HomeMy WebLinkAboutPermit D14-0265 - 400 BUILDING - BUILDING 2 ADA RESTROOMSBUILDING 2
RESTRROM UPGRADE
400 INDUSTRY DR
D14-0265
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
0223400010
400 INDUSTRY DR
DEVELOPMENT PERMIT
Project Name: BUILDING 2 RESTROOM UPGRADE
Permit Number: D14-0265
Issue Date: 9/30/2014
Permit Expires On: 3/29/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
BLUE DOG PROPERTIES TRUST
PO BOX 847 C/O THOMSON REUTERS
PTS, CARLSBAD, WA, 92018
KIP KOLODZIEJSKI
1326 FIFTH AVE, SUITE 400 , SEATTLE,
WA, 98101
ELLSWORTH BUILDERS INC
Phone: (206) 587-7120
Phone: (425) 482-2904
8425 219 ST SE, SUITE 100 ,
WOODINVILLE, WA, 98072
ELLSWBI099CF Expiration Date: 2/14/2016
SELF FUNDED - SKB
Address: 617 INDUSTRY DR , TUKWILA, WA,
98188
DESCRIPTION OF WORK:
PROJECT UPDATES RESTROOMS TO ADA RESTROOMS AND REMOVES VESTIBULE WITH EGRESS ISSUES FROM
EXISTING BUILDING
Project Valuation: $25,000.00
Type of Fire Protection: Sprinklers: NO
Fire Alarm: NO
Type of Construction: VB
Fees Collected: $991.02
Occupancy per IBC: B
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2014
2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
Permit Center Authorized Signature:
hearby certify that I have read and e
provisions of law and ordinances gove
amine
ing t
Date:
this permit and know the same to be true and correct. All
s work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: /
Print Name: �� / ' y2
Date: ?,30/%Y
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for
nonstructural components. ASCE 7, Chapter 13.
5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall
be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay
bracing.
6: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
7: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles
shall be ventilated in accordance with the applicable provisions of the International Mechanical Code.
10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
21: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all
purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC
906.3) (NFPA 10, 5.4)
15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40
pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-
held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that
its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the
bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC
906.9)
16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and
immediately available for use. These locations shall be along normal paths of travel, unless the fire code
official determines that the hazard posed indicates the need for placement away from normal paths of
travel. (IFC 906.5)
17: Maintain fire extinguisher coverage throughout.
23: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or
partitions may require relocating and/or adding automatic fire detectors.
19: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may
require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437)
18: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
24: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE FINAL
0409 FRAMING
CITY OF TUKi' .LA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No. 1 14 Q
Project No.
Date Application Accepted: 6'N1)_+-4
Date Application Expires:
For o we use on/
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 022340-0010
Site Address: 400 Industry Dr.
Tenant Name: Building 2 RR upgrade
Suite Number: NA Floor: 1
PROPERTY OWNER
Name: SKB
Address: 617 Industry Dr
City: Tukwila
State: WA
Zip: 98188
CONTACT PERSON — person receiving all project
communication
Name: Kip Kolodziejski
Address: 1326 5th Ave. #400
City: Seattle State: WA Zip: 98101
Phone: (206) 587-7120 Fax:
Email: kipk@burgessdesign.net
GENERAL CONTRACTOR INFORMATION
Company Name: Ellsworth Builders
Address: 8425 219th SE #100
City: Woodinville State: WA Zip: 98072
Phone: (425) 482-2904 Fax:
Contr Reg No.: ELLWB 1099CF Exp Date:
Tukwila Business License No.:
H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 l.docx
Revised: August 2011
bh
New Tenant: ❑ Yes m ..No
ARCHITECT OF RECORD
Company Name: Burgess Design
Architect Name: Kip Kolodziejski
Address: 1326 5th Ave. #400
City: Seattle State: WA
Zip: 98101
Phone: (206) 587-7120 Fax:
Email: kipk@burgessdesign.net
ENGINEER OF RECORD
Company Name: NA
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: Self financed by landlord
Address:
City: State: Zip:
Page 1 of 4
BUILDING PERMIT INFORMATI(. - 206-431-3670
Valuation of Project (contractor's bid price): $ 25 000 Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
Project updates restrooms to ADA restrooms and removes vestibule with egress issues from existing building.
Will there be new rack storage? ❑ Yes
O.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
l' Floor
14,241
200
0
0
VB
B
2nd Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: ' 30 Compact:
0
Handicap: 2
Will there be a change in use? ❑ Yes EI No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm • None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplications\Forms-Applications On Line t201 I Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 2 of 4
PUBLIC WORKS PERMIT INFC IIATION — 206-433-0179
Scope of Work (please provide detailed information):
None, building recently upgraded the backflow device on this building.
Ca11 before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑ ... Water District # 125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certificate
0 .. Highline
❑...Valley View 0 .. Renton
❑...Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Septic System:
O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
0 ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage)
0 ...Bond ❑ .. Insurance 0 .. Easement(s)
Proposed Activities (mark boxes that apply):
O ...Right-of-way Use - Nonprofit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance
O ...Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way 0
❑ ...Total Cut
0 ...Total Fill
cubic yards
cubic yards
❑ .. Geotechnical Report
El .. Maintenance Agreement(s)
❑ ...Traffic Impact Analysis
❑ ...Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor
❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization
❑ ...Frontage Improvements 0 .. Pavement Cut ❑ .. Trench Excavation
O ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ ...Permanent Water Meter Size... " WO #
❑ ...Temporary Water Meter Size .. 55 WO #
❑ ...Water Only Meter Size 55 WO # 0 ...Deduct Water Meter Size
❑ ...Sewer Main Extension Public 0 Private 0
❑ ...Water Main Extension Public 0 Private 0
75
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
0 ...Water 0 ...Sewer 0 ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:
City
State Zip
Day Telephone:
City
State Zip
H:Wpplications\Forms-Applications On Line \2011 Applications\Pemit Application Revised - 8-9-I l.docx
Revised: August 2011
bh
Page 3 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR UTHO ZED AGENT:
Signature: y/
Date: B 41.144
Print Name: Kip Kolo s z' ski Day Telephone: (206) 587-7120
Mailing Address: 1326 5th Ave #400
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx
Revised: August 2011
bh
Seattle WA 98101
City State Zip
Page 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY
PAID
$613.82
D14-0265 Address: 400 INDUSTRY DR
Apn: 0223400010
$613.82
DEVELOPMENT
$584.80
PERMIT FEE
R000.322.100.00.00
0.00
$580.30
WASHINGTON STATE SURCHARGE
8640.237.114
0.00
$4.50
TECHNOLOGY FEE
$29.02
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R3185
R000.322.900.04.00 0.00
$29.02
$613.82
Date Paid: Tuesday, September 30, 2014
Paid By: ELLSWORTH BUILDERS, INC.
Pay Method: CHECK 20312
Printed: Tuesday, September 30, 2014 8:44 AM 1 of 1
CRWSYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT
QUANTITY PAID
PermitTRAK
$377.20
D14-0265 Address: 400 INDUSTRY DR Apn: 0223400010
$377.20
DEVELOPMENT
$377.20
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R2849
R000.345.830.00.00
0.00
$377.20
$377.20
Date Paid: Tuesday, August 12, 2014
Paid By: BURGESS DESIGN INC
Pay Method: CHECK 013175
Printed: Tuesday, August 12, 2014 4:16 PM 1 of 1
CRISYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 436-9350
Project(
f CST c
J h
Type of Inspection:i
1!),.., , i a.. A-e, 1"--) f% 4.,r \
Address: /
4,00
Date Called:
,--
Special Instructions:
..t..
/
Date Wanted:
i 1 -
i / -- K 3-114p.rn.
'Requester:
Phone No:
ElApproyed per applicable codes.
LJCorrections required prior to approval.
COMMENTS:
f (A) 11A. Ot rt('
Inspector'
Date:
I - 11-14:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection,
Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
jai y-- Cz is '
Project:
r .-,5 i..E �+ r J/16_,e,4 6)�
Type_ of Inspection:
I �A 14 ,.-)
C.
Address:
'116C)..1.,c.%()/-/.,'-/ I
Date Called:
Special Instructions:
Date anted:
)/�
a.m.
Requester: I
Phone No:
®Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Inspec or:
ri INSPECTION FEE REQUIRED. Prior to next inspection, fee must be
baid at 6300 Southcenter Blvd., Suite 1d0. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
,r_( stivot1 11}(/Ors
Type ofinspection:
+ M,/6
Address: 1
40J ` JS
�
Date Called:
Special Instructions:
�\
Lj, 0�A1 l
l
Date Wanted:
iI-I"7-2
a.m.
ups
Requester:
Phone No:
.0 Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
A Y
p- . l�n r eSIT > ,> M c - AM N\ fk .1 r)` J P.S
,4:7\A , P ( $(Q .S,, ai\(u rt) _CI Jr
Inspecttor:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NUMBER
fti
— ()Z 6d
24,
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: /`,"'O,e
,�,
i,�L �
/1
Type of Inspection:
p
,4
Address: ".
Suite #: 1
_ �
, (? f
()
-
Contact Person:
Special Instructions:
r
Phone No.:
MApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
A id-
/6-: 6-4-t,),K. ,
4 ---1,-
S- 7?"--
7:1e'4
;
—
- --)
— A is----5-.)
4/ >c 41‘..k ...11(LA..
i -) rktiCv, A---)
-Pe.
0
i,„11.:
-7)
z.,
,---,
r S
\
-4
- b , A 1 -
- - - AS S
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: y
��?y�
Date: /2,4 -,/,Y
Hrs.:
if
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Address:
Company Name:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
PLAN REVIEWWI'ING SLIP
PERMIT NUMBER: D14-0265 DATE: 08/12/14
PROJECT NAME: BUILDING 2 RESTROOM UPGRADE
SITE ADDRESS: 400 INDUSTRY DR
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
SamiACH1
Building Division w
. w1ft(
Public Works
frock Aix -
Fire Prevention
Structural
CAL uV Olie.I1
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 08/14/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
`lea sae, )4.1
DUE DATE: 09/11/14
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑
ILDING O. ICIAL
APPR*` AL F• ISSUANCE
INITIAL/SI . N
DATE
ELLSWORTH BUILDERS INC
Page 1 of 2
0 Washington State Department of
Labor & Industries
ELLSWORTH BUILDERS INC
Owner or tradesperson
ELLSWORTH, THOMAS ALLEN
Principals
ELLSWORTH, THOMAS ALLEN, PRESIDENT
ELLSWORTH, ANNA L, SECRETARY
(End: 01/08/2014)
Doing business as
ELLSWORTH BUILDERS INC
WA UBI No.
601 283 383
8425 219TH ST SE STE 100TH
WOODINVILLE, WA98072
425-482-2904
KING County
Business type
Corporation
oc\o\qw
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
ELLSWBI099CF
Effective — expiration
02/06/1991— 02/14/2016
Bond
OHIO CAS INS CO
Bond account no.
2917483
Received by L&I
02/14/2002
Insurance
West American Ins Co
Policy no.
BKW52030787
Received by L&I
01/23/2014
$12,000.00
Effective date
02/06/2002
Expiration date
Until Canceled
$1,000,000.00
Effective date
02/06/2013
Expiration date
02/06/2015
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601283383&LIC=ELLSWBI099CF&SAW= 09/30/2014