HomeMy WebLinkAboutPermit D14-0006 - SANDBERG RESIDENCE - REMODELSANDBERG RESIDENCE
4928 S 113 ST
D14-0006
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.Qov
3348401741
4928 S 113 ST
Project Name: SANDBERG RESIDENCE
DEVELOPMENT PERMIT
Permit Number:
Issue Date:
Permit Expires On:
D14-0006
5/19/2014
11/15/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
SANDBERG JAMES A
4928 S 113TH ST, TUKWILA, WA,
98178
SHARYN PARKER Phone: (206) 296-7437
7277 PERIMETER RD S , SEATTLE, WA,
98108
G & G SPECIALTY CONTRCTORS INC
4633 S 36 ST, PHOENIX, AZ, 85040
GGSPEGS919RT
FAA (RANRIP)
RESIDENTIAL AIRCRAFT NOISE
REMEDY IMPROVEMENTS PROGRAM,
1 /
Phone: (480) 921-4079
Expiration Date: 12/31/2015
DESCRIPTION OF WORK:
RENOVATION OF SINGLE FAMILY HOME TO REDUCE NOISE INFILTRATION. THE PROJECT INVOLVES UPGRADES
OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINT OR
STRUCTURE. INCLUDES REPLACEMENT OF WINDOWS WITH VINYL -FRAMED ACOUSTICAL WINDOWS,
INSTALLATION OF SECONDARY ALUMINUM -FRAMED SLIDING GLASS STORM DOORS, INSTALLATION OF SWING -
OUT ALUMINUM STORM DOORS, AND INSTALLATION OF CHIMNEY -TOP ACOUSTICAL DAMPERS AT FIREPLACES
AND ATTIC INSTALLATION.
Project Valuation: $36,403.00
Type of Fire Protection: Sprinklers: NO
Fire Alarm: NO
Type of Construction: VB Occupancy per IBC: R-3
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: NONE
Fees Collected: $1,337.30
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition: 2012 International Fuel Gas Code: 2012
International Residential Code Edition: 2012 WA Cities Electrical Code: 2012
International Mechanical Code Edition: 2012 WA State Energy Code: 2012
Uniform Plumbing Code Edition: 2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
rr,, � 1 I'
,
Permit Center Authorized Signature: I i � I Date: _
I hearby certify that I have read and e . d this permit and know the same to be true and correct. All
provisions of law and ordinances gover : his work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name Ki ,�/04ver4eM?4,VL
Date: 1-/t• /7
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A
copy can be obtained at City Hall in the office of the City Clerk.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department`(206-431-3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
0409 FRAMING
0606 GLAZING
0603 ROOF/CEILING INSUL
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
Site Address: 4928 S. 113th St.
Tenant Name:
Name:
Address: 1 `1 ?Q
City: t � (�
�ih State: L, f `� �j Zip: U � Ct3
Name: Sharyn Parker
Address: 7277 Perimeter Road South
City: Seattle
State: WA
Zip: 98108
Phone: (206) 296-7437 Fax: (206) 269-7315
Email: Sharyn.Parker@kingcounty.gov
Company Name: not yet awarded
Address:
City:
State: Zip:
Phone:
Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
King Co Assessor's Tax No.: 3348401741
Suite Number: Floor:
New Tenant: ❑ Yes m..No
ARi H1 ! EGT.0.)[ RE 0ED .. .
Company Name: SM Stemper Architects, PLLC
Architect Name: Timothy Fenlason
Address: 4000 Delridge Way SW, Suite 200
City: Seattle State: WA zip: 98106
Phone: (206) 624-2777 Fax: (206) 624-2973
Email: tenlason@jonespayne.com
EN(
Company Name:
Engineer Name:
Address:
City:
State: Zip:
Phone:
Fax:
Email:
Name: FAA (RANRIP) Residential Aircraft Noise
Address:
Remedy Improvements Program
City:
State: Zip:
HAApplications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 1 of 4
Valuation of Project (contractor's bid price): $ 36,403
Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
Renovation of single-family home to reduce noise infiltration. This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: replacement of
windows with vinyl -framed acoustical windows, installation of secondary aluminum -framed sliding glass storm doors, installation
of swing -out aluminum storm doors, installation of chimney -top acoustical dampers at fireplaces and attic insulation.
Will there be new rack storage? ❑ Yes
14F
0.. No If yes, a separate permit and plan submittal will be required.
Prowl
g Areas in
Existing
1,287
2°a Floor
1,062
3r° Floor
743
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: 2,349 Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes Z No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None
❑ Other (specify) battery sm/CO
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forn s-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 2 of 4
Scope of Work (please provide detailed information):
Ca11 before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
m ...Tukwila ❑...Water District #125
❑ ...Water Availability Provided
Sewer District
m ...Tukwila
❑ ...Sewer Use Certificate
❑ .. Highline
...Valley View ❑ .. Renton
❑...Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Septic System:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apolv):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage)
O ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours
O ...Right-of-way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way ❑
❑ ...Total Cut
0 ...Total Fill
cubic yards
cubic yards
❑ .. Geotechnical Report
❑ .. Maintenance Agreement(s)
❑ ...Traffic Impact Analysis
❑ ...Hold Harmless — (SAO)
0 ...Hold Harmless — (ROW)
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank 0 .. Grease Interceptor
0 ...Cap or Remove Utilities ❑ .. Curb Cut 0 .. Channelization
0 ...Frontage Improvements ❑ .. Pavement Cut 0 .. Trench Excavation
0 ...Traffic Control 0 .. Looped Fire Line ❑ .. Utility Undergrounding
0 ...Backflow Prevention - Fire Protection "
Irrigation "
Domestic Water
0 ...Permanent Water Meter Size... 75 WO #
❑ ...Temporary Water Meter Size .. WO #
O ...Water Only Meter Size 55 WO # 0 ...Deduct Water Meter Size
0 ...Sewer Main Extension Public 0 Private 0
❑ ...Water Main Extension Public 0 Private 0
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
0 ...Water 0 ...Sewer 0 ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:
City
State Zip
Day Telephone:
City
State Zip
H:Wpplications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 3 of 4
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR A . 1 RIZED AGENT:
Signature: i l � Date: 1 qTilt '/o I `t
Print Name: T. othy Fen son Day Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City State Zip
H: Applications\Fornts-Applications On Line \2011 Applications'Permit Application Revised - 8-9-11. docx
Revised: August 2011
bh
Page 4 of 4
t
DESCRIPTIONS
nib
DEVELOPMENT
Cash Register Receipt
City of Tukwila
ACCOUNT
111 111,1 BVll lr
QUANTITY PAID
ato
PERMIT FEE
R000.322.100.00.00
$784.00
PLAN CHECK FEE
R000.345.830.00.00
$509.60
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOt<
.20.
TECHNOLOGY FEE
R000.322.900.04.00
$39.20
pn 3
47400050
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
MENT
$1,070.90'
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
DEVELOPMENT'
897
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$27.06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
DEVELOPMENT'
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11
aSYSTEMS
DESCRIPTIONS
Cash Register Receipt
City of Tukwila
ACCOUNT
QUANTITY
PAID
0
TECHNOLOGY FEE
$31.55
TECHNOLOGY FEE
R000.322.900.04.00
$31.55
D14-
$857.74"
DEVELOPM
2.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE`,
$25,10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
DEVELOPMENT
$1,096.14
PERMIT FEE
R000.322.100.00.00
$661.60
PLAN CHECK FEE
R000.345.830.00.00
$430.04
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$33.08
TECHNOLOGY FEE
R000.322.900.04.00
$33.08
D14-0013 Address: 11870 44 PC S Apn: 3347400790
$957.70
DEVELOPMENT
$929.66
PERMIT FEE
PLAN CHECK FEE
R000.322.100.00.00
R000.345.830.00.00
$560.70
$364.46
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE,
28,04
TECHNOLOGY FEE
R000.322.900.04.00
$28.04
DEVELOPMENT
$1;070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11
CRWYSTEMS
DESCRIPTIONS
Cash Register Receipt
City of Tukwila
ACCOUNT
QUANTITY PAID
DEVELOPMENT
.65
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY: FEE
$31.55
TECHNOLOGY FEE
R000.322.900.04.00
$31.55
D14-0016 Address: 13049 56 AVE S Apn: 2172000060
$1,285.28
DEVELOPMENT
$1,247.61
PERMIT FEE
R000.322.100.00.00
$753.40
PLAN CHECK FEE
R000.345.830.00.00
$489.71
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
37.67
TECHNOLOGY FEE
R000.322.900.04.00
$37.67
LOPMENT' -'
$638.60
PERMIT FEE
R000.322.100.00.00
$384.30
PLAN CHECK FEE
R000.345.830.00.00
$249.80
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY -FEE'
9.22,
TECHNOLOGY FEE
R000.322.900.04.00
$19.22
ME
$1,1T1.88
PERMIT FEE
R000.322.100.00.00
$707.50
PLAN CHECK FEE
R000.345.830.00.00
$459.88
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$35.38
TECHNOLOGY FEE
D14-0019 Address:' 11836 44 AVE S
DEVELOPMENT
R000.322.900.04.00
$35.38
1,323.35
PERMIT FEE
R000.322.100.00.00
$799.30
PLAN CHECK FEE
R000.345.830.00.00
$519.55
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11
CISYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
im IN � 'v"�'r w e
ACCOUNT
t �` ' IN
QUANTITY
PAID
t > 7 44'A1> A� �15 w 3 32
TECHNOLOGY FEE $39.97
TECHNOLOGY FEE
R000.322.900.04.00
$39.97
D14-0020 Address: 1201244 AVE S Apn: 3347401060
857.74
DEVELOPMENT $832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE =
= $25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
p'�Nt
D 14-0021. '' Ac d 't 21 42, AV S Apt.
l;i i,our
3 029 a . 4 3,36
DEVELOPMENT $1,449.57.
PERMIT FEE
R000.322.100.00.00
$875.80
PLAN CHECK FEE
R000.345.830.00.00
$569.27
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE $43.79
TECHNOLOGY FEE
R000.322.900.04.00
$43.79
iMc�)
5 4-0022 r � : 49 5125 5 �F H � 1 � 0 284ti
,259. 8
DEVELOPMENT - $1,222E37
PERMIT FEE
R000.322.100.00.00
$738.10
PLAN CHECK FEE
R000.345.830.00.00
$479.77
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE $36.91
TECHNOLOGY FEE
R000.322.900.04.00
$36.91
D24-0023 l1 2 1 Wdpl: 02,. I ,-
DEVELOPMENT $832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE $25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11
CSYSTEMS
DESCRIPTIONS
DEVELOPMENT
Cash Register Receipt
City of Tukwila
ACCOUNT
QUANTITY
PAID
97.32
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
�27:06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
I• }14'00;
DEVELOPMENT
$1,500.06
PERMIT FEE
R000.322.100.00.00
$906.40
PLAN CHECK FEE
R000.345.830.00.00
$589.16
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
32" :
TECHNOLOGY FEE
R000.322.900.04.00
$45.32
DEVELOPMENT,
PERMIT FEE
R000.322.100.00.00
$462.70
PLAN CHECK FEE
R000.345.830.00.00
$300.76
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$23.14
DEV
TECHNOLOGY FEE
ENT,
R000.322.900.04.00
$23.14
2.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0040 A dress:11664 44. AVE S Apn: 3347400690
DEVELOPMENT
$1,348.59_
PERMIT FEE
R000.322.100.00.00
$814.60
PLAN CHECK FEE
R000.345.830.00.00
$529.49
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11
CRWSYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
dgs
TECHNOLOGY FEE
$40.73
TECHNOLOGY FEE
R000.322.900.04.00
$40.73
M14-0005 Addy* ess:4928 S 113 ST
484017
:MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE'
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
00�
�f7 S
40005
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOtoGY FEE -
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
n 01790C
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.10100.00
$42.56
TECHNOLOGY FEE
$8,51
TECHNOLOGY FEE
MECHANICAL
R000.322.900.04.00
$8.51
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11
CRWYSTEMS
Cash Register Receipt
City of Tukwila
., ,
DESCRIPTIONS
a 6 ' ,'. I ;,f , '1 ..,,,-,4 ',',, ':`,,' -,A,0- , ,", '';i',,i,A;74t4v,o' ,', Nz, --,`, ':.'`;-,r4v4R..;.:r.;,':,-""'"-f-.4"-,
ACCOUNT
"1'.-1,-"' ,-",'''4,-t "tt--,
":" ,'--z.,,",:.
QUANTITY
c.§.•-iiyq', ', ' ',.'''' "tf!..,t,,,,
PAID
- ,-;
,,., ti
,pn:
','
.----': -
,,.,
, m ,KIU , '
.88
',,, 4 1,- --::::, - 14," . .:„.=•:
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
_
$44.98
TECHNOLOGY FEE
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
,-,,,4*,,'. , :ir
' , : ,•9Wo *',) ' -,"
1,
- ''''7
,z,,
'7';
7'' '.
, :,
- ''''
_ ,
$221.3
-'?:*. 7""w".,;-% ,4•N,,,,t,off,&-,,..-
MECHANICAL
- $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
,--
t, t ' -,- , 't, ..v;t:-., t ::',:,-f„c: ::! ' : '.::' q '" ,'' ' '''''' '''', • ,v)F
-.
,
,
,4,,,,,:.:,
0 :‘,/
,,,,, ob ,
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
'''114 4g0111' ' g*„ ,1
,,,I.e.MfM ,4
Apn
5
:-,i'7,:71,.'` '4',4'
M14-00127 • ,,1111010'„7:±.,;"r66'17""1 Address''' '
4 ,
Jo:411,
•,
MECHANICAL: , '',.14.1' ' ' : '. : ,., ,',
'
$21241
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY PEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0A13 Address: 4716 dr-S 122 ST Apn:,3347401455-
-22_
1,32,
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11
CAWSYSTEMS
M14-0013 Address:4
Cash Register Receipt
City of Tukwila
6 S 122 ST
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0014
: 4920 S 114'
221.32
MECHANICAL
$212,81.
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE'
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0016 Add ress:12055 44 AVE S 1 Apn: 3347400420
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100:00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11
ciranwsysTEms
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
)
'
MECHANICAL
ACCOUNT
QUANTITY
PAI D
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOf
$948
TECHNOLOGY FEE
MECHANICAL
R000.322.900.04.00
1
ti
$9.48
$21281
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
MECHANICAL
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
7ECHNOLOGY'FEE
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
MECHANICAL';
$23694
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$948
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0022 Address;
Apn: 017`9000841
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11
cl?IPlfSYSTEMS
Cash Register Receipt
City of Tukwila
ress:1223146 AVE'
n: 01790
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
MECHANICAL
$224,88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.o0
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0025 Address:1300757THAVE S Apn: 2137000020
88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
$8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11
CI` SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
Per
ACCOUNT
QUANTITY
PAI D
14-1
0
Address:11664:1
AVE S
Apn: 3347400690
$233.88
MECHANICAL
$22488
PERMIT ISSUANCE BASE FEE
PERMIT FEE
PLAN CHECK FEE
R000.322.100.00.00
R000.322.100.00.00
R000.322.102.00.00
$32.50
$147.40
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R1222
R000.322.900.04.00
$9.00
$30,413.70
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11
CRWYSTEMS
INSPECTION RECORD
Retain a copy with permit
N NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 - (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Pr t:
Type of I spection:
Addis Cam.)
l 1 g
Date Called:
Special instructions:
Date Wed:-
t
Requester:
Phone No:
Approved per applicable codes.
ElCorrections required prior to approval.
COMMENTS:
6-L4
b
REIN ' ECTION FEE REQUIRE
paid t 6300 Southcenter Blvd..
D
"2—iy
next inspection: fee must be
. Call to schedule reinspection.
-ERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D14-0006 DATE: 01/10/2014
PROJECT NAME: Sandberg Residence
SITE ADDRESS: 4928 S 113 St
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
.c' d ts- H1-1
Building Division M.
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 01/14/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
DUE DATE: 02/11/14
Approved with Conditions
Corrections Required — Denied
(corrections entered in Reviews)
Notation:
(ie: Zoning Issues)
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
G & G SPECIALTY CONTRCTOP INC
Page 1 of 2
4:16) Washington State Department of
Labor & Industries
G & G SPECIALTY CONTRCTORS INC
Owner or tradesperson
GOODBALLET, JAMES SCOTT
Principals
GOODBALLET, JAMES SCOTT, PRESIDENT
GOODBALLET, TERESA LYNN, SECRETARY
GOODBALLET, CHARLES ELMER, CHIEF
EXECUTIVE OFFICER
WAVY, CHRISTINE, CHIEF OPERATING
OFFICER
Doing business as
G & G SPECIALTY CONTRCTORS INC
WA UBI No.
602 975 812
Parent company
G & G SPECIALTY CONTRCTORS INC
1221 N. Monde! DR
GILBERT, AZ85233
480-921-4079
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
GGSPEGS919RT
Effective — expiration
12/31 /2009-12/31 /2015
Bond
HARTFORD FIRE INS CO
Bond account no.
59BSBEA9058
$12,000.00
Received by L&I Effective date
01/03/2011 12/18/2010
Bond history
Insurance
National Union Fire Ins of PA $1,000,000.00
Policy no.
xnd0055800
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014
KI • TY I RNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00860C13 BID PACKAGE M-43
3-53-0058-047
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
ALL INFORI'1ATION IN THE DRAWINGS AND
MECHSPECIFICATIONS I NCLUDING BUT NOT LVENTILATION. THE IMITED TCT O:
APPLICABLE
YES NO
I. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
X
9. INSTALLATION OF FIREPLACE FRESH AIR VENT.
10. INSTALLATION OF CHIMNEY CAP.
X
II. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
IS. INSTALLATION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL PANEL / SERVICE.
X
20. KNOB AND TUBE WIRING.
X
SEPARATE': FEC-.1.41T
REQU RED ;70R:
Mechanical
Electrical
numbing
0 Gas Piping
C.y 3 "!.i'f !a
BLfll. : is .,•::t i`d
F LEC!PY
Permit No. 101 Ii'\ .-O(
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the vio!ation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By
City Of lbkwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES: �'�
l'errInternational Residential Code,
International Fire Code,
International Mechanical Code
3348401141
LEGAL DESCRIPTION:
PARCEL A: THAT PORTION OF LOT(5)159, BLOCK 11, CD HILLMAN'S MEADOW GARDENS ADDITION TO THE. CITY OF SEATTLE, DIVISION
NO 2, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 OF PLATS, PAGE(S) 82, RECORDS OF KING COUNTY, WASHINGTON,
LYING SOUTHERLY OF A LINE WHICH IS PARALLEL TO AND 145 FEET SOUTHERLY, MEASURED AT RIGHT ANGLES, FROM THE NORTHERLY
LINE OF SAID LOT 159, EXCEPT THAT PORTION DESCRIBED AS FOLLOWS± BEGINNING AT A POINT ON THE EASTERLY LINE OF SAID LOT
WHICH IS 35 FEET NORTHERLY OF THE SOUTHEAST CORNER THEREOF, THENCE CONTINUING NORTHERLY ALONG SAID EASTERLY LINE 25
FEET, THENCE WESTERLY AT RIGHT ANGLES 5 FEET, THENCE SOUTHERLY PARALLEL WITH SAID EASTERLY LINE 25 FEET, THENCE
EASTERLY AT RIGHT ANGLES 5 FEET TO THE POINT OF BEGINNING
PARCEL B: THE EASTERLY 60 FEET OF LOT 158, BLOCK 11, CD HILLMAN'S MEADOW GARDEN ADDITION TO THE CITY OF SEATTLE,
DIVISION NO 2, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 OF PLATS, PAGE(S) 82, RECORDS OF KING COUNTY,
WASHINGTON, AS MEASURED PARALLEL WITH SAID EASTERLY LINE OF THAT PORTION LYING SOUTHERLY OF SAID NORTHERLY 120 FEET,
AND EXCEPT PORTIONS CONDEMNED FOR STREET UNDER KING COUNTY SUPERIOR COURT CAUSE NO 26632 SITUATE IN THE COUNTY OF
KING, STATE OF WASHINGTON
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
ciw
City of U wiIa
BUILDING iSION
y011 N96G
DRAWING INDEX
TO.0 TITLE SHEET, PROJECT INFO.
41.0 FLOOR PLANS 4 NOTES
ALI FLOOR PLANS 4 NOTES
A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS
A2.I WINDOW TYPES, SCHEDULE 4 DETAILS
A22 DOOR TYPES, SCHEDULE 4 DETAILS
A23 MISCELLANEOUS DETAILS
42.4 WINDOW FLASHING DETAILS
MI.O LEGENDS, SCHEDULES, ABEREV., GENERAL NOTES 4 DWG INDEX
M2.0 MECHANICAL PLANS AND DETAILS
EI.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E-mail: Sharyn.Parker*1ngcounty.gov
ARCHITECT:
SM. Stemper Architects PLL.C.
4000 Deiridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody
LeungE-mail: Jerryesmstemper.com
melodyesmstemper.com
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Alt Ailaoua
E-mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206.318.0641
Contact: Dylan Turner
E-mail: DylanTegreenbusd-tcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 153. 412. 3300
Fax: 153. 412. 3463
Contact: Brent Rollins
E-mail: bcretreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E-mail: tim ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 0200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: tfenlasonejonespayne.com
CMa eda eJonespa yne.com
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206.622.0422
Contact: Ron Martinson
E-mail: ronmepsm-engineere.com
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review f2ss.
VICINITY MAP (NTS)
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824-2777 • FAX (208) 824-2973
0810.03.2531
AUGUST 19, 2013
0
a_
ce
J
z
0
z
w
>-
z
0
0
z
MPROVEMENTS
>-
cw
w
w
0
z
u_
Li!
RECEIVED
CiTY OF TUKWILA
JAN 0 9 2014
PERMIT CENTER
AIP NUMBE
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
10Q% CD
PROJECT ARCHITECT
JQ
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
TO.O
0810.03.2531
t
SPECIAL NOTES:
I. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT
WERE PRESENT PRIOR TO CONSTRUCTION.
2. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 0111 01 AND 02 82 00 FOR
REGULATED MATERIALS ABATEMENT.
3. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 it 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
4. THIS RESIDENCE HAS EXISTING WIDE INTERIOR TRIM. NEW TRIM TO
MATCH EXISTING INTERIOR TRIM PROFILE. REFERENCE 4/A23 FOR PHOTOS.
5. REFERENCE 5/423 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
FUR
ME CI-IANICAL
LOWER FLOOR PLAN
1/4" = 1'
'
} L .JI..,1 1
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT POOR OR WINDOW 15 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON NE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
S. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING A5 REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT NE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
IS. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM.
".01146.;i:3
A. EAST ELEVATION
DINING
ROOM
PAT O
PATI O
1
41•P 000
B. SOUTH ELEVATION
C
A
MAIN FLOOR PLAN
1/4" = 1'
PLAN KEYNOTES
OI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE.
DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
OSTORM DOOR. REF: DOOR SCHEDULE. REMOVE AND RE -INSTALL (E) EXTERIOR DOOR TREATMENT.
0 REMOVE (E) GARDEN 50X WINDOW, INSTALL ACOUSTICAL GARDEN BOX WINDOW ASSEMBLY. REF: WINDOW SCHEDULE.
OINSTALL NEW EXTERIOR SECONDARY SLIDING GLASS DOOR. REF: DOOR SIMEMBEAND RE -INSTALL (E) EXTERIOR DOOR TREATMENT.
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL INSULATED GLASS UNIT ASSEMBLY. REF: WINDOW SCHEDULE.
ODEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: I/A23 FOR DETAIL. REF: MECHANICAL DOCUMENTS.
O COORDINATE WALL GRILL WITH MECHANICAL DOCUMENTS. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF: MECHANICAL
DOCUMENTS FOR INSTALLATION DETAIL.
OCOORDINATE INSTALLATION OF NEW THERMOSTAT WITH MECHANICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. WEST ELEVATION
LIVING
ROOM
(E) WOOD STOVE.
•
PATIO
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
D. NORTH ELEVATION
LEGEND
ACOUSTICAL WINDOW
A
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR/ STORM DOOR
REFER TO DOOR SCI-IEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PH0T0 VIEW
NEW THERMOSTAT
TIMER SWITCH FOR BLENDED AIR UNIT
rrr m rrrTr m
u-Iw111 1w
E_�
K=1
E-�
1;1;71
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
GAS
ATTIC INSULATION
ATTIC INSULATION DAM
INSTALL BATTERY OPERATED SMOKE
DETECTORS
INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER RECEIVED
CITY OF TUKW
NEW SOFFIT
CEILING PATCH WORK PERMIT CENT
JAN 092014
LA
E
R
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
AUGUST 19, 2013
0810.03.2531
I--
O
a
J
Q
Z
Z
W
Z
0
Ct
Z
0
U
t9
Z
AIP NUMBER
MPROVEMENTS
0
LLB
LU
LU
0
z
1--
LL
C.)
LU
3-53-0058-047
z
0
0
z
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
AI.O
0810.03.2531
1
SPECIAL NOTES:
I. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT
WERE PRESENT PRIOR TO CONSTRUCTION.
2. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR
REGULATED MATERIALS ABATEMENT.
3. LEAD FAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
4. THIS RESIDENCE HAS EXISTING WIDE INTERIOR TRIM. NEW TRIM TO
MATCH EXISTING INTERIOR TRIM PROFILE. REFERENCE 4/A23 FOR PHOTOS.
5. REFERENCE 5/A23 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WOR< DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL NAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
II. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM.
r
'Aligiafkir
A. EAST ELEVATION
O O
1
L.
BEDROOM
2
L_
ta-
CLOSET
•
I
CLOSET
SITTING
ROOM
11-H000(0
B. SOUTH ELEVATION
UPPER FLOOR PLAN
—J
BATI-1
CLOSET
J
1/4" = 1'
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE.
DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
OSTORM DOOR REF: DOOR SCHEDULE. REMOVE AND RE -INSTALL (E) EXTERIOR DOOR TREATMENT.
OREMOVE (E) GARDEN SOX WINDOW, INSTALL ACOUSTICAL GARDEN BOX WINDOW ASSEMBLY. REF: WINDOW SCHEDULE.
OINSTALL NEW EXTERIOR SECONDARY SLIDING GLASS DOOR REF: DOOR SfSIEI i1EEIND RE -INSTALL (E) EXTERIOR DOOR TREATMENT.
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL INSULATED GLASS UNIT ASSEMBLY. REF: WINDOW SCHEDULE.
ODEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: I/A23 FOR DETAIL. REF: MECHANICAL DOCUMENTS.
O COORDINATE WALL GRILL WITH MECHANICAL DOCUMENTS. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF: MECHANICAL
DOCUMENTS FOR INSTALLATION DETAIL.
OCOORDINATE INSTALLATION OF NEW THERMOSTAT WITH MECHANICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. WEST ELEVATION
BEDROOM
4
T
/I\
// I \\
7-
7 O
J
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
D. NORTH ELEVATION
1
J
LEGEND
❑XLI
❑3
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR/ STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
NEW THERMOSTAT
TIMER SWITCH FOR BLENDED AIR UNIT
rRmrrirrm
UIW111uW
E-�
=�
girl]
unau
• :_
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
:'CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
:..k 1 REF. MECH. 4 ELECT.
'.I REF. GENERAL NOTE 11
GAS
ATTIC INSULATION
ATTIC INSULATION DAM
INSTALL BATTERY OPERATED SMOKE
DETECTORS
INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER
NEW SOFFIT
CEILING PATCH WORK
RECEIVED
CITY OF TUKWI
JAN 092014
PERMIT CENTE
L
A
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
TEM
AUGUST 19, 2013
0810.03.2531
0''�
EL
J
z
0
Q
z
Ct
>-
z
0
U
z
AIP NUMBER
MPROVEMENTS
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1.1
0810.03.2531
WINDOW TYPES
1. 2.
FIXED SLIDER/ FIXED/ SLIDER
UJ/ GRIDS
f
3.
GARDEN
4.
HORIZONTAL
XX SLIDER
i
5.
FIXED FIXED/ CASEMENT DOUBLE -HUNG FIXED
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
LIVING ROOM
I
10" x 4'-10"
STAIN/STAIN
SAFETY GLAZING REQ'D, INSULATED GLASS UNIT REPLACEMENT
1/A2.0
B
DINING ROOM
2
10'-0" x 4'-10"
STAIN/STAIN
SAFETY GLAZING REQ'D
1/42.0
C
KITCHEN
3
3'-9" x 2'-10" x I'-4"
STAIN/STAIN
SAFETY GLAZING REQ'D, GARDEN WINDOW
2/A2.0
D
STUDY
1
2'-5" x 2'-5"
STAIN/STAIN
1/A2.0
E
STUDY
4
3'-0" x 2'-8"
STAIN/STAIN
SAFETY GLAZING REQ'D
1/A2.0
F
BEDROOM 1
4
2'-6" x I'-2"
STAIN/STAIN
1/42.0
G
BEDROOM I
4
2'-II" x 3'-II"
STAIN/STAIN
SAFETY GLAZING REQ'D
3/A2.0
H
LIVING ROOM
1
I'-10" x 4'-10"
STAIN/STAIN
SAFETY GLAZING REQ'D
2/A2.1
1
LIVING ROOM
5
3'-I0" x 4'-10"
STAIN/STAIN
SAFETY GLAZING REQ'D
2/A2.1
J
LIVING ROOM
6
I'-10" x 4'-10"
STAIN/STAIN
2/A2.1
K
BEDROOM 2
4
3'-4" x 2'-9"
STAIN/STAIN
3/A2.1
L
BEDROOM 2
1
2'-4" x 4'-5"
STAIN/STAIN
SAFETY GLAZING REQ'D
1/42.0
M
SITTING ROOM
8
2'-11" x 3'-2" x 4'-I0"
STAIN/STAIN
SAFETY GLAZING REQ'D
NEW 6X6 HEADER REQUIRED REF: 6A23 FOR FRAMING DETAIL
I/A2.1
N
SITTING ROOM
1
I'-l" x 4'-8"
STAIN/STAIN
SAFETY GLAZING REQ'D
1/A2.0
0
SITTING ROOM
1
I'-1" x 4'-8"
STAIN/STAIN
SAFETY GLAZING REQ'D
1/A2.0
P
SITTING ROOM
1
1'-1" x 4'-8"
STAIN/STAIN
SAFETY GLAZING REQ'D
1/A2.0
Q
BEDROOM 3
4
2'-10" x 2'-10"
STAIN/STAIN
1/42.0
R
BEDROOM 3
4
2'-10" x 2'-10"
STAIN/STAIN
1/A2.0
5
BEDROOM 4
4
2'-5" x 2'-II"
STAIN/STAIN
1/A2.0
T
BEDROOM 4
4
3'-4" x 2'-9"
STAIN/STAIN
3/A2.1
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
PRE -PAINTED, GALV SHEET
METAL FLASHING W END
CLOSURE. COLOR TO BE
SELECTED IN THE FIELD SLOPE
1" min.
min.
HEMMED EDGE J
E
N
END CLOSURE
HEAD FLASHING DETAIL TYP.
3"= 1'-0"
CAREFULLY LIFT (E) UJALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING UJ/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
LIFT (E) WALL UNDERLAYMENT AND
INSTALL WINDOW / NAILING FLANGE
OVER SELF ADHERING MEMBRANE
PENETRATION FLASHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND
LAP UNDER (E) WALL UNDERLAYMENT.
CAULK NEW VERTICAL SIDING JOINTS 4
SET NAIL HEADS FLUSH. PAINT MODIFIED
SIDING TO MATCH (E) SIDING
(E) SIDING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
(E) WOOD FRAME
`WALL CONSTRUCTION
11
I
ft
•
WINDOW HEAD
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE HELD DETERMINED
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
6
(E) GWB
SELF ADHERING
MEMBRANE
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING
SEALANT
SHIM 4
FILL GAP UJ/ BATT
INSULATION
WINDOW JAMB
(E) GWB
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
28 GA. GALV. FLASHING
OVER LAPPED MIN. 2"
BY (E) SIDING.
WD JAMB LINING
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT
SELF -ADHERING
MEMBRANE
(E) GWB
WINDOW SILL
WOOD SIDING/ GWB - DETAIL SET
3"=1'-0"
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF -ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF -ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
CUTBACK (E) SIDING FOR INSTALLATION
OF WINDOW ASSEMBLY 4 FLASHING.
REPLACE UJ/ NEW SIDING 4 PAINT TO
MATCH (E) SIDING
PRE -PAINTED, GALV SHEET METAL
FLASHING W END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
LIFT (E) UJALL UNDERLAYMENT AND
INSTALL WINDOW / NAILING FLANGE
OVER SELF ADHERING MEMBRANE
PENETRATION FLASHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND
LAP UNDER (E) WALL UNDERLAYMENT.
CAULK NEW VERTICAL SIDING JOINTS 4
SET NAIL HEADS FLUSH. PAINT MODIFIED
SIDING TO MATCH (E) SIDING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
GARDEN WINDOW
ASSEMBLY PER
SCHEDULE AND
SPECIFICATION
BACKER ROD 4 SEALANT
GARDEN WINDOW
ASSEMBLY PER
SCHEDULE AND
SPECIFICATION
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CUTBACK (E) SIDING FOR
(E) WOOD FRAME
,WALL CONSTRUCTION
WINDOW HEAD
WINDOW JAMB
16
INSTALLATION OF WINDOW ASSEMBLY
AND TRIM. REPLACE W/ NEW SIDING TO
MAINTAIN COURSING 4 PAINT TO MATCH
(E) SIDING
Jam(
3/4"
WINDOW SILL
(E) GWB
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING. FINISH TO
MATCH (E)
SEALANT 4 BACKER ROD
GARDEN WINDOW ASSEMBLY
PER SCHEDULE AND
SPECIFICATION
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
REVIEWED FOUR
CODEPC4R�vED CE
AJAN 3 2014
USTICAL WINDOW ASSEMBLY
ISCHEDULE
City of-ukwiia
BUILDING DIVISION
28 GA. GALV. FLASHIN
LAPPED MIN. 2" BEHIND
(E) WOOD SIDING.
(E) GWB
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING. FINISH TO
MATCH (E)
SEALANT 4 BACKER ROD
BACKER ROD 4 SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT
SELF -ADHERING MEMBRANE
2 GARDEN WINDOW - DETAIL SET
3=l-0
(E) GWB
(E) WOOD FRAME
WALL CONSTRUCTION
�1r ,
1
1
0
1
1
1
(E) GWB
SELF ADHERING
MEMBRANE
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
IUD. JAMB LINING
WINDOW HEAD
(E) SIDING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
BACKER ROD 4 SEALANT
SELF -ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETER1INED
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
J—.
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
(E) GWB
28 GA. GALV. FLASHING
OVER LAPPED MIN. 2"
BY (E) SIDING.
TOUCH UP PAINT
CONTINUOUS SEALANT, TYP.
GWB
111 111
WINDOW JAMB
ii
1
'1
1
i
WINDOW SILL
SOLID WOOD TRIM
(2) 2X STUD FRAMING
WD. JAMB LINING
BACKER ROD SEALANT
SHIM 4
FILL GAP UJ/ BATT
INSULATION
BACKER ROD 4
SEALANT
WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT
SELF -ADHERING
MEMBRANE
WOOD SIDING/ GWB - DETAIL SET
3" = 1' - 0"
(E) GWB
RECEIVED
CITY OF TUKWI
JAN 0 9 2014
A
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 •SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 824-2973
AUGUST 19, 2013
0810.03.2531
0
a_
J
Q
z
0
>-
z
W
z
z
0
U
z
AIP NUMBER
MPROVEMENTS
}
Ct
w
w
O
z
U
J
0
3-53-0058-047
z
0
0
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
PERMIT CENTE
R
TYPICAL WINDOW SCHEDULE NOTES
EXISTING FRAMING
NEW SHEATHING
INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP NEW WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
INSTALL NEW SIDING, PAINT MODIFIED
SIDING TO MATCH (E) SIDING.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
SELF -ADHERING MEMBRANE TO
WRAP ENTIRE CORNER POST
TRIM- MATCH (E) TRIM. PRIME -
ALL SIDES AND PAINT TO
MATCH (E) TRIM. COLOR TO BE
FIELD DETERMINED
2x6 FRAMING
BACKER ROD 4 SEALANT
SHIM 4 FILL GAP W/ BATT
INSULATION
ACOUSTICAL WINDOW ASSEMBLY -
PER SCHEDULE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
i1
II
WINDOW HEAD
WINDOW JAMB
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET
(E) ROOF
WINDOW SILL
SELF ADHERING
MEMBRANE
NEW GWB PAINT TO
MATCH (E) CONDITION
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
IUD. JAMB LINING
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
I I
SEALANT AND
BACKER ROD, TYP.
UJD JAMB LINING
BACKER ROD 4
SEALANT
WOOD LINING
SOLID WOOD TRIM
— CONTINUOUS
SEALANT, TYP.
NEW (2) 2X SILL PLATE
SELF -ADHERING
MEMBRANE
(i) WOOD SIDING/ GWB - DETAIL SET
3" = 1' - 0"
(E) GWB
EXIST. SIDING
(E) BAY CONSTRUCTION
t
WINDOW NAIL FIN, TYPICAL
TRIM- MATCH (E) TRIM.
PRIME ALL SIDES AND
PAINT TO MATCH (E)
TRIM. COLOR TO BE
FIELD DETERMINED
BACKER ROD 4 SEALANT
SELF -ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CUT (E) WOOD PANELING AS
REQ'D TO INSTALL WINDOW
ASSEMBLY. REPLACE AND
MATCH (E) PANELING WHERE
DAMAGED DURING CONSTR,
TYPICAL.
BACKER ROD 4 SEALANT,
TYPICAL
SOLID WOOD TRIM
(E) GWB W/ INTERIOR FINISH
SILL AT BAY WINDOW
CAREFULLY REMOVE (E) SIDING FOR
INSTALLATION OF WINDOW ASSEMBLY
AND TRIM. REPLACE W/ NEW SIDING AS
REQ'D TO MAINTAIN PANEL PATTERN 4
PAINT TO MATCH (E) SIDING, TYPICAL
ACOUSTICAL WINDOW
ASSEMBLY
PER SCHEDULE
SELF -ADHERING MEMBRANE
BACKER ROD 4 SEALANT
WINDOW NAIL FIN
TRIM- MATCH (E) TRIM.
PRIME ALL SIDES AND PAINT
TO MATCH (E) TRIM. COLOR
TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
Il
11
WINDOW HEAD
WINDOW JAMB
i1
ek
ff
4t
PRE -PAINTED, GALV SHEET
METAL FLASHING W END
CLOSURE. COLOR TO BE
SELECTED IN THE FIELD SLOPE
1" min.
I/�.�• min.
HEMMED EDGE Jf I
E
N
L END CLOSURE
HEAD FLASHING DETAIL TYP.
3"= 1'-0"
CUT (E) WOOD PANELING TO
INSTALL WINDOW ASSEMBLY.
REPLACE AND MATCH (E)
PANELING WHERE DAMAGED
DURING CONSTRUCTION,
TYPICAL
BACKER ROD 4 SEALANT,
TYPICAL
(2) LAYERS OF SELF -ADHERING
MEMBRANE, TYPICAL
BACKER ROD 4 SEALANT, TYPICAL
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
SOLID WOOD TRIM
777.777.777 .:/y F.:ryi
WINDOW SILL
BAY WINDOW - DETAIL SET
CONTINUOUS
SEALANT, TYP.
CUT (E) WOOD PANELING
TO INSTALL
WINDOW ASSEMBLY.
REPLACE AND MATCH (E)
PANELING WHERE
DAMAGED DURING CONSTR.,
TYPICAL
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
(E) SIDING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
BACKER ROD 4 SEALANT
SELF -ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
(E) WOOD FRAME
WALL CONSTRUCTION
frf i
1 1
i-1
WINDOW HEAD
WINDOW JAMB
f
€3/4"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
(E) GWB
SELF ADHERING
MEMBRANE
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
(E) GUJB
28 GA. GALV. FLASHING
OVER LAPPED MIN. 2"
BY (E) SIDING.
TOUCH UP PAINT
CONTINUOUS SEALANT, TYP.
GWB
SOLID WOOD TRIM
(2) 2X STUD FRAMING
BACKER ROD SEALANT
SHIM 4
FILL GAP UJ/ BATT
INSULATION
BACKER ROD 4
SEALANT
WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT
SELF -ADHERING
MEMBRANE
NN
WINDOW SILL
3 WOOD SIDING/ GWB - DETAIL SET
3"=1'-0"
(E) GWB
VED
CITY REOCEIF TUKVVILA
JAN 0 9 2014
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (20B) 624-2973
AUGUST 19, 2013
0810.03.2531
ce
0
0
J a z
O
O W t�
Z
LLI C/)
z Q
w O
z J
z U I —
a
U <C
J
W
0
U)
w
MPROVEMENTS
AIP NUMBER
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.1
3"=1'-0"
PERMIT CENTER
0810.03.2531
DOOR TYPES
,4
FLUSH SCW
HALF-LITE UJ/
2 PANELS
W/ SAFETY GLAZING
SECONDARY SLIDING
GLASS DOOR
W/ SAFETY GLAZING
G
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GRILLE
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
LIVING ROOM
A
3'-0" x 6'-8"
STAIN/ SLAIN
HW-I / 626
DK-4 PLYMOUTH
LOCK-1
I/A2.2
2
DINING ROOM
A
2'-8" x 6'-8"
STAIN/ STAIN
14W-I / 626
DK-4 PLYMOUTH
LOCK-1
I/A2.2
3
STUDY
A
2'-6" x 6'-1"
STAIN/ STAIN
HW-I / 626
DK-4 PLYMOUTH
LOCK-1
I/A2.2
4
BEDROOM I
B
5'-II" x 6'-8"
2/A2.2
5
LIVING ROOM
C
3'-0" x 6'-8"
I/A2.2
6
DINING ROOM
C
2'-8" x 6'-8"
I/A2.2
1
STUDY
C
2'-6" x 6'-1"
I/A2.2
t;)
1040•0 poo(D
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
PRE -PAINTED, GALV SHEET
METAL FLASHING W END
CLOSURE. COLOR TO BE
SELECTED IN THE FIELD SLOPE
I" min.
min.
HEMMED EDGE
E
N
END CLOSURE
Cs, HEAD FLASHING DETAIL TYP.
3=1-0
(E) SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
ET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF SELF
ADHERING MEMBRANE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL HEADS
FLUSH. PAINT MODIFIED SIDING TO MATCH
(E) SIDING
(E) SIDING
(E) WOOD FRAME
WALL CONSTRUCTION
G.
28 GA. GALV. FLASHING OVER
LAPPED MIN. 2" BY (E) SIDING.
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF FOR WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
DOOR HEAD
2" MIN.
SELF -ADHERING
MEMBRANE
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM 4
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
(E) SIDING
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
SELF -ADHERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE NO
MEMBRANE IS VISIBLE BELOW FLASHING
EDGE
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND DOOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR FRAME.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
City of Tukwila
BUILDING DIVISION (E) WALL UNDERLAYMENT
TOUCH UP PAINT
DOOR JAMB
EXISTING FLOOR STRUCTURE
SILL IN BEAD OF SEALANT
DOOR SILL
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM 4
FILL GAP UJ/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING/ GWB — DETAIL SET
3"= 1'-0"
DOOR HEAD
BACKER ROD AND SEALANT
SELF-ADHEARING MEMBRANE
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF DOOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PAINT TO MATCH (E) TRIM
SELF -ADHERING MEMBRANE
(E) WOOD FRAME
UJALL CONSTRUCTION
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
WD. TRIM BEYOND
LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING
MEMBRANE PENETRATION
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
PENETRATION FLASHING. PAINT
MODIFIED SIDING TO MATCH (E)
SIDING. TYP. AT HEAD AND
JAMBS
SOLID WOOD LINING
(E) PRIMARY SLIDING POOR
ASSEMBLY.
(E) VERTICAL WD. SIDING
(E) CABINETRY
LIFT (E) UJALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTINUE OVER SLIDING GLASS
DOORFRAME
i" MIN. BETWEEN PRIMARY
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS.
SEALANT
SOLID WOOD LINING
(E) PRIMARY SLIDING
GLASS DOOR
(E) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) WD. FLOOR FRAMING
RECEIVED
(E) FLOOR/ DECK FRAMING CITY OF TUKWILA
JAN 0 9 2014
PERMIT CENTER
21 WOOD SIDING/ GWB — EX. SECONDARY SLIDING DETAIL SET
3"= 1'-0"
DOOR SILL
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
AUGUST 19, 2013
0810.03.2531
AIP NUMBER
MPROVEMENTS
}
w
w
w
0
Z
J
Q
3-53-0058-047
Z
0
H
0
Z
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.2
0810.03.2531
11gip
LIMITATION AT
WINDOW
(E) WINDOW
NTS
��„ ; %%/rill%.%i/�� ���;<,:•'
/" GWB CHASE,
FINISH TO MATCH (E) TEXTURE
4 COLOR OF WALL
IUD BASE- TO
MATCH (E)
TRIM FINISH FLOOR AND
UNDERLAYMENT TO F.O.
(E) UJALL. BUTT %" TYPE
X GYP TIGHT TO SUBFLR
DUCT PER MECH.
(E) FLOOR FRAMING
(E) GLIB
WHERE WIDTH OF SOFFIT
EXCEEDS 16", INSTALL 2X4
STUDS g 16" O.C.
DUCT
I
O
0
V
�t
1
VERT. CHASE WALL
2x4 FRAMING
DEMOLISH (E) FLOOR
DEMOLISH (E) GLUES
2x2 CONT. NAILER
5/8" GLIB- PAINT TO MATCH (E) TEXTURE t
COLOR OF CEILING
ENCLOSE DUCTS TIGHTLY, OR TERMINATE
EDGE W/ ADJ. ARCHITECTURAL FEATURES
PER PLAN. COORDINATE SOFFIT DIMENSIONS
WITH MECHANICAL
(E) LID FRAME WALL ASSEMBLY
1 AIR INTAKE DETAIL AT EXTERIOR
3"=1'-0"
(E) HEAD
WINDOW TRIM
(E) SILL
WINDOW TRIM
U
•
/, 4 I
MATCH (E) INTERIOR TRIM PROFILE
(E) INTERIOR TRIM TYP.
NTS
EXISTING ROOF
(E) ROOF FRAMING
(E) EAVE VENT. MAY VERY
AT EACH PROPERTY.
..--,-::::-::;-::;.:-•::-.;:::::--- ---":-;.------..--:51:1::?::.-::
;/ rrr.
/. r .+
J+ J'
/ r
Ji r'.
,yrl,.,.r.. .. f,
INSULATION DAM DETAIL
3 = 1 -0
CEILING
4"MIN
BEST HERE
ACCEPTABLE
HERE
NOTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING.
REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND
PAINT TO FILL ALL HOLES LEFT FROM
EXISTING CONDITION. PAINT TO MATCH
SURROUNDING CONDITIONS.
BLOWN IN CELLULOSE
INSULATION WITH A COMBINED
VALUE OF NOT LESS THAN 9...4•4
INSULATION DAM
♦
SIDE WALL
(E) WALL FRAMING
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
DETECTOR INSTALLATION DETAIL TYP.
3"=1'-0"
*Pt ,--1- oocia
RECEIVED
CITY OF TUKWILA
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (208) 824-2973
AUGUST 19, 2013
0810.03.2531
0
a_
ce
J
z
0
z
cc
w
z
KING COUNTY
AIP NUMBER
MPROVEMENTS
� Z
� OO
Z
R =
W a)
fn
Z Q
nit D
U I-
Ct
J
z
W
W
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
MISC.
DETAILS
JAN 0 9 2014
PERMIT CENTER
A2.3
0810.03.2531
LIFT (E) WALL
UNDERLAYMENT
AWAY LOOSELY
FROM (E) SHEATHING
AT JAMBS AND HEAD
BUTTERFLY
CORNERS, TYP.
LAP SILL MEMBRANE
FLASHING 2-1/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND I i" BEYOND
RO. AT EA. END OF
SILL.
(E) WALL
UNDERLAYMENT
AT SILL
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
MEMBRANE FLASHING AT SILL
(E) SHEATHING
CUT SILL
FLASHING TO
EDGE OF RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
Ii" MIN
5"
k
BUTTERFLY CORNER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
MEMBRANE FLASHING
ASHING
PREVIO
USLY
Y L
APPLIED TO WINDOW
OPENINGS.
WINDOW NAIL FLANGE.
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) UJALL
UNDERLAYMENT
AT SILL.
4 SCALE: NTS
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
4" TY
INSTALL 28 GA. GALV. FLASHING OVER MEMBRANE
FLASHING LAPPED MIN. 2" BY (E) SIDING
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
REMOVED
WINDOW MEMBRANE INSTALLATION
EDGE OF (E)
SIDING, SHOILN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOUJN
FOR CLARITY.
LAY (E) WALL
UNDERLAYMENT
BACK DOWN
OVER FLANGE
FLASHING AT
JAMBS
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOUJN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
WHERE REQUIRED, TRIM
(E) WALL
UNDERLAYMENT AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
STEPS).
(FOLLOW
HEAD FLASHING PREPARATION
SCALE: NTS
(E) WALL
UNDERLAYMENT
2� SCALE: NTS
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS
SEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
CUT JAMB FLASHING TO
EDGE OF WINDOW OPENING
AS SHOWN. EXTEND I-I/2"
BEYOND EDGE OF
OPENING AT HEAD, JAMBS,
AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
TRIMMED EDGE
OF (E) SIDING,
SHOUJN
D IAGRAMATI CALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
3" TYP.
\ fl--N.c.\
i-
j)�3
`'
'r,/fir
;
is>-<
I:
r
INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
1
5
MEMBRANE FLASHING AT JAMB
SCALE: NTS
8� HEAD FLASHING INSTALLATION
SCALE: NTS
ALLOW 1/8"
BETWEEN FL
BOT. EDGE
SIDING.
LEARANCE
SHING AND
(E)
(E) UJALL
UNDERLAYMENT
INSTALL HEAD
MEMBRANE FLASHING AT HEAD
CUT HEAD
FLASHING TO
EDGE OF WINDOW
OPENING AS
SHOILN. EXTEND
1-1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: CUT (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
v
i
/r/fi
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
L
L
0 0
J
WINDOW FLASHING INSTALLATION
SCALE: NTS
I I
rJ
//
L
J
C9
WOOD TRIM INSTALLATION
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
SCALE: NTS
INSTALL WD. TRIM.
APPLY SEALANT BEAD
TO JOINT BETWEEN
WINDOW TRIM AND
SIDING.
J CHANNEL TRIM
REQUIRED FOR VINYL
SIDING INSTALLATION.
LEAVE I/4"-3/8" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING 15 SPECIFIED IN 01 62 00 AS
"SELF ADHEARING MEMBRANE FLASHING" TYPICALLY
REIERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK
JOINTS. TRIM TYPE WILL VARY DEPENDING ON (E)
SIDING MATERIAL, FINAL TRIM FINISH SELECTED BY
HOMEOWNER
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
ED
CITYROFECTIVEUKWILA
JAN 092014
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (208) 624-2973
AUGUST 19, 2013
0810.03.2531
�NN
0
z
0
>-
LLJ
z
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
H VAC
HW
HWC
HWG
HWR
H WS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
N TS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
VD
VTR
W
WB
w/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
XX
OR XX
/ X/Y
ABBR
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL
SG-X
ABBR
XXX -
DN
} I� UPI } UP
+ f �
><*1
0-9
040-
NG
•
0
D'a
t_m
VD
RA/EA
RG
SA
SA
RA/EA
SD
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
23
26
23
26
N/A
23
26
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
REMARKS
WC-1
EXTERIOR
150
430
<.08"WG
8" 0
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
SG-1
75
<.08" WG
12" X 4"
6"
WALL
850
1, 2, 5, 6
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
5. BASIS OF DESIGN: SHOEMAKER
A. OR APPROVED EQUAL.
6. PROVIDE WITH AN OPPOSED BLADE DAMPER.
SRC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2531
2875
3
150 CFM
150 CFM
1
1. VENTILATION PROVIDED PER THE SEATTLE RESIDENTIAL CODE,
SECTION M1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
MIN VALUE
NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXISTING EXTERIOR SIDING AND WINDOW TRIM PAINT.
THERMOSTAT HOURS OF OPERATION
SET FURNACE THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER SRC M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) Z
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 75 / (1 X 1/2) = 150 CFM
RECEIVED
CITY OF TUKWILA
JAN 09 2014
PERMIT CENTER
S.M. STEMPER
ARCHITECTS
A ProTosalonal 1An12ed liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 90106
(206) 624-2777 • FAx (206) 624-2073
THE GREENBUSCH GROUP, INC
UTA90A9lN♦),)
ACOUSTICAL, AUDIO VIDEO & MECHNIICAL D NEERING
1900 VEST STREET SUITE 201 SEAM, WA 96119
(206) 375-0569 (206) 376-0641 FAX
081003.2531
z
Lu
z
z
z
co
LU
Lu
0
0
Lu
Lu
LU
z
Lu
AIP NUMBER
3-53-0058-047
TUKWILA WASHINGTON
DATE
07/19/2013
ISSUED 100% CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
EXPIRES: 9/08/2014
8"0 UP
SEE
WC-1 -,
150
PATIO
CHASE, REFER TO
ARCHITECTURAL
STUDY
(E)RG
8"0 DN
(E)SG
IN TOE SPACE
UNDER RANGE
DINING
ROOM
KITCHEN
(E) OIL
TANK
PANTRY
BATH
J
PATIO
PATIO
(E)SG
(E)SG
(E)SG 1`
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
NORTH
8"
1
POC TO BOD
6"0
SEE
MECHANICAL
SG-1
75
WH
LOWER FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'—O"
NORTH
CEILING
BEDROOM
1
CLOSET
LIVING
ROOM
(E) WOOD STOVE
(E5..'�'
DRAWING NOTES:
1. RESIDENCE IS PARTIALLY CONDITIONED BY A DUCTED
FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM
10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR
NOXIOUS SOURCE PER WAC 51-51 SECTION M1507.3.5.3.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE
WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8
HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO
SATISFY WAC 51-51, SECTION M1507.3.2. (CONTROLS FOR
WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE
OF OPERATING THE VENTILATION SYSTEM WITHOUT
ENERGIZING OTHER ENERGY —CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK—OUT
WORK HAS BEEN COMPLETED AND PRIOR TO
COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR
BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS.
FLU E
FLOOR
FURNACE
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
F
(E)SG
CLOSET
BEDROOM
2
[I.
/
OUTSIDE AIR DUCT, SIZE
AND ROUTE PER PLAN
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
r
I�
SEAT
CLOSET
SITTING
ROOM
DN
BATH
BEDROOM
3
ATTIC MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
FLAG NOTES:
CLOSET
BEDROOM
4
aJ
r /
NORTH
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS
AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED.
AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING
INSTRUCTIONS)" PER WAC 51-51 SECTION M1507.3.2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE
ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET
PER WAC 51-51 M1507.3.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME
DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME
OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER
EXISTS IN THIS LOCATION, IT MAY BE REUSED.
EXTEND SUPPLY AIR DUCT TO MECHANICAL ROOM. REBALANCE COMPLETE AIR SYSTEM TO SUPPLY
EQUAL AIR QUANTITIES TO ALL SPACES AFTER DUCT AND DIFFUSER INSTALLATION.
FLOOR
(E)SUPPLY
DUCT PER PLAN
CAULK, TYP
2X BLOCKING
c
C(
-2X BLOCKING
FOAM BACKER
ROD, TYP
WALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL RETURN INSTALLATION SHOWN, SUPPLY SIMILAR.
WALL GRILLE DETAIL
SCALE: NONE
17
CHASE, REFER TO
ARCHITECTURAL
ROUND DUCT PER
PLAN
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN
2. SEE PLANS FOR VOLUME DAMPER LOCA
3. COORD. W/ARCHITECTURAL TECHNICAL
REF. 1/A2.2 FOR DETAIL.
J
(E)SIDING
SHEET METAL
FLASHING
WALL CAP
BLOCKING, TYP
2X BLOCKING,
TYP
RECEIVED
CITY OF TUKWILA
INSTRUCTIONS.
TION S.
DOCUMENTS,
WALL CAP DETAIL
SCALE: NONE
col
JAN 0 9 2014
PERMIT CENTER
S.M. STEMPER
ARCHITECTS
A Ptrotoaalonal limited d liability Company
4000 DELR1DGE WAY SW
SUITE 200 • SEATTLE, WA 90106
(208) 824-2777 • FAX (208) 024-2973
THE GREENBUSCH GROUP, INC
•00•.
•••)))
ACOUSTIC/L. AUDIO VIDEO Et MECHANICAL ENGINEERING
1900 WEST N STREET SUITE 201 SEATTLE, WA 98119
(206) 378-0589 (208) 378-0641 FAX
0810 03.2531
Lil
ct
LU
w
LU
LLI
KING COUNTY
AIP NUMBER
3-53-0058-047
TUKWILA WASHINGTON
DATE
07/19/2013
ISSUED 100% CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
MECHANICAL
PLANS AND
DETAILS
TO FURNACE
POWER SUPPLY
MECHANICAL
—71
ELECTRICAL_
LEGEND
SYMBOL
6Th80L
DESCRIPT I01N1
DESCRIPTION
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
DAMPER CONNECTION
®
-
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
MAST, WEATHERHEAD
BRANCH CIRCUIT HOME RUN
EP
0
❑'
®D
i
pT
IIII1�
o
NON -FUSED DISCONNECT SWITCH
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITN THERMAL OVERLOADS
- ------------------------------------------------------
SMOKE DETECTOR
--- - - -
TIMER OPERATED SWITCH
THERMOSTAT
-
ELECTRICAL METER
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
Cal
—
- —
CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT
®
LINE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR
E
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT 11ME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
O PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
P4T10
r
•
•
!DINING
ROOM
K
TCNEN
PATIO
C )0L
TANK
I I
TO FURNACE
DAMPER
PANTY
5ATI-4
ti
PATLy
n
a D O0M
L VING
N
ROOM
cL0 ET
E) WOOD triTOVE
SNP
RECEIVED
CITY OF TUKWILA
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 624-2777 ° FAX (206) 824-2973
co
N
Cr)
O
O
ENGINEERS, 1NO
.aim 41to Host, UMW wl
TAC M . WA w0541
,t11101. NW PI o>ve
PAX IOW WI $15
O
a
0
Z
Z
W
Z
Z
0
U
C�
Z
AIP NUMBER
MPROVEMENTS
>-
0
W
w
ce
w
CI)
0
Z
LL
U
3-53-0058-047
Z
0
z
DATE
August 19, 2013
ISSUED
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
BCR
FLOOR
PLANS
NOTES
LOWER FLOOR PLAN
1/4" = 1'
MAIN FLOOR PLAN
1/4" = 1'
JAN 0 9 2014
E1.0
0810.03.2531