HomeMy WebLinkAboutPermit D14-0009 - DE MONTALVO RESIDENCE - UPGRADESDE MONTALVO RESIDENCE
12216 47 AVE S
D14-0009
Parcel No:
Address:
Project Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: htto://www.TukwilaWA.eov
DEVELOPMENT PERMIT
0179001140
12216 47 AVE S
DE MONTALVO RESIDENCE
Permit Number: D14-0009
Issue Date: 5/19/2014
Permit Expires On: 11/15/2014
Owner:
Name:
Address:
DE MONTALVO DEBORAH
12216 47TH AVE S , SEATTLE, WA,
98178
Contact Person:
Name: SHARYN PARKER
Address:
7277 PERIMETER RD S, SEATTLE, WA,
98108
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST, PHOENIX, AZ, 85040
License No: GGSPEGS919RT
Lender:
Name: FAA (RANRIP)
Address: RESIDENTIAL AIRCRAFT NOISE
REMEDY IMPROVEMENTS PROGRAM,
Phone: (206) 296-7437
Phone: (480) 921-4079
Expiration Date: 12/31/2015
DESCRIPTION OF WORK:
PROJECT INVOLVES UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE
BUILDING FOOTPRINT OR STRUCTURE. INCLUDES REPLACEMENT OF WINDOWS WITH VINYL -FRAMED
ACOUSTICAL WINDOWS, INSTALLATION OF SECONDARY ALUMINUM -FRAMED SLIDING GLASS STORM DOORS,
INSTALLATION OF SWING -OUT ALUMINUM STORM DOORS, AND INSTALLATION OF CHIMNEY -TOP ACOUSTICAL
DAMPERS AT FIREPLACES AND ATTIC INSTALLATION.
Project Valuation: $22,768.00 Fees Collected: $924.38
Type of Fire Protection: Sprinklers: NO
Fire Alarm: NO
Type of Construction: VB Occupancy per IBC: R-3
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition: 2012 International Fuel Gas Code: 2012
International Residential Code Edition: 2012 WA Cities Electrical Code: 2012
International Mechanical Code Edition: 2012 WA State Energy Code: 2012
Uniform Plumbing Code Edition: 2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
Permit Center Authorized Signature:
Date: OSIA t.l lci
I hearby certify that I have read and e ed this permit and know the same to be true and correct. All
provisions of law and ordinances gover this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: 1 _� Date:
Print Name: /Q le/4P /%94%
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
1
6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A
copy can be obtained at City Hall in the office of the City Clerk.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
0409 FRAMING
0606 GLAZING
0603 ROOF/CEILING INSUL
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Per
Project No.
Date Application Accepted:
Date Application Expires:
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 12216 47th Ave. S.
Tenant Name:
PROPERTY
OWNER
Name:
M O inC' VQ
Address:
City:
State:
Zip:
CONTACT PERSON -- person receiving all project
communication
Name: Sharyn Parker
Address: 7277 Perimeter Road South
City: Seattle State: WA Zip: 98108
Phone: (206) 296-7437 Fax: (206) 269-7315
Email: Sharyn.Parker@kingcounty.gov
GENERAL CONTRACTOR INFORMATION
Company Name: not yet awarded
Address:
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
King Co Assessor's Tax No.: 0179001140
Suite Number: Floor:
New Tenant ❑ Yes m..No
ARCHITECT OF RECORD
Company Name: SM Stemper Architects, PLLC
Architect Name: Timothy Fenlason
Address: 4000 Delridge Way SW, Suite 200
City: Seattle State: WA zip: 98106
Phone: (206) 624-2777 Fax: (206) 624-2973
Email: tfenlason@jonespayne.com
ENGINEER OF RECORD
Company Name:
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: FAA (RANRIP) Residential Aircraft Noise
Address: Remedy Improvements Program
City: State: Zip:
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11 docx
Revised: August 2011
bh
Page I of 4
BUILDING PERMIT INFORMATtt .. - 206-43I-3670
1
Valuation of Project (contractor's bid price): $ 22,768
Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
Renovation of single-family home to reduce noise infiltration. This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: replacement of
windows with vinyl -framed acoustical windows, installation of secondary aluminum -framed sliding glass storm doors, installation
of swing -out aluminum storm doors, installation of chimney -top acoustical dampers at fireplaces and attic insulation.
Will there be new rack storage? ❑ Yes
m.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1" Floor
668
2°d Floor
3rd Floor
Floors thni
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: 668 Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes m No If"yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Other (specify) battery sm/CO
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Z No
If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line\2011 Applications\Pernut Application Revised - 8-9-11. docx
Revised August 2011
bh
Page 2 of 4
PUBLIC WORKS PERMIT INFr,a.MATION — 206-433-0179
Scope of Work (please provide detailed information):
Ca11 before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
m ...Tukwila ❑ ... Water District #125
❑ ...Water Availability Provided
Sewer District
m ...Tukwila
0 ...Sewer Use Certificate
❑ .. Highline
0... Valley View ❑ .. Renton
❑ ... Sewer Availability Provided
0 .. Renton
❑ .. Seattle
Septic System:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage)
0 ...Bond 0 .. Insurance 0 .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way 0
❑ ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
0 ...Sanitary Side Sewer
0 ...Cap or Remove Utilities
O ...Frontage Improvements
0 ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ .. Geotechnical Report
❑ .. Maintenance Agreement(s)
❑ ... Traffic Impact Analysis
❑ ... Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Abandon Septic Tank
❑ .. Curb Cut
❑ .. Pavement Cut
❑ .. Looped Fire Line
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
O ...Permanent Water Meter Size... WO #
0 ...Temporary Water Meter Size .. WO #
❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size
❑ ...Sewer Main Extension Public 0 Private 0
O ...Water Main Extension Public 0 Private 0
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
O ...Water 0 ...Sewer 0 ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:
City
State Zip
Day Telephone:
City
State Zip
H:\Applications\Form -Applications On Line \2011 Applications\Permit Application Revised - 8-9-11. docz
Revised: August 2011
bh
Page 3 of 4
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AU ZED AGENT:
Signature:
Date: 4 am( 2014
Print Name: Tim6fhy Fenlaj Day Telephone: (206) 624-2777
Mailing Address:
4000 Delridge Way SW, Suite 200
Seattle WA 98106
City State Zip
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8.9-11.docx
Revised: August 2011
bh
Page 4 of 4
1
r
ILA
(
IQ
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
D14-0006 Address: 4928 S 113 ST
Apn: 3348401741 $1,337.30
DEVELOPMENT
$1,298.10
PERMIT FEE
R000.322.100.00.00
$784.00
PLAN CHECK FEE
R000.345.830.00.00
$509.60
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$39.20
TECHNOLOGY FEE
R000.322.900.04.00
$39.20
D14-0007 Address: 4230 S 116 ST
Apn: 3347400050 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
D14-0008 Address: 4811 S 124 ST
Apn: 0179003115 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
D14-0009 Address: 12216 47 AVE S
Apn: 0179001140 $924.38
DEVELOPMENT
$897.32
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$27.06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
D14-0010 Address: 5702 S PAMELA
DR Apn: 7344000020 $1,077.20
DEVELOPMENT
$1,045.65
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11
eSYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
D14-0010 Address: 5702 S PAMELA
DR Apn: 7344000020 $1,077.20
TECHNOLOGY FEE
$31.55
TECHNOLOGY FEE
R000.322.900.04.00
$31.55
D14-0011 Address: 4702 S 124 ST
Apn: 0179001210 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0012 Address: 12212 46 AVE S
Apn: 0179000910 $1,129.22
DEVELOPMENT
$1,096.14
PERMIT FEE
R000.322.100.00.00
$661.60
PLAN CHECK FEE
R000.345.830.00.00
$430.04
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$33.08
TECHNOLOGY FEE
R000.322.900.04.00
$33.08
D14-0013 Address: 11870 44 PL S
Apn: 3347400790 $957.70
DEVELOPMENT
$929.66
PERMIT FEE
R000.322.100.00.00
$560.70
PLAN CHECK FEE
R000.345.830.00.00
$364.46
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$28.04
TECHNOLOGY FEE
R000.322.900.04.00
$28.04
D14-0014 Address: 4716 S 122 ST
Apn: 3347401455 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
1
R000.322.900.04.00
$32.32
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11
SYSTEMS
J
r'J�.NILA k`
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
D14-0015 Address: 4920 S 114 ST
Apn: 3348401711 $1,077.20
DEVELOPMENT
$1,045.65
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
13640.237.114
$4.50
TECHNOLOGY FEE
$31.55
TECHNOLOGY FEE
R000.322.900.04.00
$31.55
D14-0016 Address: 13049 56 AVE S
Apn: 2172000060 $1,285.28
DEVELOPMENT
$1,247.61
PERMIT FEE
R000.322.100.00.00
$753.40
PLAN CHECK FEE
R000.345.830.00.00
$489.71
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$37.67
TECHNOLOGY FEE
R000.322.900.04.00
$37.67
D14-0017 Address: 12055 44 AVE S 1
Apn: 3347400420 $657.82
DEVELOPMENT
$638.60
PERMIT FEE
R000.322.100.00.00
$384.30
PLAN CHECK FEE
R000.345.830.00.00
$249.80
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$19.22
TECHNOLOGY FEE
R000.322.900.04.00
$19.22
D14-0018 Address: 12404 50 PL S
Apn: 0179002265 $1,207.26
DEVELOPMENT
$1,171.88
PERMIT FEE
R000.322.100.00.00
$707.50
PLAN CHECK FEE
R000.345.830.00.00
$459.88
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$35.38
TECHNOLOGY FEE
R000.322.900.04.00
$35.38
D14-0019 Address: 11836 44 AVE S
Apn: 3347401015 $1,363.32
DEVELOPMENT
$1,323.35
PERMIT FEE
R000.322.100.00.00
$799.30
PLAN CHECK FEE
R000.345.830.00.00
$519.55
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
D14-0019 Address: 11836 44 AVE S
Apn: 3347401015 $1,363.32
TECHNOLOGY FEE
$39.97
TECHNOLOGY FEE
R000.322.900.04.00
$39.97
D14-0020 Address: 12012 44 AVE S
Apn: 3347401060 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0021 Address: 12020 42 AVE S
Apn: 3347400290 $1,493.36
DEVELOPMENT
$1,449.57
PERMIT FEE
R000.322.100.00.00
$875.80
PLAN CHECK FEE
R000.345.830.00.00
$569.27
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$43.79
TECHNOLOGY FEE
R000.322.900.04.00
$43.79
D14-0022 Address: 4925 S 125 ST
Apn: 0179002840 $1,259.28
DEVELOPMENT
$1,222.37
PERMIT FEE
R000.322.100.00.00
$738.10
PLAN CHECK FEE
R000.345.830.00.00
$479.77
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$36.91
TECHNOLOGY FEE
R000.322.900.04.00
$36.91
D14-0023 Address: 12231 46 AVE S
Apn: 0179000840 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
D14-0024 Address: 4702 5122 ST Apn: 3347401430 $924.38
DEVELOPMENT
$897.32
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$27.06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
D14-0025 Address: 11608 40TH AVE S
Apn: 7340600140 $1,545.38
DEVELOPMENT
$1,500.06
PERMIT FEE
R000.322.100.00.00
$906.40
PLAN CHECK FEE
R000.345.830.00.00
$589.16
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$45.32
TECHNOLOGY FEE
R000.322.900.04.00
$45.32
D14-0026 Address: 13007 57TH AVE S
Apn: 2137000020 $791.10
DEVELOPMENT
$767.96
PERMIT FEE
R000.322.100.00.00
$462.70
PLAN CHECK FEE
R000.345.830.00.00
$300.76
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$23.14
TECHNOLOGY FEE
R000.322.900.04.00
$23.14
D14-0027 Address: 12239 46 AVE S
Apn: 0179000830 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0040 Address: 11664 44 AVE S
Apn: 3347400690 $1,389.32
DEVELOPMENT
$1,348.59
PERMIT FEE
R000.322.100.00.00
$814.60
PLAN CHECK FEE
R000.345.830.00.00
$529.49
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
D14-0040 Address: 11664 44 AVE S Apn: 3347400690 • $1,389.32
TECHNOLOGY FEE $40.73
TECHNOLOGY FEE
R000.322.900.04.00
$40.73
M14-0005 Address: 4928 S 113 ST Apn: 3348401741 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0006 Address: 4230 S 116 ST Apn: 3347400050 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0007 Address: 4811 S 124 ST Apn: 0179003115 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102:00.00
$42.56
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0008 Address: 12216 47 AVE S Apn: 0179001140 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
M14-0009 Address: 5702 S PAMELA
DR Apn: 7344000020 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0010 Address: 4702 S 124 ST
Apn: 0179001210 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0011 Address: 4928 S 113 ST
Apn: 3348401741 $221.32
MECHANICAL
. $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0012 Address: 11870 44 PL 5
Apn: 3347400790 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0013 Address: 4716 S 122 ST
Apn: 3347401455 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$30,413.70
M14-0013 Address: 4716 S 122 ST
Apn: 3347401455 $221.32
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0014 Address: 4920 S 114 ST
Apn: 3348401711 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
,
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0015 Address: 13049 56 AVE 5
Apn: 2172000060 $246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0016 Address: 12055 44 AVE S 1
Apn: 3347400420 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0017 Address: 12404 50 PL S
Apn: 0179002265 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY
PAID
$30,413.70
M14-0018 Address: 11836 44 AVE S
Apn: 3347401015 $246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0019 Address: 12012 44 AVE S
Apn: 3347401060 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0020 Address: 12020 42 AVE S
Apn: 3347400290 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0021 Address: 4925 S 125 ST
Apn: 0179002840 $246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0022 Address: 1223146 AVE S
Apn: 0179000840 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11
a,w
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT QUANTITY
PAID
PermitTRAK $30,413.70
M14-0022 Address: 12231 46 AVE S Apn: 0179000840 $221.32
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0023 Address: 4702 S 122 ST Apn: 3347401430 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0024 Address: 11608 40TH AVE S Apn: 7340600140 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0025 Address: 13007 57TH AVE S Apn: 2137000020 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100:00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0026 Address: 12239 46 AVE S Apn: 0179000830 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
I $8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11
env!,
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT
PermitTRAK
QUANTITY
PAID
$30,413.70
M14-0030 Address: 11664 44 AVE S Apn: 3347400690 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
TOTAL FEES PAID BY RECEIPT: R1222 $30,413.70
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11
SYSTEMS
v1
4
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
D 11-I- Ot;►c
Project:
bF'11Aor3'ALJO
Type of Inspection:
--_rurl t_
Addy�� � � � �� ���
Date Called:
Special Instructions:
Date Wanted:
v�
m
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
A i...)3 __44/ ---,(.,
i
,...t)
i-
1
i7 I '- li>
- )�0Cn%=-1/
ij
3 i
kc' 1
SU it/i,
Ki
t
r:
rati
REINSPECTION FEE QUIRED. Prio to next inspection, fee must be
paid at 6300 Southcente Blvd.. Suite 100. Call to schedule reinspection.
✓,
x
!4
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D14-0009
PROJECT NAME: de Montalvo Residence
SITE ADDRESS: 12216 47 Ave S
X Original Plan Submittal
Response to Correction Letter #,
DATE: 01/10/2014
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division •
Public Works ❑
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 01/14/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Notation:
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 02/11/14
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
G & G SPECIALTY CONTRCTOR" TNIC
C
Page 1 of 2
13 Washington State Department of
Labor & Industries
G & G SPECIALTY CONTRCTORS INC
Owner or tradesperson
GOODBALLET, JAMES SCOTT
Principals
GOODBALLET, JAMES SCOTT, PRESIDENT
GOODBALLET, TERESA LYNN, SECRETARY
GOODBALLET, CHARLES ELMER, CHIEF
EXECUTIVE OFFICER
WAVY, CHRISTINE, CHIEF OPERATING
OFFICER
Doing business as
G & G SPECIALTY CONTRCTORS INC
WA UBI No.
602 975 812
Parent company
G & G SPECIALTY CONTRCTORS INC
1221 N. Mondel DR
GILBERT, AZ85233
480-921-4079
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
GGSPEGS919RT
Effective — expiration
12/31 /2009-12/31 /2015
Bond
HARTFORD FIRE INS CO
Bond account no.
59BSBEA9058
$12,000.00
Received by L&I Effective date
01 /03/2011 12/18/2010
Bond history
Insurance
National Union Fire Ins of PA $1,000,000.00
Policy no.
xnd0055800
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014
KI
TY I�'I
l
NATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00860C13 BID PACKAGE M-43
3-53-0058-047
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
ALL INFORMATION IN THE DRAWINGS AND
MECHSPECIFCIATIONSCAL NTILATION. THE CONTRACT NCLUDING BUT NOT LIMITED TO:
APPLICABLE
YES
YES NO
1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
9. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
10. INSTALLATION OF CHIMNEY CAP.
X
11. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
18. INSTALLATION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL PANEL / SERVICE.
X
20. KNOB AND TUBE WIRING.
X
SEPARATE PE2 1T
REQUIRED FOR:
Mecianical
Electrical
Plumbing
IN Gas Piping
C of Tukwila
P
FILE COPY
Permit No. 1� �1 /4
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions i acknowledged:
City Of lbkwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
4690international Residential Code, 2OIL
International Fire Code,
International Mechanical Code
9.ott litk6sti
0119001140
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
Cityof Tu milli
BUILIN , VISION
LEGAL DESCRIPTION:
THE SOUTH HALF OF LOT 5, ALL OF LOT 6, AND THE NORTH HALF OF LOT 1, BLOCK 6, ALLENTOWN ADDITION TO THE
CITY OF SEATTLE, AS PER PLAT RECORDED IN VOLUME 12 OF PLATS, PAGE 100, RECORDS OF KING COUNTY AUDITOR±
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
41.0 FLOOR PLANS 4 NOTES
A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS
A2.1 DOOR TYPES, SCHEDULE 4 DETAILS
A22 MISCELLANEOUS DETAILS
A23 WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX
M2.0 MECHANICAL PLANS AND DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Shay Parker
E-mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
SM. Stemper Architects P.L.L.G.
4000 Delrldge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody
LeungE-mail: Jerryesmstemper.com
melodyesmatemper.com
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206. 839.0824
Contact: Mohamed Alt Allaoua
E-mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318.0569
Fax: 206.318.0641
Contact: Dylan Turner
E-mail: DylanTegreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E-mail: bcretreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E-mail: tim ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. *200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: tfenlaeonsjonespayne.com
CMa eda onespa yne.com
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206. 622. 0422
Contact: Ron Martinson
E-mail: ronmepsm-engineers.com
REVISIONS �+
No changes shall be made to the scope
of work vvithout prior approve, of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
VICINITY MAP (NTS)
S.MSTEMPER
ARCHITECTS
A Processional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
0810.03.2536
AUGUST 19, 2013
0
a_
ce
J
0
z
w
z
>-
F-
z
0
U
0
z
z
w
2
w
0
a_
>-
cw
w
w
0
z
u_
U
J
w
w
Ct
0
0
z_
F-
RECEIVED
CITY OF TUKWILA
JAN 092014
PERMIT CENTER
AIP NUMBER
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
TO.O
0810.03.2536
01
(E) ELECTRICAL
CONDUIT
(E)18"x18"
ATTIC ACCESS
PANEL
DECK
BEDROOM
KITCHEN
DECK
BATH
NEW 22" x 30"
ATTIC ACCESS
PANEL
SPECIAL NOTES:
I. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT
WERE PRESENT PRIOR TO CONSTRUCTION.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 II 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
3. THIS RESIDENCE HAS EXISTING WIDE INTERIOR TRIM. NEW TRIM TO
MATCH EXISTING INTERIOR TRIM PROFILE. REFERENCE 8/A2.2 FOR PHOTOS.
4. REFERENCE 6/A22 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
MAIN FLOOR PLAN
GENERAL NOTES
1.
CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 FM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT POOR OR WINDOW I5 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON NE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON NE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT I•IOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PA
1/4" = 1'
BEDROOM
2
LIVING
ROOM
A. WEST ELEVATION
28'-0"
•
B. NORTH ELEVATION
r /-/
r
L
NEW 22" x 30"
1 ATTIC ACCESS,
LPANEL
C_
.... LLa
- - 1 I 11
CE)18"x18"
, ?`TIC' ES
L
PLAN KEYNOTES
Ol DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE.
DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
OSTORM DOOR REF: DOOR SCHEDULE.
OINSTALL NEW EXTERIOR SECONDARY SLIDING GLASS DOOR REF: DOOR SCHEDULE.
OINSTALL VENT BAFFLE AT (E) ROOF VENT IN ATTIC PER MANUFACTURE'S INSTRUCTIONS. REF: 4/A22 FOR DETAIL.
OINSTALL VENT BAFFLE AT (E) GABLE END VENT IN ATTIC PER MANUFACTURE'S INSTRUCTIONS. REF: 3/A22 FOR DETAIL.
ODEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: 1/A22 FOR DETAIL. REF: MECHANICAL DOCUMENTS.
OCOORDINATE INSTALLATION OF NEW THERMOSTAT WITH MECHANICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
L
II - I.
41 II
I1 II -
F—a F— LL =JJ F—1
TYP.
P14
ATTIC PLAN
J
1/4" = 1'
4
Aviviann,
C. EAST ELEVATION
1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
D. SOUTH ELEVATION
LEGEND
❑S
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL POOR/ STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
NEW THERMOSTAT
TIMER SWITCH FOR BLENDED AIR UNIT
ITT m rriTrm
U1w11111w
E=9
-9
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
7-71
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
'- ;- ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
• AND WHOLE HOUSE VENT INSTALLATION.
{ ; REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
•
!GAS
ATTIC INSULATION
ATTIC INSULATION PAM
INSTALL BATTERY OPERATED SMOKE
DETECTORS
INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER
NEW SOFFIT
CEILING PATCH WORK
CITY OFRECEIVED TUKVJ
JAN 09201
PERMIT CENT
ILA
ER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
4220
AUGUST 19, 2013
0810.03.2536
ct
0^
J
z
0
>-
z
w
z
z
0
0
0
z
AIP NUMBER
MPROVEMENTS
>-
0
w
w
w
0
z
3-53-0058-047
z
0
c
z
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
CX
NOTES
AI.O
0810.03.2536
TYPICAL WINDOW SCHEDULE NOTES
WINDOW TYPES
///
2.
HORIZONTAL DOUIBLE-HUNG
XX SLIDER
W/ GRIDS
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
KITCHEN
1
5'-0" x 4'-5"
STAIN/STAIN
SAFETY GLAZING REQ'D
I/A2.0
B
KITCHEN
I
2'-II" x 2'-II"
STAIN/STAIN
SAFETY GLAZING REQ'D
2/A2.0
C
KITCHEN
I
3'-0" x 3'-0"
STAIN/STAIN
SAFETY GLAZING REQ'D
3/42.0
D
KITCHEN
1
3'-0" x 3'-0"
STAIN/STAIN
OBSCURED GLASS
3/42.0
E
BEDROOM I
2
2'-II" x 4'-6"
STAIN/STAIN
SAFETY GLAZING REQ'D, OBSCURED GLASS
I/A2.0
F
BEDROOM 2
2
2'-II" x 4'-6"
STAIN/STAIN
OBSCURED GLASS
1/A2.0
G
LIVING ROOM
1
5'-0" x 4'-5"
STAIN/STAIN
1/42.0
H
LIVING ROOM
1
6'-2" x 4'-5"
STAIN/STAIN
SAFETY GLAZING REQ'D
1/A2.0
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
PRE -PAINTED, GALV SHEET
METAL FLASHING W END
CLOSURE. COLOR TO BE
SELECTED IN THE FIELD SLOPE
s
csa
HEAD FLASHING DETAIL TYP.
j 3 = 1 - 0
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL —
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
LIFT (E) WALL UNDERLAYMENT AND
INSTALL WINDOW / NAILING FLANGE
OVER SELF ADHERING MEMBRANE
PENETRATION FLASHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND
LAP UNDER (E) WALL UNDERLAYMENT.
CAULK NEW VERTICAL SIDING JOINTS 4
SET NAIL HEADS FLUSH. PAINT MODIFIED
SIDING TO MATCH (E) SIDING
(E) SIDING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
(E) WOOD FRAME
WALL CONSTRUCTION`
(E) GWB
SELF ADHERING
MEMBRANE
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING
WINDOW HEAD
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
Jill '1
i t� IL
71.
WINDOW JAMB
III II
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
1.7.1
r
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
(E) GUJB
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
28 GA. GALV. FLASHING
OVER LAPPED MIN. 2"
BY (E) SIDING.
WD JAMB LINING
3/4"
•.y...►
rr.
aa'
.ram'
1
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT
SELF -ADHERING
MEMBRANE
(E) GWB
WINDOW SILL
WOOD SIDING/ GWB - DETAIL SET
3"=1'-0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE AND REINSTALL (E) WOOD -
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
(E) WOOD FRAME
\WALL CONSTRUCTION\
r)
i(
NJ
f r
LIFT (E) WALL UNDERLAYMENT AND
INSTALL WINDOW / NAILING FLANGE
OVER SELF ADHERING MEMBRANE
PENETRATION FLASHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND
LAP UNDER (E) WALL UNDERLAYMENT.
CAULK NEW VERTICAL SIDING JOINTS 4
SET NAIL HEADS FLUSH. PAINT MODIFIED
SIDING TO MATCH (E) SIDING
(E) SIDING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
BACKER ROD 4 SEALANT
WINDOW HEAD
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
(E) GUk3
SELF ADHERING
MEMBRANE
(E) CABINETRY
WD. JAMB LINING
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
"IhEVIEWEOR
CODE COMPLIANCE
APPROVED
JAN 3 1. 2014
City o
f Tukwila
DUILDIN 3 ISI9 ..
Ell
WINDOW JAMB
it
trrt
i1
WINDOW SILL
(E) CABINETRY
28 GA. GALV. FLASHING
OVER LAPPED MIN. 2"
BY (E) SIDING.
CONT. SEALANT, TYP.
WD JAMB LINING
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
(E) BACKSPLASH
SELF -ADHERING
MEMBRANE
(E) GWB
WOOD SIDING/ GWB/ CABINET - DETAIL SET
3" = 1' - 0"
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
LIFT (E) WALL UNDERLAYMENT AND
INSTALL WINDOW / NAILING FLANGE
OVER SELF ADHERING MEMBRANE
PENETRATION FLASHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND
LAP UNDER (E) WALL UNDERLAYMENT.
CAULK NEW VERTICAL SIDING JOINTS 4
SET NAIL HEADS FLUSH. PAINT MODIFIED
SIDING TO MATCH (E) SIDING
(E) SIDING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
ACOUSTICAL WINDOW ASSEMBLY
PER SCHEDULE
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE AND REINSTALL (E) WOOD
SIDING FOR INSTALLATION OF NEW
WINDOW ASSEMBLY, TRIM, AND
FLASHING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
(E) WOOD FRAME
WALL CONSTRUCTION
II
WINDOW HEAD
WINDOW JAMB
WINDOW SILL
(E) WD. PANELING
SELF -ADHERING MEMBRANE
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
(E) WD. PANELING
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
28 GA. GALV. FLASHING
OVER LAPPED MIN. 2"
BY (E) SIDING.
WD JAMS LINING
SEALANT
SHIM 4
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
SELF -ADHERING
MEMBRANE
(E) WD. PANELING
WOOD SIDING/ WOOD - DETAIL SET
3"=1'-0"
RECEIVED
CITY OF TUKWILA
JAN092014
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 824-2973
AUGUST 19, 2013
0810.03.2536
0
a_
J
z
0
>-
z
W
z
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
>-
0
w
w
w
0
z
U
F'—
z
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
TYPICAL DOOR SCHEDULE NOTES
(E) SIDING
DOOR TYPES
5
FLUSH SCW FLUSH SCW
W/ WAGON WHEEL HALF-LITE W/
AND 4 PANELS 2 PANELS
W/ SAFETY GLAZING W/ SAFETY GLAZING
W/ OBSERVATION PORT
(MATCH EXISTING MOLDING PATTERN)
C
SECONDARY SLIDING
GLASS DOOR
W/ SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GRILLE
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF SELF
ADHERING MEMBRANE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL HEADS
FLUSH. PAINT MODIFIED SIDING TO MATCH
(E) SIDING
(E) SIDING
(E) WOOD FRAME
WALL CONSTRUCTION
IJ
yl
f
A
DOOR HEAD
28 GA. GALV. FLASHING OVER
LAPPED MIN. 2" BY (E) SIDING.
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF FOR WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-STRIPPING
JAMB BEYOND
DOOR JAMB
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
SILL IN BEAD OF SEALANT
DOOR SILL
SELF -ADHERING
MEMBRANE
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM 4
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
TOUCH UP PAINT
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM 4
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING/ GWB - DETAIL SET
3"=1'-0"
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
LIVING ROOM
A
3'-0" x 6'-8"
STAIN/ STAIN
HW-I / 643E
DK-I ORBIT
LOCK -I
I/A2.1
2
KITCHEN
B
2'-8" x 6'-8"
STAIN/ STAIN
HW-I / 643E
DK-I ORBIT
LOCK-1
2/A2.1
3
BEDROOM 2
C
5'-0" x 6'-8"
STAIN/ STAIN
HW-I / 643E
DK-I ORBIT
LOCK-1
3/A2.1
4
LIVING ROOM
D
3'-0" x 6'-8"
I/A2.1
5
KITCHEN
D
2'-8" x 6'-8"
2/A2.1
(E) SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
SET PRE -PAINTED, GALv SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING TO
MATCH (E) SIDING
(E) SIDING
(E) WOOD FRAME
\WALL CONSTRUCTION\
li f I .
L •
fl
DOOR HEAD
28 GA. GALV. FLASHING OVER
LAPPED MIN. 2" BY (E) SIDING.
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF FOR WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
4
DOOR JAMB
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
• EXISTING FLOOR STRUCTURE
SILL IN BEAD OF SEALANT
DOOR SILL
SELF -ADHERING
MEMBRANE
(E) WD. PANELING
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM 4
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
(E) WD. PANELING
.14
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM 4
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING/ WOOD - DETAIL SET
3"= 1'-0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 31 2014
City Of Tukwila
`I.BONG DIVISION
(E) SIDING
SET PRE -PAINTED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD. REF HEAD
FLASHING DETAIL "A" ON THIS SHEET.
SELF -ADHERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE 15 VISIBLE BELOW
FLASHING EDGE
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND DOOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR FRAME.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
BACKER ROD AND SEALANT
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF DOOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PAINT TO MATCH (E) TRIM
SELF -ADHERING MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
WD. TRIM BEYOND
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
PRE -PAINTED, GALv SHEET
METAL FLASHING W END
CLOSURE. COLOR TO BE
SELECTED IN THE FIELD SLOPE
HEMMED EDGE J
-J
L END CLOSURE
HEAD FLASHING DETAIL TYP.
3"=1'-0"
(E) WOOD FRAME
WALL CONSTRUCTION
SELF -ADHERING MEMBRANE
REMOVE (E) IUOOD SIDING AND
REPLACE. LIFT (E) WALL
UNDERLAYMENT AND INSTALL
SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E)
WALL UNDERLAYMENT OVER TOP
OF PENETRATION FLASHING.
PAINT MODIFIED SIDING TO
MATCH (E) SIDING. TYP. AT HEAD
AND JAMBS
DOOR HEAD
1/2" MIN BETWEEN
PRIMARY AND SECONDARY
SLIDING GLASS DOOR FRAMES
DOOR JAMB
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS.
SEALANT
(E) FLOOR/ DECK FRAMING
n
SOLID WOOD LINING
(E) PRIMARY SLIDING DOOR
ASSEMBLY.
(E) WD. SIDING
LIFT (E) WALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTINUE OVER SLIDING GLASS
DOOR FRAME
SOLID WOOD LINING
(E) PRIMARY SLIDING GLASS
DOOR
(E) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) WD. FLOOR FRAMING
RECEIVED
CITY OF TUKWILA
JAN 0 9 2014
PERMIT CENTER
WOOD SIDING/ GWB - EX. SECONDARY SLIDING DETAIL SET
3" = 1' - 0"
DOOR SILL
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (208) 624-2973
AUGUST 19, 2013
0810.03.2536
0
a_
J
z
O
z
w
>—
F—
z
0
U
(9
z
MPROVEMENTS
>-
Lu
w
LLB
(1)
z
AIP NUMBER
3-53-0058-047
Z
0
0
z
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
EXIST. WALL
CONSTR
EXIST. GABLE
VENT
NEW #" GALV.
HARDWARE
CLOTH
(2) SIMPSON A-34
EACH SIDE PANEL
OPEN TOP
CDX PLYWOOD
AT (3) SIDES
I" OWENS CORNING *103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PLYWOOD
BACK AND SIDE PANEL
NOTE:
I. AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED IN POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OPENING.
31 GABLE END VENT BAFFLE DETAIL
CEILING
BEST HERE
ACCEPTABLE
HERE
NOTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING.
REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND
PAINT TO FILL ALL HOLES LEFT FROM
EXISTING CONDITION. PAINT TO MATCH
SURROUNDING CONDITIONS.
SIDE WALL
DETECTOR INSTALLATION DETAIL TYP.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING. MAINTAIN (E) COURSING. PAINT
MODIFIED SIDING TO MATCH (E) SIDING.
PRE -PAINTED, GALV. SHEET METAL —
FLASHING W/ F.F. END CAPS UNDER
SELF -ADHERING MEMBRANE. PAINT
COLOR TO BE SELECTED IN THE FIELD
PAINT VENTILATION HOOD,
COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION 1400D.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN BEAD OF
SEALANT AT EXTERIOR TRIM
REMOVE / REPLACE (E) SIDING
(i)
BLOWN IN CELLULOSE
INSULATION WITH A COMBINED
VALUE OF NOT LESS THAN
R-38
(E) FRAMING
NEW INSULATION LEVEL
AIR INTAKE DETAIL AT EXTERIOR
(REVERSED)
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
NEW 2"X SPACER
WINDOW TRIM
EXISTING VENT COVER
CROSS SECTION
EXISTING ROOF
STRUCTURE
NEW 2"X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
LATERAL SECTION
ROOF VENT BAFFLE DETAIL
(E) CABINET AT WINDOW TRIM
6" MIN. TYPICAL TOP 4
BOTTOM
NEW 1" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
EXISTING ROOF
(E) ROOF FRAMING
(E) EAVE VENT. MAY VERY
AT EACH PROPERTY.
INSULATION DAM DETAIL
NEW INSULATION LEVEL
(E) HEAD
WINDOW TRIM
(E) SILL
WINDOW TRIM
C
1/2" PAINT GRADE
PLYWOOD, FINISHED TO
MATCH (E) CEILING
CASEMENT SASH LOCKS
BLOWN IN CELLULOSE
INSULATION WITH A COMBINED
VALUE OF NOT LESS THAN, ..
INSULATION DAM
(E) WALL FRAMING
NEW ATTIC ACCESS PANEL DETAIL
MATCH (E) INTERIOR TRIM PROFILE
(E) INTERIOR TRIM TYP.
BATT INSULATION
INSULATION STOP AT
f PERIMETER OF ACCESS
HATCH OPENING, 4 SIDES-
2x IUD BLOCKING
INSTALL 2X BLOCKING
AROUND OPENING AND
FASTEN EDGES OF
DRYWALL TO BLOCKING.
ASSUME (E) CEILING
JOISTS 6 24" O.C. EXTEND
BLOCKING TO (E) CEILING
JOISTS (TYP)
(E) GWB
Ix FLAT STOCK TRIM
FINISHED TO MATCH (E)
CEILING
FIRITE—Vr—D-- FOP.
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JAN 0 9 2014
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
AUGUST 19, 2013
0810.03.2536
AIP NUMBER
MPROVEMENTS
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
MISC.
DETAILS
A2.2
3"=1'-0"
NTS
NTS
0810.03.2536
LIFT (E) WALL
UNDERLAYMENT
AWAY LOOSELY
FROM (E) SHEATHING
AT JAMBS AND HEAD
CORNERS, TYP.
LAP SILL MEMBRANE
FLASHING 2-1/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND I i" BEYOND
RO. AT EA END OF
SILL.
(E) WALL
UNDERLAYMENT
AT SILL
C-D
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
MEMBRANE FLASHING AT SILL
(E) SHEATHING
CUT SILL
FLASHING TO
EDGE OF RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
1i" MIN
5if'
BUTTERFLY CORNER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING
I DNG NOT
SHOWN FOR CLARITY.
MEMBRANE FLASHING
PREVIOUSLY
APPLIED TO WINDOW
OPENINGS.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) WALL
UNDERLAYMENT
AT SILL.
C4
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
4"TY
INSTALL 28 GA. GALV. FLASHING OVER MEMBRANE
FLASHING LAPPED MIN. 2" BY (E) SIDING
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'R$ SPECIFICATIONS.
NOTIFY TECI-IICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
BEND
ANCHORAGE
NAILS DOW
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
REMOVED
SCALE: NTS
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) WALL
UNDERLAYMENT
BACK DOWN
OVER FLANGE
FLASHING AT
JAMBS
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
r
WHERE REQUIRED, TRIM
(E) WALL
UNDERLAYMENT AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
sTEPS).
(E) WALL
UNDERLAYMENT
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
CUT JAMB FLASHING TO
EDGE OF WINDOW OPENING
AS SHOWN. EXTEND I-I/2"
BEYOND EDGE OF
OPENING AT HEAD, JAMBS,
AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
3" TYP.
- INSTALL JAMB FLANGE FLASHING OVER WINDOW -
NAILING FLANGE AND FLASHING.
I5 MEMBRANE FLASHING AT JAMB
} SCALE: NTS
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
ALLOW 1/8"
BETWEEN FL
BOT. EDGE
SIDING.
LEARANCE
SHING AND
(E)
(E) WALL
UNDERLAYMENT
INSTALL HEAD
MEMBRANE FLASHING AT HEAD
CUT HEAD
FLASHING TO
EDGE OF WINDOUJ
OPENING AS
SHOWN. EXTEND
1-1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: CUT (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR
INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS
BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS.
• 3.:_:15,
ZAMTAM
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
L
L
C6.
WINDOW FLASHING INSTALLATION
SCALE: NTS
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL up. TRIM.
APPLY SEALANT BEAD
TO JOINT BETWEEN
WINDOW TRIM AND
SIDING.
J CHANNEL TRIM
REQUIRED FOR VINYL
SIDING INSTALLATION.
LEAVE I/4"-3/8" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS
"SELF ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO A5 "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK
JOINTS. TRIM TYPE WILL VARY DEPENDING ON (E)
SIDING MATERIAL, FINAL TRIM FINISH SELECTED BY
HOMEOWNER
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 3 1 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JAN 0 9 2014
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824-2777 • FAX (208) 824-2973
AUGUST 19, 2013
0810.03.2536
AIP NUMBER
MPROVEMENTS
3-53-0058-047
DATE
AUGUST 19, 2013
ISSUED
100% CD
PROJECT ARCHITECT
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
HEAD FLASHING PREPARATION
SCALE: NTS
( HEAD FLASHING INSTALLATION
} SCALE: NTS
WOOD TRIM INSTALLATION
SCALE: NTS
PERMIT CENTER
ABBREVIATIONS
LEGEND
DRAWING INDEX
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL ABBR
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL ABBR
1282222181
EQUIP ID,
OR
IYI
EA
MOD
NG NG
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
MOTOR OPERATED DAMPER
THERMOSTAT
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
REMARKS
WC-1
EXTERIOR
90
337
<.08"WG
7"0
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2536
670
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51-51-1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
MIN VALUE
NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXISTING EXTERIOR SIDING AND WINDOW TRIM PAINT.
000 i
THERMOSTAT/SWITCH HOURS OF OPERATION
SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51-51, SECTION M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) 4_,1
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 45 / (1 X 1/2) = 90 CFM
RECEIVED
CITY OF TUKWILA
JAN 0 9 2014
PERMIT CENTER
Pp IDV AND
S.M. STEMPER
ARCHITECTS
A Frotr sidonal 14mlted Liability Company
4000 DELRIDGE WAY SW
SUITE 200 ' SEATTLE, WA 08106
(200) 024-2777 • FAX (206) 024-2070
THE GREENBUSCH GROUP, INC
ACOUSTICAL. AU010 VIDEO & MECHANICN. ENGINEERING
1000 MYE.41 SIREEJ SLMIE T01 SEAIILE. MIA 0011Y
(206) 376-0569 (200) 37e-0041 FAX
081003.2536
EDY IMPROVEMENTS
AIP NUMBER
3-53-0058-047
T U KW I LA WAS H I N G TO N
DATE
07/19/2013
ISSUED 100% CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
EXPIRES: 9/08/2014
PATIO
BATH
(E) 18" x 18"
ATTIC ACCESS
PANEL
PATIO
BEDROOM
KITCHEN
)SG
BEDROOM
NEW 22" x 30" 2
ATTIC ACCESS
PANEL
LIVING
ROOM
(E)SG
PATIO
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
POC
NORTH
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
ATTIC PER PLAN
CEILING
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
FLOOR
FURNACE
FLUE
MOD, INTERLOCK
TO FURNACE
(E)SPPLY
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
(E)18"x18'
ATTIC ACCESS I
PANEL
NEW 22" x 3
ATTIC ACCESS
LpANEL
ATTIC MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
FOAM BACKER
ROD, TYP
CAULK, TYP
HARD DUCT
PER PLAN
)() Chi><NN
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
WALL CAP DETAIL
SCALE: NONE
NORTH
(E)SIDING
SHEET METAL
FLASHING
2X2 BLOCKING
WALL CAP
2X2 BLOCKING
2X2 BLOCKING
90
SEE
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51
SECTION M1507.3.5.3.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE
TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT
LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY
WAC 51-51, SECTION M1507.3.2. (CONTROLS FOR WHOLE HOUSE VENTILATION
SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE
FINAL TIME SETTING WITH PROJECT REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT
THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS
"WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC
51-51 SECTION M1507.3.2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET
OF FURNACE RETURN INLET PER WAC 51-51 M1507.3.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE
RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE
OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR.
FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME
DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED.
Sep
Pe 46147*
RECEIVED
CITY OF TUKWILA
JAN 0 9 2014
PERMIT CENTER
S.M. STEMPER
ARCHITECTS
A ProCec01oe1al Limited LiabUlly Company
4000 DELRIDGE WAY SW
SUITE 200 • SEA: TLE, WA 98106
(200) 624-2777 • FAX (206) 024-2973
THE GREENBUSCH GROUP, INC
#A*MAM.O.)
ACOUSTICAL, AUDIO LADED & MECHANICAL ENGINEERING
1900 WEST 140MN SIRED' SUITE 201 SEATILE. WA 98119
(206) 370-0569 (206) 378-0641 FAX
AIP NUMBER
3-53-0058-047
TUKWILA WASHINGTON
DATE
07/19/2013
ISSUED 100%, CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
MECHANICAL
PLANS AND
DETAILS
EXPIRES: 9/08/2014
E L. E CTR I CAL_
LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
G
LIGHTING OR POWER PANEL
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
MAST, WEATHERHEAD
BRANCH CIRCUIT HOME RUN
ELECTRICAL METER
CONNEC11ON, SEE EQUIPMENT CONNEC11ON SCHEDULES
FOR SPECIFIC REQUIREMENTS.
DAMPER CONNEC11ON
La,EQUIPMENT
NON -FUSED DISCONNECT SWITCH
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
SMOKE DETECTOR
TIMER OPERATED SWITCH
THERMOSTAT
U
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
— - —
CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT
®
UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN
5:00 PM.
ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
Lii•• 000l
PATIO
TO FURNACE
POWER SUPPLY
TO FURNACE
DAMPER
RECEIVED
CITY OF TUKWILA
JAN 0 9 2014
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824-2777 • FAX (208) 624-2973
0810.03.2536
AIP NUMBER
MPROVEMENTS
3-53-0058-047
DATE
August 19, 2013
ISSUED
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
BCR
FLOOR
PLANS
NOTES
MAIN FLOOR PLAN
1/4" = 1'
NORTH PERMIT CENTER
E1.0
0810.03.2536