Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D14-0123 - CHALET SOUTH - CARPORT REPAIR
CHALET SOUTH CARPORT REPAIR 4004 S 158 ST BLDG 5 D14-0123 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 1508000000 4004 S 158 ST 5 CHALET SOUTH CARPORT REPAIR Permit Number: D14-0123 Issue Date: 4/30/2014 Permit Expires On: 10/27/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: „ WA, CRAIG GOODMANSEN 1115 N 140 ST, SEATTLE, WA, 98133 MCLEOD CONSTRUCTION LLC 1115 N 140 ST, SEATTLE, WA, 98133 MCLEOCL951DD Phone: (206) 545-7837 Phone: (206) 545-7837 Expiration Date: 3/8/2015 DESCRIPTION OF WORK: REPAIR DAMAGE CAUSED BY CAR STRIKE ON CARPORT - REPLACE DAMANGED BEAM AND ISNTALL SUPPORT GUSSETS TO TRUSS WORK. Project Valuation: $2,800.00 Fees Collected: $257.98 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Occupancy per IBC: U Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: LYIL Date: 11` 36--1 4-f I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature` Print Name: Ge-ct Date: 4r— r� ll-K This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No, Date Application Accepted: Date Application Expires: . CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 150800-0360 Site Address: 4004 South 158th St. Tukwila, WA 98122 Suite Number: Floor: Tenant Name: PROPERTY OWNER Name: Chalet South Home Owners Association Address: 4004 South 158th ST City: Tukwila State: WA Zip: 98188 CONTACT PERSON communicator ving all project Name: Craig Goodmansen Address: 1115 N 140th ST City: Seattle State: WA Zip: 98133 Phone: (206) 545-7837 Fax: (206) 545-7252 Email: craig@mcleodconstruction.com GENERAL CONTRACTOR INFORMATION Company Name: Mcleod COnstruction Address: 1115 N 140th St City: Seattle State: WA Zip: 98133 Phone: (206) 545-7837 Fax: (206) 545-7252 Contr Reg No.: MCLEOCL951DD Exp Date: 03/08/2015 Tukwila Business License No.: 0995302 New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Company Name: N/A Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Pacific Engineering Technologies Engineer Name: R Barrett Address: 1700 Westlake Avenue North City: Seattle State: WA Zip: 98109 Phone: (206) 281-7500 Fax: (206) 281-4611 Email: LENDER/BONA, ISSUED. (required for projects $5,000 or greater per RCW 19.27.095j Name: N/A Address: City: State: Zip: H:\ApplicationsWomis-Applications On Line12011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION 206-431-3670 Valuation of Project (contractor's bid price): $ 2,800 Describe the scope of work (please provide detailed information): Repair damaged caused by car strike on carport. replace damaged beam and install support gussets to truss work. Will there be new rack storage? ❑ Yes Existing Building Valuation: $ m.. No If yes, a separate permit and plan submittal will be required. Building Areas in,Square Footage Below. Addition to Existing Structure 1* Floor Type of Construction per IBC Type of Occupancy; per 2nd Floor` 3r4 ors • tb Basement Accessory Structure.*.. Attached; Detached a -Attached C Detached_Carpor 380 Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. HAApplications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic Svstem: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) O ...Bond 0 .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance O ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) 0 ...Traffic Impact Analysis 0 ...Hold Harmless — (SAO) 0 ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage O ...Sanitary Side Sewer 0 .. Abandon Septic Tank ❑ .. Grease Interceptor 0 ...Cap or Remove Utilities 0 .. Curb Cut ❑ .. Channelization 0 ...Frontage Improvements 0 .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control 0 .. Looped Fire Line 0 .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection " Irrigation Domestic Water ❑ ...Permanent Water Meter Size... " WO # ❑ ...Temporary Water Meter Size .. WO # O ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private 0 O ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 IT, APPLD ATION.NO." Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNERDR AUTHOAGENT: Signature: Date: 04/17/2014 Print Name: Craig Goodmansen Day Telephone: (206) 545-7837 Mailing Address: 1115 N 140th ST Seattle WA 98133 City State Zip H:\Applications'Forms-Applications On Line \2011 Applications\Pertnit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $257.98 D14-0123 Address: 4004 S 158 ST 5 Apn: 1508000000 $257.98 DEVELOPMENT $250.52 PERMIT FEE R000.322.100.00.00 $149.10 PLAN CHECK FEE R000.345.830.00.00 $96.92 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $7.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1833 R000.322.900.04.00 $7.46 $257.98 Date Paid: Thursday, April 17, 2014 Paid By: MCLEOD CONSTRUCTION LLC Pay Method: CHECK 15664 Printed: Thursday, April 17, 2014 8:51 AM 1 of 1 INSPECTION RECORD Retain a copy with permit RMIT NO. ik CITY OF TUKWILA BUILDING DIVISION C,. 6300 Southcenter Blvd„ #100, Tukwila. WA.98188 (206) 431-.3670 Permit Inspection Request Line (206) 431-2451 Peg % 1 �.T • • �,th 44' 145bm 5\7• d per applicable codes. T of Inspection: r 13, rke-, Date Called Date. Wanted: Requester: Phone No: U I 4. p.m. orrections required prior to approval. COMMENT& rmrc ek Date: FEE REQUIRED. Prior to next inspection. fee.rttust be center Blvd.. Suite 100. gall to schedule re nspect on. ress: Oc' 5$ Special Instructions: COMMENTS: t INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF`TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: t _ ' r n f Inspect a-w Date Called: Requester: Phone No: EJCorrections required prior to approval. PECTION FEE REQ IRED. Pr! ¢r o next inspection, fee 4nust be d at 6300 Southcenter vd.. Suite 100. Call to schedule reinspection. Pacific Engineering to.sco?Technologies Chalet South Carport Repair 4004 South 158`" Street Tukwila, Washington Job No.: 14058 Calculations 0>P4IPWASPI. 4� 1970 u'0 wk' REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 8 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 7 2014 PERMIT CENTER 1+- 0 (2.3 `Project No; 140Date: 9 / . i. / / Sheet: Of: ►t'-t Project Name: Comp. By: Chic By' Contents; Pacific Engineering Tech 12 ologies 1700 Wootloke Avenue North — .Suits 100 Seattle, komhington.98109-6212 teiephon. (206) 261-7500 Focrimar [206j 261-4611 {600j 621-7300 Y --Na4 T Loads: LC 1, D•S Reeu!la for LC 1, 0+-S 7 Pacific Engineering Technologies R. Barrett 14058 - Chalet South Carport Apr 11, 2014 at 9:36 AM untitled.r2d 3 /, r 1� D+S Yes 1 1 2 1 Joint Reactions Company : Pacific Engineering Technologies Apr 11, 2014 Designer : R. Barrett 9:37 AM Job Number : Checked By: Basic Load Cases BLC Description DL Category None X Gravity Y Gravity Joint Point Snow Load Combinations None Distributed 3 3 Description SolvePD... SR... BLC Factor BLC Factor BLC Factor BLCFr BLC Factor BLC Factor BLC IFactor B LC Factor LC Joint Label X fk Y tk MZ fk- 1 1 N1 0 .742 0 2 1 N3 0 .742 0 3 1 Totals: 0 1.483 4 1 COG (ft): X: 10 Y: 3.5 Member Section Forces (By Combination) LC Member Label Sec Axial Shear Momentfk-ft 1 1 M 1 1 -.697 0 .016 2 2 -.697 0 .016 3 3 -.697 0 .016 4 4 -.697 0 .015 5 5 -.697 0 .015 6 1 M2 1 -1.5 .015 .015 7 2 -1.5 .015 -.022 8 3 -1.5 .015 -.058 9 4 -1.5 .015 -.095 10 5 -1.5 .015 -.131 11 1 M3 1 1.666 -.218 -.131 12 2 1.623 -.096 .16 13 3 1.58 .027 .223 14 4 1.537 .149 .06 5 1.495 .272 -.331 _15 16 1 M4 1 1.174 -.251 -.331 17 2 1.131 -.129 .022 18 3 1.088 -.006 .148 19 4 1.046 .116 .046 20 5 1.003 .239 -.283 21 1 M5 1 .101 -.239 -.283 22 2 .064 -.134 .014 23 3 .027 -.029 .144 24 4 -.009 .076 .106 25 5 -.046 .181 -.098 26 1 M6 1 .186 -.016 -.098 27 2 .186 -.016 -.069 28 3 .186 -.016 -.041 29 4 .186 -.016 -.012 _ 30 5 .186 -.016 .016 31 1 M7 1 .878 0 0 32 2 .878 0 0 33 , 3 .878 0 0 _ 34 4 .878 0 0 35 5 .878 0 0 36 l 1 I M8 1 _ -.52 0 0 RISA-2D Version 6.0 [C:\RISA2D\untitled.r2d] Page 1 11/ Company : Pacific Engineering Technologies Designer : R. Barrett Job Number : Apr 11, 2014 9:37 AM Checked By: Member Section Forces (Bv Combination) (Continued) LC Member Label 37 Sec Axial[k] 2 -.52 Shear[k] 0 Moment[k-ft] 0 38 39 3 -.52 0 0 4 -.52 0 0 40 41 5 -:52 0 0 =42' 1 M9 1 .614 .614 0 0 0 43 3 .614 0 0 4 4 .614 0 45 5 .614 0 0 RISA-2D Version 6.0 [C:\RISA2D\untitled.r2d] Page 2 Project Name: Project No• �kic Date: Sheet* Of. 5vL4 t Comp, By: Chk.By: Pacific Engineering Technologies 1700 Westlake AvenueNorth— Suite 100 Seattle, Washington 98109-6212 Telephone: (206) 281-7500 roceimie: (206) 281-4611 (800] 621-7300 SE ( to ; `5i Project No• Date: Sheet:. loft Project Name: C frioNc1 QOM 5tynn Pness Pacific Engineering Technologies 1700 Westlake Magnus( North - Suite 100 Stott*, Washington 98109-6212 Telephone: {206) 281-7500 Faceimilie: [206) 281-4611 j800) 821-7500 NI Opt_ PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0123 DATE: 04/17/2014 PROJECT NAME: CHALET SOUTH CARPORT REPAIR SITE ADDRESS: 4004 S 158 ST, BLDG 5 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: V T.19 Building Division 1.369 k kVA Public Works it)//4 Fire Prevention Structural C/(L M. Oc Till'1 w Planning Division En Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/22/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required C n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 05/20/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MCLEOD CONSTRUCTION LLC Page 1 of 2 Washington State Department of Labor & Industries MCLEOD CONSTRUCTION LLC Owner or tradesperson GOODMANSEN, CRAIG D Principals GOODMANSEN, CRAIG D, PARTNER/MEMBER GOODMANSEN, ANDREA S, PARTNER/MEMBER Doing business as MCLEOD CONSTRUCTION LLC WA UBI No. 602 474 102 1115 N 140TH ST SEATTLE, WA98133 206-545-7837 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MCLEOCL951 DD Effective — expiration 03/07/2005— 03/08/2015 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 545759C $12, 000.00 Received by L&I Effective date 03/07/2005 03/07/2005 Insurance INTERNATIONAL INS CO OF HANNOV $1,000,000.00 Policy no. IG01300001500 Received by L&I Effective date 09/11/2013 10/24/2012 Expiration date 10/24/2014 Insurance history https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602474102&LIC=MCLEOCL951 DD&SAW= 04/30/2014 PROJECT NARRATIVE Plan rE t;p ;ro\ the vic of app 11'-I"± 8'6 CARPORT 107N FOUNDATION PLAN 44? SCALE: 1/4" = 1'-0" EXISTING WOOD FRAMED STORAGE SHED EXISTING ROOF SHEATHING NEW 6x BEAM PER PLAN pomit No. view approval is subs to errors and omissions. aI of construction documents does not authcriZG SECTION ation of any adopted code or ordinance. Receipt SCALE: 3/4" = 1'-0" oved Fisk' ,., N (, w.. ed: PROVIDE TEMPORARY SHORING AS REQ'D DURING REPAIRS SECTION 1 SCALE: I/4" = 1'-0" \1 4 WOOD FRAMED STORAGE UNIT 41 NEW PLYWOOD GUSSET PLATES EACH SIDE OF TRUSS TO BE REPAIRED (TYP. 4 PLACES) EXIST. Sx6 P.T. POST ON EXIST. 12"+ CONC. SONOTUBE, TYP. EXIST. BLOCKING (OR NEW AS REQ'D) TOENAIL TO BEAM W/ 10d NAILS AT 4" O.C. INSTALL (I) NEW SIMPSON H2.5A CLIP EACH TRUSS REUSE EXISTING POST CAP AND FASTENERS 8'-6"t P EXIST. 0 6x1 O IY o 01 = U O N L NEW 6x10, A tioQ N NEW 6xI0 ® 2 t.� - CARPORT eNA ROOF FRAMING PLAN SCALE: 1/8" = 1'-0" 3/4" MIN. PLYWOOD GUSSET PLATE EACH SIDE OF TRUSS TO BE REPAIRED EXIST. POSTS EXIST. ASPHALT PAVING EXIST. CONC. FOOTINGS EXISTING ROOFING AND SHEATHING EXISTING EXTERIOR SIDING EXIST. POST TO REMAIN 4'-0" MIN. 3 /, SIMPSON 1-12.5A CLIP, TYP. SECTION 2 SCALE: 3/4" = I'-0" SECTION SCALE: 3/4" = 1'-0" STORAGE ROOF BELOW NOTE: IF ADDITIONAL TRUSSES ARE OBSERVED TO HAVE LOOSE PRESS PLATES AT THE BEAM, PROVIDE ADDITIONAL GUSSET PLATE REPAIRS AS REQUIRED PROVIDE TWO ROWS I0d NAILS AT 3" O.C. STAGGERED EXISTING ROOFING AND SHEATHING TO REMAIN NEW 6x BEAM PER PLAN EXIST. BLOCKING (OR NEW AS REQ'D) TOENAIL TO BEAM W/ I0d NAILS AT 4" O.C. NEW 6x BEAM PER PLAN REUSE EXISTING POST CAP AND FASTENERS S 15aTH ST. CARPORT. WORK THIS PERMIT SCHEMATIC SITE PLAN ?' SCALE: I" - 100.0' SECTION ALTERNATE NAIL INSTALLATION EACH SIDE OF GUSSET PLATES NEW PLYWOOD GUSSET EXIST. ROOF TRUSS TO BE REPAIRED 3 SCALE: 1 1/2" = I'-0" SEPARATE PERMIT REQUIRED FOR: %l Mechanical Electrical Plumbing 14 Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall bemade mm e to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees ALL INFORMATION ON THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC. © COPYRIGHT 2014 THE PURPOSE OF THIS DRAWING IS TO SHOW THE DETAILS NECESSARY TO RESTORE THE CARPORT FRAMING TO A CONDITION OF LIKE KIND AND QUALITY THAT EXISTED PRIOR TO THE VEHICLE IMPACT. THE REPAIR INCLUDES THE REPLACEMENT OF THE BEAM SUPPORTING THE ROOF FRAMING AND THE STRENGTHENING OF THE TRUSSES AT THE SOUTHWEST CORNER OF THE STRUCTURE. NO REVIEW OF THE EXISTING LATERAL SYSTEM OR THE ADEQUACY OF THE EXISTING UNDAMAGED FRAMING ELEMENTS HAS BEEN PERFORMED. ARCHITECTURAL DETAILING SUCH AS BUT NOT LIMITED TO: WATERPROOFING, FLASHING, ROOFING, GUTTER INSTALLATION, ETC., IS NOT INCLUDED IN THESE DRAWINGS. ""Si54IN St` 5 I SITE s 1S3th st _. 5 I VICINITY MAP f'. SCALE: 1/8" = 1'-0" LEGAL DESCRIPTION CHALET SOUTH CONDOMINIUM PCT OF VALUE 1.44 PLAT BLOCK: BLD 5 PLAT LOT: UNIT 36 ASSESSOR'S NUMBER: 1501300-0360 et En N `Z S 95rh S REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 8 2014 City of BUILDIN /1/l"- ita IVISION STRUCTURAL. NOTES: CODE: THE INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION WITH WASHINGTON STATE AMENDMENTS. LIVE LOADS: ROOF SNOW LOAD 25 PSF NAILS: NAILING SHALL BE IN ACCORDANCE W/ NAILING SCHEDULE TABLE 2304.9.1 IN THE IBC. ALL NAILS SHALL HAVE ROUND HEADS UNLESS NOTED OTHERWISE ON THE DRAWINGS. NAIL LENGTHS AND DIAMETERS SHALL BE AS FOLLOWS: I0d 3" x 0.131" DIA. I0d COMMON 3" x 0.14S" DIA. LIGHT GAUGE FRAMING CONNECTORS: NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS AND OTHER CONNECTING DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY THE SIMPSON STRONG -TIE COMPANY, DUBLIN, CALIFORNIA. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL LOAD CAPACITIES. CONNECTORS SHALL BE FASTENED TO THE FRAMING MEMBERS USING THE NUMBER AND TYPE OF FASTENERS CALLED FOR BY MANUFACTURER. HANGERS AND CLIPS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE ZMAX/HOG GALVANIZED CONNECTORS. ALL HANGER FASTENERS USED WITH' ZMAX/I-IDG GALVANIZED CONNECTORS SHALL BE HOT -DIPPED GALVANIZED PER ASTM A153 OR SDS SCREWS WITH DOUBLE BARRIER COATING. STRUCTURA LUMBER 4 TIMBER: ALL LUMBER SHALL BE GRADED IN ACCORDANCE WITH CURRENT ULUPA STANDARD GRADING RULES FOR WESTERN LUMBER. USE THE FOLLOWING SPECIES AND MINIMUM GRADE: COLUMNS DF.-L 4P2 Fc=I350 PSI BEAMS (6x 4 LARGER) DF.-L "2 Fb=815 PSI ALL PLYWOOD SHALL BE APA RATED SHEATHING, EXPOSURE I, GRADE C-D. ALL LUMBER IN CONTACT WITH GROUND OR CONCRETE SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA STANDARD C2 WITH AMMONIACAL COPPER ZINC ARSENATE (ACZA) TO 0.25 PCF RETENTION WITH AN ASSAY ZONE 0.4" IN DEPTH. PAINT ALL SCARS, CUTS AND DRILL HOLES WITH TWO COATS OF COPPER NAPTHENATE OR CREOSOTE. MISCE LANEOUS: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. REPETITIVE FEATURES MAY BE DRAWN OR CALLED OUT ONCE, BUT SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. ALL WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY STANDARDS. PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENINGS HAVE BEEN INSTALLED. SAFETY: THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION, TEMPORARY BRACING, SHORING, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES IN CONNECTION WITH THE WORK THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITION ON THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE REQUIRED AND/OR IMPLIED DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF CONTRACTOR'S PERFORMANCE DOES NOT, AND IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN ON OR NEAR NE CONSTRUCTION SITE. RECEIVED CITY OF TUKWILA ILVoI 4) 0 c s ct 0 Z o O N 0 q0. 1700 Westlake S N N co N N (N0 000 N N N. hi 2.E; 88o elD gu) 0•i:44 ,� (CO 2;1 ", cli et()E(4 sc.: 0 ,,/) P4 to ;41 0 U §f-rx— t_oL.21uQ-- 1v L tZ0 cs 1 OF City Of Tiukwila 4/ 15/201.s8W LDING DIVISION 14058.wd. APR 1 7 2014 PERMIT CENTER 1 Job No. 14058.00