Loading...
HomeMy WebLinkAboutPermit D14-0176 - NISSIN INTERNATIONAL TRANSPORT - STORAGE RACKSNISSIN INTERNATIONAL TRANSPORT 18436 CASCADE AVE S STE 120 D14-0176 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 7888900030 Permit Number: D14-0176 Address: 18436 CASCADE AVE S 120 Issue Date: 7/2/2014 Permit Expires On: 12/29/2014 Project Name: NISSIN INTERNATIONAL TRANSPORT Owner: Name: EPROPERTY TAX INC DEPT 207 Address: PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: JOSH FRY Phone: (253) 508-0236 Address: 500 SW 16 ST , RENTON, WA, 98057 Contractor: Name: MR RACKS LLC Phone: (425) 207-0058 Address: 500 SW 16 ST, RENTON, WA, 98057 License No: MRRACRL924BN Expiration Date: Lender: Name: N/A ( $5,000 Address: DESCRIPTION OF WORK: BUILDING AND ANCHORING (8) BAYS OF PALLET RACKING Project Valuation: $2,555.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Fees Collected: $257.98 Occupancy per IBC: S-2 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: I hearby certify that I have read and e provisions of law and ordinances gove Wl7 Date: 01 t l 1 d this permit and know the same to be true and correct. All his work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: S©S /, C- Date: 7-2-or-i11 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction docurnents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 9: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 15: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 20: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. b v-4 0 Date Application Accepted: Date Application Expires: l) %*to" i (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 18436 CASCADE AVE S Suite Number: 120 Floor: Tenant Name: NISSIN INTERNATIONAL TRANSPORT USA New Tenant: m Yes ❑ ..No PROPERTY OWNER Name: CBRE Address: 20415 72ND AVE S #210 City: KENT State: WA Zip: 98032 CONTACT PERSON— person receiving all project communication Name: JOSH FRY Address: 500 SW 16TH ST City: RENTON State: WA Zip: 98057 Phone: (253) 508-0236 Fax: Email: JOSH@MRRACKS.COM GENERAL CONTRACTOR INFORMATION Company Name: MR. RACKS LLC Address: 500 SW 16TH ST City: RENTON State: WA Zip: 98057 Phone: (425) 207-0058 Fax: Contr Reg No.: MRRACRL924BN Exp Date: 01/17/2016 Tukwila Business License No.: BUS-0995456 ARCHI I E T OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: BASIL T. KATTULA Engineer Name: BASIL T. KATTULA Address: 21122 126TH AVE SE City: KENT State: WA Zip: 98031 Phone: (206) 857-7303 Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: H:Upplications\Fonns-Applications On Line\2011 Applications\Pennit Application Revised - 8-9-11.docx Revised August 2011 bh Page 1 of 4 BUILDING PERMIT 'INFORMATI4IT— 206-4313670 Valuation of Project (contractor's bid price): $ 2,555 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): BUILDING AND ANCHORING 8 BAYS OF PALLET RACKING Will there be new rack storage? m Yes lmFloar ❑.. No If yes, a separate permit and plan submittal will be required. Provith. AllBuilding Areas in Square rootage Below 12,190 Interior Remodel Addition to ng Structure New Hof Construction per H3C 3'd Floor Floors Accessory Structure Attached Grasp' Detached Garage. Attached Carport Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 21 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If `yes', attach list ofmaterials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Deparhnent. ICApplicstions\Forms-Applications On Line\2011 Applications\Pamit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PE RMATION — 206-�33 }1? Scope of Work (please provide detailed information): BUILDING AND ANCHORING 8 BAYS OF PALLET RACKING Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District 0 ...Tukwila ❑ ...Water District #125 0 ...Water Availability Provided Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. S bmitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) 0 .. Geotechnical Report ❑ ...Traffic Impact Analysis O ...Bond ❑ .. Insurance 0 .. Easement(s) 0 .. Maintenance Agreement(s) 0 ...Hold Harmless — (SAO) 0 ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance O ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards 0 .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut 0 .. Channelization 0 ...Frontage Improvements ❑ .. Pavement Cut 0 .. Trench Excavation 0 ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size .. If WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) O ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billin¢ to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H: Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docr Revised: August 2011 bit Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHOj ED AG . Signature/ � Date: 06/10/2014 Print Name: JOSHUA FRY Day Telephone: (253) 508-0236 Mailing Address: 500 SW 16TH ST RENTON WA 98057 City State Zip H:\ApplicationsFornis-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK I PAID $257.98 D14-0176 Address: 18436 CASCADE AVE S 120 Apn: 7888900030 $257.98 DEVELOPMENT $250.52 PERMIT FEE R000.322.100.00.00 0.00 $149.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $96.92 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $7.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2325 R000.322.900.04.00 0.00 $7.46 $257.98 Date Paid: Tuesday, June 10, 2014 Paid By: MR RACKS Pay Method: CHECK 4219 Printed: Tuesday, June 10, 2014 3:11 PM 1 of 1 INSSP i=TIDf N INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 prolee� Type of Ins ction: Aldir 6i 0,se AA . ADa te Wed: Special Instructions: t 20 1''1 te �P>� Date Wan d: I'S II Tt Requ tI ti &Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: I P I lc f r; ..I�4.i.. or: Date:- l _ lc� SPECTION REQUIR D. Prior to next inspection, fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 444 Andover Park East, Tukwila, Wa. 98188 Project: N«,n Address: 1'l Suite #: �j ( (p riCSC kVA- Special Instructions: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Type of nspection: Contact riCorrections required prior to approval, ,,COMMENTS: A-otok Needs Shift Inspection:. Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: • Occupancy Type Inspector � c- Date: 7-IS- Hrs.. TI $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing. Address Attn: - Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Fireproofing Aggregate% Shotprete Concrete Masonry Asphalt Roofing Piling Steel Soils Wood July 14, 2014 File No. 14-397 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit: Nissin 19436 Cascade Ave. S. Suite 120 D14O17& A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING. NATIONALLY ACCEPTED LABORATORY RECEIVED CITY OF TUKWILA JUL 15 2014 PERMIT CENTER This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and copies of our inspection reports are attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. %Aid atativr--Ni Kimberle Anderson President CC: Mr. Racks -Josh Tel: (425) 881-5812 Fax (425) 881-5441 • 7126 18oth Ave.. NE • P.O. Box 2523 • Redmond, WA 98073 Client: Mr. Racks 500 S.W. 16th St. Renton, WA 98057 Contact: Carey Ferguson Field Report Report #: 26100 Project Number: 14-397 Permit #: D14-0176 Project Name: Nissin Address: 18436 Cascade Ave. S. Suite 120 Inspection Performed: Proprietary Anchors Date: 7/10/2014 Time: Temperature: Inspected installation of wedge anchors for rock system in warehouse area. Base plates and number of anchor per plate conform to note #6 on sheet 2 of plans for racks installed on south wall. Racks along the east wall have base plates that are only 4 1/2" x 3" instead of 8" x 5" and only have one anchor per plate instead of two anchors. Contacted the installer who will contact the engineer for approval of smaller base plate. All anchors have nuts and washers and are in full contact with base plates. Using a calibrated torque wrench, found all anchors to meet or exceed the minimum ft. ib. requirement. All anchor are Simpson Strong Bolt, 1/2" diameter x 4 3/4" as per plan. Distribution: 0 Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner Q Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Matthews, Bill Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden Field Report Report #: 25509 Client: Mr. Racks 500 S.W. 16th St. Renton, WA 98057 Contact: Carey Ferguson Project Number: 14-397 Permit#: D14-0176 Project Name: Nissin Address: 18436 Cascade Ave. S. Suite 120 Inspection Performed: Proprietary Anchors Date: 7/11/2014 Time: Temperature: On site to perform follow up inspection on 7/10/2014, see field report #26100. As noted on previous report, wrong type of base plates were installed for rack system along east wall. Correct base plates were added to conform to engineer's details requirements. Base plates correct size and a minimum two anchors installed per plate, per note #6 on sheet 2 of plans. All anchors correct type and have nuts and washers in full contact with plates. Using a calibrated torque wrench, all anchors are tightened to meet or exceed the minimum ft. lb. requirement. Distribution: Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Matthews, Bill Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden Jon* /4)1/ rMI7WVrn. •• T0;1011o, !)A By erk Debt 6 /201¢ JobNo. 1 034 sect Sreret. SeLth r:vt ,dwuc itturvisis Checked TecsiiA) 4 ,fir» f 1sst oP g r.es epiibeii469 7O nit tom r.hc see: spc flog Ti+o zoo, xrrr cope fi fee tr. 5.3 oP Area 740 I6 nts Ago Vr 0.1-7C3 w>ieu Ira 1. P.1c.0,471 1t for ojtx1 71) Wf pu"1C Cs = CIAO t Fa il 5s)4 Ssst1. 4.09 rm rift me 1L me 400/zeu , w 1• o F'R 51113 Ctes , _ b 7,40Fr, (4i .etta)j bot VT = D,ls t b•o LoNsir t Moo) ,r V- 0.!Dµu 14 . !J, . o . 4,7 Ave ^Pe. * D t. 4- 0, Zt LL stocele LC. = $ ditA«. 4ecx Low pert care p ,t p,o OF 060-f*61 r j IV* A 450 USE 100 cas / Wet. Ftst lb) diCe4 7ypt d : 2, CO6 LAs pto ply we 1,0 /ij — Sheet 1 of 3 VIEWED FOR CODE COMPLIANCE APPROVED JUN 2 7 2014 Ltity of Tukwila alliftiaRIEYDIVISION rAd JSv, Mf . l RAC& V A Co•ijTg ..4' k, : I ttao r a•G7 + 104.e 1rm D. is-46.0 3. 1. tot * D. SJq 4 E rso.7 " sett .41 r r3.itok4 ot = 4 4•-. / Sit 7 41, 37S A V G e : 1.40' T : 8. 31 , vs D.7LA / te�trLrt•i Laao lda TAP Levees o.. q tl • 6,, 257 r e 2o4. dq T", 0.44? , V • 0 431144 • M4kCotrmitir11• 0.7r(1.47..2.239+(10.rr a 3.32k 2-1%s O o. 4-4'4= 1,01/416141 rii446,6ot.r 2 aiEO4E 414 04U C "6*i6EO) pet ex Ault I. '7+A 9 1242 tAt. Pet UGC.-154 Elf -3031 :4 OW spr CiAL l4$pecrtoti+ VA is i io kol h 3", hcif % %44 ) ha = 5" j S = G"r Ca * I.G. L4o.7sl. 474 D. Z9 t.tesc) ok G 20/.. ) .r C.4. Div~ ,p.A6 P. e..t4E o.7rP 1 P•c3k au. 4 c.01 Agee t L 4A c-sermoAAr At s 0. 2,to its mixt r .s ©, itoo kt•�� . ti3.3' (k =1.0) 4" a . r, 3Z ks: 77. a 1. Z0 blol7& • nos E /Lev& At.. r~ s 1. 1" M > P'73 P RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER BASE PLAN Job The Subject Checked Sheet 3 d 3 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0176 DATE: 06/10/14 PROJECT NAME: NISSIN INTERNATIONAL TRANSPORT SITE ADDRESS: 18436 CASCADE AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 1)t- Building Division Public Works AYE �►\• 2/921I`� Fire Prevention Planning Division Structural Permit Coordinator 1 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/12/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 07/10/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MR RACKS LLC Page 1 of 2 CIWashington State Department of Labor & Industries MR RACKS LLC Owner or tradesperson Ferguson, Carey Scott Principals Ferguson, Carey Scott, PARTNER/MEMBER Ferguson, Julie Lynn, PARTNER/MEMBER Ferguson, Carey Scott, AGENT GONSER, BRETT, PARTNER/MEMBER (End: 04/30/2013) MCLENDON, ROBERT, PARTNER/MEMBER (End: 04/30/2013) Doing business as MR RACKS LLC WA UBI No. 602 779 014 500 SW 16TH ST RENTON, WA 98057 425-207-0058 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MRRACRL924BN Effective — expiration 01/03/2008— 01/17/2016 Bond AMERICAN CONTRACTORS INDEM CO Bond account no. 100031015 $12,000.00 Received by L&I Effective date 01/03/2008 12/20/2007 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS1554574031 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602779014&LIC=MRRACRL924BN&SAW= 07/02/2014 178'-94' -ADJACENT TENANT THIS SIDE 72'-lO" OFFICE 24'-6" 0 A 44"X120" 44" X 120" A 44" X 120" 44" X 120" 44" X 120 44" X 120" SPRINKLER RISER 2 99' 4" SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical slPlumbing Gas NOV City of Tukwila BUILDING DIVISION 138'-9 ADJACENT TENANT THIS SIDE REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. I POT r11..:zions win require a new plan submittal . n I may r*,.'ude additional pan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 7 2014 City of BUILDIN ila VISION FILE COPY Penult No. Plan review approval Is subject to errors and omissions. Approval of constru ion documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy andconditions is ono" ledgett Date: City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 02014 PERMIT CENTER bILi 017& co co lop 61 1 00 Cia)EN 0114 N °I14 Iz, :g pig as g EgM $.74 g E--.7c/a s'It to i A r A DRAWN BY: JF SCALE: 1 /8" = 1'- ft DATE: 5-29-14 DRAWING NO: CHECKED BY B. KATTULA "ETEET NO. 1 t OF 2 3'-8" 10' STRUCTURAL NOTES: cg SIDE A-1/21' 1" 3"- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 n FRONT TYPE A RACKS AS NOTED 3" 1 14GA THK. 7/8'15/8" I� f COLUMN DETAIL ALL RACK TYPES r.n 3'-8 SIDE RACK ELEVATIONS SCALE: 1/2" = 1' 1 1/2" ' t 14 GA TlIIC--- " COLUMN STRUT Rl/8" TYP. 1 3/4" 5" 10' o_ U 0 0 0 0 0 0 o 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0' 0 0 0 0' 0 0 0 0 0 0 0 0 Q o 0 irq 0 0 0 0 0 0 o 0 0 0 0 0 0 0 — 0 0 '/� 0 0 �/ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 n , ' \ 03/8" BEAM SECTION 14 GA THK. ASTM A570 GR50 4" BEAM DETAIL FRONT TYPE B RACKS 1/8" <TYP. " T 2 1/2" 1" MP) REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 7 2014 City of Tukwila BUILDING DIVISION 2 1/2" 1 21/2"-'13/4"- 3/16" V <TYP 5/8" 0 HOLE (TYP) 3/8" THICK 3/16" V BASE PLATE ALL RACK TYPES RACK DETAILS SCALE: 3" = 1' 83"THK 1. RACKS ARE MANUFACTURED BY REPUBLIC STORAGE SYSTEMS OF CANTON, OH. OR EQUAL 2. MINIMUM YIELD (Fy) AND ULTIMATE (Fu) STEEL STRENGTHS SHALL BE AS FOLLOWS: (a) BEAMS AND COLUMNS Fy=50ksi Fu=65ksi. (b) BRACING STRUTS Fy=36ksi F 58ksi. (c) BASE PLATES FY=36ksi F1F58ksi. 3. MAXIMUM RACE: LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE: (a) RACKS TYPE A: 1,500 LBS (b) RACKS TYPE B: 2,000 LBS 4. CONCRETE SLAB IS GIVEN AS 5" THICK WITH fc"=2,500 psi. 5. ALLOWABLE SOIL BEARING PRESSURE IS GIVEN AS 1,500psf FOR GRAVITY LOADS. 6. TM -DOWN ANCHORS SHALL BE SIMPSON STRONG BOLT 2 WEDGE ANCHORS. USE: (a) RACK TYPE A & B:TWO (2) 1/2"0 X 4-3/4" ANCHORS WITH A 3" EMBEDMENT PER BASEPLATE SPECIAL INSPECTION IS REQUIRED. 7. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN' AREA SPECIFYING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. 9. ANALYSIS AND DESIGN OF RACK CONFORMS TO THE 2012 IBC SEC 2209, THE 2008 RMI CODE, AND SEC. 15.5.3 OF SEI/ASCE 7-10 USING THE ASD METHOD WHERE: V = 0.67 Cs Ip Ws AND Ip=1.0 (RESTRICTED AREA - NO PUBLIC ALLOWED) Ss=1.409 CS = 2,5 Ca /R AND Ca = 0.3757 FOR THE GIVEN ADDRESS AND SITE CLASS D Sr 0.526 R = 4.0 BRACED DIR. - TRANSVERSE (BRACED) DIR. R = 6.0 UNBRACED DIR. - LONGITUDINAL (MOMENT) DIR. Fa=1.0 FIRE PROTECTION NOTES: 1. SPRINKLER SYSTEM IS .39/S600SQ. FT. SPRINKLER HEAD TEMP IS 286° 2. TYPE OF PRODUCT: CLASS I -IV PALLETS WITH CORRUGATED PACKING MATERIAL, OBSOLETE OFFICE EQUIPMENT (PRINTERS & COMPUTERS), MISC. LUMBER, AND PACKAGING MATERIAL 3. TOP OF STORED PRODUCT NOT TO EXCEED 18'.6", 4. APPROXIMATE CEILING HEIGHT 24 -0 . 1/2" EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQTJIRBS NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. 2. EXTERIOR EXIT DOORS TO BE MARKED PER APPLICABLE CODE FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS BRACING CONNECTION DETAIL 12H 011 co RECEIVED CITY OF TUKWILA JUN 102014 PERMIT CENTER 11100 500 S.W. 16TH STREET, RENTON, WA 98057 425-207-0058 09.4 CNI cri Q ai 0o -oo 00 .< -c) rn ca o v Z00 �gi (,) DRAWN BY: JF SCALE: AS SHOWN DATE: 3-13-14 DRAWING NO: CHECKED BY: B. Kattula SHEET NO. 2 OF 2 SHEETS