Loading...
HomeMy WebLinkAboutPermit D14-0008 - CHEN RESIDENCE - UPGRADESCHEN RESIDENCE 4811 S 124 ST D14-0008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Aov DEVELOPMENT PERMIT Parcel No: 0179003115 Permit Number: D14-0008 Address: 4811 S 124 ST Issue Date: 5/19/2014 Permit Expires On: 11/15/2014 Project Name: CHEN RESIDENCE Owner: Name: CHEN WEI TING Address: 4811 S 124TH ST, TUKWILA, WA, 98178 Contact Person: Name: SHARYN PARKER Phone: (206) 296-7437 Address: 7277 PERIMETER RD S, SEATTLE, WA, 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST, PHOENIX, AZ, 85040 License No: GGSPEGS919RT Lender: Name: FAA (RANRIP) Address: RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM, Phone: (480) 921-4079 Expiration Date: 12/31/2015 DESCRIPTION OF WORK: PROJECT INVOLVES UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINT OR STRUCTURE. INCLUDES REPLACEMENT OF WINDOWS WITH VINYL -FRAMED ACOUSTICAL WINDOWS, INSTALLATION OF SECONDARY ALUMINUM -FRAMED SLIDING GLASS STORM DOORS, INSTALLATION OF SWING -OUT ALUMINUM STORM DOORS, AND INSTALLATION OF CHIMNEY -TOP ACOUSTICAL DAMPERS AT FIREPLACES AND ATTIC INSTALLATION. Project Valuation: $27,492.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Fees Collected: $1,103.22 Type of Construction: VB Occupancy per IBC: R-3 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: 2012 International Fuel Gas Code: 2012 International Residential Code Edition: 2012 WA Cities Electrical Code: 2012 International Mechanical Code Edition: 2012 WA State Energy Code: 2012 Uniform Plumbing Code Edition: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: ♦ ►i►R Date: ig (`'\ I hearby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances gov- this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name/ (/�,� I/4f�% IZ4MZ Date: 5— 9—/Y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL 1 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. No. )ate Application Accepted: Date Application Expires: or o bot 0 ce use on. CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4811 S. 124th St. Tenant Name: PROPER OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Sharyn Parker Address: 7277 Perimeter Road South City: Seattle State: WA zip: 98108 Phone: (206) 296-7437 Fax: (206) 269-7315 Email: Sharyn.Parker@kingcounty.gov GENERAL CONTRACTOR INFORMATION Company Name: not yet awarded Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: 0179003115 Suite Number: Floor: New Tenant: 0 Yes ..No ARCHITECT OF RECORD Company Name: SM Stemper Architects, PLLC Architect Name: Timothy Fenlason Address: 4000 Delridge Way SW, Suite 200 City: Seattle State: WA zip: 98106 Phone: (206) 624-2777 Fax: (206) 624-2973 Email: tenlason@jonespayne.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: FAA (RANRIP) Residential Aircraft Noise Address: Remedy Improvements Program City: State: Zip: H: Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11. docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATIL„ . — 206-401-3670 Valuation of Project (contractor's bid price): $ 27,492 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Renovation of single-family home to reduce noise infiltration. This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: replacement of windows with vinyl -framed acoustical windows, installation of secondary aluminum -framed sliding glass storm doors, installation of swing -out aluminum storm doors, installation of chimney -top acoustical dampers at fireplaces and attic insulation. Will there be new rack storage? ❑ Yes Z.. No If yes, a separate permit and plan submittal will be required. Provide AU Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1* Floor 1,237 2"d Floor 3rd Floor Floors thru Basement 1,237 Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: 1,237 Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 1 Other (specify) battery sm/CO Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INF&._.MATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District m ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District m ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline 0... Valley View ❑ .. Renton ❑...Sewer Availability Provided 0 .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 .. Geotechnical Report 0 ...Traffic Impact Analysis ❑ ...Bond 0 .. Insurance 0 .. Easement(s) 0 .. Maintenance Agreement(s) 0 ...Hold Harmless — (SAO) 0 ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank ❑ .. Grease Interceptor O ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization O ...Frontage Improvements 0 .. Pavement Cut ❑ .. Trench Excavation O ...Traffic Control 0 .. Looped Fire Line ❑ .. Utility Undergrounding O ...Backflow Prevention - Fire Protection " Irrigation Domestic Water 0 ...Permanent Water Meter Size... WO # O ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size 0 ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line 2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES a Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTH' :'AGENT: Signature: Print Name: Timot Fenlason Mailing Address: 4000 Delridge y SW, Suite 200 Date: «\ bt 401 Day Telephone: (206) 624-2777 Seattle WA 98106 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0006 Address: 4928 S 113 ST Apn: 3348401741 $1,337.30 DEVELOPMENT $1,298.10 PERMIT FEE R000.322.100.00.00 $784.00 PLAN CHECK FEE R000.345.830.00.00 $509.60 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $39.20 TECHNOLOGY FEE R000.322.900.04.00 $39.20 D14-0007 Address: 4230 S 116 ST Apn: 3347400050 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0008 Address: 4811 S 124 ST Apn: 0179003115 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0009 Address: 12216 47 AVE S Apn: 0179001140 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0010 Address: 5702 S PAMELA DR Apn: 7344000020 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11 Ar SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $30,413.70 D14-0010 Address: 5702 S PAMELA DR Apn: 7344000020 $1,077.20 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0011 Address: 4702 S 124 ST Apn: 0179001210 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0012 Address: 12212 46 AVE S Apn: 0179000910 $1,129.22 DEVELOPMENT $1,096.14 PERMIT FEE R000.322.100.00.00 $661.60 PLAN CHECK FEE R000.345.830.00.00 $430.04 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $33.08 TECHNOLOGY FEE R000.322.900.04.00 $33.08 D14-0013 Address: 11870 44 PL S Apn: 3347400790 $957.70 DEVELOPMENT $929.66 PERMIT FEE R000.322.100.00.00 $560.70 PLAN CHECK FEE R000.345.830.00.00 $364.46 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $28.04 TECHNOLOGY FEE R000.322.900.04.00 $28.04 D14-0014 Address: 4716 S 122 ST Apn: 3347401455 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 l I $32.32 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11 ArIMPARI SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0015 Address: 4920 S 114 ST Apn: 3348401711 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0016 Address: 13049 56 AVE S Apn: 2172000060 $1,285.28 DEVELOPMENT $1,247.61 PERMIT FEE R000.322.100.00.00 $753.40 PLAN CHECK FEE R000.345.830.00.00 $489.71 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $37.67 TECHNOLOGY FEE R000.322.900.04.00 $37.67 D14-0017 Address: 12055 44 AVE S 1 Apn: 3347400420 $657.82 DEVELOPMENT $638.60 PERMIT FEE R000.322.100.00.00 $384.30 PLAN CHECK FEE R000.345.830.00.00 $249.80 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE R000.322.900.04.00 $19.22 D14-0018 Address: 12404 50 PL S Apn: 0179002265 $1,207.26 DEVELOPMENT $1,171.88 PERMIT FEE R000.322.100.00.00 $707.50 PLAN CHECK FEE R000.345.830.00.00 $459.88 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $35.38 TECHNOLOGY FEE R000.322.900.04.00 $35.38 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 DEVELOPMENT $1,323.35 PERMIT FEE R000.322.100.00.00 $799.30 PLAN CHECK FEE R000.345.830.00.00 $519.55 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11 rSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 TECHNOLOGY FEE $39.97 TECHNOLOGY FEE R000.322.900.04.00 $39.97 D14-0020 Address: 12012 44 AVE S Apn: 3347401060 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE 6640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0021 Address: 12020 42 AVE S Apn: 3347400290 $1,493.36 DEVELOPMENT $1,449.57 PERMIT FEE R000.322.100.00.00 $875.80 PLAN CHECK FEE R000.345.830.00.00 $569.27 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $43.79 TECHNOLOGY FEE R000.322.900.04.00 $43.79 D14-0022 Address: 4925 S 125 ST Apn: 0179002840 $1,259.28 DEVELOPMENT $1,222.37 PERMIT FEE R000.322.100.00.00 $738.10 PLAN CHECK FEE R000.345.830.00.00 $479.77 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $36.91 TECHNOLOGY FEE R000.322.900.04.00 $36.91 D14-0023 Address: 1223146 AVE S Apn: 0179000840 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11 grAirill"SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0024 Address: 4702 S 122 ST Apn: 3347401430 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0025 Address: 11608 40TH AVE S Apn: 7340600140 $1,545.38 DEVELOPMENT $1,500.06 PERMIT FEE R000.322.100.00.00 $906.40 PLAN CHECK FEE R000.345.830.00.00 $589.16 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $45.32 TECHNOLOGY FEE R000.322.900.04.00 $45.32 D14-0026 Address: 13007 57TH AVE S Apn: 2137000020 $791.10 DEVELOPMENT $767.96 PERMIT FEE R000.322.100.00.00 $462.70 PLAN CHECK FEE R000.345.830.00.00 $300.76 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $23.14 TECHNOLOGY FEE R000.322.900.04.00 $23.14 D14-0027 Address: 12239 46 AVE S Apn: 0179000830 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 DEVELOPMENT $1,348.59 PERMIT FEE R000.322.100.00.00 $814.60 PLAN CHECK FEE R000.345.830.00.00 $529.49 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $30,413.70 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 TECHNOLOGY FEE $40.73 TECHNOLOGY FEE R000.322.900.04.00 $40.73 M14-0005 Address: 4928 S 113 ST Apn: 3348401741 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0006 Address: 4230 S 116 ST Apn: 3347400050 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0007 Address: 4811 S 124 ST Apn: 0179003115 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102:00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0008 Address: 12216 47 AVE S Apn: 0179001140 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0009 Address: 5702 S PAMELA DR Apn: 7344000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0010 Address: 4702 S 124 ST Apn: 0179001210 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0011 Address: 4928 S 113 ST Apn: 3348401741 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0012 Address: 11870 44 PL S Apn: 3347400790 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0014 Address: 4920 S 114 ST Apn: 3348401711 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0015 Address: 13049 56 AVE S Apn: 2172000060 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0016 Address: 12055 44 AVE S 1 Apn: 3347400420 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100:00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0017 Address: 12404 50 PL S Apn: 0179002265 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11 SYSTEMS rFr- _____ _ -1%LA I4, IQ Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0018 Address: 11836 44 AVE S Apn: 3347401015 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0019 Address: 12012 44 AVE S Apn: 3347401060 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0020 Address: 12020 42 AVE S Apn: 3347400290 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0021 Address: 4925 S 125 ST Apn: 0179002840 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11 kirin"ArSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK I QUANTITY PAID $30,413.70 M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0023 Address: 4702 S 122 ST Apn: 3347401430 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0024 Address: 11608 40TH AVE S Apn: 7340600140 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0025 Address: 13007 57TH AVE S Apn: 2137000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100:00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0026 Address: 12239 46 AVE S Apn: 0179000830 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY I PAID $30,413.70 M14-0030 Address: 11664 44 AVE S Apn: 3347400690 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 TOTAL FEES PAID BY RECEIPT: R1222 $30,413.70 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11 Ow' IV S YSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 bid Project: C�' / iss Type of Inspection: . mil/ 2fAJ - fr---7-/A../r1 L Address: �'/3/(s' '2 / Date Called: Special Instructions: Date Wanted: ` _m-, Requester: Phone No: nApproved per applicable codes. Corrections required prior to approval. COMMENTS: 1Prt), ( ?fib! limp tor; tAt SPECTION FEE RQUIRED. Plior to next inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Datc. G & G SPECIALTY CONTRCTORc 'NC Page 1 of 2 0 Washington State Department of Labor & Industries G & G SPECIALTY CONTRCTORS INC Owner or tradesperson GOODBALLET, JAMES SCOTT Principals GOODBALLET, JAMES SCOTT, PRESIDENT GOODBALLET, TERESA LYNN, SECRETARY GOODBALLET, CHARLES ELMER, CHIEF EXECUTIVE OFFICER WAVY, CHRISTINE, CHIEF OPERATING OFFICER Doing business as G & G SPECIALTY CONTRCTORS INC WA UBI No. 602 975 812 Parent company G & G SPECIALTY CONTRCTORS INC 1221 N. Monde! DR GILBERT, AZ85233 480-921-4079 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GGSPEGS919RT Effective — expiration 12/31 /2009-12/31 /2015 Bond HARTFORD FIRE INS CO Bond account no. 59BSBEA9058 $12, 000.00 Received by L&I Effective date 01 /03/2011 12/18/2010 Bond history Insurance National Union Fire Ins of PA $1,000,000.00 Policy no. xnd0055800 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014 Building Division Public Works • HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0008 DATE: 01/10/2014 PROJECT NAME: Chen Residence SITE ADDRESS: 4811 S 124 St X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Invc 01. ts- l4 Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 02/11/14 Approved with Conditions Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 KI NATIONAL AIRP RT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00860C13 BID PACKAGE M-43 3-53-0058-047 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICALALL INFORMATION IN THE DRAWINGS AND NGLUDING BUT NOT L NVENTILATION. CONTRACT SPECIFICATIONS TO: APPLICABLE YES N O 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEVI VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. 10. INSTALLATION OF CHIMNEY CAP. X II. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WIRING. X SEPARATE PERMIT REQUIRED FOR: 1 Mechanical! Electrical Plumbing Gas Piping City of Tukwila I U;LDQIG DIVISION, FILE4_,COPYnry4 P3rink No. C ti'O ulU Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions ions is acknowledged: BY� D City Of Tl ikwlla UILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: International Fire Code, Internationa I Mechanica I Code ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED 210124. 1!2c, 1'OL2. wyEc. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 201 Aro- City of u iIa BUILDING ISION 0119003115 LEGAL DESCRIPTION: LOTS 23.24, 25 AND 26, BLOCK 14, PLAT OF ALLENTOWN ADDITION TO CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 12 OF PLATS, PAGE 100, IN KING COUNTY, WASHINGTON. DRAWING INDEX T0.0 041.0 A2.0 A2.I A22 A23 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS A2.4 WINDOW FLASHING DETAILS MID LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DU1G INDEX M2.0 MECHANICAL PLANS AND DETAILS EI.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: Sharyn.Parkerskingcounty.gov ARCHITECT: SM. Stemper Architects P.L.L.C. 4000 Delridge Way SUJ, Suite 200 Seattle, WA 98106 Fh: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody LeungE-mail: Jerryesmstemper.com melodyesmstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Fh: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Alt Allaoua E-mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Fh: 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E-mail: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 5. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E-mail: tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. "200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: tfenlasoneJoneepayne.com CMa eda a Jonespa yne.com STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206. 622. 0422 Contact: Ron Martinson E-mail: ronmepem-engineers.com REVISIONS No changes shall be me..do to the scope of work withoi it prior approval of Tukwila Building Division. NOTE: Revs:cns will require a no.,v plan submittal and may include additional plan review fccs. VICINITY MAP (NTS) itfir i LA-000 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DEL$IDGE WAY SW SUITE 200 • 8EATTLE, WA 98106 (206) 624-2777 • FAX (206) 824-2973 0810.03.2535 I;:s's:'l::i=: AUGUST 19, 2013 0 a_ J O_ F"- Q z w i- >- z 0 0 z MPROVEMENTS >- 0 Lu uJ W 0 z LL z 0 0 RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER AIP NUMBER 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER M L&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.O 0810.03.2535 SPECIAL NOTES: 1. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT WERE PRESENT PRIOR TO CONSTRUCTION. 2. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 3. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 4. KNOB AND TUBE WIRING PRESENT. 5. REFERENCE 4/A23 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. 6. THIS RESIDENCE HAS EXISTING WIDE INTERIOR TRIM. NEW TRIM TO MATCH EXISTING INTERIOR TRIM PROFILE. REFERENCE 5/A23 FOR PHOTO. UTILITY FUR UTILITY LOWER FLOOR PLAN 1/4" = 1' L GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. 1-10MEOUJNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 60 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SI-IALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL FOR TIMER LOCATION 1S INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. IS. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE I5 EIGHT HOURS. POWER MUST SE PROVIDED AT RESIDENCE BEFORE 8:00 AM. t AFTER 5:00 P.M. • (E) GAS CONDUIT 'GAS BATH BEDROOM 3 BEDROOM 2 CLOSET CLOSET BEDROOM 1 U BATH 0 KITCHEN DINING ROOM LIVING ROOM (E) METER BOX AND ELECTRICAL WIRES 1 (E) DOWNSPOUT (E) ELECTRICAL WIRES MAIN FLOOR PLAN 1/4" = 1' PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE. DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND OSTORM DOOR REF: DOOR SCHEDULE. OINFILL FRAMING AND PATCH WALL FINISH TO MATCH (E) CONSTRUCTION AT (E) A/C UNIT LOCATION. A/C UNIT TO BE REMOVED. OINSTALL VENT BAFFLE AT (E) ROOF VENT IN ATTIC PER MANUFACTURE'S INSTRUCTIONS. REF: 3/A23 FOR DETAIL. 0 DEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: 1/A23 FOR DETAIL. REF: MECHANICAL DOCUMENTS. OCOORDINATE INSTALLATION OF NEW THERMOSTAT WITH MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. SITTING ROOM REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION A. NORTH ELEVATION B. EAST ELEVATION C. SOUTH ELEVATION D. WEST ELEVATION 10009 LEGEND { ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE W E1 El ACOUSTICAL DOOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION P1-10T0 VIEW NEW THER10STAT TIMER SWITCH FOR BLENDED AIR UNIT rrrmrrnim 8.1 w LLUu w E=9 K=1 E-D u GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT .•E ATTIC ACCESS PANEL i-CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. •11 REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 (DI (GAS ATTIC INSULATION ATTIC INSULATION DAM INSTALL BATTERY OPERATED SMOKE DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER NEW SOFFIT CEILING PATCH WORK • RECEIVE[ CITY OF TUK JAN 09201 PERMIT CEN' ILA 4 ER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 4220 AUGUST 19, 2013 0810.03.2535 0 0 ct z 0 z LU >- z 0 U 0 z AIP NUMBER MPROVEMENTS 3-53-0058-047 Z 0 U 425 2 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES AI.O 0810.03.2535 SPECIAL NOTES: 1. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT WERE PRESENT PRIOR TO CONSTRUCTION. 2. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 0111 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 3. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 II 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 4. KNOB AND TUBE WIRING PRESENT. 5. REFERENCE 4/A23 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION PETAL. 6. THIS RESIDENCE HAS EXISTING WIDE INTERIOR TRIM. NEW TRIM TO MATCH EXISTING INTERIOR TRIM PROFILE. REFERENCE 5/A23 FOR PHOTO. GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL NAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND PETALS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M. L 1 1 11 II 11 I 11 it 11 AA / - - - - - - i - - - - - ; -f I- - - F A E=9 E=9 K=1 K=1 I-r 28'-3" r J 6'-0" ATTIC PLAN 1/4" = 1' PLAN KEYNOTES OI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE. DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND OSTORM DOOR REF: DOOR SCHEDULE. OINFILL FRAMING AND PATCH WALL FINISH TO MATCH (E) CONSTRUCTION AT (E) A/C UNIT LOCATION. A/C UNIT TO BE REMOVED. OINSTALL VENT BAFFLE AT (E) ROOF VENT IN ATTIC PER MANUFACTURE'S INSTRUCTIONS. REF: 3/A23 FOR DETAIL. ODEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: 1/A23 FOR DETAIL. REF: MECHANICAL DOCUMENTS. OCOORDINATE INSTALLATION OF NEW THERMOSTAT WITH MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOINER DRIVEWAY. REVIEWED FOR CODE COMLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION A. NORTH ELEVATION B. EAST ELEVATION C. SOUTH ELEVATION D. WEST ELEVATION LEGEND ❑t ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW NEW THERMOSTAT TIMER SWITCH FOR BLENDED AIR UNIT rR m rr7Trm IL w IJJILW E=9 =1 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. .; .; MATCH (E) TEXTURE AND PAINT 1 =;- ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. � t ; REF. MECH. 4 ELECT. 1 REF. GENERAL NOTE 11 (GAS ATTIC INSULATION ATTIC INSULATION PAM INSTALL BATTERY OPERATED SMOKE DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER NEW SOFFIT CEILING PATCH WORK RECEIV CITY OF TU JAN 0 9 2 PERMIT CE D WILA 014 NTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 9B106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2535 0 J �C z 0 z ct w z KING COUNTY AIP NUMBER MPROVEMENTS >- 0 w w w 0 z U_ U z 3-53-0058-047 z 0 z DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1.1 0810.03.2535 WINDOW TYPES 1. DOUBLE -HUNG 2. HORIZONTAL SLIDER/ FIXED/ SLIDER FIXED XX SLIDER 3. 4. WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A BEDROOM 1 I 2'--1" x 4'-5" STAIN/STAIN I/A2.0 B BEDROOM 1 I 2'-8" x 4'-4" STAIN/STAIN 1/A2.0 C BEDROOM 2 2 4'-I" x 2'-5" STAIN/STAIN 1/A2.0 D BEDROOM 3 2 4'-6" x 2'-6" STAIN/STAIN 2/A2.0 E KITCHEN 2 4'-5" x 2'-5" STAIN/STAIN 1/A2.1 F SITTING ROOM 2 2'-6" x 2'-3" STAIN/STAIN 1/A2.0 G SITTING ROOM 3 1-11" x 2'-2" STAIN/STAIN 1/A2.0 1-1 SITTING ROOM 4 2'-6" x 2'-2" STAIN/STAIN 1/42.0 I LIVING ROOM 2 4'-5" x 3'-11" STAIN/STAIN 1/A2.0 J LIVING ROOM 2 3'-10" x 3'-S" STAIN/STAIN 1/4.2.0 K LIVING ROOM 2 3'-11" x 3'-5" STAIN/STAIN SAFETY GLAZING REQ'D 1/A2.0 L STUDIO 2 3'-4" x 1'-3" STAIN/STAIN SAFETY GLAZING REQ'D 2/A2.1 M STUDIO 2 3'-4" x 1'-3" STAIN/STAIN SAFETY GLAZING REQ'D 2/42.1 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. PRE -PAINTED, GALv SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE HEMMED EDGE E N —J L END CLOSURE HEAD FLASHING DETAIL TYP. 3" = 1' - 0" UNDETERMINED VINYL SIDING SUBSTRATE (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING FOR INSTALLATION of WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SET PRE -PAINTED, GALv SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING UNDETERMINED VINYL SIDING SUBSTRATE VINYL J CHANNEL TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT (E) WOOD FRAME WALL CONSTRUCTION (E) WD. PANELING SELF ADHERING MEMBRANE WINDOW HEAD 1 CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE SEALANT 4 BACKER ROD ltl (E) WD. PANELING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD JAMB LINING SEALANT WINDOW JAMB TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE Co CAREFULLY REMOVE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) L r II SHIM 4 FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT WOOD SILL SOLID WOOD TRIM SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4". CONTINUOUS SEALANT, TYP. WINDOW SILL VINYL SIDING/ WOOD - DETAIL SET 3" = 1' - 0" (E) WD. PANELING (E) VINYL SIDING (E) WOOD FRAME WALL CONSTRUCTION • CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. UNDETERMINED VINYL SIDING SUBSTRATE REMOVE (E) VINYL SIDING FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SET PRE -PAINTED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING UNDETERMINED VINYL SIDING SUBSTRATE VINYL J CHANNEL TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE SEALANT 4 BACKER ROD (E) GWB SELF ADHERING MEMBRANE TOUCH UP PAINT WINDOW HEAD (1 CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD (E) GWB -TOUCH UP PAINT CONTINUOUS SEALANT, TYP. WINDOW JAMB I Li, 000 TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE II II tI r-i t-J 11 CAREFULLY REMOVE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) 0 I II II I SOLID WOOD TRIM WO. JAMB LINING. FINISH TO MATCH (E) BACKER ROD SEALANT SHIM 4 FILL GAP W/ BATT INSULATION 3/4" SEALANT 4 BACKER ROD It WOOD SILL 1 SOLID WOOD TRIM SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4". CONTINUOUS SEALANT, TYP. WINDOW SILL VINYL SIDING/ GWB - DETAIL SET 3"=1'-0" TOUCH UP PAINT (E) GWB RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2535 MPROVEMENTS >- w co w 0 z U Zit co AIP NUMBER 3-53-0058-047 z 0 c� 5. z DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2535 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. HELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. PRE -PAINTED, GALV SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE I" min. min. J HEMMED EDGE END CLoSURE HEAD FLASHING DETAIL TYP. 3" = 1' - 0" (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING PLASHING. UNDETERMINED VINYL SIDING SUBSTRATE REMOVE (E) VINYL SIDING FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SET PRE -PAINTED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBL PER SCHEDULE CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING UNDETERMINED VINYL SIDING SUBSTRATE VINYL J CHANNEL TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED (E) WOOD FRAME WALL CONSTRUCTION II WINDOW HEAD BACKER ROD 4 SEALANT (E) GWB SELF ADHERING MEMBRANE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE SEALANT 4 BACKER ROD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) II (E) GWB (E) CABINETRY WD. JAMB LINING BACKER ROD SEALANT WINDOW JAMB 3/4" SHIM 4 FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD r WOOD SILL SELF -ADHERING MEMBRANE LAP OvER (E) WALL UNDERLAYMENT 4". WINDOW SILL VINYL SIDING/ GWB/ CABINET - DETAIL SET 3"=1'-0" (E) LAMINATE BACKSPLASH (E) GWB (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. UNDETERMINED VINYL SIDING SUBSTRATE REMOVE (E) VINYL SIDING FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SET PRE -PAINTED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE (E) WOOD FRAME WALL CONSTRUCTION ACOUSTICAL WINDOW ASSEMBLY PER WINDOW SCHEDULE BACKER ROD AND SEALANT Il fi WINDOW HEAD LJ TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED EXISTING CONCRETE WALL ACOUSTICAL WINDOW ASSEMBLY PER WINDOW SCHEDULE WINDOW NAIL FLANGE AT SILL, JAMB, 4 HEAD TYP. BACKER ROD AND SEALANT SELF -ADHERING MEMBRANE WINDOW JAMB TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED EXISTING CONCRETE WALL TOUCH UP PANT CONTINUOUS SEALANT, TYP. SHIM 4 FILL GAP W/ BATT INSULATION SOLID WOOD TRIM WD. JAMB LINING SEALANT 4 BACKER ROD REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION D I4Oi?»9 3/4" MIN. SEALANT 4 BACKER ROD 1 4 Ma- • WOOD SILL PT 2X WOOD WRAP AND BLOCKING SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. WINDOW SILL VINYL SIDING/ CONCRETE - DETAIL SET 3"= 1'-0" RECEIVED CITY OF TUKWILA JAN 09 2014 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2535 0 0_ J z LLI o 2 o Z w cn Q w 0 Z J LL g z U � 0 0 <C Z Q LU LU AIP NUMBER MPROVEMENTS 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.1 0810.03.2535 DOOR TYPES 1® 0 ,4 FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM W/ SAFETY GRILLE DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I LIVING ROOM A 3'-0" x 6'-l" STAIN/ STAIN HW-I / 626 DK-4 CAMELOT LOCK -I 1/42.2 2 SITTING ROOM B 2'-1" x 6'-9" STAIN/ STAIN HW-I / 626 DK-4 CAMELOT LOCK -I 2/A2.2 3 LIVING ROOM C 3'-0" x 6'-1" I/A2.2 4 SITTING ROOM C 2'-1" x 6'-S" 2/A2.2 TYPICAL DOOR SCHEDULE NOTES 1. 2. 3. 4. 5. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A ON DOOR TYPES, SCHEDULES & DETAILS SHEET. PRE -PAINTED, GALV SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE 1"mtn. I/"Z." min. i HEMMED EDGE J E N J L END CLOSURE 1(A HEAD FLASHING DETAIL TYP. 3 =1 -0 — - r -"' I�/,�lr-•y.rrl.�rf .�.�rr.il � ,. : . rl �j� � ri//r�r� ,�-r�r. r.L:.L:.. EXISTING SOFFIT AND FRAME WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME 2" MIN. STORM DOOR PER SCHEDULE CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF DOOR 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SEALANT 4 BACKER ROD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR HEAD DOOR JAMB DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE 7��-� ��-"__.... _.........._...._... SILL IN BEAD OF SEALANT DOOR SILL CONT. SEALANT, TYP. SOLID UJOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION WOOD FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) WD. PANELING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID UJOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE VINYL SIDING/ WOOD - DETAIL SET (E) BACKER BOARD (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF DOOR 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SEALANT 4 BACKER ROD SET PRE -PAINTED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING PETAL "A" ON THIS SHEET. CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF DOOR s FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM SEALANT 4 BACKER ROD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE SILL IN BEAD OF SEALANT (E) WOOD FRAME WALL CONSTRUCTION DOOR HEAD 9 2" MIN. SELF ADHERING MEMBRANE (E) WD. PANELING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION WOOD FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 r DOOR JAMB DOOR SILL City of Tukwila BUILDING DIVISION 6 NEL-1 SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE VINYL SIDING/ WOOD - DETAIL SET 3"= 1'-0" RECEIVED CITY OF TUKWIL JAN092014 PERMIT CENTER A S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 AUGUST 19, 2013 0810.03.2535 0 a J Z 0 ct Z w z z 0 0 U z AIP NUMBER MPROVEMENTS >- 0 w co 0 Z LL Lu Lu 3-53-0058-047 0 C9 Z 2 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER M L&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.2 3"= 1'-0" 0810.03.2535 EXISTING VENT COVER EXISTING ROOF VENT EXISTING ROOF STRUCTURE NEW 2"X SPACER e r; CROSS SECTION J .%2". � \ 'ter' • 1 LATERAL SECTION ROOF VENT BAFFLE DETAIL 1 1/2" = 1' - 0" EXISTING ROOF STRUCTURE NEW 2"X SPACER A5 REQUIRED TO PROVIDE 6" CLEAR AIR SPACE 6" MIN. TYPICAL TOP 4 BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. (E) VINYL SIDING CAREFULLY LIFT (E) UJALL UNDERLAYMENT AND INSTALL SELF —ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) VINYL SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING TO MATCH (E) SIDING. PRE —PAINTED, GALV SHEET METAL FLASHING W/ FF. END CAPS UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION HOOD, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION HOOD. REF. MECH.— PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN BEAD OF SEALANT AT EXTERIOR TRIM REPLACEMENT SIDING } i 11 11 11 t t // /// />//�' ///'//:2' 11 11 11 It 1 1 1 I l 1 r I 1 1 UNDETERMINED VINYL SIDING SUBSTRATE f AIR INTAKE DETAIL AT EXTERIOR 3"= 1'-0" CEILING 4" MIN 5E57 HERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. SIDE UJALL (E) FRAMING (E) JOIST DETECTOR INSTALLATION DETAIL TYP. 3"= 1'-0" EXISTING ROOF (E) ROOF FRAMING (E) EAVE VENT. MAY VERY AT EACH PROPERTY. (E) HEAD WINDOW TRIM (E) SILL WINDOW TRIM J,r l arr J, "� J J✓J J��J.r ,�yyJ rrrJ BLOWN IN CELLULOSE INSULATION WITH A COMBINED VALUE OF NOT LESS I:1, INSULATION DAM INSULATION DAM DETAIL 3" = 1' -0" MATCH (E) INTERIOR TRIM PROFILE (E) WALL FRAMING (E) INTERIOR TRIM TYP.b 14- 000 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION . RECEIVED CITY OF TUKWILA S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 fir. ,a: :)z' AUGUST 19, 2013 0810.03.2535 0 0 J z w z z 0 U 0 Z AIP NUMBER MPROVEMENTS >- 0 w 2 w Ct w O z LL UN w 0 LU 3-53-0058-047 z 0 c� z !!% DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.3 NTS JAN 0 9 2014 PERMIT CENTER 0810.03.2535 LIFT (E) WALL UNDERLAYMENT AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY COMERS, TYP. LAP SILL MEMBRANE FLASHING 2-1/2" OVER (E) BLDG. PAPER AT SILL EXTEND I " BEYOND RO. ATEAEND OF SILL. (E) WALL UNDERLAYMENT AT SILL NOTE: CUT (E) SIDING BACK FROM (E) RO. REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. MEMBRANE FLASHING AT SILL (E) SHEATHING CUT SILL FLASHING TO EDGE OF RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF UJALL SHEATHING 1i" MIN 5" k BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. WINDOW NAIL FLANGE EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) UJALL UNDERLAYMENT AT SILL. 4 SCALE: NTS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. 4" TY INSTALL 28 GA. GALV. FLASHING OVER MEMBRANE FLASHING LAPPED MIN. 2" BY (E) SIDING ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION BEND NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. CUT JAMB FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING (E) WALL UNDERLAYMENT 2 MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: GUT (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING REMOVED EDGE OF (E) SIDING, SHOWN D IAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. WHERE REQUIRED, TRIM (E) WALL UNDERLA ENT AT HEAD TO "' PARE FOR INSTA LATION OF HEAD FLA RING AND WINDOW TRI (FOLLOUJI STEPS). L J - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. 3" TYP. 5� SCALE: NTS MEMBRANE FLASHING AT JAMB INSTALL Si -IT. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (E) SIDING, SHOWN D IAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: CUT (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. ALLOW 1/8" BETWEEN FL SOT. EDGE SIDING. CLEARANCE ASHING AND OF (E) (E) UJALL UNDERLAYMENT INSTALL HEAD MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF UJALL) SCALE: NTS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. f Jff/f ffq FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. L a 0 J WINDOW FLASHING INSTALLATION SCALE: NTS r -1 1 \\\\\\ \ , \ \ / L J J SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. J CHANNEL TRIM REQUIRED FOR VINYL SIDING INSTALLATION. LEAVE I/4"-3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REIERED TO 45 "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. TRIM TYPE WILL VARY DEPENDING ON (E) SIDING MATERIAL, FINAL TRIM FINISH SELECTED BY HOMEOWNER REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION I1-0009 RECEIVED CITY OF TUKWILA JAN 0 9 2014 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 9B106 (206) 624-2777 • FAX (206) 824-2973 AUGUST 19, 2013 0810.03.2535 cc 0 d zit Z 0 cc Z W Z Z 0 U C� Z AIP NUMBER MPROVEMENTS >- 0 w w w 0 z J 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.4 HEAD FLASHING PREPARATION SCALE: NTS (8' HEAD FLASHING INSTALLATION SCALE: NTS 9WOOD TRIM INSTALLATION SCALE: NTS PERMIT CENTER 0810.03.2535 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU. AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTU H CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG M FG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL XX A R DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW OR XX EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y /A X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'—O" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 1O'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG—X XxX ABBR S DN I DN I UPI "S+. + r + -q E1 UP VD RA/EA RG —I—) SA SA -M,F— (-I— RA/EA I'I SD > < O—) L;: OR Q EQUIP ID# EA MOD NG NG D 0 • i/% DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 23 26 23 26 N/A 23 26 N/A — MOTOR OPERATED DAMPER 24 1 X X X 1,2 — THERMOSTAT 24 1 X X X 1 REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 — DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE REMARKS WC-1 EXTERIOR 90 337 <.08"WG 7"0 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2535 1170 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXISTING EXTERIOR SIDING AND WINDOW TRIM PAINT. THERMOSTAT/SWITCH HOURS OF OPERATION SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51-51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1 /2) = 90 CFM D LI--0008 RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER 4 RArF �R,gavgNo EXPIRES: 9/08/2014 S.M. STEMPER ARCHITECTS A Aroloaaional T. mitod Ulrab1I14A Company 4000 DELIUDGE WAY SW SUITE 200 ' SEATTLE, WA 96106 (200) 024-2777 ' FAX (200) 024-2973 THE GREENBUSCH GROUP, INC 88•4114)) ACOUSIICN, AUDIO VIDEO & MECHANICAL. ENGINEERING 1900 WEST NEWNEWMAN STREET SUITE 201 SEATRE. WA 95119 (206) 376-0669 (206) 376-0041 FAX 081003.2535 OCe CeCt- LU 0 FT NOISE REMEDY IMPROVEMENTS F—Ig< c7) Lu AIP NUMBER 3-53-0058-047 T U KW I LA WAS H I N G T O N DATE 07/19/2013 ISSUED 100% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX WC-1 -) 90 7"0 U.1..ILI.fY UTILITY 0- JP LOWER FLOOR MECHANICAL PLAN NORTH SCALE: 1 /4" = 1'-0" CEILING FLUE FURNACE z w w OUTSIDE AIR DUCT, SIZE AND ROUTE PER PLAN VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE POC FLOOR OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE BATH (E)SG BEDROOM 3 (E)SG (E)SG BEDROOM 2 CLOSET. CLOSET H L1J 0 BEDROOM 1 (E)SG CLOSET (E)SG (E)RG (E)SIDING (E)AC UNIT LIVING ROOM KITCHEN DINING ROOM N MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1'-0" SHEET METAL FLASHING 2X2 BLOCKING WALL CAP 2X2 BLOCKING 2X BLOCKING (E) RIM JOIST NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. WALL CAP DETAIL SCALE: NONE NORTH JOIST HARD DUCT PER PLAN GAS METER 1. DRAWING NOTES: RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51 SECTION M1507.3.5.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY WAC 51-51, SECTION M1507.3.2. (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51 SECTION M1507.3.2. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51-51 M1507.3.5.1. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. bt'#Oc'09 . RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER EXP I FiREQUIRED 4 S.M. STEMPER ARCHITECTS A PxoCoaal°nal Malted LiabUlily Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 ma) 034-2777 • FAX (900) 0£4-2973 THE GREENBUSCH GROUP, INC 0041100641606 AC0US1CAL. AUDIO NDEO dt MECHANICAL ENOO ERIN9 1000 WEST SIIIFET SUITE T01 SEATILE. WA 9S119 (206) 376-0569 (206) 376-0641 FM 0 ce aC Z 0 Ct Z W Z Z 0 0 0 Z AIP NUMBER 3-53-0058-047 0 z DATE 07/19/2013 ISSUED 100% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA MECHANICAL PLANS AND DETAILS ELECTRICAL_ LEGEND SYMBOL SYMBOL DESCRIPTION DESCRIPTION G LIGHTING OR POWER PANEL BRANCH CIRCUIT WRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. } INDICATES ISOLATED GROUND. MAST, WEA1HERHEAD BRANCH CIRCUIT HOME RUN ELECTRICAL METER CONNEC11ON, SEE EQUIPMENT CONNEC11ON SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNEC11ON NON -FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS AAEQUIPMENT ❑' E ®D i IIII11 o SMOKE DETECTOR TIMER OPERATED SWITCH —�- 11 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. QT THERMOSTAT — - — CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT ® LINE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN 5:00 PM. ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WRING SPECIFICATIONS FOR SWITCH. UTILITY TO FURNACE POWER SUPPLY FUR UTIL TY 5E ROOM 114 E I: ROOM 2 CL 06. T ATf- h CLOT ' r` f' 1 f 1 /' TO FURNACE t DAMPER CL it L /N OOM K TC) N ING ROOM zi tLLfOOOb RECEIVED CITY OF TUKWILA S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 0810.03.2535 UNGINN!NS. INC NM OWN 4WD elNIr, NMI Om TAOOIK WA MIM9.. TilIIOIS ONO NM MOO PAX ONO 42 NOS 0 0 ce J z 0 z ce w z z 0 U 0 z AIP NUMBER MPROVEMENTS >- 0 w w w 0 z v cn ce 3-53-0058-047 DATE August 19, 2013 ISSUED 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN BCR FLOOR PLANS NOTES LOWER FLOOR PLAN 1/4" = 1' MAIN FLOOR PLAN 1/4" = 1' JAN 0 9 2014 PERMIT CENTER SEPARATE 14 PERMIT AND APPROVAL E1.0 0810.03.2535