HomeMy WebLinkAboutPermit D14-0182 - POTATO CORNER- STORAGE ROOM S404POTATO CORNER
STORAGE RM S404
2800 SOUTHCENTER MALL
D14-0182
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 SouthFenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone:206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
DEVELOPMENT PERMIT
9202470010 Permit Number:
2800 SOUTHCENTER MALL Issue Date:
Permit Expires On:
Project Name: POTATO COINER STORAGE RM S404
D14-0182
8/13/2014
2/9/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD, WA,
92013
CHRISTIAN FALTENBERGER Phone: (206) 246-0423
2800 SOUTHCENTER MALL, TUKWILA,
WA, 98188
EXPRESS CONST COMPANY INC Phone: (206) 230-8500
355 118 AVE SE, STE 100 , BELLEVUE,
WA, 98005
EXPRECC066LP Expiration Date: 7/10/2015
DESCRIPTION OF WORK:
STORAGE RM - S404 - PARTIAL DEMO OF INTERIOR PARTITIONS AND INSTALLATION OF NEW DEMISING WALLS
WITHIN AN EXISTING STORAGE SPACE TO INCLUDE: NEW FILL HEIGHT GWB WALLS, HEALTH CODE APPROVED
COVE BASE, SEALED CONCRETE FLOORS AND NEW LIGHTING AND SWITCHES.
Project Valuation: $10,000.00 Fees Collected: $491.22
Type of Fire Protection: Sprinklers: YES
Fire Alarm: YES
Type of Construction: IIB
Electrical Service Provided by: TUKWILA FIRE SERVICE
Occupancy per IBC: M
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
Permit Center Authorized Signature:
Date:
I hearby certify that I have read and xami ed this permit and know the same to be true and correct. All
provisions of law and ordinances gov rnin: this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree o the co itions attached to this permit., (#:
Signature:
Print Name:
I�
Date: i3--i�
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage
over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic
events. The design and calculations for the anchorage or bracing shall be prepared by a registered
professional engineer licensed in the State of Washington. Periodic special inspection is required during
anchorage of storage racks 8 feet or greater in height.
6: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
11: ***MECHANICAL PERMIT CONDITIONS***
12: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for ,
nonstructural components. ASCE 7, Chapter 13.
13: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall
be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay
bracing.
23: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40
pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-
held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that
its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the
bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC
906.9)
15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and
immediately available for use. These locations shall be along normal paths of travel, unless the fire code
official determines that the hazard posed indicates the need for placement away from normal paths of
travel. (IFC 906.5)
16: Maintain fire extinguisher coverage throughout.
20: Fire protection systems shall be maintained in accordance with the original installation standards for that
system. Required systems shall be extended, altered or augmented as necessary to maintain and continue
protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems
shall be done in accordance with applicable standards. (IFC 901.4)
18: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3)
17: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory
Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire
Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. (City Ordinance No. 2436).
22: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may
require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437)
21: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE FINAL
0409 FRAMING
0406 SUSPENDED CEILING
Site Address: 2600 SOUTHCENTER MALL
Tenant Name: POTATO CORNER - STORAGE RM S404
PROPERTY OWNER
Name: WESTFIELD CORPORATION
Address: 2800 SOUTHCENTER MALL
City: TUKWILA State: WA
Zip: 98188
CONTACT PERSON - person receiving al project
communication
Name: CHRISTIAN FALTENBERGER
Address: 2800 SOUTHCENTER MALL
City: TUKWILA State: WA Zip: 98188
Phone: (206) 246-0423 Fax:
Email: CFALTENBERGER@US.WESTFIELD.COI i
GENERAL CONTRACTOR INFORMATION
Company Name:
Address:
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
ofiifrY
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 9202470010
Suite Number: S404 Floor: 1
New Tenant: ❑ Yes §47..No
ARCHITECT OF RECORD
Company Name: JJW ARCHITECTS & PLANNERS
Architect Name: JAMES WASSERMAN
Address: 5628 AIRPORT WAY SOUTH, SUITE 112
City: SEATTLE State: WA Zip: 98108
Phone: (206) 420-2242 Fax:
Email: JWASSERMAN@JJWARCH.COM
ENGINEER OF RECORD
Company Name:
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name:
Address:
City: State: Zip:
HAAppiicationsTorms-Applications On Line \2011 ApplicationsU'ermit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 1 of 4
BUILDING PERMIT INFORMATION - 206-431-3670
Valuation of Project (contractor's bid price): $ 10,000 Existing Building Valuation: $ 183,000,000
Describe the scope of work (please provide detailed information):
PARTIAL DEMOLITION OF INTERIOR PARTITIONS AND INSTALLATION FO NEW DEMISING WALLS WITHIN AN
EXISTING STORAGE SPACE TO INCLUDE: NEW FILL HEIGHT GWB WALLS, HEALTH CODE APPROVED COVE
BASE, SEALED CONCRETE FLOORS, AND NEW LIGHTING AND SWITCHES.
ELECTRIC WORK AND SPRINKLER MODIFICATIONS TO BE PERMITTED BY CONTRACTOR UNDER SEPARATE
PERMIT.
Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
I' Floor
190
190
IIB
S
2nd Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:1Applications\Forms-Applications On Line 1201 I Applications'Permit Application Revised - 8.9-11.docx
Revised: August 2011
bh
Page 2 of 4
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
5628 AIRPORT WAY SUITE 112
Day Telephone:
SEATTLE
City
Date: 06/13/2014
(206) 420-2242
WA 98108
Stye zip
x:\AppliatiomlForms-Appliations On Line12011 ApplicationsVPenmt. Application Revised - 8-9-11.docx
Revised August 2011
bit
Page4of4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
( ACCOUNT QUANTITY
PAID
$305.12
D14-0182 Address: 2800 SOUTHCENTER MALL Apn: 9202470010
$305.12
DEVELOPMENT
$290.80
PERMIT FEE
R000.322.100.00.00
0.00
$286.30
WASHINGTON STATE SURCHARGE
8640.237.114
0.00
$4.50
TECHNOLOGY FEE
$14.32
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2851
R000.322.900.04.00
0.00
$14.32
$305.12
Date Paid: Wednesday, August 13, 2014
Paid By: EXPRESS CONSTRUCTION
Pay Method: CHECK 055772
Printed: Wednesday, August 13, 2014 8:41 AM 1 of 1
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
I ACCOUNT
QUANTITY PAID
D14-0182 Address: 2800 SOUTHCENTER MALL Apn: 9202470010
$186.10
DEVELOPMENT
$186.10
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R2364
R000.345.830.00.00
0.00
$186.10
$186.10
Date Paid: Friday, June 13, 2014
Paid By: JJW ARCHITECTS & PLANNERS
Pay Method: CHECK 2976
Printed: Friday, June 13, 2014 12:18 PM 1 of 1
c)-'`
INSPECTION RECORD
Retain a copy with permit
D o(8a
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 431-2451
Proj t:
Igo1�;0CbR IZ
Type o sp cuA t✓
l
Addres :
D-�oo Se AA i I
Date Called:
Specia Instructions:
Snot -AO R.An
z4 0L 4
Date W ed:
��
t�-�
/`� a.m.
Requester:
Phone No:
Approved per applicable codes.
EjCorrections required prior to approval.
COMMENTS:
iP
Dat 2
y
SPECTION FEE REQU1I D. Prior to next inspection, fee must be
at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT N
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 431-2451
Pr ct:
ri`rCO c.2r4eR
Ty Inspection:
r Pcr11 nf�
Addr ssnn AA
Date Called:
tractions:
Special Instructions:
S` -6 5k°i
/
Date Wante _' r e 11
(�
Requester:
-e- f i 6
1,171(e,NO: -t
a ......
1 o
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Ins $ - or:
Date: z r� ,
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION tECORD
Retain a copy with permit
INSPECTION NUMBER
b/V O/v z
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project: *ef4.4 4-#-",4 `
Type of In pecti n:
Address:
Suite #: Z' SC nr,a- //
016 w y
Contact Person:
Special Instructions:
Phone No.:
?Approved per applicable codes.
I I Corrections required prior to approval.
COMMENTS:
P--74 /Vzie
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
:
Permits:
Occupancy Ty;
Inspector
i
5- 3
Date: Gl` G �� �%
Hrs.: %
(�
n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. CaII to schedule a reinspection.
Billing Address
Attn:
Address:
Company Name:
City:
State:
Zip:
Word/Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
JIPERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D14-0182 DATE: 06/13/2014
PROJECT NAME: POTATO CORNER - STORAGE ROOM S404
SITE ADDRESS: 2800 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
fry A1L)C (_t7 ►�
Building Division El
MS t/>& ( 1y
Public Works
4tAx-
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 06/17/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
El
(corrections entered in Reviews)
DUE DATE: 07/15/14
Approved with Conditions N
Denied
(ie: Zoning Issues)
El
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
EXPRESS CONST COMPANY IN
Page 1 of 2
Washington State Department of
Labor & Industries
EXPRESS CONST COMPANY INC
Owner or tradesperson
LARSEN, GRANT R
Principals
LARSEN, GRANT R, PRESIDENT
LOWRY, DAVID H, VICE PRESIDENT
LOWERY, BARBARA, TREASURER
Doing business as
EXPRESS CONST COMPANY INC
WA UBI No.
601 547 506
355 - 118TH AVE SE
BELLEVUE, WA98005
206-230-8500
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
EXPRECC066LP
Effective — expiration
06/17/1994— 07/10/2015
Bond
USF&G CO
Bond account no.
TC6142
Received by L&I
05/21/2004
Insurance
Scottsdale Ins Co
Policy no.
bcs0030414
Received by L&I
05/22/2014
$12,000.00
Effective date
05/24/2004
Expiration date
Until Canceled
$1,000,000.00
Effective date
06/15/2013
Expiration date
06/15/2015
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601547506&LIC=EXPRECC066LP&SAW= 08/13/2014
Landlord Work - Potato Corner
Space S404
2600 SOUTHCENTER MALL
TUKWILA, WA 98188
PERMIT SET - 06.13.2014
SHEET INDEX
VICINITY MAP
CODE INFORMATION
ARCHITECTURAL
G-0.0 COVER SHEET
G-0.1 EXITING PLANS & CODE ANALYSIS
G-0.2 GENERAL NOTES & WALL TYPES
AD-2.0 DEMOLITION PLAN AND RCP
A-2.0 FLOOR PLAN & RCP
PROJECT DESCRIPTION
DEMOLITION OF INTERIOR PARTITIONS AND INSTALLATION OF NEW DEMISING WALLS WITHIN AN
EXISTING STORAGE SPACE TO INCLUDE: NEW FULL HEIGHT GWB WALLS, NON -POROUS PLASTIC
COVE BASE, AND SEALED CONCRETE FLOOR.
ELECTRIC WORK AND SPRINKLER MODIFICATIONS TO BE PERMITTED BY CONTRACTOR UNDER
SEPARATE PERMIT.
PROJECT TEAM
ARCHITECT
JJW ARCHITECTS AND PLANNERS
5628 AIRPORT WAY SOUTH, SUITE 112
SEATTLE, WA 98108
P: 206.420.2242
F: 206.260.9595
ATTN: JEFF WASSERMAN
E: JWASSERMAN@JJWARCH.COM
PROPERTY MANAGEMENT
WESTFIELD CORPORATION
2800 SOUTHCENTER MALL
TUKWILA, WA 98188
P: 206.246.0423
ATTN: CHRISTIAN FALTENBERGER
E: CFALTENBERGER@US.WESTFIELD.COM
NOT TO SCALE
ZONING
TUC, TUKWILA URBAN CENTER
APPLICABLE CODES
2012 INTERNATIONAL BUILDING CODE
2012 UNIFORM PLUMBING CODE
2012 INTERNATIONAL MECHANICAL CODE
CONSTRUCTION TYPE
EXISTING BUILDING - TYPE IIB CONSTRUCTION
FULLY SPRINKLED (PER NAFPA 13)
2012 NATIONAL ELECTRICAL CODE
2012 INTERNATIONAL FIRE CODE
WASHINGTON STATE ENERGY CODE
NEW CONSTRUCTION - TYPE IIB CONSTRUCTION
OCCUPANCY CLASSIFICATION
STORAGE (S): 190 SF
PARKING
NO CHANGE TO EXISTING
FILE COPY
Permit Na b IMOLe2
REVIEWED FOR
ODE COMPLIANCE
APPROVED
JUN 3 0 2014
A-7 vie -
City of Tukwila
BUILDING DIVISION
E
0
L
cti
E
U
SYMBOLS
(ARCHITECTURAL) - (ALL SYMBOLS ARE NOT NECESSARILY USED)
MALL KEY PLAN
TENANT
PT 1
CPT-1
ROOM NUMBER
DOOR NUMBER
WINDOW TYPES
KEY TO WALL FINISH SCHEDULE
KEY TO FLOOR FINISH SCHEDULE
CEILING FINISH
CEILING HEIGHT
KEY TO CEILING FINISH SCHEDULE
KEY TO WALL TYPES
COLUMN CENTERLINE
I in
SEE 2/A-1
REFER TO
DETAIL NUMBE
SHEET NUMBE
SECTION MARK
ENLARGED PLAN/
DETAIL REFERENCE
ELEVATION KEY
REVISION CLOUD WITH
REVISION DELTA TAG
HOLD CLOUD
>a
,,,,,,
EARTH
GRAVEL/BALLAST
SAND
CONCRETE
PRECAST CONCRET
STEEL
GYM FLOOR
WOOD (CONTINUOUS BLOCKING)
WOOD (NON -CONTINUOS BLOCKING)
WOOD (TRIM/FINISH)
GLASS
STONE
R
No changessh
r
ISIONS
II be made to the scope
of work with
Tukwila
ut prior approval of
: uilding Division.
CTE: Revisions wil require a new plan submittal
and may include additional plan review fees.
SHINGLES
CONCRETE MASONRY UNIT
BRICK VENEER
METAL STUDS
PRECAST (IN PLAN)
STEEL (LARGE SCALE)
PLYWOOD (LARGE SCALE)
GYPSUM WALL BOARD
(LARGE SCALE)
BATT INSULATION
RIGID INSULATION
PROTECTION BOARD
CARPET (LARGE SCALE)
ACOUSTICAL TILE (LARGE SCALE)
TILE (LARGE SCALE)
SEPARATE PkRMIT,
REQUIRED FOR:
iiierli chanicai
Iectrical
Plumbing
eGas Piping
City of Tukwila
BUILDING DIVISION
NOT TO SCALE
0 0
Plan review approval Is subject to errors and omissions.
Approvel of cnnst uctina vganta does not authorizo
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and r+ ' ons; acknowledged:
Br
Date: f—t
City of Tukwila
BUILDING DIVISION
CI 0 ED ❑ 0
n n
n n
PROJECT AREA
RECEIVED
CITY OF TUKWILA
JUN 1 3 2014
PERMIT CENTER
OPERA11ON
a�Ar
DIW-01��
COVER
CD
W Z W• U
0
U w
Q -�
O 2
W
1--
ft Z
O w
0 I—
▪ D
O 0
J (n
O
Z O
Q
DATE
ISSUE
06.13.2014
PERMIT SET
G-0.0
2014-20-00
E
El
J
EXISTING EXIT
34" CLEAR
170 OCC. ALLOWED
3 OCC. ACTUAL
EXISTING EXITING PLAN
SCALE: 1/4" = 1'-0
L_
OCCUPANCY CLASSIFICATION
ROOM CLASSIFICATION GROSS SF SF/PERSON OCC.
EXIST STORAGE ROOM S404 STORAGE 1020 SF 300 SF/PERSON 3
NEW STORAGE ROOM S404 STORAGE 880 SF 300 SF/PERSON 2
NEW DEMISED STORAGE SPACE STORAGE 190 SF 300 SF/PERSON 1
CAPACITY OF EGRESS (TABLE 1005.1)
ALL EXIT DOORS SHALL BE PROVIDED WITH PANIC HARDWARE
EGRESS CAPACITY ACTUAL FOR DOORS (1)34" / 0.2 = 170 PEOPLE
MINIMUM NUMBER OF EXITS (TABLE 1021.1)
REQUIRED EXITS
ACTUAL EXITS
RATED WALL
1 EACH
1 EACH
XxXXXxXXXXXXXXXXXXXXXXXXXXX
—- - MI NM
L
NEW EXIT
34" CLEAR
170 OCC. ALLOWED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 3 0 2014
City of Tukwila
BUILDING DIVISION
,
A
A
A
44
V
r,
EXISTING EXIT
34" CLEAR
170 OCC. ALLOWED
7
L
A
RECEIVED
CITY OF TUKWILA
JUN132014
NEW EXITING PLAN p114-1) ( 8
PERMIT CENTER
SCALE: 1 /4' = 1'-0'
1 OCC. ACTUAL
2 OCC. ACTUAL
JJW Architects and Planners
N
a)
CO co
(1)
O
� O
m
Q
O
Q
as
COco
CJ)
V )
V
>-
Zci
r)
w
0
0
0
U)
z
-I
0
0
z
w
LANDLORD WORK - POTATO CORNER
V J
w
0
0
J
J
2
moo
z co
wo
0 <
DQ
O=
2
N I —
DATE
06.13.2014
ISSUE
PERMIT SET
G-O.1
2014-20-00
GENERAL NOTES
ARCHITECTURAL:
1 ALL INTERIOR WALLS ARE TO BE COMPLETED TO LEVEL 4 FINISH;
TAPED, MUDDED, SANDED, AND ONE COAT OF LATEX PRIMER.
FINISHED WITH 2 COATS OF WHITE ENAMEL PAINT.
2. ALL ROUGH OPENINGS FOR DOORS TO BE LOCATED 6" AWAY
FROM CLOSEST ADJACENT WALL.
3. FIRE SPRINKLER SYSTEM IS TO BE MODIFIED BY DESIGN/BUILD
FOR THE NEW SPACE.
. EXISTING CONCRETE FLOOR TO BE CLEANED, GROUND SMOOTH
AND SEALED.
5. NEW HOLLOW METAL DOOR AND FRAME TO BE 1-HOUR FIRE
RATED WITH LCN MODEL DOOR CLOSER AND CONTINUOUS
GEARED HINGES. DOOR AND FRAME TO BE FIELD PAINTED AFTER
INSTALLATION TO MATCH EXISTING.
ELECTRICAL:
1. CONTRACTOR SHALL FURNISH AND INSTALL (1) 50 AMP, 120/208V,
3 PHASE, 4 WIRE SERVICE IN A MIN. 1" CONDUIT W/ CONDUCTORS
FROM THE NEAREST LL ELECTIRCAL SERVICE TO POC WITHIN
ALLOCATED SPACE IN S404. INCLUDE NEW LIGHTING AND LIGHT
SWITCH.
2. ELECTRICAL WORK TO BE SUBMITTED UNDER SEPARATE PERMIT
BY CONTRACTOR.
U
11 O (o
c�0
4 c.0�
Q Q COca
CO 0 0
C N N N .�
-)lf)U) Q N
EXIST. CEILING DECK
5/8" GYP. WALLBOARD UP
TO EXIST. CEILING DECK
3 5/8" METAL
STUDS
6" NON -POROUS RUBBER BASE -
BLACK BY ROPPE OR APPROVED
EQUAL
INTERIOR PARTITIONS
3 5/8" MTL. STUD WITH 5/8" GYP.
WALLBOARD BOTH SIDES
WALL TYPES
1 SCALE: 1/2" = 1'-0"
bli+w
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 3 0 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 1 3 2014
GENERAL NOTES & WALL TYPES
LL (C%)
W W
Z U
�
O0_
• cf)
O
I—
Q
O 2
L11 �
• Z 00
O w a)
UQ
0 I
O OJ
O Y
Z
J N I —
DATE
ISSUE
06.13.2014
PERMIT SET
PERMIT CENTER
G-O.2
2014-20-00
6:' 3'-4"
DEMO EXIST. METAL STUD AND
WIRE PARTITIONS AND DOORS AND
SALVAGE AS NECESSARY FOR
REINSTALLATION PER SHEET A-2.0
-111.•
DEMO EXIST. WALL AREA FOR
INSTALLATION OF NEW DOORWAY
DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
1
EXTENT OF WORK
GENERAL DEMO NOTES
1. REMOVE AND SALVAGE EXISTING METAL STUD AND
WIRE PARTITIONS FOR REINSTALLATION PER SHEET
A-2.0
2. REMOVE AND SALVAGE ALL EXISTING INTERIOR
DOORS. VERIFY WITH CLIENT.
3. CLEAN AND PREP CONC. FLOOR IN PROJECT AREA
FOR SEALANT FINISH.
4. DIMENSIONS SHOWN ARE TO PARTITION
CENTERLINES (TENANT LEASE LINES) .
5. ALL NEW GYP BOARD WITHIN THE TENANT SPACE IS
TO BE MUDDED, SANDED, AND ONE COAT OF PRIMER
IS TO BE APPLIED. PAINT 2 COATS, FINISHED PAINT -
WHITE ENAMEL.
- x -
REMOVE EXISTING LIGHT FIXTURES IN PROJECT
SCOPE AREA AND SALVAGE FOR REINSTALLATION
IN NEW LOCATIONS PER SHEET A-2.0
DEMO WALLS BELOW
PER 1/AD-2.0
1101,
•
DEMOLITION RCP
2SCALE: 1 /4" = 1t)
'-0"
rommosill
EXTENT
F WORK
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 3 0 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 1 3 2014
PERMIT CENTER
r
a)
0
00 CO
>+
(la co
47
1
c
LO U)
E
S
U
L
co
co
cn
a)
co
a)
0
U
0
z
z
^J
0
z
0
J
0
W
0
LANDLORD WORK - POTATO CORNER
O
U)
W
U
a
J
J
2
• co
w co
W O)
U <
D Q
O —I
coo o�
F-
DATE
ISSUE
06.13.2014
PERMIT SET
AD-2.O
2014-20-00
GWB WALLS TO RUN \
UP TO BOTTOM OF
STRUCTURE
TAPED, SANDED, AND
FINISHED W/ WHITE
ENAMEL PAINT
Xl KXXXXXXXX
EXISTING METAL STUDS/WIRE
PARTITIONS AND DOORS TO REMAIN.
REPAIR METAL STUD AND WIRE
WALL UP TO EDGE OF NEW GWB
WALL.
8" BLACK PLASTIC NON -POROUS
COVE BASE AT INTERIOR OF
EACH GWB WALL, TYP.
EXIST. CONC. FLOOR TO
BE CLEANED AND SEALED
NEW 50 AMP 120/208V, 3
PHASE, 4 WIRE SERVICE
NEW ACCESS DOOR TO
MATCH EXIST.
1
KYVA
• ♦♦♦ XXXXXXXXXXX>
•
SALVAGED WIRE WALL
AND DOOR RE -INSTALLED
IN NEW LOCATION ;►
•
EXTENT OF WORK
14'-0"
5'-0"
FLOOR PLAN
EXIST. G
ELEC. Pf
B WALL AND
EL TO REMAIN
i
XXXXXXXX
EQ.
XX
EQ.
EmolO
3C>QQ(XXXXXX>4
1
1
KXXXXXXXX,
RE INSTALL LIGHT FIXTURES & SUSPEND
FROM CEILING STRUCTURE PER EXISTING
EXTENT OF WORK
CREFLECTED CEILING PLAN
SCALE: 1/4" = 1-0"
XXXXXXXXXXXXXXX ♦ X>
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 3 0 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 1 3 2014
N
a)
U)
L
+ r
CO
• co
cla co
Q
O
Q
Q a)
co
�f) co
FLOOR PLAN & RCP
v J
w w
Z V
� Q
00_
O co
0
Q
O 2
LLJ
Et Z
O w
Ifl I-
O 0
O
Z
J N
CO
CO
CO
Q
Q
J
i
DATE
ISSUE
06.13.2014
PERMIT SET
SCALE: 1/4" = 1'-0"
PERMIT CENTER
A-2.O
2014-20-00