Loading...
HomeMy WebLinkAboutPermit D14-0090 - PERFUME PARADISE - KIOSKPERFUME PARADISE 2800 SOUThCENTER MALL K-1022 D14-0090 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 9202470010 Permit Number: D14-0090 2800 SOUTHCENTER MALL K1022 Issue Date: 4/16/2014 Permit Expires On: 10/13/2014 PERFUME PARADISE Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940, CARLSBAD, OR, 92013 GUY GIBSON 12369 N ERA RD , OREGON CITY, OR, 97049 DIRTY WORK 12369 S NEW ERA RD , OREGON CITY, OR, 97045 DIRTYW*916B1 NOT REQUIRED Phone: (503) 720-7558 Phone: (503) 720-7558 Expiration Date: 1/31/2015 DESCRIPTION OF WORK: 150 SF KIOSK Project Valuation: $1,220.00 Type of Fire Protection: Sprinklers: Fire Alarm: Fees Collected: $173.48 Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: fuv os1/41 Date: f1411(i l k / I hearby certify that I have read and -. ed this permit and know the same to be true and correct. All provisions of law and ordinances gove this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditio -. ' ed to this permit. Signature: -- ` Date: Z-/ �(►�/ /� Print Name This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: Post address on kiosk per approved Westfield standards. 4: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 5: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 6: ***BUILDING PERMIT CONDITIONS*** 7: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 8: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 9: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL CITY OF TUX LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. �L DG 'O Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: \ f?2O p Tenant Name: � I/" +���Q (PG, sa. CA S F. PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Cam y ‘ G t Address t Z t r` ,n 42tAJ .vst,s.- 2d ' City: ov.,a�t State: 0 it_ Zip: C7c)�s. C Phone503,,�o ?1 Fax: Email: c-foe,,rW �yU✓e0 -fq ciP)(. r'o..-� GENERAL CONTRACTOR INFORMATION Company Name: p; v._ ,Q / _ _ Address: ( e `3 6 ? S evl�l y,„ 19� City: o C. /►1 State Q ql..4 it Zip'705 Phone: s0 ,,< 2,0. Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: allig ` L I -cow �eNumber:_?_f 1— Floor: (; 71— New Tenant: Yes ❑ .. No ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 14 A. Address: City: State: Zip: H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 1 of 4 BUILDING PERMIT INFORMATN • 206-431-3670 Valuation of Project (contractor's bid price): $ / Existing Building Valuation: $ Describe the scope of work (please provide detailed information): tit to it a a c ic.. i i' � �� v+t1!`��% �C C-p Cis ✓' r rex- / O- ( • Will there be new rack storage? ❑ ....Yes p..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la Floor IO X / s 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes No Compact: Handicap: If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: � ,Q ❑ Sprinklers Ely► Automatic Fire Alarm 0 None If Other (specify) / ' a eve Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Appliations\Forma-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O Signature: Date: 3 -2o Print Name: G.6? 461.,f-ge 9_01 Mailing Address: Day Telephone: 3 ^ 7 70 .7 $ i a „4; atk 70 to Zip H:\Applications\Fonns-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 PUBLIC WORKS PERMIT INF( 'IATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila 0 ...Water District # 125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site sept system, provide 2 copies of a current septic design approved by g County Health Department. ❑... Highline ❑ ...Valley View ❑... Renton ❑ ...Sewer Availability Provided ❑... Renton 0... Seattle Sabjnitted with Application (mark boxes whi a Civil Plans (Maximum Paper Size — 22" x ') ❑ .. Technical Information Report (Storm Drainag. ❑... Geotechnical Report ❑ .. Bond ❑... Insurance ❑... . . ment(s) ❑... Maintenance Agreem Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for Tess than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water . Abandon Sep . Curb Cut . Paveme ut . Loope' ire Line ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑... Right-of-w. se - Profit for less than 72 hours ❑... Right -of : y Use — Potential Disturbance ork in Flood Zone Storm Drainage ❑ .. Permanent Water Meter Size (1) WO # (2) 0 .. Temporary Water Meter Size (1) " WO # (2) ❑ .. Water Only Meter Size WO # ❑ .. D ❑ .. Sewer Main Extension Pu 0 Private 0 ❑ .. Water Main Extension . is 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Lin ❑ .. Water / Sewer ❑ .. Sewage Treatment Monthly Service Billin 0... Grease Interceptor ❑ ... Channelization ❑ ... Trench Excavation 0... Utility Undergrounding O # (3) (3) ct Water Meter Size Number of Public Fire Hydrant(s) " WO# " WO# Name: Day Telephone: Mailing Address. City State Zip Water Mete of ind/Billing: Name: Day Telephone: Mailing Address: City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK I PAID $173.48 D14-0090 Address: 2800 SOUTHCENTER MALL K1022 Apn: 9202470010 $173.48 DEVELOPMENT $168.51 PERMIT FEE R000.322.100.00.00 $99.40 PLAN CHECK FEE R000.345.830.00.00 $64.61 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1538 R000.322.900.04.00 $4.97 $173.48 Date Paid: Thursday, March 20, 2014 Paid By: GUY GIBSON DBADIRTY WORK Pay Method: CHECK 1495 Printed: Thursday, March 20, 2014 10:08 AM 1 of 1 } , INSPECTION RECORD Retain a copy with permit INSP ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION D1+-od5 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3671' Permit Inspection Request Line (206) 431-2451 Pj irittl Al & are plec on: Type o e t vnsr 4 r(tat. 1r 't Add ss: Aii Date Called: Special instructions: gy..3 f / Date Wanted: i, � a.m. Requester: Phone No: sr -- Approved per applicable codes. COMMENTS: fierm zroAp inspe Dates REINSPECTION FEE REQUIIt D. F % for to next inspection, fee must be paid at 6300 Southcenter Bivd:. Suite 100. Call o schedule reinspection.' ,17 INSPECTIONRECORD Retain a copy with permit INSPECTION NUMBER OH- 0040 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: rr�-1, Pyr-610-c_ Type of Inspection: F Fi pc'. Address: 2A ou St,,, u. Suite #: k /o 2 /t.• i i Contact Person: Special Instructions: Phone No.: KApproved per applicable codes. COMMENTS: I I Corrections required prior to approve Ok__ Needs Shift Inspection: i Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupan ype: Inspector: Alin ; / / Date: (1-/ 7-i 9 Hrs.: S n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 II ay Ilona ‘IMir s ■ rens& 1tU. O117 Alan review approval is subject to ors and omissions. Approval of construction documents does not authc ri-s ths. violation of any adopted code or ordinance. Receipt of approved Reid andcor do edged: tINDLVIDO BUILDING -MOWN 1. ALL WORK SHALL CONFORM TO ALL GOVERNING CODES AND ORDINANCES. 2. CONTRACTOR SHALL APPLY FOR, OBTAIN, AND PAY FOR ALL LICENSES AND INSPECTIONS AS REQUIRED TO COMPLY WITH ALL CITY AND LOCAL CODES AND LAWS. 3. PRIOR TO COMMENCING WORK, THE CONTRACTOR, IN CONFERENCE WITH BUILDING MANAGEMENT, SHALL PREPARE A LIST OF HIS ACTIVITIES THAT WILL, IN ANY WAY AFFECT THE NORMAL OPERATIONS OF THE BUILDING AND NEIGHBORING TENANTS. PROTECTIVE MEASURES AND SCHEDULING SHALL BE ESTABLISHED TO MINIMIZE DISRUPTION OF PROJECT PROPERTY NOT RELATED TO THE PROJECT. PROVIDE THE MANAGEMENT WITH A COPY OF THE SCHEDULE AND THE DESCRIPTION OF PROTECTION. 4. THE CONTRACTOR RESPONSIBLE FOR CHECKING CONTRACT DOCUMENTS, FILED CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THE WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THE ARE ANY QUESTIONS, THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT AND BUILDING MANAGEMENT IN WRITING AND OBTAINING A CLARIFICATION FROM THE ARCHITECT AND BUILDING MANAGEMENT BEFORE PROCEEDING WITH WORKIN QUESTION OR RELATEDF WORK. REQUESTS FOR ADDITIONAL CHARGES WILL NOT BE ENTERTAINED FOR THE CONTRACTORS FAILURE TO FORESEE MEAN OF INSTALLING EQUIPMENT INTO POSITION INSIDE STRUCTURES. 5. REFERENCES TO MAKES, BRANDS, AND MODELS IS TO ESTABLISH TYPE AND QUALITY DESIRED, SUBSTITUTIONS FOR "EQUALS" WILL NOT BE ACCEPTABLE UNLESS SPECIFICALLY APPROVED BY THE ARCHITECT. 6. THE CONTRACTOR SHALL ORDER MATERIALS IN SUFFICIENT TIME FOR ORDERLY INSTALLATIONS. THE ARCHITECT WILL NOT ENTERTAIN ANY REQUESTS FOR MATERIAL SUBSTITUTIONS. IF NECESSARY, THE CONTRACTOR SHALL PROVIDE AND INSTALL TEMPORARY FINISHES OR MATERIALS. MONIES WILL BE WITHHELD PENDING THE SATISFACTORY INSTALLATION OF SPECIFIED FINISHES AND MATERIALS. 7. THE CONTRACTOR SHALL DETERMINE ALL LEAD TIMES FOR FINSH MATERIAL AT T TIME OF PRICING TO ASSURE AVAILIBILITY OF MATERIALS AS SCHEDULE REQUIRES. ANY COSTS FOR SPECIAL HANDLING OR AIR FREIGHT OF MATERIALS IN ORDER TO MEET REQUIRED DEADLINE IS THE RESPONSIBILITY OF THE CONTRACTOR. 8. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 9. ALL WALL DIMENSIONS ARE FINISHED FACE -OF -WALL, UNLESS SHOWN OR NOTED OTHERWISE 10. ALL CLEAR DIMENSIONS ARE REQUIRED TO BE EXACT WITHIN 1/8" SCALE TOLERANCE ALONG FULL HEIGHT AND WIDTH OF WALLS. 11. DIMENSIONS NOTED "V.I.F." SHALL BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. 12. NEW CONSTRUCTION SHALL MATCH EXISTING. EVERY EFFORT MUST BE MADE TO PROVIDE A SEAMLESS, LIKE -NEW SPACE; NO EVIDENCE OF PREVIOUSLY EXISTING CONSTRUCTION SHALL REMAIN. NEW CONSTRUCTION SHALL MEET FLUSH IN THE SAME PLANE WITH NO VISIBLE JOINTS SHOWING U.O.N. 13. THE CONTRACTOR SHALL COMPLETE SUBMITTALS FOR ARCHITECTS APPROVALS PRIOR TO INSTALLATION FOR THE FOLLOWING ITEMS: 1. CASEWORK HARDWARE 2. 12" X 12" PAINT BRUSH OUTS AND SAMPLES OF ALL FINISH TYPES AND COLORS. 14. SHOP DRAWINGS MUST BE SUBMITTED FOR ARCHITECT'S AND BUILDING MANAGEMENTS APPROVAL BEFORE ANY MILLWORK, CASEWORK, STRUCTURAL OR METAL FABRICATION IS BEGUN. PRIOR TO SUBMITTAL TO ARCHITECT AND BUILDING MANAGEMENT, SHOP DRAWINGS HAVE BEEN CHECKED FOR CONFORMANCE WITH CONTRACT DOCUMENTS. PERFUME PARADISE 10' x 15' PERFUME KIOSK SPACE # 9065 LEVEL 1 SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA. 98188 (206) 246-0423 GENERAL NOTES CONT'D 15. SHOP DRAWINGS ARE NOT CONSIDERED CONTRACT DOCUMENTS. THEY ARE ONLY A CONVENIENCE TO FACILITATE PROGRESS OF WORK. SHOP DRAWINGS WILL BE REVIEWED BY ARCHITECT, TENANT, AND BUILDING MANAGEMENT FOR GENERAL REQUIREMENTS. 16. UPON PROJECT COMPLETION, CLEAN AND POLISH ALL ORNAMENTAL METAL, GLASS, HARDWARE, RESILIENT FLOORING, CERAMIC TILE AND OTHER SUCH ITEMS WITH FACTORY FINISHES. REMOVE ALL DUST WITH DUST -CLOTH OR VACUUM CLEANERS. 17. PER THE LANDLORD, LOOSE ITEMS SUCH AS POP-UP ADS, PAMPHLETS, ETC. WILL NOT BE ALLOWED ON COUNTERTOPS. ANY OF THESE ACCESSORIES MUST BE BUILT INTO COUNTERTOPS OR DESIGNED WITHIN TO BE ACCEPTABLE. LANDLORD WILL INSIST THESE LOOSE ITEMS BE REMOVED. 18. PER THE LANDLORD, SHROUDS MUST BE INSTALLED AROUND ALL POS AND CASH REGISTERS TO HIDE UNSIGHTLY WIRING AND BACK SIDE OF EQUIPMENT. 19. TENANT IS TO VERIFY WITH WESTFIELD'S ON -SITE TENANT COORDINATOR THE UTILITIES AND POINT OF CONNECTION PROVIDED BY THE LANDLORD. TENANT IS RESPONSIBLE FOR FINAL CONNECTION AND EXTENSIONS TO LANDLORD'S STUB -OUT AT TENANTS EXPENSE. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 PROJECT DESCRIPTION INTERIOR TENANT IMPROVEMENT FOR A SMALL FLOATING RETAIL STATION IN A EXISTING OR NEWLY CONSTRUCTED BASE BUILDING. WORK TO INCLUDE NEW CASEWORK, NEW EQUIPMENT, AND NEW FINISHES. ELECTRICAL WORK SHALL BE FILED UNDER SEPARATE PERMIT. SIGNAGE SHALL BE DESIGN / BUILD AND FILED UNDER SEPARATE PERMIT. 1 ADDITIONAL NOTES 1. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION AND COORDINATION OF ALL ELECTRICAL AND FIRE PROTECTION WORK. THIS INCLUDES ANY APPLICABLE DRAWINGS, DETAILS, CALCULATIONS, ETC, THAT MAY BE REQUIRED TO PROPERLY EXECUTE THIS WORK. A. LOCATIONS, QUANTITIES AND CODE COMPLIANCE OF ALL NEW RECONFIGURED ELECTRICAL AND FIRE PROTECTION DEVICES ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. THE GENERAL CONTRACTOR SHALL KEEP THE ARCHITECT, TENANT, AND BUILDING MANAGEMENT ABREAST OF ALL DESIGN BUILD PROGRESS. SUBMIT COPIES PRIOR FABRICATION / INSTALLATION. SUBMIT PRINTS TO THE ARCHITECT, TENANT, AND BUILDING MANAGEMENT FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WORK. 3. SIGNAGE SHALL BE DESIGN / BUILD AND FILED UNDER SEPARATE PERMIT. POWER/COMMUNICATION NOTES 1. CONTRACTOR SHALL THOROUGHLY EXAMINE EXISTING FACILITY AND CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED, INCLUDING EXISTING ELECTRICAL SERVICE, GENERAL CONDITIONS, AND LOCATIONS OF WORK TO BE EXECUTED AS SHOWN ON THE DRAWINGS. REPORT ANY CONFLICTS TO ARCHITECT. 2. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS TO INSTALL THE ELECTRICAL A SHOWN AND AS REQUIRED FOR A COMPLETE WORKING SYSTEM. 3. ALL ELECTRICAL, FIRE PROTECTION, AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH LATEST RULES AND REGULATIONS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS, THE STATE FIRE MARSHALL, NATIONAL FIRE PROTECTION ASSOCIATION (N.F.PA), NATIONAL ELECTRIC CODE (N.E.C.), STATE AND CITY BUILDING CODES AND ANY APPLICABLE LAWS, CODES AND ORDINANCES. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 4. ALL EQUIPMENT TO BE UNDERWRITER LABORATORY (U.L.) LABELED. 5. ALL WORK AND MATERIALS TO BE GUARANTEED AGAINST FAULTY WORKMANSHIP OR DEFECTIVE MATERIAL. 6. REESTABLISHED DIRECT SERVICE TO ALL EXISTING FACILITES WHERE DISRUPTED BY THE CONTRACTOR. 7. ALL WALL ELECTRICAL RECEPTACLES SHALL BE MOUNTED 18" A.F.F. TO CENTERLINE OF RECEPTACLE COVERPLATE, MOUNTED VERTICALLY, U.O.N. 8. ALL SWITCH LOCATIONS AND ANY OTHER WALL MOUNTED CONTROL DEVICES ARE TO BE FIELD APPROVED BY ARCHITECT AND TENANT BEFORE INSTALLATION. DRAWING INDEX A0.0 NOTES/INDEX A0.1 VICINITY MAP/SITE PLAN A0.2 POWER, DATA, & LIGHTING PLAN/ SCHEDULES A1.0 3D RENDERING A2.0-A2.8 FINISH PLAN/EXTERIOR & INTERIOR ELEVATIONS A3.0-A3.2 SECTIONS, TALL & SHORT PYLON SIGN DETAILS A5.0 ELECTRICAL PLAN/CONNECTIONS DETAILS SYMBOLS NORTH ARROW CENTER LINE (DIMENSION LINE) - ELEVATION ELEVATION NUMBER SHEET NUMBER SECTION I - SECTION NUMBER SHEET NUMBER O DETAIL - DETAIL NUMBER SHEET NUMBER - ENLARGED DETAIL - DETAIL NUMBER SHEET NUMBER l l • FINISH MATERIAL ROOM NAME IW1- ROOM NUMBER 0 KEY NOTES & SHEET NOTES CEILING HGT: RFLCTD CEILING PLAN REVISION DOOR SYMBOL - HARDWARE GROUP SEE SPECS. - EQUIPMENT GROUP SEE SPECS. �j ALIGNMENT SYMBOL NOTE: SOME OF THE ABOVE SYMBOLS MAY NOT HAVE BEEN USED FOR THIS PROJECT. BUILDING DATA ADDRESS: SOUTHCENTER MALL 2800 Southcenter Mall Seattle, WA. 98188 (2006)246-0423 OCCUPANCY GROUP: M revs I.<.ME.lq,'TIIDt • FLLLY VLVI 1E813). 0.0.08120 if T015 18088 8TGIDT1NCl. TIR EI1II103 C c kDG CODE OWE WO 000E WYC 61ED atut 003441 RLM 0X0 L$6I * 6xpA toot Mut ins A ty41 1011 INTCMq..MDT• COX 11TAIT B.LZ; oxfi VMC 08440 Mq iiGMTONAL NUR =E WAN IMO CCOF, MAC S:LW mMAIFI FON STATE Meg CCM *OE ODE. OmE FPO FFO AIX {!0t 0:0* i`01aMt ti OBiiIIHs ACTT d ATE tDt Cm6 l W4001008 80888811"E 00)08 000 04 WIWE tF+. MCI= loot salmix xvk LtIE COL>4'L /OFF6FR ANPFAEFFIX MCI, PEKI N cme 9. i l6 LA 4 CN RATE ANYEEN1UME 00008 OCC45 711116 P OD OEM F E 0l;PAREYFEC i7IY e6 TLM1♦<A8.E84rrs.I181 tloD BOUR[8801 s. LEFOF !MINA NA Wu CONTACT' : CfECT TEL Pkg *mass T� :Yon414E00 OTY OF 1L ONIAP E CETARnIBR -1.IEA]PAT04 i • STAXIN 44 4.0,4480 / 1 ik -Arin NAKAMURA-BEEMAN, INC. 8520 WELLSRMD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 m �e m 1 Millillill SIDEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 • 19705 02/21/14 SCALE AS NOTED PAGE A0.0 ' J -ao`Io Pawl MACY'S THIS SIDE VICINITY MAP MALL LOCATION SITE PLAN - ACCESSIBLE OF TRAVEL NOTE: KIOSK IS MINIMUM 10' FROM NEAREST STOREFRONT; MINIMUM 20' FROM NEAREST KIOSK DOWN EAST BASICS REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 City of Tukwila BUILDING DIVISION PERFUME PARADISE REVISIONS No changes shall be made to the scope of work without prior approval of PACE # 9065 Tukwila Building Division. 10'X15' KIOSK NOTE: Revisions will require a new plan submittal and may include additional plan review fees. *KIOSK CLEARS 8 FOOT HEIGHT TO ANY AND ALL PROJECTION OF TENANT SPACES BORDERING MALL AND lilt NEAKIS L R1051C1 RADIO SHACK 15'-10"± 180 SHORT r [PYLON r GATE CHAMPS 1C' MIN�MUN 10' MINIMUM BODY SHOP L FUEGOS 0 22' PERFUME PARADISE 10'X15' KIOSK SPACE # 9065 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER + SEPARATE REQUIRED FOR: Mechanical TALL PYLON 1 Electrical CPENNEY Plumbing HIS SIDE RI Gas Piping City of Tukwila BUILDING DIVISION iy — - - - - - — NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 aw e-UQ X a o to I W 0 Ho. REVISIONS DATE., SIDEMARI( SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 JOBI 19705 GATE 02/21/14 SCALE AS NOTED PAGE A0.1 e FINISH NOTES FLOOR PLAN NOTES NOTE: 1 LIGHTING SCHEDULE FOR LIGHT FIXTURES AT CASEWORK, REFER TO LIGHTING PLAN 3/A1.0. FINISH NOTES: GENERAL FLOOR PLAN NOTES SYMBOL TYPE / LOCATION MANUFACTURER / CATALOG NO. NOTES: ITEM A 0 PYLON BACKLIT SIGNAGE & ISLAND DISPLAY CASE RI LED . -• . A. CONTRACTOR / FABRICATOR SHALL VERIFY EXISTING COLUMN TO COLUMN DIMENSION. DIMENSIONS SHOW ARE TAKEN FROM EXISTING CONTRACT DOCUMENTS. REPORT VARIATIONS THAT ARE MORE THAN t2" FROM ASSUMED DIMENSIONS AND THAT WILL HAVE CONSIDERABLE IMPACT TO THE ALIGNMENT OF CASEWORK AND REQUIRED CLEARANCES. CONTRACTOR SHALL NOT PROCEED WITH SUCH CASEWORK LAYOUT UNTIL THE BUILDING MANAGEMENT AND ARCHITECT HAVE RESOLVED SUCH CONFLICTS. B. CONTRACTOR / FABRICATOR TO VERIFY ELECTRICAL REQUIREMENTS FOR EQUIPMENT. C. FOR CASEWORK MODULAR TYPES AND SCHEDULE, SEE SHEET A3.0. 1. MATERIAL FINISHES ARE RATED CLASS A WITH FLAME SPREAD OF 25 OR LESS, AND MEETS REQUIREMENTS FOR SMOKE DEVELOPMENT FACTORS. ALL WOOD SUBSTRUCTURE TO BE FIRE RETARDANT, PRESSURE TREATED AND MEET UL TESTING STANDARDS PER 200+ IBC 402.5.1 & 402.1.0 2. THE FOLLOWING MODEL NUMBERS AND COMPONENTS LISTED ARE SHOWN AS A STANDARD OF QUALITY AND UTILITY. OTHER MANUFACTURERS OFFERING EQUIVALENT PRODUCTS WILL BE ACCEPTABLE SUBJECT TO THE REVIEW BY THE LANDLORD AND TENANTS FIELD REPRESENTATIVE. — ..-,-. • — REVIEWED FOR B I DISPLAY CASES LG SMD LED CODE COMPLIANCE APPROVED 4 4 c APR 2014 FINISH SCHEDULE D City of Tukwila BUILDING DIVISION , CODE FINISH MANUFACTURER / MODEL COLOR REMARKS ELECTRICAL LEGEND LIGHTING NOTES A BRIGHT WHITE SOLID SURFACE SAMSUNG OPAQUE WHITE AT ISLAND P.O.S. COUNTER & SHROUD B LIGHT STAINLESS CHEMETAL 927 METAL AT SMALL DISPLAY CASE C ILLUMINATED FROSTED ACRYLIC PANEL — TRANSLUCENT WHITE AT SHOWCASE AND DISPLAY TOP $ SWITCH Ar-1— LETTER DENOTES FIXTURE 1. GENERAL LIGHTING ON MASTER GENERAL LIGHTING STATION. D 3/8" CLEAR TEMPERED GLASS — TRANSPARENT AT KIOSK SHOWCASES E FIRE -RATED P.B. W/ WHITE LINER — OPAQUE WHITE AT CABINETRY INTERIOR SWITCH LETTER DENOTES FIXTURE 2. ALL JUNCTION BOX AND CONDUIT INSTALLATION SHALL MEET CURRENT SEISMIC REQUIREMENTS. F RAW FIRE -RATED PARTICLE BOARD/PLYWOOD — RAW WOOD AT NON -EXPOSED SURFACES "ALL CABLING AND WIRING TO BE CONCEALED 3. ALL CABLE BETWEEN BALLAST ENCLOSURES IS: ALUMINUM METAL CLAD TYPE ML LITHONIA RELOC PIN AND SOCKET CABLE SYSTEM PART # QFC12012I2G05GLAP UL # 810E G WHITE LAMINATE PIONITE SW811-S OPAQUE WHITE AT SHOWCASE INTERIORS H BEIGE ALABASTER SOLTER PLASTICS OPAQUE GRAY AT KIOSK PYLONS & SHOWCASE FRAMES I DARK GRAY CARPET — DARK GRAY AT KIOSK PLATFORM J STEEL 18 GAUGE METAL AT KIOSK EXTERIOR TOEKICK ' ELECTRICAL NOTES HARDWARE/PARTS SCHEDULE 1. THE FOLLOWING ARE PROVIDED BY LANDLORD: A. 60 AMP, 208/120V, SINGLE PHASE CIRCUIT BREAKER AT LANDLORD'S ELECTRICAL PANEL B. ELECTRICAL CONDUIT WITH CONDUCTORS SIZED FOR THE SERVICE PROVIDED FROM LANDLORD'S ELECTRICAL PANEL TO WITHIN TENANTS KIOSK IN A FINISHED ELECTRICAL MONUMENT WITH COVER. C. 1' DIA. EMPTY TELEPHONE CONDUIT FROM LANDLORD'S TELEPHONE PANEL STUBBED TO WITHIN TENANTS KIOSK WITH PULL STRING IN EXISTING ELECTRICAL MONUMENT WITH COVER PLATE. CODE FINISH MANUFACTURER / MODEL COLOR REMARKS HW1 SATIN NICKEL HARDWARE RESOURCES METAL 4 1/2" CURVE PULL HW2 CLEAR ACRYLIC N.B.I. SLIDING DOOR HANDLE/PULL HW4 SYMBOL LEGEND NOTE: ALL OUTLETS ARE NEW UNLESS OTHERWISE NOTED. P1 SLIDING DOOR N.B.I. SEE FINISH SCHEDULE P2 0 WALL -MOUNTED DUPLEX ELECTRICAL OUTLET WALL -MOUNTED FOUR-PLEX ELECTRICAL OUTLET I WALL -MOUNTED DEDICATED ELECTRICAL OUTLET I, H WALL -MOUNTED DUPLEX ELECTRICAL OUTLET, MOUNTED HORIZONTALLY AT 32' A.F.F. VF WALL -MOUNTED DEDICATED FAX JACK - MOUNTED AT 18' AF.F. VT WALL -MOUNTED VOICE JACK - MOUNTED AT18'A.F.F. RECEIVED VT WALL MOUNTED DATA JACK - MOUNTED ATIB'AF.F. crrY OF TUKWILA v WALL -MOUNTED (1) VOICE AND (2) DATA JACK - MOUNTED AT 18' A.F.F. 7; 0) BUILDING STANDARD FLOOR CORE POWER AND TELEPHONE/DATA BASE FEED MAR 2 0 2014 LEASE LINE P3 EQUIPMENT SCHEDULE FOR REFERENCE ONLY - TENANT TO COORDINATE WITH CONTRACTOR / FABRICATOR. KEY NUMBER QTY. ITEM MANUFACTURER /MOD0.NO. DIMENSION WIDTH DEPTH HEIGHT SUPPLIED BY G.C. TENANT INSTALLED BY G.C. TENANT REMARKS EQI 1 P.O.S. SYSTEM — X X EQ2 2 MONITOR — X X EQ3 3 — X X O MODULAR CASEWORK TYPE, SEE SHEET A3.0 L— EQa 4 — X X TYPE , SEE SCHEDULE FOR OVERALL PERMIT CENTER CASEWORK DIMENSIONS EQ5 5 — X X EQ6 6 — X X MODULE KEY PYLON AND MINI PYLON : DSEE ETAILS SHEET A4.0 FOR ELEVATIONS AND EQT 7 — X X E08 8 1 NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 Lei Q Xd ocn I a. i REVISIONS DATE., SIOEMMN SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 JOBN DATE SCALE 19705 02/21/14 AS NOTED PAGE A0.2 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 City of TiikWila BUILDING DIVISION 1 ' 3D RENDERING N.T.S. Combustible kiosks or other structures shall not be located within the mall unless constructed of any of the following materials: 1.4 Fire -retardant -treated wood complying with IBC Section 2303.2 1.5 Foam plastics having a maximum heatelease ate te not greater than 100kW (105 Btu/h) when test accordance with the exhibit booth protocol in UL 1975. Aluminum composite material (ACM) having la flame spread index of not more than 25 and a smoke - developed index of not more than 450 when tested as an assembly in the maximum intended for the use in accordance with ASTM E 84 or UL 723. �k^ PERMIT CENTER 1 11, NAKAMURA•BEEMAN, INC. 8520 WELISFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W rnw in UQ PARADISI J Xa o co L I W 0 No. REVISIONS DATE 'SIDEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 02/21/14 PAGE A1.0 /♦ 1 \`2 SEE SHORT PYLON DETAILS ON PAGE A3.2 '1 51 1/2 120 3 A3.0 89 23 180 5 36 51 1/2 4/ O \\ 17 A.D.A. GATE e1 ADA COMPLIANT RAMP 1:12 SLOPE PER A.D.A 4.1.6(3)(ii) 23 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 City of tukwila tiBUILDING DIVISION 15 54 PLATFORM 74 120 54 (E) 23 o O f-4-/-4 54 21/32 FINISH10 PLAN 1/2 -- 54 21/32 180 54 21/32 SEE TALL PYLON DETAILS PAGE A3,1 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER i AT-B I NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W a PARADISI c `�'Q Xa ocn D uJ 0 , No. REVISIONS DATE SIDEMAN( SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 DATE 02/21/14 AS NOTED PAGE A2.0 yREVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 City of Tukwila BUILDING DIVISION 1 EL1'-0"EVATION A 3I4"= 1 SEE SHORT PYLON DETAILS PAGE A3.2 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER i NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 6% 1411 W PARADISI UME KIOSK 35 LEVEL 1 aw `r)Q xa ocn r W 0 No. REVISIONS DATE SIDEMARI( SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 DATE SCALE 02/21/14 AS NOTED PAGE A2.1 9 SHORT PYLON f2 54 42 36 8 0 85 13 110 2ELETI0NB 11OR 3/4'I= 4� 89 107 10 2 1 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 City of Tukwila BUILDING DIVISION 36 42 • RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER i NAL4MURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W aW in U PARADISI XC o (n D W 0 , Ha REVISIONS DATE SIOEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 ,G&1 GTE SCA 19705 02/21/14 AS NOTED PAGE A2.2 •ji 0 0 52 54 4.6 54 0 � o� co 9 10 15 t� 0 50 21/32/ 0 50 21/32 50 21/32 i REVIF FOR CODE COMPLIANCE APPROVED APR 04Mk • City of Tukwila BUILDING DIVISION 3 3/4"=V-0" ELEVATION C 164 180 4 co 48 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER J NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 inw in UQ X� o cn C a_ , DATE./ N. REVISIONS SIDEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 PAGE 19705 02/21/14 AS NOTED A2.3 9 84 42 c • 42 36 t 21 CD PQRQBOBC rog H 30 74 70 REVIEWED FOR CODE COMPLIANCE APPROVED SEE APR 04 2014 TALL PYLON DETAILS PAGE A3.1 BUILDING Tukwila i 1 0 23 4 ELEVATION D 3/4"=1'-0" 46 13 110 112 12 1 36 42 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER 1 i T-B 1 NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 aW `nQ X< o (i) ir— , .Nn. REVISIONS DATE, SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 [G.. 19705 DATE 02/21/14 s AS NOTED PAGE A2.4 f NOTE: ***ADD METAL EDGE (VERTICAL EDGE ONLY) FOR WOOD SLIDING DOORS 1 1• 23 co 51 1/2 A 0 A 0 oCK \\ \\ NN N\ N\ NN NN NN3�N / 2 \\ \ N\\N \\N \\\ \\ \\ \\ \\ \\ \N \\ \\\\ \\ PLATF❑R 46 33 36 1/2 < / LICK A o o 1 A rLOCK } INTERIOR ELEVATION A • REVIEWED FOR CODE COMPLIANCE OMLIACE APPROVED APR 04 k City of Tukwila BUILDING DIVISION 3/4"=1'-0" 134 $ 3: 2- /2 23 1' 54 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER r 1 NAKAMURA-BEE iMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W w in UQ xa oco PARADISI D I W 0 , Na REVISIONS DATE SIOEMARI( SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 : 02/21/14 SrwLE AS NOTED PAGE A2.5 NOTE: ** ADD METAL EDGE (VERTICAL EDGE ONLY) FOR WOOD SLIDING DOORS 36 INTERIOR ELEVATION B 3/4"=1'-0" SEE TALL PYLON DETAILS PAGE A3.1 A'-LOCK o co rLOCK A' -LOCK o OA A, VLICK NN\���� NN\ 2 N 2- 74 21 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER 1 NAK MURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PERFUME KIOSK E # 9065 LEVEL 1 %- UQ D X d o r W 0 , "sue SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mali, Seattle, WA 98188 (206) 246-0423 • 19705 :A: 02/21/14 AS NOTED PAGE A2.6 I/ 1 NOTE: ENEADD METAL EDGE (VERTICAL EDGE ONLY) FOR WOOD SLIDING DOORS 23 39 21/32 54 21/32 co AL 0 • t toCK 3 ]/2 \\\\\\\\\\\\\\\ \\\\\\\ \\ \\\'\\�N\\\\\\\\N\\\\\\N \\\\\\ 39 21/32 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 201k City of Tukwila BUILDING DIVISION 7L K I 2- 134 3 314"=1' INTE0RIOR ELEVATION C -" 1 PLATFORM 23 1' 54 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER ►rj 1-- NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI aw in UQ Xd D CO 0 REVISIONS DATE SIDEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 DATE 02/21/14 SCALE AS NOTED PAGE A2.7 Ir 1 NOTE: ***ADD METAL EDGE (VERTICAL EDGE ONLY) FOR WOOD SLIDING DOORS 36 4 314"=1'-0" INTERIOR 23 } 1`) A'-LOCK co 0 I BLOCK 8 AtD2K � co 2 w P1 o -L❑ K 3 1/2 74 PLATFORM REVIEWED FOR CODE COMPLIANCE APPROVED APR 04 2014 City of Tukwila BUILDING DIVISION SHORT PYLON 36 54 RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER NAIL4MURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W a w En U PARADISI G Xd oc/) I LLB 0 1No. REVISIONS DATE," SIDEMAW( SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 DATE SCALE 02/21/14 AS NOTED PAGE A2.8 t - J NOTE: *++ADD METAL EDGE (VERTICAL EDGE ONLY) FOR WOOD SLIDING DOORS REVIEWED FOR CODE COMPLIANCE APPROVED AN 0 4 2014 LG SMD LED City of Tukwila BUILDING DIVISION 0 42 34 4 0 154 21 2 1 6 0 34 0 0 ELEC, BALLAST 5 -2 O 17� 11 8 1 11/2 SIDE SECTION @ 42" TALL SHOWCASE EDGES & TOP L OF 1' THICK 13 23 ACRYLIC TO BE ILLUMINATED LG SMD LED 0 lo--- R1 LED O 0 0 42 0 4 0 7 1 2 15 0 164 1 0 34 5 0 0 0 ELEC, BALLAST 0 177 1$ 2 1 1lSID2' 1'-0E "SECTION @ 54" TALL SHOWCASE LG SMD LED 0 54 0 0 4 462 0 15 0 O 0 ELEC BALL -2 O / G 4 17 $ 1 SIDE SECTION @ 42" TALL SHOWCASE 1121�. W/ COUNTER DISPLAY RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER J NAK4MURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 a `n Q Xa o v) 1 W No. REVISIONS DATE, SIDEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 DATE 02/21/14 sE AS NOTED J PAGE A3.0 ,J ff61 BLACK 1 /2" THICK LETTERS ON BACKLIT WHITE PLEXI er6 R1 LED INSIDE TO ILLUMINATE PLEXI 84 t 21 H CJ rog 30 1 SIDE SECTION @ TALL PYLON FRONT VIEW @ TALL PYLON BLACK 1 /2" THICK LETTERS ON BACKLIT WHITE PLEXI 84 COREVIEWED FOP DE COMPLIANCE APPROVED APR 0 4 2014 City of Tukwila BUILDING DIVISION 1 4-/ 3 REAR VIEW @ TALL PY�9'OFTUKWILA MAR 2 0 2014 PERMIT CENTER e AN NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 aLi 1-.0Q D xa_ ocn W 0 , ‘._No. REVISIONS OATS., SIOEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 19705 [J. ATE 02/21/14 ��.E AS NOTED PAGE A3.1 BLACK 1 /2" THICK LETTERS ON BACKLIT WHITE PLEXI 4P 48 R1 LED LIGHTING INSIDE TO ILLUMINATE PLEXI 1 SIDE SECTION @ SHORT PYLON 1 1/2°=1-0 P1 L n 48 4 • REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2014 City of Tukwila BUILDING DIVISION 2 FRONTo• VIEW @ SHORT PYLON 11I2 =1- RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER J NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W FARADISI UME KIOSK 35 LEVEL 1 aO T-Q Xa O v) a- -I''''.REVISIONS DATE SIDEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 JOBS 19705 DATE 02/21/14 s AS NOTED 1 PAGE A3.2 �I i'--- L❑CATI❑N OF ELECTRICAL "J" BOX TO BE VERIFIED BY ON SITE TENANT C❑❑RDINAT❑R. ANY UPGRADES TO WHAT IS EXISTING WILL BE MADE BY TENANT AT TENANT'S EXPENSE. R1 LED LIGHTING AT PYLONS WHITE LG SMD LIGHTING AT SHOWCASES LED LIGHT SMALL DISPLAY CASE & 1' PLEXI WHITE LG SMD LIGHTING AT SHOWCASES Y 12 GAUGE SJ, POWER CORD PLUG INT❑ EXISTING MALL RECEPTACLES WHITE LG SMD LIGHTING AT SHOWCASES I*C❑NNECT TO MALL POWER --,_:) ***ELECTRICAL STUB -UP AND LAYOUT TO BE C❑❑RDINATED WITH MALL ❑PS PRI❑R TP INSTALLATI❑N \ n n n n S LC SQUARE D LOAD CENTER PART # Q02L3OS UL# J-1244 W/ 2-15 AMP CIRCUIT BREAKERS LED LIGHT FOR 1' PLEXI LED LIGHT FOR 1' PLEXI ALL CABLE BETWEEN BALLAST ENCLOSURES IS: ALUMINUM METAL CLAD TYPE ML LITH❑NIA RELOC PIN AND SOCKET CABLE SYSTEM PART # QFC120 12/2G05GLAP UL # 810E WHITE LG SMD LIGHTING AT SHOWCASES *** N,B,I, TO VERIFY AT J❑BISTE WHETHER PR❑VIDED ELECTRICAL SOURCE IS AN OUTLET OR RECESSED "J" BOX. TENANT TO MODIFY SYSTEM TO FIT EXISTING C❑NDITI❑NS, 1 POWERIDATA/LIGHTING PLAN " 1I2"=1'-0" LED LIGHT SMALL DISPLAY CASE & 1' PLEXI . REVIEWED FOR CODE COMPLIAN( APPROVED APR 0 4 2014 City of Tukwila BUILDING DMV18IO WHITE LG SMD LIGHTING AT SHOWCASES R1 LED LIGHTING AT PYLONS RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER / v ***ALL CABLING AND WIRING TO BE CONCEALED*** 1* NAKAMURA-BEEMAN, INC. 8520 WELLSFORD PLACE SANTA FE SPRINGS, CA 90670 PHONE: 562 696 1400 FAX: 562 696 1411 W PARADISI UME KIOSK 35 LEVEL 1 IZ W in U Q D Xa ocn w ANw REVISIONS DATE, SIDEMARK SOUTHCENTER MALL (WESTFIELD) 2800 Southcenter Mall, Seattle, WA 98188 (206) 246-0423 �. 19705 DATE 02/21/14 SCALE AS NOTED PAGE A5.0 I PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D 14-0090 PROJECT NAME: PERFUME PARADISE DATE: 03/20/2014 SITE ADDRESS: 2800 SOUTHCENTER MALL, K-1022 X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division M' Public Work pcN icw& 07,11,11 ').t•ek AyA_ Fire Preventiop . Planning Division III Structural ❑ Permit Coordinator C PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reeviews) (ie: Zoning Issues) Notation: kici.e1v A-I.0 �tV12 `\ re DUE DATE: 04/22/14 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 DIRTY WORK Page 1 of 2 0 Washington State Department of Labor & Industries DIRTY WORK Owner or tradesperson GIBSON, GUY DALE Principals GIBSON, GUY DALE WA UBI No. 602 374 732 12369 S NEW ERA RD OREGON CITY, OR97045 503-720-7558 Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. DIRTYW*916B1 Effective — expiration 01/21/2009 — 01/31/2015 Bond Wesco Insurance Co Bond account no. 46wb011167 $12,000.00 Received by L&I Effective date 12/06/2012 01 /21 /2013 Insurance Security National Insurance $1,000,000.00 Policy no. NA104222602 Received by L&I Effective date 01/21/2014 01/21/2014 Expiration date 01/21/2015 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602374732&LIC=DIRTYW*916B 1 &SAW= 04/16/2014