Loading...
HomeMy WebLinkAboutPermit D14-0206 - JOE WAGNER - PARTITION WALLSJOE WAGNER 631 S'IlRANDER BLVD STE C D14-0206 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0223300020 Permit Number: D14-0206 631 STRANDER BLVD Suite C Project Name: JOE WAGNER Issue Date: 7/21/2014 Permit Expires On: 1/17/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: CWWATUKWILA 1 LLC PO BOX A-3879 C/0 EQUITY OFFICE MGMT LLC, CHICAGO, WA, 60690 DAVID KEHLE 1913 BONAIR DR SW , SEATTLE, WA, 98116 ALEXEEV CONSTRUCTION Phone: (206) 433-8997 Phone: (253) 230-4788 Address: PO BOX 731152 , PUYALLUP, WA, 98373 License No: ALEXECS934P9 Expiration Date: 10/29/2015 Lender: Name: SELF FUNDED -JOE WAGNER Address: Ill DESCRIPTION OF WORK: REMOVE PORTION OF AN EXISTING NON -BEARING WALL, CONSTRUCT NEW NON-BERAING OFFICE PARTITION FOR OFFICES PER PLAN Project Valuation: $12,000.00 Fees Collected: $557.86 Type of Fire Protection: Sprinklers: Fire Alarm: YES Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: I hearby certify that I have read and provisions of law and ordinances gov xami ning Date: d this permit and know the same to be true and correct. All his work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating co truction or the performance of work. I am authorized to sign and obtain this development permit and agree tij condi' attached to this permit. M Signature: _:!A� r' Print Name: inLNI • J. Date: O ` ,o 01( This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 30: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or Tess. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unlless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 24: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 25: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72-17.5.3.1) 27: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 28: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 26: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. D 0)-0 Project No. Date Application Accepted: 1 `)--( { Date Application Expires: 1. (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: � �-�//�1� z No - Dar) , Tenant Name: y1fDal-_ PROPERTY OWNER Name: hppa2 L1 EW Address: 31 Otathes 50/2 ail a City: Su 66 State Zip.Qm CONTACT PERSON — person receiving all !Reject communication /�( ,,u ,", Name: c& o be�1Z, Lill rteet. Address: W rjowe pv oy City:jfW State:: , Zip iko Phonetr_/4503 _q, q fl Fax:Ao . t4,6, i Email: ei`elik Co eihellea,lcA4.0144 GENERAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:UpplteationslForn -Applications On Line 12011 Applications\Permit Application Revised - 8-9-11.doc Revised: August 2011 bh King Co Assessor's Tax No.: L Mi04 "I O (5 - D� Suite Number: G Floor: ( New Tenant: El Yes 10..No ARCHITECT OF RECORD Company Name: Woj/i ix' f v.„. tirec Architect Name: (7�1° if�� Ybrya Address: II 'r„ Y� W ��tel 0y State Val 1 Zi1104 ) City !ii`" Phone:/*.43,1b4" Fax:4Q/l r _., _d Email: f.N1e',te @ AD'w.hie4YG:1a cem4 ENGINEER OF RECORD Company Name: Igise Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 1 , - _ . _' '- 1 1, Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ 1.1 14 ILLk)-1 Describe the scope of work (please provide detailed information): PelobiE geiTca,I J.N W55fl+ 1•4i-ealli►-i4 V31-6i i c-t NAY 1,64- -11, orou pinmcf4 cfrict- F14641 Will there be new rack storage? ❑ Yes I . No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to New Type of Construction per IBC Type of Occupancy per IBC Existing Structure 1' Floor 1 1 e el, vI, E5 0CV 2ed Floor 3td Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Wit Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: lib 644.14E t rkk11XICompact: Handicap: Will there be a change in use? 0 Yes 121 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `;yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safe ata Sheets. SEPTIC SYSTEM r�NC 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:UpplicationsTorma-Applications On LineVA11 Applications \Permit Application Revised - 8-9-11.doac Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AM) I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER tom'. ' AGENT: Signature: Print Name: ribti 0 hEti� Mailing Address: MI N,tQ H:Upphcations\Forms-Applications On Line\2011 Apphcuions\Permit Application Revised - 8-9-11.docc Revised: August 2011 bh Date: 01lb 2 Day Telephone: vb, II I tP City State Zip Page 4 of 4 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID $346.28 D14-0206 Add 1 STRANDER BLVD Suite C Apn: 0223300020 $346.28 DEVELOPMENT $330.00 PERMIT FEE R000.322.100.00.00 0.00 $325.50 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $16.28 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2633 R000.322.900.04.00 0.00 $16.28 $346.28 Date Paid: Monday, July 21, 2014 Paid By: A C S LLC Pay Method: CREDIT CARD 021383 Printed: Monday, July 21, 2014 7:48 AM 1 of 1 SYSTEMS DESCRIPTIONS ACCOUNT I QUANTITY PAID PermitTRAK $211.58 D14-0206 Address:63 STRANDER BLVD A Apn: 0223300020 $211.58 DEVELOPMENT $211.58 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2523 R000.345.830.00.00 0.00 $211.58 $211.58 Date Paid: Wednesday, July 02, 2014 Paid By: DAVID KEHLE Pay Method: CREDIT CARD 025399 Printed: Wednesday, July 02, 2014 2:23 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPE N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 - (206) 431-3670 Permit Inspection Request Line (206) 431-2451 prof ' A Type of Ins ction; -- / 147 i 1 Add to Calla Specs flnstructions: baterte : ..r ,� a.m. p.m. Requester: Phone No: ved per applicable codes. Corrections required prior to approval. COMMENTS: e2AL Tip"; �a. Inspector: Date: .(5 El REINS1�30 N FEE RE 9 T IRED. Prior to next inspection, fee must be paid at 0 Southcenter Blvd., Suite 100. Call to schedule reinspection. i INSPECTION RECORD tain a copy with permit P ' MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 1f100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 431-2451 Project,_: Project: wA& iv, Type of I coon: , Type AZ—. n6 Addres : 3 -iT7 t Date Called: Specia nstru tions: ! bate Wanted: l .'� .--1 era.to,. p.m. Requester: Phone No: 2 c3 -• 33 - 4243 � Approved per applicable codes. tJ Corrections required prior to approval. COMMENTS: or: Date: REINSPECTION Bi�8tJ1R�0: Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. u chgdule reinspection. INSPECTION RECORD Retain a copy with permit Di Ig2-N40 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 8100, Tukwila. WA 98188 (206) 431-3670 ti, Permit Inspection Request Line (206) 431-2451 Project �D'e »A lv Cie- Type inspection: .AA, . N, II d Address: 03t,A.e. Date Special Instructions: 5 U c f e ( / Date Wanted• 14 - aa._m Requester: Phone No: Approved per applicable codes. aCorrections required prior to approval. COMMENT& i)f AR LAskGl f a ins Date ✓2.4 REINSPECTION FEE REQUiED. Prior to next inspection, fee must be paid at 6300 Southcenter B1 . Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 NOW: ct: - --��-- //'' Ty of Inspection: Address: (� 3,,) sk r�{r - - Suite #: c Contact Person: Special Instructions: Phone No.: Approvedper applicable codes. COMMENTS: riCorrections required prior to approval: k Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: .--= Inspector:1 s"a Date: g'At/ " Hrs.: / n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: City: Word/Inspection Record Form.Doc Company Name: State: 6/11/10. ZU: T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: C(Ai wA . ,,,. l L.LC Type of Inspe 'on: F Address: Suite #: (S STraik.cuit 4 . G Contact Per on, Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: A-tta)9 /« /VIA -- %= zg u Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: inspector ,,$ 13 Date: I/z 0 Hrs.: 10 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: ddress: City: Word/Inspection Record Form.Doc State: 6/11/10 Zip: T.F.D. Form F.P. 113 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Envelope Summary ENV -SUM 2012 Washington State Energy Code Compliance Forms for Commercial. Group RI and > A atnry R2 & R3 Revised June 2013 Project Info Project Address u, Date (n`oLt.. W L117414,4tYL OWni DvCbato G For Building Department Use COPY Applicant Name: ati `i2 60..tic �P IA. ` 'w.r -. Applicant Address: Mite0146ta co4iy*1,��J� g14(r' Applicant Phone: / ,40¢ viol Project Description • New Building ❑ Addition Alteration ■ Change of Occupancy/Conditioning Compliance Path ❑ Prescriptive ❑ Component Performance ❑ Total Building Performance Occupancy Group dre Commercial 0 Group R (R-1 & > 3 story R-2 and R-3) Climate Zone 6 Climate Zone , < 9 0 Climate Zone ((( See WSEC 301.1 for county list) Vertical Fenestration and Skylight Area Calculation If complying via the Prescriptive path, provide values for vertical fenestration, skylights, gross walls end roof. If complying via the Component Performance path, these values are auto- filled by the ENV UA form and cannot be edited here. Total Vertical Gross Exterior Fenestration Above Grade % Vertical (rough opening) divided by Wall Area times 100 equals Fenestration 44 + X 100 = Gross Exterior Total Skylight divided by Roof Area times 100 equals % Skylight _ X 100 = Maximum Prescriptive Fenestration Area Vertical Fenestration IVA REVIEWED FOR CODE COMPLIANCE Skylights APPROVED 50% Floor Area in DLZ 0 More than 50% of the floor area in daylight zone per C442.3.1.1 JUL 11 2011 Semi -Heated Path ■ Project has semi -heated areas as defined per C402.1.4 ❑ Applying wall exception to semi -heated areas 1. To be deemed semi -heated the area is heated but not coo output -he betweencapacity 4 be Btuh/ft2.ro for n Refer to C402separately spacesseparately from separate compliance forms for each conditioned area type. 3.Semi-heated spaces may comply under the Prescriptive or path. 4.Envelope elements separating semi -heated from other conditioned thermal envelope requirements for an exterior wall. City Of Tukwila DING DIVISION requirements. other conditioned spaces —provide Component Performance compliance spaces shall comply with Refrigerated Spaces ■ Walk-in cooler 0 Walk-in freezer ❑ Refrigerated Warehouse Cooler 0 Change of Occupancy/Conditioning Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for these areas may be combined with non -refrigerated areas in the ENV -PRESCRIPTIVE for. Refer Mixed Occupancy and/or Space Conditioning Project includes more than one occupancy type and/or level of space conditioning. compliance forms may be required. Select all that apply to scope of project: 'Commercial ❑ Group R1 or >3 story R2/R3 ■ Refrigerated ■ Fully Conditioned 0 Semi -Heated ■ Low Energy' Group R2/R3 < 3 story R 'Low energy areas are exempt from all thermal envelope provi ptyd these areas are not required. Refer to C101.5.2 for exemption. �� �� YY Multiple Space n � j�p �/' 1. otti.,44v7 eth,via4 ENwl:pi) 111�rVr� JUL.0 2 2014 RMIT CENTER • 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary LGT-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address - - 'Date 010 fob di Pt12 e,*Vp, e- For Building Department Use Applicant Name: V esi tp �/„�,�j., c hzc', V f mG t Lwr 1 t c' Applicant Address: 2. j Applicant Phone: Project Description 4 Alteration ❑ New Building ■ Addition ■ Plans Included Lighting Compliance Path 0 Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option 0 Building Area Method QQ Space -by -space Method Interior Lighting System Description Briefly describe lighting system type and features. 10 64. pow to Vit6E Additions and Change of Space Use (C101.4.3 & C101.4.4) • Addition area or Change of Space Use area complies with all applicable area or Change of Space Use area is combined with existing with all applicable provisions Building Area Method (LTG-INT-BLD) or Space -By -Space and proposed (including existing if applicable) lighting wattage provisions as stand alone project building lighting systems to demonstrate Method (LTG-INT-SPACE) Compliance Form. Document maximum of Addition or Change of Use scope. Provide applicable lighting �• Addition compliance Provide allowed controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) E 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing) lighting wattage of project scope ❑ Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG-INT-SPACE) Compliance Fonn. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased ■ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific conb'ols (C405.2.3), and commissioning of lighting controls per C405.13 Provide applicable application ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. • Space is reconfigured - luminaires unchanged or moved only applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. Provide all o changes are being made to the interior lighting and space use not changed. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: "D 14-0206 PROJECT NAME: JOE WAGNER DATE: 07/02/14 SITE ADDRESS: 631 STRANDER BLVD - BUILDING A X Original Plan Submittal Response to Correction Letter#, Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Awc, 1--`1-01 Building Division II bk..k Ail+ lir tiA Public Works Fire Prevention in Structural OG Ai° 0/1.011,9 Planning Division 111, Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 07/03/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 07/31/14 Approved with Conditions TW Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: rash Center I se 0 CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 ALEXEEV CONSTRUCTION SVCc',LC Page 1 of 2 Washington State Department of Labor & Industries ALEXEEV CONSTRUCTION SVCS LLC Owner or tradesperson ALEXEEV, ALEXANDR A Principals ALEXEEV, ALEXANDR A, MANAGER ALYEKSYEYEV, OLEKSANDR, PARTNER/MEMBER (End: 10/14/2013) Doing business as ALEXEEV CONSTRUCTION SVCS LLC WA UBI No. 602 767 386 PO BOX 731152 PUYALLUP, WA 98373 253-230-4788 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ALEXECS934P9 Effective — expiration 10/29/2007-10/29/2015 Bond CBIC Bond account no. SF2145 Received by L&I 10/29/2007 Insurance Ohio Security Ins Co Policy no. BKS53146520 Received by L&I 10/30/2013 $12,000.00 Effective date 10/22/2007 Expiration date Until Canceled $1,000,000.00 Effective date 11/16/2013 Expiration date 0\`'l https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602767386&LIC=ALEXECS934P9&SAW= 07/21/2014 BUILDING 4 SITE BUILDING CODE: ZONING: SEISMIC ZONE: CONSTRUCTION TYPE: OCCUPANCY GROUPS: ALLOWABLE BUILDING AREA: UNLIMITED, 60' YARD ON ALL SIDES, AND FULLY SPRINKLERED NO CHANGES TO PARKING NO CHANGES TO EXTERIOR NO CHANGES TO BUILDING ENVELOPE AREA OF TENANT: 1,331 SF TENANT SPACE AREA OF REMODEL: 600 SF ESTIMATED COST: $ 12,000 TAX ID. # 252304-9015-04 LEGAL STATI5TIC5 IBC 2012 M-1 ZONE 3 V-15_ THAT PORTION OF THE SOUTHWEST QUARTER OF SECTION 25, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE EAST QUARTER CORNER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M.± THENCE NORTH SSD06'42" WEST ALONG THE EAST -WEST CENTERLINE OF SAID SECTION 26 A DISTANCE OF 105.54 FEET± THENCE SOUTH 01D41128" WEST 90.66 FEET± THENCE SOUTH SS012'32" EAST 233.00 FEET TO THE TRUE POINT OF BEGINNING± THENCE FROM THE TRUE POINT OF BEGINNING SOUTH SS1D12'32" EAST 291.50 FEET TO A POINT ON THE SOUTHWESTERLY MARGIN OF' JAMES CHRISTENSEN ROAD NO. 1479± THENCE ALONG SAID SOUTHWESTERLY MARGIN THE FOLLOWING 1 COURSES± SOUTH 321D39'25" WEST 96.43 FEET± SOUTH 20D16'25" WEST 114.09 FEET± SOUTH 03D06'25" WEST 122.13 FEET± SOUTH 02D41'35" EAST 95.54 FEET± SOUTH 191D53'35" EAST 168.86 FEET± SOUTH 32D2S135" EAST 15.524 FEET± SOUTH 44035'35" EAST 25.31 FEET± THENCE LEAVING SAID SOUTHWESTERLY MARGIN SOUTH 01D41'28" WEST 461.42 FEET± THENCE NORTH SSD12'32" EAST 254.00 FEET± THENCE NORTH 01D41'28" EAST 18.00 FEET TO A POINT ON THE NORTHERLY MARGIN OF MINKLER BOULEVARD± THENCE ALONG SAID MARGIN NORTH 5E012'32" WEST 103.00 FEET TO A POINT ON THE CENTERLINE OF A PRIVATE DRIVE± THENCE ALONG SAID CENTERLINE NORTH 01D41'28" EAST TO A POINT OF CURVATURE ± THENCE TANGENT TO THE PRECEDING COURSE ALONG THE ARC OF A CURVE TO THE LEFT, A DISTANCE OF 11.18 FEET, HAVING A RADIUS OF 250.00 FEET AND A CENTRAL ANGLE OF 11D49'33" TO A POINT OF REVERSE CURVATURE± THENCE FROM A TNAGENT WHICH BEARS NORTH 161D02'05" WEST ALONG THE ARC OF A CURVE TO THE RIGHT, A DISTANCE OF 11.15 FEET, HAVING A RADIUS OF 250.00 FEET AND A CENTRAL ANGLE OF 111D49'33" TO A POINT OF TANGENCY ± THENCE TANGENT TO THE PRECEDING CURVE NORTH 01D41'28" EAST 511.11 FEET TO THE TRUE POINT OF BEGINNING. SEPARATE PERMITS: PLUMBING 14VAC MODIFICATIONS ELECTRICAL SPRINKLER MODIFICATIONS t. COVERALL FLOOR PLAN: NORTH NO SCALE 1929-ZZ9 696Z-SSZ 099T-BE6 Tr6 I T8 sop 1Dln2DN uogiulysDM rasod 3a8nd (uwo1S/Ja;vM) sxJoM 311gnd o1101301L Jo tc310 (41110 43ua8raw3) Dilm301L JD 4313. Muo (CouaBJauig) aal1od D11lo1►1L Jo Kim SWITIMIN 31NONd .IDN80t(31Wa TUKWILA COMMERCE CENTER ranto,L 8u11oo3 9u111ra carols JJO ;me 'P ralaFy uo11o81r.4 wool(1Dolrloai; u1DW 8u1P11n9 JJo cults'rama , so9 IJO 4ni5'p *maw raioht vERALL SITE PLAN: 0 • • • 0 SEPARATE PERMIT REQUIRED FOR: CirMechanical Iectrjcal ei''lumbing erbas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: vision will require a new plan submittal and may include additional plan review fees. PLANNING APPROVED • No changes can be these plans without approval from DCD Planning Division of Approved By:S..�.l..a� r-.— Date: REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 1 2014 AT. 144 City of Tukwila BUILDING DIVISION FILE COPY Permit No. ►► �-i ~ 12..O( Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any ado'�y : d • 4 • r ordi � «a�; Receipt of approved Field Copy «««._ , s is acknowledged: Ey: Date: Miff City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA 0225 GVA 1 w 0 a m 06 -30-14 DESCRIPTION a • (0(0 00. N N CITA U IMPROVEMENT FOR: JOE WAGNER A PROPOSED TENANT LA COMMERCE CENTER ra:) fc4 Iz -i=d• 0 SCOPE OF WORK REMOVE PORTION OF AN EXISTING NON BEARING WALL, CONSTRUCT NEW NON —BEARING OFFICE PARTIONS FOR OFFICES, PER PLAN NORTH NO SCALE JUL .022014 PERMIT CENTER 29'-8" EXISTING OPEN OFFICE RELOCATE EXISTING T-STAT REMOVE EXISTING WALL, ODOR AND WINDOW PATCH AS REQUIRED. EXISTING OFFICE P{ EXISTING OFFICE vami NORTH FLOOR PLAN: EMO SCALE: 1/8" - I'-0" DEMO NOTES: 1. REMOVE EXISTING WALL, DOOR AND WINDOW A5 SNOUrN. 2. PATCH AND REPAIR EX. WALLS, FLLOR AND CEILING AS REQUIRED. 3. REMOVE EXISTING POWER AND PULL UP TO A NEW J-BOX LABELED WITH CIRCUIT AND PANEL 4. REMOVE EXISTING UNUSED CABEILING FOR PHONE AND DATA. 2x4 WOOD STUD WALL (SEE SCHEDULE) 2x WOOD BLOCKING 2 1/2" WOOD CASING - STAINED I I/2" x WOOD JAMB - STAINED 5/8" x WOOD STOP - STAINED SOLID CORE WOOD DOOR STAINED 5/8" GYP BD. -EACH SIDE MATCH EXISTING DOORS AND FRAMES WOOD FRAME DETAIL SCALE: 1-1/2' • 1'-0" SECTION DOOR SCI-4WULE E1,E2 EXISTING 3'XT' 5C WOOD DOOR AND WOOD JOAM155, LOCKSET 1,2 NEW OR REUSED 31-0"X1'-0" SC WOOD DOOR AND UJOOD JAMBS (TO MATCH EXISTING), 1 1/2 PAIR BUTTS, LOCKSET (INSIDE KNOB TURNS RELY TO EXIT)„ LEVER HANDLES, UJALL STOP AND SILENCERS. WALL SCWEULE WI NEW 3 5/8"X 25 GA STEEL STUDS AT 24" O.C. FROM FLOOR TO CIELING, WITH 5/8" GYP BD EACH SIDE. UINOUJ SCI-4EULE A. NEW 4' WIDE BY 24" TALL WITH SILL AT .5' ,4FF, WOOD JAM6 TO MATCH EXISTING DOORS, l/4° CLEAR POLISHED PLATE ROOM SC4EULE I. REMOVE EXISTING CARPET AND BASE, INSTALL NEW BUILDING STANDARD CADET AND BASE. 2. REPAINT ALL WALLS WITH BUILDING STANDARD PAINT. * ACCENT UJALL PAINT BOTH SIDES FOR WALLS GREATER THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE 12ga. WIRES SPLAYED a 45 TO AN EYE SCREW a ROOF AND TOP OF WAL ATTACH TOP RUNNER TRACK TO CEILING GRID WITH 2 - .6 x 11/8" LONG SCREWS AT 2'-0" O.C. ■■■■■■■■■■■■■■■■■�1■■■■■■■■■■■► TYPICAL STUDS WALL PER SCHD. (FOR UJALL INSULATION SEE PLAN) 5/8" GYP. ED. EA. SIDE (FLUSH FINISH). NORTH 29'-5" COMMON PATH OF TRAVEL 60 LF TO POINT OF TWO EXITS. FLOOR PLAN: NEW SCALE: 1/8" = 1'-0" USE: ALL OFFICE, 1,331 SF SF, OCCUPANT LOAD : 13 OCCUPANTS WITH SINGLE EXIT * ACCENT WALL PAINT BOTH SIDES SEE REFLECTEDAL CEILING FLAN TNT. UJ1ALL TO REFLECTED CEILING SCALE: I-I/2" " 1'-0" SECTION TYPICAL WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHORS, HILTI OR APPROVED 1" EMBEDMENT 0.131" DIA AT 24" O.C. BASE e CARPET UJALL TO 5L 413 SCALE: 1-1/2" " 1'-0' REVIEWED FOR ODE COMPLIANCE APPROVED JUL 1 1 2014 • City of Tukwila BUILDING DIVISION 5/8" GYP. BD. ACOUSTICAL BLANKET s SOUND WALL. CONC. SLAB ON GRADE CAULK GYP. BD. TO FLOOR a ALL SOUND AND INSUL. WALLS SECTION 0225 C VA V W —3 a w i 06-30-14 a 0 4 DESCRIPTION 0_ t— rn(0 coto co M co to .d- d' N c0 c0 00 N N A PROPOSED TENANT IMPROVEMENT FOR: JOE WAGNER (EXISTING) d ca RECEIVED CITY OF TUKWILA , JUL :0 2 2014 PERMIT CENTER C:\Documents and Settinas\AII Users\Documents1CAD12002\0225 GVA-KM\Tukwila CemmArrP\RtIII min A1SI IITF ( T-1 dwt. T-1 7/9/9111d 1f •AR•19 Aei T-1