Loading...
HomeMy WebLinkAboutPermit D14-0013 - QUICKSALL RESIDENCE - UPGRADESQUICKSALL RESIDENCE 11870 44 PL S D14-0013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 3347400790 Permit Number: D14-0013 Address: 11870 44 PL S Issue Date: 5/19/2014 Permit Expires On: 11/15/2014 Project Name: QUICKSALL RESIDENCE Owner: Name: QUICKSALL LARRY E Address: 11870 44TH PL S , TUKWILA, WA, 98178 Contact Person: Name: SHARYN PARKER Phone: (206) 296-7437 Address: 7277 PERIMETER RD S, SEATTLE, WA, 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST, PHOENIX, AZ, 85040 License No: GGSPEGS919RT Lender: Name: FAA (RANRIP) Address: RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM, Phone: (480) 921-4079 Expiration Date: 12/31/2015 DESCRIPTION OF WORK: PROJECT INVOLVES UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINT OR STRUCTURE. INCLUDES REPLACEMENT OF WINDOWS WITH VINYL -FRAMED ACOUSTICAL WINDOWS, INSTALLATION OF SECONDARY ALUMINUM -FRAMED SLIDING GLASS STORM DOORS, INSTALLATION OF SWING -OUT ALUMINUM STORM DOORS, AND INSTALLATION OF CHIMNEY -TOP ACOUSTICAL DAMPERS AT FIREPLACES AND ATTIC INSTALLATION. Project Valuation: $23,622.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Fees Collected: $957.70 Type of Construction: VB Occupancy per IBC: R-3 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: 2012 International Fuel Gas Code: 2012 International Residential Code Edition: 2012 WA Cities Electrical Code: 2012 International Mechanical Code Edition: 2012 WA State Energy Code: 2012 Uniform Plumbing Code Edition: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: oc,K I hearby certify that I have read and e -d this permit and know the same to be true and correct. All provisions of law and ordinances gover" ' : this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: Print Nam : pye pAya4'%/Ve_ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 11870 44th P1. S. Tenant Name: PROPERTY OWNER Name: Ciikit( ciV (1, 1 Address: City: State: Zip: CONTACT PERSON - person receiving all pmject communication Name: Sharyn Parker Address: 7277 Perimeter Road South City: Seattle State: WA zip: 98108 Phone: (206) 296-7437 Fax: (206) 269-7315 Email: Sharyn.Parker@kingcounty.gov GENERAL CONTRACTOR INFORMATION Company Name: not yet awarded Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: 3347400790 Suite Number: Floor: New Tenant: ❑ Yes ARCHITECT OF RECORD Company Name: SM Stemper Architects, PLLC Architect Name: Timothy Fenlason Address: 4000 Delridge Way SW, Suite 200 City: Seattle State: WA Zip: 98106 Phone: (206) 624-2777 Fax: (206) 624-2973 Email: tenlason@jonespayne.com EN(;INEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDERBOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: FAA (RANRIP) Residential Aircraft Noise Address: Remedy Improvements Program City: State: Zip: H:Upplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMA'r>rt - 206-431.3670 Valuation of Project (contractor's bid price): $ 23,622 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Renovation of single-family home to reduce noise infiltration. This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: replacement of windows with vinyl -framed acoustical windows, installation of secondary aluminum -framed sliding glass storm doors, installation of swing -out aluminum storm doors, installation of chimney -top acoustical dampers at fireplaces and attic insulation. Will there be new rack storage? ❑ Yes Z.. No If yes, a separate permit and plan submittal will be required. Provide AU Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 911 2°d Floor 833 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: 1,744 Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Other (specify) battery sm/CO Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If `yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Forms-Applications On Line \2011 ApplicationsU'ermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A i T .;. ;1 ZED AGENT: Signature: Date: l Print Name: Timothy Fenlaso Day Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 PUBLIC WORKS PERMIT NFt._.MATION-206-3-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District m ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District m ...Tukwila ❑ ...Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King • ty Health Department. ❑ .. Highline ❑...Valley View ❑ .. Renton CI ...Sewer Availability Provided O .. Renton ❑ .. Seattle Submitted with Application (mark boxes which a i ' I : ❑ ...Civil Plans (Maximum Paper Size — r " x 34") ❑ ...Technical Information Report (Storm 1 : inage) ID.. Geotechnical Report I ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ■ .. Easement(s) ❑ .. Maintenance Agreement(s) 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 7 ours ❑ ...Right-of-way Use - No Disturbance O ...Construction/Excavation/Fill - Right-of-way Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Right-of-way Us rofit for less than 72 hours ID.. Right-of-way .e — Potential Disturbance in Flood Zone ❑ orm Drainage O ...Sanitary Side Sewer 0 .. Abandon S is k ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities 0 .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements 0 .. Pavement • ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped . - Lin- ❑ .. Utility Undergrounding 0 ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # \ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Pu r ❑ Private ❑ ❑ ...Water Main Extension P r lic ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Li Number of Public Fire Hydrant(s) ❑ ...Water 'A ...Sewer 0 ...Sewage Treatment Monthly Service Billi Name: Day Tele . one: Mailing Addr Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Upplications\Forms-Applications On Line \2011 Applications\Pernut Application Revised - 8-9-11. docx Revised: August 2011 bh Page 3 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $30,413.70 D14-0006 Address: 4928 S 113 ST Apn: 3348401741 $1,337.30 DEVELOPMENT $1,298.10 PERMIT FEE R000.322.100.00.00 $784.00 PLAN CHECK FEE R000.345.830.00.00 $509.60 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $39.20 TECHNOLOGY FEE R000.322.900.04.00 $39.20 D14-0007 Address: 4230 S 116 ST Apn: 3347400050 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0008 Address: 4811 S 124 ST Apn: 0179003115 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0009 Address: 12216 47 AVE S Apn: 0179001140 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0010 Address: 5702 S PAMELA DR Apn: 7344000020 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0010 Address: 5702 S PAMELA DR Apn: 7344000020 $1,077.20 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0011 Address: 4702 S 124 ST Apn: 0179001210 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0012 Address: 12212 46 AVE S Apn: 0179000910 $1,129.22 DEVELOPMENT $1,096.14 PERMIT FEE R000.322.100.00.00 $661.60 PLAN CHECK FEE R000.345.830.00.00 $430.04 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $33.08 TECHNOLOGY FEE R000.322.900.04.00 $33.08 D14-0013 Address: 11870 44 PL S Apn: 3347400790 $957.70 DEVELOPMENT $929.66 PERMIT FEE R000.322.100.00.00 $560.70 PLAN CHECK FEE R000.345.830.00.00 $364.46 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $28.04 TECHNOLOGY FEE R000.322.900.04.00 $28.04 D14-0014 Address: 4716 S 122 ST Apn: 3347401455 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 I I $32.32 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11 P,D1 Pr SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $30,413.70 D14-0015 Address: 4920 S 114 ST Apn: 3348401711 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0016 Address: 13049 56 AVE S Apn: 2172000060 $1,285.28 DEVELOPMENT $1,247.61 PERMIT FEE R000.322.100.00.00 $753.40 PLAN CHECK FEE R000.345.830.00.00 $489.71 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $37.67 TECHNOLOGY FEE R000.322.900.04.00 $37.67 D14-0017 Address: 12055 44 AVE S 1 Apn: 3347400420 $657.82 DEVELOPMENT $638.60 PERMIT FEE R000.322.100.00.00 $384.30 PLAN CHECK FEE R000.345.830.00.00 $249.80 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE R000.322.900.04.00 $19.22 D14-0018 Address: 12404 50 PL S Apn: 0179002265 $1,207.26 DEVELOPMENT $1,171.88 PERMIT FEE R000.322.100.00.00 $707.50 PLAN CHECK FEE R000.345.830.00.00 $459.88 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $35.38 TECHNOLOGY FEE R000.322.900.04.00 $35.38 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 DEVELOPMENT $1,323.35 PERMIT FEE R000.322.100.00.00 $799.30 PLAN CHECK FEE R000.345.830.00.00 $519.55 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11 ."?Lo ' SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 TECHNOLOGY FEE $39.97 TECHNOLOGY FEE R000.322.900.04.00 $39.97 D14-0020 Address: 12012 44 AVE S Apn: 3347401060 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0021 Address: 12020 42 AVE S Apn: 3347400290 $1,493.36 DEVELOPMENT $1,449.57 PERMIT FEE R000.322.100.00.00 $875.80 PLAN CHECK FEE R000.345.830.00.00 $569.27 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $43.79 TECHNOLOGY FEE R000.322.900.04.00 $43.79 D14-0022 Address: 4925 S 125 ST Apn: 0179002840 $1,259.28 DEVELOPMENT $1,222.37 PERMIT FEE R000.322.100.00.00 $738.10 PLAN CHECK FEE R000.345.830.00.00 $479.77 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $36.91 TECHNOLOGY FEE R000.322.900.04.00 $36.91 D14-0023 Address: 1223146 AVE S Apn: 0179000840 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $30,413.70 D14-0024 Address: 4702 S 122 ST Apn: 3347401430 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE , $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0025 Address: 11608 40TH AVE S Apn: 7340600140 $1,545.38 DEVELOPMENT $1,500.06 PERMIT FEE R000.322.100.00.00 $906.40 PLAN CHECK FEE R000.345.830.00.00 $589.16 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $45.32 TECHNOLOGY FEE R000.322.900.04.00 $45.32 D14-0026 Address: 13007 57TH AVE S Apn: 2137000020 $791.10 DEVELOPMENT $767.96 PERMIT FEE R000.322.100.00.00 $462.70 PLAN CHECK FEE R000.345.830.00.00 $300.76 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $23.14 TECHNOLOGY FEE R000.322.900.04.00 $23.14 D14-0027 Address: 12239 46 AVE S Apn: 0179000830 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 DEVELOPMENT $1,348.59 PERMIT FEE R000.322.100.00.00 $814.60 PLAN CHECK FEE R000.345.830.00.00 $529.49 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11 (SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 TECHNOLOGY FEE $40.73 TECHNOLOGY FEE R000.322.900.04.00 $40.73 M14-0005 Address: 4928 S 113 ST Apn: 3348401741 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0006 Address: 4230 S 116 ST Apn: 3347400050 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0007 Address: 4811 S 124 ST Apn: 0179003115 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102:00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0008 Address: 12216 47 AVE S Apn: 0179001140 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11 #1111114511441111SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0009 Address: 5702 S PAMELA DR Apn: 7344000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0010 Address: 4702 S 124 ST Apn: 0179001210 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0011 Address: 4928 S 113 ST Apn: 3348401741 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0012 Address: 11870 44 PL S Apn: 3347400790 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11 e SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0014 Address: 4920 S 114 ST Apn: 3348401711 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0015 Address: 13049 56 AVE S Apn: 2172000060 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0016 Address: 12055 44 AVE S 1 Apn: 3347400420 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.10(100.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0017 Address: 12404 50 PL S Apn: 0179002265 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11 OW I SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0018 Address: 11836 44 AVE S Apn: 3347401015 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0019 Address: 12012 44 AVE S Apn: 3347401060 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0020 Address: 12020 42 AVE S Apn: 3347400290 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0021 Address: 4925 S 125 ST Apn: 0179002840 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0022 Address: 12231 46 AVE S Apn: 0179000840 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0022 Address: 12231 46 AVE S Apn: 0179000840 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0023 Address: 4702 S 122 ST Apn: 3347401430 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0024 Address: 11608 40TH AVE S Apn: 7340600140 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0025 Address: 13007 57TH AVE S Apn: 2137000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100:00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0026 Address: 12239 46 AVE S Apn: 0179000830 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 I $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11 ems," SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $30,413.70 M14-0030 Address: 11664 44 AVE S Apn: 3347400690 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 TOTAL FEES PAID BY RECEIPT: R1222 $30,413.70 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11 FSYSTEMS INSPECTION RECORD Retain a copy with permit bi ')3 PERM NO. CITY OF TUKWILA BUILDING DIVISION " 6300 Southcenter Blvd., #100,. Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 nt: L1►€KSAU.- Res d s: 10 Li pis speciaatnstructions: osti iL Pc c' `Typratt s ction: Date Called: Date ted: 'Requester: ae" Approved per applicable codes. Corrections required prior to approval. OOMMENTS: C,LAZrsN JU jr ca 1-t1 =a►t ins Dat PECT1ON FEE RE Q D. Prior to mkt inspection. fee must be at;6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection; ?ERMIT COORD COPY' PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0013 DATE: 01/10/2014 PROJECT NAME: Quicksall Residence SITE ADDRESS: 11870 44 P1 S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Fv C 01-IC-IL{ Building Division Ng Public Works Fire Prevention • Structural Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: -;\ DUE DATE: 02/11/14 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 G& G SPECIALTY CONTRCTOR"NC Page 1 of 2 0 Washington State Department of Labor & Industries G & G SPECIALTY CONTRCTORS INC Owner or tradesperson GOODBALLET, JAMES SCOTT Principals GOODBALLET, JAMES SCOTT, PRESIDENT GOODBALLET, TERESA LYNN, SECRETARY GOODBALLET, CHARLES ELMER, CHIEF EXECUTIVE OFFICER WAVY, CHRISTINE, CHIEF OPERATING OFFICER Doing business as G & G SPECIALTY CONTRCTORS INC WA UBI No. 602 975 812 Parent company G & G SPECIALTY CONTRCTORS INC 1221 N. Monde! DR GILBERT, AZ85233 480-921-4079 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GGSPEGS919RT Effective — expiration 12/31 /2009-12/31 /2015 Bond HARTFORD FIRE INS CO Bond account no. 59BSBEA9058 $12, 000.00 Received by L&I Effective date 01/03/2011 12/18/2010 Bond history Insurance National Union Fire Ins of PA $1,000,000.00 Policy no. xnd0055800 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014 KING OU T I RNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00860C13 BID PACKAGE M-43 3-53-0058-047 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO: APPLICABLE YES NO I. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X 11. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X Is. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WIRING. X SPPARIVIE T E-QUI FEv .J FOR: Mzchanical Elscirical Plumbing Gas Piping r.5:7 of Tukwila FELE C(« Permit No. -).01-7 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions 'a acknowledged: BY Data: City Of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE COPES: Pi i039??nternationaI Residential Code, to - International Fire Code, International Mechanical Code L0tt W4C' 3341400190 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V 6 NON SPRINKLERED REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of ruh BUILDING‘DI LEGAL DESCRIPTION: THE SOUTHEASTERLY 21 FEET OF LOT 13, ALL OF LOT 14, AND THE NORTHWESTERLY 1 FEET OF LOT 15, BLOCK 4, C D HILLMAN'S MEADOW GARDEN ADDITION TO THE CITY OF SEATTLE, DIVISION .1, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 OF PLATS, PAGE 64, IN KING COUNTY, WASHINGTON, EXCEPT THAT PORTION OWNED BY THE NORTHEN PACIFIC RAILWAY DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. A1.0 FLOOR PLANS 4 NOTES A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS 42.1 DOOR TYPES, SCHEDULE 4 DETAILS A22 MISCELLANEOUS DETAILS A23 WINDOW FLASHING DETAILS MI.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206. 296.0190 Contact: Sharyn Parker E-mail: 5haryn.Parkerekingcounty.gov ARCHITECT: SM. Stemper Architects PL.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody LeungE-mail: Jerryesmstemper.com melodyesmstemper.com ACOUSTICAL ENGINEER: 55A Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Ait Allaoua E-mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E-mail: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206. 162. 4180 Contact: Tim Ogden E-mail: tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. "200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: tfeniasonejonespayne.com CMa eda a Jon espa yne.com STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E-mail: ronmepem-engineers.com REVISIONS No changes shell he made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require n row p!an submittal and may inciudo additional plan review fees. VICINITY MAP (NTS) S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIOGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 824-2973 0810.03.2541 AUGUST 19, 2013 0 IZ ec >- J z O .zL W I'- z z O U 0 z MPROVEMENTS >- w/ W W co 0 z u_ LLl 0 RECEIVED CITY OF TUKWiLA JAN 0 9 2014 PERMIT CENTER AIP NUMBER 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.O 0810.03.2541 SPECIAL NOTES: I. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT WERE PRESENT PRIOR TO CONSTRUCTION. 2. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO NAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 II 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 3. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 II 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 4. T14I5 RESIDENCE 1-145 EXISTING WIDE INTERIOR TRIM. NEW TRIM TO MATCH EXISTING INTERIOR TRIM PROFILE. REFERENCE 8/A22 FOR P140T0. 5. REFERENCE 3/A22 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION PETAL. 6. SECURITY ALARM SYSTEM PRESENT. COORDINATE WITH NOMEOILNER FOR TEMPORARY DISCONNECTION AND RECONNECTION OF THE SECURITY SYSTEM PRIOR TO START OF WORK 1. SURPLUS (E) WINDOW 'E' AND (E) ENTRY DOOR TO HOMEOWNER INDOOR PAT I O MAIN FLOOR PLAN 1/4" = 1' GENERAL NOTES I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 FM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOUJ MUST OCCUR ON NE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 60 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 16. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM. DECK TYP. DINING ROOM L i - INSULATION STOP - At PERIMETER . / / - - / / / / / / / / • NEW 24" X 30" ATTIC ACCESS PANEL 1' — 1" STUDY / nr INSULATION STOP I. AT PERIMETER - / / / / / / / / / / / T L L J -11-1" UPPER FLOOR/ATTIC PLAN 1/4" = 1' PLAN KEYNOTES 01 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE. DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND OSTORM 1 DOOR. REF: DOOR SCHEDULE. 0 INSTALL FIREPLACE VENT PER MANUFACTURE'S INSTRUCTIONS, COORDINATE EXACT LOCATION WITH HOMEOWNER 4 O INSTALL VENT BAFFLE AT (E) ROOF VENT IN ATTIC PER MANUFACTURE'S INSTRUCTIONS. PAINT VENT BAFFLES TO MATCH (E) ADJACENT CONDITIONS. REF: 6/422 FOR DETAIL. 0 DEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: 1/A22 FOR DETAIL. REF: MECHANICAL DOCUMENTS. OCOORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS. O COORDINATE WALL GRILL WITH MECHANICAL DOCUMENTS. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF: MECHANICAL DOCUMENTS FOR INSTALLATION DETAIL. OBLENDING UNIT LOCATED AND INSTALLED IN SOFFIT. INSTALL PER MANUFACTURER'S INSTRUCTIONS. REF: MECHANICAL DOCUMENTS 8 FOR UNIT, REF: ELECTRICAL DOCUMENTS FOR SPEED CONTROL AND DISCONNECT. O INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. REF: MECHANICAL AND ELECTRICAL DOCUMENTS. 10 INSTALL NEW ATTIC ACCESS PANEL. REF: 9/A2.2 FOR DETAIL. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. LEGEND REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION A. WEST ELEVATION B. NORTH ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION b\L1ooi3 0 1>pi A El ACOUSTICAL WINDOUJ REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW NEW THERMOSTAT TIMER SWITCH FOR BLENDED AIR UNIT rrrmrnrrm UAW LLU.I W E-9 E-� aI uh. GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A `•:;;; I MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL : ..,-CEILING DEMOLITION FOR ATTIC PANEL ..:1 AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 !GAS ATTIC INSULATION ATTIC INSULATION DAM INSTALL BATTERY OPERATED SMOKE DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS RECEIVED GAS METER CITY OF TUKWILI JANC92014 NEW SOFFIT CEILING PATCH WORK PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (208) 624-2973 yyparliNqI AUGUST 19, 2013 0810.03.2541 MPROVEMENTS >- 0 w 2 w tt w 0 z LL U Q J Q w 0 AIP NUMBER 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES AI.O 0810.03.2541 WINDOW TYPES 1. HORIZONTAL XX SLIDER 2. 3. SLIDER/ FIXED/ SLIDER CASEMENT W/ GRIDS WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A BEDROOM 1 I 6'-2" x 3'-2" SLAIN/SLAIN 1/A2.0 B BEDROOM 2 I 6'-2" x 3'-2" STAIN/STAIN I/A2.0 C KITCHEN I 4'-8" x 2'-8" STAIN/STAIN 1/A2.0 D DINING ROOM 1 5'-8" x 3'-10" STAIN/STAIN I/A2.0 E LIVING ROOM 2 1'-ll" x 3'-11" STAIN/STAIN SAFETY GLAZING REQ'D I/A2.0 F STUDY 3 1'-11" x 3'-4" STAIN/STAIN 1/A2.0 G STUDY 3 I' -II" x 3'-4" STAIN/STAIN 1/A2.0 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. PRE -PAINTED, GALV SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE HEMMED EDGE E -J L END CLOSURE HEAD FLASHING DETAIL TYP. 3" = 1' - 0" CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE AND REINSTALL (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY, TRIM, AND FLASHING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. SET PRE -PAINTED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL "A" ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) SIDING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE BACKER ROD 4 SEALANT WINDOW NAILING FIN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE AND REINSTALL (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY, TRIM, AND FLASHING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. DID-oo13 (E) WOOD FRAME `WALL CONSTRUCTION !1 ii i ♦ WINDOW HEAD 1 • (E) GWB SELF ADHERING MEMBRANE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLIP WOOD TRIM WD. JAMB LINING SEALANT SHIM 4 FILL GAP W/ BATT INSULATION (E) GWB EXTENDED SILL TO MATCH (E) TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM 28 GA. GALV. FLASHING OVER LAPPED MIN. 2" BY (E) SIDING. WD JAMB LINING WINDOW JAMB WINDOW SILL SEALANT SHIM 4 FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT WOOD SILL EXTEND EDGES AT JAMBS TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PAINT SELF -ADHERING MEMBRANE (E) GWB RECEIVED CITY OF TUKWILA S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824-2777 • FAX (206) 824-2973 AUGUST 19, 2013 0810.03.2541 0 cc J Q Z Z W Z 0 Z 0 U C� Z AIP NUMBER MPROVEMENTS >- 0 w w w 0 z U ce 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS WOOD SIDING/ GWB - DETAIL SET 3"=1'-0" JAN 0 9 2014 PERMIT CENTE R A2.0 0810.03.2541 DOOR TYPES E�3 A FLUSH SCUJ HALF-LITE W/ 2 PANELS W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GRILLE DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING ROOM A 3'-0" x 6'-8" PAINT/ PAINT 14W-I / 626 DK-3 JUPITER LOCK -I 1/42.1 2 KITCHEN A 3'-0" x 6'-8" PAINT/ PAINT HW-1 / 626 DK-3 JUPITER LOCK-1 2/A2.1 3 LIVING ROOM B 3'-0" x 6'-8" I/A2.1 4 KITCHEN B 3'-0" x 6'-8" 2/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. 2. 3. 4. 5. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET. PRE -PAINTED, GALY SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE HEMMED EDGE E L END CLOSURE CAD HEAD FLASHING DETAIL TYP. 3 -1 -0 :,' r.. t: .0 ..l..t.:r. EXISTING SOFFIT AND FRAME WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME 2" MIN. STORM DOOR PER SCHEDULE LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) SIDING (E) WOOD FRAME WALL CONSTRUCTION E1 11 DOOR HEAD 2S GA. GALV. FLASHING OVER LAPPED MIN. 2" BY (E) SIDING. CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SH0E 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE SILL IN BEAD OF SEALANT 2" MIN. TOUCH UP PAINT CONT. SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION UJOOD FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. EXISTING FRAMING SOLID WOOD TRIM DOOR JAMB DOOR SILL SHIM 4 FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING/ GWB - DETAIL SET 3"= 1'-0" (E) SIDING CARERJLLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. SET PRE -PAINTED, GALv SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD REF HEAD FLASHING DETAIL "A" ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) SIDING 28 GA. GALY. FLASHING OVER LAPPED MIN. 2" BY (E) SIDING. CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KER= FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING JAMB BEYOND (E) WOOD FRAME WALL CONSTRUCTION SELF -ADHERING MEMBRANE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION WOOD FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID UJOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION 2" MIN. DOOR PER SCHEDULE DOOR JAMB bI'3oor3 WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP t: EXISTING FLOOR STRUCTURE SILL IN BEAD OF SEALANT DOOR SILL RECEIVED WOOD SIDING/ GWB - DETAIL SET CITY OF TUKWILA S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824-2777 • FAX (208) 824-2973 AUGUST 19, 2013 0810.03.2541 rt 0 a J 0 z w z z O U C� Z AIP NUMBER MPROVEMENTS >- 0 cW w W C/) 0 z LL CC W 0 w 3-53-0058-047 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 3"= 1'-0" JAN 09 2014 PERMIT CENTE 0810.03.2541 REMOVE (E) WOOD SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PAINTED, GALV. SHEET METAL - FLASHING W/ FF. END CAPS UNDER SELF -ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION HOOD, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION HOOD. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN BEAD OF SEALANT AT EXTERIOR TRIM REMOVE / REPLACE (E) SIDING BLOWN IN CELLULOSE INSULATION WITH A COMBINED VALUE OF NOT LESS THAN R-38 (E) FRAMING NEW INSULATION LEVEL ti I (. I /r Lit I 11 L. tr i i 1 ri ri / rt 11 1 1 1 1 i 1 i 1 i r 1 1 ; ! 1 AIR INTAKE DETAIL AT EXTERIOR 3 =1 -0 NOTCH TOP PLATE AND TRIM STUDS OF PARTITION TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA TYPICAL EXISTING ROOF (E) ROOF FRAMING (E) EAVE VENT. MAY VERY AT EACH PROPERTY. NEW WALL GRILL COORDINATE WITH MECHANICAL DEMOLISH (E) GWB 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 10 2x2 CONT. NAILER 5/8" GWB- PAINT TO MATCH (E) TEXTURE < COLOR OF WALL TAPE AND FEATHER MUD JOINT (BOTH SIDES) TOUCH UP PAINT ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY DUCT DUCT/ SOFFIT DETAIL 1 1/2" = 1' - 0" (REVERSED VIEW) i' r i• r i � •�'�.r�r'' .. \ / i/ `/ BLOWN IN CELLULOSE INSULATION WITH A COMBINED VALUE OF NOT LESS THAN R-38 EXISTING VENT COVER EXISTING ROOF VENT EXISTING ROOF STRUCTURE NEW 2"X SPACER i CROSS SECTION JATERAL SECTION ROOF VENT BAFFLE DETAIL 11/2"=1'-0" EXISTING ROOF STRUCTURE NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE 6" MIN. TYPICAL TOP t BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. INSULATION DAM DETAIL 3" = 1' -0" EXISTING CEILING/ FLOOR/ ROOF STRUCTURE WHERE WIDTH OF SOFFIT EXCEEDS 16", INSTALL 2X4 STUDS m 16" O.C. GO - PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING (E) ROOF OVERHANG AT WINDOW TRIM NTS INSULATION DAM (E) WALL FRAMING CEILING 4"MIN 1 BEST HERE ACCEPTABLE HERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUND ING COND IT IONS. X 61 SIDE WALL EXISTING CEILING STRUCTURE FINISH TO MATCH (E) PAINT AND TEXTURE METAL CORNER AT GWB CORNERS 3 DETECTOR INSTALLATION DETAIL TYP. 3 = 1 -0 (E) HEAD WINDOW TRIM (E) SILL WINDOW TRIM yfHfr� SNP ....:/�l/.i9hYni MATCH (E) INTERIOR TRIM PROFILE (E) I N'ERIOR TRIM TYP. NTS 117 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City ©f Tukwila BUILDING DIVISION x V 2f DUCT 1 / / 11 11 / / t / 1 1 1 i ANCHOR 2X2 CEILING NAILER TO (E) JOIST • • • • • DUCTS PER PLAN WITHIN SOFFIT RE: MECHANICAL 2x2 CONT. NAILER /a" GWB- PAINT TO MATCH (E) TEXTURE t COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY DUCT/ SOFFIT DETAIL 1 1/2" = 1' - 0" CONTINUOUS WOOD TRIM WOOD FRAME CONTINUOUS (E) WALL CONSTRUCTION WEATHER-STRIPPING WOOD BLOCKING BACKER ROD AND SEALANT CONTINUOUS WOOD TRIM - WOOD FRAME CONTINUOUS WEATHER-STRIPPING TOUCH UP PAINT CONTINUOUS SEALANT, TYP. CONTINUOUS WOOD TRIM DOOR PER SCHEDULE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. CONTINUOUS WOOD TRIM DOOR PER SCHEDULE bI+OO(3 JAMB BEYOND DOOR PER SCHEDULE 7— ATTIC ACCESS PANEL DETAIL 3"=1'-0" RECFIVED CITY OF TUKWILA JAN 0 9 2014 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 422,0 AUGUST 19, 2013 0810.03.2541 0 J z 0 >- z W z F— z 0 U 0 z AIP NUMBER MPROVEMENTS 3-53-0058-047 0 C7 DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.2 PERMIT CENTER 0810.03.2541 LIFT (E) WALL UNDERLAYMENT AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY COMERS, TYP. LAP SILL MEMBRANE FLASHING 2-1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA. END OF SILL. (E) WALL UNDERLAYMENT AT SILL NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. 12" jam (\ MEMBRANE FLASHING AT SILL SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) WALL UNDERLAYMENT AT SILL. C4. (E) SHEATHING CUT SILL FLASHING TO EDGE OF RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 1i" MIN 511 PUTTERFLY CORNER FLASHING NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. 4" TYP. P INSTALL 25 GA. GALV. FLASHING OVER MEMBRANE FLASHING LAPPED MIN. 2" BY (E) SIDING ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECI-INICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION BEND ANCHORAGE NAILS DOUN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING REMOVED SCALE: NTS EDGE OF (E) SIDING, SHOWN D I AGRAMAT I CALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. WHERE REQUIRED, TRIM (E) WALL UNDERLAYMENT AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM FO 0 STEPS). L J (-;- \ HEAD FLASHING PREPARATION SCALE: NTS (E) UJALL UNDERLAYMENT E) INSTALL 514T. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. CUT JAMS FLASHING TO EDGE OF WINDOW OPENING A5 SHOWN. EXTEND 1-I/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE PACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. ALLOW I/5" CLEARANCE BETWEEN FLASHING AND BOT. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) UJALL UNDERLAYMENT INSTALL HEAD MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED WHERE DAMAGE TO SIDING OCCURS. \ \ \ \ \ \ \ i • it/--!-) .; ,; ttr;,r+y(,t s FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. L L J J 6\ WINDOW FLASHING INSTALLATION SCALE: NTS i I L J 9 \ WOOD TRIM INSTALLATION SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL UV. TRIM. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. J CHANNEL TRIM REQUIRED FOR VINYL SIDING INSTALLATION. LEAVE I/4"-3/5" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING 15 SPECIFIED IN 01 62 00 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO A5 "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 5" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. TRIM TYPE WILL VARY DEPENDING ON (E) SIDING MATERIAL, FINAL TRIM FINISH SELECTED BY I-IOMEOWNER REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (208) 824-2973 4111 AUGUST 19, 2013 0810.03.2541 It 0 CL J 0 >- z w z z 0 0 z AIP NUMBER MPROVEMENTS V —J z w C w 3-53-0058-047 z 0 0 z_ F- DATE AUGUST 19, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP H VAC HW HWC HWG HWR H WS IN KW LAT LWG LWT MAX MBH MCA MIN M TG M FG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG, WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE. REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL 4 XX ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE �-- DIRECTION OF FLOW OR XX EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION -S /A- CJ EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG-X XXX ABBR DN + f + UP ±, -lel- el- 0 -) 04'. QOR Q EQUIP i # NG ICI • 0 DN UP VD RA/EA RG SA SA RA/EA SD DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 23 26 23 26 N/A 23 26 N/A BV-1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV-1 140 .5" WG 32"Lx12.25"Wx8.5"H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS SG-1 70 <.08" WG 6" 6" CEILING ALLGRILLE 1, 2, 4 SG-2 70 <08" WG 6" 6" WALL ALGRILLE 1, 2, 4 OG-1 90 <08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG-1 25 <.08" WG 4" 4" CEILING DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN: SHOEMAKER 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL. 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2541 1200 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXISTING EXTERIOR SIDING AND WINDOW TRIM PAINT. THERMOSTAT/SWITCH HOURS OF OPERATION SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51-51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) 4 . &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 F = FRACTION OF OPERATION 1/2 QF=45/(1 X 1/2) = 90 CFM OF EVERY 3 HOURS) = 1 SEPARATE PERMIT AND APPROVAL P-1--cool3 RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER REQUIRED S.M. STEMPER ARCHITECTS A Professional Molted Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 MO 824-2777 FAX (208) 0 4-2973 THE GREENBUSCH GROUP, INC 000 4100) ACOUSNCAL, AUDIO NDEO & MIEc$WIIGN. ENOINEEAING 1900 WEST NICK 5IREET SURE 201 SEATULE, WA YS119 (200) 370-0889 (206) 376-0641 FM 081003.2541 ct 0 rt 0 ct 0 0 EDY IMPROVEMENTS RESIDENTIAL AIRCRAFT NOISE RE AIP NUMBER 3-53-0058-047 TUKWILA WASHINGTON DATE 07/19/2013 ISSUED 100%, CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX EXPIRES: 9/08/2014 INDOOR PATIO CLOSET 1/7/, E`er 25 SEE CEILING GRILLES BEDROOM 2 PATIO SOFFIT, REFER TO ARCHITECTURAL 6"0 UP B A..f.l-H ()0- RG-1 25 BEDROOM 1 SG-1 70 KITCHEN DINING ROOM SEE LA7 n TYP ALL WALL GRILLES (E) WOOD STOVE LIVING ROOM MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" NORTH ATTIC MOTOR AND FILTER ACCESS RETURN AIR DUCT OUTSIDE AIR DUCT 1 SUPPLY AIR DUCT (E)ACCESS PANEL STRAP TO STRUCTURE PER MANUFACTURER'S WRITTEN INSTRUCTIONS. i V- 1�� BV NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH SIZE AND LOCATION WITH ARCHITECT. 1 INSTALLATION DETAIL SCALE: NONE FOAM BACKER ROD, TYP CAULK, TYP SHEETMETAL TRANSITION TO WALL CAP NECK SIZE FLEX DUCT PER PLAN NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. 4" 0 DN TO RG 1 4"0 DN TO RG 1 WALL CAP DETAIL SCALE: NONE L J o0 I — TO TIMER SWITCH NEW 24" X 30" N ATTIC ACCESS PANEL Lk\ SEE SG-2 70 6"0 TYP TYP __1 6"0 DN TO SG-1 STUDY 1 1 ►---- 1 --- -J ATTIC MECHANICAL PLAN SCALE: 1/4" = 1'-0" (E)SIDING SHEET METAL FLASHING 2X2 BLOCKING WALL CAP 2X2 BLOCKING 2X2 BLOCKING SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE AND ESCUTCHEON GRILLE J NORTH DUCT PER PLAN FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST CEILING oN TES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE DETAIL SCALE: NONE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51 SECTION M1507.3.5.3. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK—OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: BV-1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51 SECTION M1507.3.2. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. SHEETMETAL "Y" FITTING WITH VOLUME DAMPERS. CAULK SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN 2X BLOCKING bL'4OOl3 2X BLOCKING FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE DETAIL SCALE: NONE Apprinft 1Tq�� RF��DUq� RFD RECEIVED CITY OF TUKWILA JAN 0 9 2014 PERMIT CENTER S.M. STEMPER ARCHITECTS A Probational Limited Ltebilily Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (200) 624-2777 • FAY (20e) e24-2973 THE GREENBUSCH GROUP, INC *•w••n AOOU59CAL. AU010 N0EO k MECHANICAL ENOINEERINO 1900 WEST SIRFEL SUOE 201 SEAULE, WA a911Y (20e) 37e-0500 (20e) 37e-0041 FAX 081 O 03.2541 0 Ce Q Q Z 0 Q Z LJJ Z Z 0 0 Ca Z se z w w 0 Et 0- CI w w w CO z ca W CD AIP NUMBER 3-53-0058-047 z O C� z DATE 07/19/2013 ISSUED 100% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA MECHANICAL PLANS AND DETAILS EXPIRES: 9/08/2014 W[1 M P PANE P .LO ATION. SERV'iIG LOAD DERIPTII 1: EXISTING LDAD 3 . EXISTING LOAD. EXISTING L 7 EXISTING :LOAD: EXISTING LOAD EXISTIN . LOAD 15 EXISTING :0AD 1` EXISTING LOAD 9 'EXISTING LCAiD SPACE SPACE SPADE SPACE SPACE COMPUTED :LOAD ISOLATED JpRovND B S SIDENCE AI TIGHT T. NE' A 3R. ENGLO+SU RE .: REMARKS TYPE KVA. 401 012 :3012 50t2 01 FEED THRU LU D T IN KR SHUNT TRIP aUL E LUGS:.. ERvicE ENTI VOLT, TF PHASE, 200 AMP With ARE. L:AID DES RII11'1ON:': EXISTING LOAD EXISTII' G LOAD EXISTIN LOAD EXISTING LOAD EXISTINGLOAD XISTIN G LOAI 3 DING UMT SPACE• SPACE E:• SPACE 03 PANEL SKIRTS INTEGRAL Teas 'LUSH 2 14 2 . 24 • SEE FLOOR PLANS FOR LOCATIONS OF BLENDING UNIT AND TIMER SWITCH. 2#12NMB + G, \I OR EQUAL (TYP) E__— PROVIDE GFI DUPLEX RECEPTACLE WHERE BLENDING UNIT IS INSTALLED IN ATTIC SPACE. LOCATE \__ OUTLET WITHIN 24" OF UNIT. PROVIDE LEVITON 9860-BL LIGHT FIXTURE AND SWITCH WHERE BLENDING UNIT IS INSTALLED IN ATTIC SPACE. LOCATE WITHIN 24" OF UNIT. I\_EXISTING PANEL AND SERVICE TO REMAIN. PROVIDE NEW BREAKER, WIRING, DEVICES AND CONNECTIONS AS INDICATED. L_ MP INDooR FAT I c BEDROOM 2 4T UP TO UNIT r) ROOM FAT 0 KITCHEN N NG ROOM (E) WOOD 5TOvE L I'IN OCM ELECTRICAL LEGEND SYMBOL SYMBOL DESCRIPTION DESCRIPTION G LIGHTING OR POWER PANEL EQUIPMENT CONNEC11ON, SEE EQUIPMENT CONNEC11ON SCHEDULES SPECIFIC REQUIREMENTS. DAMPER CONNEC110N NON -FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS ® BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. i INDICATES ISOLATED GROUND. MAST, WEATHERHEAD BRANCH CIRCUIT HOME RUN ELECTRICAL METER IIIIIFOR 0 ❑ OS' ®D l i pT IIII1 } o SMOKE DETECTOR 'TIMER OPERATED SWITCH rEb — - — AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. THERMOSTAT le CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT ® LINE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR DN TO SWITCH ,--NEB '24" X 30:: � ..: ATT C ACCESS PAWL STLIpy- b('fOO(3 SEPARATE AND L REQUIRED RECEIVED CITY OF TUKWILA S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 90106 (208) 624-2777 • FAX (206) 624-2973 0810.03.2541 ■Na1Nl�110. INO We SOWN +.o On err. WI INN TAM A. WA MOMS S raOOUO1O1 OM WI MOO FAX NSW mMM O a a O z w z z 0 U C� Z AIP NUMBER MPROVEMENTS >- 0 w w ct w O Z U 3-53-0058-047 DATE August 19, 2013 ISSUED 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN BCR FLOOR PLANS NOTES ONE LINE DIAGRAM NO SCALE MAIN FLOOR PLAN 1/4" = 1' NORTH UPPER FLOOR/ ATTIC PLAN 1/4" = 1' JAN 0 9 2014 PERMIT CENTER E1.0 0810.03.2541