Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D14-0060 - 100% PURITY COSMETICS - TENANT IMPROVEMENT
100% PURITY COSMETICS 1395 SOUTHCENTER MALL D14-0060 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.eov DEVELOPMENT PERMIT 9202470010 Permit Number: D14-0060 1395 SOUTHCENTER MALL Project Name: 100% PURITY COSMETICS Issue Date: 4/30/2014 Permit Expires On: 10/27/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, CA, 92013 ANDRE WAINWRIGHT 2747 19 ST, SAN FRANCISCO, CA, 94110 TASHCON CORP 710 E MCGLINCY LN #112 , CAMPBELL, CA, 95008 License No: TASHCC*902PQ Expiration Date: 5/16/2015 Phone: (415) 362-5857 Phone: (408) 540-7880 Lender: Name: 100% PURITY COSMETICS Address: ,,, DESCRIPTION OF WORK: NEW TENANT: REMODEL OF EXISTING RETAIL SPACE FOR 100% PURITY COSMETICS TO INCLUDE STOREFRONT AND STORE INTERIORS WITH NEW RESTROOM, WHICH INCLUDES ASSOCIATED ELECT5RICAL, PLUMBING AND MECHANICAL Project Valuation: $65,000.00 Fees Collected: $1,946.32 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: ` I —3V I LI I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: '/�/ ' Date: Print Name: % /Wr This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 18: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 4: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 5: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 7: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 8: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 9: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 13: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 11: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 10: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 14: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 20: Post address on storefront per approved Westfield standards. 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 23: ***BUILDING PERMIT CONDITIONS*** 24: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 25: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 26: New suspended ceiling grid and Tight fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 27: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 28: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 29: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 30: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 31: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 32: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 33: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 34: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 35: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 36: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov it No. b to--OobO Date A Accepted: --,Le) -( i Date Appliciaion Expires: S (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 1395 Southcenter Mall King Co Assessor's Tax No.: Suite Number: 356 Floor: 1 Tenant Name: 100% Purity Cosmetics PROPERTY OWNER Name: Westfield Address: 1395 Southcenter mall City: Seattle State: WA zip: 98188 CONTACT PERSON — perseta receiving all project cconntmication Name: Andre' Wainwright c/o TECTA Associates Address: 2747 - 19th Street City: San Francisco State: CA zip: 94110 Phone: (415) 362-5857 Fax: (415) 362-5044 Email: andrew@tecta.com GENERAL CONTRACT Company Name: T.B.D. Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: New Tenant: ❑ Yes m .. No ARCHITECT OF REGRL) Company Name: TECTA Associates Architect Name: Ahmad Mohazab Address: 2747 - 19th Street City: San Francisco State: CA Zip: 94110 Phone: (415) 362-5857 Fax: (415) 362-5044 Email: ahmad@tecta.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: 9 for projects S5,000 or ). Name: 5t.t, r rip.,b6.� i/ c.' J'u Address: City: State: Zip: H.\Applications \Forms -Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 1docx Revised: August 2011 bh Page I of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 65,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Remodel of existing retail space to new retails space for 100% Purity Cosmetics to included storefront and store interiors with new restroom. which includes associated electrical, plumbing and mechanical. Will there be new rack storage? El Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below • Interior Remodel Addition to Existing Structure New Type of Conshuction per IBC Type of Occupancy per IBC l°Floor 967 967 0 0 2B M 2nd Floor 3r4 Floor Floors thra Basement Accessory * Attached Gamge Detached Garage Attached Carport Detached Carpcat Covered Deck Uered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes FIRE PI;OTECTION/HAZAI;DOUS MATERIALS: Sprinklers Automatic Fire Alarm El No If -yes", explain: ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\201 I Applications \Permit Application Revised - 8-9-11. docx Revised: August 201 I bh Page 2 of 4 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to r hlic Works Bulletin #1 for fees and estivate sheet. Water District ❑ ...Tukwila ❑ ... Water District # 125 0 ...Water Availability Provided Sewer District ❑ ...Tukwila O ...Sewer Use Certificate ❑ ... Valley View ❑ ...Sewer Availability Provided ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which anulv): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") O ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report 0 ...Traffic Impact Analysis 0 ...Bond 0 .. Insurance 0 .. Easement(s) 0 .. Maintenance Agreement(s) 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill El ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance cubic yards ❑ .. Work in Flood Zone cubic yards ❑ .. Storm Drainage 0 ...Sanitary Side Sewer 0 ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation ❑ .. Abandon Septic Tank ❑.. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line Domestic Water ❑ ...Permanent Water Meter Size... " ❑ ...Temporary Water Meter Size .. 0 ...Water Only Meter Size " ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ WO # WO # WO # Private ❑ Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding 0 ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1I.doex Revised: August 2011 bh Page 3 of 4 • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO . Z AGENT: Signature: 4/" Date: 2/7-0/7/ 5. /U ,/ 2G / ? ✓t°l Print Name: /r�`/Uf�/ %�l/�I SAY/ Day Telephone: D �� �`J Mailing Address: 26 42 /4 2Q. �a/X49e Ctty - statec___- . UG Zip H:\Applications\For s-Applications On Line \2011 Applications\Perntit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK I PAID $1,203.86 D14-0060 Address: 1395 SOUTHCENTER MALL Apn: 9202470010 $1,203.86 DEVELOPMENT $1,146.75 PERMIT FEE R000.322.100.00.00 $1,142.25 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $57.11 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1942 R000.322.900.04.00 $57.11 $1,203.86 Date Paid: Monday, April 28, 2014 Paid By: TASHCON CORPORATION Pay Method: CHECK 2656 Printed: Monday, April 28, 2014 1:48 PM 1 of 1 DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY I PAID D14-0060 Address: 1395 SOUTHCENTER MALL Apn: 9202470010 $742.46 DEVELOPMENT $742.46 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1294 R000.345.830.00.00 $742.46 $742.46 Date Paid: Thursday, February 20, 2014 Paid By: TECTA ASSOCIATES Pay Method: CHECK 14482 Printed: Thursday, February 20, 2014 2:42 PM 1 of 1 SYSTEM; INSPECTION RECORD Retain a copy with permit PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 431-2451 Project % ?tt Type of Inspection: F ( r� v L.-6L.,�.W IQ Ad (5 c SC__ A14 (! Date Called: S11.SPfNaF©dEIGy� Date Wanted: 6 ,,,,., t 1.► j Li a.m. p:m. Special Instructions: Request r ; o ?40q Approved per applicable codes. a Corrections required prior to approval. COMMENTS: O(L-,Azi , appie\pczcv Date SPECTION FEE REQUIRE to next inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4 INSP T INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project b 0c ifE Type of Inspection: Add pt4 elLt.. Date Called: Special instructions: Date W nted: 1 �j t 11 ...� Cj en. Requester: F 0 14 P Ph N to B`10 - � `7 q ii QApproved per applicable codes. Corrections required prior to approval. COMMENTS: 17 Z-Aili1J — t (d frb QLl�,T0r1.01 C- AZT�C....- / D te: • 1.Ao_03 (L. e. — 1 — R NSPECTION FEE (WIRED. Prior to/next inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. INS}ECTION RECORD Retain a copy with permit 1-1 -ct6o PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro; t o oci0 tr, .1Li Typo ITA+fY1 1\1 V Address- ki45 ��' ` ` Date Called: Special Instructions: DateWanted: 2— -- G p.m. Req ester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS. , A S A-AN:4 (. - /c Svuzic 0 e1(c( c *%(241 Date SPECTION FEE RE P l IRE. Prior1to next inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. y. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER bpf .... o0 6 PERMIT NUMBERS CITY OF, TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: lod Arz-e_. }_"` Tyw of Inspepttpni r r Address: l3''S' Suite #: S.L. ( U. - Contact Person: Special Instructions: Phone No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: c"-?._ Date: 6//'2/,1/ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule.a reinspection. Billing Address Attn: Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS. CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: . b7oQvre Type of Inspection: FtA, Address Suite #: 13 c 15..ir C , JV\o.v1 Contact Person: Special Instructions: Phone No.: rov`I papplicabl odes.&= t COMMENTS: 45. ek Corrections required prior to approval. Skz -Fc bv'k vvAa/\\ 5�� .. c! ckrOVA v,(� VAS k ► i t&f 40 \; .���a, t� (C�.na`.. ��Q.r�`� CC o�,s wvovvl' tvy Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct Monitor. / Pre -Fire: Permits:.Occupancy Type: Inspector Y v 5k. Date: Li tak k Hrs.: n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: . ioa9, tx/-c., Type of Inspection: 5 e 00 v-e_te— Addre Suite #: �� S� S.. r�►'L% Contact Person: Special Instructions: Phone No.: 1;7 Approved per applicable codes. COMMENTS: Nv �qa/S one nCorrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: c-- e)---- Date: 6 f/6/tV Hrs.: / n $100.00 REINSPECTION FEE REQUIRED. You wil( receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER w - ©00 /9- 5- /I1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: m /Dd ° ?ccre. Type of ns ion: 51} CUB Address: , /�/r_ Contact Person: 1 4 I j� s. Suite #: Special Instructions: Phone No.: I I Approved per applicable codes. COMMENTS: oK I I Corrections required prior to approval. Coves A4J /k Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: Hrs.: n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: City: - ..Word/Inspection Record Form.Doc Company Name: State: Zip: T.F.D. Form F.P. 113 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Re vised June 2013 Project Info Project Address 100% PORE, wasTrIHLD SOUTNCENTER Date 4/1/2014 1395 SOUTH CENTER SPACE 6 356 For Building Dept. Use SEATTLE, NA 98166 Applicant Name: ANN110 NoaAEAB Applicant Address: 2747 19TR STREET, SAN FRANCISCO, CA 94110 Applicant Phone: 415-362-5857 Project Brieftydescribe system type Description mechanical and features. Plans Replacing existing unit, including duct i n capacities unit and new ductwork. 'PILEeory Permit No. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 ri Includes Compliance Option leSimple System Q Complex System Q Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Nam& Model No.' Capaolty2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptione Heat Recovery Y/N HP-1 HEAT 21.00 YORK XP-036 35000 300 13 N Y N • Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency' Heat Recovery YIN HP-1 HEAT NAM YORE XP-036 34800 300 3 Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM Sp' HP/BHP Flow Controls Location of Service REVIEWED FOI CODE CQMPLIAN APPROVED Service Water Heating Equipment Schedule 20�4 Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub- Category EF7 APR 1 Location of Service NH-1 ELECT CNRONONITE BR-20L 2.4KW 0.95 LAv 6 SINE City ofTukwils BUILDING DIMS ' If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). If required. 4 COP, HSPF, Combustion Efficiency. or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). a Economizer exception number per RECEIVED CITY OF TUKWILA CORRECTION LTR#...�...Z.�..... p [-kOO(pO APR 0 3 2014 PERMIT CENTER e Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and » 3 stay R2 and R3 Revised June 2013 Project Address 100%PURE, WESTFIELDSOUTHCENTER Date 4/1/2014 The following information is necessary 10 check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area In Excel prior to printing MECH-CHI( pages. Applicability (yes,no,ne) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance C403.2.1 Load calculationsLoad calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 C403.2.2 Equipment and system sizing Output capacity ot (heating and cooling equipment and systems do not exceed calculated roads, note exceptions taken Yesventilation C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per MC; indicate mechanical is capable of being reduced to minimum requirement per MC M 1 Yes C403.2.3 & C403.2.3.2 & C403.2.12.1 Equipment minimum elfitlency Provide equipment schedules or complete MECH-SUM tables with type. capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment M 1 C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; rote except C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limas per Table C403.2.10.1(1) C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1f12 to 1 hp ere ECM type or meet minimum efficiency req. C403.2.3 Maximum air cooled chillerIndicate capty air-cooled chiller capacity does not exceed air-cooled chiller limit C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non standard operetlon i conditions C403.2.12.1.2 Centrifugal fan cooling Dowers Large capacity cooling towers with centrifugal rants) meet efficiency requirements for axial fan open cirail cooling towers C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss Yes C403.23.3 Packaged electric heatinokgolinxl equipment List equipment required to be heat pumps on schedule M 1 C403.2.3A Humidification Indicate method of humiddication (note requirements lotsystems with economizer) NVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems M2 Yes C403.2.4.1.1 heat Heat WrnD sµoplementary Indicate staged heating (compression/supplemental) & outdoor lock -out temp M 1 Yes C403.2.4.2 Selport overlap (deadband) Indicate 5'F deadband minimum for systems controlling both heating & cooling M 1 Yes C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override M1 C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions Yes C402.4.5.2 & C403.2.4.4 Dam D era Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions M2 C403.2.11 Heating outside a building indicate radiant heat system end occupancy controls C403.2.4.5 Snow malt systems Indicate shut-off controls based on outdoor conditions C403.2.4.6 Combustion heating equipment Indicate modNati np or staged control C403.2.4.7 Group R sYslOms 1 tdtelfmael Indicate method for guest room automatic setback & set-up of 5'F minimum C403.2.41319 Group R2/R3 dwelling unit systems kxficate 5-2 programmable thermostats in primary spaces with minimum of two setback periods: note excepions taken C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV C403.2.5.2 Occupancy senses indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partiatly C403.2.5.3 Endosed loading dock/parking garage verdilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method C403.2.5.4.1 Kitchen exhaust hoods indicate kitchen hoods requiring make-up air: indicate make-up air source and conditioning method C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency: or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) C403 2 6 1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency, note exceptions C403.2.6.2 Energy recovery - condensate systems Indicate on -site steam heating systems requiring energy recovery C4403.2.6.3 Energy recovery - cardenser systems Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 MECH-CHK Commercial, Group RI, and > 3 story R2 and R3 Rs*ed June 2013 2012 Washington State Energy Code Compliance Forms for Project Address 100% PURE, WESTFELD SOUTHCENTER !Date 4/1/2014 The following WSEC. NO information is necessary to check a mechanical permd application for commercial provision compliance with the 2012 E: Define print area In Excel prior to printing M ECH.CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued C403.2.12 Variable lbw control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) C403.2.12.1 Variable flow control - cooling towers Indicate cooling tower fans requiring variabb flow control and method C403.2. t2.2 Large volume tan systems Indicate fan systems requiring airflow reduction based on heating end cooling demand; or exception taken C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and Indicate capability fa trendiro and demand response sdooint adiustment Ducting Systems Yes C403.2.7.18 C403.2.7.3 Oust tonatru<lion Indicate all ductwork constructed and sealed per MC, C402 leakage reauirementa and BC vapor retarder requirements M 1 Yes C403.2.7.3.1 ; Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M2 C403.27.3 3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed Yes C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on duchvak M 1 Piping Systems C403.2.8 Piping insulation Indicate R•value of insulation on piping C403.2.8.1 Piping er sufatian exposed to weatSIMPLE Indicate method of protection from damage/degradation on SYSTEMS Qualifying Systems C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling C403.3 Quallyirg 2-P/Pe heating systems Verify 2-pipe heating -only system does not exceed capacity limits C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple Sys em Economizers Yes C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip ached. M 1 C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) C403.1.1.2 Integrated air ecanornizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(e) COMPLEX SYSTEMS Complex System Economizers C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip ached. C4IX3.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not Increase building heating energy usage during normal operation C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water ecoro systems Moved Water economizer capacity Indicate water acorn capable ml 100% cooing capacity a150'F db/45'F wb OSA C403 4 1 2 Water economizer maximum pressure drop Indicate precooting coils and heal exchangers do not exceed pressure drop limit C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to camplywth exception(s) a Mechanical Permit Plans Checklist - Page 3 of 3 MECH-CHK RSNeae Jur* 2013 2012 Washington State Energy Code Cannpaance Font for Commercial, Group Rt. and> 3 slaty R2 and R3 Project Address 100% PURE, WESTFIELD SOUTHCENTER Ike 4/1/2014 The following WSEC. NO information is necessary to check a mechanical permit application for commercial provision comptianee with the 2012 E: Define print area in Excel prlor to printing MECH-CHK pages. Applicabttily (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements C403.4.2 & C403.2.12 Variable now control - fans Indicate fans requiring variable flaw Control and method C403 4.21 VAV fen static pressure SWUM Indicate sensor locations on plans; include at least one sensor per major dud branch C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoi t based on zone requiring most pressure ` C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served, note exceptions taken C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to toads C403 4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system Capacity > 300 tolls C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method C403.4.3 Large capacity baler systems Indicate multi -stage or modulating burner for single boilers > 500,000 btuh C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple balers C403.4.3.5 Chiller 1 boiler pent pump isolation indicate capability to automatically reduce overall plat flow end shut-off flow Through chillers & balers when not in use C403.4.2 & C403.4.3.6 Variable flaw control - pumps Indicate pumps requiring variable flow control & method C403.2.12.1 & C403.4.4 Variable lbw Coning - cooling towers Indicate cooling tower fans requiring variable flow control and method C403.4.3.4 Hydronic system part bad controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flaw by z 50% for systems > 300,000 C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min 20'F water supply temp deedband between heal rejection and heat addition modes C400.4.3.3 Water loop heat pimp - heat rejection Provide heal exchanger that separates coding tower and heat pump loop in Climate Zone 5 C403.4.3.3.3 Water loop heat pump - isolation indicate 2-way isolation valve on coa each heat pump and variable flow control f systems with total pump power > 10 he C403.4.6 ecovery Cr water heatIndicate system provided to pm -heat service water and efficiency C403.5 Cooler / freezer - anti -sweat heaters IndicateWs/ & control method for walk-in cooterlheezer door anti -sweat heaters C403.518 Coder / freeze - evaporator and condenser fans Indicate motor type for evaporator and condenser fens < 1 hp SERVICE WATER HEATING Service Water Systems Yes C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity. efficiency, test standard for other efficiency source) P1 C404.3 Temperature controls Indicate temperature controls have required selpoint capability C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply& discharge C404.5 kuulation under water healer Indicate R-10 insulation under tank C404.6 Service wale piping insulation kdtcate R-value of insulation on piping; note exceptions taken C404.718 Circulation systems and heat trace shut-off Indicate shutoff capability based on occupancy and periods of limited demand •meters C404.9 Group R-2 service hot water Indicate method of usage metering for dwell. urns served by central HW svatem Pools & In -Ground Permanently Installed Spas C404.10.1 Pod heating equip min. efficiencycapaciy, Provide equipment schedule or complete MECH-SUM table with type, efficiency, test standard (or other efl. source); heat ptsnp heaters z 4 COP C404.10.1 12 Pod heater on 1 off controlsIndicate automatic Darecontrol based on scheduling & accessible on/off switch on heater that operates independent of thermostat eettirw: or exception C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to> 90'F C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use • Interior Lighting Summary LTG -SUM 2012 Washington Stale Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Compliance forms do not require a password to use. Instructional and calculating CetlS are wale-•� protected. Project Address 100% PURE Date 4/1/2014 1395 SOUTHCENTER MALL, SPACE#356 For Building rtt Y FILE SEATTLE, WA. 98188 Applicant Name: TECTA AND ASSOCIATES Appticent Address: 271419TH ST. SAN FRANCISCO CA. 94110 AAM01%* Applicant Phone: 415 362 5857 Project Description ii New Building III Addition El Alteration El Plans Included Lighting Compliance Path ® Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance Method Selection required to enable LPA forms 0 Building Area Method ® Space -By -Space Method Interior Lighting System Description Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) • Addition area or Change of Space Use area complies with NI applicable provisions as stand atone project is combined with existing building lighting systems to demonstrate compliance with all applicable C101.4.3 Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting C405.2 and commissioning of lighting controls per C405.13. Q Addition area provisions per Provide Building allowed and controls per Alterations, Renovations and Repairs (C101.4.3.1) 0 60% or more of luminaires in space replaced Area Method (LTG4NT--BLD) or Space -By -Space Method (LTG-iNT-SPACE) Compliance Form. Document maximum within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. Provide Building allowed wattage Proposed Wattage of luminaires in space replaced Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. retrofit space in cell provided in the Maximum Allowed Wattage table Document Proposed Wattage table. Document existing total wattage proposed (including existing) lighting III Less than 60% Provide a separate within the lighting wattage in the RE+ t N Lamp and/or • ballast replacement within existing luminaires only - existing total interior building wattage not increased YI�• CaDE CO El New wiring installed to serve added factures and/or fixtures relocated to new circuit a PPF manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2. 3), specificc controls (C405.2.3), and commissioning of lighting controls per C405.13 APR Provide applicable application Q New or moved Provide all controls per lighting panel t ' applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commi forting of lighting C405.13. ^ �/ .i - luminaires unchanged or moved only !s vl'+ Y1 applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. BUILDING 111 Space is reconfigured Provide ell No changes are being made to the interior lighting and space use not changed. CORRECJION b t4-OOloO IED FOR IAPLIANCE OVED 1 2014 ukwila DIVISION RECEIVED CiTY OF TUKWILA APR 0 3 2014 PERMIT CENTER Interior Lighting Summary - Space -By -Space LTG-INT-SPACE 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 100% PURE Date 4/1/2014 Lighting Alterations, Renovations & Building Additions O Less than 60% 0 60% or more O Stand alone 0 Addition fixtures replaced fixtures replaced bldg. addition combined w/exist Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. 1f less than 60% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. For Building Department Use Maximum Allowed Lighting Wattage Location (plan #, room #) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) E3/#001 Sales area 1 . 68 694 1166 E3/#003 Restroom 0 , 98 64 63 E3/#002 Storage 0.63 80 50 4 i s . - 1 AA'-.""`�' i..t y,3' 1. } {{Q, F; . �I t ! > 11e x f s 79 < roii 1 i i t i s , t ;,-4Y r``,a.' + f'c 880 Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Proposed Lighting Wattage Total Area Allowed Watts 838 2159 Location (plan #, room #) Fixture Description*** Number of Fixtures Watts/ Fixture Watts Proposed E3/#001 (2)20W T4 RECESSED DN.LT.MULTI-DIRECTIONAL 22 E3/#001 (1)32W CFL DN.LT. 2 33 66 E3/#003 2X4 (3)32W F32T8 LT. FIXTURE 1 85 85 E3/#001 (2)20W T4 RECESSED DN.LT.MULTI-DIRECTIONAL 20 40 800 i1000.. ! 44004M.104 a S .. : , .. ?' r 880 Total Proposed Watts may not exceed Total Allowed Watts for interior Lighting "' include existing to remain lighting fixtures end exempt fighting equipment per notes below Total Proposed Watt 1831 Notes: 1. include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Waits/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5. 1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track fighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description 6. If #NA appears in Retail Display cells, information on LTG-INT-DISPLAY is incomplete. Interior Lighting Power Allowance COMPLIES Interior Display Lighting - Space -by -Space LTG-INT-DISPLAY 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address 180%PURE Date 4/1/2014 1395 SOUTHCENTER MALL, SPACE#356 For Building Department Use SEATTLE, WA. 98188 Applicant Name: TECTA AND ASSOCIATES Maximum Allowed Display Lighting Wattage Location (plan #, room #) Retail Display Area Type* Allowed Watts per ft2** Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) E3l#001 Retail 3: Furniture, clothing, cosmetics, artwork 1, 40 674 94 4 ' Only retail sales areas that meet the requirements defined in Table C405.5.2(2) footnote A may be entered here. Select retail sales areas torn drop down menu. • Wattages per Table C405.5.2(2) footnote A. ++ Display fight allowance per footnote A calculation. Proposed Display Lighting Wattage Total Area Area Watts 674 944 Display Lighting Base Allowance ++ Total Display Allowance 500 1444 Only separately controlled display fixtures independent of General area lrohtinq per Table C405.5.2(2) footnote A may be entered here. Display Area Location (plan #, room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Retall 3 E341001 (2020W, (2)HEADS MULTI -DIRECTION 22 40 880 * Select retail sales display area from drop down menu. DISPLAY WATTAGE ALLOWED - AS PROPOSED Proposed Display Lighting Totals Total Proposed Watts 880 Retail 1 Retail 2 Retail 3 Retail 4 880 Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the Torture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed WattsiFixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track fighting, fist the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current Limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List aV display fixtures. Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK 2012 Washington Stale Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all RI Revised Jan 2014 Project Address 100%PURE Date 4/1/2014 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS (Section C405 2) Yea C405.2.1.1 C405.2.1.2 Manual interior lighting controls Indicate on plans the manual control type & tocations served; Indicate of plans the 50% lighting load reduction method provided or identify exception taken E-3.0 Yen C405.2.2.1 Automatic time switch controls and override switching Indicate lighting system automatic shut-off capability - identity lighting zone areas served on plans; E•3.0 Indicate locations of override switches on plans and the areas served, include area sq. ft.; E•3.0 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) E-3.0 Ya,a C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E-3.0 C405.2.2.3 Daylight zones - Vertical fenestration and skylights Indicate vertical fenestration primary and secondary daylight zone areas on plans. include sq. ft.; E-3.0 Indicate skylight daylight zone areas on plans, include sq. ft. NA C405.2.2.3.2 Daylight zone controls Indicate on plans the locations served by daylight zone controls; E-3.0 Indicate In plans the lighting load reduction (dimming) method - stepped or continuous dimming E-3.0 Yea C405.2.3 Specific application lighting controls - General Indicate on plans the locations served by specific application lighting controls E•3.0 Yes C405.2.3 - Items 1 i2 Display and accent lighting Indicate lighting control method for display and accent lighting, and display case lighting; hdicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space E•3.0 C405.2.3 - Item 3 Hotel/motel guest rooms Provide a lighting control device at each guest room entry for all permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic Yes C405.2.3 • Item 4 Supplemental task lighting Provide automatic shut-off vacancy controls fa supplemental task lighting, including under -shelf or under -cabinet lighting E-3.0 Yea C405.2.3 - Item 5 Lighting for non - visual applications Identify eligible non -visual applications and method of lighting control; Indicate these fixtures are controlled independenUy from both general area lighting and other lighting applications within the same space E•3,0 C405.2.3 • Item 6 Lighting equipment for sale or demonstration Indicate lighting control method for lighting equipment for sale or demonstration; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Yoe C405.2.3 - Item 7 Means of egress lighting Kegress lighting power density is greater than 0.05W/11, indicate method of automatic shut-off during unoccupied �s' E-3.0 Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination C405.10 C405.11 Cooler and freezer lighting Provide vacancy device or timer to turn off fixtures within 15 minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt C405.2.4 Exterior lighting controls Indicate on exterior lighting plans the automatic lighting control method and locations served C405.8.1 Exterior building grounds lighting controls Provide motion sensor controls for building grounds fixtures rated at greater than 100 watts with tamp efficacy less than 60 lumens, or identify exception taken NA C408.3 Lighting system functional testing Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response; Identify In construction documents the party responsible for functional testing of automatic fighting controls INTERIOR LIGHTING POWER & EFFICACY (Sections C405.5, C405.10, C405.11) Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and ail R1 Revised Jan 2014 Project Address 100%PURE Date 4/1/2014 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes yes C405.5.1 C405.5.1.1 C405.5.1.2 C405.5.1.3 C405.5.1.4 Total connected interior lighting power g g Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; Identify lighting equipment eligible for exemption In fixture schedule and in compliance forms; E-3.0 Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently Yee C405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture schedule (maximum 5 watts per fixture' E-3.0 C405.10 C405.11 Cooler and freezer lighting For lighting In walk-in coolers and freezers, and refrigerated warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule Lighting Power Calculation - Indicate compliance path taken Yes C405.5.2 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans E-3.0 Yee C405.5.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas as applicable E-3.0 EXTERIOR LIGHTING POWER & EFFICACY (Section C405.6) C405.6.2 Total connected exterior lighting p Provide fixture schedule with fixture types. lamps, ballasts, and rated watts per fudure; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by theAHJ C405.8.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts, provide rated lamp efficacy (in lumens per watt) in fixture schedule C405.6.2 Exterior lightingComplete p calculations required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency C405.9 Transformers Provide distribution transformer schedule on electrical plans with transformer size and efficiency If "no" is selected for any question, provide explanation: J City of Tukwila Department of Community Development March 21, 2014 ANDRE WAINWRIGHT 2747 19 ST SAN FRANCISCO, CA 94110 RE: Correction Letter # 2 DEVELOPMENT Permit Application Number D14-0060 100% PURITY COSMETICS - 1395 SOUTHCENTER MALL Dear ANDRE WAINWRIGHT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • 1. Previous review memo request was to "Provide a lighting budget compliance form for 2012 Washington State Nonresidential Energy Code. 2012 NREC Compliance Forms for Lighting is available online at: http://www.neec.net/energy-codes, (scroll down to center of page)." The energy code compliance provided by COM check software is not verifiable to be in compliance with or have reference to the Washington State Energy code. Please provide the completed WSEC form as requested. The forms may be provided on 8 y2 x 11 letter size sheets, available on the NEEC website rather than submitting a full size plan sheet. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D14-0060 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 associates PURE SOUTHCENTER PLAN CHECK COMMENTS #1 March 11, 2014 Application #: D14-0060 Address: 1395 Southcenter Mall Plan Checker: Allen Johannessen Cc: Randy Everman Architectural Comment Responses: 1. See Sheet T-1.0 the occupant load factor has been changed from 100 to 30 2. See Sheet A-6.3 Enlarged Restroom, The vertical grab bar has been added Electrical Comment Responses: 1. See Sheet LG-1 CORRECTION bt/4--•oow RECEIVED CITY OF TUKWILA MAR 1 8 2014 PERMIT CENTER 2747 t9th Street, San Francisco, CA 94110 . tel. 415.362,5857 fax 415 362.5044 . www.tccta.corr architecture ) interior design y branding CITY OF TUKWILA PERMIT CENTER MEMORANDUM To: Andre Wainwright with Tecta Associates From: City of Tukwila, Permit Center Re: Applications by Mail/FedEx Date: 03/13/14 The City of Tukwila Permit Center does not accept applications and/or resubmittals by mail, fax, UPS or FedEx. Consequently you will find your plans enclosed. There was not a Revision Submittal form included. I have included another Revision Submittal form and a copy of the Correction Letter that were previously mailed to you. Please submit your application in person to the Permit Center between the hours of 7:30 AM to 4:30 PM Monday through Friday. No appointment is necessary. We are located at 6300 Southcenter Boulevard, Ste 100, Tukwila, WA 98188. Sincerely, Bill Rambo City of Tukwila Department of Community Development March 04, 2014 ANDRE WAINWRIGHT 2747 19th ST SAN FRANCISCO, CA 94110 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D14-0060 100% PURITY COSMETICS - 1395 SOUTHCENTER MALL Dear ANDRE WAINWRIGHT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (BUILDING REVIEW NOTES) 1. The occupant factor square foot per person indicated on the front sheet shows 100. Since this is an M occupancy the occupant factor is 30. Other business areas would be calculated at the factor of 100. Revise the Occupancy Load calculation to meet current code. In addition include 2009 ANSI Barrier free codes in the code section. 2. On sheet A-6.3 show an 18" vertical grab bar with the required dimensions for the accessible toilet. (2009 ANSI 604.5.1) 3. Provide a lighting budget compliance form for 2012 Washington State Nonresidential Energy Code. 2012 NREC Compliance Forms for Lighting is available online at: http://www.neec.net/energy-codes, (scroll down to center of page). Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D14-0060 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0060 DATE: 04/03/14 PROJECT NAME: 100% PURITY COSMETICS SITE ADDRESS: 1395 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 2 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 4-5 Avg_ M -4- ( 41 Building Division II Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/08/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 05/06/14 tEr Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0060 DATE: 03/18/14 PROJECT NAME: 100% PURE COSMETICS SITE ADDRESS: 1395 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: C Suildm Dire 1 1 ivision g Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 03/20/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 04/17/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only t t� CORRECTION LETTER MAILED: 1631 �` Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0060 DATE: 02/20/14 PROJECT NAME: 100% PURE COSMETICS SITE ADDRESS: 1395 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Div sion111 Fire Prevention Structural 4104k- '''/"1""( %//k AYA— (11 • Planning Division II Permit Coordinator • PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 02/25/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 03/25/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: -13— "1_t Departments issued corrections: Bldg J Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hup://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ail02/"r" Plan Check/Permit Number: D 14-0060 ❑ Response to Incomplete Letter # • Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 100% Purity Cosmetics RECEIVED CITY OF TUKWILA APR 0 3 2014 PERMIT CENTER Project Address: //��eA1395Southcenter Mall Contact Person: dAhN licilt%lr-llif0 Phone Number:. ('4A)3- 58.7 Summary of Revision: �,/0/ /t Meni5 *4 rO $v6df9.. ,Q:'rz/ Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on Li— \applications\forms-applications on linc\revision submittal Created: 8-13-2004 Revised: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan ChecWPermit Number: D 14-0060 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 100% Pure Cosmetics Project Address: 1395 Southcenter Mall Contact Person: % t /At4l'4/ 7 Phone Number: (¢i 5) a - 057 X /12? Summary of Revision: %- / D = /;=t/�./ OLe-4/j.1i -d .�o /�-4•3= "t y .277, 4,Toiz' /pv �!��"" y_� Pere L-wiy--"q' RIMED env or '1ElIutr Canal Sheet Number(s): 7-70/ 142"4•3 L�-J "Cloud" or highlight all areas of revision including date of rev Received at the City of Tukwila l PermitCenterCenter by: -Entered�`' in TRAKiT on 9"--1 \applications\forms-applications on Iine\revision submittal Created: 8-13-2004 Revised: TASHCON CORP Page 1 of 2 C:oWashington State Department of Labor & Industries TASHCON CORP Owner or tradesperson MAHON, HAROLD JOSEPH Principals MAHON, HAROLD JOSEPH, PRESIDENT Doing business as TASHCON CORP WA UBI No. 603 051 851 710 E MCGLINCY LN #112 CAMPBELL, CA95008-5081 408-540-7880 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. TASHCC*902PQ Effective — expiration 05/16/2011— 05/16/2015 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 723375 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 10/15/2010 10/04/2010 Insurance Mt Hawley Ins Co $1,000,000.00 Policy no. MGL0180643 Received by L&I Effective date 04/29/2014 01/15/2014 Expiration date 04/15/2015 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603051851 &LIC=TASHCC*902PQ&SAW= 04/30/2014 VICINITY MAP 1. THE A.I.A. DOCUMENT, A-201, LATEST EDITION "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" SHALL PREVAIL. 2. SCOPE: A. PROVIDE ALL MATERIAL, EQUIPMENT AND LABOR TO COMPLETE THE WORK AS INDICATED ON THE DRAWINGS. B. IN GENERAL THE WORK INCLUDES BUT IS NOT LIMITED TO THE COMPLETE INTERIOR ALTERATION, INCLUDING NEW WALLS, CEILING, FLOORING, LIGHT FIXTURES, AND CASEWORK. THE CONTRACTOR SHALL SUBMIT. PROPOSED CONSTRUCTION SCHEDULE 1. DEMOLISH EXISTING STRUCTURES AS SHOWN OR NOTED. 2. ALTERATION TO CONSTRUCTION, ELECTRICAL, PLUMBING AND HVAC 3. PATCH TO MATCH FINISHES AFFECTED BY THE NEW CONSTRUCTION. 4. INSTALL ALL NEW WORK SHOWN ON DRAWINGS AND AS REQUIRED. 3. CONTRACTOR SHALL VISIT THE SITE, CAREFULLY EXAMINE THE AREAS AFFECTED BY THE WORK AND FAMILIARIZE THEMSELVES OF THE CONDITIONS AND SHALL REPORT TO ARCHITECT ANY DISCREPANCIES OR COMMISSIONS WHICH WOULD INTERFERE WITH SATISFACTORY COMPLETION OF THE WORK PRIOR TO SUBMITTING BIDS. 4. THE CONTRACTOR SHALL MAKE SURE THAT ALL TRADES WORK CONFORMS TO THE LATEST FEDERAL, STATE AND CITY CODES AND ORDINANCES. 5. THE CONTRACTOR SHALL OBTAIN PERMITS BEFORE STARTING WORK AND OBTAIN APPROVALS OF ALL REGULATORY AGENCIES UPON COMPLETION. 6. WHEN "APPROVED EQUAL", "EQUAL TO," OR OTHER GENERAL QUALIFYING TERMS ARE USED, IT SHALL BE BASED UPON THE REVIEW AND APPROVAL BY THE ARCHITECT PRIOR TO ANY PURCHASE OR INSTALLATION. 7. THE CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS FOR APPROVAL TO THE ARCHITECT AND OWNER PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR TO SUBMIT CUTS, SAMPLE AND FINISHES FOR WRITTEN APPROVAL PRIOR TO ORDERING OR FABRICATION. ALL. SUBMITTALS SHALL BE IN TRIPLICATE TO THE ARCHITECT. CONTRACTOR SHALL REVIEW SUBMISSIONS PRIOR TO SUBMITTAL AND SHALL NOTE HIS APPROVAL ON SAME. THE CONTRACTOR SHALL PROVIDE THE ARCHITECT A MINIMUM OF TEN (10) WORKING DAYS TURNAROUND TO REVIEW SHOP DRAWINGS. 8. THE WORD "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL ALL MATERIALS NECESSARY TO COMPLETE WORK IN ACCORDANCE WITH ACCEPTED CONSTRUCTION STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. 9. ALL ITEMS SPECIFIED ARE TO ESTABLISH QUALITY OF WORK. PRODUCTS OF OTHER MANUFACTURERS EQUAL IN DESIGN, COLOR AND QUALITY MAY BE SUBSTITUTED IF APPROVED BY THE ARCHITECT AS MEETING ESTABLISHED DESIGN AND FUNCTION CRITERIA. ANY PROPOSED SUBSTITUTIONS MUST BE QUALIFIED AT BID SUBMISSION. 10. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE BEST ACCEPTED TRADE PRACTICES AND AS PER MANUFACTURERS RECOMMENDATIONS. 11. A COPY OF THE LATEST SET OF CONSTRUCTION DRAWINGS, SPECIFICATIONS AND SHOP DRAWINGS SHALL BE KEPT AT THE JOB SITE FOR REVIEW BY THE ARCHITECT. THESE DRAWINGS SHALL BE UPDATED WITH THE LATEST REVISIONS. 12. THE CONTRACTOR SHALL PREPARE AND UPDATE CONSTRUCTION SCHEDULE. COMPLETION DATE MAY NOT BE EXTENDED WITHOUT WRITTEN NOTICE. 13. THE WORK IS NEXT TO AN AREA THAT MUST CONTINUE IN OPERATION DURING THE PROGRESS OF THE WORK, THE CONTRACTOR IS TO HAVE MINIMUM INTERFERENCE WITH OPERATION WESTFIELD SOUTHCENTER 1395 SOUTHCENTER MALL SPACE #356 SEATTLE, WA 98188 14. ALL ELECTRICAL WORK TO BE IN FULL COMPLIANCE W/ STATE & LOCAL CODES. 15. CONTRACTOR SHALL MAINTAIN FREE AND UNOBSTRUCTED ACCESS FROM ALL FLOOR AND ADJACENT SPACES TO OUTSIDE OF THE BUILDING AT ALL TIMES DURING CONSTRUCTION. 16. CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT AS SHOWN UNLESS OTHERWISE NOTED BY ARCHITECT. ALL MATERIAL SHALL BE NEW AND OF THE BEST QUALITY. 17. CONTRACTOR SHALL INCLUDE ALL CUTTING, DRILLING AND PATCHING REQUIRED TO PERMIT THE INSTALLATION OF HIS WORK AND HIS SUB -CONTRACTORS. 18. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF WORK OF ALL SUB -CONTRACTORS. 19. ALL MATERIAL AND. EQUIPMENT SHALL MEET APPLICABLE STANDARDS AS PUBLISHED BY ANSI AND NEMA AND SHALL BE LISTED BY U.L., WHERE REQUIRED, MEA NUMBERS MUST BE PROVIDED. 20. ANY DAMAGES TO EXISTING PARTITIONS, FLOORS, CEILINGS OR ANY PART OF THE BUILDING OR EQUIPMENT CAUSED BY THE WORK OF THE CONTRACTOR SHALL BE MADE GOOD AT NO ADDITIONAL EXPENSE TO THE OWNER. 21. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE FROM THE JOB SITE AND BROOM CLEAN DAILY. - COORDINATE WITH STORE OPERATIONS. CONTRACTOR TO USE THEIR OWN DUMPSTERS FOR DEBRIS REMOVAL. 22. THE CONTRACTOR IS TO CONTROL CLEANING TO PREVENT DIRT OR DUST FROM LEAVING THE JOB SITE AND INFILTRATING AREAS NOT INVOLVED IN THE PROJECT. 23. WHEN REMOVING AN EXISTING OUTLET, CABLES ARE TO BE REMOVED FROM ORIGINATING POINT AND A COVER PLATE TO BE INSTALLED AT THE WALL. IN CASE OF ELECTRIC OUTLETS, WIRES ARE TO BE REMOVED TO THE JUNCTION BOX, AND CAPPED. COVER PLATE TO BE INSTALLED AT WALL. REMOVE ALL ABANDONED CONDUIT. 24. ALL NEW, MODIFIED OR EXISTING OUTLETS ARE TO BE CIRCUITED TO CONFORM TO APPLICABLE ELECTRICAL BUILDING CODES. 25. G.G. RESPONSIBLE FOR REVIEWING LANDLORD CONSTRUCTION AND IS RESPONSIBLE FOR ALL ATTACHMENTS AND COMPLETION OF WORK TO PROVIDE A WORKING ASSEMBLY. 26. G.C. SHALL FULLY COMPLY WITH MACY'S REQUIREMENTS FOR METHODS OF CONSTRUCTION, HOURS OF WORK, NUISANCE CONTROL, QUALITY OF CONSTRUCTION AND MATERIALS ALLOWED, DELIVERY AND STORAGE OF MATERIALS, CLEANNESS AND ANY OTHER STANDARD CONSTRUCTION RESTRICTION. G.C. WILL INFORM SUBCONTRACTORS OF REQUIREMENTS BEFORE SUBMITTAL OF BIDS. 27. ALL POTENTIALLY NOISY OR DUSTY WORK TO BE DONE ON OFF STORE HOURS. 28. SPRINKLER WORK IS DESIGN -BUILD. 29. PROVIDE SAMPLES FOR ALL PAINT AND STAINS, CASEWORK FINISHES. PAINTING INCLUDES ALL COATINGS AND SEALANTS 30. PROVIDE SHOP DRAWINGS/SUBMITALS FOR CASEWORK, AUTOMATIC OPENING DOOR, ALPOLIC APPLICATION, DISPLAY SHELVING, GLASS DISPLAY AND ALOPOLIC WORK. PROVIDE SUBMITTALS FOR ALL ALL ITEMS NOT CALLED OUT OR SPECIFIED IN THESE DOCUMENTS BUT REQUIRED TO BE COMPLETED 31. ALL EQUIPMENTS PROVIDED SHALL HAVE A MINIMUM OF ONE (1) YEAR WARRANTY FROM DATE OF ACCEPTANCE OF WORK. 32. THE CONTRACTOR SHALL GUARANTEE THAT ALL WORK OF THIS CONTRACT IS FREE FROM ALL DEFECTS, AND IS AS SPECIFIED. SHOULD ANY DEFECTS, WHICH CANNOT BE PROVEN TO HAVE BEEN CAUSED BY IMPROPER USE, DEVELOP WITHIN THE PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE OF WORK, SUCH DEFECTS SHALL BE MADE GOOD BY THE CONTRACTOR, WITHOUT COST TO THE OWNER. LIST OF DRAWINGS T-1.0 COVER SHEET D-1.0 DEMOLITION PLAN & DEMO REFLECTED CEILING PLAN A-1.0 CONSTRUCTION PLAN & REFLECTED CEILING PLAN A-2.0 FLOOR FINISH PLAN & FURNITURE PLAN A-6.0 EXISTING AND NEW STOREFRONT SECTIONS A-6.1 PROPOSED ELEVATIONS A-6.2 PROPOSED INTERIOR ELEVATIONS A-6.3 ENLARGED RESTROOM PLANS & ELEVATIONS A-7.0 SCHEDULES A-8.0 DETAILS A-8.1 DETAILS A-8.2 DETAILS SCOPE OF WORK SCOPE OF WORK IS TO REMODEL EXISTING SPACE TO NEW RETAIL LOCATION FOR 100% PURE COSMETICS. SCOPE OF WORK INCLUDES STOREFRONT AND STORE INTERIORS COMPLETE, PER LL CRITERIA, LOCAL CODES, AND CONSTRUCTION DOCUMENTS, LIST OF SYMBOLS SECTIONS OR ELEVATIONS DETAIL DETAIL 'ENLARGEMENT i LETTER USED FOR BUILDING SECTIONS OR FOR ELEVATIONS DRAWING NUMBER WHERE SECTION OR ELEVATION APPEARS DETAIL,ELEVATION AND/OR SECTION IDENTIFICATION INTERIOR ELEVATIONS NUMBER USED FOR DETAIL DRAWING NUMBER WHERE DETAIL APPEARS NUMBER OR DETAIL DRAWING NUMBER WHERE DETAIL APPEARS AREA BEING ENLARGED DEFINED BY DOTTED LINE DETAIL LABEL WALL FLASHING 2 SCALE:1/2"=1'-0" ELEVATION NUMBERS zr_____ j DRAWING NUMBER WHERE ELEVATION APPEAR 1421 1 A ARCHITECT ROOM NUMBER DOOR NUMBER REVISION NUMBER PARTITION TYPE EL. 452' 2'2"- FINISHED ELEVATION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal end may include additional plan review fees, PROJECT DATA ADDRESS: WESTFIELD SOUTHCENTER 1395 SOUTHCENTER MALL SPACE #356 SEATTLE, WA 98188 CONSTRUCTION TYPE: II-B FULLY SPRINKLERED STORIES: 2 OCCUPANC OCCUPANCY LOAD CALCULATION SALES AREA - 687 SF/OCC - 30 SF/OCC = 22.9 NON SALES - 280SF/OCC - 200 SF/OCC = 1.4 TOILET ACCESSORY TOTAL OCCUPANT LOAD = 8.2 EXITS REQUIRED: 1 CODES 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL MECHANICAL C 2012 UNIFORM PLUMBING CODE 2011 NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL FIRE CODE 2012 WASHINGTON STATE ENERGY CO A.F.F. AC. PL. AC. T. NC AL BL. BR. C.L. CEM. CL. CLG. COL. CONC. CONST. CONT. D.F. D.O. DIM. DN. DTL. EA. EL. ELEC. ELEV. ENCL. EXIST. E.C. F.A.I. F.D. F.F. FIN. FL. F.P.S.C. F.O. F.R. F.S. GL. GYP. BD. G.C. H.M. H.V.A.C. H.CLG. HGT. PARTIAL SITE MAP EP®RATE-PERMIT, HEQU;IRED FOIE E sctric€i iurrlb' Rides 1212, C:ty of Tukwi B l' .NG DIVISION, DE ABBREVIATIONS ABOVE FINISH FLOOR ACOUSTIC PLASTER ACOUSTIC TILE AIR CONDITIONING AT ALUMINUM BLOCK BRICK CENTER LINE CEMENT CLOSET CEILING COLUMN .CONCRETE CONSTRUCTION CONTINUOUS DRINKING FOUNTAIN DOOR OPENING DIMENSION DOWN DETAIL EACH ELEVATION ELECTRIC ELEVATOR ENCLOSURE EXISTING ELECTRICAL CONTRACTOR FRESH AIR INTAKE FLOOR DRAIN FINISHED FLOOR FINISH FLOOR FIREPROOF SELF CLOSING FINISHED OPENING FIRE RATED FULL SIZE GLASS GYPSUM BOARD GENERAL CONTRACTOR HOLLOW METAL HEATING VENT & AIR CONDITIONING HUNG CEILING HEIGHT MEP ENGINEER INS. J.B. J.C. MAS. MFG. M.C. N.I.C. N.T.S. O.C. P. PART. PL. R.A. REF. REG. RES.T. RM. R.O. S.A. S.C. S.C.W.D. S.P. S.S. STD. STOR. ST. T. TEL. T.O.S. T.O. TERR. T.O.W. TYP. UNFIN. U.O.N. VEST. V.I.F. V.T. INSULATION JUNCTION BOX JANITORS CLOSET MASONRY MANUFACTURING OR MANUFACTURER MILLWORK CONTRACTOR NOT IN CONTRACT NOT TO SCALE ON CENTER POINT PARTITION PLASTER -PLATE • RETURN AIR REFER REGISTER RESILIENT TILE ROOM ROUGH OPENING SUPPLY AIR SELF CLOSING SOLID CORE WOOD DOOR STANDPIPE SERVICE SINK OR STAINLESS STEEL STANDARD STORAGE STEEL OR STREET OR STAIR TREAD OR TOILET TELEPHONE TOP OF SLAB TRIMMED OPENING TERRAZZO TOP OF WALL TYPICAL UNFINISHED UNLESS OTHERWISE NOTED VESTIBULE VERIFY IN FIELD VINYL TILE OWNER'S REP. TECTA ASSOCIATES 2747 - 19TH STREET SAN FRANCISCO, CA 94110 RANDY EVERMAN 1095 CHAPMAN STREET SAN JOSE, CA 95126 SITE LOCATION N.T.S RESPONSIBILITIES BY NOTE FURNISHED BY INSTALLED BY VENDOR CONTRACTOR CLIENT VENDOR CONTRACTOR CLIENT ITEMS DEMOLITION + PREPARATION • • CONCRETE/ REPAIR • INTERIOR DEMOLITION • SIGN POWER • STOREFRONT COMPLETE • • SIGNAGE • • FRAMING • • PLUMBING • • ELECTRICAL • • SHEETROCK • • CARPENTRY • • TILE • • BACKING/ SUPPORTS • • MILLWORK/ FIXTURES • • CARPENTRY • • LIGHTING • • HARDWOOD • • PAINT • • WALL GRAPHICS • • METALS • • GLASS • • CEILING TILE • • REPAIR TO (E) SURFACES • HVAC COMPLETE • • BATHROOM FIXTURES • • FIRE SPRINKLERS/ ALARM - 0 • DOORS • • SOUND WIRING/ SPEAKERS • • FURNITURE • • POS SYSTEM • • DATA • • WIFI • • NOTE 1-GC IS REQUIRED TO DO ALL WORK REQUIRED TO COMPLETE PROJECT AND PRODUCE WORKING EQUIPMENT, FIXTURES, LIGHTING AND ALL OTHER CODE REQUIREMENTS OF PROJECT. NOTE 2-FIRE SPRINKLER AND ALARM SYSTEM IS DESIGN BUILD BY GC AND IS A DEFERRED PERMIT. DESIGN UST BE REVIEWED AND APPROVED BY LL AND JURISDICTION. NOTE 3-ALL PENETRATIONS ARE TO BE MADE TO LL CRITERIA NOTE 4-MAINTAIN ALL FIRE RATINGS AND FIRE STOPS AS REQUIRED SIGNAGE UNDER SEPERATE PERMIT FIRE SPRINKLERS UNDER SEPERATE PERMIT FOR ANY MODIFICATIONS AND/OR ADDITIONS TO THE AUTOMATIC FIRE SPRINKLERS AND/OR FIRE ALARM SYSTEMS PER CITY OF TUKWILA, FIRE DEPARTMENT PERMITS. VFC SEC 901.3 FIVALopir Penult No. Plan review approval is subject to errors and ,���omissions. kpf ok:al of condocumentsdoesstructiof dnot authorize the v;o!ation of any adopted code or ordinance. Receipt of approved Field Copy and macreis acknowledged: BY :twic2©r 7 City Of'1"tol►l BUILDING DIVISION CORRECTION LTR#. REVIEWED FOR CODE COMPLIANCE APPROVED APR 11 2014 City ofTukvviia BUILDING DIVISION RECEIVED CITY OF TUKWILA t 14 MAR 1 8 2014 CENTER associctes • ARCHITECTURE • INTERIORS • PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 18 REGISTERED ARCHITECT HMAD MOHAZAB TE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 co ww F-- Z < w� U� o rM� J w V, O VJ w F.- w Q LU W U LL E w VJ w f0 v V 0) M NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF IECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT UNITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: DESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 •CD'S SUBMITTED TO LL, PERMIT VENDORS FOR APPROVAL 02/07/14 BUILDING DEPARTMENT 02/17/14 ASUBMITTAL PLAN CHECK COMMENTS BUILDING DEPT RESUBMITTAL 03/11/14 ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: COVER SHEET DRAWING NUMBER: T-1.O (415) 362-5857 PHONE (415) 362-5044 FAX CONTACT: AHMAD MOHAZAB AHMAD@TECTA.COM (408) 205-2565 CELL CONTACT: RANDY EVERMAN RANDYEVERMAN@GMAIL.COM 1 // 1 1 1 J 1 DEMOLITION FLOOR PLAN Scale: 1/4" = 1'-0" REVIEWED FOR CODApPE ROVED CE APR 1 1 2014. City of Tukwila BUILDING DIVISION NOTE: 1. DRYWALL BARRICADE INSTALLED BY GENERAL CONTRACTOR, INCLUDING GRAPHICS. 2. COORDINATE LOCATION OF BARRICADE WITH LANDLORD. 3. GRAPHICS SHALL BE APPROVED BY LOCAL MALL TEAM SYMBOL LEGEND u (E) PARTITION TO REMAIN (E) CONSTRUCTION TO BE DEMOLISHED (E) DOOR TO BE DEMOLISHED KEY NOTES 0 DEMO EXISTING WALLS 20 DEMO STOREFRONT GLASS & BASE 03 EXISTING ROLL -UP GRILLE TO REMAIN O DEMO (E) DOOR & FRAME O DEMO EXISTING CEILING AND ALL FIXTURES O DEMO EXISTIHNG A.C.T. CEILING AND ALL FIXTURES O DEMO EXISTING ELECTRICAL PANEL O DEMO EXISTING PLUMBING FIXTURES AND CAP ALL LINES O DEMO EXISTING MALL POP OUT SOFFIT, SEE SECTION A-6.0 10 DEMO EXISTING FLOORING MATERIAL THRU-OUT 11 EXISTING EXPANSION JOINT TO REMAIN 12 EXISTING COLUMN TO REMAIN 613) BARRICADE PER LANDLORD REQUIREMENTS bI'ootoo GENERAL NOTES 1. CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED TO, THE DEMOLITION AND REMOVAL OF WALLS, FLOORS, FLOOR FINISHES, CEILINGS, BUILT-IN COUNTERS, COUNTERS AND CABINETS, DISPLAY COUNTERS, BULKHEADS, DOORS, FIXTURES, PLUMBING, MECHANICAL AND ELECTRICAL ITEMS INCLUDING CONDUITS AND DUCTWORK AS SHOWN ON DRAWING OR AS REQUIRED FOR THE INSTALLATION OF THE NEW WORK FOR A COMPLETE JOB. 2. DO NOT REMOVE ANY STRUCTURAL WALLS (LOAD BEARING OR SHEAR WALLS) OR OTHER STRUCTURAL ELEMENTS. NOTIFY ARCHITECT IF ANY STRUCTURAL ELEMENTS ARE DISCOVERED AND NOTED TO BE REMOVED AND NOT NOTED AS STRUCTURAL ELEMENTS. 3. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT OF ANY CONCEALED OR UNKNOWN CONDITIONS. RECEIVED CITY OF TUKWILA FEB 2 :.Q 2014 PERMIT CENTER A fr gk, 1 1 ‘_ . . . . T ECTA 0 associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7318 REGISTERED ARCHITECT • AHMAD MOHAZAB STATE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 1.0 ft It ww Z Q ww UU) o =J.; N-- Q CD %1- 2 < ww Z I_' _1 U UJUQ LL = w iti%M, F--F u) U) w 0�^ u) LO 0) Cr) r NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE SHALL NOT BE DISPLAYED IN ANY MANNER EXCEPT BY WRITTEN AGREEMENT WITH TECTA TAKE PREFERENCE OVER SCALED DIMENSIONS AND SITE. TECTA ASSOCIATES IS TO OF ANY DISCREPANCIES' IN DIMENSIONS PRIOR WORK. THESE DRAV9NGS ARE INTENDED FOR DESIGN USE IN CONSTRUCTION UNLESS APPROVED AS THESE PLANS ARE COPYRIGHTED AND SUBJECT ARCHITECTURAL WORK" UNDER SEC. 102 OF AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL ACT OF 1990. THE PROTECTION INCLUDES BUT IS WELL AS THE ARRANGEMENT AND COMPOSITION OF NO. REVISIONS: PROPERTY OF TECTA OR USED ON ANY ASSOC. WRITTEN SHALL DE VERIFIED BE NOTIFIED TO THE COMMENCEMENT PURPOSES ONLY SUCH BY GOVERNING TO COPYRIGHT PROTECTION THE COPYRIGHT ACT, WORKS COPYRIGHT NOT UNITED TO THE SPACES AND ELEMENTS ASSCOC. AND OTHER WORK DIMENSIONS ON THE JOB IN WRITING OF ANY AND NOT FOR AUTHORITIES. AS AN 17 U.S.O. AS PROTECTION OVERALL FORM AS OF THE DESIGN. DATE: ADESIGN SUBMITTED FOR APPROVAL TO LL 01/15/14 ACD'S SUBMITTED TO VENDORS FOR APPROVAL LL, PERMIT 02/07/14 ABUILDING . DEPARTMENT SUBMITTAL 02/17/14 ISSUE DATE: SPACE PLAN DATE: . 12/19/13 DRAWING TITLE: DEMOLITION PLAN DRAWING NUMBER: C9) 20'-6" ti 1/2" NEW CLEAR 1/2" ALUM ANODIZED -7 4 REVEAL /4" 4, 002 102 y W J 0 2 103 HDCP RESTROOM 003 MOW reA I I L_ AL - 21II CLEAR B C D SALES AREA 001 A • LINE OF EXISTING STOREFRONT 100 8'-O" 20'-6" 2'-0' 0 ti L 3'-2" LINE OF NEW STOREFRONT PER MALL STANDARDS O G M CONSTRUCTION PLAN Scale: 1/4" = r. V. NEW CLEAR 1/2" f ANODIZED ALUM REVEAL 0 \ \ 1' \ \ CO 2 W a z 0 w LINE OF NEW ST 0 0 0 0 P 0 O o o 0 0 o 0 o eo % u r1 o ° O I\ o 0 0 o 0 o o 0 o o 0 0 Q� REFLECTED CEILING PLAN Scale: 1/4" = 1'-0" SYMBOL LEGEND (E) PARTITION TO REMAIN 3 5/8" 20GA MTL STUD FURRING W 5/8" TYPE 'X' GWB AT EXPOSED SIDES /,�i./%orie/e�o2, (N) FULL HIEGHT PARTITION 3%" 20 GA METAL ENDS @16" O.C. W/ %"TYPE 'X' GYP BOARD BOTH SIDES; FIRE CAULK AND TAPED METAL SIGN BOX/ROLL DOWN GRILLE. POST CLADDING CONSTRUCTION KEY NOTES 0 (N) ROLL DOWN GRILL 02 (N) ILLUMINATED SIGN BOX BY SIGN VENDOR. 03 LEASE LINE 0 (N) TELEPHONE BACKBOARD O (N) ELECTRICAL PANEL O(N) POST FOR ROLL -DOWN GRILLE RAIL SUPPORT 07 SINK - KOHLER KATHRYN #K-2297-G FAUCET - GROHE ALLURE #20191-000 O G.C. TO PROVIDE BACKING FOR WALL STANDARDS 9 RECESSED WALL STANDARDS BY VISPLAY SYSTEM, SEE SHEET A-6.2 10 (N) TEMPERED BUTT -JOINED GLASS -1/2" STAR FIRE T.G. 11 NON- ILLUMINATED GRAPHIC. 12 RECESSED LIGHT BOX FOR ILLUMINATED GRAPHIC . 13 7" ANTIQUE WHITE OAK CLADDING EXTENSION. MELANINE SHELVING 12" DEEP WITH SURFACE MOUNTED STANDARDS 6' LONG, G.C. TO PROVIDE BACKING FOR STANDARDS EMPLOYEE LOCKERS 1 TIER 4 LOCKERS EXTEND (E) NEUTRAL PIER AS REQUIRED FOR (N) STOREFRONT PROJECTION. 17 EXISTING EXPANSION JOINT TO REMAIN 18 BARRICADE GENERAL NOTES 1. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. IMMEDIATELY NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. ALL DIMENSIONS TO EXISTING SURFACES ARE TO FACE OF EXISTING FINISH UNLESSOTHERWISE NOTED. ALL DIMENSIONS LOCATING NEW WALLS ARE TO FACE OF FINISHED WALL UNLESS OTHERWISE NOTED. 3. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS ON THE CONSTRUCTION DOCUMENTS. DO NOT SCALE. 4. ALL NEW INTERIOR DOORS SHALL BE LOCATED SO THAT THE HINGE SIDE IS 4" FROM FACE OF NEAREST WALL UNLESS OTHERWISE NOTED. 5.- 6. ANY NEW ROOF OR WALL PENETRATIONS TO BE APPROVED BY AND FURTHER COORDINATED WITH CONSTRUCTION PROJECT MANAGER AS NECESSARY PRIOR TO ANY WORK BEING DONE. 7. ALL WOOD BLOCKING TO BE FIRE RETARDANT TREATED AS REQUIRED PER SECTION 7/7.2.2, SFBC 2010 8. FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 10 AND THE LOCAL JURISDICTION REQUIREMENTS. USE WALL MOUNTED CABINETS IN SPACES VIEWABLE BY THE PUBLIC AND STANDARD EXTINGUISHER WALL BRACKETS IN AREAS NOT VIEWABLE BY THE PUBLIC. RCP KEY NOTES 0 C SOFFIT WITH WOOD PLANK CLADDING @ 11'-6" A.F.F. 2'x2' A.C.T. BY ARMSTRONG ULTIMA BEVELED TEGULAR EDGE. #1911 @ 13'-0" ACT CEILING @10'-0" 2X4 GRID GWB CEILING @ +13'-0" A.F.F. O (N) ILLUMINATED BLADE SIGN BY SIGN VENDOR PER MALL STANDARDS O NOT USED 07 (N) ACT CEILING @10'-0" 2X4 GRID O (N) GWB CEILING @ 8'-0" AFF SYMBOL LEGEND. A PULRIS ORBIS CMH MULTIPLE DIRECTIONAL RECESSED SERIES T4 (2) HEADS, ICL-R-GU65-2 20W EMERGENCY EXIST SIGN W/ EMERGENCY LIGHTS 2X4 DROP -IN FLUORESCENT FIXTURE W/ 4 TUBES REVIEWED FOR E COMPLIANCE APPROVED APR 1 1 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 11 2014 PERMIT CENTER 4 fir -40, cssociatcs • ARCHITECTURE • INTERIORS • PLANNING T ECTA 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7318 REGISTERED ARCHITECT AHMAD MOHAZAB STATE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 Co Lo co 1 LL.'w F— OQ Z 0- to W 1 CD CO M J WT oimi I"" < 2 Q O ct Cn W Lli J I— L_J U Q (Q' LL = W 1-- F. cv) CO D w �0�/J� V a) co N---- NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES - IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED. FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES, THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT. 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTEC110N ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: ADESIGN . SUBMITTED TO LL FOR APPROVAL 01/15/14 CD'S SUBMITTED TO LL, PERMIT VENDORS FOR APPROVAL 02/07/14 ABUILDING DEPARTMENT SUBMITTAL 02/17/14 A : . ISSUE. DATE: . SPACE PLAN DATE: 12/19/13 DRAWING TITLE: CONSTRUCTION PLAN & REFLECTED CEILING PLAN DRAWING NUMBER: A-1.O 0 STORAGE AREA L 02 \\\\\\\\\\\\• HDCP RESTROOM 003 CI _ 0 SALES AREA 001 8" = = _ = FLOOR FINISH PLAN Scale: 1/4" = 1'-0" /� 0 8'-0"L x 12"D HDCP RESTROOM 003 STORAGE. AREA 002 c?, O `r) 0 M O c1 • M M O M cM • C'4' 1_n II ❑-❑ 2" 1'-6" 3'-0" L__J 3'-6" SALES AREA 001 co 3'-0" 3'-0" \ 0 ch • O \ zl 0 u u u u u II 2'_0" 4, 3'-0" C2. FIXTURE / FURNITURE PLAN Scale: 1/4" = 1'-0" SYMBOL LEGEND (N) HARDWOOD FLOORING WHITE WASHED 'WHITE OAK' PLANKS (N) V.C.T. FLOORING (N) CERAMIC TILE FLOORING FINISHES KEY NOTES 0 8" WHITE WASHED WHITE OAK PLANKS 0 NOT USED 0 V.C.T. FLOORING 0 CERAMIC TILE FLOORING 0 PROVIDE TRANSITION STRIP AS REQUIRED PROVIDE METAL TRANSITION STRIP, COLOR WROUGHT IRON #2425-10 BY BENJAMIN MOORE WITH RECESSED BLACK SCREWS @ 24" O.C. FIXTURE KEY NOTES 0 MILLWORK CABINETRY 0 RECESSED STANDARDS BY VISPLAY SYSTEMS, INC. (XERO-4G) SEE SHEET A-6.2 03 8MM STARFIRE GLASS SHELVES, 12" DEEP O FREE STANDING TABLE FREE STANDING MILLWORK CABINETRY LOW BASE. END AND BACK PANELS TO BE FINISHED MATERIAL REVIEWED FOR CODE COMPLIANCE APPROVED APR 1 1 2014 • City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL,A FEB 2 0.2014 PERMIT CENTEi 4tkilrAb 441. 401 cssociates • ARCHITECTURE • INTERIORS • PLANNING T ECTA 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7318 REGISTERED ARCHITECT AHMAD MOHAZAB TATE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 CO CO w w O E-- z < W U to c0 _ J CO 2 Q O ct W - � � QF. J z � � W WUQ � W V D V/ W 0 1.0 0) CO NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NDT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.0. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: ADESIGN . SUBMITTED TO LL FOR APPROVAL 01/15/14 •CD'S SUBMITTED TO LL, PERMIT VENDORS FOR APPROVAL 02/07/14 • BUILDING DEPARTMENT SUBMITTAL 02/17/14 • A: ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: FLOOR FINISH & FURNITURE PLAN DRAWING NUMBER: Al...2 0 NEW 1/2" CLEAR ANODIZED ALUMINUM REVEAL, PER MALL STANDARDS 8" ANTIQUE WHITE OAK PLANK CLADDING / MITERED CORNERS AT CHANGE OF PLAIN ROLL DOWN GRILLE HOOD ROLL DOWN GRILLE TRACK GUIDE A.C.T. CEILING, SEE SHEET A-8.2 /...\\/\/\/N 11 11 ro 9 NEW SECTION THRU STOREFRONT Scale: 3/4" = EXISTING MALL CEILING TO REMAIN DEMO EXISTING MALL FASCIA POP OUT BACK TO VERTICAL FRAMING DEMO VERTICAL FRAMING TO L_ ▪ BOTTOM OF MALL FASCIA POP r — OUT ;. 1 r 1 L _J DEMO EXISTING SOFFIT AND TENANT SIGNAGE NEW LEASE LINE EXISTING LEASE LINE LL 1 EXISTING SECTION THRU STOREFRONT Scale: 3/4" = 1'-0" REVIEWED FOR ODE COMPLIANCE . APPROVED APR 1 1 2014 Lir.oc)(90 • City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 202014 PERMIT CENTER associatcs • ARCHITECTURE • INTERIORS • PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com AHMAD MOHAZAB STATE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT ISE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: A. DESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 CD'S SUBMITTED TO LL, PERMIT AVENDORS FOR APPROVAL 02/07/14 A BUILDING DEPARTMENT • SUBMITTAL 02/17/14 A: . A: • • ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: EXISTING AND NEW SECTION THRU STOREFRONT DRAWING NUMBER: A...6 ■ 33" 9 1 O ta9.X. ROLL DOWN GRILLE OPENING 9 1 0 5'-8" 3'-6" PROPOSED STOREFRONT ELEVATION Scale: 1/2" = 1'-0" 8'-0" 6" +/-14'-3" 3EQ. GLASS PANELS /EQ.j/EQ./ 71/4"-� 2 '-0" 3'-0" 6" ROLL DOWN GRILLE OPENING 8'-0" PROPOSED STOREFRONT ELEVATION Scale: 1/2" = 1'-0" / 3'-6" 3'-2" m 1 Ito +/-7'-8 1/2" 1/2" 7 1/4" KEY NOTES 0 NEW ILLUMINATED SIGN/LOGO BOX, FINISH WROUGHT IRON #2425-10 BY BENJAMIN MOORE BY SIGN VENDOR 0 0 0 0 0 NEW BLACK METAL ROLL DOWN GRILLE SURROUND NEW 8" ANTIQUE WHITE OAK PLANKS CLADDING / MIDERED CORNERS @ CHANGE OF PLANES NEW ILLUMINATED BLACK METAL BLADE SIGN BY SIGN VENDOR PER MALL STANDARDS. EXTEND GWB FINISH AS REQUIRED TO MEET (N) 1/2" METAL REVEAL / PAINT TO MATCH MALL COMMON AREA PAINT NEW CLEAR 1/2" ANODIZED ALUM REVEAL NEW 10" BLACK METAL BASE, TYP. PROVIDE REVEAL TO MATCH 10" BASE Og NEW PUSH -THOUGH ILLUMINATED SIGN - SEE SIGN DRAWINGS 10 NEW ILLUMINATED CUTOUT LOGO - SEE SIGN DRAWINGS 11 12 13 NEUTRAL PIER, PAINT TO MATCH CONCOURSE PROVIDE CLEAN TRANSITION @ MALL STOREFRONT TILE NEW ILLUMINATED BLADE SIGN BY SIGN VENDOR PER MALL STANDARDS 15"Hx33"L. 8" HIGH TILE BASE AT NEUTRAL PIER, G.0 TO PURCHASE FROM MALL LANDLORD REVIEWED FOR CAPPROVEDE COMPLIANCE APR 1 1 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL FEB 2 0 ,2014 PERMIT CENTER • ARCHITECTURE • INTERIORS • PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7318 I REGISTERED ARCHITECT t AHMAD MOHAZAB ATE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF 111 DESIGN. NO. REVISIONS: DATE: • DESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 A. CD'S SUBMITTED TO LL, PERMIT VENDORSFOR APPROVAL 02/07/14 A. BUILDING DEPARTMENT SUBMITTAL 02/17/14 A: • ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: PROPOSED ELEVATION STORE FRONT DRAWING NUMBER: A-6.1 X 2'-6" X X 2'-6" X X 2'-6" X X 1 I I X X X I I 2'-6" _ 4'-0" 5'-6" 4'-0" 4'-0" 2'-6" 5'-9" g 2'-6" 0 0 2'-6" 2'-6" 4'-0" 21_6" X 21-6" X X 4' 0,� X X 5'-6" 5'-6" 2'-6" 4'-0" / N. / \ 7 N. / N. 7 \ 7 \ 7 N. 7 \ / \ 7 N. 7 N. 7 N. / \ 7 N. / \ 7 N. 7 \ 7 N. 7 N. / N. / N. 7 N. / N. 7 N. 7 N. / N. 7 N. / EQ / EQ / EQ / EQ / EQ / EQ / EQ EQ EQ EQ EQ EQ EQ EQ / 3'-0" / 3'-0" / 3'-0" / 3'-0" / 3'-0" / 3'-0" 3'-0" INTERIOR ELEVATION INTERIOR ELEVATION Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0" EQ / EQ / E 3'-0" 2'-6" 2'-6" 2'-6" / N. EQ / EQ EQ 3'-0" 3'-0" \\ 0 0 C ) X jr, 24" OI.C. 3'-0I" v X 3'_c'I X X X X 0 0 0 OPEN INTERIOR ELEVATION 12" !i 1'-6" , CLEAR INTERIOR ELEVATION Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0" g I. REVIEWED FOR f4PE COMPLIANCE APPROVED 0 0 KEY NOTES ACOUSTIC CEILING TILES SUPER GRAPHIC IN ALUM. FRAME - ILLUMINATED P-1 BENJAMIN MOORE - WROUGHT IRON #2124-10 WHITE CORIAN W/ 3" BACKSPLASH THROUGHTOUT SINK COUNTER. ALUM. DOOR IN ALUM. FRAME W/ FULL WEIGHT MIRROR PANEL. 0 0 0 0 BLACK METAL SIGN BOX BY SIGN VENDOR. 7" ANTIQUE WHITE OAK PLANKS CLADDING VINLY DECALLS OF ORGANIC HERBS/ FRUITS AND VEGETABLES ON PAINTED WALL. P-2 BENJAMIN MOORE ANTIGUAN SKY #2040-60 STAR FIRE GLASS SHELVES. MDF CABINETS - PAINT FINISH EGG SHELL LINEN WHITE BY BENJAMIN MOORE #912 11 © 13 4" BLACK WOOD BASE SUPER GRAPHIC IN ALUM FRAME - NON ILLUMINATED VISPLAY SYSTEM - XERO 4G VISPLAY, INC. 7528 WALKER WAY ALLENTOWN, PA 18106 (610) 366-1658 SEE 18/A-8.0 14 ANTIQUE WHITE OAK PLANKS COUNTERTOP WI 2" SOLID WOOD EDGE 3" ANTIQUE WHITE OAK BACK SPLASH 16 10" METAL BASE 17 SIDES OF WALL TO BE CLAD IN METAL PANEL TO MATCH ADJACENT SIGN BOX. GENERAL NOTES ALL MILLWORK COUNTERS - ANTIQUE WHITE OAK PLANKS WI 2" EDGE / COUNTER TOP TURN TO GO TO THE BASE OF CABINETS & ALL EXPOSED EDGES / 3" ANTIQUE WHITE OAK BACKSPLASH UON. APR 1 1 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 ,0 2014 PERMIT CENTEP, c ssocic tes ® ARCHITECTURE o INTERIORS ® PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7 18 REGISTERED ARCHITECT HMAD MOHAZAB OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 (0 co W a— U < W �- �CO = J co SS O W W W WU� U . = W �— E— C/) u 0 Cn co NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAYANGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK- UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: A. DESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 AVENDORS CD'S SUBMITTED TO LL, PERMIT FOR APPROVAL 02/07/14 ABUILDING DEPARTMENT SUBMITTAL 02/17/14 A• • ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: INTERIOR ELEVATIONS DRAWING NUMBER: -6.2 SIGNAGE IS TO COMPLY WITH CBC 11176.5.7 FOR LOCATION & 1115B.5 FOR DESIGN NOTE: SIGNAGE SHALL BE 1/4" THICK & THEIR COLOR & CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THAT OF DOOR GRAB BAR: LOCATE GRAB BARS ON EACH SIDE OF WATER CLOSET OR ONE ON SIDE AND ONE BEHIND WATER CLOSET. SIDE GRAB BARS ARE TO BE 3'-6" LONG WITH THE FRONT END 2'-0" IN FRONT OF WATER CLOSET. GRAB BARS AT THE BACK CANNOT BE LESS THAN 3'-0". GRAB BARS SHALL NOT ROTATE AND THERE ARE TO BE NO SHARP OR ABRASIVE ELEMENTS ON OR ADJACENT TO THEM. EDGES ARE TO HAVE A MINIMUM 1/8" RADIUS SIGNAGE: IDENTIFICATION SYMBOLS. DOORWAYS LEADING TO MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE 1/4" THICK W/ EDGES 12" LONG AND A VERTEX POINTING UPWARD. WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 1/4" THICK AND 12" IN DIAMETER. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK, 12" IN DIAMETER W/ A 1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12" DIAMETER. THESE GEOMETRIC SYMBOLS SHALL BE CENTERED ON THE DOOR AT THE HEIGHT OF 60" AND THEIR COLOR AND CONTRASTS SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRASTS OF THE DOOR ALSO PROVIDE PERMANENT SIGNS IN RAISED (1/32 INCH MINIMUM) LETTERS OF SANS -SERIF UPPERCASE CHARECTERS ACCOMPANIED BY GRADE-2 BRAILLE. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. (WALL BRAILLE SIGN MOUNTED @48" MIN. AFF MEASURED FROM THE BASELINE OF THE LOWEST LINE OF BRAILLE AND 60" MAX. AFF MEASURED FORM BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. 2010 CBC SECTION 11176.5.7.) MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF DOOR. LAVATORIES: 2'-10" IS THE RECOMMENDED HEIGHT FROM THE FLOOR TO THE TOP OF THE LAVATORY. INSULATE OR COVER ALL HOT WATER AND DRAIN PIPES UNDER LAVATORY. NO SHARP OR ABRASIVE EDGES ALLOWED UNDER LAVATORY. GENERAL: FAUCET CONTROLS AND OPERATING MECHANISMS MUST BE EASILY OPERATED BY ONE HAND AND MUST NOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE NEEDED TO ACTIVATE CONTROLS SHALL NOT EXCEED 5 LBS. FOR LEVER OPERATED OR 15 LBS. FOR PUSH TYPE TOILET ROOM SIGNAGE 12" UNISEX SIGNAGE H.C. ACCESSIBILITY SYMBOL WALL BRAILLE SIGN MOUNTED @48" MIN. AFF MEASURED FROM THE BASELINE OF THE LOWEST LINE OF BRAILLE AND 60" MAX. AFF MEASURED FORM BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. 2010 CBC SECTION 1117B.5.7. • CO 0 \ \ I I CLEAR FLOOR SPACE jr 2'-6 jr SIGNAGE LOCATION @ TOILET ROOM DOOR LAVATORY URINAL PAPER TOWEL COMBINATION TOWEL AND TOILET SEAT DISPENSER WASTE DISPENSER COVER DISPENSER HAND DRYER TRASH NAPKIN DISPENSER F.F MISC. HEIGHT REQUIREMENTS THERMOSTAT i FIRE ALARM OR HEAD OF FIRE EXTINGUISHER CUP DISPENSER SWITCH RECEPTACLE HEIGHT REQUIREMENTS AND NOTES 36" MIN 2'-0" q. 12" Cr) 18" Scale: NONE 0 A RESTROOM ELEVATIONS 16"-18" Scale: 1/2" = 1'-0" x 0 8" 17" a, N MIN. TYPICAL HANDICAP TYPE LEVER TO BE USED / 90 3/4" 18" 36" 16"-18" i � I L 48x30J 60x60 • BATHROOM REMEDIATION NOTES: 1. PROVIDE OFFSET FLANGE AND RELOCATE TOILET TO 18" FROM WALL. 2. RELOCATE REAR GRAB BAR TO CORRECT LOCATION. 3. RELOCATE TOILET TISSUE TO CORRECT LOCATION. 4. PROVIDE SEAT COVER DISPENSER PER ELEVATION. (E) TILE BASE A C J/ HDCP /RESTROOM 003 I® ® ®I® I® El i I ENLARGED RESTROOM PLAN Scale: 1/2" = 1'-0" 0 REVIEWED FOR CODE COMPLIANCE APPROVED APR 1 1 2014 • City of Tukwila BUILDING DIVISION 8" /MIN/ 17" / . MIN. a) 2 Er) N 2 d (1) RECEIVED CITY OF TUKWILA MAR 1.8 2014 PERMIT CENTER associates ® ARCHITECTURE • INTERIORS ® PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com t.,),7318 REGISTERED ARCHITECT ARCHITECTURAL PROJECT NO.: 13.145 NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT UNITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: ADESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 A. SUBMITTED TO LL, PERMIT VENDORS FOR APPROVAL VENDORS 02/07/14 ABUILDING DEPARTMENT SUBMITTAL 02/17/14 PLAN CHECK COMMENTS BUILDING DEPT RESUBMITTAL 03/11/14 ./•\• • ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: ENLARGED RESTROOM PLANS AND ELEVATIONS DRAWING NUMBER: -6.3 17 1 /4" / 24" / 24" INO STORAGE ABOV E THIS LINE 11 3" RED STRIP W/ THE LETTERS "NO STORAGE ABOVE THIS LINE" IN WHITE LETTERS PER RFC SEC. 315 SURFACE MOUNTED WALL STANDARDS G.C. TO PROVIDE BACKING TO SUPPORT STANDARDS, TYP. 3/4" THICK MELANINE ADJUSTABLE SHELVES, TYP. STORAGE AREA ELEVATION Scale: 1/2" = 1'-0" SURFACE MOUNTED WALL STANDARDS G.C. TO PROVIDE BACKING TO SUPPORT STANDARDS, TYP. 3/4" THICK MELANINE ADJUSTABLE SHELVES, TYP. 24" 24" 24" 3/4'2 4" 0 STORAGE ABOVE THIS LINE I I 13" RED STRIP W/ THE LETTERS "NO ;STORAGE ABOVE THIS LINE" IN 'WHITE LETTERS PER RFC SEC. 315 STORAGE AREA ELEVATION Scale: 1/2" = 1'-0" SCHLUTER DECO STRIP SATIN ANODIZED ALUM. TENANT MALL 8" WIDE WOOD PLANKS PROVIDE GROUT TO MATCH MALL GROUT EXISTING MALL TILE TO REMAIN. SCHLUTER STRIP DETAIL @ MALL TILE Scale: 1/2" = 1'-0" 8'-0" A ROLL DOWN GRILLE NEW ROLL -DOWN GRILLE BRUSHED S.S. HINGE BRUSHED STAINLESS STEEL DOOR FRAME NO STOPS MIRROR FINISH SALES SIDE 24" LONG LADDER STYLE BACK-TO-BACK PULLS BRUSHED STAINLESS #24LPBS BY C.R. LAURENCE CO. INC. 3'-0" \ 10" KICK/BRUSHED S.S. / / t PROVIDE BRAILLE 6 HERCULITE DOOR w/FROSTED GLASS 3'-0" m 0 C EQ EQ. PROVIDE TOILET ROOM SIGNAGE RESTROOM DOOR DOOR SCHEDULE DOOR MARK QTY. REQ'D ELEV. TYPE DOOR SIZE REQ'D SPECIAL NOTES 1 A 8'-0" WIDE ROLL DOWN GRILLE 100 > 1 A 8'-0" WIDE ROLL DOWN GRILLE 101 > 1 B 3'-0" x 6'-8" HERCULITE DOOR WITH MIRROR GLASS ON SALES SIDE / BRUSHED S.S. FRAME NO CLOSER 102 1 C 3'-0" x 6'-8" PROVIDE HDCP SIGNAGE 102 > FINISH SCHEDULE MARK DESCRIPTION APPLICATION SPECIFICATION WALLS BENJAMIN MOORE WALLS BENJAMIN MOORE ANTIGUAN SKY #2040-60 P-1 BENJAMIN MOORE SOFFIT BENJAMIN MOORE WROUGHT IRON #2124-10 P-2 BENJAMIN MOORE CABINETS BENJAMIN MOORE LINEN WHITE # P-3 W4 BASE ' B1 • B2 CEILING 2'x2' A.C.T. BY ARMSTRONG SUSPENDED CEILING ULTIMA BEVELED TEGULAR EDGE (1911 OR 1912) BY ARMSTRONG C1 •' C2 • - C3 • ' F1 FLOORING • ' F2 • ' F3 • ' F4 REVIEWED FOR ODE COMPLIANCE :.:' APPROVED APR i 1 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0.2014 PERMIT CENTER *64 th , i 1 ... .. fli, 0" - wig, iillra T ECTA associc ® ARCHITECTURE ® INTERIORS ® PLANNING tes 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7318 REGISTERED ARCHITECT AHMAD MOHAD% ATE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 CSC LC) Et CO W W F-O Z Q o C) W Co = J 00 � QR--:,„ D 2 Q �/�ct 0 vJ W W CI Z —I W W UQ� LL Z W I— 1— (/) v! W0 U) 0) M r NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT UNITED TO THE OVERALL FORM A5 WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: AFOR DESIGN SUBMITTED TO LL APPROVAL 01/15/14 CD'S SUBMITTED TO LL, PERMIT VENDORS FOR APPROVAL 02/07/14 ASUBMITTAL BUILDING DEPARTMENT 02/17/14 • ISSUE DATE: . SPACE PLAN DATE: 12/19/13>. DRAWING TITLE: SCHEDULES, STORAGE ELEVATIONS DRAWING NUMBER: ME 7 0 2'-0" BLOCKING SECURED TO EXISTING FRAMING WITH SELF -TAPPING SCREWS VISPLAY STANDARD - ZERO 4G NEW MDF PANEL BETWEEN STANDARDS EXISTING GWB TO REMAIN EXISTING FRAMING TO REMAIN V.I.F. (E) NEUTRAL PIER 3/4" BLACK METAL REVEAL CHANNEL. REPAIR / REPLACE AS REQUIRED. MITERED CORNER. (N) 3/4" WD FASCIA- REMOVE (E) GWB & REDO (E) SUBSTRAIT AS REQUIRED TO INSTALL IN (E) PLANE. * NOTE - REVEAL IS TO HAVE AS NEW APPERANCE 18 VISPLAY DETAIL SCALE: N.T.S. STOREFRONT NEUTRAL PIER TRANSITION SCALE: 1 1/2"=1'-0" 0 CV _ _/ Y,N 17" MIN. 3" CV CV FAUCET, GROHE ALLURE #20191000 BACK SPLASH - CORIAN CORIAN COUNTERTOP DOORS WITH SELF -CLOSING CONCEALED HINGES AND TOUCH LATCHES KOHLER KATHRYN #K-2297-G ADA UNDER COUNTER MOUNT SINK MELAMINE INTERIOR PIPE WRAP PER CODE 1115B.4.7.1 & 2 NOTE: DOORS W/ ATTACHED TOE KICK STILL GIVES A CLEAR FLOOR SPACE OF 30x42 CV 4" / / 4 CABINET DETAIL 1 1/2 =1-0 MITERED EDGE 4" TILE BASE MITERED EDGES 1 1/2" MDF DOOR w/ TOUCH LATCH HARDWARE 1 ADJUSTABLE SHELF 4" TILE BASE TOUCHATCH HARDWARE ADJUSTABL SHELF 9 SINK BASE ADA CABINET STANDARD DETAIL SCALE: 1 1/2" = 1'-0" CABINET DETAIL 1 1 /2"=1'-0" 0 NOT USED SCALE: 3/4"=1'-0" STRUCTURE @ 15'-1" 4" MTL STUDS @16" O.C. GWB CLG @ 13'-4" 5/8" GWB 4" 22 GA. MTL STUDS @ 16" O.C. GWB TO 6" ABOVE GRID 5 3/4" PERIMETER SOFFIT DETAIL SCALE: 1 1/2"=1'-0" ACT @ 11'-5" ROHE ALLURE FAUCET #20191000 KOHLER KATHRYN SINK #K-2297-G WHITE CORIAN COUNTERTOP ANTIQUE WHITE OAK PLANK BACK SPLASH ANTIQUE WHITE OAK PLANK COUNTERTOP 7 i 7 7 7 7 /. / 7 N. N. / \ / / / / / / / / / / \ \ / N. 7 \ / 7 7 / 7 / i / / i / \ i MDF CABINETS PAINT r \ / FINISH - EGG SHE)..t LINEN WHITED# 9'12 BY \ \ BENJAMIIVotOORE 7 7 7 \ \ MITERED EDGE CABINET BEYOND 4" TILE BASE MITERED EDGES 2 CABINET DETAIL 1 1 /2"=1'-0" 5 CABINET DETAIL 1 1/2"=1'-0" BOTH DOORS IN SINK BASE NEED TO BE ADA ACCESSIBLE. THE TOE KICK IS ATTACHED TO THE DOORS 4" TILE BASE MITERED EDGE REVIEWED FOR NCE BUILDING DIVISI 1 1/2"X8" ANTIQUE R CEIVED WHITE OAK PLANK TQ iTV OF TUKWILA CABINET DETAIL 1 1/2"=1'-0" FEB 2 0 2014 PERMIT CENTER C ssociates • ARCHITECTURE • INTERIORS • PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com ARCHITECTURAL PROJECT NO.: 13.145 NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO SE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS 111E ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: A. DESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 AVENDORS CD'S SUBMITTED TO LL, PERMIT FOR APPROVAL 02/07/14 • BUILDING DEPARTMENT SUBMITTAL 02/17/14 ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: DETAILS DRAWING NUMBER: 12 GRILLE BOTT TRACK 8" ANTIQUE WHITE OAK' CLADDING PLANKS ATTACHED TO SOFFIT OVER 5/8" TYPE 'X' GWB OVER 3 5/8" 20GA METAL, STUDS @ 16" O.C., TYP. 4" V.I.F. ANTIQUE WHITE OAK PLANK ATTACHED TO GRILLE BOTTOM TRACK 5/8" MDF PANEL WITH END CAP BLOCKING AS REQUIRED EDGE OF CABINETS NEW 3 5/8" 20 GA. METAL STUDS @ 16" O.C., TYP. 5/8" TYPE 'X' GWB BOTH SIDES BLOCKING AS REQUIRED 8" ANTIQUE WHITE OAK PLANK CLADDING, MITERED CORNERS AT CHANGE OF PLAIN 3/8" STARFIRE TEMPERED STOREFRONT GLASS •Q 4 1/2' DEFLECTION SPACE BETWEEN MTL. STUD AND (E) STRUCTURE. TYP (E) STRUCTURE . d Q• a . 5/32' DIA POWDER DRIVEN FASTNER @ 16" O.C. MAX W/ 1 14" EMBED. CONT 16 GA MTL. PLATES SPANNING (2) FLUTES MIN. FASTEN RUNNER TO PLATE POCKET AT SOFFIT FOR ROLL DOWN GILLE FOOT SCALE: 3"=1'-0" �4 STOREFRONT GLASS TO WOOD WALL FINISH SCALE: 3 =1-0 1 WALL CONNECTION TO PARALLEL DECK SCALE: 1 "=1'-0" 8" ANTIQUE WHITE OAK CLADDING PLANKS WITH MITERED CORNERS AND AT CHANGE OF PLAIN 5/8" TYPE 'X' GWB OVER 3 5/8" 20GA METAL STUDS @ 16" O.C. TYPICAL 3/8" STARFIRE STOREFRONT GLASS, G.C. TO VERIFY THE THICKNESS BEFORE PURCHASING GLASS 1/2" OR 3/8" NEW TUBE STEEL POST FOR ROLL DOWN GRILLE TRACK FOR ROLL DOWN GRILLE 16GA METAL CLADDING, FINISH TO MATCH SIGN BOX 6" FINISH OF TRACK TO MATCH CLADDING ROLL DOWN GRILLE 3/8" STARFIRE TEMPERED STOREFRONT GLASS LEASE LINE 10 STOREFRONT GLASS AT SOFFIT / SCALE: 6 =l -0 DETAIL AT ROLL DOWN GRILLE POST TO STOREFRONT GLASS SCALE: 3 =1-0 a 4 1/2" DEFLECTION SPACE BETWEEN MTL. STUD AND (E) STRUCTURE. TYP 5/32" DIA POWDER DRIVEN FASTNER @ 16" O.C. MAX W/ 1 1/4' EMBED. RUNNER 2� WALL CONNECTION TO PERPENDICULAR DECK SCALE: 1 =1-0 METAL CLADDING AT END OF WALL TO MATCH SIGN BOX TRACK FOR ROLL DOWN GRILLE ▪ NEW TUBE STEEL POST FOR ROLL DOWN GRILLE 16GA METAL CLADDING, FINISH TO MATCH SIGN BOX \\\\\\\\\\\\ 6" 1" METAL CLADDING REVEAL, FINISH TO MATCH SIGN BOX 2'-10" 1" METAL CLADDING REVEAL, FINISH TO MATCH SIGN BOX 1' NEW WALL 3 5/8" 20 GA METAL STUDS @ 16" O.C. WITH 5/8" GWB THREE SIDES WITH METAL CLADDING AT END OF WALL TO MATCH SIGN BOX NEW STOREFRONT 3/8" STAR FIRE GLASS NOTE: 1. (4) #10 SCREWS TO ANGLE, TYP 2. 1/2" DEFLECTION SPACE BETWEEN MTL. STUD AND (E) CONCRETE OVER MTL. DECK. TYP Y4" DIA 3" FROM END, TYP.2 1/2' EMBED, EXPANSION BOLT O DECK PARALLEL O DECK PARALLEL L 3"X3"X%4"X18" LONG, TYP L3"X3"X1 /4"X1'-4" W/(2) %"0 WEDGE ANCHORS W/3Y4'0 EMBED. TYP EACH SIDE DBL 3 %"X18 GA @ 48"O.C. 11 /2" @18" O DECK PERPENDICULAR 3%6" O DECK PERPENDICULAR 6� DETAILATROLL DOWN GRILLE TO SIGN BOX SCALE: 1 1/2, =1-0, %3 TYPICAL WALL CONNECTION AT DECK SCALE: N.T.S. REVIEWED FOR CODE COMPLIANCE APPROVED APR 1 1 2014 l City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 202014 PERMIT CENTER associates • ARCHITECTURE ® INTERIORS ® PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7318 REGISTERED ARCHITECT AHMAD MOHAZAB TE OF WASHINGTON ARCHITECTURAL PROJECT NO.: 13.145 NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES 'IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT UNITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: DESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 AVENDORS CD'S SUBMITTED TO LL, PERMIT FOR APPROVAL 02/07/14 ABUILDING DEPARTMENT SUBMITTAL 02/17/14 ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: DETAILS DRAWING NUMBER: CEILING NOTES: METAL CEILING SUSPENSION SYSTEMS USED PRIMARILY TO SUPPORT ACOUSTICAL TILE OR OTHER LAY -IN PANELS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ASTM C 635 AND ASTM C 636 LATERAL DESIGN REQUIREMENTS: SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORIES D, E, AND F SHALL BE DESIGNED AND INSTALLED TO MEET REQUIREMENTS IN ACCORDANCE WITH THE PROVISIONS OF ASTM C 635, ASTM C 636. 1. A HEAVY-DUTY T-BAR GRID SYSTEM SHALL BE USED. 2. EACH SUSPENDED CEILING AREA SHALL BE PROVIDED WITH CLOSURE ANGLES NOT LESS THAN 2" IN WIDTH. IN EACH ORTHOGONAL HORIZONTAL •DIMENSION. ONE END OF CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END SHALL HAVE A 0.75"CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON THE CLOSURE ANGLE. 3. FOR CEILING AREAS EXCEEDING 1000 S.F., HORIZONTAL RESTRAINT OF THE CEILING TO THE STRUCTURAL SYSTEM SHALL BE PROVIDED. THE TRIBUTARY AREAS OF THE HORIZONTAL RESTRAINTS SHALL BE APPROXIMATE EQUAL. 4.•FOR CEILING AREAS EXCEEDING 2500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITIONS THAT BREAK THE CEILING UP INTO AREAS NOT EXCEEDING 2500 S.F. SHALL BE PROVIDED, UNLESS STRUCTURAL ANALYSIS IS PROVIDED. 5. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, CEILING PENETRATIONS INCLUDE SPRINKLER HEADS SHALL BE PROVIDED WITH A 2-INCH OVERSIZE RING, SLEEVE, OR ADAPTER TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIMENSIONS. 6. CHANGES IN CEILING PLAN SHALL BE PROVIDED WITH POSITIVE BRACING. 7. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY FROM THE CEILING. 8. NO FIXTURES/EQUIPMENT W/WEIGHT MORE THAN 20 LBS., OR DISTRIBUTION WEIGHING MORE THAN 5 LBS/FT WILL BE SUSPENDED FROM OR MOUNTED ON ROOF, CEILING, OR WALL STRUCTURE MORE THAN 4 FT A.F.F. WILL BE INCORPORATED IN THIS PROJECT. #10 TEK SCREW THRU 3/4" CONDUIT TO 16 GA. METAL ANGLE HILTI CC CEILING CLIP WITH 2" #10 VERTICAL 12 GA. HANGER WIRE @ 4'-0" O.C. SELF -TAPPI NG WOOD SCREW ATTACHED TO STRUCTURE BY 2" #10 SELF -TAPPING WOOD SCREW 3" x 3" METAL ANGLE 3/4" E.M.T. - RUN TIGHT TO STRUCTURE ABOVE ENTIRE CEILING SYSTEM INCLUDING LICHTS, DUCTS ETC. SHOULD WEIGH LESS THAN HANGERS SHALL BE PLUMB AND SHALL NOT PRESS AGAINST CONDUITS, DUCTS, PIPES OR THEIR COVERING MATERIAL. WIRE HANGERS FOR SUSPENDING CARRYING CHANNELS OR MAIN RUNNERS FROM AN EXISTING STRUCTURE SHALL BE PREPARED FROM A MINIMUM OF NO.12 GAUGE, GALVANIZED, .SOFT -ANNEALED, MILD STEEL WIRE SPACED 4'-0" ON CENTER. EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER AND TO THE SUPPORT ABOVE WITH A MINIMUM OF THREE TIGHT TURNS IN 1 1/2 INCHES. WIRES SHALL NOT BE ATTACHED TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. HORIZONTAL RESTRAINS SHALL BE EFFECTED BY .FOUR NO.12 GAUGE WIRES SECURED TO THE MAIN RUNNER WITH FOUR TIGHT TWISTS IN 1 1/2 INCHES AND WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER AT THE CONVERGENCE OF THE SPLAYED WIRES SHALL BE EXTENDED TO AND BE FASTENED TO THE ROOF OR FLOOR STRUCTURAL MEMBERS ABOVE OR TO SUCH OTHER FRAMING DEEMED ACCEPTABLE TO THE ENFORCEMENT AGENCY. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED NOT MORE THAN 12 FEET BY 12 FEET ON CENTERS. THERE SHALL BE A RESTRAINT POINT A DISTANCE OF NOT MORE THAN ONE HALF OF THE ABOVE SPACING FROM EACH SURROUNDING WALL. ALATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCTWORK THAT IS NOT PROVIDED WITH BRACING RESTAINS FOR HORISONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A. MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD., WHICHEVER IS GREATER,WITH A SAFETY FACTOR OF 2 WITHOUT YIELDING. ALL RECESSED OR DROP -IN LIGHT FIXTURES AND GRILLES SHALL BE SUPPORTED DIRECTLY FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE WITH A MINIMUM NO. 12 GAUGE WIRES LOCATED AT DIAGONALLY OPPOSITE CORNERS. SPLICES AND INTERSECTIONS OF RUNNERS SHALL BE ATTACHED WITH MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP RIVETS, SCREWS, PINS, PLATES WITH BENT TABS, OR OTHER APPROVED CONNECTORS FOR 2x DESIGN LOAD OR ULTIMATE AXIAL OR COMPRESSION (MIN.60 LBS.) SECURE SUPPORT WIRES TO STRUCTURAL MEMBERS ABOVE - NOT TO DECK. ACCEPTABLE STRUT SIZES AND LENGTHS TRADE SIZE ALLOWABLE LENGTH EMT IMC OR PMC 1/2" 3'-10" 4'-4" 3/4" 5'-2" 5'-7" 1" 6'-6" 7'-0" 1 1/4" 8'-6" 9'-0" 1 1/2" 9'-10" 10'-5" 2" 1 1'-2„ ALLOWABLE WIRE TENSION HANGER WIRE SIZE ALLOW.TENSION #12 170# #11 225# #10 300# SEISMIC LOCKING PIN HEAVY DUTY CROSS RUNNER LOCKING CUP TO FASTEN CROSS RUNNER TO MAIN RUNNER HEAVY DUTY MAIN RUNNER THIS DETAIL SHALL BE INSTALLED IF REQUIRED BY LOCAL CODES. LATERAL BRACING IS NOT REQUIRED IN INDEPENDENT CEILING AREAS OF 144 SQ.FT. OR LESS. MAIN RUNNERS SHALL BE INSTALLED PERPENDICULAR TO THE SIDE WALLS AT CORRIDORS AND HALLWAYS. CONNECTIONS TO OVERHEAD STRUCTURE: ALL HANGER AND SPLAYED BRACING WIRES SHALL BE FIRMLY ANCHORED TO OVERHEAD SUPPORT WITH A MINIMUM OF 3 TURNS. CONNECTION DEVICES SHALL HAVE A CAPACITY OF 100 LBS. MINIMUM. SUPPORTS AT LAY -IN OR SURFACE -MOUNTED LIGHT FIXTURES: A TYPICAL NO. 12 GA. HANGER WIRE SHALL BE • INSTALLED WITHIN 3" OF EACH CORNER OF THE 2'-0" X 4'-0"FIXTURE (4 WIRES PER FIXTURE). IN ADDITION, EACH LAY -IN FIXTURE SHALL BE SUPPORTED DIRECTLY FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE W/A MINIMUM OF (2) 12 GAUGE WIRES LOCATED AT DIAGONALLY OPPOSITE CORNERS. ALL DETAILS AND DATA SHOWN ARE IN ACCORDANCE WITH ASTM C635 & C636. LIGHT FIXTURE 4PSF. 0 J cg SPLAY BRACE WIRE HEAVY DUTY MAIN RUNNER ACCOUSTICAL PANEL 1/2" E.M.T. - RUN TIGHT TO STRUCTURE ABOVE (4'-0" MAX. FOR 1/2" DIAM.) 12 GA. VERTICAL HANGER WIRE COMPRESSION STRUT REQUIRED @EACH SEISMIC RESTRAINT 12'-0"O.C. EACH WAY AND WITHIN 6'-0" OF EACH WALL 3/4" E.M.T. - BUTT TIGHT TO 1 5/8" MTL. JOIST FRAMING DRILL 5/32" HOLE FOR 1/8" BOLT AND LOCK NUT AFTER CEILING SYSTEM IS LEVELED (4)-12 SPLAY WIRES - SPLAYED 90[ITROM EACH OTHER AND 45 FROM CEILING PLANE 7/8" CHANNEL FURRING @ 16" 0.C.-SECURE TO 1 /8" MTL. JOIST FRAMING WITH MIN. 8 GA. WIRE 45° MAX. 1 5/8" X 16GA, MTL. J❑IST FRAMING @ 48' ❑,C SECURE SUPPORT WIRES TO STRUCTURAL MEMBERS ABOVE- NOT TO ROOF DECK 3/4"E.M.T. - RUN TIGHT TO STRUCTURE ABOVE 12 GA. VERTICAL HANGER WIRE COMPRESSION STRUT REQUIRED @EACH SEISMIC RESTRAINT 12'-0" 0.C. EACH WAY AND WITHIN 6'-0" OF EACH WALL 1" E.M.T. - NOTCH OVER MAIN RUNNER DRILL 5/32" HOLE FOR 1/8" BOLT AND LOCK NUT AFTER CEILING SYSTEM IS LEVELED VERTICAL 12 GA. HANGER WIRE @ 4'-0" O.C. (4)-SPLAY WIRES - SPLAYED 90° FROM EACH OTHER AND 45 FROM CEILING LANE . e SI\ e0 M• HEAVY DUTY CROSS TEE CONTINUOUS HORIZONTAL STRUT TO PREVENT SPREADING OF RUNNERS #12 MINIMUM GAUGE WIRES ANCHORED DIRECTLY TO STRUCTURE ABOVE. #12 GAUGE HANGER AT EACH CORNER LIGHT SHALL BE ATTACHED TO THE CEILING SYSTEM WITH POSITIVE CLAMP DEVICES. TO EXCEED 4'-C REVIEWED FOR COMPLIANC APPROVED APR 1 1 2014 City of Tukwila BUILDING DIVISION 6" MAX. 45 °MAX. 2" CLOSURE ANGLE. ATTACH CEILING GRID TO ANGLE @ OPPOSITE END. SUSP. CLG DETAIL © WALL 45° MAX, HEAVY DUTY MAIN RUNNER BOTTOM OF STRUCTURE DO NOT BEND SUSPENDED CEILING HANGER WIRE AT POINT OF ATTACHMENT HANGER WIRE (4'-0"0.C.) ATTACH TO GRID MEMBERS WITHIN 3" OF EACH CORNER OF FIXTURE SAFETY WIRES # 12 GA MIN. (DIAG. CORNERS) LIGHT FIXTURE LAY -IN ACOUSTICAL PANEL RECEIVED CITY OF TUKWILA FEB 2 0 2014 C ssociates ® ARCHITECTURE ® INTERIORS ® PLANNING 2747 19TH STREET SAN FRANCISCO, CA 94110 tel. 415-362-5857 fax. 415-362-5044 www.tecta.com 7518 REGISTERED ARCHITECT ARCHITECTURAL PROJECT NO.: 13.145 co M W f— O Z Q W Ci) I- O' W J � WW U Z vJ WO 0) C) NOTICE COPYRIGHT THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF TECTA ASSCOC. AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH TECTA ASSOC. WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. TECTA ASSOCIATES IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO THE COMMENCEMENT OF ANY WORK. THESE DRAWINGS ARE INTENDED FOR DESIGN PURPOSES ONLY AND NOT FOR USE IN CONSTRUCTION UNLESS APPROVED AS SUCH BY GOVERNING AUTHORITIES. THESE PLANS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SEC. 102 OF THE COPYRIGHT ACT. 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECIURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. NO. REVISIONS: DATE: ADESIGN SUBMITTED TO LL FOR APPROVAL 01/15/14 AVENDORS CD'S SUBMITTED TO LL, PERMIT FOR APPROVAL 02/07/14 ABUILDING DEPARTMENT SUBMITTAL 02/17/14 ISSUE DATE: SPACE PLAN DATE: 12/19/13 DRAWING TITLE: DETAILS DRAWING NUMBER: PERMIT CENTER