Loading...
HomeMy WebLinkAboutPermit EL13-1216 - BOEING #9-82.2 - REMODELBOEING #9-98.2 9725 EAST MARGINAL WAY S EL13-1216 1 City of Tukwila Department of Community Development �v 6300 Southcenter Boulevard, Suite #100 `� Tukwila, Washington 98188 i3 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: Project Name: ELECTRICAL PERMIT 0003400018 9725 E MARGINAL WAY S BLDG 9- 098 BOEING #9-98.2 Permit Number: EL13-1216 Issue Date: 12/13/2013 Permit Expires On: 6/11/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 , SEATTLE, WA, 98124 ROLANDO MARTIN 15135 NE 92 ST, REDMOND, WA, 98052 SEQUOYAH ELECTRIC LLC 15135 NE 92ND ST, REDMOND, WA, 98052 SEQUOEL977S9 111 Phone: (425) 814-5874 Phone: (425) 814-6000 Expiration Date: 1/29/2015 DESCRIPTION OF WORK: BOEING NCO SIF LAB RELOCATION: PROVIDE AND INSTALL NEW LIGHTING AND POWER SYSTEMS Valuation of single family: $0.00 Valuation of mf/comm: $24,672.67 Type of Work: REMODEL Fees Collected: $671.63 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: 12- k 13 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: Print Name: "-oe......6%—i/a//-1/7/'Y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. t L� ?j " 12-1 U' Project No, Date Application Accepted: 0.111P; Expires: Date Application Ex p 21 I 11 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: ,I4i, ?j King Co Assesspr's Tax No.: 28240490009 9725 East Marginal Way So. Bldg. 9,5, 9-53, 9 — "lite Number: Boeing Company PROPERTY OWNER Name: Rolando Martin Name: Boeing Company City: Redmond State: WA Zip: 98052 Address: PO Box 3707 M/C 20-00 Email: rolando.martin@sequoyah.com City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Rolando Martin Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Phone: (425) 814-5874 Fax: (425) 814-6003 Email: rolando.martin@sequoyah.com Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Boeing NCO SIF Lab Relocation. Provide and install new lighting and power systems New Tenant: Floor: ❑ Yes Qf ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Sequoyah Electric Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Phone: (425) 814-6000 Fax: (425) 814-6003 Contr Reg No.: SEQUOEL977S9 Exp Date: 01/29/2015 Tukwila Business License No.: BUS -0100327 lr'I2.41 &) Will service be altered? ❑ Yes 0 No Type of Use: Tyne of work: ❑ New ❑ Addition 0 Service Change 0 Remodel ❑ Tenant Improvement D Low Voltage ❑ Generator ❑ Fire Alarm 0 Telecommunication 0 Temporary Service Adding more than 50 amps? ❑✓ Yes 0 No Property Served by: ❑ Puget Sound Energy ® Seattle City Light H \ Applications \Forms -Applications On Line \2011 Applications \Electrical Pernut Application Reused 8-9.11 doc\ Revised: August 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea O Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea O Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $63.00 O Temporary service (generator) $78.75 O Manufactured/mobile home service $84.00 (excluding garage or outbuilding) O Carnivals $78.75 Number of concessions $10.50 ea PERM ITAPPLICATION .NOTE ,, .';N ".yi, It" ' .« Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: L CSC Date: 11/26/2013 Print Name: Rolando Martin Day Telephone: (206) 7934957 Mailing Address: 15153 NE 92nd St. Redmond WA 98052 City H:\Applications\Fornss-Applications On Line \2011 Applications \Electrical Permit Application Revised 8-9-11.docx Revised: August 2011 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PAID PermitTRAK $671.63 EL13-1216 Address: 9725 E MARGINAL WAY S BLDG 9-098 Apn: 0003400018 $671.63 ELECTRICAL $671.63 PLAN CHECK FEE PERMIT FEE MULTI-FAM/COMM TOTAL FEES PAID BY RECEIPT: R214 R000.345.832.00.00 R000.322.101.00.00 $134.33 $537.30 $671.63 Date Paid: Wednesday, November 27, 2013 Paid By: SEQUOYAH ELECTRIC LLC Pay Method: CHECK 538860 Printed: Wednesday, November 27, 2013 8:46 AM 1 of 1 CRWYSTEMS z INSPECTION RECORD Retain a copiVvith permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: *7_/34., [. �K Type of Inspection: ln� Address: Date Called: ruct Special Ins ions: I C�� 1 D kioN Date Wanted: 10 a. p.m. Requester: �/' evoq Phone No: lac Was, 2112Z pApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: K .y - I b()gill n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Date: INSPECTION RECORD. Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: !� ti a....82 Z Type of Inspection: t Stglj Address: 977.1.0-6 � _ Date Called: Special Instructions:- /1��� tf �nn k Date Wanted: //�/ 3.r- ��- a.r p:m. ((( Requester: kev4 Phone No: Approved per applicable codes: t_J Corrections required prior to approval. COMMENTS: D�' (ft44.cod 6 = Rbu(44 (Ai evir-)a-Te Ppi-dccr Date:. Z 31 13 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. HERMIT COORD COPY 111- PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL13-1216 PROJECT NAME: BOEING #9-98.2 DATE: 11/27/13 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: C =AO (73 Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete DUE DATE: 12/03/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route jk REVIEWER'S INITIALS: DATE: Structural Review Required ri No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 12/26/13 Approved I 1 Approved with Conditions g Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: SEQUOYAH ELECTRIC LLC • 0 Washington State Department of Labor & Industries 1 Page 1 of 3 SEQUOYAH ELECTRIC LLC Owner or tradesperson NICHOLS, DAVID E Principals NICHOLS, DAVID E Doing business as SEQUOYAH ELECTRIC LLC WA UBI No. 602 252 591 15135 NE 92ND ST REDMOND, WA98052 425-814-6000 KING, County Business type Limited Liability Company Governing persons DAVIDENICHOLS License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. SEQUOEL977S9 Effective — expiration 01/29/2003 — 01/29/2015 Designated administrator NICHOLS, DAVID E License type Master Electrician Bond HARTFORD CAS INS CO Bond account no. 52BSBAB5541 Received by L&I 01/29/2003 Insurance No insurance accounts during the previous Savings No savings accounts during the previous 6 6 year period. year period. Active. Meets current requirements. ACTIVE License no. NICHODE97406 $4,000.00 Effective date 01/29/2003 httns://secure.lni.wa. gov/verifv/Detail.astx?UBI=602252591 &amo;LIC=SEQUOEL977S9& S... 12/13/2013 MATCH LINE -FOR CONTIN. _) SEE SHEET 2A11 C1-01 CONFE ENCE CONFEREN E CONFERENCE R 0 VF VF MAI L (±3 CV STORAGE STORAGE 2M11-2 2M11-1 PCTABLE 30X60 NCO OFFIE 2N11-1.3 2M11-3 2N10-1.3 2N10-1.4 TOOLING 2N11-3 2N11-1 2N10-12 2N10-1.1 NCO RECEPT. 2N11-4 /11111111/[1* CAR M GROUND #2/ou MAIN �LDG 2P10-1.3 2P10-1.4 2P11-2 2P11-3 #6 cu To GROUN B 2P11-1.2 2P11 1.1 08L CSL 02L 78C 78C 78C 2R11-1.3 2R11-1. 2R10-1.3 2R10-1.4 +£XOE llLlrll MirElil'Gl*E lraElitt; RE11Alfillii:Gii_ REVIEWED FOR CONEPAMPLIANCE70-ITH NECN DEC 0 6 2013 la DI ! !ON MATCH LINE -FOR CONTIN. SEE SHEET 2A13 PARTIAL 2ND FLOOR GROUNDING PLAN SCALE: 1/8"= 1'—O" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 'SEPARATE PERMIT I kLQUIRED FOR: Mechanical 0 Electrical Plumbing Gas Piping City of Tukwila Bl-i°i,D1NG DIVISION SUPERCEDES IFC SET DATED 09.23.13 LEGEND T T COMMUNICATIONS GROUND BAR — COOPER B—LINE PART #SBTGBK OR APPROVED EQUAL FOR CONSTRUCTION GENERAL NOTES FILA COPY Permit No. tU;— 121(v Plan review approval is subject to errors and omissions, Approval of construction documents does ncy. aLq.!*!•:-Th71 the v:o ation of any adopted code or ordinanc :. ` t;,3, -• of approved Field Copy and conditions is acknowledg uu. By Date: l0 -7/i2 City Of Tukwila BUILDING DIVISION CO S RU TI N \0 -ES PROVIDE WALL MOUNTED GROUND BAR MOUNTED AT 18"AFF. PROVIDE #2/0 BONDING WIRE TO EXISTING BUILDING GROUNDING SYSTEM. PROVIDE BONDING GROUND WIRE. FROM EXISTING BENCH GROUND STRAPS/BAR TO COMM GROUND BAR. PROVIDE BONDING GROUND WIRE FROM CABLE TRAY TO GROUND BAR. ��13-12I1� RECEIVED CITY OF TUKWILA NOV 2 7 2013 PERMIT CENTER KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE 1/8"=1'-0" SYM REVISION NCO SIF RELOCATION — 60% IFR WH_13063 W1844093 A NCO SIF RELOCATION — 80% IFR WH_13063 W1844093 8 NCO SIF RELOCATION — IFC WH_1 3063 W1844093 BY WH WH WH APPROVED DATE SYM REVISION BY APPROVED DATE MAS MAS MAS 09.03.13 09.11.13 11.04.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED SUBTITLE PARTIAL 2ND FLOOR GROUNDING PLAN CURRENT REVISION W1844093 SYMBOL 3 DATE 11.04.13 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-98.2 COL. L—S/1-13 DEV: CENTER, W SHEET 2E9C JOB NO. W1844093 COMP NO. DWG NO. 09-098-2E9C MATCH LINE -FOR CONTIN. SEE SHEET 2A11 0 16b 16t 14a 14a 2E7-5/ 20a,22b 14a #8 22b�DEA il 14a 9b • 12c 2T7-1/ l a,3b,5c #8 2T7-2/ 2a,4b,6c F- — 2T7 -2/7a MATCH LINE -FOR CONTIN. _ SEE SHEET 2A13 ct 0 ,9b 1a 14a16b 36c 16b 3 b 12c 12c #8 2E7-4/34b,36c #8yela 2T7-2/ 8a,10b,12c 8 T7-1/ 1I4a,16b,18c 14a 14a #8 c 2T7-1/ 2a,4b,6c D - # #8 2T7-2/ 2T7-2/ 5c 1 a,3b 2E7 12c � 1 2E62 2E45 /13a,15b, 1a 1/12b 26a 2E62 I 451 2P3/13a 9.111 2P3 2P3/17c 16"BELOW CLG. 2T7-1/7a,9b #10 2T7-1/ 8a,1 0,12c 39b 10 2T7-2/ 37a,39b,41 c 2S6/6c,8a C/1l9a 0 T7=1/ 9a, 1 b 2P3/21b 2P3/16b 22b 10 • 26a #10 2T7-2/ 14a,16b,18c 28b • 18c b 2E6212E452 SEE SHEET 2E6 PARTIAL 2ND FLOOR 208Y/120V POWER P_AN SCALE: 1/8"= V-0" C CONNECTION FOR CARD READER AND/OR ELECTRONIC STRIKE/MAG LOCK. RECEPTACLE FOR DIGITAL CLOCK. LOCATION OF SHIELDING PENETRATION FOR NCO LAB ELECTRICAL PANEL WITH 75A 4W FILTER. 1 4 >LOCATION OF SHIELD PENETRATION FOR STANDBY CIRCUIT FOR ALARM/ACCESS SYSTEMS WITH 20A 2W FILTER. LOCATION OF SHIELDING PENETRATION FOR SST LAB ELECTRICAL PANEL WITH 30A 4W FILTER. OA m t FCI g ._.■ 0 (Di2 2 AC m LEGEND 15A, 125V, 1 20A, 125V, 1 15A, 125V, 1 15A, 125V, 1 WITH GROUND 15A, 125V, 1 15A, 125V, 1 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE PHASE DUPLEX RECEPTACLE PHASE DUPLEX RECEPTACLE (DEDICATED) PHASE, DUPLEX RECEPTACLE FAULT CIRCUIT INTERUPT. PHASE, 4—PLEX RECEPTACLE PHASE, FLOOR MOUNTED DUPLEX PHASE, FLOOR MOUNTED 4—PLEX POWER OR TELEPHONE OUTLET MOUNTED IN DOUBLE BOX MOUNTED IN FLOOR WITH ISOLATED GROUND. 15A, 125V, 1 PHASE, CEILING MOUNTED DUPLEX 30A, 208V, 1 PHASE RECEPTACLE 30A, 208V, 1 PHASE TWIST LOCK RECEPTACLE POWER LINE FILTER 120/208V DISTRIBUTION PANEL SPLIT CHANNEL TELE/POWER POLE. JUNCTION BOX, CEILING/WALL MTD. EQUIPMENT CONNECTION. ABOVE COUNTER MOUNTED FILTER GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. CO\STRUCTION NOTES REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC DEC 0 6 2013 City of Tukwila BUILDING DIVISION SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION ELl3 (IR? RECEIVED CITY OF TUKWILA NOV 2 7 2013 KEY PLAN SCALE: NONE PERMIT CENR 4' 0 4' 8' o 16' IIIII IIIII SCALE 1/8"=1'-0" SYM K B REVISION NCO SIF RELOCATION - IFC WH_13063 W1844093 DCN 1 J#140799-00 C ASI 011 J# 140799-00 D ASI 015 J# 140799-00 E NCO - SST LAB SHIELDING J# 140799-00 BY WH DLR GROUP DLR GROUP DLR GROUP DLR GROUP APPROVED DATE MAS J. BECK 11.04.13 08.24.06 SYM F REVISION RECORD DRAWING 4140799-00 G J. BECK 10.25.06 H J. BECK 02.07.07 D. JOHNS 04.06.07 J INSTALL DUPLEX FOR WALL MTD. TV. NCC RM TABLE OUTLETS NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 12532025 W1576707 W1844093 W1844093 BY DLR GROUP VAVREK ESBROOK WH WH APPROVED DATE J. BECK VAVREK TAE MAS MAS 07.23.07 11.30.11 11.14.12 09.03.13 09.11.13 BOE/iV0° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN EDDIE P. DUARTE DATE 12.11.92 CHECKED SUBTITLE PARTIAL 2ND FLOOR 208Y/120V POWER PLAN CURRENT REVISION W1844093 SYMBOL K DATE 11.04.13 ENGINEER CHECKED R. TUCKER 12.11.92 APPROVED APPROVED NAREN MEHTA 12.11.92 TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-98.2 COL. L -S/1-13 DEV. CENTER, WA SHEET 2E62 JOB NO. COMP NO. DWG NO. 09-098-2E62 TJOHNSTON: 08/28/13 MATCH LINE -FOR CONTIN. _1 SEE SHEET 2A11 LABORATION A CONFE ENCE III CONFERENQE CONi`� E 4 STAIR LOBBY IQ 23L6 54" Q ISI°I _ _ Ott I I rairraimmilM 11 2K3-1.4 21(3-1.3 11 11 -1.1 212-1.2 212-1.3 212-1.4 REVIEWED .FOH COMPLIANCE WITH NEPA 70 - NEC VF VF MAIL -STORAGE 21410- 22L& SIT° 2E362 2E451 CTABLE 30X60 OFFICE OFFI+ E 2N11-1.3 21411-1.4 21410-1.3 21410-1.4 2`41 2112-1.4 2142-1.3 OOLIN 21410-1.2 21410-1.1 111111111111 NEMA 1 ENCL SURE TIP. R�T 21N3 NCO RECEP . 2N11-2.2 2N11-2.1 21410-22 21410-2,1 11 14;111 Ili1� (21 N9 e., CBL an an an 1 an an 1 5J,I gA-1 t 2P11-3 SJR RIDOR 2P10-1,3 2P10-1.4 i� Li 14 FIBER FILTER WITH AVEGU CORRID 111R 23C ASSAGE i212-1.1 2112-1.2 i:3 OPEN OFFICE 2P11-1.2 38L CBL 38L 78C 78C 78C SST LAB 21R7 �-ranra■� �-�r[a��■ 21111-1.3 21110-1.3 2R1D-1.4 CI IMMIRVIP1 ■.•..n:, -'n.,. ,.m. linin ,....r.64+.ria MATCH LINE -FOR CONTIN. SEE SHEET 2A13 BASKET TYPE I 1 CABLE TRAY . (TYP) PARTIAL 2ND FLOOR TELECO SCALE: 1/8"= 1'-0" V1MUNICATIONS P_AN DEC 0 6 2013 City of Tukwila BUILDINGFDIVISIDN LEGEND O SPLIT CHANNEL TELE/POWER POLE. logi TELE/DATA OUTLET, RECESS 4" SQ. BOX WITH SINGLE—GANG MUD RING AND BLANK COVERPLATE N TELEPHONE OUTLET, RECESS SINGLE—GANG BOX WITH MUD RING AND BLANK COVERPLATE. 0 CEILING MOUNTED DATA OUTLET, RECESS 4" SQ. BOX WITH SINGLE—GANG MUD RING AND BLANK COVERPLATE. POWER/DATA FLOOR BOX, TYPE AS NOTED AND SPECIFIED. V m CEILING MOUNTED SPEAKER O JUNCTION BOX 2 EQUIPMENT CONNECTION, CEILING/WALL U S oUI CABLE TRAY COOPER B—LINE PART #FT2X 8X10 OR APPROVED EQUAL GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE 8"X2" BASKET TYPE WIRE CABLE TRAY. PROVIDE SUPPORT SPAN BETWEEN 6'-8' FOR MINIMUM 25LBS/FT LOADING. REFER TO DETAIL 1 SHEET 9-53—E542. EXISTING FIBER PASSAGE METAL PLATE IN CEILING SPACE. PROVIDE NEW (4) WAVEGUIDE WITH 6 CHANNEL. DRILL NEW HOLES TO EXISTING METAL PLATE. COORDINATE EXACT REQUIREMENT IN FIELD WITH BOEING IT. REFER TO SHEET 9-53—E542 DETAIL 3 FOR CABLE TRAY SUPPORT DETAILS. MOUNT CABLE TRAY 12 INCHES BELOW FINISHED CEILING. EXISTING OUTLET SHOWN IN THIS ROOM TO REMAIN. SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION tL\? 121 (0 ? 2E360 RECEIVED CITY OF TUKWILA NOV 2 7 2013 2E363 0 PERMIT CENTER KEY PLAN SCALE: NONE 8' 4' 0 4' 8' SCALE 1/8"=1'-0" 16' SYM A B C REVISION BY APPROVED DATE D 9-98 RENOVATION ADDENDUM 1 J# 140799-00 ASI 011 J# 140799-00 ASI 012 J# 140799-00 RECORD DRAWING J#140799-00 NCO SIF RELOCATION - 60% IFR WH_13063 W1844093 DLR GROUP DLR GROUP DLR GROUP DLR GROUP WH J. BECK J. BECK J. BEECK J. BECK MAS 08.24.06 SYM E 10.25.06 F REVISION NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH_13063 W1844093 W1844093 BY WH WH APPROVED DATE MAS MAS 09.11.13 11.04.13 11.16.06 07.23.07 09.03.13 g)LISFAVEZAW ® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DLR GROUP CHECKED JB DATE 05.10.06 06.27.06 SUBTITLE PARTIAL 2ND FLOOR TELECOMMUNICATIONS PLAN CURRENT REVISION W1844093 SYMBOL F DATE 11.04.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-98.2 COL. L—S/1-13 DEV. CENTER, WA SHEET 2E362 JOB NO. 140799-00 COMP NO. DWG NO. 09-098-2E362 TJOHNSTON: 08/28/13 18:35 O8L b8L O8L 78C 78C 780 n NCO SIF SST AB ENLARGED 208V POWER P_AN 2E62 j 452 SCALE: SCALE: 1/4" = 1 '-0" LEGEND 30A, 125V, L5 -30R it DUPLEX RECEPTACLE 5-20R QUAD RECEPTACLE 5-20R GENERAL NOTES 1. ALL CONDUIT TO BE 3/4" MINIMUM. 2. ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE LEFT BUS IN PANEL) BLACK "B" PHASE CENTER BUS IN PANEL) RED "C" PHASE RIGHT BUS IN PANEL) BLUE NEUTRAL WHITE EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 7. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9. VERIFY ROTATION OF ALL 3 PHASE MOTORS. BROWN ORANGE YELLOW GRAY REFERENCE DRAWINGS CONSTRUCTIO\ NOTES PROVIDE SURFACE MOUNTED DUPLEX FOR ANTENNA TEST RANGE ASSEMBLY. PROVIDE CIRCUIT AS SHOWN. PROVIDE SURFACE MOUNTED QUAD RECEPTACLE. PROVIDE CIRCUIT AS SHOWN. � PROVIDE SURFACE MOUNTED L5-30 RECEPTACLE AND CIRCUIT AS SHOWN. 4 EXISTING RECEPTACLES TO REMAIN. EXISTING PANEL TO REMAIN. PROVIDE NEW CIRCUIT BREAKERS TO COMPLETE THE WORK. REVIEWED FOR COMPLIANCE WIT H NFPA 70 - NEC DEC 0 6 2013 City of Tukwila BUILDING DIVISION SUPERCEDES IFC SET DATED 09.23.13 FOR CONSTRUCTION EL\ I� RECEIVED CITY OF TUKWILA NOV 2 7 2013 PERMIT CENTER 4 2 0 2 4 8 N MI SCALE: 1/4" = 1'-0" SYM REVISION A B NCO SIF RELOCATION - 60% IFR WH_13063 NCO SIF RELOCATION - 80% IFR WH_13063 NCO SIF RELOCATION - IFC WH_13063 W1844093 W1844093 W1844093 BY WH WH WH APPROVED DATE SYM REVISION BY APPROVED DATE MAS MAS MAS 09.03.13 09.11.13 11.04.13 gLAOE/NG' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN T. JOHNSTON DATE 09.03.13 CHECKED M. SANIDAD 09.03.13 SUBTITLE NCO SIF SST LAB ENLARGED 208V POWER PLAN CURRENT REVISION W1844093 SYMBOL DATE 11.04.13 APPROVED BY DEPT. DATE ENGINEER M. SANIDAD 09.03.13 CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER NCO SIF RELOCATION BUILDING 9-98.2 COL. 9 -8/P -S DEV. CENTER, WA SHEET 2E452 JOB NO. W1844093 COMP NO. DWG NO. 9-098-2E452 co 0 TJOHNSTON: 05/29/13