Loading...
HomeMy WebLinkAboutPermit D14-0197 - FATIGUE TECHNOLOGY - STORAGE RACKSFATIGUE TECHNOLOGY 401 ANDOVER PARK E D14-0197 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0223400050 401 ANDOVER PARK E FATIGUE TECHNOLOGY DEVELOPMENT PERMIT Permit Number: D14-0197 Issue Date: 8/7/2014 Permit Expires On: 2/3/2015 Owner: Name: Address: Contact Person: Name: GIBSON PROPERTIES LLC PO BOX 50268 , BELLEVUE, WA, 98015 MIKE SORENSON Address: 1100 SW 7TH ST, RENTON, WA, 98057 Contractor: Name: NORTH WEST HANDLING SYSTEMS IN Address: 1100 S.W. 7TH STEET, RENTON, WA, 98055 License No: NORTHWH275JF Lender: Name: N/A ( $5,000 Address: ,,, Phone: (206) 818-4488 Phone: (206) 255-0500 Expiration Date: 10/9/2015 DESCRIPTION OF WORK: INSTALLATION OF NEW AND USED RACKING FOR STORAGE OF BUSINESS RECORDS,. RECORDS STORED IN BANKER BOXES ON WOOD PALLETS DIRECTLY ON RACKS. PLEASE SEE ATTACHED DRAWINGS , ENGINEERING & SUPPLEMENT FOR DIMENSIONS, LOCATIONS, BUILDING INFORMATION & COMMODITY INFORMATION. Project Valuation: $2,800.00 Fees Collected: $257.98 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIIB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature_ Date: / �� l I hearby certify that I have read an exa fined this permit and know the same to be true and correct. All provisions of law and ordinances go erni g this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: b,Y Print Name: � (A C - dGrev�Sc �-� This This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 2: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Maintain fire extinguisher coverage throughout. 6: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 5: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 9: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 10: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 4: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 11: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 13: ***BUILDING PERMIT CONDITIONS*** 14: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 15: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 16: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 17: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 18: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. ; 1)114— Q l t 7 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: 4CA Ar►o,(9v'-ef Park • T Tenant Name: FA,17'1�Gt - reC.4le` d/09'f .L 1 c. PROPERTY(( OWNER yy., Name:/^ 4 yV- T2di/tn(09y ..t tC• Address:401 / 2 � Po,, lf6. City:✓ kw + /ffA-�0State:/4 Zip: Q Qs/$g CONTACT PERSON - person receiving all project communication Name: MI- Srev►sU,, Address: 10 0 SJ 7 c 7-- City: Q..sv/ r, State: V, Zip:Fos-7 Phone: t).o[ - eg. 4fl/ 1q Fax: G as-d-61 % Email: Vh St, (`eel SOr C? ✓) w k S • Corm GENERAL CONTRACTOR INFORMATION 7� Company Name/Uri/(e.STF4,it fy,i Ci.1I Address:l10v fw -7 g5 ...(-7 City: State: (d Zip?iOS 7 Phone: if - 'r 0. Fax l7 a , 76 Contr Reg No.:A �144, jse�, F Exp Datey q/(s 1No.: Tukwila Business License 3U C .. 09930 u 7 King Co Assessor's Tax No.: d a 3 `f 0 6d Suite Number: / Floor: / New Tenant: ❑ Yes l Ro IiTECT OF RECORD Comp Name: Architect Name: Address: City: State: Zip: Phone: Fax: E il: ENGINEER OF RECORD Company Name: " a P y P i f !9 04r� C4;1222 r# Engineer Name: ✓✓ Gam y ! G..7 Address: if' �j _ a /�.p.7scee c //�� ��Sttaate: City: ( 42 �'lvici ( c A Zip?1 q Phone-s( CC1 .j Fax:G�/ _i)s ej'D25 ' ? Q Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: cti_rh Address: / pit-c`t `'Zip: H:Wpplications\Forns-Applications On Line:2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 1 of 4 Valuation of Project (contractor's bid price): $ / a `/O Existing Building Valuation: $ g Ae e Addition to Existing Structure Type of Occupancy per IBC Attached Carport Covered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact Handicap: Will there be a change in use? ❑ Yes �No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: L—v1/ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes/No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Describe the scope of work (please provide detailed information): y,, f, GI(Ln ®r /�,Q,�;,,/ gn� c'. a e' GUet 4c. Sites a-r Jjl.�s i/-S.i recvrSl - d r-r -�' ,.ed ,.-, 64.4621' bow Op, c C(t s 61 cji oft (-adz,- `'(.ramlc Lee 4 414 dr- 1 t tt i- sly (.Q v,.,t-:// ,( of t ettA 1 C.^f/ /e ca 5, bcc l 6: /ite in. grifiA./T Gr tr.' CO Al /ri (4.1 ArC) ;. • Will there be new rack storage? Yes ❑.. No If yes, a separate permit and plan submittal will be required. H:\Applications\For ms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 TIiN lO'TES— Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI ENT: Signature: v Date: Print Name: 0( e- c &'ZX&✓I Day Telephone: e?e, c C Cf 4cS Mailing Address: it 60 $ 7 .S/ I e0 ,4 /1 `-/4- % f'O 7 City State Zip H:Wpplications\Fomu-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT ( QUANTITY PermitTRAK I PAID $16106 D14-0197 Address: 401 ANDOVER PARK E Apn: 0223400050 $161.06 DEVELOPMENT $153.60 PERMIT FEE R000.322.100.00.00 0.00 $149.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $7.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2801 R000.322.900.04.00 0.00 $7.46 $161.06 Date Paid: Thursday, August 07, 2014 Paid By: MICHAELJ SORENSON Pay Method: CREDIT CARD 025212 Printed: Thursday, August 07, 2014 9:53 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $96.92 $96.92 $96.92 $96.92 $96.92 D14-0197 Address: 401 ANDOVER PARK E Apn: 0223400050 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2448 R000.345.830.00.00 0.00 Date Paid: Monday, June 23, 2014 Paid By: MICHAEL SORENSON Pay Method: CREDIT CARD 005117 Printed: Monday, June 23, 2014 4:01 PM 1 of 1 INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Prof 1- 1---A-T. �F_ ec, Type of Inspection:, E,./1(Ai/\ FA» L Addres .• 4 d POD oJf--r se, Date Called: Special nstructions: /�- _ e.-. tP—> 'bate Wanted: — 1 a.m. p.m. Requester: Phone No: Approved per applicable codes. EJCorrections required prior to approval. COMMENTS: Inspe or: Date: w REINSPECTION FEE RE UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER INg--et` T PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 - 206-575-4407 Project: Qj tti,,Q r-b 164)1 Type of Inspection: IAcc.- V-- Address: V Suite #: c..(01 Pc i?1 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. COMMENTS: -(L L.s-d --, -'L-- nCorrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: rms 3 Date: ef 31, `f Hrs.: I- p n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 FILE COPY Permit No. NORTHWEST HANDLING SYSTEMS, I N C. e Materla Han, ing Experts 1100 SW 7th St Renton, WA 98055 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 401 Andover Park E. TENANT NAME: Fatigue Technology Inc. DATE: June 23, 2014 APPLICANT: Mike Sorenson / (206) 818-4488 1. Load application and rack configuration drawings attached. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 5 2014 City of Tukwila BUILDING DIVISION 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored in racks: Paper business records in banker boxes on wood pallets directly on pallet racks. 6. Sprinkler System Information: .60 GPM / 2500 square feet. Sprinkler head temperature: 165 degrees. 7. Smoke and heat vents are in place. 8. Building exits indicated on attached drawings. b1'1o1q7 RECEIVED CITY OF TUKWILA JUN 21 2014 PERMIT CENTER BY. G. OHANIAN DATE.6-16-14 SUBJECT RAdK DENI(N & EN(INEERINd do. 412 WEBT BROADWAY, BUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 JOB NO.. RD-17394 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: FATIGUE TECHNOLOGY, 401 ANDOVER PARK EAST TUKWILA, WA 98188 PER IBC 2012 EDITION STORAGE RACKS CAPACITY: 2250 # / LEVEL AT TYPE "A" 1500 # / LEVEL AT TYPE "B" CALCS. 1 THRU 4 DRAWINGS: RD-17394 FILE COPY ' "c • Permit No. EXPIRES 12-26-15 bI'oI7 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 05 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 2.3 2014 PERMIT CENTER (o r V BY G. OHANIAN DATE 6-16-14 SUBJECT RAdK DEOI(N & EN(INEERIN( do. 412 WEBT BROADWAY, ONE #204 dLENDALE, dA. 91204 TE14818)240-3810 FAX:(818)240-3813 SHEET NO. 2 JOB NO.. RD-17394 144" 6" BEAM f $ TYPE "A" 144" LONG BEAM Ix=4.42 Sx=1.44 Fy =55 KSI' 96" LONG BEAM 0 SEISMIC DESIGN _ SXIps V— Rx1.4 xW Ix=1.63 Sx =.77 Fy =55 Ksl. 96" 1 4" BEAM 1 1 TYPE "B" 4 LOAD PER BEAM + 25% IMPACT LOAD (2.2KX.88)+(1.1 KX.25) = 2.3— 1.1 K �BEA►1S M= 8 = 20 "K S R= .62<1.44 A= 5xwL4 " 384.1x.E =•34 <180 = 80 LOAD PER BEAM + 25% IMPACT LOAD (1.5 Kx.88)+(.75 Kx.25) = 1.5 = .75 K 2 BEAMS M= 82 =9.0K S R= .27<.77 4 A 384WL =.18"< 180 =.53" xE IBC 2012 AND RMI SPECS. S Ds =0.96 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED W=D.L.+ 3 PALLET LOAD LOAD PER COL. = 2x2.2 K —2.2 K 2 coy. P=.2DC (2.2Kx0.75)=1.9K W=.2DCE (2.2, x0.67)= 1.7 K \L= '20 K ONGIT. V = .29K TRANS. LONGIT. SEISMIC 44" 1 } SIDE VIEW 13K 07K 3.7-K 3.7 K 11.6 "K .20K 0 By G. OHANIAN DATE .6-16-14 SUBJECT RAdK DESI(NN & EN(4INEERIN(4 d0. 412 WE BROADWAY, PUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 3 JOB NO.. RD-17394 COLUMN ANALYSIS ,1 x- 3" —.— x t=.070" J Fy=55 KSI Ae=.62 1x=.95 S e=.6 rx=1.2 ry=1.1 KL=60x1.7 _85 rx 1.2 r _ T=47 Y • Mn=Se.Fy=35 COMBINED STRESS RATIO Oc.P Ob.CM _ Pex= (2 =27.0 Oc=1.8 P� + mx.M�.ax —.72<1 Ob=1.67 aX=1— Pex .87 Cmx=.85 BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .20 K (1)-1/2"0 ANCHOR PER BASE PL., 3 1/4" EMB. HILTI KWIK BOLT—TZ ESR-1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.07x1 x65=2.3 K BEARING CAPACITY OF COL. HOLE 7/16"0 RIVET A= .1 Fy=79KSI Pa = .1x79x.4 = 3 K Ma = (2.3 Kx4")+(1.1 Kx2") =11.4"K 3 PIN CONN. CONN. MEND= .01 xwl 2= 1.6 "K M _ 7.7"K M= 9.3"K SEISMIC TOTAL Fe=(j =40 rx 2 F n=F y(.658 A c )=31 KSI Pn=Fn.Ae = 19.0K 1.9K A c = Fy /Fe = 1.17 Ac<1.5 3"x4 1/2"x1/8" BASE PLATE io 3" BY G. OHANIAN DATE.6-16-14 SUBJECT RAdK DESIGN & ENC4INEERINCI do. 412 11E BROADWAY, �UITE #204 LENDALE, CA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 4 JOB NO.. RD-17394 OVERTURNING =.29Kx x146"x0.66 =56"K MOT COL MR = 1.9 Kx44"= 83"K NO UPLIFT LOAD TO DIAGONAL P = .29 Kx2 coxL _ .76 K FY =55 KSI Ae=.29 rx =.46 L= 58" Po = 2.5 K CHECK WELDS pn= (1_ .01L)L.t.F„ = 4.4K f2= 2.55 P�=1.7KX2 —3.4K SIDES CHECK SLAB 1900 --1.9 01 1000 29K 1.9x 144=273 °" =17" M= (12 )x1000x 2 x12=666 "# 5= ,2r2.72 666 = 9 < 1.6 2500 =80 72 1.9 K 1.9K 1L/X 711 j N 29 K a 0 N 44" TOP LEVEL LOADING W= 0.2DL+1.111=1.3K LOAD PER COL. V= .23 K MOT = .23 Kx x 120" = 55 K COMR = 1.3 Kx44" = 59"K NO UPLIFT BOTH SIDES TYP 1/8 "1.5" 1 1/2" t=.06" TYP 1 1900# 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL City of Tukwila Department of Community Development July 09, 2014 Mike Sorenson 1100 SW 7th Street Renton, WA 98057 RE: Correction Letter # 1 Permit Application Number D14-0197 Fatigue Technology - 401 Andover Pk E Dear Mike Sorenson, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Dave Larson at 206-431-3678 if you have questions regarding these comments. The plans show two sections of racking in the new area that are 36 inches wide. The engineering calculations and details do not include these narrower rack sections. Please revise plans and calculations to include this third rack configuration. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, WdiLJJ enni r sh ermi T nici File o. D14-0197 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 NORTHWEST HANDLING SYSTEMS, I N C. e Materia Handling Experts 1100 SW 7th St Renton, WA 98055 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 401 Andover Park E. TENANT NAME: Fatigue Technology Inc. DATE: June 23, 2014 APPLICANT: Mike Sorenson / (206) 818-4488 1. Load application and rack configuration drawings attached. 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored in racks: Paper business records in banker boxes on wood pallets directly on pallet racks. 6. Sprinkler System Information: .60 GPM / 2500 square feet. Sprinkler head temperature: 165 degrees. 7. Smoke and heat vents are in place. 8. Building exits indicated on attached drawings. bt'+oIq7 RECEIVED CITY OF TUKWILA JUN 21 2014 PERMIT CENTER PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0197 DATE: 07/29/14 PROJECT NAME: FATIGUE TECHNOLOGY SITE ADDRESS: 401 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Aux Building Division Public Works Fire Prevention Structural El Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 07/31/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 08/28/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0197 DATE: 06/23/14 PROJECT NAME: FATIGUE TECHNOLOGY INC SITE ADDRESS: 401 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Cpr- Building Division Public Works C O1.01i9 ire Prevention Structural ❑ Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/24/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 111 Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/22/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov RECEIVED BY JUL 112014 NWT Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D 14-0197 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Fatigue Technology Project Address: 401 Andover Park E Contact Person: MtKam. Phone Number: 2-06 " 8( vi(S" Summary of Revision: �// rer- a,RISkSSic'- t, iI v 0� Lars-6/1 a#aC dr&v,"i J d i `C4 - 2 e n d d ,,S 4 36 d -ezf 1^a_ ckS Qs S . MEWED CITY OFTUKWI A Jul 2 9 2014 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revjfion Received at the City of Tukwila Permit Center by: �t�( J Entered in TRAKiT on C:\Users\jennifer-m\Desktop\Revision Submittal Form.doe Revised: May 2011 NORTH WEST HANDLING SYS T"` Page 1 of 2 45 Washington State Department of Labor & Industries NORTH WEST HANDLING SYS INC Owner or tradesperson FRANCK, JAMES JEROME Principals FRANCK, JAMES JEROME, PRESIDENT KOSTY, CLARK RANDOLPH, TREASURER THOMAS, KEVIN A (End: 09/28/2011) Doing business as NORTH WEST HANDLING SYS INC WA UBI No. 600 051 641 1100 SW 7TH ST RENTON, WA98055-2939 425-255-0500 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. NORTHWH275JF Effective — expiration 04/06/1973-10/09/2015 Bond TRAVS Bond account no. 81 S103354822BCM Received by L&I 10/09/2001 Insurance Travelers Indemnity Co of Ame Policy no. 6302C242044T1A13 Received by L&I 10/03/2013 $12,000.00 Effective date 10/01/2001 Expiration date Until Canceled $1,000,000.00 Effective date 10/01/2013 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641 &LIC=NORTHWH275JF&SAW= 08/07/2014 TYPE"M" TYPE "C 44X98 12' 44X120 44X120 WAR 44X106 144X54i SE TYPE "N" 448F144. TYPE B" 44XYP120 44X120 EXIT 6.3 1/2" TYPE "R" 38X144 TYPE "R" 30044 TYPE "R" 310044 TYPE "G" 38X144 TYPE "G" 36X144 TYPE "G" 38X144 TYPE "R" 381f144 TYPE "G" ' 3614144 TYPE "G" 38X144 TYPE "G" 36X144 44X120 RAGE 44X120 TYPE "B" 44X120 TYPE "B" 44X120 44X120 TYPE "C" 44X98 TYPE "B" 44X120 TYPE "B" 44X120 PE'B" 44X120 WAREHOUSE 44X96 30'x60. PACK STATION GRAVITY CONY. 44X96 12'-0 9/16 WAREHOUSE 12'-1 1/2• 44X96 AREHOUSE LAB TEST HALL 132 TEST LAB .L D 8 AIAIA DEMO 108 DISPLAY 106 CONF 174 RECEPT 103 V PLAN VIEW SCALE: 1/16" = 1'-0" HALL LUNCH SEPARATE PERMIT REQUIRED FOR: ®"Mechanical IrtIectrical goriumbing ailGas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of ukwila Building Division. VOTE: r vis;ons will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. t1M 0 to Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and co itions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION CORRECTION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 5 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 2 9 2014 PERMIT CENTER PROJECT TITLE SHEET NUMBER ANDOVER PAR TU K WI LA, WA 98188 DRAWING NUMBER ANCHOR clock TYP SEC. A -A TYP BOLT PER BASE PLATE EMB., (SEE NOTE NO. 4) SEC. B-B 7/16'0 RIVET ASTM A576-9013 HOT —WROUGHT UNS G10100 GRADE C-1010 t=3/16 BASE PLATE DETAIL BRACING DETAIL PIN CONNECTION Om GENERAL CONFIGURATION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 5 2014 City of Tukwila (BUILDING DIVISION NOTES; 1—DESIGN OF STEEL STORAGE RACKS AND CALCULATIONS ARE IN COMPLIANCE OF THE INTERNATIONAL BUILDING 2—STEEL FOR ALL SHAPES FY=55 3—NO FIELD WELDING IN THIS PROJECT OF THE APPROVED FABRICATOR 4—ALL ANCHORS HILTI KWIK BOLT—TZ SPECIAL INSPECTION IS REQUIRED 5—CONCRETE SLAB 6" THICK 2500 6-STORAGE RACK CAPACITY 2250 1500 #/ LEVEL AT TYPE "B" 7—RACK INSTALLATIONS SHALL DISPLAY A PERMANENT SIGN OF 50 SQUARE OF THE RACK (SEE NOTE NO. 8—STORAGE RACKS SHALL BE INSTALLED VERTICAL OF 1/2" IN 10'-0" 9—THE CLEAR SPACE BELOW SPRINKLERS BETWEEN THE TOP OF THE STORAGE 10—STORAGE RACK AREA NOT OPEN 11_11m_p It) 0CI AS SHOWN BY THESE DRAWINGS WITH THE REQUIREMENTS CODE 2012 EDITION AND RMI SPECIFICATIONS KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED) ALL WELDED CONSTRUCTION IN THE SHOP #00777 (E70XX ELECTRODES) ESR-1917 PSI. SOIL BEARING CAPACITY 1000 PSF #/ LEVEL AT TYPE "A" IN ONE OR MORE CONSPICUOUS LOCATIONS INCHES IN AREA, SHOWING THE CAPACITY 6) WITH A MAXIMUM TOLERANCE FROM THE OF HEIGHT SHALL BE A MINIMUM OF 18 INCHES AND THE CEILING SPRINKLER DEFLECTOR. TO PUBLIC, EMPLOYEE ACCESS ONLY RECEIVED CITY OF TUKWILA JUN 213 2014 PERMIT CENTER 6" BEAM 4" BEAM RACK DESIGN AND ENGINEERING 412 WEST BROADWAYF SUITE #204j GLENDALE, CA. 91204 SCALE: NONE DRAWN BY: . 44 6l DATE: 6-16-14 99662 PROJECT: FATIGUE TECHNOLOGY, INC. 401 ANDOVER PARK EAST, TUKWILA, WA 98188 TYPE !! A!! TYPE B SIDE VIEW `' - STORAGE RACK DETAILS JOB NO. RD-17394 SHEET NO. EXPIRES 12-26-15