HomeMy WebLinkAboutPermit D14-0082 - GAMEFLY - SERVER ROOMGAMEFLY
12860 INTERURBAN AVE S
D14-0082
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.eov
DEVELOPMENT PERMIT
2716000010 Permit Number: D14-0082
12860 INTERURBAN AVE S BLDG 1 Issue Date: 5/5/2014
Permit Expires On: 11/1/2014
Project Name: GAMEFLY
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
EPROPERTY TAX INC DEPT #207
PO BOX 4900 , SCOTTSDALE, WA,
85261
DAVID KEHLE, ARCHITECT
1913 BONAIR DR SW , SEATTLE, WA,
98116
Phone: (206) 433-8997
BOYCE CONSTRUCTION Phone: (206) 264-8085
270 S HANFORD ST #109 SEATTLE,
WA, 98134
BOYCECI066QQ Expiration Date: 1/21/2016
FUNDED BY CBRE
DESCRIPTION OF WORK:
REMOVE ONE EXISTING OFFICE AND INSTALL NEW SERVER ROOM WITHIN WAREHOUSE WITH GYPSOM BOARD
CEILING.
Project Valuation: $9,000.00
Type of Fire Protection: Sprinklers: YES
Fire Alarm:
Fees Collected: $457.90
Type of Construction: VB Occupancy per IBC: B
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
Permit Center Authorized Signature:
I hearby certify that I have read and
Date:
ami ed this permit and know the same to be true and correct. All
provisions of law and ordinances gove in: this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
4¢m-r ,1_/ At 4 Sc-
Date: Sj 37 2o/!�
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
17: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all
purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC
906.3) (NFPA 10, 3-2.1)
5: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards
is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All
Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or Tess. (IFC
906.3) (NFPA 10, 3-2.1)
1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding
40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor.
Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed
so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and
the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7
and IFC 906.9)
2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and
immediately available for use. These locations shall be along normal paths of travel, unless the fire code
official determines that the hazard posed indicates the need for placement away from normal paths of
travel. (IFC 906.5)
3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely
attached that indicates the month and year that the inspection was performed and shall identify the
company or person performing the service. Every six years stored pressure extinguishers shall be emptied
and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of
the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire
extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4)
6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge
or effort. (IFC 1008.1.8.3 subsection 2.2)
7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant space. (IFC Chapter 10)
8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by
Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of
the wrist to operate. (IFC 1008.1.8.1)
10: Aisles leading to required exits shall be provided from all portions of the building and the required width
of the aisles shall be unobstructed. (IFC 1013.4)
11: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than 50 heads shall have the written approval of
Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the
Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. (City Ordinance No. 2327).
12: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open
grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3)
14: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may
require relocating and/or adding sprinkler heads. (IFC 901.4)
16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may
require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328)
15: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2328) (IFC 104.2)
18: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed
that set forth in Table No. 803.5 of the International Building Code.
13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City
Ordinances #2327 and #2328)
19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not
imply approval of such condition or violation.
20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire
Prevention Bureau at (206)575-4407.
21: ***BUILDING PERMIT CONDITIONS***
22: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
23: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
24: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
25: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage
over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic
events. The design and calculations for the anchorage or bracing shall be prepared by a registered
professional engineer licensed in the State of Washington. Periodic special inspection is required during
anchorage of storage racks 8 feet or greater in height.
26: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
27: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
28: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
29: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
30: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE FINAL
0409 FRAMING
0502 LATH & GYPSUM
0603 ROOF/CEILING INSUL
0601 WALL INSULATION
CITY OF TUCK 4
Community Develop$ent Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http:/lwww.TukwilaWA.gov
Building Pe. A No. p
—012
Project No. � 1f
Date Application Accepted:
Date Application Expires: 01
or of we use onl
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 2.1 j%t • Col -101
Site Address: Z 7(Pb iWttazue 661J i.Ve Gib
Tenant Name: AM
PROPERTY OWNER
Name: yo lJ
�`�b/1w54-10
Address:
VW �uezip,Oulu Z
City:
State • Zip:4b3z.
CONTACT PERSON — person receiving all project
communication
Name: av ii9 Whe
Address: I&l Iu Wuie Dm/
City4urtae State Zip
11ts
Phone: uu .435 ,e,epil,Fax 14,btep`
Email:A.611adKielie arch,C v
GENERAL CONTRACTOR INFORMATION
Company Name: la)
Address:
City:
State:
Zip:
Phone:
Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Suite Number: "'"" Floor: t
New Tenant: IA Yes Q.. No
ARCHITECT OF RECORD
Company Name: I4M ? "E Yet `
��
�Architect Name: &the
Address: rim, 1s�. �
G�1r
City: State:w
Zip:U1 Le
Phone: 06433.4 erv} Fax: ifrk
435(01
Email: et lull le Q d rjelikoes.ebill1
ENGINEER OF RECORD
Company Name: giAt
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater perRCW 19.27.095)
Name: ftT Nave*,es4L 15M
Address:
City: State: Zip:
H:1AppliationsFFonns-Application On Line12012 Applicationl\Permit Application Revised - 2-7-12.docx
Revised: February 2012
bh
Page 1 of 4
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ -1 O'
Existing Building Valuation: $ Z. °b tau.
Describe the scope of work (please provide detailed information):
&move� ale. t1%GC� t4� . otta - Limy ie1�¢ Dort turbot.' 442€
u1' N Il—r geeVG wdq
Will there be new rack storage? ❑ ....Yes 4..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of ; Type of
Construction per i Occupancy per
IBC 1 IBC
1" Floor
I1 Viz-
et;.
_
M.N.,et
‘4;'
d
�
2"d Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: LW [Q41t4 QtMIkir4 Compact: Handi+ :
Will there be a change in use? ❑ Yes No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers 0 Automatic Fire Alarm
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..,,.,,Yes . No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Srpers Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design appro. ed b. King Cotmt) Health
Department.
❑ None ❑ Other t specif.
H:Wppliations\Forms-Applications On Line12012 AppliationsTermit Application Revised - 2-7-12.doac
Revised: February 2012
bh
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER • R T + RIZED AGENT:
Signature:
i
Print Name: 1n k
Mailing Address: ICU 6112 911
City
Date: e 4I3 �4-
Day Telephone: GV1G'' 37-P'1Qi" t''
State Zip
H:1Applicationswottns-Applications On Linet2012 Applieetiom\Pennit Application Revised - 2.7.12 docx
Revised: February 2012
bh
Page 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermnitTRAK
ACCOUNT
QUANTITY
PAID
$284.54
D14-0082 Address: 12860 INTERURBAN
AVE S BLDG 1 Apn: 2716000010
$284.54
DEVELOPMENT
$271.20
PERMIT FEE
R000.322.100.00.00
--1
$266.70
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$13.34
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2023
R000.322.900.04.00
$13.34
$284.54
Date Paid: Monday, May 05, 2014
Paid By: BOYCE CONSTRUCTION INC.
Pay Method: CHECK 22074
Printed: Monday, May 05, 2014 9:10 AM 1 of 1
CRWSYSTEMS
Receipt Number
DESCRIPTIONS
ACCOUNT I QUANTITY
PAID
D14-0082 Address: 12860 INTERURBAN AVE S BLDG 1 Apn: 2716000010
$173.36
DEVELOPMENT
$173.36
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R1463
R000.345.830.00.00
$173.36
$173.36
Date Paid: Thursday, March 13, 2014
Paid By: DAVID E KEHLE
Pay Method: CREDIT CARD 015326
Printed: Thursday, March 13, 2014 3:13 PM 1 of 1
INSPECTION RECORD
Retain a copy with permit
av-008-2
PERMIT NO.
CITY OF "TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431-367
Permit Inspection Request tine (206) 431-2451
Projec • Type of inspection:
::z ��ate lied:�.nstruct olons: 4 ate Wanted:
If
Itequestec l
Phone No:
Approved per applicable codes.
COMMENTS:
/141)4 Wiz,.
REIN PECTION FEE IiiUIRED. Prior to next inspection, fee must be
paid at 300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit bi g9:
PERMIT NO.
CITY OF`TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
proJejt
Egol
Type of Inspection:
JAt111Q .,(1
Address:
iZ1 Y 1-":43- cQL/u Vi5Proki
Qate Called:
Special instructions:
Date Wanted: _ t
1 5 , I L
a.ni.
P.m.
Requester:
ne N a7&o•�-•}
ved per applicable codes. o Corrections required prior to approval.
COMMENTS:
Date:} ` 1'
SPECTION FEE REQU ' ED. Prior next inspection. fee must be
id at 6300 Southcenter Ell ' ., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copywith permit l -
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Pro ar.
M Fi.
Type of spection:
'F Aik1 l �.J C
Addces �--
1. (00 ...5-r•3- �p1 t Rdl+�
Date Called:
Special Instructions: -
bat nt
3
Req ueste
Phone No:
SApproved,per applicable codes. Corrections required prior to approval.
COMMENTS:
Dom:
NSPECTION FEE RE UIRED. Pridr to next inspection. fee must be
d at 6300 SouthcenteiF Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NUMBER
1)►(1--ao82.
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project: /-,
MG F(
Type of Inspection:
Address: �
Suite #: 12.)6o
-i--N S
Contact Person),
S /
trrx5E
Special Instructions:
Phone No.:
Approved per applicable codes.
COMMENTS:
C'trSz Ah2 j7Ge
(c)f
I I Corrections required prior to approval.
2- six 4 s G-%
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:- . s,' S3
Date: 4//b /j c(
Hrs.: /. 0
n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. CaII to schedule a reinspection.
Billing Address
Attn:
Address:
City:
Word/Inspection Record Form.Doc
Company Name:
State:
6/11/10
Zip:
T.F.D. Form F.P. 113
2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 and R3
Interior Lighting Summary
LGT-SUM
2012 Washington State Energy Code Can&fance Farms for Commercial, Group R1. and > 3 story R2 and R3
Revised June 2013
Project Info
Prciectmkwess bb@"er( - •
Date 03 10 I+,
I2t IwXt IZ4.i kw*.
For Budding
Department Use
FILE COPY
-.
-
r�r tQj,t�
•
i heviz w
�. _"
Awicant Pha "ell e - -3 -f 4 -7.-
Project Description
1 Alteration
Plans Included
C.2 New Budding • Addition
•
Lighting Compliance
Path
® Lighting Power Density Calculations 0 Total Building Performance
(If Total Budding Performance then only LGT-CHK is required.)
ii..h
Interior Lighting
Compliance Option
0 Building Area Method Q Space -by -space
Method
t=VtF4l1t'FD FOR
R1
Interior Lighting System
Description
Briefly describe lighting
system type and features.
D(4.1 Ouew Dt"E4
CODE COMPLIANCE
APPROVED
MAR 20 2014
City of Tukwila
Additions and Change of Space Use (CI01.4.3 & C101.4.4)
BIJILD1NC ®!VlS=a
Li Addition area or Change of Space Use area complies with all applicable provisions as stand alone project
m Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate
compliance with all applicable provisions
Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum
allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable Ming
controls per C405.2 and commissioning of lighting controls per C405.13.
Alterations, Renovations and Repairs (C101.4.3.1)
• 60% or more
of luminaires in space replaced
Building Area Method (LTG-INT-BLD) of Space -By -Space Method (LTG-INT-SPACE) Compliance Forrn. Document maxrrr,,€rs
and proposed (including existing) lighting wattage of project scope
Provide
allowed
60% of luminaires in space replaced
Space -by -space Method (LTG-INT-SPACE) Compliance Form. Document existing total wattage in space and proposed
existing) lighting wattage of project scope
• Less than
Provide
(including
ballast replacement within existing luminaires only — existing total interior building wattage not increased
■ Lamp and/or
❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit
Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific
application controls (C405.2.3), and commissioning of lighting controls per C405.13
New or moved lighting panel
Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of
lighting controls per C405.13.
reconfigured - luminaires unchanged or moved only
all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13.
• Space is
Provide
are being made to the interior lighting and space use not changed.
■ No changes
RECEIVED
CITY OF TUKWILA
MAR 13 2014
PERMIT CENTFQ
• 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Interior Lighting Summary - Space -by -Space
LTG-INT-SPACE
2012 Washington State Energy Code Compliance Forms fr r (.rro+ atrits' r -,d > 3_sto R2 and R3
Revised June 2013
Project Info
Puled Address -- --- _,,, „—
Date 0 i )4 14, '—
tzuro utIe`u at
For Building Department Use
Applicant Name: 10 Itilie {� te-Ari l ! CL
�1 r
Maximum Allowed Lighting Wattage
Location (plan #,
room #, or ALL)
Space Type*
Allowed
Watts per ft2
gross tnfenor
Area in ft2
watts Pewee
(watts/ft2 x area)
I /-r2
Ma
a 91
t33
Ltii
Atrium** Enter Height:
Retail Display Allowance from LOT-INT-DISPLAY
• Select Table C405.5.2(2) category from drop down menu.
"For atriums, indicate height Allowed wattage for first 40 feet is 0.03 W/ft ht,
above 40 feet is 0.02 W/R ht
Provosed Lighting Wattage
Total
Area
Allowed Watts
L83
ILO
Location (plan #,
room #, or ALL)
Fixture Description
(Include exempt equipment per Note 3)
Number of
Fixtures
Watts/
Fbcture
Watts
Proposed
I / fit
ftlacCe MD Lx4- iDr riutereest
2
we
1320
Retail Display Lighting from LOT-INT-DISPLAY
Total Proposed Watts may not exceed Total Albwed Watts for Interior Lighting Total Proposed Watts
I40'
Notes:
1. For proposed Fixture Description, indicate fixtun3 type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if
induded). For track lighting list the length of the back (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts/Furture, use manufacturer's fisted maximum input wattage of the fixture (not simply the lamp wattage) and
other diteria as specified in Section C405.5.1. For fine voltage back lighting, list the greater of actual luminaire wattage or length of
track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list
the transformer rated wattage.
3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Facture blank.
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Lighting, Motor, and Transformer Permit Plans Checklist LTG-CHK
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3_ story R2 and R3 Revised June 2013
Project Address Cr
Date 05k 1,i \f 4
The following information is necessary to check a permit application for compliance with the lighting, motor, and transfomier requirements
in the 2012 Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section C405.2)
44 v.
0405.21
Manual lighting
controls
Lighting control schedule with type, locations served, 50%
lighting reduction method
�Z•
C405.2.2.1
Automatic time
switch controls
Lighting systems automatic shut-off capability - indicate
method and location served on plans. Note locations where
automatic shutoff is provided by other method (occupancy
sensor, daylight controls, etc)
Override switching
Schedule with locations served - no single override switch
exceeds an area of 5,000 SF
C405.2.2.2
Occupancy sensors
Schedule of locations served
C405.2.2.3
Daylight zones
Vertical fenestration
Primary and secondary daylight zone areas indicated on plans
Skylights
Skylight daylight zone areas indicated on plans
".405.2.2.3.:
Daylight zone
controls
Lighting control schedule with dimming method and locations
served - no single daylight control zone exceeds 2,500 SF
C405.2.3
Specific application
controls
Specific application lighting controls are independent of
general area lighting and controls for other lighting
applications
Means of egress
lighting
Lighting control schedule with method and locations served.
Note luminaires that function as both normal and egress.
Display lighting
Lighting control schedule with type and locations served
Accent lighting
Ughting control schedule with type and locations served
Hotellrntrtel guest
MOMS
Ughting control schedule with type and locations served
Supplemental task
lighting
Ughting control schedule with type and locations served
Non-exempt lighting
equipment
Lighting control schedule with type, applications served and
locations
Non-exempt lighting
equipment
Lighting control schedule with type, applications served and
locations
V
C405.2.4
Exterior lighting
controls
Ughting control schedule with type, features and location
served
INTERIOR LIGHTING
POWER (Section
C405.5)
C405 5.1
Total connected
i t ng power
Schedule with fixture types, lamps, ballasts, watts per fixture
t.•Z_
Space exceptions
Space exceptions taken noted on plans or compliance form
Lighting equipment
exceptions
Equipment exceptions taken noted on plans or compliance
form
C405.5.2
ughting power
calculations
Building Area Method
Compliance form completed —proposed wattage per building
area does not exceed maximum allowed wattage
Y
Space -By -Space
Method
Compliance form completed — total proposed wattage does
not exceed maximum allowed wattage
Will%
C405.4
Exit signs
All internally illuminated exits sign are < 5 watts per side
EXTERIOR
LIGHTING POWER (Section C405.6)
il1t
C405.6.2
Total connected
gig power
Schedule with fixture types, lamps, ballasts, watts per fixture
Exterior application
exceptions
Exterior application exceptions taken noted on plans or
compliance form
Lighting power
calculations
Compliance form completed — proposed wattage for exterior
lighting plus base site allowed does not exceed max. allowed
C405.6.1
Exterior building
grounds lighting
Schedule with fixture types, lamps, ballasts, watts per fixture;
lumens per watt for Mures > 100 watts
ELEdTRICAL POWER SYSTEMS (Sections C405.7 ,C405.9, C405.12, C409.2.1)
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3
Envelope Summary
ENV -SUM
2012 Washington State Energy Code Compliance Forms for Commercial. Groun R1 antra > stool R2 & R3
Revised June 2013
Project Info
Project Address u
Date 0313
1`, aD 'l U 0,.
For Building Depa�ent Use
FILE C , PY
- -
AggkentName. lakt tip glik,pan i
Applicant Address: IS 1(, Q '`�
Ga 9V Mons. .Q,g1'i9
Applicant Phone: 1140 teict4,.
Project Description
• New Building ❑ Addition 11 Alteration ■ Change Occupancy/Conditioning
of
Compliance Path
❑ Prescriptive a Component Performance 0 Total Building Performance
Occupancy Group
N Commercial O Group R (R-1 & > 3 story R-2 and R-3)
Climate Zone
* Climate Zone 41, 4 0 Climate Zone (tif,( See WSEC 301.1 for county list)
Vertical Fenestration and
Skylight Area Calculation
If complying via the Prescriptive path,
provide values for vertical fenestration,LI&
skylights, gross walls and roof. If
complying via the Component
Performance path, these values are auto-
filled by the ENV-UA form and cannot be
edited here.
Total Vertical Gross Exterior
Fenestration Above Grade % Vertical
(rough opening) divided by Wall Area times 100 equals Fenestration
+ X 100
Gross Exterior
Total Skylight divided by Roof Area times 100 equals % Skylight
X 100
PAC —
Maximum Prescriptive
Fenestration Area
VFenestration
Fenestration 414.
Skylights 4.
50% Floor Area in DLZ
0 More than 50% of the floor area in daylight zone per C402.3.1.1 �,) i t
s
Semi -Heated Path
and has a max. heating system
for requirements.
other conditioned spaces- provide
or Component Performance compliance
spaces shall comply with
II Project has semi -heated areas as defined per C402.1.4
• Applying wall exception to semi -heated areas
1. To be deemed semi -heated the area is heated but not cooled,
output capacity between 3.4 - 8 Btuh/ft2. Refer to C402.1.4
2. Semi -heated spaces shall be documented separately from
separate compliance forms for each conditioned area type.
3.Semi-heated spaces may comply under the Prescriptive
path.
4.Envelope elements separating semi -heated from other conditioned
thermal envelope requirements for an exterior wall.
Refrigerated Spaces
❑ Walk-in cooler 0 Walk-in freezer
0 Refrigerated Warehouse Cooler 0 Change of Occupancy/Conditioning
Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for
these areas may be combined with non -refrigerated areas in the ENV -PRESCRIPTIVE form. Refer
,,� ,R�REV EVV'E D FOR '�
;'C71}mue
Spakpftalitating
MAR 20 2014
city of Tukwila
M
or
Project includes more than one occupancy type and/or level of
compliance forms may be required. Select all that apply to scope
space conditioning. Multiple
of project:
❑ Refrigerated Space
❑ Low Energy'
and compliance forms for
X Commercial • Group R1 or>3 story R2/R3
0 Fully Conditioned 0 Semi -Heated
eetpER� story
al! thermal envelope provisions
't6)te rr��aa�� rr�b�X�ott��eequlm�d ieferbC101.5.2forexemptron.
BUILDING DIVISION
MAR 13 2014
DI�4-00�2
PERMIT CENTER
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3
Component Performance Path
ENV-UA
2012 Washington State Enerav Code Comnrinnry rnrm4 fnr r'.nmmercial. Group R1, and > 3 story R2 & R3
Revised June 2013
Protect Address 1 Z &(9. d lialzueeata LIE 3..
Date f�P
Commercial 0 GroupR R-1 & > 3 sto R-2 R 3 Clear
Occupancy Group 4 ( ry / - )
!,y
For Building DepartmentTUse
Climate Zone 0 zone 44/4 O 0 zone
Change in occupancy or space conditioning • -
Note - Proposed UA may exceed Target UA by 10% per C101.4.4 end C101.4.5
Fenestration Area as % gross exterior AG wall area 4 Max. Target: 4
Skylight Area as % gross exterior roof area 9' Max. Target: t•
50% Floor Area in DLZ 0 50" of the floor area in daylight zone per C402.3.1.1 14I4
Notes: 1: If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of aN applicable envelope
elements will be calculated by the compliance firm. Refer to sheet on the backside of the ENV-SHGC form for this calculation.
2: U-factors shell come from Appendix A, chapter C303, or calculated per approved method as specified in C402.1.2.
3: Refer to ENV-CHK worksheet for example of how to complete the rows on this form.
Building Component
Provide source of U-factor, page/plan # of assembly detail & ID
Proposed UA
U-factor x Area (A) = UA (U x Al
Target UA
U-factor x Area (A) = UA (U x A)
w
$
C4
8
R= ID:Aft
R= ID:
R= ID:
Above Deck Insulation set ace.
g
00
2
R= ID:
R= ID:
R= ID:
Metal Building set occ.
..
2
0
R=1499 ID: 0,o2 — will Give aL 'IP
R= ID:
R= ID:
0 - lb3 3451-
aoz iell 9.104
Single raft, attic, other set occ.
$'
g
u-
g
R= ID:
R= ID:
R= ID:
SteeUmetal frame set occ.
S
T
g
2
0°
R= ID:
R= ID:
R= ID:
Metal ButIding set occ.
R=Z, ID:lip.9 g-ib Imo"
R= ID:
R= ID:
D. of 233.10 1w
v.itatit ti3105 11. 22I
Wood Frame, other set occ.
i
2
R= ID:
R= ID:
R= ID:
Mass Wall set occ.
23
(2i
o
n
R- ID:
R= ill ID:
Assumed to be Mass Wall set occ.
R= / ID:
R= ID:
E
co
I
R= ID:
RiN� ID:
-- ID:
Mass Floor set occ.
'g
E
u-
R= ID:
R= ID:
R= ID:
Joist/Framing set occ.
F-factor x Perimeter = UA(U x A)
F-factor x Perimeter = UA (U x A)
',r
tin
./
us
V
1
R= O ID:
R= ID:
R= ID:
0.14" 'Z4 ly y4
0.54 'Li Ms IS
Slab -On -Grade set occ.
I
=
R= ID:
R= ID:
R= ID:
Heated Slab -On -Grade set occ.
oomo
vutiir s its
=lialue
e Page
Subtotal
Area I UA
431.1 11413
UA
4$1.1y
2012 Washington State Energy Code Compli
Building Permit Plans Checklist V-r vV ENV-CHK
2012 Washington c........ 4......r
State Enerav Code mnlre" ' -- : ' "-.,.,.. o+ �id > 3 story R2 & R3 Revised June 2013
Project Address (Zt(ao igtEemalSe4.44Etio Date o31l l
1 14.
The followin information is necessary to check a building permit application for compliance with the building envelope requirements in the -''"
Washington -State Energy Code, Commercial Provisions.
Applicability
(yes,no,na)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
SCOPE (Section
C101)
14%
C 101 5.2
Low energy spaces
Low energy (unconditioned) spaces identified on plans
C101.5.2.1
/ C402.1.4
Semi -heated spaces
p
Semi -heated s paces identified on plans
i
C402.5 I
C402.6
Walk-in and refrigerated
warehouse coolers andCooler
and freezer spaces identified on plans
C101.4.6
Mixed occupancy
Spaces with different occupancy requirements identified on plans
`..,/C101.4.4
/
C107.4.5
Change in
occupancy/ArnoExisting
building spaces undergoing change identified on plans
ENVELOPE PROVISIONS
Y
C303.1
Insulation identification
identification mark to be applied to at insulation materials
'{. 1
', i
W
C30 21..4.3 /
C40
Fenestration product ratir
Fenestration products labeled with rated U-factor, SHGC. VT, leakage rating
General installation
indicate installation method, densities and clearances to achieve intended R-value of
all insulation materials
Y
C402.2.1
Roof assembly insulation
Indicate R-value on roof sections for attics and other roofs;
Indicate clearances for attic insulation:
Indicate baffles if eave vents installed:
Indicate face stapling of faced batts
-'2
'
C402.2.3
Above/below grade wall
insulation
Indicate R-value and framing material on wall sections:
Indicate face stapling of faced batts:
Indicate above grade exterior insulation is protected,
Indicate mass of masonry walls if mass wall c.laimed
Indicate loose -fill core insulation for masonry walls as necessary
Indicate frequency of grouted cores and bond beams as necessary
_"t',.
14
_
C402.5 /
C402.6
Walk-in and refrigerated
warehouse coolers and
freezer insulation
Indicate R-values for walls, ceilings, doors and floors in sections
C402.2.7
Opaque doom (< 0%
glazing)
indicate rated U-factor (swinging) or R-value (roll-up/sliding)
( 9 g) ( W rig) on wall sections
C402.2.5
Floor over outdoor or
unconditioned space
insulation
Indicate R-value on floor sections;
indicate substantial contact with surface;
Indicate that insulation does not block airflow through foundation vents.
C402.2.6
Slab -on -grade floor
insulation
Indicate R-value on wall section or foundation detail;
Indicate slab insulation extends down vertically required distance from top;
Indicate above grade exterior insulation is protected 4
C402.2.6
Radiantly heated slab on
grade floor insulation
Indite R-value on wall section or foundation detail.
Indicate slab insulation to full slab depth and under entire slab;
Indicate above grade exterior insulation is protected
C402.2.8
Thermal radiation system
Indicate insulation of panels. U-bend/heeders & floor structure is min. R-3.5
C402.3.1
Vertical fenestration max
Provide calculation of vertical fenestration area as % of gross wall area
C402.3.1.2
Skylight maximum area
Provide calculation of skylight area as % of gross roof area
Chap 2 Def.
Daylighting zone
Provide calculation of % of overall conditioned floor area in daylight zone
"V
C402.3.3
U-factors and SHGC for
vertical fenestration,
glazed entrance doors
and skylights
Indicate U-factors and SHGC values in fenestration schedules:
Provide area -weighted calculations as necessary.
Indicate if values are NFRC or default, if default then specify frame type, glazing
layers, gapwidth, low-e coatings, gas filling
C402.3.3 t
C402.3.3.1
Permanent shading
devices
Provide projection factor calculations for North and Non -North orientations
AIR LEAKAGE
C402.4.1,2.1
Air barrier materials
indicate ASTM E2178 rated materials used to provide air barrier on plans
‘/
1
G402.4,1 1
/ C402.4,2
Air barrier construction
and sealing
Indicate location of continuous air barrier on plans,
Provide details for at joints. transitions in materials, penetrations in air barrier and note
method of sealing (caulked, gasketed, or other approved method)
-"r. i
Hulk
C402.4.3 /
C402.4.4
Fenestration, door end
access opening leakage
Indicate air leakage rating and/or method of sealing for all fenestration, doors and
access openings in schedules
y
C402.4.8
Recessed lighting
fixtures
Indicate IC rating fixtures in lighting equipment schedule;
,�
Indicate method of sealing between housing and wall or ceiling in plans
44%.
C402.4.5.1
Stairway and shaft vents
Indicate locations of all stairway and shaft vents:
Provide leakage rating of motorized dampers in equipment schedules
C402.4.5.2
Outdoor air intakes and
exhausts
Indicate locations of all outside air intakes and exhausts;
Provide leakage rating of dampers and identify whether motorized or gravity in
equipment schedules
C402.4.6
Loading dock seals
Indicate weathersaal at cargo and loading dock doors
C402,4.7
Vestibules
Indicate locations and dimensions of vestibules in plans,
For unconditioned vestibles, indicate which wall assembly (interior or exterior)
insulated to exterior wall requirements
r
C402.4.1.2.3 Air barrier building test
Indicate air barrier test method conducted in accordance with ASTM E779:
rivt-VL:
&110,\Iii_uck
3 1A. x, 4-f
'v�r ; 14,Z X
Rig
v'w IZ' x
e
vzp
,,11' ►1 ; •V1 Ltr - 0,14
rue' 4kk .1 0,0zi
D/o
' of_..'1
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D14-0082
PROJECT NAME: GAMEFLY
DATE: 03/13/2014
SITE ADDRESS: 12860 INTERURBAN AVE S
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
4-wc -)O-%Y-\
uilding Division II
ublic Wor s
AV\ 4 Ce.-1)()-t9
Fire Prevention
Structural
DNA \\J 0 99 'it tM
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 03/18/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
El
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 04/15/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials:
12/18/2013
BOYCE CONSTRUCTION INC
Page 1 of 2
0 Washington State Department of
Labor & Industries
BOYCE CONSTRUCTION INC
Owner or tradesperson
BOWELL, ROBERT
Principals
BOWELL, ROBERT
BOWELL, SHERI
Doing business as
BOYCE CONSTRUCTION INC
WA UBI No.
601 538 339
270 S HANFORD ST 109
SEATTLE, WA98134
206-264-8085
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
BOYCECI066QQ
Effective — expiration
11/18/1994— 01 /21 /2016
Bond
DEVELOPERS SURETY & INDEM CO
Bond account no.
178017C
Received by L&I
12/07/2001
Insurance
Nationwide Mutual Ins Co
Policy no.
ACPACT07524265684
Received by L&I
10/04/2013
Insurance history
Savings
$12, 000.00
Effective date
11/18/2001
$1,000,000.00
Effective date
11/18/2013
Expiration date
11/18/2014
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601538339&LIC=BOYCECI066QQ&SAW= 05/05/2014
SCOPE OF WORK
REMOVE ONE EXISTING NON BEARING OFFICE, INSTALL NEW SERVER ROOM WITHIN
WAREHOUSE WITH GYP BD CEILING.
TAX up.*
211600-0010-09
E3ULDING 4 SITE STATISTICS
BUILDING CODE: IBC 2012
ZONING: M-1
CONSTRUCTION TYPE: V-B SPRINKLERED
OCCUPANCY GROUPS: B 4 S-I,FI
ALLOWABLE BUILDING AREA: UNLIMITED, 60' YARD ON ALL SIDES,
AND FULLY SPRINKLERED
AREA OF EXISTING TENANT SPACE: 10,212 SF.
AREA OF REMODEL: APPROX. 300 SF.
LEGAL DESCRIPTION
LOT 1, GATEWAY CORPORATE CENTER, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 144 OF PLATS, PAGES 23,
24 AND 25, IN KING COUNTY, WASHINGTON; EXCEPT THAT PORTION, IF ANY, DEEDED TO THE CITY OF TUKWILA FOR
SIDEWALK BY DEED RECORDED UNDER NUMBER 9303171767;
TOGETHER WITH A NON-EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS CREATED BY INSTRUMENT RECORDED UNDER
RECORDING NUMBERS 9312222125 AND 9312222126, IN KING COUNTY, WASHINGTON.
x
VICINITY MAP
N.T.S.
., .,. ,. NO CI-IANGES TO SITE OR
' - EXTERIOR OF BUILDING
..4:
F�Aci/k
PLAN NORTH 517E PLAN
SCALE: 1" = 40'
NO CHANGES TO SITE OR
EXTERIOR OF BUILDING
No changes shah � a to the
scope
of work without prior approval of Tukwila Building Division,
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
Fz1;E COPY
Permit No.
82
Plan r^view approval is subject to errors and omissions.
ip :. 61 of construction documents does not authorize
«cation of any adopted code or ordinance. Receipt
approved Field Copy and Is acknowledged:
City Of hlkwila
BUILDING DIVISION
AREA OF WORK
SEPARATE PERMIT
REQUIRED FOR:
413 aernanIcal
I'aectrical
If"Plumbing
Ladies Piping
City of Tukwila
BUILDING DIVISION
,k%<<te
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 0 2014
City of Tukwila
BUILDING DIVISION
. RECEIVED
CITY OF TUKWILA
MAR 1 3 2014
PERMIT CENTER00
C:\Documents and Settings\Ali Users\Documents\CAQ\1987-198918704-11GAMEFLY (OLD DISTRIRI ITI=R41 19Aan►Ir+n'evcn 4 ...._
nO
co
N�OV
■
EX. RR
EX. OFFICE
ADA
EX. OPEN OFFICE
EX. STORAGE
EX. OFFICE
FLOOR PLAN: DEMO
SCALE: 1/8" = 1'-0"'
•
ANY OLD DRAINS' OR DRAIN PIPING IN
THIS AREA TO BE CAPPED AND
PLUGED.
CLEAN FLOOR, FLOOR TO
RE SEAL \
EX. RR
E SMOOTH
ir-L REMOVE EXISTING
EX. OFFICE 1 WALL FOR NEW POO
I `
EX. OPEN OFFICE
REMOVE EXISTING WALLS, DOOR AND
WINDOW, PATCH AND REPAIR AS
REQUIRED.
DEMO NOTES:
1. AT AREAS OF DEMOLITION, PATCH AND REPAIR WALLS, FLOOR AND CEILING
2. AT REMOVED WALLS, REMOVE ANY ELECTRICAL TO ABOVE CIELING IN NEUJ J-E3OXES
WITH LA1BEL OF CIRUIT AND PANEL
3. REMOVE ANY UNUSED DATA OR PHONE CAIBELING
4. REPAIR ANY DAMAGED SHEET ROCK IN OFFICE AND WAREHOUSE
5. REMOVE EXISTING FLOOR FINISHES IN OFFICE AREA AND RESTROOMS
6. REMOVE EXISTING EXTERIOR WINDOWS TWAT HAVE !BROKEN SEALS OR
ARE LEAKING. REPLACE
1. ENSURE ALL ROLL UP DOORS ARE IN GOOD WORKING CONDITION'
8. ENSURE ALL MECHANICAL, ELECTRICAL, PLUMING AND SYSTEMS
ARE IN GOOD WORKING CONDITION.
DOOR SC4EUL:
1. NEW 3'-0'X1'-0" SC WOOD DOOR (STAIN) WITH MTL JAMBS (TO MATCH EXISTING) 1 1/2 PAIR
BUTTS, CLOSER, THRESHOLD, WEATHERSTRIP, WALL STOP
El EX. 35<1' ALUMINUM STOREFRONT DOOR WITH EXIT PADDLE
E2,3,1 EX. 3'X1' SC WOOD DOOR AND MTL. JAMBS, LOCKSET
E4,5,9 EX. 3'X1' 5C WOOD DOOR AND MTL. JAM55, PRIVACY LOCK
E10,I2,15 EX. OVERHEAD DOOR
E11,13,14 EX. HOLLOW METAL DOOR AND FRAME, LOCKSET (INSIDE KNOW TURNS
FREE)
UJAI_ L TYPE
A. NEUJ 2x8 WOOD STUDS AT 24" O.C., WITH R-213 GATT INSULAtION, VAPOR BARRIER ON WARM
SIDE, 5/8" GYP D. EACH SIDE, (U-0.04) TO 11' AFF
ROOM $CkEULE
I. REPAINT ENTIRE PREMISES INCLUDING WAREHOUSE WALLS
2. IN OFICES, INSTALL NEW CAWE7 IN CARPETED AREAS WI71-I NEW RU68ER BASE
3. IN RR, INSTALL NEW SHEET VINYL WITH 6" COVED SEHNT VINYL. BASE
14CW
EX. RR
EX. ADA RR
to
r r a
EX. WAREHIOUSE
SEMI I-IEATED MAX 8 BTUH
4,119 SF a 1'500 = 9 OCC.
SINGLE EXIT, TRAVEL DISTANCE UNDER 100 LF
■ ■
2- 4" DIA HOLES TO
ABOVE INSULATION AND
BELOW CEILING.
DEDICATED 30
STANDARD OUTLE i
EX. RR
EX. OFFICE
111SFe1/100=1.1
OCC
•
EX. STORAGE
EX. OFFICE
111SFie 1/100=1.1
OCC
•
s
•
•
EX. OFFICE
491SFID1 /100 =5
OCC
s I E1
•
s
NEW SERVER RI
183SFe 1/100.1.8
OCC
EX. OFFICE
4916FD1/100s5
OCC
a a • • 1
FLOOR PLAN: NEW
SCALE: 1/8" = 1'-0"
EX. OFFICE
HEATED AND COOLED
1134 SF ' 1'100 = it OCC.
SINGLE EXIT, TRAVEL DISTANCE UNDER 100 LF
.1.
.1,
STANDARD 115 POWER OUTLET (NEMA 5-15)
DEDICATED 30 AMP 100/120 V POWER OUTLET WITH NEMA
15-30 OUTLET
PROVIDE SEPARATE COOLING FOR SERVER ROOM, GOODMAN STAND
ALONE OR APPROVED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 0 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
MAR 13 2014
0
0 0
h
efi
02
M
0
'4
coI
0
0
L!J
a
U
w
5 6
C.7
taul7
w <�
c)
0 w.4 4t4N
z �H
H
PERMIT CENTER
C:\Documents and Settings\AII Users\Documents\CAD\1987-1989\8704-1\GAMEFLY (OLD DISTRIBUTECH 12860)\CD'S\12860 GAMEFLY recover.dwg, T-1, 3/13/2014 1:56:29 PM
PROVIDE R-19 IN STUD CAVITY,
PROVIDE R-30 OVER FRAMING
//Li) 4k 1\A/,
2X6 CEILING JOISTS e 24" OL,
TOE NAIL TO STUD WALL AND TO BLOCKING WITH
I0d (MIN TUJO).
STUD WALL TYPE A
FULL THICK INSULATION
TYPICAL WALL TO SLAB
DETAIL 2/T-2
EXISTING STUD WALL VERIFY INSUALTION OR
INSTALL FULL THICK
INSULATION TO 10'AFF
g SECTION AT SERVER
SCALE: 3/4" - I'-0"
TYPICAL WALL
FRAMING
ATTACH BOTTOM
TRACK TO CONC.
FLOOR UJ/ POWDER
DRIVEN ANCHORS, HILTI
OR APPROVED 1" EMBEDMENT
AT 24" 0.C.
111,411 TO SLAB
SCALE: I-I/2" = 1'-0"
5/8" GYP. P.
ACOUSTICAL BLANKET
e SOUND WALL.
CONC. SLAB ON GRADE
CAULK GYP. BD. TO FLOOR
e ALL SOUND AND INSUL.
WALLS
SECTIOP
WOOD DOOR
HOLLOW METAL
DRY WALL FRAME
5/8" GYP. BD.
BOTH SIDES
STEEL STUDS
INTERIOR DOOR JAMB
SCALES 1 1/2' =
L
IX4 SURFACE MOUNTED 2 TUBE FLUORESCENT
FIXTURES WITH ACRYLIC WRAP AROUND (66 WATTS)
TOTAL WATTS INSTALLED 132 WATTS, ALLOWED 161 WATTS
■
•
CEILING: 2X6 WOOD J015T5 AT 24" O.C. WITH R-49 INSULATION,
VAPOR BARRIER ON WARM 5IDE, 5/8" GYP BD ON INSIDE,
NOTHING ON TOP, SIGN/GE ON SIDES TO WAREHOUSE
"NO STORAGE ABOVE" (U=0.021) SEE SECTION T-2
NORtN
GAMEFLY
EX. SUSPENDED CEILING WITH
LIGHTING NO CHANGES
MODIFY EXISTING LIGHTING AT
REMOVED OFFICE TO MATCH
BALANCE OF ROOMS SPdf=INf
03-05-06
C ATEUJ4Y CORPORATE CENTER 131.-DC . 1
12860 INTERURBAN AVE 5, LEGEND
TUKUJILA, WASHINGTON o ON -GRADE DOOR
RENTA5LE SQUARE FOOTS ®DOCK LEVEL DOOR
TOTAL AREA: 6,100 SF. R
OFFICE AREA: 1,550 S.F.+ 183 5F COMP.
fREVIEWED FOR
CODE COMPLIANCE
APPROVED
, MAR 2 0 2014
City of Tulcwilr
BUILDING DIVISy
RECEIVED
CITV OF TUE�WIL 1�,
MAR 13 23Vt
PERMIT CENTER
C:\DocumentS and Settinas\AII USersiDecumentrs1CAf]119R7-1QRA1R7(ld_41rARACCI v /no n niemi i rr�nu Anek&n.r..�.,�....,..........
M
0
CO CD
M
* N
0=. LL
0
L'A-
L!J