HomeMy WebLinkAboutPermit D14-0069 - RIVERTON APARTMENTS - BUILDING A EXTERIORRIVERTON APARTMENTS BLDG A 14461 41 AVE S D14-0069 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0040000244 1446141AVE S8 DEVELOPMENT PERMIT Project Name: RIVERTON APARTMENTS - BLDG A Permit Number: D14-0069 Issue Date: 8/5/2014 Permit Expires On: 2/1/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 MEGAN BEAUCHESNE Phone: (206) 574-1219 700 ANDOVER PARK W, SUITE C , TUKWILA, WA, 98188 C E & C INC Phone: 3221 CENTER ST, TACOMA, WA, 98409 CEC****346L7 Expiration Date: 9/30/2014 KING COUNTY HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 DESCRIPTION OF WORK: BUILDING A: 14461, 14463, 14465, 14467, 14469, 14471: 1 OF 7 BUILDINGS. PROVIDE EXTERIOR UPGRADES TO SIX (6) TWO-STORY APARTMENT BUILDINGS AND ONE(1) ONE-STORY MANAGEMENT BUILDING. UPGRADES INCLUDE BUT ARE NOT LIMITED TO : - REPLACE (E) SIDING, MOISTURE BARRIER, FLASHING AND TRIM - REPLACE (E) MANSARD ROOFING WITH NEW GABLE OVER -FRAMED ROOF ON TYPE 1 BUILDING (A, C & F) - REPLACE (E) EXTERIOR DOORS AND WINDOWS - CONSTRUCT ENTRY CANOPIES - DEMOLISH AND REPLACE (E) WOOD DECKS AND GUARDRAILS. Project Valuation: $75,000.00 Fees Collected: $2,126.52 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: VB Occupancy per IBC: R-2 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 International Fuel Gas Code: 2012 International Residential Code Edition: 2012 WA Cities Electrical Code: 2012 International Mechanical Code Edition: 2012 WA State Energy Code: 2012 Uniform Plumbing Code Edition: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized SignaturDate: oWl 1 I hearby certify that I have read an examined this permit and know the same to be true and correct. All provisions of law and ordinances g erni g this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date: ei/V/y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 8: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 9: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 10: All wood to remain in placed concrete shall be treated wood. 11: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 12: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 15: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 16: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 17: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 18: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0201 FOOTING 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0401 ROOF SHEATHING 0603 ROOF/CEILING INSUL 4037 SI-CAST-IN-PLACE 4000 SI-CONCRETE CONST 4043 SI-E.I.F.S 4046 SI-EPDXY/EXP CONC 4032 SI-WOOD CONST 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1 "i i0O �j q Project No. Date Application Accepted:~`' H Date Application Expires: q - 3 t (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 0040000240 (& 244) 4044 South 146th Street; Tukwila,WA 98168 Suite Number: Bldg. A Floor: 2 Tenant Name: King County Housing Authority New Tenant: ❑ Yes 21..No (Building A: 14461, 14463, 14465, 14467, 14469, & 14471 41st Ave S) PROPERTY OWNER Name: King County Housing Authority Address: 700 Andover Park West, Suite C City: Seattle State: WA zip: 98188 CONTACT PERSON- person receiving all project communicatio Name: Megan Beauchesne Address: 700 Andover Park West, Suite C City: Seattle State: WA zip: 98188 Phone: (206) 574-1219 Fax: Email: meganb@kcha.org GENERAL°CON CTO I I ORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: ARCHITECT OF RECORD ; Company Name: ORB Architects Architect Name: Geoff E. Anderson, AIA Address: 350 South 38th Court, Suite 210 City: Renton State: WA zip: 98055 Phone: (425) 226-3522 Fax: (425) 226-9115 Email: geoffa@orbarchitects.com ENGINEER OF R CORD Company Name: PCS Stuctural Solutions Engineer Name: Rick Oehmcke, S.E Address: 811 First Avenue, Suite 620 City: Seattle State: WA Zip: 98104 Phone: (206) 292-5076 Fax: Email: ROehmcke@pcs-structural.com ONif ALTER (required for projects$500 or greater per Ctlit 1 7.095) Name: King County Housing Authority Address: 600 Andover Park W. City: Seattle State: WA Zip: 98188 H:Wpplications\Fomis-Applications On Linet2011 Applications\Penna Application Revised - 8-9-11 .docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 75,000 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ Bldg. A: 14461, 14463, 14465, 14467, 14469, 14471; 1 of 7 Buildings. Provide Exterior upgrades to six(6) two-story apartment buildings and one(1) one-story management building. Upgrades include but are not lirneted to: - Replace (E) siding, moisture barrier, flashing and trim - Replace (E) mansard roofing with new gable over -framed roof on Type 1 buildings (A, C & F) - Replace (E) exterior doors and windows Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I sr Floor 2,791 0 0 0 V-B R2 2°a Floor 2,791 3rd Floor 0 Floors thru 0 Basernent 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 392,868 Floor area of principal dwelling: 0 Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 48 Compact: Handicap: 4 Will there be a change in use? ❑ Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicationsforms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: Y\AD. VrttrIA0 J\ ROCOC.11 Mailing Address: 700 Andover Park W. Date: 03/03/2014 Day Telephone: (206) 574-1219 Seattle WA 98188 City State Zip H:1Applications\I onns-Applications On Line\201 I Applications\Pennit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 4of4 PUBLIC WORKS PERMIT INFORMATION 206-433-0179 Scope of Work (please provide detailed information): N/A Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District # 125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site septic s in, provide 2 copies of a current septic design app d by King County Health Department. ❑ .. Highline ❑...Valley Vrew ❑ .. Renton ❑ ...Sewer A . ilability Provided ❑ .. Renton ❑ .. Seattle Submitted with Application (mark boxes which a t I ❑ ...Civil Plans (Maximum Paper Size — 22" x 34' ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Re i ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Ease t(s) 0 .. Maintenance eement(s) ❑ ...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 0 ...Total Cut 0 ...Total Fill cubic yards cubic yards 0 ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Abando ❑ .. Curb ❑ .. Pav ❑.. ❑ .. Rig f-way Use - Profit for less than 72 hours ❑ .. R• -of-way Use — Potential Disturbance ❑.. eptic Tank ant Cut ped Fire Line ❑ ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension blic 0 Private ❑ ❑...WaterMain Extension ublic 0 Private 0 FINANCE INFORMATION Fire Line Size at Property e Number of Public Fire Hydrant(s) 0 ...Water ■ ...Sewer 0 ...Sewage Treatment Monthl Service Bill _ to: Name: Day Telephone: Mailing Addres City ork in Flood Zone Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ... Deduct ter Meter Size Water Meter Refund/Billing: Name: Mailing Address: State Zip Day Telephone: City Slate Zip H:1ApplicationsTorms-Applications On Line\201 1 Applications\Permit Application Revised - 8-9-1 Ldocx Revised: August 2011 bh Page 3 of 4 Cash Register Receipt City of Tukwila Receipt Number R1935 DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK $7,394.90 D14-0068 Address: 14442 41 AVE S 5 Apn: 0040000244 $1,036.55 DEVELOPMENT $987.40 PERMIT FEE R000.322.100.00.00 $982.90 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $49.15 TECHNOLOGY FEE R000.322.900.04.00 $49.15 D14-0069 Address: 1446141 AVE S 8 Apn: 0040000244 $1,315.16 DEVELOPMENT $1,252.75 PERMIT FEE R000.322.100.00.00 $1,248.25 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $62.41 TECHNOLOGY FEE R000.322.900.04.00 $62.41 D14-0071 Address: 14438 41 AVE S Apn: 0040000240 $1,036.55 DEVELOPMENT $987.40 PERMIT FEE R000.322.100.00.00 $982.90 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $49.15 TECHNOLOGY FEE R000.322.900.04.00 $49.15 D14-0072 Address: 14460 41 AVE S 7 Apn: 0040000240 $1,315.16 DEVELOPMENT $1,252.75 PERMIT FEE R000.322.100.00.00 $1,248.25 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $62.41 TECHNOLOGY FEE R000.322.900.04.00 $62.41 D14-0073 Address: 14448 41 AVE S 6 Apn: 0040000240 $1,315.16 DEVELOPMENT $1,252.75 PERMIT FEE R000.322.100.00.00 $1,248.25 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $62.41 TECHNOLOGY FEE R000.322.900.04.00 $62.41 Date Paid: Friday, April 25, 2014 Paid By: KING COUNTY HOUSING AUTHORITY Pay Method: CHECK 241154 Printed: Friday, April 25, 2014 2:55 PM 1 of 2 5r;r'H.15 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY PermitTRAK PAID $7,394.90 D14-0074 Address: 14440 41 AVE S 4 Apn: 0040000240 $1,376.32 DEVELOPMENT $584.80 PERMIT FEE R000.322.100.00.00 $580.30 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 PUBLIC WORKS $750.00 BASE APPLICATION FEE R000.322.100.00.00 $250.00 PERMIT ISSUANCE/INSPECTION FEE R000.342.400.00.00 $250.00 CONSTRUCTION PLAN REVIEW R000.345.830.00.00 $250.00 TECHNOLOGY FEE $41.52 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1935 R000.322.900.04.00 $41.52 $7,394.90 Date Paid: Friday, April 25, 2014 Paid By: KING COUNTY HOUSING AUTHORITY Pay Method: CHECK 241154 Printed: Friday, April 25, 2014 2:55 PM 2 of 2 S YSTL MS Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS ACCOUNT I QUANTITY PAID $811.36 $811.36 $811.36 $811.36 $811.36 D14-0069 Address: 1446141 AVE S 8 Apn: 0040000244 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1362 R000.345.830.00.00 Date Paid: Monday, March 03, 2014 Paid By: KC HOUSING AUTHORITY Pay Method: CHECK 239589 Printed: Monday, March 03, 2014 3:49 PM 1 of 1 (6 Dry-c ? INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Projeft: YLxJe,rh L, `R ac.e- Type of inspection: 6.(f Address: f If ti(01 14/ fr/Fv , •fig Date Called: Specie Instructions: dyidi i..� Date Wanted: a.m. 3 i Li '( f". p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: frame I nspector: -`� —/s REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. (-- INSPECTION RECORD Retain a copy with permit CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 �,/ Prtrf0A - f.�—gdyit Type of Inspection: r«1 Address: ! 1cfi 6t VIAVe-ro . Date Called: Spe Instnrc s: f Date Wanted: Z.. --'t a.m. p.rn. Requester. Phone No: Approved per applicable codes. COMMbitS: Corrections required prior to approval. csetit<kt(QA Alb t 1k- Inspector. PEA ON FEE Z-7 REQUIRED. rj NEINS Prior to next inspection. fee must be i paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD/Y7 Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., e100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (mo) 438-9350 t rP4( `t(t R Type of topettion/ ress: if 61 to r',4v'e-50. Date Called: Instructions:m. 4M Date Want is_ a. "T401.17C7 cot S/ Pone No: DAP end per applicable codes. COMMENTS: CertA - e /( 1 cQ/( %' it-trpeJrar1 Corrections required prior,to approval, tn5t01. REINSPECTICN FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION C 70 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 431-2451 PERMIT NO. Pr91ect: 1�\,pc) A-$ 'type f Inspection: r t `a.,�, �.- Addre s: I � 1 0 Date Calved. SpecialInstructs • _ A %A,.� 'bate WRted: 1 i i "'i m. P: Requesterz_r Phone No: �s - �� �/ V Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 1 2 — 14 IN3 e1'ION"FEE REQUIREb. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER bit(- OOe8)or. 04 c 1 6o-7I 10t PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Proje •66 bv1 V Q (.7---((C °g Type of Inspection: Arm l 5 -e c -? p - ,, i Address: Suite #: > (/c/,2„01 / `( 1 / If f ( L/Z Contact Person: i r\ / Special Instructions: /`7`i ej /%/tf6Q / 't/if l Phone No.: 6//C4- Mg 5 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ( ,;--\ j .Di t(-- 00 o ct — v*.- of c,Q ( C 1) ( t,(i r /" 1 0/IA/ i/I -. r r .4; fn AciF- _ . - C t ``'# - OO l 3 - .1 Pv,-, 2°, ,.,L./ (A 4(d . A Di 4- / } f 1 4 \ - -..-.. c ky 1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,- ` -5 Date: ,./0-6// C Hrs.: c" $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 -- mos. MIIIP111 -. (raZarl & ASSOCIATRS, INC' GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION , February 12, 2015 City of Tukwila Attn: Bldg Dept 6200 Southcenter Blvd. Tukwila, WA 98188 RE: Final Letter Riverton Apartments 14440 41st Ave S. Tukwila, WA 98168 To Whom It May Concern: KA No. 066-14219 Permit No. D14-0069 D14-0072 D14-0073 D14-0068 D 14-0071 D14-0070 D14-0074 In accordance with your request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: • Reinforcing Steel • Diaphragm Nailing • Cast in Place Concrete • Proprietary Anchors • Lateral Framing To the best of our knowledge, all work which has been tested and/or inspected has been found to be in general accordance with the approved plans and specifications, engineering revisions, and Chapter 17 of the 2012 International Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939-2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC William B Throne Operations Manager Puyallup RECElVEQ FEB 17 2015 CC: King County Housing Authority With Offices Serving The Western United States 922 — Valley Avenue NW Suite 101 • Puyallup, WA 98371 • (253) 939-2500 • Fax: (253) 939-2556 C.c.RTIFICATE OF INSULAI ION DWELLING INFORMATION ePtoi ex 'k0reN 4 'CONTRACTOR INFORMATION ADqIIESS OF RESIREtic (��� i x'e' J ' 0, ► O ! a l Leg DATE INSULATION WAS INSTALLED: $ /j 4 NAME: ARROW INSULATION, INC ADDRESS: PO BOX 2176 Mount Vernon, WA 98273 1-877-658-WARM Area Insulated / Area Identlfl (Inserts 'area -specific' Info In spate provided) Square Footage Existing R Value Added R Value Final R Value Type of insulation & Method of Installation (Standard or Dense Pack) Depth k of Bap Attic - Area 1 Attic - Area 2 _ Attic -Area 3 plimS , '-5 32--6 YL: - _s-1$4 1r 4••0aLkoSe '11' 11j Floor - Area 1 ., , Floor - Area 2 Floor - Area 3 Wall - Area 1 jx'- Lll L Zp: 3 O'1Se r `�l, St .511 in Wall - Area 2 Coo �e,aw , 1210 ,1.- , .•-~0 IT F 3 n � l t LOSE_ 9.r71' Sd t Wall - Area 3 PAId1► t, 2 12.--Q .t _ 1L16" C'5 5 other `tee 21 U a2-d - -7'1 Lazio9,'L c ,� I, /� (print name), certify that this residence was insulated in conformance with all applicable codes, standards, Weetherl:ation Assistance Program, as administered by the S of Wa Ington. ? 15 iy Revised 2/21 regulations, s specifications of the ncome /1- AUTHORIZED SIGNATURE • DAT RIVERTON APARTMENTS - TUKWILA, WASHINGTON FILE COPY perro REVIE CODE C APPROMEDHOTO NTS APR 0 8 2014 City of Tukwila BUILDING DIVISION I' 1C the t'.ex lgg VICINITY M NTS ii(tYs i sy icle Li0MyQi tit:: 44th aotiP rra Le a \a Lag Y LEGAL DESCRIPTION PARCEL NUMBER 0040000240 14448 14450, 14 14 41ST -ADAMS HOME TRS LESS S 10 FT FOR ST PARCEL NUMBER 0040000244: 14442, 144r & 14 46 41ST AVE S -ADAMS HOME TRS E 1/2 S 10 FT FOR ST PARCEL NUMBER 0040000197: i4420, 14422. 14424, 14426, & 14428 41ST AVE S - ADAMS HOME TRS LOT 2 OF AMENDED TUKWILA SP #L06-091 RE, 20090219900002 SD SP DAF - E 3 FT OF LOT 15 TGW LOT 16 BLK 2 C SD PLAT PROJECT DESCRIPTION PROVIDE REPLACEMENT OF EXISTING CAST IRON SANITARY SEWER PIPING, FITTINGS, AND ALL APPURTENANCES ACCESSIBLE WITHIN THE CRAWLSPACES AND EXTERIOR OF THE BUILDINGS. ALL INTERIOR FIXTURES SHALL REMAIN AND ONLY REPAIRED ON A CASE BY CASE BASIS COORDINATED WITH THE OWNER/ENGINEER REPRESENTATIVE. PROJECT DATA 30 UNIT APARTMENT COMPLEX 14440 41s1 Ave. South Tukwitz, WA 98168 6 WOOD FRAME BUILDINGS 6 - 2 STORY RESIDENTIAL BUILDINGS 1 - 1 MANAGEMENT BUILDING (NIC) RD-3600 - ZONE GROUP R2 OCCUPANCY TYPE V - B CONSTRUCTION FIRE ZONE 3 TOTAL SITE AREA = 392,868 SQ FT OR 9.019 ACRES TOTAL (E) FLOOR AREAS: BLDG "A","C" & "F" 1ST FLOOR 2,791 (TYPE 1) 2ND FLOOR + 2,791 BLDG "B" (TYPE 2) BLDG ID" (TYPE 3) BLDG "E" TYPE 4) B DG "G" SUBTOTAL = 5,582 TYPE 1 TOTAL = 16,746 1ST FLOOR 2,975 2ND FLOOR + 2,975 TYPE 2 TOTAL = 5,950 1ST FLOOR 2,277 2ND FLOOR + 2,277 TYPE 3 TOTAL = 4,554 1ST FLOOR 2,608 2ND FLOOR + 2,608 TYPE 4 TOTAL = 5,216 TOTAL UNIT BLDGS = 32,466 SO FT MANAGERS BUILDING = 1,458 SO FT (NIC) 48 (E) CAR SPAC RECEIVED CITY OF TUKWILA MAR 0 3 2014 PERMIT CENTER 0‘411{��} �QPRKING 1U77 City of Tukwila Department of Community Development 1/5/2015 MEGAN BEAUCHESNE 700 ANDOVER PARK W, SUITE C TUKWILA, WA 98188 RE: Permit No. D14-0069 RIVERTON APARTMENTS - BLDG A 14461 41 AVE S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/8/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/8/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 04/4 er Marshall t Technician File No: D14-0069 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development March 13, 2014 MEGAN BEAUCHESNE 700 ANDOVER PARK W, SUITE C TUKWILA, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D14-0069 RIVERTON APARTMENTS - BLDG A - 14461 41 AVE S Dear MEGAN BEAUCHESNE, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. (BUILDING REVIEW NOTES) 1. Each of the large rolls of plans contains all buildings work scope and details. This makes for a burdensome situation for plan review as well as inspectors in the field doing the inspections where we are required to thumb through the unrelated sheets to find relative details for the one building being reviewed and inspected. Provide plan sets that are specific for each individual building and separate from the other unrelated buildings, with only the information that pertains to that separate building being inspected and reviewed. 2. In addition to item 1, mechanical, plumbing, and electrical shall require separate permits as necessary for each building. Remove those sheets as well from the building permit sets to be used for the separate related permits with only those drawings and details for each separate relative building. 3. The permit center will allow the current permit sets submitted to be separated out, as requested above, by the applicant or applicants' agent. PLANNING DEPARTMENT: Brandon Miles at 206-431-3684 if you have questions regarding these comments. • Sheet C1.1 shows two trees being removed. These trees are part of the required landscaping for the site. Indicate why the trees need to be removed. If the trees cannot be retained, provide a site plan indicating that the site meets the City's landscaping code requirements. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, -e-3;),,c,fisp ''..---.‘i.. Bill Rambo Permit Technician File No. D14-0069 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0069 DATE: 03/27/14 PROJECT NAME: RIVERTON APARTMENTS - BLDG A SITE ADDRESS: 14461 41 AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Cal,jce0io1-I1I Planning Division 18 Permit Coordinator IN PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/01/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/29/14 Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zo ing Issues) Notation: C � C "\' M.\ 4-c1(171Ar. '?11)t •\ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0069 DATE: 03/03/14 PROJECT NAME: RIVERTON APARTMENTS - BLDG A SITE ADDRESS: 1446141 AVE S X Original Plan Submittal Response to Correction Letter #, Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: co�� Building Division DRY N� De' Public Works A-w\ Ay/1- Fire Prevention Structural NV 0; A.iej Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/06/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 04/03/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: ` \ " 1 Departments issued corrections: Bldg Fire ❑ Ping' PW ❑ Staff Initials: 12/ 18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: '/2-1) I —I ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 Plan Check/Permit Number: D 14-0069 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Riverton Apartments — Bldg. A Project Address: 14461 41 Ave S /� p� Sy7 Contact Person: Mega OM 00/► i one Number: �0�22 J • 44 • 27D Summary of Revision: ReriTved 60.1 mi tATIO & I p&c3 G and At bniat a. t cuWd sca P plan . RECEIVED CITY OF TUKWILA MAR 2 7 2014 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision L Received at the City of Tukwila Permit Center by: Entered in TRAKiT on 3� 2-7` 1 \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: CE&CINC Page 1 of 5 inWashington State Department of Labor & Industries CE&CINC Owner or tradesperson WARTER, GREGG D Principals WARTER, GREGG D, PRESIDENT BARNES, DARRELL A, VICE PRESIDENT WARTER, GEORGE L, TREASURER (End: 12/01/2001) Doing business as CE&CINC WA UBI No. 278 046 324 3221 CENTER ST TACOMA, WA 98409 253-572-5122 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CEC****346L7 Effective — expiration 06/27/1966— 09/30/2014 Bond Travelers Cas and Surety Co of America Bond account no. 105950720 $12,000.00 Received by L&I Effective date 10/07/2013 09/30/2013 Expiration date Until Canceled Bond history Insurance Colony Ins Co Policy no. 103 GL 0001255-00 $1,000,000.00 Received by L&I Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=278046324&LIC=CEC****346L7&SAW= 08/05/2014