Loading...
HomeMy WebLinkAboutPermit D14-0195 - INTERURBAN PUMP STATION - REROOFINTERURBAN PUMP STATION 13980 INTERURBAN AVE S D14-0195 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0002800006 Permit Number: D14-0195 13980 INTERURBAN AVE S Project Name: INTERURBAN PUMP STATION Issue Date: 7/8/2014 Permit Expires On: 1/4/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD, TUKWILA, WA, 98188 DAN JOHNNSON Phone: (253) 863-4455 13105 HOUSTON RD E , SUMNER, WA, 98390 WAYNE'S ROOFING INC 13105 HOUSTON RD , SUMNER, WA, 98390 WAYNESR205Q5 Phone: (253) 863-4455 Expiration Date: 5/2/2015 DESCRIPTION OF WORK: REMOVE EXISTING ROOFING TO CONCRETE DECK. REPLACE WITH NEW INSULATIONTED SBS MODIFIED ROOF SYSTEM. Project Valuation: $58,059.00 Fees Collected: $1,838.20 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Occupancy per IBC: U Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 0'1 Alw I hearby certify that I have read and ned this permit and know the same to be true and correct. All provisions of law and ordinances go : this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction • the performance of work. I am authorized to sign and obtain this development permit and`: to t • - conditi • ns attached to this permit. Signature: Print Name: Date: 7 1 Li el- JG /-_14.4i14 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: If a propane fueled asphalt kettle is used, a LP -Gas Permit must be obtained from the Tukwila Fire Marshal's Office, 444 Andover Park East, Tukwila WA 98188, 206-575-4407. 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 12: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 13: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0612 EXT ROOFING INSUL 0103 PRE-REROOF CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov rmit No.' V 1 ProBuildingject No. Pe Date Application epted: 1 Date Application EAccxpires: (For'ofce us. only) 01'1.5 CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 13980 Interurban Ave S Tenant Name: Interurban Pump Station PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON - - person receiving all project communication Name: Dan Johnson Address: 13105 Houston rd E City: Sumner State: wa Zip: 98390 Phone: (253) 863-4455 Fax: (253) 863-8311 Email: dan@waynesroofing.com GENERAL CONTRACTOR INFORMATION Company Name: Wayne's Roofing Inc Address: 13105 houston Rd E City: Sumner State: WA Zip: 98390 Phone: (253) 863-4455 Fax: Contr Reg No.: WAYNESR205Q5 Exp Date: 05/15/2014 Tukwila Business License No.: Olt\ t„Itri 01 King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: El Yes I ..No ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: H \ Applications \Forms -Applications On Line \2011 Applications\Permit Application Revised - 8-9-11. docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION'— 2U6-431-3670 Valuation of Project (contractor's bid price): $ 58,059 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Remove existing roofing to concrete deck. Replace with new insulated SBS Modified roof system. Will there be new rack storage? 0 Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Squ e Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 n Floor 2' Floor 3`4 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? D Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No 1f "yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications \Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mike_ Try 'kJ Mailing Address: 13105 Houston Rd E Date: 06 - 20- /y Day Telephone: (253) 606-7796 Sumner WA 98390 City State Zip H:\Applications\Fontta-Applications On Line\2011 Applications\Pemut Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS p+eiNl _ ACCOUNT QUANTITY PAID $1,838.20 D14-01 5 Address: 13980 INTERURBAN AVE S Apn: 0002800006 $1,838.20 DEVELOPMENT $1,784.27 PERMIT FEE R000.322.100.00.00 0.00 $1,078.65 PLAN CHECK FEE R000.345.830.00.00 0.00 $701.12 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $53.93 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2430 R000.322.900.04.00 0.00 $53.93 $1,838.20 Date Paid: Friday, June 20, 2014 Paid By: WAYNE'S ROOFING, INC. Pay Method: CHECK 8426 Printed: Friday, June 20, 2014 1:57 PM 1 of 1 SYSTEMS 41-4 INSPECTION N0. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., 6100, Tukwila. WA 98188 (206) 431-367 Permit inspection Request Line (206) 438-9350 'Project: Jra/�n puM! Type of inswctiopi fl k i4) 6U , et l A " AAJAL : sd�{fti/6/N Date Called: Instructions: Date Wanted: t eK.2 Pam Requester: Phone No: Approved per applicable codes. rrections required prior to approval. COMMENT: ref M f LD.1111 Pif P Date: -IS ON ON FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS4tINPERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: -C1v f.E +V Pam S ' • sAr Type pf Inspec 'on: t f 4 AM LAddress• 135%0 .i Stut A-ril Ned: Dategut Special Instructions: Date Wanted: - 2 1 - / P-m. Requester: Phone No: /' roved per applicable codes. Corrections required prior to approval. C6MMENTS: Po on(e 6( s ;—. AJ e i v4J'r l l.e-SE-'Lt u (Date: 2 1S REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd, Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj `` ( �. Z<< t�\,u -1�141 ; Type of Inaction: 1� 1 NJA i, Addre : �, Scate S �. ? �P ✓l Li /r'! Called: kt j Special Instructions: RJR Date W ted: 4r_' Requester: (1vl{ 6 IQ D d - i iA/ (= one o: LR �j QApproved per applicable codes. ..Corrections required prior to approval. COMMENTS: 'v,) - L-4-A ��e -e f k Date: SPECTION FEE REQU)( ED. Prior to next{ inspection. fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 IProj fvt_wtType of Inspection: _ Aids f� U��c )1361. N Date Caiied: Sptec cia In trucction. tRquetf, bate Wan d: a.m. Q,Octe:'V c M14.. .3 L( L 1Approved per applicable codes. Corrections required prior to approval. COMMENTS: nspe;• r: Data. , Lf REINS • ECTION FEE REQUIRED. Prior to nkxt inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. ((Nall to schedule reinspection. Roofing Guarantee Whereas, WAYNE'S ROOFING, INCORPORATED, of Sumner, Washington, herein called "the Contractor," has completed application of the following roof Owner: KJtp9 County Wastewater Treatment DI,11S1an Address of Owner: 201 Sou t Sb Room 1150.1, "Seattle, WA 98104 Type and Name of Building: 1iurban:' Location 139110httentrbaa Avenue South, Tukwila, WA 98168 Area 'ofRoof 2,a ua►is Feet Date ofCompletion: August 'fat 2014 Dale Guarantee Expires August 12, 20.18 Whereas, at the inception of such work the Contractor agreed to guarantee the aforesaid roof against fault, materials yo�r,,workmanship for a limited period and subject to the conditions herein set forth: now, The f , the Contractorhereby Guaiwuees, subject to the conditions herein set forth, that during a period of TWO (Z) years from the date of completion of said roof* will, at its own cost sand expertte, make or cause to be made such repairs to said roof and composition, flashing resulting solely from faults' or defects in materials or workmanship applied by or through the Contractor as may be necessary to maintain saidroof in watertight condition. This guarantee is made subject to the follOWhng: conditions: 1. Specifically excluded from this guarantee is any and all damage to said rood the building or contents caused by the acts or omissions of other trades or contractors; lightning, windstorm, hailstorm, or other unusual; phenomena of the elements; foundation settlement; failure :or; cracking of the roof deck; defbas: or failure:ofmatatial used as a roof base over which the roof is applied. faulty oonstnusion of parapet wall, copings, chimneys, skylights, vents, supports ter otherpe is of° building vapor condensation beneath the roof; penetrations for pitch boxes; or fire. If the roof is damaged by mason of any of the foe cooithe ng this shW thereupon become mill and void for the balance of the guarantee period unless such damage is repaired by the Contractor at the expense of the Party requesting such maim. 2. The Contractor is not liable for consequential damages to the building or contents resuhing from any defects m said roof or composition flashing. 3 No work shall be done on said roof, including, but without limitation, .work in connection with flues, vents, drains, sign braces, railing, platforms or other equipment fastened to or set on the roof; and no. repairs or alterations shall be made to said root unless the Contractor shall be first notified, shall be given the opportunity to, make the necessary meting application recommendations with respect thereto, and such recommendationsare complied with. Failure to observe this condition shall render this guarantee null and void: The Contractor shall be paid for time and material expended in making reconunendations or repairs occasioned by the work of others on said roof. 4. This guaranteesisal become null and void if the roof is used as a promenade or work deck or is sprayed or flooded, unless such use was originally specified and the specification is noted in paragraph 8 below. Areas that pond water shall not be covered by this guarantee. S. This guarantee shall not be or become effective unless and until the Contractor has been paid in full for said goof hi accordance with the agreement pursuer° to which such roof was applied. 6. This guarantee shall become null and void unless the Contractor is pzunptiy notified of the alleged defect in materials or workmanship and provided an opportunity to inspect the roof T. This guarantee is in lieu of all other guarantees or warranties, express or implied g. Additional ads or exclusions: includes new sheet metal ""fleshings, skylight, and other related work installed with, new roof system as a portion of roofing contractor's wcrk,scope. In Witness Whereof this histmmenthes been duly executed this?Sli1l day off, RECEIVED WAYNE'S ROOFING, INC. 131es► CITY. OF TUKWILA JAN 12 2015 PERMIT CENTER BY Dl�l-0 fR5 NINE javi SOPREMA' Dear Building Owner: Thank you for choosing Soprema for your roofing needs! Enclosed are your original Soprema Warranty Documents. In order for the warranty document to be valid a copy must be signed and returned to Soprema within three (3) months of its issue date. There are two (2) copies provided for your signature, one original for you to retain for your records and one copy that is highlighted to be returned to Soprema in the enclosed envelope. Soprema's products are time proven for quality, durability and reliability. If at any time you experience any problems or have any questions, please contact our Warranty Department at 800- 356-3521, Monday through Friday from 8:00 a.m. to 5:00 p.m., Eastern Time. For your convenience we have also included in this packet copies of the following: Roof Care & Maintenance Guide Warranty Claim Procedure Warranty Claim Form Warranty Transfer Procedure Warranty Transfer Form Roof Hatch Sign Sincerely, SOPREMA, INC. Patricia Johnson Warranty Supervisor SOPREMA, INC. 310 Quadral Drive • Wadsworth, Ohio 44281 • Phone (330) 334-0066. 1-800-356-3521 • FAX (330) 334-4289 • WWW.SOPREMA.US ( %I %I y`! /) %I /?I --D2 --61 (95 Warranty No.: 101-011568 Platinum NDL Roof Warranty Building Name: Interurban Pump Station Building Address: 13980 Interurban Avenue South, Tukwila, WA 98168 Roof Section: N/A Owner Name: King County Wastewater Treatment Division Owner Address: 201 South Jackson Street, Room 501, Seattle, WA 98104 Contractor: Wayne's Roofing, 13105 Houston Road, Sumter, WA 98390 Total Squares: 32 Roof Material: 20.42 Flashing Material: 20.47 Term of Warranty: 10 Years Warranty Start Date: 08.13.2014 Warranty End Date: 08.13.2024 Express Warranty SOPREMA, Inc,, an Ohio corporation, warrants to you that your SOPREMA roof system will remain watertight for the full term of this warranty, This warranty is made subject to all the terms, conditions, and limitations set forth below. Reporting Claims To report a claim, follow the procedure set forth in Form 900 - Warranty Claim Procedure. Remedy When you make a valid claim, SOPREMA will provide the labor and material necessary to return the roof system to a watertight condition. NOTICES THE WARRANTY EXPRESSED IN. THIS DOCUMENT SUPERSEDES AND IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. THE ABOVE -STATED REMEDY IS YOUR SOLE AND EXCLUSIVE REMEDY AGAINST SOPREMA. IN NO EVENT IS SOPREMA LIABLE TO YOU OR ANY OCCUPANT OF THE BUILDING FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, OR OTHER SIMILAR DAMAGES. This warranty document includes all of the following: 1. The Terms, Conditions and Limitations printed on the reverse. 2. Form 900 — Warranty Claim Procedure. 3. Form 901 — Care and Maintenance Guide. 4. Any rider referred to below. This warranty is not valid until activated, To be activated, itmust be signed by Owner and retumed to SOPREMA within three months after the warranty start date. Until activated, the warranty is not binding against eithsr party. Owner: k.1 vel v By: By: Name: Richard Voyer Name: ►..� Title: Vice President/General Manager Title: Lj / Date: 08.13.2014 Date: �^, Riders issued at time of this warranty: 20-Year NDL to include membrane. membrane flashing, roof insulation, C%ll � cover board, and all SOPREMA suoplied rda0oroved roofing accessories. vocc000000dcm000m0000nwocxxoocxxx 19 l� 'NI (Form 101) (07/2013) i.7-1 I— /i-cR-a-a--csr-a--a-a-a--c\r-a-a--a--a-c-\r-c-\-e--a---ar-a--a-V r Warranty No.: 101-011568 CARE AND MAINTENANCE GUIDE A routine Care and Maintenance program Is fundamental to the Tong -term performance of your roofing or waterproofing system. You, as the Owner, are responsible for ensuring that a minimum of two documented Care and Maintenance inspections are conducted and recorded each year. For areas that are concealed from direct view, record any observable conditions that may have an adverse affect on the roofing or waterproofing system. Required Care and Maintenance: A Care and Maintenance log, or similar record, is the minimum requirement to document care and maintenance. See the reverse side of this document for an example of a Care and Maintenance Log. The following activities are required: • Date of Inspection: The minimum requirement is two times per year. • Inspected by: Name and signature. • Conditions: Record observations of accessible roofing or waterproofing membranes and membrane fleshings at all edges, terminations and penetrations. Record observations of any other conditions that may have an effect on the roofing or waterproofing system. • Leaks: Document ail roofing or waterproofing system leaks. Refer to Form 900 — Warranty Claim Procedure. • Repairs and Modifications: Date of all work, and the individual or company who completed work that may have an effect on the roofing or waterproofing system. When to complete Care and Maintenance: You must inspect your roofing or waterproofing system at least two times per year, ideally in the spring and fall. Be sure to document each date the roofing or waterproofing system is accessed for the purposes of an inspection, maintenance or other work that may have an effect on the roofing or waterproofing system. It is recommended that you inspect and document conditions after all severe exposures, such as seismic events, flooding, high winds, or excessive snow, ice, rain or hail. It is also recommended that you inspect and document conditions during and after equipment maintenance and adjacent building work. Limit Access: For areas of the roofing or waterproofing system not designated for traffic, we recommend you limit access to authorized personnel only and require all individuals to register or sign in. It is good practice to post a sign at all access points that includes the following statement: 'STOP. ACCESS RESTRICTED TO AUTHORIZED PERSONNEL ONLY.` At your request, SOPREMA will provide you with signs. Care and Maintenance Inspections: Record your observations of the roofing or waterproofing system as well as conditions at all edges, terminations and penetrations. Record conditions for evidence of physical damage, displacement, open membrane laps, accumulation of debris, or other conditions that may have an effect on the roofing or waterproofing system. Record the condition of adjacent walls, sealants, coatings, equipment, sheet metal fleshings, pipes, pitch pans, drains, scuppers, pavers, garden roof components, and any unusual exposures or conditions that may have an effect on the roofing or waterproofing system. Completing Care and Maintenance: It is your responsibility to promptly correct all deficiencies observed during Care and Maintenance inspections. SOPREMA encourages you to retain the services of a professional contractor or consultant if you do not have personnel qualified to conduct routine Care and Maintenance. All roofing and waterproofing system repairs and modifications must be performed by an authorized contractor retained by you. Temporary emergency repairs may be made to the roofing or waterproofing system as allowed under the terms and conditions of the warranty. In the event of significant damage, it is prudent for you to retain the services of a roofing or waterproofing processional, and notify your insurance carrier where applicable. Cleaning the Roofing or Waterproofing System: The roofing or waterproofing system must be maintained free of debris that may result in damage. When necessary, low-pressure tap water dispensed from a garden hose and/or brooms may be used to remove dirt and debris from the surface of the roofing or waterproofing system. Where permissible, mild detergents may be used to clean surfaces, then use clean water to remove the detergent. Prevent dirt, debris and other inappropriate materials from entering storm drainage systems. Tools that may damage the roofing or waterproofing system, such as metal shovels and rakes, should NOT be used. High-pressure water should NOT be used unless specifically authorized by SOPREMA.. Documenting Warranty Claims: Refer to Form 900 — Warranty Claim Procedure, included with your SOPREMA warranty. All valid daims must include a copy of your Care and Maintenance log. Additional Resource: For further information and guidance, you may wish to review the Manual of Roof Maintenance and Repair jointly published by the National Roofing Contractors Association and the Asphalt Roofing Manufactures Association, or other applicable industry publications. This SOPREMA Care and Maintenance Guide includes the minimum requirements of your SOPREMA Warranty. Additional care and maintenance beyond these minimum requirements is encouraged. (Form 901) (07/2013) Care and Maintenance Log: (Sample) Instructions: The following activities are required to be completed and documented two (2) times per year as a record of care and maintenance: Date of Inspection: Inspected by (Name): Conditions: Record observations of accessible roofing and waterproofing system as well as conditions at all edges, terminations and penetrations. Record observations of any other conditions that may have an effect on the roofing or waterproofing system. Leaks: Document all roofing or waterproofing system leaks. Refer to Form 900 — Warranty Claim Procedure. Repairs and Modifications: Date of all work, and the individual or company who completed work that may have an effect on the roofing or waterproofing system. Other Information observed or noted that may have an effect on the roofing or waterproofing system: Inspected by (Signature): (Form 901) (07/2013) Warranty No.: 101-011568 WARRANTY CLAIM PROCEDURE Warranty claims must be submitted within 30 days after a leak or other related issue is discovered. Time is of the essence. Claims must be submitted to SOPREMA's Warranty Department, at the address provided below. SOPREMA will initiate the claim process when all of the following items have been received: 1. Completed Warranty Claim Form. Refer to the Warranty Claim Form printed on the reverse. 2. Photos or other documentation of the conditions you believe give rise to the claim. 3. A copy of your Care and Maintenance log. 4. Your Warranty Number as indicated on this form. Upon receipt of a properly documented warranty claim, SOPREMA will determine if a site visit is necessary. If so, you will be contacted in order to coordinate with SOPREMA. You are required to provide SOPREMA and its designees with prompt, free, safe and ready access to roofing or waterproofing surfaces that are free of snow, ice, and any other obstructions. You must provide access to the building and roof during normal business hours or after hours if requested. When SOPREMA determines the claim is valid, SOPREMA will remedy the leak in an expeditious manner. Conditions may vary, thus the remedy and timetable may vary as well. The decisions of SOPREMA with respect to the validity of claims and the scope, manner, and timetable of repairs are final and binding. In making warranty repairs, SOPREMA will closely match materials and colors, as inventories allow. Authorized warranty repairs shall become subject to the warranty, but do not extend its term. Should an investigation reveal that a claim is not covered by this warranty, you will be promptly notified of non - coverage and may be invoiced for the investigation expenses incurred by SOPREMA. Payment shall be due 30 days after invoice date. Failure to pay within terms could result in warranty cancellation. It is your responsibility to remedy any condition not covered by the warranty that has an adverse effect on the roofing or waterproofing system. If you remedy the condition within a reasonable time, then the warranty will remain in effect for the unexpired portion of its term. Failure to address repairs or related issues in a timely and reasonable fashion could result in conditions not covered by the warranty. It is your responsibility to remedy conditions not covered by the warranty that may have an effect on the building or occupancy induding other damages, safety, codes, laws and regulations. For additional information contact: SOPREMA, Inc. Warranty Department 310 Quadrat Drive Wadsworth, Ohio 44281-9571 Phone: (800) 356-3521 Fax: (330) 334-7903 Email: warrantvclaimsesoorema.us (Form 900) (07/2013) SOPREMA. WARRANTY CLAIM FORM DATE: WARRANTY NO.: OWNER NAME: Phone: Fax: Email: BUILDING CONTACT: Phone: Fax: Email: BUILDING NAME: BUILDING ADDRESS: CITY: STATE: ZIP: DID YOU REVIEW THE WARRANTY BEFORE SUBMITTING THIS CLAIM? YES NO IS THERE A ROOFING OR WATERPROOFING SYSTEM LEAK ASSOCIATED WITH THE CLAIM? YES NO IF YES, DATE LEAK WAS FIRST DISCOVERED: LOCATION AND DESCRIPTION OF PROBLEM: OWNER'S AUTHORIZED SIGNATURE: Date: Please submit your claim to: SOPREMA, Inc., 310 Quadral Drive, Wadsworth, OH 44281-9571, Attention: Warranty Department. Claims may also be faxed to (330) 334-7903 or emailed to warrantvciaimstitssoprema.us. For questions, call the Warranty Department at (330) 334-0066, or toil free at (800) 356-3521. Thank you, SOPREMA, Inc. Warranty Department (Form 900) (07/2013) WARRANTY TRANSFER PROCEDURE This document describes the procedure that must be followed to obtain a transfer of warranty. Whether or not a particular roof qualifies for warranty transfer depends on the condition of the roof. Not all roofs will qualify for a transfer. 1 The new owner must complete, sign and send a Request for Warranty Transfer form to Soprema. Mailing instructions are printed on the form, which is available for viewing and printing at <www.soprema.us>. If you do not have access to the Internet, call the National Warranty Department at (800) 356-3521, and a form will be mailed to you. 2. Soprema must be paid a nonrefundable warranty transfer fee of $500 plus the nonrefundable portion of an inspection fee of $1,000. The check should be made payable to "Soprema, Inc." and sent with the request for transfer. After receiving both the request for transfer and funds in the amount of the nonrefundable fees, Soprema will dispatch an inspector to the building for the purpose of walking the roof. The inspector must be granted access to the roof during weekday, daylight hours. We will attempt to give no Tess than one day's prior notice of when the inspector will be arriving. To the extent the inspector's fees (which will be charged at a rate of no more than $50 per hour) plus costs exceed $1,000, you will be invoiced for the difference. The transfer of the warranty, even if approved by Soprema, will not become effective until the inspector's fees and costs are paid in full. 3. Promptly after inspection, you will be noted as to whether or not the condition of the roof is such that it qualifies for a warranty transfer. Reasons a roof might not qualify for warranty transfer include extensive damage due to physical abuse, unauthorized post -installation work on or about the roof, and failure to properly maintain. Warranty transfer might be made contingent upon completion of repairs described by the inspector. If repairs are required, they must be completed by a Soprema Authorized Applicator in strict compliance with Soprema's current specifications and approved installation practices within 30 days of the date you receive the scope of work, unless Soprema agrees in writing to a longer time period. You agree to bear the expense of making the repairs. Soprema will require written certification from the applicator that all the repairs have been completed in accordance with the requirements of this paragraph. Soprema also reserves the right to inspect the repairs before warranty transfer. 4. Upon completion of all of the above to the satisfaction of Soprema, a transfer rider will be issued. (Revised 6/2(308) SOPRENIA® REQUEST FOR WARRANTY TR ANSFER DATE: ORIGINAL OWNER NAME: NEW OWNER NAME: Phone: Fax: BUILDING NAME: BUILDING ADDRESS: CITY: STATE: ZIP: WARRANTY NUMBER: WARRANTY YEARS: COMPLETION DATE: You, the "New Owner" listed above, hereby requests that the stated warranty be transferred to you effective as of date you acquire title to the building. By signing below, you accept all of the terms and conditions of the specified warranty. By signing below, you acknowledge that this form is a request for transfer only. The warranty has not been transferred. If Soprema accepts this request, Soprema will issue a Notice of Transfer Rider to you. Until such a rider is issued, you do not have any rights under the warranty nor will Soprema accept any warranty claims by you. The first step to obtaining Soprema's consent to the proposed warranty transfer is to pay Soprema the sum of $1,500 as a non-refundable fee. Promptly after receiving your funds, Soprema will arrange to have the roof inspected. The inspector will develop a detailed description of the scope of any work necessary to bring the roof to a warrantable condition. If work is required, a copy of the scope of work will be sent to you at the address provided below so you may contact an authorized Soprema roofer for a quotation of the costs involved in making the repairs. The repairs must be made by a Soprema authorized roofer within 30 days of the date you receive the scope of work, unless Soprema agrees in writing to a longer time period. If the repairs are made within the applicable time period to the satisfaction of Soprema, Soprema will promptly issue a Notice of Transfer Rider to you. NEW OWNER SIGNATURE: Date: NEW OWNER'S ADDRESS: Please retum this form to: Soprema, Inc., National Warranty Department, 310 Quadral Drive, Wadsworth, OH 44281- 9571. Fax: (330) 334-7903 Include with this form a copy of the warranty document to be transferred and your $1,500 check made payable to "Soprema, Inc." New Owner. By: Name: Title: 310 Ouadral Drive, Wadsworth, OH 44281 SOPREMA INC. Phone (330) 334-0066 1 (800) 356-3521 Fax (330) 334-4289 (Revised 6/2008) Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofino.com N it Ili ail SUBMITTALS 07221- Roof Insulation 07513-Mod. Bitumen Roofing PROJECT Interurban Pump Station 13980 Interurban Ave S Tukwila, WA PREPARED FOR FILEcosyQ� 2. 2014 Penult No. bu4. Plan review approval is subject to arms and omissions. Approval of construction documents does not at horin the violation of any adopted code or ordnance. Receipt of approved Field Copy adonowIe ect Date: "7 - 9 ^ r ti City of Tukwila BUILDING DIVISION Centennial Contractors Enterprises, Inc. 5113 Pacific Hwy East, Suite 1 Fife, WA SEPARATE PERMIT REQUIRED FOR: LtrMechanicai IioElectrkcad f '1umbing GP6as Piping C!? j of Tukwila ".f DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 07 2014 Cityof Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVED CITY OF TUKWILA JUN202014 PERMIT CENTER WRI PROJECT 14-033 SUMNER (253) 863-4455 SEATRE (206) 575-0078 FAX (253) 863-8311 t»1-OI°t5 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofina.com N 5!\I 1t(11,IfII\.. i\I Interurban Rump Station ROOF DRAWING • Roof Plan • Roof System Description 1 PRODUCT DATA 2 • Roof System Product Data CERTIFICATION 3 • Approved Applicator Letter WARRANTIES • Manufacturer's Sample Warranty • Contractor's Sample Warranty 4 June 2nd, 2014 WRI PROJECT 14-033 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.waynesroofing.com DRAWINGS 1 North 53'11" • 0 O • i 0 • i • • LO Waynes Roofing. Inc. 13105 Houston Road Sumner, WA 98390 Sum (253) 8634435 Sea Fax (353) 6635311 INTERURBAN PUMP STATION ROOF P_AN Date 5/00/14 Drawn By Gabriella Aguirre Rev. Job No. Scole N.T.S. Section Sheet 001 Insulation Data Bottom Middle Top i Notes: Adhered tapered insulation system set in Type IV hot asphalt. MANUFACTURER Hunter Panel Hunter Panel Blue Ridge TYPE Flat Insulation Tapered Insulation Wood Fiber THICKNESS 2' Varies R - VALUE R-11.4 Avg. R-14 Mln. R-1.39 NO. OF LAYERS Multiple INSULATION FASTENING PATTERN Wall and Curb base Flashings to consist of Fluid applied Alsan Flashing with Fleece reinforcement. An RFI will be generated to clarify the wall base flashing assembly components to be incorporated into the project. ATTACHMENT Adhered Adhered Adhered FASTENER TYPE Hat Asphalt Hot Asphalt Hot Asphalt FASTENER LENGTH N/A N/A N/A BOARD SIZE 4'x4' 4'x4' 4k4' FIELD FASTG N/A N/A N/A PERIMETER FASTG N/A N/A N/A CORNER FASTG N/A N/A N/A BASE FLASHING COMPONENTS FM REQ. (Pattern Only) N/A N/A N/A SEBS Modified Asphalt SEBS Modified Asphalt SEBS Modified Asphalt Elastophene FR GR Cap Sheet (adhered) Elastophene 180 Sanded (adhered) Modified Sopra-G Base (adhered) Type IV Asphalt y e f T ' t S. ftTi k t Jyi t i t i a. a. a. A. a. a. a. a. a. A s Type IV Asphalt Type IV Asphalt SEBS Modified Asphalt Asphalt Primer ISOM '/2" HD Wood Fiber Coated 6 Sides (adhered) %" Tapered Insulation (adhered) 2" Base Layer of Insulation (adhered) Sopralene 180 Sanded (adhered) Concrete Deck (Existing) Interurban Dump Station System Description Section Date 05/23/14 Drawn By M. Trout Rev. Job No. 14-033 Scale N.T.S. Sheet 002 X.3 J O P • b Q�b ii I Z x• 3 I 1 I 1 1 1 x 1 1 1 I 1_1 1 1z b Q b Q • 'p Q b Q Y IZA.- , I ll•3 , Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.waynesroofing.com PRODUCT DATA 2 PRODUCT DATA SHEET PDS-274 SOPREMA® ELASTOPHENE FR GR ELASTOPHENE FR GR (42) (FR High Slope) Order No. 01181* *Cap sheet order numbers are for WHITE CAP SHEETS ONLY. Contact Customer Service or your Sales Representative for other available cap sheet colors and special order requirements. Rev 04/13 001001cimH21 CR J (<X)1. R(XW RATING. COUNCTI. MEMBER DESCRIPTION & APPLICATION Elastophene FR GR is composed of selected SBS modified bitumen applied onto a glass mat reinforcement with high brush sanded bottom and granule top surface. Elastophene FR GR field cap membrane ply is adhered to a properly prepared, clean, dry and/or primed (where required) substrate by using hot asphalt or cold adhesive. See published Specifications and Approved Details. COMPOSITION & PACKAGING Product/ Property ELASTOPHENE FR GR Reinforcement fiberglass reinforcement Elastomeric Bitumen selected blend of bitumen and SBS thermoplastic polymers Topside granules Underside lightly sanded Approximate Nominal Thickness 136 mils (3.4 mm) Approximate Roll Coverage 97.5 ft2 (9.1 m2) Side Lap 3" (76 mm) End Lap 6" (152 mm) Roll Length 33 ft (10 m) Roll Width 39" (1 m) Approximate Roll Weight 94 Ibs (42.6 kg) Rolls per Pallet* 30 * Rolls stocked upright on pallets APPROVALS See Underwriters Laboratories Inc. File #R11436, FM Approvals, ICC/ES, Miami -Dade County or Florida Building Code Product Approval Listings for current Approved Roof Assembly combinations. Soprema is ISO-9001:2008 Certified. WARRANTY Contact your local SOPREMA representative for project warranty offerings. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289' Gated paid irionnlion is pvidad an this Rad& Ma Sheet The physical pmped reported Ise anbaaedm tingcadged Mkcontrolled I/Eralory onitionsa000rdngbacovtedtest sta**. ELASTOPHENE FR GR PDS-274 IIISOPREMA© PAGE 2 Rev 04/13 PHYSICAL PROPERTIES Physical Property per ASTM D 6163, Type I, Grade G MD XD Peak Load at 0 ± 3.6°F kn/m (lbf/in) 20 (116) 18 (104) Elongation at 0 ± 3.6°F % 5.0 6.2 Peak Load at 73.4 ± 3.6°F lbf/in 10 (57) 10 (57) Elongation at 73.4 ± 3.6°F % 4.0 4.0 Tear Strength at 73.4 ± 3.6°F lbf 82 78 Low Temperature Flex °F -15 -15 Dimensional Stability % <0.1 <0.1 Compound Stability Temp °C (°F) 121 (250) 121 (250) Granule Embedment g/max 0.8 0.8 Ultimate Elongation % 60 51.4 * Minimum values before and after Heat Conditioning *Test results for manufacturing plant in Wadsworth, OH GENERAL SOPREMA is a Certified ISO 9001:2008 worldwide producer of bituminous membranes with factories in Europe and North America. Waterproofing sheets have been produced by SOPREMA since 1908. Today, through a special mixture of components, SOPREMA membranes redefine the qualities indispensable to a high performance roof membrane: elasticity, flexibility, heat & fatigue resistance. SOPREMA SBS modified bitumen membrane assemblies typically consist of base and top ply membranes that have specific type reinforcements in order to meet specific ASTM Standards. The two ply system provides a resistance to punctures and tears, as well as ensuring an effective distribution of stress points. The two ply system operates in a homogeneous fashion. The bitumen in each layer moves uniformly to offer continuous protection. ,� gooSolar CR C COOL ROOF RATING COUNCIL Initial Weathered Reflectance 0.27 0.25 Thermal Emittance 0.88 0.90 Rated Product ID Number 0772-0020 Licensed Seller ID Number 0772 Classification Production Line Cool Roof Rating Council ratings are determined for a fixed set of conditions, and may not be appropriate for determining seasonal energy performance. The actual effect of solar reflectance and thermal emittance on building performance may vary. Manufacturer of product stipulates that these ratings were determined in accordance with the applicabl Cool Roof Rating Council procedures. CA Title 24 Compliant Reflectivity Emmissivity Initial/ Weathered - 0.27 / 0.25 0.88 / 0.90 CRRC Rated Recycled Content 0% Production Location: LEED Wadsworth, OH, Gulfport, MS & Chilliwack, BC Solar Reflective Index(SRI) Initial Weathered 27 25.3 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 General product information is provided on this Product Data Sheet The physical property values reported here are based on testing conducted under controled laboratory conditions according to accepted test standards. E1-04) PRODUCT DATA SHEET PDS-350 71SOPRENIA® Rev 05/11 ELASTOPHENE 180 SANDED ELASTOPHENE 180 SANDED (20) Order No. 00210 DESCRIPTION & APPLICATION Elastophene 180 Sanded is composed of selected SBS modified bitumen applied onto a non -woven polyester reinforcement with a sanded underside and high brush sanded top surface. The field and flashing base membrane ply is adhered to a properly prepared substrate by using hot asphalt or cold adhesive. Optional inner ply(s) or the field cap membrane ply is bonded to the properly prepared, clean, dry and/or primed (where required) Elastophene 180 Sanded top surface with hot asphalt, cold adhesive or heat welding application methods. A self-adhesive cap sheet can also be adhered to the sanded top surface when the Elastophene 180 Sanded membrane is properly prepared with Soprema SA Primer and Soprema Sealant is applied to all side and end lap edges not having a bitumen bleed -out prior to application. ELASTOPHENE 180 SANDED is also used as a protection sheet in an approved Colphene H waterproofing assembly. The ELASTOPHENE 180 SANDED membrane is installed with minimum two (2") inch (51 mm) sidelaps and four (4") inch (102 mm) end laps, or in accordance with specific project requirements. See published Specifications and Approved Details. COMPOSITION & PACKAGING Product/ Property ELASTOPHENE 180 SANDED Reinforcement polyester Elastomeric Bitumen selected blend of bitumen and SBS thermoplastic polymers Topside lightly sanded Underside lightly sanded Approximate Nominal Thickness 90 mils (2.2 mm) Approximate Roll Coverage 147 ft' (13.6 m2) Side Lap 3" (76 mm) End Lap 6" (152 mm) Roll Length 49 ft (15 m) Roll Width 39" (1 m) Approximate Roll Weight 92 Ibs (41.7 kg) Rolls per Pallet* 30 * Rolls stocked upright on pallets 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 Gerard praluct infornelian is Reirthd on this Prod& Ma Sheet. The plessici property ellues muted here se based an testing caxided eider controlled laborlay =dikes accertirg b melted ted sbeekeds ELASTOPHENE 180 SANDED PDS-350 SOPREMA® PAGE 2 Rev 05/11 PHYSICAL PROPERTIES Physical Property per ASTM D 6164, Type I, Grade S MD XD Tensile - Max Load at 0 ± 3.6°F lbf/in 117 83 Elongation at 0 ± 3.6°F % 29 22 Tensile - Max Load at 73.4 ± 3.6°F lbf/in 70 70 Elongation at 73.4 ± 3.6°F % 56 61 Tear Strength at 73.4 ± 3.6°F lbf 120 87 Low Temperature Flex °F max -15 -15 Dimensional Stability % max <0.5 <0.5 Compound Stability Temp F 215 215 Granule Embedment g/max NA NA Minimum values before and after Heat Conditioning Test results for manufacturing plant in Wadsworth, OH APPROVALS See Underwriters Laboratories Inc. File #R11436, FM Approvals, ICC/ES, Miami -Dade County or Florida Building Code Product Approval Listings for current Approved Roof Assembly combinations. Soprema is ISO-9001:2000 Certified. GENERAL SOPREMA is a Certified ISO 9001:2000 worldwide producer of bituminous membranes with factories in Europe and North America. Waterproofing sheets have been produced by SOPREMA since 1908. Today, through a special mixture of components, SOPREMA membranes redefine the qualities indispensable to a high performance roof membrane: elasticity, flexibility, heat & fatigue resistance. SOPREMA SBS modified bitumen membrane assemblies typically consist of base and top ply membranes that have specific type reinforcements in order to meet specific ASTM Standards. The two ply system provides a resistance to punctures and tears, as well as ensuring an effective distribution of stress points. The two ply system operates in a homogeneous fashion. The bitumen in each layer moves uniformly to offer continuous protection. WARRANTY Contact your local SOPREMA representative for project warranty offerings. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 General product information is provided on this Product Data Sheet. The physical property values reported here are based on testing conducted under controlled laboratory conditions according to accepted test standards. PRODUCT DATA SHEET PDS-101 SOPREMA® MODIFIED SOPRA-G MODIFIED SOPRA-G (03) *Contact Customer Service for additional order numbers. Rev 05/11 Order No. 00107* DESCRIPTION Modified Sopra G (modifigd with SBS) is a ASTM 4601, Type II and G2 fiberglass base sheets. The Modified Sopra G base sheet is used as an anchor sheet for hot mopped, cold adhesive or heat welded roof assemblies. This base sheet is suitable for use to form BUR roof assemblies or is used in combination with SBS membranes when they are completely adhered either by hot mopping or cold adhesive. The Modified Sopra-G sheet may be used as an anchor sheet for waterproofing assemblies or as a seperation sheet over approved Colphene H waterproofing systems. See published Specifications and Approved Details. COMPOSITION, PACKAGING & PROPERTIES Product/Property Modified Sopra-G Reinforcement Fiberglass Bitumen SBS Modified Topside Sanded Underside Sanded Approx. Nominal Thickness 1.2 mm (48 mils) Approximate Roll Coverage 28 mz (300 ft2) Side Lap 76 mm (3") End Lap 152 mm (6") Roll Length 33 m (108') Roll Width 0.9 m (3') Approximate Roll Weight 41.7 kg (92 lbs.) Rolls per Pallet* 20 `Rolls stocked upright on pallet Product/ Properties per ASTM D 4601-04 Modified Sopra-G Net Dry Mass (Ib. 100 ft2) 28.4 Moisture (% max @ time of mfg.) <1 Mass of desaturated glass mat (Ib. 100 ft2) 1.70 Asphalt (min. lb./100 ft2) 10 Parting agent & stabilizer (max. Ib./100 ft2) NA Load strain properties © 77° F (25° C) Breaking Strength 60 MD 44 XD Pliability (%/z in. radius failures) No Cracking Minimum values before and after Heat Conditioning. Test results for manufacturing plant in Wadsworth, OH7/24/03 WARRANTY Contact your local SOPREMA representative for project warranty offerings. APPROVALS See Underwriters Laboratories Inc. File #R11436, FM Approvals, ICC/ES, Miami -Dade County or Florida Building Code Product Approval Listings for current Approved Roof Assembly combinations. Soprema is ISO-9001:2000. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 Gaya( product Sionstion is pronin on this ProdudData Sheet. The physical property values repaited here are toed mtesti%conned udercorbdled la6adaycoM6as scoring tomantel test stadads. DATA SHEET STRUCTODEK® CEWTEX® NO.002 Insulation Board DESCRIPTION CELOTEX STRUCTODEK is not only an integral roofing system component; it also makes roofing easier with physical properties that generate structural rigidity and dimensional stability. The fiberboard composition of STRUCTODEK possesses natural bonding qualities, resulting in superior adhesion capabilities. Adhesive tightly grasps the fibers of STRUCTODEK without causing excess absorption, providing a solid and secure roof system which bonds very well with many asphalt, coal tar, and cold -process adhesive products. The lightweight nature of STRUCTODEK is better than heavier alternatives and will keep the roof load below the specified maximum weight. STRUCTODEK is offered in coated one side (CIS), integral coated six -sides (C6S), and uncoated (natural). USES STRUCTODEK can be used as an insulation board, cover board, or re-roof/recover board. STRUCTODEK is a high -density roofing board and is designed for low -slope applications and systems. SPECIFICATIONS • ASTM C 208, Type II • ASTM C 209 • UL Classified to Canadian Std CAN/ULC-S107 and US Std UL 790 • FM Approved Class 1 — FMRC Standard 4450/4470 • CAN/ULC-S706-09 Type II, Classes 1 and 2 • Canadian Evaluation CCMC #13186-L • NOA 10-0120.04; Miami -Dade County, FL; Expiration date 09/18/13 MASTERFORMAT NUMBER AND TITLE 07 22 16 - Roof Board Insulation JULY 2012 (Supersedes July 2010) FEATURESBENEFITS • Approved in UL Class A rated roof systems. • Structurally rigid and dimensionally stable board easily handles heavy foot traffic and wheeled loads. ■ Superior adhesion without excess absorption. ■ Contributes to thermal insulation with R-values ranging from 1.3 to 5.0. • Lightweight and easy to install, without the irritating fiberglass dust of glass mat faced gypsum board. • Easily handles hot asphalt, non -blistering. ■ Cuts with a standard utility knife. • Compressive strength exceeds the Canadian standard at 10% deformation for thickness. PRECAUTIONS Do not expose to open flame or excessive heat. May smoulder if ignited. If ignited, extinguish completely. Do not apply flame directly to material when installing a modified bitumen system. Material must be kept dry at all times; in storage and during application. Apply only as much STRUCTODEK in one day as can be covered by completed roofing system that day. Do not use as an underlayment for shingles. In re -roofing applications, all wet areas in old roof should be cut out and replaced. Before material is installed, remove all loose and protruding gravel. STRUCTODEK must not be used in close proximity to chimneys, heater units, fireplaces, steam pipes, or other surfaces which could provide long-term exposure to excessive heat (maximum 212° F) without adequate thermal protection. Consult appropriate heating appliance manufacturer's instructions before installation. LEED INFORMATION May help contribute to LEED credits: • MR Credit 2: Construction Waste Management • MR Credit 4: Recycled Content • MR Credit 5: Regional Materials • MR Credit 6: Rapidly Renewable Materials • IEQ Credit 4.4: Low -Emitting Materials — Composite Wood and Agrifiber Products Thickness (nominal) 1/2" 25 / 32" 1" 1-1/2" 2" Board Sizes 4'x4';4'x8' 4'x4;4'x8' 2' x 4'; 4' x 4'; 4' x 8' 2'x4';4'x4' 2'x4';4'x4' Boards/Unit 4'x4';4'x8'=90 4'x4;4'x8' =60 2'x4'=90 4'x4';4'x8'=45 2'x4'=60 4'x4'=30 2'x4';4'x4'=46 Squares/Unit 4' x 4' = 15.20; 4'x8'=30.10 4' x 4' = 9.60; 4'x8'= 19.20 2' x 4' = 6.72; 4'x4'=7.36; 4'x8'=14.72 2' x 4' = 4.48; 4'x4'=4.80 2' x 4' = 3.36; 4'x4'=6.72 Deflection at specified min. load, max inches 50.76" (519mm) No ASTM Data 50.42" (511 mm) No ASTM Data 50.21" (55mm) Flute Span 1 5/8" (40mm) 2-5/8" (67mm) 2-5/8" (67mm) 4-3/8" (111mm) 4-3/8" (111mm) Compressive Strength 15% Def. ASTM C165 48 psi BLUE RIDGE FIBERBOARD 250 Celotex Dr. Danville, VA 24541 1-866-850-8834 www.blueridgefiberboard.com • info@blueridgefiberboard.com HUNTER PANELS ENERGY S ART POLYESO PROFILES _ ,... aI._t— .d morff-EillnilliglIMINZIEM Codes and Compliances • ASTM C 1289. Type 11, Class 1 Grade 2 (20 psi) or Grade 3 (25 psi) • International Building Code (IBC) Chapter 26 • State of Florida Product Approval Number FL 5968 • Miami Dade County, FL NOA NO: 09-0915.15 — Exp. 1.14.2015 Underwriters Laboratories Inc Classifications • UL 1256 • Insulated Metal Deck Construction Assemblies - No. 120, rains no CFCs, 123, 292 irtually no GWP UL 790 • UL 263 Hourly Rated P Series Roof Assemblies UL Classified for use in Canada • Refer to UL Directory of Products Certified for Canada for more details • CCMC 13460-L • UL Certified for Canada, CAN/ULC-S126, CAN/ULC-S101, CAN/ULC- S107 UR, Modified hs per ►tn), '/a" ' (1220mm x nimum to 4.5° special request UL Class A ratings • Singled' t aliasted, Mechanically Attached, fully Adhered odified Bitumen Systems TAPERED H-SHIELD Sloped Polyisocyanurate Insulation Tapered H-Shield PRODUCT DESCRIPTION Tapered H-Shield is a sloped rigid roof insulation panel. composed of a dosed cell polyisocyanurate foam core manufactured on lin reinforced facer on , both sides. °Tapered d to promote positive drainage and } ponding wa . r best results, request Hunter Panels Tapeesign Team. assistance FEATURES AND BE TS s� ts 'tared with NexGen Chemistry:" , is Zero ODP,°EPA Compliant, and pplication to steel deck f covering systen NEL CHIACTERISTIIC able :` two grades: compressive • Ava'" 244 .' (114m m r foot in 4'x4' (1220mm Omm) and anels in thicknes. f .5ft (13 cers are availabl+ APPLICATIO ions requiring FM C • Built -Up Roofing: Asphalt and Coal Tar Factory Mutual Approvals • FM 4450, FM 4470 • Approved for Class 1 insulated steel deck constructions for 1-60 to 1-270. Refer to fM Approval's RoofNav for details on specific systems. LEED Potential Credits for Polyiso Use (PRE LEED V4) For current LEED V4contribution information go to www.PIN1A.org or www.hpanels.com Energy and Atmosphere • Optimize Energy: Performance • Measurement & Verification Materials to Resources • Material Reuse • Construction Waste Management • Recycled Content , • Local and Regional :Materials Innovation and Design W W W. H U N T E R P A N E L S. C O M 8 8 8. 7 4 6. I I I 4 HUNTER PANELS ENERGY SMART POLYISO TYPICAL PHYSICAL PROPERTY DATA CHART PER ASTM C 1289 POLYISO FOAM CORE ONLY PROPERTY TEST METHOD Compressive ASTM D 1621 Strength VALUE 20 psi* (138kPa, Grade 2) Dimensional Stability ASTM D 2126 2% linear change (7 days) Moisture Vapor ASTM E 96 Transmission < 1 perm (57.5ng/(Pa.s.m2)) Water Absorption ASTM C 209 < 1% volume Service Temperature Single -Ply $ Ballasted Singl ` System: Each Tapered ` ield pane es and s ' joints° veringacco ._µ. totlie ' chanicnl is of adjac Adhered Sit TaperedH-: 1220mm x II mopping o hovering according toy'' ched -100° to 250° F (-73°C to 122°C) *Also available in 25 psi, Grade 3 facer ufactur Ply System I on the roof deck els. Install the rot pecifications: WARNINGS AND LIMITATIONS Insulation must be protected from open flame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof covering material. Hunter Panels will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. For more information refer to the Storage and Handling Technical Bulletin at www.hpanelsacom, or refer to PIMA Technical Bulletin No. 109: Storage & Handling Recommendations forPolyiso Roof Insulation at www.polyiso.org. I the roof cov according e manufacturer's specifications. dtother d H Shield ulation adhe ufacturer's spI, Built Up, andModified �i rt Srjstems eck with fasteners and plates (appropr try.deck type). Maximum. be adhered to ,a prepared concrete de4 r° subsequent layers ;of insulation' or cold applied mastic. Butt edges and joints of adjacent panels. Install ans. Each Tapered H-Sh►ed to the roof deck with fasteners and plates (appropriate to the deck type). Maximum 4'x4' (1220mm x 1220mm) panels of Tapered H-Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt, insulation adhesive or cold applied mastic, Butt edges and stagger joints of adjacent panels. -Install the roof covering according to the manufacturer's specifications. HUN± E R Energy Smart Polyiso HUNTERPANELS.COM 15 FRANKLIN STREET, PORTLAND, ME 04101 • 888.746.1114 • FAX: 877.775.1'769 PIMA POLYISOCVANURATE INSULATION MANUFACTURERS ASSOCIATION N1=,?GLN PRINTED WITH SOY INK MIX N SC meralA.• I.um.. FSC C102465 NEW YORK • ILLINOIS • FLORIDA TEXAS UTAH PENNSYLVANIA WASIIINGTON 0YA TAKE THE HUNTER ADVANTAGE The Hunter Panels Tapered Design Department Advantage t. The Hunter P work with you from start to finish to engineer the appropriate tapered design system for youi roof configuration and drainage requirenients; 1- 1 1 THEI SERVICES' _ , • ' Fast and accurate quotatiOnsproduteizt via Dodge, fax, arl e-mail ', • ', Featuring Tapered'? lui-8( AutoCAD deSigb software • .pe,sign,Assistance7--conceptual layouts forVecifiers and or owners looking for professi9naldes0 expertise , • field, assistance -arid fob -start -as requested , -, , • SpecificationdeVeloprnent and code compliance consultations , ', • -Sign-offs oh drawings , ! ‘ r , THE PtioDUGTS \— More design optiont to fit your needs , , , Tapered I -I -Shield', , 1. ,, ' ', ', ' ' ' „.. , , 1 TaPered H-Shield CG"- premiiini perforrnance coated fiberglass facer, for cold -plied and spray applied applicatiOns ' • ', Tapered ft:Shield VVF ,- Wood fiberboard, designed specifically for BUR, .Modified_ . S ,i _ 1 BitUnieh systems 1 $ 4' X 4' and 4' x'8' , per_ foo_t_):-1/2"; t/44',.6",%",, 1/2" \apered Extended ParierSystem Advantage , Unique extended panefs-aVailable from Hunter Panels: 4.0" - 4.5" ' - Q 2.5.. _ 4.5.., Z 3.5" - 4.5"' Standard versus xtended'CdmpavrisOn Video available at www.I-1 nterPanels.Com • Prel-Cut Hips &Valleys • Hinged Target® Surnp - Hinged 8' x 8' Sump, pre -assembled in o SALES BENEFITS 4 - HVN+ER '• Single Source Responsibility • - - Tapered Design by manulacturer Energy Sm,11-i POIVIS, • 'More Design optionslo fit your budget - and bUilding requirements ' 888 746-1114 • ContaCt uS for Architectural and or 15 r . RANKLIN STREET, PORTLAN OWner Presentations MANUFAC • Over 40 years of tapered deSign';exPertise • .0n+line Tapered Quote Request Form - bsIiy to upload submittals and drawings via our website www.hunterpanefs.com 1 ',... 1 , i • I , - 1 • , • I . / ;piece 1 '1 , ME 04101 FAX: 877-775-1769 RING FACILITIES: NEW YORK UTAH ILLINOIS PENNSYLVANIA FLORIDA WASHINGTON TEXAS WW.HUNT4RPANELS.COM , t 0 rj- 0 TAKE THE HUNTER ADVANTAGE TAPERED PANELS LOADING DIAGRAM NOTE: Green text indicates tapered panels utilized in Hunter Panels Extended Panels Tapered Systems 3 0" 4 O" 5 0" 0 5" 1 5" 2 5" 3 5" 4 5" 1 5.5" 1 6.5" 1 7.5" 1 6 5" AA A B C 0 E F FF CLL BELOWEI F1 FF1 ,.-REFERENCE .ctdiniss1ll E F FF - ‘•oelle111©111 FF 4.0' 'SO FSC MIX lwpasBN Fst 1 ounces FSC C102465 1 5" 0 5" 2 5" 3 5" REFEPENCE FILL BELOW --- y 2 ZZ .. 31.OPE 4.0. ISO Y 2 ZZ 0 TAPERED PANELS - 48" x 48" BOARD DIMENSIONS BD FEET PCS PER SQ FT PER WEIGHT STYLE IN INCHES PER PANEL BUNDLE BUNDLE PER SQ FT AA 0.5" - 1.0" 12 64 1024 0.227 A 1.0" - 1.5" 20 38 608 0.308 B 1.5" - 2.0" 28 26 416 0.389 1/8 C 2.0" - 2.5" 36 20 320 0.471 D 2.5" - 3.0" 44 16 256 0.552 E 3.0" - 3.5" 52 14 224 0.633 F 3.5" - 4.0" 60 12 192 0.714 FF 4.0" - 4.5" 68 10 160 0.747 X 0.5" - 1.5" 16 48 768 0.259 Y 1.5" - 2.5" 32 24 384 0.422 Z 2.5" - 3.5" 48 16 256 0.584 1 /4 ZZ 3.5" - 4.5" 64 12 192 0.747 G 1.0"-2.0" 24 32 512 0.341 1 /2 H 2.0" - 3.0" 40 18 288 0.503 1 3.0" - 4.0" 56 12 192 0.666 Q 0.5"-2.5" 24 32 512 0.341 5" 5 QQ 2.5" - 4.5" 56 12 192 0.666 XX 1.0" - 3.0" 32 24 384 0.422 JJ 0.5" - 1.25" 14 54 864 0.243 KK 1.25" - 2.0" 26 28 448 0.357 LL 2.0" - 2.75" 38 20 320 0.487 MM 2.75" - 3.5" 50 14 224 0.601 3/16 J 1.0" - 1.75" 22 34 544 0.324 K 1.75" - 2.5" 34 22 352 0.438 L 2.5" - 3.25" 46 16 256 0.568 M 3.25" - 4.0" 58 12 192 0.682 3/8 SS 0.5" 2.0" 20 38 608 0.308 TT 2.0" - 3.5" 44 16 256 0.552 S 1.0" - 2.5" 28 26 416 0.389 T 2.5" - 4.0" 52 14 224 0.625 1 0.5" - 0.75" 10 76 1216 0.195 2 0.75" - 1.0" 14 54 864 0.243 3 1.0" - 1.25" 18 42 672 0.276 4 1.25" - 1.5" 22 34 544 0.324 1/16 5 1.5"-1.75" 26 28 448 0.357 6 1.75" - 2.0" 30 7 2.0" 24 384 0.405 2.25" 34 22 352 0.438 8 2.25" 2.5" 38 20 320 0.487 "IQ afea wllno m� SOY INK ,H U N T E R PANELS ENERGY S ART POLYISO H-SHIELD Flat Polyisocyanurate Insulation PRODUCT DESCRIPTION H-Shield is a,rigid ro cell "polyfsot:yan fiber reinfor� • Man H panel composed of a closed anufactured on-line to s oh each FEATURES AND BE red with NexGen Chemistr is Zero OOP, EPA Compliant, and ved for direct application to steel de ved u , .major roof covering ified andl f NEL !able k;'two grade M C Type II, • Single - Fully Ad _.. Standing Seam Metal ;Roof Systems` lified Bitumen Systems TS ntains no CFCs, virtually no GWP (1220mm x mm) and in cknesses " (25mm PLIC ONS ons requiring FM 1 and`UL Systems, lasted, Mec 'al Tar BUR, engths per 0 psi) or 12 Omm x " (114mm) A ratings ally Attached, H-SHIELD THERMAL VALUES THICKNESS (INCHES) (MM) 1.00 1.50 1 Rn 25 38 dt", 2.00 51 2.50 2.60 3.00 3.50 3.80 4.00 4.30 4.50 b4 66 76 89 97 102 109 114 LTTR R-VALUE* 5.6 FLUTE SPANABILITY 2 5/8" 8.6 4 3/8" 1 n 9 d R!R" 11.4 4 3/8" 14.4 15,0 17.4 20.5 22.3 23.6 25.5 26.8 4 Jiff 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" *NEW Long Term Thermal Resistance Values are based on ASTM C 1289, effective 1/1/2014, which provides updated 15 year time weighted averages. Codes and Compliances • ASTM C 1289 Type II, Class 1 Grade 2 (20 psi) or Grade 3 (25 psi) • International Building Code (IBC) Chapter 26 • State of Florida Product Approval Number FL 5968 • Miami Dade County, FL NOA NO: 09-0915.15 — Exp. 1.14.2015 Underwriters Laboratories Inc Classifications • UL 1256 • Insulated Metal Deck Construction Assemblies - No. 120, 123, 292 • UL 790 • UL 263 Hourly Rated P Series Roof Assemblies UL Classified for use in Canada • Refer to UL Directory of Products Certified for Canada for more details Factory Mutual Approvals • FM 4450, FM 4470 • Approved for Class 1 insulated steel deck constructions for 1-60 to 1-270. Refer to FM Approval's RoofNav for details on specific systems LEED Potential Credits for Polyiso Use (PRE LEED V4). For current LEED V4 contribution information go to www.PIMA.org or www.hpanels.com Energy and Atmosphere • Optimize Energy Performance • Measurement & Verification Materials & Resources • Material Reuse • Construction Waste Management • Recycled Content • Local and Regional Materials Innovation and Design W W W. H U N T E R P A N E L S. C O M 8 8 8. 7 4 6. I I 14 .H U N T E R PANELS ENERGY SMART POLYISO TYPICAL PHYSICAL PROPERTY DATA CHART PER ASTM C 1289 POLYISO FOAM CORE ONLY PROPERTY TEST METHOD VALUE Compressive Strength ASTM D 1621 20 psi* (138kPa, Grade 2) Dimensional Stability ASTM D 2126 2% linear change (7 days) Moisture Vapor Transmission ASTM E 96 < 1 perm (57.5ng1(Pa•s•m2)) Water Absorption ASTM C 209 < 1 % volume Service Temperature -100° to 250° F (-73°C to 122°C) Single -Ply Sysi d a Ballasted Singl Systems Each H-Shield l is looseiyl gger jointsrdjacent pan, manufacturers specifi /tilechenicallyched ch H-Shield el mu Adhered Sim H-Shield pat 12 Nl�rnum 4'x4'( a layi of insulation *Also available in 25 psi, Grade 3 he roof5deck.`Butt the roof covering a WARNINGS AND LIMITATIONS Insulation must be protected from open flame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof covering material. Hunter Panels will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. For more information refer to the Storage and Handling Technical Bulletin at www.hpanels.com, or refer to PIMA Technical Bulletin No. 109: Storage & Handling Recommendations for Polyiso Roof Insulation at www.polyiso.org. NSTALLATION s and ding to of deck with f ners and plates ecifications hewof deck wit 'of H-Shield steep aspha overing accor`i Built Up, Tar And Modified Bic Each H-Shield pa Maximum 4'x4' (122 m 1 rr to p subsequent layers of insulation with joints of adjacent panels. Install th eners and plates (appropriate to the deck be adhered to a prepared concrete de sulation adhesive or cold applied mastic o the manufacturer's specifications. terns. deck with fasteners and plates (appropriate to the deck type). anels of H-Shield may be adhered to a prepared concrete deck or a full mopping of hot steep asphalt, insulation adhesive or cold applied m e roof covering according to the manufacturer's specifications. H v N+ E R R-30,0, two layers of 2.6" H*Shiield wfth Single -Ply membrane stic Butt edges and sta Energy Smart Polyiso HUNTERPANELS,COM I5 FRANKLIN STREET, PORTLAND, ME 04101 • 888.746:1114 • FAX: 877.775.1769 PI alityMark" The Certified LTTR-valve PIMA LTISOCTANURATE INSULATION MANUFACTURERS ASSOCIATION (t PAPER r PRINTED WITH SOY INK er MIX FSC ..�°'wwew ,... DSC C102015 NEW YORK • ILLINOIS • FLORIDA • TEXAS • UTAH • PENNSYLVANIA • WASHINGTON 1213 e-ditv PRODUCT DATA SHEET PDS-365 -1111 SOPRENLA® ** Vapor Barrier Rev 02/09 SOPRALENE 180 SANDED SOPRALENE 180 SANDED (21) Order No. 00220 DESCRIPTION & APPLICATION Sopralene 180 Sanded base ply is composed of selected SBS modified bitumen applied onto a non -woven polyester reinforcement with sand on the underside and a high brush sanded topside surface. The Sopralene 180 Sanded field and flashing base membrane plies is adhered to a properly prepared, clean, dry and/or primed (where required) substrate by using the hot asphalt or cold adhesive application methods. Optional inner ply(s) or the field cap membrane ply is bonded to the properly prepared, clean, dry and/or primed (where required) Sopralene 180 Sanded top surface with the with hot asphalt or cold adhesive application methods. See published Specifications and Approved Details. COMPOSITION & PACKAGING Product/ Property SOPRALENE 180 SANDED Reinforcement polyester Elastomeric Bitumen selected blend of bitumen and SBS thermoplastic polymers Topside sanded Underside sanded Approximate Nominal Thickness 120 mils (3.0 mm) Approximate Roll Coverage 97.5 ft2 (9.1m2) Side Lap 3" (76 mm) End Lap 6" (152 mm) Roll Length 33 ft (10 m) Roll Width 39" (1 m) Approximate Roll Weight 77 Ibs (35 kg) Rolls per Pallet* 30 * Rolls stocked upright on pallets WARRANTY Contact your local SOPREMA representative for project warranty offerings. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 General product information is provided on this Product Data Sheet The physical property values reported here are based on testing conducted under controlled laboratory conditions according to accepted test standards. ratpSOPRALENE 180 SANDED PDS-365 EMAPAGE 2 Rev 02/09 PHYSICAL PROPERTIES Physical Property per ASTM D 6164, Type I, Grade S MD XD Tensile - Max Load at 0 t 3.6°F Ibf/in 117 83 Elongation at 0 ± 3.6°F % 29 22 Tensile - Max Load at 73.4 ± 3.6°F Ibf/in 70 70 Elongation at 73.4 t 3.6°F % 56 61 Tear Strength at 73.4 ± 3.6°F Ibf 120 87 Low Temperature Flex °F max -15 -15 Dimensional Stability % max <0.5 <0.5 Compound Stability Temp F 230 230 Granule Embedment g/max NA NA Minimum values before and after Heat Conditioning Test results for manufacturing plant in Wadsworth, OH APPROVALS See Underwriters Laboratories Inc. File #RI1436, FM Approvals, ICC/ES, Miami -Dade County or Florida Building Code Product Approval Listings for current Approved Roof Assembly combinations. Soprema is ISO-9001:2000 Certified. GENERAL SOPREMA is a Certified ISO 9001:2000 worldwide producer of bituminous membranes with factories in Europe and North America. Waterproofing sheets have been produced by SOPREMA since 1908. Today, through a special mixture of components, SOPREMA membranes redefine the qualities indispensable to a high performance roof membrane: elasticity, flexibility, heat & fatigue resistance. SOPREMA SBS modified bitumen membrane assemblies typically consist of base and top ply membranes that have specific type reinforcements in order to meet specific ASTM Standards. The two ply system provides a resistance to punctures and tears, as well as ensuring an effective distribution of stress points. The two ply system operates in a homogeneous fashion. The bitumen in each layer moves uniformly to offer continuous protection. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 General product information is provided on this Product Data Sheet The physical property values repotted here are based on testing conducted under controlled laboratory conditions according to accepted test standards. SOPREMA® PRODUCT DATA SHEET PDS-381 Rev 10/13 SOPRALENE 250 FR GR SOPRALENE 250 FR GR (47) Order No. 01965* *Cap sheet order numbers are for WHITE CAP SHEETS ONLY. Contact Customer Service or your Sales Representative for other available cap sheet colors and special order requirements. CR C(X)1. R(X)F RATING COI MEMBER DESCRIPTION & APPLICATION Sopralene 250 FR GR cap ply is composed of selected SBS modified bitumen applied onto a non -woven polyester reinforcement with sand on the underside and a colored granule topside surface. The Sopralene 250 FR GR field and flashing cap membrane ply is adhered to a properly prepared, clean, dry and/or primed (where required) base or ply membrane by using the hot asphalt or cold adhesive application methods. Note: Soprema recommends cold adhesive application only when ambient temperatures are over 50 F and rising, and the sheet has been unrolled and allowed to relax while exposed to warm temperaturees or direct sunlight for at least one hour prior to installation. See published Specifications and Approved Details. COMPOSITION & PACKAGING Product/ Property SOPRALENE 250 FR GR Reinforcement polyester Elastomeric Bitumen selected blend of bitumen and SBS thermoplastic polymers Topside colored granules Underside sanded Approximate Nominal Thickness 160 mils (4.0 mm) Approximate Roll Coverage 97.5 ft2 (9.1 m2) Side Lap 3" (76 mm) End Lap 6" (152 mm) Roll Length 33 ft (10 m) Roll Width 39" (1 m) Approximate Roll Weight 107 Ibs (50 kg) Rolls per Pallet* 25 * Rolls stocked upright on pallets APPROVALS See Underwriters Laboratories Inc. File #R11436, FM Approvals, ICC/ES, Miami -Dade County or Florida Building Code Product Approval Listings for current Approved Roof Assembly combinations. Soprema is ISO-9001:2008 Certified. WARRANTY Contact your local SOPREMA representative for project warranty offerings. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 Gaieralproduct intonation ispaidedmils Raid Data Sheet ThepfysicalprapertyvaluesreportedheearebasedontestingcadxtedudacutrdledId:oratoryca bersaooudrgbacceptedieststadard SOPRALENE 250 FR GR AMA® PAGE 2 PDS-381 Rev 10/13 PHYSICAL PROPERTIES Physical Property per ASTM D 6164, Type II, Grade G MD XD Tensile - Max Load at 0 ± 3.6°F Ibf/in 159 111 Elongation at 0 t 3.6°F % 33 28 Tensile - Max Load at 73.4 ± 3.6°F Ibf/in 136 99 Elongation at 73.4 ± 3.6°F % 54 59 Tear Strength at 73.4 ± 3.6°F Ibf 164 121 Low Temperature Flex °F max -15 -15 Dimensional Stability % max <0.5 <0.5 Compound Stability Temp F 230 230 Granule Embedment g/max 0.8 0.8 Minimum values before and after Heat Conditioning Test results for manufacturing plant in Wadsworth, OH SURFACE CHARACTERISTICS PRODUCT SOLAR REFLECTANCE') THERMAL EMITTANCE1�1 SRIt3 INITIAL 3 YEAR INITIAL 3 YEAR INITIAL 3 YEAR SOPRALENE 250 FR GR (WH) [Standard white granules]* 0.27 0.24 0.87 0.91 27 25 SOPRALENE 250 FR GR (SG) [Highly reflective white granules]** 0.70 PENDING 0.89 PENDING 86 PENDING * CRRC Rated Product ID Number: 0772-0011 ** CRRC Rated Product ID Number: 0772-0049 Initial reporting, results pending (1) ASTM C1549 (2) ASTM C1371 (3) ASTM E1980 Sopralene 250 FR GR includes the standard white granules. Contact Soprema Customer Service or your Sales Representative for other available granule color options and special order requirements. Sopralene 250 FR GR (WH) white granules: Order No. 01965 Sopralene 250 FR GR (SG) highly reflective white granules: Order No. 01976 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 General product information is provided on this Product Data Sheet The physical property values reported here are based on testing conducted under controlled laboratory conditions according to accepted test standards. HT (kg) COVERAGE (gal) COVERAGE ( EULLY CURED lb) per it10?t? per icyer per layer �f( {� ' 35°C) � d8°F (20°C) : al b8"E (�©'C) r7f �t$°l• (Zn°C) ,+pt, b8°i= ( DESCRIPTION Alsan Flashing is a proprietary formulation liquid membrane solution for flashing and upstand applications. Alsan Flashing is also utilized in recovery applications over existing modified bitumen and built-up roof membrane systems. PREPARATION Stir Alsan Flashing prior to application. APPLICATION Alsan Flashing is applied with rollers, brushes and squeegees. For flashing applications, apply Alsan Flashing at a rate of 2.0 gallons per 100 ft2 onto prepared substrate. Immediately center and embed Alsan PolyFleece reinforcement at the transition change into wet Alsan Flashing. Apply an embedment application of Alsan Flashing at a rate of 2.0 gallons per 100 ft2, ensuring that the PolyFleece is completely embedded, covered and watertight. Allow to dry. Apply a final finish application of Alsan Flashing at a rate of 2.0 gallons per 100 ft2. Alsan Flashing can be left exposed or ceramic granules can be broadcast into this final Alsan Flashing coat prior to skinning over of the product. See published specifications and approved details. PACKAGING Alsan Flashing is available in five (5) gallon and one (1) gallon cans. STORAGE Store containers in a cool, well -ventilated area, out of direct sunlight and away from humidity, heat and ignition sources. Keep storage areas clear of combustible materials. No smoking near storage area. Tightly seal all partially used containers. HANDLING Do not smoke. Avoid contact with eyes, skin and clothing. Consult the Material Safety Data Sheet for additional information pertaining to this product. COVERAGE RATES FLASHING SYSTEM APPLICATION Property PHYSICAL PROPERTIES Value Test Method DESCRIPTION Alsan PolyFleece is a proprietary weave polyester reinforcement used in conjunction with Alsan Flashing and other Alsan liquid applied resins. (Note: Please refer to Alsan RS Fleece product data sheet for information regarding reinforcing fabric utilized in Alsan RS fully reinforced system applications). PREPARATION Prepare Soprema liquid -applied resins in strict accordance with published instructions. APPLICATION Mix and apply Soprema Alsan products in strict accordance with published instructions. Apply mixed resin liberally to the prepared surface with a roller using a broad, even stroke. Roll out Alsan PolyFleece into the liquid resin, making sure that the roll is unrolling smooth and without any wrinkles or fish mouths. Alsan PolyFleece will begin to saturate into the liquid resin. Using a roller, wet the fleece with resin applying light pressure. Roll the fleece with a nap roller to eliminate any air bubbles, wrinkles, etc. Apply additional liquid resin mix on top of Alsan PolyFleece until fully saturated and the layer of resin is fully and evenly applied. The coat should be smooth and uniform. See published specifications and approved details. PACKAGING Alsan PolyFleece is available in rolls 50 feet (15.2 meters) in length and four (4) inch, six (6) inch and eight (8) inch widths. STORAGE Always store in a dry location protected against the elements. Store on end to avoid deforming rolls and creasing fabric. Property PHYSICAL PROPERTIES Value ail 7 Johns Manville FesCant'M Plus Cant Strip Tapered Fesco® Edge Strip Perlite-Based Specialty Accessory Product Features and Components Expanded Perlite: Provides good dimensional stability and excellent insulation value with stable R-value. The high perlite content offers far greater fire resistance than conventional wood fiber materials. Reinforcing Cellulosic Fibers: Consists of recycled newsprint to provide strength to the board as well as high recycled content. JM utilizes third party certification by UL® environment to certify the recycled content and contributes to the LEED® Materials and Resource (MR) credit 4. FesCant Plus Cant Strips: Manufactured from JM Cant Board, a high -density, laminated perlite board that provides excellent transition from the deck to the wall of the roof. Tapered Fesco Edge Strips: Excellent for transitioning from membrane to nailer, or transitioning from Tapered Fesco®, Tapered ENRGY 3®, or Tapered Fesco Foam panels to the roof level to help promote positive drainage. • Expanded Perlite • Reinforcing Cellulosic Fibers • Selected Binders Component Multi -Ply Type System Compatibility This product may he used as a component in the following systems. Please reference product application for specific installation methods and information. BUR HA CA APP CA HW SBS HA CA NW Compatible with the Multi -Ply systems selected above Do not use in Single Ply systems Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Self Adhered MF = Mechanically Fastened FA = Fully Adhered BA = Ballasted Energy and the Environment Cant Strip: 39% average Edge Strip: 33% average For post and pre -consumer recycled content percentages, visit the Fesco Board product page on the JM roofing Web site. CLAIMSENVIRONMENTAL VALIDATION FosCamPlus Cant Strip r.ont ants en average of 39",rocycled cuntent. ENVIRONMENTAL e Taltnrhd I'oscu FdgStrip CLAIMSamain, an avn lag' nl VALIDATION 33"' cuntont Peak Advantage® Guarantee Information stems x a. Guars.t When used in most JM multi -ply or single ply systems. 10,15 or 20 years * Contact JM Technical Services for specific systems or terms over 20 years. Codes and Approvals 1,58IF�F c US APPROVED MIAMEDADE COUNTY APPROVED Miami -Dade County Product Control Approved Refer to the Material Safety Data Sheet and product label prior to using this product. The Material Safety Data Sheet is available by calling (800) 922-5922 or on the Web at www.jm.com/roofing. Installation/Application of sp a t dl, pp te. Urethsne Adhesive Referto the Application Guides and Detail Drawings for instructions. Packaging and Dimensions FesCant Plus Cant Strip 1"x3" 1„x4" 1.5"x4" 1.5'x5' +' 33 21 30 18 30 30 20 20 t` 120 84 120 72 20 20 30 30 600 48 „u r Tapered Fesco Edge Strip 0.5"x6" 0.5"x12" 1"x12" 1"x18" 1.5"x12" 1.5"x18" e y 72 36 28 18 12 12 a 'fir, 14 14 10 10 16 10 " 288 144 112 72 48 48 r 0 36 36 56 54 36 54 7 P 60 35 93 50 60 60 Y A SLR'. 840 490 933 500 960 600 48 Rockdale, IL *Assumes 48 flatbed truck. RS-5049 2-14 (Replaces 7-13) Johns Manville FesCant' Plus Cant Strip Tapered Fesco® Edge Strip Perlite-Based Specialty Accessory Product Typical Physical Properties* Test ASTM FesCant Plus Cant Strip* Tapered Fesco Edge Strip* Product Density, pcf (kg/m3) C 209 12 (192) 9 (144) Compressive Strength, psi (kPa) 5% Consolidation 10% Consolidation C 165 35 (241) 50 (345) 30 (207) 40 (276) Laminar Tensile Strength, psi (kPa), min C 209 4.9 (34) 7 (48) Flexural Strength, psi (kPa) C 203 60 (414) 65 (448) Water Absorption, % by vol (2 hr), max C 209 3.5 1.5 Linear Expansion, % max C 209 0.5 0.5 *FesCant Plus Cant Strip is manufactured from IT Perlite board in ASTM C 728, Tapered Fesco Edge Strip is manufactured from 3t' Perlite board in ASTM C 728. Thermal Performance Test Flame Spread ASTM FesCant Plus Cant Strip Tapered Fesco Edge Strip E84 30 25 Smoke Developed E84 20 10 Refer to the Material Safety Data Sheet and product label prior to using this product. The Material Safety Data Sheet is available by calling (8001922-5922 or on the Web at www.jm.com/roofing. RS-5049 2-14 (Replaces 7-13) HNICAL DATA .5." DESCRIPTION Soprasphalte M is an SEBS-modifed asphalt used to adhere SBS-modified bitumen membranes in roofing construction. Soprasphalte M is specially formulated to have high tensile strength, high recoverable elongation, cold temperature " exibility, good flow resistance and greater thermal stability when compared to conventional oxidized roofing asphalt. APPLICATION Application temperature: The product must be at a minimum of 428°F (220°C) on contact with roll roofing sheet. Soprasphalte M must not be heated at temperatures above 500°F (260 °C) as product will deteriorate. Product must be continously in movement in kettle during heating. See published specifications and approved details. DATA SHEET Property PRODUCT PROPERTIES Value Standard Adttesion'time. n oftening°te Flash "point ;; Penetration Penetration Solids by weigh Solubility in ICE Elongation Elastic recovery: Low temperature initial °C, offer$°#tr ,:2`60°C exib lity' mediate and4 212°F (1 -4 ,F (.20°C)' ASTM ©6152 ASTMDb152 STM p 6152, AM D 6152 ATM D b 1 2 ASTM ASTM 61 ** To adhere insulation only. CONTINENTAL MATERIALS, INC Fasteners • Asphalt • Underlayments • Fiberboard • Tools Introducing CMI-PAKTM with No-SmeIITM technology... brought to you by the US innovators of easy -handle consumable asphalt packaging. For over 50 years, CMI has been providing industry -leading quality roofing products. Now bringing you CMI-PAKT' with a strong and time -tested protective wrapping eliminating waste and enhancing productivity. -PAK'm ...with \o-SmeHTM Technology! "Quality Manufactured Components... Making Construction Systems Perform Better Since 1958" Your Best Choice For Asphaltiust Got Better... And EASIER! • Easier to handle...Only 50 lbs. per Pak, won't break your installers' backs • 100% consumable...Packaging dissolves, so no wrappers left to clean up afterwards • Safer... No chopping necessary and no flying asphalt shards • Less mess...No shards to be tracked around the job site or into the building • More productivity...2400 lbs. per pallet, so less pallets to handle and store CMI-PAIr has all of the great features you've come to expect from CMI No-SmellTmAsphalt.. • No more odor complaints... Patented XyClene" Technology encapsulates the low -end asphaltenes (that produce odor) making the asphalt smell virtually unde- tectable to workers, building occupants, and neighbors • Ready to use...The No -Smell is factory mixed to assure maximum effectiveness; no messy or dangerous additives need to be added at the kettle • Eliminates scheduling hassles... Roofing can be performed even if building is occupied • Superior to competitive technologies...that only mask the odor (like using perfume) or that have an offen- sive smell • Meets or exceeds ASTM D312...The industry stan- dard for high quality asphalt for built-up roofing • Proven performance... Independently tested to assure long term asphalt integrity • Weather Sear pallet cover... Protects against ice, water, and debris for up to 6 months \o-SmeIITM Asphalt "Why Mask The Odor... When You Can Encapsulate It!" Cartons • ASTM and EVT data on every carton... Every carton is clearly marked for convenience • Weather Seal" pallet cover... Protects against ice, water, and debris for up to 6 months; also keeps the asphalt cartons cool (and pallets stable) in hot weather • Superior storability... UV -resistant protective cover is perfect for the warehouse or at the job site Physical Properties/Specifications (All MI asphalt meets or exceeds ASTM D-312 equirements) ASTM Test Method Typel Typell Type!!! Type IV Min Max Min Max Min Max Min Max Softening Point 0-36 135 151 158 176 185 205 210 225 Flash Point (° F) D-92 500 - 500 - 500 - 500 - Penetration, Units: at 32" F D-5 3 - 6 - 6 - 6 - at77°F D-5 18 60 18 40 15 35 12 25 at115°F D-5 90 180 - 100 - 90 - 75 Ductility at77`F, cm D-113 10 - 3 - 2.5 - 1.5 - %solubilityin trichloroethylene D-2042 99 - 99 - 99 - 99 - CONTINENTAL MATERIALS. INC No -Smell' Asphalt Virtually eliminates objection- able asphalt odors during the installation —so complaints from occupants and the neighbors disappear. XyC/eneTM Bulk • Improves productivity... No time wasted melting packaged asphalt • Economical... Less expensive to use (on a total acquisition cost basis) than packaged asphalt Asphalt Hooting Manufacturers Association Weather Seal'" pallet cover protects against the elements for up to 6 months! The Secret Behind Proprietary Xyclene'• No -Smell Technology Unlike cheap imitations, No -Smell" Asphalt doesn't just contain a mask- ing agent. Its proprietary Xyclene" formula is a true odor suppressant. It acts at the molecular level as an oxygen scavenger to retard the release of specific odor -causing compounds. The Xyclene" formula encapsulates asphaltenes, stopping the evaporation of lighter petroleum molecules and eliminating fumes. It is your best answer to asphalt roofing odors at the kettle, and more importantly, on the roof. "Quality Manufactured Components... Making Construction Systems Perform Better Since 1958" Fiberboard Your best choice for reliable performance in asphaltic or single ply roofing systems. It's even environmentally -friendly! s;7010 Continrnlal valnrials, Inc. Y110. 1614 Old York Roar? • Abington, PA 19001 • (800) 247-5637 Underlayments 1 30 Top quality synthetic and asphaltic underlayments at prices you can afford — and with quality that you can rely on every day. Fasteners Superior value has made us one of the largest and fastest -growing fastener suppliers in North America — for more than half a century! Application Tools Ultra -high purity, 100% cotton mops deliver long-lasting performance and the perfect balance between cost and service life. visit us at www.continentalmaterials.com Hercules' RetroDrain PRODUCT DATA SPECIFICATIONS PRODUCT DESCRIPTION One-piece spun aluminum body and heavy duty cast aluminum strainer dome and clamping ring provide strength and durability. The drain flange has a depressed sump area to facilitate water drainage from the roof surface. The Hercules RetroDrain incorporates U-Flow® Seal technology for a mechanical watertight connection to PVC or cast iron pipes to prevent water from backup damage. Available in 3-in., 4-in., 5-in. and 6-in. sizes. FEATURES & BENEFITS • One piece seamless body provides strength and durability without separation of the flange from the stem. • Extra large flange allows positive attachment of roof flashing membrane while the sump area facilitates drainage. • Simple and easy to install from rooftop in 15 to 30 minutes. • Cast aluminum strainer dome and clamping ring. • 12-in. long drain stem accommodates most existing field conditions with longer lengths available. • Incorporates U-Flow Seal technology for a secure, watertight connection. OMG. ROOFING PRODUCTS • Also available with a plastic dome or the cast -aluminum SuperDome. • Saves time and money by allowing easy installation from the rooftop without disturbing occupants. APPLICATION OlyFlow® RetroDrains are designed to replace existing drains in reroofing applica- tions. Installed from the roof surface, OlyFlow RetroDrains are engineered to be installed without removing the existing plumbing or fixture while providing a watertight connection to the roof system and the existing plumbing. APPROVALS & STANDARDS S R 9wF Per Roca Mwsm ANSI/SPRI RD-1 is a national perfor- mance standard for retrofit roof drains. While most retrofit drains are not tested to this standard, OlyFlow Insert Drains — including the Hercules RetroDrain with U-Flow Seal — exceed the standard, which requires that the seal hold a 10-ft. column of water for 24 hours without leaking. 153 BOWLES ROAD, AGAWAM, MA 01001 800.633.3800 WWW.OLYFAST.COM INFO@OLYFAST.COM Hercules®, RetroDrain®, OlyFlow®, Superpome®and U-Flow are trademarks of OMG, Inc. Copyright © 2011 OMG, Inc. All rights reserved. PHYSICAL DATA The data below is constant for each Hercules RetroDrain. DRAIN BODY 11 gauge (.125") spun aluminum FLANGE 17Y2" diameter with sump area STEM 12" length SEAL Watertight U-Flow mechanical seal requires U-Flow screwdriver STRAINER DOME Cast aluminum, plastic or aluminum SuperDome CLAMP RING Cast aluminum ORDERING INFORMATION CAT. NO. HDAL3A HDALSA SIZE DOME TYPE Aluminum en= DIMENSIONAL PKG WEIGHT Each Each 32 lbs. 32 lbs. RP110856 Rev.0911 Hercules° RetroDrain INSTALLATION PROCEDURE FOR USE WITH All types of roof covers. JOB PREPARATION Remove existing strainer dome and clamping ring. Remove other existing drain components as required to enable Hercules Drain flange to lie flush on roof membrane. Remove any debris or constricting materials in the existing drain pipe that interferes with proper installation. STEP 1 Hercules Drain Body U-Flow Seal • . . -` Existing Drain��y Existing Pipe --� Roof Membrane Examine the existing water leader to make sure there are no elbows that prevent the drain stem from being fully inserted into the pipe. (If an elbow is present, see "How to Shorten a Drain.") Insert U-Flow® Seal into end of drain stem and tighten screws enough to hold the seal in place during installation. Insert assembled drain into existing leader pipe until flange lies flush on roof membrane. STEP 2 Alternately tighten seal compression ring screws with U-Flow Screwdriver until hand tight. Hercules Drain body is correctly installed when pressure placed on drain body results in no vertical movement. Do not overtighten the screws. STEP 3 Flashing Membrane (Refer to project specifications) �Ii^Ii IIIII�� I Secure the drain flange to the roof deck/nailer using a minimum of three pan -head fasteners, evenly spaced around the flange. The flashing membrane must cover and extend past the fas- tener head. Flashing membrane must be installed per roof membrane manufacturer's detail. OMG. ROOFING PRODUCTS 153 BOWLES ROAD, AGAWAM, MA 01001 800-633.3800 WWW.OLYFAST.COM INFO@OLYFAST.COM Hercules", RetroDrain', OlyFlow' , SuperDomeand U-Flows' are trademarks of OMG, Inc. Copyright © 2011 OMG, Inc. AM rights reserved. STEP 4 Place clamping ring over metal studs. Install stainless steel nut and lock washers tightening clamping ring against membrane flashing until secure. STEP 5 nstall strainer dome by aligning screw holes with the holes in the clamping ring. Secure with screws provided. HOW TO SHORTEN AN OLYFLOW RETROFIT DRAIN ake sure there is atieast 4-inches of clear vertical distance in the existing pipe to accommodate the drain. Cut drain stem to desired length and insert U-Flow Seal. Note: Leave at least 2.5-inches of the drain stem ommodate the seal, Insert the U-Flow Seal in the cut drain stem and tighten the seal screws. Once the drain and seal have been assembled, insert it into the existing water leader and complete the assembly following installation steps 2 thru 5. For technical assistance contact OMG at 800.633.3800. Roofing Read Material Safety Data Sheets before using this product. 14 19 Ultra Rubberized Flashing Cement (wet/dry) DESCRIPTION: Karnak #19 Ultra Flashing Cement is the next generation asbestos -free flashing cement. Scientifically compounded with a selection of rubber reinforced asphalt, mineral fibers, and refined solvents. Karnak #19 Ultra is manufactured to a heavy pliable consistency for ease of application by trowel. #19 Ultra provides a durable elastomeric coating of greater strength, excellent adhesion and high resistance to water and weathering. Karnak #19 Ultra is composed of special chemical ingredients which give it a unique water displacement quality (Wet/Dry). Karnak #19 Ultra dries to a tough, flexible, waterproof and corrosion proof rubber coating which gives maximum protection and excellent performance over wide ranges of temperature and weather conditions. Karnak #19 Ultra is available in 3 consistencies: Summer, Semi and Winter. FEATURES AND BENEFITS: • Rubberized - elastomeric • Wet or dry application • Improved low -temperature flexibility • Improved water and weather resistance • Will not shrink or crack • Smooth, easy to apply rubber -like trowel consistency • Excellent adhesion • Excellent resistance to flow (sag) at high roof temperatures • Ready to apply - no mixing required • Greater strength • Cures faster than regular flashing cements • VOC compliant • ASTM compliant • Sticks under water the first time. • Can be used with fiberglass membrane under water. PHYSICAL PROPERTIES: 1. Consistency: A smooth rubber -like trowel consistency which will readily spread on and adhere to vertical and horizontal surfaces without sagging. 2. Character of Dried Film: Excellent adhesion to masonry, steel, cured concrete, shingles, asphalt roofing, skylight flashings and a variety of other surfaces. KARNAK 330 CENTRAL AVENUE, CLARK, NJ 07066 732-388-0300 • 800-526-4236 • FAX: 732-388-9422 WEB: http://www.karnakcorp.com APROvED, FM1010 Roofing Read Material Safety Data Sheets before using this product. 19 Ultra Rubberized Flashing Cement (wet/dry) 3. Film Performance Characteristics: The dried film retains its elasticity and ductility so that the material will resist extreme variations in temperature and weather. 4. Sag Resistance: Excellent resistance to flow at high roof temperatures on vertical surfaces. 5. Homogenized: Thoroughly mixed and consistent throughout. 6. Consistency: 19 Ultra is always smooth and of a trowel consistency. USES: Karnak #19 Ultra Flashing Cement is a general purpose asbestos -free flashing cement for repairing leaks in shingles, concrete, metal or asphalt roofs, SBS and APP modified bitumen membranes flashings on walls, chimneys, flues, skylight flashings, downspouts and cornices. 19 Ultra is excellent for sealing cracks in concrete and brick, as a joint filler for precast roof slabs, for repair, patch and flashing detail on SBS and APP modified membranes, and for general purpose use in maintenance of exposed buildings and structures. SPECIFICATIONS: ASTM D-4586 Type I Class I & Class II ASTM D-3409 Fed Spec SS-C-153 Type I (Asbestos -Free) SURFACE PREPARATION: All surfaces should be clean, dry and free from oil, grease, dust, dirt, loose paint or other foreign matter. Excess water should be removed, if possible, before application of #19 Ultra. APPLICATION: Spread Karnak #19 Ultra Flashing Cement to an average thickness of 1/8" (approximately 8 gallons per square) and press tightly into joints, seams or cracks. TO REPAIR CRACKS, BREAKS AND BLISTERS: 1. Spread Karnak #19 Ultra Flashing Cement over the damaged area at an average thickness of 1/8". 2. Embed Karnak Cotton, Glass or Polyester Membrane reinforcement in the #19 Ultra Flashing Cement. 3. Apply an additional coat of Karnak #19 Ultra Flashing Cement over the entire patch at an average thickness of 1/8". KARNAK 330 CENTRAL AVENUE, CLARK, NJ 07066 732-388-0300 • 800-526-4236 • FAX: 732-388-9422 WEB: http://www.karnakcorp.com a,Fao,EO FM1010 15 0 0 Roofing Read Material Safety Data Sheets before using this product. 19 Ultra Rubberized Flashing Cement (wet/dry) 0) o CAUTION: Combustible Mixture: do not use near open flame. Avoid breathing solvent fumes and prolonged contact with skin. Do not take internally. If swallowed, do not induce vomiting. Call a physical immediately. Keep out of reach of children. Keep container covered when not in use. Do not thin. Consult MSDS for further safety precautions. Dispose of in an environmentally safe manner. Cover air intakes during application and while drying. 16 CARE OF TOOLS: Tools and other equipment should be thoroughly cleaned with mineral spirits, taking necessary precautions when handling combustible materials. To clean hands use #709 Karnak Karna-Klean or a waterless hand cleaner. PACKAGING: Available in 1 gallon cans, 3 gallon buckets, 5 gallon pails and 10.1 oz.cartridges. If further information is needed, contact Karnak Technical Services at 1-800-526-4236. Please see page 212 for additional mold and safety information. 'UMIAK 330 CENTRAL AVENUE, CLARK, NJ 07066 732-388-0300 • 800-526-4236 • FAX: 732-388-9422 WEB: http://www.karnakcorp.com APFROvED FM1010 DBASF The Chemical Company SONOLASTIC® NP1 TM Polyurethane joint sealant DESCRIPTION Sonolastic NP 1 is a versatile moisture -curing high performance polyurethane sealant with permanent elasticity. RECOMMENDED FOR Active, vertical and horizontal interior, exterior joints. Including expansion wall joints, floor and pavement joints, curtain walls, panel walls, precast walls, window frames, structural components, dams, spillways and stormwater drains. Substrates include concrete, masonry, aluminium and wood. FEATURES AND BENEFITS • Joint movement capability ± 35% Excellent flexibility for keeping moving joints tight • Available in pro -pack sausages Reduces job -site waste, lowers disposal costs • Easy to gun and tool Speeds application and makes neater joints • Variety of colours Matches common substrates • Bonds to most construction primer Lowers installation costs • One component No mixing, less labour • Weather resistant Long-lasting weathertight seals • Wide temperature application range Suitable for all climates • Paintable polyurethane sealant Best choice for structures that may be repainted • Low VOC content User friendly for applicators • Suitable for non -chlorinated water immersion Potable water approved materials without PERFORMANCE DATA Property . Testd thO d . > VaKia �) Movement capability (MAF) ASTM C 719 ± 35% Tensile strength ASTM D 412 2.4 MPa Ultimate elongation at break ASTM D 412 800% Hardness at standard conditions (Shore A) ASTM C 661 25-30 Hardness after heat aging, max. Shore A:50 ASTM C 661 25 Tack free time (maximum 72 hrs.) ASTM C 679 Passes Stain and colour change ASTM C 510 None Volatile Organic Compounds (VOC) SCAQMD Method 304-91 48g/litre Service temperature range (°C) -40 to 82 Potable water certified AS/NZS 4020 1000m2/L The above data represents the information typically required to a verify performance. For the full and comprehensive list of performance data, refer to "Application Guide & Performance Data for Sonolastic® Polyurethane Sealants" available from your local BASF Construction Chemicals representative. COMPLIANCES • Federal Specification TT-S-00230C, Type II, Class A • Corps of Engineers CRD-C-541, Type II, Class A • ASTM C 920, Type S, Grade NS, Class 25, Use NT, M, A, G and I • Canadian Specification CAN/CGSB-19 13-M87, Classification MCG-2-25-A-N, No.81026 • USDA approved for use in meat and poultry areas • Canadian approval for use in establishments that handle food • SWRI validated • ISO 11600 F-25LM ESTIMATING DATA Jalr�t Sloe' (rnn) Metres per: 5x5 40 10 x 10 10 12 x 12 6.95 15 x 7.5 8.88 20 x 10 5.00 25 x 12.5 3.20 30 x 15 2.22 APPLICATION For information on joint design, surface preparation and priming, refer to Technical Note 17 "Application Guide & Performance data for Sonolastic Polyurethane Sealants" available from your local BASF Construction Chemicals representative. Application • Sonolastic NP 1 comes ready to use. Apply by professional caulking gun. Do not open sausages until preparatory work has been completed. • Fill joints from deepest point to the surface by holding a properly sized nozzle against the back of the joint. • Dry tooling is recommended. DO NOT use soapy water when tooling. Tooling results in the correct bead shape, a neat joint, and maximum adhesion. DBASF The Chemical Company SONOLASTIC® NP1 TM For Best Performance • Protect unopened containers from heat and direct sunshine. • In cool or cold weather, store container at room temperature for at least 24 hours before using. • Do not apply over freshly treated wood; treated wood must have weathered for at least 6 months. • UV exposure may cause white Sonolastic NP 1 to discolour — this does not effect sealant performance; where maintaining a true white appearance is critical, use Sonolastic Ultra Sealant. • Temperatures below 5°C will extend curing times. • Sonolastic NP 1 should not come in contact with oil - base caulking, silicone sealants, polysulfides, fillers impregnated with oil, asphalt, or tar. • Sonolastic NP1 can be painted over provided it is fully cured and cleaned. When painting over any elastomeric sealant, use a paint that is also elastomeric. • Do not allow uncured Sonolastic NP1 to come into contact with alcohol -based materials or solvents. • When Sonolastic NP1 is to be used in areas subject to continuous water immersion, cure for 21 days at 23°C and 50% relative humidity. Allow longer cure times at lower temperatures and humidities. Always use Primer 733. • Do not use in swimming pool or other submerged conditions where the sealant will be exposed to strong oxidizers. • Avoid submerged conditions where water temperatures will exceed 50°C. CURING The cure of Sonolastic NP 1 varies with temperature and humidity. The following times assume 24°C, 50% relative humidity, and a joint 12mm width by 6mm depth. • Skins ovemight or within 24 hours. • Functional within 3 days. • Full cure in approximately 1 week. Note: Deeper joints require longer curing period. Lower tem•eratures and humidities will extend curin_ times. CLEANING • Immediately after use, clean equipment with Sonoshield Thinner. Use proper precautions when handling solvents. Remove cured sealant by cutting with a sharp -edge tool. Remove thin films b abradine. COLOURS A complete line of standard colours is available including white, limestone, tan, aluminium •re , and black. PACKAGING Sonolastic NP 1 is packaged in 590 mL ProPack sausages, 20 sausages to a carton. SHELF LIFE Shelf life is 12 months when stored away from heat and direct sunshine. PRECAUTIONS KEEP OUT OF REACH OF CHILDREN. Use only with adequate ventilation. Prevent contact with skin, eyes, and clothing. Wash thoroughly after handling. Use impervious gloves, eye protection and if used in a poorly ventilated area, use approved respiratory protection. First Aid In case of eye contact, flush thoroughly with water at least 15 minutes. SEEK IMMEDIATE MEDICAL ATTENTION. For the full health and safety hazard information and how to safely handle and use this product, please make sure that you obtain a copy of the BASF Construction Chemicals Material Safety Data Sheet (MSDS) from our office or our website. S SonNP1/11/0509 STATEMENT OF RESPONSIBILffY The technical information and application advice given in this BASF Construction Chemicals publication are based on the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is responsible for checking the suitability of products for their intended use. BASF Construction Chemicals data sheets are updated on a regular basis and it is the user's responsibiity to obtain the most recent issue. NOTE Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for carrying out procedures appropriate to a specific application. BASF Construction Chemicals offices in ASEAN Singapore Tel: +65-6861-6766 Fax: +65-6861-3186 Malaysia Indonesia Tel: +60-3-5628-3888 Tel: +62-21-526-2481 Fax: +60-3-5628-3776 Fax:+62-21-526-2541 Website: www.ap.cc.basf.com Thailand Tel: +66-2-664-9222 Fax: +66-2-664-9267 Vietnam Tel: +84-650-374-3100 Fax: +84-650-374-3200 Philippines Tel: +63-2-889-4321 Fax: +63-2-889-4361 t a Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofino.com 1 i{ li.( Ill IUil 0.4,. I.A %% CERTIFICATIONS 3 The Building Envelope Company March 12, 2014 SOPREMA AUTHORIZED APPLICATOR (WA037) Wayne's Roofing Inc. 13105 Houston Road Sumner, WA 98390 Tel: 253.863.4455 RE: SOPREMA AUTHORIZED APPLICATOR To Whom It May Concern; Please be advised that Wayne's Roofing Inc. of Sumner WA is a SOPREMA Roofing, Liquids and Waterproofing applicator, authorized to install SOPREMA Roofing, Liquids and Waterproofing systems that can qualify for SOPREMA warranties. Please contact SOPREMA if additional information is needed. Sincerely, Andrew Schwab SOPREMA Internal Technical Coordinator www.SOPREMA.us Telephone: 503.403.8184 aschwab@SOPREMA.us cc: Project File Sales and Technical Staff, SOPREMA Confidentiality Notice: This message is a private communication and may contain confidential information. If you are not the intended recipient, please do not read, copy, or use it, and do not disclose it to others. Please notify the sender of the delivery error by replying to this message and then delete it from your system. Thank You. 310 QUADRAL DRIVE • WADSWORTH, OH 44281 • Ph.330.334.0066 • Toll Free 800.356.3521 • Fax 330.334.4289 • WWW.SOPREMA.US UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R11436 Roofing Systems SOPREMA INC. Class A - Fully Adhered 88. Deck: NC Incline: 1/2 Thermal Barrier (Optional): — Gypsum or gypsum fiber (min 1/4 in.), perlite or mineral wool (min 3/4 in.), cement board (min 1/4 in.) or wood fiberboard (min 1/2 in.) mechanically fastened or adhered with any UL Classified insulation adhesive. Vapor Retarder (Optional): — Any UL Classified or Soprema base sheet, ply sheet or Sopravap'r, mechanically fastened or adhered. Base Sheet (Optional): — One or more plies Type G1 or Type G2; "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G" or "Modified Sopra G", any combination mechanically fastened or adhered with tiot asphalt. Insulation (Optional): Polyisocyanurate, polystyrene (EPS, XPS), glass fiber, mineral wool, perlite, wood fiber or cellular glass insulation, any thickness, any combination, mechanically fastened, loose laid or adhered with hot asphalt or insulation adhesive. NOTE: Polystyrene insulation must be covered with minimum 1/4-in. thick G-P Gypsum Corp. "DensDeck ® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Prime 2TM Roofboard" or "DensDeck DuraGuard® Roofboard" or Certainteed Gypsum Inc "GlasRoc" or USG Corp. SECUROCK® Glass -Mat Roof Board (Type SGMRX)". Barrier Board (Optional): — "Sopraboard" (min 1/8 in.), "SopraRock MD" or "SopraRock MD Plus" (min 1/2 in.), perlite (min 1/2 in.), gypsum or gypsum fiber (min 1/4 in.) or (min 1/2 in.) mechanically fastened, hot mopped or adhered with any UL Classified insulation adhesive. Base Sheet (Optional): — One or more plies Te G1 or Type G2; "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G" or 'apModified Sopra G", any combination mechanically fastened or adhered with hot asphalt. Ply Sheet (Optional): — One or more plies "Elastophene Sanded", "Elastophene HD", "Elastophene HR Sanded", "Elastophene HS FR", "Elastophene HP",I"Elastophene 180 Sanded", "Sopralene 180 Sanded", "Sopralene 250 Sanded", "Elastophene PS", "Elastophene 180 PS", "Sopralene 180 PS", "Sopralene 250 PS", "Elastophene HS", "Elastophene HS 62"or "Soprabase S" adhered with hot asphalt or mechanically fastened; or "Elastophene Flam", "Elastophene Flam 2.2 mm", "Elastophene Flam HD", "Elastophene Flam HR", "Elastophene Flam HS FR", "Elastophene Flam HP", "Sopralene Flam 180", "Sopralene Flam 250", "Elastophene Flam HS," "Elastophene Flam HS HD," "Colvent TG" or "Soprabase TG" heat welded or mechanically fastened; or "Soprafix", "Soprafix X" or "Soprafix E" mechanically fastened; or "Sopralene Stick", "Sopralene Flam Stick", "Colvent SA" or "EPS Flam Stick self -adhered. Cap Sheet: —I"Elastophene FR GR", "Elastophene HD FR GR", "Elastophene HR FR GR", "Elastophene HS FR GR", "Elastophene HP FR GR", "Elastophene LS FR GR", "Sopralene 180 FR GR", "Sopralene 180 FR GR 3.5 mm" or "Sopralene 250 FR GR" adhered with hot asphalt; or "Elastophene Flam FR GR", "Elastophene Flam HD FR GR", "Elastophene Flam HR FR GR", "Elastophene Flam HS FR GR", "Elastophene Flam HP FR GR", "Elastophene Flam LS FR GR", "Sopralene Flam 180 FR GR", "Sopralene Flam 180 FR GR 3.5 mm" or "Sopralene Flam 250 FR GR" heat welded; or "Colphene FR GR" or "Elastophene Stick FR GR," self -adhered. wood fiberboard A Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofinq.com 44l1\tom Ic11(II1\l., 1\I i WARRANTIES 4 • 4 IS SOPRON'. Warranty No.: 101-000000 Platinum NDL Roof Warranty Building Name: Building Address: Roof Section: Owner Name: Owner Address: Contractor: Total Squares: Roof Material: lashing Material: Term of Warranty: 10 Years Warranty Start Date: rantyAbil Date: Express Warranty SOPREMA, Inc., an Ohio corporation, warrants to you watertight for the full term of this warranty. This warran limitations set forth below. Reporting Claims To report a claim, follow the procedure set forth Remedy When you make a valid claim, SOPREM system to a watertight condition. NOTICES THE WARRANTY EXPRES WARRANTIES, WHETHER LIMITATION, ANY WARRAN PURPOSE. THE ABOVE-STA EDY IS IN NO EVENT IS S INCIDENT: CONSE This w document i The Term Form 900 THIS DO OR O i t - •ur SOPRE .f systeill remain is - ubject to all th. s : itions, and rranty P • ure. and material necessary to return the roof S AND IS IN LIEU OF ALL OTHER IMPLIED, INCLUDING, WITHOUT R FITNESS FOR ANY PARTICULAR XCLUSIVE REMEDY AGAINST SOPREMA. U OR ANY OCCUPANT OF THE BUILDING FOR ANY OTHER SIMILAR DAMAGES. owing: ions an• imitations printed on the reverse. anty Claim Procedure. and Maintenance Guide. This warranty is not vali • it ated. To be activated, it must be signed by Owner and retumed to SOPREMA within three mi s after the warranty start date. Until activated, the warranty is not binding against either party. SOPREMA, Inc. Owner: By: By: Name: Title: Date: Name: Title: Date: (Form 101) (07/2013) Terms, Conditions and Limitations 1. The components of your roof system covered by this warranty (the "Warranty") are the roof material and flashing material specifically identified by number or other description on the face of this Warranty. 2. The authorized contractor who installed the roof system is not an agent of SOPREMA. Any future work impacting the roof system must be performed by a contractor selected and hired by Owner and authorized by SOPREMA. Contact SOPREMA if you would like to receive a list of authorized contractors in your area. 3. The design and installation of the roof system and all other components must be in accordance with applicable instructions, details, specifications, approvals, codes, laws, and regulations. All services conducted by SOPREMA related to design, construction, review of project conditions and on -site inspections are limited in scope and do not expand the provisions of this Warranty. Accordingly, these services were not offered, and should not be considered, as a substitute for fulitime quality assurance, project management or professional design services. 4. Owner is responsible for ensuring that the roof system is maintained in accordance with SOPREMA's Care and Maintenance Guide (see Form 901) and for promptly notifying SOPREMA of any change in occupancy usage or any condition adversely affecting the roof system. 5. During the entire term of the Warranty, upon request, SOPREMA and any contractors it hires shall have full and free access to the roof. Access shall be provided during regular business hours, and, if requested in advance, any other times. 6. This Warranty covers a properly designed and installed roof system that develops a leak due to a manufacturing defect or contractor workmanship. The Warranty will provide Owner with a remedy when Owner follows the Warranty Claim Procedure (see Form 900) and the claim is validated by SOPREMA. 7. The roof system will not develop leaks from exposure to wind with a speed less than 74 m.p.h., as recorded by the National Weather Service data collection site located nearest to your building. 8. Following are some examples of conditions and types of damage that are not covered by the Warranty: a. The effects of lightning, fire, flood, acid rain, thermal shock, explosion, hail, seismic event, hurricane, tornado, or microburst. b. Improper use, order, sequencing, storage or handling of materials or systems. c. The lack of positive roof slope or inadequate drainage. d. Inaccessible leaks concealed below roof -supported equipment, overburden, and all other materials applied to the surface that are not part of the roof system. e. Failure to apply the roofing system, or any material below the roofing system, to a suitable substrate, or subsequent substrate failure. f. The failure of roof system substrates or attachment. g. A deficient pre-existing condition or any sources of water entry other than the roof system. h. Building or substrate settlement, deflection, movement, vibration, or displacement. i. The accumulation of moisture from condensation in or below the roof system. j. Exposure to extreme temperatures or humidity, for example, from equipment, exhaust, steam, hot water, freezers, or cold storage. k. Plants, animals, insects, or other living organisms. I. Incompatible materials or substances. m. Deliberate or negligent acts such as excessive traffic, rooftop storage, vandalism, misuse, or abuse. n. Falling, flying, dropped, discharged or blown materials, objects or debris. o. Change in building occupancy or rooftop usage. p. Unauthorized or improper repairs or modifications to the roof system. 9. The Warranty becomes a binding contract once it has been signed by both parties and all fees and expenses associated with the roofing project have been paid in full. 10. Temporary, emergency repairs to stop a leak may be made at Owner expense and will not void the Warranty, however it is Owner's responsibility to pay the cost of removing any excessive repairs. Promptly after making emergency repairs, Owner is responsible for following the Warranty Claim Procedure (see Form 900). 11. SOPREMA's failure to exercise or enforce any of its rights or powers under this Warranty is not a waiver and does not preclude SOPREMA from exercising any right or power in the future. Owner's failure to comply with any of the provisions of this Warranty applicable to it relieves SOPREMA of its obligations under this Warranty. 12. This Warranty is governed by and shall be construed and enforced in accordance with the intemal laws of Ohio, without giving effect to any choice of law rules that may require the application of the laws of another jurisdiction. Any lawsuit by Owner that is related to the Warranty, or the alleged breach of the Warranty, must be filed in the Medina County, Ohio Court of Common Pleas or the U.S. District Court for the Northern District of Ohio. Owner irrevocably consents to the jurisdiction and venue of these courts. 13. In order for Owner to bring a lawsuit against SOPREMA, Owner must, as a condition precedent thereto: (a) have complied with all of the terms and conditions of the Warranty applicable to it, and (b) the lawsuit must be commenced within one (1) year after the cause of action accrues. Time is of the essence. The failure to satisfy either of these conditions precedent shall result in Owner's claims being forever barred. 14. The terms of the Warranty are severable so that any illegal, invalid or unenforceable provision, if feasible, shall be modified so that it becomes legal, valid and enforceable, or if not so feasible, stricken, in either case without affecting the validity or enforceability of the remaining provisions. 15. This Warranty document (and the documents referred to herein) sets forth the entire agreement between SOPREMA and Owner with respect to the roof system. SOPREMA disclaims, and Owner waives, any affirmation of fact or promise that may have been made by SOPREMA or any of its employees, agents, representatives, or distributors that is not expressly stated in this Warranty. 16. The damages limited by the terms of the Warranty include, but are not limited to, loss or reduction of profits, interruption of business, injury to or illness or death of people or animals, damage or loss caused by or attributable to indoor air quality (including, but not limited to, the presence or growth of mold, mildew or other similar substance in, on or about the roofing system), or damage to or destruction of property, including the building or any of its contents, even if SOPREMA has been advised of the possibility, or even the likelihood, of any of these types of damages. 17. This Warranty may be transferred to a subsequent building owner upon compliance with the following requirements: (a) a transfer request is made in writing to SOPREMA's Warranty Department, (b) at the time the request is made, you pay SOPREMA its then current transfer fee, and (c) you make any repairs to the roof system or other roof or building components that are identified by SOPREMA after an site visit as being necessary to preserve the integrity of the roof system. For Questions Contact: SOPREMA, Inc. Warranty Department 310 Quadrat Drive Wadsworth, OH 44281-9571 Phone: (800) 356-5521 www.soprema.us (Form 101) (07/2013) Roofing Guarante Whereas WAYNE'S ROOFING, INCORPORATED, of Sumner, herein called "the Contractor," has completed application of the following roof Owner: SAMPLE WARRANTY Address of Owner: Type and Name of Building: Location Area of Roof Date of Completion: Date Guarantee Expires: Whereas, at the inception of such work the Contracto materials or workmanship for a limited period and subject to the c period of Two_( 2___) year from the date of completion made such repairs to said roof and composition flashin applied by or through the Contractor as may be necess' This guarantee is made subject to the following condit 1. Specifically excluded from this guarantee is any ana omissions of other trades or contractors; li ' Ming, wi foundation settlement; failure or cracking roof is applied, faulty construction of building; vapor condensation beneath the of the foregoing this guarantee shall there damage is repaired by the Contractor at the e 2. The Contractor is not liable for consequential composition flashing. 3. No work shall be done on said roof, including, b braces, railing, platforms -. uipment fastened roof, unless the Contra' • fied, shall recommendations wit render this guarantee n recommendations or repairs o 4. This guarantee shall become null such use was originally specified an covered by his guarantee. 5. This gu. st be or become effe accord. . uant to which 6. This gu. workmans 7. This guarant. 8. Additional co In Witness Whereof, rovid ieu of al or e es, subje oof, it will, a ing solely fro intain said ro of deck; copings, s for pitc' and void questing s to . or conten ut lim on the en the op o gua et forth: oresaid rnst faulty conditions h, that during a n cost and exp • ake or cause to be or defects in mate als or workmanship ertight condition. the building or contents caused by the acts or , or other unusual; phenomena of the elements; ure of material used as a roof base over which the lights, vents, supports, or other parts of the e. If the roof is damaged by reason of any ce of the guarantee period unless such trs. resulting from any defects in said roof or in connection with flues, vents, drains, sign d no repairs or alterations shall be made to said rtunity to make the necessary roofing application s are complied with. Failure to observe this condition shall be paid for time and material expended in making d roof. he roof is us , promenade or work deck or is sprayed or flooded, unless ation is noted in paragraph 8 below. Areas that pond water shall not be and until the Contractor has been paid in full for said roof in f was applied. ess th ontractor is promptly notified of the alleged defect in materials or he roof. arranties, express or implied s: as been duly executed this day of , 200X WAYNE'S ROOFING, INC. 13105 HOUSTON ROAD WASHINGTON 9)3390 AUTHORIZED REPRESENTATIVE Donald Guthrie, President PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0195 DATE: 06/20/2014 PROJECT NAME: INTERURBAN PUMP STATION SITE ADDRESS: 13980 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Atot ■ n Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 06/24/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/22/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WAYNE'S ROOFING INC Page 1 of 4 4:1:0 Washington State Department of Labor & Industries WAYNE'S ROOFING INC Owner or tradesperson GUTHRIE, DONALD D Principals GUTHRIE, DONALD D, PRESIDENT WETHERBEE, RODNEY ALLEN, VICE PRESIDENT WETHERBEE, KITTY, SECRETARY WETHERBEE, WAYNE W, PRESIDENT (End: 04/30/2007) MANN, SHARON R, SECRETARY (End: 04/30/2007) Doing business as WAYNE'S ROOFING INC WA UBI No. 600 178 144 13105 HOUSTON RD SUMNER, WA 98390 253-863-4455 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. WAYNESR205Q5 Effective — expiration 11/25/1980— 05/02/2015 Bond THE HANOVER INS CO Bond account no. 1968027 $12,000.00 Received by L&I Effective date 04/11/2011 04/13/2011 Expiration date Until Canceled Bond history Insurance https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600178144&LIC=WAYNESR205Q5&SAW= 07/08/2014