Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D14-0226 - RPI DIGITAL PRINTING - EXPANSION
RPI DIGITAL PRINTING 3325 S 116 ST STE 161 D14-0226 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0923049068 3325 S 116TH ST 161 Project Name: RPI DIGITAL PRINTING DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D14-0226 8/6/2014 2/2/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT 207 PO BOX 4900 , SCOTTSDALE, WA, 85261 ROYCE BERG Phone: (206) 230-6648 301180 AVE SE , MERCER ISLAND, WA, 98040 GATEWAY CONSTRUCTION SVS Phone: (206) 621-9111 5602 2ND AVE S , SEATTLE, WA, 98108-2409 GATEWCS992C3 Expiration Date: SELF FUNDED - RPI /Il DESCRIPTION OF WORK: EXPAND EXISTING PRINTING COMPANY INTO ADJACENT SPACE. REMOVE SECTIONS OF EXISTING OFFICES AND RESTROOMS FROM GRID 9-12. INSTALL OPENINGS IN EXISTING DEMISING WALL AT GRID LINES 13 & 16. Project Valuation: $150,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIIB Fees Collected: $3,296.72 Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: 2 WL Date: /6//7_ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permi�iija d agree totheconditions attached to this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 39: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 19: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or Tess. (IFC 906.3) (NFPA 10, 5.4) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 20: Maintain fire extinguisher coverage throughout. 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 27: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1011.6.3) 29: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 33: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 34: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 36: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 40: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 41: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 43: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0601 WALL INSULATION CITY OF TUKt —A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/,www.Tukwila\VA.gov Building Permit No. 'NH— — t .2---)49 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3325 South 116th Street Tenant Name: RPI Digital Printing PROPERTY OWNER RREEF America REIT II Corp. MMMM7 Washington Name: C/O CBRE / Asset Services, Amber Stratton Address: 20415 72nd Ave S., Suite 210 City: Seattle State: Wa Zip: 98101 CONTACT PERSON — person receiving all project communication Name: Royce Berg, LPN Architects Address: 3 011 80th Ave Se City: Mercer Island State: Wa Zip: 98040 Phone: (206) 230-6648 Fax: (206) 320-6647 Email: royce@lpnarchitects.com GENERAL CONTRACTOR INFORMATION Company Name: Gateway Construction Services Bill. Fo Address: 5602 Second Ave South City: Seattle State: Wa Zip: 98108 Phone: (206) 621-9111 Fax: (206) 621-9113 Contr Reg No.: GATEWCS992C3 Exp Date: 03/04/2016 Tukwila Business License No.: BUS-0101708 ter King Co Assessor's Tax No.: 092304-9068 Suite Number: Floor: 1 New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Company Name: LPN Architecture and Planners Architect Name: Royce A. Berg Address: 3011 80th Ave Se City: Mercer Island State: Wa Zip: 98040 Phone: (206) 230-6648 Fax: (206) 320-6647 Email: royce@lpnarchitects.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: None c1!! " 19 — 1)4/V Address: City: State: Zip: H:\Applications\Forms-Applications On Line \201 I Applications \Permit Application Revised - 8-9-I Ldocx 12evisccl: August 2011 bh Page I of 4 BUILDING PERMIT INFORMATIO1 !06-431-3670 Valuation of Project (contractor's bid price): $ 150,000 Existing Building Valuation: $ 5,942,900 Describe the scope of work (please provide detailed information): Expand existing printing company into adjacent space. Remove sections of existing offices and restrooms from grid 9-12. Install openings in existing demising wall at grid lines 13 & 16. Will there be new rack storage? ❑ Yes ©.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 st Floor 48,476 3,160 III-B B, F, S Mezzanine 2,981 III-B B 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 120 Compact: 0 Handicap: 6 Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: © Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes VI No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM (Existing min. quantities in designated flamable lockers adjacent maintenance cage ref line A & 11.) ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. I-I:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 Page 2 of 4 PUBLIC WORKS PERMIT INFO ATION — 206-433-0179 Scope of Work (please provide detailed information): No site work, all interior work. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ..• .Tukwila 0...Water District #125 ❑ ...Water Availability Provided Sewer District ..• .Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline El ...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Geotechnical Report ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ....Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ WO# WO # WO # Private 0 Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water 0 ...Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) 0 ...Sewage Treatment Day Telephone: Mailing Address: City Water Meter Refund/Billing: Name: Mailing Address: State Zip Day Telephone: City State Zip li:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 I?h Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 7(2i/ g0 Print Name: Royce A. Berg, LPN Architects Day Telephone: (206) 230-6648 I Mailing Address: 3011 80th Ave SE Mercer Island WA 98040 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised -8-9-I I.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $96.83 D14-0226 Address: 3325 S 116TH ST 161 Apn: 0923049068 $96.83 TECHNOLOGY FEE $96.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2794 R000.322.900.04.00 0.00 $96.83 $96.83 Date Paid: Wednesday, August 06, 2014 Paid By: RPI Pay Method: CHECK 030527 Printed: Wednesday, August 06, 2014 1:49 PM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $3,199.89 D14-0226 Address: 3325 S 116TH ST 161 Apn: 0923049068 $3,199.89 DEVELOPMENT $3,199.89 PERMIT FEE R000.322.100.00.00 0.00 $1,936.60 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,258.79 WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R2641 B640.237.114 0.00 $4.50 $3,199.89 Date Paid: Monday, July 21, 2014 Paid By: REISCHLING PRESS INC Pay Method: CHECK 030463 Printed: Monday, July 21, 2014 2:03 PM 1 of 1 IRWSYSTEMS -40 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 *-3 INSPECTION RECORD Retain a copy with permit - Project: n r, Type of Inspection: Address: _ 11 / // r t. _ Date Called: Speciaf1nsiructions: VPhone Date Wanted: /�--(0-/4 a.m. :: Requester: No: 4 i Approved per applicable codes. Corrections required prior to approval. COMMENTS: rl PrA-J r(o/tAn+n /1 ft Inspect : - ,-----4-2 --‘-'%__--.. [J \ r n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: l 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: k._, --r - r , ill-, nr, Type of Inspection: E m. . I--• � h t • 16 Add ess: i I-- � / i;,, ST Date Called: _.r__ ,-4- u A ( .�-- nr. ..-_ Special Instructions: `" i' T M --74-7 v / 1 2 Date Wanted: q"3 0 —/4 _a.m.. p.m. Requester: p Phone No: 1 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: 3K (<a JeX i Ins ctor: C.k 'LW Date ` _3C -14 REINSPECTION FEE•REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter-61vd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: �\'� Type of Inspection: k.r(Avylivi Address: ' )s s MP Si- Date Called: R-g-1L1 Special Instructions: / Date Wanted: .m.l Requester: Phone No: 1ot,-'-1S0—,3b 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: \ i \/, 2 I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER i u — Ozz (� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: f?r*/ -- 5, g-P-L_ Address: 332_5- Suite #: S , //67-illS T Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ��if/h- //Ge r _" ialk5g / / e e s) Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: *il 4'3 Date: /©`3// y Hrs.: /, 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an. invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER IU - - -19 7- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Type of Inspection: Address: '33a5-- Suite#: /1 S /f 6 frc-- Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: sA- 1-e5 , D/ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspectorial'/it go__ Date: /@� f/�/ Hrs.: // $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 PLANPI5. IN&C(9UTING SLIP PERMIT NUMBER: D14-0226 PROJECT NAME: RPI DIGITAL PRINTING SITE ADDRESS: 3325 S 116 ST X Original Plan Submittal Response to Correction Letter #, DATE: 07/21/14 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: t ii2j1 Building Division i-- lel ublic Wo s Fire Prevention Structural ol 21)•I'1 CT1--' Planning Division Permit Coordinator R% PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 07/22/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 08/19/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 GATEWAY CONSTRUCTION SRVr'S INC Page 1 of 2 0 Washington State Department Of Labor & Industries GATEWAY CONSTRUCTION SRVCS INC Owner or tradesperson SACCO, RONALD Principals SACCO, RONALD, PRESIDENT NIELSEN, CRISTIAN, VICE PRESIDENT Doing business as GATEWAY CONSTRUCTION SRVCS INC WA UBI No. 602 086 011 5602 2nd Ave. S. SEATTLE, WA 98108 206-621-9111 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GATEWCS992C3 Effective — expiration 02/26/2001— 03/04/2016 Bond TRAVELERS CAS & SURETY CO Bond account no. 105165492 $12,000.00 Received by L&I Effective date 08/21/2008 08/19/2008 Expiration date Until Canceled Bond history Insurance Travelers Indemnity Company Th Policy no. DTC0527D0333IND12 $1,000,000.00 Received by L&I Effective date 07/29/2014 08/01/2012 Expiration date 08/01/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602086011 &LIC=GATEWCS992C3&SAW= 08/06/2014