Loading...
HomeMy WebLinkAboutPermit D14-0265 - 400 BUILDING - BUILDING 2 ADA RESTROOMSBUILDING 2 RESTRROM UPGRADE 400 INDUSTRY DR D14-0265 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0223400010 400 INDUSTRY DR DEVELOPMENT PERMIT Project Name: BUILDING 2 RESTROOM UPGRADE Permit Number: D14-0265 Issue Date: 9/30/2014 Permit Expires On: 3/29/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: BLUE DOG PROPERTIES TRUST PO BOX 847 C/O THOMSON REUTERS PTS, CARLSBAD, WA, 92018 KIP KOLODZIEJSKI 1326 FIFTH AVE, SUITE 400 , SEATTLE, WA, 98101 ELLSWORTH BUILDERS INC Phone: (206) 587-7120 Phone: (425) 482-2904 8425 219 ST SE, SUITE 100 , WOODINVILLE, WA, 98072 ELLSWBI099CF Expiration Date: 2/14/2016 SELF FUNDED - SKB Address: 617 INDUSTRY DR , TUKWILA, WA, 98188 DESCRIPTION OF WORK: PROJECT UPDATES RESTROOMS TO ADA RESTROOMS AND REMOVES VESTIBULE WITH EGRESS ISSUES FROM EXISTING BUILDING Project Valuation: $25,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Fees Collected: $991.02 Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: hearby certify that I have read and e provisions of law and ordinances gove amine ing t Date: this permit and know the same to be true and correct. All s work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: / Print Name: �� / ' y2 Date: ?,30/%Y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 21: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Maintain fire extinguisher coverage throughout. 23: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 19: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 24: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING CITY OF TUKi' .LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1 14 Q Project No. Date Application Accepted: 6'N1)_+-4 Date Application Expires: For o we use on/ CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 022340-0010 Site Address: 400 Industry Dr. Tenant Name: Building 2 RR upgrade Suite Number: NA Floor: 1 PROPERTY OWNER Name: SKB Address: 617 Industry Dr City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Kip Kolodziejski Address: 1326 5th Ave. #400 City: Seattle State: WA Zip: 98101 Phone: (206) 587-7120 Fax: Email: kipk@burgessdesign.net GENERAL CONTRACTOR INFORMATION Company Name: Ellsworth Builders Address: 8425 219th SE #100 City: Woodinville State: WA Zip: 98072 Phone: (425) 482-2904 Fax: Contr Reg No.: ELLWB 1099CF Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 l.docx Revised: August 2011 bh New Tenant: ❑ Yes m ..No ARCHITECT OF RECORD Company Name: Burgess Design Architect Name: Kip Kolodziejski Address: 1326 5th Ave. #400 City: Seattle State: WA Zip: 98101 Phone: (206) 587-7120 Fax: Email: kipk@burgessdesign.net ENGINEER OF RECORD Company Name: NA Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Self financed by landlord Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATI(. - 206-431-3670 Valuation of Project (contractor's bid price): $ 25 000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Project updates restrooms to ADA restrooms and removes vestibule with egress issues from existing building. Will there be new rack storage? ❑ Yes O.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l' Floor 14,241 200 0 0 VB B 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: ' 30 Compact: 0 Handicap: 2 Will there be a change in use? ❑ Yes EI No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm • None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line t201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFC IIATION — 206-433-0179 Scope of Work (please provide detailed information): None, building recently upgraded the backflow device on this building. Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District # 125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑...Valley View 0 .. Renton ❑...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): O ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance O ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut 0 ...Total Fill cubic yards cubic yards ❑ .. Geotechnical Report El .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements 0 .. Pavement Cut ❑ .. Trench Excavation O ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... " WO # ❑ ...Temporary Water Meter Size .. 55 WO # ❑ ...Water Only Meter Size 55 WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 75 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line \2011 Applications\Pemit Application Revised - 8-9-I l.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR UTHO ZED AGENT: Signature: y/ Date: B 41.144 Print Name: Kip Kolo s z' ski Day Telephone: (206) 587-7120 Mailing Address: 1326 5th Ave #400 H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Seattle WA 98101 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $613.82 D14-0265 Address: 400 INDUSTRY DR Apn: 0223400010 $613.82 DEVELOPMENT $584.80 PERMIT FEE R000.322.100.00.00 0.00 $580.30 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $29.02 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3185 R000.322.900.04.00 0.00 $29.02 $613.82 Date Paid: Tuesday, September 30, 2014 Paid By: ELLSWORTH BUILDERS, INC. Pay Method: CHECK 20312 Printed: Tuesday, September 30, 2014 8:44 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $377.20 D14-0265 Address: 400 INDUSTRY DR Apn: 0223400010 $377.20 DEVELOPMENT $377.20 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2849 R000.345.830.00.00 0.00 $377.20 $377.20 Date Paid: Tuesday, August 12, 2014 Paid By: BURGESS DESIGN INC Pay Method: CHECK 013175 Printed: Tuesday, August 12, 2014 4:16 PM 1 of 1 CRISYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 436-9350 Project( f CST c J h Type of Inspection:i 1!),.., , i a.. A-e, 1"--) f% 4.,r \ Address: / 4,00 Date Called: ,-- Special Instructions: ..t.. / Date Wanted: i 1 - i / -- K 3-114p.rn. 'Requester: Phone No: ElApproyed per applicable codes. LJCorrections required prior to approval. COMMENTS: f (A) 11A. Ot rt(' Inspector' Date: I - 11-14: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 jai y-- Cz is ' Project: r .-,5 i..E �+ r J/16_,e,4 6)� Type_ of Inspection: I �A 14 ,.-) C. Address: '116C)..1.,c.%()/-/.,'-/ I Date Called: Special Instructions: Date anted: )/� a.m. Requester: I Phone No: ®Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspec or: ri INSPECTION FEE REQUIRED. Prior to next inspection, fee must be baid at 6300 Southcenter Blvd., Suite 1d0. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ,r_( stivot1 11}(/Ors Type ofinspection: + M,/6 Address: 1 40J ` JS � Date Called: Special Instructions: �\ Lj, 0�A1 l l Date Wanted: iI-I"7-2 a.m. ups Requester: Phone No: .0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: A Y p- . l�n r eSIT > ,> M c - AM N\ fk .1 r)` J P.S ,4:7\A , P ( $(Q .S,, ai\(u rt) _CI Jr Inspecttor: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER fti — ()Z 6d 24, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /`,"'O,e ,�, i,�L � /1 Type of Inspection: p ,4 Address: ". Suite #: 1 _ � , (? f () - Contact Person: Special Instructions: r Phone No.: MApproved per applicable codes. Corrections required prior to approval. COMMENTS: A id- /6-: 6-4-t,),K. , 4 ---1,- S- 7?"-- 7:1e'4 ; — - --) — A is----5-.) 4/ >c 41‘..k ...11(LA.. i -) rktiCv, A---) -Pe. 0 i,„11.: -7) z., ,---, r S \ -4 - b , A 1 - - - - AS S Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: y ��?y� Date: /2,4 -,/,Y Hrs.: if $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PLAN REVIEWWI'ING SLIP PERMIT NUMBER: D14-0265 DATE: 08/12/14 PROJECT NAME: BUILDING 2 RESTROOM UPGRADE SITE ADDRESS: 400 INDUSTRY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: SamiACH1 Building Division w . w1ft( Public Works frock Aix - Fire Prevention Structural CAL uV Olie.I1 Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: `lea sae, )4.1 DUE DATE: 09/11/14 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ ILDING O. ICIAL APPR*` AL F• ISSUANCE INITIAL/SI . N DATE ELLSWORTH BUILDERS INC Page 1 of 2 0 Washington State Department of Labor & Industries ELLSWORTH BUILDERS INC Owner or tradesperson ELLSWORTH, THOMAS ALLEN Principals ELLSWORTH, THOMAS ALLEN, PRESIDENT ELLSWORTH, ANNA L, SECRETARY (End: 01/08/2014) Doing business as ELLSWORTH BUILDERS INC WA UBI No. 601 283 383 8425 219TH ST SE STE 100TH WOODINVILLE, WA98072 425-482-2904 KING County Business type Corporation oc\o\qw License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ELLSWBI099CF Effective — expiration 02/06/1991— 02/14/2016 Bond OHIO CAS INS CO Bond account no. 2917483 Received by L&I 02/14/2002 Insurance West American Ins Co Policy no. BKW52030787 Received by L&I 01/23/2014 $12,000.00 Effective date 02/06/2002 Expiration date Until Canceled $1,000,000.00 Effective date 02/06/2013 Expiration date 02/06/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601283383&LIC=ELLSWBI099CF&SAW= 09/30/2014