFORMER FOR LIGHT LIGHT SWITCH HENDERSON ENGINEERSI 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM 'r ACCESS PANEL LIGHTING LOAD CASH WRAP LIGHTING - SECTION NO SCALE (REFER TO LIGHTING PLAN — SHEET E-2.0 FOR LOCATIONS) NEUTRAL WHT NORMAL CIRCUIT 0 J RED HOT B LK GROUND GRN/YELLOW WALL MOUNTED PIR OCCUPANCY SINGLE SWITCH NO SCALE TCS HAD THE MANUFACTURER QF THE MILLWORK CENTER THE BASE OF THE TYPE 'S' LIGHT FIXTURE ON THE SIDE OF THE UPPER CASH WRAP PIECE AND DRILL A HOLE INTO THE MILLWORK TO ALLOW FOR THE THREADED CONNECTOR AND POWER FEED TO PASS THROUGH. THE GC SHOULD ONLY NEED TO FEED THE WIRES AND INSTALL AND WIRE THE LIGHT FIXTURE TO THE TRANSFORMER AND SWITCH MOTOR RATED CSI U m z -_I 00 LJ LLJ Z wz O W CD J Z ZOOF LLJ �(/)C)~ CO NEUTRAL WHT' BLK NORM. POWER UNSWITCHED HOT. 120V OR 277V AS REQ'D. S. WATTSTO PPER BZ -50 1 POWER T PACK RED RED -oma o LINE VOLTAGE TOGGLE SWITCH LIGHTING LOAD (RESTROOM #108) N EUTRAL 0 W cc CONTROL OUTPUT r 1 P POWER FAILURE SENSING CONTROL OF NORMAL AND EMERGENCY FIXTURES NORM. POWER • UNSWITCHED 1 HOT.(DUMMY BREAKER) 277V AS REQ'D. (1) DUMMY BREAKERS CAN SERVE ALL (4) 277 VOLT LIGHTING CIRCUITS V COMMON +24VDC 24VDC CEILING OCC. SENSOR • WT -605 J REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC NORM. POWER SWITCHED HOT(SQAURE D POWER BREAKER) 277V AS REQ'D. H1-1, H1-3 H1-5, H1-7 CASH WRAPLIGHTING - ELEVATION NO SCALE JUL 2 2 2013 (REFER TO LIGHTING PLAN — SHEET E-2.0 FOR LOCATIONS) TO ADDITIONAL CEILING MOUNT 24VDC OCC. SENSORS IF REQ'D. _ City of -Tukwila BUILDING DIVISION NORMAL LIGHTING BALLAST(S) NEUTRA MOTOR RATED NORMAL NEU. SWITCH' NORMAL HOT NORMAL NEU. UNSWITCHED POWER SOURCE FOR EMERGENCY FIXTURES EMER. POWER UNSWITCHED HOT. 120V OR 277V AS REQ'D. WATTSTOPPER ELCU-200EMER. LTG. • CONTROL UNIT (TO BE LOCATED IN JUNCTION BOX, CLOSE TO THE INVERTER IN THE ELECTRICAL ROOM) EMER. LIGHTING BALLAST NEUTRAL NEUTRAL WHT BLK INV -1, INV -3 INV -5, INV -7 EMER. NEU. TYPE Al FIXTURE (2) A3 & (1-) A4 TYPE FIXTURES NORM. POWER UNSWITCHED _ HOT. 120V OR 277V AS REQ'D. WATTSTOPPER BZ -50 1 POWER T PACK RED RED O� O LINE VOLTAGE TOGGLE SWITCH LIGHTING LOAD (RESTROOM #109) NEUTRAL 0 w cc D J CO 277V/120V CONTROL RELAY 120 VOLT EXHAUST FAN MOTOR RATED DISC. SWITCH No. Date Item L_ J INVERTER L_ J SQUARED MOTORIZED BREAKER PANEL CONTROL OUTPUT r • A4 A3 1.1111111 A3,. Al COMMON +24VDC • 24VDC CEILING OCC. SENSOR WT -605 1 REVISIONS 120V, 10 JA H ROOF LEVEL RECEIVED CITY OF TUKWILA Drawn JUN 28 2013 TG Checked Al A3 A3 A4 TYPE 'Al' EMERGENCY FIXTURE SHALL BE CONTROLLED WITH (2) 'A3' AND (1) 'A4' TYPE FIXTURE ON CIRCUIT HA -5. THE TYPE 'Al' SHALL BE SERVED(POWERED) BY THE INVERTER CIRCUIT INV -9. 1 I HSALES LIGHTING NORMAL/EMERGENCY (TYPE A FIXTURES) LIGHTING CONTROL WIRE DIAGRAM NO SCALE 4 TO ADDITIONAL CEILING MOUNT 24VDC OCC. SENSORS IF REQ'D. PERMIT CENTER TG Approved CEILING MOUNTED OCCUPANCY SENSOR WITH SINGLE LEVEL LINE VOLTAGE SWITCHING AND RELAY TO TURN EXHUAST FAN ON WITH RESTROOM LIGHTS NO SCALE ELr&O&39 LIGHTING DETAILS Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E-6.2 SUPPORT GFRG COVES WITH HANGER WIRES TO ROOF STRUCTURE - TYP. J -BOX FOR LIGHT FIXTURE POWER - REF: MEP MONO -POINT LIGHT FIXTURES MOUNTED TO GFRG COVE - REF: RCP & MEP GFRG LIGHT COVE - PAINT P-1- FLAT TYP. 4" M AL STUD BRACE © 32" C. A —.mum � i / SLEEVE THREADED RODS THROUGH GWB - SEAL GWB TIGHT AROUND THREADED RODS - TYPICAL ALL LOCATIONS B.O. GWB CEILING 15'-0" & 17'-0" A. SUSPENDED GWB CEILING SYSTEM - PAINT P-1 FLAT A UNISTRUT #P1 " 5 90° ANGLE WITH NUTS AND BOLTS - FASTEN INTO METAL STRAPPING CONCEALED WITHIN WALL ONE LAYER 5/8" GWB OVER 4" STUDS © 16" O.C. - EXTEND GWB TO 6" ABOVE CEILING - EXTEND STUDS TO DECK - TYP. 18 GAUGE x 8" CONTINUOUS METAL STRAP BEHIND GWB OVER STUDS, TYP. - FOR ATTACHMENT OF UNISTRUT GRID TO FASCIA - HOLD STRAPPING BELOW J -BOXES TYP. UNISTRUT GRID SYSTEM - REF: A4.10 B.O. LIGHT FIXT 10-8" A.F.F. MONO -POINT LIGHT FIXTURES NOT TO SCALE EXTEND GWB HANGERS TO ROOF DECK - TYP. SECONDARY SUPPORT STRUCTURE SECURED TO ROOF FRAMING FOR UNISTRUT GRID HANGERS - HANGERS MUST BE LOCATED AT GRID INTERSECTIONS ONLY B.O. GWB CEILING _.._..-.._.. 12'-0" A.F.F. MOUNTING AND CIRCUITING DETAIL SECONDARY SUPPORT STRUCTURE SECURED TO ROOF FRAMING FOR UNISTRUT GRID HANGERS - HANGERS MUST BE LOCATED AT GRID INTERSECTIONS ONLY EXTEND GWB HANGERS TO ROOF DECK - TYP. TAP HOLES THROUGH UNISTRUT AT LOCATION OF KNOCK -OUTS IN J -BOX - TYP. 90° CONNECTOR - UNINSULATED - GRAINGER 3LL22 OR EQUAL - TYP. OF (2) PER J -BOX MC -CABLE INSIDE UNISTRUT - PAINT P-1 WHERE EXPOSED TO VIEW EXTEND GWB HANGERS TO ROOF DECK - TYP. SECONDARY SUPPORT STRUCTURE SECURED TO ROOF FRAMING FOR UNISTRUT GRID HANGERS - HANGERS MUST BE LOCATED AT GRID INTERSECTIONS ONLY SUSPENDED GWB CEILING SYSTEM REF: A4.11 & A4.12 FOR DETAILS (BY OTHERS) SLEEVE THREADED RODS THROUGH GWB - SEAL GWB TIGHT AROUND THREADED RODS - TYPICAL ALL LOCATIONS PLATE AS REQUIRED FOR CONDITION- SEE 06/A4.10 MC CABLE IN STRUT DRILL HOLE IN BOTTOM OF STRUT FOR MC i CABLE TO EXTEND INTO J -BOX - NO EXPOSED matimir CABLE PERMITTED BOTTOM OF UNISTRUT E1= RCP - 4 -0 J -BOX FOR MONO POINT LIGHT FIXTURE - PAINT P-1 (TYP.) MONO -POINT TRACK HEAD REF: MEP ALL MONO -POINT FIXTURES MOUNTED TO UNISTRUT ARE TO BE FED WITH MC -CABLE PAINTED P-1 - NO EXCEPTIONS LIGHTING INSTALLATION DETAIL FEEDS - TYPE 'G5' AND G6 FIXTURES NOT TO SCALE SLEEVE THREADED RODS THROUGH GWB - SEAL GWB TIGHT AROUND THREADED RODS - TYPICAL ALL LOCATIONS SUSPENDED GWB CEILING SYSTEM - REF: A4.11 & A4.12(BY OTHERS) 3/8" DIA. THREADED ROD - PAINT P-1 11 111111111111 J -BOX CONCEALED ABOVE CEILING WITH CANOPY PLATE AND S/O CORD FROM LIGHT FIXTURE - REF: MEP - PLATE AND S/0 CORD PROVIDED BY TENANT FE R GC INSTALL AIM IINErdi PROVIDE AND INSTALL P-1280 END CAPS AT ALL OPEN ENDS OF UNISTRUT - PAINT P-1 - TYP. THROUGHOUT FLUORESCENT LIGHT FIXTURE AS SCHEDULED - SUSPEND FROM BOTTOM OF UNISTRUT WITH MFR. STANDARD SUSPENSION KIT ROUND COVER PLATE PROVIDED BY TENANT FOR GC INSTALL CENTER ON FIXTURE RUN - TYPICAL PLATE AS REQUIRED FOR CONDITION- REF: 06/A4.10 SLEEVE THREADED RODS THROUGH GWB - SEAL GWB TIGHT AROUND THREADED RODS - TYPICAL ALL LOCATIONS P1012 CHANNEL NUT P1000 UNISTRUT - POWDER COAT WHITE 3/8" 0 X 1" STAINLESS STEEL HEX -HEAD BOLT - COORDINATE THREAD TYPE WITH LIGHT MFR. SUSPENDED GWB CEILING SYSTEM - REF: A4.11 & A4.12 POWER CORD WHIP FROM FIXTURE REF: A2.01 AND MEP REFER TO A4.10 & A4.11 FOR TYPICAL NOTES AND DIMENSIONS. 3/8" DIA. THREADED ROD - PAINT P-1 SATE AS REQUIRED FOR CONDITION- SEE 06/A4.1 0 POWER CORD WHIP FROM FIXTURE REF: MEP - CEILING MOUNTED FEEDS FOR REGULAR AND EMERGENCY POWER COME FROM CEILING AT 4'-0" IN FROM END OF RUN REFER TO A4.10 & A4.11 FOR TYPICAL NOTES AND DIMENSIONS. B.O. UNISTRUT 1 1" A.F.F. 1 /2" 0 X 1" STAINLESS STEEL FEMALE CONNECTOR - PART OF HANGING KIT FROM MFR. STAINLESS STEEL CABLE - PART OF HANGING KIT POWER CORD WHIP FROM FIXTURE REF: MEP THIS DETAIL ADDRESSES THE CONDITION WHERE THE EMERGENCY AND. REGULAR POWER FEEDS COME FROM THE CEILING ABOVE - REFER TO 01 /A4.10 FOR DETAIL WHERE THE EMERGENCY AND REGULAR POWER FEEDS COME FROM THE BULKHEAD 000 000 000 000 000 000 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00 00 00 CO 00 00 00 oaoo 0000 0000 0000 0000 0000 0000 00' O."^ 000 000> 00> 000, 00. 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00 00 'o0 >00 00 00 00 >00 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 oaoo 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 oaoo 0000 0000 0000 0000 0000 0000 00' O."^ 000 000> 00> 000, 00. 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00 00 000 000 0000 0000 0000 0000 E I _ 1 L�iifi'1 FLUORESCENT LIGHT FIXTURE AS SCHEDULED - SUSPEND FROM BOTTOM OF UNISTRUT WITH MFR. STANDARD SUSPENSION KIT PLATE AS REQUIRED FOR CONDITION- SEE 06/A4.10 THIS DETAIL ADDRESSES THE CONDITION WHERE THE EMERGENCY AND REGULAR POWER FEEDS COME FROM THE BULKHEAD - REFER TO 06/A4.10 FOR DETAIL WHERE THE EMERGENCY AND REGULAR POWER FEEDS COME FROM THE CEILING ABOVE .0. FIXTURE0 10'-8" A.F.F. LIGHTING POWER FEEDS - TYPE 'A' FIXTURES NOT TO SCALE 000 0000 0000 0000 0000 0000 0000 00 000 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00 00 000 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00 00 000 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00 00 ^00 >00 00 00 0>0 0 N SLEEVE THREADED RODS THROUGH GWB - SEAL GWB TIGHT AROUND THREADED RODS - TYPICAL ALL LOCATIONS (BY OTHERS) WHITE CAT 6 PATCH CORD WITH LABEL AT END BY DATA SUB FROM DATA PORT IN FASCIA SYSTIMAX PART # 107984015 BY DATA SUB - MOUNT TO TOP OF UNISTRUT RECESSED JUNCTION BOX WITH DATA FACEPLATE AND SINGLE DATA TERMINATION AND LABEL PER DIVISION 26000 - WITH CAT6 DATA LINE (PLENUM RATED) BACK TO ERVER IN COMMUNICATIONS ROOM BY DATA SUB WIRELESS ANTENNA INSTALLED BY TCS UNISTRUT GRID WIRELESS ANTENNA DETAIL NOT TO SCALE CAT6 DATA LINE (PLENUM RATED) BACK TO SERVER IN COMMUNICATIONS ROOM BY DATA SUB GC TO CONFIRM ALL ROUGH -IN REQUIREMENTS AND DIMENSIONS WITH TCS P.M. PRIOR TO BEGINNING WORK REF: CAM -1.10 FOR LOCATION SUSPENDED GWB CEILING SYSTEM & GWB FASCIA (BY OTHERS) SYSTIMAX PART # 107984015 BY DATA SUB 3/4"0 GROMMETED H JLE IN GWB BY GC 6'-0" LONG WHITE Cf WITH LABEL AT END CONNECTION TO CA CAMERA VENDOR T 6 PATCH CORD BY DATA SUB - MERA BY SUSPENDED GWB CEILING SYSTEM CAMERA & PLATE INSTALLED BY CCTV VENDOR ®CAMERA DETAIL NOT TO SCALE SECURE SUSPENDED CEILING HANGERS TO DECK OR STRUCTURE (TYP). (BY OTHERS) SPENDED GWB CEILING SY TEM - PAINT P-1 (BY OTHERS) I 1 U 2 3/4 ff LIGHT FIXTURES MOUNTED TO UNISTRUT GRID - REF: RCP & MEP B.O. LIGHT FIXT 10'-8" A.F.F. PAINTED GWB FASCIA P-1 SEAL PERIMETER OF DIFFUSER W/NEOPRENE GASKET - TYP. (BY OTHERS) THREADED ROD HANGERS FOR SUPPORT OF UNISTRUT - PAINT P-1 - REF: A4.10 FOR DETAILS J -BOX CONCEALED WITHIN WALL WITH CANOPY PLATE AND S/O CORD FROM LIGHT FIXTURE - REF: MEP - PLATE AND S/O CORD PROVIDED BY TENANT FOR GC_ INSTALL UNISTRUT #P1325 90° ANGLE WITH NUTS AND BOLTS - FASTEN INTO METAL STRAPPING CONCEALED WITHIN WALL DASHED LINE INDICATES EXTENT OF 18" GAUGE X 8" CONTINUOUS METAL STRAP BEHIND GWB UNISTRUT GRID SYSTEM - REF: A4.10 BOTTOM OF GWB SOFFIT BEYOND B.O. GWB CEILING0 15'-0" A.F.F. ELVOb37 LIGHT FIXTURE SERIES 'A' AND 'G' NOT TO SCALE POWER FEED DETAIL REVIEWED FOR wvAPLIANCE WITH NFPA 70 NEC JUL 2 2 2013 ILPING J -BOX CONCEALED WITHIN WALL WITH CANOPY PLATE AND MC CABLE RUN INSIDE STRUT TO FEED MONO -POINT HEADS - REF: MEP - PAINT MC CABLE P-1 TYPICAL 1/2" B.O. GWB CEILING 12'-0" A.F.F. J -BOX FOR LIGHT FIXTURE MOUNTED TO UNISTRUT - PAINT P-1 MONO -POINT LIGHT FIXTURES MOUNTED TO UNISTRUT - REF: RCP & MEP & 02/A4.10 RECEIVED CITY OF TUKWILA JUN 2 8 2013 PERMIT CENTER i 0 L O I- ---I .--1 O U M M • '4 '4: } N 2808 Fairmount Street © Good Fulton & Farrel HENDERSON ENG1NEERSK 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 Fax 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM n 0 0 0 0 n 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS TG Drawn TG Checked TG Approved LIGHTI NG DETAILS Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E-6.3 O O SM LACAR SLIVER MESH BASKET LADDER L_ C \\ STORE \\\\ MANAGER'S `\ OFFICE \ / / / / / / / / / / / / DIRTY POWER TO LOCKERS RECESSED CORNER GUARDS COMMUNICATION AREA 86" „ 11 u u WALL —0 1/4" / / HISTORY POSTER ( o"w x 34"h x 21 d) \ RECESSED CORNER 7 II # II 1 71 1 1 ii GUARDS NEW PRODUCTS DISPLAY DIRTY POWER 1! BULLETIN 1 1' I BULLETIN i ! II ' BOARD 1 .1 : • _: i ; t- LF!- -it- 1 TV' CART i i -111 „ I CLEAN POWER! 1 I j I ! ! 1 1. 1.�' � 1 \ \ N !' OPEN TO SUPPLY & JANITOR'S CLOSET ' I II I ' tt a 1 I ; POWER I HREDDR 1 I \\TO SALES `FLOOR \\ ` ' \ PHONE,DATA 11 DIRTY POWER „ 12 !©© X 6 \\ 1'-9„ \ 2'-7" I� • ! € I OVER/ [SHORT it OCC. \` CLEAN RECESSED CORNER !II ! ; GFCI DUPLEX DIRTY 'OWER SWITCH 6�°' \ t.... GUARDS 0 \ H—u ° r--- i HUDDLIE 1 1 , '_9„ 1 ! 11 \ \\ / I hn. r�r;,. ---F1-11,' 1 i ELFA UNIT FOR ;—E3 = 16 " I I ! L--- J i I / C / 4r n 1DIRTY POWER 1=1,1_4111_____.„..i 1 ! II !1 I 11 i r./ O ' I I 1 i I 1 /' / / // /71- ' /' /' / / 2 FIL: CABIN -o u T i- \ I 1 f S RH-A � Roo„ REFER TO DIVISION 25000 I\ SPECIFICATIONS FO ADDITIO\AL SCOPE OF WOK. SEE ALSO ADT -1.10, ADT -1.20, CAM 1.10, A\D S-1.0 FO ADDITIONAL SCOPE EC \OTE LOCATIO\S OF SPD OUTLETS ON THIS SHEET A\D 0\ E-8 NOTE #1 GC TO PROVIDE AND INSTALL THE FOLLOWING AT THIS LOCATION: (1) EXTRON ELECTRONICS - AAP -102 - WHITE #60-300-3 TWO GANG MP MOUNTING FRAME (1) EXTRON ELECTRONICS - WHITE W/SILKSCREEN - #70-101-83 15 -PIN FEMALE TO FEMALE GENDER CHANGER, ONE 3.5MM STERO MINI JACK TO SOLDER TABS (1) EXTRON ELECTRONICS DOUBLE BLANK PLATE - WHITE # 70-090-22 (1) EXTRON ELECTRONICS HDMI M -M SERIES HIGH PERFORMANCE HDMI MALE TO MALE CABLE - HDMI M -M/12 #26-613-03 - PLENUM RATED - RUN FROM TV TO POS OFFICE (1)EXTRON ELECTRONICS VGA M -M MD SERIES MALE TO MALE VGA MOLDED CONNECTOR CABLE - VGA M - M MD -15 #26-238-02 - PLENUM RATED - RUN FROM TV TO POS (1) EXTRON ELECTRONICS STP22 CABLE - SERIAL CONTROL/AUDIO CABLE - STP22P/1000 #22-158-03 -PLENUM RATED - RUN FROM TV TO POS OFFICE - INSTALL (1) HDMI FEMALE TO FEMALE BARREL JACK AT EACH END OF THIS CABLE - COLOR: WHITE #70-616-03 NOTE #2 GC TO PROVIDE AND INSTALL THE FOLLOWING AT THIS LOCATION: (1) EXTRON ELECTRONICS - AAP -102 - _WHITE #60-300-3 TWO GANG MP MOUNTING FRAME (1) EXTRON ELECTRONICS - WHITE W/SILKSCREEN - #70-101-83 15 -PIN FEMALE TO FEMALE GENDER CHANGER, ONE 3.5MM STERO MINI JACK TO SOLDER TABS (1) EXTRON ELECTRONICS DOUBLE BLANK PLATE - WHITE # 70-090-22 CONNECT ALL CABLES COMING FROM THE TV IN THE BREAK ROOM TO THESE CONNECTORS REFER TO NOTE 1 THIS SHEET O O 0 WALL 'A' 1 02) FLF`JATIO\S O O r 2'-0" r STORE EVENT CALENDAR L DIRTY QUAD POWER CLEAN QUAD POWER PHONE/DATA DATA WITH (1) PORT - RUN (1) DATA LINE IN CONDUIT TO SERVER IN COMM ROOM 107 PLASMA TV BY TCS (NIC) T -STAT - REF: BAS \ \ POS`, CARD READER TRASH BY TO GFINIC) TYPICA O C O / / / / / / / / / / REFER TO NOTE #1 THIS SHEET CLEAN POWER FOR TV W/ SPD • 3' '2" I L f 7 IT -1 r ! I! 11 II II OMMUNICATIC1 ! pbARDS BY TS -IC -1'4- ----- J O cc 1 J L JL JL J DIRTY POWER r. O C / / / / \ N GENERA MANAGER \\ \ 2'-0" I -n 1 # 1 1 I 1 1 I - 1 LAPTOP STATIONS r! ! I 1 I I! 7 II # II 1 71 1 1 ii FREFRIGER �Y TCS ( TY 1 PICAL,/,,72" 1_EFT HAN 1 " X 30 DIRTY POWER 1! BULLETIN 1 1' I BULLETIN i ! II ' BOARD 1 .1 : • _: i j 11 i BULLETIN ! !1 ! I1 : a A RD ! 1 TV' CART i i -111 „ I CLEAN POWER! 1 I j I ! ! i! � !' HONE/DATA ' I II I ' tt i ; POWER I HREDDR 1 I _ pLEAN PHONE,DATA 11 DIRTY POWER !©© X I I I 1'-9„ 2'-7" I� • WALL ' D' it CLEAN 1POWER !II ! 200 GFCI DUPLEX DIRTY 'OWER 6�°' \ t.... _ 0 \ H—u '_9„ 1 ! 11 `',0 I hn. r�r;,. ---F1-11,' 1 i ELFA UNIT FOR ;—E3 u7 DIRTY POWER oI 4r n 11 RECRUITING FILES i 1 I ri� - 2 FIL: CABIN © T 2 co \ I 1 f CO I IW/ I Co I WALL 'D 2'-4" 2'-4" 2'-9" I i DOOR SWING AGAINST WALL r I ; PHOTO POSTER ; VENDING MACHINE BY Tt (NIC) TYPICAL 30" X 34" X S FREFRIGER �Y TCS ( TY 1 PICAL,/,,72" 1_EFT HAN 1 " X 30 ( ,- k / i/ I /" I �, I H N I I \\ 1 I N. I CABINET N. 1 ��, OR,/ 7 ! V UPPER (48"w x t1 �� 9' i !; Al'4"h x 14"d) , " --- - ! - ---,-- ��-- � ! I 11i V� . , n2 u II II II___ �1 POWER DIRTY DIRTY POWER � \;L---, 1 I I. POWER I HREDDR 1 I _ pLEAN 11 DIRTY POWER 1-8„ _8„ 1'-0' X I I I 1'-9„ 2'-7" • WALL ' D' 11 1 1 1 1 H GFCI DUPLEX DIRTY 'OWER 6�°' \ t.... H—u '_9„ 2'-8" `',0 hn. r�r;,. ---F1-11,' / r CO I I Co I .'' N ♦ it ♦ ♦ 1 j,WALL 'cWsLL MAGNETIC DRY ERASE WALL WALL 9 2'-5" 7' 1 „ —7" PROVIDE & INSTALL GFCI POWER UNDER COUNTER FOR INSTA-HOT,, SOAP DISPENS AND GARBAGE DISPOSAL BRA oov / / / / / ocC. //SENSOR/ // SWITCH • /===0 / O \ SINGLE WORK STATION -FP L O DATA CLEAN POWER DIRTY POWER PHONE/DATA CLEAN POWER 5,-9„ RV ELEC- AUTO DISPE SWIT' DISP GFC I LSV ELFA UNIT WITH B/W PRINTER DIRTY POWER CI \t C 1 !; • I D001 SWING AGAINS1 WAL WALL 'B', STORE_VA\ACPR(RV ' -L1 '��WALL 1 0/; ELI -V . CR: WORK STATION SERVICE '3y 1! * r DESK/AT HOME r`r I I II 11 II *1 I I 1 ; 1 R I I _ DOOR SWING AGAINST WALL I TVSS 7 ! II ! II'II ( IIIII I I ! 'HONE/DATA Lf� I u II II II___ �1 POWER DIRTY DIRTY POWER � \;L---, 1 I I. POWER I HREDDR 1 I _ pLEAN 11 DIRTY POWER I I I I I 1'-9„ 2'-7" • WALL ' D' 11 1 1 1 1 H 2 0 1 N H—u '_9„ 2'-8" WALL / O 0 J . WORK STATIONEp PP� DATA r CLEAN POWER N(/ TVSS 7 (::: 011 - DIRTY POWER DOOR SWING AGAINST WALL u O I } Lf� I u I DIRTY DIRTY POWER � \;L---, 1 I I. POWER I HREDDR 1 I I I I I I 1'-9„ 2'-7" • WALL ' D' / / SIDE OF SAFE DIRTY POWER Co WALL 'C' , 4'-6" DIRTY POWER 4'-6" xref .\SECOND FLOOR.DWG MONEY COUNTING COUNTER 11 II II I 11 1= U__ 4 DATA/PHONE CLEAN POWER DIRTY POWER i REFER TO NOTE #2 THIS aSt-i= N 00 ' I \ RIGHT 77 I 1 I1r\L= 1 I LJ SAFE: HAND\OPEI / U 2'-4" / / / / / OCC. /' SENSOR/ SWITCH C „ WALL 'B' WALL 'A' PT - GM SHELVING IT L O U H U DATA CLEAN P,QWER DIRTY POWER u WALL 'C' WALL 'B' C \ERAL 4'-0" V A\ACR DIRTY POWER Co r L 3'-0" VOLUME CONTROLS - REF: S-1.0 - GC CONFIRM EXACT LOCATION AND CONFIGURATION OF VOLUME CONTROLS WITH TENANT'S SOUND SYSTEM VENDOR AND PROJECT MANAGER PRIOR TO ROUGH -IN - INCORPORATE ALL INTO A SINGLE 5 -GANG BOX AND FACE PLATE -SECURITY WHITE CAMERA EQ. N OCC. / SENSOR/ SWITCH DATA CLEAN POWER DATA CLEA N POWER MANUAL OVERRIDE SWITCHES FOR SALES FLOOR LIGHTS - INCORPORATE ALL INTO A SINGLE 5 -GANG BOX AND FAC PLATE - WHITE RV 1 06; ALL LEVAT 0\S 1 WOIMI I 0 B 11 REFER TO SHEET E-8.0 ID AB� _O C'< IRS REFER TO SHEET E-8.0 'D A + C STOP VCR, 14- II II 'D B REFER TO SHEET E-8.0 103 S„PPL Y BR A 4D B C ROOV A D B 06 G VA\ PAL AG 105 SOS A D B c G BACK OF HOUSE KEY PLAN 1/4"=1'-0" LVOb3 q REVIEWED FOR COMPLIANCE WITH__ NFPA70=NEC_ _ __ JUL 2 2 2013 City of TukWlla BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 28 2013 PERMIT CENTER N ig .c: H (N .Lr) -'r-- 0 M M • N N . CD Cn © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 Fax 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM 0 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS JNA Drawn Checked Approved BACK OF HOUSE ELECTRICAL ELEVATIONS Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E-7,0 OPEN TO JANITOR'S CLOSET RECESSED CORNER GUARDS S,J REFER TO DIVISION 25000 IN SPECIFICATIO\S FOR ADDITIONAL SCOPE OF WORK. SEE ALSO ADT -1 .10, ADT -1.20, CAVI 1.10, A\ D S-1.0 FO ADDITIONAL SCOPE EC NOTE LOCATIO\S OF TVSS OUTLETS 0\ THIS SHEET AND ON E-7 (2) 1"0 CONDUITS FCR (8) CAT -6 LINES TO COMMUNICATIONS ROOM — (SER -1 THROUGH SE —8) REFER TO E-3 FOR ROUTING (2) 1 "0 CONDUITS FOR (8) CAT -6 LINES FROM BUILDING DEMARK LOCATION — (EXT -1 THROUGH EXT -8) GC TO COORDINATE ROUTING WITHIN BUILDING - INTEGRATED POWER SYSTEM (POWER—WALL) FURNISHED BY TENANT INSTALLED BY GC WALL DIRTY POWER PHONE/DATA ELFA UNIT 2 r OPEN TO BREAK ROOM OCC. SENSO SWITCH / WALL 'D' DDLY ROOV 3'-3" RV FIRE ANTENNA & DIALER PROVIDE CONCEALED CONNECTION TO PHONE UTILITY (2) 20 AMP ISOLATED GROUND DUPLEX OUTLETS WITH TVSS ON UPS ROUND BAR WALL 'C 1 03) HLFVATO\S ELFA CART LIITERATU RAC K RE HOOK FOR EASEL DjIRTY POWER I CD ELFA UNIT °" WALL B' OFFICE SUPPLIES H 7 F u 7 7 SIGN STATION 4R 7 7 J ELFA CART U SJDDLY ROOV RV WALL 'A' 1 03) PLLVATO\S F CABLE TRAY PROVIDED AND INSTALLED BY DATA 1 '-0" 3f_9ff CABLING SUBCONTRACTOR TRAY PROVIDED INSTALLED BY DAT SUBCONTRACT 1 L (2) 20 AMP ISOLATED GROUND DUPLEX RECEPTACLES W/TVSS FOR SERVER CABINET ON UPS — MOUNT ON SIDE OF LADDER uni iiiiiiiiiiiiiiiiiiiii RACK — COORDINATE INSTALLATION AND ALL OTHER REQUIREMENTS WITH TCS FURRED OUT 1'-2" PROJECT MANAGER PRIOR TO COLUMN N ROUGH IN— (N \ N OOR STANDING 2 POST RELAY 1 0 0 0 _\____IDIRTY RACK — CHATSWORTH PART ^ O I POWER '_\ #46353-708 ALTERNATING WIRE MANAGERS PER DIVISION 26 . ,. SERVER CABINET ON CASTERS CAN BE MOVED OUT FOR MAINTENANCE DIRTY POWEI4 (ON WALL BEHIND EQ. CO L_1 J k 4'-6" WALL 'D CAT6 DROPS VERTICAL WIRE MANAGER — CHATSWORTH PART #30095-708 FURRED—OUT COLUMN OVERHEAD PAGING 16 U RESERVED FOR MOOD MEDIA CABLE TRAY PROVIDED AND INSTALLED BY DATA CABLING SUBCONTRACTOR (2) 20 AMP ISOLATED GROUND DUPLEX RECEPTACLES W/TVSS FOR SERVER CABINET ON UPS — MOUNT ON SIDE OF OF LADDER RACK — COORDINATE INSTALLATION AND ALL OTHER REQUIREMENTS WITH TCS PROJECT MANAGER PRIOR TO ROUGH IN OCC. SENSOR/ SWITCH C ff O * 3'-2" CENTER OF TR Y T—STAT — �REF: BAS 111 DATA W/2 DROPS FOR 6.2 PHONE SINGLE 20 AM I.G. CIRCUIT WI H SPD (SPARE) WALL 1" 71 - \iii DATA W/2 DROPS 2 0 DIRTY POWER r. DOOR SWING AGAINST WALL 4'-1" COV / VJ\ (2) 20 AMP ISOLATED GROUND PASS & SEYMOUR 208V NEMA L6 -20R OUTLETS TO UPS 20 AMP ISOLATED GROUND CIRCUIT WITH SPD TO UPS FOR SOUND SYSTEM GROUND BAR W/#6 THHN WIRE BACK TO SERVER CABINET WALL 'B' ICAT 0\S R00 V R 5, k 1 07\ R WALL 'A' HLIVAT ONS (1) 2"0 CONDUIT FOR 25 PAIR PHONE CABLE FROM BUILDING DEMARK — GC COORDINATE ROUTING INSIDE BUILDING PHONE UTILITY AND 110 BLOCK (1) 1/2"0 CONDUIT FOR PHONE CABLES FROM PHONE UTILITY TO SECURITY SYSTEM — GC TO CONFIRM REQUIREMENTS WITH TENANT'S 4ECURITY VENDOR 91 FACT: 11 FAC 1' ADT SECURITY ANTENNA & DIALER PROVIDE CONCEALED ADT , SECURITY ADT ECU.RI1Y CONNECTION TO PHONE UTILITY (2) 20 AMP ISOLATED GROUND DUPLEX OUTLETS WITH TVSS ON UPS GROUND BAR EMERGENCY LIGHTING CONTROL UNITS INSTALLED WITHIN RECESSED JUNCTION BOXES AS SHOWN — WATTSTOPPER ELCU 2000 — PROVIDE BLANK COVER PLATES LABELED 'ELCU' REMOTE TEST STATIONS FOR RTU — TEMP SENSOR OCC. SENSOR/ SWITCH BRACKET MOUNTED FIRE EXTINGUISHER 6 PROVIDE CONCEALED SPACING PLATE c UPS — SUPPLIED BY TENANT AND INSTALLED BY GC WITHIN WALL FRAMING WATER HEATER MTD. ON HOUSEKEEPING PAD FRP PAN ELS WALL SWITCH FOR RECIRCULATING PUMP AND AQUASTAT DISCONNECT SWITCH FOR WATER HEATER CLEANING SUPPLIES r1 II II ! JL I�T11— T-1—r-T�I ILLJ 11 L 1 a- r-1-1-_77-rT1 L1 J—LI—I—L1 14- I 3i A WATER HEATER MTD. ON HOUSEKEEPING PAD WALL 'C WALL 'C' HOOK FOR WIDE STEPSTOOL GFI OPEN TO JANITOR'S CLOSET f WALL 'B 9 SPD DATA WITH (3) DROPS MOUNTED INSIDE POWER WALL —COORDINATE EXACT LOCATION WITH BAS VENDOR PRIOR TO INSTALLATION INTEGRATED POWER SYSTEM (POWER—WALL) FURNISHED BY TENANT INSTALLED BY GC EMERGENCY LIGHTING INVERTER AND BATTERY CABINET — SUPPLIED BY TENANT AND INSTALLED BY GC 2'-7" N ▪ A= 0=7=S an CA 0 t GC C = UPS — SUPPLIED BY TENANT AND INSTALLED BY GC DATA WITH (1) DROP AT WALL FOR UPS UNIT — COORDINATE EXACT LOCATION WITH BAS VENDOR PRIOR TO INSTALLATION IIIIIIIIIIN111111IIUIIIIIIIIIIII 111 lull 1Effilliii 2'-7" Ill!lllllllllllllgllllllllllllIIIII Illuulull IIIIIIgUII IIIIII11uli Illlpulllpum» U1 Illlllllll UIIIIIIIllIiIIIIIIIUllll1111fE 0' HOOKS 7,7 FRP PANEL GFI WALL 'B' WALL 'A' JA\TOH (RV 1 1 1; FL IVATO\S ELFA HANGING/STORAGE AREA T_ SHELVES I ji iI SHORT HANG DIRTY POWER jj Il LONG HANG I I I (i IJ WALL � 9 13'-7 1/2" LOCKERS i rt WALL IRTY 140WER ;' I CD I OPEN TO BREAK ROOM LOC DIRTY POWER 4, � I WALL '8' R Rcov LOCKERS LECT rairrnfretarrn C R00`,/ B i I I •I WALL 'A' 1 1 2) F LHVATO\S ■111-E■■■■■■■■■MINI III ■■, III ■■I A D B ELEpTRIC ® 211 MI■ill EMI 0 REVIEWED FOR DMPUANC NSC H NFPA70 JUL 2 2 2013 Cny . ila BUILDING DIVISION yl..�r■ RV WALL 'A' 1 1 3 HLLVATO\S 1. - A ID B' C REFER TO SHEET E7.O A LOCKERS 104 STORE MGR. A D B ' SUPPLY 103 n 102 BREAK ROOM A .‘14 D B C REFER TO SHEET E7.O B REFER TO _EET E7.0 106 GENERAL MANAGER U J ■ C I • ■ ■ r i U I ■ A B REFER TO SHEET E7.O 105 POS/GEN CL 130 639 BACK OF HOUSE KEY PLAN 1 /4"=l' -o" I U RECEIVED Y OF TUKWILA JUN 282013 RMIT CENTER y L ezt 1-1 LO E , 1-4 U n Cr; Cri M M "• " N a 2 c O E Ii' 0 CO © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 Fax 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM J (I) m zJ -� 3 w OwQ (2zH� wz — U -� Q ZOOS F- co n n 0 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS JNA Drawn Checked Approved BACK OF HOUSE ELECTRICAL ELEVATIONS Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E -8.O 3f_9ff CABLE AND CABLING TRAY PROVIDED INSTALLED BY DAT SUBCONTRACT 1 L f FURRED OUT COLUMN N (N N 1'-11" 1 0 0 0 _\____IDIRTY ^ O I POWER '_\ R 5, k 1 07\ R WALL 'A' HLIVAT ONS (1) 2"0 CONDUIT FOR 25 PAIR PHONE CABLE FROM BUILDING DEMARK — GC COORDINATE ROUTING INSIDE BUILDING PHONE UTILITY AND 110 BLOCK (1) 1/2"0 CONDUIT FOR PHONE CABLES FROM PHONE UTILITY TO SECURITY SYSTEM — GC TO CONFIRM REQUIREMENTS WITH TENANT'S 4ECURITY VENDOR 91 FACT: 11 FAC 1' ADT SECURITY ANTENNA & DIALER PROVIDE CONCEALED ADT , SECURITY ADT ECU.RI1Y CONNECTION TO PHONE UTILITY (2) 20 AMP ISOLATED GROUND DUPLEX OUTLETS WITH TVSS ON UPS GROUND BAR EMERGENCY LIGHTING CONTROL UNITS INSTALLED WITHIN RECESSED JUNCTION BOXES AS SHOWN — WATTSTOPPER ELCU 2000 — PROVIDE BLANK COVER PLATES LABELED 'ELCU' REMOTE TEST STATIONS FOR RTU — TEMP SENSOR OCC. SENSOR/ SWITCH BRACKET MOUNTED FIRE EXTINGUISHER 6 PROVIDE CONCEALED SPACING PLATE c UPS — SUPPLIED BY TENANT AND INSTALLED BY GC WITHIN WALL FRAMING WATER HEATER MTD. ON HOUSEKEEPING PAD FRP PAN ELS WALL SWITCH FOR RECIRCULATING PUMP AND AQUASTAT DISCONNECT SWITCH FOR WATER HEATER CLEANING SUPPLIES r1 II II ! JL I�T11— T-1—r-T�I ILLJ 11 L 1 a- r-1-1-_77-rT1 L1 J—LI—I—L1 14- I 3i A WATER HEATER MTD. ON HOUSEKEEPING PAD WALL 'C WALL 'C' HOOK FOR WIDE STEPSTOOL GFI OPEN TO JANITOR'S CLOSET f WALL 'B 9 SPD DATA WITH (3) DROPS MOUNTED INSIDE POWER WALL —COORDINATE EXACT LOCATION WITH BAS VENDOR PRIOR TO INSTALLATION INTEGRATED POWER SYSTEM (POWER—WALL) FURNISHED BY TENANT INSTALLED BY GC EMERGENCY LIGHTING INVERTER AND BATTERY CABINET — SUPPLIED BY TENANT AND INSTALLED BY GC 2'-7" N ▪ A= 0=7=S an CA 0 t GC C = UPS — SUPPLIED BY TENANT AND INSTALLED BY GC DATA WITH (1) DROP AT WALL FOR UPS UNIT — COORDINATE EXACT LOCATION WITH BAS VENDOR PRIOR TO INSTALLATION IIIIIIIIIIN111111IIUIIIIIIIIIIII 111 lull 1Effilliii 2'-7" Ill!lllllllllllllgllllllllllllIIIII Illuulull IIIIIIgUII IIIIII11uli Illlpulllpum» U1 Illlllllll UIIIIIIIllIiIIIIIIIUllll1111fE 0' HOOKS 7,7 FRP PANEL GFI WALL 'B' WALL 'A' JA\TOH (RV 1 1 1; FL IVATO\S ELFA HANGING/STORAGE AREA T_ SHELVES I ji iI SHORT HANG DIRTY POWER jj Il LONG HANG I I I (i IJ WALL � 9 13'-7 1/2" LOCKERS i rt WALL IRTY 140WER ;' I CD I OPEN TO BREAK ROOM LOC DIRTY POWER 4, � I WALL '8' R Rcov LOCKERS LECT rairrnfretarrn C R00`,/ B i I I •I WALL 'A' 1 1 2) F LHVATO\S ■111-E■■■■■■■■■MINI III ■■, III ■■I A D B ELEpTRIC ® 211 MI■ill EMI 0 REVIEWED FOR DMPUANC NSC H NFPA70 JUL 2 2 2013 Cny . ila BUILDING DIVISION yl..�r■ RV WALL 'A' 1 1 3 HLLVATO\S 1. - A ID B' C REFER TO SHEET E7.O A LOCKERS 104 STORE MGR. A D B ' SUPPLY 103 n 102 BREAK ROOM A .‘14 D B C REFER TO SHEET E7.O B REFER TO _EET E7.0 106 GENERAL MANAGER U J ■ C I • ■ ■ r i U I ■ A B REFER TO SHEET E7.O 105 POS/GEN CL 130 639 BACK OF HOUSE KEY PLAN 1 /4"=l' -o" I U RECEIVED Y OF TUKWILA JUN 282013 RMIT CENTER y L ezt 1-1 LO E , 1-4 U n Cr; Cri M M "• " N a 2 c O E Ii' 0 CO © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 Fax 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM J (I) m zJ -� 3 w OwQ (2zH� wz — U -� Q ZOOS F- co n n 0 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS JNA Drawn Checked Approved BACK OF HOUSE ELECTRICAL ELEVATIONS Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision E -8.O