Loading...
HomeMy WebLinkAboutPermit D14-0248 - BUY BUY BABY - STORAGE RACKSBUY BUY BABY 17686 SOUTHCENTER PKWY D14-0248 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3523049005 17686 SOUTHCENTER PKWY Project Name: BUY BUY BABY Permit Number: D14-0248 Issue Date: 1/23/2015 Permit Expires On: 7/22/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KIR TUKWILA 050 LLC/KIMCO 3333 NEW HYDE PARK STE 100 PROPERTY TAX DEPARTMENT, NEW HYDE PARK, CA, 11042 KERI PUTNAM 161 ATLANTIC ST , POMONA, CA, 91722 COAST TO COAST FIXTURING INC 1229 CORCONET DR , DALTON, GA, 30720 COASTCF9550T BED BATH & BEYOND 650 LIBERTY AVE , UNION, NJ, 07083 Phone: (909) 869-0989 Phone: (706) 259-4014 Expiration Date: 1/21/2017 DESCRIPTION OF WORK: INSTALLATION OF RACKS IN EXISTING BUILDING Project Valuation: $100,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $2,577.02 Occupancy per IBC: M Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No m Permit Center Authorized Signature: tit Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it and agree to the conditions attached to this permit. Signatur 1 �� Print Name: 1 Date: (/)--3L15 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 21: All fire sprinkler work requires a separate submittal and approval of sprinkler drawings by the Tukwila Fire Marshal's Office. 11: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 9: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 8: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 15: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 16: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 17: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 18: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWII Community Developmmiit Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.waus Building Perm o. D114— Q2-.4, Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 11(0'310 1 SOI.I�"iii��f"�►1}fly V) Tenant Name: NAIA CJOX1 Ar, 'AYA \\,w, \NewTenant: ES Yes ❑..No Property Owners Name: '' '�) (A),k 1J S \ a IS r Cooi \- D1( Mailing Address: ll %p J)U�'Me.Y1 V-W TV—\14\\(A city King Co Assessor's Tax No.: Suite Number: Floor: �A °ltlm-6 State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: .0._YV*1 Day Telephone: ck Ft -.-g c -o c 9 Mailing Address: I (.Q Q' C VOIYl i.. eik I �� E-Mail Address: a i'a-h OnS .s-kz_rniC W1 C • LOYV I F x Number: CtOP 'gOat°1 • 0 41 f ZIP GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Phunbing and Gas Piping (pg 5)) Company Name: C�lz,� CAM -- Mailing Address: (L�� f t W \ Contact Person: Q,3)04 4 -3c‘t,DNr\ cip- 1617,0 2 ((�� --\\ (��+ Day Telephone: � 6Y! ' 1- `-1 01 (- E-Mail Address:i(k —CV: O. (,C,balrAy) ��S�f'llt)C\)�(ii`e • I6Y') Fax Number: 1 o ' is : 11.02 Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: INACC-1 P'(' rC.1� , \ f L 'J lrfi ` Mailing Address:1(� t (�t�C- C n`es Tsai\. - z a a • 326 / C�, OH q 1113 I M a City State Zip Contact Person: \ 1 \ k( \"e. t \�--e. 1 Day Telephone: 21( - 6 " (`S/ ,� ( !� "J�' E-Mail Address: C('.��ik-e.@mil cht*eLvre, (OW► Fax NumVber: P' SZO ` (SIY-1 ENGINEER OF RECORD - All plans must, be wet stamped by Engineer of Record Company Name: Sal vrn (., \r . Mailing Address: Ike' PA\Qh ' C. S�• Contact Person: ... r 1 LN-i xw" E-Mail Address: 09-evotii �YIS ���� 2mi Lin.c...c6)1 Q: Wpplicetion,\Fams-Applicmia s On Linen-2006 - Remit Applicationdoc Revised: 9-2006 bh 61.1:ffy‘ct Day Telephone: Fax Number: cA- 9 ar2- state Zip qoa-'gtoC og1R 9*861'7-d92I Page 1 of 6 BUILDING PERMIT INFORMATION - 2067431 3670 Valuation of Project (contractor's bid price): $ \ ( IOU) OD Existing Building Valuation: $ jam, Scope of Work (please provide detailed information): V1DY\ (Cc Y Ck3L s \Y\ ? t \ Will there be new rack storage? [ Yes ❑.. No If yes, a separate permit and plan submittal will be required. rovide All: Building Area s'm Square Footage Below "Interior Remodel %) I `'Floor :.: • Addition to Existing :Structure , . , Type of Construction per IBC Occupancy per;; IBC 2nQ: Floor 3rd' Flo' Eloors> • t Basement • Accessory Structucc*. Attached:garage ,..'.;` i ', Detaclied^.Garagc '�: Attached:Carport • 'Detadhed' Caport:• C.ovcned Deck:: UncoveredDeck, PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: �j- Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellin s as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) r � Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes CI No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Saf Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. QMpplicarions\Fo[me-Applications On Line \ 3-2006 - Permit Application.doc Revised: 9-2006 bh Page 2 of 6 PERMIT APPLICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ARIZED AGENT: Signature: Print Name: t44f\ i V `- 1i'-YYN Mailing Address: l( fOtAalVI L Date Application Accepted: Date Application Expires Day Telephone: City Date: State Zip Staff Initials: IX Q: ApplicationslForms-Applications On Line \ 3-2006 - Permit Application.doc Revised: 9-2006 bh Page 6 of 6 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $1,593.41 D14-0248 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 $1,593.41 DEVELOPMENT $1,517.75 PERMIT FEE R000.322.100.00.00 0.00 $1,513.25 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $75.66 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4133 R000.322.900.04.00 0.00 $75.66 $1,593.41 Date Paid: Thursday, January 15, 2015 Paid By: COAST TO COAST FIXTURING INC Pay Method: CHECK 20384 Printed: Thursday, January 15, 2015 11:39 AM 1 of 1 ��SYSTEMS DESCRIPTIONS Cash Register Receipt City of Tukwila I ACCOUNT I QUANTITY I PAID PermitTRAK $983.61 D14-0248 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 $983.61 DEVELOPMENT $983.61 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2744 R000.345.830.00.00 0.00 $983.61 $983.61 Date Paid: Thursday, July 31, 2014 Paid By: SEIZMIC INC Pay Method: CHECK 32164 Printed: Thursday, July 31, 2014 9:51 AM 1 of 1 CJ SYSTEMS KC INSPECTION NO. re' CITY OF'TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (208) 438-9350 i:/v—Ozve9 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project t5 uk-f- BL.k)r gaby Type_df Inspectiorl_ ,- KacP-- Fem / , 'Addres:S: I 174,9A 2C-f-t• trulki>r Date Called: Special Instructions: Date Wanted: a.rn. P.m. Requester: Cr yrige (et(Cle Phone No: (710-Ig —801- 2)01 6 N.:Approved per applicable codes. OCorrections required prior to approval. Q4i4MENTS: fitOr.„ inspector Dalg: -- 1.7 F REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. (66 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ply-ovilts Project: ic,t)e /Juy eala Type of Inspection: r TP,c7 1 - pc_k_r Address: Im)c 5vef4 C1v Pettsy Date Called: Special Instructions; f /1/#1 Date Wanted: 2- / 3 -, r a.m. P.m Requester: Cr Y cfq 1 kifeksck Phone No: . 969-Sli- s-qi( Approved per applicable codes. [81-Corrections required prior to approval. 1:27/4V2'1' ) t,c) r Lak, inspector Dal - - s REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Reque Lin (206) 438-9350 Project: 1S1 . C. '41.4r7 -Type of Inspection: r - '0i< V /C4 M-C Address; 1703.6 S. Clif Date 'Called: 1 / Special Instructions: )41.1-1 Date Wanted: 2- a.m. P.m. Requester: Phone No: EApproved per applicable codes. Corrections required prior to approval. COMMENTS: PfflA y ta Inspector: Date: fg EREINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter BUM., Suite 109. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:-- --., ,---, -t EA,i >r' ,I Type of I spection: r7— z,,,,:/ / Address: / Suite #: ,/ 76, `6,, S ,L,y . ContactPerson: Special Instructions: ( Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: P • +, /fib ,..-.,,,,,,,A.� -- 6 -kcs ° -A, C ; _,. firc'i`r —'�"" may, c-S /V / / %� { _ /rf /f f f- /` f ---- . & A-2 c^ / [1 . fr 1t - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector. f ` ��fr Date: Z 7/3 / J Hrs.: 2. a / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 NaL ASSOCIATES, INC GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION February 13, 2015 KA No. 066-15017 Permit No. D14-0248 City of Tukwila Attn: Bldg Dept. 6200 Southcenter Blvd Tukwila, WA 98188 RE: Final Letter Buy Buy Baby Racking 17574 Southcenter Pkwy Tukwila, WA 98188 To Whom It May Concern: In accordance with our clients request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: o Proprietary Anchors To the best of our knowledge, all work has been tested and inspected and has been found to be in general accordance with the approved plans and specifications, and engineering revisions, and chapter 17 of the 2012 international Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939-2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC William B Throne Operations Manager Puyallup CC: Bed Bath and Beyond cm( OF TUKWiiA FEB la 2015 PERMIT CENTER With Offices Serving The Western United States 922 — Valley Avenue NW Suite 101 • Puyallup, WA 98371 • (253) 939-2500 • Fax: (253) 939-2556 5, _ - S EtZ? ' ( MIC i t ; )-r j \ INC. .n MATERIIL II ANI)LI\c ENCIIN4RING ESQ' i90-3 SPECIAL PRODUCTS CONVEYORS TANK SUPPORTS TALL SUPPORTS MACHINERY HEADER STEEL RACK BLDGS SORT PLATFORM SHEDS PICK MODULES MEZZANINES ROOF VERIFICATION FOOTINGS ED OCT 07 2014 City of Tukwila v OU L DIVISION RECEIVED CITY OF TUKWILA SEP 1 6 2014 PERMIT CENTER STORAGE RACKS OTHER SERVICES SELECTIVE SEISMIC ANALYSIS DRIVE-IN PERMIT ACQUISITION PUSH BACK EGRESS PLANS FLOW RACK STATE APPROVALS CANTILEVER PRODUCT TESTING LICENSED IN ALL 50 STATES SEISMIC ANALYSIS OF STORAGE RACKS FOR BUY BUY BABY #3098 17686 Southcenter Parkway Tukwila, WA 98188 JOB #:14-1157 SHELVING METAL METAUWOOD MOVABLE GONDOLAS LOCKERS CATWALKS SPECIALS PRODUCTS SHUTTLES VLM CAROUSELS VRC MODULAR OFFICES FENCES 4.44 COP ?36 CORRECT/014 LTR#. PH-OV-16 161 ATLANTIC STREET • POMONA • CA 91768 • TEL : 909-869-0989 • FAX : 909-869-0981 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 2 TC 7/22/2014 TABLE OF CONTENTS DESCRIPTION PAGE TITLE PAGE 1 TABLE OF CONTENTS 2 MADIX STORAGE RACK (TYPE H2) 3 TO 15 WIRE WELD LIGHT DUTY FIXTURE (TYPE A) 16 TO 27 MEG LIGHT DUTY FIXTURE (TYPE E) 28 TO 39 GONDOLA (TYPE L) 40 TO 51 HYPERMAXI WIDE SPAN (TYPE X) 52 TO 56 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 3 TC 7/22/2014 Storage Racks - Stockroom Project Scope: The purpose of this analysis is to show that the following light duty storage fixtures complies with the specifications set forth in Section 2209 of the 2012 IBC and Section 15.5.3 of ASCE 7-10 . The storage racks are prefabricated and are to be field installed only without any field welding. Project Parameters: The fixtures will be analyzed as a braced steel storage rack system. The system will be analyzed for seismic loading utilizing the following equation: V = Cs x Ws Cs= Spsxl/R Sim = 2/3 x Fa x Ss 1= 1 R = 4 Seismic Factors: Project Specifications: Configurations: Fa = 1.00 Ss = 1.44 Steel - Shaped steel & rods, ASTM A570 Grade 55, Fy = 55,000 PSI All others, ASTM A36, Grade 36, Fy = 36,000 PSI Bolts - ASTM A307 unless otherwise noted Anchors - 3/8" 0 x 2-1/2" min. embedment Powers Wedge -Bolts+ (ICC ESR-2526) Slab - 5" x 2,500 PSI Soil - 1,500 PSF Type H2 144"H x 96"W x 48"D (5 levels) SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 4 TC 7/22/2014 Loads & Distribution: Fa = 1 Ss = 1.44 Sps= 2/3*Fa*Ss = 0.96 1= 1 R = 4 Cs= Sps* I/R = 0.240 # of Shelf #1= 1 Product Load/Level, wPL = 600 LB # of Shelves #2 = 4 Product Load/Level, wPL = 200 LB Dead Load/Level, wDL = 50 LB Total wPL = 1,400 LB Total wDL = 250 LB Ws = E(0.67*wPL+wDL) = 1,188 LB Vtotal = Cs*Ws = 0.24 x 1188 LB = 285 LB Transverse: <__= ASSUMED SITE CLASS D <=== SEISMIC DESIGN CATEGORY D <=== IN AREA NOT OPEN TO THE PUBLIC Depth = 48.0 IN Vtop = Cs*Ws,top = 0.24 x 450 LB = 108 LB Level wx hx wx hx Fi Movt 1 2 3 4 5 650 LB 250 LB 250 LB 250 LB 250 LB 5.1 IN 59.1 IN 75.1 IN 91.1 IN 107.1 IN 3,331 IN -LB 14,781 IN -LB 18,781 IN -LB 22,781 IN -LB 26,781 IN -LB 11.0 LB 48.7 LB 61.9 LB 75.1 LB 88.3 LB 56 IN -LB 2,882 IN -LB 4,653 IN -LB 6,846 IN -LB 9,461 IN -LB 1,650 LB TOTAL = Longitudinal: 86,456 IN -LB 285 LB 23,899 IN -LB Level wx hx wx hx Fi Movt 1 2 3 4 5 50 LB 50 LB 50 LB 50 LB 250 LB 5.1 IN 59.1 IN 75.1 IN 91.1 IN 107.1 IN 256 IN -LB 2,956 IN -LB 3,756 IN -LB 4,556 IN -LB 26,781 IN -LB 0.7 LB 8.3 LB 10.6 LB 12.8 LB 75.5 LB 1 IN -LB 17 IN -LB 32 IN -LB 51 IN -LB 378 IN -LB 450 LB TOTAL = 38,306 IN -LB 108 LB 478 IN -LB SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 5 TC 7/22/2014 Longitudinal & Transverse Analysis: to be pinned Longitudinal Column Forces: <== Based Assumed Mbase = 0 IN -LB Level Pcol-static Pcol-seismic Pcol-total Mcol Mconn-seismic Mconn-total 1 2 3 4 5 825 LB 500 LB 375 LB 250 LB 125 LB 0 LB 0 LB 0 LB 0 LB 0 LB 825 LB 500 LB 375 LB 250 LB 125 LB 731 IN -LB 3,701 IN -LB 902 IN -LB 654 IN -LB 353 IN -LB 2,216 IN -LB 2,301 IN -LB 778 IN -LB 504 IN -LB 177 IN -LB 2,865 IN -LB 4,146 IN -LB 1,427 IN -LB 1,153 IN -LB 826 IN -LB Transverse Loads: Level Pcol-static Pcol-seismic Pcol-total Mcol Mconn-seismic Mconn-total 1 2 3 4 5 825 LB 500 LB 375 LB 250 LB 125 LB 498 LB 497 LB 437 LB 340 LB 197 LB 1,323 LB 997 LB 812 LB 590 LB 322 LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB 0 IN -LB SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 6 TC 7/22/2014 Longitudinal Column Analysis: Single C 3 x 15/8 x 13ga. Analyzed per AISI and RMI ASD. Section properties are based P=(1+0.11SDs)DL+0.75*(1+0.14SDs)PL = 734 LB M= 0.75*0.7*Mcol = 1,943 IN -LB KxLx/rx = 1.7*54 IN/1.1991 IN = 76.6 <=== (KI/r)max KyLy/ry = 1*44 IN/0.6681 IN 65.9 ro= (rx^2 + ry^2 + xo^2)^0.5 = 2.036 IN 13= 1-(xo/ro)^2 (EQ. C4.2-3) = 0.455 Fe IS TAKEN AS THE SMALLER OF Fel AND Fe2: Fe1= rt^2E/(KL/r)max"2 (EQ C4.1-1) = 49.7 KSI sex= rt^2E/(KxLx/rx)^2 (EQ C3.1.2-7) = 49.7 KSI ot= 1/Aro^2[GJ+(rt^2ECw)/(KtLt)"2] (EQ C3.1.2-9) = 60.35 KSI Fe2= 1/(213)*{(hex+at)-[(aex+at)^2-(4*f3*aex*att)]^0.5} = 31.3 KSI Fe= 31.3 KSI Fy/2= 27.5 KSI SINCE, Fe > Fy/2 THEN, Fn= Fy(1-Fy/4Fe) (EQ. C4-3) = 30.8 KSI Pn= Aeff*Fn (EQ C4-2) = 15,437 LB Qc= 1.92 Pa= Pn/f)c = 8,040 LB P/Pa= 0.09 < 0.15 THUS, CHECK: P/Pa + Mx/Max <_ 1.0 (EQ C4-1) (EQ C5-3) Pno= Ae*Fy = 27,536 LB Pao= Pno/Oc = 14,342 LB Me= Cb*ro*Aeff*(sey*st)^0.5 = 65 IN-K My= Sx*Fy = 26,393 IN -LB Mc= My[1-My/(4Me)] = 23,709 IN -LB Max=Maxo= Mc/Of = 14,197 IN -LB µx= {1/[1-(Qc*P/Pcr)]}^-1 = 0.94 (734 LB/8040 LB) + (1943 IN-LB/14197 IN -LB) = on net effective sections. A (EQ C4.1-1) SECTION PROPERTIES A= 3.000 IN B= 1.625 IN C= 0.750 IN t = 0.090 IN Aeff = 0.501 IN^2 Ix = 0.720 INA4 Sx = 0.480 IN"3 rx = 1.199 IN ly = 0.224 IN"4 Sy = 0.254 INA3 ry = 0.668 IN J = 0.002 IN^4 Cw = 0.699 INA6 xo = 1.504 IN Kx = 1.7 Lx = 54.0 IN Ky = 1.00 Ly = 44.0 I N Kt = 1.00 Lt = 44.0 IN Fy= 55 KSI G= 11,300 E= 29,500 KSI Cmx= 0.85 Cb= 1.0 Of= 1.67 0.19 < 1.0, OK (EQ C5-3) SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 7 TC 7/22/2014 Transverse Column Analysis: Single C 3 x 15/8 x 13ga. Analyzed per AISI and RMI ASD. Section properties are based on net effective sections. P=(1+0.11SDs)DL+0.75*(1+0.14Sps)PL+0.75*0.7*EL = 932 LB KxLx/rx = 1.7*54 IN/1.1991 IN = 76.6 Kyly/ry = 1*44 IN/0.6681 IN 65.9 (KL/r)max = 76.6 ro= (rx^2 + ry^2 + xo^2)^0.5 = 2.036 IN f3= 1-(xo/ro)^2 = 0.455 (EQ. C4.2-3) Fe IS TAKEN AS THE SMALLER OF Fel AND Fe2: Fe1= rt"2E/(KL/r)max^2 (EQ C4.1-1) = 49.7 KSI A hex= rt^2E/(KxLx/rx)"2 (EQ C3.1.2-7) = 49.7 KSI ot= 1/Aro^2[GJ+(rt^2ECw)/(KtLt)^2] (EQ C3.1.2-9) = 60.35 KSI Fe2= 1/(2f3)*{(hex+6t)-[(tsex+ct)"2-(4*13*hex*at)]"0.5} (EQ C4.1-1) = 31.3 KSI Fe= 31.3 KSI Fy/2= 27.5 KSI SINCE, Fe > Fy/2 THEN, Fn= Fy(1-Fy/4Fe) = 30.8 KSI Pn= Aeff*Fn = 15,437 LB Qc= 1.92 Pa= Pn/Qc = 8,040 LB Pcol/Pa= 0.12 < 1.0, OK (EQ. C4-3) (EQ C4-2) (EQ C4-1) SECTION PROPERTIES A= 3.000 IN B= 1.625 IN C= 0.750 IN t = 0.0901N Aeff = 0.501 IN^2 Ix = 0.720 INA4 Sx = 0.480 INA3 rx = 1.199 IN ly = 0.224 INA4 Sy = 0.254 INA3 ry = 0.668 IN J = 0.002 INA4 Cw = 0.699 INA6 xo = 1.504 IN Kx = 1.7 Lx = 54.00 IN Ky = 1.00 Ly = 44.00 IN Kt = 1.00 Lt = 44.00 IN Fy= 55 KSI G = 11,300 E= 29,500 KSI INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 8 TC 7/22/2014 Beam Analysis Beam to column connections provide adequate moment capacity to stabalize the system, although it does not provide full fixity. Thus, the beams shall be analyzed assuming partial end fixity. In justifying the beam to column moment connection, the partial end fixity moment will be added to the Longitudinal frame moment for the analysis of the connection. END FIXITY = 25 Effective Moment for Partially Fixed Beam For simply supported beams, the max imum moment at the center is given by wL^2/8. An assumption of partial fixity will decrease the maximum moment by the following method. Q = 0.25 Mcenter = Mcenter(simple ends) - Q *Mcenter(fixed ends) = wL^2/8 - (0.25 * wL^2/12) wLA2/8 - wLA2/48 0.104 * wL^2 Reduction COEFF (i = 0.104/0.125 = 0.832 THUS, Mcenter = 8*(wL^2/8) = 0.832*(wL^/8) Mends = O*Mmax(fixed ends) = (wLA2/12)*0.25 = 0.0208*w02 Efective Deflection for Partially Fixed Beam Mcenter(simple) Mends (fixed) ---------------------- L 'max TYPICAL BEAM FRONT VIEW TYPICAL BEAM FRONT VIEW Mcenter (fixed) For simply supported beam conditions, the maximum deflection at the center is given by 5wL14/384E1. An assumption of partial fixity will decrease this maximum deflection by the following method: Dmax= [5w(L)^4/(384*E*Ix)] INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 9 TC 7/22/2014 Beam Analysis cont. Live Load = 600 LB Beam Dead Load = 50 LB End fixity = 25 % Mcenter = 0.104 * wL^2 = 3,245 IN -LB Mends = 0.0208*wLA2 = 649 IN -LB Lmax = [1950+1200(M1/M2)]b/Fy M1/M2 = 0.2 <=== SINCE Mcenter > Mends Lmax = (1950 + 240)*2.5/55 = 99.5 IN > L Thus, Fb = 0.6 * Fy = 33,000 PSI Maximum Static Load per Level depends on: 1) Moment Capacity If, fb = M/Sx. Then, 0.6 * Fy = (8*wL^2/8)/Sx Thus, Max Wt./Level = [9.6*Fy*Sx/(R * L)]*a = (9.6* 55 KSI * 0.893 IN^3)/(0.832*96 IN)*0.875 = 5,247 LB/LVL <=== GOVERNS OR, 2) Allowable Deflection If, Dallow = L/180 = 0.533 IN And, D = [5w(L)^4/(384*E*Ix)]*R Then, Max Wt./Level = 2*[(384*E*Ix*Hallow)/(5*L^3 * R)] = 6,067 LB/LVL Thus, Maximum Allowable Live Load / Level = 5,197 LB/LVL LEVEL Mstatic Mimpact 1 3,245 IN -LB 3,708 IN -LB 2 1,997 IN -LB 2,282 IN -LB 3 3,245 IN -LB 3,708 IN -LB 4 3,245 IN -LB 3,708 IN -LB 5 3,245 IN -LB 3,708 IN -LB Mallow(static) 29,469 IN -LB 29,469 IN -LB 29,469 IN -LB 29,469 IN -LB 29,469 IN -LB Beam Properties Ix = 1.880 IN^4 Sx = 0.893 IN^3 Fy = 55,000 PSI Length=L = 96.0 IN a = 4.000 IN b = 2.500 IN c = 1.750 IN d = 0.750 IN e = 1.500 IN t = 0.075 IN a = Impact Coefficient = 0.875 (3 = 0.832 Mseismic 2,865 IN -LB 4,146 IN -LB 1,427 IN -LB 1,153 IN -LB 826 IN -LB Mseismic(allow) 39,292 IN -LB 39,292 IN -LB 39,292 IN -LB 39,292 IN -LB 39,292 IN -LB Result Good Good Good Good Good SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT BUY BUY BABY #3098 FOR BED BATH & BEYOND SHEET NO. 10 CALCULATED BY TC DATE 7/22/2014 Beam to Column Connection Analysis Mconn = 0.75*0.7*Mconn. seismic + Mend 2,153 IN -LB Connection capacity depends on the following parameters: 1) Shear capacity of the studs STUD DIAMETER= 7/16 IN Fy= 55,000 PSI Pmax-shear= 0.4 * Fy * Area = 0.4 * 55000 PSI * (0.4375 IN)^2 * rt/4 = 3,307.3 LB 2) Bearing capacity on column Fu= 65,000 PSI Pmax-brg= Bearing Area * Fbearing = (tmin * thickness) * (1.2 * Fu) = (0.4375 IN * 0.09 IN) * (1.2 *65000 PSI) = 3,071.3 LB < 3307.3 LB 3) Moment capacity of bracket Mcap= Sbracket * Fbending =0.1IN^3*0.66*Fy = 3,630 IN -LB C= Mcap/0.75 = 1.67 * P1 THUS, P1= 0.798 * Mcap = 2,897 IN -LB < 3307.3 LB THUS, GOVERNING VALUE IS THE MIN VALUE OF P1, P1-eff= 2,897 LB Mconn-allow= P1*4.5 IN + P2*2.5 IN + P3*0.5 IN = 5.94 * P1-eff = 17,207 IN -LB > Mconn max, OK 311 ,If— 1-5/8" 4 C= P1+P2+P3 = P1+P1*(2.5/4.5)+P1*(0.5/4.5) = 1.67*P1 Sbracket= 0.100IN^3 1/2" 1/2„ SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 11 TC 7/22/2014 Transverse Brace Analysis It is assumed that the transverse braces resist the seismic shear in tension and compression, with compression being critical in the design. Diagonal Member 0.75*0.7*Vtran= 150 LB Ldiag= [(D-3")^2 + (H-6")^2]^(1/2) = 58.9 IN Pmax= V*(Ldiag/D) = 183.7 LB (kl/r)max= (k * Ldiag)/r min = 1 x 58.9 IN /0.422 IN ) = 139.6 IN Fe= rt`E/(kl/r)` = 14,693 PSI SINCE Fe<Fy/2, Fn= Fe = 14,693 PSI Pn= AREA*Fn = 0.212IN^2 * 14693 PSI = 3,115 LB Qc= 1.92 Pallow= Pn/Oc = 3115 LB /1.92 = 1,622 LB h D LOWER BRACE PANEL ELEVATION H= 44.0 IN D= 48.0 IN Horizontal Member 1 1/4" 0 x 16ga. t = 0.060 IN AREA= 0.212 IN^2 r min= 0.422 IN Fy= 55,000 PSI Diagonal Member fa/Fa= 0.11 < 1.0 OK 1 1/4" 0 x 16ga. Horizontal Member t = 0.060 IN Similarly for horizontal members. AREA= 0.212 IN^2 r min= 0.422 IN Pmax= 149.7 LB Fy= 55,000 PSI fa/Fa= 0.04 < 1.0 OK SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 12 TC 7/22/2014 Overturning Analysis Fully Loaded: Movt = 23,899 IN -LB Mpg = 250 LB x 48 IN / 2 = 6,000 IN -LB MPLapp = 0.67*1400 LB X 48 IN / 2 = 22,512 IN -LB Vcol = 0.7*Vtotal = 200 LB d = 48.00 IN Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors / Plate = 2 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11SDs) x MDL - 0.75 x (0.6-0.14SDs) x MPLapp] / d = [0.75*0.7*23899 - (0.6-0.11*0.24)*6000 - 0.75*(0.6-0.14*0.24)*22512] IN -LB / 48 IN = -10 LB <=== NO UPLIFT Interaction Equation [0 LB/ 740 LB] + [100 LB/ 1080 LB] = Top shelf loaded only: Movt = 478 IN -LB MDL = 6,000 IN -LB MPLapp = 200 LB x 48 IN / 2 = 4,800 IN -LB Vcol = 0.7*Vtop = 76 LB 0.09 < 1.2 Therefore OK d = 48.0 I N Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors per Plate = 2 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11S0s) x MDL - 0.75 x (0.6-0.14SDs) x MPLapp] / d = [0.75*0.7*478 - (0.6-0.11*0.24)*6000 - 0.75*(0.6-0.14*0.24)*4800] IN -LB / 48 IN = -109 LB <=== NO UPLIFT INTERACTION EQN. [0 LB/ 370 LB] + [38 LB/ 540 LB] = 0.04 < 1.2 Therefore OK rulisrZZZIIIIIIIII INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 13 TC 7/22/2014 Base Plate Analysis Pcol = Pstatic + Mot/D = 932 LB Effective Base Width = 7.00 IN Effective Base Depth = 5.00 IN b = 3.00 IN b1= 2.00 IN Thickness (t) = 0.375 IN Fy = 36,000 PSI fa =P/A = Pcol/(D x B) = 26.64 PSI Mbase = (W)(L12)/2 = (fa)(b1^2)/2 = 53 IN.LB. Sbase=(1)(t^2)/6 = 0.0234 IN^3 Fbase = 0.75 x Fy = 27,000 PSI fb/Fb = Mbase/((Sbase)(Fbase)) = 0.08 < 1.0 OK INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 14 TC 7/22/2014 LRFD Load Combination - For Slab and Soil Analysis Load combination per RMI 2.2 Resultant Load combination 1 1.4DL + 1.2PL 1.4DL + 1.2PL 2 1.2DL + 1.6PL + 1.6LL + 0.5(Lr or SL or RL) 1.2DL + 1.6PL 3 1.2DL + 0.85PL + (0.5LL or 0.8WL) + 1.6(Lr or SL or RL) 1.2DL + 0.85PL 4 1.2DL + 0.85PL + 0.5LL + 1.6WL + 0.5(Lr or SI or RL) 1.2DL + 0.85PL 5 (1.2+0.2SD5)DL + (0.85+0.2SD5)PL + 0.5LL + EL + 0.2SL (1.2+0.2SD5)DL + (0.85+0.2SD5)PL + EL 6 (0.9-0.2SD5)DL + (0.9-0.2SD5)PLapp - EL (0.9-0.2SD5)DL + (0.9-0.2SD5)PLapp - EL DL-total/col = 125 LB PL-total/col = 700 LB E = 498 LB Load combination 1 Pmax = 1.4DL + 1.2PL = 1.4 x 125 LB + 1.2 x 700 LB = 1,015 LB Load combination 2 Pmax = 1.2DL + 1.6PL = 1.2 x 125 LB + 1.6 x 700 LB = 1,270 LB Load combination 3 & 4 Pmax = 1.2DL + 0.85PL = 1.2 x 125 LB + 0.85 x 700 LB = 745 LB Load combination 5 Pmax = (1.2+0.2SD5)DL + (0.85+0.2SD5)PL + EL = (1.2+0.2*0.24) x 125 LB + (0.85+0.2*0.24) x 700 LB + 1.0 x 498 LB = 1,283 LB Load combination 6 Pmax = (0.9-0.2SD5)DL + (0.9-0.2SD5)PLapp - EL _ (0.9-0.2*0.24) x 125 LB + (0.9-0.2*0.24) x 469 LB - 498 LB _ -107 LB SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 15 TC 7/22/2014 Slab & Soil Analysis The slab will be checked for puncture and bearing stress. If no puncture occurs, the slab is assumed to distribute the load over a larger area of the slab. Pmax = 1,283 LB a) Puncture: Fpunct = 2.66 x (F'c^0.5) = 2.66 x (2500 PSI)^0.5 = 133 PSI Apunct = [(Weff.+t/2)+(Deff.+t/2)] x 2 x t = [(7 1N + 5IN/2) + (5 IN + 5IN/2)] x 2 x 5IN = 170 INA2 fv/Fv = P/[(Apunct)(Fpunct)] = 1283 LB/[170 IN^2 x 133 PSI x 0.55] b) Bearing: 0Bn=0.85x0xf'cxAl = 40,906 LB Pu / 0Bn = 1283 LB / 40906 LB c) Slab Tension Asoil = P/[1.0 x fs] = 1283 LB/[1.0 x 1500 PSF/(144IN^2/FT^2)] = 123 IN^2 L = Asoil^0.5 = (123.13 IN^2)^0.5 = 11.1 IN B = [(Weff.)(Deff.)]^0.5 + t _ [7 IN x 5 IN]^0.5 + 5 = 11.0 IN b = (L-B)/2 = (11.1 IN - 10.99 IN)/2 _ .1 1N Mconc = (w)(b^2)/2 = [(1.0)(fs)(b^2)]/[144 (IN^2/FT^2) x 2] = [1.0 x 1500 PSI x (0.05 IN)^2]/[144 (INA2/FTA2) x 2] = 0 IN -LB Sconc = 1 IN x (t^2)/6 = 1 IN x (5 IN)^2/6 = 4.17 IN^3 Fconc = 5 x 0 x fc^0.5 = 5 x 0.55 x (2500 PSI)^0.5 = 137.5 PSI fb/Fb = Mconc/[(Sconc)(Fconc)] = 0.01 IN-LB/[(4.17 INA3)(137.5 PSI)] 0.10 < 1.0 OK 0.03 < 1.0 OK Base Plate: W = 7.00 IN D = 5.00 IN Al = 35.0 IN^2 Concrete: Thickness = 5.00 IN f'c = 2,500 PSI Soil: fs = 1,500 PSF 0= 0.55 0.00 < 1.0 OK r SEIZMIC 1 INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 16 TC 7/22/2014 Wire Weld Light Duty Storage Fixtures - Sales Floor Project Scope: The purpose of this analysis is to show that the following light duty storage fixtures complies with the specifications set forth in the 2012IBC . The light duty storage fixtures are prefabricated and are to be field installed only without any field welding. Project Parameters: The Wire Weld fixtures consists of several bays, interconnected in one or both directions with columns of the vertical frames being common between any adjacent bays. Stability longitudinally is depedent on the x-braces, while the wire weld panels act transversely. The analysis will focus on a tributary bay to be analyzed in both the longitudinal & transverse direction. The Wire Weld fixtures are fully braced, and will be analyzed as a braced steel storage rack system. The system will be analyzed for seismic loading utilizing the following equation: V = Cs x Ws Cs= SD, xI/R SDS = (2/3) x Fa x Ss I = 1.5 R = 4 Seismic Factors: Project Specifications: Configurations: Fa = 1.00 Ss = 1.44 Steel - Shaped steel & Rods, ASTM A500 Grade 50, Fy = 50,000 psi All others, ASTM A36, Grade 36, Fy = 36,000 psi Bolts - ASTM A307 unless otherwisw noted Anchors - 3/8" 0 x 2-1/2" min. embedment Powers Wedge -Bolts+ (ICC ESR-2526) Slab - 5" x 2,500 psi Soil - 1,500 psf Type A, A3 Type A2, A5 Type Al, A6 Type A21 147"H x (48"/36")W x 25-1/2"D 147"H x (48"/36")W x 19-1/2"D 147"H x (48"/36")W x 13-1/2"D 96"H x 48"W x 25-1/2"D Only the critical configurations to be analyzed <=== critical <=== critical <=== critical PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 17 TC 7/22/2014 SEIZMIC ■ INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 1) ANCHOR 2) FOOT PLATE 3) POST 4) LONGITUDINAL X-BRACES 5) SHELVES 6) TRANSVERSE X-BRACES SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 18 TC 7/22/2014 Summary & Elevation: TYPE: A, A3 (2) Bracing req'd @ every 3 bay I 1r 12" 12" • FRONT VIEW 3 Storage Capacity - 48 LB/LVL 1' 251 /2"-4 SIDE VIEW 3' Post Base Plate Stress = 0.48 Ok Overturning Stress -full = 0.79 Stress -top = 0.23 Ok Stress(L) = 0.49 Stress(T) = 0.10 Ok Bracing Stress(L) = 0.60 Stress(T) = 0.02 Ok Slab & Soil Stress = 0.20 Stress = 0.04 r SEIZMIC 1 INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 19 TC 7/22/2014 Summary & Elevation: TYPE: A2, A5 1C0" (2) Bracing req'd @ every 3 bay W -- 12" 12" 11 } FRONT VIEW 3" Storage Capacity - 36 LB/LVL "`— 19 1/2" —f SIDE VIEW 3" Post Stress = 0.44 Ok Overturning Stress -full = 0.84 Stress -top = 0.28 Ok Base Plate Stress(L) = 0.38 Stress(T) = 0.09 Ok Bracing Stress(L) = 0.47 Stress(T) = 0.02 Ok Slab Stress = 0.19 Stress = 0.03 llisaul SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 20 TC 7/22/2014 Summary & Elevation: TYPE: Al, A6 r-- w 100" �y (2) Bracing req'd @ every 3 bay FRONT 4ELV 147" Storage Capacity - 24 LB/LVL 13 1/2" —% 12' f2 3' 3' SIDE VIEW Post Stress = 0.40 Ok Overturning Stress -full = 0.91 Stress -top = 0.35 Ok Base Plate Stress(L) = 0.27 Stress(T) = 0.08 Ok Bracing Stress(L) = 0.34 Stress(T) = 0.01 Ok Slab Stress = 0.18 Stress = 0.03 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 21 TC 7/22/2014 Loads & Distribition - 25-1/2" Deep Fa = 1.00 Ss = 1.44 SDs = 2/3 * Fa * Ss = 0.960 1= 1.5 R = 4 Cs=SDs*I/R = 0.360 wPL, Product Load/Level = 48.0 LB wDL, Dead Load/Level = 5.0 LB # of Shelf Levels = 13 Ws = E(0.67*wPL+wDL) = 483 LB Vtotal = Cs*Ws = 0.36 x 483 LB = 174 LB Fully loaded: <__= ASSUMED SITE CLASS D <=== SEISMIC DESIGN CATEGORY D <=== IN AREA OPEN TO THE PUBLIC Depth = 25.5 IN Occurrence of Brace = 1.5 Vtop = Cs*Ws,top = 0.36 x 113 LB = 41 LB Level wx hx wx hx Fi Movt 1 2 3 4 5 6 7 8 9 10 11 12 13 53 LB 53 LB 53 LB 53 LB 53 LB 53 LB 53 LB 53 LB 53 LB 53 LB 53 LB 53 LB 5 LB 3.000 IN 15.00 IN 27.00 IN 39.00 IN 51.00 IN 63.00 IN 75.00 IN 87.00 IN 99.00 IN 111.0 IN 123.0 IN 135.0 IN 147.0 IN 159 IN -LB 795 IN -LB 1,431 IN -LB 2,067 IN -LB 2,703 IN -LB 3,339 IN -LB 3,975 IN -LB 4,611 IN -LB 5,247 IN -LB 5,883 IN -LB 6,519 IN -LB 7,155 IN -LB 735 IN -LB 0.6 LB 3.1 LB 5.6 LB 8.1 LB 10.5 LB 13.0 LB 15.5 LB 18.0 LB 20.4 LB 22.9 LB 25.4 LB 27.9 LB 2.9 LB 2 IN -LB 46 IN -LB 151 IN -LB 314 IN -LB 537 IN -LB 820 IN -LB 1,162 IN -LB 1,563 IN -LB 2,024 IN -LB 2,545 IN -LB 3,125 IN -LB 3,764 IN -LB 421 IN -LB 641 LB Total = Top shelf loaded only: 44,619 IN -LB 174 LB 16,474 IN -LB Level wx hx wx hx Fi Movt 1 2 3 4 5 6 7 8 9 10 11 12 13 5 LB 5 LB 5 LB 5 LB 5 LB 5 LB 5 LB 5 LB 5 LB 5 LB 5 LB 53 LB 5 LB 3.000 IN 15.00 IN 27.00 IN 39.00 IN 51.00 IN 63.00 IN 75.00 IN 87.00 IN 99.00 IN 111.0 IN 123.0 IN 135.0 IN 147.0 IN 15 IN -LB 75 IN -LB 135 IN -LB 195 IN -LB 255 IN -LB 315 IN -LB 375 IN -LB 435 IN -LB 495 IN -LB 555 IN -LB 615 IN -LB 7,155 IN -LB 735 IN -LB 0.05 LB 0.27 LB 0.48 LB 0.70 LB 0.91 LB 1.13 LB 1.34 LB 1.56 LB 1.77 LB 1.99 LB 2.20 LB 25.63 LB 2.63 LB 0 IN -LB 4 IN -LB 13 IN -LB 27 IN -LB 47 IN -LB 71 IN -LB 101 IN -LB 136 IN -LB 176 IN -LB 221 IN -LB 271 IN -LB 3,460 IN -LB 387 IN -LB 113 LB Total = 11,355 IN -LB 41 LB 4,913 IN -LB SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 22 TC 7/22/2014 Column Analysis P=(1+0.11Sps)DL+0.75*(1+0.14SDs)PL+0.75*0.7E =(1+0.11*0.96)*(5*13)/2+0.75*(1+0.14*0.96)*(48*12)/2+0.75*0.7*(16474/25.5) = 620 LB KxLx/rx = 1*12 IN/0.398 IN = 30.2 KyLy/ry = 1 * 12 IN/0.095 IN = 126.3 (KL/r)max = 126.3 ro= (rx^2 + ry^2 + xo^2)^0.5 = 0.448 IN 8= 1-(xo/ro)^2 = 0.833 Fe IS TAKEN AS THE SMALLER OF Fel AND Fe2: (EQ. C4.2-3) Fe1= rt^2E/(KL/r)max^2 (EQ C4.1-1) = 18.2 KSI oex= rt^2E/(KxLx/rx)^2 = 320.3 KSI ot= 1/Aro^2[GJ+(T(^2ECw)/(KtLt)^2] = 112.66 KSI Fe2= 1/(28)*{(oex+ot)-[(oex+ot)^2-(4*g*oex*ot)]^0.5} = 104.3 KSI Fe= 18.2 KSI Fy/2= 25.0 KSI SINCE, Fe < Fy/2 THEN, Fn= Fe = 18.2 KSI Pn= Aeff*Fn = 2,476 LB Oc= 1.92 Pa= Pn/Qc = 1,289 LB Pcol/Pa= 0.48 < 1.0, Ok 11116 \ 16 GA. 1.'r 0' ''1 14 114 1► 1 5/8 +� SECTION PROPERTIES (EQ C3.1.2-7) t = 0.060 IN Aeff = 0.136 IN^2 (EQ C3.1.2-9) Ix = 0.022 INA4 Sx = 0.033 IN^3 (EQ C4.1-1) rx = 0.398 IN ly = 0.001 IN^4 Sy = 0.005 IN^3 ry = 0.095 1N J = 0.000 IN^4 Cw = 0.001 IN^6 (EQ. C4-4) xo = -0.183 IN Kx = 1.0 Lx = 12.00 I N (EQ C4-2) Ky = 1.00 Ly = 12.00 I N Kt = 1.0 Lt = 12.00 IN Fy = 50 KSI (EQ C4-1) G = 11,300 E = 29,500 KSI SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 23 TC 7/22/2014 Brace Analysis Bracing capacity is governed by tension capacity of cross bracing. Pbrace = Vtotal x Brace Occurrence = 261 LB Longitudinal Bracing: Veff = 0.75*0.7*Pbrace = 137 LB Vdiag = Veff x (Ldiag/Lhoriz) = 137LBx111IN/48IN = 316 LB <==Seismic Load in Tension Tension Capacity of the Turn Buckle Tallow = 0.6 x Fy x Area = 0.6 x 50000 PSI x 0.018 IN^2 = 530 LB Vdiag/Tallow = 0.60 < 1.0, Ok Transverse Bracing: Veff = 0.75*0.7*Pbrace = 72 LB Vdiag = Veff x (Ldiag/Lhoriz) = 72 LB x 381N/ 24 IN = 115 LB <==Seismic Load in Tension Tension Capacity of the Rod Tallow = 0.6 x Fy x Area = 0.6 x 50000 PSI x 0.1963 IN^2 = 5,890 LB > Vdiag OK IN TENSION Vdiag/Tallow = 0.02 < 1.0, Ok Cross Brace Member Turn Buckle 0 = 0.150 IN Area (turn buckle) = 0.018 IN^2 Lhoriz=D = 48.00 IN Lvert=h = 100.0 IN Ldiag = 110.9 IN Fy = 50,000 PSI Cross Brace Member Rod 0 = 0.500 IN Area (rod) = 0.196 IN^2 Lhoriz=D = 24.00 IN Lvert=h = 30.00 IN Ldiag = 38.42 IN Fy = 50,000 PSI SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT BUY BUY BABY #3098 FOR BED BATH & BEYOND SHEET NO. 24 CALCULATED BY DATE TC 7/22/2014 Overturning/Anchorage Analysis Fully loaded: Movt = 16,474 IN -LB MDL = 5 LB x 13 Levels x 25.5 IN / 2 = 829 IN -LB MpLaPP = 0.67*48 LB x 13 Levels x 25.5 IN / 2 = 5,331 IN -LB Vcol = 0.7*Vtotal/2 = 61 LB d = 25.5 IN Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors/Plate = 1 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11SD5) x MDL - 0.75 x (0.6-0.14SDS) x MpLapp] / d = [0.75*0.7*16474 - (0.6-0.11*0.96)*829 - 0.75*(0.6-0.14*0.96)*5331] IN -LB / 25.5 IN = 250 LB <=== UPLIFT Interaction Equation [250 LB/ 370 LB] + [61 LB/ 540 LB] = Top shelf loaded only: Movt = 4,913 IN -LB MDR = 5 LB x 13 Levels x 25.5 IN / 2 = 829 IN -LB MPLapp = 48 LB x 25.5 IN / 2 = 612 IN -LB Vcol = 0.7*Vtop/2 = 14 LB 0.79 < 1.2 Therefore OK d = 25.5 IN Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors/Plate = 1 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11SDs) x MDL - 0.75 x (0.6-0.14SDs) x MpLapp] / d = [0.75*0.7*4913 - (0.6-0.11*0.96)*829 - 0.75*(0.6-0.14*0.96)*612] IN -LB / 25.5 IN = 77 LB <=== UPLIFT INTERACTION EQN. [77 LB/ 370 LB] + [14 LB/ 540 LB] = 0.23 < 1.2 Therefore OK Anchors - 3/8" 0 x 2-1/2" min. embedment Powers Wedge -Bolts+ (ICC ESR-2526) r SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 25 TC 7/22/2014 Base Plate Analysis Longitudinal Check: P = Pcol-static = 345 LB fa = P/A = Pcol/[(Deff.)(Beff.)] = 79 PSI Mlbase/in = (W/in)(L^2)/2 = (fa)(b1^2)/2 = 35 IN -LB Sbase/in = (1)(t^2)/6 = 0.003 IN^3 Fbase = (0.75)(Fy) = 27,000 PSI fb/Fb = Mbase/in/((Sbase/in)(Fbase)) = 0.49 < 1.0, Ok fa Transverse Check: P = Pcol-static + Pcol-seismic = 620 LB fa = P/A = Pcol/[(Deff.)(Beff.)] = 142 PSI Mlbase/in = (W/in)(LA2)/2 = (fa)(b1^2)/2 = 7 IN -LB Sbase/in = (1)(t^2)/6 = 0.003 INA3 Fbase = (0.75)(Fy) = 27,000 PSI fb/Fb = Mbase/in/((Sbase/in)(Fbase)) = 0.10 < 1.0, Ok Base Steel Properties: b1— b Beff. = 3.50 IN Deff. = 1.25 IN b = 1.63 IN bl = 0.94 IN t = 0.125 1N Fy = 36,000 PSI B Base Steel Properties: Beff. = 1.25 IN Deff. = 3.50 IN b = 0.63 IN b1 = 0.31 IN t = 0.125 IN Fy = 36,000 PSI SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 26 TC 7/22/2014 LRFD Load Combination - For Slab and Soil Analysis Load combination per RMI 2.2 Resultant Load combination 1 1.4DL + 1.2PL 1.4DL + 1.2PL 2 1.2DL + 1.6PL + 1.6LL + 0.5(Lr or SL or RL) 1.2DL + 1.6PL 3 1.2DL + 0.85PL + (0.5LL or 0.8WL) + 1.6(Lr or SL or RL) 1.2DL + 0.85PL 4 1.2DL + 0.85PL + 0.5LL + 1.6WL + 0.5(Lr or SI or RL) 1.2DL + 0.85PL 5 (1.2+0.2SDs)DL + (0.85+0.2SD5)PL + 0.5LL + EL + 0.2SL (1.2+0.2Sp5)DL + (0.85+0.25Ds)PL + EL 6 (0.9-0.2SD5)DL+ (0.9-0.2SD5)PLapp - EL (0.9-0.2SD5)DL+ (0.9-0.2SDs)PLapp - EL DL-total/col = 33 LB PL-total/col = 312 LB EL = 646 LB Load combination 1 Pmax = 1.4DL + 1.2PL = 1.4 x 33 LB + 1.2 x 312 LB = 420 LB Load combination 2 Pmax = 1.2DL + 1.6PL = 1.2x33LB+1.6x312LB = 538 LB Load combination 3 & 4 Pmax = 1.2DL + 0.85PL =-1.2x33 LB+0.85x312 LB = 304 LB Load combination 5 Pmax = (1.2+0.2SD5)DL + (0.85+0.2SD5)PL + EL = (1.2+0.2*0.96) x 33 LB + (0.85+0.2*0.96) x 312 LB + 646 LB = 1,016 LB Load combination 6 Pmax = (0.9-0.2Sps)DL + (0.9-0.2SDs)PLapp - EL = (0.9-0.2*0.96) x 33 LB + (0.9-0.2*0.96) x 209 LB - 646 LB = -475 LB SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 27 TC 7/22/2014 Slab & Soil Check The slab will be checked for puncture and bearing. If puncture does not occur, it will be assumed that the load is being distributed over a larger area of the soil. Pmax = 1,016 LB a) Puncture: Fpunct = 2.66 x (F'c^0.5) = 2.66 x (2500 PSI)^0.5 = 133 PSI Apunct = [(Weff.+t/2)+(Deff.+t/2)] x 2 x t = [(3.5 IN + 5 IN/2) + (1.25 IN + 5 IN/2)] x 2 x 5 IN = 98 IN^2 fv/Fv = P/[(Apunct)(Fpunct)] = 1016 LB/[98 INA2 x 133 PSI x 0.55] = 0.14 < 1.0 Ok b) Bearing: 0Bn=0.85x0xf'cxAl = 5,113 LB Pu/0Bn= 1016 LB/5113 LB = 0.20 < 1.0 Ok c) Slab Tension: Asoil = P/[1.0 x fs] = 1016 LB/[1.0 x 1000 PSF/(1441N^2/FT^2)] = 146 IN^2 L= B= b= Mconc = Sconc = Fconc = fb/Fb = Asoil^0.5 (146.35 IN^2)^0.5 12.1 IN [(Weff.)(Deff.)]^0.5 + t [3.5 IN x 1.25 IN]^0.5 + 5 7.1 IN (L-B)/2 (12.1 IN - 7.09 IN)/2 2.5 IN (w)(b^2)/2 = [(1.0)(fs)(b^2)]/[144 (INA2/FTA2) x 2] [1.0 x 1000 PSF x (2.5 IN)^2]/[144 (IN^2/FT^2) x 2] 22 IN -LB 1 IN x (t^2)/6 1 IN x (5 IN)^2/6 4.17 IN^3 5x0xfc^0.5 5 x 0.55 x (2500 PSI)^0.5 137.5 PSI Mconc/[(Sconc)(Fconc)] 21.75 IN-LB/[(4.17 IN^3)(137.5 PSI)] 0.04 < 1.0 Ok Base Plate Weff. = 3.50 IN Deff. = 1.25 IN Al = 4.38 IN^2 Slab on Grade t = 5.00 I N f'c = 2,500 PSI 0= 0.55 Soil Fs = 1,000 PSF SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 28 TC 7/22/2014 Stockroom Light Duty Storage Racks Project Scope: The purpose of this analysis is to show that the following light duty storage fixtures complies with the specifications set forth in the 2012 International Building Code. The light duty storage fixtures are prefabricated and are to be field installed only without any field welding. Project Parameters: The fixtures will be analyzed as a braced steel storage rack system. This type of system will be located both on grade. The system will be analyzed for seismic loading utilizing the following equation: Seismic Factors: Project Specifications: Configurations: V = Cs x Ws Cs = Spsxl/R Sps = 2/3 x Fa x Ss 1= 1 R = 4 Fa = 1.00 Ss = 1.44 Steel - Shaped steel & Rods, ASTM A570 Grade 36, Fy = 36,000 psi All others, ASTM A36, Grade 36, Fy = 36,000 psi Bolts - A307 UNLESS OTHERWISE NOTED Anchors - 3/8" 0 x 2-1/2" min. embedment Powers Wedge Bolts (ICC ESR-2526) Slab - 5" x 2,500 psi Soil - 1,500 psf Type Ea 144"H x 48-1/2"W x 24-1/2"D (6 levels) Type Eb 144"H x 48-1/2"W x 24-1/2"D (11 levels) INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 29 TC 7/22/2014 General Configurations: 1) POST 2) FOOT PLATE 3) ANCHOR 5) SHELF SUPPORT BEAM 6) TIE PLATE 7) TIE SUPPORT I r 1 1 L J I NOTE: THIS IS THE TRIBUTARY SYSTEM BEING ANALYZED. I relli.1.171\111.111 INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 30 TC 7/22/2014 Summary & Elevations: Type Ea 1 Elevation: 144"H x 48-1/2"W x 24-1/2"D (6 levels) 4" 1-48 1 /2" � r-24 1/2"--1 22 /2" 22 22 /2" /2" 1 8" 551 /2" Storage Capacity - 175 LB/LVL 22 /2" 22 1 /2" 22 1 /2" 18" 28 1/2" 1 4" 2 1 /4" FRONT VIEW SIDE VIEW 2 1/4" Post ( Stress (T) = 0.49 Stress (L) = 0.74 Ok Overturning I Double Rivet Connection Slab & Soil Stress -full = 0.45 Stress -top = 0.18 Ok Stress = 0.82 Ok Stress = 0.16 Stress = 0.03 Ok SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 31 TC 7/22/2014 Summary & Elevations: Type Eb Elevation: 144"H x 48-1/2"W x 24-1/2"D (11 levels) Storage Capacity - 200 LB/LVL 1-48 1/2" 1-24 1 /2"--1 144" 161/2" 16 1/2" 16 1 /2" 161/2" 16 1 /2" 144" 2 1/4" FRONT VIEW SIDE VIEW 2 1 /4" Post 1 Stress (T) = 0.56 Stress (L) = 0.44 Ok Overturning 1 Double Rivet Connection Slab & Soil Stress -full = 0.81 Stress -top = 0.23 Ok_ Stress = 0.73 Ok Stress = 0.31 Stress = 0.15 Ok INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 32 TC 7/22/2014 Loads & Distribution: Type Ea Fa = 1.00 Ss = 1.44 Sps = 2/3*Fa*Ss = 0.96 1= 1 R = 4 Cs=Sps*I/R = 0.240 Product Load/Level, wPL = 175.0 LB Dead Load/Level, wDL = 10.00 LB # of Shelf Levels = 6 Ws = E(0.67*wPL+wDL) = 764 LB Vtotal = Cs*Ws = 0.24 x 764 LB = 183 LB Transverse: <__= ASSUMED SITE CLASS D <=== SEISMIC DESIGN CATEGORY D <=== IN AREA NOT OPEN TO THE PUBLIC Depth = 24.5 IN Vtop = Cs*Ws,top = 0.24 x 235 LB = 56 LB Level wx hx wx hx Fi Movt 1 2 3 4 5 6 7 185 LB 0 LB 185 LB 185 LB 185 LB 185 LB 185 LB 2.250 IN 30.75 IN 57.75 IN 75.75 IN 98.25 IN 120.8 IN 143.3 IN 416 IN -LB 0 IN -LB 10,684 IN -LB 14,014 IN -LB 18,176 IN -LB 22,339 IN -LB 26,501 IN -LB 0.83 LB 0.00 LB 21.26 LB 27.89 LB 36.17 LB 44.46 LB 52.74 LB 2 IN -LB 0 IN -LB 1,228 IN -LB 2,113 IN -LB 3,554 IN -LB 5,368 IN -LB 7,556 IN -LB 1,110 LB TOTAL = Longitudinal: 92,130 IN -LB 183 LB 19,821 IN -LB Level WX hx wx hx Fi Movt 1 2 3 4 5 6 185 LB 185 LB 185 LB 185 LB 185 LB 185 LB 2.250 IN 57.75 IN 75.75 IN 98.25 IN 120.8 IN 143.3 IN 416 IN -LB 10,684 IN -LB 14,014 IN -LB 18,176 IN -LB 22,339 IN -LB 26,501 IN -LB 0.83 LB 21.26 LB 27.89 LB 36.17 LB 44.46 LB 52.74 LB 2 IN -LB 1,228 IN -LB 2,113 IN -LB 3,554 IN -LB 5,368 IN -LB 7,556 IN -LB 1,110 LB TOTAL = 92,130 IN -LB 183 LB 19,821 IN -LB Eff. Levels 1 0 1 1 1 1 1 Eff. Levels 1 1 1 1 1 1 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 33 TC 7/22/2014 Longitudinal & Transverse Analysis: to be pinned Longitudinal Column Forces: <== Based Assumed Mbase = 0 IN -LB Level Pcol-static Pcol-seismic Pcol-total Mcol Mconn-seismic 1 2 3 4 5 6 555 LB 463 LB 370 LB 278 LB 185 LB 93 LB 0 LB 0 LB 0 LB 0 LB 0 LB 0 LB 555 LB 463 LB 370 LB 278 LB 185 LB 93 LB 206 IN -LB 2,533 IN -LB 726 IN -LB 750 IN -LB 547 IN -LB 297 IN -LB 1,369 IN -LB 1,629 IN -LB 738 IN -LB 649 IN -LB 422 IN -LB 148 IN -LB Transverse Loads: Level Pcol-static Pcol-seismic Pcol-total Mcol Mconn-seismic 1 2 3 4 5 6 7 555 LB 463 LB 463 LB 370 LB 278 LB 185 LB 648 LB 809 LB 809 LB 809 LB 759 LB 673 LB 528 LB 308 LB 1,364 LB 1,271 LB 1,271 LB 1,129 LB 950 LB 713 LB 956 LB 206 IN -LB 1,301 IN -LB 1,232 IN -LB 726 IN -LB 750 IN -LB 547 IN -LB 297 IN -LB 1,507 IN -LB 2,533 IN -LB 1,958 IN -LB 1,476 IN -LB 1,297 IN -LB 843 IN -LB 297 IN -LB INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT BUY BUY BABY #3098 FOR BED BATH & BEYOND SHEET NO. 34 CALCULATED BY DATE TC 7/22/2014 Transverse Post Analysis Analyzed per AISI. Section properties are based on net effective sections. P=(1+0.11SDs)DL+0.75*(1+0.14SDs)PL+0.75*0.7*EL = 905 LB M= 0.75*0.7*Mcol = 683 IN -LB KxLx/rx = 1.2 * 55 IN/0.65 IN = 101.5 <=== (KI/r)max KyLy/ry = 1.2*28 IN/0.7 IN = 48.0 ro= (rx^2 + ry^2 + xo^2)^0.5 = 0.955 IN 8= 1-(xo/ro)^2 1.000 Fe IS TAKEN AS THE SMALLER OF Fel AND Fe2: Fe1= rt^2E/(KL/r)max^2 = 28.2 KSI aex= rt^2E/(KxLx/rx)^2 = 28.2 KSI at= 1/Aro^2[GJ+(r(^2ECw)/(KtLt)^2) = 103.94 KSI Fe2= 1/(2R)*{(aex+at)-[(aex+at)^2-(4*R*aex*at)]^0.5} = 28.2 KSI Fe= 28.2 KSI Fy/2= 18.0 KSI SINCE, Fe > Fy/2 THEN, Fn= Fy(1-Fy/4Fe) = 24.5 KSI Pn= Aeff*Fn = 8,584 LB Oc= 1.92 Pa= Pn/Qc = 4,471 LB P/Pa= 0.20 > 0.15 THUS, CHECK: P/Pa + (Cmx*Mx)/(Max*µx) <_ 1.0 P/Pao + Mx/Max <_ 1.0 Pno= Ae*Fy = 12,600 LB Pao= Pno/Qc = 6,563 LB Me= Cb*ro*Aeff*(sey*st)^0.5 = 38 IN-K My= Sy*Fy = 5,040 IN -LB Mc= My[1-My/(4Me)] = 4,874 IN -LB Max=Maxo= Mc/Of = 2,919 IN -LB µx= {1/[1-(Qc*P/Pcr)]}^-1 = 0.83 THUS, 14 GA. SECTION PROPERTIES A= 3.344 IN B= 1.938 IN (905 LB/4471 LB) + (1*683 IN-LB)/(2919 IN-LB*0.83) = 0.49 <1.0, OK (905 LB/6563 LB) + (683 IN-LB/2919 IN -LB) = 0.37 <1.0, OK t = 0.075 IN Aeff = 0.350 IN^2 Ix = 0.150 INA4 Sx = 0.100 INA3 rx = 0.650 IN ly = 0.170 INA4 Sy = 0.140 IN^3 ry = 0.700 IN J = 0.001 INA4 Cw = 0.062 INA6 xo = 0.00 IN Kx = 1.2 Lx = 55.00 IN Ky = 1.20 Ly = 28.00 IN Kt = 1.0 Lt = 28.00 IN Fy= 36 KSI G= 11,300 E= 29,500 KSI Cmx= 1.0 Cb= 1.0 Of= 1.67 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 35 TC 7/22/2014 Longitudinal Post Analysis Analyzed per AISI. Section properties are based on net effective sections. P=(1+0.11Sps)DL+0.75*(1+0.14Sps)PL = 480 LB M= 0.75*0.7*Mcol = 1,330 IN -LB KxLx/rx = 1.2*55 IN/0.65 IN = 101.5 <=== (KI/r)max KyLy/ry = 1.2*28 IN/0.7 IN = 48.0 ro= (rx^2 + ry^2 + xo^2)^0.5 = 0.955 IN f3= 1-(xo/ro)^2 1.000 Fe IS TAKEN AS THE SMALLER OF Fel AND Fe2: Fe1= rr^2E/(KL/r)max^2 = 28.2 KSI aex= rr^2E/(KxLx/rx)^2 = 28.2 KSI at= 1/Aro^2[G1+(n^2ECw)/(KtLt)^2] = 103.94 KSI Fe2= 1/(2R)*{(aex+ot)-[(csex+at)^2-(4*f3*aex*at)]^0.5} = 28.2 KSI Fe= 28.2 KSI Fy/2= 18.0 KSI SINCE, Fe > Fy/2 THEN, Fn= Fy(1-Fy/4Fe) = 24.5 KSI Pn= Aeff*Fn = 8,584 LB Oc= 1.92 Pa= Pn/Oc = 4,471 LB P/Pa= 0.11 < 0.15 THUS, CHECK: P/Pa + Mx/Max <_ 1.0 Pno= Ae*Fy = 12,600 LB Pao= Pno/Oc = 6,563 LB Me= Cb*ro*Aeff*(sey*st)^0.5 = 38 IN-K My= Sx*Fy = 3,600 IN -LB Mc= My[1-My/(4Me)] = 3,515 IN -LB Max=Maxo= Mc/Of = 2,105 IN -LB µx= {1/[1-(Qc*P/Pcr)]}^-1 = 0.91 THUS, (480 LB/4471 LB) + (1330 IN-LB/2105 IN -LB) = 14 GA. SECTION PROPERTIES A= 3.344 IN B= 1.938 IN 0.74 < 1.0, OK t=0.075IN Aeff = 0.350 IN^2 Ix = 0.150 IN^4 Sx = 0.100 IN^3 rx = 0.650 IN ly = 0.170 INN) Sy = 0.140 IN^3 ry = 0.700 IN J = 0.001 IN^4 Cw = 0.062 IN^6 xo = 0.00 IN Kx = 1.2 Lx = 55.00 IN Ky = 1.20 Ly = 28.00 IN Kt = 1.0 Lt = 28.00 IN Fy= 36 KSI G= 11,300 E= 29,500 KSI Cmx= 1.0 Cb= 1.0 Of= 1.67 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 36 TC 7/22/2014 Double Rivet Beam Connection Since the frame is assumed to resist the seismic loads as a moment resisting frame, the capacity of the rivet beam connection shall be determined and justified. Mconn= 0.75*0.7*Mconn-seismic = 1,330 IN -LB CAPACITY OF STUD IN SHEAR Vallow= 0.4 * Fy * AREA = 1,080 LB Vallow= 0.22* Fu * AREA = 1,080 LB BEARING CAPACITY OF STUDS brg.allow= stud 0 x tmin x Fu = 1,219 LB Mallow= Vallow * d = 1,620 IN -LB > Mconn OK 0= 0.250 IN tmin= 0.075 IN AREA= 0.049 IN^2 Fy= 55,000 PSI Fu-METAL= 65,000 PSI Fu-RIVET= 100,000 PSI 18.11.11 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 37 TC 7/22/2014 Overturning Analysis Fully loaded: Movt = 19,821 IN -LB MDL = 10 LB x 6 Levels x 24.5 IN / 2 = 735 IN -LB MPLaPP = 0.67*175 LB x 6 Levels x 24.5 IN / 2 = 8,618IN-LB Vcol = 0.7*Vtotal/2 = 64 LB d = 24.5IN Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors/Plate = 2 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11SDs) x MDL - 0.75 x (0.6-0.14SDs) x MPLapp] / d = [0.75*0.7*19821 - (0.6-0.11*0.96)*735 - 0.75*(0.6-0.14*0.96)*8618] IN -LB / 24.5 IN = 287 LB <=== UPLIFT Interaction Equation [287 LB/ 740 LB] + [64 LB/ 1080 LB] = 0.45 < 1.2 Therefore OK Top shelf loaded only: Vtop = 56 LB Level hx wx wx hx Fi Movt. 1 2.25 IN 10 LB 23 IN -LB 0 LB 0 IN -LB 2 30.75 IN 0 LB 0 IN -LB 0 LB 0 IN -LB 3 57.75 IN 10 LB 578 IN -LB 1 LB 63 IN -LB 4 75.75 IN 10 LB 758 IN -LB 1 LB 108 IN -LB 5 98.25 IN 10 LB 983 IN -LB 2 LB 181 IN -LB 6 120.75 IN 10 LB 1,208 IN -LB 2 LB 274 IN -LB 7 143.25 IN 185 LB 26,501 IN -LB 50 LB 7,125 IN -LB Movt = 7,751 IN -LB MDL = 735 IN -LB MPLaPP = 175 LB x 24.5 IN / 2 = 2,144 IN -LB Vcol = 0.7*Vtop/2 = 20 LB Total 30,049 IN -LB 56 LB 7,751 IN -LB d = 24.5 IN Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors/Plate = 2 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11SDs) x MDL - 0.75 x (0.6-0.14Sps) x MPLapp] / d = [0.75*0.7*7751 - (0.6-0.11*0.96)*735 - 0.75*(0.6-0.14*0.96)*2144] IN -LB / 24.5 IN = 121 LB <=== UPLIFT INTERACTION EQN. [121 LB/ 370 LB] + [20 LB/ 540 LB] = 0.18 < 1.2 Therefore OK SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 38 TC 7/22/2014 LRFD Load Combination - For Slab and Soil Analysis Load combination per RMI 2.2 Resultant Load combination 1 1.4DL + 1.2PL 1.4DL + 1.2PL 2 1.2DL + 1.6PL + 1.6LL + 0.5(Lr or SL or RL) 1.2DL + 1.6PL 3 1.2DL + 0.85PL + (0.5LL or 0.8WL) + 1.6(Lr or SL or RL) 1.2DL + 0.85PL 4 1.2DL + 0.85PL + 0.5LL + 1.6WL + 0.5(Lr or SI or RL) 1.2DL + 0.85PL 5 (1.2+0.2SDs)DL + (0.85+0.2SDs)PL + 0.5LL + EL + 0.2SL (1.2+0.2SDs)DL + (0.85+0.2SD5)PL + EL 6 (0.9-0.2SDs)DL + (0.9-0.2SDs)PLapp - EL (0.9-0.2SD5)DL+ (0.9-0.2SDs)Plapp - EL DL-total/col = 30 LB LL-total/col = 525 LB E = 809 LB Load combination 1 Pmax = 1.4DL + 1.2PL = 1.4 x 30 LB + 1.2 x 525 LB = 672 LB Load combination 2 Pmax = 1.2DL + 1.6PL = 1.2 x 30 LB+ 1.6 x 525 LB = 876 LB Load combination 3 & 4 Pmax = 1.2DL + 0.85PL = 1.2x30LB+0.85x525 LB = 482 LB Load combination 5 Pmax = (1.2+0.2SD5)DL+ (0.85+0.2SDs)PL + EL = (1.2+0.2*0.96) x 30 LB + (0.85+0.2*0.96) x 525 LB + 809 LB = 1,398 LB Load combination 6 Pmax = (0.9-0.2SD5)DL + (0.9-0.2SD5)PLapp - EL = (0.9-0.2*0.96) x 30 LB + (0.9-0.2*0.96) x 352 LB - 809 LB = -539 LB r1.1711MICIIIIII INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 39 TC 7/22/2014 Slab & Soil Check The slab will be checked for puncture and bearing stress. If no puncture occurs, the slab is assumed to distribute the load over a larger area of the slab. Pmax = 1,398 LB a) Puncture: Fpunct = 2.66 x (F'c^0.5) = 2.66 x (2500 PSI)^0.5 = 133 PSI Apunct = [(Weff.+t/2)+(Deff.+t/2)] x 2 x t = [(5 IN + 5 IN/2) + (2 1N + 5 IN/2)] x 2 x 5IN = 120 IN^2 fv/Fv = P/[(Apunct)(Fpunct)] = 1398 LB/[120 IN^2 x 133 PSI x 0.55] = 0.16 < 1.0 OK b) Bearing: 0Bn = 0.85 x 0 x fc x Al = 11,688 LB Pu / OBn = 1398 LB / 11688 LB = 0.12 < 1.0 OK c) Slab Tension: Adeck = P/[1.0 x fsoil] = 1398 LB/[1.0 x 1500 PSF/(1441NA2/FTA2)] = 134 IN^2 Base Plate: Weff. = 5.00 IN Deff. = 2.00 IN L = Adeck"0.5 Al = 10.00 IN"2 = (134.19 IN^2)^0.5 = 11.6 IN B = [(Weff.)(Deff.)]^0.5 + t = [5IN x 2 IN]^0.5 + 5 Concrete: =8.2IN t=5.00IN b = (L-B)/2 Pc = 2,500 PSI = (11.58 IN - 8.16 IN)/2 = 1.7 IN Mconc = (w)(b^2)/2 = [(1.0)(fsoil)(b"2)]/[144 (IN^2/FT^2) x 2] = [1.0 x 1500 PSI x (1.71 IN)^21/[144 (INA2/FTA2) x 2] = 15 IN -LB Sconc = 1 IN x (t^2)/6 = 1 IN x (5 IN)^2/6 = 4.17 INA3 Fconc = 5 x 0 x fc^0.5 = 5 x 0.55 x (2500 PSI)^0.5 = 137.5 PSI fb/Fb = Mconc/[(Sconc)(Fconc)] = 15.25 IN-LB/[(4.17 INA3)(137.5 PSI)] = 0.03 < 1.0 OK Soil fsoil = 1,500 PSF 0= 0.55 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 40 TC 7/22/2014 Gondola Analysis Project Scope: Provide seismic analysis of the light duty storage fixtures in conformance with the specifications set forth in the 2012 IBC. Parameters: The light duty storage fixtures are pimarily gondolas located on the sales floor. The stability of the shelving depends on the braced frame (peg boards and horizontal braces) along the longitudinal direction. Along the transverse direction the shelving relies on a cantilever frame system for stability. If a system is attached or anchored to the wall, the shelving will transfer all its lateral load to the most rigid component - the wall. The system is prefabricated and is to be field installed only, with no field welding. Storage fixtures will be analyzed utilizing the following formula: Fp=[0.4*aP*Sos*Ip/RP)*Wp*[1+2(z/h)) EXCEPT WHERE: Specifications: Fp shall not be taken as less than 0.3*Sos*Ip*Wp and Fp is not required to be taken as greater than 1.6*Sos*Ip*Wp Ss = 1.44 Fa = 1.00 Main Steel - Columns and Base, Fy =, 50,000 psi Base Connection, Fy = 80,000 psi All others, Fy = 36,000 psi Anchor - 3/8" 0 x 2-1/2" min. embed. Powers Wedge -Bolt+ (ICC ESR-2526) Slab on grade - 5" concrete x 2500 psi Soil - 1500 psf The system will be analyzed with respect to the most critical configuration and forces resulting from both static and seismic forces. SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 41 TC 7/22/2014 Configurations: 1) UPRIGHT 2) BASE 3) ANCHOR 4) BASE DECK 6) SHELF 7) RAIL 5/16" PEG BOARD (CENTER ON UNIT) END TRIM 20 GA. BASE SIDE TRIM 22 GA. BASE FRONT TRIM 22 GA. SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 42 TC 7/22/2014 Summary and Elevations - Single Sided Gondola 48' 144 FRONT VIEW 2 1 /2' 181/4" SIDE VIEW LL/Shelf = 60 Ib LL/Top Shelf only = 200 Ib LL/Panel Loading = 10 psf 48" FRONT VIEW SIDE VIEW Posts HD free. Std Wall I Shelf Panels Stress (Free) = 0.83 Stress (Wall) = 0.50 OK r Stress = 0.43 OK Stress (Free) = 0.44 Stress (Wall) = 0.32 OK Overturning I Base Stress (Free) = 0.73 OK Stress (Free) = 0.72 OK 111 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 43 TC 7/22/2014 Loads & Seismic Distribution Single Sided (Multiple Shelves) Analysis based on Section 1613 of the 2012 CBC and Section 13.3 of the ASCE 7-10 SITE CLASS = D Sim = 0.960 Ip = 1.00 Rp = 2.5 ap = 1 EXCEPT WHERE: AND WHERE Ss = 1.44 & Fa = 1 Fp = [0.4*ap*(2/3*Fa*Ss)*Ip/Rp]*Wp = 0.154 Wp Fp shall not be taken as less than 0.3*(2/3*Fa*Ss)*Ip*Wp = 0.288 Wp not required to be taken as greater than 1.6*(2/3*Fa*Ss)*Ip*Wp = 1.536 Wp Fp (GOVERNS) = 0.288 Wp wPL/base = 300 Ib wPL/shelf = 60 Ib wDL/shelf = 10 Ib # of Levels = 11 Wp = E(0.67*wPL + wDL) = 753 Ib Fp = 159 Ib Level hx wx Fi-trans Fi-long Movt-critical Ground/Base 2 3 4 5 6 7 8 9 10 11 12 6.000 in 18.25 in 30.75 in 43.25 in 55.75 in 68.25 in 80.75 in 93.25 in 105.8 in 118.3 in 130.8 in 144.0 in 0 lb 50 lb 50 Ib 50 Ib 50 Ib 50 Ib 50 lb 50 Ib 50 Ib 50 lb 50 lb 50 lb 0 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 0 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 14 Ib 0 in-Ib 264 in-Ib 445 in-Ib 625 in-Ib 806 in-Ib 987 in-Ib 1,167 in-Ib 1,348 in-Ib 1,529 in-Ib 1,710 in-Ib 1,890 in-Ib 2,082 in-Ib 552 Ib 159 Ib 159 Ib 12,853 in-Ib SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 44 TC 7/22/2014 Loads & Seismic Distribution Single Sided (Top & Panel Loading) Analysis based on Section 1613 of the 2012 CBC and Section 13.3 of the ASCE 7-10 SITE CLASS = D Sps = 0.960 I p = 1.00 Rp = 2.5 ap = 1 EXCEPT WHERE: AND WHERE Sms = Fa*Ss AND Ss = 1.44 & Fa = 1 Fp = [0.4*ap*(2/3*Fa*Ss)*Ip/Rp]*Wp = 0.154 Wp Fp shall not be taken as less than 0.3*(2/3*Fa*Ss)*Ip*Wp = 0.288 Wp not required to be taken as greater than 1.6*(2/3*Fa*Ss)*Ip*Wp = 1.536 Wp Fp (GOVERNS) = 0.288 Wp Panel Area = 48 ftA2 wPL/panel = 5.0 psf wDL/panel = 2 psf wPL/base= 300 Ib wPL/shelf = 200 Ib wDL/shelf = 10 Ib # of Levels = 1 (free standing) <== Top only Wp = E(0.67*wPL + wDL) = 602 Ib Fp = 115 Ib Level hx wx Fi-trans Fi-long Movt-critical Ground/Base 2 3 4 5 6 7 8 9 10 11 12 6.000 in 18.25 in 30.75 in 43.25 in 55.75 in 68.25 in 80.75 in 93.25 in 105.8 in 118.3 in 130.8 in 144.0 in 0 Ib 26 Ib 26 Ib 26 Ib 26 Ib 26 Ib 26 Ib 26 Ib 26 Ib 26 Ib 26 Ib 144 Ib 0 Ib 7 Ib 7 Ib 7 lb 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 41 Ib 0 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 7 Ib 41 Ib 0 in-Ib 135 in-Ib 227 in-Ib 320 in-Ib 412 in-Ib 505 in-Ib 597 in-Ib 690 in-Ib 782 in-Ib 875 in-Ib 967 in-Ib 5,972 in-Ib 401 lb 115 I b 115 Ib 11,482 in-Ib SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 45 TC 7/22/2014 Loads & Seismic Distribution Single Sided (Top & Panel Loading) Analysis based on Section 1613 of the 2012 CBC and Section 13.3 of the ASCE 7-10 SITE CLASS = D Sps = 0.960 Ip = 1.00 Rp = 2.5 ap = 1 EXCEPT WHERE: AND WHERE Sms = Fa*Ss AND Ss = 1.44 & Fa = 1 Fp = [0.4*ap*(2/3*Fa*Ss)*Ip/Rp]*Wp = 0.154 Wp Fp shall not be taken as less than 0.3*(2/3*Fa*Ss)*Ip*Wp = 0.288 Wp not required to be taken as greater than 1.6*(2/3*Fa*Ss)*Ip*Wp = 1.536 Wp Fp (GOVERNS) = 0.288 Wp Panel Area = 48 ft^2 wPL/panel = 10.0 psf (wall attached) wDL/panel = 2 psf wPL/base= 300 Ib wPL/shelf = 200 Ib wDL/shelf = 10 Ib # of Levels = 1 <== Top only Wp = E(0.67*wPL + wDL) = 763 Ib Fp = 162 Ib Level hx wx Fi-trans Fi-long Movt-critical Ground/Base 2 3 4 5 6 7 8 9 10 11 12 6.000 in 18.25 in 30.75 in 43.25 in 55.75 in 68.25 in 80.75 in 93.25 in 105.8 in 118.3 in 130.8 in 144.0 in 0 Ib 42 lb 42 lb 42 lb 42 lb 42 lb 42 lb 42 lb 42 lb 42 lb 42 lb 144 Ib 0 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 41 Ib 0 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 12 Ib 411 b 0 in-Ib 219 in-Ib 370 in-Ib ' 520 in -lb 670 in-Ib 821 in-Ib 971 in-Ib 1,122 in-Ib 1,272 in-Ib 1,422 in-Ib 1,573 in-Ib 5,972 in-Ib 5621b 1621b 162 Ib 14,932 in-Ib SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 46 TC 7/22/2014 Transverse Analysis Multiple Shelves Type L (Free Standing) Ptotal = (1+0.11SDs) * D L + 0.75 * (1+0.14SDs) * P L = 683 lb Mstatic = (wPL+wDL)/shelf x Arm length x # of Levels / 2 = 10,165 in -lb Mseis. = 12,853 in -lb <=== Please see Loads & Distribution Page Mtotal = Mstatic + 0.7*0.75*Mseis. = 16,913 in -lb Top & Panel Loading Type L (Free Standing)) Ptotal = (1+0.11Sos)*DL + 0.75*(1+0.14SDs)*PL = 181 lb depth (16" deep + 3" post) = 19.00 in Width = 48.00 in Height = 144.0 in depth (16" deep + 3" post) = 19.00 in Width = 48.00 in Height = 144.0 in Mstatic = (wPL+wDL)/shelf x Arm length x # of Levels / 2 + (wPL+wDL)/panel x 3" = 5,853 in -lb Mseis. = 11,482 in -lb <=== Please see Loads & Distribution Page Mtotal = Mstatic + 0.7*0.75*Mseis. = 11,881 in -lb Top & Panel Loading Type L (Wall Attached) Ptotal =(1+0.11SDs)*DL+0.75*(1+0.14SDs)*PL = 181 lb depth (16" deep + 3" post) = 19.00 in Width = 48.00 in Height = 144.0 in Mstatic = (wPL+wDL)/shelf x Arm length x # of Levels / 2 + (wPL+wDL)/panel x 3" = 6,573 in -lb Mseis. = 14,932 in -lb <=== Please see Loads & Distribution Page Mtotal = Mstatic + 0.7*0.75*Mseis. = 14,412 in -lb Per Section 1607.13 of the 2009 IBC, "Interior walls and partitions that exceed 6 feet in height, including their finish materials, shall have adequate strength to resist the loads to which they are subjected to but not less than a horizontal load of 5 psf.". Fp-wall = Fp-total / (Width x Height) = 115 lb / (48 ft^2) = 2.4 psf < 5 psf, OK SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 47 TC 7/22/2014 Transverse Column Analysis - Floor anchored Analyzed per AISI. Section properties are based on net effective sections. P= 683 Ib M. 16,913 in-Ib KxLx/rx = 2.1 x 138 in/1.2042 in = 240.7 <=== (KI/r)max KyLy/ry = 1 x 48 in/0.5951 in = 80.7 ro= (rx^2 + ryA2 + xo^2)"0.5 = 1.343 in I = 1-(xo/ro)^2 = 1.000 Fe is taken as the smaller of Fel and Fe2: Fe1= tt^2E/(KL/r)max^2 = 5.03 ksi aex= rt^2E/(KxLx/rx)^2 = 5.03 ksi at= 1/Aro^2[GJ+(rt^2ECw)/(KtLt)^2] = 31.32 ksi Fe2= 1/(2I) x {(aex+ot)-[(6ex+at)^2-(4 x f3 x 6ex x at)1^0.51 = 5.03 ksi Fe= 5.03 ksi Fy/2= 27.50 ksi Since, Fe < Fy/2 Then, Fn= Fe = 5.03 ksi Pn= Aeff x Fn = 6,395 Ib Qc= 1.92 Pa= Pn/Oc = 3,330 Ib P/Pa= 0.21 > 0.15 Thus, check: P/Pa + (Cmx*Mx)/(Max*µx) <_ 1.0 P/Pao + Mx/Max <_ 1.0 Pno= Ae x Fy = 69,960 Ib Pao= Pno/Qc = 36,438 Ib Me= Cb x ro x Aeff x (aey x ot)^0.5 = 64 in -kip My= Sx x Fy = 64,922 in-Ib Mc= My[1-My/(4Me)] = 48,449 in-Ib Max=Maxo= Mc/Of = 29,011 in-Ib µx= {1/[1-(Qc*P/Pcr)]}^-1 = 0.79 Thus, SECTION PROPERTIES A= 1.313 in B= 3.125 in C= 0.000 in t = 0.063 in t = 0.152 in Aeff = 1.272 in^2 Ix = 1.844 in^4 Sx = 1.180 in^3 rx = 1.204 in ly = 0.450 in"4 Sy = 0.463 in"3 ry = 0.595 in J = 0.006 in^4 Cw = 0.014 in"6 xo = 0.000 in Kx = 2.1 Lx = 138.00 in Ky = 1.0 Ly = 48.00 in Kt = 1.0 Lt = 48.00 in Fy= 55 ksi G= 11,300 E= 29,500 ksi Cmx= 0.85 Cb= 1.0 Of= 1.67 (683 lb/3330 Ib) + (0.85 x 16913 in-lb)/(29011 in-Ib x 0.79) = 0.83 <1.0, OK (683 lb/36438 Ib) + (16913 in-lb/29011 in-Ib) = 0.60 <1.0, OK SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 48 TC 7/22/2014 Transverse Column Analysis - Wall attached Analyzed per AISI. Section properties are based on net effective sections. P= 181 Ib M= 14,412 in -lb KxLx/rx = 1 x 138 in/1.2042 in = 114.6 <=== (KI/r)max KyLy/ry = 1 x 48 in/0.5951 in = 80.7 ro= (rx^2 + ry^2 + xo^2)^0.5 = 1.343 in f3= 1-(xo/ro)^2 = 1.000 Fe is taken as the smaller of Fel and Fe2: Fe1= Tt^2E/(KL/r)max^2 = 22.17 ksi hex= rt^2E/(KxLx/rx)^2 = 22.17 ksi at= 1/Aro^2[GJ+(tt^2ECw)/(KtLt)^2] = 31.32 ksi Fe2= 1/(2B) x {(aex+at)-[(aex+at)^2-(4 x (3 x aex x at)]^0.5} = 22.17 ksi Fe= 22.17 ksi Fy/2= 27.50 ksi Since, Fe < Fy/2 Then, Fn= Fe = 22.17 ksi Pn= Aeff x Fn = 28,200 Ib Qc= 1.92 Pa= Pn/Qc = 14,687 Ib P/Pa= 0.01 < 0.15 Thus, check: P/Pa + Mx/Max <_ 1.0 Pno= Ae x Fy = 69,960 Ib Pao= Pno/Qc = 36,438 Ib Me= Cb x ro x Aeff x (aey x at)^0.5 = 64 in -kip My= Sx x Fy = 64,922 in -lb Mc= My[1-My/(4Me)] = 48,449 in -lb Max=Maxo= Mc/Of = 29,011 in -lb µx= {1/[1-(C2c*P/Pcr)]}^-1 = 0.99 IS SECTION PROPERTIES A= 1.313 in B= 3.125 in C= 0.000 in t=0.063in t = 0.152 in Aeff = 1.272 in^2 Ix = 1.844104 Sx = 1.180 in^3 rx = 1.204 in ly = 0.450 in^4 Sy = 0.463 in^3 Ty = 0.595 in J = 0.006 inA4 Cw = 0.014 in^6 xo = 0.000 in Kx = 1.0 Lx = 138.00 in Ky = 1.0 Ly = 48.00 in Kt = 1.0 Lt = 48.00 in Fy= 55 ksi G= 11,300 E= 29,500 ksi Cmx= 0.85 Cb= 1.0 Of= 1.67 Thus, (181 lb/14687 lb) + (14412 in-Ib/29011 in -lb) = 0.50 <1.0, OK r SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 49 TC 7/22/2014 Arm Check Arm Analysis: Mmax = (wPL+wDL)/shelf x Arm Length / 2 = 210 Ib x 16 in/2 = 1,680 in -lb fb = Mmax/Sx = 1680 in -lb / 0.705 inA3 = 2,383 psi Fb = 0.6 x Fy = 21,600 psi fb / Fb = 0.11 < 1.0 Therefore Ok Arm Bracket Analysis: Mmax = 1,680 in -lb Tcap = 0.6 x Fy x Area = 0.6 x 36000 psi x 0.09 inA2 = 1,9441b Mcap= Txd = 19441bx2in = 3,888 in -lb Mmax/Mcap = 0.43 < 1.0 Therefore Ok �, GA. Arm Length = 16.00 in Sx = 0.705 in^3 A = 0.090 in^2 d = 2.00 in Fy = 36,000 psi • SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 50 TC 7/22/2014 Base Analysis Base Check: Mmax = 16,913 in-Ib fb = Mmax / Sx = 16913 in-Ib / 0.78 in^3 = 21,683 psi Fb = 0.6 x Fy = 30,000 psi fb / Fb = 0.72 < 1.0 Therefore Ok Base Connection Check: Top to Bottom Mmax x 12o = 16913 in-Ib x 2 = 33,825 in-Ib Tcap-top = 0.6 x Fy x Thickness x Min. Width = 0.6 x 80000 x 0.121 in x 0.376 in = 2,184 Ib 5.93" 1.35" Mcap = [P1 x L1 + P2 x L2 + P3 x L3] x 2 sides = P1 x [L1 + (L2^2 + L3^2)/L1] x 2 sides = 2184 Ib x [3.548 + (2.605^2 + 1.1091'2)/3.548] in x 2 sides = 25,364 in-Ib Bottom to Top Mmax xS2o= 16913 in-Ib x 2 = 33,825 in-Ib Tcap-bottom = 0.6 x Fy x Thickness x Min. Width = 0.6 x 80000 x 0.121 in x 1.718 in = 9,978 Ib Mcap = [P1 x L1 + P2 x L2 + P3 x L3] x 2 sides = P1 x [L1 + (L2^2 + L3^2)/L1] x 2 sides .594" .282" .727" .273" 1.968" r El I = 9978 Ib x [2.709 + (1.241'2 + 0.2971'2)/2.709] in x 2 sides = 66,038 in-Ib Mcap-eff. x 2 = 50,728 in-Ib <=== NOTE: THERE ARE (2) BASES Mmax/Mcap = 0.67 < 1.0 Therefore Ok Sx = 0.780 in^3 Fy = 50,000 psi S2o = 2.0 Material Thickness = 0.121 in Top Width = 0.376 in L-top = 3.548 in L-middle = 2.605 in Lbottom = 1.109 in Fy = 80,000 psi .797" .376" .529" 1.718" S2o = 2.0 Material Thickness = 0.121 in Bottom Width = 1.718 in L-top = 2.709 in L-middle = 1.240 in Lbottom = 0.297 in Fy = 80,000 psi r SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 51 TC 7/22/2014 Overturning Analysis Freestanding Units: Fully Loaded Conditions: 4 ,- l 4 4 4 1 4 4- 4 4 4 4 4 4 Mstatic - Mseismic [Mstatic - Mseismicydepth Puplift = [(0.7*Mseismic - 0.6*Mstatic) / danchor] x # of occurrence = [(0.7*11482 - 0.6*5853) in-Ib / 20 in] x 1 = 229 Ib Interaction Eqn: Allowable Tension = 370 Ib Allowable Shear = 540 Ib # of Anchors/base = 1 danchor (16" base + 3" post) = 19.8 in # of Occurrence = 1 [229 Ib/ 370 Ib] + [58 Ib/ 540 Ib] = 0.73 < 1.2 Therefore Ok Wall Attached Units: The wall units will be attached to 2" x 6" wood board furring strips running at about the 6" elevation and 138" elevation. The strips will be attached to the wall and the fixtures will be attached to the strips. Fp,max/2 = 81 Ib For concrete wall: Use 3/8"0 x 2-1/2" min. embed. LDT screw anchor @ 24" o/c For steel wall studs: Use #8 Teks Screws For wood wall studs: Use 1/4" 0 Lag Screws SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 52 TC 7/22/2014 Light Duty Storage Racks Project Scope: The purpose of this analysis is to show that the following light duty storage fixtures complies with the specifications set forth in Section 1613 of the 2012 IBC and Section 15.5.3 of ASCE 7-10. The storage racks are prefabricated and are to be field installed only without any field welding. Project Parameters: The system will be analyzed for seismic loading utilizing the following equation: Seismic Factors: Project Specifications: Configurations: V = Cs x W Cs=Spsxl/R Sps = 2/3 x Fa x Ss 1 = 1.5 R= 4 Fa = 1.00 Ss = 1.44 Steel - Shaped steel & Rods, ASTM A570 Grade 55, Fy = 55,000 psi All others, ASTM A36, Grade 36, Fy = 36,000 psi Bolts - ASTM A307 unless otherwise noted Anchors - 3/8" 0 x 2-1/8" min. embed. Powers Wedge Bolts(ICC ESR-2526) Slab - 5" x 2,500 PSI Soil - 1,500 PSF Type X2 Type X3 144"H x 72"W x 38"D 144"H x 96"W x 38"D <=== critical config. to be analyzed SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 53 TC 7/22/2014 Loads & Distribution: Seismic Shear: Fa = 1.00 Ss = 1.44 Sps = 2/3*Fa*Ss = 0.96 I = 1.5 R = 4 Cs=Sps*I/R = 0.360 # of Shelf level = 5 Shelf PL = 150 LB/Level Shelf DL = 20 LB/Level Total wPL = 750 LB Total wDL = 100 LB <__= ASSUMED SITE CLASS D <=== IN AREA OPEN TO THE PUBLIC Ws = E(0.67*wPL+wDL) = 603 LB Vtotal = Cs*Ws = 0.36 x 603 LB = 217 LB Depth = 38.0 IN Vtop = Cs*Ws,top = 0.36 x 250 LB = 90 LB Level W hx wx hx Fi Movt 1 2 3 4 5 170 LB 170 LB 170 LB 170 LB 170 LB 6.0 I N 29.0 IN 52.0 IN 98.0 IN 144.0 IN 1,020 IN -LB 4,930 IN -LB 8,840 IN -LB 16,660 IN -LB 24,480 IN -LB 4.0 LB 19.1 LB 34.3 LB 64.7 LB 95.0 LB 24 IN -LB 555 IN -LB 1,784 IN -LB 6,337 IN -LB 13,682 IN -LB 850 LB 55,930 IN -LB 217 LB 22,382 IN -LB SEIZMIC 1 INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 54 TC 7/22/2014 Transverse Front Column Analysis: Analyzed per AISI. Section properties are based on net effective sections. Pcol=(1+0.11SD5)DL+0.75*(1+0.14SD5)PL+0.75*0.7*EL = 684 LB KxLx/rx = 1*144 IN/0.718 IN = 200.6 KyLy/ry = 1*144 IN/0.647 IN = 222.6 (KL/r)max = 222.6 ro= (rx"2 + ry^2 + xo^2)^0.5 = 1.938 IN 8= 1-(xo/ro)^2 = 0.249 Fe IS TAKEN AS THE SMALLER OF Fel AND Fe2: Fe1= n^2E/(KL/r)max^2 = 5.9 KSI SECTION PROPERTIES hex= n^2E/(KxLx/rx)^2 A = 1.750 IN = 7.2 KSI B = 1.750 IN at= 1/Aro^2[GJ+(n^2ECw)/(KtLt)^2] C = 0.500 IN = 7.03 KSI t = 0.075 IN Fe2= 1/(2R)*{(aex+at)-[(aex+at)^2-(4*@*aex*o-t)]^0.5} Aeff = 0.435 IN^2 = 3.8 KSI Ix = 0.224 IN^4 Sx = 0.256 IN^3 Fe= 3.8 KSI rx = 0.718 IN Fy/2= 27.5 KSI ly = 0.182 IN"4 SINCE, Fe < Fy/2 Sy = 0.185 IN"3 THEN, Fn= Fe ry = 0.647 IN = 3.8 KSI J = 0.001 INA4 Cw = 0.174 INA6 Pn= Aeff*Fn xo = -1.680 IN = 1,662 LB Kx = 1.0 Lx = 144.00 IN Oc= 1.92 Ky = 1.00 Ly = 144.00 IN Kt = 1.00 Pa= Pn/Qc Lt = 144.00 IN = 865 LB Fy = 55 KSI Pcol/Pa= 0.79 < 1.0, OK G = 11,300 E = 29,500 KSI 1 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 55 TC 7/22/2014 Transverse Rear Column Analysis: Analyzed per AISI. Section properties are based on net effective sections. P=(1+0.11Sps)DL+0.75*(1+0.14Sps)PL 749 LB M= 0.75*0.7*Movt = 11,750 IN -LB KxLx/rx = 1 x 144 IN/0.989 IN = 145.6 <=== (KI/r)max KyLy/ry = 1 x 46 IN/0.587 IN = 78.4 2 5/8" ro= (rx^2 + ry^2 + xo^2)^0.5 = 1.150 IN 13= 1-(xo/ro)^2 = 1.000 Fe is taken as the smaller of Fel and Fe2: Fe1= n^2E/(KL/r)max^2 = 13.73 ksi aex= n^2E/(KxLx/rx)^2 = 13.73 ksi at= 1/Aro^2[GJ+(n^2ECw)/(KtLt)^2] = 44.49 ksi Fe2= 1/(26) x {(aex+at)-[(aex+at)^2-(4 x I3 x aex x at)]^0.5} = 13.7 KSI Fe= 13.7 KSI Fy/2= 27.5 KSI Since, Fe < Fy/2 Then, Fn= Fe Aeff = 1.202 INA2 = 13.7 KSI Ix = 1.175 IN^4 Pn= Aeff x Fn Sx = 0.905 IN^3 = 16,504 LB rx = 0.989 IN Oc= 1.92 ly = 0.414 INA4 Sy = 0.427 IN^3 Pa= Pn/Qc ry = 0.587 IN = 8,596 LB J = 0.006 IN^4 P/Pa= 0.09 < 0.15 Cw = 0.012IN^6 Thus, check: P/Pa + Mx/Max < 1.0 xo = 0.000 IN Kx = 1.0 Pno= Ae x Fy Lx = 144.00 IN = 66,094 LB Ky = 1.00 Pao= Pno/Qc Ly = 46.00 IN = 34,424 LB Kt = 1.00 Me= Cb x ro x Aeff x (aey x at)^0.5 Lt = 46.00 IN = 63 IN-K Fy= 55 KSI My= Sx x Fy G= 11,300 = 49,775 IN -LB E= 29,500 KSI Mc= My[1-My/(4Me)] Cmx= 0.85 = 40,017 IN -LB Cb= 1.0 Max=Maxo= Mc/Of Of= 1.67 = 23,962 IN -LB µx= {1/[1-(Qc*P/Pcr)]}^-1 = 0.91 Thus, (749 LB/8596 LB) + (11750 IN-LB/23962 IN -LB) = 0.51 <1.0, OK _____________ SECTION PROPERTIES 1.4 SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE BUY BUY BABY #3098 BED BATH & BEYOND 56 TC 7/22/2014 Overturning Analysis Fully loaded: Movt = 22,382 IN -LB MDL= 100LBx38IN/2 = 1,900 IN -LB MpLapp = 0.67*750 LB x 38 IN / 2 = 9,548 IN -LB Vcol = 0.7*Vtotal/2 = 76 LB d = 38.0 IN Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors/Plate = 1 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11Sps) x MDL - 0.75 x (0.6-0.14SDs) X MpLapp] / d = [0.75*0.7*22382 - (0.6-0.11*0.96)*1900 - 0.75*(0.6-0.14*0.96)*9548] IN -LB / 38 IN = 197 LB <=== UPLIFT Interaction Equation [197 LB/ 370 LB] + [76 LB/ 540 LB] = 0.67 < 1.2 Therefore OK Top shelf loaded only: Vtop = 90 LB Level hx wx wx hx Fi Movt. 1 6.00 IN 20 LB 120 IN -LB 0 LB 2 IN -LB 2 29.00 IN 20 LB 580 IN -LB 2 LB 54 IN -LB 3 52.00 IN 20 LB 1,040 IN -LB 3 LB 173 IN -LB 4 98.00 IN 20 LB 1,960 IN -LB 6 LB 613 IN -LB 5 144.00 IN 170 LB 24,480 IN -LB 78 LB 11,258 IN -LB Movt = 12,101 IN -LB Mpg = 1,900 IN -LB MpLapp = 150 LB x 38 IN / 2 = 2,850 IN -LB Vcol = 0.7*Vtop/2 = 32 LB Total I 28,180 IN -LB 90 LB 12,101 IN -LB d = 38.01N Allowable Tension = 370 LB Allowable Shear = 540 LB # of Anchors/Plate = 1 Puplift = [0.75 x 0.7 x Movt - (0.6-0.11SDs) x MDL - 0.75 x (0.6-0.14SDs) X MpLapp] / d = [0.75*0.7*12101 - (0.6-0.11*0.96)*1900 - 0.75*(0.6-0.14*0.96)*2850] IN -LB / 38 IN = 116 LB <=== UPLIFT INTERACTION EQN. [116 LB/ 370 LB] + [32 LB/ 540 LB] = 0.37 < 1.2 Therefore OK City of Tukwila Department of Community Development December 5, 2014 Keri Putnam 161 Atlantic Street Panoma, CA 91722 RE: Application No. D14-0248 Buy Buy Baby 17686 Southcenter Pkwy Dear Keri Putnam: Jim Haggerton, Mayor Jack Pace, Director Permit application D14-0248 for the work proposed at Buy Buy Baby (17686 Southcenter Pkwy) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of Approved and is due to expire 01/31/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall t Technician File No: D14-0248 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development August 25, 2014 KERI PUTNAM 161 ATLANTIC ST POMONA, CA 91722 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D14-0248 BUY BUY BABY - 17686 SOUTHCENTER PKWY Dear KERI PUTNAM, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • It is assumed that the existing fire sprinkler density for the space is .20/1500 as this is the minimum required density for mercantile occupancies. NFPA 13, Table 13.2.1 shows the maximum storage height allowed for class 4 commodities under the existing density would be 10 ft. The racking shown is 12 ft. high. Storage over 10 ft. high would require a minimum sprinlder density of .30/2500. Storage height over 12 ft. would no longer be considered miscellaneous storage and require and even substantially higher sprinkler density. Please address this issue and state exactly what the maximum storage height will be. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, Jennifer Marshall \Permit Technician FileNo. D14-0248 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PM1T COOR COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0248 DATE: 09/16/2014 PROJECT NAME: BUY BUY BABY SITE ADDRESS: 17686 SOUTHCENTER PKWY Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division ❑ Public Works n G10`01[419 ire Prevention 4' Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/23/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/21/14 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: c4)cAaiy trkk REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0248 DATE: 07/31/14 PROJECT NAME: BUY BUY BABY SITE ADDRESS: 17686 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Bing Division Public Works n Fire Prevention Structural Planning Division Permit Coordinator 1 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 08/05/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: &-004.4,3 Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 09/02/14 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan CheckfPermit Number: D14-0248 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Buy Buy Baby Project Address: 17686 Southcenter � �P�kwy Contact Person: 9.A N / C Y \ A Phone Number: Summary of Revision: buy buy Baby stores Class I - IV commodities and limited Group A plastics on back to back solid shelves up a maximum storage height of 16'-6". The store is protected with a fire sprinkler system with a design density of 0.70 / 2, 500 gpm/sq ft throughout the sales and QIx'vr litinnu SEP 16 2014 PERMIT CENTER pre -sales areas. The fire sprinkler and high piled storage drawings have been included in the re -submittal. SheetNumber(s): HPS1.0, FPD1.0, FPD1.1, FP1.0, FP1.1, FP1.2, FP1.3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on C:\Users\jennifer-m\Desktop\Revision Submittal Form.doc Revised: May 2011 COAST TO COAST FIXTURING hrr, Page 1 of 2 Washington State Department of Labor & industries COAST TO COAST FIXTURING INC Owner or tradesperson WRIGHT, DARREN BRIAN Principals WRIGHT, DARREN BRIAN, PRESIDENT PIERCE, CHARLES HANSEL, SECRETARY (End: 01/21/2015) WA UBI No. 602 543 828 1229 CORONET DRIVE DALTON, GA30720 706-259-4014 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties INST EQUIP/STAT FURN/LAB T/LO License no. COASTCF955OT Effective — expiration 11/10/2005— 01/21/2017 Bond HARTFORD FIRE INS Bond account no. 22BSBDR5959 $6,000.00 Received by L&I Effective date 11/10/2005 10/12/2005 Cancelation date 03/10/2015 Insurance Liberty Mutual Ins Co $1,000,000.00 Policy no. BK856379294 Received by L&I Effective date 01/21/2015 01 /01 /2015 Expiration date 01/01/2016 Insurance history https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602543828&LIC=COASTCF955OT&SAW= 01/23/2015