HomeMy WebLinkAboutPermit D14-0007 - ADDINGTON RESIDENCE - REMODELADDINGTON RESIDENCE 4230 S 116 ST D14-0007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htta://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 3347400050 Permit Number: D14-0007 Address: 4230 S 116 ST Issue Date: 5/19/2014 Permit Expires On: 11/15/2014 Project Name: ADDINGTON RESIDENCE Owner: Name: ADDINGTON ARLENE TERRY Address: 4230 S 116TH ST , SEATTLE, WA, 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S, SEATTLE, WA, 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST, PHOENIX, AZ, 85040 License No: GGSPEGS919RT Lender: Name: FAA (RANRIP) Address: RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM, IP Phone: (206) 296-7437 Phone: (480) 921-4079 Expiration Date: 12/31/2015 DESCRIPTION OF WORK: PROJECT INVOLVES UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINT OR STRUCTURE. INCLUDES REPLACEMENT OF WINDOWS WITH VINYL -FRAMED ACOUSTICAL WINDOWS, INSTALLATION OF SECONDARY ALUMINUM -FRAMED SLIDING GLASS STORM DOORS, INSTALLATION OF SWING -OUT ALUMINUM STORM DOORS, AND INSTALLATION OF CHIMNEY -TOP ACOUSTICAL DAMPERS AT FIREPLACES AND ATTIC INSTALLATION. Project Valuation: $27,764.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Fees Collected: $1,103.22 Type of Construction: VB Occupancy per IBC: R-3 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: 2012 International Fuel Gas Code: 2012 International Residential Code Edition: 2012 WA Cities Electrical Code: 2012 International Mechanical Code Edition: 2012 WA State Energy Code: 2012 Uniform Plumbing Code Edition: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: I hearby certify that I have read and e provisions of law and ordinances gove Date: O; 1Dtt 19 ed this permit and know the same to be true and correct. All this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. �/ �%�A41.-1- Signature: �% Date: -/ 9' /7 Print Name: /li6e,h,v/z. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL CITY OF TUKKLA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: or o ce use on 04tiolc\ CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4230 S. 116th St. Tenant Name: PROPERTY OWNER Name: R A.(At N, l v' Address: 1,090 Cif - i l �� City: i aAii,i1 State: 1_ J A_ Zip: Ot itft CONTACT PERSON - person receiving all project communication Name: Sharyn Parker Address: 7277 Perimeter Road South City: Seattle State: WA Zip: 98108 Phone: (206) 296-7437 Fax: (206) 269-7315 Email: Sharyn.Parker@kingcounty.gov GENERAL CONTRACTOR INFORMATION Company Name: not yet awarded Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: 3347400050 Suite Number: Floor: New Tenant: ❑ Yes m ..No ARCHITECT OF RECORD Company Name: SM Stemper Architects, PLLC Architect Name: Timothy Fenlason Address: 4000 Delridge Way SW, Suite 200 City: Seattle State: WA Zip: 98106 Phone: (206) 624-2777 Fax: (206) 624-2973 Email: tfenlason@jonespayne.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: FAA (RANRIP) Residential Aircraft Noise Address: Remedy Improvements Program City: State: Zip: H.\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11 docx Revised, August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATIt,..—206-431 3670 Valuation of Project (contractor's bid price): $ 27,764 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Renovation of single-family home to reduce noise infiltration. This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: replacement of windows with vinyl -framed acoustical windows, installation of secondary aluminum -framed sliding glass storm doors, installation of swing -out aluminum storm doors, installation of chimney -top acoustical dampers at fireplaces and attic insulation. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 1,231 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: 1,231 Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: O Sprinklers ❑ Automatic Fire Alarm ❑ None El Other (specify) battery SmlCO Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes J No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11 docx Revised: August 2011 bh Page 2 of 4 t JBL1`C WORKS PERMIT INF,a. 4ATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District m ...Tukwila El ...Water District #125 0 ...Water Availability Provided Sewer District m ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑...Valley View ❑ .. Renton ❑...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): O ...Civil Plans (Maximum Paper Size — 22" x 34") O ...Technical Information Report (Storm Drainage) 0 .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private ❑ O ...Water Main Extension Public ❑ Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications'Forms-Applications On Line \2011 Applications\Permit Application Revised- 8-9-11. docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR 4UTHORIZED AGENT: Signature: Print Name: Tinfothy Fe Mailing Address: 4000 Delridge Way SW, Suite 200 Date: Q cp4A 0((-( Day Telephone: (206) 624-2777 Seattle WA 98106 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11. docx Revised August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 014-0006 Address: 4928 S 113 ST Apn: 3348401741 $1,337.30 DEVELOPMENT $1,298.10 PERMIT FEE R000.322.100.00.00 $784.00 PLAN CHECK FEE R000.345.830.00.00 $509.60 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $39.20 TECHNOLOGY FEE R000.322.900.04.00 $39.20 014-0007 Address: 4230 S 116 ST Apn: 3347400050 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0008 Address: 4811 S 124 ST Apn: 0179003115 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0009 Address: 12216 47 AVE S Apn: 0179001140 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0010 Address: 5702 S PAMELA DR Apn: 7344000020 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11 :. "SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0010 Address: 5702 S PAMELA DR Apn: 7344000020 $1,077.20 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0011 Address: 4702 S 124 ST Apn: 0179001210 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0012 Address: 12212 46 AVE S Apn: 0179000910 $1,129.22 DEVELOPMENT $1,096.14 PERMIT FEE R000.322.100.00.00 $661.60 PLAN CHECK FEE R000.345.830.00.00 $430.04 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $33.08 TECHNOLOGY FEE R000.322.900.04.00 $33.08 D14-0013 Address: 11870 44 PL S Apn: 3347400790 $957.70 DEVELOPMENT $929.66 PERMIT FEE R000.322.100.00.00 $560.70 PLAN CHECK FEE R000.345.830.00.00 $364.46 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $28.04 TECHNOLOGY FEE R000.322.900.04.00 $28.04 D14-0014 Address: 4716 S 122 ST Apn: 3347401455 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 I I $32.32 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0015 Address: 4920 S 114 ST Apn: 3348401711 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0016 Address: 13049 56 AVE 5 Apn: 2172000060 $1,285.28 DEVELOPMENT $1,247.61 PERMIT FEE R000.322.100.00.00 $753.40 PLAN CHECK FEE R000.345.830.00.00 $489.71 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $37.67 TECHNOLOGY FEE R000.322.900.04.00 $37.67 D14-0017 Address: 12055 44 AVE 51 Apn: 3347400420 $657.82 DEVELOPMENT $638.60 PERMIT FEE R000.322.100.00.00 $384.30 PLAN CHECK FEE R000.345.830.00.00 $249.80 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE R000.322.900.04.00 $19.22 D14-0018 Address: 12404 50 PL S Apn: 0179002265 $1,207.26 DEVELOPMENT $1,171.88 PERMIT FEE R000.322.100.00.00 $707.50 PLAN CHECK FEE R000.345.830.00.00 $459.88 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $35.38 TECHNOLOGY FEE R000.322.900.04.00 $35.38 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 DEVELOPMENT $1,323.35 PERMIT FEE R000.322.100.00.00 $799.30 PLAN CHECK FEE R000.345.830.00.00 $519.55 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11 WV •SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 TECHNOLOGY FEE $39.97 TECHNOLOGY FEE R000.322.900.04.00 $39.97 D14-0020 Address: 12012 44 AVE S Apn: 3347401060 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0021 Address: 12020 42 AVE S Apn: 3347400290 $1,493.36 DEVELOPMENT $1,449.57 PERMIT FEE R000.322.100.00.00 $875.80 PLAN CHECK FEE R000.345.830.00.00 $569.27 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $43.79 TECHNOLOGY FEE R000.322.900.04.00 $43.79 D14-0022 Address: 4925 S 125 ST Apn: 0179002840 $1,259.28 DEVELOPMENT $1,222.37 PERMIT FEE R000.322.100.00.00 $738.10 PLAN CHECK FEE R000.345.830.00.00 $479.77 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $36.91 TECHNOLOGY FEE R000.322.900.04.00 $36.91 014-0023 Address: 1223146 AVE S Apn: 0179000840 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0024 Address: 4702 S 122 ST Apn: 3347401430 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0025 Address: 11608 40TH AVE S Apn: 7340600140 $1,545.38 DEVELOPMENT $1,500.06 PERMIT FEE R000.322.100.00.00 $906.40 PLAN CHECK FEE R000.345.830.00.00 $589.16 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $45.32 TECHNOLOGY FEE R000.322.900.04.00 $45.32 D14-0026 Address: 13007 57TH AVE S Apn: 2137000020 $791.10 DEVELOPMENT $767.96 PERMIT FEE R000.322.100.00.00 $462.70 PLAN CHECK FEE R000.345.830.00.00 $300.76 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $23.14 TECHNOLOGY FEE R000.322.900.04.00 $23.14 D14-0027 Address: 12239 46 AVE S Apn: 0179000830 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 DEVELOPMENT $1,348.59 PERMIT FEE R000.322.100.00.00 $814.60 PLAN CHECK FEE R000.345.830.00.00 $529.49 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11 eSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 TECHNOLOGY FEE $40.73 TECHNOLOGY FEE R000.322.900.04.00 $40.73 M14-0005 Address: 4928 S 113 ST Apn: 3348401741 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0006 Address: 4230 S 116 ST Apn: 3347400050 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0007 Address: 4811 S 124 ST Apn: 0179003115 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.10200.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0008 Address: 12216 47 AVE S Apn: 0179001140 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0009 Address: 5702 S PAMELA DR Apn: 7344000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0010 Address: 4702 S 124 ST Apn: 0179001210 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137,75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0011 Address: 4928 S 113 ST Apn: 3348401741 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0012 Address: 11870 44 PL S Apn: 3347400790 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11 erow SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0014 Address: 4920 S 114 ST Apn: 3348401711 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0015 Address: 13049 56 AVE S Apn: 2172000060 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0016 Address: 12055 44 AVE S 1 Apn: 3347400420 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100:00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0017 Address: 12404 50 PL S Apn: 0179002265 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0018 Address: 11836 44 AVE S Apn: 3347401015 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0019 Address: 12012 44 AVE S Apn: 3347401060 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0020 Address: 12020 42 AVE S Apn: 3347400290 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0021 Address: 4925 S 125 ST Apn: 0179002840 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11 OWN, SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0023 Address: 4702 S 122 ST Apn: 3347401430 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0024 Address: 11608 40TH AVE S Apn: 7340600140 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0025 Address: 13007 57TH AVE S Apn: 2137000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100:00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0026 Address: 12239 46 AVE S Apn: 0179000830 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $30,413.70 M14-0030 Address: 11664 44 AVE S Apn: 3347400690 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 TOTAL FEES PAID BY RECEIPT: R1222 $30,413.70 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11 - SYSTEMS Di INSPECTION NO. PERMIT NO. �(/f CITY OF TUKWILA BUILDING DIVISION G/ INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670, Permit Inspection Request Line (206) 431-2451 Proje t: < Type of nspe tion• \ Address: r l i'✓) . 1" Date ailed: ' t.� Z. , / , - -i S0� , IL't,i)" Special Instructions: , Date Wanted: 3 t/ 2-- j p.m. Requester: Phonelto: ( {- 5 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Insp Date: tor: REINSPECTION PEE REi#U]RED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. kRMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0007 DATE: 01/10/2014 PROJECT NAME: Addington Residence SITE ADDRESS: 4230 S 116 St X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: c, M.IC.I1-1 Building Division II Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) A2.; DUE DATE: 02/11/14 zr REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 G & G SPECIALTY CONTRCTOR ° INC Page 1 of 2 C: Washington State Department of Labor & Industries G & G SPECIALTY CONTRCTORS INC Owner or tradesperson GOODBALLET, JAMES SCOTT Principals GOODBALLET, JAMES SCOTT, PRESIDENT GOODBALLET, TERESA LYNN, SECRETARY GOODBALLET, CHARLES ELMER, CHIEF EXECUTIVE OFFICER WAVY, CHRISTINE, CHIEF OPERATING OFFICER Doing business as G & G SPECIALTY CONTRCTORS INC WA UBI No. 602 975 812 Parent company G & G SPECIALTY CONTRCTORS INC 1221 N. Monde! DR GILBERT, AZ85233 480-921-4079 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GGSPEGS919RT Effective — expiration 12/31 /2009-12/31 /2015 Bond HARTFORD FIRE INS CO Bond account no. 59BSBEA9058 $12,000.00 Received by L&I Effective date 01/03/2011 12/18/2010 Bond history Insurance National Union Fire Ins of PA $1,000,000.00 Policy no. xnd0055800 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014 KI C:SIJ TY I T RNATIONAL AIRP RT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00860C13 BID PACKAGE M•-43 3-53-0058-047 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWING AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO: APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X 11. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WIRING. X SEPARATE i-api:\ri T QU'iR FOR: f� : tR Mechanical Electrical Plumbing Gas Piping C 'y of Tu'.< is E1t111.r`i ,;•;1C,1 FILAL2La Permit No. Plan review approval is subject to errors and o mishsions.. Approval of construction documents does not orlm the violation of any adopted code or ordinance. Receipt of approved Field Cody and conditions is acknowledged: BY Date:, 1 l�- / __ City Of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 9,..g 12.. international Residential Code, international Fire Code, International Mechanical Code yo12 iff4W0 3341400050 ZONING: 6F1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V 6 NON SPRINKLERED REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 • rn- City of u iia BUILDING !SION LEGAL DESCRIPTION: LOTS 10 AND 11, BLOCK I, HILLMANS MEADOW GARDENS DIVISION NO. I, VOLUME 12, PAGE 64, LESS R/W, SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. DRAWING INDEX T0.0 A1.0 A2.0 A2.1 ,422 A23 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS A2.4 WINDOW FLASHING DETAILS MI.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: SharynParkerekingcounty.gov ARCHITECT: SM. &temper Architects PI..L.C. 4000 Deiridgs Way SW, Sulte 200 Seattle, WA 98106 Fh: 206. &24. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody LeungE-mail: Jerryesmstemper.com melodyesmstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Ait Allaoua E-mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Fh: 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E-mail: DylanTe reenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E-mail: tim ogdenepbsenvcom DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. *200 Boston, MA 02114 Contact: Tim Fenlaeon, Cynthia Maeda E-mail: trenlasonejonespaynecom CMa edae jonespa yne.com STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E-mail: ronmspsm-engineers.com REVISIONS No changes shall bo made to the scope of work without prior approval of Tukwila Building Division. NOTE: Rovisans will require a nsw plan submittal and may include additional plan review fees. VICINITY MAP (NTS) S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624-2777 • FAX (206) 824-2973 0810.03.2534 AUGUST 19, 2013 ce 0 a ce 0 J Z Z W H Z Z O U C.9 z MPROVEMENTS >- 0 W 2 w w 0 z u_ U Q J Q w Y RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER AIP NUMBER 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.O 0810.03.2534 O O O BEDROOM — (E) GAS FIREPLACE BATH -(E) CABINET SC GAS [.._ ........ SPECIAL NOTES: 1. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT WERE PRESENT PRIOR TO CONSTRUCTION. 2. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 II 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 3. THIS RESIDENCE HAS EXISTING WIDE INTERIOR TRIM. NEW TRIM TO MATCH EXISTING INTERIOR TRIM PROFILE. REFERENCE 5/A23 FOR PHOTOS. WINDOWS 'E. F. 4 G' MATCH EXISTING INTERIOR WOOD LINER REFERENCE 5/A2.2 FOR PHOTOS. 4. REFERENCE 4/A23 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. SALVAGE EXISTING WINDOWS TO HOMEOWNER 6. SURPLUS (E) FRONT DOOR, STORM DOOR AND HARDWARE TO HOMEOWNER 1. KNOB AND TUBE WIRING PRESENT. BEDROOM 2 (E) 20" x 30" ATTIC ACCESS PANEL SITTING ROOM (E) GAS FIREPLACE d LIVING ROOM KITCHEN DINING ROOM MAIN FLOOR PLAN 1/4" = 1' GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 FM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 FM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. II. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRICT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 60 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 1a INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. IS. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 All. 4 AFTER 5:00 P111. 21'-8" \ �\ I\ \ it it \ / y / / \ / /4 / 4 LI \ (E) 20" x 30" I - A1`TIC ACCESS I I \ PANEL I ...\ I€ II E=2- C—� =a -% -../ -/ / / / TYP. L • / / 1 / / E_ \ / / / / / t / / / / I. - r I /- I - i I / / / 7 \ - - - !/. . 1 - • � - - - - - - - \ / / \ / / / / / / / IL — PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE. DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND OSTORM DOOR REF: DOOR SCHEDULE. ODEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW INTERIOR DOOR, FRAME, CASING, TRIM AND 3 THRESHOLD. REF: DOOR SCHEDULE. OINSTALL VENT BAFFLE AT (E) ROOF VENT IN ATTIC PER MANUFACTURE'S INSTRUCTIONS. REF: 3/A23 FOR DETAIL. ODEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: I/A23 FOR DETAIL. REF: MECHANICAL DOCUMENTS. OCOORDINATE INSTALLATION OF NEW THERMOSTAT WITH MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO I-I0MEOWNER DRIVEWAY. / ATTIC PLAN 1 Co REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION 1/4" = 1' LEGEND • A. SOUTH ELEVATION B. WEST ELEVATION C. NORTH ELEVATION D. EAST ELEVATION blor El j._...._..m ACOUSTICAL WINDOW X col A El ❑s REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW NEW THERMOSTAT TIMER SWITCH FOR BLENDED AIR UNIT n-r m rr€rr m 111UJ11ULW E-9 K=� E-� 11e GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A •MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT .:- ATTIC ACCESS PANEL N.?-CEILING DEMOLITION FOR ATTIC PANEL ....1 AND WHOLE HOUSE VENT INSTALLATION. ...' REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 'GAS ATTIC INSULATION ATTIC INSULATION DAM INSTALL BATTERY OPERATED SMOKE DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER NEW SOFFIT CEILING PATCH WORK S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2534 IL 0 z 0 z LU z KING COUNTY MPROVEMENTS z O 0 z RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER AIP NUMBER 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES AI.O 0810.03.2534 WINDOW TYPES 1. FIXED 2. FIXED UJ/ GRIDS // 3. 4. DOUBLE - HUNG HORI ZONTAL XX SLIDER 5. HORIZONTAL XX SLIDER UJ/ GRIDS WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH I NT./ EXT. REMARKS DETAIL SET A LIVING ROOM 2 2'-T" x 4'-1" STAIN/STAIN SAFETY GLAZING RECTO 2/A2.0 B LIVING ROOM I 5'-3" x 4'-1" STAIN/STAIN SAFETY GLAZING REQ'D 2/A2.0 C LIVING ROOM 2 2'-7" x 4'-1" STAIN/STAIN SAFETY GLAZING REQ'D 2/A2.0 D SITTING ROOM 4 3'-9" x I'-9" STAIN/STAIN I/A2.0 E BEDROOM 1 3 2'-6" x 4'-0" STAIN/STAIN 1/42.0 F BEDROOM 1 3 2'-6" x 4'-0" STAIN/STAIN I/A2.0 G BEDROOM 1 3 2'-6" x 4'-0" STAIN/STAIN 1/A2.0 H BEDROOM 2 4 5'-10" x 2'-0" STAIN/STAIN 1/A2.0 I KITCHEN 4 5'-10" x 2'-10" STAIN/STAIN (E) TILE SILL AND FRP PANELING 1/A2.1 J DINING ROOM 4 5'-11" x 4'-11" STAIN/STAIN (E) FRP PANELING 2/A2.1 K LIVING ROOM 5 5'-II" x 4'-11" STAIN/STAIN 1/A2.0 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. PRE -PAINTED, GALV SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE I" min. min. HEMMED EDGE Jf E N LEND CLOSURE HEAD FLASHING DETAIL TYP. 3"= 1'-0" (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL PROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OvER TOP OF SELF ADHERING FLASHING. UNDETERMINED VINYL SIDING SUBSTRATE REMOVE (E) VINYL SIDING FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SET PRE -PAINTED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEEt. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE HELD DETERMINED ACOUSTICAL WINDOW ASSEMBL PER SCHEDULE CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING UNDETERMINED VINYL SIDING SUBSTRATE VINYL J CHANNEL TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE SEALANT 4 BACKER ROD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) (E) WOOD FRAME WALL CONSTRUCTION WINDOW HEAD WINDOW JAMB WINDOW SILL (E) GWB SELF ADHERING MEMBRANE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP UJ/ BATT INSULATION SEALANT 4 BACKER ROD REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION (E) GWB TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LINING. FINISH TO MATCH (E) BACKER ROD SEALANT SHIM 4 FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD WOOD SILL SOLID WOOD TRIM SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4". CONTINUOUS SEALANT, TYP. VINYL SIDING/ GWB - DETAIL SET 3"=1'-0" TOUCH UP PAINT (E) GUIB EXIST. SIDING (E) BAY CONSTRUCTION ;tf WINDOW NAIL FIN, TYPICAL TRIM- MATCH (E) TRIM. PRIME ALL SIPES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE 1 1 f l � TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTR, TYPICAL. BACKER ROD 4 SEALANT, TYPICAL SOLID WOOD TRIM (E) GUI5 UJ/ INTERIOR FINISH SILL AT BAY WINDOW CAREFULLY REMOVE (E) SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN PANEL PATTERS 4 PAINT TO MATCH (E) SIDING, TYPICAL ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE SELF -ADHERING MEMBRANE BACKER ROD 4 SEALANT WINDOW NAIL FIN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT 2 WINDOW HEAD CUT (E) WOOD PANELING TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTRUCTION, TYPICAL BACKER ROD 4 SEALANT, TYPICAL (2) LAYERS OF SELF -ADHERING MEMBRANE, TYPICAL BACKER ROD 4 SEALANT, TYPICAL ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE WINDOW JAMB b 1+0007 SOLID WOOD TRIM /.:Z2Z2222::;-:z. 7.. r/ : zZ �,r,�, :z* :2zz1:r.�- WINDOW SILL VINYL SIDING/ GWB - BAY WINDOW DETAIL SET CONTINUOUS SEALANT, TYP. CUT (E) WOOD PANELING TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTR, TYPICAL RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 . SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2534 0 0_ J z 0 z LU z H z 0 U 0 z AIP NUMBER MPROVEMENTS >- 0 ww w w (1) 0 z 0 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 3"=1'-0" 0810.03.2534 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. PRE -PAINTED, GALv SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE I" min. 14." min. HEMMED EDGE _J END CLOSURE HEAD FLASHING DETAIL TYP. 3"=1'-0" (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. UNDETERMINED VINYL SIDING SUBSTRATE REMOVE (E) VINYL SIDING FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCE550RIE5 TO MATCH (E). VINYL J CHANNEL TRIM SET PRE -PAINTED, GALv SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A"ON THIS SHEET. TRIM- MATCH (E) TRIM_ PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) vINYL SIDING UNDETERMINED vINYL SIDING SUBSTRATE VINYL J CHANNEL TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT (E) WOOD FRAME WALL CONSTRUCTION SELF ADHERING MEMBRANE FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD WINDOW HEAD SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE SEALANT 4 BACKER ROD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) 11 (E) GWB (E) FRP PANEL WD. JAMB LINING WINDOW JAMB SHIM 4 FILL GAP W/ BATT INSULATION ✓,r SEALANT 4 BACKER ROD INSTALL NEW CERAMIC TILE SILL. CONTRACTOR COORD. WITH HOMEOWNER FOR TILE COLOR SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4". (E) FRP PANEL WINDOW SILL (E) GWB (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADI-IERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. UNDETERMINED VINYL SIDING SUBSTRATE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SET PRE -PAINTED, GALv SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE CAREFULLY REMOVE (E) vINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) vINYL SIDING UNDETERMINED VINYL SIDING SUBSTRATE VINYL J CHANNEL TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE SEALANT 4 BACKER ROD (E) WOOD FRAME WALL CONSTRUCTION • L. (E) GWB (E) FRP PANEL SELF ADHERING MEMBRANE SHIM 4 FILL GAP W/ BATT INSULATION WINDOW HEAD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) bl'r0007 ry. l�l SEALANT 4 BACKER ROD REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION (E) GWB (E)FRP PANEL WINDOW JAMB rr i WINDOW SILL SHIM 4 FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4". (E) FRP PANEL (E)GWB RECEIVED CITY OF TUKWILA JAN 092014 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 MPROVEMENTS 0810.03.2534 AIP NUMBER 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS 1 VINYL SIDING/ FRP PANEL/ TILE - DETAIL SET 3"=1'-0" WOOD SIDING/ GWB - DETAIL SET 3"=1'-0" PERMIT CENTER A2.1 0810.03.2534 DOOR TYPES A FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING UJ/ OBSERVATION PORT 8 EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING ROOM A 2'-S" x 6'-S" STAIN/ STAIN HW-I / XOX XXX LOCK -I I/42.2 2 KITCHEN A 2'-S" x 6'-S" 2/42.2 3 LIVING ROOM B 2'-S" x 6'-S" 1/42.2 NOTES: DOOR '3' FULL LITE KEYED/ LEVER STORM. SURPLUS EXISTING FRONT DOOR, STORM DOOR AND HARDWARE TO HOMEOWNER TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET. PRE -PAINTED, GALV SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE HEMMED EDGE — - -J L END CLOSURE HEAD FLASHING DETAIL TYP. 3"=1'-0" (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOvE (E) vINYL SIDING AS REQ'D FOR INSTALLATION OF DOOR 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SEALANT 4 BACKER ROD SET PRE -PAINTED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEET. CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OvER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMovE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF DOOR 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SEALANT 4 BACKER ROD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. (E) WOOD FRAME WALL CONSTRUCTION DOOR HEAD 2" MIN. DOOR JAMB DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP 1 EXISTING FLOOR STRUCTURE SILL IN BEAD OF SEALANT UNDETERMINED vINYL SIDING SUBSTRATE SELF ADHERING MEMBRANE TOUCH UP FAINT, AS REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEAXNER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION SELF ADHERING MEMBRANE DOOR SILL TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION WOOD FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE VINYL SIDING/ GWB - DETAIL SET 3"=1'-0" SHIM 4 FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING DOOR HEAD SHIM 4 FILL GAP UJ/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING TOUCH UP FAINT CONTINUOUS SEALANT, TYP. SOLID UJOOD TRIM INTERIOR DOOR PER SCHEDULE EXISTING FRAMING TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM DOOR JAMB biL1-OOO7 JAMB BEYOND WOop DOOR PER SCHEDULE DOOR SHOE DOOR PER SCHEDULE DOOR SILL RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER GWB - INTERIOR DOOR DETAIL SET 3"= 1'-0" S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2534 0 a. ce J z 0 z w z z 0 0 0 Z AIP NUMBER MPROVEMENTS 3-53-0058-047 Z 0 H C9 z DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.2 0810.03.2534 y rJ;. -r , r rr •` /, EXISTING SOFFIT AND FRAME SEALANT PAINT VENTILATION HOOD, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION HOOD. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN BEAD OF SEALANT AT EXTERIOR TRIM REPLACEMENT SIDING UNDETERMINED VINYL SIDING SUBSTRATE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM 2X BLOCKING 2X2 CONTINUOUS BLOCKING, 4 SIDES AIR INTAKE DETAIL AT EXTERIOR 3" = 1' - 0" (REVERSED) 2X BLOCKING EXISTING VENT COVER EXISTING ROOF VENT EXISTING ROOF STRUCTURE NEW 2"X SPACER CROSS SECTION EXISTING ROOF STRUCTURE NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE „-'1 . ` -- ,7 ', r`_ 'r's\ r:'rr! „r ter'"-' ter'''! r i r'''C !,. fr'' ; -->- ,r`,r r _/ :r ••r f''r 'l' LATERAL SECTION ROOF VENT BAFFLE DETAIL 1 1/2" = 1' - 0" CEILING BEST HERE ACCEPTABLE HERE 4"MIN NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. C._ 61 6" MIN. TYPICAL TOP t BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. SIDE WALL DETECTOR INSTALLATION DETAIL TYP. EXISTING ROOF (E) ROOF FRAMING (E) EAYE VENT. MAY VERY AT EACH PROPERTY. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION •✓ • , J,r Y' • `,✓���' • ,fir `,• ✓;;;;; 'r lrrr`•r r .ram,'✓✓ rrjr- r r ram• .r''✓'' r r rr r • r INSULATION DAM DETAIL BLOWN IN CELLULOSE INSULATION WITH A COMBINED VALUE OF NOT LESS THAN .fig. INSULATION DAM (E) WALL FRAMING (E) HEAD WINDOW TRIM (E) SILL WINDOW TRIM 3" = 1' -0" MATCH (E) INTERIOR TRIM PROFILE (E) INTERIOR TRIM TYP. `� ;r::%/iiiiiiibir. s's �fs's%1,�,,,"/.%/„J," ; ; •ll� ,. y,,, RECEIVED CITY OF TUKW JAN 0 9 2014 ILA S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824-2777 • FAX (208) 824-2973 AUGUST 19, 2013 0810.03.2534 I-- 0 IL c J z 0 z w z KING COUNTY AIP NUMBER MPROVEMENTS 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.3 3"=1'-0" NTS PERMIT CENTER 0810.03.2534 LIFT (E) WALL UNDERLAYMENT AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY COMERS, TYP. LAP SILL MEMBRANE FLASHING 2-1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA. END OF SILL. (E) WALL UNDERLAYMENT At SILL NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. 12" MEMBRANE FLASHING AT SILL (E) SHEATHING CUT SILL FLASHING TO EDGE OF RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 1i" MIN J( 511 BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) WALL UNDERLAYMENT AT SILL. REMOVED NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. 4" TY INSTALL 2S GA. GALV. FLASHING OVER MEMBRANE FLASHING LAPPED MIN. 2" BY (E) SIDING ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS EDGE OF (E) SIDING, SHOWN D I AGRAMAT I CA L LY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE ,AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING WHERE REQUIRED, TRIM (E) WALL UNDERLA NT At HEAD TO -REPARE FOR INST LATION OF HEAD FLA RING AND WINDOW TRI 0 0 I►' STEPS). L J (E) WALL UNDERLAYMENT NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. CUT JAMB FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS c5) INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. 3" TYP. - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. ALLOW 1/8" BETWEEN FL BOT. EDGE SIDING. LEARANCE SHING AND (E) (E) WALL UNDERLAYMENT INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF UJALL) SCALE: NTS 6 NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. WINDOW FLASHING INSTALLATION SCALE: NTS r -� I III 1 I L J SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. J CHANNEL TRIM REQUIRED FOR VINYL SIDING INSTALLATION. LEAVE I/4"-3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO A5 "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. TRIM TYPE WILL VARY DEPENDING ON (E) SIDING MATERIAL, FINAL TRIM FINISH SELECTED BY HOMEOWNER REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 092014 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2534 1--- 0 J z 0 Z W Z Z 0 U C� Z AIP NUMBER MPROVEMENTS >- 0 w 2 W w 0 z u_ W 0 LL! 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS HEAD FLASHING PREPARATION SCALE: NTS HEAD FLASHING INSTALLATION SCALE: NTS C9. WOOD TRIM INSTALLATION SCALE: NTS PERMIT CENTER ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTU H CD CFM CIRC COND CON T COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW H WC HWG HWR H WS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB w/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL 4 XX ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW OR XX EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y/ --S /A- X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG-X XXX ABBR -NW ± O-9 Ot NG ICI • 0 D'a DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP VD RA/EA RG SA SA RA/EA SD DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 23 26 23 26 N/A 23 26 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE REMARKS WC-1 EXTERIOR 90 337 <.08"WG 7"0 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2534 1235 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. THERMOSTAT/SWITCH HOURS OF OPERATION SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS. b 0007 MECHANICAL VENTILATION CALCULATION PER WAC 51-51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) 45 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER S.M. STEMPER ARCHITECTS A Prot wdonel Waited liability Company 4000 I)ELRIDGE WAY SW SUITE 200 SEATTLE, WA 90100 (200) 024-2777 • FAX (206) 624-2973 THE GREENBUSCH GROUP,INC 9411004140090 ACOUSRCAL, AUDIO / VIDEO & MECIW CN. ENDNIEERINO 1903 WEST NICKEA90N 91REEf SU0E 201 SEAAE, Mq 95119 (206) 376-0569 (206) 37e-0541 FAX 081003.2534 0 ce 0 Lu KING COUNTY AIP NUMBER 3-53-0058-047 T U KW I LA WAS H I N G TO N DATE 07/19/2013 ISSUED 100%, CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & WG INDEX EXPIRES: 9/08/2014 BEDROOM 1 - (E) GAS FIREPLACE NO TREATMENT (E)SG I r1 1- LJ rn 0 0 BA I.. BEDROOM 2 7" (E) 20„ xr 30•, ATTIC ACCESS PANEL SITTING ROOM (E)SG (E) GAS FIREPLACE NO TREATMENT asa MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" CEILING REFRIGERANT LINES ELEC. PANEL FLOOR MOD, INTERLOCK TO FURNACE OUTSIDE AIR DUCT, SIZE AND ROUTE PER PLAN 0 (E)LIGHT ELEC. PANEL DOOR KEEP DUCT 4" MIN. FROM ELECTRICAL PANEL KITCHEN DINING ROOM (E)SG x LIVING ROOM (E)SG 4r1IN NORTH FILTER c FURNACE (E)SUPPLY S (E)RETURN OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE WATER HEATER POC VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING FLUE WC-1 90 SEE • • • / / • • / �F T • / _--L... ...._I t- / Er- .--.- / / I-- l I / II V I L_ _..ri..._ (E)SIDING SHEET METAL FLASHING 2X2 BLOCKING WALL CAP 2X2 BLOCKING �r rr 1".• 11 II// jz. I/K ATTIC MECHANICAL PLAN SCALE: 1/4" = 1'-0" vA 2X BLOCKING, TYP SLEEVE AND ESCUTCHEON HARD DUCT PER PLAN CAULK, TYP FOAM BACKER ROD, TYP NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. WALL CAP DETAIL SCALE: NONE C / • 11 L • (E) 20" x 30" \ ATTIC ACCESS \ PANEL \ J / / / / \ / \ _ / \ / Y / / / / / / / • / • \ • • • / 1 \ ♦ / • • / I \ \ / I \ \ / I I- • /\ 1 / \ _(/ // \\ \ \� / \ / \ / \ / \ /\ �/ \A NORTH DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51 SECTION M1507.3.5.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY WAC 51-51, SECTION M1507.3.2. (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51 SECTION M1507.3.2. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51-51 M1507.3.5.1. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. RECEIVED CITY OF TUKWILA JAN092014 PERMIT CENTER EXPIRES' S.M. STEMPER ARCHITECTS A Fxofeeadonni Limited Liabllily Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 981.06 (200) 024-2777 FAX (200) 024-2973 THE GREENBUSCH GROUP, INC MOW W1111111, )).) ACOUSRCAL. AU010 VIDEO & MECHANICAL ENGINEERING 1900 WEST MCI.N STREET SURE 201 SEATTLE. WA 98119 (200) 370-0559 (200) 370-0941 FAX 0810.03.2534 co z w w O � ce � a Z Z � 0 O L.L. C.'? ct z �cco o Lu z z gLL v O Ct z z w 0 w AIP NUMBER 3-53-0058-047 DATE 07/19/2013 ISSUED 100% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA MECHANICAL PLANS AND DETAILS 1tEQUhRED ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH —IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES O PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. ELECTRICAL LEGEND SYMBOL SYMBOL DESCRIPTION DESCRIPTION G LIGHTING OR POWER PANEL - ® MY 4 D ❑S' ® I I I I o 1 NON -FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS SMOKE DETECTOR TIMER OPERATED SWITCH 'THERMOSTAT 11 — - — CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT ® UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR E f • BED RO (E) GAB F REPL4 E NO Tom; 4T ENT BATH L. r TO RI POWER (E) 20» 30" ATTIC ACCESS - PANEL, SITTING ROOT i (E) FIREPLACE, NO TREATMENT TO RMACE DAMPER KITC -4 N rINNc f c Q"1 ROOM 0101 RECEIVED CITY OF TUKWILA JAN 0 9 2014 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 96106 (206) 624-2777 • FAX (206) 624-2973 0810.03.2534 ■NOINt�lle, INC WM WOUM 4W0 *TM. 811111101 TAOOMA WA M10M.. MMM• ODM m ONO PAX — X SIM ce 0 a ce 0 ce Z Z W F�- Z O U 0 Z AIP NUMBER MPROVEMENTS 3-53-0058-047 DATE August 19, 2013 ISSUED 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN BCR FLOOR PLANS NOTES MAIN FLOOR PLAN 1/4"=1' PERMIT CENTER SEPARATE PERMIT AND APPROVAL Dmli HAM