Loading...
HomeMy WebLinkAboutPermit D14-0034 - KOTIS DESIGN - STORAGE RACKSKOTIS DESIGN 1165 ANDOVER PK W D14-0034 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.sov DEVELOPMENT PERMIT 3523049097 1165 ANDOVER PARK W BLDG B Project Name: KOTIS DESIGN Permit Number: D14-0034 Issue Date: 1/24/2014 Permit Expires On: 7/23/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: CWWA SOUTHCENTER 4 LLC PO BOX B-3879 C/O EQUITY OFFICE MGMT LLC, CHICAGO, WA, 60690 MIKE SORENSON 1100 SW 7TH ST, RENTON, WA, 98057 NORTHWEST HANDLING SYSTEMS 1100 SW 7 ST, RENTON, WA, 98055 NO RTH HS963 N D KOTIS DESIGN Address: 1165 ANDOVER PK W , TUKWILA, WA, 98188 Phone: (206) 818-4488 Phone: Expiration Date: 10/9/2015 DESCRIPTION OF WORK: SUPPLY AND INSTALL (5) BAYS OF NEW PALLET RACKING. SEE ATTACHED ENGINEERING, DRAWINGS AND SUPPLEMENT FOR LOCATION, SPECIFICATIONS, BUILDING INFORMATION AND COMMODITY INFORMATION Project Valuation: $2,300.00 Fees Collected: $257.98 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: Occupancy per IBC: S-2 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: ' ILA L:. Date: I hearby certify that I have read and e . -d this permit and know the same to be true and correct. All provisions of law and ordinances gove his work will be complied with, whether specified herein or not. 2 I� The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ® , Print Name: Date: //2-YA`r This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 10: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or Tess. (IFC 906.3) (NFPA 10, 3-2.1) 11: Maintain fire extinguisher coverage throughout. 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 14: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 15: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 16: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 17: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. ptH, - oo z1 Project No. Date Application Accepted: tt Lis..4z Date Application Expires: k I (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: / (45 j . pK , (/ Tenant Name: Ho fi 5 D25%fon PROPERTY OWNER Name: K aye t�JS tif dyer, Address: 60 l 4 4.4. .r3(Yd s �!' 6' City:1 u le," (4 State ,1 Zip,g /8.e CONTACT PERSON — person receiving all project communication Name: /. l 1 k2.. JUl"e zsaIs„ Address: (,00 sw 7 C S.f . City: RPn^ State: 1�/4. Zip9�,s.7 ,�q Phone: 006 its" IIL6 o Fax:q �aa8'- 6 q'Y6 "' e Email: y►i go rein Susl L n w h S. Co ✓r, GENERAL CONTRACTOR INFORMATION Company Name: / �(1I` i► �Qs/ AAri•_� .c1, jr.I .., o' Address: Limo SW 713, S-,/ City: 1-' / State: aa� � Ziplyar7 Phone: t. 'sacc.opir Fax:v7s_ (fig' 0 v/ N Contr Reg No _ /� /l ,,,?.s.-3-6-Exp Date:, /,/7 ,, Tukwila Business License No.: g vs _ 0 9 9 30,17 King Co Assessor's Tax No.: Suite Number: k7 /q Floor: New Tenant: ❑ Yes 11-.11clo CHITECT OF RECORD Com Name: Architect Na • Address: City: ate: Zip: Phone: Fax: E '. ENGINEER OF RECORD Company Name:Rac , , sir, E,,„t,►o/ 6.0 Engineer Name: /A_ r (94 d U el Address: ,yid IA, , "Fro Lezj Ja,! City: / _teK /' State:C4 Zi /may V'C Phone•pg aMVU'32fO Falg'f)Lv - 3g13 Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Ie '" '2- 4,,,, Address: .S City: State: Zip: H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ c-1 30 0 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Will 4 //LSM`/ CO bajI s of ylew ,Q I let ��US. fG¢al.¢ s,?.e 44i•'t drat,' v �. toce.�`��, s�..rc4.;-, CP � IS, b,`�dt'' 1a.1.) 4 COMA/ ad( Xi .:1'A. Will there be new rack storage? le Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la Floor /5i7`f0 RVO -�� 2nd Floor 3rd Floor Floors thru • Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport l Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ("No If "yes", explain: FIRE PRO)ECTION/HAZARDOUS MATERIALS: L�Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR I7.LYD AGENT: Signature: Print Name: /41 i /� c -kdr!-tJ'c., Mailing Address: / lO 0 .SW' . Date: /7 3/� Day Telephone: jR06 •'.2(g - lives) 98c 7 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9- I l.docx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID D14-0034 61.06 DEVELOPMENT $153.60 PERMIT FEE R000.322.100.00.00 $149.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $7.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R904 R000.322.900.04.00 $7.46 $161.06 Date Paid: Friday, January 24, 2014 Paid By: MICHAELJ SORENSON Pay Method: CREDIT CARD 060913 Printed: Friday, January 24, 2014 10:09 AM 1 of 1 CRSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAI D 4-0 Adder, s: 1165 ANDOVER PART! BLD 2 0490 DEVELOPMENT $96.92 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R722 R000.345.830.00.00 $96.92 $96.92 Date Paid: Tuesday, January 14, 2014 Paid By: MIKE SORENSON Pay Method: CREDIT CARD 00328A Printed: Tuesday, January 14, 2014 10:19 AM 1 of 1 CRIVSYSTEMS INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OFTUKWILA BUILDING .DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 D(4-333-1 Project: Address:- } j 475 4-Akoovu Special Instructions: Type f Inspection:, 1Ju, lei, Date Called: ate Wanted _ ce /.4 • a.m. Requester Phone No: Approved per applicable codes. QCorrections required prior to approval. COMMENTS: REINSPECTION FEE E • 1R ' . Prior to next inspection., fee must .be paid at 6300 Southcenter 81 <:, Suite 100. Call to schedule feinspection. a.m.: p.m. INSPECTION. RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431,-3670 Permit Inspection Request Line (206) 431-2451 Proj t;. SP_S�l�A/ Type Inspection:4 Address: MAJ&cue! /.J COMMENTS: AW Requester: hoe No: s-, e6:41 le d 44 lnsp(Ector: REINSPECTION FEE QU1RED. Prior -to next inspection, fee must be paid at 6300 South nter Blvd., Suite 100. Celt- to schedule reinspe+ction. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: ii// 1(� 5 1The 5,;n Type of Inspection: Az fe- Address: e Suite #: //6( ,410 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. COMMENTS: I I Corrections required prior to approval. XAi >/t• s e, Q� 2 ma's ®„ A/42 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type. Inspector: "H 5,3 Date: Z joy Hrs.: /. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 Field Report Report #: 059335 Client: NorthWest Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055-2939 Contact: Tony Johnson Project Number: 14-153 Permit #: D14-0034 \tl Project Name: Kotis Design Address: 1165 Andover Park W. Bldg. B Inspection Performed: Structural Steel Date: 2/5/2014 Time: Temperature: Verified torque value, 40 ft./lbs., for 1/2" diameter Hilti-KB-TZ quick bolt at one, two bay rack at west side and one, three bay added rack at south side. All work completed per details and manufacturers specifications. RECEIVED CITY OF TUKWILA FEB 2 1 2014 PERMIT CENTER Distribution: Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Blisserd, Jonathan (JD) Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden NORTHWEST HANDLING SYSTEMS, I N C. he Material Handling Experts FILE COPY 1100 SW 7th St Renton, WA 98055 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 1165 Andover Park W. REVIEWED FOR CODE COMPLIANCE TENANT NAME: Kotis Design APPROVED DATE: January 13, 2014 JAN 2 3 2014 APPLICANT: Mike Sorenson / (206) 818-4488 1. Load application and rack configuration drawings attached. City of Tukwila BUILDING DIVISION 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Inspections will be scheduled as instructed. 5. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 6. Commodities stored in racks: Kotis Designs warehouses and distributes promotional clothing. Shirts, sweatshirts, shorts, etc.... with company logos on them. Cotton and poly clothing stored in cardboard boxes directly on racks. 7. Sprinkler System Information: Wet system: 150 psi static, 125 residual. 8. Building exits indicated on attached drawings. bL4003'-i RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER By G. OHANIAN DATE. 1-9-14 SUBJECT RAdK DEOI(dN & EN(INEERINd do. 412 REST BROADWAY, SUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 JOB NO.. RD-17145 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: KOTIS DESIGN 1 165 ANDOVER PARK WEST, BLDG. B TUKWILA, WA 98188 PER IBC 2012 EDITION SECTION 2209 STORAGE RACKS CAPACITY: 3500 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD-17145 PX(Ecop �*MI*A'l w EXPIRES 12-26-15 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION b1M QQ3LJ RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER By G. OHANIAN DATE. 1-9-14 SUBJECT RAdK DEOIdN & EN(INEERIN(4 Co. 412 WEOT BROADWAY, QUITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 2 JOB NO. RD-17145 144" I 04 0) co I co FRONT VIEW BEAM M 01 Lli SEISMIC DESIGN _ Spsxl V— Rx1.4 xW Ix =4.42 Sx =1.44 FY= 55 KSI. SIDE VIEW LOAD PER BEAM + 25% IMPACT LOAD (3.5 Kx.88)+(1.8 Kx.25) = 3.5 = 1.8 K 2 BEAMS M= 82 =32"K SR= .96<1.44 A 384.1x`L =.52"< 180 = .80" •E IBC 2012 (SEC. 2209), RMI SPECS. ASCE 7-10 S os =0.95 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED W=D.L.+ 3 PALLET LOAD LOAD PER COL. = 2x3.5 K —3.5 K 2 cot_ P= .2 DL+ (3.5 Kx0.75)=2.8 K W=.20L+ (3.5PLx0.67)= 2.5 K K LONGIT. •29 V = .43K TRANS. LONGIT. SEISMIC 7 8"K 11.7 K .29K 1 1.7"K BY G. OHANIAN RAdK DEOI(N & EN(dINEERINd do. DATE.1-9-14 SUBJECT 412 WET BROADWAY, BUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 3 JOB NO. RD-17145 COLUMN ANALYSIS 3" x- --x I d 1 M U t=.090" (I Fy=55 KSI Ae=.78 Ix=1.19 Se=.B rx=1.2 ry=1.1 KL= 1.2 84x1.7 _119 Fe= TT2xE =21 rx A c =�FY /Fe = 1.64 (KL)2 rx KL_ ry •52 _47 Fn=Fy(.877)=18 KSI Ac>1.5 �2 M S F 44 c n= a y= Pn— —Fn• Ae = 14.0 K COMBINED STRESS RATIO f1c.P Qb.Cmx.M _ Pex= (KL =17.0 Oc=1.8 Pn + Mn.ax —.90<1 C1cP Qb=1.67 ax=1 Pex = .70 Cmx=.85 BASE PLATE ANCH. TENSION = .63 K ANCHOR SHEAR — .14 K (2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB. HILTI KWIK BOLT—TZ ESR-1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.09x1 x65=2.9 K BEARING CAPACITY OF COL. HOLE 7/16"0 RIVET A=.1 Fy=79KSI Pa = .1x79x.4 = 3 K Ma = (2.9 Kx6")+(2.0 Kx4") = 25.4 "K 4 PIN CONN. CONN. MEND= •01 XWI 2= 2.5 "K M— 9.7"K M— 12.2"K SEISMIC TOTAL 9.7 "K 28K 11.7 ) 7 3/4"x5"x3/8" BASE PLATE I1 6" I 7 3/4" BY G. OHANIAN DATE. 1-9-14 SUBJECT RAdK DEOI(N & EN(INEERINc4 do. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 4 JOB NO.. RD-17145 OVERTURNING MOT =.43 Kx2 x194"x0.66 — =1 1 1 "K COL. MR = 2.8Kx44"= 124"K .43K NO UPLIFT LOAD TO DIAGONAL P=.43Kx2 x5a =1.1K COL. 44 FY =55 KSI Ae=.29 rx =.46 L= 58" Pa= 2.5K CHECK WELDS Pa= 11 .Ol L) L.t.F„ = 5.36 K f7= 2.55 /l -=2.1Kx2 =4.2K SIDES CHECK SLAB 2800 = 2.8 °' 1000 2.8x 144=403 131' VZ=20" M= (12 )2x1000x 2 x12=666 "it S= 12x62 = 72 6 666 = 9 <1.6 N./2500 =80 72 .43 K rn 44" BOTH SIDES TYP TOP LEVEL LOADING W= 0.2DL+1.8LL=2.OK LOAD PER COL. V= .33 K Kx co�168" = 1 12"K MOT = .33 MR = 2.0Kx44"=86"K UPLIFT = 1 144,E - 58 K 1/8 '1.5" t 1-1 t=.06" TYP 1 2800# 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL AND CALCULATIONS ARE IN C. OF THE INTERNATIONAL BUILD 2—STEEL FOR ALL SHAPES FY= 3—NO FIELD WELDING IN THIS - OF THE APPROVED FABRICATO 4—ALL ANCHORS HILTI KWIK BO SPECIAL INSPECTION IS REQU 5—CONCRETE SLAB 6" THICK 2 6—STORAGE RACK CAPACITY: 35 7—RACK INSTALLATIONS SHALL A PERMANENT SIGN OF 50 S. OF THE RACK (3500 #/ LEV; 8—STORAGE RACKS SHALL BE 1'. VERTICAL OF 1/2" IN 10.-0" 9—THE CLEAR SPACE BELOW SP BETWEEN THE TOP OF THE 10—STORAGE RACK AREA NOT STORAGE rum DETM S FNLK0.Isi[r ,n NOM KOTIS DESIGN WEST. NnDL. MM. WI STs RACK DESIGN AND ENGINEERING 112 WEST BROADWAY, SUM I=04, OLENDLLI, CA 1120l Design Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summaryphp?template--min... usGs Design Maps Summary Report User -Specified Input Report Title 1165 ANDOVER PARK WEST, TUKWILA, WA 98188 Fri January 10, 2014 02:27:27 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.43825°N, 122.25513°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.426 g S1= 0.532g SMs = 1.426 g SM1 = 0.798 g Sos = 0.951 g SD1 = 0.532 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please retum to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectrum Design Response Spectrum 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.80 2.00 Period. T (sec) Period, T (sec) Although this information Is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0034 DATE: 01/14/14 PROJECT NAME: KOTIS DESIGN SITE ADDRESS: 1165 ANDOVER PK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Prr i--J Qn't1 Building Division Public Works ❑ Fire Prevention Structural s Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/16/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 02/13/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NORTH WEST HANDLING SYS I"`; Page 1 of 2 05 Washington State Department of Labor & Industries NORTH WEST HANDLING SYS INC Owner or tradesperson FRANCK, JAMES JEROME Principals FRANCK, JAMES JEROME CLARK KOSTY KEVIN THOMAS Doing business as NORTH WEST HANDLING SYS INC WA UBI No. 600 051 641 1100 SW 7TH ST RENTON, WA98055-2939 425-255-0500 KING, County Business type Corporation Governing persons CLARKRKOSTY License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. NORTHWH275JF Effective — expiration 04/06/1973 —10/09/2015 Bond TRAVS Bond account no. 81S103354822BCM Received by L&I 10/09/2001 Insurance Travelers Indemnity Co of Ame Policy no. 6302C242044TIA13 Received by L&1 10/03/2013 Savings No savings accounts during the previous 6 year period. $12,000.00 Effective date 10/01/2001 $1, 000, 000.00 Effective date 10/01/2013 Expiration date 10/01/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641 &LIC=NORTHWH275JF&SAW= 01/24/2014 42'-10" 129' 43'-4" 42' —10" 48X144 48X144 48X144 48X144 48X144 48X144 48X144 48X144 48X144 48X144 12' J TUNNEL BAYS 4 4 48X144 48X144 48X144 48X144 48X144 48X 48X144 48X144 48X144 4 4 48X144 '48X144 48X144 48X144 48X144 4 4 48X144 48X144 3'I 48X144 —3' TYP. le Jr 4' TYP EXIT EXIT PLAN 3,_8„ -6- 3' - 8„ 3'-10" 3'-10" 3'-10" 3'-8„ AREA FOR PENT (ALL OTHERS EXISTING) 44X144 44X144 PLAN VIEW NORTH SCALE: 3/32" = 1'-0" EXIT 1 J 3' 46'-10" SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping (.3.iy of Tukwila DIVISION PLAN NORTH SITE MAP REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. f. 0 : ` fn,, ::ion3 will require a new plan submittal rJ may in.:,'ude additional plan review fees. REVIEWED FOR BOOB COMPLIANCE APPROVED JAN 2 3 2014 City of T ila BUILDING D ISION FILE COPY Permit No. V`A Plan review approval is subject to errors and omissions. Ap ro , of construction documents does not authorize thk v,o!ation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By Date: ,7aY7(y City Of TUkwiia BUILDING DIVISION t'+-Oo 3'/ RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER (2)-1 /2"0 ANCHOR BOLTS PER BASE PLATE 3 1/4" EMB., (SEE NOTE NO. 4) BASE PLATE DETAIL FRONT VIEW SIDE VIEW SEC. A —A t=3/16" 7/16"0 RIVET ASTM A576-90B HOT-L.WROUGHT UNS G10100 GRACE C-1010 4 PIN CONNECTION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION GENERAL CONFIGURATION NOTES; 1—DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2012 EDITION, SECTION 2209 2—STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED) 3—NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #01464 (E70XX ELECTRODES) 4—ALL ANCHORS HILTI KWIK BOLT—TZ ESR-1917 SPECIAL INSPECTION IS REQUIRED 5—CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6—STORAGE RACK CAPACITY: 3500 #/ LEVEL 7—RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (3500 #/ LEVEL) 8—STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10'-0" OF HEIGHT 9—THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 10—STORAGE RACK AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS ONLY EXPIRES 12-26-15 RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 412 WEST BROADWAY SUITE 04 GLENDALE CA. 91204 SCALE: NONE DRAWN BY: AV/ DATE: 12-30-13 PROJECT: KOTIS DESIGN 1165 ANDOVER PARK WEST, BLDG. B, TUKW LA, WA 98188 STORAGE RACK DETAILS IMIMMIEMNRIMMINNIIMMENNONOMMIIMIO JOB NO. RD-17145 SHEET NO.