Loading...
HomeMy WebLinkAboutPermit D14-0073 - RIVERTON APARTMENTS - BUILDING C EXTERIORRIVELRTO N APARTMENTS BLDG C 14448 41 AVE S D14-0073 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto:/,/www.TukwilaWA.aov 0040000240 14448 41 AVE S 6 DEVELOPMENT PERMIT Project Name: RIVERTON APARTMENTS - BLDG C Permit Number: D14-0073 Issue Date: 8/5/2014 Permit Expires On: 2/1/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 MEGAN BEAUCHESNE 700 ANDOVER PARK W, SUITE C , TUKWILA, WA, 98188 CE&CINC 3221 CENTER ST ,, TACOMA, WA, 98409 CEC****346L7 KING COUNTY HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 Phone: (206) 574-1219 Phone: Expiration Date: 9/30/2014 DESCRIPTION OF WORK: BUILDING C: 14448, 14450, 14452, 14454, 14456, 14458: 1 OF 7 BUILDINGS. PROVIDE EXTERIOR UPGRADES TO SIX (6) TWO-STORY APARTMENT BUILDINGS AND ONE(1) ONE-STORY MANAGEMENT BUILDING. UPGRADES INCLUDE BUT ARE NOT LIMITED TO : - REPLACE (E) SIDING, MOISTURE BARRIER, FLASHING AND TRIM - REPLACE (E) MANSARD ROOFING WITH NEW GABLE OVER -FRAMED ROOF ON TYPE 1 BUILDING (A, C & F) - REPLACE (E) EXTERIOR DOORS AND WINDOWS - CONSTRUCT ENTRY CANOPIES - DEMOLISH AND REPLACE (E) WOOD DECKS AND GUARDRAILS. Project Valuation: $75,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $2,126.52 Occupancy per IBC: R-2 Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 International Fuel Gas Code: 2012 International Residential Code Edition: 2012 WA Cities Electrical Code: 2012 International Mechanical Code Edition: 2012 WA State Energy Code: 2012 Uniform Plumbing Code Edition: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature. Date: 01[0-1' 1 I hearby certify that I have read and exami • d this permit and know the same to be true and correct. All provisions of law and ordinances go rnin: this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date:8/ s--//ci This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 9: All wood to remain in placed concrete shall be treated wood. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 14: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0201 FOOTING 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0401 ROOF SHEATHING 0603 ROOF/CEILING INSUL 4037 SI-CAST-IN-PLACE 4000 SI-CONCRETE CONST 4043 SI-E.I.F.S 4046 SI-EPDXY/EXP CONC 4032 SI-WOOD CONST 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. b t 4-- 0673 3 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 0040000240 4044 South 146th Street; Tukwila,WA 98168 Suite Number: Bldg. C Floor: 2 King County Housing Authority New Tenant: ❑ Yes J..No (Building C: 14448, 14450, 14452, 14454, 14456, & 14458) PROPERTY OWNER Name: King County Housing Authority Address: 700 Andover Park West, Suite C City: Seattle State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Megan Beauchesne Address: 700 Andover Park West, Suite C city: Seattle State: WA zip: 98188 Phone: (206) 574-1219 Fax: Email: meganb@kcha.org GENERAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: ARCHITECT OF RECORD Company Name: ORB Architects Architect Name: Geoff E. Anderson, AIA Address: 350 South 38th Court, Suite 210 City: Renton State: WA Zip: 98055 Phone: (425) 226-3522 Fax: (425) 226-9115 Email: geoffa@orbarchitects.com ENGINEER OF RECORD Company Name: PCS Structural Solutions Engineer Name: Rick Oehmcke, S.E. Address: 811 First Avenue, Suite 620 City: Seattle State: WA Zip: 98104 Phone: (206) 292-5076 Fax: Email: ROehmcke@pcs-structural.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW.'19.27.095) Name: King County Housing Authority Address: 600 Andover Park W. City: Seattle State: WA zip: 98188 H:Wpplications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION— 206-431-3670 Valuation of Project (contractor's bid price): $ 75,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Bldg. C: 14448, 14450, 14452, 14454, 14456, 14458; 1 of 7 Buildings. Provide Exterior upgrades to six(6) two-story apartment buildings and one(1) one-story management building. Upgrades include but are not limited to: - Replace (E) siding, moisture barrier, flashing and trite - Replace (E) mansard roofing with new gable over -framed roof on Type 1 buildings (A, C & F) - Replace (E) exterior doors and windows Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1StFloor 2,791 0 0 0 V-B R2 2"d Floor 2,791 3rd Floor 0 Floors thru 0 Basement 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 392,868 Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 48 Compact: Handicap: 4 Will there be a change in use? ❑ Yes 0 No If "yes'", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 1 No If "yes', attach list of materials and storage locations on a separate 8-1 '2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. El:AApplications:Forts-Applications On Line '201 I Applications 'Remit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. g074ST:ILDIN Signature: Si nature: � ' I��(j/► Date: 03/03/2014 Print Name: ���t� ��� �� �� Day Telephone: (206) 574-1219 Mailing Address: 700 Andover Park W. Seattle WA 98188 City State Zip H:Wpplications\Forms-Applications On Line\2011 Applications\Perrnit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 .11 Scope of Work (please provide detailed information): N/A Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Septic System: O On -site Septic System — For on- e septic system, provide 2 copies of a current septic design app 0 .. Highline ❑...Valley View ❑ .. Renton ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Submitted with Application (mark b t s which apply): 0 ...Civil Plans (Maximum Paper Siz 22" x 34") 0 ...Technical Information Report (Storm . inage) ❑ .. Geotechnical Re 0 ...Bond ❑ .. Insurance ■ .. Easement(s) ❑ .. Maintenance Proposed Activities (mark boxes that apply): O ...Right-of-way Use - Nonprofit for less than 72 ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards by King County Health Department. ❑...Traffic Impact Analysis ment(s) ❑ ...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ .. Ri • f-way Use - Profit for less than 72 hours -of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. AbanSepti* ank ❑ ...Cap or Remove Utilities ❑ .. C ut 0 ...Frontage Improvements ❑ .. % ,ement Cut ❑ ...Traffic Control ■ • oped Fire Line ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Wa ❑ ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size .. WO # 0 ...Water Only Meter Size WO # ❑ ...Sewer Main Extension ....Public 0 Private ❑ ❑ ...Water Main Extension... Public 0 Private 0 FINANCE INFORMATI ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding Deduct Water Meter Size Fire Line Size at Prop- Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthl Servic- •i1lin to: Name: Day Telephone: Mailing r ress: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Applications \Forms -Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 DESCRIPTIONS ACCOUNT QUANTITY PAID Permit-TRAK D14-0068 Add ss: 14442 41,.1 n: 0040000244 $7,394.90 $1,036.55 DEVELOPMENT $987.40 PERMIT FEE R000.322.100.00.00 $982.90 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $49.15 TECHNOLOGY FEE R000.322.900.04.00 $49.15 n: 0040000 DEVELOPMENT 1,315.16 $1,252.75 PERMIT FEE R000.322.100.00.00 $1,248.25 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $62.41 TECHNOLOGY FEE R000.322.900.04.00 $62.41 D14-0071 Address: 14438 41 AVE S Apn: 00400002 DEVELOPMENT. $987.4 PERMIT FEE R000.322.100.00.00 $982.90 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $49.15 TECHNOLOGY FEE R000.322.900.04.00 $49.15 72 Address: 1446041AVE' 7 Rpn:.0040000240 $1,315.1 DEVELOPMENT $1,252.75 PERMIT FEE R000.322.100.00.00 WASHINGTON STATE SURCHARGE B640.237.114 TECHNOLOGY FEE $1,248.25 $4.50 $62.41 TECHNOLOGY FEE R000.322.900.04.00 $62.41 D14-0073 Address:1444 41 AYE.$ 8 : Apn: 0040000240 $1,315.16 DEVELOPMENT $1,252.75 PERMIT FEE R000.322.100.00.00 WASHINGTON STATE SURCHARGE B640.237.114 TECHNOLOGY FEE $1,248.25 $4.50 $62.41 TECHNOLOGY FEE R000.322.900.04.00 $62.41 Date Paid: Friday, April 25, 2014 Paid By: KING COUNTY HOUSING AUTHORITY Pay Method: CHECK 241154 Printed: Friday, April 25, 2014 2:55 PM 1 of 2 CirMSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitT RAK ACCOUNT , e QUANTITY PAID $7a� 4.9 D14-0074 Address: 14440 41AVE S 4 Apn: 0040000240 $1,376.32 DEVELOPMENT $584.80 PERMIT FEE R000.322.100.00.00 $580.30 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 PUBUC WORKS $750.00 BASE APPLICATION FEE R000.322.100.00.00 $250.00 PERMIT ISSUANCE/INSPECTION FEE R000.342.400.00.00 $250.00 CONSTRUCTION PLAN REVIEW R000.345.830.00.00 $250.00 TECHNOLOGY FEE $41.52 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1935 R000.322.900.04.00 $41.52 $7,394.90 Date Paid: Friday, April 25, 2014 Paid By: KING COUNTY HOUSING AUTHORITY Pay Method: CHECK 241154 Printed: Friday, April 25, 2014 2:55 PM 2 of 2 CRWYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $811.36 D14-0073 Address: 14448 41 AVE 5 n: 0040000240 $811.36 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1366 R000.345.830.00.00 $811.36 $811.36 Date Paid: Monday, March 03, 2014 Paid By: KC HOUSING AUTHORITY Pay Method: CHECK 239589 Printed: Monday, March 03, 2014 3:55 PM 1 of 1 CraWSYSTEMS INSPECTION RECORD Retain a copy with permit IN ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pi'1-0073 twit: T P —"e V r -Ce Type of ins ection:: f kg I Address: /ti[Jrefvef0,#. Date Called: Special ins ructions: �Cd C 441 JRequester: Date Wanted: s`11-rs a.m. p.m. Phone No: Approved per applicable codes. Corrections required prior to approval. OII+IMENTS: (cr kLqg Inspector: Oate3` y ( REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Btvd., Suite 100. Galt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER Div!- DU7)Q( Qc7)ir11)04 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Proje , V 0 4011 ( aa. 4-t- Type of Inspection: AMC., M/Seec ? poi' Address: i I Suite #: / (i cf 7-0 / Lai / it `/ `iZ Contact Person: k fr1 i Special Instructions: / Wile i 1l 1l60 c ( il& / Vi S Phone No.: s 3fApproved per applicable codes. Corrections required prior to approval. COMMENTS: cSt (_ oo(09 - &ov.e. ;(c ( c- \ )A (NS t, E )p?�Z (Y1 / "4 iv4v -�v mn / f fir' _ r ��-c� �� ti ti� - a�7 Z —' SA-r 3, . C `c)iq- 00`7; — Stevv,sL i3t,tt .`k- bo b -- c� -3c,, ( �. �- � pig- a o 1 \ - --- SA-1-k , e b L l y-r to-)o 5 frcv- r. ki(s,-1 F - &Wilt/7 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: r`a� Date: 2/Z 0 C Hrs.: ? . S` $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 aTi ��'aZl & ASSOCIATFSINc_ GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION , February 12, 2015 City of Tukwila Attn: Bldg Dept 6200 Southcenter Blvd. Tukwila, WA 98188 RE: Final Letter Riverton Apartments 14440 41 sc Ave S. Tukwila, WA 98168 To Whom It May Concern: KA No. 066-14219 Permit No. D14-0069 D14-0072 D 14-0073 D14-0068 D14-0071 D14-0070 D14-0074 In accordance with your request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: • Reinforcing Steel • Diaphragm Nailing • Cast in Place Concrete • Proprietary Anchors • Lateral Framing To the best of our knowledge, all work which has been tested and/or inspected has been found to be in general accordance with the approved plans and specifications, engineering revisions, and Chapter 17 of the 2012 International Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939-2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC William B Throne Operations Manager Puyallup CC: King County Housing Authority With Offices Serving The Western United States 922 — Valley Avenue NW Suite 101 • Puyallup, WA 98371 • (253) 939-2500 • Fax: (253) 939-2556 t. • CERTIFICATE OF INSULAVI iON DWELLING INFORMATION ' i.V.QApn . CONTRACTOR INFORMATION ADDRESS OF RESIDENCE: NIALVA 1J1 FAO- & 11.V.Wt iat'LW- 9$)14 DATE INSULATION WAS INSTALLED: i S i - NAME: ARROW INSULATION, INC. ADDRESS: PO BOX 2176 Mount Vernon, WA 98273 _ 1 ,- .' . D5 — WORK Area Insulated /Area Identifier (insert ".rnspacNle" info in space provided) Square Footage Existing R Value Added R Value Final R Value Type of insulation & Method of Installation (Standard or Dense Pack) Depth S of Bags Attic - Area 1 7_ p 0 12--L9 CitaL ince ' ?lent 114.19* /07- Attic - Area 2 Attic -Area 3 _ Floor - Area 1 12 —0 Q--%p ,. ..bt,iI a SS?,' 9,5* In y �. /Z j Floor - Area 2 en i V / _..-�-u Z- 0 ,�L e 12-32 � ' PAC le- Uil ►t6c-e. Floor - Area 3 _ Wall - Area 1 Wall - Areal Wall - Area 3 Other (13/ "T" 0 tk 4,.--k1 C-v.is- d 35 h Revised .3 2/21 I, r7 ULl CiISC.O (print name), certify that this residence Weatherlratlan Assistance Program, was Insulated as administered In con nce with al applicable codes, standards, by the S to of ashington. regulations, and specifications of the Low -Income AUTHORIZED SIGNATURE DATE CtRTIFICATE OF INSULA"I ION DWELLING INFORMATION Vpi/.}ryl, 01`5 CONTRACTOR INFORMATION ADDRESS OF RESIDENCE: WIN g LI19 *CS • '"(Tito i i A.L WA- Q 7 i4$ DATE INSULATION WAS INSTALLED: 1101 i i.q NAME: ARROW INSULATION, INC. ADDRESS: PO BOX 2176 Mount Vernon, WA 98273 1$77-658-WARM Area insulated / Area IdentMer (mart •area spacifk• Info in space provided) Square Footage Exlsdng R Value Added R Value Final R Value Type of insulation & Method of Installation (Standard or Dense Pack) Depth N of Bags Attic - Area 1 _ _ Attic - Area 2 Attic - Area 3 �—_, Floor - Area 1 Floor -Area 2 _ Floor - Area 3 Wall - Area 1 23C2-I ilIi� 1 2-3 .-fb 12 -11 �t [►�G- Cp ADS, 5 ""'" Wall -Area 2 '�.�rnnS 2_ �--6 �L"�� fin di--IJ 1� `f,`I � ` Wall - Area 3 Q �/ 12 . -0 - f OM; 11. J Other ZI 0 n� 'fir b T LZS`' t. b _ 0 (print name), certify that this residence was insulated in conformance with all applicable codes, standards, regulations, specifications of the Low -Income Weathedzatlon Assistance Program, as administered by the State of Washington. sh MINNINNIII AU-MORIZED SIGNATURE DATE Revised 2/21 RIVERTON APARTMENTS - TUKWILA, WASHINGTON ALE COPY REVIE CODE COMP4J4ANCH APPROVED APR 0 8 2014 City of Tukwila BUILDING DIV;I , VICINITY M NTS w ::• a FyY.tvr T)4q >.16 tibiae; ... tlE,m1ec. Lo.� a b l4=-"bD 7 3 LEGAL DESCRIPTION PARCEL NUMBER 0040000240 4; 14436. 144 144- 14448,,,14450,14436.I4454,144' 14458, 14460, 14462. 14464. 144E 466.. 14467, 14469, & 144 / 1 41STAVE S -ADAMS HOME TRS LESS S 10 FT FOR ST PARCEL NUMBER 0040000244 IIINIIINIMIIP14442, 1444 & 14446 41ST AVE S -ADAMS HOME TRS E 1/2 S 10 FT FOR ST PARCEL NUMBER 0040000197 T4420, 14422, 14424, 14426, & 14428 41ST AVE S - ADAMS HOME TRS LOT 2 OF AMENDED TUKWILA SP #L06-091 RE( 20090219900002 SD SP DAF - E 3 FT OF LOT 15 TGW LOT 16 BLK 2 C SD PLAT PROJECT DESCRIPTION PROVIDE REPLACEMENT OF EXISTING CAST IRON SANITARY SEWER PIPING, FITTINGS, AND ALL APPURTENANCES ACCESSIBLE WITHIN THE CRAWLSPACES AND EXTERIOR OF THE BUILDINGS. ALL INTERIOR FIXTURES SHALL REMAIN AND ONLY REPAIRED ON A CASE BY CASE BASIS COORDINATED WITH THE OWNER/ENGINEER REPRESENTATIVE. PROJECT DATA 30 UNIT APARTMENT COMPLEX 14440 41st Ave. South Tukwila, VWA 98168 6 WOOD FRAME BUILDINGS 6 - 2 STORY RESIDENTIAL BUILDINGS 1 - 1 MANAGEMENT BUILDING (NIC) RD-3600 - ZONE GROUP R2 OCCUPANCY TYPE V - B CONSTRUCTION FIRE ZONE 3 TOTAL SITE AREA = 392,868 SQ FT OR 9.019 ACRES TOTAL (E) FLOOR AREAS: BLDG "A" "C" & "F" (TYPE 1) 1ST FLOOR 2,791 2ND FLOOR +2,791 SUBTOTAL = 5,582 TYPE 1 TOTAL = 16,746 BLDG "B" 1ST FLOOR 2,975 (TYPE 2) 2ND FLOOR + 2,975 TYPE 2 TOTAL = 5,950 BLDG "D" 1ST FLOOR 2,277 (TYPE 3) 2ND FLOOR + 2,277 BLDG "E" (TYPE 4) TYPE 3 TOTAL = 4,554 1ST FLOOR 2,608 2ND FLOOR +2,608 TYPE 4 TOTAL = 5,216 TOTAL UNIT BLDGS = 32,466 SQ FT "G" MANAGERS BUILDING = 1,458 SO FT (NIC) `U�^��LJ BARKING RECEIVED 48(E)CARSPAC '"1111` CITY OF TUKWILA MAR 0 3 2014 PERMIT CENTER City of Tukwila Department of Community Development 1/5/2015 MEGAN BEAUCHESNE 700 ANDOVER PARK W, SUITE C TUKWILA, WA 98188 RE: Permit No. D14-0073 RIVERTON APARTMENTS - BLDG C 14448 41 AVE S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/1/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/1/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, CAACJA er Marshall it Technician File No: D14-0073 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development March 13, 2014 MEGAN BEAUCHESNE 700 ANDOVER PARK W, SUITE C TUKWILA, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D14-0073 RIVERTON APARTMENTS - BLDG C - 14448 41 AVE S Dear MEGAN BEAUCHESNE, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. (BUILDING REVIEW NOTES) 1. Each of the large rolls of plans contains all buildings work scope and details. This makes for a burdensome situation for plan review as well as inspectors in the field doing the inspections where we are required to thumb through the unrelated sheets to find relative details for the one building being reviewed and inspected. Provide plan sets that are specific for each individual building and separate from the other unrelated buildings, with only the information that pertains to that separate building being inspected and reviewed. 2. In addition to item 1, mechanical, plumbing, and electrical shall require separate permits as necessary for each building. Remove those sheets as well from the building permit sets to be used for the separate related permits with only those drawings and details for each separate relative building. 3. The permit center will allow the current permit sets submitted to be separated out, as requested above, by the applicant or applicants' agent. PLANNING DEPARTMENT: Brandon Miles at 206-431-3684 if you have questions regarding these comments. • Sheet C1.1 shows two trees being removed. These trees are part of the required landscaping for the site. Indicate why the trees need to be removed. If the trees cannot be retained, provide a site plan indicating that the site meets the City's landscaping code requirements. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, 1>i.0 Bill Rambo Permit Technician File No. D14-0073 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0073 DATE: 03/27/14 PROJECT NAME: RIVERTON APARTMENTS - BLDG C SITE ADDRESS: 14448 41 AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Alfj� 6419,7(1(1 Building Division mg Public Works Fire Prevention Structural El Planning Division 111 Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/01/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: DUE DATE: 04/29/14 tgr jcldij(\A- evki c,lmii( PDI.I REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0073 DATE: 03/03/14 PROJECT NAME: RIVERTON APARTMENTS - BLDG C SITE ADDRESS: 14448 41 AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division sig 63s Public Works Fire Prevention Structural n Val CMvY O41 Planning Division Permit Coordinator 111 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/06/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 04/03/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: "S-13 19 Departments issued corrections: Bldg Fire ❑ Ping PW ❑ Staff Initials: ",` 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: IT-1114 Plan Check/Permit Number: D 14-0073 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Riverton Apartments — Bldg. C Project Address: 14448 41 Ave S �/�p Contact Person: veg a h U (me Number: 25'3• 4t 52 70 Summary of Revision: RECEIVED UKWILA MAR 27 2014 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of rexisign n.- Received at the City of Tukwila Permit Center by: IQ —Entered in TRAKiT on 3 )-7 - ( \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: CE&CINC Page 1 of 5 ciiill Washington State Department of Labor & Industries CE&CINC Owner or tradesperson WARTER, GREGG D Principals WARTER, GREGG D, PRESIDENT BARNES, DARRELL A, VICE PRESIDENT WARTER, GEORGE L, TREASURER (End: 12/01/2001) Doing business as CE&CINC WA UBI No. 278 046 324 3221 CENTER ST TACOMA, WA 98409 253-572-5122 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CEC****346L7 Effective — expiration 06/27/1966— 09/30/2014 Bond Travelers Cas and Surety Co of America Bond account no. 105960720 $12,000.00 Received by L&I Effective date 10/07/2013 09/30/2013 Expiration date Until Canceled Bond history Insurance Colony Ins Co Policy no. 103 GL 0001255-00 $1,000,000.00 Received by L&I Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=278046324&LIC=CEC****346L7&SAW= 08/05/2014