Loading...
HomeMy WebLinkAboutPermit D14-0130 - SPEC A - ADA RESTROOMSPEC A 1183 ANDOVER PK W D14-0130 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3523049093 1183 ANDOVER PARK W BLDG A Project Name: SPEC A Permit Number: D14-0130 Issue Date: 5/27/2014 Permit Expires On: 11/23/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CWWA SOUTHCENTER 4 LLC PO BOX A-3879 C/O EQUITY OFFICE MGMT LLC, CHICAGO, WA, 60690 DAVID KEHLE, ARCHITECT 1913 BONAIR DR SW , SEATTLE, WA, 98116 ALEXEEV CONSTRUCTION PO BOX 731152 , PUYALLUP, WA, 98373 ALEXECS934P9 FUNDED BY OWNER Phone: (206) 433-8997 Phone: (253) 230-4788 Expiration Date: 10/29/2015 DESCRIPTION OF WORK: REMOVE EXISTING RESTROOM AND CONSTRUCT NEW ADA RESTROOM Project Valuation: $8,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: IIIB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $424.58 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and :xamin-d this permit and know the same to be true and correct. All provisions of law and ordinances gov rning his work will be complied with, whether specified herein or not. 1(1 The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating co truction .r the performance of work. I am authorized to sign and obtain this development permit and agree to con• n attac -d to this permit. Signature: !`�'�� Date: t(D�> ivVitt g � l.J Print Name: fat ), QAx. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 18: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 17: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0603 ROOF/CEILING INSUL 0601 WALL INSULATION CITY OF TUX LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwil4 WA 98188 http://www.7ltkwilaWA.gov Building Permit No. DH Project No. Date Application Accepted: OC Date Application Expires: t V 1 Ili For o/rce use onl CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: I ` „/ea.~ Tenant Name: King Co Assessor's Tax No.: Za b4j 1$ Suite Number: PROPERTY OWNER Name:% h ,t:iew Address: I.N i►,ul a. . Aide ci City: ts& State Zip ' m CONTACT PERSON — person receiving all project communic tion Name: Ilp wig, Address: lq `o KL rpaw City:`%.r�it, eStater Zip f ti ,1� e , Et,1QFax:4.40„ C!,�y� 1 Phone: TA. 4'' __ Email: jheLL�K e dq hica at (1XN( GENERAL CONTRACTOR INFORMATION Company Name: Iv Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Floor: New Tenant: Yes ❑.. No ARCHITECT OF RECORD Company Name:go 0 kg le, liaticttrit Architect Name: aaoEfonito Address: 11l(p r;4i6i City:'! t.-he Stater a Zip: qg u k Phone: (0. 433 . b 941 Fax;,&. At , 6461 Email: 4e 4Netile ache 6D1+4 ENGINEER OF RECORD Company Name: It/t I�jj� Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater RCW 19.27.095) Name: 04000 g. �,+M�— V�" Address: City: State: Zip: H.1ApplicationslForms-Applications On Line12012 AppiicationsWermit Application Revised • 2-7.12 dots Revised: February 2012 bh Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ b Existing Building Valuation: $libliii10643 Describe the scope of work (please provide detailed information): VOW& rtfi4arinieetiI ah.Wrgt4er IIev i a3'g" % Will there be new rack storage? ❑ ....Yes 154 ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Type of Construction per ? Occupancy per IBpC, IBC la Floor 0,240 4/4 et 4 ii ii- V Q 4; 2nd Floor i 3rd Floor Floors thru Basement Accessory Structure* Attached Garage ' Detached Garage - Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft):lh Floor area of principal dwelling: Floor area of accessary drve1tina: *Provide documentation tha shows that the principal owner lives in one of the dwellings as his or her primary residence �y t NN��. Number of Parking Stalls Provided: Standard: 4 Compact: Will there be a change in use? 0 Yes Vi No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: tir Sprinklers 0 Automatic Fire Alarm Handicap: 0 None ❑ Other Ispec-fti Will there be storage or use of flammable, combustible or hazardous materials in the building? D Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quannnes aand i%arer ai Scotts Sheets. ,SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approi, ed by Coxrnz. Health Department. H.\ApplicationsWorms-Applications On Line \2012 Application Permit Application Revised - 2-7-12.docx Revised' February 2012 bh Z ej PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR AUTH t`' i ZED GENT: J Signature: Date: I Print Name: {}�() Mailing Address: 1tU:o DP� t2� H:\Applications\Forms-Applications On Line\201 1 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Day Telephone: 400 33 " ►' vt" Cirtib City State Zip Page 4 of 4 DESCRIPTIONS ACCOUNT I QUANTITY I PermitTRAK PAID $263.96 D14-0130 Address: 1183 ANDOVER PARK W BLDG A Apn 3523049093 $263.96 DEVELOPMENT $251.60 PERMIT FEE R000.322 100 00.00 0.00 $247.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $12.36 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2203 R000.322.900.04.00 0.00 $12.36 $2.63.96 Date Paid: Tuesday, May 27, 2014 Paid By: ALEXEEV CONSTRUCTION Pay Method: CHECK 8915 Printed: Tuesday, May 27, 2014 12:15 PM 1 of 1 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK .62 D14 h0130 Address: 1183 ANDOVER PARK W BLDG A Ape:; 352 093 .62 DEVELOPMENT $160.62 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1996 R000.345.830.00.00 $160.62 $160.62 Date Paid: Thursday, May 01, 2014 Paid By: DAVID E KEHLE Pay Method: CREDIT CARD 035776 Printed: Thursday, May 01, 2014 12:37 PM 1 of 1 CATIMSYSTEMS INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 8100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-94)0 Spe Instructions: iype��it.inspecti n: � Date Date Witt 1 I 1 Requester Phone No: • lig&pproved per applicable codes. Corrections rewired prior to approval. COMMENTS: e ) ns PEt TION FEE REQU ED. Prior to nekt inspection. fee must be at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. 01 1-o t3o V INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 431-2451 Projec ='r"r�"Si eiinqL, s. Ai A €-'" �' ( Date Called: Special Instructions: C31ij ,' C 0Ca Date W nted: (p Reque te Phone' .. = 6- Li 76 EApproved per applicable codes. Q Corrections required prior to approval. COMMENTS. , ) f f✓fit. ..� ..+..am _ 4 657 \ JP-TY t'(l/���/� 1 / 111 CTION FEE REWIRED. Prior to ext inspection, fee must he Southcenter Blvd.. Suite 100. Call to schedule reinspectton. d�� INSPECTION RECORD Retain a copy with permit IN PERMIT Na CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Address: Date Called: Specie Instructions: i cad A 'Date Wanted: may//-/9 .m Requester:.....-- 1 jApproved per applicable codes. Corrections required prior to approval. COMMENTS: L 7.) A O'' k k_.Sc� 1 Af , - ,el',A1120Z '' ; R✓vuw ti l or: „AM-7 1-�d A Ck Q . Datg: -i� SPECTION FEE RE IRED. Prior to next inspection. fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER Di q - 0/ PERMIT NUMBERS CITY.OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: /1 (/eG 4_ S Tye of Insp ' n: Ti4-6- Address: / ( ?3 3 ftti"1,L) Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable cod COMMENTS: riCorrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Firer Permits: Occupancy Type: Inspector: /J, "pc. c a-- Date: /r2 . h/ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 and R3 Interior Lighting Summary LGT-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Add 'ess i A - - i Date y 11$ 5 o0402 RpmWA For Building Department Use Applicant Name: I'Wail iiK 7 Applicant Address: L 1-ibti/Z� t�12 �iyy y' I " . Applicant Phone r3e � 3 -M4 !-PIIIION/P4r. Project Description 416 Alteration ED New Building ■ Addition ■ Plans Included Lighting Compliance Path 0 Lighting Power Density Calculations 0 Total Building Performance (►f total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option 0 Building Area Method C Space -by -space Method REVIEwp0 CODE COMpi I Interior Lighting System Description Briefly describe lighting system type and features. meµ,, itutiteo rtettioxAtt APFROVF MAY 1 4 201 City Of Tu BUILDING DIVirl Additions and Change of Space Use (C101.4.3 & C101.4.4) • Addition area or Change of Space Use area complies with all applicable provisions as stand alone project area or Change of Space Use area is combined with existing building lighting systems to demonstrate with all applicable provisions Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum and proposed (i dulling existing if applicable) ligifing wattage of Addition or Change of Use scope. Provide applicable lighting per C405.2 and commissioning of lighting controls per C405.13. Addtion compliance Provide allowed controls Alterations, Renovations and Repairs (C101.4.3.1) ❑ 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing) lighting wattage of project scope if Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG-INT-SPACE) Compliance Form. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope ballast replacement within existing luminaires only - existing total interior building wattage not increased ■ Lamp and/or installed to serve added fixtures and/or fixtures relocated to new circuit applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific controls (C40523), and commissioning of lighting canbols per C40513 • New wiring Provide application lighting panel all applicable lighting controls as noted for New Wiring automatic time switch controls (C405.2.2.1), and commissioning of controls per C405.13. • New or moved Provide lighting [jj Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New liming and commissioning of lighting controls per C405.13. are being made to the interior lighting and space use not c}� -'Ri�r'`Cll rr, ■ No changes CITY OF TUKWILA MAY 0 1 2014 PERMIT CENTER OR ONCE LOP 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 LTG-INT-SPACE Interior Lighting Summary - Space -by -Space 2012 Washington State Energy Code Compliance Forms rnr r•.nnur....i'1 r...._ n, _ > 3 Project Info Pro' Address � �'G �.•- -.._ ...... � 1, r "�'- Date �� 1 ' 1Fj,�.;Ne " For Buildi g Department Use Applicant Name: W9 rEtt, Let ifj I Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2 tiross intenor Area in ft2 watts Allowed (watts/ft2 x area) '11/ea. mice D•°U to} ID.3 Atrium** Enter Height: Retail Display Allowance from LGT-INT-DISPLAY * Select Table C4O5.5.2(2) category from drop down menu. " For atriums, indicate height.Allowed wattage for first 40 feet is 0.03 WA? ht., above 40 feet is 0.02 WAt. ht. Proposed Lighting Wattage Total A 6pA: Allowed Watts to Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 3) Number of Fixtures Watts/ Fixture Watts Proposed -r i Pla 2-ttios. Watt _gig— - riAxe'yGt t.S 1 i o -to s 05listrix salt Retail Display Lighting from LGT-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts lb Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5. 1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C4O5.5.1, note exception number and leave Watts/Fixture blank. 2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 R3 Envelope Summary ENV -SUM 2012 Washington State Energy Code Compliance Forms for Commercial. Groun R1 and ? atnry R2 & R3 Revised June 2013 Project Info Project Address le Date Oil fi�rr�-,,-� I i�0 � &4R i'o- F6 c `l For Building Department Use Applicant Name: tv, E� Ili �riwz/�m�tilr'/ �' ``I, Applicant Address: tilt, �o Yr i! ' V8 ott'U(/ t Applicant Phone: / �j tGvil• Project Description ,,�t ❑ New Building ❑ Addition t# Alteration E Change of Occupancy/Conditioning Compliance Path ❑ Prescriptive E Component Performance i• Total Building Performance Occupancy Group 0 Commercial 0 Group R (R-1 & > 3 story R-2 and R-3) Climate Zone 0 Climate Zone 4/9 0 Climate Zone (eb( See WSEC 301.1 for county list) Vertical Fenestration and Skylight Area Calculation If complying via the Prescriptive path, provide values for vertical fenestration, skylights, gross walls and roof. If complying via the Component Performance path, these values are auto- filled by the ENV-UA form and cannot be edited here. Total Vertical Gross Exterior Fenestration Above Grade % Vertical (rough opening) divided by Wall Area times 100 equals Fenestration 4 + X 100 - Gross Exterior Total Skylight divided by Roof Area times 100 equals % Skylight Nitot + X 100 = Maximum Prescriptive Fenestration Area Vertical Fenestration Whir Skylights 50% Floor Area in DLZ 0 More than 50% of the floor area in daylight zone per C402.3.1.1 Semi -Heated Path gi, Project has semi -heated areas as defined per C402.1.4 Fir Applying wall exception to semi -heated areas 1. To be deemed semi -heated the area is heated but not cooled, and has a max. heating system output capacity between 3.4 — 8 Btuh/ft2. Refer to C402.1.4 for requirements. 2. Semi -heated spaces shall be documented separately from other conditioned spaces — provide separate compliance forms for each condtioned area type. 3. Semi -heated spaces may comply under the Prescriptive or Component Performance compliance path. 4.Envelope elements separating semi -heated from other conditioned spaces shall comply with thermal envelope requirements for an exterior wall. Refrigerated Spaces ❑ Walk-in cooler ❑ Walk-in freezer ❑ Refrigerated Warehouse Cooler ❑ Change of Occupancy/Conditioning Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for these areas may be combined with non -refrigerated areas in the ENV -PRESCRIPTIVE form. Refer Mixed Occupancy and/or Space Conditioning Project includes more than one occupancy type and/or level of space conditioning. Multiple compliance forms may be required. Select all that apply to scope of project: 4rCommercial ❑ Group R1 or >3 story R2/R3 ❑ Refrigerated Space ❑ Fully Conditioned ❑ Semi -Heated ❑ Low Energy' ❑ Group R2/R3 < 3 story *Low energy areas are exempt from all thermal envelope provisions and compliance forms far these areas are not required. Refer to C101.5.2 for exemption. City of Tukwila Department of Community Development 11/3/2014 DAVID KEHLE, ARCHITECT 1913 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. D14-0130 SPEC A 1183 ANDOVER PK W Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/20/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/20/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ifer Marshall it Technician e-No: D14-0130 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Joanna Spencer From: Todd Reedy Sent: Tuesday, May 06, 2014 8:06 AM To: Joanna Spencer Subject: RE: 1183 APW Good Morning Joanna, Regarding 1183 Andover Park West: -The 1.5" water service is downstream of a 3" RPPA installed for all services to Building "A" which is now due for testing. The test month for this property is May and the property management company was notified by mail April 30 that the backflow assemblies at this property are due for testing. -The 8" fireline DCDA is also due for testing in the month of May. Have a good day, Todd From: Joanna Spencer Sent: Monday, May 05, 2014 1:40 PM To: Todd Reedy Cc: Joanna Spencer Subject: 1183 APW Good Afternoon Todd, Are their backfiows current? PERMANENT FILE COPY D 1 LF- 0 1 W 1 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0130 DATE: 05/01/2014 PROJECT NAME: SPEC A SITE ADDRESS: 1183 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A AtdC Building Division mi Pupil c Works 7— AYkA Al4A. c ii-v1 Fire Prevention Planning Division Structural Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/06/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 06/03/14 Approved Corrections Required Approved with Conditions kr Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 5/27/2014 ALEXEEV CONSTRUCTION SVCS LLC 0 Washington State Department of Labor & Industries ALEXEEV CONSTRUCTION SVCS LLC Owner or tradesperson ALEXEEV, ALEXANDR A Principals ALEXEEV, ALEXANDR A, MANAGER ALYEKSYEYEV, OLEKSANDR, PARTNER/MEMBER (End: 10/14/2013) Doing business as ALEXEEV CONSTRUCTION SVCS LLC WA UBI No. 602 767 386 PO BOX 731152 PUYALLUP, WA 98373 253-230-4788 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ALEXECS934P9 Effective — expiration 10/29/2007— 10/29/2015 Bond CBIC Bond account no. SF2145 Received by L&I 10/29/2007 Insurance American Fire & Casualty Co Policy no. BKA53456758 $12,000.00 Effective date 10/22/2007 $1, 000, 000.1 https://secure.) ni .wa.g owAerify/D etai I.aspC?UBI=602767386&LIC=ALEXEC S934P9&SAW= 1/3