HomeMy WebLinkAboutPermit D14-0250 - WILBUR ELLIS - TENANT IMPROVEMENTWILBUR ELLIS
16300 CHRISTENSEN RD
STE 207
D14-0250
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
DEVELOPMENT PERMIT
2523049078
16300 CHRISTENSEN RD 207
Project Name: WILBUR ELLIS
Permit Number: D14-0250
Issue Date: 9/3/2014
Permit Expires On: 3/2/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
BRCP RIVERVIEW PLAZA LLC
248 HOMER AVE , PALO ALTO, WA,
94301
TARA STROYAN
1326 FIFTH AVE, STE 400 , SEATTLE,
WA, 98101
PATTISON GENERAL CONTRACTOR
Phone: (206) 587-7120
Phone: (425) 978-8222
15235 NE 90TH ST BLDG U,
REDMOND, WA, 98052
PATTIGC917C7 Expiration Date:
SELF FUNDED - UNICO PROPERTIES
16040 CHRISTENSEN RD , TUKWILA,
WA, 98188
DESCRIPTION OF WORK:
INTERIOR TENANT IMPROVEMENT OF NEW WALL AND DOOR
Project Valuation: $20,000.00
Type of Fire Protection: Sprinklers: YES
Fire Alarm: YES
Type of Construction: IIB
Fees Collected: $824.42
Occupancy per IBC: B
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering: Volumes: Cut: 0 Fill: 0
Landscape Irrigation:
Sanitary Side Sewer: Number: 0
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: No
Permit Center Authorized Signature:
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date: ` kL
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall
be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay
bracing.
5: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
6: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
25: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all
purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC
906.3) (NFPA 10, 5.4)
11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40
pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-
held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that
its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the
bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC
906.9)
12: Extinguishers shall be located in conspicuous locations where they will be readily accessible and
immediately available for use. These locations shall be along normal paths of travel, unless the fire code
official determines that the hazard posed indicates the need for placement away from normal paths of
travel. (IFC 906.5)
13: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached
that indicates the month and year that the inspection was performed and shall identify the company or
person performing the service. Every six years stored pressure extinguishers shall be emptied and
subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire
extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher
service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3)
15: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge
or effort. (IFC 1008.1.8.3 subsection 2.2)
16: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the
door handle is engaged from inside the tenant space. (IFC Chapter 10)
18: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by
Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of
the wrist to operate. (IFC 1008.1.9.1)
17: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
19: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall
comply with the requirements of this section. Aisles or aisle access ways shall be provided from all
occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or
equipment. The required width of aisles shall be unobstructed. (IFC 1017.1)
23: Fire protection systems shall be maintained in accordance with the original installation standards for that
system. Required systems shall be extended, altered or augmented as necessary to maintain and continue
protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems
shall be done in accordance with applicable standards. (IFC 901.4)
21: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3)
20: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory
Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire
Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. (City Ordinance No. 2436).
24: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code.
(NFPA 70)
26: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that
set forth in Table No. 803.9 of the International Building Code.
27: In order to provide you with the fastest police and fire protection under emergency conditions, please post
your suite, room or apartment number in a conspicuous place near the main entry door.
22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
29: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE FINAL
0409 FRAMING
0606 GLAZING
0406 SUSPENDED CEILING
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188.
http://www.TukwilaWA.gov
Building Permit No. 0—S-0
Project No.
Date Application Accepted: 8-- Ivi
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: I lo`cy _(
Tenant Name: k Iv1� \1 \).(
PROPERTY OWNER
Name: 1 't y j co prolvAxis
Address: 11(��4 ('\ L. , _Y..jn�fpm yn 1
l(1 `, �JKStaatte `kopi25�
/ ` e ` Zip:TC(1L\;,!
City: To
CONTACT PERSON - person receiving all project
communication
�
Name: '-{ten �,y �^, �,
t l+lJl W c� � �( �
Address: 1r j
V �J
City: p` Zip01` 0
State: V t c
�►`
Phone: .L�1 l[1ix:
. J U1 • )
-
Emailvrs,,- A ►ou„si01 n.1.\;
GENERAL CONTRACTOR INFORMATION
Company Name:
Address:
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
King Co Assessor's Tax No.: .—S2- 4C1,01$
Suite Number: 201 Floor: 1
New Tenant: Yes ❑..No
ARCHITECT OF RECORD
Company Name:
Architect Name:
t v�
Address: 1`
c
City: 9got
State:j A A Zip:
\131
Phone: � p .S.1 1 IPx: aDt?
(`36
Email: arb-SJYJOM
(71.XC
A,cY.
ENGINEER OF RECORD
Company Name:-TY rVIN
1 -
Engineer Name:
Address:
City: State:
Zip:
Phone: Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name. ;�Q
_ '\
�0
-1i_
�
d�'�-�
Address
City:
Sate:
Zip:
H.\Applications,Forms-Applications On Line'2011 Appbcat ionsWennit Application lie, ised - 8-9-
Revised Aouosi 2011
bh
Page I of4
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ 7J-0) 0790 Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
*TiWerYNOL-7\--
Will there be new rack storage? ❑ Yes
wdk awUI cQar.
No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
2b�2
2na Floor
9.$ vi
6�6sV
3`d Floor
Z 412—
Wtir?'
:A
lJ
Floors thru
/
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): - Floor area of principal dwelling: 1"-.4/ Floor area of accessory dwelling: U`-"�
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Q•J!a'
Will there be a change in use?
0 Yes
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers lk Automatic Fire Alarm
Compact: O P
No If"yes", explain:
Handicap:
❑ None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If ''yes', attach list of materials and storage locations on a separate 8-1/2 " x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System - For on -site septic system. provide 2 copies of a current septic design approved by King County Health
Department.
FI \, pplicationstFonus-Applications On I_mc 2011 Applicot ionsll'ennit Application Revised - $ -11 docx
Revised: August 2011
bh
Page 2 of 4
PUBLIC WORKS PERMIT INFORMATION — 206-433-0179
Scope of Work (please provide detailed information):
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila El ... Water District #125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certificate
❑ .. Highline
0...Valley View ❑ .. Renton
❑...Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Septic System:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage) 0 .. Geotechnical Report ❑...Traffic Impact Analysis
❑ ...Bond 0 .. Insurance ❑ .. Easement(s) 0 .. Maintenance Agreement(s) ❑...Hold Harmless — (SAO)
0... Hold Harmless — (ROW)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way 0
❑ ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
❑ ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑ ...Frontage Improvements
0 ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Abandon Septic Tank
❑ .. Curb Cut
❑ .. Pavement Cut
0 .. Looped Fire Line
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ ...Permanent Water Meter Size... 31 WO #
❑ ...Temporary Water Meter Size .. WO #
0 ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size
❑ ...Sewer Main Extension Public ❑ Private ❑
❑ ...Water Main Extension Public 0 Private ❑
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
0 ...Water ❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
City State Zip
Water Meter Refund/Billing:
Name:
Mailing Address:
Day Telephone:
City
State Zip
tl:\Applications,.Forms-Applications On Li ne12011 Applications Perini! Application Revised - 8-O-I Ldocc
Revised: August 2011
bh
Page 3 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 OR AUT ED AGENT:
Signature: 1 Date: 1. 31 . A —
Print Name: \ C� �� "� `' '� Day Telephone: Q. _E 1. l L 24
Mailing Address: P-5242 r l' �.14) / Y))°1--g1,1)\
City ✓ ate Zip
fhkApplications,Forms-Apphcalions On I_ine'201 1 ApplicaiionskPermit ,Application Re%ised - 0-n-11 docs
Revised, August 2011
bit
I'aae 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I ACCOUNT I QUANTITY
PermitTRAK
I PAID
$510.92
D14-0250 Address: 16300 CHRISTENSEN RD 207 Apn: 2523049078
$510.92
DEVELOPMENT
$486.80
PERMIT FEE
R000.322.100.00.00
0.00
$482.30
WASHINGTON STATE SURCHARGE
8640.237.114
0.00
$4.50
TECHNOLOGY FEE
$24.12
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2989
R000.322.900.04.00 0.00
$24.12
$510.92
Date Paid: Wednesday, September 03, 2014
Paid By: NANCY ANDERSON UNICO
Pay Method: CREDIT CARD 002895
Printed: Wednesday, September 03, 2014 10:40 1 of 1
AM
CFRWSYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT I QUANTITY I PAID
PermitTRAK
$313.50
D14-0250 Address: 16300 CHRISTENSEN RD 207 Apn: 2523049078
$313.50
DEVELOPMENT
$313.50
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R2757
R000.345.830.00.00
0.00
$313.50
$313.50
Date Paid: Friday, August 01, 2014
Paid By: BURGESS DESIGN INC
Pay Method: CHECK 013162
Printed: Friday, August 01, 2014 8:56 AM 1 of 1
CPWSYSTEMS
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431-2451
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
(206) 431-3670
Project:
M' 1 G I) r £fl ‘'S
Type of Inspection;
A72--, ,16
r- IVA-
Address:
Date Called:
Special Instructions:
2,,. )7
(J Spf'' /C l'e
Date Wanted:
a.m.
Requester:
No
Phoned ` - j 2-3
_ - ' i 3.
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
(�( Lr G-,) AA oteTio
nspector:
Date: / -7 _
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO. 6
CITY OF TUKWILA BUILDING DIVISION •
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project: I
LA), (b t) % €( S
Type of Inspection:
5 u S. (e: L.,. n 4
Address:
(a 3 . o &at/ Cie .11
./
Date Called:
Special Instructions:
�7-
3 C.J t � 2-0"7
Date Wanted -, —
` Zitl�
a.m.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
f `. 0 i� i
, 01A 0
,r3--..-j-`ac /I (Tr
.a1'+ V,
%
.�
r
f) tr - 5 '-'
_
c -OK Jcr
S, b P_ cat
D
�
A
InspE ctor:
Date -1 J / 4
—1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSP CTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION- ---
6300 Southcenter Blvd., #100, Tukwila. WA 98188 {206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
Type of Inspection:
Address:
1(0 Do C14-105 GI -a '
(2-P
Date Called: j'
(�j
Special Instructions:
Date Wanted:
a.m.
Requester: Jl
Phone No: lt/
21 -
S 19)
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
InspeEtor: A/ "
, N3REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date: 14-
INSPECTION RECORD
Retain a copy with permit
INSPECTION NUMBER
2)C
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: 0./ , (IL �
4cr is
Type of Inspection: 1
�Usi r 5 1 it, tar i
Address:
Suite #: /63o0 (%,, w,_ ,_
2
Contact Person:
/
Special Instructions:
Phone No.:
_Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector::
y`
(7"--
Date: /a/ AL(
Hrs.:
(- d
$100.00 REINSPECTION FEE REQUIRED. You will receive,an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Address:
Company Name:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
i
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
1 q- 0 Z. so
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
\x./ 1(�lti
Type of Inspection:
,-.-- n,
1 f/A
f r c
Address:
Suite #: ICab o
,41,, ILA
Contact Person:
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
FA
Ai0T 444,17�3 r /4,, -/
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspect6r:
Jc-
�
j
Date: ,o 4. j4.7
Hrs.:
/. d
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D14-0250
PROJECT NAME: WILBUR ELLIS
DATE: 08/01/14
SITE ADDRESS: 16300 CHRISTENSEN RD - SUITE 207
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
As At g
Building Division
£1t1M 4105' (`I
Public Works
/MG ° It .I Lt
Fire Prevention
Structural
n
I4,P O ILf
Planning Division
Permit Coordinator IN
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 08/05/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 09/02/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials:
12/18/2013
PATTISON GENERAL CONTRAC —(A
Page 1 of 2
Washington State Department of
Labor & industries
PATTISON GENERAL CONTRACTOR
Owner or tradesperson
PATTISON, MICHAEL WINFIELD
Principals
PATTISON, MICHAEL
WINFIELD, PRESIDENT
PATTISON, JAN LA REE LOUISE, VICE
PRESIDENT
Doing business as
PATTISON GENERAL CONTRACTOR
WA UBI No.
602 182 087
Parent company
PATTISON INC
15235 NE 90th Street
REDMOND, WA 98052
425-497-8222
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
PATTIGC917C7
Effective — expiration
02/27/2009— 02/27/2015
Bond
FIRST NAT INS CORP
Bond account no.
6519060
$12,000.00
Received by L&I Effective date
02/20/2008 02/27/2009
Expiration date
Until Canceled
Insurance
Continental Western Ins Co $1,000,000.00
Policy no.
CWP6011067
Received by L&I Effective date
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602182087&LIC=PATTIGC917C7&SAW= 09/03/2014