HomeMy WebLinkAboutPermit D14-0231 - SEATTLE FAVORITES BAKERY - TENANT IMPROVEMENTSEAT1'LE FAVORITES
BAKERY
951 INDUSTRY DR
D14-0231
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.sov
2523049034
951 INDUSTRY DR
DEVELOPMENT PERMIT
Project Name: SEATTLE FAVORITES BAKERY
Permit Number: D14-0231
Issue Date: 8/22/2014
Permit Expires On: 2/18/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
CWWA TUKWILA 1 LLC
PO BOX A-3879 C/O EQUITY OFFICE
MGMT LLC, CHICAGO, WA, 60690
DAVID KEHLE, ARCHITECT
1916 BONAIR DR SW , SEATTLE, WA,
98116
ALEXEEV CONSTRUCTION
PO BOX 731152 , PUYALLUP, WA,
98373
Phone: (206) 433-8997
Phone: (253) 230-4788
ALEXECS934P9 Expiration Date: 10/29/2015
SELF -FUNDED
DESCRIPTION OF WORK:
SEPARATE SPACE 951 FROM 953, COMBINE 953 & 955 FOR SEATTLE FAVORITES BAKERY. SPACE ADJACENT AND
EAST OF THESE SPACES; 951 WILL BE A VACANT SPEC SPACE. REMOVE EXISTING NON -BEARING WALLS AS
SHOWN. REMOVE EXISTING DOORS, INFILL OPENINGS AT 951.
Project Valuation: $11,500.00
Type of Fire Protection: Sprinklers: YES
Fire Alarm:
Type of Construction: VB
Fees Collected: $557.86
Occupancy per IBC: B
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
Permit Center Authorized Signature: �r 1
I hearby certify that I have read and el -d this permit and know the same to be true and correct. All
provisions of law and ordinances gove his work will be complied with, whether specified herein or not.
Date:
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to l conditns ttached to this permit.
Signature:_
Print Name:
Date:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for
nonstructural components. ASCE 7, Chapter 13.
5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall
be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay
bracing.
6: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage
over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic
events. The design and calculations for the anchorage or bracing shall be prepared by a registered
professional engineer licensed in the State of Washington. Periodic special inspection is required during
anchorage of storage racks 8 feet or greater in height.
8: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
10: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles
shall be ventilated in accordance with the applicable provisions of the International Mechanical Code.
11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
25: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All
Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC
906.3) (NFPA 10, 5.4)
16: Maintain fire extinguisher coverage throughout.
17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge
or effort. (IFC 1008.1.8.3 subsection 2.2)
18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automaticallyretracted when the
door handle is engaged from inside the tenant space. (IFC Chapter 10)
19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by
Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of
the wrist to operate. (IFC 1008.1.9.1)
23: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or
partitions may require relocating and/or adding automatic fire detectors.
24: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may
require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437)
22: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
26: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that
set forth in Table No. 803.9 of the International Building Code.
21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE FINAL
0409 FRAMING
0502 LATH & GYPSUM
0406 SUSPENDED CEILING
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
v�L Ikvvv
Building Permit No. i y—N-3 /
Project No.
Date Application Accepted:
Date Application Expires:
0 l /1a-/LS
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: f/ t 1 5 11%12.JSIPAI Pt WE
Tenant Name: Rwier'EG, FLV-M4/
PROPERTY OWNER
1�
Name h pcea n t hi evt7
Gyre Address: /.,31 L4,� 6,x,Qi GN t„ 4
Cityn311.4 State:im Zip:qi1ga
CONTACT PERSON — person receiving all project
communication
�,rr1� Kokat ,,i
Name: tr�l i i v f /t L V, t 1 ��i�j/ti [ iet .
Address: ICI it, futile Dew
VISState:
City: �j q .�-� r Zipectil w
Phone:/ ,,35 .t i,14 Fax:A,M_ , t4(_ &% et
Email:
/elik e ei bei,k, tr,), io (
GENERAL CONTRACTOR INFORMATION
Company Name:
Address:
TEO
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docs
Revised: August 2011
bh
King Co Assessor's Tax No.: 2 !Z"' 03' Di
Suite Number: Floor: 1
New Tenant: ( Yes ❑..No
(cp14.10lu4 (Kist -Ng 1]litslitir
ARCHITECT OF RECORD
Company Name: GNI p kiatuf , itoi H i i2 t
1 tlJ�
Architect Name:
awt ° j tt L
rt*
Address:
ICI iv
i'y�„ , si a. e am
�..GTID
City: Sttattee\ v i Zip _ 81)(Q
Phone/yao 4,33 (0_
mg}. Fax:IrvAlt 9
Email:
ENGINEER OF RECORD
Company Name:
4
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: //%,sit
ea
_"n ,
I�V
Address:
City:
State:
Zip:
Page 1 of 4
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ I liOt ?
Existing Building Valuation: $ 1 /LLic t j
Describe the scope of work (please provide detailed information):
GCE k cc ' d► . ' �"rt � )
erfA ILA., elfC VVc irr / G acc
PIWE rkr-'I'It.14 � 1 wes144 WbWg 6��. 1r41.1 FaltiVE 005114 ( j, 11IF11L i)1046,61tel*
-� I
Wt 1 there a nex rac storage? ❑ Yes 130.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
I' Floor
it
4 ,.,,r
v
V �
�•,—
,�J
2nd Floor
I
3rd Floor
Floors thou
Basement
Accessory Structure*
Attached Garage
RECEI=
i .._ I
Detached Garage
CI FY
Of T`l: K ''";/ I(t,A
Attached Carport
P A
UG 0 8 n lii
t o 3 '�
Detached Carport
PERMIT
CENTER
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Lb C PIb u4E Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that theiprinc'pal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Lb Compact:
0 ( No If "yes'', explain:
`�, FIRE ' R I - ON HA . ARDOU MATE ' AL (e\)4
b'�1 �'[ Sprinklers Automatic Fire Alarm ❑ None 0 Other (specify)
Will there be a change in use?
Yes
Handicap:
Will ere .e sto •ge sr use of e, combust►e o ..i:rious materials in the building? 0 Yes No
If 'yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safe Data Sheets.
SEPTIC SYSTEM
0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H \ ApplicationsWorms-Applications OnLine',2o1IApphcations\ Permit Application Re, ised-8-9-11.does.
Re,ised: August 21111
bh
Page 2 of 4
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ I
Existing Building Valuation: $ 1 MlloGi61J
Describe the scope of work (please provide detailed information):
61,1 �% OfiM eAL IE clos# - i laVb>2 Me-vr
G' E k9sceizr dao of rrtevx j
1r11 WIw 1ANr G bck
Peiriwe KCI'I"it-I4 Pou. e3¢lkict Wbu<, 49 ►.I , Px116V6 D(191-14 , ICI
Wt 1 there e ne rac storage? ❑ Yes X.. No If yes, a separate permit and plan
OR13 I LIGS G(9l/
mittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IIBC
1st Floor
%
_ f o
/
,'
,
ye?.
,
!/
2nd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
,'..7
PLANNING DIVISION:
Single family building footprint (area of foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide following:
Lot Area (sq It):! C E Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation thshows that the prnc ppaal owner lives in one of the dwellings as his or her primary residence.
Number of Parking StallsProvi.: Standard: Lb Vfl8IJCj€7 Compact: Handicap:
Will there be a change in use? 0 Yes 0( No If "yes', explain:
FIRE PR 1 TE TIO ZARD 1 MA ERIALS:
`7"'l Sprinkle'. 0 Automatic Fire Alarm 0 None 0 Other (specify)
Will there be storage . use of flammable, combustible or hazardous materials in the building? ❑ Yes No
1f `yes', attach st of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safe Data Sheets.
SEPTIC SYS M
Q On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
fi \Applicatioiu\Forms-Applications On Line1201I Applications\Pemdt Application Revised - 8-9-11.docv
Revised: August 2011
bh
Page 2 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AGENT:
Signature:
Print Name:
Qvio
Date: i Iz . l4-
Day Telephone: wR 43 S "f"1l
Mailing Address: ri UP D144 Po 4cbjit tub e - VD 4 l tp
City State Zip
H:\Applications\Forms-Applications On Line\20l 1 Applications\Permit Application Revised - -9-1 l.docc
Revised: August 2011
bh
Page 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
I ACCOUNT ( QUANTITY I
PAID
$346.28
D14-0231 Address: 951 INDUSTRY DR
Apn: 2523049034
$346.28
DEVELOPMENT
$330.00
PERMIT FEE
R000.322.100.00.00
0.00
$325.50
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE
$16.28
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2919
R000.322.900.04.00 0.00
$16.28
$346.28
Date Paid: Friday, August 22, 2014
Paid By: ALEXANDR A ALEXEEV
Pay Method: CREDIT CARD 022541
Printed: Friday, August 22, 2014 8:19 AM 1 of 1
CRWSYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$211.58
D14-0231 Address: 951 INDUSTRY DR Apn: 2523049034
$211.58
DEVELOPMENT
$211.58
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R2649
R000.345.830.00.00
0.00
$211.58
$211.58
Date Paid: Tuesday, July 22, 2014
Paid By: DAVID KEHLE
Pay Method: CREDIT CARD 005383
Printed: Tuesday, July 22, 2014 2:03 PM 1 of 1
CRWSYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
b!r_o'
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
SeAle
it-K-914
Type of inspection:.
f30` 13 •,
'uAL
Address:
Date Ca d:
Special Instructions:
/
/
`)
Date Wanted:
~1arraf
Requester:
�'
nee No:
4'7 WE(
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
op r " /—k o\e l)
i
,e2%
Inspector:
II
Date:
REINSP ECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431-2451
(206) 431-3670
Project: ii
Se /-e 8A
Type of Inspection:
-rAmv
ci Ad:ess t ,_,i A n `�\
Date Called:
Special Instructions:
� ,� , ' C� ' ) ` Y
/
Date Wanted: a<m,
k.. . > .. l �p.m.
{
Requester:
7Pho9 ne No: s 23 9 f 4 1C3
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
I) / )1\k".
1 t
r ipA r AA . a r\ NIA. l< S
( 1 1 .s Q A \_ J (-) ,--
1
4' i k \1��-- 1r‘1 (k 4-, r 0 tAJ/ frril f '\„S
-1-7) D..)rn i' ter S7ofi((c f. rAi
.' AA L.N. c A. c re C- J f S 1 CE M J Jeji
Inspector:
- 0)<_ )\-
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Date:
i
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project:
-g '/
Type of Insp ction:
Address:
Suite #:
' Jr.Dc451-4"( briv..
(S) -- 9 s3 - S
'
Contact rson:
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
+,ram �f�rnw�
Fr,f_ Ass
Yu,o ILe
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: az_ / ,i 3
Date: t5/7 4, // y
Hrs.:
/ .
0
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
,Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3
Envelope Summary
ENV -SUM
2012 Washington State Energy Code Compliance Forms for Commercial. Groun R1 and N a ctnnr R2 & R3
Revised June 2013
Project 1nfa a/
R
01°C
`
Project Address j 4 u . Are 18
Date tj
lasilla •
/ r
r P (ti�DI''1-¢� P�
For Buildin.
-t�
Dep ' •:"ti) FC
CODE COMPLIAI
APPROVED
AUG 21 2014
Applicant Name: fay iv 1%14� ` �,z .r '
Applicant Address: like u44642,1,1aw Mgsin, •a,E16 ,
Applicant Phone: 'Wtx , em-
Project Description
of Ocqupa_ncyylCondttioni
t%IIVIS
❑ New Building • Addition - Alteration • Chan• :
Compliance Path
0 Prescriptive 0 Component Performance
0 Total :
il�•in�(
Occupancy Group
ok Commercial 0 Group R (R-1 & > 3 story R-2 and R-3)
Climate Zone
•
0 Climate Zone GJIj 0 Climate Zone It‘( See WSEC 301.1 for county list)
Vertical Fenestration and
Skylight Area Calculation
If complying via the Prescriptive path,
provide values for vertical fenestration,
skylights, gross walls and roof. If
complying via the Component
Performance path, these values are auto-
filled by the ENV-t!A form and cannot be
edited here.
Total Vertical Gross Exterior
Fenestration Above Grade % Vertical
(rough opening) divided by Wall Area times 100 equals Fenestration
X 100
Gross Exterior
Total Skylight divided by Roof Area times 100 equals % Skylight
X 100
Maximum Prescriptive
Fenestration Area
Vertical RECEIVED
Fenestration CITY OF TUKWI
Skylights JUL 22 2014
50% Floor Area in DLZ
0 More than 50% of the floor area in daylight zone per C402.3.1.1 PERMIT CENTE
Semi -Heated Path
0 Project has semi -heated areas as defined per C402.1.4
and has a max. heating system
for requirements.
other conditioned spaces— provide
or Component Performance compliance
spaces shall comply with
• Applying wall exception to semi -heated areas
1. To be deemed semi -heated the area is heated but not cooled,
output capacity between 3.4 — 8 Btuh/ft2. Refer to C402.1.4
2. Semi -heated spaces shall be documented separately from
separate compliance forms for each conditioned area type.
3. Semi -heated spaces may comply under the Prescriptive
path.
4.Envelope elements separating semi -heated from other conditioned
thermal envelope requirements for an exterior wall.
Refrigerated Spaces
freezer
of Occupancy/Conditioning
only. Compliance documentation for
the ENV -PRESCRIPTIVE form. Refer
■ Walk-in cooler 0 Walk-in
El Refrigerated Warehouse Cooler 0 Change
Refrigerated spaces shall comply under the Prescriptive Path
these areas may be combined with non -refrigerated areas in
Mixed Occupancy and/or
Space Conditioning
Project includes more than one occupancy type and/or level of space conditioning. Multiple
compliance forms may be required. Select all that apply to scope of project:
0 Commercial 0 Group R1 or >3 story R2/R3 ❑ Refrigerated Space
❑ Fully Conditioned 0 Semi -Heated ❑ Low Energy*
Group R2/R3 < 3 story
*Low energy areas are exempt from all thermal envelope provisions and compliance forms for
these areas are not required. Refer to C/0/.5.2 for exemption.
u% efrio.ge7 `6 5U1LDitl4 FUt,tiopE i7tL4_O23 i'
VCE
ON
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Interior Lighting Summary
LGT-SUM
2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 and R3
Revised June 2013
Project Info
Project Address Oaltlit lima' T - ,
Date 1 i , �
� F------
��/,'�i Ct9/'� 141)1619,1 Ho'c
P'/i V�
For Building Depa
ent se
Applicant Name: .' `
Applicant Address:
Pnibie P y't '► wE Vb.
ant Phone:
Applic.
�� '�1�4 4."
Project Description
New Building ❑ Addition g Alteration
•
■ Plans Included
Lighting Compliance
Path
o Lighting Power Density Calculations 0 Total Building Performance
(if Total Building Perfonnance then only LGT-CHK is required.)
Interior Lighting
Compliance Option
O Building Area Method O Space -by -space Method
Interior Lighting System
Description
Briefly describe lighting
system type and features.
Additions and
Change of Space Use (C101.4.3 & C101.4.4)
area or Change of Space Use area complies with all applicable provisions as stand alone project
area or Change of Space Use area is combined with existing building lighting systems to demonstrate
with all applicable provisions
Building Area Method (LTG4NT BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum
and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting
per C405.2 and commissioning of lighting controls per C405.13.
a Addition
mi Addition
compliance
Provide
allowed
controls
Alterations, Renovations and Repairs (C101.4.3.1)
❑ 60% or more of luminaires in space replaced
Provide Building Area Method (LTG-iNT-BLD) or Space -By -Space Method (LTG-1NT-SPACE) Compliance Form. Document maximum
allowed and proposed (including existing) lighting wattage of project scope
60% of luminaires in space replaced
Space -by -space Method (LTG-INT-SPACE) Compliance Form. Document existing total wattage in space and proposed
existing) lighting wattage of project scope
• Less than
Provide
(including
0 Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased
❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit
Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific
application controls (C4052.3), and commissioning of lighting controls per C405.13
lighting panel
all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of
controls per C405. 13.
• New or moved
Provide
fighting
reconfigured - luminaires unchanged or moved only
all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13.
• Space is
Provide
,-+per No changes are being made to the interior lighting and space use not changed.
HERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D14-0231
DATE: 08/07/2014
PROJECT NAME: SEATTLE FAVORITES BAKERY
SITE ADDRESS: 951 INDUSTRY DR
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
Building Division ❑
Public Works ❑
Fire Prevention
Structural
111
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 08/12/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
n
Corrections Required ❑
(corrections entered in Reviews)
Notation:
DUE DATE: 09/09/14
Approved with Conditions
Denied
(ie: Zoning Issues)
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D14-0231
DATE: 07/22/2014
PROJECT NAME: SEATTLE FAVORITES BAKERY
SITE ADDRESS: 951-955 INDUSTRY DR
X Original Plan Submittal
Response to Correction Letter #
Revision #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
ifwc
7 41
But ding Division
s Olm-29.11
Public Works EMI
Cr y -�yl CA, ILIA D1 `i* I1
Fire Prevention ® Planning Division
Structural
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 07/24/14
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 08/21/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED: 8 ^ I— ` 1
Departments issued corrections: Bldg ❑ Fire Ping ❑ PW 0 Staff Initials:
12/I8/2013
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ i WC-0 Existing Building Valuation: $ 1 tit I 4L-sN
Describe the scope of work (please provide detailed information):
&Qk°I-6 f ri TO/ GI NL ic cietso » —t) 'floe ITe4 M
Oa !vita- ' alb ' lit 2)
ij WILL, L. Visa i.i'i'
Pena r)(6no4 1\b4. ailtwc NSriklci riZee2, -bitiGS, -4
�.t-- t
Wi 1 there e new rac storage? ❑ Yes X.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Constriction per
IBC
Type of
Occupancy per
IBC
tS` Floor
/i3G%2
L--
Igo �`�mo
�
/
'Ye?
F2
2nd Floor
3rd Floor
I
Floors thni
Basement
Accessory Structure*
Attached Garage
IlECEIV'ED
CITY OF TUKWII
A
Detached Garage
Attached Carport
Detached Carport
2014
Covered Deck
PERMIT CENTER
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): tC.L-1JC Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that theiprine'pal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Lk) OCiee2 Compact: Handicap:
Will there be a change in use?
FIRE
❑ Yes
ARDOUS MATERIAL
Automatic Fire Alarm
;`''` No If "yes", explain:
❑ None
Other (specify)
Wi11 Mere •e stor ge'r use of .- :. e, combust • e o .rar.ous materials in the building? 0 Yes No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safe Data Sheets.
SEPTIC SYSTEM
❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\ApplicationsWorrns-Applications On Line.2011 Applications \Permit Appl icatton Res lsed - 8-9-11-dace
Revised: Aueust 201 t
hh
Page 2 of 4
71114 113
david
kehle
it_
August 6, 2014
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
Attn; Mr. Al Metzler
RE: Seattle Favorites Bakery
D14-0231
951 Industry Dr.
or),
TIN-
406
pF 72014
TER
Pkyi4
Dear Mr. Metzler,
I am in receipt of your comment letter #1 and have addressed those as follows;
1 I have changed the SD-1 sheet to reflect the building not being sprinklered but
with a fire alarm system. This only impacted the SD-1 sheet
I have also changed the separate permits on sprinkler to not be required as noted on
sheet SD-1.
I trust this will answer your comments and I look forward to the permit.
Sincerely,
David Kehle
DK/dk
Encl: 4 Sheets SD-1
1916 Bonair Drive S.W.
Seattle, WA 98116
(206) 433-8997
fax (206) 246-8369
email: dkehle@dkehlearch.com
City of Tukwila
Department of Community Development
August 06, 2014
DAVID KEHLE, ARCHITECT
1916 BONAIR DR SW
SEATTLE, WA 98116
RE: Correction Letter # 1
DEVELOPMENT Permit Application Number D14-0231
SEATTLE FAVORITES BAKERY - 951 INDUSTRY DR
Dear DAVID KEHLE, ARCHITECT,
Jim Haggerton, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments.
• This submittal is for a tenant improvement of a fully sprinklered building. The building is NOT SPRINKLERED
and has an automatic fire alarm system. Please correct the documents and re -submit for a tenant improvement in a
non-sprinklered building.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-431-3655.
Sincerely,
Bill Rambo
Permit Technician
File No. D14-0231
L9fin - __. TI__.1__.-__.I 0.. t._ lL111/1 - T__1_._• 1_ T1J__1 .
110100 - 111. _ An/ A01 _ i+ "rt.-
w11 �ii�
City of Tukwila
Department of Public Works
July 25, 2014
Kidder Mathews
631 Strander Blvd., Suite G
Tukwila, WA 98188
RE: Seattle Favorites Bakery
951-955 Industry Drive (Bldg. #29), Tukwila, WA
Permit No. D14-0231
To Whom It May Concern:
Jim Haggerton, Mayor
Bob Giberson, P.E., Director
In accordance with Washington State Department of Health guidelines for Group A Public Water
Systems, Public Works has implemented a cross -connection control program to protect the public water
system from contamination via cross -connection. Since the project includes alterations to the existing
plumbing system, the entire plumbing system must be brought up to the current standards as set forth in
the Uniform Plumbing Code, including installation of approved backflow prevention on the fire line and
the domestic water supply to the building. The City has determined that the subject building has
deficiencies on the domestic water line.
a) Domestic Water
A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow
Assembly (RPBA), shall be installed immediately downstream of the existing permanent water meter.
Installation at another location requires the Public Works Director's approval. The RPPA shall be
installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick
concrete pad. Public Works strongly recommends a power supply be provided for the freeze
protection enclosure.
On your site plan, please show the property line(s), street name, North arrow, building location, and
size of existing permanent water meter and proposed RPPA. Show manufacturer name and backflow
model number. Submit RPPA cut sheet and circle backflow to be installed.
I have enclosed Development Bulletins C5 and A9, which spells out design and installation requirements
for cross connection control.
The Public Works Director will withhold issuance of the Seattle Favorites Bakery permit until the Permit
Center receives plans for installation and test results of subject backflow devices or a bond for domestic
water RPPA installation.
Backflow installation triggers a Public Works Type C construction permit for which Public Works
collects a base application and plan review fee ($250.00 plus 2.5% of construction cost for RPPA
installation and backflow testing) when the application is submitted. An additional 2.5% of subject
construction cost will be assessed at the time of permit issuance. You need to supply the installation plans
consisting of a schematic that clearly shows the location of the proposed RPPA in relationship to the
D14-02.31
6300 Soutlzcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-433-0179 • Fax: 206-431-3665
Joanna Spencer
From: Todd Reedy
Sent: Wednesday, July 23, 2014 11:22 AM
To: Joanna Spencer
Subject: RE: Sea Bakery TI @ 951-955 Industry Dr (BLDG #29)
Hi Joanna,
Regarding Building #29, 951-955 Industry Drive:
- No RPBA installed on 1.5" domestic service for premise isolation.
-No fireline connection to this building.
- Irrigation is connected to another service.
Have a great day,
Todd
From: Joanna Spencer
Sent: Wednesday, July 23, 2014 8:48 AM
To: Todd Reedy
Cc: Han Kirkland; Joanna Spencer
Subject: Sea Bakery TI @ 951-955 Industry Dr (BLDG #29)
Good Morning Todd,
Are they current on their backflows?
ALEXEEV CONSTRUCTION SVCc LLC
Page 1 of 2
Washington State Department of
Labor & Industries
ALEXEEV CONSTRUCTION SVCS LLC
Owner or tradesperson
ALEXEEV, ALEXANDR A
Principals
ALEXEEV, ALEXANDR A, MANAGER
ALYEKSYEYEV,
OLEKSANDR, PARTNER/MEMBER
(End: 10/14/2013)
Doing business as
ALEXEEV CONSTRUCTION SVCS LLC
WA UBI No.
602 767 386
PO BOX 731152
PUYALLUP, WA98373
253-230-4788
PIERCE County
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
ALEXECS934P9
Effective — expiration
10/29/2007-10/29/2015
Bond
CBIC
Bond account no.
SF2145
Received by L&I
10/29/2007
Insurance
Ohio Security Ins Co
Policy no.
BKS53146520
Received by L&I
10/30/2013
$12,000.00
Effective date
10/22/2007
Expiration date
Until Canceled
$1,000,000.00
Effective date
11/16/2013
Expiration date
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602767386&LIC=ALEXECS934P9&SAW= 08/22/2014
!BUILDING 4 SITE STATISTICS
BUILDING CODE:
ZONING:
SEISMIC ZONE:
CONSTRUCTION 'TYPE:
OCCUPANCY GROUPS:
ALLOWABLE BUILDING AREA:
NO CHANGES TO PA
IBC 2012
M-1
ZONE 3
V-B SPRINKLERED
1
60' A' . 0 AL S DES,
NON-SPRINKLERED, FIRE ALARM
NO CHANCES TO EXTERIO
NO CHANGES TO BUILDING ENVELOPE
AREA OF TENANT: SPACES 953 AND 955 =2,352
SF TENANT SPACE
OFFICE (5) = 416 SF
WAREHOU8E(S1) = 1,815 SF
TENANT SPACE 951 = 1,112 SF OFFICE (5)
AREA OF REMODEL: 950 SF
ESTIMATED COST: $ 11,000
TAX I D. #
252304-$034-01
LEGAL
THAT PORTION OF THE SOUTHWEST
QUARTER OF SECTION 25, TOWNSHIP 23
NORTH, RANGE 4 EAST, W.M., IN KING
COUNTY, WASHINGTON, MORE
PARTICULARLY DESCRIBED AS
FOLLOUJS:
COMMENCING AT THE EAST QUARTER
CORNER OF SECTION 26, TOWNSHIP 23
NORTH, RANGE 4 EAST W,M.*
THENCE NORTH 88D06'42" WEST
ALONG THE EAST -WEST CENTERLINE
OF SAID SECTION 26 A DISTANCE OF
105.84 FEET±
THENCE SOUTH 01041128" WEST 90.66
FEET±
THENCE SOUTH 88D12132" EAST 233.00
FEET TO THE TRUE POINT OF
BEGINNING±
THENCE FROM THE TRUE POINT OF
BEGINNING SOUTH 88D12'32" EAST
223.00 FEET TO A POINT ON THE
CENTERLINE OF A PRIVATE DRIVE:
THENCE ALONG SAID CENTERLINE
SOUTH 01D47'28" WEST 511.11 FEET TO
A POINT OF CURVATURE:
THENCE TANGENT TO THE PRECEDING
COURSE ALING THE ARC OF A CURVE
TO THE LEFT, A DISTANCE OF 11.18
FEET, HVING A RADIUS OF 250.00
FEET AND A CENTRAL ANGLE OF
1tD49133" TO A POINT OF REVERSE
CURVATURE ±
THENCE FROM A TANGENT WHICH
BEARS SOUTH 16D02'05" EAST ALONG
THE ARC OF A CURVE TO THE RIGHT,
A DISTANCE OF T1.18 FEET, 14AVING A
RADIUS OF 250.00 FEET AND A
CENTRAL ANGLE OF 17D49133" TO A
POINT OF TANGENCY± THENCE
TANGENT TO THE PRECEDING CURVE
SOUTH 01D41'28" WEST 430.00 FEET
TO A POINT ON THE NORTI-4ERLY
MARGIN OF MINKLER BOULEVARD±
THENCE LEAVING SIAD CENTERLINE
ALONG SAID MARGIN NORTH 88012'32"
WEST 251.00 FEET±
THENCE LEAVING SAID MARGIN
NORTH 01D4T28" EAST, 116023 FEET
TO THE TRUE POINT OF BEGINNING.
SEPARATE PERMITS:
PLUMBING
HVAC MODIFICATIONS
ELECTRICAL
SCOPE OF WORK
SEPARATE SPACE 951 FiROM 953, COMBINE 953 AND 955 TO SEATTLE
FAVORITES SPACE ADJACENT AND EAST OF THESE SPACES.
SPACE 951 WILL 5E A VACANT SPEC SPACE.
REMOVE EXISTING NON 5EARING WALLS AS SHOWN, REMOVE EXISTING
DOORS, INFILL EXISTING OPENINGS AT 951, CREATE NEW OPENINGS
BETWEEN, 953 AND 955 AND SEATTLE FAVORITES BAKERY. ALL PER PLAN
SEPARATE PERMIT
REQUIRED FOR:
eerMechanical
'Electrical
Plumbing
gas Piping
City of Tukwila
EL,ilt..D:N i? o,/d^JCJN
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE.: Revisions will r ^quire a new plan submittal
ti and may in 'ude additional plan reviisw fees.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 21 2014
a :64A
City of u wila
BUILDING ISION
Industry Drive Buildings 19-31
BUM
I
EMS
Tukwila Commerce Center
9C7!M
9Ca•^d
9t:<?.4
921)M
,4,1,1%:-..rVEIRAILL SITE PLAN:
NORTI-I NO SCALE
rii-cc V157E---.
RECEIVED
CITY OF TUKWILA
AUG 0 8 2014
COPY
Permit No.FILE Dt L ,-
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any ads • ed code • ordinance. Receipt
of approved Field Copy ►.14 cond I ► 4 is ackno ged:
WitaltPA
WPM
By:
Date:
City of Tukwila
BUILDING DIVISION
CORRECTION
0225 GVA
w
a
m
0
4
1
0
1.
DESCRIPTION
w
w
0
fa
1r
N
N
0
0 0
SEATTLE FAVORITES BAKERY
A PROPOSED TENANT IMPROVEMENT FOR:
rzi
z
0
0
0
0
WASHINGTON
BUILDING 29
SD=1
0
PERMIT CENTER
DV -it 02 ; I
C:\Documents and Settings\ Il Users\Documents\CAD12002\0225 GVA-KM\Tukwila Commerce\955 BLDG 29 BAKERY1sd-1.dwg, SD-1, 8/6/2014 4:19:19 PM
EX. OFFICE
EX. CONF
EX. OFFICE
EX. OFFICE
EX.
RESTROOM
EX. OFFICE
r
-I
EX. OFFICE
EX. OFFICE
EX. OFFICE
EX. LUNCH
EX. OFFICE
EX.
WAREHOUSE
AND
PRODUCTION
EX. FREEZER
EX.
WAREHOUSE
CI
8'-0" /4'-
NEUJ DOOR AND OPENING SC-1EULE:
1 NEW AND OR RE USED 3'-0"X1'-0" SC WOOD DOOR AND WOOD JAMB (POOR AND JAMB TO
MATCH EXISTING), LATCHSEi (LEVER HANDLE), WALL STOP AND SILENCER
2,3 NEW 8'-0" WIDE X FULL HEIGHT OPENING (12' TO ROOF STRUCTURE) OR MINIMUM 8' AFF WITH NEUJ
BOX HEADER (6"X20GA)
EXISTING DOOR SCHEDULE:
El EXISTING 3/X1/ STOREFRONT DOORS WITH SAFETY GLAZING (ADD EXIT PADDLE)
E2 EXSITING PAIR OF 3'XTHMTL DOORS AND FRAMES, WITH LOCKSET (INSIDE KNOB TURNS
FREELY TO EXIT.)
E3 EXISTING 3'4' SC WOOD DOOR AND WOOD JAMBS, LATCHSET
E4 EXSITING 3'X-i' SC UJOOD DOOR AND WOOD JAMBS, PRIVACY LOCK
E5 EXISTING 3'X4' SC WOOD DOOR AND UJOOD JAMBS, REMOVE OR REUSE
E6 EXISTING 3'X4' H. MIL DOOR AND FRAME, LCOKSET (INSIDE KNOB. TURNS FREELY TO EXIT)
El EXSITING I0'X10' OVERHEAD DOOR
E8 EXSITING 3'XT STOREFRONT DOORS WITH .SAFETY GLAZING, NO CHANGES
UJ,4LL SCHEDULE:
A IN FILL Ek151NG WALLS OR OPENINGS WITH WOOD OR STEEL STUDS TO MATCH EXISTING
FRAMING, 5/8" GY BD EACH SIDE, PAINT.
REMOVE EX.
WALLS, FLOOR,
DOOR AND
CEILING
REMOVE EX.
WALL FOR NEW
DOOR
EX.
WAREHOUSE
NEW
WAREHOUSE
REMOVE EX
DOOR AND
INFILL
EX.
RESTROOM
E3
NEUJ OPENINGS FOR
ACCESS
EX.
WAREHOUSE
NEW
WAREHOUSE
EX.
STROOM
EX. OFFICE
0-3)
EX. OFFICE E3,
EI
951 953 955
25'-1" 49'-ii"
� FLOO PLAN: DEMO
SCALE: I/8•: 11.0"
\-r
DEMO NOTES:
1. REMOVE EXISTING WALLS, DOORS, AND FLOOR FINISHES PER PLAN
2. REMOVE EXISTING ELECTRICAL ON OR 1 WALS BEING REMOVED, PULL BACK TO A J-BOX, AT ROOF
STRUCTURE AND LABEL WITH CIRCUIT AND PANEL NUMBERS.
3. PATCH AND REPAIR FLOORS, WALLS AND CEILING AS REQUIRED
4. REMOVE EXISTING UN USED DATA AND PHONE CABELING
•
2x4 WOOD STUD WALL (SEE SCHEDULE)
2x WOOD BLOCKING
2 1/2" WOOD CASING - STAINED
I I/2" x UJOOD JAMB - STAINED
5/8" x WOOD STOP - STAINED
SOLID CORE WOOD DOOR
STAINED
5/8" GYP BD. EACH SIDE
UJOOD FRAME DETAIL
SCALE: I-1/2" : I'-0"
SECTION
FOR WALLS GREATER
THAN 8'- 0" IN
WIDTH WITHOUT AN
INTERSECTING WALL,
PROVIDE I2ga. WIRES
SPLAYED • 45 TO AN
EYE SCREW a ROOF
AND TOP OF UAL
0
EX. OFFICE
1uuu•■■lu■■■■uuu.it I■.uu...uu■►
ATTACH TOP RUNNER
TRACK TO CEILING
GRID WITH 2 - 06,
x 11/8" LONG
SCREWS AT 2'-0" O.C.
TYPICAL STUDS WALL PER SCHD.
(FOR WALL NSULATION SEE
PLAN) 5/8" GYP. BD. EA
SIDE (FLUSH FINISH).
SEE REFLECTEDAL
CEILING PLAN
TIP. UJ4LL TO REFLECTED CEILING
SCALE: 1-U2" : I'-0"
SECTION
BOX HEADER, 600 TI50-33 T AND B
2-6005162-33 BOX SIDES
ATTACH T AND B TO Box SIDES WITH .812"
O.C. SCREWS
NEW GYP BD WRAPPED OPENING
TYPICAL WALL
FRAMING
ATTACH BOTTOM
TRACK TO CONC.
FLOOR U/ POWDER
DRIVEN ANCHORS, HILTI
OR APPROVED 1" EMBEDMENT
0.131" DIA At 24" O:C.
BASE a CARPET
WALL TO 5L,4
SCALE:1-1/2" : l'-0"
1
.'BOX HEADER AT
OPENING
SCALE: I I/2° , 11_0"
5/8" GYP. P.
ACOUSTICAL BLANKET
• SOUND WALL.
CONC. SLAB ON GRADE
CAULK GYP. BD. TO FLOOR
® ALL SOUND AND INSUL.
WALLS
SECTION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 21 2014
City of Tukwila
BUILDING DIVISION
EX. OFFICE
EX. CONF
EX. OFFICE
EX. OFFICE
EX. OFFICE
951
z
EX. OFFICE
EX. OFFICE
EX. TEL/DATA
EX. OFFICE
EX. LUNCH
EX. OFFICE
EX.
WAREHOUSE
AND
PRODUCTION
EX. FREEZER
EX.
WAREHOUSE
NEW
WAREHOUSE
A
INFILL EXISTING
OPENINGS
A
EX.
RESTROOM
(0
EX.
WAREHOUSE
\
NEW OPENINGS FOR \
ACCESS
EX.
WAREHOUSE
NEW
WAREHOUSE
EX.
RESTROOM
D
EX. OFFICE
EX. OFFICE
953 955
FLOOR PLAN: NEUJ.
SCALE: 1/8" : 1'-0"
8'-0" 41_0"
f
►L
EX. OFFICE
SCOPE OF WORK:
TO SEGRAGATE SPACE 951 FROM 953 FOR A FUTURE SPEC TENANT, COMBINE 953 AND 955 WITH THE EXISTING SEATTLE FAVORITES BAKERY EAST OF
THESE SPACES.
951 SPACE WILL BE 1,112 SF OF SPACE AT 1/100 = 12 OCCUPANTS, SINGLE EXIT, NO PATHWAY LIGHTING
SPACES 953 IS 1,132 SF OF WHICH 156 SP (2 OCC) IS OFFICE, 916 SF WAREHOUSE (2 OCC) TOTAL 4 OCCUPANTS, SINGLE EXIT, NO PATHWAY LIGHTING
SPACE 955 IS 1,219 SF OF WHICH 320 SF IS OFFICE (2 OCC) AND 899 SF WAREHOUSE (2 OCC) TOTAL 4 OCCUPANTS, SINGLE EXIT, NO PATHUJAY LIGHTING..
RECEIVED
CITY OF TUKWILA
JUL 222014
PERMIT CENTER
w
O
n-
a
n
DESCRIPTION
w
w
p0
O
u_
to
0
w
L4
0
N
0
00
N N
w
z
1<
CL
VAN
S c0
In 0
tz
1
—<
Z
W
mho
(o
O) W
SEATTLE FAVORITES BAKE
WASHINGTON
T-1
d
E2
C:1Documents and Settings\All Users\Documents\CAD\200210225 GVA-KM\Tukwila Commence\955 BLDG 29 BAKERY\T-1.dwg, T-1, 7/21/2014 4:01:04 PM