Loading...
HomeMy WebLinkAboutPermit EL13-1212 - BOEING #9-47.3 - REMODELBOEING #9-47.3 9725 EAST MARGINAL WAY S EL13-1212 Parcel No: Address: Project Name: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 5624200990 9725 E MARGINAL WAY S BLDG 9- 047 BOEING #9-47.3 Permit Number: Issue Date: Permit Expires On: EL13-1212 12/13/2013 6/11/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: DESIMNONE TRUST BOEING 1201 3RD AVE STE 5010 , SEATTLE, WA, 98101 ROLANDO MARTIN 15135 NE 92 ST, REDMOND, WA, 98052 SEQUOYAH ELECTRIC LLC Address: 15135 NE 92ND ST, REDMOND, WA, 98052 License No: SEQUOEL977S9 Lender: Name: Address: Phone: (425) 814-5874 Phone: (425) 814-6000 Expiration Date: 1/29/2015 DESCRIPTION OF WORK: BOEING NCO SIF LAB RELOCATION. PROVIDE AND INSTALL NEW LIGHTING S. Valuation of single family: $0.00 Valuation of mf/comm: $24,672.67 Type of Work: REMODEL Fees Collected: $671.63 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: ) 2 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: /02//3,// ? This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: Tenant Name: C 1.14t,.17-9King Co Asiests Tax No.: 28240490009 9725 East Marginal Way So. B g,-9ft: , 953, 9 iaite Number: Floor: Boeing Company ;,t1ZOPEW,0;054iNtk.,:•:,::-W ':"N,:l.'''.:.',(A':Y:;.::'.:1i!`.-.;,-;.',,,,:_.'.,....:i. ..,_.-.,.,,.._, Name: Boeing Company Address: PO Box 3707 M/C 20-00 City: Seattle State: WA Zip: 98124 ,''''' '''''," -4-,V'''''. "4- • '..." V i' . ',Zkil...ra•jAWeeil.44":10'..toi,,i,-ver:t,..,.,',. ! n , -,.,,•,', l',.,1! .., . ' CONTA CPPERSON,';7iperson,recewmg: ay, projeFt...;•,' '',;. -,It--.,..1'.'1:'' 4:-.1.47:-, •,- ::,....,•.:,',.,.: ,. :lit,' '..".,):, .ji ', • 7..',.,: I(**'..11 4.; t•;1\'•:, - ''',..i'; .i •i'. -i 4: •,,,, .. • ' '' ••• 1,„'" •'•C°Mintillig#4911`;, r ::','"e•Ai- •11`. i'zi: ''',.. 'd ":14...,.'4;•'•: ..'....' •'"A,., '.'1:1t t.• ', A , i • .•,,, . :., , „ Name: Rolando Martin Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Phone: (425) 814-5874 Fax: (425) 814-6003 Email: rolando.martin@sequoyah.com Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Boeing NCO SIF Lab Relocation. Provide and install new lighting and power systems New Tenant: LJ Yes j ..No EL'EotRICAiii.CONTR'AgTokil.NORMATIW: Company Name: Sequoyah Electric Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Phone: (425) 814-6000 Fax: (425) 814-6003 Contr Reg No.: SEQUOEL977S9 Exp Date: 01/29/2015 Tukwila Business License No.: BUS -0100327 Will service be altered? fl Yes 0 No Type of Use: Type o f work: El New 0Addition 0 Low Voltage 0Generator Property Served by: El Puget Sound Energy EZ Seattle City Light Adding more than 50 amps? Yes 0 No El Service Change El Fire Alarm HAApplicationaorins-Applications On Line \2011 ApplicationsTlectrical Pernut Application Revised 0-9-11.doca Revised: August 2011 bh 0 Remodel Ej Telecommunication LI Tenant Improvement Ej Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea O Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) O Service change with added/altered circuits $81.90 number of added circuits $11.55 ea O Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea O Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMI TARPLICATI'ON;;NOTPES;`�; Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 11/26/2013 Print Name: Rolando Martin Day Telephone: (206) 7934957 Mailing Address: 15153 NE 92nd St. Redmond WA 98052 City H:\Applications\Fonts-Applications On Line \2011 Applications\Electrical Permit Application Revised 8.9-I1.docx Revised: August 2011 bh State Zip Page 2 of 2 Cash. Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT 1 QUANTITY PAID $671.63 EL13-1212 Address: 9725 E MARGINAL WAY S BLDG 9-047 Apn: 5624200990 $671.63 ELECTRICAL PLAN CHECK FEE PERMIT FEE MULTI-FAM/COMM TOTAL FEES PAID BY RECEIPT: R210 R000.345.832.00.00 R000.322.101.00.00 $671.63 $134.33 $537.30 $671.63 Date Paid: Wednesday, November 27, 2013 Paid By: SEQUOYAH ELECTRIC LLC Pay Method: CHECK 538860 Printed: Wednesday, November 27, 2013 8:42 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: . 7...y7,3 Type of Inspection:f n Address: 97Z . riAkt‘ Date. Called: Special Instructions: Date Wanted: b _ �` p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date:p ( ob r y • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-1212 DATE: 11/27/13 PROJECT NAME: BOEING #9-47.3 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: i cti. VI' Building Division Public Works Fire Prevention Structural Planning Division nPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/03/13 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IX( REVIEWER'S INITIALS: DATE: Structural Review Required n No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 12/26/13 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 . Fire ❑ Ping 0 PW 0 Staff Initials: SEQUOYAH ELECTRIC LLC • Washington State Department of 4) Labor & Industries 1 Page 1 of 3 SEQUOYAH ELECTRIC LLC Owner or tradesperson NICHOLS, DAVID E Principals NICHOLS, DAVID E Doing business as SEQUOYAH ELECTRIC LLC WA UBI No. 602 252 591 15135 NE 92ND ST REDMOND, WA98052 425-814-6000 KING, County Business type Limited Liability Company Governing persons DAVIDENICHOLS License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. SEQUOEL977S9 Effective — expiration 01/29/2003 — 01/29/2015 Designated administrator NICHOLS, DAVID E License type Master Electrician Bond HARTFORD CAS INS CO Bond account no. 52BSBAB5541 Received by L&I 01/29/2003 Insurance No insurance accounts during the previous 6 year period. Savings No savings accounts during the previous 6 year period. Active. Meets current requirements. ACTIVE License no. NICHODE974O6 $4,000.00 Effective date 01/29/2003 httnc •//secure.l ni _wa_ env/verifv/Detail. asnx?UBI=602252591 &amt:LIC=SEOUOEL977S9&amp:S... 12/13/2013 GROUNDBA FLOOR. C TRANSFOR GROUND G SINGLE 4/0 Cl IN RGS UNDER RAISED NNECTED TO ISOLATION ER AND RASIED FLOOR ID POINT GROUND THWN RISERS TO BASE OF TOWER PEDESTAL GROUNDING CONNECTION (11) PLACES 3E9 E501 IJNDFR RAISFD FI OOR A UNDER RAISED FLOOR TECHNICAL GROUND GRID SEE DETAIL ( 2 1 3E9 E501 1/0 INSULATED STRANDED CU, RAISED FLOOR TWH UNDER SEPARATEIT�EF M T REQUlr ED FOR: b- Mechanical 0 Electrical Plumbing Gas Piping City of Tukwila BUILDING G DIVISION PLATFORM LEVEL GROUNDING P_AN REVISIONS No chane sh Sli hr) made to the scope of io!crl: v^ritho i prier approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR C NIFPA OC N WITH DEC 0 6 2013 119) FILE COPY Permit No. t,), W Pilin review approval is subject to eff0M and omissions. k ..rOVal of construction documents does r v:oiat"ion of any adopted code or ordinancL. 7,-, :4 t CI approved Field Copy and cknowleCg d: BY Dat 1 BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 7 2013 PERMIT CENTER N T7 GROUND BAR - COOPER B -LINE PART #SBTGBK OR APPROVED EQUAL GENERAL NOTES 1. #4/0 BARE COPPER STRANDED WIRE FOR ALL GROUNDING CONDUCTORS, UNLESS NOTED OTHERWISE. 2. GROUNDING CONDUCTOR PIGTAILS WITH A MINIMUM LENGTH OF 10'-0", UNLESS OTHERWISE NOTED. 3. EXOTHERMIC WELDS (CADWELD) FOR ALL CABLE TO GROUND ROD, CABLE TO CABLE AND CABLE TO STRUCTURAL STEEL, UNLESS NOTED OTHERWISE. USE ONLT NEW MOLDS FOR EXOTHERMIC WELDS, AND CHANGE MOLD AFTER 50 CONNECTIONS ARE MADE. 4. PROVIDE GROUNDING CONDUCTORS TO INSTALLED EQUIPMENT USING 3/32"X1/2" BRAID. CONNECT BRAID TO TECHNICAL GROUND GRID. 5. FOR ADDITIONAL INFORMATION SEE DETAILS ON DRAWING E501. 6. PROVIDE FOR COMPLETE ISOLATION BETWEEN EXISTING ITDL GROUND LOOP AND GROUNDING SYSTEM FOR THE TOWER. DO NOT MAKE ANY CONNECTIONS BETWEEN THE TWO SYSTEMS. SEE NOTE 14 ON DRAWING 1 E2. 7. PROVIDE A GROUNDBAR 1"x2"x18" ON THE SOUTH WALL OF THE ROOF EQUIPMENT ROOM. PROVIDE AN INSULATED 4/0 COPPER CONDUCTOR IN CONDUIT CONNECTED TO THE PLATFORM LEVEL UNDERFLOOR TECHNICAL GROUND GRID AT THE SINGLE, COMMON GROUND POINT ONLY. 8. INSTALL GROUND RODS IN SECURITY WELLS AS DETAILED ON DRAWING E504. . 1— AWINGS NT C ON NOTES Or PROVIDE A GROUND BAR INSTALLED 18" ABOVE RAISED FLOOR. PROVIDE #4/0 CU BONDING WIRE TO EXISTING GROUND BAR. PROVIDE #6 CU GROUND BONDING WIRES TO EQUIPMENTS. CONNECT TO FLOOR GROUND BAR. CLEAN AND CONDITION UNDER RAISED FLOOR GROUND BAR. DISCONNECT POWER AND TEST FOR GROUND CURRENT BEFORE DISCONNECTING AND REMOVING EXISTING BONDING WIRES. RECONNECT EXISTING BONDING CONNECTIONS. INSPECT PHYSICAL AND MECHANICAL CONDITION OF THE GROUNDING SYSTEM. GROUNDING SYSTEM SHALL BE FREE OF CORROSION. SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION 4 2 0 2 4 8 li•= --- li• li• _ — SCALE: 1/4" = 1'-0" r SYM REVISION BY APPROVED DATE SYM REVISION A REDRAWN FROM .TIF D. PRETARE F B ISSUED FOR MID DESIGN REVIEW c ISSUED FOR FINAL DESIGN REVIEW D ISSUED FOR CONSTRUCTION E PHASE 3 REV—NOT FOR CONSTRUCTION JEH JEH JEH JEH JMK MJB MJB 6.16.88 7.22.88 8.1.88 11.28.88 G H J ISSUED FOR PHASE 3 CONSTRUCTION RECORD DRAWING NCO SIF RELOCATION — 60% IFR WH_13063 NCO SIF RELOCATION — 80% IFR WH_13063 NCO SIF RELOCATION — IFC WH_13063 W1844093 W1844093 W1844093 BY JEH JEH WH WH WH APPROVED DATE MAS MAS MAS 12.2.88 03.01.08 09.03.13 09.03.13 11.04.13 Q�BOE/NG' ACCEPTABI LITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMUN DATE CHECKED SUBTITLE PLATFORM LEVEL ELECTRICAL GROUNDING SYSTEMS CURRENT REVISION W1844093 SYMBOL j DATE 11.04.13 ENGINEER J. HAMUN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 8.1.88 TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-47.3 COL A -D/1-4 SHEET 3E9 JOB NO. COMP NO. DWG NO. D.C. 9-047-3E9 WAC IAfi CAI TJOHNSTON: 09/03/13 NOTES 1. PROVIDE 1" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND LEGEND OCCUPANCY SENSOR - DUAL TECH LMDC-100 208/120V 480Y/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN 4. PROVIDE LIGHTING FIXTURES IN ACCORDANCE WITH THE LIGHTING FIXTURE SCHEDULE ON DRAWING E502 AND SPECIFICATION SECTION 16510. GENERAL NOTES 5. PROVIDE ROOF MOUNTED PHOTOCELL, FACING NORTH, WITH CONNECTIONS TO LIGHTING CONTACTOR AT PLATFORM LEVEL FOR EXTERIOR LIGHTS. SEE CONTROL CIRCUIT FOR PHOTOCELL AND CONTACTOR ON DRAWING E502. MOUNT CONTACTOR CONTROL ENCLOSURE ON WEST WALL ABOVE TELEPHONE PANEL (COLUMN C-3) AT 8'-0" A.F.F. 6. SEE ADDITIONAL DETAILS FOR LIGHTING INSTALLATION AND CONTROL ON DRAWING E502. REVIEWED .FOR COMPLIANCE WITH NFPA70-NEC DEC 0 6 2013 City of Tukwila BUILDING DIVISION 7. ROUTE ALL CEILING MOUNTED CONDUIT TO CLEAR ACCESS DOORWAY TO ROOF LEVEL EQUIPMENT ROOM. 8. SEE DETAILS ON DRAWING E503 FOR INSTALLATION OF LIGHT FIXTURES ON PLATFORM DOOR SPINDLE. COORDINATE CONDUIT ROUTING WITH STRUCTURAL AND MECHANICAL TRADES FOR ACCESS TO DOOR SPINDLE. DRAWINGS 9. PROVIDE SWITCHES FOR SPINDLE MOUNTED FLOOD LIGHTS (NOTE 8) AND "TEST IN PROGRESS" LIGHT. MOUNT CONTROL BOX ABOVE AT 10'-0" A.F.F. 10. PROVIDE SWITCHED CIRCUIT FOR FLOODLIGHTS ON PLATFORM DOOR SPINDLE. CONNECT TO PANEL AND CIRCUIT BREAKER AS INDICATED. SEE NOTE 9. 11. INSTALL SEPARATE PHOTOEYE FOR OBSTRUCTION LIGHT CONTROL. MOUNT CONTROLLER ON NORTH WALL AT 6'-0" A.F.F. (COLUMN C-2) CONNECT PHOTOEYE, OBSTRUCTION LIGHT AND CONTROLLER AS SHOWN IN DETAIL 1E1 E503 12. »TEST IN PROGRESS" WARNING LIGHT. PROVIDE WIRING FRO GROUND LEVEL TO CONTROL AT PLATFORM. SEE NOTE 9 AN DETAIL t� 1E1 E502 13. RADAR TEST WARNING LIGHT. WIRE TO CONTROLLER FOR CONNECTION TO RADAR TRANSMITTER. SEE DETAIL PROVIDE NEW LIGHT FIXTURE TYPE A. CONNECT TO EXISTING CIRCUITS AND EXISTING CONTROLS. PROVIDE NEW WIRES AND RACEWAY TO COMPLETE THE WORK. PROVIDE NEW LIGHT FIXTURE TYPE A. CONNECT TO EXISTING EMERGENCY CIRCUIT. PROVIDE NEW WIRES. PROVIDE OCCUPANCY SENSOR TIED TO THE LIGHTING CIRCUIT. EXTEND CIRCUIT TO FEED EMERGENCY LIGHTING ON 4TH FLOOR. 1E1I E504 14. INSTALL ALL CEILING MOUNTED LIGHT FIXTURES AT 16'-5" ABOVE RAISED FLOOR LEVEL, UNLESS NOTED OTHERWISE. 15. SEE DRAWING 1E60 FOR RECEPTACLE CIRCUITING. SUPERCEDES IFC SET DATED 09.23.13 <EY PLAN SCALE: NONE FOR CONSTRUCTION SCALE: 1/4" = 1'-0" REVISION APPROVED REVISION APPROVED A REDRAWN FROM .TIF D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION 12.2.88 G RECORD DRAWING 03.01.08 H NCO SIF RELOCATION — 60% IFR WH_13063 NCO SIF RELOCATION — 80% IFR WH_13063 J NCO SIF RELOCATION — IFC WH_13063 W1844093 W1844093 09.03.13 09.11.13 Q�BOE/NG• o'— ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY J. HAMLIN CHECKED PLATFORM LEVEL LIGHTING PLAN CURRENT REVISION W1844093 N N 0 11.04.13 ENGINEER J. HAMLIN CHECKED J.KOKOCZKA W1844093 11.04.13 ELECTRICAL MASTER NCO SIF RELOCATION CO N ao 0 BUILDING 9-47.3 COL. A -D/1-4 JOB NO. DWG NO. COMP NO. 0 j2 9-047-3E10 (AMC IM AAI "nnn Fin 0 A354 PLACES (10) �V4P UP It \I 1 TI I:L0 FIRE ALARM DN ' PA R ' : - III /\\\ • 1 III ♦ 2-2 e -1104 Si LIGHTED SIGN (INSIDE ABOVE DOOR) 'WARNING RF TEST IN PROGRESS" 4 Q y � / e FOR WIRING DETAIL SEE 4 PANEL TC4-2 (REF) TO 4TH FLOOR 3E10 E502 EMERGENCY LIGHTS E — PANEL TC4-3 (REF)1 �\\\UI\\\0IF 111 PANEL TC4-1 (REF) \ III � � ► " _ � iiiiii ��1,�.,:« T., - 1- NOTE 7 TC4-3/2a � LV f \ I(C � � I / III L L \/_i = 11.11 i --I • 46 / \\\ , PANEL XTC4 (REF)''If III E- .` 1-D25 � \i> \ / XTC4/1a u TC4-3/4b NOTE 13 MP) S NOTE 10 / H (4) PLACES 1-15 /\\\ NOTE 9 j-( 11e 4111411 0 _....,„:„.......„_...„......_ - ,...." ii I In OA V eAlii i.i. \\ID NOTE 8 i 11111111 NOTES 1. PROVIDE 1" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND LEGEND OCCUPANCY SENSOR - DUAL TECH LMDC-100 208/120V 480Y/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN 4. PROVIDE LIGHTING FIXTURES IN ACCORDANCE WITH THE LIGHTING FIXTURE SCHEDULE ON DRAWING E502 AND SPECIFICATION SECTION 16510. GENERAL NOTES 5. PROVIDE ROOF MOUNTED PHOTOCELL, FACING NORTH, WITH CONNECTIONS TO LIGHTING CONTACTOR AT PLATFORM LEVEL FOR EXTERIOR LIGHTS. SEE CONTROL CIRCUIT FOR PHOTOCELL AND CONTACTOR ON DRAWING E502. MOUNT CONTACTOR CONTROL ENCLOSURE ON WEST WALL ABOVE TELEPHONE PANEL (COLUMN C-3) AT 8'-0" A.F.F. 6. SEE ADDITIONAL DETAILS FOR LIGHTING INSTALLATION AND CONTROL ON DRAWING E502. REVIEWED .FOR COMPLIANCE WITH NFPA70-NEC DEC 0 6 2013 City of Tukwila BUILDING DIVISION 7. ROUTE ALL CEILING MOUNTED CONDUIT TO CLEAR ACCESS DOORWAY TO ROOF LEVEL EQUIPMENT ROOM. 8. SEE DETAILS ON DRAWING E503 FOR INSTALLATION OF LIGHT FIXTURES ON PLATFORM DOOR SPINDLE. COORDINATE CONDUIT ROUTING WITH STRUCTURAL AND MECHANICAL TRADES FOR ACCESS TO DOOR SPINDLE. DRAWINGS 9. PROVIDE SWITCHES FOR SPINDLE MOUNTED FLOOD LIGHTS (NOTE 8) AND "TEST IN PROGRESS" LIGHT. MOUNT CONTROL BOX ABOVE AT 10'-0" A.F.F. 10. PROVIDE SWITCHED CIRCUIT FOR FLOODLIGHTS ON PLATFORM DOOR SPINDLE. CONNECT TO PANEL AND CIRCUIT BREAKER AS INDICATED. SEE NOTE 9. 11. INSTALL SEPARATE PHOTOEYE FOR OBSTRUCTION LIGHT CONTROL. MOUNT CONTROLLER ON NORTH WALL AT 6'-0" A.F.F. (COLUMN C-2) CONNECT PHOTOEYE, OBSTRUCTION LIGHT AND CONTROLLER AS SHOWN IN DETAIL 1E1 E503 12. »TEST IN PROGRESS" WARNING LIGHT. PROVIDE WIRING FRO GROUND LEVEL TO CONTROL AT PLATFORM. SEE NOTE 9 AN DETAIL t� 1E1 E502 13. RADAR TEST WARNING LIGHT. WIRE TO CONTROLLER FOR CONNECTION TO RADAR TRANSMITTER. SEE DETAIL PROVIDE NEW LIGHT FIXTURE TYPE A. CONNECT TO EXISTING CIRCUITS AND EXISTING CONTROLS. PROVIDE NEW WIRES AND RACEWAY TO COMPLETE THE WORK. PROVIDE NEW LIGHT FIXTURE TYPE A. CONNECT TO EXISTING EMERGENCY CIRCUIT. PROVIDE NEW WIRES. PROVIDE OCCUPANCY SENSOR TIED TO THE LIGHTING CIRCUIT. EXTEND CIRCUIT TO FEED EMERGENCY LIGHTING ON 4TH FLOOR. 1E1I E504 14. INSTALL ALL CEILING MOUNTED LIGHT FIXTURES AT 16'-5" ABOVE RAISED FLOOR LEVEL, UNLESS NOTED OTHERWISE. 15. SEE DRAWING 1E60 FOR RECEPTACLE CIRCUITING. SUPERCEDES IFC SET DATED 09.23.13 <EY PLAN SCALE: NONE FOR CONSTRUCTION SCALE: 1/4" = 1'-0" REVISION APPROVED REVISION APPROVED A REDRAWN FROM .TIF D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION 12.2.88 G RECORD DRAWING 03.01.08 H NCO SIF RELOCATION — 60% IFR WH_13063 NCO SIF RELOCATION — 80% IFR WH_13063 J NCO SIF RELOCATION — IFC WH_13063 W1844093 W1844093 09.03.13 09.11.13 Q�BOE/NG• o'— ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY J. HAMLIN CHECKED PLATFORM LEVEL LIGHTING PLAN CURRENT REVISION W1844093 N N 0 11.04.13 ENGINEER J. HAMLIN CHECKED J.KOKOCZKA W1844093 11.04.13 ELECTRICAL MASTER NCO SIF RELOCATION CO N ao 0 BUILDING 9-47.3 COL. A -D/1-4 JOB NO. DWG NO. COMP NO. 0 j2 9-047-3E10 (AMC IM AAI "nnn Fin LEGEND 1. PROVIDE 3" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND 208/120V 480Y/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN FIRE ALARM NOTE 9 TELEPHONE PANEL LIGHTED SIGN (INSIDE ABOVE DOOR) "WARNING RF TEST IN PROGRESS" FOR WIRING DETAIL SEE DEC 06 2013 3E11 E502 PANEL XTC4 4. PROVIDE LIGHTING FIXTURES IN ACCORDANCE WITH THE LIGHTING FIXTURE SCHEDULE ON DRAWING E502 AND SPECIFICATION SECTION 16510. GENERAL NOTES 5. PROVIDE ROOF MOUNTED PHOTOCELL, FACING NORTH, WITH CONNECTIONS TO LIGHTING CONTACTOR AT PLATFORM LEVEL FOR EXTERIOR LIGHTS. SEE CONTROL CIRCUIT FOR PHOTOCELL AND CONTACTOR ON DRAWING E502. MOUNT CONTACTOR CONTROL ENCLOSURE ON WEST WALL ABOVE TELEPHONE PANEL (COLUMN C-3) AT 8'-0" A.F.F. 6. SEE ADDITIONAL DETAILS FOR LIGHTING INSTALLATION AND CONTROL ON DRAWING E502. 7. ROUTE ALL CEILING MOUNTED CONDUIT TO CLEAR ACCESS DOORWAY TO ROOF LEVEL EQUIPMENT ROOM. 8. SEE DETAILS ON DRAWING E503 FOR INSTALLATION OF LIGHT FIXTURES ON PLATFORM DOOR SPINDLE. COORDINATE CONDUIT ROUTING WITH STRUCTURAL AND MECHANICAL TRADES FOR ACCESS TO DOOR SPINDLE. F= R DRAWI\GS 9. PROVIDE SWITCHES FOR SPINDLE MOUNTED FLOOD LIGHTS (NOTE 8) AND "TEST IN PROGRESS" LIGHT. MOUNT CONTROL BOX ABOVE AT 10'-0" A.F.F. 10. PROVIDE SWITCHED CIRCUIT FOR FLOODLIGHTS ON PLATFORM DOOR SPINDLE. CONNECT TO PANEL AND CIRCUIT BREAKER AS INDICATED. SEE, NOTE 9. 11. INSTALL SEPARATE PHOTOEYE FOR OBSTRUCTION LIGHT CONTROL. MOUNT CONTROLLER ON NORTH WALL AT 6'-0" A.F.F. (COLUMN C-2) CONNECT PHOTOEYE, OBSTRUCTION LIGHT AND CONTROLLER AS SHOWN IN DETAIL 1E1 E503 CO\STRUCTION \OTES 12. "TEST IN PROGRESS" WARNING LIGHT. PROVIDE WIRING FRO GROUND LEVEL TO CONTROL AT PLATFORM. SEE NOTE 9 AND DETAIL t1 1 E 1 I E502 REMOVE AND REPLACE EXISTING LIGHT FIXTURE TYPE A WITH NEW TYPE A. SEE SCHEDULE ON E502 AND 3E10 FOR NEW WORK. REMOVE EXISTING WIRES. RETAIN CONDUIT FOR RE -USE. 13. RADAR TEST WARNING LIGHT. WIRE TO CONTROLLER FOR CONNECTION TO RADAR TRANSMITTER. SEE DETAIL 1E1 E504 14. INSTALL ALL CEILING MOUNTED LIGHT FIXTURES AT 16'-5" ABOVE RAISED FLOOR LEVEL, UNLESS NOTED OTHERWISE. 15. SEE DRAWING 1E60 FOR RECEPTACLE CIRCUITING. RECEIVED CITY OP TUKWILA SUPERCEDES IFC SET DATED 09.23.13 PERMIT CENTER FOR CONSTRUCTION PLATFORM LEVEL LIGHTING PLA\ SCALE: 1/4"=1'-0" <EY PLA\ SCALE: NONE REMOVAL SCALE: 1/4" = 1'-0" REVISION A REDRAWN FROM .TIF BY D. PRETARE APPROVED DATE SYM F G H J REVISION ISSUED FOR PHASE 3 CONSTRUCTION RECORD DRAWING NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH_13063 W1844093 W1844093 W1844093 BY JEH JEH WH WH WH APPROVED MAS MAS MAS DATE 12.2.88 03.01.08 09.03.13 09.11.13 11.04.13 Q�BOE/NG' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN J. HAMLIN CHECKED DATE SUBTITLE DATE ENGINEER J. HAMLIN PLATFORM LEVEL LIGHTING PLAN TRLE NCO SIF RELOCATION CURRENT REVISION W1844093 SHEET SYMBOL j DATE 11.04.13 CHECKED J.KOKOCZKA APPROVED J. BENSTON APPROVED D. O'HARA 8.1.88 ELECTRICAL MASTER BUILDING 9-47.3 COL. A -D/1-4 3EIOR D.C. JOB NO. DWG NO. COMP NO. 9-047-3E1 OR WAC inn AA, 9MA E1A P_ATFORN SCALE: 1/4"=1'-0" LEVEL 208Y/120V POWER PAN LEGE\D L6-30 208V RECEPTACLE, 2 POLE, 3W — WALL MOUNT L21-30 208V RECEPTACLE, 3 POLE, 5W — WALL MOUNT L6-30 t 208V RECEPTACLE, 2 POLE, 3W — FLOOR MOUNT L21-30 208V RECEPTACLE, 3 POLE, 5W — FLOOR MOUNT DUPLEX RECEPTACLE, 5-20R — WALL MOUNT DUPLEX RECEPTACLE, 5-20R — FLOOR MOUNT t QUAD RECEPTACLE, 5-20R — WALL MOUNT * QUAD RECEPTACLE, 5-20R — FLOOR MOUNT 30A, 125V, L5-30 — WALL MOUNT 01) 30A, 125V, L5-30 — FLOOR MOUNT GENERAL NOTES 1. PROVIDE i" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE DEDICATED NEUTRAL TO 120V/1P CIRCUIT. REVIEWED FOR COMPLIANCE WITH NFPA70-NEC . PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. DEC 0 6 2013 'A" PHASE: 'B" PHASE: C" PHASE: EUTRAL EQUIPMENT LEFT BUS IN PANEL CENTER BUS IN PNL RIGHT BUS IN PANEL GROUND 208/120V BLACK RED BLUE WHITE GREEN 480Y/277V BROWN ORANGE YELLOW GRAY REFERENCE D CO\STUCTION NOTES PROVIDE RECEPTACLE AND CIRCUIT AS SHOWN. SUPERCEDES IFC SET DATED 09.23.13 BEY PLA SCALE: NONE FOR CONSTRUCTION SCALE: 1/4" = 1'-0" REVISION REVISION APPROVED A REDRAWN FROM .TIF D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION 12.2.88 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED J. HAMLIN CHECKED SUBTITLE PLATFORM LEVEL 208Y/120V POWER PLAN G RECORD DRAWING 03.01.08 APPROVED BY H NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 J NCO SIF RELOCATION - IFC WH_13063 W1844093 09.03.13 ENGINEER J. HAMLIN NCO SIF RELOCATION CURRENT REVISION W1844093 DATE 11.04.13 CO CHECKED J.KOKOCZKA W1844093 09.11.13 W1844093 11.04.13 ELECTRICAL MASTER BUILDING 9-47.3 COL. A—D/1-4 JOB NO. DWG NO. COMP NO. 0 9-047-3E60 Wit` inn 11A7 'nnn czn CYPHER LOCK WATER HEATER HWH-1 KEYPAD AT 4'-0" SEE SHT. 3M110 A.F.F. 1 AtN6. `TC4-2/20 UP )N ` { I L HEAT TRACE FIRE ALARM 1 a ,- I ._ c9c, PANEL DN { 0) 0) 0 ) � o C- T T TC4-2/18 ' 3/4"C, 2#10 & 1#10 GN44I TC4-2/11a, 3/4" C.O. 13b, 15c 1 Wo ---i ejx 0 1 (TYP) il CYPHER LOCK CONTROLLER 'Il 8 AT 10'-0" A.F.F. Z PANEL TC4-2 (REF) TC4-2/3,5,7 w (---, 2 C1 PANEL TC4-3 (REF) & 621 # GNDr N PANEL TC4-1 (REF) Ail MP) 1111h.. POI • C,i , TC4-2/13,15 I o 1 '-1a " _ • 11 3/4 C, 4#10 L �, J XTC4 (REF) _ 34"CPANEL TC4-2 �1:42:l::5 •,_ TC4-2/17,19 3/4"C 4#10 �` - ��i ,� 3/4"C, 3#1q Q 1#10 GNB :', &# & 1#10 GND (TYP)�) TC4-2/27,29 3/4"C, 4#12 & 1#12 GND (TYP) Alk o2x-e I 111: ..,� .lid AIM I II 1.1\ . 46.... -I ,- / _____-.- P_ATFORN SCALE: 1/4"=1'-0" LEVEL 208Y/120V POWER PAN LEGE\D L6-30 208V RECEPTACLE, 2 POLE, 3W — WALL MOUNT L21-30 208V RECEPTACLE, 3 POLE, 5W — WALL MOUNT L6-30 t 208V RECEPTACLE, 2 POLE, 3W — FLOOR MOUNT L21-30 208V RECEPTACLE, 3 POLE, 5W — FLOOR MOUNT DUPLEX RECEPTACLE, 5-20R — WALL MOUNT DUPLEX RECEPTACLE, 5-20R — FLOOR MOUNT t QUAD RECEPTACLE, 5-20R — WALL MOUNT * QUAD RECEPTACLE, 5-20R — FLOOR MOUNT 30A, 125V, L5-30 — WALL MOUNT 01) 30A, 125V, L5-30 — FLOOR MOUNT GENERAL NOTES 1. PROVIDE i" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE DEDICATED NEUTRAL TO 120V/1P CIRCUIT. REVIEWED FOR COMPLIANCE WITH NFPA70-NEC . PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. DEC 0 6 2013 'A" PHASE: 'B" PHASE: C" PHASE: EUTRAL EQUIPMENT LEFT BUS IN PANEL CENTER BUS IN PNL RIGHT BUS IN PANEL GROUND 208/120V BLACK RED BLUE WHITE GREEN 480Y/277V BROWN ORANGE YELLOW GRAY REFERENCE D CO\STUCTION NOTES PROVIDE RECEPTACLE AND CIRCUIT AS SHOWN. SUPERCEDES IFC SET DATED 09.23.13 BEY PLA SCALE: NONE FOR CONSTRUCTION SCALE: 1/4" = 1'-0" REVISION REVISION APPROVED A REDRAWN FROM .TIF D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION 12.2.88 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED J. HAMLIN CHECKED SUBTITLE PLATFORM LEVEL 208Y/120V POWER PLAN G RECORD DRAWING 03.01.08 APPROVED BY H NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 J NCO SIF RELOCATION - IFC WH_13063 W1844093 09.03.13 ENGINEER J. HAMLIN NCO SIF RELOCATION CURRENT REVISION W1844093 DATE 11.04.13 CO CHECKED J.KOKOCZKA W1844093 09.11.13 W1844093 11.04.13 ELECTRICAL MASTER BUILDING 9-47.3 COL. A—D/1-4 JOB NO. DWG NO. COMP NO. 0 9-047-3E60 Wit` inn 11A7 'nnn czn FIRE ALARM PANEL (REF) NOTES 1. PROVIDE i" E.M.T. CONDUIT ONLY FOR ALL TELEPHONE RUNS, UNLESS NOTED OTHERWISE. 2. PROVIDE RIGID GALVANIZED STEEL CONDUIT FOR TRANSITIONS FROM PVC AT POINTS OF EXIT FROM UNDERGROUND TO EXPOSED RUNS. PROTECT RIGID CONDUIT IN CONCRETE USING BITUMASTIC COATING AS MANUFACTURED BY KOPPERS, SCOTCHRAP #51 TAPE WRAPPING AS MANUFACTURED BY 3M CO. OR OTHER APPROVED METHOD. 3. PROVIDE #12 AWG INSULATED CONDUCTOR OR OTHER APPROVED PULLING CABLE AS A PULL -WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. LEGEND 4. PROVIDE A SINGLE DOOR ENCLOSURE 24"x24"x8" FOR A TELEPHONE CABINET;HOFFMAN #A-242408LP WITH FABRICATED 21"x21"4" PLYWOOD INTERIOR PANEL, PAINTED WHITE. MOUNT BOTTOM OF PANEL AT 4'-0" ABOVE FINISHED (RAISED) FLOOR. BOEING TO PROVIDE TELEPHONE EQUIPMENT AND INSTALLATION INCLUDING SANBAR DEVICES AS REQUIRED FOR ALL TELEPHONE CIRCUITS. GENERAL NOTES H 1/2" C STUB UNDERFLOOR PANEL TC4-2 (REF) PANEL TC4-3 (REF) PANEL TC4-1 (REF) PROVIDE J -BOX WITH LOCKABLE HASP 12"x12"x6" UNDER RAISED FLOOR, AND CONNECTED TO CNC CONDUIT FROM ITDL BUILDING ROOM Y1. PROVIDE HOFFMAN DESIGNLINE #D-L121206LP FOR JUNCTION BOX. (NO SUBSTITUTION) INSTALL DATA CONDUITS INTO PLATFORM LEVEL FLOOR PRIOR TO CONCRETE POUR. COORDINATE WITH STRUCTURAL 8& OTHER TRADES FOR INSTALLATION OF THESE CONDUITS. CONDUITS TO TERMINATE IN INSULATING BUSHINGS AND JUNCTION BOX BETWEEN TRUE FLOOR AND RAISED FLOOR. SEE �1 UE360 E503 REFERENCE DRAWINGS PROVIDE ISOLATION FOR TELEPHONE AND DATA CONDUITS WHERE THEY ARE MOUNTED ON THE TOWER STRUCTURE. INSTALL DIELECTRIC ISOLATION SECTION IN DATA CONDUITS AT ENTRY TO PLATFORM. SEE DETAILS NOTE 5 UE360 E504 UE360 E504 REVIEWED FOR COMPLIANCE WITH NFPA70-NEC DEC 06 2013 INSTALL TELEPHONE FILTER CABINET AND DIELECTRIC ISOLATION SECTION AT TELEPHONE CONDUIT ENTRANCE TO PLATFORM LEVEL. SEE RF FILTER SCHEDULE ON SHT. E504 AND DETAILS UE360 E504 UE360 E504 City of Tukwila BUILDING DIVISION !JUNCTION BOX (NOTE 6) REMOVE EXISTING TELEPHONE CABINET. REMOVE ABANDONED CABLES AND CONDUITS ABOVE AND UNDER THE RAISED FLOOR. REMOVE EXISTING UNDER RAISED FLOOR RECEPTACLES AND CORDS BACK TO SOURCE. (2) EACH 4" DATA CONDUITS (NOTE 6) 12"x12"x4" J -BOX UNDER RAISED FLOOR SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION P_ATFORM LEVEL P_AN SCALE: 1/4"= 1 -0" REMOVAL SCALE: NONE .,-..,igigaggggppggggggg g SCALE: 1/4" = 1'-0" REVISION NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH_13063 ISSUED FOR CONSTRUCTION PHASE 2 REV -NOT FOR CONSTRUCTION W1844093 W1844093 W1844093 BY WH WH WH JEH JEH APPROVED MAS MAS MJB MJB 09.03.13 09.11.13 11.04.13 8.1.88 REVISION ISSUED FOR PHASE 2 CONSTRUCTION PHASE 3 REV -NOT FOR CONSTRUCTION ISSUED FOR PHASE 3 CONSTRUCTION ADDED CMCS CONDUIT RUN RECORD DRAWING BY JEH JEH JEH JEH JEH APPROVED MJB MJB MJB MJB MJB 9.20.88 11.28.88 12.2.88 2.20.89 8.31.89 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN J. HAMLIN CHECKED SUBTITLE DATA CONDUIT & TELEPHONE SYSTEM ENGINEER J. HAMLIN NCO SIF RELOCATION CHECKED J.KOKOCZKA APPROVED J. BENSTON ELECTRICAL MASTER BUILDING 9-47.3 COL. A -D/1-4 CURRENT REVISION W1844093 SYMBOLDATE N 11.04.13 SHEET 3E360R JOB NO. DWG NO. COMP NO. 9-047-3E360R !MAC INA AA7 )n(U1 0117 LIGHTING FIXTURE SCHEDULE 16"X4" FLUORESCENT T5—HO A NORMAL BEAM, CLEAR ACRYLIC WITH WIRE GUARD -3-54W T5—HO 277V PLATFORM LEVEL ROOM LIGHTS —*— 3-54 1X4 FLUORESCENT T5—HO A-1 NORMAL BEAM, CLEAR 2-54W 277V ROOF AREA INTERIOR LIGHTS 2-54 tee- ACRYLIC WITH WIRE GUARD T5—HO 2x4 FLUORESCENT 2—TU:E LITHONIA WA240A-120 WALL PACK HIGH PRESSURE 70 WATT I-0 © 1_70 SODIUM, WEATHER PROOF HIGH PRESS 277V EXTERIOR DOORWAY LIGHTING HOLOPHANE WP2A070HPI2GRFI SODIUM ROTATING BEACON WITH RED 25 WATT TEST INDICATING WARNING <�. 1 LENS, WEATHER PROOF INCAND. 120V LIGHT, SEE DETAILS ON I� 1-25\ EDWARDS 52R—N5 25T8DC E502 AND E503 EXIT LIGHT, UNIVERSAL MOUNT, GREEN LETTERS 25 WATT EXIT LIGHTS 1-02_25 © PRESCOLITE 71222 INCAND.120V SURFACE MOUNT WEATHER— PROOF W/LOW TEMP BALLAST F4OCW 277V OUTSIDE LIGHTS AT TOWER BASE & STAIRWELLS © 2-40 =ID= KENALL 7235-0 WITH 7200A VAPORTIGHT INCANDESCENT 75 WATT 1-32 © 1-75 WITH GLOBE & GUARD INCAND. 120V ELEVATOR PIT LIGHT HUBBELL WC -152 INCANDESCENT FLOODLIGHT 150 WATT © 150 LIGHTWEIGHT SYLVANIA SFL-150—IQ TUNGSTEN HALOGEN 120V SENSOR PLATFORM LIGHTSHO WEATHERPROOF OBSTRUCTION LIGHT, HIGH INTENSITY RED 300 WATT 120V ROOF MOUNTED OBSTRUCTION LIGHT, FLASHER CONTROLLED \ 1 / 0 300 CROUSE—HINDS 40940 INCAND. WITH PHOTOEYE / I \� WEATHERPROOF FLOODLIGHT 300 WATT © 300 WITH ADJUSTABLE MOUNTING HUBBELL QL-505 QUARTZ 120V ROOF BOOM LIGHTINGHO 2—LAMP BALLAST LIGHTING FIXTURE SCHEDULE DETAIL SCALE: NONE LIGHT FIXTURES 2—LAMP BALLAST LAMP 1E11 E502 3E1 RFE10 PRFE10 2—LAMP BALLAST LAMP LV RELAY WITH PILOT CONTACTS (TYP) BLACK (OFF) RED (Oa) BLACK (OFF) GROUND NEUTRA PHASE 2 LAMP BALLAST 277 VAC LIGHTING CIRCUIT 277 VAC JUNCTION BOX RED (ON) WHITE BLUE WHITE >N 0 ° OFF 6-0 6-0 75KVA 277/24V XFMR �-� YELLOW (TYP) WALL SWITCHES jN 0 ° OFF OUTER LAMPS INNER LAMP 24 VDC JUNCTION BOX LOW VOLTAGE LIGHTING CONTROL DETAIL (3� SCALE: NONE E502 LAMINATED SIGN WITH 1 1/2" HIGH ENGRAVED LETTERS //— (NOTE 4) TEST I\ HOGESS WEATHERPROOF JUNCTION BOX ROTATING LIGHT (EDWARDS #52R—N5) 5'-0" ABOVE FINISHED GRADE 1/2" R.G.S. CONDUIT "TEST IN PROGRESS" MOUNTING DETAIL SEE DWG 3E10 FOR LOCATIONS INSTALL LIGHT/SIGN (2) PLACES. (1) CONNECTS TO CKT THIS DWG AS SHOWN (1) CONNECTS TO THE WARNING LIGHT CIRCUIT SEE E502 E504 WARNING RF TEST IN PROGRESS WIRE & CONDUIT RELAY -120 VAC CS1 CS2 THIS CONTACT CCONNECTED TO "WARNING LIGHT" CONTROL TERMINALS SEE E502 E504 NOTE: THIS RELAY T MOUNTED INSIDE 24 VOC JUNCTION BOX DETAIL SCALE: NONE ;7 1E1 3E1 E502 ROTATING LIGHT (EDWARDS #52R—N5) >— 1/2" R.G.S. CONDUIT FOR LIGHT MOUNT • WEATHERPROOF --� JUNCTION BOX LV RELAY WITH — PILOT CONTACTS (TYP) BLACK (OFF) WIRE & CONDUIT X RED (ON) RITE X W xx CONDUIT & WIRE { YELLOW ) X • BLACK BLACK BLUE WHITE —0 o— YELLOW 75KVA 277/24V XFMR NEUTRA PHASE ti WALL MOUNTED CONTROL SWITCH WITH PILOT LIGHT SWITCH, LIGHT & WIRING REMOVED 120 VAC LIGHTING CIRCUIT 120 VAC JUNCTION BOX 277 VAC LIGHTING CIRCUIT 24 VDC JUNCTION BOX 3 CONDUCTOR CABLE W/HUBBELL #HBL5266C PLUG FOR CONNECTION TO USER'S EQUIPMENT SAFETY CIRCUIT SEE USER DWG #SK5NK90292 "TEST IN PROGRESS" LIGHT CONTROL DETAIL (TI� SCALE: NONE 3RFE1E100 3)2 PRFE10 —REVIEWEDFOR H COMPLIANCE NEC NFP DEC 0 6 2013 City ofTD� SIGH BUILDING PHOTOEYE, SPDT MOUNT FACING NORTH (NOTE 1) CONDUIT & WIRING TO ROOF MOUNTED PHOTOEYE NOTES: 1. PROVIDE PHOTOEYE AS MANUFACTURED BY TORK, OR OTHER APPROVED. 2. PROVIDE LOW VOLTAGE RELAYS, SWITCHES AND CONTROLS AS SPECIFIED IN SECTION 16149. 3. SEE PLAN DRAWINGS FOR LOCATIONS OF CONTROLS AND EQUIPMENT SHOWN ON THIS DRAWING. 4. PROVIDE LAMINATED SIGN AS SHOWN. SEE SPECIFICATION SECTION 16195, ELECTRICAL IDENTIFICATION FOR COMPLETE DESCRIPTION OF LAMINATED LABEL STOCK. PROVIDE WHITE LETTERS ON A RED BACKGROUND. LIGHTING CONTACTOR, MECHANICALLY HELD, 20 AMP, 480 VOLT, 3 POLE, 120 VOLT COIL, WITH 3 POSITION SELECTOR SWITCH AND CONTROL TRANSFORMER IN NEMA 1 ENCLOSURE, ALLEN—BRADLEY OR APPROVED. OFF AUTO V ON AUTO OFF 480Y/277 VOLTS 4A N SUPERCEDES IFC SET DATED 09.23.13 120V FUSE ON MOUNT IN COVER 774:Y0 N— CONTROL POWER TRANSFORMER C1- PHOTOEYE LIGHTING CONTROL DETAIL DETAIL SCALE: NONE E502 cpA N N 480Y/277 VOLTS SWITCHED POWER TO LIGHTING FIXTURES RECEIVED CITY OF TUKWILA NOV 2 7 2013 PERMIT CENTER FOR CONSTRUCTION SYM A B C D REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN FROM .11F NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH -13063 D. PRETARE W1844093 W1844093 W1844093 WH WH WH MAS MAS MAS 09.03.13 09.11.13 11.04.13 Q,�BOE/NG' 6' - ACCEPTABILITY THIS DESIGN AND/OR SPECIF1CA110N IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMLIN DATE CHECKED ENGINEER J. HAMLIN SUB11TLE MISCELLANEOUS DETAILS CURRENT REVISION W1844093 SYMBOL DATE D 11.04.13 CHECKED J. KOKOCZKA APPROVED J. BENSTON APPROVED D. 0 HARA 8.1.88 TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-47 DEV. CENTER, WA SHEET E502 JOB NO. COMP NO. DWG NO. 9-047—E502 WAC inn nA7 Inn/1 cA111 TJOHNSTON: 08/30/13 10:50 ROOF 4TH FLOOR t #6 CU TO CABLE TRAY (TYP) e e 0 e GROUND BAR (T'P) � #6 CU TO WORK BENCH (TYP) #6 CU TO ANTENNA/COMM DEVICES (TYP) #4/0 cu—az. RAISED ACCESS FLOOR 0 0 e GROUND BAR az—#4/0 CU< #6 CU TO CABLE TRAY (TYP) #6 CU TO WORK BENCH (TYP) #6 CU TO LAB EQUIPMENT (TYP) PLATFORM LEVEL 3RD FLOOR #4/0 EXISTING t TO EXISTING GROUNDING SYSTEM EXISTING MAIN GROUND BAR GROU\DING RISER 9-47 TOWER (�1 SCALE: NONE RFE360,3E9IE507 LEGEND 0 0 0 B SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION GROUND BAR — COOPER B—LINE PART #SBTGBK OR APPROVED EQUAL GENERAL NOTES REVIEWED FOR COMPLIANCE WITH NFPA70-NEC DEC 06 2013 City of Tukwila BUILDING DIVISION REFERENCE DRAWINGS 0 PROVIDE GROUND BARS, BONDING CONDUCTORS, AND CONNECTION TO EXISTING GROUNDING SYSTEM. RECEIVED CITY OF TUKWILA NOV 2 7 2613 PERMIT CENTER SYM REVISION A B NCO SIF RELOCATION - 60% IFR WH_13063 W1844093 NCO SIF RELOCATION - 80% IFR WH_13063 W1844093 NCO SIF RELOCATION - IFC WH_13063 W1844093 BY WH WH WH APPROVED DATE SYM REVISION BY APPROVED DATE MAS 09.03.13 MAS MAS 09.11.13 11.04.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIRCATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED SUBTITLE ELECTRICAL DETAILS CURRENT REVISION W1844093 SYMBOL DATE 11.04.13 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-47.3 SHEET E507 JOB NO. W1844093 COMP NO. DWG N0. D.C. 9-047—E507 EXOTHERMIC WELD TO GROUND ROD (TYP) DN REVIEWEDO m COMPLIANCE EC NFpp70 DEC 06 2013 rCity of Tukwila DIVISION BUILDING WEATHER/COMM TOWER ELEVATOR GROUND PIGTAIL A U-1 G OUND N AIL MAIN ROOF SYSTEM ROOF LEVEL GROUNDI SCALE: 1/4"=1'-0" \G PLA EL‘ LEGEND FT GROUND BAR - COOPER B -LINE PART #SBTGBK OR APPROVED EQUAL GENERAL \OTES CONS -RU TION \OTES REMOVE AND REPLACE GROUND BAR WITH NEW. RE -CONNECT EXISTING #4/0 CU BONDING WIRE TO THE EXISTING GROUND BAR LOCATED UNDER THE RAISED FLOOR ON PLATFORM (3RD FLOOR) LEVEL. PROVIDE BONDING GROUND WIRE TO CABLE TRAY AND WORK BENCHES. 0 4 e SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION KEY PLAN SCALE: NONE RFE9 , EIVED CITY OF TUKWILA NOV 2 l 2013 SCALE: 1/4" = 1'-0" SYM A REDRAWN FROM .TIF REVISION BY D. PRETARE APPROVED DATE B ISSUED FOR MID DESIGN REVIEW C ISSUED FOR FINAL DESIGN REVIEW D ISSUED FOR CONSTRUCTION E PHASE 3 REV -NOT FOR CONSTRUCTION JEH JEH JEH JEH JMK MJB MJB 6.16.88 7.22.88 8.1.88 11.28.88 SYM F G H REVISION ISSUED FOR PHASE 3 CONSTRUCTION RECORD DRAWING NCO SIF RELOCATION - 60% IFR WH_13063 W1844093 NCO SIF RELOCATION - 80% IFR WH_13063 W1844093 J NCO SIF RELOCATION - IFC WH_13063 W1844093 BY JEH JEH WH WH WH APPROVED DATE MAS MAS MAS 12.2.88 03.01.08 09.03.13 09.11.13 11.04.13 Q�BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. HAMUN DATE CHECKED SUBTITLE ROOF LEVEL GROUNDING PLAN CURRENT REVISION W1844093 SYMBOL J DATE 11.04.13 APPROVED BY DEPT. DATE ENGINEER J. HAMUN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING 9-47.RF ELECTRICAL MASTER COL. A -D/1-4 SHEET RFE9 JOB NO. COMP NO. DWG NO. D.C. 9-047-RFE9 We inn AAs Finn() rnn TJOHNSTON: 08/30/13 09:51 m 111 LU B \ (4) PLACES 2-40 h TO EXISTING EMERGENCY LIGHTING CIRCUIT XTC1 a ON 3RD FLOOR VIA UL 924 TRANSFER Sud ITCH PHOTOEYE (NOTE 5) ROOF LEVEL LIGHTING PLAN SCALE: 1/4"=1'-0" A REVIEWED FOt COMPLIANCE WITH NFPA 70 - NEC DEC 0 5 2013 City of .Tukwila BUILDING DIVISION \OTES 1. PROVIDE I" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND 208/120V 480Y/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN 4. PROVIDE LIGHTING FIXTURES IN ACCORDANCE WITH THE LIGHTING FIXTURE SCHEDULE ON DRAWING E502 AND SPECIFICATION SECTION 16510. 5. PROVIDE ROOF MOUNTED PHOTOCELL, FACING NORTH, WITH CONNECTIONS TO LIGHTING CONTACTOR AT PLATFORM LEVEL FOR EXTERIOR LIGHTS. SEE CONTROL CIRCUIT FOR PHOTOCELL AND CONTACTOR ON DRAWING E502. MOUNT CONTACTOR CONTROL ENCLOSURE ON WEST WALL ABOVE TELEPHONE PANEL (COLUMN C-3) AT 8'-0" A.F.F. 6. SEE ADDITIONAL DETAILS FOR LIGHTING INSTALLATION AND CONTROL ON DRAWING E502. 7. ROUTE ALL CEILING MOUNTED CONDUIT TO CLEAR ACCESS DOORWAY TO ROOF LEVEL EQUIPMENT ROOM. 8. SEE DETAILS ON DRAWING E503 FOR INSTALLATION OF LIGHT FIXTURES ON PLATFORM DOOR SPINDLE. COORDINATE CONDUIT ROUTING WITH STRUCTURAL AND MECHANICAL TRADES FOR ACCESS TO DOOR SPINDLE. 9. PROVIDE SWITCHES FOR SPINDLE MOUNTED FLOOD LIGHTS (NOTE 8) AND "TEST IN PROGRESS" LIGHT. MOUNT CONTROL BOX ABOVE AT 10'-0" A.F.F. $os OCCUPANCY SENSOR SWITCH — MANUAL ON/AUTO OFF DUAL TECH DW -200 GENERAL NOTES AWINGS 10. PROVIDE SWITCHED CIRCUIT FOR FLOODLIGHTS ON PLATFORM DOOR SPINDLE. CONNECT TO PANEL AND CIRCUIT BREAKER AS INDICATED. SEE NOTE 9. 11. INSTALL SEPARATE PHOTOEYE FOR OBSTRUCTION LIGHT CONTROL. MOUNT CONTROLLER ON NORTH WALL AT 6'-0" A.F.F. (COLUMN C-2) CONNECT PHOTOEYE, OBSTRUCTION LIGHT AND CONTROLLER AS SHOWN IN DETAIL 1E E503 12. "TEST IN PROGRESS" WARNING LIGHT. PROVIDE WIRING FROM GROUND LEVEL TO CONTROL AT PLATFORM. SEE NOTE 9 AN DETAIL 13. RADAR TEST WARNING LIGHT. WIRE TO CONTROLLER FOR CONNECTION TO RADAR TRANSMITTER. SEE DETAIL 1E1 E504 14. INSTALL ALL CEILING MOUNTED LIGHT FIXTURES AT 16'-5" ABOVE RAISED FLOOR LEVEL, UNLESS NOTED OTHERWISE. 15. SEE DRAWING 1E60 FOR RECEPTACLE CIRCUITING. SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION R C 0 PROVIDE NEW LIGHT FIXTURE TYPE Al. USE EXISTING CIRCUIT. PROVIDE NEW WIRES AND RACEWAY TO COMPLETE THE WORK. PROVIDE OCCUPANCY SENSOR SWITCH. MANUAL ON/AUTO OFF. PROVIDE EMERGENCY LIGHTING CIRCUIT CONNECTED TO EXISTING CIRCUIT ON PLATFORM LEVEL VIA UL 924 TRANSFER SWITCH BODINE GTD-20A. . RECEVED CITY OF TNKWILA NOV 2 2013 PERMIT (ENTER O RFE10 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" REVISION BY APPROVED DATE SYM REVISION REDRAWN FROM .11F D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION G RECORD DRAWING H NCO SIF RELOCATION — 60% IFR WH_13063 W1844093 NCO SIF RELOCATION — 80% IFR WH_13063 W1844093 J NCO SIF RELOCATION — IFC WH_13063 W1844093 BY JEH JEH WH WH WH APPROVED DATE MAS MAS MAS 12.2.88 03.01.08 09.03.13 09.11.13 11.04.13 ii_AirASPEZAW° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMLIN DATE CHECKED SUBTITLE ROOF LEVEL LIGHTING PLAN ENGINEER J. HAMLIN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING, 9-47.RF ELECTRICAL MASTER COL. A—D/1-4 CURRENT REVISION W1844093 SHEET JOB NO. SYMBOL j RFE10 DWG NO. 9-047—RFE10 WM inn ne1 Wnnn �i n TJOHNSTON: 09/03 m 111 111 LU m 1-r I 111 LU PHOTOEYE (NOTE 5) NOTE 11 ROOF LEVEL LIGHTING PLAN SCALE: 1/4"=1 -0" NOTES 1. PROVIDE 3" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. 208/120V 480Y/277V "A" PHASE: LEFT BUS IN PANEL BLACK BROWN "B" PHASE: CENTER BUS IN PNL RED ORANGE "C" PHASE: RIGHT BUS IN PANEL BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. PROVIDE LIGHTING FIXTURES IN ACCORDANCE WITH THE LIGHTING FIXTURE SCHEDULE ON DRAWING E502 AND SPECIFICATION SECTION 16510. 5. PROVIDE ROOF MOUNTED PHOTOCELL, FACING NORTH, WITH CONNECTIONS TO LIGHTING CONTACTOR AT PLATFORM LEVEL FOR EXTERIOR LIGHTS. SEE CONTROL CIRCUIT FOR PHOTOCELL AND CONTACTOR ON DRAWING E502. MOUNT CONTACTOR CONTROL ENCLOSURE ON WEST WALL ABOVE TELEPHONE PANEL (COLUMN C-3) AT 8'-0" A.F.F. 6. SEE ADDITIONAL DETAILS FOR LIGHTING INSTALLATION AND CONTROL ON DRAWING. E502. 7. ROUTE ALL CEILING MOUNTED CONDUIT TO CLEAR ACCESS DOORWAY TO ROOF LEVEL EQUIPMENT ROOM. 8. SEE DETAILS ON DRAWING E503 FOR INSTALLATION OF LIGHT FIXTURES ON PLATFORM DOOR SPINDLE. COORDINATE CONDUIT ROUTING WITH STRUCTURAL AND MECHANICAL TRADES FOR ACCESS TO DOOR SPINDLE. 9. PROVIDE SWITCHES FOR SPINDLE MOUNTED FLOOD LIGHTS (NOTE 8) AND "TEST IN PROGRESS" LIGHT. MOUNT CONTROL BOX ABOVE AT 10'-0" A.F.F. 10. PROVIDE SWITCHED CIRCUIT FOR FLOODLIGHTS ON PLATFORM DOOR SPINDLE. CONNECT TO PANEL AND CIRCUIT BREAKER AS INDICATED. SEE NOTE 9. 11. INSTALL SEPARATE PHOTOEYE FOR OBSTRUCTION LIGHT CONTROL. MOUNT CONTROLLER ON NORTH WALL AT 6'-0" A.F.F. (COLUMN C-2) CONNECT PHOTOEYE, OBSTRUCTION LIGHT AND CONTROLLER AS SHOWN IN DETAIL 1E1 E503 12. "TEST IN PROGRESS" WARNING LIGHT. PROVIDE WIRING FROM GROUND LEVEL TO CONTROL AT PLATFORM. SEE NOTE 9 AND DETAIL LEGEND GENERAL NOTES REVIEWED .FOR COMPLIANCE WITH NFPA70-NEC DEC 0 6 2013 City of Tukwila BUILDING DIVISION REFERENCE DRAWINGS 0 T 10 OT =S 13. RADAR TEST WARNING LIGHT. WIRE TO CONTROLLER FOR CONNECTION TO RADAR TRANSMITTER. SEE DETAIL 14. INSTALL ALL CEILING MOUNTED LIGHT FIXTURES AT 16'-5" ABOVE RAISED FLOOR LEVEL, UNLESS NOTED OTHERWISE. 15. SEE DRAWING 1E60 FOR RECEPTACLE CIRCUITING. SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION REMOVAL REMOVE EXISTING LIGHT FIXTURE TYPE B. REUSE RACEWAY FOR NEW WORK. REMOVE EXISTING LIGHT SWITCH. REUSE RACEWAY FOR NEW WORK. 1.)Jz O RFE10 RCEIVED CITY F TUKWILA N6V 2 7 2013 PE4IIT CENTER s 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" REVISION REDRAWN FROM .11F BY D. PRETARE APPROVED DATE SYM F REVISION G H J ISSUED FOR PHASE 3 CONSTRUCTION RECORD DRAWING NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH_13063 W1844093 W1844093 W1844093 BY JEH JEH WH WH WH APPROVED MAS MAS MAS DATE 12.2.88 03.01.08 09.03.13 09.11.13 11.04.13 LBOE/NG° o� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMLIN DATE CHECKED SUBTITLE ROOF LEVEL LIGHTING PLAN CURRENT REVISION W1844093 SYMBOL J DATE 11.04.13 ENGINEER J. HAMLIN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING 9-47.RF ELECTRICAL MASTER COL. A -D/1-4 SHEET RFE10R JOB NO. COMP NO. DWG NO. 9-047-RFE1OR WAf' 1AA AA9 'AAA C111 TJOHNSTON: 08/30/13 CONDUIT PENETRATION A WALL EL.=233'-8" (VERI FY) APERTURE PLATFORM #2 SEE ARCH. XTC4/4b TC4-2/9b MOTOR OPERATE DAMPER TC4— DN \ 4" S EVE \9P4 FLOOR WEATHER COMM TOWE ELEVATOR LIGHTING 7a WP PULLBOX 6" Ix6"x 18" PULLBOX 6"x6"x24" 4" CONDUIT 2" IMC POWER CONDUIT 1 '-4'' RADIUS -BENDS PD R SYSTEM APERTURE PLATFORM #1 3" IMC CONDUIT WITH 2'-3" RADIUS BENDS (DATA CONDUIT; REF) ROOF LEVEL POWER PLAN SCALE: 1 /4"=1 —0" A. A REVIEWED FOR H COMPLIANCE 7EC NF DEC 0 6 2013 City of Tukwila BUILDING DIVISION SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION it DUPLEX RECEPTACLE, 5-20R — WALL MOUNT QUAD RECEPTACLE, 5-20R — WALL MOUNT 30A, 125V, L5-30 — WALL MOUNT GENERAL NOTES 1. PROVIDE r EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE DEDICATED NEUTRAL TO 120V/1 P CIRCUIT. 4. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND 208/120V BLACK RED BLUE WHITE GREEN REFERENCE DRAWINGS CO S TI 0 ES 480Y/277V BROWN ORANGE YELLOW GRAY PROVIDE RECEPTACLE AND CIRCUIT AS SHOWN. ILt3421� O RFE60, RECEIVED CITY IOF TUKWILA N9V212013 PER10IT CENTER 4 2 0 2 4 SCALE: 1/4" = 1'-0" 8 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN FROM .11F D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION JEH 12.2.88 G RECORD DRAWING JEH 03.01.08 H NCO SIF RELOCATION - 60% IFR WH_13063 W1844093 WH MAS 09.03.13 NCO SIF RELOCATION - 80% IFR WH_13063 W1844093 WH MAS 09.11.13 NCO SIF RELOCATION - IFC WH_13063 W1844093 WH 11.04.13 e'LAsurze7Aw® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMLIN DATE CHECKED SUBTITLE ROOF LEVEL 208Y/120V POWER PLAN CURRENT REVISION W1844093 SYMBOL DATE 11.04.13 ENGINEER J. HAMLIN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING 9-47.RF ELECTRICAL MASTER COL. A—D/1-4 D.C. SHEET RFE60 JOB NO. COMP NO. DWG NO. 9-047—RFE60 WAC inn AAI IMA cin TJOHNSTON: 08/30/13 10:24 I,r— /� / \ i \� I\�I _ 8»--- / \\ I PULLBOX 6" Ix6"x 18" PULLBOX 6"x6"x24" 4" CONDUIT 2" IMC POWER CONDUIT 1 '-4'' RADIUS -BENDS PD R SYSTEM APERTURE PLATFORM #1 3" IMC CONDUIT WITH 2'-3" RADIUS BENDS (DATA CONDUIT; REF) ROOF LEVEL POWER PLAN SCALE: 1 /4"=1 —0" A. A REVIEWED FOR H COMPLIANCE 7EC NF DEC 0 6 2013 City of Tukwila BUILDING DIVISION SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION it DUPLEX RECEPTACLE, 5-20R — WALL MOUNT QUAD RECEPTACLE, 5-20R — WALL MOUNT 30A, 125V, L5-30 — WALL MOUNT GENERAL NOTES 1. PROVIDE r EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE DEDICATED NEUTRAL TO 120V/1 P CIRCUIT. 4. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND 208/120V BLACK RED BLUE WHITE GREEN REFERENCE DRAWINGS CO S TI 0 ES 480Y/277V BROWN ORANGE YELLOW GRAY PROVIDE RECEPTACLE AND CIRCUIT AS SHOWN. ILt3421� O RFE60, RECEIVED CITY IOF TUKWILA N9V212013 PER10IT CENTER 4 2 0 2 4 SCALE: 1/4" = 1'-0" 8 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN FROM .11F D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION JEH 12.2.88 G RECORD DRAWING JEH 03.01.08 H NCO SIF RELOCATION - 60% IFR WH_13063 W1844093 WH MAS 09.03.13 NCO SIF RELOCATION - 80% IFR WH_13063 W1844093 WH MAS 09.11.13 NCO SIF RELOCATION - IFC WH_13063 W1844093 WH 11.04.13 e'LAsurze7Aw® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMLIN DATE CHECKED SUBTITLE ROOF LEVEL 208Y/120V POWER PLAN CURRENT REVISION W1844093 SYMBOL DATE 11.04.13 ENGINEER J. HAMLIN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING 9-47.RF ELECTRICAL MASTER COL. A—D/1-4 D.C. SHEET RFE60 JOB NO. COMP NO. DWG NO. 9-047—RFE60 WAC inn AAI IMA cin TJOHNSTON: 08/30/13 10:24 CONDUIT PENETRATION A WALL EL.=233'-8" (VER FY APERTURE PLATFORM #2 SEE ARCH. XTC4/4b DN 141- MOTOR OPER TED DAMPER TC4-2/9b TC4— ELEVATOR LIGHTING PULLBOX 6"x6"x18" PULLBOX 6"x6"x24" 2" IMC POWER CONDUIT 1'-4" RADIUS TENDS 3" IMC CONDUIT WITH 2'-3" RADIUS BENDS (DATA CONDUIT; REF) ROOF LEVEL POWER PLAN SCALE: 1 /4"=1'-0" APERTURE PLATFORM #1 A D ED FOr. _gANCE W' 4 -PA 70 - tor- DEC `'' DEC 0 .u13 City of Tukwila .BUILDING DIVISION' LEGEND G E \ E RAL \OTES 1. PROVIDE 4" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: "B" PHASE: "C" PHASE: NEUTRAL EQUIPMENT LEFT BUS IN PANEL CENTER BUS IN PNL RIGHT BUS IN PANEL GROUND 208/120V BLACK RED BLUE WHITE GREEN REFERENCE DRAWINGS CONSTRUCTION NOTES 480Y/277V BROWN ORANGE YELLOW GRAY REMOVE EXISTING ABANDONED WIRES, CABLES, SELECT CONDUITS, AND J—BOXES. REMOVE EXISTING OUTLETS ON SOUTH WALL. REMOVE ASSOCIATED WIRES AND RETAIN EXISTING CONDUIT/PATHWAY FOR RE—USE. ELt3 SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION REMOVAL PAZ O RFE60 .1 RECEIVED CITY OF TUKWILA NOV 272013 !ERMIT CENTER KEY PLAN SCALE: NONE 4 2 0 2 4 8 MIN I=iii • SCALE: 1/4" = 1'-0" REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN FROM .TIF D. PRETARE F ISSUED FOR PHASE 3 CONSTRUCTION JEH 12.2.88 G RECORD DRAWING JEH 03.01.08 H NCO SIF RELOCATION — 60% IFR WH_13063 W1844093 WH MAS 09.03.13 NCO SIF RELOCATION — 80% IFR WH_13063 W1844093 WH MAS 09.11.13 J NCO SIF RELOCATION — IFC WH_13063 W1844093 WH MAS 11.04.13 g)LAirAFEZAW ' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. HAMUN DATE CHECKED SUBTITLE ROOF LEVEL 208Y/120V POWER PLAN CURRENT REVISION W1844093 SYMBOL DATE 11.04.13 APPROVED BY DEPT. DATE ENCINEER J. HAMUN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING 9-47.RF ELECTRICAL MASTER COL. A—D/1-4 D.C. SHEET RFE6OR JOB NO. COMP NO. DWG NO. 9-047—RFE6OR WAC inn net 9AM rl M O TJOHNSTON: 08/30/13 NOTE 3 TC4-3/20a, 22b, 24c TC4-1/3 30 A/3P DISCONNECT /EF\ P07 P02 9 V 00 H GER'. ` (PR EQUIP. PENT USE TC4-3/19a,21 b,23c ELEVATOR 200A/3P DISC (FUSED) ( P03 ) ITC4-1/12 2"C, 3#1+1#6 NOTE 10 TC4-1 /2, 4 30A/3P DISC (NEMA fR) TC4-3/1 a, 3b, 5c ROOF LEVEL POWER PLAN APERTURE PLATFORM #1 SCALE: 1/4"=1 —0" A. REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 6 2013 City of Tukwila BUILDING DIVISION OTES 1. PROVIDE I" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND 208/120V 480Y/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN 4. PROVIDE FUSED OR' NON—FUSED DISCONNECTS AS INDICATED OR AS REQUIRED BY NATIONAL ELECTRIC CODE OR UNIFORM MECHANICAL CODE. 5. PROVIDE 3—PHASE, 480 VOLT MANUAL STARTING SWITCH AS A DISCONNECT FOR UNIT HEATERS AS INDICATED. USE PUSH BUTTON TYPE SWITCHES AS MANUFACTURED BY ALLEN—BRADLEY, BULLETIN 609. IDENTIFY AS SPECIFIED IN SECTION 16195 OF ELECTRICAL SPECIFICATIONS. 6. PROVIDE JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION OF POWER CART. FOR WIRE AND CONDUIT SIZES SEE ONE LINE DIAGRAM ON SHEET E4 & RFE11I E503 7. PROVIDE JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION OF POWER CONVERTER. FOR WIRE & CONDUIT SIZES SEE SHEET E4 & � v � RFE11C E503 8. PROVIDE JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION OF FUTURE POWER CONVERTER. FOR WIRE & CONDUIT SIZES SEE SHEET E4 &e RFE11C E503 9. MOUNT ALL DISCONNECT SWITCHES & CONTROL DEVICES AT 4'-6" A.F.F., UNLESS NOTED OTHERWISE. 10. PROVIDE DISCONNECT SWITCHES FOR AHU-1 AS SHOWN ON DRAWING E4, INCLUDING CONDUIT & WIRING TO PANEL TC4-1, CIRCUITS 2 & 4. PROVIDE NEMA 3R DISCONNECT ENCLOSURES. CONDUIT, WIRE & DISCONNECTS NOT SHOWN FOR CLARITY. LEGEND GENERAL NOTES REFERENCE DRAWINGS 0 T U os REMOVE POWER CART/CONVERTER POWER CONNECTIONS. REMOVE ASSOCIATED WIRES AND CONDUIT BACK TO SOURCE. SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION REMOVAL 4 RECEIVED • CITY OF TUKWILA NOV 2.7 2013 PERMIT CENTER FE11 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" 0 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A REDRAWN FROM .TIF D. PRETARE B NCO SIF RELOCATION — 60% IFR WH_13063 W1844093 WH MAS 09.03.13 C NCO SIF RELOCATION — 80% IFR WH_13063 W1844093 WH MAS 09.11.13 D NCO SIF RELOCATION — IFC WH_13063 W1844093 WH MAS 11.04.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. HAMUN DATE CHECKED SUBTITLE ROOF LEVEL 480Y/277 VOLT POWER PLAN CURRENT REVISION W1844093 SYMBOL D DATE 11.04.13 APPROVED BY DEPT. DATE ENGINEER J. HAMUN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPROVED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING 9-47.RF ELECTRICAL MASTER COL. A—D/1-4 D.C. SHEET RFE110R JOB NO. COMP NO. DWG NO. 9-047—RFE11 OR WAC inn nA7 'nnn 'fl TJOHNSTON: 08/30/13 V —I 4- I/�— /7 / \f/ \./ IX \ r \ 11 NOTE 10 TC4-1 /2, 4 30A/3P DISC (NEMA fR) TC4-3/1 a, 3b, 5c ROOF LEVEL POWER PLAN APERTURE PLATFORM #1 SCALE: 1/4"=1 —0" A. REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 6 2013 City of Tukwila BUILDING DIVISION OTES 1. PROVIDE I" EMT CONDUIT UNLESS OTHERWISE NOTED. 2. PROVIDE #12 AWG COPPER, TYPE THHN/THWN INSULATED WIRE UNLESS NOTED OTHERWISE 3. PROVIDE COLOR CODING OF CONDUCTORS ACCORDING TO THE FOLLOWING TABLE FOR ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE: LEFT BUS IN PANEL "B" PHASE: CENTER BUS IN PNL "C" PHASE: RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND 208/120V 480Y/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN 4. PROVIDE FUSED OR' NON—FUSED DISCONNECTS AS INDICATED OR AS REQUIRED BY NATIONAL ELECTRIC CODE OR UNIFORM MECHANICAL CODE. 5. PROVIDE 3—PHASE, 480 VOLT MANUAL STARTING SWITCH AS A DISCONNECT FOR UNIT HEATERS AS INDICATED. USE PUSH BUTTON TYPE SWITCHES AS MANUFACTURED BY ALLEN—BRADLEY, BULLETIN 609. IDENTIFY AS SPECIFIED IN SECTION 16195 OF ELECTRICAL SPECIFICATIONS. 6. PROVIDE JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION OF POWER CART. FOR WIRE AND CONDUIT SIZES SEE ONE LINE DIAGRAM ON SHEET E4 & RFE11I E503 7. PROVIDE JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION OF POWER CONVERTER. FOR WIRE & CONDUIT SIZES SEE SHEET E4 & � v � RFE11C E503 8. PROVIDE JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION OF FUTURE POWER CONVERTER. FOR WIRE & CONDUIT SIZES SEE SHEET E4 &e RFE11C E503 9. MOUNT ALL DISCONNECT SWITCHES & CONTROL DEVICES AT 4'-6" A.F.F., UNLESS NOTED OTHERWISE. 10. PROVIDE DISCONNECT SWITCHES FOR AHU-1 AS SHOWN ON DRAWING E4, INCLUDING CONDUIT & WIRING TO PANEL TC4-1, CIRCUITS 2 & 4. PROVIDE NEMA 3R DISCONNECT ENCLOSURES. CONDUIT, WIRE & DISCONNECTS NOT SHOWN FOR CLARITY. LEGEND GENERAL NOTES REFERENCE DRAWINGS 0 T U os REMOVE POWER CART/CONVERTER POWER CONNECTIONS. REMOVE ASSOCIATED WIRES AND CONDUIT BACK TO SOURCE. SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION REMOVAL 4 RECEIVED • CITY OF TUKWILA NOV 2.7 2013 PERMIT CENTER FE11 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" 0 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A REDRAWN FROM .TIF D. PRETARE B NCO SIF RELOCATION — 60% IFR WH_13063 W1844093 WH MAS 09.03.13 C NCO SIF RELOCATION — 80% IFR WH_13063 W1844093 WH MAS 09.11.13 D NCO SIF RELOCATION — IFC WH_13063 W1844093 WH MAS 11.04.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. HAMUN DATE CHECKED SUBTITLE ROOF LEVEL 480Y/277 VOLT POWER PLAN CURRENT REVISION W1844093 SYMBOL D DATE 11.04.13 APPROVED BY DEPT. DATE ENGINEER J. HAMUN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPROVED D. 0 HARA 8.1.88 TITLE NCO SIF RELOCATION BUILDING 9-47.RF ELECTRICAL MASTER COL. A—D/1-4 D.C. SHEET RFE110R JOB NO. COMP NO. DWG NO. 9-047—RFE11 OR WAC inn nA7 'nnn 'fl TJOHNSTON: 08/30/13 WEATHER/COMM TOWER A� LANDING 18 NDING 19 REVIEWED FOR COMCE WITH NFPA 0 -NEC DEC 0 6 2013 tV of Tukwila BUILDING DIVISION LEGEND C 1 11 MU £TIO► OU CABLE TRAY COOPER B -LINE PART #FT2X 8X10 OR APPROVED EQUAL GENERAL NOTES 1. PROVIDE i" E.M.T. CONDUIT ONLY FOR ALL TELEPHONE RUNS, UNLESS NOTED OTHERWISE. 2. PROVIDE RIGID GALVANIZED STEEL CONDUIT FOR TRANSITIONS FROM PVC AT POINTS OF EXIT FROM UNDERGROUND TO EXPOSED RUNS. PROTECT RIGID CONDUIT IN CONCRETE USING BITUMASTIC COATING AS MANUFACTURED BY KOPPERS, SCOTCHRAP #51 TAPE WRAPPING AS MANUFACTURED BY 3M CO. OR OTHER APPROVED METHOD. 3. PROVIDE #12 AWG INSULATED CONDUCTOR OR OTHER APPROVED PULLING CABLE AS A PULL -WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. ELEVATOR CONTROLLER ©E4 ► 4• • 5 AFI lr • • to • • • • • • 11 • YIN .4 x (�-) ►� ,I w4111i 4; ..i: 360 E503 y 6" PVC PIPE DATA CABLE ACCESS TO ROOF (3) PLACES RFE360 E505 CONDUIT PENETRATION A WALL EL.=233'-8" (VERIFY) APERTURE PLATFORM #2 SEE ARCH. OSURE 1 WAVEGUIDE PENETRATION SEE DETAIL E� 4" CONDUIT RFE360 E503 CABLE TRAY (2) 4" SLEEVE ARRAY SYSTEM NEMA -4X CABINET 17"W X 14"D X 22"H 2" IMC POW: R CONDUIT 1'-4" RADIU', BENDS (REF) 3" IMC CONDUIT WITH 2'-3" RADIUS BENDS (DATA CONDUIT) 4 ROOF LEVEL PLAN SCALE: 1 /4"= 1'-0" BOOM & BOOM ASSY SEE STRUCT. EXTERIOR MMUNICATIONS PASSAGE CA3INET � SCALE: I NE RFE360 SYM REVISION L M N D E NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH_13063 ISSUED FOR CONSTRUCTION PHASE 2 REV -NOT FOR CONSTRUCTION W1844093 W1844093 W1844093 BY WH WH WH JEH JEH APPROVED DATE MAS MAS MAS MJB MJB 09.03.13 SYM F REVISION BY APPROVED DATE 09.11.13 G 11.04.13 H 8.1.88 J 9.9.88 K ISSUED FOR PHASE 2 CONSTRUCTION PHASE 3 REV -NOT FOR CONSTRUCTION ISSUED FOR PHASE 3 CONSTRUCTION ADDED CMCS CONDUIT RUN RECORD DRAWING JEH JEH JEH JEH JEH MJB MJB MJB MJB MJB 9.20.88 11.28.88 12.2.88 2.20.89 8.31.89 Q�BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMLIN SUPERCEDES IFC SET DATED 09.23.13 LYa- 1)-P- CONSTRUCTION NOTES FOR CONSTRUCTION DATE REFER TO DRAWING E507 DETAILS 1 AND 2 FOR CABLE TRAY SUPPORT DETAILS. REFER TO DRAWING E507 DETAIL 3 FOR CABLE TRAY SUPPORT DETAILS. MOUNT CABLE TRAY 84 INCHES ABOVE FINISHED FLOOR. PROVIDE CONDUIT SLEEVES AND A NEMA -4X CABINET FOR COMMUNICATION CABLES PASSAGE. SEE DETAIL THIS SHEET. -LI --I-H -A - U \� /j ``� F II LA "i8 ROOF UNIT IOP HVAC SEE MECH. / \ r/ \ ==mI N,-- `.A ://CE366# V/ ___t_ OSURE 1 WAVEGUIDE PENETRATION SEE DETAIL E� 4" CONDUIT RFE360 E503 CABLE TRAY (2) 4" SLEEVE ARRAY SYSTEM NEMA -4X CABINET 17"W X 14"D X 22"H 2" IMC POW: R CONDUIT 1'-4" RADIU', BENDS (REF) 3" IMC CONDUIT WITH 2'-3" RADIUS BENDS (DATA CONDUIT) 4 ROOF LEVEL PLAN SCALE: 1 /4"= 1'-0" BOOM & BOOM ASSY SEE STRUCT. EXTERIOR MMUNICATIONS PASSAGE CA3INET � SCALE: I NE RFE360 SYM REVISION L M N D E NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH_13063 ISSUED FOR CONSTRUCTION PHASE 2 REV -NOT FOR CONSTRUCTION W1844093 W1844093 W1844093 BY WH WH WH JEH JEH APPROVED DATE MAS MAS MAS MJB MJB 09.03.13 SYM F REVISION BY APPROVED DATE 09.11.13 G 11.04.13 H 8.1.88 J 9.9.88 K ISSUED FOR PHASE 2 CONSTRUCTION PHASE 3 REV -NOT FOR CONSTRUCTION ISSUED FOR PHASE 3 CONSTRUCTION ADDED CMCS CONDUIT RUN RECORD DRAWING JEH JEH JEH JEH JEH MJB MJB MJB MJB MJB 9.20.88 11.28.88 12.2.88 2.20.89 8.31.89 Q�BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. HAMLIN SUPERCEDES IFC SET DATED 09.23.13 LYa- 1)-P- CONSTRUCTION NOTES FOR CONSTRUCTION DATE REFER TO DRAWING E507 DETAILS 1 AND 2 FOR CABLE TRAY SUPPORT DETAILS. REFER TO DRAWING E507 DETAIL 3 FOR CABLE TRAY SUPPORT DETAILS. MOUNT CABLE TRAY 84 INCHES ABOVE FINISHED FLOOR. PROVIDE CONDUIT SLEEVES AND A NEMA -4X CABINET FOR COMMUNICATION CABLES PASSAGE. SEE DETAIL THIS SHEET. KEY PLAN SCALE: NONE 0 • RECEIVED CITY OF TUKW NOV 2? 2C3 PERMIT CENTE 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" CHECKED SUBTITLE DATA CONDUIT & TELEPHONE SYSTEM CURRENT REVISION W1844093 SYMBOL A DATE 11.04.13 LP R ENGINEER J. HAMLIN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 7.1.88 TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-47.RF COL. A -D/1-4 D.C. _�' RFE360 JOB NO. COMP NO. DWG NO. 9-047-RFE360 WAC IAA AA7 AAAA CA7 TJOHNSTON: 08/30/13 07:53 -LI --I-H ://CE366# V/ ___t_ C ri ' 1 KEY PLAN SCALE: NONE 0 • RECEIVED CITY OF TUKW NOV 2? 2C3 PERMIT CENTE 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" CHECKED SUBTITLE DATA CONDUIT & TELEPHONE SYSTEM CURRENT REVISION W1844093 SYMBOL A DATE 11.04.13 LP R ENGINEER J. HAMLIN CHECKED J.KOKOCZKA APPROVED J. BENSTON APPR9VED D. 0 HARA 7.1.88 TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-47.RF COL. A -D/1-4 D.C. _�' RFE360 JOB NO. COMP NO. DWG NO. 9-047-RFE360 WAC IAA AA7 AAAA CA7 TJOHNSTON: 08/30/13 07:53