Loading...
HomeMy WebLinkAboutPermit D14-0287 - COURTYARD AT SOUTH STATION - TENANT IMPROVEMENTCOURTYARD AT SOUTH STATION 3900 SOUTHCENTER BLVD D15-0287 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0043000170 3900 SOUTHCENTER BLVD Project Name: COURTYARD AT SOUTH STATION Permit Number: D14-0287 Issue Date: 11/14/2014 Permit Expires On: 5/13/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: COURTYARD AT SOUTH STATION 3131 S VAUGHN WAY #301 CO GEOARGE MCELROY & ASSOC, AURORA, WA, 80014 CHRISTINA ROBERTS PO BOX 73516 , PUYALLUP, WA, 98373 FIRST CHOICE REMODELING PO BOX 73516 , PUYALLUP, WA, 98373 FIRSTCR8805B COURTYARD AT SOUTH STATION 3131 S VAUGHN WAY #301 CO GEOARGE MCELROY & ASSOC, AURORA, CO, 80014 Phone: (253) 778-3886 Phone: (253) 507-5353 Expiration Date: 8/2/2016 DESCRIPTION OF WORK: FRAME IN EXISTING PORCH, CREATING BATHROOM, TANNING ROOM AND STORAGE ROOM Project Valuation: $22,960.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $1,711.90 Occupancy per IBC: R-2 Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: rr Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 2: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 3: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 5: Maintain fire extinguisher coverage throughout. 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 10: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 12: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 14: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 15: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 16: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 1400 FIRE FINAL 0201 FOOTING 0200 FOUNDATION WALL 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL 4046 SI-EPDXY/EXP CONC 0602 SLAB/FLOOR INSUL 0601 WALL INSULATION CITY OF TUKWILA Community Development Department Public Works Department Permil Center 6300 Southcenter Blvd, Suite 100 Tukwi/a, WA 98188 http://www."fukwilaWA.gov Building Permit No. 1 1"'1 — a-S7 Project No. Date Application Accepted: Date Application Expires: S (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION c,, `�� King Co Assessor's Tax No.: O 01170 Site Address: 1 W So31+1 CpJ4tle�C�``',,1Bt._ Suite Number: Floor: Tenant Name: OW\-\ frkYG' �� Sc»k 'Tahoe) New Tenant: El Yes ..No PROPERTY OWNER CYName:6 .n0ge yiCIay C, ,6550 c Address: 3131S V11Nhw01, City: State: Zip: CONTACT PERSON - person receiving all project communication Name:Nyishiel ea;€1,4:5- A dd ress: 0,01( .-1.�y) Le City: J g 1 j U e State: tAfit Zip 7 ,73 Phone:2 27783d a[.p ax; .3 �� 4q' ! Email: '-'1K%-CJwtcerPnNodel t0otma: [. Cu 1 GENERAL CONTRACTOR INFORMATION Company Name: t..., i I Ana . I Address -2D6x51 Lp City: n ` oyc,Itk3P State: wpv Zip:eN.37.11 Phone:2 x- 5353 Fax: 2S3 5'o)`� J:l2U� i I'1sot Contr Reg No. Y`J4_C12.� .>�Exp Date: 4 Tukwila Business License No.: 6 11L/1 ARCHITECT OF RECORD Company Name: rnit1014 4-,1SSO CCI" e _ rr 4o R- Architect Name: ICC::4Y\Ck KA. A ddress:7O1_ 4a S4 ,2& City: ��I/�OtI,1� State: �/� Zip: L,^� ��� �`Ll/�0 7�- Phone: r„ i`i�i ax:2S. 6(03 Email: Ib eiVrlhA - ( C1/401 • Can ENGINEER OF RECORD Company Name: Engineer Name:t►-�e 5• r'rl(_ �y r 1 L I�� Address:14 245 S.14-1-k AtFeS City: l�vt411 �l State: �, Z.ip(�,� 1'honeOlbb6 2 '1r _, _w5 1 ax: Email: LENDER/BONI) ISSUED (required for projects $5.000 or 19.27.095) greater per RCp. Name: � CCW ,,'',,-- // Cv'-kjtrd GtI- )A-h Address: City: State: Zip: 1-171Applications\porno-Applications On Line1201 1 ApplicationsiPcrtnn Application Rev ised - 8-9-11.doc.. Revised: August 2011 hh I'agc I of4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ Z2 .1(00 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ 'runes L1-) xtsh'rt poYc - - d,& ,khmar, c ,n( „c1,61/4 1mcu e4evia ce S -c{ Will there be new rack storage? ❑ Yes �.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 151 Floor i I 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling. provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows thatthe principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: N() ( Q. ik .c C k Compact: Handicap: Will there be a change in use? Yes ❑ No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm Qo►kin LerASInci 6 S c- None ❑ Other (specify) Will there be storage or use of flammable. combustible or hazardous materials in the building? ❑ Yes Mj No If "yes', attach list of materials and storage locations on a separate 8-1/2- x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM O On -site Septic System — For on -site septic system. provide 2 copies of a cun•ent septic design approved by King County I lealth Department. H:\Applications\forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.doc Resised: August 21111 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ .. Renton ❑ ...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that applv): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ... H old Harmless — (SAO) El ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... ,• WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\201 1 Applications\Permit Application Revised - 8-9-11.docx Revised: August 20] 1 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING NER O AUTHOR] AG Signature: Print Name: x..� l ' hs fi ►nC( 0.rT� Mailing Address:4)0 tax % 51(p Date: 02.01L/ Day Telephone: 253 7) cE TI`-'rtt /873 CityState Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 Ldocc Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $1,360.18 D14-0287 Address: 3900 SOUTHCENTER BLVD Apn: 0043000170 $1,360.18 DEVELOPMENT $545.60 PERMIT FEE R000.322.100.00.00 0.00 $541.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 IMPACT FEE $787.52 FIRE R304.345.852.00.00 0.00 $519.68 PARK R104.345.851.00.00 0.00 $267.84 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3560 R000.322.900.04.00 0.00 $27.06 $1,360.18 Date Paid: Friday, November 14, 2014 Paid By: FIRST CHOICE REMODELING Pay Method: CHECK 3171 Printed: Friday, November 14, 2014 10:03 AM 1 of 1 rL1 LJ V SYSTEMS Cash Register Receipt City of Tukwila Receipt Number R2980 DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $351.72 D14-0287 Address: 3900 SOUTHCENTERBLVD Apn: 0043000 70 $351.72 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2980 R000.345.830.00.00 0.00 $351.72 $351.72 $351.72 Date Paid: Tuesday, September 02, 2014 Paid By: FIRST CHOICE REMODELING INC Pay Method: CHECK 3154 Printed: Tuesday, September 02, 2014 11:38 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P1Y-02-87 Project: a fr ( LU'-frCt Pti&fat5fiT/Y011 o. .i Type ogrgcti( Kg I Address: 3 Too .k-ufik_c_lvtitid Date Called:I Special Instructions: phi Date Wanted: s---5---- (3' a.m. p.m. 'Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date5—ircIS—' E REINSPECT! N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Btvd., Suite 100. Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Dly- 02437 Project: i t LO Cir flak/ 0 j7D itaftiii Type of 1%spectio: r / 6 tor r(ptcz i 'Address: WOO SO dr, 6 (tic/ Date Cal ci: Special Instructions: 4-4 Date Wanted:____ 3 .- z-r— 0— a.m. P•m• 'Requester: Phone No: 0 Approved per applicable codes. 34 Corrections required prior to approval. COMMENTS: frc, C. ro- LA -Fo €_,(e6{4,--cei I ( t 1p Fc,(1-(JA ( et/"Valicit Crfo.1(kKi, t> ( f ' ife-Vitrue. t.,--L Fit-- ( i c-€. halc-Ete---r qt 3 1 ci ( r s pc? -f- c.4A.vel if . ' lie.a/L‘f-e Ceft I , v-e_il-t-s-re4/ ok 7S--frilvt (a_j( cfrv. }J/A 6(4 '.. /Ay nspector: r r Date:3 Lys_ 5_ f- RENSPETION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. 071g7 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., *100, Tukvvila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A la vd4 Type of Inspectiop: ,t-utcx I Address: i I 194e) cr,tt 14 ("PA kr g/V d Date Called: , 'Special -Instructions: Date Wanted: a.m. Requester: Phone No: EjApproved per applicable codes. Corrections required prior to approval. COMMENTS: ( ( ik0 ( MO4-- C IC-- frail, WV f• , (s.,..„,:,, , iii,, 0 . L., / (": / ie- ,.....i * r rail •r ve rfrk501e-c-1- 1 Oil --- t ( sk . i Inspectordir...:c„, Date:/ _30 ( 5_ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD INSPE TIQN NO. Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: \' Mk J8l1d4 if (-4ttiknJ Type of Inspection: f,A,)A If -".�Su A+; 4 .....:.... Address: ` 3-► 00 L1 kC \*I t3 ( J Date Called: Special Instructions: Date Wanted: t 2 I a e._ 1/1--k 6rt' P.m. Requester: Phone No: EApprovedper applicable codes. Corrections required prior to approval. COMMENTS: Inspector ! r Atv $-1 1 l 1('4. AjQ•-A-/1 �j'REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be 1pai/d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. -Date: / 4i 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. , CITY OF TUKWILA BUILDING DIVISION 4.1 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 , Permit Inspection Request Line (206) 438-9350 OA -61Vr7 Project: Type Of-Inspecton:11Sit\ Date Called: / Addcess: 31 00 S4- 1- kik. Special Instructions: Date Wanted: (1 p.m'. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. tr- COMMENTS: (.4 J Li" (-__)(T--efs ir ki\-) US — He( IMA-1\ Ster P/A , .(i a p‘trio AA,I,c-r- IAA\ )c c: re. gi alAr p MA\ tA);(- eS k,,,pjl, 1 0 ' ‘A 91'. -?---f•t- Pr -it 1 ' -T) J NI 37 G---D U EJ 1' t e (—Cr.( k-k T ) 0X, NA, 11A ‘, \ A \ 111 ee-A/ ,1/4 A IN r"-)VPA I 1 r; e 5 i ti i r \ .0 J I 47T- . ,) A ( _,) c_'—ut, , i ins char Date:fIA REINSPECTION FEE REQUIRED:Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, ) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 6-64.) r I Li i Q 5 ,., Type of Inspection: ./ A_ . 1-11,,N E , A Aef 'Addre 2 / 3Uto Sc 8Wek . Date Called: 4 Special Instructions: 3 ,c7 %.J\tlk S' -. • .94 ('one Date Wanted: i Requester: No: cv r ' ttl -1-'p I A S ( o i A c---.... 123 Approved per applicable codes. Corrections required prior to approval. COMMENTS: T-e, ---C1,-) o f) kr( ‘2,--TAA 4-A,' L 1 \ e„,s _ (A e_A-1V tAjiC N\ 0, 0 6 )-r.,,N,4 -(-1) i NSUPA-\:0 A n - ....--- ---, , N xo re 0 \ • _ _ _____ - ' I Inspictor - 5 —14 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. .1) 4 Z-Y1 INSPIOW NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Project; -Type —,---, i r-r-, Ar (., a .5. I Avi . iki of Inspection: r-,A iit, ( ,/- 4o, Address: i -9tOin Se_ Date ailed: Special Instructions: 7 -,-- Date Wanted:VZ---- / q ' 14 e."..m. ;.P-7‹ Requester: Phone No; ErApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Datei 2 q- 14 ri REINSPECTIDN FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: QZ+ r `F �' f r' S 4 I - 54.11 li 4.1 Type Qf Inspection: A- \ -j t ✓ €.. , rt) Address: 35 ba Suite #: S. (v� Contact Person: Special Instructions: Phone No.: _Appr`oved per applicable codes. Corrections required prior to approval. COMMENTS: c; f e .C70 veer - <l e r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: &% �,,. ce_9____ Date: s/a c�// -- -Hrs.: tt/V•v f/ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER adrs-7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-44 Project: Cr t tekr2- 9 0 Se. '0+� Ty a of Ins ction: v, .v tA4- r4 Address: 0 Suite #: .� d C. 1 U� Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: r 2 -I rL t 1,5k Cod( fib- sus= y907 Needs Shift Inspection: Sprinklers: Fire Alarm: - Hood & Duct: Monitor: Pre -Fire: Permits: - Occupancy Type: Inspector: Date 21.2// .$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billin 9 Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Y f-E3 V V Y u to av gagyagualoabaltuin dE[. tiANDRnmtli.0jjii c QyruT ttc�mmn1tslaav li. Canada ABIAY oc t, 04*stem , C•iREM paW e.i' entatl e. 1 r - j co..: COPI.., PLIANCE i NOV 0.i2014 oily of BUILI.JIN .\IIS;O bloz87 DECEIVED CITY OF TUKWILA OCT 2 8 2011 PERMIT CENTER • 04 T▪ ot or Tao itiocU ,1•t %T ocit 3 maraw 1.1. I11ay Z; 3%L r ,E+Gii.lirt ccsitJ61 YL10 301 *lel•%S ft.r.i k Aft tli[1 Li'Ui aiglin409) / • • . 41he n Iinfa0 i ullrNlitkl g'AiliGJ L4.11914 fi7 DikleiR Ail Ljfi.za ( IiT- i JJri u lt_.Y• X ii Y iirc .]qr..-.m4 1,? Una%j Irze„ s Ash e 7 [gO101Nrinp5l` Wirt I+t! 121m Igo') .1,,taibW7Y..J G1�( 0J�' gip c4jc4ge4 firri.[:Jii 1L4y fit (C1.ililf' ! kxyueji ItEL ru I .Yi 01k9P gOliff Aff.1 31). 21 iiNlt3YYlsO &vi EUIVAM, IIL, atu !100 &Ma goloot7Ui'k 411iwi IArolitiox,' email tit:1irogyilgort bui Jm1i 1•0 IRO z>z7y, neu.) guild go aoottlei it iv i4hrogiviNtor.vg9 4l4i go l)K R i iJ,1kL•!.0 lWF3 earot 'Q *17., 4rli?.4i rsookait iitur? Yi roakL.rtlrr+i ?._ r glo us, lam, IRA � 1 17 7 tom) ngiUir•J%1/ Y313r;C. , 9itw ul]Lii nC]k'ilai;g ; 1% (igo ni edidigq [egglia, .e rili+•r aL•1r) ;r irlty �litT u.Z.Q:a7c7k�, [ u .0LelM .w L = • , A- t-snlAY IunsA Fiat Ila, .., S.] .' ' �''_ til.A / -•7'lpcorger, p, iYi gAT40 `xYiiM M 0103 VJiii i 'O `0:10 .m wan) 1ii uiilEvcoA, QiIiim QiFsietik, ITaL ET I� • i • i Index Applications 2 Features 3 Functions 4-6 Trim Designs 7 Options & Accessories 8-9 How to Order 10 Quick Codes 11-12 How to Specify 13 An economical, Grade 2 standard -duty lever lockset which provides an outstanding combination of value and performance. It's the ideal lever lockset for standard commercial applications. When used in conjunction with the CL3300 Series Extra Heavy -Duty Grade 1 and the CL3500 Series Heavy -Duty Grade 1 Cylindrical Lever Locksets, the overall cost of many projects may be reduced without compromising functionality and durability. BIWA onommi LS. Typical applications include: • Interior offices • Closets • Multi -family housing • Restaurants • Retail complexes Advantages • Lever Release" for vandal resistance • Solid cast levers • ANSI/BHMA Grade 2 certification • UL-cUL 3-hour fire rating • Independent lever return springs • Through -bolts on door for solid attachment • Covers ANSI/BHMA door prep A156.115 CL3800.2 ASSA ABLOY, the global leader in door opening solutions 45355-3/14 Features Handing Non -handed. Door Thickness Adjustment Standard 1-3/8" to 1-3/4" (35 to 45mm); factory set for 1-3/4" doors. For 2" (51 mm) and 2-1/4" (57mm) doors, specify door thickness. See Quick Codes, page 11-12. Lock Chassis Steel, zinc dichromated for corrosion resistance. Backset 2-3/4" (70mm) standard. Optional: 2-3/8" (60mm), 3-3/4" (95mm) and 5" (127). See Quick Codes, page 11-12. Latchbolt 1/2" (13mm) throw latch with universal "floating" front to fit both flat and beveled doors. 2-1/4" x 1-1/8" (57 x 29mm) square corner front for 2-3/4" (70mm) backset standard. For other latch options, See Quick Codes, page 11-12. Auxiliary Latchbolt Deadlocking latchbolt prevents manipulation when door is closed. Strike ANSI curved lip strike standard, 4-7/8" x 1-1/4" x 1-1/4" (124 x 32 x 32mm) lip to center. Optional strikes, lip lengths and ANSI wrought strike box available; See Quick Codes, page 11-12. Cylinder Brass, 6-pin, L4 keyway, "0" bitted standard. Keying Features Available Conventional 6-pin Conventional 7-pin Master keying Construction master keying Visual key control Concealed key control Pyramid' Security Pyramid High Security Interchangeable core (IC) Security Security IC Pyramid Security IC Pyramid High Security IC Access 3® Keys Two nickel silver standard. Warranty Seven-year limited. Through -bolts prevent chassis rotation; ensure proper alignment, smooth operation and long life 1/2" throw latchbolt accommodates 7/8" and 1" edge bore preps 2-3/8", 2-3/4", 3-3/4" and 5" backsets available Certification/Compliance ANSI/BHMA Certified meets A156.2 Series 4000, Grade 2. Meets Al 17.1 Accessibility Code. Federal Meets FF-H-106C. California State Reference Code (Formerly Title 19, California State Fire Marshal Standard) All levers with returns comply; levers return to within 1/2" of door face. UL-cUL All locks listed for "A" label single doors. Letter "F" and UL symbol on latch front indicate listing. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin, Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire -rated opening, or specifying and installing a new fire -rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. Solid cast levers with no plastic inserts Lever designs compatible with Corbin Russwin Mortise Locks, Exit Devices and other Lever Locksets Non -handed spring cassette prevents lever sag Lever release design for vandal resistance ASSA ABLOY, the global leader in door opening solutions CL3800.3 45355-3/14 ti CL3810 CL3820 CL3832 CL3840 Passage or Closet Privacy Bedroom or Bathroom Institutional or Utility Patio or Privacy F75 • Latchbolt by lever either side • Both levers always free. • Throw -off latchbolt by lever either side, except when push button locks outside lever. (Lever handle is free -wheeling in locked position.) F766 • Outside lever locked by push button. (Lever handle is free -wheeling in locked position.) • Outside lever unlocked by emergency release tool, by rotating inside lever or by closing door. • Inside lever always free. F87 • Deadlocking latchbolt by key either side. (Lever handle is free- wheeling in locked position.) • Throw -off latchbolt by lever either side except when push button locks outside lever. (Lever handle is free -wheeling in locked position.) F77 • Outside lever locked by push button. • Outside lever unlocked by rotating inside lever or by closing door. • Inside lever always free. • Should not be used in rooms that have no other entrance. • Deadlocking latchbolt by lever inside. CL384ONT Exit Latch F89 • Outside lever always locked. (Lever handle is free -wheeling.) • Inside lever always free. • Should not be used in rooms with no other entrance. CL3850 Half Dummy Trim • Lever acts as pull only; no operation. • Lever is rigid. • Deadlocking latchbolt by lever either side except when turn button locks outside lever. (Lever handle is free -wheeling in locked position). Pushing turn button locks outside lever, requiring use of key outside to unlock. CL3851 Entrance F109 • Turning inside lever unlocks outside lever. or Office • Pushing in and turning button locks outside lever, requiring key at all times. Turning inside lever does not unlock outside lever until button is manually turned to unlocked position. • Turning inside lever unlocks outside lever. • Inside lever always free. CL3800.4 ASSAABLOY, the global leader in door opening solutions 45355-3/14 Russwin fi ASSAABLOY Functions Outside Series/Function I coo Ea Function Description CL3800 • Deadlocking latchbolt by lever either side except when key outside locks outside lever. (Lever handle is free -wheeling in locked CL3855 Classroom F84 position.) • Outside lever unlocked by key outside. • Inside lever always free. CL3857 Storeroom or Closet • Deadlocking latchbolt by key in outside lever or by rotating inside lever. F86 • Outside lever always locked (lever handle is free -wheeling in locked position). • Inside lever always free. • Deadlocking latchbolt by lever either side, except when push button locks outside lever. CL3861 Entry F82 • Push button released by turning inside lever or by key in outside or Office lever. (Lever handle is free -wheeling in locked position.) • Closing door does not release push button. • Inside lever always free. • Deadlocking latchbolt by lever either side except when key in either lever locks or unlocks the lever independently of the other. (Lever CL3862 Communicating F80 handle is free -wheeling in locked position.) • Should be used only in office or rooms with multiple entries. • Keyed alike unless otherwise specified. CL3870 CL3872 CL3880 Full Dummy Trim Apartment, Exit or Public Toilet Passage Lever x Blank Plate • Levers act as pulls only; no operation. • Levers are rigid. • Deadlocking latchbolt by lever either side, except when key inside locks outside lever. (Lever handle is free -wheeling in locked position.) F88 • Key outside retracts latchbolt. • Key inside unlocks outside lever. • Inside lever always free. • Keyed alike unless otherwise specified. F111 • Deadlocking latchbolt by lever. • Lever on one side; blank plate on the other. • Lever always free. • For single or double communicating doors. ASSA ABLOY, the global leader in door opening solutions C L3800.5 45355-3/14 Russrwm • ASSA ABLOY Functions CL3800 Outside Series/Function r • Amy Function Description CL3881 Keyed Lever x Blank Plate • Deadlocking latchbolt by lever except when key locks lever (lever F113 handle is free -wheeling in locked position). • Lever on one side; blank plate on other side. • Key unlocks lever. Passage • Latchbolt by lever or by turnpiece. CL3890 Lever x — • Lever on one side; turnpiece on other side. Turnpiece • Lever and turnpiece always free. • Deadlocking latchbolt by lever except when key locks lever. (Lever handle is free -wheeling in locked position.) Keyed • When lever is locked, latchbolt is operated by turnpiece. (Lever CL3891 Lever x handle is free -wheeling in locked position.) Turnpiece • Lever on outside; turnpiece on inside. • Turnpiece always free. • Key unlocks lever. CL3893 Service Station • Throw -off latchbolt by lever, dosing door, or by turning inside lever. • Outside lever locked by slotted push button. (Lever handle is free -wheeling in locked position.) • When slotted push button is pushed in and turned, outside lever F92 becomes free -wheeling and deadlocking latch is activated. Key outside retracts latch. • Turning inside lever does not unlock outside lever until button is manually turned to unlocked position. • Inside lever always free. CL3800.6 ASSA ABLOY, the global leader in door opening solutions 45355-3/14 Armstrong AZD Lever: Die-cast zinc Rose: Wrought brass or bronze Newport Complies with codes requiring lever to return to within 1/2" (13mm) of door face. NZD Lever: Die-cast zinc Rose: Wrought brass or bronze Princeton Complies with codes requiring lever to return to within 1/2" (13mm) of door face. PZD Lever: Die-cast zinc Rose: Wrought brass or bronze 2-13/16" ASSA ABLOY, the global leader in door opening solutions 45355-3/14 CL3800.7 Rus°swin l ASSA ABLOY Options & Accessories CL3800 Latches To order optional latchbolt with lockset, see How to Order, page 10. To order latchbolt separately, specify Part No. x Finish (e.g., 599F91 x 626). 2-3/8" Backset 2-3/4' Backset 3-3/4' Backset 5" Backset 1" width, square corner 1" width, rounded corner 1-1/8" width, square corner 1-1/8' width, rounded corner 1" width, square corner 1° width, rounded corner 1-1/8' width, square corner 1-1/8° width, rounded corner 1-1/8" width, square corner 1-1/8' width, rounded corner 1-1/8" width, square corner 1-1/8' width, rounded corner 599F92 599F95 599F98 , 600F01 600F04 600F07 600F10 600F13 600F63 600F66 600F69 600F71 600F72 Housing diameter 7/8° for all models. 1" diameter latch sleeve furnished with each latchbolt. Cylinders 599F91 599F94 599F97 600F00 600F03 600F06 600F09 600F12 600F62 600F65 600F68 Standard Cylinder 3'' rbi Jcu�xit„ _ ;i�arf u _4Vit' pll.01e) ilauuttaf i�rtuutl _ . tt&: , i:} yn1 _']'l�idyal ]11�Aaf 'k 1•zxiit ; tifk, V4 599F93 599F96 599F99 600F02 600F05 600F08 600F11 600F14 600F64 600F67 600F70 600F73 Plain Deadlocking (CL3810) (All other functions) Interc angeable IgaG Ott _i]::➢,lt:too ,c zuw. A?.rte7't ]' 3� ' Ir]hlJ iG atittaf lx tc.atikq 4.1A , .cJplivaia! IP,youmul L•ttix�,,31fuu iyetdt01,1ilriJiI$ fs 11U'r6tv.. 4*34, 70m, t 1, fill 1" i?l,+'% Conventional Security Pyramid High Security Pyramid Security Access 3° AP Access 3° AS Access 3° AHS Schlage° C Keyway Sargent° LA Keyway 6-pin 7-pin 6-pin 7-pin 7-pin 6-pin 6-pin 6-pin 6-pin 6-pin 2000-033 (standard) 2000-033-7 2010-033 2020-033 2027-033 2500-033 2600-033 2700-033 2400-033-C 2400-033-LA To order optional cylinder with lockset, see How o Order, page 10. To order cylinder separately, specify Part No. x Keyway x Finish (e.g., 8000 x L4 x 626). Compatibility with Competitive Cylinders Schlage conventional 21-002, 23-001 or 23-013 Schlage Primus 20-548, 20-550, 20-748 or 20-750 Schlage 6-pin Interchangeable Core SFIC style core, 6 or 7-pin Sargent 13-3266 8000 8000-7 8010 8020 8027 8500 8600 8700 682F398 tailpiece included with M06 option. 682F398 tailpiece included with M06 option. Specify M69 - 697F942 Tailpiece included with M69 option. 682F95-8 tailpiece kit and special lever (NZD and PZD designs only) included with M08 option. Accommodates 6 and 7-pin cores. Throw -Off (CL3820, CL3893 & CL3840) 599F38-9 Tailpiece kit and special lever. Included with M09 options. See How to Order, page 10. For Assa° and Medecoe retrofit cylinders, consult those manufacturers' catalogs. CL3800.8 ASSAABLOY, the global leader in door opening solutions 45355-3/14 Russet n /i ASSA ABLOY Options & Accessories Strikes (10) 1/4° Radius Corners (25mm) 2-1/4" (57) 1-5/8° (41) ANSI Curved Lip (standard) Brass or stainless steel. 4-7/8" x 1-1/4" x 1-1/4" lip to center. Optional hp lengths: 1 ", 1-1/8", 1-3/8", 1-12", 1-3/4", 2", 2-1/4", 2-1/2", 2-3/4", 3". To order separately, specify 217L13 x Lip Length x Finish. Rabbeted Front and Strike Brass or bronze. 4" x 5/8" for 1/2" rabbet. No optional lip lengths. To order with lockset, specify quick code found on pages 11. To order separately, specify 601 F28 x Finish. Full Lip Strike Brass or stainless steel. 2-1/4" x 1-3/4" x 1-1/4" lip to center. No optional lip lengths. To order with lockset, specify quick code found on pages 11. To order separately specify 680L50M020 x Finish. Anti -rattle tab. Full Lip Strike — 1/4" Radius Corners Brass or stainless steel. Similar in dimension and function to L50 strike (above) but with radius corners for easy mortising by power tools. To order with lockset, specify quick code found on pages 11. To order separately specify 680L51 M020 x Finish. Anti -rattle tab. 1 CL3800 Curved Lip "T" StrikeBrass. 2-3/4" x 1-1/8" x 1-1/4" lip to center. Optional lip lengths: 1", 1-1/8", 1-3/8", 1-1/2", 1-3/4", 2", 2-1/4", 2-12", 2-3/4", 3". To order with lockset, specify quick code found on pages 11. To order separately, specify 586L19 x Lip Length x Finish. ANSI Wrought Strike Box To order with lockset, specify quick code found on page 12. To order separately, specify 120F768. ASSAABLOY, the global leader in door opening solutions CL3800:9 45355-3/14 Ordering Examples LH LeTt Harrel LHR Re,;e Stock Order : urnti y n -y1Guhrsobor-D I rrnirrl i ri�n] ' Ink7nyJ 100 CL3855 NZD 626 RHR Split Trim / Finish Order RH Rs:`t Han( RHR j IIL � LxS� irimN l YVC]'J�fd j qua Zit/ rlXr`t;6nn Ji o t k� l� ami ) i gam 1 12 CL3855 NZD AZD 626 625 RH Contract/ Detailed Order [ o�urrl y it y j 1 i 1Pfur� Ift 24 AA1 CL3855 NZD Where to find ordering information and quick codes Series/Function Pages 4-6 Trim Designs Page 7 Finish Page 11 Door Thickness Page 11 Backset Page 11 Strike Page 11 Cylinders and Keying Page 11 Miscellaneous Options Page 12 iFwbhlurno Door i d' ir6 �Jucr J I � � ��:is:��s II �riiiu><Irll�s � L li!r1 5? o o SI/clf'A3 626 RHR D214 B238 SC114 M17 0; PHS 1 J CKC2 C L3800.10 ASSA ABLOY, the global leader in door opening solutions 45355-3/14 Russwin ri `Access 3® AHS IC Pyramid High Security Fixed Core Pyramid High Security IC 0 ASSA ABLOY Quick Codes Cylinder and Keying Conventional 6-pin Conventional 7-pin Less cylinder(s) MSpecify� (standard) 7p 1 LC T-_1 —PHS _ - _ PCHS J Pyramid IC Less Core CLP Pyramid with temporary construction core Pyramid Security Fixed Core [-Pyramid-Security-IC- Pyramid Disposable Core L6_Pin Disposable Core 7-Pin_ Disposable Core _ O bbitted with-2- blank_ keys Keyed random y `Construction master keyed Visual key control (VKC) _ ! No bitting or keyset stamping on keys _ _Keys only Cylinders and keys (not for HS, CHS, 1 PHS, PCHS or Access 3e) _= 1 , IC 6-pin- C6 IC 6-pin with Temporary Construction Core (Red) _1 CT6R_ I IC 6-pin with Temporary Construction Core (Blue) CT6B- IC 6-pin with Temporary Construction Core (Green) 1 CT6G r IC 6-pin with temporary construction core_ CT6 _ _ IC 6-pin less core _ _ _ r CL6 _ r SFIC_6 or 7-pin Small Format Disposable Core CTSD , IC 7-pin r C7 __ , [IC 7-pin less core _ -- - CL7 IC 7-pin with temporary construction core _ _ _ j — CT7 _ _ [IC 7-pin with Temporary Construction Core (Red) _ CT7R IC 7-pin with Temporary Construction Core (Blue) I CT7B IC 7-pin with Temporary Construction_ Core (Green) CT7G , Security _ _ _ . - - L HS _Security IC _ _ _ CHS Access 3® AP Fixed_ Core_ 1 _ AP rAccess 3® AS Fixed Core - - AS - j Access 3® AHS Fixed Core AHS Access 3e AP IC -- T ` _ 4 - ACP_ Access 3® AS IC -1ACS - - - - - --1 _ A- CHS - Cylinders only (not for HS, CHS, PHS, PCHS or Access 3e) Loncealed key control (CKC) _ CKC cylinders with V_KC keys __- CKC2 r—CKC cylinders only (not for PHS, PCHS, Access 3e) CKC3 2 keys per lock _ _ _ _ _(standard) „ More than 2 keys - _ KY# (e.g., KY6) Schlage®C keyway cylinder __ __ _ _ 1 _ C Sargent® LA keyway cylinder _CTP PS-- - _PCS f CTPD - _ CT6D _CT7D (standard) ( _KR CMK _- VKCO L VKC1 VKC2 VKC3 ANSI/BHMA 605 (US3) Bright Brass _ L ANSI/BHMA 606 (US4) Satin Brass _ ANSI/BHMA 611 (US9)- `Bright Bronze ANSI/BHMA 612 (US10) Satin Bronze Dark Oxidized Satin Bronze, Oil Rubbed Dark Oxidized Satin Bronze, _ _ _ _ .Equivalent, Dark Oxidized Satin Bronze, Clear 613E Coated _ ANSBBHMA 618 (US14) Bright Nickel Plated 618 CL3800 Finishes ANSI/BHMA 613 (US10B) 613E 613L [ -1/4" (57mm) 605 606 611 612 613 613E ANSI/BHMA 619 (US15) Satin Nickel Plated 619 r619C-- Satin Nickel Plated 619C 1 Microshield® ANSI/BHMA 625 (US26) Bright Chromium Plated 625 ANSI/BHMA 626 (US26D) Satin Chromium Plated 626 1 Satin Chromium Plated •41v 626C I with MicroShield®• 626C ANSI/BHMA 722 Black Oxidized Bronze, oil rubbed 722 1 Strikes GriID Curved f (, r I toC�enter Curved (11.3 Specify j Radius Corner SpecifySpecify Specify 1 "(25mm)_ SA100 1 SC100 I N/A N/A 1-1/8" (29mm)� SA118 SC118 N/A N/A 1-1/4° (32mm) i (standard) L SC114 _ - SF114 i SFR114 1-3/8" (35mm) SA138 SC138_ N/A N/A 1-1/2" (38mm) SA112 I SC112 I �N/A N/A � 1-3/4" (44mm) SA134 SC134 N/A N/A 2" (51mm) 1 SA200 2-1/2" (64mm) t 2-3/4" (70mm) 3" (76mm) SC200 N/A N/A SA214_SC21_4 N/A N/A SA212 j_ SC212 Ii_N/A J N/A _ SA234 SC234 N/A N/A _ 1 SA300 L SC300 1 N/A f N/A Rabbeted front and strike Door Thickness Specify SR118 1-3/8" (35mm) - 1-3/4" (44mm) F 2" (51mm) - 2-1/4" (57mm) Backset Specify (standard) __-D214 Description Specify LA _ _ 2-3/8" (60mm) 2-3/4" (70mm) 3-3/4° (95mm) 8238 (standard) B334 5" (127mm) — --8500 _ -- • ASSA ABLOY, the global leader in door opening solutions 45355-3/14 CL3800.11 Rus°swin fi ASSA ABLOY Quick Codes CL3800 Miscellaneous Options Description Spanner head screws Less cylinder, with tailpiece for Schlage® cylinder Lever to accept SFIC 6 or 7-pin interchangeable core (NZD & PZD design only) Lever to accept Sargent® cylinder (N2D & PZD designs only) Lever to accept Schlage® Interchangeable core (NZD & PZD design only) Specify M02 M06 M08 M09 M69 Rounded corners on latch front M13 1" latch front, square corners (standard for 2-3/8" M14 backset) 1 " latch front, rounded corners M15 ANSI wrought strike box M17 Knurling outside and inside M20 Knurling outside only M21 Knurling inside only M22 Abrasive coat outside and inside M23 Abrasive coat inside only M24 Abrasive coat outside only M25 . 1-1/8° front, square corners (standard for 2-3/4', 3-3/4"and 5" backsets) M32 CL3800.12 ASSA ABLOY, the global leader in door opening solutions 45355-3/14 Suggested Specification Lockset chassis shall be constructed of heavy gauge steel and cast components, plated to protect against rust and corrosion. Locksets shall be adjustable for 1-3/8" (35mm) and 1-3/4" (44mm) or 2" (51 mm) and 2-1/4" (57mm) door thickness. Locksets shall be non -handed, and shall install easily without the need for specialized installation tools. Locksets shall have separate anti -rotation through -bolts in the 6 o'clock and 12 o'clock position outside the 2-1/8" face bore, and shall have no exposed mounting screws. Locksets shall have solid one-piece, cast levers without plastic inserts, and shall be a minimum of 4" (102mm) in length. Levers shall operate independently, and shall have inside and outside lever return springs. Outside levers on the keyed locksets shall be removable only when the designated key is in the cylinder. Vandal -resistant levers shall be offered as a standard feature in all locking functions and shall be free -wheeling in the locked condition. Locksets that are rigid in the locked condition, or must require resetting (breakaway) are not acceptable. All locksets shall carry a seven-year mechanical warranty. All locksets shall comply with the following certifications: • UL-cUL 3-Hour Fire Rating • ANSI/BHMA A156.2 Series 4000, Grade 2 • ANSI/BHMA A117.1 Accessibility Code • ANSI/BHMA A115.1 B Preparation All locksets shall be CL3800 Series Grade 2 Key -in -Lever Cylindrical Locksets as manufactured by Corbin Russwin Architectural Hardware. ASSA ABLOY, the global leader in door opening solutions C L3800.13 45355-3/14 Structural Calculations: Gravity & Lateral Load Design for Remodel of Existing Leasing Office Owner: Courtyard Apartments c/o Courtyard at South Station 3900 Southcenter Blvd. Tukwila, Washington 98168 Designers: Bernhoft & Associates 702 Broadway, Suite 201 Tacoma, Washington 98402 253-274-0244 Engineer: Bruce S. MacVeigh, P.E. 14245 59th Avenue South Tukwila, Washington 98168 206.571.8794 Job # 2014-R4-Roberts bli+0.2.87 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 4 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP. 0 2 2014 PERMIT CENTER IEXPIRES 4/24/2015 I 0s- 7-ve //4 All information for construction is detailed on the prints. This engineering report summarizes the engineering calculations and assumptions made to develop the print information. Contractor must review engineering assumptions for validity. Engineering assumptions are listed below. If these conditions are not present at the site these calculations are void. Bernhoft & Associates and Bruce S. MacVeigh, P.E. must be contacted immediately at 253-274-0244. INTRODUCTION: This engineering report summarizes the results of the lateral and gravity load engineering services for the proposed structure. SCOPE OF WORK: The Scope of Work is to provide engineering analysis and design to resist lateral and gravity loads in accordance with the 2012 IBC . Our services extend from the foundation up to the roof. Foundations are engineered to support the structure on a flat surface with a minimum 1500 psf soil bearing. Special foundations for lots not level or with poor soil bearing are not provided unless noted otherwise. The enclosed documents are to be used in conjunction with the house plans referenced on the cover. It is essential that the contractor study the engineering requirements and required changes to the architectural plan prior to start of work. Changes may include additional foundations or footings, beam size changes, siding changes etc. r c CODE CRITERIA: Building Codes Seismic Zone Period T (sec) Response Mod Factor Soil Profile Seismic Source Type Spectral Response Acceleration Reliability Factor Rho Wind Zone Kzt Factor SOILS CRITERIA Soils Consultant Soils Report # Bearing Pressure Req'd Bearing Depth MATERIALS CRITERIA Concrete (28 day strength) Foundations and Slab Structural Slab Walls Reinforcing Steel Glu-Lam Beams PLYWOOD APA RATED 2012 IBC Code D1 0.167 6.5 D D Si: 0.544 g, Ss: 1.459 g 1.0 85 mph, 3 second gust, Exposure D 1.00 None None 1500 psf uno 12" Frost Level Fc= 2500psi Fc= 2500psi Fc= 2500psi ASTM A-615 Grade 40 - #4 & #5 Bars ASTM A-615 Grade 60 - #6 Bars and larger Visually Graded Western Species- Dry Use Fb = 2400 psi, V4 Roof: 1/2" cdx or 7/16" osb PI = 24/0 Floor: 3/4" T&G cdx or osb PI = 48/24 LOADING CRITERIA FOR ROOF AND/OR CEILING ITEM MATERIAL LOAD PSF Roofing Asphalt Shingles 3.0 Sheathing or Decking 7/16 CDX 1.5 Insulation R49 2.0 Framing Truss @ 24" o.c. 2.1 Ceiling 5/8 GWB 2.8 Miscellaneous 2.0 Total dead load 13.4 psf LIVE LOADS: Snow — 25 PSF (Non reducible) Ceiling Only —10 PSF Increase in Fb and Fir of 15% allowed for duration of load when noted. LOADING CRITERIA FOR FLOOR: TOTAL DEAD LOAD FLOOR = 4" Concrete Floor Slab FLOOR LIVE LOADS: Office — 50 PSF WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 10.1 2014-R4-roberts.wsw Project Information COMPANY AND PROJECT INFORMATION Company Project Bruce S MacVeigh, P.E. 14245 59th Avenue South Tukwila, Washington 98168 (206) 571-8794 Riverton Ridge Leasing Office 3900 Southcenter Blvd Tukwila, Washington 98168 DESIGN SETTINGS Jul. 8, 2014 10:26:55 Design Code Wind Standard Seismic Standard IBC 2012/AWC SDPWS 2008 ASCE 7-10 Directional (All heights) ASCE 7-10 Load Combinations For Design (ASD) For Deflection (Strength) 0.70 Seismic + 0.60 Dead 1.00 Seismic + 0.90 Dead 0.60 Wind + 0.60 Dead 1.00 Wind + 0.90 Dead Building Code Capacity Reduction Wind Seismic 1.00 1.00 Service Conditions and Load Duration Duration Temperature Moisture Content Factor Range Fabrication Service 1.60 T<=100F 19% 10% Max Shearwall Offset [ft] Plan Elevation (within story) (between stories) 0.50 - Maximum Height -to -width Ratio Wood panels Fiberboard Lumber Gypsum Wind Seismic Wind Seismic Blocked Unblocked 3.5 3.5 - - - - - Ignore non -wood -panel shear resistance contribution... Wind Seismic Never Never Collector forces based on... Hold-downs Applied loads Drag struts Applied loads Shearwall Relative Rigidity: Deflection -based stiffness of wall segments Design Shearwall Force/Length: Based on wall rigidity/length SITE INFORMATION Wind ASCE 7-10 Directional (All heights) Seismic ASCE 7-10 12.8 Equivalent Lateral Force Procedure Design Wind Speed 85mph Exposure Exposure B Enclosure Enclosed Min Wind Loads: Walls 16 psf Roofs 8 psf Risk Category Structure Type Building System Design Category Site Class Category II - All others Regular Bearing Wall D D Topographic Information [ft] Shape Height Length - - - Site Location: - Spectral Response Acceleration S1:0.544g Ss:1.459g Fundamental Period T Used Approximate Ta Maximum T E-W 0.095s 0.095s 0.133s N-S 0.095s 0.095s 0.133s Elev: Oft Avg Air density: 0.0765 lb/cu ft Rigid building - Static analysis Case 2 E-W loads N-S loads Eccentricity (%) 15 15 Loaded at 75% Response Factor R 6.50 6.50 Fa: 1.00 Fv: 1.50 1 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 Structural Data STORY INFORMAT ON Ceiling Level 1 Foundation Hold-down Story Floor/Ceiling Wall Length subject to Bolt Elev [ft] Depth [in] Height [ft] shrinkage [in] length [in] 8.00 0.00 0.00 0.0 0.0 8.00 3.8 4.5 BLOCK and ROOF INFORMATION Block Dimensions [ft] Face Type Roof Panels Slope Overhang [ft] Block 1 1 Story N-S Ridge Location X,Y = 0. 00 0. 00 North Gable 90.0 1.00 Extent X,Y = 20.00 32.00 South Gable 90.0 1.00 Ridge X Location, Offset 10.00 0.00 East Side 23.0 1.00 Ridge Elevation, Height 12.24 4.24 West Side 23.0 1.00 2 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 SHEATHING MATERIALS by WALL GROUP Grp Surf Material Ratng Sheathing Thick in GU in Ply Or Gvtv Ibs/in Size Fasteners Type Df Eg in Fd in Bk Apply Notes 1 Ext Struct Sh OSB 24/16 7/16 - 3 Horz 83500 8d Nail N 6 12 Y 3 Legend: Grp — Wall Design Group number, used to reference wall in other tables Surf — Exterior or interior surface when applied to exterior wall Ratng — Span rating, see SDPWS Table C4.2.2.2C Thick— Nominal panel thickness GU - Gypsum underlay thickness Ply — Number of plies (or layers) in construction of plywood sheets Or — Orientation of longer dimension of sheathing panels Gvtv— Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.2A-B Type — Fastener type from SDPWS Tables 4.3A-D: Nail — common wire nail for structural panels and lumber, cooler or gypsum wallboard nail for GWB, plasterboard nail for gypsum lath, galvanised nail for gypsum sheathing; Box - box nail; Casing — casing nail; Roof— roofing nail; Screw — drywall screw Size - Common, box, and casing nails: refer to SDPWS Table Al (casing sizes = box sizes). Gauges: 11 ga = 0.120" x 1-3/4" (gypsum sheathing, 25/32" fiberboard ), 1-1/2" (lath & plaster, 1/2" fiberboard); 13 ga plasterboard = 0.92" x 1- 1/8". Cooler or gypsum wallboard nail: 5d = .086"x 1-5/8"; 6d = .092"x 1-7/8"; 8d = .113" x 2-3/8"; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. Drywall screws: No. 6, 1-1/4"long. 5/8" gypsum sheathing can also use 6d cooler or GWB nail Df — Deformed nails ( threaded or spiral), with increased withdrawal capacity Eg — Panel edge fastener spacing Fd — Field spacing interior to panels Bk — Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) Apply Notes — Notes below table legend which apply to sheathing side Notes: 3. Shear capacity for current design has been increased to the value for 15/32" sheathing with same nailing because stud spacing is 16" max. or panel orientation is horizontal. See SDPWS T4.3A Note 2. FRAMING MATERIALS by WALL GROUP Wall Group Species Grade b in d in Spacing in SG E psiA6 1 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 �egena: Wall Group — Wall Design Group b — Stud breadth (thickness) d — Stud depth (width) Spacing — Maximum on -centre spacing of studs for design, actual spacing may be less. SG — Specific gravity E — Modulus of elasticity Notes: Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. 3 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 WoodWorks® Shearwalls DIMENSIONS North -south Shearlines Type Wall Group(s) Location x[ft] Extent [ft] Start End Length [ft] FHS [ft] Wind Seismic Height [ftj Line 1 Level 1 Line 1 Seg 1 0.00 0.00 32.00 32.00 19.25 19.25 8.00 wall 1-1 Seg 1 0.00 0.00 32.00 32.00 19.25 19.25 - Opening 1 - - 10.00 13.00 3.00 - - 6.75 Opening 2 - - 19.67 22.67 3.00 - - 6.75 Opening 3 - - 25.25 28.25 3.00 - - 6.75 Opening 4 - - 29.00 31.00 2.00 - - 5.00 Line 2 Level 1 Line 2 Seg 1 20.00 0.00 32.00 32.00 21.33 21.33 8.00 Wall 2-1 Seg 1 20.00 0.00 32.00 32.00 21.33 21.33 - Opening 1 - - 12.50 15.50 3.00 - - 6.75 Opening 2 - - 17.17 19.17 2.00 - - 5.00 Opening 3 - - 20.17 23.17 3.00 - - 6.75 East -west Type Wall Location Extent [ft] Length FHS [ft] Height Shearlines Group(s) Y [ft] Start End [ft] Wind Seismic [ft] Line A Level 1 Line A Seg 1 0.00 0.00 20.00 20.00 17.00 17.00 8.00 Wall A-1 Seg 1 0.00 0.00 20.00 20.00 17.00 17.00 - Opening 1 - - 8.50 11.50 3.00 - - 6.75 Line B Level 1 Line B Seg 1 16.00 0.00 20.00 20.00 18.33 18.33 8.00 Wall B-1 Seg 1 16.00 0.00 20.00 20.00 18.33 18.33 - Opening 1 - - 10.42 12.08 1.67 - - 6.75 Line C Level 1 Line C Seg 1 32.00 0.00 20.00 20.00 14.00 14.00 8.00 Wall C-1 Seg 1 32.00 0.00 20.00 20.00 14.00 14.00 - Opening 1 - - 10.00 16.00 6.00 - - 3.00 �egena: Type - Seg = segmented, prf = perforated, NSW = non-shearwall;; Location - dimension perp. to wall; FHS - length of full -height sheathing used to resist shear force; Wall Group(s) - refer to Materials by Wall Group table, refer to Shear Results tables for each design case if more than one group 4 a r 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 WoodWorks® Shearwalls Loads R LOADS (as entered or generated Level 1 Block F Element Load Case Wnd Dir Surf Dir Prof Location [ft] Start End Magnitude [Ibs,pif,psf] Start Trib Ht End [ft] Block 1 W Roof Min W->E Wind Line -1.00 33.00 18.7 Block 1 W Roof 1 W->E Wind Line -1.00 33.00 4.2 Block 1 W Wall Min W->E Wind Line 0.00 32.00 32.0 Block 1 W Wall 1 W->E Wind Line 0.00 32.00 24.6 Block 1 E Roof Min W->E Lee Line -1.00 33.00 18.7 Block 1 E Roof 1 W->E Lee Line -1.00 33.00 21.5 Block 1 E Wall 1 W->E Lee Line 0.00 32.00 15.4 Block 1 E Wall Min W->E Lee Line 0.00 32.00 32.0 Block 1 W Roof 1 E->W Lee Line -1.00 33.00 21.5 Block 1 W Roof Min E->W Lee Line -1.00 33.00 18.7 Block 1 W Wall 1 E->W Lee Line 0.00 32.00 15.4 Block 1 W Wall Min E->W Lee Line 0.00 32.00 32.0 Block 1 E Roof 1 E->W Wind Line -1.00 33.00 4.2 Block 1 E Roof Min E->W Wind Line -1.00 33.00 18.7 Block 1 E Wall Min E->W Wind Line 0.00 32.00 32.0 Block 1 E Wall 1 E->W Wind Line 0.00 32.00 24.6 Block 1 S Wall Min S->N Wind Line 0.00 20.00 32.0 Block 1 S L Gable Min S->N Wind Line 0.00 10.00 0.0 34.0 Block 1 S Wall 1 S->N Wind Line 0.00 20.00 24.6 Block 1 S L Gable 1 S->N Wind Line 0.00 10.00 0.0 26.1 Block 1 S R Gable 1 S->N Wind Line 10.00 20.00 26.1 0.0 Block 1 S R Gable Min S->N Wind Line 10.00 20.00 34.0 0.0 Block 1 N L Gable 1 S->N Lee Line 0.00 10.00 0.0 12.4 Block 1 N Wall 1 S->N Lee Line 0.00 20.00 11.7 Block 1 N L Gable Min S->N Lee Line 0.00 10.00 0.0 34.0 Block 1 N Wall Min S->N Lee Line 0.00 20.00 32.0 Block 1 N R Gable Min S->N Lee Line 10.00 20.00 34.0 0.0 Block 1 N R Gable 1 S->N Lee Line 10.00 20.00 12.4 0.0 Block 1 S Wall Min N->S Lee Line 0.00 20.00 32.0 Block 1 S L Gable Min N->S Lee Line 0.00 10.00 0.0 34.0 Block 1 S L Gable 1 N->S Lee Line 0.00 10.00 0.0 12.4 Block 1 S Wall 1 N->S Lee Line 0.00 20.00 11.7 Block 1 S R Gable Min N->S Lee Line 10.00 20.00 34.0 0.0 Block 1 S R Gable 1 N->S Lee Line 10.00 20.00 12.4 0.0 Block 1 N L Gable Min N->S Wind Line 0.00 10.00 0.0 34.0 Block 1 N L Gable 1 N->S Wind Line 0.00 10.00 0.0 26.1 Block 1 N Wall Min N->S Wind Line 0.00 20.00 32.0 Block 1 N Wall 1 N->S Wind Line 0.00 20.00 24.6 Block 1 N R Gable Min N->S Wind Line 10.00 20.00 34.0 0.0 Block 1 N R Gable 1 N->S Wind Line 10.00 20.00 26.1 0.0 Legend: Block - Block used in load generation Accum. = loads from one block combined with another Manual = user -entered loads (so no block) F - Building face (north, south, east or west) Element - Building surface on which loads generated or entered Load Case - One of the following: ASCE 7 All Heights: Case 1 or 2 from Fig 27.4-8 or minimum loads from 27.1.5 ASCE 7 Low-rise: Reference comer and Case A or B from Fig 28.4-1 or minimum loads from 28.4.4 Wind Dir - Direction of wind for loads with positive magnitude, also direction of MWFRS. Sur` Dir - Windward or leeward side of the building for loads in given direction Prof - Profile (distribution) Location - Start and end points on building element Magnitude - Start = intensity of uniform and point loads or leftmost intensity of trapezoidal load, End = right intensity of trap load Trib Ht - Tributary height of area loads only Notes: AU Toads entered by the user or generated by program are specified (unfactored) loads_The program applies a load factor of 0.60 to wind loads before distributing them to the shearlines. 5 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 WIND C&C LOADS Block Building Face Wind Direction Level Magnitude [psf] Interior End Zone Block 1 West Windward 1 16.0 17.4 Block 1 East Leeward 1 16.0 17.4 Block 1 West Leeward 1 16.0 17.4 Block 1 East Windward 1 16.0 17.4 Block 1 South Windward 1 16.0 17.4 Block 1 North Leeward 1 16.0 17.4 Block 1 South Leeward 1 16.0 17.4 Block 1 North Windward 1 16.0 17.4 DEAD LOADS (for hold-down calculations) Shear Level Profile Tributary Location [ft] Line Width [ft] Start End Start End Mag [Ibs,psf,psi] A 1 Area 2.00 0.00 20.00 13.0 B 1 Area 2.00 0.00 20.00 13.0 C 1 Area 2.00 0.00 20.00 13.0 1 1 Area 12.00 0.00 32.00 13.0 2 1 Area 12.00 0.00 32.00 13.0 6 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 BUILDING MASSES Level 1 Force Building Dir Element E-W Roof E-W Roof Block Wall Line Block 1 1 Block 1 2 N-S Roof Block 1 A N-S Roof Block 1 C N-S L Gable Block 1 A N-S R Gable Block 1 A N-S R Gable Block 1 C N-S L Gable Block 1 C Both Wall 1-1 n/a 1 Both Wall 2-1 n/a 2 Both Wall A-1 n/a A Both Wall B-1 n/a B Both Wall C-1 n/a C Profile Location [ft] Magnitude Trib pbs,Plf,Psf] Width Start • End Start End [ft] Line -1.00 33.00 143.0 143.0 Line -1.00 33.00 143.0 143.0 Line -1.00 21.00 221.0 221.0 Line -1.00 21.00 221.0 221.0 Line 0.00 10.00 42.4 0.0 Line 10.00 20.00 0.0 42.4 Line 0.00 10.00 42.4 0.0 Line 10.00 20.00 0.0 42.4 Line 0.00 32.00 40.0 40.0 Line 0.00 32.00 40.0 40.0 Line 0.00 20.00 40.0 40.0 Line 0.00 20.00 24.0 24.0 Line 0.00 20.00 40.0 40.0 Legend: Force Dir - Direction in which the mass is used for seismic load generation, E-W, N-S, or Both Building element - Root gable end, wall or floor area used to generate mass, wall line for user -applied masses, Floor F# - refer to Plan View for floor area number Wall line - Sheariine that equivalent line load is assigned to Location - Start and end points of equivalent line load on wall line Trib Width. - Tributary width; for user applied area loads only 7 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 SEISMIC LOADS Level 1 Force Profile Location [ft] Mag [Ibs,plf,pst] Dir Start End Start End E-W Line -1.00 0.00 42.8 42.8 E-W Point 0.00 0.00 183 183 E-W Line 0.00 32.00 54.8 54.8 E-W Point 16.00 16.00 72 72 E-W Point 32.00 32.00 183 183 E-W Line 32.00 33.00 42.8 42.8 N-S Line -1.00 0.00 66.1 66.1 N-S Point 0.00 0.00 192 192 N-S Line 0.00 10.00 81.7 94.4 N-S Line 10.00 20.00 94.4 81.7 N-S Point 20.00 20.00 192 192 N-S Line 20.00 21.00 66.1 66.1 Legend: Loads in table can be accumulation of loads from several building masses, so they do not correspond with a particular building element. Location - Start and end of load in direction perpendicular to seismic force direction Notes: All loads entered by the user or generated by program are specified (unfactored) loads.The program applies a load factor of 0.70 and redundancy factor to seismic loads before distributing them to the shearlines. 8 WoodWorks® Shearwails 2014-R4-roberts.wsw Jul. 8, 201410:26:55 Flexible Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads --- North-South Shearlines W Gp For Dir HIW-Cub Int Ext ASD Shear Force [pH] V [Ms] vmax v Int Allowable Shear [pit] Ext Co C Total V [lbs] Crit. Resp. Line 1 Level 1 Lnl, Levi 1 S->N 1.0 588 52.0 52.0 364 1.00 S 364 7007 0.14 1 N->S 1.0 588 58.6 58.6 364 1.00 S 364 7007 0.16 Line 2 Ln2, Levl 1 Both 1.0 588 46.6 46.6 364 1.00 S 364 7765 0.13 East-West W For H/W-Cub ASD Shear Force [pit] Allowable Shear [pit] Crit. Shearlines Gp Dir Int Ext V [Ibsj vmax v Int Ext Co C Total V [Ibs] Resp. Line A Level 1 LnA, Levl 1 Both 1.0 509 29.9 29.9 364 1.00 S 364 6188 0.08 Line B LnB, Levl 1 W->E 1.0 973 84.4 84.4 364 1.00 S 364 6673 0.23 1 E->W 1.0 973 88.4 88.4 364 1.00 S 364 6673 0.24 Line C LnC, Levl 1 W->E 1.0 509 48.7 48.7 364 1.00 S 364 5096 0.13 1 E->W 1.0 509 50.0 50.0 364 1.00 S 364 5096 0.14 Legend: Unless otherwise noted, the value in the table for a shearline is the one for wall on the line with the critical design response. W Gp - Wall group as listed in Sheathing and Framing Materials tables. For Dir - Direction of wind force along shearline. H/W-Cub - Fibreboard height -to -width factor from SDPWS table 4.3.4 note 3, or Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. V - ASD factored shear force. For shearline: total shearline force. For wall: force taken by the wall, total of all segments on wall. vmax - Base shear = ASD factored shear force per unit full height sheathing, divided by perforation factor Co as per SDPWS eqn. 4.3-8 = V/FHS/Co. v - Design shear force = ASD factored shear force per unit full height sheathing. For wall, it is the largest force on any segment. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. Includes Cub and height -to -width factors. Co - Perforation factor from SDPWS Table 4.3.3.5. C - Sheathing combination rule, A = Add capacities, S = Strongest side only, X = Strongest side or twice weakest. Total - Combined unit shear capacity inc. perforation factor. V - For wall: combined shear capacity. For shearline: sum of all wall capacities on line. Crit Resp - Critical response = v/Total = design shear force/unit shear capacity for critical segment on wall or shearline. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 9 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 HOLD-DOWN DESIGN ( flexible wind design Level 1 Line- Wall Positn Location [ft] X Y Load Case Tensile ASD Holddown Force [ibs] Shear Dead Uplift Cmb'd Hold-down Cap [Ibs] Crit Resp. Line 1 1-1 L End 0.00 0.12 Min 416 468 1-1 L Op 1 0.00 9.87 Min 469 613 5 1-1 R Op 1 0.00 13.13 Min 87. 457 5 1-1 L Op 2 0.00 19.54 Min 1 457 5 1-1 R Op 2 0.00 22.79 Min 1 266 5 1-1 L Op 3 0.00 25.13 Min 1 266 5 1-1 R Op 4 0.00 28.38 1 181 1-1 L Op 4 0.00 28.88 1 132 1-1 R Op 4 0.00 31.13 1 144 1-1 R End 0.00 31.88 1 47 Line 2 2-1 L End 20.00 0.12 Min 373 585 2-1 L Op 1 20.00 12.38 Min 373 730 5 2-1 R Op 3 20.00 15.63 1 223 2-1 L Op 3 20.00 17.04 1 175 2-1 R Op 3 20.00 19.29 1 144 2-1 L Op 3 20.00 20.04 1 192 2-1 R Op 3 20.00 23.29 Min 5 559 5 2-1 R End 20.00 31.88 Min 5 413 LineA A-1 L End 0.12 0.00 Min 293 66 227 STHD10 2940 0.08 A-1 L Op 1 8.38 0.00 Min 293 95 5 204 STHD10 2940 0.07 A-1 R Op 1 11.63 0.00 Min 293 95 5 204 STHD10 2940 0.07 A-1 R End 19.88 0.00 Min 293 66 227 STHD10 2940 0.08 Line B B-1 L End 0.12 16.00 Min 676 81 594 LSTHD8 1950 0.30 B-1 L Op 1 10.29 16.00 Min 707 94 613 LSTHD8 1950 0.31 B-1 R Op 1 12.21 16.00 Min 94 75 20 LSTHD8 1950 0.01 B-1 R End 19.88 16.00 Min 52 62 Line C C-1 L End 0.12 32.00 Min 493 78 415 STHD10 2940 0.14 C-1 L Op 1 9.87 32.00 Min 506 135 10 381 STHD10 2940 0.13 C-1 R Op 1 16.13 32.00 Min 47 88 10 C-1 R End 19.88 32.00 Min 20 31 �egena: Line -Wall: At wall or opening - Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All Heights: Case 1 or 2 from Fig. 27.4-8 ASCE 7 Low-rise: Windward comer(s) and Case A or 8 from Fig. 28.4-1 ASCE 7 Minimum loads (27.1.5/28.4.4) Hold-down Forces: Shear - Wind shear overturning component; based on shearline force, includes perforation factor Co, factored forASD by 0.60 Dead - Dead load resisting component, factored forASD by 0.60 Uplift - Uplift wind load component, factored forASD by 0.60 Cmb'd - Sum of ASD factored overtuming, dead and uplift forces. May also include the uplift force t for perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down - Device used from hold-down database Cap - Allowable ASD tension load Crit Resp. - Critical Response = Combined ASD force /Allowable ASD tension load Notes: Refer to Shear Results table for perforation factors Co. 10 WoodWorks® Shearwalls DRAG STRUT FORCES ( flexible wind design) Level 1 Line - Wall Position on Wall or Opening Location (ft] Load X Y Case Line 1 1-1 Left Opening 1 0.00 10.00 1 1-1 Right Opening 1 0.00 13.00 1 1-1 Left Opening 2 0.00 19.67 1 1-1 Right Opening 2 0.00 22.67 1 1-1 Left Opening 3 0.00 25.25 1 Line 2 2-1 Left Opening 1 20.00 12.50 1 2-1 Right Opening 3 20.00 23.17 1 Line A A-1 Left Opening 1 8.50 0.00 1 A-1 Right Opening 1 11.50 0.00 1 Line B B-1 Left Opening 1 10.42 16.00 1 B-1 Right Opening 1 12.08 16.00 1 Line C C-1 Left Opening 1 10.00 32.00 1 C-1 Right Opening 1 16.00 32.00 1 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 Drag Strut Force (Ibs] —> <- 336 403 281 348 231 226 176 171 129 124 353 353 157 157 38 38 38 38 373 414 292 333 233 245 80 93 Legend: Line -Wall - Shearline and wall number Position.. - Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All heights Case 1 or 2 ASCE 7 Low-rise comer; Case A or B Drag strut Force - Axial force in transfer elements at openings and gaps in walls along shearline. Based on ASD factored shearline force, includes perforation factor Co. -> Due to shearline force in the west -to -east or south -to -north direction <- Due to shearline force in the east -to -west or north -to -south direction 11 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 flexible wind design Wall, segment W Gp Dir Srf v plf b ft h ft Bending A Defl sq.in in Shear Defl in Vn Ibs Nail slip en in Defl in Hold Defl in Total Defl in Level 1 Line 1 1 1-1,1 S->N Ext 85.1 10.00 8.00 16.5 .002 .008 43 .000 .002 0.03 0.04 N->S Ext 97.7 10.00 8.00 16.5 .002 .009 49 .001 .003 0.03 0.05 1-1,2 S->N Ext 20.4 6.67 8.00 16.5 .001 .002 10 .000 .000 0.05 0.05 N->S Ext 0.3 6.67 8.00 16.5 .000 .000 0 .000 .000 0.05 0.05 1-1,3 Both Ext 0.0 2.58 8.00 16.5 .000 .000 0 .000 .000 0.00 0.00 Line 2 1 2-1,1 Both Ext 77.6 12.50 8.00 16.5 .001 .007 39 .000 .002 0.03 0.04 2-1,4 Both Ext 1.1 8.83 8.00 16.5 .000 .000 1 .000 .000 0.04 0.04 Line A 1 A-1,1 Both Ext 49.9 8.50 8.00 16.5 .001 .005 25 .000 .000 0.21 0.22 A-1,2 Both Ext 49.9 8.50 8.00 16.5 .001 .005 25 .000 .000 0.21 0.22 Line B 1 B-1,1 W->E 1 138.9 10.42 8.00 16.5 .002 .013 69 .002 .010 0.15 0.18 E->W 1 146.5 10.42 8.00 16.5 .002 .014 73 .002 .012 0.15 0.18 B-1,2 W->E 1 22.1 7.92 8.00 16.5 .000 .002 11 .000 .000 0.20 0.20 E->W 1 12.1 7.92 8.00 16.5 .000 .001 6 .000 .000 0.20 0.20 Line C 1 C-1,1 W->E Ext 76.8 10.00 8.00 16.5 .001 .007 38 .000 .002 0.18 0.19 E->W Ext 81.3 10.00 8.00 16.5 .001 .008 41 .000 .002 0.18 0.19 C-1,2 W->E Ext 20.1 4.00 8.00 16.5 .001 .002 10 .000 .000 0.45 0.45 E->W Ext 8.7 4.00 8.00 16.5 .000 .001 4 .000 .000 0.45 0.45 Legend: Wall, segment - Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Sheariine B W Gp - Wall design group, refer to Sheathing and Framing Materials Dir- Force direction Srf - Wall surface, interior or exterior for perimeter walls, 1 or 2 for interior partitions v- Unfactored (strength -level) shear force per unit foot on wall segment = ASD force / 0.60 b - Width of wall segment between openings h - Wall height Defl - Horizontal shearwall deflection due to given term: Bending = 8vh^3 / EAb; A - Cross sectional area of segment end stud(s); E - stud mod. of elasticity in Framing Materials table Shear = vh / Gt ; Gt - Shear stiffness from SDPWS C4.3.3.2, value is in Sheathing Materials table Nail slip = 0.75 h x en; en - From SDPWS Table C4.2.2D; Vn - Unfactored shear force per nail along panel edge Hold - Hold-down = da x h / b; refer to Hold-down Displacement table for components of da Total defl = Deflection from bending + shear + nail slip + hold-down, as per SDPWS C4.3.2-1 12 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 HOLD-DOWN DISPLACEMENT ( flexible wind design Wall, segment Dir Hold- down Uplift force Ibs Elong / Disp Manuf Add in in da in Slippage Pf da Ibs in Shrink da in Crush+ Extra in Total da in Hold Defl in Level 1 Line 1 1-1,1 S->N STHD10 -9 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 N->S STHD10 -130 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 1-1,2 S->N STHD10 -533 .000* .000 0.000 - - 0.000 0.04 0.04 0.05 N->S STHD10 -676 .000* .000 0.000 - - 0.000 0.04 0.04 0.05 1-1,3 Both STHD10 -390 .000* .000 0.000 - - 0.000 0.00 0.00 0.00 Line 2 2-1,1 S->N STHD10 -256 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 N->S STHD10 -466 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 2-1,4 S->N STHD10 -821 .000* .000 0.000 - - 0.000 0.04 0.04 0.04 N->S STHD10 -612 .000* .000 0.000 - - 0.000 0.04 0.04 0.04 Line A A-1,1 W->E STHD10 390 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 E->W STHD10 355 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 A-1,2 W->E STHD10 355 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 E->W STHD10 390 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 Line B B-1,1 W->E LSTHD8 1004 .089* .000 0.089 - - 0.068 0.04 0.20 0.15 E->W LSTHD8 1038 .089* .000 0.089 - - 0.068 0.04 0.20 0.15 B-1,2 W->E LSTHD8 45 .089* .000 0.089 - - 0.068 0.04 0.20 0.20 E->W LSTHD8 -5 .089* .000 0.089 - - 0.068 0.04 0.20 0.20 Line C C-1,1 W->E STHD10 705 .117* .000 0.117 - - 0.068 0.04 0.22 0.18 E->W STHD10 658 .117* .000 0.117 - - 0.068 0.04 0.22 0.18 C-1,2 W->E STHD10 -36 .117* .000 0.117 - - 0.068 0.04 0.22 0.45 E->W STHD10 -13 .117* .000 0.117 - - 0.068 0.04 0.22 0.45 �egeno: Wall, segment- Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Shearline B Dir - Force direction Uplift force (P) -Strength-level accumulated hold-down tension force from overturning, dead and wind uplift da - Vertical displacements due to the following components: Elong/Disp - Elongation when slippage calculated separately; displacement when combined elongation/slippage used Manuf - Using manufacturer's value for anchor bolt length, or no bolt contribution for connector -only elongation. Unless marked with * = (ASD uplift force /ASD hold-down capacity) x max strength -level elongation or displacement * - Maximum strength -level elongation or displacement is used. May result in higher than actual displacements for lightly loaded hold-downs, causing the segment to draw less force due to lower than actual stiffness. Add - Due to longer anchor bolt length than manufacturer's value, or entire bolt length for connector -only elongation = PL / ( Ab x 'Es ); Ab - bolt cross -sectional area; Es = steel modulus = 29000000 psi; L = Lb - Lh; Lb = Total bolt length shown in Storey Information table; Lh = Manufacturer's anchor bolt length for given displacement/elongation from hold-down database. Slippage - Due to vertical slippage of hold-down fasteners attached to stud(s) when not combined with elongation Pf = Unfactored uplift force P / number of fasteners Bolts: = Pf/(270,000 D^1.5) (NDS 10.3.6) ; D = bolt diameter Nails: = en, fromSDPWS Table C4.2.2D using Pf for Vn and values for Wood Structural Panel Shrink - Wood shrinkage = 0.002 x (19% fabrication - 10% in-service moisture contents) x Ls Ls = Perp.-to-grain length between fasteners subject to shrinkage, shown in Storey Information table Crush + Extra - 0.04" wood crushing at compression end of wall segment plus extra displacement due to mis-cuts, gaps, etc. Total da = Elong/Disp + Slippage + Shrink + Crush + Extra Hold Defl - Horizontal deflection = h/b x da (4th term in the deflection equation SDPWS C4.3.2-1) h = wall height; b = segment length between openings; h,b values in Deflection table 13 a WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 Wind Suction Design Line North -South Shearlines Lev Grp Sheathing [pst] Force Cap Force/ Cap Force End Fastener Withdrawal [Ibs] Cap Force/Cap Int End Int Service Cond Factors Temp Moist 1 1 1 17.4 178.7 0.10 23.2 21.3 105.5 0.22 0.20 1.00 1.00 2 1 1 17.4 178.7 0.10 23.2 21.3 105.5 0.22 0.20 1.00 1.00 East-West Sheathing [psf] Fastener Withdrawal pbs] Service Cond Shearlines Force Cap Force/ Force Cap Force/Cap Factors Line Lev Grp Cap End Int End Int Temp Moist A 1 1 17.4 178.7 0.10 23.2 21.3 105.5 0.22 0.20 1.00 1.00 C 1 1 17.4 178.7 0.10 23.2 21.3 105.5 0.22 0.20 1.00 1.00 Legend: Grp - Wall Design Group ( results for all design groups for rigid, flexible design listed for each wall ) Sheathing: Force - C&C end zone exterior pressures using negative (suction) coefficient in ASCE 7 Figure 30.4-1 added to interior pressure using coefficients from Table 26.11-1 Cap - Out -of -plane capacity of exterior sheathing from SDPWS Table 3.21, factored for ASD and load duration, and assuming continuous over 2 spans Fastener Withdrawal: Force - Force tributary to each nail in end zone and interior zone Cap - Factored withdrawal capacity of individual nail according to NDS 11.2-3 14 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 Flexible Diaphragm Seismic Design Level Mass Area [Ibs] [sq.ft] Story Shear (Ibs] E-W N-S Diaphragm Force Fpx [Ibs] E-W N-S 1 All 15213 640.0 15213 - 2276 2276 2276 2276 2959 2959 - - Legend: Building mass — Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12. Storey shear— Total unfactored (strength -level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11. Diaphragm force Fpx - Unfactored force intended for diaphragm design from Eqn 12.10-1; used by Shea,walls only for drag strut forces, see 12.10.2.1 Exception 2. Redundancy Factor p (rho): E-W 1.00, N-S 1.00 Automatically calculated according to ASCE 712.3.4.2. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 0.97; Ev = 0.195 D unfactored; 0.136 D factored; total dead load factor. 0.6 - 0.136 = 0.464 tension, 1.0 + 0.136 = 1.136 compression. 15 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 North -South Shearlines W Gp For Dir H/W-Cub Int Ext ASD Shear Force [pif] V [Ibs] vmax v int Allowable Shear [plf] Ext Co C Total V [IbsJ Crit. Resp. Line 1 Level 1 Ln1, Levi 1 S->N .65 797 73.0 73.0 168 1.00 S 168 3232 0.43 1 N->S .65 797 64.0 64.0 168 1.00 S 168 3232 0.38 Line2 Ln2, Levl 1 Both 1.0 797 59.5 59.5 260 1.00 S 260 5547 0.23 East-West W For HMI -Cub ASD Shear Force [Of] Allowable Shear [pif] Crit. Shearlines Gp Dir Int Ext V pbs] vmax v Int Ext Co C Total V pbs] Resp. Line A Level 1 LnA, Levl 1 Both 1.0 465 27.3 27.3 260 1.00 S 260 4420 0.11 Line B LnB, Levl 1 W->E 1.0 664 56.7 56.7 260 1.00 S 260 4767 0.22 1 E->W 1.0 664 52.6 52.6 260 1.00 S 260 4767 0.20 Line C LnC, Levl 1 W->E 1.0 465 44.3 44.3 260 1.00 S 260 3640 0.17 1 E->W 1.0 465 45.5 45.5 260 1.00 S 260 3640 0.18 Legend: Unless otherwise noted, the value in the table for a shearline is the one for wall on the line with the critical design response. W Gp - Wall group as listed in Sheathing and Framing Materials tables. For Dir- Direction of seismic force along shearline. H/W-Cub - Height -to -width factor from SDPWS table 4.3.4 notes 1, 3 or unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. V - ASD factored shear force. For shearline: total shearline force. For wall: force taken by the wall, total of all segments on wall. vmax - Base shear = ASD factored shear force per unit full height sheathing, divided by perforation factor Co as per SDPWS eqn. 4.3-8 = V/FHS/Co. v - Design shear force = ASD factored shear force per unit full height sheathing. For wall, it is the largest force on any segment. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. Includes Cub and height -to -width factors. Co - Perforation factor from SDPWS Table 4.3.3.5. C - Sheathing combination rule, A = Add capacities, S = Strongest side only, X = Strongest side or twice weakest. Total - Combined unit shear capacity inc. perforation factor. V - For wall: combined shear capacity. For shearline: sum of all wall capacities on line. Crit Resp - Critical response = v/Total = design shear force/unit shear capacity for critical segment on wall or shearline. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 16 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 Level 1 Line- Wall Posirn Location [ft] X Y Shear Tensile ASD Holddown Force [Ibs] Dead Ev Cmb'd Hold-down Cap [Ibs] Crit Resp. Line 1 1-1 L End 0.00 0.12 584 468 106 222 STHD10 2940 0.08 1-1 L Op 1 0.00 9.87 512 613 139 38 STHD10 2940 0.01 1-1 R Op 1 0.00 13.13 90 457 1-1 L Op 2 0.00 19.54 199 457 1-1 R Op 2 0.00 22.79 1 266 1-1 L Op 3 0.00 25.13 1 266 1-1 R Op 4 0.00 28.38. 181 1-1 L Op 4 0.00 28.88 132 1-1 R Op 4 0.00 31.13 144 1-1 R End 0.00 31.88 47 Line 2 2-1 L End 20.00 0.12 476 585 133, 24 STHD10 2940 0.01 2-1 L Op 1 20.00 12.38 476 730 2-1 R Op 3 20.00 15.63 223 2-1 L Op 3 20.00 17.04 175 2-1 R Op 3 20.00 19.29 144 2-1 L Op 3 20.00 20.04 192 2-1 R Op 3 20.00 23.29 48 559 2-1 R End 20.00 31.88 48 413 Line A A-1 L End 0.12 0.00 268 66 15 217 STHD10 2940 0.07 A-1 L Op 1 8.38 0.00 268 95 22 195 STHD10 2940 0.07 A-1 R Op 1 11.63 0.00 268 95 22 195 STHD10 2940 0.07 A-1 R End 19.88 0.00 268 66 15 217 STHD10 2940 0.07 Line B B-1 L End 0.12 16.00 453 81 18 390 LSTHD8 1950 0.20 8-1 L Op 1 10.29 16.00 421 94 21 348 LSTHD8 1950 0.18 8-1 R Op 1 12.21 16.00 74 75 17 17 LSTHD8 1950 0.01 8-1 R End 19.88 16.00 117 62 14 69 LSTHD8 1950 0.04 Line C C-1 L End 0.12 32.00 449 78 18 389 STHD10 2940 0.13 C-1 L Op 1 9.87 32.00 461 135 31 357 STHD10 2940 0.12 C-1 R Op 1 16.13 32.00 48 88 C-1 R End 19.88 32.00 21 31 Legend: Line -Wall: At wall or opening - Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n Location - Co-ordinates in Plan View Hold-down Forces: Shear- Seismic shear overturning component, factored for ASD by 0.7, includes perforation factor Co. Dead - Dead load resisting component, factored for ASD by 0.60 Ev - Vertical seismic load effect from ASCE 7 12.4.2.2 =-0.2Sds x ASD seismic factor x unfactored D = 0.227 x factored D. Refer to Seismic Information table for more details. Cmb'd - Sum ofASO-factored overturning, dead and vertical seismic forces. May also include the uplift force t for perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down - Device used from hold-down database Cap - Allowable ASD tension load Crit. Resp. - Critical Response = Combined ASD force/Allowable ASD tension load Notes: Shear overturning force is horizontal seismic Toad effect Eh from ASCE 712.4.2. Uses load combination 8 from ASCE 7 2.4.1 = 0.6D + 0.7 (Eh - Ev). Anchor bolts must have minimum 0.229" x 3" x 3" steel plate washers, conforming to specifications in SDPWS 4.3.6.4.3 and 4.4.1.6. Refer to Shear Results table for perforation factors Co. Shearwalls does not check for either plan or vertical structural irregularities. 17 • WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 DRAG STRUT FORCES ( flexible seismic design Level 1 Line- Wall Position on Wall or Opening Location [ft] X Y Drag Strut Force [Ms] —> <_ Line 1 1-1 Left Opening 1 0.00 10.00 625 508 1-1 Right Opening 1 0.00 13.00 528 411 1-1 Left Opening 2 0.00 19.67 410 411 1-1 Right Opening 2 0.00 22.67 313 314 1-1 Left Opening 3 0.00 25.25 230 230 Line 2 2-1 Left Opening 1 20.00 12.50 563 563 2-1 Right Opening 3 20.00 23.17 217 217 Line A A-1 Left Opening 1 8.50 0.00 45 45 A-1 Right Opening 1 11.50 0.00 45 45 Line B B-1 Left Opening 1 10.42 16.00 318 263 B-1 Right Opening 1 12.08 16.00 246 191 Line C C-1 Left Opening 1 10.00 32.00 274 290 C-1 Right Opening 1 16.00 32.00 93 109 �egena: Line -Wall - Shearline and wall number Position...- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Drag strut Force - Axial force in transfer elements at openings and gaps in walls along shearline. Based on ASD factored shearline force derived from the greater of. Diaphragm force Fpx from Eqn. 12.10-1 plus 25% irregularity increase (12.3.3.4) Storey force Vx from Eqn 12.8-13 Includes perforation factor Co and redundancy factor rho. -> Due to shearline force in the west -to -east or south -to -north direction <- Due to shearline force in the east -to -west or north -to -south direction 18 r r WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 DEFLECTION ( flexible seismic design Wall, segment W Gp Dir Srf v plf b ft h ft Bending A Defl sq.in in Shear Defl in Vn Ibs Nail slip en in Defl in Hold Defl in Total Defl in Level 1 Line 1 1 1-1,1 S->N Ext 67.5 10.00 8.00 16.5 .001 .006 34 .000 .001 0.03 0.04 N->S Ext 87.8 10.00 8.00 16.5 .002 .008 44 .000 .002 0.03 0.04 1-1,2 S->N Ext 71.2 6.67 8.00 16.5 .002 .007 36 .000 .001 0.27 0.28 N->S Ext 41.0 6.67 8.00 16.5 .001 .004 20 .000 .000 0.05 0.05 1-1,3 S->N Ext 0.3 2.58 8.00 16.5 .000 .000 0 .000 .000 0.12 0.12 N->S Ext 0.0 2.58 8.00 16.5 .000 .000 0 .000 .000 0.00 0.00 Line 2 1 2-1,1 Both Ext 85.0 12.50 8.00 16.5 .001 .008 43 .000 .002 0.03 0.04 2-1,4 Both Ext 8.5 8.83 8.00 16.5 .000 .001 4 .000 .000 0.04 0.04 Line A 1 A-1,1 Both Ext 39.1 8.50 8.00 16.5 .001 .004 20 .000 .000 0.21 0.22 A-1,2 Both Ext 39.1 8.50 8.00 16.5 .001 .004 20 .000 .000 0.21 0.22 Line B 1 B-1,1 W->E 1 78.8 10.42 8.00 16.5 .001 .008 39 .000 .002 0.15 0.16 E->W 1 71.9 10.42 8.00 16.5 .001 .007 36 .000 .001 0.15 0.16 B-1,2 W->E 1 16.0 7.92 8.00 16.5 .000 .002 8 .000 .000 0.20 0.20 E->W 1 25.2 7.92 8.00 16.5 .001 .002 13 .000 .000 0.20 0.20 Line C 1 C-1,1 W->E Ext 59.5 10.00 8.00 16.5 .001 .006 30 .000 .001 0.18 0.19 E->W Ext 63.3 10.00 8.00 16.5 .001 .006 32 .000 .001 0.18 0.19 C-1,2 W->E Ext 17.4 4.00 8.00 16.5 .001 .002 9 .000 .000 0.45 0.45 E->W Ext 7.9 4.00 8.00 16.5 .000 .001 4 .000 .000 0.45 0.45 �egena: Wall, segment - Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Shearline B W Gp - Wall design group, refer to Sheathing and Framing Materials Dir - Force direction Srf - Wall surface, interior or exterior for perimeter walls, 1 or 2 for interior partitions v - Unfactored (strength -level) shear force per unit foot on wall segment = ASD force/0.70 b - Width of wall segment between openings h - Wall height Defl - Horizontal shearwall deflection due to given term: Bending = 8vh^3 / EAb; A - Cross sectional area of segment end stud(s); E - stud mod. of elasticity in Framing Materials table Shear = vh / Gt; Gt - Shear stiffness from SDPWS C4.3.3.2, value is in Sheathing Materials table Nail slip = 0.75 h x en; en - From SDPWS Table C4.2.2D; Vn - Unfactored shear force per nail along panel edge Hold - Hold-down = da x h /b; refer to Hold-down Displacement table for components of da Total defl = Deflection from bending + shear + nail slip + hold-down, as per SDPWS C4.3.2-1 19 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 HOLD-DOWN DISPLACEMENT ( flexible seismic design Wall, segment Dir Hold- down Uplift force Ibs Elong / Disp Manuf Add in in da in Slippage Pf da Ibs in Shrink da in Crush+ Extra in Total da in Hold Deft in Level 1 Line 1 1-1,1 S->N STHD10 284 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 N->S STHD10 10 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 1-1,2 S->N STHD10 -409 .117* .000 0.117 - - 0.068 0.04 0.22 0.27 N->S STHD10 -253 .000* .000 0.000 - - 0.000 0.04 0.04 0.05 1-1,3 S->N STHD10 -312 .000* .000 0.000 - - 0.000 0.04 0.04 0.12 N->S STHD10 -312 .000* .000 0.000 - - 0.000 0.00 0.00 0.00 Line 2 2-1,1 S->N STHD10 -7 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 N->S STHD10 -179 .000* .000 0.000 - - 0.000 0.04 0.04 0.03 2-1,4 S->N STHD10 -589 .000* .000 0.000 - - 0.000 0.04 0.04 0.04 N->S STHD10 -418 .000* .000 0.000 - - 0.000 0.04 0.04 0.04 Line A A-1,1 W->E STHD10 305 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 E->W STHD10 272 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 A-1,2 W->E STHD10 272 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 E->W STHD10 305 .117* .000 0.117 - - 0.068 0.04 0.22 0.21 Line B B-1,1 W->E LSTHD8 552 .089* .000 0.089 - - 0.068 0.04 0.20 0.15 E->W LSTHD8 490 .089* .000 0.089 - - 0.068 0.04 0.20 0.15 B-1,2 W->E LSTHD8 18 .089* .000 0.089 - - 0.068 0.04 0.20 0.20 E->W LSTHD8 95 .089* .000 0.089 - - 0.068 0.04 0.20 0.20 Line C C-1,1 W->E STHD10 550 .117* .000 0.117 - - 0.068 0.04 0.22 0.18 E->W STHD10 500 .117* .000 0.117 - - 0.068 0.04 0.22 0.18 C-1,2 W->E STHD10 -36 .117* .000 0.117 - - 0.068 0.04 0.22 0.45 E->W STHD10 -7 .117* .000 0.117 - - 0.068 0.04 0.22 0.45 Legena: Wall, segment - Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Shearline B Dir - Force direction Uplift fame (P) -Strength-level accumulated hold-down tension force from overtuming, dead and wind uplift da - Vertical displacements due to the following components: Elong/Disp - Elongation when slippage calculated separately; displacement when combined elongation/slippage used Manuf - Using manufacturer's value for anchor bolt length, or no bolt contribution for connector -only elongation. Unless marked with * = (ASD uplift force /ASD hold-down capacity) x max strength -level elongation or displacement * - Maximum strength -level elongation or displacement is used. May result in higher than actual displacements for lightly loaded hold-downs, causing the segment to draw less force due to lower than actual stiffness. Add - Due to longer anchor bolt length than manufacturer's value, or entire bolt length for connector -only elongation = PL / ( Ab x Es ); Ab - bolt cross -sectional area; Es = steel modulus = 29000000 psi; L = Lb - Lh; Lb = Total bolt length shown in Storey Information table; Lh = Manufacturer's anchor bolt length for given displacement/elongation from hold-down database. Slippage - Due to vertical slippage of hold-down fasteners attached to stud(s) when not combined with elongation Pf = Unfactored uplift force P / number of fasteners Bolts: = Pf/ (270, 000 D"1.5) (NDS 10.3.6) ; D = bolt diameter Nails: = en, fromSDPWS Table C4.2.2D using Pf for Vn and values for Wood Structural Panel Shrink - Wood shrinkage = 0.002 x (19% fabrication - 10% in-service moisture contents) x Ls Ls = Perp.-to-grain length between fasteners subject to shrinkage, shown in Storey Information table Crush + Extra - 0.04" wood crushing at compression end of wall segment plus extra displacement due to mis-cuts, gaps, etc. Total da = Elong/Disp + Slippage + Shrink + Crush + Extra Hold Defl - Horizontal deflection = h/b x da (4th term in the deflection equation SDPWS C4.3.2-1) h = wall height; b = segment length between openings; h,b values in Deflection table 20 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul 8, 2014 10:26:55 Level Dir Wall height ft Max dxe Line Actual Story Drift (in) Max Center dx of Mass C of M dxe C of M dx hsx ft Allowable Story Drift Delta a Ratio in Max C of M 1 N->S S->N E->W W->E 8.00 0.05 0.05 0.45 0.45 1 1 C C 0.21 0.21 1.80 1.80 10.00 10.00 16.00 16.00 0.05 0.05 0.20 0.20 0.18 0.18 0.81 0.81 8.00 2.40 0.09 0.08 0.09 0.08 0.75 0.34 0.75 0.34 ASCE 7Egn. 12.8-15:dx=dxexCd/Ie Deflection amplification factor Cd from Table 12.2-1 = 4.0 (E-W), 4.0 (N-S) Importance factor le = 1.00 Legend: Max dxe - Largest deflection for any shearline on level in this direction; refer to Deflections table Line - Shearline with largest deflection hsx - Story height in ASCE Table 12.12-1 = Height of walls plus joist depth between this level and the one above. Max dx - Largest amplified deflection on level in this direction using ASCE 7 Eq'n 12.8-15 C of M dxe - Deflection at the center of mass of this level; from interpolating deflections at adjacent shearlines. C of M dx - Amplified deflection at center of mass using Eq'n 12.8-15. Does not include differences between top and bottom diaphragm deflection. Delta a = Allowable story drift on this level from ASCE 7 Table 12.12-1 Ratio - Proportion of allowable storey drift experienced, on this level in this direction. 21 WoodWorks® Shearwalls 2014-R4-roberts.wsw Jul. 8, 2014 10:26:55 22 BERNHOFT & ASSOCIATES 702 Broadway Suite 201 Tacoma, Washington 98402 Phone (253) 274-0244 Fax (253) 627-3060 Lbernhoft@aol.com October 26, 2014 Mr. Allen Johannessen, Plans Examiner City of Tukwila Department of Community Development 6300 Southcenter Blvd, Suite #100 Tukwila, Washington 98168 (206)433-7163 RE: Correction Letter #1. Dated September 22, 2014 Development Permit Application # D14-028713 -1649 Courtyard At South Station 3900 South Center Blvd Dear Mr. Johannessen: This letter is in responses to your Correction Letter #1, dated September 22, 2014. The following responses are for each correction as follow: General Note: The plans are stamped and dated by the engineer of record, Mr. Bruce S. MacVeigh, P.E. Plan Review Notes: 1. Concrete footing support for new walls enclosing space: Revised details have been provided to reflect a continuous concrete footing and 6 inch concrete stem -wall. Because the grade is close to the finish floor level, we have made the stem -wall 8 inches above finished floor. The concrete sidewalks adjacent the foundation wall are sloped at a minimum of 2% away from the building. Roof drainage is existing and will not be changed by the new wall additions. CORRECTION bil+wo;,87 RECEIVED CITY OF TUKWILA OCT 2.8 2014 PERMIT CENTER Development Permit Application # D14-0287 Correction Letter # 1 Responses page 2 of 2. 2. Perimeter Insulation: We have added a revised detail of the foundation with the required R-10 perimeter insulation installed on the outside of the footing. The insulation is protected on the exterior w/ metal flashing. 3. Door Hardware: The hardware was noted in the Door Schedule as Corbin Russwin, Lever handle. The full description is: Corbin Russwin, CL3800 Series " Standard Duty Key -in - Lever Lockset." Model # CL3861, US 10 Satin Bronze finish, Armstrong Trim Design. Included with the letter is the Corbin-Russwin brochure. If you have any further questions, please feel free to at (253) 274-0244. Sincerely, s -,,Lsi7t- Leonard S. Bernhoft City of Tukwila Department of Community Development September 22, 2014 CHRISTINA ROBERTS PO BOX 73516 PUYALLUP, WA 98373 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D14-0287 COURTYARD AT SOUTH STATION - 3900 SOUTHCENTER BLVD Dear CHRISTINA ROBERTS, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. (BUILDING REVIEW NOTES) 1. By enclosing the existing patio to create new rooms, now considered heated spaces, the building code requires, "All exterior walls shall be supported on continuous solid or fully grouted masonry or concrete footings...." The finished grade shall be a minimum of 8" below the wood framing (sill plate), 6" from exterior sheathing. Finished grade shall show "Surface drainage shall be diverted away from the building to a storm sewer conveyance or other approved point..." The sill plate (wood framing) shall be a minimum 8" from finished grade. Show a footing at a minimum of 12" below finished grade. Footing may be located under the existing slab with a method for providing a positive footing/slab connection. Show the new footing attached to the existing foundation with method of epoxy and steel embedment. (IRC R317.1#2, 3 & 5, R401.2, R401.3, R403.1, R403.1.3.2, R403.1.4, R403.1.7.3) 2. Since this is to become new heated spaces the exterior foundation shall have a minimum of R-10 perimeter insulation. Insulation shall be installed on the exterior since installing on the inside would be difficult and require removing the slab. The insulation shall extend a minimum of 24 inches from the bottom wood sill plate to the footing to create a thermal break. Exterior exposed portion of the insulation shall be protected by flashing or other similar methods. Another option would be to do a component performance method to provide additional insulation or similar to where the building envelope shall comply with the energy code. Specify with details which method is to be installed for energy code compliance. (IBC R403.3, WSEC SECTION C402 & C402.2.6) 3. Provide door hardware specifications for accessibility in compliance with IBC 1008.1.9.1 & ANSI 404.2.6. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, -,A '-A)- Bill Rambo Permit Technician File No. D14-0287 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PLAN R �W/ROUTING SLIP PERMIT NUMBER: D14-0287 DATE: 10/28/14 PROJECT NAME: COURTYARD AT SOUTH STATION SITE ADDRESS: 3900 SOUTHCENTER BLVD Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: �4 c Building Division Public Works It--3-11J Fire Prevention Structural El Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/30/14 Structural Review Required REVIEWER'S INITIALS: DATE: u APPROVALS OR CORRECTIONS: DUE DATE: 11/27/14 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: S'f LLB fay.? )-1 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0287 DATE: 09/02/14 PROJECT NAME: COURTYARD AT SOUTH STATION SITE ADDRESS: 3900 SOUTHCENTER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 4-\LA Building Division MI Public Works 41A q,[s-(m Fire Prevention Structural cpL Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/04/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 10/02/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only G) CORRECTION LETTER MAILED: `v,2 l — 1 / Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:----� 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL _Revision submittals must be submitted person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Io/2.1J2014- ❑ Response to Incomplete Letter # Plan Check/Permit Number: D 14-0287 Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED CITY OF TUKWILA OCT 2 201k PEPMIT (*am Project Name: Courtyard at South Station Project Address: 3900 Southcenter Blvd Contact Person: Ct+ sm.) I06PLTSPhone Number: Summary of Revision: v TD u , ii2 ' 1 o -12-e1-1 vwtte.v. CAA tee. pr sv'i 0(4, ktrtA- . t' C.ert,(,.1. _ y Sheet Number(s): 54%-u.k e 4 "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: {� Entered in TRAKiT on /o/)' 1r// V \applications\forms-applications on Iine\revision submittal Created: 8-13-2004 Revised: FIRST CHOICE REMODELING Page 1 of 3 Washington State Department of Labor & Industries FIRST CHOICE REMODELING Owner or tradesperson ROBERTS, TRACY LEE Principals ROBERTS, TRACY LEE, PRESIDENT ROBERTS, CHRISTINA DEEANN, VICE PRESIDENT Doing business as FIRST CHOICE REMODELING WA UBI No. 603 172 765 Parent company FIRST CHOICE REMODELING INC PO BOX 73516 PUYALLUP, WA98373 253-507-5353 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. FIRSTCR8805B Effective — expiration 08/02/2012— 08/02/2016 Bond American Contractors Indem CO Bond account no. 100230174 Received by L&I 08/30/2013 Active. Meets current requirements. $12,000.00 Effective date 08/30/2013 Expiration date Until Canceled Platte River Ins Co Bond account no. 41152710 Received by L&I $12,000.00 Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603172765&LIC=FIRSTCR8805B&SAW= 11/14/2014